You are on page 1of 75

Outside Plant

Fiber and Copper Solutions


OmniReach FTTP Solutions
Outdoor FDH 3000..............................................................405
Sealed Fiber Distribution Closure 3000................................410
Fiber Cross Connect 3000....................................................412
Passive Optical Splitter Modules...........................................415
Wavelength Division Multiplexer Modules............................416
Multiport Service Terminal and Hardened Drop Cables........418
Access Terminals 300...........................................................425
MDU Rapid Fiber System......................................................430
Indoor FDH 3000.................................................................436
Fiber Splitter Box (FSB).........................................................438
Outdoor Fiber Distribution Terminals....................................442
MDU iFDT............................................................................448
Indoor Fiber Distribution Terminals CPE.............................450
Wall Splice Cabinet..............................................................453
RealFlex Drop Cables........................................................455

OmniReach FTTN Solutions


NCX-1000 Cabinets.............................................................460
NCX-1000s Cabinets............................................................484
ComProtect Gas Discharge Tube........................................466
KRONE Series 2 K110.........................................................469
HighBand 10......................................................................471
ComProtect Building Entrance Terminals (BET)...................478
Building Entrance Terminals.................................................475

www.adc.com

+1-952-938-8080

1-800-366-3891

403

OmniReach FTTP Solutions

Next Gen Network Solutions

The OmniReach FDH 3000 is designed to meet


and serve the distinct needs of diverse markets and
customer segments. The unique design of the FDH
3000 provides for rapid connection between fiber
optic cables and passive optical splitters in the outside
plant segment of the network, facilitating fast service
connection and reconfiguration, simplified network
installations and improved installation efficiencies in
the field.

Features and Benefits


Unique swing-out frame design
Allows for easy maintenance and access
to back of distribution panels and cables

Re-skinnable casing design


Allows replacement of cabinet shell
without break in customer service

In-hub distribution splicing option


Incorporates splicing of distribution
cables within the cabinet.

Intelligent design
Allows for standardized splitter modules
and accessories across all cabinet sizes

Three-point latch
Provides weather-tight seal

Common mini Plug-and-Play splitter


module with common output length
Allows for true Plug-and-Play functionality

Angled bulkhead panels


Eliminates 90 bends and assists technician
with routing
Integrated slack storage spools
Allows for storage of excess fiber while
providing positive bend radius control
Dust-cap friendly parking lot
Conveniently stores splitter output
ports not in service
144 terminations: up to 64 parking lots;
288 terminations: up to 72 parking lots;
432 terminations: up to 144 parking lots;
864 terminations: up to 288 parking lots

106612AE

ADCs OmniReach FTTX Solutions are the industrys


first infrastructure solutions designed from the
ground up to meet the unique requirements of
FTTX networks. Designed for operational efficiency
and scalability, OmniReach solutions simplify FTTX
network installation, maintenance and management
from the central office/headend to the outside plant.

Six-inch spacer/riser
Included with spacer/riser
Included with ground mount cabinets

6/09

Outside Plant Fiber and Copper Solutions

Outdoor FDH 3000

Pole mounting configurations


Available with extra small (24-144),
small (72-288) and medium (72-432)
termination models

Supports diverse splitter module


configurations
1x32, 2x32, 1x16, 1x64, dual 1x16, 1x8,
dual 1x8, 1x4, dual 1x4, 1x2, dual 1x2
Craft friendly splitter module design
Easy to insert and remove without affecting
adjacent splitters
Discrete ground and cable
location access
Allows for locating wires without
entry into the cabinet
Extreme temperature tubing
Improved performance at high and
low temperatures

See ADC literature #102496AE


www.adc.com

+1-952-938-8080

1-800-366-3891

404

OmniReach FTTP Solutions


Outdoor FDH 3000

Extra Small Ground Mount Cabinet (24-144 Fibers)


Catalog Number
FD3 - AC __ __ __ __ __ __ __ __ __

24 fibers

048

48 fibers

1 12 fiber

072 72 fibers

2 24 fiber

096

96 fibers

144

144 fibers

Splitter Style
P

Mini Plug-and-Play

Adapters/Connector Type
Feeder/Distribution
Cable Stub Length

Singlemode
N

SC/UPC

SC/APC

B 100 foot
Distribution Cable Configuration

Number of Splitter Modules*


0

No splitter modules

1 splitter module

2 splitter modules

Splitter Type Loaded


0

No splitters

Dual 1x8

1x32

Dual 1x16

C 1x16

1x4

1x64

2x16

2x32

Dual 1x4

1x8

All 72 fiber stubs

All 24 fiber stubs

All 48 fiber stubs

All 96 fiber stubs

All 144 fiber stubs

Feeder/Distribution Cable Type


G Single armor loose tube
J

Dielectric loose tube

Armored ribbon

Dielectric ribbon

All shaded configuration options are


lead configurations and have best
delivery dates.

*See page 420 to order individual splitters

6/09

See ADC literature #102496AE


www.adc.com

+1-952-938-8080

1-800-366-3891

405

Outside Plant Fiber and Copper Solutions

Feeder Cable Size

024

106612AE

Next Gen Network Solutions

Distribution Fiber
Panels Loaded

OmniReach FTTP Solutions


Outdoor FDH 3000

Small Ground Mount Cabinet (72-288 Fibers)


Catalog Number

Next Gen Network Solutions

FD3 - AE __ __ __ __ __ __ __ __ __

072 72 fibers

Feeder Cable Size

144 144 fibers

1 12 fiber

216 216 fibers

2 24 fiber

288 288 fibers

Adapters/Connector Type

Splitter Style

Singlemode
N

SC/UPC

SC/APC

48 fiber

Mini Plug-and-Play

Feeder/Distribution
Cable Stub Length

Number of Splitter Modules*


0

No splitter modules

1 splitter module

2 splitter modules

B 100 foot
Distribution Cable Configuration

Splitter Type Loaded

All 72 fiber stubs

All 144 fiber stubs

C All 216 stubs

No splitters

Dual 1x8

1x32

Dual 1x16

C 1x16

1x4

1x64

2x16

2x32

Dual 1x4

1x8

D All 144 fiber stubs, except 1-72


1-72 (72 fiber stubs)
73+ (144 fiber stubs)

G All 288 fiber stubs


Feeder/Distribution Cable Type
G Single armor loose tube

106612AE

*See page 420 to order individual splitters

Dielectric loose tube

Armored ribbon

Dielectric ribbon

All shaded configuration options are


lead configurations and have best
delivery dates.

6/09

Outside Plant Fiber and Copper Solutions

Distribution Fiber
Panels Loaded

See ADC literature #102496AE


www.adc.com

+1-952-938-8080

1-800-366-3891

406

OmniReach FTTP Solutions


Outdoor FDH 3000

Medium Ground Mount Cabinet (72-432 Fibers)


Catalog Number
FD3 - AG __ __ __ __ __ __ __ __ __
Feeder Cable Size

144 144 fibers

1 12 fiber

216 216 fibers

2 24 fiber

288 288 fibers

360 360 fibers

Splitter Style

432 432 fibers

P
Adapters/
Connector Type

SC/UPC

SC/APC

Mini Plug-and-Play

Feeder/Distribution
Cable Stub Length

Singlemode
N

48 fiber

B 100 foot
Distribution Cable Configuration

Number of Splitter Modules*


0

No splitter modules

1 splitter module

2 splitter modules

All 72 fiber stubs

All 144 fiber stubs

C All 216 fiber stubs


D All 144 fiber stubs, except 1-72
1-72 (72 fiber stubs)
73+ (144 fiber stubs)

Splitter Type Loaded

G All 288 fiber stubs

No splitters

Dual 1x8

1x32

Dual 1x16

1x16

1x4

G Single armor loose tube

1x64

2x16

Dielectric loose tube

2x32

Dual 1x4

Armored ribbon

1x8

Dielectric ribbon

Feeder/Distribution Cable Type

*See page 420 to order individual splitters

All shaded configuration options are


lead configurations and have best
delivery dates.

6/09

See ADC literature #102496AE


www.adc.com

+1-952-938-8080

1-800-366-3891

407

Outside Plant Fiber and Copper Solutions

072 72 fibers

106612AE

Next Gen Network Solutions

Distribution
Fiber Panels Loaded

OmniReach FTTP Solutions


Outdoor FDH 3000

Large Ground Mount Cabinet (72-864 Fibers)


Catalog Number

Next Gen Network Solutions

Feeder Cable Size

072 72 fibers

504

504 fibers

1 12 fiber

144

144 fibers

576

576 fibers

2 24 fiber

216

216 fibers

648

648 fibers

288

288 fibers

720

720 fibers

7 72 fiber

360

360 fibers

792

792 fibers

432

432 fibers

864

864 fibers

Splitter Style
P

Adapters/Connector Type

SC/UPC

SC/APC

Mini Plug-and-Play

Feeder/Distribution
Cable Stub Length

Singlemode
N

48 fiber

B 100 foot
Distribution Cable Configuration

Number of Splitter Modules*


0

No splitter modules

1 splitter module

2 splitter modules

All 72 fiber stubs

All 144 fiber stubs

C All 216 fiber stubs


D All 144 fiber stubs, except 1-72
1-72 (72 fiber stubs)
73+ (144 fiber stubs)

Splitter Type Loaded


0

No splitters

Dual 1x8

1x32

Dual 1x16

1x16

1x4

1x64

2x16

G Single armor loose tube

2x32

Dual 1x4

Dielectric loose tube

Armored ribbon

Dielectric ribbon

G All 288 fiber stubs


Feeder/Distribution Cable Type

1x8

All shaded configuration options are lead configurations


and have best delivery dates.

*See page 420 to order


individual splitters

106612AE

Distribution Fiber Panels Loaded

6/09

Outside Plant Fiber and Copper Solutions

FD3 - AJ __ __ __ __ __ __ __ __ __

See ADC literature #102496AE


www.adc.com

+1-952-938-8080

1-800-366-3891

408

OmniReach FTTP Solutions

ADCs OmniReach Sealed Fiber Distribution


Closure 3000 is a compact and flexible closure
that provides for connections between fiber optic
cables and passive optical splitters in the Outside
Plant.The closure can be mounted to support
aerial, buried and underground applications. It
offers a robust, user-friendly and cost-effective
solution for connecting feeder and distribution
cables via optical splitters in FTTP networks and
is distinctive for such applications as rural and
brownfield deployments. The unique design
of the Sealed Fiber Distribution Closure 3000
supports the needs of discrete and varied
deployment options and provides for rapid
network installation and service turn-up.

Features
Extremely Compact/High Capacity Design
Accommodates 12 feeder fibers, 96 distribution
fibers, and 3 splitter modules in a low profile
closure

Supports Diverse Splitter Module


Configurations
1x32, 2x32, 1x16, dual 1x16, 1x8, dual 1x8, dual
1x4

Rigorous Testing and Quality Standards


Meets Telcordia GR-771, GR-1209, GR-1221 and
GR-326 requirements

Craft Friendly Splitter Module Design


Easy to insert and remove without affecting
adjacent splitters

Superior Performance
Unsurpassed reliability makes it ideal for aerial,
buried and underground applications

Diverse Cable Types


Accommodates loose tube, ribbon, dielectric and
armored cable options

Environmental Protection
Thermoplastic dome provides UV stabilization,
flame retardancy, and chemical and impact
resistance

Compatible Mounting Kits (sold separately)


Allow for easy strand, pole, pedestal and hand-hole
installations

Field Proven Hermetically Sealed Closure


Provides air/water tight seal
Re-Enterable/Reusable Shell
No re-entry kits or tools required
Mini Plug-and-Play Splitter Module
Allows for true Plug-and-Play functionality

Flexible Configuration Options


Allows for splicing interior to closure or stubbed
with OSP cable
Product Dimensions
Overall enclosure length - 28" (711 mm) x Dome
Length - 24" (609 mm) x Enclosure Diameter - 9"
(228 mm)

See ADC literature #103983AE


www.adc.com

+1-952-938-8080

1-800-366-3891

409

Outside Plant Fiber and Copper Solutions

ADCs OmniReach FTTX Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.

6/09

106612AE

Next Gen Network Solutions

Sealed Fiber Distribution Closure 3000

OmniReach FTTP Solutions


Sealed Fiber Distribution Closure 3000

Next Gen Network Solutions


106612AE

6/09

Outside Plant Fiber and Copper Solutions

Ordering Information
Description

Catalog Number

Pole/ Wall Mount Kit

FD3S-ACC-P01

Strand Mount Kit

FD3S-ACC-S01

Catalog Number
FD3S- __ __ 00 __ 0 __ __ __
F1 Cable Stub Length*

F2 Fibers Loaded
24 Fibers

Pigtailed - 2m pigtails

48 Fibers

25' Cable

72 72 Fibers

100' Cable

24
48
96

* Standard 12 fiber size

96 Fibers*

* Only available for stubbed option

Input Type

Connector Type
N

SCUPC

SCAPC

Plug-and-Play

No input/no splitter chassis

F2 Cable Stub Length


Stub Type*
T

Ribbon Dielectric

Ribbon Armored

Single Armored Loose Tube

Dielectric Loose Tube

Stranded Pigtails

Ribbon Pigtails

Pigtailed - 2m pigtails

25' Cable

* Input and output stub


Catalog Number
FPS-MPP 2 __ __ __
Output Connector Style

Splitter Type Loaded


A

1x32 standard

SC ultra polish

1x16 standard

SC angled polish

2x32 standard power

1x8 standard

Dual 1x8 standard

Dual 1x16 standard

1x4 standard

2x16 standard

Dual 2x16 standard

Dual 1x4 standard

Input Connector Style


N

SC ultra polish

SC angled polish

W 1x2 standard
See ADC literature #103983AE.
www.adc.com

+1-952-938-8080

1-800-366-3891

410

OmniReach FTTP Solutions

6/09

106612AE

ADCs OmniReach FTTX Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.
The OmniReach Fiber Cross Connect 3000 is
designed to meet and serve the distinct needs
of diverse markets and customer segments. The
unique design of the Fiber Cross Connect 3000
provides for a rapid connection, facilitating fast
service connection and reconfiguration, simplified
network installations and improved installation
efficiencies in the field.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Fiber Cross Connect 3000

Unique Design to Meet Diverse


Customer Requirements
Craft Friendly to support both low and highdensity applications, different network system
designs, and diverse installation environments
Flexible and Modular
Standardized modules and accessories for all Fiber
Cross Connect 3000 cabinets
Easy to Order
Streamlined configurations simplify the
ordering process
Incorporates ADC Quality and Innovation
ADC is a high quality, industry-leading brand you
can rely on to future-proof your network, with a
complete portfolio of FTTX products and services
to ensure seamless deployment and maintenance
over the life of the network
The Fiber Cross Connect 3000 incorporates four
time-tested elements that have long impacted
reliability, flexibility and operational costs within
the central office/headend:
Bend radius protection
Intuitive cable routing
Easy fiber/connector access
Physical protection

See ADC literature #104002AE


www.adc.com

+1-952-938-8080

1-800-366-3891

411

OmniReach FTTP Solutions


Fiber Cross Connect 3000

Next Gen Network Solutions

Intelligent design
Allows for standardized modules and
accessories across all cabinet sizes
Unique swing-out frame design
Allows for easy maintenance and access
to back of modules and cables
Features discrete ground and cable
location access
Allows for locating wires without entry into
the cabinets
Integrated slack storage spools
Allows for storage of excess fiber while
providing positive bend radius control
Angled bulkhead panels
Eliminates 90 bends and assists technician
with routing
Pole mounting option
Available with small and medium
termination models
Three-point latch
Provides weather-tight seal
Six-inch pad mount skirt
Included with all cabinets
Hand hole options
Available in polymer-concrete
NEMA-4 Design
Provides heavy duty protection from wind,
rain and other contaminants
Accessible with standard 216B tool
Offers flexible security options, including
pad lock provisions

106612AE

Three cabinet sizes


Small (72-288 fibers)
Medium (72-432 fibers)
Large (72-864 fibers)

6/09

Outside Plant Fiber and Copper Solutions

Features and Benefits

See ADC literature #104002AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

412

OmniReach FTTP Solutions


Fiber Cross Connect 3000

Catalog Number
F3X- __ __ __ __ __ __ __ __ __ __ __
Cabinet Size

6/09

106612AE

Cable 6 Type

288 Cabinet 30"(H) x 27"(W) x 18"(D)

No Cable

G 432 Cabinet 41"(H) x 27"(W) x 18"(D)

72 Fiber Distribution

864 Cabinet 48"(H) x 46"(W) x 22"(D)

Distribution Fiber Count


Singlemode
072 72 Fiber Distribution
216 Fiber Distribution

288

288 Fiber Distribution

360

360 Fiber Distribution

432

432 Fiber Distribution

504

504 Fiber Distribution

576

576 Fiber Distribution

648

648 Fiber Distribution

720

720 Fiber Distribution


864 Fiber Distribution

Adapter Style
N

SC/UPC

SC/APC

216 Fiber Distribution

288 Fiber Distribution

No Cable

72 Fiber Distribution

144 Fiber Distribution

216 Fiber Distribution

288 Fiber Distribution

Cable 4 type

792 792 Fiber Distribution


864

144 Fiber Distribution

Cable 5 Type

144 144 Fiber Distribution


216

B
D

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

No Cable

72 Fiber Distribution

144 Fiber Distribution

216 Fiber Distribution

288 Fiber Distribution

Cable 3 Type

Cable Configuration

No Cable

Dielectric Loose Tube

A 72 Fiber Distribution

Single Armor Loose Tube

B 144 Fiber Distribution

Dielectric Ribbon

D 216 Fiber Distribution

Single Armor Ribbon

288 Fiber Distribution

Cable Length
B

100 foot

300 foot

500 foot

Cable 2 Type
O

No Cable

A 72 Fiber Distribution

Cable 1 type

B 144 Fiber Distribution

A 72 Fiber Distribution

D 216 Fiber Distribution

B 144 Fiber Distribution

288 Fiber Distribution

D 216 Fiber Distribution


E

288 Fiber Distribution

See ADC literature #104002AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

413

OmniReach FTTP Solutions


Passive Optical Splitter Modules

Mini Plug-and-Play Splitter Modules

Next Gen Network Solutions


106612AE

6/09

Outside Plant Fiber and Copper Solutions

The FDH 3000 utilizes a Mini Plug-and-Play Splitter


Module which is common to all of the cabinets
and features a common output length. This
module allows for true Plug-and-Play functionality.
Standardized splitter modules for
all cabinet sizes
Features bend-optimized fiber and ruggedized
extreme temperature cabling rated for material
handling in cold temperatures and superior
loss performance at 1490 and 1550 nm
wavelengths
Rated from -55 C to 85 C
Allows pass-through of up to 2 fibers per
splitter set
Splitters are easy to insert and remove without
affecting adjacent splitters
Reversible dust cap makes test and
turn-up easy
Wide band pass 1260-1635 nm to ensure
optical performance for all applications

Feeder Pass-Thru Feature

Splitter types supported with specifications


Standard

Max Loss*

Typical Loss*

Uniformity

Return Loss

Directivity

PDL

3.7 dB

3.1 dB

0.8 dB

55 dB

55 dB

0.3 dB

1x4

7.2 dB

6.2 dB

0.8 dB

55 dB

60 dB

0.2 dB

1x8

10.7 dB

9.8 dB

1.0 dB

55 dB

60 dB

0.2 dB

1x16

13.5 dB

13.2 dB

1.5 dB

55 dB

60 dB

0.3 dB

1x32

16.7 dB

16.5 dB

1.5 dB

55 dB

60 dB

0.3 dB

1x64

20.4 dB

19.7 dB

2.0 dB

55 dB

60 dB

0.4 dB

2x16

14.7 dB

13.0 dB

2.0 dB

55 dB

60 dB

0.4 dB

2x32

17.9 dB

16.3 dB

2.5 dB

55 dB

60 dB

0.4 dB

1x2

* Does not include connector loss


Catalog Number

Output Connector Style

FPS-MPP 1 __ __ __

Splitter Type

SC ultra polish

SC angled polish

1x32

Single 1x64

1x16

1x4

2x32

2x16

1x8

Dual 1x4

SC ultra polish

Dual 1x8

1x2

SC angled polish

Dual 1x16

Dual 1x2

Input Connector Style

All shaded configuration options are


lead configurations and have best
delivery dates.
Additional options are available,
please contact the ADC Technical
Assistance Center.
See ADC literature #102902AE

www.adc.com

+1-952-938-8080

1-800-366-3891

414

OmniReach FTTP Solutions

Installed in central office/headend fiber panels


or frames, or in outside plant enclosures,
wavelength division multiplexers (WDMs) enable
carriers to mux and demux optical signals to
combine analog or digital video with voice and
data. There are flexibility advantages for placing
the WDM inside the fiber distribution frame
lineup as opposed to placing it beside the optical
line terminal (OLT) equipment.

Outside Plant Fiber and Copper Solutions

ADCs OmniReach FTTP Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTP networks. Designed for
operational efficiency and scalability, ADCs
OmniReach solutions simplify FTTP network
installation, maintenance, and management from
the central office/headend to the outside plant.

FDF/standard style

Features
Integrated into traditional ADC fiber
management systems
Qualified to GR-1209 and GR-1221
Rugged package protects delicate splitters
from installer handling or in harsh
environments

LGX style

Industry-leading low loss


Terminated with GR-326 certified connectors
Adapter port modules in a variety of package
styles allow adaptation to many applications
Removable retainers allow access to rear ports
for cleaning
Colored retainers and designation labeling
help technicians distinguish between ports
LGX is a registered trademark of Furukawa Electric
North America, Inc.

MicroVAM style

6/09

106612AE

Next Gen Network Solutions

Wavelength Division Multiplexer Modules

9" LGX style

See ADC literature #103166AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

415

OmniReach FTTP Solutions


Wavelength Division Multiplexer Modules
Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

177.8 x 482.6/584.2 x 279.4 mm


(7" x 19/23" x 11")

FVM-VLM19X700-W

88.9 x 476.5 x 279.4 mm


(3.50" x 18.76" x 11")

FVM-LGX19X350-W

3.5" horizontal mount; accommodates


up to 4 modules

Catalog Number
VPM - ___ ___ ___ ___ ___

___
Number of Circuits

Package Style
A

FDF/standard style

LGX style

2 Two

MicroVam style

9" LGX style

Six*

*Package Style M only


Input 2 Connector Style

Wavelength Plan
V

One

1310/1490 nm and 1550 nm

Output (Common)
Connector Style

SC/UPC

SC/APC

Input 1 Connector Style

SC/UPC

SC/UPC

SC/APC

SC/APC

106612AE

Next Gen Network Solutions

7" vertical mount; accommodates


up to 12 modules

6/09

Outside Plant Fiber and Copper Solutions

VAMs unloaded chassis

See ADC literature #103166AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

416

OmniReach FTTP Solutions


ADCs OmniReach FTTX Solutions are the
industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.

Outside Plant Fiber and Copper Solutions

The OmniReach Multiport Service Terminal (MST)


incorporates hardened connector technology
that is designed to withstand the rugged outside
plant environment. These uniquely designed
hardened connectors are factory-terminated and
environmentally sealed for use in optical drop
cable deployments.
ADCs OmniReach Hardened Cables are
environmentally robust to provide a reliable
interface for fiber drop cables in the outside plant
environment. At the same time, the hardened
connector approach dramatically reduces
splicing labor requirements. The rugged optical
connector is hardened to protect against extreme
temperature, moisture, UV, chemical exposure
and other harsh conditions typically found in the
outside plant.

Benefits:
Robust environmental performance:
Withstands extremes in temperature and
conditions
Technician-friendly features: Intuitive design
for ease of use
Decreased installation and incremental
maintenance hours: Significant savings
Protection: Self-contained unit features
hardened connectors for superior durability
and reliability in the drop segment of the
network
Compatibility: Interoperability with industry
standard hardened connectors

6/09

106612AE

Next Gen Network Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

417

OmniReach FTTP Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables


Features:

Next Gen Network Solutions

Tested to meet GR-326, GR-771 and GR3120 standards for robust environmental
performance
Connection interface utilize factory terminated
high-performance SC/APC connectors
Hardened adapters provide environmentally
secure interface for fiber drops
Factory sealed enclosure provides resistance
to environment
Improved structural design withstands stress
and impact
Re-enterable enclosure allows for easy
technician access for repairs
Superior cable and fiber management ensures
proper bend radius, prevents cable strain and
minimizes kinking
Available with dielectric and armored input
stub cables in standard lengths
Compatible with OptiTap connector system
User-friendly packaging allows for easy
un-spooling

MST Ordering Information


Catalog Number
MST - __ __ M H 0 0 - __ __ __ __ __ U

Cable Stub Length

Terminal Model

0050

02 2-Port
06

6-Port

08

8-Port

50 Feet

0100 100 Feet

04 4-Port

106612AE

Flexible mounting options including pole,


pedestal, hand hole or strand to support both
aerial and below grade applications

6/09

Outside Plant Fiber and Copper Solutions

Available in 2, 4, 6, and 8 port configurations

0250 250 Feet


0500

500 Feet

0750 750 Feet


1000 1000 Feet

Cable Type

1500 1500 Feet

Dielectric Flat Loose Tube

Locatable Flat Loose Tube

C Armored Round Loose Tube

2000

2000 Feet

Standard lengths shown.

OptiTap is a registered trademark of Corning Cable Systems Brands, Inc.

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

418

OmniReach FTTP Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables

MST Ordering Information


Catalog Number

Cable Stub Length

Terminal Model
06

6-Port

08

8-Port

Outside Plant Fiber and Copper Solutions

MST - __ __ R H 0 0 - __ __ __ __ __ U

0050

50 Feet

0100 100 Feet


0200 200 Feet

12 12-Port

0500

500 Feet

0750 750 Feet

Cable Type

1000 1000 Feet

Dielectric Flat Loose Tube

1500 1500 Feet

Locatable Flat Loose Tube

2000

2000 Feet

Standard lengths shown.

6/09

106612AE

Next Gen Network Solutions

The 4x3 terminal body is optimized form factor


below grade enclosures and hand holes. The 12 port
configuration provides superior technician access by
providing three rows of four hardened adapters.

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

419

OmniReach FTTP Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables

Next Gen Network Solutions


106612AE

ADCs OmniReach MST products have a versatile


mounting scheme, allowing all versions of the
product to be mounted on a pole, in a pedestal,
in a hand hole or to a strand in support of both
aerial and below grade applications. All mounting
solutions provide a robust, user friendly and costeffective option for delivering fiber optic service
drops in FTTX deployments and allow for efficient
craft access to connections.
Pole Mount

Pedestal Mount

Hand Hole Mount

Strand Mount

ADCs OmniReach MST Universal Mounting


Brackets provide a universal mounting solution
to support the versatile MST mounting options
including pole, pedestal, hand hole and strand
applications. These brackets provide for simple,
secure, economical and rapid terminal installation
in any FTTP deployment.

Features:
Single bracket compatibility for all
mounting schemes
Designed to save time and cost, reduce
complexity and necessary logistics, and
streamline process of mounting MST
Snap-in/snap-out installation easily engages/
disengages MST with an audible snap
engagement and single latch release
making MST readily available for drop cable
connections or re-connections
Rigid plastic structure using same materials
as MST to withstand environmental
exposures, including contracting/expanding
temperatures
Bracket mounted separately minimizing risk
of damage to MST
Eliminates need for additional bracket
inventory and materials in field
Stands up under high vibration or stress
created by cables placed in the MST

6/09

Outside Plant Fiber and Copper Solutions

MST Universal Mounting Brackets

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

420

OmniReach FTTP Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables


MST Mounting Accessories
Ordering Information
Description

Catalog Number
MST-UMB-0204
MST-UMB-0608

4x3 Terminal in all Configurations.

MST-UMB-4312

Strand Mount Bracket

MST-ACC-M02

ADC 8" Pedestals1


with Vented Cover

MST-ACC-W10

with Bell Jar Cover

MST-ACC-Y10

with Vented Cover and Grounding

MST-ACC-W10G

with Bell Jar Cover and Grounding

MST-ACC-Y10G

Hand Hole Kits


17"x30" kit with swing arm

MST-ACH-C730Y300

24"x36" kit with swing arm

MST-ACH-C436Y300

1
Industry standard pedestals with mounting hardware also available. Please contact the ADC Technical Assistance
Center at 1-800-366-3891 for more information.

Pole Mount
Installation

Below Grade
Installation

Aerial Mount
Installation

6/09

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

421

Outside Plant Fiber and Copper Solutions

2- and 4-port dielectric cable stub MST


6- and 8-port dielectric cable stub MST / 2- and 4-port armored stub MST

106612AE

Next Gen Network Solutions

Universal Mounting Bracket

OmniReach FTTP Solutions

Next Gen Network Solutions

Benefits

Single-fiber, single-mode hardened connector


SC APC drop cable assemblies
Available with one or both ends connectorized

Provide the ultimate Plug-and-Play solution


for durable and reliable service connection in the
outside plant/drop segment of the network

Available standard lengths from 75 to


2000ft increments (longer assemblies
available upon request)

Technician-friendly to greatly simplify installation


and maintenance by minimizing splicing required
on the distribution side of the network

Environmentally sealed connector

Cost effective solutions that provide for lower


overall installed costs throughout the FTTX network

Easy connection to hardened adapters on


terminals or closures
Arrow on hardened connector shell ensures
precise alignment of connector into optical port.
Connector can be pulled through 1.25-inch
conduit
Pulling eye on connector cap is designed for
100 lb. maximum pulling tension
Drop cable fully tested to GR-20 and designed to
GR-3120

Hardened Drop Cable Ordering Information


Catalog Number
FHD - H __ 1 __ - 0 __ __ __ __ __
Connector 1
H

Unit of Measure

Hardened ASC

Connector 2
H

Hardened ASC

Stub end/none

XXXX

Dielectric/Flat

Locatable/Flat

Length

Standard Lengths (all in feet):


Single Ended Cables

Cable Type
A

Feet

Length

75 100 150 200


250 300 400 500
750 1000 1500 2000
Double Ended Cables

106612AE

Features

105
165
300

6/09

Outside Plant Fiber and Copper Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables

120
180
350

135
200

150
250

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

422

OmniReach FTTP Solutions

Multiport Service Terminal (MST) and Hardened Drop Cables


Hybrid Cables
As the leader in flexible, value added cable management solutions, ADC allows customers
to connect the Optical Network Terminal (ONT) to the drop point in multiple ways:
OmniReach hardened connectors

6/09

106612AE

Standard SC adapters
Features

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Spliced cables

Standard connector on one end, stub or


hardened connector on other end
18" 2.0 mm breakout from flat drop cable
Dielectric toneable cable type
Ability to be pulled through smaller conduit
sizes (1/2", 3/4")
Eliminates need for purchased pigtails and
splice tray at ONT

Hardened Connector Test Kit


ADCs OmniReach Hardened Connector Test Kit
is a durable, waterproof and portable bag that
houses all the testing and maintenance tools
needed for a hardened connector architecture.
This kit includes a heavy duty water-resistant
carrying case with individual pockets for
organizing the test cables, adapters, cleaning kit,
technical cleaning and turn-up documentation
and the product reference sheet. The rugged case
also allows for additional space for carrying other
related items and/or test equipment required by
the technician.

Features
Durable, waterproof, and portable bag houses
all testing and maintenance tools needed for a
hardened connector architecture
Test cables and adapters provide transition from
hardened to standard SC connector interfaces
Cleaning kit for the hardened drop cable/adapter
includes a cleaning cassette and 50 hardened
adapter cleaning swabs

Simplified turn-up and cleaning instructions


One-stop test resource for technicians
supporting hardened connector architectures
User friendly packaging to accommodate
additional space/compartments for key testing
equipment (i.e. OTDRs, power meters) to support
overall technician needs

Quick reference ordering guide is included to


replenish kit consumables

See ADC literature #106021AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

423

OmniReach FTTP Solutions

OmniReach AT 300 Access Terminal Solutions are


designed to meet and serve the wide range of
customer requirements, providing a robust, user
friendly and cost-effective platform for delivering
fiber optic service drops in FTTX deployment.

Benefits
Intelligent Designsmart cable management
system maximizes performance, prevents
damage and allows for future growth.
PracticalMatches optical node terminal
deployment to service request.
Future-ProofSupports efficient service
deployment, management and technology
upgrades.
Flexibleprovides for a wide number of
service applications

106612AE

Next Gen Network Solutions

ADCs OmniReach FTTX Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.

6/09

Outside Plant Fiber and Copper Solutions

Access Terminals 300

See ADC literature #103800AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

424

OmniReach FTTP Solutions


Access Terminals 300

8" Non-Metallic Pedestal


Features

Includes a winter drop access door


Provides intuitive, flexible fiber cable
managementmeeting all bend radius
specifications
Includes grounding for armored cables and
towable conduit

Removing the cover is quick and easya quarter


turn with a can wrench releases the top for
immediate access. The cover is self locking
Cover can be ordered with either bell jar or
condensation venting options
Meets GR-13 and NEMA 6 requirements
Includes a barrier plate which provides protection
against ground moisture and rodents

Ordering Information
Description

Catalog Number

AT 300 8" Non-Metallic Pedestals


Pass-through spliced drop only

FAT-YNB0012Y0-000G

2 ADC hardened adapter drops wtih pigtails. HS fusion splice

FAT-YNA1200Y0-H02G

4 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-YNA1200Y0-H04G

6 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-YNA1200Y0-H06G

AT 300 8" MST Mounting Pedestal


8" Pedestal with bell jar cover

MST-ACC-Y10

8" Pedestal with bell jar cover with grounding

MST-ACC-Y10G

Additional configurations available. May require minimum order quantity.

6/09

See ADC literature #103800AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

425

Outside Plant Fiber and Copper Solutions

The unique, unobtrusive design provides an


attractive profile for residential deployments

Uses standard 216B tools

106612AE

Next Gen Network Solutions

Molded from polypropylene material which is


lightweight and non-corrosive

OmniReach FTTP Solutions


Access Terminals 300

11" Non-Metallic Pedestal

Next Gen Network Solutions


106612AE

6/09

Outside Plant Fiber and Copper Solutions

Features
Molded from polypropylene material which is
lightweight and non-corrosive
The unique, unobtrusive design provides and
attractive profile for residential deployments
Includes a winter drop access door and drop
wire channel standard
Provides intuitive, flexible fiber cable
managementmeeting all bend radius
specifications
Includes grounding for armored cables and
towable conduit
Uses standard 216B tools
Removing the cover is quick and easya
quarter turn with a can wrench releases the
top for immediate access. The cover is self
locking
Cover can be ordered with either bell jar or
condensation venting options
Meets GR-13 and NEMA 6 requirements
Includes a barrier plate which provides
protection against ground moisture and
rodents
Split base

Ordering Information
Description

Catalog Number

AT 300 11" Non-Metallic Pedestals


Pass-through spliced drop only

FAT-ZNB0012Y0-000G

4 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-ZNA1200Y0-H04G

6 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-ZNA1200Y0-H06G

8 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-ZNA1200Y0-H08G

AT 300 11" MST Mounting Pedestal


11" MST Mounting Pedestal

MST-ACC-Z11

11" MST Mounting Pedestal with grounding

MST-ACC-Z11G

*Additional configurations available. May require minimum order quantity.

See ADC literature #103800AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

426

OmniReach FTTP Solutions


BD4 Metallic Pedestals

Industry standard BD4 8" metallic


pedestal provides access for splice
connectorized drops

Outside Plant Fiber and Copper Solutions

Value Added Features


ADC cable management
Pedestal meets industry standards
Drop cable clamp
Grounding features
User friendly for technical field
Flexible management of buffer tubes
Easy to use strength member clamp

8.62

8.53

Pedestal Cover

106612AE

Next Gen Network Solutions

Features

28.0
Above Grade
Level

37.02

6/09

Security
Fastener

Base
9.0
Grade Level

See ADC literature #103800AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

427

OmniReach FTTP Solutions


BD4 Metallic Pedestals

Ordering Information
Description

Catalog Number

Next Gen Network Solutions

FAT-4NB0012Y0-000G

4 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-4NA1200Y0-H04G

6 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-4NA1200Y0-H06G

8 ADC hardened adapter drops with pigtails. HS fusion splice

FAT-4NA1200Y0-H08G

*Additional configurations available. May require minimum order quantity.

Accessories
Ordering Information
Description

Catalog Number

Splice trays
12 fiber AT 300 splice tray

FAT-FST-HS01

24 fiber AT 300 splice tray*

FAT-FST-HS02

Sealing kits
8" pedestal sealing kit

FAT-ACC-SLKT1

12" pedestal sealing kit

FAT-ACC-SLKT2

Mounting stakes
ADC non-metallic 32" mounting stake

MST-ACC-Y32S

ProForm/BD 42" mounting stake

MST-ACC-J42S

ProForm/BD 32" mounting stake

MST-ACC-J32S

Replacement Moisture Barrier Plate Kit**


8" ADC non-metallic

FAT-MBP-Y

11" ADC non-metallic

FAT-MBP-Z

8" ProForm

FAT-MBP-R

10" ProForm

FAT-MBP-J

*24 fiber splices with use of 250 micronfibers


**Configured for use with ADC AT300 cable management systems

106612AE

Pass-through spliced drop only

6/09

Outside Plant Fiber and Copper Solutions

AT 300 BD4 Metallic Pedestal

See ADC literature #103800AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

428

OmniReach FTTP Solutions

6/09

106612AE

ADCs new OmniReach Rapid Fiber System is


designed to eliminate the unique challenges
posed by todays Multiple Dwelling Unit (MDU)
buildings, when deploying FTTX networks. MDU
buildings present service providers with diverse
challenges such as varying cable pathways
and distances between logical distribution
points, demanding installation schedules and
increased quality risks due to splicing. ADCs
Rapid Fiber system is designed specifically to
assist service providers when deploying MDU
optical fiber distribution networks for a variety of
architecturesand do so in less time and with
less total cost on a consistent, high quality basis
for every building.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

MDU Rapid Fiber System

ADCs Rapid Fiber system is the ultimate plugand-play solution for delivering fast, durable and
reliable service for mid- and high-rise MDUs and
is available in multiple configurations to meet
the unique requirements of each building.
The OmniReach Rapid Fiber system for MDU
applications includes the following
Fiber-to-the-Premises (FTTP) products:
Rapid Indoor Fiber Distribution Hub 3000i
Rapid MDU Collector Enclosure
Rapid Fiber Distribution Terminal
ADCs Rapid Fiber system provides for quick and
easy deployment with increased reliability which
allows for fast service turn-up, improved network
reach and lower overall network operating and
maintenance costs.

Features and Benefits


Reduces overall lead-time and installation
process
Innovative RapidReel technology
Provides flexibility in deployment with various
size terminals, cable types and standard cable
lengths
Utilizes Reduced Bend Radius Fiber
Miniaturized cable requires less space for slack
storage of excess fiber cable
Simplifies ordering and inventory

See ADC literature #105783AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

429

OmniReach FTTP Solutions

Features and Benefits

Rapid Indoor FDH


with built-in MT

Configurations include spliced, stubbed and


MT connectors
All configurations can be either wall or rack
mounted with the hardware provided
The MT connector configuration eliminates
the need for MDU Collector Enclosure
Traditional swing-frame design allows superior
rear access
Designed to meet NEMA-12 requirements

Rapid Indoor FDH


with easy access to
built-in MT panel

106612AE

Next Gen Network Solutions

ADCs OmniReach Rapid iFDH is an inside plant


cabinet which serves as the main distribution
and cross-connect point for the MDU. It supports
integrated splicing, stubbed cables or integrated
MT connectors. The Rapid iFDH is available in a
variety of fiber counts accommodating up to 432
living units from a single cabinet.

6/09

Outside Plant Fiber and Copper Solutions

MDU Rapid Fiber System

See ADC literature #105783AE


www.adc.com

+1-952-938-8080

1-800-366-3891

430

OmniReach FTTP Solutions


MDU Rapid Fiber System

Catalog Number
FD3-M __ __ __ __ __ __ __ __ __ __ __

6/09

106612AE

Feeder Fiber Count

Indoor 72 cabinet

12 fibers

Indoor 288 cabinet

24 fibers

Indoor 432 cabinet

48 fibers

72 fibers

Distribution Fiber Count

Feeder Cable Length

072

72 fiber distribution

144

144 fiber distribution

100' stub top entry

216

216 fiber distribution

Spliced input

288

288 fiber distribution

360

360 fiber distribution

432

432 fiber distribution

Feeder Cable Type

Adapter Style

Indoor/outdoor ribbon stub

Riser ribbon stub

Indoor/outdoor loose tube stub

SC/APC

Riser loose tube stub

SC/UPC

Stranded pigtails (splice)

Ribbon pigtails (splice)

No. Splitter Modules


0

No splitters

1 splitter

2
4

Distribution Cable Configuration


A

All 72 fiber stubs

2 splitters

All 144 fiber stubs

4 splitters

Highest stub count possible

All 144 fiber stubs, except first 1-72

Spliced distribution

MT patch

Splitter Type
0

No splitters

1x32 standard

1x16 standard

2x32 standard-power

1x8 standard

Distribution Stub Length


A

50' stub

No stub

Dual 1x8 standard

Dual 1x16 standard

Riser ribbon stub

1x4 standard

Riser loose tube stub

2x16 standard

Loose tube pigtails

Dual 1x4 standard

Ribbon pigtails

MT connectors

Distribution Cable Type

See ADC literature #105783AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

431

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Cabinet Size

OmniReach FTTP Solutions

Next Gen Network Solutions

Features and Benefits

Rapid MDU Collector Enclosure


(open)

Accommodates up to 6 MT mated pairs


Ships with 72-fiber riser ribbon stubs
Slotted foam grommet provides easy drop
installs while maintaining seal
Same mounting pattern as the Fiber
Distribution Terminal

Catalog Number
MCA-S __ __ __ 1 __ __ __
Fiber Count
60

Enclosure Type

60 fiber

6 MT indoor enclosure

72 72 fiber
Stubbed End Configuration
Cable Type

Indoor/outdoor ribbon

Riser ribbon

Plenum ribbon

Enclosure End Configuration

Length
A

50'

100'

Stub (no connector)

12F MT's with enclosure

Stub (no connector)

106612AE

ADCs OmniReach Rapid MDU Collector


Enclosure serves as zoned, intermediate
distribution points within the MDU for designs
using MT cable stubs instead of splices. Each
enclosure is wall mounted within the MDU
building and accommodates up to six MT pairs
and ships with 72-fiber riser ribbon stubs.

6/09

Outside Plant Fiber and Copper Solutions

MDU Rapid Fiber System

See ADC literature #105783AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

432

OmniReach FTTP Solutions


ADCs OmniReach Rapid Fiber Distribution
Terminal serves as the final distribution point
between the iFDH and living unit. It eliminates the
need for splice cases and separate cable assemblies
by integrating the patent-pending RapidReel
cable payout system. The RapidReel system
includes a built-in reel enabling quick payoff of up
to 500 feet of MT stubbed 12 or 24 count optical
fiber cable from a single 6"x9" wall box. The MT
stub is pulled for installation into either the MDU
Collector Enclosure or directly to an iFDH equipped
with an MT patch panel. After installation the
spool flanges can be broken away and the wall box
is secured to the wall safely storing the remaining
slack cable. Use of factory terminated and tested
MT connectors instead of splicing provide a Plugand-Play environment that reduces labor costs and
speeds project completion.

Outside Plant Fiber and Copper Solutions

Rapid FDT using slider adapter packs

Rapid FDT with built-in spool

Features and Benefits


Built-in spool allows for easy payoff of MT stub
RapidReel technology allows the cable to payoff
from the complete stubbed enclosure assembly
Patented break-away spool flanges reduce slack
storage size to within the enclosures footprint
Designed for indoor and outdoor use
Utilizes Reduced Bend Radius Fiber
Designed to meet NEMA-4 and NEMA 12
requirements

6/09

106612AE

Next Gen Network Solutions

MDU Rapid Fiber System

See ADC literature #105783AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

433

OmniReach FTTP Solutions


MDU Rapid Fiber System

Catalog Number
RDT- __ __ ___ __ __ __ __ ____ __ __
Stubbed End Configuration

Standard

Enclosure Type
J

24 fiber

MT connectors

No connectors

Enclosure End Configuration

Fiber Count
12 12
24 24

2 mm fanouts

No connectors

Cable Length

Connector Type
J

SC/APC

Splice Trays
0

No tray

Heat shrink fusion

Mechanical/ribbon

100

100'

200

200'

300

300'

400

400'

500

500'

Cable Type

Customer Side Pigtails


P

3 mm, 12 fiber fanouts


with 2 mm outputs

No pigtails, no splice trays

3 mm loose tube riser


(zipcord for 24 fiber)

3 mm loose tube plenum


(zipcord for 24 fiber)

106612AE

Next Gen Network Solutions

6/09

Outside Plant Fiber and Copper Solutions

Configuration

See ADC literature #105783AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

434

OmniReach FTTP Solutions

6/09

106612AE

ADCs OmniReach Indoor Fiber Distribution Hub


3000 series cabinets (FDH 3000i) are designed
to organize and administer fiber optic cables
and passive optical splitters in an inside plant
environment typically found at the Multiple
Dwelling Unit (MDU). These cabinets are used
to connect feeder and distribution cables via
optical splitters in a Fiber-to-the-Premises (FTTP)
network application. This cabinet provides a vital
cross-connect/interconnect interface for optical
transmission signals at the MDU.
The FDH hardware and components support
the architectural flexibility of FTTP allowing fast
and reliable interconnection between equipment
and cables. The cabinet provides mechanical
protection for cables, splices, connectors and
passive optical splitters. In addition the product
is designed to accommodate a range of fiber
counts and support factory installation of pigtails,
fanouts, and splitters.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Indoor FDH 3000

The FDH cabinet is designed for front access via a


swing frame configuration. The unit accommodates
either riser or indoor/outdoor cables via sealed
grommet entry. Cables are secured with standard
grip clamps to provide required pull out strength.
The cabinet provides grounding for metallic
members and for the cabinet.

Features
Integrated splice tray offers flexible splice
management for individual or full splice capacity

Identification and labeling assure product


traceability and ease of identification

Sealed cabinets protect fibers from dust, water


spray, insects and other contaminants

Designed to NEMA-12

Accommodates high-density pre-terminated


configurations, typically 72, 144, 288 or
432fibers
Accommodates high-density modular splitter
options; 1x16, 1x32, dual 1x8, dual 1x4
Utilizes mini Plug-and-Play splitter modules that
allows for true Plug-and-Play functionality; allows
for standardized splitter modules and accessories
across all cabinet sizes
Unique swing out frame design that allows for
easy maintenance and access to back of modules
and cables

Designed to GR-3123
Complete fiber management allows for flexible
re-arrangement
Cable management and routing limits bend radius
and adds strain relief
216-Tool (can wrench), key lock or padlock offers
flexible security options
Traditional swing frame design allows for superior
rear access
Rack, wall or pad mountable
Bend insensitive fiber on splitter outputs
True Plug-and-Play splitter technology

See ADC literature #104470AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

435

OmniReach FTTP Solutions


Indoor FDH 3000

Catalog Number
FD3-M __ __ __ __ __ __ __ __ __ __ __ __ __

Next Gen Network Solutions


106612AE

Feeder Fiber Count

Indoor 72 Cabinet

12 Fibers

Indoor 288 Cabinet

24 Fibers

Indoor 432 Cabinet

48 Fibers

Distribution Fiber Count

Feeder Cable Length

072 72 Fiber Count

100 foot Stub

144 144 Fiber Count

Spliced Input

216

216 Fiber Count

288

288 Fiber Count

360

360 Fiber Count

Feeder Cable Type

432 432 Fiber Count


Adapter Style
J

SC/APC

I/O Ribbon

I/O Loose Tube

Riser Loose Tube

Stranded Pigtails

Ribbon Pigtails

Distribution Cable Configuration

No. Splitter Modules


0

No Splitters

All 72 Fiber Stubs

1 Splitter

All 144 Fiber Stubs

2 Splitters

Highest Stub Possible

4 Splitters

All 144 Fiber Stubs, except


first 1-72

Spliced Distribution

Splitter Type
0

No Splitters

1x32 standard

1x16 standard

50 foot Stub

2x32 standard - power

No Stub

1x8 standard

Dual 1x8 standard

Dual 1x16 standard

Riser Ribbon Stub

1x4 standard

Riser Loose Tube Stub

2x16 standard

Loose Tube Pigtails

Dual 1x4 standard

Ribbon Pigtails

Distribution Stub Length

Distribution Cable Type

6/09

Outside Plant Fiber and Copper Solutions

Cabinet Size

See ADC literature #104470AE


www.adc.com

+1-952-938-8080

1-800-366-3891

436

OmniReach FTTP Solutions


ADCs new OmniReach Fiber Splitter Box
(FSB) enables customers to accelerate their
FTTX deployments more effectively and is an
ideal solution when deploying FTTX networks
in non-residential Multiple Tenant Unit (MTU)
and residential Multiple Dwelling Unit (MDU)
applications.

Outside Plant Fiber and Copper Solutions

These wall boxes provide a small footprint


for splitting, splicing and terminating and are
environmentally rated for indoor or outdoor use.
Available in three sizes, each box is equipped with
a 12-fiber splice tray allowing for an input splicing
option. FSBs accept standard Plug-and-Play (PNP)
splitters (same as in the Fiber Distribution Hub
3000 or FDH 3000) and splitters can be easily
added after the wall box has been installed. FSBs
accommodate 1x4, 1x8, 1x16 and 1x32 splitters;
up to 72 fibers.
FSBs offer increased efficiency within distinct
FTTX network applications. Featuring a compact
solution for wall mounting, these boxes provide
a significant space savings while maintaining
hand access to connectors. The unique swing
frame design also allows for easy access to the
back section of the wall box. For use in MTUs, as
well as garden style, mid-rise and high-rise MDU
buildings, FSBs allow for a de-centralized MDUONT (Optical Network Termination) architecture
and offer an economical solution for MTU/MDU
applications where a larger sized FDH is not
economical, i.e. strip malls and rural areas.

6/09

106612AE

Next Gen Network Solutions

Fiber Splitter Box (FSB)

See ADC literature #105947AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

437

OmniReach FTTP Solutions


Fiber Splitter Box (FSB)

FSB-16 - Indoor/Outdoor Enclosure


Features and Benefits

Traditional swing frame design allows for


access to the back section of the wall box
Splitter can be easily installed after wall
box install
Standard 12-fiber splice tray allows for input
splicing option
Output pigtails can either be stored internally
or routed externally for MDU-ONT connection
Accepts standard PNP splitter
(same as FDH 3000)

106612AE

Next Gen Network Solutions

Rated for indoor or outdoor use

6/09

Outside Plant Fiber and Copper Solutions

Accommodates up to 16 ports

See ADC literature #105947AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

438

OmniReach FTTP Solutions


Fiber Splitter Box (FSB)

FSB-32 Indoor Enclosure

6/09

106612AE

Dual hinge design creates separation between


rear splitter section and front customer side
access
Splitters can be easily installed after wall box
install allowing for separate purchase
Standard 12-fiber splice tray allows for input
splicing option

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Features and Benefits

Accommodates up to 32 splitter ports for one


splitter module
Dual hinge provides small footprint on the
wall while maintaining excellent hand access
to connectors
Accepts standard PNP splitter
(same as FDH 3000)

FSB-72 Outdoor Enclosure


Features and Benefits
Traditional swing frame design allows for
access to the back section of the wall box
Splitter can be easily installed after wall
box install
Standard 12-fiber splice tray allows for input
splicing option
Accommodates up to 3 PNP splitter modules
72 port capacity with built-in 32-port parking
Easily wall mounts to buildings
Accepts standard PNP splitter
(same as FDH 3000)

See ADC literature #105947AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

439

OmniReach FTTP Solutions


Fiber Splitter Box (FSB)

Catalog Number
FSB- __ __ __ __ __ __ __ __ __ __ __
1

2 Enclosure Type
Code

Description

Capacity

Size (HxWxD)

Indoor FSB-32

32-Fiber

8"x13"x5"

Outdoor FSB-72

72-Fiber

13"x19"x8"

Indr/Outdr FSB-16 16-Fiber

9"x9"x3.5"

SC/APC

4 Splice Tray (Feeder Side)


2

Heat Shrink Fusion

Mechanical/Ribbon

No Splice Tray

12 12 Fibers
16 16 Fibers
32

32 Fibers

48

48 Fibers

72 72 Fibers

None Installed

1x32 Standard

1x16 Standard

2x32 Standard Power

1x8 Standard

Dual 1x8 Standard

Dual 1x16 Standard

1x4 Standard

2x16 Standard

Dual 1x4 Standard

One (1) Installed

Two (2) Installed

Three (3) Installed

Front Lock 1, Rear Lock 2

Front Lock 1, No Rear Lock

Rear Lock 2, No Front Lock

No Stub

2 Fibers

4 Fibers

6 Fibers

8 Fibers

000

0 Feet

025

25 Feet

100

100 Feet

200

200 Feet

300

300 Feet

500

500 Feet

8 Cable Type (Feeder Cable)


0

Adapters Only
(No Pigtail for Feeder)

Pigtails
A

Splice Ribbon Pigtail Assy

Splice Pigtails (900 Micron)

Stubs

None

Front Lock 1, Rear Lock 1

Adapters

7 Splitter Qty Installed


0

None (Pad Lock Ready)

9 Feeder Cable Length

6 Splitter Type Installed

5 Fiber Count (Distribution)

0
A

10 Feeder Fiber Count

3 Connector Type

106612AE

Next Gen Network Solutions

Standard

6/09

Outside Plant Fiber and Copper Solutions

9 10 11

11 Key Locks

1 Configuration
S

Ribbon OSP Cable

Ribbon IFC Cable

Loose Tube OSP Cable

Loose Tube IFC Cable

900um IFNR Cable

See ADC literature #105947AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

440

OmniReach FTTP Solutions

Outside Plant Fiber and Copper Solutions

The Outdoor Fiber Distribution Terminal 24


(oFDT-24) is designed to terminate, splice and
interconnect fiber optic cables in an outdoor
environment. This terminal may be adapted to
Fiber-to-The-Premise (FTTP) Multiple Dwelling
Unit (MDU) applications and is particularly suited
for garden style MDU buildings. The enclosure is
mounted to the exterior surface of a dwelling and
connects the distribution cable and drops routed to
individual living units. The cables meet at a central
connector field that includes termination for the
distribution cable and parking for the drop cables.
The cabinet may be configured with splice trays for
splicing the cable to connector pigtails. The oFDT24 may be pre-terminated on the distribution side
with outside plant cable stubs so that the unit is
quickly connected to the plant. The oFDT-24 may
also be pre-wired with pigtails on the drop side so
that individual drops routed into the unit can be
spliced to the connectorized pigtails.
The oFDT-24 features a unique swing frame
type design that separates the splicing in the rear
from the patch access in the front of the swing
frame. It allows for easy connector access to the
rear connectors for maintenance and cleaning.
This approach allows for a single door sealing
method, ensuring reliability to withstand longterm outdoor conditions.
The unit accommodates a variety of OSP cable
types via sealed grommet entry. Cables are secured
with standard grip clamps to provide required pull
out strength. The enclosure provides grounding for
metallic members and for the cabinet.
The oFDT-24 product accommodates 6, 12,
or 24 living units. Distribution cable fibers are
terminated on standard SC/APC adapters that
are easily accessible for service connection and
maintenance. Drop pigtails are initially terminated
on parking adapters adjacent to the distribution
termination adapters and staged at the parking
positions until the living units request service.
Moving the drop pigtails from the parking
position to the assigned distribution fiber allows
for easy service connections.

6/09

106612AE

Next Gen Network Solutions

Outdoor Fiber Distribution Terminal 24 (oFDT-24)

See ADC literature #103335AE


www.adc.com

+1-952-938-8080

1-800-366-3891

441

OmniReach FTTP Solutions

Outdoor Fiber Distribution Terminal 24 (oFDT-24)

Next Gen Network Solutions

The new oFDT-24 design allows for micro-ducts


to enter into the back of the oFDT box. The 8" x
3" oval cut-out on the right side of the back wall
allows the installer to locate the oFDT right over
the micro-ducts exiting the building. This feature
eliminates the need for the transitional NEMA
box used to transition from the micro-duct exit
location into the oFDT. This new feature offers
cost, labor, and aesthetic benefits to the MDU
building owners over the current installation
method. When not used, the oval cut-out can be
covered with the provided gasketed plate. There
is also a knock-out hole in the bottom of the
cabinet to accommodate every type of installation
application.

Features and Benefits


Accommodates smaller fiber counts; 6-, 12and 24-fiber
Eliminates need for transitional NEMA box
that provides for mini-ducts

New
Outdoor FDT Installation Method

NEMA 3R
Enclosure
Liquid
Tight
Fitting
1.25 Liquid
Tight Conduit
Liquid Tight
Fitting
Current
Outdoor FDT Installation Method

Liquid tight fittings offer cost savings


Aesthetic benefits to MDU building owners
Supplied with parking, pigtails and splice
tray
Wall-mount; efficient use of wall space
Cable termination and splicing

106612AE

Complete connector access

6/09

Outside Plant Fiber and Copper Solutions

Advantages and Cost Benefits of


New oFDT-24

Lockable 216 tool/padlock offers flexible


security options
Environmental enclosure provides heavy-duty
protection from wind, dust, rain, and other
contaminants
Aluminum welded construction provides
strength and resists corrosion
Lightweight structure provides for easy
installation
Cable entrance ports seal cable at entry
Cable management and routing limits radius
and adds strain relief
Standard stub lengths of 100, 300, 500, and
1000 feet

See ADC literature #103335AE


www.adc.com

+1-952-938-8080

1-800-366-3891

442

OmniReach FTTP Solutions

Outdoor Fiber Distribution Terminal 24 (oFDT-24)


Catalog Number
FDT- __ __ __ __ __ __ __ __ __ __ __

oFDT-24

000

Connector Type
J

SC/APC

Splice Tray

0 Feet

025

25 Feet

100

100 Feet

200

200 Feet

300

300 Feet

500

500 Feet

Cable Type

No Tray

Pigtails

Heat Shrink Fusion

Mechanical/Ribbon

Bare Ribbon Pigtail


Assembly

Pigtails (Colored)

Fiber Count
06

Stubs

6 Fiber

12 12 Fibers
24

24 Fibers

Parking
P

Parking

No Parking

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Pigtails
P

Pigtails (2mm)

No Pigtails

6/09

See ADC literature #103335AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

443

Outside Plant Fiber and Copper Solutions

Stub Length

106612AE

Next Gen Network Solutions

Enclosure

OmniReach FTTP Solutions

The unit accommodates a variety of OSP cable


types via sealed grommet entry. Cables are
secured with standard grip clamps to provide
required pull out strength. The enclosure provides
grounding for metallic members and for the
cabinet.

106612AE

Next Gen Network Solutions

The ADC Outdoor Fiber Distribution Terminal 48F


(oFDT-48) is designed to terminate, splice
and interconnect fiber optic cables in an outdoor
environment. This terminal may be adapted to
Fiber-to-The-Premise (FTTP) Multiple Dwelling Unit
(MDU) applications by mounting the enclosure to
the exterior surface of a dwelling and connecting
between the distribution cable and drops
routed to individual living units. The oFDT-48 is
typically divided into two side-by-side sections
with distribution cable routed into one side and
drop cable routed into the other side. The cables
meet at a central connector field that includes
termination for the distribution cable and parking
for the drop cables. Each side of the cabinet may
be configured with splice trays for splicing
the cable to connector pigtails. The oFDT-48 may
be pre-terminated on the distribution side
with outside plant cable stubs so that the unit is
quickly connected to the plant. The oFDT-48 may
be pre-wired with pigtails on the drop side so
that individual drops routed into the unit can be
spliced to the connectorized pigtails.

6/09

Outside Plant Fiber and Copper Solutions

Outdoor Fiber Distribution Terminal 48 (oFDT-48)

See ADC literature #103333AE


www.adc.com

+1-952-938-8080

1-800-366-3891

444

OmniReach FTTP Solutions

Outdoor Fiber Distribution Terminal 48 (oFDT-48)

6/09

106612AE

The oFDT-48 product accommodates up to


48 living units. Distribution cable fibers are
terminated on standard SC/APC adapters that
are easily accessible for service connection and
maintenance. Drop pigtails are initially terminated
on parking adapters adjacent to the distribution
termination adapters and staged at the parking
positions until the living units request service.
Moving the drop pigtails from the parking
position to the assigned distribution fiber easily
makes service connections.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Sizes

Mounting Applications
All units are configurable for a variety of
mounting arrangements including wall, pole
and pedestal mounting. Each unit is provided
nominally with a wall mount bracket. Optional
pole-mount brackets and pedestals may be
ordered separately.

Special Features
These heavy gauge aluminum enclosures provide
the necessary protection against rain, wind, dust,
rodents and other environmental contaminants
while remaining lightweight for easy installation.
The aluminum construction with heavy powder
coat finish also provides for corrosion resistance.

Features and Benefits


Environmental enclosure provides heavyduty protection from wind, rain, and other
contaminants
Aluminum welded construction provides
strength and resists corrosion
Flexible design accommodates 24 and 48
fibers including termination and parking
Lightweight structure provides for easy
installation
Lockable tool or padlock offers flexible
security options
Cable entrance ports seal cable at entry
Cable management and routing limits radius
and adds strain relief

See ADC literature #103333AE


www.adc.com

+1-952-938-8080

1-800-366-3891

445

OmniReach FTTP Solutions

Outdoor Fiber Distribution Terminal 48 (oFDT-48)


Catalog Number
FDT- __ __ __ __ __ __ __ __ __ __ __

oFDT-48

Pigtails (2mm)
No Pigtails

Cable Type

Connector Type
J

P
X

Pigtails

SC/APC

Bare Ribbon Pigtail Assembly

Pigtails (Colored)

Stubs

Splice Tray
0

No Tray

Heat Shrink Fusion

Mechanical/Ribbon

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Fiber Count
24 24 Fibers
48

Stub Length

48 Fibers

Parking

000

0 Feet

025

25 Feet

100

100 Feet

Parking

200

200 Feet

No Parking

300

300 Feet

500

500 Feet

106612AE

Next Gen Network Solutions

Enclosure

6/09

Outside Plant Fiber and Copper Solutions

Pigtails

See ADC literature #103333AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

446

OmniReach FTTP Solutions


The Indoor Fiber Distribution Terminal (iFDT)
provides Multiple Dwelling Unit (MDU)
applications with a compact and secure family of
enclosures for connecting fiber cables at MDUs.
The iFDT products utilize a rugged double-hinged
design that effectively isolates the splicing and
cable termination in the rear compartment
from the jumper interconnection in the front
compartment. Separating the cable splicing and
termination into a layered configuration provides
a space efficient and craft friendly interface
unit. The layered iFDT staggered interconnection
field provides ease of access to all connections.
The iFDT enclosure provides standard SC/APC
connections and parking adapters for locating the
connectorized pigtails prior to deployment.

Outside Plant Fiber and Copper Solutions

6-Port

Features
Designed to splice and terminate 6-, 12-, 24and 48-fibers
Integrated splice tray offers flexible splice
management for individual or mass splicing

24-Port

Sealed enclosure protects fibers from dust,


water spray, insects and other contaminants
Dual-hinged design ensures separation of
owner/client network segments
NEMA-12 Rated
Tested to GR-2898-CORE
Front and rear layer maximizes wall space
utilization for both splicing and interconnect
Robust steel construction protects fibers
against damage and ensures network
reliability
Slotted cable entrance ports allow for rapid
cable installation and pass-through capability

12-Port

Cable management and routing limits bend


radius and adds strain relief
216-Tool (can wrench), key lock or padlock
offers flexible security options

6/09

106612AE

Next Gen Network Solutions

MDU iFDT

48-Port

See ADC literature #103266AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

447

OmniReach FTTP Solutions


MDU iFDT

Catalog Number
FDT- __ __ __ __ __ __ __ __

Max Capacity

000

0 Feet

Desc.

w/Prkg

w/o Prkg

025

25 Feet

iFDT-6/12

6-Fiber

12-Fiber

100

100 Feet

A
B

iFDT-12/24

12-Fiber

24-Fiber

200

200 Feet

iFDT-24/48

24-Fiber

48-Fiber

300

300 Feet

iFDT-48/96

48-Fiber

96-Fiber

500

500 Feet

Connector Type
J

Cable Type

SC/APC

Pigtails

Splice Tray

Bare Rbn Pgtl Assy

Pigtails (Colored)

No Tray

Heat Shrink Fusion

Ribbon OSP w/Conn

Mechanical/Ribbon

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Stubs

Fiber Count
06

6 Fiber

12 12 Fibers
24

24 Fibers

48

48 Fibers

Pigtails
P

Pigtails (2mm)

No Pigtails

72 72 Fibers
96

Parking

96 Fibers

Parking

No Parking

106612AE

Next Gen Network Solutions

Enclosure Type
Code

6/09

Outside Plant Fiber and Copper Solutions

Stub Length

See ADC literature #103266AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

448

OmniReach FTTP Solutions


Indoor Fiber Distribution Terminals - CPE

Outside Plant Fiber and Copper Solutions

The ADC Indoor Fiber Distribution Terminal (iFDT)


series provides Customer Premises Equipment
applications with a compact and secure family
of enclosures for connecting fiber cables within
building entrance locations, communication
closets, computer rooms and other indoor
environments. The iFDT products utilize a rugged
double-hinged design that effectively isolates
the splicing and cable termination in the rear
compartment from the jumper interconnection
in the front compartment. Separating the
cable splicing and termination function from
the interconnection function allows the unit to
be used as a dual-access product with secure
lockable access provided for each compartment.
The layered iFDT and staggered interconnection
field provides ease of access to all connections.
The iFDT enclosure provides mounting positions
for standard APLH modular adapter panels(12packs, 8-packs, 6-packs, etc.) accommodating
any industry standard adapters.

Sizes
The iFDT products are designed to splice and
terminate fibers in a range of sizes including 6,
12, 24, 48, 72, and 96 fibers.

Mounting Applications
The ADC iFDT Series cabinets are for indoor
wall mount applications and are designed to
NEMA-12 rating. The dual hinged design allows
complete front and rear access. The two secure
doors are locked with a standard can wrench tool
and may optionally be secured with a standard
pad-lock. The unit may also be configured for
single lock entry thus allowing the products to be
used for single access applications.

6/09

106612AE

Next Gen Network Solutions

Product Description

See ADC literature #103562AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

449

OmniReach FTTP Solutions


Indoor Fiber Distribution Terminals - CPE

Next Gen Network Solutions


106612AE

The enclosures accommodate optical component


modules allowing the unit to house splitters,
WDMs, filters and other optical components.
For splicing applications, ADCs splice trays can
be installed to support either individual fusion
splicing or mass fusion splicing. The units provide
sealed cable ports for cables and interconnection
cables and gaskets to protect against dust and
water spray. The units can also be configured
with a standard cable grip kit to provide strain
relief for incoming fiber cables. The splice
compartment provides ample space for storing
loose-tube, ribbon or individual fiber slack.

Features
12-Packs provide for high-density
terminations and conserve wall space.
Integrated splice tray offers flexible splice
management for individual or
mass splicing.
Sealed enclosure protect fibers from dust,
water spray, insects and
other contaminants.
Dual-hinged design ensures separation
of owner/client network segments.
Designed to NEMA-12
Designed to GR-2898-CORE
Front and rear layer maximizes wall space
utilization for both splicing
and interconnect.
Robust steel construction protects fibers
against damage and ensures network
reliability.
Slotted cable entrance ports allow for rapid
cable installation and pass-through capability.
Cable management and routing limits bend
radius and adds strain relief.
216-Tool (can wrench), key lock or padlock
offers flexible security options.

6/09

Outside Plant Fiber and Copper Solutions

Fiber Management

See ADC literature #103562AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

450

OmniReach FTTP Solutions


Indoor Fiber Distribution Terminals - CPE
Catalog Number

Stub Length
000

0 Feet

iFDT-12

12 Fiber

iFDT-24

24 Fiber

025

25 Feet
100 Feet

iFDT-48

48 Fiber

100

iFDT-72

72 Fiber

200

200 Feet

iFDT-96

96 Fiber

300

300 Feet

500

500 Feet

Connector Type
N

SC/UPC

SC/APC

Cable Type
Pigtails

Splice Tray
0

No Tray

Heat Shrink Fusion

Mechanical/Ribbon

6 Fiber

12

12 Fiber

24

24 Fiber

48

48 Fiber

72

72 Fiber

96

96 Fiber

Bare ribbon pigtail assy

Pigtails (Colored)

Stubs

Fiber Count
06

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

6/09

See ADC literature #103562AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

451

Outside Plant Fiber and Copper Solutions

Enclosure Type/Capacity

106612AE

Next Gen Network Solutions

FDT- __ __ __ __ N X __ __

OmniReach FTTP Solutions

Next Gen Network Solutions

ADCs new OmniReach Wall Splice Cabinets


(WSC) provide a versatile splicing solution when
deploying FTTX networks in todays Multiple
Dwelling Unit (MDU) buildings. The cabinets
are available in indoor and indoor/outdoor
configurations making them suitable for splicing
requirements anywhere in an MDU architecture.
The WSC also offers slack storage and is easily
accessible with its wall-mount design.

WSC-24 Features
Rated for indoor use
Accommodates up to (2) 12-fiber splice trays
Built-in slack storage around splice trays
Flexible cable entry location with its 4 cable
entry port design
Top and bottom cable entry ports allow for
pass through splicing capability
Standard 216 tool access
Padlock and/or key lock security option

WSC-48 Features
Rated for indoor and outdoor use
Accommodates up to (4) 12-fiber splice trays
Built-in slack storage around splice trays
Standard 216 tool access
One part number can accommodate indoor or
outdoor demand

106612AE

Padlock security

6/09

Outside Plant Fiber and Copper Solutions

Wall Splice Cabinet

See ADC literature #106425AE


www.adc.com

+1-952-938-8080

1-800-366-3891

452

OmniReach FTTP Solutions


Wall Splice Cabinet

Catalog Number
WSC-S __ 0 __ __ 1 __
Key Locks

Indoor WSC-24 (24-fiber)

None (Padlock Ready)

Indoor/Outdoor WSC-48 (48-fiber)

Front Lock 1

Splice Tray (provider side)


2

Heat Shrink Fusion

12

12 Fibers

Mechanical/Ribbon

24

24 Fibers

No Splice Tray

36

36 Fibers

48

48 Fibers

Outside Plant Fiber and Copper Solutions

Fiber Count

6/09

106612AE

Next Gen Network Solutions

Enclosure Type

See ADC literature #106425AE


www.adc.com

+1-952-938-8080

1-800-366-3891

453

OmniReach FTTP Solutions

Next Gen Network Solutions


106612AE

6/09

Outside Plant Fiber and Copper Solutions

RealFlex MDU Drop Cables

ADCs new RealFlex MDU Drop Cables are


an ideal solution for the unique challenges
encountered when deploying FTTX networks in
todays Multiple Dwelling Unit or MDU buildings.
RealFlex MDU Drop Cables are offered in Indoor/
Outdoor, Riser and Plenum cable types making
them suitable for all types of MDU structures.
RealFlex MDU Drop Cables allow for a bend
radius as small as 7.5 mm without changing
attenuation characteristics of the cable and
improve insertion loss (IL) performance for 90
degree bend locations. With the average MDU
installation including as many as seven 90 degree
turns, this new fiber greatly reduces the risk to
bend induced IL during installation. In addition
to the improved bend radius performance, the
rugged 3mm cable construction provides the
flexibility and durability to withstand the most
demanding applications.
The rugged 3 mm indoor/outdoor cable can be
stapled*, allowing for fast and easy securing of
cables to most surfaces. The reduced bend radius
glass allows the technician to staple around
tight corners without compromising insertion loss
performance.
ADCs RealFlex MDU Drop Cables provide for
quick and easy deployments with increased
reliability which allow for fast service turn-up,
improved network reach and lower overall
network operating and maintenance costs.
*ADC approved staplers and staples.

Typical Applications:
Garden or horizontal; indoor/outdoor cable
used to transition from an outdoor fiber
distribution terminal to each indoor living unit
Mid or high-rise; all three cable types can
be used to transfer from an indoor fiber
distribution terminal to each individual living
unit within a building
Indoor/outdoor and riser cables are suitable
for all OFNR applications; OFNP applications
will require plenum cable

See ADC literature #105715AE


www.adc.com

+1-952-938-8080

1-800-366-3891

454

OmniReach FTTP Solutions


RealFlex MDU Drop Cables
Features and Benefits

Greatly reduces risk to bend induced insertion


loss created during installation
Indoor/Outdoor, Plenum and Riser cable
options available

G.657 Table A and B compliant


Two cable configurations available: connectors
on both ends or connector on one end
Spooling options: end with connector pulled first
or end without connector pulled first

1550 nm

dBr

Reference

Standard Fiber

Reduced Bend Radius Fiber

Stapled 3mm RealFlex MDU Drop Cables

6/09

See ADC literature #105715AE


www.adc.com

+1-952-938-8080

1-800-366-3891

455

Outside Plant Fiber and Copper Solutions

Ivory cable color helps distinguish cable


in the field

Rugged 3 mm cable jacket construction

106612AE

Next Gen Network Solutions

Bend radius as small as 7.5 mm without changing


cable characteristics

OmniReach FTTP Solutions


RealFlex MDU Drop Cables

Catalog Number
MDC- __ __ __ __ - __ __ __ __ __ __

APC SC

UPC SC

Spool Option

Connector 2 Type
J

APC SC

UPC SC

Stub

No Spool

Standard Spool

Spooled Connector First

Spooled Connector Last

Standard Cable Measurement

Number of Fibers
1

Feet

Meters

One
Standard Cable Lengths

Cable Type
(RBR) Reduced Bend Radius
F

RBR Indoor/Outdoor Ivory

RBR Plenum Ivory

RBR Riser Ivory

0010

10

0050

50

0100

100

0150

150

0200

200

0250

250

0500

500

106612AE

Next Gen Network Solutions

6/09

Outside Plant Fiber and Copper Solutions

Connector 1 Type

See ADC literature #105715AE


www.adc.com

+1-952-938-8080

1-800-366-3891

456

OmniReach FTTP Solutions

6/09

106612AE

ADCs new RealFlex Drop Cables are an ideal


solution for the unique challenges encountered
in the diversity of multi-tenant unit (MTU) and
multi-dwelling unit (MDU) FTTX deployments.
RealFlex Drop Cables allow for a bend radius as
small as 7.5 mm without changing attenuation
characteristics of the cable and improve
insertion loss (IL) performance for 90 degree
bend locations. With the average MTU or MDU
installation including as many as seven 90 degree
turns, this new cable greatly reduces the risk to
bend induced IL during installation. In addition
to the improved bend radius performance, the
rugged cable construction provides the flexibility
and durability to withstand the most demanding
applications. The rugged indoor/outdoor cables
can also be stapled*, allowing for fast and easy
securing of cables to most surfaces. The reduced
bend radius glass allows the technician to staple
around tight corners without compromising
insertion loss performance. *ADC approved
staplers and staples.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

RealFlex 5 Drop Cables

ADCs RealFlex 5 Drop Cables use 5.0 mm cable


with Reduced Bend Radius fiber for optimal
performance in the most constraining installation
environments and hardened connectors for
fast service turn-up. The hardened connectors
are environmentally sealed and terminated in
the factory to produce the highest reliability
standards. Multiple dwelling units and commercial
business applications are ideal environments
for this indoor/outdoor reduced bend radius
hardened drop cable.

Features and Benefits


Bend radius as small as 7.5 mm without
changing cable characteristics
Greatly reduces risk to bend induced insertion
loss created during installation
Rugged 5.0mm indoor/outdoor cable jacket is
composed of Low-Smoke Zero-Halogen
rated materials and incorporates water
swellable yarns
Hardened connector option fully compatible
with OptiTap connector system

OptiTap is a registered trademark of Corning Cable Systems Brands, Inc.

See ADC literature #106501AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

457

OmniReach FTTP Solutions

RealFlex HD 90 degree bend

Ordering Information
Catalog Number
FHD- __ __ 1K-0 __ M
Connector Type
H

Length

Hardened Connector

Connector Type
0

None - Stub End

Hardened Connector

030

30 Meters

050

50 Meters

080

80 Meters

150

150 Meters

220

220 Meters

106612AE

Next Gen Network Solutions

RealFlex HD knot

6/09

Outside Plant Fiber and Copper Solutions

RealFlex 5

See ADC literature #106501AE


www.adc.com

+1-952-938-8080

1-800-366-3891

458

OmniReach FTTN Solutions

106612AE

The NCX-1000 is a passive fiber-to-the node


(FTTN) service delivery cabinet that is easily
placed in the feeder or distribution plant to
support any re-sectionalizing or broadband
overbuild application. It is typically installed with
an adjunct DSLAM cabinet or remote terminal
that houses a broadband DSLAM. The compact
cabinet is designed for FTTN applications where
re-sectionalizing the network requires either a
new cross-connect interface with a 1:2 ratio of
feeder to distribution pairs or for 1:1 ratios where
ADCs patented Distribution Intercept (DI) service
delivery solution is used. The NCX-1000 family
of cabinets supports up to 900 feeder circuits
and 1800 distribution circuits with 432 DSLAM
input and output ports in a non-protected FDI
configuration. Options for non-protected and
protected DSLAM circuits utilizing ComProtect
high performance protection are available.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

NCX-1000: Large Cabinet for FTTN Broadband Service Delivery

ADCs OmniReach FTTX Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.

Features
Drop down panels offer easy access to OSP
cable stubs for splicing into DSLAMs and
network
FDI (1:2) and patented Distribution Intercept
(DI) (1:1) configurations available
Works with existing F1/F2 cross box or can
replace it
Able to groom all existing xDSL shelves into
a single format and provide cross-connect
capability in addition to pair-bonding
Supports in-cabinet circuit protection

6/09

Meets GR-487 requirements

See ADC literature #105052AE


www.adc.com

+1-952-938-8080

1-800-366-3891

459

OmniReach FTTN Solutions

NCX-1000: Large Cabinet for FTTN Broadband Service Delivery


Ordering Information
NCX-1000 Cabinet FDI (1:2) Protected Configuration
Equipped with 600 feeder pairs and 1200 distribution pairs with 864 DSLAM
ports in/out protected. Includes Insertion Tool and LSA-PLUS Series 2 test cord.
Order ComProtect protection modules separately.

KCE-FJA600X1200-2

NCX-1000 Cabinet FDI (1:2) Non-Protected Configuration


Equipped with 900 feeder pairs and 1800 distribution pairs with 432 DSLAM
ports in/out non-protected. Used for applications where adjunct DSLAM cabinet is
equipped with protection for DSLAM input and output circuits. Includes Insertion
Tool and LSA-PLUS Series 2 test cord.

KCE-FJA900X1800-2N

NCX-1000 Cabinet FDI (1:2) Non-Protected Configuration


Equipped with 900 feeder pairs and 1350 distribution pairs with 648 DSLAM
ports in/out non-protected. Used for applications where adjunct DSLAM cabinet is
equipped with protection for DSLAM input and output circuits. Includes Insertion
Tool and LSA-PLUS Series 2 test cord.

KCE-FJA900X1350-3N

NCX-1000 Cabinet DI (1:1) Non-Protected Configuration


Equipped with 1600 OSP Intercept pairs in/out and 216 DSLAM ports in/out.
Can accommodate up to 864 DSLAM ports. Additional block assemblies ordered
separately. Used for applications where adjunct DSLAM cabinet is equipped with
protection for DSLAM input and output circuits. Includes Insertion Tool and LSAPLUS Series 2 test cord and green activation plugs.

KCE-DJA1600-1N

Accessories
Insertion Tool

6417 2 055-01

Look-both-ways test cord for Series 2

6647 2 900-01

LSA-PLUS Series 2 green activation plugs for xDSL activation


(for KCE-DJA1600-1N) Quantity: 1 (order in multiples of 100)

6089 3 055-02

Pad Mount Frame for NCX-1000 Large Cabinet

ACE-304PMF

ComProtect solid state overvoltage protection module for applications up to


ADSL2+. Two protectors required per circuit. Black housing.

6659 1 010-30

ComProtect gas discharge tube overvoltage protection module


for applications up to VDSL2. Two protectors required per circuit.

PRO-6659 1 509-30B

106612AE

Next Gen Network Solutions

Catalog Number

6/09

Outside Plant Fiber and Copper Solutions

Description

See ADC literature #105052AE


www.adc.com

+1-952-938-8080

1-800-366-3891

460

OmniReach FTTN Solutions


The NCX-1000 service delivery cabinet integrates
ADCs patented Distribution Intercept (DI)
broadband service delivery cross-connect inside a
compact pad or pole mounted cabinet specifically
designed for todays new breed of hardened
(brick) DSLAMs. The NCX-1000 family of cabinets
supports from 48 to 144 DSLAM ports and up to
600 OSP Intercept pairs in/out. It allows strategic
placement deep in the network to achieve
required loop lengths for optimum bandwidth
on xDSL services. Simple, straight splicing to the
outside plant cable is all that is needed to begin
turning up customers from a central location.

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

NCX-1000: Small and Medium Cabinets for FTTN Broadband Service Delivery

ADCs OmniReach FTTX Solutions are the


industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.

Features and Benefits


Single cabinet solution houses DSLAMs and DI
service delivery crossconnect
Works with existing crossbox or can replace it
Easily splices into the feeder or distribution
plant
Able to groom all existing xDSL shelves into
a single format and provide cross-connect
capability in addition to pair-bonding

6/09

106612AE

Provides a consistent interface for technicians


Can be deployed in feeder or distribution
outside plant cable, the most flexible solution
available
Fastest to deploy, only straight splicing
activities to OSP required
Unique look-both-ways test capability without
lifting wires reduces time for technicians to
isolate network problems
Distribution Intercept (DI) offers the most
streamlined approach to xDSL delivery, green
activation plugs offer visual indication of
working broadband customers
Preserves investment in existing copper plant

See ADC literature #104975AE


www.adc.com

+1-952-938-8080

1-800-366-3891

461

OmniReach FTTN Solutions

NCX-1000: Small and Medium Cabinets for FTTN Broadband Service Delivery
Ordering Information
Description

Catalog Number

Small Pole-or Pad-Mount Cabinet NCX-10487P00


Distribution intercept service delivery cabinet with 200 pair OSP with MS2
connectors and 96 DSLAM ports in/out with 710 connectors. Includes Insertion Tool
and LSA-PLUS Series 2 green activation plugs.

NCX-10487P00

Bracket supports first Adtran Total Access-1148 DSLAM and


first 1100F aggregation unit

6652 2 175-00

Bracket for second Adtran Total Access-1148 only

6652 2 175-01

Pole mount kit for NCX-10487P00

OSP-PMK-100

Pad mount frame for NCX-10487P00

ACE-102PMF

NCX-10487P00 split skirt riser 6" for pad mount frame

ACE-ACCSPCR06S-102

Distribution intercept service delivery cabinet, 1-3 hardened DSLAMs, 144 ports
in/out with 710 connectors and 600 OSP intercept in/out pairs with MS2
connectors. Includes Insertion Tool and LSA-PLUS Series 2 green activation plugs.

NCX-144600

Bracket supports first Adtran Total Access-1148 DSLAM and first 1100F
aggregation unit

6652 2 175-00

Bracket for second Adtran Total Access-1148 only

6652 2 175-01

Bracket for third Adtran Total Access-1148 and second 1100F aggregation

6652 2 175-03

Pole mount kit for NCX-144600

OSP-PMK-001

Pad mount frame for NCX-144600

ACE-152PMF

NCX-144600 split skirt riser 6" for pad mount frame

ACE-ACCSPCR06S-152

Accessories
Insertion Tool

6417 2 055-01

Look-both-ways test cord for LSA-PLUS Series 2 blocks

6647 2 900-01

LSA-PLUS Series 2 green activation plugs used for xDSL activation


Quantity: 1 (order in multiples of 100)

6089 3 055-02

106612AE

Next Gen Network Solutions

Medium Pole-or Pad-Mount Cabinet NCX-144600

6/09

Outside Plant Fiber and Copper Solutions

See ADC literature #104975AE


www.adc.com

+1-952-938-8080

1-800-366-3891

462

OmniReach FTTN Solutions

Outside Plant Fiber and Copper Solutions

The NCX-1000s service delivery cross connect


is designed for customers who use the
Emerson CoolPed cabinet for hardend DSLAM
applications. The NCX-1000s utilizes ADCs
patented Distribution Intercept (DI) broadband
service delivery cross-connect and mounts
inside the CoolPed cabinet offering the same
streamlined broadband service delivery as found
in ADC's family of NCX-1000 cabinets. The NCX1000s combined with the CoolPed allows you to
strategically place the cabinet anywhere in the
network to achieve the required loop lengths for
optimum bandwidth. Simple straight splicing to
the outside plant cable is all that is needed to
begin turning up customers.
ADCs OmniReach FTTX Solutions are the
industrys first infrastructure solutions designed
from the ground up to meet the unique
requirements of FTTX networks. Designed for
operational efficiency and scalability, OmniReach
solutions simplify FTTX network installation,
maintenance and management from the central
office/headend to the outside plant.
Features
NCX-1000s and mounting brackets for
CoolPed cabinet installation, OSP cable
stubs 12' for easy splicing into DSLAMs and
network
Works with existing feeder/distribution
cross box or can replace it
Sized from 48 DSLAM ports and 100 OSP
intercept pairs to 144 DSLAM ports and 600
OSP intercept pairs
A
ble to groom all existing xDSL shelves into
a single format and provide cross-connect
capability in addition to pair-bonding
Provides a consistent interface for technicians

CoolPed is a trademark of Emerson Network Power.

6/09

106612AE

Next Gen Network Solutions

NCX-1000s Distribution Intercept Cross-Connect for CoolPed Cabinets

See ADC literature #104982AE


www.adc.com

+1-952-938-8080

1-800-366-3891

463

OmniReach FTTN Solutions

NCX-1000s Distribution Intercept Cross-Connect for CoolPed Cabinets


Ordering Information
Description

Catalog Number

NIB-096200N12S

144 DSLAM ports in/out, 600 OSP intercept pairs

NIB-144600N12S

Accessories
Insertion Tool

6417 2 055-01

Look-both-ways test cord for LSA-PLUS Series 2

6647 2 900-01

LSA-PLUS Series 2 green plugs for xDSL activation


Quantity: 1 (order in multiples of 100)

6089 3 055-02

106612AE

Next Gen Network Solutions

96 DSLAM ports in/out, 200 OSP intercept pairs

6/09

Outside Plant Fiber and Copper Solutions

Distribution Intercept Cross Connect for Mounting in CoolPed Cabinet.


Includes mounting bracket, Insertion Tool and LSA-PLUS Series 2 green activation plugs.

See ADC literature #104982AE


www.adc.com

+1-952-938-8080

1-800-366-3891

464

OmniReach FTTN Solutions

Outside Plant Fiber and Copper Solutions

ADC's ComProtect 2/1 CP TP280A1 GDT


(Gas Discharge Tube) single-pair protection
module, when combined with ADC's LSA-PLUS
Series 2 connectivity, is a high-density system
that increases the pair capacity that can be
supported in OSP cabinets. The ComProtect GDT
system provides up to a 50% space savings over
traditional systems utilizing separate cross-connect
and protection fields. By reducing the number of
connection points, the ComProtect GDT system
improves technician productivity and reduces
failure rates. The ComProtect GDT module has
been designed for protecting high bandwidth
circuits, like VDSL2.

Features and Benefits


Meets applicable GR-1361-CORE, GR-63CORE, GR-78-CORE, GR-1252-CORE, and
SR-NWT-2759 Telcordia standards
Meets the "High-Speed Digital Networks
Operating up to 100 MHz" requirements of
Telcordia GR-974-CORE
Listed to UL 497
Meets NEBS Level 3 compliance
Supports VDSL2 transmission
Quick VDSL2 migration for upgrading from
xDSL2+ circuits by simply changing out solidstate ComProtect to ComProtect GDT
Cross-connection and protection in the same
footprint
Termination Block with integrated protection
Provides protection to your FTTN network
elements against overvoltage surges
ComProtect utilizes LSA-PLUS technology
therefore reducing network failure frequency
rates.
LSA-PLUS technology offers monitoring,
look-both-ways testing, without lifting crossconnect jumpers

6/09

106612AE

Next Gen Network Solutions

ComProtect Gas Discharge Tube: Single-Pair Protectors for Series 2 Switching Blocks

Ordering Information
Description

Catalog Number

ComProtect GDT 2/1 CP TP280A1


Quantity per Pack: 100

PRO-6659 1 509-30B

50-Pair Block
With 6' 25-Pair Cable Stubs and 710 Connectors

6659 1 005-10/06A

100-Pair Block
6' Stub and 710 Connectors
(4) 25-Pair 6 Cable Stubs and 710 Connectors

6659 1 105-00/06A
659 1 105-10/06A

See ADC literature #104560AE


www.adc.com

+1-952-938-8080

1-800-366-3891

465

OmniReach FTTN Solutions

ComProtect Gas Discharge Tube: Single-Pair Protectors for Series 2 Switching Blocks

Next Gen Network Solutions

Saves space combines protection and crossconnect fields into a single KRONE Series 2
block no additional interconnect terminal
blocks required
Up to 50% space savings over traditional
systems utilizing seperate cross-connect and
protection fields
E asy to use and maintain when inserted
into a Series 2 switching block, the field pair
can be isolated from the equipment side by
removing the protector and opening the circuit

Features and Applications


Meets applicable GR-974-CORE, GR-78-CORE
and GR-63-CORE standards
Meets UL 497 standard for paired conductor
communications circuit protection
Unique, high-density single-pair design allows pairs
to be isolated and easily replaced
Both 24- and 26-gauge wire can be used to create
a fuse link from the protection field to the OSP
network cable
Meets all standards for controlled environments
including temperature, humidity, office vibration
and airborne contaminants
Meets all standards for uncontrolled environments
including salt-fog, rain, fungus, airborne
contaminants and aging. Also meets standards for
environmental cycling for impulse and AC surges.
Meets GR-63 standards for transport and storage

NEBS Level 3 compliant


Insertion loss of less than 0.6 dB (up to 16 MHz)
The ComProtect module supports broadband
circuits, such as ADSL2+
Fiber to the Curb Applications
Provides a technician-friendly method of connecting
and protecting outgoing line powering pairs in ONU
(optical network unit) host cabinets.
DLC Remote Terminal OSP Pair Applications
Compact solution for all OSP pairs leaving DLC
cabinets. Saves space in the end chamber by
providing cross-connect and protection in one field
up to 100% space savings in certain applications.
Cabinet Overlay Applications
Compact 307 type replacement for protecting
inputs and outputs of DSLAM equipment.

106612AE

Designed for optimum performance


integrated, solid-state design enables quick,
reliable response

6/09

Outside Plant Fiber and Copper Solutions

ADC's ComProtect 2/1 CP ASU240A1 solid state


single-pair protection modules provide maximum
overvoltage protection in a minimum of space.
Plugging directly into ADC's LSA-PLUS Series 2
switching blocks, ComProtect products save space
and protect valuable, system-critical equipment.

See ADC literature #104560AE


www.adc.com

+1-952-938-8080

1-800-366-3891

466

OmniReach FTTN Solutions

ComProtect Gas Discharge Tube: Single-Pair Protectors for Series 2 Switching Blocks
Ordering Information
Description

Catalog Number

ComProtect Protectors with Ground Bars


Package of 10, black housing

5909 1 212-00

Package of 8, black housing

5909 1 211-00

ComProtect Protectors without Ground Bars


Package of 25
Black housing

6659 1 008-30

Yellow housing

6659 1 008-90

Red housing

6659 1 008-50

Package of 100
Black housing

6659 1 010-30

Yellow housing

6659 1 010-90

Red housing

6659 1 010-50

Ground Bars - Package of 10


10-pair used on 10-pair Series 2 blocks

6659 2 241-10

8-pair used on 8-pair Series 2 blocks

6659 2 242-10

6/09

See ADC literature #104560AE


www.adc.com

+1-952-938-8080

1-800-366-3891

467

Outside Plant Fiber and Copper Solutions

106612AE

Next Gen Network Solutions

OmniReach FTTN Solutions

KRONE Series 2 K110: 10-Pair Disconnect Block


Features
The original IDC termination block system

Next Gen Network Solutions

Series 2 10-pair disconnect block

U
 nique center port design allows for
patching or testing without removing
cross-connect wires or disrupting the circuit
Versatile mounting hardware allows
mounting on wall, in racks, etc.
Comprehensive labeling options

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

8-pair Series 2 block


Quantity: 1 (order in multiples of 10)
Snaps into Type 85 rod mount bracket or standard
Type 85 back mount frame

0.88" x 4.88" x 1.63"


(22.35mm x 123mm x 41.4mm)

6036 1 005-00

10-pair Series 2 K110 disconnect block


Quantity per Pack: 10
Snaps into universal mounting system, Type 105 rod
mount bracket or standard Type 105 back mount
frame. Wires can be terminated with either KRONE
insertion tool or industry-standard punchdown tool
equipped with 110-blade

0.88" x 4.88" x 1.63"


(22.35mm x 123mm x 41.4mm)

6468 5 102-00

10-pair Series 10 block


Quantity: 1 (order in multiples of 10)
Snaps into Type 85 rod mount bracket

0.88" x 4.06" x 1.63"


(22.35mm x 103.1mm x 41.4mm)

6730 1 001-00

10-pair Series 10 block


Quantity: 1 (order in multiples of 10)
Includes (20) 5mm spacers for even spacing on Type
85 rod mount bracket

0.88" x 4.06" x 1.63"


(22.35mm x 103.1mm x 41.4mm)

6730 1 001-01

106612AE

Available in 8- and 10-pair configurations

6/09

Outside Plant Fiber and Copper Solutions

Can be custom configured to meet specific


application requirements

See ADC literature #1303454


www.adc.com

+1-952-938-8080

1-800-366-3891

468

OmniReach FTTN Solutions

KRONE Series 2 K110: 25-/50-pair 89D-Style Blocks


Features

6/09

106612AE

Unique center port allows monitoring


and look-both-ways testing without
disturbing IDC
Double the density at the demarcation point
5-pair block

Available in traditional 25- and 50-pair


increments
Fits 89D-style mounting brackets
Preterminated blocks available with a range
of connector styles and positioning options
The K110 feature enables the termination of
wire with either the KRONE insertion tool or
any industry-standard punchdown tool with a
110 blade. Please note, the 5-pair disconnect
block is not K110 compatible.

25-pair block

50-pair block

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

25-pair disconnect block assembly


Quantity: 1
Field-terminated disconnect block; snaps into
89D bracket; includes label for empty half

10" x 3.38" x 1.38"


(254mm x 85.85mm x 35.05mm)

6639 1 003-01

50-pair disconnect block assembly


Quantity: 1
Field-terminated disconnect block; snaps into
89D bracket; includes label and label holder

10" x 3.38" x 1.38"


(254mm x 85.85mm x 35.05mm)

6652 1 880-10

5-pair disconnect block


Quantity:
Field-terminated disconnect block; mounts
directly to wall or in an enclosure
This block is not K110 compatible

2" x 2" x 1.25"


(50.8mm x 50.8mm x 31.8mm)

6585 2 002-00

See ADC literature #1303455.


www.adc.com

+1-952-938-8080

1-800-366-3891

469

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

Upgrade from 66-type technology

OmniReach FTTN Solutions

HighBand 10
Termination Block

HighBand 10 preterminated blocks are wired to industry standard 25-pair Telco connectors that
are mounted in the rear of the back mount frame, allowing for fast Broadband/DSL service
installations. The 25-pair connectors are oriented for top feed cable assemblies. These blocks are
available in 100-, 200- or 300-pair configurations.
HighBand 10 field-terminated kits are a flexible solution for custom applications where
preterminated blocks are not ideal.

Field-terminated Block Kits

Preterminated Block Assemblies

106612AE

Next Gen Network Solutions

HighBand 10 Category 5e termination blocks


utilize the silver plated, world renowned LSAPLUS contact principle. This technology has
become the industry standard in over 140
countries. The gas-tight contacts ensure a reliable
and long lasting connection. The frequent
rewiring that occurs in todays deployments can
quickly degrade the quality of wire terminations.
ADC products maintain superior connectivity
during hundreds of re-terminations and deliver
the best electrical performance in the industry.
The HighBand 10 block is available in both
preterminated units and field-terminated kits.

6/09

Outside Plant Fiber and Copper Solutions

HighBand 10: Termination Blocks

See ADC literature #103789AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

470

OmniReach FTTN Solutions


HighBand 10: Termination Blocks
Features & Benefits

6/09

106612AE

Preterminated blocks reduce installation time.


Labeling options allow for comprehensive
identification.

10-pair increment block is ideal for multi-pair


backbone cables.

The high-density IDC termination system allows


for more pair terminations in standard relay rack
applications.

HighBand 10 blocks are familiar to LSA-PLUS


Series 2 users and installers, eliminating the need
for additional training.

Field-terminated kits are a flexible solution for


custom applications.
Silver plated LSA-PLUS contacts provide corrosion
resistance.

Test port provides look-both-ways testing


capability without the removal of any wires; also
allows simple monitoring of a circuit using ADC
test cords.

Ordering Information
Dimensions
(H x W x D)

Description

Catalog Number

Preterminated Blocks
HighBand 10 100-pair block

245 mm x 124 mm x 94 mm
(9.66" x 4.88" x 3.69")

6637 1 150-60

HighBand 10 200-pair block

468 mm x 124 mm x 94 mm
(18.44" x 4.88" x 3.69")

6637 1 180-60

HighBand 10 300-pair preterminated block

689 mm x 124 mm x 94 mm
(27.12" x 4.88" x 3.69")

6637 1 210-60

HighBand 10 200-pair field-terminated back


mount frame kit

468 mm x 124 mm x 94 mm
(18.44" x 4.88" x 3.69")

6638 1 500-00

HighBand 10 300-pair field-terminated back


mount frame kit

689 mm x 124 mm x 94 mm
(27.12" x 4.88" x 3.69")

6638 1 300-50

HighBand 10 200-pair field-terminated rod


mount frame kit

473 mm x 124 mm x 94 mm
(18.63" x 4.88" x 3.69")

6638 1 180-50

Field-Terminated Kits

Accessories
HighBand 10 10-pair termination block

6468 2 061-00

HighBand to Series 2 one-pair adapter

6451 2 178-04

Red marking plugs - Quantity per pack: 100

6451 5 035-00

Red marking cap - Quantity per pack: 20

6462 2 101-01

One-pair Monitoring test cord with two banana plugs (1-foot cord)

6648 2 900-01

One-pair Look-both-ways test cord with four banana plugs (1-foot cord)

6648 2 901-01

Disconnection plugs, green - Quantity per pack: 20

6462 2 097-20

See ADC literature #103789AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

471

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions

HighBand 10 blocks meet TIA/EIA Category 5e


component specifications, resulting in increased
throughput for DSL and other broadband
applications.

OmniReach FTTN Solutions

Next Gen Network Solutions

Features

50 pair

Telcordia approved ComProtect protection


modules safeguard valuable cable plant and
equipment from voltage surges and spikes
Lockable metal enclosure with Telco override
cover and a splicing chamber with the choice
of either
710 or MS2 splice connectors
LSA-PLUS cross connect field and protection
field combined for High-Density Solution
Lightweight, compact and removable top to
enable stacking units
Instructions, template and mounting
hardware included to mount the terminal
directly to a wall
100 pair

Reduced size over traditional BET footprint for


tight to fit spaces

Applications

Compliances

Primary protection at commercial and MDU


demarcation points

UL 497 listed
100% compliant with Telcordia GR-937

Primary protection for campus environments


MS2 is a registered trademark of 3M.
UL is a registered trademark of Underwriters Laboratories.
Telcordia is a registered trademark of Telcordia Technologies, Inc.

106612AE

ADCs ComProtect Building Entrance Terminals


provide high-density primary protection at
commercial demarcations and are fully compliant
to UL and Telcordia specifications. These
units can be used in both indoor and outdoor
applications and provide up to 50% space
savings over traditional Building Entrance
Terminals using 5-pin protection.

6/09

Outside Plant Fiber and Copper Solutions

ComProtect Building Entrance Terminals (BET)

See ADC literature #106712AE


www.adc.com

+1-952-938-8080

1-800-366-3891

472

OmniReach FTTN Solutions

ComProtect Building Entrance Terminals (BET)


Ordering Information
Description

Catalog Number

710 splice connector input

6649CP 2 720-00

MS

6649CP 2 760-00

splice connector input

710 splice connector input

6649CP 2 820-00

MS

6649CP 2 860-00

splice connector input

100-pair Indoor/Outdoor
Enclosed building entrance terminal Quantity: 1
710 splice connector input

6649CP 2 920-00

MS

6649CP 2 960-00

splice connector input

ComProtect overvoltage protection modules sold seperately.


Other configurations available; please contact ADC Technical Assistance Center.
MS2 is a registered trademark of 3M.

6/09

See ADC literature #106712AE.


www.adc.com

+1-952-938-8080

1-800-366-3891

473

Outside Plant Fiber and Copper Solutions

50-pair Indoor/Outdoor
Enclosed building entrance terminal Quantity: 1

106612AE

Next Gen Network Solutions

25-pair Indoor/Outdoor
Enclosed building entrance terminal Quantity: 1

OmniReach FTTN Solutions

100-pair 5-pin indoor enclosed


building entrance terminal with doors
closedwith RJ-21X output shown

Features
5-pin protection devices safeguard valuable cable
plant and equipment from voltage surges and
spikes
Lockable metal enclosure with Telco override cover
and a splicing chamber with the choice of either
710 or MS2 splice connectors
5-pin protectors are rated 300 volts
10-pair Series 2 disconnect block output field
provided for cross-connection, look-both-ways
testing and monitoring without removing wires
or protectors

25-pair female Telco (RJ-21X) connectors available


on indoor units
Lightweight, compact and fully stackable
Instructions, template and mounting hardware
included to mount the terminal directly to a wall
UL 497 listed
100% compliant with Telcordia TR-NWT-000937

MS2 is a registered trademark of 3M

106612AE

Next Gen Network Solutions

100-pair indoor enclosed 5-pin building


entrance terminal with doors open

6/09

Outside Plant Fiber and Copper Solutions

Building Entrance Terminals: Enclosed, 5-Pin Protection with KRONE Series 2 Blocks

See ADC literature #101469.


www.adc.com

+1-952-938-8080

1-800-366-3891

474

OmniReach FTTN Solutions

Building Entrance Terminals: Enclosed, 5-Pin Protection with KRONE Series 2 Blocks
Ordering Information
Dimensions
(H x W x D)

Description

Catalog Number

710 splice connector input and RJ-21X


optional output

7.5" x 15.5" x 5.4"


(190.50 mm x 393.7 mm x 137.2 mm)

6649 1 430-09

MS2 splice connector input and RJ-21X


optional output

7.5" x 15.5" x 5.4"


(190.50 mm x 393.7 mm x 137.2 mm)

6649 1 470-09

710 splice connector input

11.35" x 10.65" x 6.08"


(288.29 mm x 270.15 mm x 154.43 mm)

6649 1 720-00

MS2 splice connector input

11.35" x 10.65" x 6.08"


(288.29 mm x 270.15 mm x 154.43 mm)

6649 1 760-00

50-pair indoor enclosed 5-pin building entrance terminal Quantity: 1


710 splice connector input

11.25" x 15.63" x 5.38"


(285.75 mm x 397 mm x 136.65 mm)

6649 1 530-00

MS2 splice connector input

11.25" x 15.63" x 5.38"


(285.75 mm x 397 mm x 136.65 mm)

6649 1 570-00

710 splice connector input and RJ-21X


optional output

11.25" x 15.63" x 5.38"


(285.75 mm x 397 mm x 136.65 mm)

6649 1 530-09

MS2 splice connector input and RJ-21X


optional output

11.25" x 15.63" x 5.38"


(285.75 mm x 397 mm x 136.65 mm)

6649 1 570-09

50-pair outdoor enclosed 5-pin building entrance terminal Quantity: 1


710 splice connector input

13.88" x 19.63" x 6.38"


(352.55 mm x 499 mm x 162 mm)

6649 1 820-00

MS2 splice connector input

13.88" x 19.63" x 6.38"


(352.55 mm x 499 mm x 162 mm)

6649 1 860-00

100-pair indoor enclosed 5-pin building entrance terminal Quantity: 1


710 splice connector input

11.25" x 18.25" x 5.38"


(285.75 mm x 463.55 mm x 136.65 mm)

6649 1 630-00

MS2 splice connector input

11.25" x 18.25" x 5.38"


(285.75 mm x 463.55 mm x 136.65 mm)

6649 1 670-00

710 splice connector input and RJ-21X optional


output

11.25" x 18.25" x 5.38"


(285.75 mm x 463.55 mm x 136.65 mm)

6649 1 630-09

MS2 splice connector input and RJ-21X optional


output

11.25" x 18.25" x 5.38"


(285.75 mm x 463.55 mm x 136.65 mm)

6649 1 670-09

100-pair outdoor enclosed 5-pin building entrance terminal Quantity: 1


710 splice connector input

13.88" x 19.63" x 6.38"


(352.55 mm x 499 mm x 162 mm)

6649 1 920-00

MS2 splice connector input

13.88" x 19.63" x 6.38"


(352.55 mm x 499 mm x 162 mm)

6649 1 960-00

Other configurations available; please contact ADC Technical Assistance Center


MS2 is a registered trademark of 3M

See ADC literature #101469.


www.adc.com

+1-952-938-8080

1-800-366-3891

475

Outside Plant Fiber and Copper Solutions

25-pair outdoor enclosed 5-pin building entrance terminal Quantity: 1

6/09

106612AE

Next Gen Network Solutions

25-pair indoor enclosed 5-pin building entrance terminal Quantity: 1

OmniReach FTTN Solutions

Next Gen Network Solutions

100-pair 5-pin protection only


building entrance terminal
with top and bottom stubs

50-pair 5-pin protection


building entrance terminal

Features
High-density primary protection allows up to
eighteen (double-sided) 100-pair units to be
mounted in a standard 7-foot, 19-inch rack
26 AWG cable stub is provided for splicing to the
incoming 24 AWG cable
Building entrance terminals available with 5-pin
protectors in 25-, 50- and 100-pair units
5-pin protectors are rated 300 volts

Allow look-both-ways testing and monitoring


without removing wires or protection
Numerous labeling options allow comprehensive
marking
Variety of mounting hardware options
UL 497 listed
100% compliant with Telcordia TR-NWT-000937

Telecordia is a registered trademark of Telecordia Technologies, Inc.

106612AE

25-pair 5-pin protection


building entrance terminal

6/09

Outside Plant Fiber and Copper Solutions

Building Entrance Terminals: High-Density, 5-Pin Protection with KRONE Series 2 Blocks

See ADC literature #101469.


www.adc.com

+1-952-938-8080

1-800-366-3891

476

OmniReach FTTN Solutions

6/09

106612AE

100-pair 5-pin protection


building entrance terminal
with bottom entrance stub

Ordering Information
Dimensions
(H x W x D)

Description

Catalog Number

25-pair 5-pin protection building terminal,


bottom entrance stub Quantity: 1

8.75" x 6" x 4.88"


(222.3 mm x 152.4 mm x 123.9 mm)

6649 1 110-01/XX

50-pair 5-pin protection building entrance


terminal, bottom entrance stub Quantity: 1

14" x 6" x 4.88"


(355.6 mm x 152.4 mm x 123.9 mm

6649 1 210-01/XX

100-pair 5-pin protection building entrance


terminal, bottom entrance stub Quantity: 1
5-pin protectors included

19.88" x 6.06" x 4.88"


(505 mm x 153.9 mm x 123.9 mm)

6649 1 310-01/XX

6649 1 313-01/XX

5-pin protectors included; (4) 25-pin Telco


(RJ-21X) connectors mounted on back for fast
installation
100-pair 5-pin protection building entrance
terminal, top entrance stub Quantity: 1

19.88" x 6.06" x 4.88"


(505 mm x 153.9 mm x 123.9 mm)

6649 1 310-03/XX

100-pair 5-pin protection building entrance


terminal, bottom rear entrance stub
Quantity: 1; 5-pin protectors included

19.88" x 6.06" x 4.88"


(505 mm x 153.9 mm x 123.9 mm)

6649 1 310-02/XX

6649 1 313-02/XX

5-pin protectors included; (4) 25-pin Telco


(RJ-21X) connectors mounted on back for
fast installation
100-pair 5-pin protection building entrance
terminal, top rear entrance stub Quantity: 1
100-pair 5-pin protection building entrance
terminal, protection only, bottom and top
stubs Quantity: 1

19.88" x 6.06" x 4.88"


(505 mm x 153.9 mm x 123.9 mm)

6649 1 310-04/XX

10.75" x 6.06" x 2.75"


(2273.1 mm x 153.9 mm x 69.85 mm)

6649 1 316-05/XX

*Replace XX with:
25 = 25'
50 = 50'

See ADC literature #101469.


www.adc.com

+1-952-938-8080

1-800-366-3891

477

Outside Plant Fiber and Copper Solutions

Next Gen Network Solutions