You are on page 1of 29

PRODUCT

CATALOGUE
Odour measuring technology
from the leader

2014

Index

1. About Odournet
Welcome to the world of Odournet
Working Groups with Odournet involvement
Odournet - Scopes of accreditation
TO-series labs around the world since 1996
Exemplary of an Olfactometry Laboratory

2
3
4
5
6

2. Odour testing equipment and accessories


Olfactometer TO-series
Perceived odour intensity - acetone
Laboratory accessories
Air supply

7
11
12
17

3. Odour sampling equipment


Sampling devices
Sampling hoods
On site pre dilution
Liquid to gas vaporizer
Sample bags

18
20
22
23
24

4. Software products
TO-series controlling software
Odourmap - odour complaint management
iNose Odour Dispersion Monitoring System

25
26
27

Odournet GmbH
Fraunhoferstr.13
24118 Kiel
Deutschland
Tel.: +49 (0)431-22012-0
Fax: +49 (0)431-22012-17
de@odournet.com
Odournet GmbH Fraunhoferstr.13 24118 Kiel

Dear Madam, dear Sir,


We combine the expertise, experience and innovative
capacity of the two foremost pioneers in developing
modern olfactometry over the past 40 years: ecoma and
Odournet.
Odournet is the world leading supplier for odour
laboratory
technologies
and
odour
measurement
equipment, including olfactometers, sampling tools,
software, calibration services, and more.
Most scientific research papers and applied environmental
olfactometry research of the past 20 years are based on
data obtained using our odour measurement equipment.

Marc Andresen
Welcome to Odournet
from experts for experts

The specially designed, unique technology is used by more than 250 laboratories, research
institutes, universities, and companies world wide. Reliable, high-quality measuring technology
consists primarily of the robust measurement equipment, well-engineered software as well as
customer service and support. At Odournet, these elements interact in perfect harmony. We are
your one-stop provider of odour measurement technology solutions.
Odournet was not only instrumental in standardising olfactometry, and chaired the technical
working group that established the EN 13725 standard, Odournet members were also key players
in all other relevant odour working and standardisation groups since 1993, which is illustrated on
the following page.
Odournet has also pioneered ISO 17025 accreditation. An overview of our current accreditation
scopes can be found in the second next page.
The expertise of our employees gives us the best knowledge to develop the best customised odour
measurement and sampling equipment in the world. Dont miss the chance to benefit from this
knowledge and expertise - Be part of it!
All our products come with a 24 months warranty and the first calibration according to EN
13725 and ISO 17025 after 12 months for free.
We are at your service to set up your professional odour laboratory!
Best regards
Marc Andresen
Head of Consumer Relations Odournet GmbH
Amtsgericht Kiel HRB 13106 KI
Geschftsfhrer:
Bettina Mannebeck
Bjrn Maxeiner
Simon Rtzel-Grnberg

Commerzbank AG
Kto. 0119 942 000 BLZ 21080050
IBAN DE 44210800500119942000
SWIFT-BIC DRESDEFF 210
USt-Idnr. DE 812100460

Working Groups with Odournet involvement


NVN 2820

Air Quality Sensory odour measurement using an olfactometer (Netherlands


Normalisation Institute)

CEN/TC264/WG2
'Olfactometry

EN13725 Air Quality Determination of odour concentration by dynamic


olfactometry with Ton van Harreveld (CEO Odournet Group) as Convenor of CEN
standardisation working group TC264/WG2 Odours

2002 - 2005

NVN 2818: 2005

Writing Dutch standard for hedonic tone measurements

since 2003

VDI 3894 - Requested


continuation of team

Emissions an immissions from animal husbandries - Housing systems and


emissions - Pigs, cattle, poultry, horses

2004 - 2011

VDI 3880

Olfactometry Static sampling

since 2006

CEN/TC 264/WG 27

Air quality - Determination of odour exposure in ambient air by using field inspection

2008 - 2011

ISO/TC 34/SC 12 Sensory


analysis - NEN committee (NL)

Dutch standardisation committee on sensory analysis (general)

since 2008

mirror commitee to
ISO/TC 146/SC 6/WG 14

Determination of odour emissions from building products using test chambers ( ISO
16000-28 and ISO 16000-30)

since 2008

VDI 4302

Sensory testing of indoor air and determination of odour emissions from building
products

2009 - 2013

VDI 3884

Olfactometry - Determination of odour concentration by dynamic olfactometry Supplementary instructions for application of DIN EN 13725

n/a

NF X-43-103

Evolution of field inspection french method, intensity method

n/a

AFNOR comittee on EN-13725

French group discussion about EN 13725 revision

2010 - 2013

VDI 3883

Effects and assessment of odours - Conflict management in air pollution abatement


- Fundamentals and application to ambient odour

since 2010

VDI-WG 3885/1

Odour measurements of liquids

since 2011

VDI 3883-4, NA 134-03-10-08

Neighborhood complaints of odor

since 2012

NEN - odours (geurmetingen)

Dutch standardization committee for odour measurements (general)

since 2012

VDI NA 134-02-01-12

Calculation of plume rise

since 2012

VDI 4221

Quality assurance - Requirements on interlaboratory tests in immission control Requirements on providers of interlaboratory tests

since 2013

NVN 2818

Revision of Dutch standard for hedonic tone measurements

since 2014

VDI 3788 / 2

Environmental meteorology - Odour dispersion modelling - source term


determination via backward modelling -

1993 - 1995
1995 - 2003
2012 - now

Odournet - Scopes of accreditation

Within Odournet we have pioneered ISO 17025 accreditation, obtaining the first
accreditation certificate on 28 September 1993 for our Amsterdam laboratory.
Currently we run 6 laboratories for olfactometry according to EN 13725 under 'testing'
accreditations, in the Netherlands, Spain, Germany, the United Kingdom and France.
Being accredited by European Accreditation Collaboration members implies that our
laboratory and sampling team accreditations are recognised in all EU countries.
For the up-to-date accreditation scopes, please see the table below:

France

Cofrac accreditation n 1-1964.

DAkkS accreditation n D-PL-17433-01 and D-EP-17433-01.


Germany

In addition, Odournet GmbH is an accredited inspection body for performance tests


and interlaboratory tests according to EN 13725 and for the automobile guideline VDA
270.
RVA accreditations K077 and L403.

Netherlands

In addition, our Amsterdam laboratory has a calibration accreditation for calibrating


dilution apparatus (olfactometers) according to EN 13725 and certification of reference
gases of n-butanol and SF6 in nitrogen according to ISO 6143.

ENAC accreditation n 1046/LE2024.


Spain

Odournet SL is also an Authorized Control Body (OCA) in the Balearic Islands


according to Decree 104/2010 of 22 September, for the determination of odours.

UKAS accreditation n 2430. ISO 9001 certification, certificate number CA13725.


United
Kingdom

Odournet UK are also accredited for bioaerosol sampling of stack emissions


in accordance with VDI 4257 Part 2 as per the Environment Agency Technical
Guidance Note M2.

TO-series olfactometer labs around the world since 1996

Germany
Italy
Switzerland
Czech Republic
Spain
Austria
Poland
France
Turkey
England
Belgium
Chile

95
23
8
8
6
7
5
5
5
3
3
3

Hungary
Russia
Denmark
Sweden
Hong Kong
Korea
Mexico
Portugal
Ireland
Australia
Finland
Singapore

3
3
3
3
3
2
2
2
2
2
2
1

Norway
Latvia
Estonia
China
Argentina
Bangladesh
Lithuania
Israel
South Africa
USA

2
1
1
1
1
1
1
1
1
1

Exemplary Floor Plan of an Olfactometry Laboratory

Olfactometer TO8
Article no.: TO810000

The olfactometer TO8 meets all requirements


of a dilution device for olfactometric
measurements according to EN 13725:2003. It
uses a unique and special designed dilution
system for odour samples.
The main application of the TO8 is to measure
odour concentration, providing a full record of
the data obtained, according to EN 13725:2003.
The measurement process is fully automated.
You can also assess hedonic tone or intensity
(VDI 3882).
The compact size and transportability allows
you to measure on site in a mobile laboratory, if
required. This option allows for reducing sample
storage time to a minimum.

Fully automatic, 100 %


compliant to
EN 13725:2003

Most sold olfactometer


worldwide

Unique & special


designed dilution
system
Software includes
project & panel
database

Fastest analysing time,


Fastest setup time

Yes-/No-Method,
Intensity & Hedonic
Tone

Heated dilution system


to prevent
contamination

Mobile & plug and


play technology

Scope of supply:
Filter system
Robust transport box
Heating system to prevent contamination
Full version software:
Dynamic olfactometry and intensity/hedonic tone
on USB stick
5 m compressed air connecting PTFE pipeline
Compressed air connection (8mm external)
50 x 8l bags
Calibration certificate according to ISO 17025

Manufacturer

Odournet GmbH, Germany

Required air supply

115 l/min, oil-free

Dimension
(L x W x H)
a) assembled
b) transport size

a) 650 x 650 x 470 mm


b) 650 x 650 x 270 mm

Dilution range

22 (1:4) - 216 (1:65,536)

Interval steps

Factor 2

Dilution principle

Gas jet pumps and


calibrated precision orifices
for sample dosage

Dilution accuracy

< 5%

Outlet air via active carbon


lter

Response/
setting time

< 0.1 sec

Vent for surplus


diluted odour
Number of panel
members working
simultaneously

Required
sample volume

High concentrations: 1-2 liter


Low concentrations: 6-8 liter

Maximum panel
size
(software setting)

16

Maximum calibration
interval

12 months
(according to
EN 13725:2003)

Analyses time for


one sample
(EN13725:2003)

5 min

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Back to content

Weight: 17 kg

Olfactometer TO9
Article no.: TO890000

All functions and


benefits of the TO8

Fastest analysis (Y/NMethod about 5 min,


D-F-C-Method about 7
min)

Plus Dual-ForcedChoice-Method (D-F-C)

Max. dilution 217

Scope of supply:
The olfactometer TO9 meets all prerequisites
of a dilution device for olfactometric
measurements following EN 13725:2003. Using
the TO9 permits a complete description of an
odour sample.
The TO9 meets all functions and benefits of the
TO8 plus the Dual-Forced-Choice-Method (D-FC). The max. dilution expands to 217 which
allows you to measure higher odour
concentrations.

Filter system
Robust transport box
Heating system to prevent contamination
Full version software:
Dynamic olfactometry and intensity/hedonic tone
on USB stick
5 m compressed air connecting PTFE pipeline
Compressed air connection (8mm external)
50 x 10l bags
Calibration certificate according to ISO 17025

Manufacturer

Odournet GmbH, Germany

Required air supply

D-F-C:180 l/min, oil-free

Dimension
(L x W x H)
a) assembled
b) transport size

a) 650 x 650 x 470 mm


b) 650 x 650 x 270 mm

Dilution range (D-F-C)

2 ( 1:8) - 217 ( 1:131,072)

Interval steps

Factor 2

Dilution principle

Gas jet pumps and


calibrated precision orifices
for sample dosage

Dilution accuracy

< 5%

Response/
setting time

< 0.1 sec

Weight: 18 kg

Vent for surplus


diluted odour

Outlet air via active carbon


lter

Number of panel
members working
simultaneously

Required
sample volume

High concentrations: 2-3 liter


Low concentrations: 8-10 liter

Maximum panel
size
(software setting)

16

Maximum calibration
interval

12 months
(according to
EN 13725:2003)

Analyses time for


one sample
(EN13725:2003)

5 min

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Back to content

Olfactometer TO8-8
Article no.: TO880000

The olfactometer TO8-8 meets all prerequisites


of a dilution device for olfactometric
measurements following EN 13725:2003. Using
the TO8-8 permits a complete description of an
odour sample..
The TO8-8 offers the possibility to work with 8
panel members, allowing a higher accuracy in
the
measurement
results.
The
whole
measurement program is computer controlled
and runs automatically. It includes several
measurement sequences, recovery breaks for
panel members and clean air flushing functions
for the dilution unit.

Yes/No method
according to
EN 13725:2003

Up to 8 panel
members working
simultaneously

No Intensity and
Hedonic Tone

Laboratory use for studies


with high number of panel
members, higher statistic
values

Scope of supply:
Filter system
Robust transport box
Heating system to prevent contamination
Full version software:
Dynamic olfactometry and intensity/hedonic tone
on USB stick
5 m compressed air connecting PTFE pipeline
Compressed air connection (8mm external)
50 x 10l bags
Calibration certificate according to ISO 17025

Manufacturer

Odournet GmbH, Germany

Required air supply

D-F-C:180 l/min, oil-free

Dimension
(L x W x H)
a) assembled
b) transport size

a) 900 x 900 x 470 mm,


b) 650 x 650 x 270 mm

Dilution range (D-F-C)

2 ( 1:8) - 217 ( 1:131,072)

Interval steps

Factor 2

Dilution principle

Gas jet pumps and


calibrated precision orifices
for sample dosage

Dilution accuracy

< 5%

Response/
setting time

< 0.1 sec

Weight: 22 kg

Vent for surplus


diluted odour

Outlet air via active carbon


lter

Number of panel
members working
simultaneously

Required
sample volume

High concentrations: 2-3 liter


Low concentrations: 8-10 liter

Maximum panel
size
(software setting)

16

Maximum calibration
interval

12 months
(according to
EN 13725:2003)

Analyses time for


one sample
(EN13725:2003)

5 min

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Back to content

Olfactometer TO8s
Article no.: TO820000

The olfactometer TO8s meets all prerequisites


of a dilution device for olfactometric
measurements following EN 13725:2003. Using
the TO8s permits a complete description of an
odour sample.
The TO8s meets all functions of the TO8. It is
specially designed for travelling around the
world. This makes it possible to perform
measurements around the world and to
undertake international projects. Weighing only
21 kg (packed in a trolley) it is also permitted on
most flights. The TO8s is the smallest 4-place
olfactometer in the world.

All functions and


benefits of the TO8

Easy to build up in 10
min on site

Extra small and light


olfactometer
(about 9 kg)

Specially designed for


travelling and
measurements on site
in a mobile lab

Scope of supply:
Filter system
Robust transport box
Heating system to prevent contamination
Full version software:
Dynamic olfactometry and intensity/hedonic tone
on USB stick
5 m compressed air connecting PTFE pipeline
Compressed air connection (8mm external)
50 x 8l bags
Calibration certificate according to ISO 17025

Manufacturer

Odournet GmbH, Germany

Required air supply

115 l/min, oil-free

Dimension
(L x W x H)
a) assembled
b) transport size

a) 420 x 420 x 410 mm,


b) 400 x 400 x 220 mm

Dilution range

22 (1:4) - 216 (1:65,536)

Interval steps

Factor 2

Dilution principle

Gas jet pumps and


calibrated precision orifices
for sample dosage

Dilution accuracy

< 5%

Outlet air via active carbon


lter

Response/
setting time

< 0.1 sec

Vent for surplus


diluted odour
Number of panel
members working
simultaneously

Required
sample volume

High concentrations: 1-2 liter


Low concentrations: 6-8 liter

Maximum panel
size
(software setting)

16

Maximum calibration
interval

12 months
(according to
EN 13725:2003)

Analyses time for


one sample
(EN13725:2003)

5 min

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Back to content

Weight: 8.5 kg

10

Acet-ON
Article no.: AC000001

The Acet-ON allows the comparison of the


intensity of a sample with different specified
intensities of the reference substance acetone,
and hence, the determination of the perceived
intensity (pi).
The use of comparative sources ensures that
all panel members evaluate the perceived
intensity based on the same reference scale.
The Acet-ON is fully compliant to the
requirements of the standard ISO 1600028:2012 as well as the guideline VDI 4302
(draft). The device allows the presentation of 6
different acetone concentrations ranging from 0
pi to 15 pi, as well as 1 blank (odourless
compressed air), and makes it easier for the
panel members to assess the perceived
intensity of unknown samples.
The use of CRM gas allows traceability of the
presented concentrations, which results in a
high accuracy of acetone concentrations.
Another advantage of the Acet-ON is the use of
only one nose mask, which allows gas release
only when required meaning room air
contamination is kept to a minimum.

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

425 x 275 x 170 mm,

100% compliant to
ISO 16000-28:2012
and VDI 4302 (draft)

6 different piconcentrations and


1 blank

High accuracy of
acetone concentrations

Compact/transportable

Low room air


contamination

Low gas consumption

The Acet-ON in combination with the


direct sniffing device PureSniff XL

Scope of supply:
1 nose funnel
5 m compressed air connecting PTFE pipeline

Optional:
Filter system
PureSniff XL

Air supply:

3 - 5 bar cleaned compressed


air

Accessories (optional):

External compressor (cleaned


compressed air)
Filter system (three stages)
Test gas (e.g. acetone;
concentration 2500 mg/m3)
PureSniff XL device
Sample bags

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Weight: 4 kg
Dilution principle

Gas jet pumps and


calibrated precision orifices

Volume flow:

0.7 l /sec (pre-set by


manufacturer)

Back to content

11

Direct Sniffing PureSniff XL


Article no.: AC000002

Constant flow

The PureSniff XL allows the standardised


presentation of a sample:
As the operator triggers a volume flow, the
smell sample streams out of the sample bag
and passes through a funnel (diffuser) to the
human nose. That way, each olfactory
tester/examiner gets identical sample air with a
standardised volume flow and a constant
presentation time.
Additionally the PureSniff XL can be used for
indoor air sampling and is fully compliant to the
requirements of the standard ISO 1600028:2012 as well as the guideline VDI 4302
(draft).
The PureSniff XL consists of a sealed tube
made of clear PVC for visual checks.
The scope of supply includes the PureSniff XL,
a diffuser and a separate power-pack. Ready to
use sample bags (60l), with PTFE adapter and
corks can be purchased as additional extras.

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

420 x 425 x 1200 mm

Standardised sample
presentation

100% compliant to
ISO 16000-28:2012
and VDI 4302 (draft)
Easy to use and
connect

PTFE and stainless


steel (EN 13725:2003)

Intensity/hedonic
tone/liking

Direct evaluation of an undiluted sample using


the PureSniff XL

Scope of supply:
PureSniff with 1 cylinder
1 nose funnel
Remote control

Optional:
Sampling function
Power pack

Volume flow

0.7 l /sec (pre-set by


manufacturer)

Air supply

2 5 bar

Power supply

External power supply (12V,


65W max)

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Weight: 12.8 kg
Sample volume

60 l max

Duration of
presentation:

2.5 sec

Back to content

12

Direct Sniffing PureSniff II


Article no.: TO890004

Constant flow

Ready for comparable


tests (Sample A
against Sample B)

Standardised sample
presentation

Easy to use and


connect

PTFE and stainless


steel (EN 13725)

Intensity / hedonic
tone / liking

PureSniff consists of 2 sealed tubes, which can


be provided with sample bags independently of
each other. The device works as follows:
As the operator triggers a volume flow, the
smell sample is pushed out of the sample bag
and passes through a funnel (diffuser) to the
human nose. That way, each olfactory
tester/examiner gets an identical sample with a
standardized volume flow and a constant
provision time.
As default setting, the sample is offered for
about 2.5 sec at a volume flow of 20l/min. Using
an 10l bag filled to approx. 70%, one sample
serves for about 10 presentations. For visual
checks the cylinder is made of clear PVC.

Manufacturer
Dimension
(L x W x H)

Sample volume

Back to content

Direct evaluation of an undiluted sample


using the PureSniff II

Scope of supply:
PureSniff with 2 cylinders
2 nose funnels
Remote control

Duration of presentation

2.5 sec

Volume flow

20 l/min

274 x 430 x 860 mm

Air supply

2 5 bar

Weight: 9 kg

Power supply

External power supply (12V,


65W max)

10 l maximum

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Odournet GmbH, Germany

13

Direct Sniffing PureSniff III


Article no.: TO900001

Constant flow

Ready for tripple


testing (Sample A vs
Sample B vs Sample C)

Standardised sample
presentation

Easy to use and


connect

PTFE and stainless


steel (EN 13725)

Intensity / hedonic
tone / liking

PureSniff III consists of 3 sealed tubes, which


can
be
provided
with
sample
bags
independently of each other. The device works
as follows:
As the operator triggers a volume flow, the
smell sample is pushed out of the sample bag
and passes through a funnel (diffuser) to the
human nose. That way, each olfactory
tester/examiner gets an identical sample with a
standardized volume flow and a constant
provision time.
As default setting, the sample is offered for
about 2.5 sec at a volume flow of 20l/min. Using
an 10l bag filled to approx. 70%, one sample
serves for about 10 presentations. For visual
checks the cylinder is made of clear PVC.

Manufacturer
Dimension
(L x W x H)

Sample volume

Back to content

Direct evaluation of an undiluted sample using


the PureSniff III

Scope of supply:
PureSniff with 3 cylinders
3 nose funnels
Remote control

Duration of presentation

2.5 sec

Volume flow

20 l/min

Air supply

2 5 bar

Weight: 12 kg

Power supply

External power supply (12V,


65W max)

10 l maximum

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Odournet GmbH, Germany


275 x 660 x 860 mm

14

Pre Dilution Device EPD


Article no.: EPD10000

The EPD is an easy to use pre-dilution system


for highly-concentrated odour samples. It has
been developed to increase the measuring
range at high odorant concentrations for
olfactometers.
In addition, it protects the olfactometer from
self-contamination.
The EPD is designed for use in olfactometry
laboratories and gives the operator the
opportunity, together with a TO-series
olfactometer, to process odour samples with a
concentration of up to 6 x 106 OUE/m3 with just
one additional mixing process.
Due to the dilution, which precedes the
olfactometric measurement, virtually all known
odour emissions from environmental protection
and industrial markets can be olfactometrically
measured.

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

45 x 105 x 250 mm,

Manual pre dilution


system for laboratory
use
Portable

Pre-set dilutions 1:10


and 1:100

Low noise level

Fast pre dilution

PTFE and stainless


steel (EN 13725:2003)

Low air and sample


consumption

Easy to use and


connect

Scope of supply:
2 x 3m compressed air connecting PTFE pipeline
1 T-unit 8 mm

Optional:
Sample bag (8 l) with PTFE adapter and PTFE
sealings.
Underpressure sampling device (20,000 Pa).

Standard deviation of
the dilutions

< 5%

Response time

<1s

Set-up time

<1s

Maintenance interval

12 months (according to
EN 13725:2003)

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Weight: 2kg
Dilution principle

Gas jet pumps

Control
mechanism of
volumetric ow

Gas jet pumps

Dilution ranges

Standard: 1:10/1:100, 1:2


to 1:200 also possible

Back to content

15

Filter System
Article no.: F0010000

The filter system consists of a PCA tube


(Makrolon) with a stainless steel lid and base.
This unit is available with four feet for mobile
application or with a wall bracket for use in
laboratories. The lter system connects an oilfree compressor or a bottle of compressed gas
and the olfactometer. It is lled with silica gel
(3), activated carbon (4), lter cotton (5) and a
microne lter (6) for the separation of moisture,
organic compounds and dust. The aim is to
achieve uncontaminated reference-air / zero-air.
The inlet (2) and outlet (7) for the air are 8 mm
compressed air quick connectors.
The system has been tested to 5 bar. The
pressure limit valve (1) limits the working
pressure of the TO series olfactometer to 4 bar
which secures the system.

Portable

Connection via oil free


compressor or
compressed gas
possible

Easy to use

Separation of
moisture, organic
compounds and dust

Scope of supply:
Filter System
3 m PA tube 8x6x1
2 m PTFE tube 8x6x1
1 pressurized air gun
1 T-unit 8 mm

Optional:
Filter material exchange set

Silica gel, activated carbon,


cotton, micro-ne lter

Weight: 4 kg

Maintenance interval

Depending on supply air

max. 5 bar, pressure limit


valve

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Odournet GmbH, Germany

Dimension
(L x W x H)

510 x 340 x 135 mm

Back to content

Low maintenance

Filling materials

Manufacturer

Pressure

Filter system for


laboratory use

16

Compressors
Article no.: Z0020038

Compressors for TOseries olfactometer

For running an olfactometry laboratory an oilfree compressor is necessary to provide


pressurized air to the olfactometer.
Odournet offers medical air compressors for
the olfactometers of the TO-series.

Type

Volt/Ph

dB (A)

m/h

bar

l/min

Watt

Kg

Olfactometer

Dr. Sonic 32050V-ES-3

230/1

62

14

8.2

235

2200

72

TO8, TO8s,
TO9, TO8-8

Back to content

17

Sampling Device CSD30


Article no.: CSD10000

The CSD30 is a sampling device for collecting


air (odour) grab samples in sampling bags, with
a default sampling duration of 30 minutes.
Using the lung principle, the sample flows into
the bag through the sampling tube only, without
passing through pumps or other equipment. The
materials used for wetted parts being in
contact with the sample flow are PTFE and
stainless steel, in compliance with EN 13725.
The sample flow is regulated using a calibrated
nozzle integrated in the sampling device. Other
nozzles, flows and filling times are available
upon request. The sampling rate is independent
of the static pressure conditions at the sampling
point if the pressure difference is less than 150
mbar. The sampling flow is closed automatically
once the bag is full. Alternatively, the user can
select a shorter sampling duration using a
countdown timer. The CSD30 sampling device
operates from its integrated rechargeable
NiCd and battery does not require an AC power
connection. The CSD30 unit is robust, and is
easily operated by a technician.

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

700 x 190 x 260 mm

Weight: 4.8 kg

Sample volume
(bag size)

Back to content

Micro processor
controlled pump, flow
controlled by orifice
disc

Easily portable

5 min, 10 min, 15 min or


30 min continuous
sampling

Stops automatically

VDI 3880 and


EN 13725 compliant

High quality
rechargeable batteries
for about 16 x 30 min
samples

Scope of supply:
Calibrated nozzle for 30-minutes sampling
Battery charger
PTFE flexible probe tube 2 m
Countdown timer
5 x 10l sample bags

Accessories (optional):
Stainless steel probe
Calibrated nozzle for different volumetric flows
(i.e. filling times)
Sample bags 10l

Filling time

30, 15, 10 or 5 minutes

Suction pressure

50 mbar

Battery NiCd

6V 5Ah

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

10 litres

18

Sampling Device Standard


Article no.: S0010000

The Sampling Device Standard consists of a


vacuum container, which is evacuated by a
vacuum pump. The sampling point and the
standard sampler are connected by a probe.
Due to the evacuation in the sampling device,
the sample bag, inside the device, sucks in
sample air via the probe. During this process,
none of its components come into contact with
the sample air due to the construction of the
sampling device.
The range of application of the Sampling Device
Standard is, at pressure conditions of
150
mbar, at the peak of the probe (in the air flow
cross section). The filling time of an 10 litre bag
is 30 to 60 seconds depending on the pressure
conditions. The cylinder is made of transparent
PVC in order to aid the optical check of the
filling and the condition of the probe.
The Sampling Device Standard is robust, light
and easy to use. Due to its battery-operation the
sampling pump can be used independently of
the power supply.

Quick, short sampling

Easy to use

Easily portable

High quality
rechargeable batteries

Scope of supply:
Charger
PTFE probe tube 2 m

Accessories (optional):
10 litre sample bags

Maximum vacuum
output

300 mbar

Recommended range of
application

+/- 150 mbar

Weight: 4.5 kg
Sample volume
(bag size)

10 litres

Lead-gel batteries

2x6V

Warranty
Filling time

30 60 s

24 months (warranty extension


up to 5 years through service
contracts possible)

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

730 x 160 x mm

Back to content

19

Ventilated Sampling Hood


Article no.: BPH10000

For sampling on solid


or liquid surfaces

VDI 3880 and


EN 13725 compliant

Light and easy to use

High quality batteries,


for about
6 samples/charge

CSD30 mountable

The ventilated sampling hood supplements the


30-minute sampling system CSD 30 and is
primarily used for sampling non-ventilated,
odour emitting solid or liquid area sources.
When sampling liquids, floats are attached at
the sides of the hood. The system consists of a
hood, which is automatically ventilated by two
radial fans with a constant volumetric flow. The
inlet fan sucks in outside air via an
exchangeable orifice and transports the air from
the top into a corner of the hood via an active
carbon filter. From there the air is
distributed across the whole surface of the
hood, it absorbs the emitted odourants, and is
extracted to the opposite corner by the second
radial fan via another exchangeable orifice with
the same volumetric flow. The sample for
olfactometer tests (primarily using the CSD 30
sampling system) is taken from the suction
nozzles. The same volumetric flow is provided
on the inlet side and the suction side.

Scope of supply:
Ventilated sampling hood
Floater for liquid surfaces
High-quality Lithium polymer battery
Charger power pack for use on 230V connections
Connection cables
Remote control

Optional:
Sampling device CSD30

Manufacturer

Odournet GmbH, Germany

Flow approx. [m/(mx


h)]

30 / 15 / 7.5

Dimensions
L / W / H [mm]

Ready for use approx.


1030 / 530 / 250

Power supply

Lithium polymer battery 11.1 V,


5.5 Ah with a
special charger

Weight

Depending on the design


approx. 10 to 13 kg

Sampling time with


CSD30

30, 15, 10 or 5 minutes

Material

Al Mg 3 19 chromatised

Power consumption

Approx. 1 A

Adjusting the
volumetric flow

Exchangeable orifice on
the suction side at the inlet
and suction fan

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

Back to content

20

Non Ventilated Sampling Hood


Article no.: UBH10000

For sampling on
ventilated surfaces
e.g. biofilter

VDI 3880 and


EN 13725 compliant

Dismountable

This hood allows defined sampling on flow area


sources with very low discharge speeds (e.g.
bio filter, ventilated compost clamp).
The volume of the exhaust air flow is guided
through the hood and the chimney, and is
consolidated. A wind collar reduces the
susceptibility to side-winds at the chimney
outlet and thereby keeps the flow conditions in
the chimney constant. The sampling hood has a
base surface area of 1m2 and a chimney with a
diameter of
150 mm. Due to the surface ratio between the
hood base surface and the chimney cross
section no relevant dynamic pressure is
exerted when the hood is applied. The chimney
can be disassembled from the body of the hood
by loosening the four knurled nuts. There are
carry handles on the body of the hood, so that it
can be transported easily. As the susceptibility
of the sampling hood to side-winds is
particularly a problem at the chimney outlet, a
wind collar is used here which shields it from
the wind and thereby keeps the ow conditions
in the hood constant.

Manufacturer

Odournet GmbH, Germany

Base surface

1 m

Length

100 cm

Width

Back to content

100 cm

Scope of supply:
Hood made of aluminum (1m2 with carry
handles)
Chimney 150 mm with wind collar

Optional:
Cover plate with sampling connection for
measuring saturation concentrations on
passive sources rubber skirting running round
the base of the hood

Diameter of the chimney

150 cm

Total height of the hood:

165 cm

Weight

8 kg

Material

Al Mg 3 19 chromatised

Warranty

24 months (warranty extension


up to 5 years through service
contracts possible)

21

On Site Pre Dilution Device GSP


Article no.: Z0020022

Pre dilution at the


source

VDI 3880 compliant

Avoid losses due to


condensation

Incl. a Prandtl tube for


air speed monitoring

The GSP can supplement the sampling system


CSD 30 and dilutes the sample directly at the
sampling point. Here the pre-dilution can be
performed with nitrogen or synthetic air, whereby
the pre-dilution ratio is xed by the manufacturer
(standard 1:10 with individual calibration data).
The pre-dilution ratio can, however, be set to
different exhaust air conditions on request by
exchanging a sapphire screen accessible from the
outside (e.g. dilution 1:5 or 1:20).
The pre-dilution system provides the sample air
flow with a constant supply of nitrogen (N2) or
synthetic air directly into the tip of the sampling
probe. The moist-warm sample is thereby diluted
immediately at the point of extraction with dry N2
or synthetic air so that when it cools down to the
transportation and laboratory temperature no
condensation forms in the probe, in the tube or in
the sample bag. As a result, no additional heating
is necessary.
Furthermore the GSP has a built-in particle filter to
protect against contamination as well as a micro
Prandtl tube, which can be used to monitor the
process.

Scope of supply:
Stainless steel pre-dilution probe,
with sapphire screen for approx. 1:10
Two-level bottle pressure reducer
Connection tubes
Calibration datasheet

The following is required:


N2, compressed air cylinder
Sampling device

Accessories (optional):
Additional sapphire screens for different
dilution ratios of approx. 1:5 or 1:20

Nitrogen or synthetic air

Two-level bottle pressure


reducer

1800/150/30, can be
expanded by 800 mm
using an extension probe

N2 or synthetic air
consumption

prox. 100l/h

Weight

1.5 kg

Sampling time with


CSD30

30 or 10 minutes

Control
mechanism of the
volume flow

Gas jet pumps

Pressure at the
sampling point

-200 hPa bis +40 hPa


240 C

Sample air

Calibrated sapphire screen

Max. Temperature at
the sampling point
Warranty

24 months

Manufacturer

Odournet GmbH, Germany

Dimensions
L / W / H [mm]

Back to content

22

Liquid to gas vaporizer - LiGaVa


Article no.: PM000182

Determine the
detection threshold

Learn how your


fragrance is perceived

Optimise your
substance-perceptionratio (linear vs.
logarithmical scale)

Compare fragrances
Optimise your formula

Determine the
molecular profile

The LiGaVa system vaporizes any kind of liquid


into the gas phase. Since time, volume stream,

Scope of supply

temperature, as well as the amount of liquid, are


all known variables, it is a highly standardized
sampling system. A set volume of the liquid

1 x LiGaVa incl.:
1 x Temperature control unit
1 x Vaporization unit (heat ing block)

sample is injected into the LiGaVa, which is


designed to vaporise the sample. In order to

Accessories:

achieve the correct vapour pressure for your


particular

liquid

sample,

the

evaporation

temperature can be individually set (up to

Heating power supply


Sample bags made of Nalophane
Additional heating blocks

220C). As the gas is formed it streams into a


connected sample bag at a constant volume flow
rate. The liquid has now been transferred into
gaseous form ready for various analyses:

Odour concentration

Odour intensity & Liking

Molecular Profile

Manufacturer

Odournet GmbH, Germany

Dimension
(L x W x H)

Control unit: 350mm x 150mm x


260mm (without grip)
Heating block: 120mm x 120mm
x 80mm

Adjustable
temperature range

Back to content

5C above room temperature to


220C

Air supply

3-5 bar clean compressed


air

Volume flow outlet

75 l/h

Power supply

230V DC

Weight

Control unit: ca. 4kg


Heating block: ca. 2kg

Warranty

24 months (warranty
extension up to 5 years
through service contracts
possible)

23

Sample bags

Ready to use bags

Material: Nalophan

Special sizes at request

Sample bags have been designed especially


to respond to the quality requirements of
EN 13725:2003, to minimize the risk of
contamination of odour samples. The bags
have an approximate capacity of 8l, 10l, 40l or
60l depending which sampling device is used.

Type

Amount

Connectors

Sealings

Sampling Device

Article no.

8 litre bags

5, 10, 25,
50, 100

PTFE

PTFE

Sampling Device
Standard (model
until 2014)

Z0020003

10 litre bags

5, 10, 25,
50, 100

PTFE

PTFE

CSD30, Sampling
Device Standard
(model since 2014)

Z0020004

40 litre bags

5, 10, 25,
50

Swagelock

Swagelock

Vessel

ON000015

60 litre bags

5, 10, 25,
50

PTFE

PTFE

PureSniff XL
sampling function

Z0020039

Back to content

24

TO-series controlling software


Article no.: SW000002

Direct control of
hardware and
measurement
procedure
Storage and calculation
of results

Panel management up
to 16 databases for
different reference
materials
Upgrade for Intensity
and Hedonic Tone

Interaction and
collection of data from
panel members

Fully EN 13725
compliant

Running with TO7, TO8,


TO9, TO8-8, TO8s

The control software offers easy, intuitive operation.


Integrated test routines check the correct functioning of
your olfactometer. A comfortable tester management
system provides extensive functions to manage the
applied testers as per EN 13725:2003.
The archiving of the measuring data produced such as
n-butanol allows the quality control of your measuring
results. The creation of additional databases for
reference substance checks is possible with up to 16
databases. The detailed recording and evaluation of
your measurement results corresponds to all the
requirements of EN 13725:2003.
This also includes the requirements of the accreditation
process as per ISO/IEC 17025:2005 on the
documentation of the raw data collected including the
saving of data which is not used for the calculation of the
end result (Discarding passages).
In order to guarantee the fastest possible support in
case of defects, the software provides automatic error
reports.
The software supports the measurement of individual
samples by up to 16 testers in 4 teams. Measurements
already completed can be continued at any time.

Processor

Pentium III+

System memory

128 MB RAM

Available hard disc


space

10 MB

Connecting via

USB

Back to content

Scope of supply:
USB stick with software (odour threshold
measurement)

Accessories (not supplied):


Plug-in for intensity and hedonics
USB cable

USB port

Windows based
operating system

Windows 2000 / XP / Vista /


Windows 7

TO series olfactometer

TO8 / TO8-S / TO8-8 / TO9

25

Odourmap Web-based Tool for Odour Complaint Management


Article no.: OMP00001

Communication and
complaints
management tool

Integrates site based


data with community
observations

Promotes engagement
between operators,
regulators and citizens

Historic analysis and


visualisation of odour
events

Complaint validation
and prediction of
future impact risk

Expandable according
to client requirements

Operator of platform
retains full access control

Odourmap is an innovative communication


platform on which plant operators, citizens and
authorities can be equally integrated into the
odour management process. Odourmap
records and visualises a variety of data that is
relevant for dealing with odour problems and
citizen complaints, providing a multilateral,
easy-to-use platform, where all parties involved
can access the information relevant to them.
Watching our Explainer Film you can discover
Odourmap and its benefits in just 90 seconds.

Online Citizen Monitoring

Collection and registration of citizen observations and complaints

Smartphone App

Collection and registration of citizen observations and complaints

Grid Inspections

Data input from systematic Grid Inspections using citizen panels, professional
observers (according to VDI 3940 Part 2) or facility site staff.

Meteo Data

Online display of current Meteo Data and optionally also the modelled current
impact caused by known, regulated emission sources. This can help in plausibility
checks of observations, and in assigning observations to the most plausible source
under the current wind flow conditions.

Facility Module

Mapping of odour sources, the setting of facility-specific odour types, the


assessment of the odour potential of odour sources and the input of limit values. In
addition, the contact details of facility operators can be registered.

Odourmap is designed to also integrate other data streams like dispersion modelling as well as sensor
data (e-noses) and emission data and odour critical operational data.
As a modular platform Odourmap is continually being enhanced and the range of features extended.
For further details and a guided Odourmap tour in a TeamViewer Live Presentation to experience the
overall look and feel of Odourmap and its easy-to-use functions and features at first hand, please contact
Marc Andresen (T: +49 431 22012-14; E: mandresen@odournet.com ).

Back to content

26

iNose Odour Dispersion Monitoring System


Article no.: GRD00048

Real-time display of
emissions

Reliable data for


complaint validation

Display of effects of
adjustments in the
operation process

Always up-to-date.
Easy and fast in use.

Immediate response
to changes in current
meteorological data
and weather forecasts

Little to no
maintenance.
Accessible from
anywhere at any time.

iNose offers a complete solution to odour


control:
iNose provides a clear insight into the
dispersion of gas and odour based on current
and reliable weather data. That way iNose
allows operators to plan production or to adjust
production settings based on the (forthcoming)
meteorological circumstances.
This prevents discontent and improves the
relationship with the surrounding community.

Prevent penalties or even recall of permit to operate and favourable position when negotiating new permits.
Minimize chances of complaints and thus improved relation with the immediate surroundings by building good
reputation and image.
Validate complaints.

Benfit from the automatic alert management in case of (future) excessive emissions.

iNose automatically imports the most current meteorological data from the database administered by the
leading MeteoGroup Europe. The most common dispersion computer model 'Plume' calculates the
dispersions. Google Maps provides maps and satellite images from various providers. The substance
properties are taken from our Odournet library of Odour Thresholds, based on extensive literature review
and on in-house odour thresholds gained from thousands of studies in all odour relevant sectors in the
past 30 years, or may be determined by our environmental consultants at your site.
With iNose, a company can obtain a clear insight into their (future) odour and gas dispersion over the
surroundings. This is made possible by the permanent connection with the most current weather
forecasts and readings.

Back to content

27

Sensory Expertise delivered worldwide

The ODOURNET Group

Odournet GmbH Fraunhoferstr. 13 24118 Kiel Germany T +49 431 22012-0 F +49 431 22012-17
sales@odournet.com www.odournet.com