TECHNICAL SPECIFICATION

Blower-German make : Backward impeller type


Pre Filter : Synthetic PU washable
Hepa Filter : Efficiency 99.97% @ 0.3 microns
VOC Filter: : Unique blend of activated carbon and alumina
Unit capacity: : 350 CFM

Lab Guard
Mounting: : To be done outside VF Lab on any Wall
Power consumption: : 90 Watts maximum
Filter replacement as per auto indication
Electrical supply : 100/110 volts OR 220/240 volts 50/60 Hz

specifications subject to change without notice

Ordering information
Positive Pressure System
Lab Guard LG 300
Lab Guard LG 300
Spare Filter Set
100 120 Volts 60 Hz order code
220 240 Volts 50 Hz order code
order code
FX
FX
FX
2045
2046
2047
LG 300
Return Blower order code Fx 2048

Dimensions
590 mm 470 mm

800 mm

Traceability calibration in accordance with


C national and international standards, NIST USA
For more details go to
www.shivaniscientific.com

Q Individual and expressive quality control certificate

Shivani Scientific Industries (P) Ltd


26A Raju Industrial Estate, Penkar Pada Road Tel - + 91 22 2845 6768
Near Dahisar Check Naka, Mira-401104 + 91 22 2845 6769
Dist. Thane (Mumbai) Maharashtra, INDIA + 91 22 2845 6770
e-mail sales@shivaniscientific.com Fax - + 91 22 2845 7140
ssipl@bom5.vsnl.net.in + 91 22 2845 6766

Distributor

We make it possible

Lab Guard
Positive Pressure System

Lab Guard
LAB GUARD

Split A/C

Positive Pressure System DESIGN


The LAB+GUARD has been designed with State
IVF LAB
LG 300 of the Art technology using 4 stage filtration
system. The unique filter combination filters out
UTILITY
ROOM
LAB GUARD

air and gas contaminant thus by giving most


suitable air for gametes and embryos.
LAB+GUARD system contains a unique 4 stage
Blower
Return

filtration system containing Prefilter, Hepa Filter


and unique blend of activated carbon and
alumina, which ensures wide variety of Gases,
particular contaminants are oxidized or are
CONCEPT absorbed. The LAB+GUARD has been designed Fresh Air
The LAB+GUARD is developed to improve the to reduce the microbial air flora to the minimum
level.
laboratory air quality making it nearly equal to OPERATING SECURITY RETURN BLOWER
clean air. Thus replenishing and subsequently
nourishing the entire laboratory, making it safe for REDUCES CFU, REDUCES VOC Every care has been taken in designing to make The return blower is utilised to circulate back the
The unique design and the concept of sure that air absorbed is thoroughly cleaned air of IVF lab to room where LAB+GUARD has
the sensitive procedures to be executed. This is
LAB+GUARD positive pressure system not only for contaminants and to reduce bacterial count in been fitted.
achieved by a number of inclusions and their
reduces VOC content in the air but also the CFU IVF Lab. The LAB+GUARD design also facilitates
applications all of which are simple, cost effective
count in the IVF Lab. The LAB+GUARD not introduction of fresh air into the air circuit which UPGRADING, EXPANDING OR
and user friendly.
only protects embryos and gammas but also gives maximum safety from Carbon dioxide
The positive pressure system uses the basic
released into the IVF Lab by CO2 Incubators and
SETTING UP NEW IVF LAB?
principle of “Over Pressure or positive pressure in protects embryologists who is the most affected
otherwise. also it protects embryologists from gas mixtures The LAB+GUARD team helps you in evaluation of
a room which restricts the entry of outside air”.
released on work stations. possibilities to improve air quality in your lab. If
This is achieved by absorbing the circulating air
outside the IVF Lab (Room) and then you are upgrading, expanding or setting up new
subsequently passing the same through a series CHANGE FILTERS AS PER USAGE lab contact us for technical assistance.
of 4 stage filters thus making it quite IVF friendly.
Thus ultimately the effective, circulating air in the The LAB+GUARD also houses a unique
automatic indication system whereby the user is
IVF lab reaches a near clean air status, provides a
informed when to change the filters, and not
WHO BREATHS CO2
positive pressure, reduces the CFU count, IN YOUR IVF LAB ?
eliminates the SPM, VOCs and CACs. “every quarterly”. This feature not only gives
tremendous relief to the user for tracking the If your lab does not have regulated fresh air intake or
stipulated time of change but also saves lot of positive pressure design, there are every chances
ENSURE NET FLOW OUT money.
that your embryologists are breathing out CO2 tanks
In any HVAC/air flow design it is essential that net
flow is going out of the room. This means room air MAINTENANCE emptied ever year. Since CO2 can not be absorbed
volume and pressure should be slightly higher or filtered by Indoor air purifiers or filters. The
The LAB+GUARD has automatic indication for
than adjoining areas/rooms. This will keep out Filter change and the design facilitate extremely LAB+GUARD facilitates introduction of fresh air and
any toxic fumes trying to come in. IVF labs which easy replacement of filters even by non technical reduces the risk of high CO2 concentration into the
are not having adequate positive pressure are staff. Other than filter change it is virtually IVF Lab.
suceptible to risk of contamination. maintenance free.