FCQ-D
EPLE05-32 28-09-2005 12:58 Pagina 2
The ceiling mounted 4-way blow cassette is specially designed for use in false ceilings.
The greater part of the unit integrates perfectly with the ceiling. Only the slim
decoration panel remains visible. As their name suggests, these units can discharge
air in any of 4 directions.
These cassettes are the most energy efficient cassettes Daikin has ever developed
moreover they are equipped with a special draught prevention technology
COMFORT
• You have the choice of 3 auto-swing positions for maximum comfort: standard, draught
prevention or ceiling soiling prevention.
Auto swing:
Vertical auto swing automatically moves the flaps up and down to distribute air effectively
throughout the whole room.
• Air flow distribution for ceiling heights up to 4.2m without loss of capacity.
• You have the choice out of 2 fan speeds to select: high or low. A high fan speed provides
maximum reach while a low fan speed minimizes drafts.
• These indoor units are very quiet in operation. The sound levels are as low as 28dB (A),
comparable to rustling leaves.
• Daikin’s special dry programme reduces humidity in the room without variations in
room temperature.
• The indoor unit contains an air filter which removes microscopic particles and dust.
• Since the unit has a low height it fits flush into false ceilings (minimum height of 256mm).
• When the ceiling void is too small, a panel spacer can be used to cover the space
between the ceiling and decoration panel.
• It is possible to shut off one or 2 flaps enabling the unit to be installed in the middle
of the room, in a corner or in a small room.
Closed
An optional branch duct can be connected to the air conditioning.
In this way, it is possible to provide additional air flow for crowded
spaces.
Branched
• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.
• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, gives
greater resistance against acid rain and salt corrosion. Additional resistance is provided
by a rust proof steel sheet on the underside of the unit.
An anti-corrosion heat
exchanger cutaway view
Infrared remote
control (Optional)
Hydrophilic film
Aluminium
Heat exchanger
Corrosion-resistant
Acrylic resin
Wired remote
• The wired remote control provides you with a schedule timer, enabling to program the
control (Optional) air conditioning daily or weekly.
EPLE05-32 28-09-2005 12:58 Pagina 4
ENERGY EFFICIENT
• The internal layout of the indoor unit is specially designed to improve its operating
efficiency, enabling the 4-way blow ceiling mounted cassette to achieve higher energy
efficiency levels than contemporary cassette models.
• Inverter technology
Improved energy efficiency:
The use of integrated inverter control ensures maximum energy efficiency by supplying
only the required heating or cooling load where a standard non inverter unit would supply
maximum load in an on/off regime.
Keeps temperature stable
Smaller
Slow start-up temperature
difference
Large temperature
difference
Improved comfort:
The rapid start up time provided by the inverter increases comfort by reducing the lead
time in obtaining the required indoor temperature. As soon as the required temperature
is reached, the inverter unit continuously scans the room for small changes and adjusts
the room temperature in seconds, thereby increasing comfort once again.
When you go out push When you return, you will be Push the “Home leave
the “Home leave operation” welcomed by a comfortable operation” button again,
button, and the air air-conditioned room. and the air conditioner will
conditioner will adjust adjust capacity to the set
capacity to reach the preset temperature for normal
temperature for “Home operation.
leave operation”.
APPLICATION OPTIONS
• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor).
EPLE05-32 28-09-2005 12:58 Pagina 5
Indoor units:
FCQ71,100,125,140D
EPLE05-32 28-09-2005 12:58 Pagina 6
Accessories
INDOOR UNITS FCQ71D FCQ100D FCQ125D FCQ140D
Decoration panel BYCP125DAW1
Panel spacer KDBP55K160WA
High-efficiency filter 65% (colorimetric method) KAFP556DA80 KAFP556DA160
High-efficiency filter 90% (colorimetric method) KAFP557DA80 KAFP557DA160
Replacement high-efficiency filter 65% (colorimetric method) KAFP552HA80 KAFP552HA160
Replacement high-efficiency filter 90% (colorimetric method) KAFP553HA80 KAFP553HA160
Filter chamber KDDFP55DA160
Long-life filter KAFJ551CA160
Ultra long-life filter KAFP55DA160
Replacement long-life filter KAFJ55KA160H
Fresh air intake Chamber type without T-shape & fan KDDP55DA160
with T-shape, without fan KDDP55DA160K
Direct installation type KDDJ55XA160
Insulation kit for high humidity KDT-55D80 KDT-55D160
Branch duct chamber KDP55DA80 KDP55DA160
Chamber connection kit KKSJ55KA160
Accessories
OUTDOOR UNITS RZQ71B RZQ100B RZQ125B RZQ140B
Central drain plug KKPJ5F180
Refrigerant for twin KHRQ22M20TA8
branch piping for triple - KHRQ127H8
for double twin - - KHRQ22M20TA8 (x3)
Demand adapter kit remote control of sound reduction and power input KRP58M51
Notes:
1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz
2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.
3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.
4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.
6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.
7) The sound power level is an absolute value indicating the "power" which a sound source generates.
EPLE05-32 28-09-2005 12:58 Pagina 8
Daikin’s unique position as a manufacturer Daikin Europe N.V. is approved by LRQA for its “The present leaflet is drawn up by way of information only and
of air conditioning equipment, compressors Quality Management System in accordance with does not constitute an offer binding upon Daikin Europe N.V..
and refrigerants has led to its close involve- the ISO9001 standard. Daikin Europe N.V. has compiled the content of this leaflet to
ment in environmental issues. For several ISO9001 pertains to quality assurance regarding the best of its knowledge. No express or implied warranty is
years Daikin has had the intention to design, development, manufacturing as well as to given for the completeness, accuracy, reliability or fitness for
become a leader in the provision of environ- services related to the product. particular purpose of its content and the products and services
mental friendly products. This challenge presented therein. Specifications are subject to change without
demands the eco design and development prior notice. Daikin Europe N.V. explicitly rejects any liability for
of a wide range of products and an energy any direct or indirect damage, in the broadest sense, arising
management system; which involves energy from or related to the use and/or interpretation of this leaflet.
conservation and reduction of waste. ISO14001 assures an effective environmental man- All content is copyrighted by Daikin Europe N.V..”
agement system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and
to assist in maintaining and improving the quality
Printed on non-chlorinated paper / Printed in Belgium
of the environment.
Daikin products are distributed by:
FCQ35B+RKS35F Buy it 1.4~3.4~3.7 n/a 3.4 2.3 n/a 5.5 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1095.27
FCQ50B+RKS50G Buy it 0.9~5.0~5.6 n/a 5.0 3.3 n/a 7.3 20 3+e 1/4" 1/2" 30 20 -10 12 49 £1220.85
FCQ60B+RKS60F Buy it 0.9~5.7~6.0 n/a 5.7 3.8 n/a 9.3 20 3+e 1/4" 1/2" 30 20 -10 12 53 £1313.67
*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/air-conditioning-for-shops/
Please see the next page for heat pump type prices.
Global Cooling Air Conditioning UK Prices*
Daikin 950mm x 950mm Cassette Type Air Conditioning – HEAT PUMP TYPES
Uk UK Uk
Features Nom cooling Nom heating - - Inter wires - - Max pipe - - - - Price
cool Cool heat
Daikin Inverter Models Heat Pump types T/C S/C Run Max min kg
Min~norm~max Min~norm~max kw Fuse connecting Liquid Suction separation kg out Exc Vat
below kw kw amps level amb in
FCQ35C+RKS35F Buy it 1.4~3.4~3.7 1.4~4.2~5.0 3.4 2.3 3.1 5.5 15 3+e 1/4" 3/8" 25 15 -10 15 37 £1160.80
FCQ50C+RKS50G Buy it 0.9~5.0~5.6 0.9~6.0~7.0 5.0 3.3 4.5 7.3 20 3+e 1/4" 1/2" 30 20 -10 15 49 £1315.90
FCQ60C+RKS60F Buy it 0.9~5.7~6.0 0.9~7.0~8.0 5.7 3.8 5.2 9.3 20 3+e 1/4" 1/2" 30 20 -10 15 53 £1408.70
*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/air-conditioning-for-shops/
If you need any help please call us on 01200 428888 or use Live Chat