Liebert

Hipulse UPS System


TECHNICAL SPECIFICATION
Hipulse UPS System
Nominal Rating (0.8 pf)
Physical characteristics
Width (mm)
Depth (mm)
Height (mm)
Weight (kg)
Input
Voltage
Frequency
Power factor
Output
Voltage
Voltage stability
- steady state
- 100% load step
Frequency
Frequency stability
- synchronised
with the bypass supply
- auto-synchronised
Overload capacity
from inverter
@ nominal voltage
- 3 Ph
- 1 Ph
Short circuit current
from inverter
- 3 Ph
- 1 Ph
Voltage distortion with linear
load
Voltage distortion with 100%
non-linear load
Max. deliverable power
with non-linear load
(CF = 3:1)
Max. unbalanced load
Voltage displacement with
100% unbalanced load
Output voltage dissymmetry
with 100% unbalanced load
Standards and approvals
Safety / EMC / Design
European directives
73/23/EEC and 89/336/EEC

80kVA

120kVA

160kVA

200kVA

900
840
1900
750

1250
840
1900
1000

1250
840
1900
1200

1250
840
1900
1350

380 / 400 / 415V 3Ph +10 / -15%


50 or 60 Hz 5%
0.94 with optional filter
380 / 400 / 415 V 3Ph + neutral
1%
5%
50 or 60 Hz

1 Hz
0.1 Hz

110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute


200% for 30 seconds

1.5 In for 5 seconds (in accordance with EN 50091-1-1)


2.9 In for 5 seconds (in accordance with EN 50091-1-1)
< 1%

<3% Ph / Ph, < 5% Ph / N

100%
100%
120 1 el
2%
CEI EN 50091-1-1/ EN 50091-2 / ENV 50091-3
CE mark

BS EN ISO 9001:1994

L I E B E R T C O R P O R AT I O N

LIEBERT EUROPE

1050 DEARBORN DRIVE


P.O. BOX 29186
COLUMBUS, OHIO 43229
USA
TEL: +1 614 888 0246
FAX: +1 614 841 6022

VIA G. ROSSINI 6
20098 S. GIULIANO MILANESE
MILANO
TEL: +39 02 982501
FAX: +39 02 9844633

FM 00722

HIPULSE UPS SYSTEM AND OTHER LIEBERT POWER


PROTECTION PRODUCTS ARE AVAILABLE FROM:

LIEBERT WEB SITE


While every precaution has been taken to ensure accuracy and completeness in this
brochure, Liebert Corporation assumes no responsibility, and disclaims all liability for
damages resulting from use of this information or for any errors or omissions.
1999 Liebert Corporation. All rights reserved throughout the world.
Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.
SLE HPI E.1

Printed in Italy

http://www.liebert.com

LIEBERT UK
GLOBE PARK
MARLOW
BUCKINGHAMSHIRE SL7 1YG
UNITED KINGDOM
TEL: +44 (0) 1628 403200
FAX: +44 (0) 1628 403294

POWER PROTECTION

Liebert

Hipulse UPS System

80-200 kVA

HIPULSE
UPS SYSTEM:
THE BEST PROTECTION
FOR YOUR CRITICAL LOAD
High reliability IGBT inverter
Available with 6 or 12 pulse rectifier
Paralleling of up to six units using
either modular or centralised static
bypass switch
High efficiency EcoMode
Advanced battery management
Backfeed protection
Battery ground fault warning
Frequency converter 50/60Hz with or
without battery
SNMP network compatible with
dynamic monitoring
BMS connectivity through either
Modbus, JBus or PROFIBUS
Many other optional features to suit
your power needs

NE
W

THREE PHASE ON-LINE UPS


FOR DATA CENTRES,
TELECOMMUNICATIONS AND
INDUSTRIAL APPLICATIONS

I E B E R T

O R P O R A T I O N

POWER PROTECTION

CAN YOU BE CERTAIN OF YOUR


POWER SUPPLY?
An increasing demand is being placed on data
processing speeds, real time interconnection of
telecommunications systems and the need to

OUTAGES
Typically described as a 'zero-volt condition lasting
longer than a half-cycle', outages can be caused by mains
equipment failure, accidents, lightning, operation of
protective devices, etc. The result: system crashes and
hardware failure.

provide continuous and automated processing


systems. While providing a wealth of
opportunity such enhancements have imposed
greater demand on the availability of their
electrical power supply.
Even though electrical power is generated with a

SPIKES/TRANSIENTS
Spikes are a brief intense surge, less than half a cycle in
duration, but with voltages 100% or more above normal.
Transients cause data corruption, processing errors,
incorrect data transfer, keyboard/ mouse/ monitor lockups and hardware damage.

virtually perfect voltage waveform, this is far


from perfect when it reaches the user. Many
forms of disturbance cannot be tolerated, e.g.

WAVEFORM DISTORTION

outages and frequency variations, which could

Waveform distortions that occur at a natural


multiple of the standard power wave are called
harmonics. While harmonics can be triggered by
equipment inside the network, mains power may
contain harmonics generated hundreds of miles
away.

result in irreparable loss through a combination


of equipment damage and the loss of equipment
availability. Of course the financial implications
of the latter can be enormous, affecting both
existing operations and more importantly future
business.
For mission critical processes the only effective
solution is an on-line UPS capable of handling all

FREQUENCY VARIATIONS
Rare in mains power, frequency variations are most
common with back-up power systems such as standby
generators. Off-Line and Line-Interactive models, even
some On-Line UPS, cannot handle frequency problems,
which can cause system crashes and equipment
damage.

of the power problems identified opposite.


NOISE
Often generated by normal computer operation, noise
triggers a range of problems including incorrect data
transfer, printing errors, keyboard/mouse/monitor lockups, program crashes, data corruption, even damage to
computer power supplies.

SAGS
These short term, low voltage brownouts are triggered
by the startup of large loads, mains switching etc. In
addition to causing system crashes, sags can damage
hardware.

SURGES/SWELLS
With voltages above 110% of normal, surges can be
triggered by rapid reduction in power requirements, due
to large loads being turned off, or by mains switching.
The result: hardware damage.

I E B E R T

O R P O R A T I O N

LIEBERT HIPULSE UPS


FOR SYSTEM WIDE PROTECTION
No matter what equipment you are using, if continuity of use
is imperative, then security of the electrical power supply
should be provided by a Liebert Hipulse UPS system. It will
solve all your power disturbance problems, and when
complemented by other Liebert power products, e.g.
transient voltage surge suppressors, static bus transfer
switches, and other load bus reliability solutions, the Hipulse
UPS provides the best solution to achieving fault tolerant
power supplies.
Designed to support critical loads, the Hipulse space-saving
design can fit in to most environments and will satisfy
acceptable noise requirements. As a static UPS system, the
Hipulse is an excellent choice for supplying unbalanced loads,
and its performance for supplying non-linear loads is
unsurpassed in the UPS industry. It is capable of providing
conditioned power instantly to the continually changing, even
transient levels of power demand common with most
networks and industrial operations.
DESIGNED TO PROTECT CRITICAL SYSTEMS IN A
VARIETY OF KEY APPLICATIONS
Mainframe and super-mini computer systems
Telecommunication centres
Major LAN and WAN critical systems
Data centres, including RAID arrays
Test and laboratory installations
Industrial process and control operations.
Medical equipment

I E B E R T

O R P O R A T I O N

POWER PROTECTION

WEALTH OF ADVANCED FEATURES

IGBT Inverter

Small footprint

High frequency IGBT technology offers high

Hipulse is designed to optimise on required

reliability and excellent performance.

installation space while not compromising on


accessibility for routine servicing and

Battery management

maintenance requirements.

The battery in a UPS system plays an important


role in ensuring continuous protection of the

High and consistent efficiency

power supply to critical loads. For this reason the

Hipulse offers a consistently high efficiency of

battery must be maintained under optimum

over 93% while operating in normal mode, and

conditions and ready to operate at any time.

over 97% in EcoMode when the load is supplied

Hipulse offers one of the most advanced battery

via the static bypass switch.

management systems available on the market:


Intelligent battery testing to prove system
availability.
Temperature compensated charging maximising
the lifetime of the battery.
Protection against deep discharge: prevents
battery damage in the event of prolonged
outages at low discharge levels.

Maintenance bypass
Allows routine servicing without interrupting
power to the load, providing safe transfer to and
from the UPS system.

Built to the highest standards


Hipulse is designed and built to meet stringent
requirements for operator safety and low
electromagnetic interference.

I E B E R T

O R P O R A T I O N

ALWAYS IN CONTROL

HIPULSE
MICROPROCESSOR CONTROL
Hipulse UPS System

The Hipulse control panel displays more than 80 items


of data and can be used to program system
parameters during installation. The bargraph indicates
the percentage of load connected to the UPS and,

RS 232

during mains supply failure, shows the back-up time


available from the system.
The liquid crystal display shows, in 6 different
languages, data on input voltage and frequency,
output voltage, current, frequency, real power (kW),
battery voltage and current, internal equipment
temperature and battery temperature.
The power flowchart shows whether the UPS is
operating in the normal mode from the inverter or in

Real time status


information can be
transmitted to a remote
location, such as a Service
Centre via a modem link.
This can dramatically
reduce the need for site
call-outs and so minimise
operating costs.

EcoMode.

RS 232

COMMUNICATIONS
Hipulse features highly advanced communications
with the ability to interface with Ethernet/SNMP for
monitoring in networked environments as well as
providing for facility wide monitoring through BMS

The Service operator can


periodically query the
system to obtain current
operating status and alarm
history.

supported protocols Modbus, JBus and PROFIBUS.


With local or remote connection to a PC, Hipulse
provides fully featured monitoring together with data
history viewing for diagnostic purposes.

Remote
Service Centre

I E B E R T

O R P O R A T I O N

POWER PROTECTION

COMPATIBLE WITH MANY TYPES


OF LOAD AND SYSTEM CONFIGURATION
Non-linear loads

With Central Static Switch

The Hipulse UPS high frequency PWM inverter

Installations with high initial power requirements and

design is particularly suitable for handling

several redundancy levels may be equipped with up

non-linear loads with a crest factor as high as

to six modules with a Central Static Switch and

3:1 without derating, while maintaining

system maintenance bypass. Management software

output voltage distortion to within 3%.

continuously supervises applied load which is safely

To safely cope with heating effects due to

transferred to the mains supply only when the

high harmonic content the neutral is rated at

capacity of the UPS system is exceeded.

1.5 times the phase current.


Bypass
Supply
Unbalanced loads

output voltage balanced to within 2% and


angular displacement of only 1.

High overload and short-circuit


capacity

~~
~~=

others without load), while maintaining the

UPS 2

~~
~~=

loads (one phase at nominal load and the

UPS 1

~=

UPS N

~=

~=

~~
~~=

The system can supply 100% unbalanced

Load

The Hipulse UPS inverter can withstand a


150% overload on three phases and has
excellent fault clearing capability with 290%

Parallel with Distributed Static Switches

phase current available for single phase faults.

The units can be paralleled in two


configurations
With Distributed Static Switches
Up to six modules can be incorporated into a
single UPS system to satisfy additional power
growth requirements or to increase system
redundancy.

~=
~~

~=

connection

UPS 1

UPS 2

UPS N

Bypass
Supply

~= ~=
~~
~~ ~~

~= ~=

Maximum flexibility in parallel

Load
Parallel with Central Static Switch

I E B E R T

O R P O R A T I O N

CONFIGURATIONS TO SUIT ANY


APPLICATION
OPTIONS TO SUIT ANY
APPLICATION

YOU CAN TRUST


THE LIEBERT NAME

Input harmonic reduction filters configured for 6


or 12 pulse rectifiers

Since 1965 Liebert has been an industry leader,

Isolation transformers for rectifier or bypass


supplies
Backfeed protection

renowned world-wide for advanced computer


protection equipment, including UPS, power
conditioning and environmental control systems.
As part of the world-wide Emerson Electric Co,
Liebert is one of the largest suppliers of protection

Remote control and display panel for system wide


monitoring

equipment for telecommunication and computer

Top cable entry

other critical electrical installations, with an

Air filters for installation under harsh


environmental conditions

impressive customer list which includes many

DC ground fault indication

The company places a high priority on using the

installations, clean rooms, high security areas, and

thousands of companies all around the world.

most advanced technology, designed and built to


stringent ISO9000 standards, and continues to
invest heavily in research and development.
All systems are built to make the most efficient use
of energy and to ensure the highest level of
reliability. All our products are backed by the huge
international resources of the Liebert Corporation,
the name you can trust.