38HK18-70

38HQ18-24

Condensing Units - 50Hz


1 to 6 Nominal Tons

Product Data
The 38H Series Energy-Efficient Split condensing units incorporate innovative technology to provide
reliable cooling performance. Built into these units are features most desired by the industry.

Features/Benefits
Designed especially for high ambient
environment.
EER (Energy Efficiency Ratio) ratings
of up to 10.0.
The small footprint coupled with the
horizontal airflow design means that the
38H Series units can be installed within
200 mm (8 in). of an outside wall, on a
roof, balcony, or deck.
Electrical Range
All units are offered in 220-240v single
phase. Three-phase units are available
from 048 through 060 sizes in 400v.
Wide Range of Sizes
The 38H Series is available in 7
nominal sizes from 1.5 to 6 Ton to
meet the needs of residential and light
commercial applications.
Application Versatility
The unit can be combined with a wide
variety of evaporator coils and blower
packages to provide quiet, dependable
comfort. Unit can be installed on a roof or
at ground level.
Easy
access
for
service
and
maintenance
A single panel provides immediate
access to the isolated compressor and
control compartment, allowing a service
technician access to check unit operation
without losing condenser airflow. Coils
can be cleaned quickly from the outside.
Secure operation
If security is an issue, outdoor and
indoor units are connected only by
refrigerant piping and wiring to prevent
intruders
from
crawling
through
ductwork. The 38H Series units can be
installed 8 in. away from outside walls,
protecting coils from vandals and severe
weather.

38HK-04 PD 50HZ 2011

38HK/HQ

Fast installation
Carriers compact systems take
only a few hours to install
only wire and piping need to be
run. The fast and easy
installation ensures minimal
disruption to customers in the
home or workplace. This Carrier
advantage
is
especially
beneficial in retrofit situations.
External Service Valves
Service valves are brass,
front seating type. The 38H
Series has flare connections,

sweat adapter kit is provided


for 7/8 tube size. Valves are
externally
located
so
refrigerant tube connections
can be made quickly and
easily. Each valve has a
service port for ease of
checking operating refrigerant
pressures.
Built-in reliability
Carrier split system outdoor
units are designed to provide
years of trouble-free operation.
The 38H Series condensing

units
are
the
only
dedicated commercial units
with all safety features
standard to ensure high
performance and lasting
reliability under the most
demanding situations. For
example, start capacitors
ensure dependable startups, especially during low
voltage conditions (down to
187 v). High-pressure and
low-pressure
safety
switches are standard

Table of contents
Features/Benefits.
ModelNumber Nomenclature..
Physical Data.
Combination Ratings
Air Deflector Accessory
Base Unit Dimensions..
Electrical Data - Controls

Detailed Performance Data 42TX Matching.


Detailed Performance Data FB4A Matching
Detailed Performance Data Ceiling Cassette Matching.
Detailed Performance Data Free Stand Matching...
Typical Wiring Schematic.
Application Data
Appendix Long Line Guide Line.

Page.
1
3
3
4
5
6-7
8
9,10
11,12
13,14
15
16-18
19
20

Model number nomenclature


38 H K C 18 D S 7 0 - 00
Factory Referance

Type
38-Air-Cooled
Condenser
Series

38HK/HQ

Design Series
Voltage
7 220/240-1-50
9 400-3-50

Condenser Type
K-Cool
Q-Heat Pump

Fin Type
S Standard Bare Fins
P Pre-Coated Fins

Compressor
C Reciprocating
R Rotary Super Tropical
S Scroll

Application
D : Ducted application

Nominal Capacity in Tons (kW)

FB4A or 42TX
24 Volt compressor contactor
U : Un Ducted application/Decorative
Ceiling Cassette, Hi wall,-etc
220 Volt compressor contactor

18 1.5 Tons (5.3kW)


24 2 Tons (7 kW)
30 2.5 Tons (8.8kW)
36 3 Tons (10.6 kW)
48 4 Tons (14 kW)
60 5 Tons (17.6 kW)
70 6 Tons (20.6 kW)

Physical Data
UNIT 38H
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
SHIPPING DIMENSIONS (in) (W X H X D)
COMPRESSOR
Cool Only
Heat Pump
REFRIGERANT TYPE
METERING DEVICE
Ducted Application
Un-ducted Application
FINISH
OUTDOOR FAN
RPM/CFM
Diameter, No. Blades
Motor Horsepower,
COIL DATA
Face Area (sq ft)
Tubes
Fins
FPI
REFRIGERANT LINES
Connection Type
Liquid Line
Vapour Line
Max Length
Max Lift
Max Drop
* Sweat adapter kit is provided for 7/8 tube size

18
1.5
123

24
30
2
2.5
139
154
37 x 29.7 x 16.1

36
3
161

48
4.0
211

70
60
6.0
5.0
253
227
50.4 X 40.2 X 30
Scroll

Reciprocating
Rotary

-R22
Nozzle, in the indoor unit
Capillary Tube
Nozzle, in the indoor unit
Gray
Propeller Type
1100/2000
860/3,000
18 in, 3
24 in, 3
1/2
1/12
6.3

Smooth
15

17

5/8 in.

12.05

Helical grooved
Aluminium, Double Wavy
17
12
15
Flare
3/8 inch
3/4 in.
50 ft
30 ft
30 ft

14

7/8 inch*

Combination ratings
38HK/HQ

COOLING ONLY
Nominal
Cap.
MBtuh

18

24

30

36

48

60
70

INDOOR TYPE

INDOOR
MODEL

OUTDOOR
MODEL

Cassette
Cassette
Console
Ducted Split - 42TX
Ducted Split -FB4A
High Wall
High Wall
High Wall
Cassette
Cassette
Console
Ducted Split - 42TX
Ducted Split -FB4A
High Wall
High Wall
High Wall
Cassette
Cassette
Ducted Split - 42TX
Ducted Split -FB4A
High Wall
Cassette
Cassette
Cassette
Cassette
Ducted Split - 42TX
Ducted Split -FB4A
Free Stand
High Wall
Cassette
Cassette
Ducted Split - 42TX
Ducted Split -FB4A
Free Stand
Ducted Split - 42TX
Ducted Split -FB4A
Free Stand
Ducted Split -FB4A

40GKX0187
40KMC0187
42VMC187C
42TX-018-701R
FB4ASSF018
42KPC018703
42KHC0187
42EGC018-7
40GKX0247
40KMC0247
42VMC247C
42TX-024-701R
FB4ASSF024
42KPD024703
42KHD0247
42EGC024-7
40GKX0367
40KMC0367
42TX-030-701R
FB4ASSF030
42XP090C3
40GKX0367
40KMC0367
40GKX0487
40KMC0487
42TX-036-701R
FB4ASSF036
42SM5C
42XP100C3
40GKX0487
40KMC0487
42TX-048-701R
FB4ASSF048
42SD6C
42TX-060-701R
FB4ASSF060
42SD7C
FB4ASSF070

38HKC018US70
38HKC018US70
38HKR018US70
38HKC018DS70
38HKC018DS70
38HKC018US70
38HKC018US70
38HKR018US70
38HKC024US70
38HKC024US70
38HKR024US70
38HKC024DS70
38HKC024DS70
38HKC024US70
38HKC024US70
38HKR024US70
38HKC030US70
38HKC030US70
38HKC030DS70
38HKC030DS70
38HKC030US70
38HKC036US70
38HKC036US70
38HKC036US70
38HKC036US70
38HKC036DS70
38HKC036DS70
38HKC036US70
38HKC036US70
38HKC048US90
38HKC048US90
38HKC048DS90
38HKC048DS90
38HKC048US90
38HKC060DS90
38HKC060DS90
38HKC060US90
38HKS070DS90

AHRI
CAP.
(Btuh)
17700
17700
18000
19400
20000
18000
18000
18000
21700
21700
24000
24900
24300
24000
24000
24000
28600
28600
29500
30100
28500
30900
30900
35100
35100
35000
34500
35000
34000
40700
40700
45000
46000
45000
59000
59000
59000
65700

AHRI*
CFM
425
425
440
650
1150
550
550
550
450
450
530
650
1200
650
650
650
750
750
800
1500
730
750
750
975
975
1100
1500
800
830
975
975
1400
1650
900
1600
1850
1500
2000

TOTAL
(kW)
2.36
2.36
2.25
2.4
2.5
2.2
2.2
2.15
2.89
2.89
2.95
3.1
3.1
3.0
3.0
2.9
3.25
3.25
3.2
3.3
3.1
3.5
3.5
3.7
3.7
4.0
4.0
3.8
3.7
4.2
4.2
4.5
4.6
4.5
6.0
5.9
5.9
6.1

EER
7.5
7.5
8.0
8.1
8.0
8.2
8.2
8.4
7.5
7.5
8.1
8.0
7.8
8.0
8.0
8.3
8.8
8.8
9.2
9.1
9.2
9.0
9.0
9.5
9.5
8.8
8.6
9.2
9.2
9.7
9.7
10.0
10.0
10.0
9.8
10.0
10.0
10.8

HEAT PUMP
COOLING MODE
Nominal
Cap.
MBtuh

18

24

INDOOR
MODEL

OUTDOOR
MODEL

AHRI
CAP.
(Btuh)

AHRI*
EER
CFM

kW

AHRI
CAP.
(Btuh)

AHRI*
CFM

High Wall
High Wall
High Wall
High Wall
High Wall
High Wall

42QPC018703
42QHC0187
42EGQ018-7
42QPD022703
42QHD024-7
42EGQ024-7

38HQR018US70
38HQR018US70
38HQR018US70
38HQR024US70
38HQR024US70
38HQR024US70

18000
18000
18000
24000
24000
24000

550
550
550
650
650
650

2.2
2.2
2.2
2.95
2.95
2.95

18000
18000
18000
24000
24000
24000

550
550
550
650
650
650

LEGEND
CFM Cubic Feet Per Minute
EER Energy Efficiency Ratio
* Air Conditioning, Heating and Refrigeration Institute.

HEATING MODE

INDOOR
TYPE

8.2
8.2
8.2
8.1
8.1
8.1

NOTES:
Cooling Standard: 80 F db, 67 F wb indoor entering-air
temperature and 95 F db air entering outdoor unit.
Heating Standard: 70 F db, 60 F wb indoor entering-air
temperature and 47 F db air entering outdoor unit.

EER

9.0
9.0
9.0
9.2
9.2
9.2

kW
2.0
2.0
2.0
2.6
2.6
2.6

Optional Deflector Accessory


38H 48-70
38HK/HQ

Part No. 38HK580622

The air deflector accessory converts the


direction of air flow in the side discharge outdoor
condensing units from horizontal direction to vertical
direction to make the unit more flexible and suitable
for top discharge applications.
The air deflector accessory consists of three pieces of
painted galvanized sheet metal parts assembled at
site.

Note:
This accessory is used only with 38HK048-070

38HK/HQ

Base Unit Dimensions


38H 018-036

UNIT 38H
048-070

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

3-1316

944.6

3-8916

1131.9

1-5116

433.4

1-6716

468.3

2-612

774.7

1-758

498.5

1-758

498.5

2-558

752.5

NOTES:
1. Required clearances: with coil facing wall
allow 8 in. minimum clearance on coil side and
coil end, and 3 ft minimum clearance on
compressor end and fan side.
2. Dimensions in [ ] are in millimeters.

38HK/HQ

Base Unit Dimensions


38H 048-070

Electrical Data
COOL ONLY MODELS

70

OUTDOOR
MODEL
38HKC018US70
38HKR018US70
38HKC018DS70
38HKC018US70
38HKR018US70
38HKC024US70
38HKR024US70
38HKC024DS70
38HKC030US70
38HKC030DS70
38HKC36US70
38HKC36DS70
38HKC48US90
38HKC48DS90
38HKC60DS90
38HKC60US90
38HKS70DS90

Nominal
Cap. MBtuh

OUTDOOR
MODEL

Power Supply

18
24

38HQR018US70
38HQR024US70

220-240/1/50
220-240/1/50

38HK/HQ

Nominal
Cap. MBtuh

18

24
30
36
48
60

Power Supply
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50

Compressor
FLA
LRA
9.7
51.0
9.7
51.0
9.7
51.0
9.7
51.0
9.7
51.0
14.0
58.0
14.0
58.0
14.0
58.0
13.4
85.0
13.4
85.0
13.4
85.0
17.0
90.0
6.7
53.0
6.7
53.0
9.1
82.0
9.1
82.0
9.6
82.0

Fan
FLA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.3
2.3
2.3
2.3
2.3

Compressor
FLA
LRA
9.7
51.0
14.0
58.0

Fan
FLA
1.0
1.0

HEAT PUMP MODELS

LEGEND
FLA Full Load Amps
LRA Locked Rotor Amps
RLA Rated Load Amps
MCA Minimum Circuit Amps
MOCP Maximum Over current Protection Amps

Controls
Unit operation
NOTE: AUTO fan mode is used as the unit
operation example for ALL fan coil units in
this section. Contact your local Carrier dealer
for operation information in other fan modes.
Fan coil units Duct free fan coil units have
a self-contained control system that determines
the set point for fan coil operation, fan mode
operation, and heating mode operation (if
provided). The un-ducted fan coil and ducted
fan coil units are equipped with a thermostat.
For ducted fan coils the field installed
thermostat determines the set point for fan
mode operation, and electric heat operation (if
provided).
On a call for cooling operation by a single fan
coil unit, a signal is sent to the 38H outdoor
unit and energizes a control relay.

The indoor blower starts according to the


normal fan coil unit sequence of operation.
The control relay (in the outdoor unit) initiates
operation of a cooling cycle for the
compressor. As the set point at the fan coil is
satisfied, its individual signal to the 38HK unit
stops.
38 Series outdoor condensing unit The
outdoor unit is equipped with a control that
monitors the indoor fan coil cooling request.
Unit malfunction Each unit is equipped
with a high-pressure switch (HPS), a low
pressure switch (LPS),
Compressor over current protection is
achieved by an internal line break overload,
which automatically resets when the motor
temperature cools to a satisfactory level.

Detailed Performance Data

Nom
Cap.
Mbtuh

Evaporator
Air
CFM

450

18

550

650

450

24

550

650

600

30

700

800

800

36

950

1100

EWB

72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

75
Cap. MBtuh
Tot
22.6
20.9
18.9
18.0
22.9
21.3
19.3
18.8
23.1
21.5
19.7
19.5
29.0
26.8
24.2
23.0
29.3
27.3
24.8
24.1
29.6
27.6
25.3
25.0
34.3
31.7
28.7
27.3
34.7
32.3
29.4
28.6
35.1
32.7
30.0
29.6
40.7
37.6
34.0
32.4
41.2
38.3
34.9
33.9
41.6
38.8
35.6
35.1

Sen
11.2
13.9
16.4
17.3
11.6
14.7
17.5
18.1
11.9
15.4
18.5
18.7
14.4
17.9
21.1
22.2
14.9
18.9
22.5
23.2
15.3
19.8
23.7
24.0
16.0
19.9
23.4
24.7
16.6
21.0
25.0
25.8
17.0
22.0
26.4
26.7
20.4
25.4
29.9
31.4
21.1
26.8
31.9
32.9
21.7
28.0
33.6
34.1

CONDENSER AIR ENTERING Deg. F


95
105

85
Tot
Sys
Kw
2.07
2.02
1.97
1.94
2.12
2.07
2.02
2.00
2.17
2.12
2.07
2.05
2.67
2.60
2.53
2.50
2.73
2.67
2.60
2.57
2.80
2.73
2.66
2.64
2.71
2.65
2.57
2.54
2.78
2.71
2.64
2.61
2.84
2.78
2.70
2.69
3.43
3.35
3.25
3.21
3.51
3.43
3.34
3.30
3.60
3.51
3.42
3.40

Cap. MBtuh
Tot
21.8
19.9
17.8
17.2
22.1
20.3
18.3
17.9
22.3
20.6
18.7
18.6
27.9
25.5
22.8
22.0
28.3
26.0
23.4
23.0
28.6
26.4
24.0
23.9
33.1
30.2
27.0
26.1
33.5
30.8
27.7
27.2
33.9
31.2
28.4
28.3
39.2
35.8
32.0
30.9
39.8
36.5
32.9
32.3
40.2
37.1
33.7
33.6

Sen
11.0
13.6
15.9
16.5
11.4
14.4
17.0
17.2
11.8
15.2
18.0
17.9
14.1
17.4
20.4
21.2
14.6
18.5
21.8
22.2
15.1
19.5
23.1
23.0
15.7
19.4
22.7
23.5
16.3
20.6
24.3
24.6
16.8
21.7
25.7
25.6
20.0
24.7
28.9
30.0
20.8
26.2
30.9
31.4
21.4
27.6
32.7
32.6

Tot
Sys
Kw
2.23
2.17
2.09
2.07
2.28
2.22
2.16
2.14
2.33
2.26
2.21
2.21
2.87
2.79
2.69
2.66
2.93
2.86
2.77
2.76
2.99
2.91
2.84
2.84
2.92
2.84
2.74
2.70
2.98
2.90
2.82
2.80
3.04
2.96
2.89
2.89
3.69
3.59
3.46
3.42
3.76
3.67
3.57
3.54
3.85
3.74
3.65
3.65

Cap. MBtuh
Tot
20.7
18.7
16.7
16.3
21.1
19.1
17.1
17.0
21.3
19.4
17.7
17.7
26.6
24.0
21.4
20.9
27.0
24.5
21.9
21.9
27.3
24.9
22.6
22.7
31.5
28.4
25.3
24.7
32.0
29.0
26.0
25.9
32.4
29.5
26.8
26.8
37.4
33.7
30.0
29.3
38.0
34.4
30.8
30.7
38.4
35.0
31.8
31.8

Sen
10.6
13.1
15.3
15.6
11.1
14.0
16.4
16.4
11.5
14.8
17.0
17.0
13.7
16.9
19.7
20.1
14.3
18.0
21.1
21.1
14.8
19.1
21.8
21.8
15.2
18.7
21.9
22.4
15.8
20.0
23.5
23.4
16.5
21.2
24.2
24.2
19.4
23.9
27.9
28.5
20.2
25.5
29.9
29.8
21.0
27.0
30.9
30.9

Tot
Sys
Kw
2.38
2.31
2.21
2.19
2.43
2.37
2.28
2.28
2.48
2.42
2.36
2.36
3.07
2.98
2.85
2.81
3.13
3.05
2.93
2.93
3.20
3.11
3.03
3.03
3.12
3.03
2.89
2.86
3.18
3.10
2.98
2.98
3.25
3.17
3.08
3.08
3.94
3.83
3.66
3.62
4.02
3.92
3.76
3.76
4.11
4.00
3.90
3.90

Cap.
MBtuh
Tot
19.6
17.4
15.5
15.4
19.9
17.8
16.1
16.1
20.2
18.1
16.7
16.7
25.1
22.4
19.9
19.8
25.6
22.8
20.6
20.6
25.9
23.2
21.4
21.4
29.7
26.5
23.6
23.4
30.3
27.0
24.4
24.4
30.7
27.4
25.3
25.3
35.3
31.4
28.0
27.8
35.9
32.1
29.0
29.0
36.4
32.6
30.0
30.0

Sen
10.2
12.6
14.7
14.8
10.8
13.5
15.4
15.5
11.2
14.3
16.0
16.0
13.2
16.2
18.9
19.0
13.8
17.4
19.9
19.9
14.4
18.4
20.6
20.6
14.6
18.0
21.0
21.1
15.4
19.3
22.1
22.1
16.0
20.5
22.9
22.9
18.6
23.0
26.8
27.0
19.6
24.6
28.1
28.2
20.5
26.1
29.2
29.2

Tot
Sys
Kw
2.55
2.46
2.33
2.33
2.60
2.53
2.41
2.41
2.65
2.57
2.49
2.49
3.28
3.16
3.00
2.99
3.35
3.25
3.10
3.10
3.42
3.31
3.20
3.20
3.33
3.22
3.05
3.04
3.41
3.31
3.15
3.15
3.47
3.36
3.26
3.26
4.21
4.07
3.86
3.85
4.31
4.18
3.98
3.98
4.39
4.25
4.12
4.12

115
Cap.
MBtuh
Tot
18.3
16.1
14.4
14.4
18.6
16.4
15.1
15.1
18.8
16.7
15.7
15.7
23.4
20.7
18.5
18.5
23.8
21.1
19.4
19.4
24.1
21.4
20.1
20.1
27.8
24.5
21.9
21.9
28.2
25.0
22.9
22.9
28.6
25.3
23.8
23.8
33.0
29.1
26.0
26.0
33.5
29.6
27.2
27.2
33.9
30.0
28.2
28.2

Sen
9.8
12.1
13.9
13.9
10.3
13.0
14.5
14.5
10.8
13.8
15.0
15.0
12.6
15.6
17.8
17.8
13.3
16.7
18.6
18.7
13.9
17.7
19.3
19.3
14.0
17.3
19.8
19.8
14.7
18.5
20.7
20.7
15.4
19.7
21.5
21.5
17.8
22.1
25.3
25.3
18.8
23.6
26.4
26.4
19.7
25.1
27.4
27.4

Tot
Sys
Kw
2.72
2.58
2.46
2.46
2.77
2.65
2.55
2.55
2.82
2.71
2.63
2.63
3.50
3.33
3.17
3.17
3.56
3.41
3.28
3.28
3.63
3.49
3.39
3.39
3.55
3.38
3.22
3.22
3.62
3.46
3.33
3.33
3.69
3.55
3.45
3.45
4.49
4.27
4.08
4.08
4.58
4.38
4.21
4.21
4.67
4.48
4.36
4.36

120
Cap.
MBtuh
Tot
17.4
15.3
13.7
13.7
17.7
15.6
14.3
14.3
17.9
15.8
14.9
14.9
22.3
19.7
17.6
17.6
22.6
20.0
18.4
18.4
22.9
20.3
19.1
19.1
26.4
23.3
20.8
20.8
26.8
23.7
21.8
21.8
27.2
24.1
22.6
22.6
31.3
27.6
24.7
24.7
31.8
28.1
25.8
25.9
32.2
28.5
26.8
26.8

Sen
9.3
11.5
13.2
13.2
9.8
12.3
13.8
13.8
10.3
13.1
14.3
14.3
12.0
14.8
16.9
16.9
12.6
15.8
17.7
17.7
13.2
16.8
18.4
18.4
13.3
16.4
18.8
18.8
14.0
17.6
19.7
19.7
14.7
18.7
20.4
20.4
16.9
21.0
24.0
24.0
17.8
22.4
25.1
25.1
18.7
23.8
26.0
26.0

Tot
Sys
Kw
2.82
2.66
2.54
2.55
2.87
2.72
2.63
2.63
2.93
2.79
2.72
2.72
3.63
3.42
3.27
3.28
3.69
3.50
3.38
3.38
3.77
3.60
3.50
3.50
3.69
3.48
3.33
3.33
3.75
3.56
3.44
3.44
3.83
3.65
3.56
3.56
4.66
4.40
4.21
4.21
4.74
4.50
4.35
4.35
4.84
4.62
4.50
4.50

38HK/HQ

Matching 38HK with 42TX

Detailed Performance Data cont.


38HK/HQ

Matching 38HK with 42TX

Evaporator
Air
Nom Cap.
Mbtuh

CFM EWB

1100

48

1250

1400

1300

60

1450

1600

72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

75
Cap. MBtuh
Tot
52.3
48.4
43.8
41.6
53.0
49.3
44.8
43.6
53.5
49.9
45.7
45.1
68.5
63.4
57.3
54.5
69.4
64.6
58.7
57.1
70.1
65.4
59.9
59.1

Sen
25.6
31.8
37.5
39.4
26.5
33.6
40.0
41.3
27.3
35.2
42.2
42.7
34.9
43.3
51.0
53.6
36.0
45.7
54.4
56.2
37.1
47.8
57.4
58.1

CONDENSER AIR ENTERING Deg. F


95
105

85
Tot
Sys
Kw
3.86
3.76
3.66
3.61
3.95
3.86
3.75
3.72
4.05
3.95
3.85
3.82
5.15
5.03
4.89
4.82
5.28
5.15
5.01
4.97
5.40
5.28
5.14
5.11

Cap. MBtuh
Tot
50.5
46.0
41.2
39.8
51.2
47.0
42.3
41.6
51.6
47.6
43.3
43.2
66.1
60.3
54.0
52.1
67.0
61.5
55.4
54.4
67.7
62.4
56.8
56.6

Sen
25.1
31.0
36.3
37.7
26.0
32.9
38.8
39.4
26.9
34.6
41.1
40.9
34.1
42.2
49.4
51.2
35.4
44.7
52.8
53.5
36.6
47.1
55.8
55.6

Tot
Sys
Kw
4.15
4.03
3.89
3.85
4.23
4.13
4.01
3.99
4.33
4.21
4.11
4.11
5.55
5.39
5.20
5.14
5.66
5.51
5.36
5.33
5.78
5.62
5.48
5.48

Cap. MBtuh
Tot
48.0
43.3
38.6
37.7
48.8
44.3
39.6
39.5
49.4
45.0
40.9
40.9
62.9
56.7
50.6
49.4
64.0
58.0
51.9
51.8
64.7
59.0
53.6
53.6

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

10

Sen
24.3
30.0
35.1
35.8
25.4
32.0
37.6
37.4
26.3
33.9
38.8
38.8
33.0
40.8
47.7
48.6
34.5
43.5
51.1
50.9
35.8
46.0
52.7
52.7

Tot
Sys
Kw
4.43
4.30
4.12
4.07
4.53
4.41
4.23
4.23
4.62
4.50
4.39
4.39
5.92
5.75
5.50
5.44
6.05
5.89
5.66
5.66
6.17
6.02
5.86
5.86

Cap. MBtuh
Tot
45.4
40.4
36.0
35.7
46.2
41.3
37.3
37.3
46.8
41.9
38.6
38.6
59.4
53.0
47.2
46.8
60.5
54.1
48.8
48.8
61.3
54.8
50.6
50.6

Sen
23.4
28.8
33.7
33.8
24.6
30.9
35.3
35.3
25.7
32.8
36.6
36.6
31.8
39.2
45.8
46.0
33.4
42.0
48.0
48.0
34.9
44.6
49.8
49.8

115
Tot
Sys
Kw

4.74
4.57
4.34
4.33
4.84
4.70
4.48
4.48
4.94
4.79
4.63
4.63
6.33
6.11
5.80
5.78
6.47
6.28
5.98
5.98
6.59
6.39
6.19
6.19

Cap.
MBtuh
Tot
42.4
37.4
33.4
33.5
43.1
38.1
35.0
35.0
43.6
38.6
36.3
36.3
55.5
49.0
43.8
43.8
56.4
49.9
45.8
45.9
57.1
50.6
47.5
47.5

Sen
22.4
27.7
31.7
31.7
23.6
29.7
33.2
33.2
24.7
31.5
34.4
34.4
30.4
37.6
43.1
43.1
32.0
40.3
45.1
45.1
33.6
42.8
46.7
46.8

120
Tot
Sys
Kw
5.06
4.81
4.59
4.59
5.15
4.93
4.74
4.74
5.25
5.04
4.90
4.90
6.75
6.42
6.12
6.12
6.88
6.58
6.33
6.33
7.02
6.74
6.55
6.55

Cap.
MBtuh
Tot
40.3
35.5
31.8
31.8
40.9
36.2
33.2
33.2
41.4
36.7
34.5
34.5
52.7
46.6
41.6
41.6
53.6
47.4
43.5
43.6
54.3
48.1
45.2
45.2

Sen
21.2
26.3
30.1
30.1
22.4
28.2
31.5
31.5
23.5
29.9
32.7
32.7
28.9
35.8
40.9
40.9
30.4
38.3
42.8
42.8
31.9
40.7
44.4
44.4

Tot
Sys
Kw
5.25
4.95
4.73
4.74
5.33
5.06
4.89
4.89
5.44
5.20
5.06
5.06
7.01
6.61
6.32
6.33
7.12
6.76
6.54
6.54
7.27
6.94
6.76
6.76

Detailed Performance Data

CONDENSER AIR ENTERING Deg. F

Evaporator Air
Nom Cap.
MBtuh

CFM

525

18

600

675

550

24

625

700

1000

30

1150

1300

1050

36

1200

1350

EWB
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

38HK/HQ

Matching 38HK with FB4A

75
Cap. MBtuh
Tot
23.6
21.9
19.8
18.8
23.9
22.3
20.3
19.7
24.2
22.6
20.7
20.4
28.7
26.6
24.0
22.8
29.1
27.1
24.6
23.9
29.4
27.4
25.1
24.8
35.6
32.9
29.8
28.3
36.0
33.5
30.5
29.6
36.4
33.9
31.1
30.7
40.8
37.7
34.1
32.4
41.3
38.4
34.9
34.0
41.7
38.9
35.6
35.2

Sen
11.2
13.9
16.4
17.3
11.6
14.7
17.5
18.1
11.9
15.4
18.5
18.7
13.3
16.5
19.5
20.5
13.8
17.4
20.8
21.4
14.1
18.3
21.9
22.2
18.4
22.9
27.0
28.4
19.1
24.1
28.8
29.7
19.6
25.3
30.3
30.7
20.8
25.9
30.5
32.1
21.5
27.3
32.5
33.6
22.1
28.6
34.3
34.7

85
Tot
Cap. MBtuh
Sys
Kw
Tot Sen
2.19 22.8 11.0
2.13 20.8 13.6
2.07 18.6 15.9
2.05 18.0 16.5
2.24 23.1 11.4
2.19 21.2 14.4
2.13 19.1 17.0
2.11 18.8 17.2
2.29 23.3 11.8
2.24 21.5 15.2
2.18 19.6 18.0
2.17 19.5 17.9
2.67 27.7 13.0
2.60 25.3 16.1
2.53 22.6 18.8
2.50 21.8 19.5
2.73 28.1 13.5
2.67 25.8 17.1
2.60 23.2 20.1
2.57 22.8 20.4
2.80 28.3 14.0
2.73 26.2 18.0
2.66 23.8 21.3
2.64 23.7 21.2
2.89 34.3 18.0
2.82 31.3 22.3
2.74 28.0 26.1
2.70 27.0 27.1
2.96 34.8 18.7
2.89 31.9 23.6
2.81 28.8 27.9
2.78 28.3 28.3
3.03 35.1 19.3
2.96 32.4 24.9
2.88 29.5 29.5
2.86 29.4 29.4
3.50 39.3 20.4
3.41 35.9 25.2
3.32 32.1 29.5
3.28 31.0 30.6
3.59 39.9 21.2
3.50 36.6 26.7
3.40 33.0 31.5
3.37 32.4 32.0
3.67 40.2 21.9
3.59 37.1 28.1
3.49 33.8 33.4
3.47 33.6 33.2

95
Tot
Sys
Kw
2.35
2.29
2.21
2.18
2.40
2.34
2.27
2.26
2.45
2.39
2.33
2.33
2.87
2.79
2.69
2.66
2.93
2.86
2.77
2.76
2.99
2.91
2.84
2.84
3.11
3.02
2.91
2.88
3.17
3.09
3.00
2.98
3.24
3.15
3.07
3.07
3.77
3.66
3.53
3.49
3.84
3.74
3.64
3.62
3.93
3.82
3.72
3.72

Cap. MBtuh
Tot
21.7
19.6
17.4
17.0
22.1
20.0
17.9
17.8
22.3
20.3
18.5
18.5
26.4
23.8
21.2
20.7
26.8
24.3
21.8
21.7
27.1
24.7
22.5
22.5
32.7
29.4
26.3
25.7
33.2
30.1
27.0
26.9
33.6
30.6
27.8
27.8
37.4
33.7
30.1
29.4
38.1
34.5
30.9
30.8
38.5
35.1
31.9
31.9

Sen
10.6
13.1
15.3
15.6
11.1
14.0
16.4
16.4
11.5
14.8
17.0
17.0
12.6
15.6
18.2
18.6
13.2
16.6
19.5
19.4
13.7
17.6
20.1
20.1
17.5
21.6
25.2
25.7
18.2
23.0
27.0
26.9
18.9
24.3
27.9
27.9
19.7
24.4
28.5
29.1
20.6
26.0
30.5
30.4
21.4
27.5
31.5
31.5

105
Tot
Sys
Kw
2.51
2.44
2.33
2.31
2.99
2.50
2.40
2.40
2.62
2.55
2.49
2.49
3.07
2.98
2.85
2.81
3.13
3.05
2.93
2.93
3.20
3.11
3.03
3.03
3.32
3.22
3.08
3.05
3.39
3.30
3.17
3.17
3.46
3.37
3.28
3.28
4.02
3.90
3.73
3.69
4.11
4.00
3.84
3.84
4.19
4.09
3.98
3.98

Tot
Cap. MBtuh
Sys
Tot Sen Kw
20.5 10.2 2.69
18.3 12.6 2.59
16.3 14.7 2.46
16.1 14.8 2.45
20.9 10.8 2.75
18.6 13.5 2.67
16.8 15.4 2.54
16.8 15.4 2.54
21.1 11.2 2.80
18.9 14.3 2.71
17.4 16.0 2.63
17.4 16.0 2.63
24.9 12.1 3.28
22.2 15.0 3.16
19.8 17.5 3.00
19.6 17.6 2.99
25.4 12.7 3.35
22.6 16.0 3.25
20.5 18.3 3.10
20.4 18.3 3.10
25.7 13.3 3.42
23.0 17.0 3.31
21.2 19.0 3.20
21.2 19.0 3.20
30.8 16.8 3.55
27.5 20.7 3.42
24.5 24.2 3.25
24.3 24.3 3.24
31.4 17.7 3.62
28.1 22.2 3.52
25.3 25.4 3.35
25.3 25.4 3.35
31.8 18.4 3.69
28.5 23.6 3.58
26.3 26.3 3.47
26.2 26.3 3.47
35.3 19.0 4.30
31.5 23.4 4.15
28.1 27.4 3.94
27.8 27.5 3.93
36.0 20.0 4.39
32.2 25.1 4.27
29.0 28.7 4.06
29.0 28.7 4.06
36.4 20.9 4.48
32.6 26.6 4.34
30.1 29.7 4.20
30.1 29.7 4.20

115
Cap.
MBtuh
Tot
19.1
16.9
15.1
15.1
19.5
17.2
15.8
15.8
19.7
17.4
16.4
16.4
23.3
20.5
18.4
18.4
23.6
20.9
19.2
19.2
23.9
21.2
19.9
19.9
28.8
25.4
22.7
22.7
29.3
25.9
23.8
23.8
29.6
26.3
24.7
24.7
33.0
29.2
26.1
26.1
33.6
29.7
27.3
27.3
34.0
30.1
28.3
28.3

Sen
9.8
12.1
13.9
13.9
10.3
13.0
14.5
14.5
10.8
13.8
15.0
15.0
11.6
14.4
16.4
16.4
12.2
15.4
17.2
17.2
12.8
16.3
17.8
17.8
16.1
19.9
22.8
22.8
16.9
21.3
23.8
23.8
17.8
22.6
24.7
24.7
18.2
22.5
25.7
25.8
19.2
24.1
26.9
26.9
20.1
25.6
27.9
27.9

120
Tot
Sys
Kw
2.87
2.73
2.60
2.60
2.92
2.79
2.69
2.69
2.98
2.86
2.78
2.78
3.50
3.33
3.17
3.17
3.56
3.41
3.28
3.28
3.63
3.49
3.39
3.39
3.78
3.60
3.43
3.43
3.85
3.69
3.55
3.55
3.93
3.77
3.67
3.67
4.59
4.36
4.16
4.16
4.67
4.47
4.30
4.30
4.77
4.57
4.45
4.45

Cap. MBtuh
Tot
18.1
15.9
14.4
14.4
18.4
16.2
15.1
15.1
18.7
16.4
15.6
15.6
22.0
19.3
17.5
17.5
22.4
19.7
18.3
18.3
22.7
20.0
19.0
19.0
27.3
24.0
21.7
21.7
27.8
24.4
22.7
22.7
28.1
24.7
23.5
23.5
31.3
27.5
24.9
24.9
31.8
28.0
26.0
26.0
32.2
28.4
26.9
26.9

Sen
9.4
11.7
13.2
13.2
10.0
12.6
13.8
13.8
10.5
13.4
14.3
14.3
11.2
13.9
15.7
15.7
11.8
14.9
16.4
16.4
12.4
15.9
17.0
17.0
15.5
19.3
21.7
21.7
16.4
20.7
22.7
22.7
17.2
22.0
23.5
23.5
17.5
21.8
24.6
24.6
18.5
23.4
25.7
25.7
19.5
24.9
26.6
26.6

Tot
Sys
Kw
2.97
2.81
2.68
2.69
3.02
2.87
2.77
2.77
3.09
2.95
2.87
2.87
3.63
3.42
3.27
3.28
3.69
3.50
3.38
3.38
3.77
3.60
3.50
3.50
3.92
3.70
3.54
3.55
3.99
3.79
3.66
3.66
4.07
3.89
3.79
3.79
4.76
4.49
4.29
4.30
4.84
4.59
4.44
4.44
4.94
4.71
4.59
4.59

11

Detailed Performance Data cont.


38HK/HQ

Matching 38HK with FB4A

Nom
Cap.
Mbtuh

CFM

1300

48

1500

1700

1450

60

1650

1850

1600

70

CONDENSER AIR ENTERING Deg. F

Evaporator Air

1800

2000

EWB
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

75
Cap. MBtuh
Tot
54.4
50.3
45.5
43.3
55.1
51.2
46.6
45.3
55.6
51.9
47.5
46.9
69.7
64.5
58.3
55.5
70.6
65.7
59.8
58.1
71.3
66.5
60.9
60.1
76.3
70.6
63.9
60.7
77.3
71.9
65.4
63.6
78.0
72.8
66.7
65.8

Sen
26.5
32.9
38.8
40.8
27.4
34.7
41.4
42.7
28.2
36.4
43.7
44.2
34.1
42.3
49.8
52.4
35.2
44.6
53.2
54.9
36.2
46.7
56.1
56.8
35.4
44.0
51.8
54.5
36.6
46.4
55.3
57.1
37.7
48.6
58.3
59.0

95

85
Tot
Cap. MBtuh
Sys
Kw
Tot Sen
4.03 52.4 25.9
3.93 47.8 32.1
3.82 42.8 37.6
3.77 41.3 39.0
4.12 53.2 26.9
4.03 48.8 34.0
3.91 44.0 40.1
3.88 43.2 40.7
4.22 53.7 27.8
4.12 49.5 35.8
4.01 45.0 42.5
3.99 44.9 42.3
5.16 67.3 33.3
5.04 61.4 41.2
4.90 54.9 48.2
4.83 53.0 50.0
5.29 68.2 34.6
5.16 62.6 43.7
5.02 56.4 51.6
4.97 55.4 52.3
5.41 68.8 35.7
5.29 63.5 46.0
5.15 57.7 54.5
5.12 57.5 54.3
5.3
73.6 34.6
5.1
67.2 42.8
5.0
60.1 50.1
4.9
58.0 52.0
5.4
74.7 36.0
5.3
68.5 45.4
5.1
61.7 53.6
5.1
60.6 54.4
5.5
75.4 37.2
5.4
69.5 47.9
5.2
63.2 56.7
5.2
63.0 56.5

Tot
Sys
Kw
4.33
4.21
4.06
4.01
4.42
4.31
4.18
4.16
4.51
4.39
4.28
4.28
5.55
5.40
5.21
5.15
5.66
5.52
5.37
5.34
5.79
5.63
5.49
5.49
5.6
5.5
5.3
5.2
5.8
5.6
5.5
5.4
5.9
5.7
5.6
5.6

Multipliers to Determine the Performance With Other Indoor Coils


Condenser
Evaporator
Cooling Cap.
Power
N. Cap. MBtuh
N. Cap. MBtuh
18
24
1.10
1.07
24
30
1.05
1.05
30
36
1.03
1.05
36
42
1.04
1.05
48
60
1.05
1.05
60
70
1.02
1.03

12

Cap. MBtuh
Tot
49.9
45.0
40.1
39.2
50.7
46.0
41.2
41.0
51.3
46.8
42.5
42.5
64.0
57.7
51.5
50.3
65.1
59.0
52.8
52.6
65.8
60.0
54.5
54.5
70.1
63.2
56.4
55.1
71.3
64.6
57.9
57.6
72.0
65.7
59.7
59.7

Sen
25.1
31.0
36.3
37.0
26.2
33.1
38.9
38.7
27.2
35.0
40.1
40.1
32.3
39.8
46.6
47.5
33.7
42.5
49.9
49.7
35.0
45.0
51.5
51.5
33.6
41.4
48.4
49.4
35.0
44.2
51.9
51.7
36.4
46.8
53.6
53.6

105
Tot
Sys
Kw
4.62
4.49
4.29
4.25
4.72
4.60
4.42
4.42
4.82
4.70
4.58
4.58
5.93
5.76
5.51
5.44
6.06
5.90
5.66
5.66
6.18
6.03
5.87
5.87
6.0
5.9
5.6
5.5
6.2
6.0
5.8
5.8
6.3
6.1
6.0
6.0

Tot
Cap. MBtuh
Sys
Tot Sen Kw
47.1 24.2 4.94
42.0 29.8 4.77
37.4 34.8 4.53
37.1 35.0 4.51
48.0 25.4 5.05
42.9 31.9 4.91
38.7 36.5 4.67
38.7 36.5 4.67
48.6 26.6 5.15
43.5 33.9 4.99
40.1 37.9 4.83
40.1 37.9 4.83
60.4 31.1 6.34
53.9 38.3 6.12
48.0 44.7 5.81
47.6 44.9 5.79
61.6 32.6 6.48
55.0 41.0 6.29
49.7 46.9 5.99
49.6 46.9 5.99
62.3 34.1 6.61
55.8 43.5 6.40
51.5 48.6 6.20
51.4 48.6 6.20
66.2 32.3 6.4
59.0 39.8 6.2
52.6 46.5 5.9
52.1 46.7 5.9
67.4 33.9 6.6
60.2 42.6 6.4
54.4 48.8 6.1
54.4 48.8 6.1
68.3 35.5 6.7
61.1 45.3 6.5
56.4 50.6 6.3
56.3 50.5 6.3

115
Cap.
MBtuh
Tot
44.0
38.9
34.7
34.8
44.8
39.6
36.4
36.3
45.3
40.1
37.7
37.7
56.5
49.9
44.6
44.6
57.4
50.8
46.6
46.6
58.1
51.5
48.4
48.4
61.8
54.6
48.8
48.8
62.9
55.6
51.0
51.0
63.6
56.4
52.9
52.9

Sen
23.1
28.6
32.8
32.8
24.4
30.7
34.3
34.3
25.6
32.6
35.6
35.6
29.7
36.8
42.1
42.1
31.3
39.4
44.0
44.0
32.8
41.8
45.7
45.6
30.9
38.3
43.8
43.8
32.6
41.0
45.8
45.8
34.1
43.5
47.5
47.5

120
Tot
Sys
Kw
5.27
5.02
4.78
4.78
5.37
5.14
4.94
4.94
5.48
5.26
5.11
5.11
6.76
6.43
6.14
6.14
6.89
6.59
6.34
6.34
7.03
6.75
6.56
6.56
6.9
6.5
6.2
6.2
7.0
6.7
6.4
6.4
7.1
6.9
6.7
6.7

Cap. MBtuh
Tot Sen
41.7 22.3
36.6 27.8
33.2 31.3
33.2 31.3
42.4 23.6
37.3 29.8
34.7 32.7
34.7 32.7
43.0 24.8
37.8 31.7
35.9 33.9
35.9 33.9
53.5 28.6
47.0 35.7
42.5 40.2
42.5 40.2
54.4 30.3
47.8 38.3
44.5 42.0
44.5 42.0
55.1 31.9
48.5 40.7
46.1 43.5
46.1 43.5
58.6 29.8
51.4 37.1
46.6 41.8
46.6 41.8
59.6 31.5
52.4 39.8
48.7 43.7
48.7 43.7
60.3 33.1
53.1 42.3
50.4 45.2
50.4 45.2

Notes:
1. Net Capacities shown include a deduction for evaporator fan
motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

Tot
Sys
Kw
5.47
5.16
4.94
4.95
5.56
5.28
5.10
5.10
5.68
5.42
5.28
5.28
7.02
6.62
6.33
6.34
7.13
6.77
6.55
6.55
7.28
6.95
6.78
6.78
7.1
6.7
6.4
6.5
7.3
6.9
6.7
6.7
7.4
7.1
6.9
6.9

Detailed Performance Data

Evaporator
Air
Nom Cap.
Mbtuh

CFM

300

18

375

425

325

24

400

450

570

36 Evap &
30 Cond

650

750

570

36

650

750

680

48 Evap
&
36
Cond

830

975

75

Cap. MBtuh Tot


EWB
Sys
Tot Sen Kw
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

20.6
19.1
17.2
16.4
20.9
19.4
17.7
17.2
21.1
19.7
18.0
17.8
25.2
23.3
21.1
20.0
25.5
23.7
21.6
21.0
25.7
24.0
22.0
21.7
33.2
30.7
27.8
26.4
33.6
31.3
28.5
27.7
33.9
31.7
29.0
28.6
36.0
33.3
30.1
28.6
36.4
33.9
30.8
30.0
36.8
34.3
31.4
31.0
38.7
35.8
32.4
30.8
39.2
36.5
33.2
32.2
39.6
36.9
33.8
33.4

11.2
13.9
16.4
17.3
11.6
14.7
17.5
18.1
11.9
15.4
18.5
18.7
12.3
15.2
17.9
18.9
12.7
16.1
19.1
19.8
13.0
16.8
20.2
20.4
15.2
18.9
22.3
23.4
15.7
19.9
23.8
24.5
16.2
20.9
25.1
25.4
16.8
20.9
24.6
25.9
17.4
22.0
26.3
27.1
17.9
23.1
27.7
28.1
18.4
22.9
27.0
28.4
19.1
24.1
28.8
29.7
19.6
25.3
30.3
30.7

CONDENSER AIR ENTERING Deg. F


95
105

85

2.02
1.97
1.92
1.89
2.07
2.02
1.97
1.95
2.12
2.07
2.02
2.00
2.48
2.42
2.35
2.32
2.54
2.48
2.41
2.39
2.60
2.54
2.47
2.45
2.78
2.71
2.64
2.60
2.85
2.78
2.71
2.68
2.92
2.85
2.77
2.76
3.0
2.9
2.8
2.8
3.0
3.0
2.9
2.8
3.1
3.0
2.9
2.9
3.13
3.06
2.97
2.93
3.21
3.13
3.05
3.02
3.28
3.21
3.12
3.10

Cap. MBtuh Tot Sys Cap. MBtuh


Kw
Tot
Sen
Tot
Sen

Tot
Sys
Kw

Cap. MBtuh
Tot

19.9
18.1
16.2
15.7
20.2
18.5
16.7
16.4
20.4
18.8
17.1
17.0
24.3
22.2
19.8
19.1
24.6
22.6
20.4
20.0
24.8
22.9
20.8
20.8
32.0
29.2
26.1
25.2
32.5
29.8
26.9
26.4
32.8
30.2
27.5
27.4
34.7
31.6
28.3
27.3
35.2
32.3
29.1
28.6
35.5
32.7
29.8
29.7
37.3
34.1
30.5
29.4
37.9
34.7
31.3
30.7
38.2
35.2
32.1
31.9

2.32
2.25
2.16
2.13
2.99
2.31
2.22
2.22
2.42
2.36
2.30
2.30
2.85
2.76
2.64
2.61
2.91
2.83
2.72
2.72
2.97
2.89
2.81
2.81
3.20
3.10
2.97
2.93
3.26
3.18
3.05
3.05
3.33
3.25
3.16
3.16
3.4
3.3
3.2
3.1
3.5
3.4
3.2
3.2
3.5
3.5
3.4
3.4
3.60
3.49
3.34
3.30
3.68
3.58
3.44
3.44
3.75
3.66
3.56
3.56

17.9
15.9
14.2
14.1
18.2
16.3
14.7
14.7
18.4
16.5
15.2
15.2
21.8
19.4
17.3
17.2
22.2
19.9
17.9
17.9
22.5
20.1
18.6
18.6
28.8
25.7
22.9
22.7
29.3
26.2
23.7
23.7
29.7
26.6
24.5
24.5
31.2
27.8
24.8
24.5
31.7
28.4
25.6
25.6
32.1
28.8
26.5
26.6
33.6
29.9
26.6
26.4
34.2
30.5
27.6
27.6
34.6
31.0
28.6
28.6

11.0
13.6
15.9
16.5
11.4
14.4
17.0
17.2
11.8
15.2
18.0
17.9
12.0
14.8
17.4
18.0
12.5
15.7
18.6
18.8
12.9
16.6
19.6
19.6
14.9
18.4
21.6
22.4
15.5
19.5
23.0
23.4
16.0
20.6
24.4
24.3
16.5
20.3
23.8
24.7
17.1
21.6
25.5
25.8
17.7
22.7
26.9
26.8
18.0
22.3
26.1
27.1
18.7
23.6
27.9
28.3
19.3
24.9
29.5
29.4

2.17
2.11
2.04
2.02
2.22
2.16
2.10
2.09
2.27
2.21
2.15
2.15
2.66
2.59
2.50
2.47
2.72
2.65
2.57
2.56
2.78
2.70
2.63
2.63
2.99
2.91
2.81
2.77
3.05
2.98
2.89
2.88
3.12
3.04
2.96
2.96
3.2
3.1
3.0
2.9
3.2
3.2
3.1
3.1
3.3
3.2
3.1
3.1
3.37
3.28
3.16
3.12
3.44
3.35
3.26
3.24
3.51
3.42
3.33
3.33

18.9
17.1
15.2
14.9
19.2
17.5
15.6
15.6
19.5
17.7
16.1
16.1
23.1
20.8
18.6
18.2
23.5
21.3
19.1
19.0
23.8
21.7
19.7
19.7
30.5
27.5
24.5
24.0
31.0
28.1
25.2
25.1
31.3
28.6
26.0
26.0
33.0
29.8
26.5
25.9
33.6
30.4
27.2
27.1
33.9
30.9
28.1
28.1
35.5
32.0
28.6
27.9
36.1
32.8
29.3
29.2
36.5
33.3
30.3
30.3

10.6
13.1
15.3
15.6
11.1
14.0
16.4
16.4
11.5
14.8
17.0
17.0
11.6
14.3
16.8
17.1
12.1
15.3
18.0
17.9
12.6
16.2
18.5
18.5
14.4
17.8
20.8
21.2
15.1
19.0
22.3
22.2
15.6
20.1
23.0
23.0
15.9
19.7
23.0
23.5
16.6
21.0
24.7
24.6
17.3
22.2
25.4
25.5
17.5
21.6
25.2
25.7
18.2
23.0
27.0
26.9
18.9
24.3
27.9
27.9

115

120

Sen

Tot Cap. MBtuh


Sys
Kw
Tot Sen

Tot
Sys
Kw

10.2
12.6
14.7
14.8
10.8
13.5
15.4
15.5
11.2
14.3
16.0
16.0
11.2
13.8
16.1
16.2
11.8
14.8
16.9
16.9
12.3
15.7
17.5
17.5
13.9
17.1
20.0
20.1
14.6
18.3
21.0
21.0
15.2
19.5
21.7
21.7
15.3
18.9
22.1
22.2
16.1
20.3
23.2
23.2
16.8
21.5
24.0
24.0
16.8
20.7
24.2
24.3
17.7
22.2
25.4
25.4
18.4
23.6
26.3
26.3

2.48
2.40
2.27
2.27
2.54
2.46
2.35
2.35
2.59
2.51
2.43
2.43
3.04
2.94
2.78
2.78
3.11
3.02
2.88
2.88
3.17
3.07
2.97
2.97
3.42
3.30
3.13
3.12
3.49
3.39
3.23
3.23
3.56
3.45
3.34
3.34
3.6
3.5
3.3
3.3
3.7
3.6
3.4
3.4
3.8
3.7
3.6
3.6
3.85
3.71
3.52
3.51
3.93
3.82
3.64
3.64
4.01
3.88
3.76
3.76

2.65
2.52
2.40
2.40
2.70
2.58
2.48
2.48
2.75
2.64
2.57
2.57
3.24
3.09
2.94
2.94
3.30
3.16
3.04
3.04
3.37
3.24
3.15
3.15
3.65
3.47
3.31
3.31
3.71
3.55
3.42
3.42
3.79
3.64
3.54
3.54
3.9
3.7
3.5
3.5
3.9
3.8
3.6
3.6
4.0
3.9
3.8
3.8
4.10
3.90
3.72
3.72
4.18
4.00
3.85
3.85
4.27
4.09
3.98
3.98

16.7
14.7
13.2
13.2
17.0
15.0
13.8
13.8
17.2
15.2
14.3
14.3
20.4
18.0
16.1
16.1
20.7
18.3
16.8
16.8
21.0
18.6
17.5
17.5
26.9
23.7
21.2
21.2
27.3
24.2
22.2
22.2
27.7
24.5
23.0
23.0
29.1
25.7
23.0
23.0
29.6
26.2
24.0
24.1
30.0
26.5
24.9
24.9
31.3
27.7
24.7
24.7
31.9
28.2
25.9
25.9
32.3
28.6
26.8
26.8

9.8
12.1
13.9
13.9
10.3
13.0
14.5
14.5
10.8
13.8
15.0
15.0
10.7
13.2
15.2
15.2
11.3
14.2
15.9
15.9
11.8
15.1
16.4
16.4
13.3
16.4
18.8
18.8
14.0
17.6
19.7
19.7
14.7
18.7
20.4
20.4
14.7
18.2
20.8
20.8
15.5
19.5
21.8
21.8
16.2
20.7
22.6
22.6
16.1
19.9
22.8
22.8
16.9
21.3
23.8
23.8
17.8
22.6
24.7
24.7

38HK/HQ

Matching 38HK with Ceiling Cassette

Tot

Sen

Tot
Sys
Kw

15.9
14.0
12.5
12.5
16.1
14.3
13.1
13.1
16.3
14.5
13.6
13.6
19.4
17.1
15.3
15.3
19.7
17.4
16.0
16.0
19.9
17.7
16.6
16.6
25.5
22.6
20.2
20.2
26.0
23.0
21.1
21.1
26.3
23.3
21.9
21.9
27.7
24.4
21.8
21.8
28.1
24.9
22.8
22.8
28.5
25.2
23.7
23.7
29.8
26.3
23.5
23.5
30.3
26.8
24.6
24.6
30.6
27.1
25.5
25.5

9.3
11.5
13.2
13.2
9.8
12.3
13.8
13.8
10.3
13.1
14.3
14.3
10.2
12.6
14.4
14.4
10.7
13.5
15.1
15.1
11.2
14.3
15.6
15.6
12.6
15.6
17.9
17.9
13.3
16.7
18.7
18.7
13.9
17.8
19.4
19.4
13.9
17.3
19.8
19.8
14.7
18.5
20.7
20.7
15.4
19.6
21.4
21.4
15.3
18.9
21.6
21.6
16.1
20.2
22.6
22.6
16.9
21.5
23.5
23.5

2.75
2.59
2.48
2.48
2.79
2.65
2.56
2.56
2.85
2.72
2.65
2.65
3.37
3.18
3.04
3.04
3.42
3.25
3.14
3.14
3.49
3.34
3.25
3.25
3.78
3.57
3.41
3.42
3.84
3.65
3.53
3.53
3.93
3.75
3.65
3.65
4.0
3.8
3.6
3.6
4.1
3.9
3.8
3.8
4.2
4.0
3.9
3.9
4.26
4.02
3.84
3.85
4.33
4.11
3.97
3.97
4.42
4.22
4.11
4.11

Cap. MBtuh

13

Detailed Performance Data cont.


38HK/HQ

Matching 38HK with Ceiling Cassette

Nom Cap.
Mbtuh

Evaporator
Air
CFM

680

48

830

975

EWB
72
67
62
57
72
67
62
57
72
67
62
57

75
Cap.
MBtuh
Tot Sen
47.3 20.8
43.7 25.9
39.5 30.5
37.6 32.1
47.9 21.5
44.5 27.3
40.5 32.5
39.4 33.6
48.3 22.1
45.1 28.6
41.3 34.3
40.8 34.7

85
Tot
Sys
Kw
3.63
3.54
3.44
3.40
3.72
3.63
3.53
3.50
3.81
3.72
3.62
3.60

Cap. MBtuh
Tot
45.6
41.6
37.2
35.9
46.2
42.4
38.2
37.6
46.7
43.1
39.1
39.0

Sen
20.4
25.2
29.5
30.6
21.2
26.7
31.5
32.0
21.9
28.1
33.4
33.2

Tot
Sys
Kw
3.91
3.80
3.66
3.62
3.98
3.89
3.77
3.75
4.07
3.96
3.86
3.86

CONDENSER AIR ENTERING Deg. F


105
115
95
Tot
Tot
Cap. MBtuh
Cap. MBtuh
Cap. MBtuh
Sys
Sys
Kw
Tot
Sen
Tot Sen Kw
Tot Sen
43.4 19.7 4.17
41.0 19.0 4.46 38.3 18.2
39.1 24.4 4.05
36.5 23.4 4.30 33.8 22.5
34.9 28.5 3.87
32.5 27.4 4.08 30.2 25.7
34.1 29.1 3.83
32.3 27.5 4.07 30.2 25.8
44.1 20.6 4.26
41.7 20.0 4.56 38.9 19.2
40.0 26.0 4.15
37.3 25.1 4.43 34.4 24.1
35.8 30.5 3.98
33.7 28.7 4.22 31.6 26.9
35.7 30.4 3.98
33.7 28.7 4.22 31.6 26.9
44.6 21.4 4.35
42.3 20.9 4.65 39.4 20.1
37.8 26.6 4.50 34.9 25.6
40.7 27.5 4.24
37.0 31.5 4.13
34.9 29.7 4.36 32.8 27.9
37.0 31.5 4.13
34.9 29.8 4.36 32.8 27.9

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

14

Tot
Sys
Kw
4.76
4.53
4.32
4.32
4.85
4.64
4.46
4.46
4.94
4.75
4.61
4.61

120
Cap.
MBtuh
Tot Sen
36.4 17.3
32.1 21.4
28.7 24.5
28.7 24.5
37.0 18.2
32.7 22.9
30.0 25.6
30.0 25.6
37.4 19.1
33.2 24.3
31.1 26.5
31.2 26.5

Tot
Sys
Kw
4.94
4.66
4.45
4.46
5.02
4.76
4.60
4.60
5.12
4.89
4.77
4.77

Detailed Performance Data

Nom Cap.
Mbtuh

600

36

700

800

700

48

800

900

1000

60

CONDENSER AIR ENTERING Deg. F

Evaporator
Air
CFM

1250

1500

EWB
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

38HK/HQ

Matching 38HK with Free Stand

75

85

Tot

Sen

Tot
Sys
Kw

40.7
37.7
34.1
32.4
41.2
38.4
34.9
33.9
41.6
38.8
35.6
35.1
52.3
48.4
43.8
41.7
53.0
49.3
44.9
43.6
53.5
49.9
45.8
45.1
68.5
63.4
57.3
54.5
69.4
64.6
58.7
57.1
70.1
65.4
59.9
59.1

20.8
25.9
30.5
32.1
21.5
27.3
32.5
33.6
22.1
28.6
34.3
34.7
23.2
28.8
34.0
35.7
24.0
30.4
36.3
37.4
24.7
31.9
38.3
38.7
34.1
42.3
49.8
52.4
35.2
44.6
53.2
54.9
36.2
46.7
56.1
56.8

3.29
3.21
3.12
3.08
3.37
3.29
3.20
3.17
3.45
3.37
3.28
3.26
3.87
3.77
3.67
3.62
3.96
3.87
3.76
3.73
4.06
3.96
3.86
3.83
5.03
4.91
4.77
4.71
5.15
5.03
4.89
4.85
5.28
5.15
5.02
4.99

Cap. MBtuh

95

Cap. MBtuh

Sen

Tot

19.7
24.4
28.5
29.1
20.6
26.0
30.5
30.4
21.4
27.5
31.5
31.5
22.0
27.2
31.8
32.4
23.0
29.0
34.1
33.9
23.9
30.7
35.1
35.2
32.3
39.8
46.6
47.5
33.7
42.5
49.9
49.7
35.0
45.0

3.78
3.67
3.51
3.47
3.86
3.76
3.61
3.61
3.94
3.84
3.74
3.74
4.44
4.31
4.13
4.08
4.54
4.42
4.24
4.24
4.63
4.51
4.40
4.40
5.78
5.61
5.37
5.31
5.90
5.75
5.52
5.52
6.03
5.87

51.5
51.5

5.72
5.72

35.3
31.5
28.0
27.8
35.9
32.1
29.0
29.0
36.4
32.6
30.1
30.1
45.4
40.4
36.0
35.7
46.2
41.3
37.3
37.3
46.8
41.9
38.7
38.7
59.4
53.0
47.2
46.8
60.5
54.1
48.8
48.8
61.3
54.8
50.6
50.6

Cap. MBtuh

Sen

Tot

20.4
25.2
29.5
30.6
21.2
26.7
31.5
32.0
21.9
28.1
33.4
33.2
22.7
28.1
32.9
34.1
23.6
29.8
35.2
35.7
24.4
31.4
37.2
37.1
33.3
41.2
48.2
50.0
34.6
43.7
51.6
52.3
35.7
46.0
54.5
54.3

3.54
3.44
3.32
3.28
3.61
3.52
3.42
3.40
3.69
3.59
3.50
3.50
4.16
4.04
3.90
3.86
4.24
4.14
4.02
4.00
4.34
4.22
4.11
4.11
5.41
5.26
5.08
5.02
5.52
5.38
5.23
5.20
5.64
5.49
5.35
5.35

37.4
33.7
30.1
29.4
38.0
34.5
30.9
30.7
38.4
35.0
31.8
31.9
48.1
43.3
38.7
37.8
48.9
44.3
39.7
39.5
49.4
45.0
40.9
41.0
62.9
56.7
50.6
49.4
64.0
58.0
51.9
51.8
64.7
59.0
53.6
53.6

Tot
39.3
35.8
32.1
30.9
39.8
36.5
32.9
32.3
40.2
37.1
33.7
33.6
50.5
46.1
41.2
39.8
51.2
47.0
42.3
41.6
51.7
47.7
43.4
43.2
66.1
60.3
54.0
52.1
67.0
61.5
55.4
54.4
67.7
62.4
56.8
56.6

105
Tot
Sys
Kw

Tot
Sys
Kw

Cap. MBtuh

115

120
Cap. MBtuh

Sen

Tot
Sys
Kw

Tot

Sen

Tot
Sys
Kw

18.2
22.5
25.7
25.8
19.2
24.1
26.9
26.9
20.1
25.6
27.9
27.9
20.3
25.1
28.7
28.7
21.4
26.9
30.0
30.1
22.4
28.6
31.2
31.2
29.7
36.8
42.1
42.1
31.3
39.4
44.0
44.0
32.8
41.8
45.7
45.7

4.31
4.10
3.91
3.91
4.39
4.20
4.04
4.04
4.48
4.30
4.18
4.18
5.07
4.82
4.60
4.60
5.16
4.94
4.75
4.75
5.27
5.05
4.91
4.91
6.59
6.27
5.98
5.98
6.71
6.42
6.18
6.18
6.85
6.58
6.39
6.39

16.5
14.6
13.0
13.0
16.8
14.8
13.6
13.6
17.0
15.0
14.1
14.1
21.2
18.7
16.7
16.7
21.6
19.1
17.5
17.5
21.8
19.3
18.2
18.2
27.8
24.5
21.9
21.9
28.2
25.0
22.9
22.9
28.6
25.3
23.8
23.8

9.1
11.3
12.9
12.9
9.6
12.0
13.5
13.5
10.0
12.8
14.0
14.0
10.1
12.5
14.4
14.4
10.7
13.4
15.0
15.0
11.2
14.3
15.6
15.6
14.9
18.4
21.0
21.1
15.7
19.7
22.0
22.0
16.4
20.9
22.8
22.8

4.47
4.22
4.04
4.04
4.55
4.31
4.17
4.17
4.64
4.43
4.32
4.32
5.26
4.96
4.74
4.75
5.34
5.07
4.90
4.90
5.46
5.21
5.08
5.08
6.84
6.45
6.17
6.18
6.95
6.60
6.38
6.38
7.10
6.78
6.60
6.60

Cap. MBtuh

Sen

Tot
Sys
Kw

Tot

19.0
23.4
27.4
27.5
20.0
25.1
28.7
28.7
20.9
26.6
29.7
29.8
21.2
26.1
30.5
30.7
22.3
28.0
32.0
32.0
23.3
29.7
33.2
33.2
31.1
38.3
44.7
44.9
32.6
41.0
46.9
46.9
34.1
43.5
48.6
48.6

4.04
3.90
3.70
3.69
4.13
4.01
3.82
3.82
4.21
4.08
3.95
3.95
4.75
4.58
4.35
4.34
4.85
4.71
4.49
4.49
4.95
4.80
4.64
4.64
6.18
5.96
5.66
5.64
6.32
6.13
5.84
5.84
6.44
6.24
6.04
6.04

33.0
29.1
26.0
26.0
33.5
29.6
27.2
27.2
33.9
30.1
28.2
28.2
42.4
37.4
33.5
33.5
43.1
38.1
35.0
35.0
43.6
38.7
36.3
36.3
55.5
49.0
43.8
43.8
56.4
49.9
45.8
45.9
57.1
50.6
47.5
47.5

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

15

38HK/HQ

Typical Wiring Schematic


38HK 18-36- 50Hz
220-240V/1Ph 24V Control

220-240V/1Ph 220V Control

16

38HK/HQ

Typical Wiring Schematic


38HK- 48-60 50Hz
400V/3Ph 24V Control

400V/3Ph 220V Control

17

38HK/HQ

Typical Wiring Schematic


38HK- 70
50Hz
400V/3Ph 24V Control

18

38HK/HQ

Typical Wiring Schematic


Heat Pump 38HQ18-24

19

Application data
Refrigerant lines
Unit selection
38HK/HQ

Select equipment to match or be slightly less


than anticipated peak load. This provides better
humidity control, fewer unit cycles, and less
part-load operation.
For units used in spaces with high sensible loads,
base equipment selection on unit sensible load,
not on total anticipated load. Adjust for
anticipated room wet bulb temperature to avoid
under sizing equipment.
When selecting equipment that has outdoor air
introduced into the unit, determine the mix
conditions of room air and outdoor air at design
conditions. The cooling capacity tables in this
literature are based on 80 F edb. To select the
proper equipment, adjust for actual dry-bulb and
wet-bulb conditions with the required outdoor
air.

Unit mounting
Unit leveling For reliable operation, units
should be level in all planes.
Clearance Provide adequate clearance for
airflow. See dimensional drawings for proper
clearances. The condensing units are designed
for free-blow application. Air inlets and outlets
should not be restricted. Outdoor fan external
static pressure available is less than 0.1 in. wg.
Unit location Units may be wall mounted, pad
mounted at ground level, roof mounted, or
mounted on or under a deck or patio. Be sure
that water from roof does not drain directly onto
the unit. If 38 Series condensing units are
mounted near a wall, the condenser air should
discharge away from the wall. This will provide
inherent coil protection and the best possible
sound and airflow performance.
Crankcase heater crankcase heaters used
to prevent refrigerant migration during
compressor off cycle (at very low ambient).

General refrigerant line sizing:


1. All charges, line sizing, and capacities are
based on runs of 25 ft. For runs over 25 ft,
consult the appendix A.
NOTE: The minimum line length should be 10 ft.
MAXIMUM LINE LENGTHS
UNIT

MAXIMUM
EQUIVALENT
FT

MAXIMUM LIFT
FAN COIL
BELOW
CONDENSING
UNIT

MAXIMUM LIFT
FAN COIL
ABOVE
CONDENSING
UNIT

38HK

50

30*

30*

*Maximum distance permitted is 30 ft from lowest


system component to highest system component. For
longer line application please refer to appendix A.

2. Refrigerant lines should not be buried in the


ground. If it is necessary to bury the lines, not
more than 36 in. should be buried. Provide a
minimum 6 in. vertical rise to the service valves
to prevent refrigerant migration.
3. The refrigerant lines must be insulated. Use a
minimum of 1/2-in. thick insulation. Closed-cell
insulation is recommended in all applications.
4. Special consideration should be given to
isolating interconnecting tubing from the building
structure. Isolate the tubing so that vibration or
noise is not transmitted into the structure.
5. The 38 Series system charge is based on rated
performance and 25 ft of line.
6. For the supply and return lines, check physical
data.
SYSTEM OPERATING CONDITIONS
OPERATING LIMITS
TEMPERATURE CONDITIONS
Maximum Cooling Ambient (F)
Minimum Cooling Ambient (F) (without
accessory low-ambient kit)
Minimum Cooling ambient (F) (with accessory
low-ambient kit)

55
35

Saturated Suction Temperature Range


Minimum (F) Maximum (F)

20 55

Saturated Condensing Temperature Range


Minimum (F) Maximum (F)

60 150

Maximum Compressor Discharge


Temperature (F)
Minimum Discharge Superheat (F)
NOTE: For system controls see Electrical Data.

20

LIMITS
125

275
60

38HK/HQ

Appendix
Long-Line Guideline.

Reference:
Catalog No. 513-868

21

LONG-LINE GUIDELINE

38HK/HQ

Table 1 REQUIRED FIELD INSTALLED


ACCESSORIES FOR AIR CONDITIONERS AND HEAT PUMP
REQUIRED FOR
LOW-AMBIENT APPLICATIONS
(BELOW 55F)

REQUIRED FOR
LONG-LINE
APPLICATIONS*
(OVER 50 FT)

REQUIRED FOR
SEA COAST
APPLICATIONS
(WITHIN 2 MILES)

Yes
Yes
Yes
No

Yes
No
No
No

No
No
No
No

Yes

Yes

No

Low Ambient Controller,


MotorMaster Control,
or
Low-Ambient Pressure Switch

Yes

No

No

Wind Baffle
Coastal Filter
Support Feet

See Low-Ambient Instructions


No
Recommended

No
No
No

No
Yes
Recommended

Liquid-Line Solenoid Valve


or
Hard-Shutoff TXV

No

See Long-Line
Application
Guideline

No

Ball-Bearing Fan Motor


Isolation Relay

Yes
Yes**

No
No

No
No

ACCESSORY

Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay

*For tubing line sets between 50 and 175 ft, refer to Residential Split-System Long-Line Application Guideline.
Only when low-pressure switch is used.
Required for Low-Ambient Controller (full modulation feature) and MotorMaster control only.
** Required on Heat Pumps only.

This Long-Line Application Guideline applies


to all Carrier residential air conditioner and
heat pump split systems that have a nominal
capacity of 18,000 to 60,000 Btuh. This
guideline provides required system changes
and accessories necessary for any residential
product having piping requirements greater
than 50 ft or installations where indoor unit is
located above outdoor unit.
This guideline is intended to cover applications
outside the standard Installation Instructions.
This guideline is for standard, single-speed
products. For applications involving 2-speed
products, refer to Step 6 first.
NOTE: The presale literature for outdoor unit
must be referred to in conjunction with this
guideline.
Step 1Approved Systems
Any
residential
indoor/outdoor
unit
combination listed in the outdoor unit presale
literature is an approved system, EXCEPT the
following:
Indoor coils with capillary-metering devices
All equipment less than nominal 18,000 Btuh

22

All 1/4-in. and 3/16in. liquid-line


applications
Any indoor furnace coil/fan coil not listed in
outdoor unit presale literature
Any application which has interconnecting
tubing with an equivalent length greater than
175 ft
Step 2Interconnecting Tubing Sizing
Table 2 lists recommended interconnecting
vapor-line diameters for equivalent total-line
lengths. All residential split systems installed
in long-line applications must use only 3/8-in.
liquid lines. Equivalent line length equals the
linear length (measured) of interconnecting
vapor tubing plus losses due to elbows. (See
Table 3 and Fig. 3.) Liquid lines larger than
3/8-in. OD greatly increase charge quantity of
the system. Excessive charge increases risk of
migration and compressor damage. Table 2
provides the estimated percentage of nominal
cooling-capacity losses based on the standard,
required vapor line size versus what is selected
for the long-line application. Since the vapor
line is the discharge line in heating mode,
losses are minimal.

Step 3Metering Device Sizing


The metering device for a long-line application
must be flexible enough to compensate for
frictional losses due to long refrigerant lines
and installed system design (indoor coil above
or below outdoor unit.) The piston or TXV
provides such flexibility.
The piston should be changed for both indoor
coil and outdoor heat pump unit, depending on
system configuration and line length. Tables 4
and 5 provide necessary changes for a given
application.
Use Tables 4 and 5 when selecting correct
piston size. Outdoor unit presale literature
must be consulted to determine metering
devices specified for standard applications.
After determining standard application piston
size(s), refer to Tables 4 and 5 as they relate to
system design (outdoor unit above or below
indoor unit) per equivalent length of tubing.
NOTE: If total equivalent horizontal length is
100 ft or longer, both indoor and outdoor
pistons must be increased 1 full piston size, in
addition to changes required by Tables 4 and 5.
After finding appropriate change in piston
size, add or subtract the change from original
piston number. If piston size is decreased,
round new piston number down to nearest
common piston number found in Table 6. If
piston size is increased, round new piston

number up to nearest common piston number


found in Table 6.
EXAMPLE:
An 042 size heat pump is 75 ft above an 042 size
fan coil. The 042 size heat-pump presale literature
specifies a size 80 indoor piston and size 63 outdoor
piston. To establish correct indoor piston size for a
75 ft vertical separation, refer to Table 4. For a 75 ft
equivalent line length, the piston change is -5.
Therefore subtract 5 from the original indoor piston
size of 80: 80 5 = 75
Table 6 provides common piston sizes. In this
instance, 75 is not listed, therefore round DOWN to
next piston size, which would be 74. To establish
correct outdoor piston size for a 75 ft vertical
separation, refer to Table 5. For a 75 ft equivalent
line length, the piston change is +4. Therefore add 4
to the original outdoor piston size of 63: 63 + 4 = 67
Since 67 is listed in Table 6, that is the piston which
should be used. If a 67 size piston were not listed, it
would be necessary to round UP to next piston size.

38HK/HQ

Calculate the linear length of vapor tube


required, adding any losses for the total
number of elbows for application. (See Table
6.) Using this equivalent length, select desired
vapor-line size from Table 2. Subtract the
nominal percentage loss from outdoor-unit
presale-literature Detailed Cooling Capacities
data for the given indoor/outdoor combination.
Reference all notes of Table 2.
NOTE:
When
specifying
vapor-line
insulation, be aware of the following standard
practice:
All standard accessory-tubing kits are supplied
with 3/8-in. insulation on vapor line.
For minimal capacity loss in long-line
application, 1/2-in. insulation should be
specified.
For reference only, the close cell insulation
material specified for accessory tubing kits is a
compound of vinyl, neoprene, or nitrile blends
of these polymers. Performance requirements
include thermal range of 0 F to 200F (-17.8
C to 93 C) and a maximum thermal
conductivity of 0.28.
NOTE: Special consideration must be given to
isolating interconnecting tubing from building
structure. Isolate tubing so that vibration or
noise is not transmitted into structure.

Step 4Liquid-Line Solenoid And


Tubing Configuration
There are 2 types of liquid-line solenoids: 1 for
single-flow applications and the other for biflow applications. The purpose of having 2
solenoids is to minimize the valve internalpressure drop in accordance with refrigerant
flow direction and liquid migration to the
compressor. The bi-flow solenoid is designed
to have minimal refrigerant-pressure drop in
either flow direction, which makes it suitable
for heat pump usage. Refer to Table 7 for
liquid-line solenoid kit part numbers.
NOTE: When installing a liquid-line solenoid,
the system may require a minimum 60-va lowvoltage transformer.
Each type of solenoid has an indicator flow
arrow stamped on the valve body. When
solenoid is closed (not energized) and pressure
is applied in direction of flow arrow, complete
shutoff occurs. If pressure is applied against
direction of flow arrow, leakage through valve
occurs. When determining proper installation
of valve within liquid line, 2 considerations
must be made:
1. Direction of flow arrow
2. Where solenoid is installed in system.
TXVs can only be substituted for liquid-line
solenoids in singleflow air conditioning
systems. Bi-flow TXVs allow liquid migration
to coldest point during off cycles, which could
allow liquid into compressor. Fig. 2 through 5
detail proper installation of liquid-line solenoid
and provide applications where TXVs may be
substituted. Reference all notes of the
appropriate figures.

23

38HK/HQ

Step 5Charging Information


Weigh in appropriate refrigerant charge, then
use the standard practices of superheatcharging method for piston applications and
subcooling-charging
method
for TXV
applications to confirm correct charge. The
standard charging methods can be found on
outdoor unit-information plate, in unit
Installation Instructions, or in the Service
Manual. Since total system charge is increased
for long-line applications, it may be necessary
to calculate the additional refrigerant charge.
Since long-line applications only involve 3/8in. liquid lines, the additional refrigerant
charge required is 0.6 oz of Refrigerant 22 (R22) per ft of 3/8-in. liquid line over 15 ft.

EXAMPLE:
To calculate additional charge required for a 25ft
line set: 25 ft 15 ft
= 10 ft X 0.6 oz/ft = 6 oz of additional charge

The rating-plate charge of a given outdoor unit


is for a standard application of 15 ft of
interconnecting tubing. The rating-plate charge
can be found on outdoor unit-rating plate or in
outdoor unit-presale literature. Long-line
applications do not require additional oil
charge.

Table 2 Estimated Percentage of Nominal Cooling-Capacity Losses*


UNIT NOMINAL
SIZE (BTUH)
18,000
24,000
30,000
36,000
42,000

48,000
60,000
70,000

LONG-LINE
VAPOR-LINE
DIAMETER (IN.)**
5/8
3/4
5/8
3/4
5/8
3/4
3/4
7/8
3/4
7/8
1-1/8
3/4
7/8
1-1/8
7/8
1-1/8
7/8
1-1/8

EQUIVALENT LINE LENGTH (FT)


50

75

100

125

150

175

5
1
6
0
6
2
7
2
7
3
0
10
4
0
7
1
7
1

7
3
9
1
8
3
10
4
10
4
0
14
6
0
9
2
9
2

9
4
13
1
10
4
14
6
13
6
1
18
7
1
11
2
11
2

12
5
16
2
13
5
17
8
17
7
1
22
9
1
14
3
14
3

12
5
19
3
15
6
21
10
20
8
2
NR
11
2
16
3
16
3

14
7
22
4
17
7
NR
11
23
10
2
NR
13
2
19
4
19
4

*The estimated percentage of cooling capacity that must be subtracted from the Detailed Cooling Capacities data specified in outdoor
unit-presale literature for any given indoor/outdoor combination.
**Vapor-line diameter that may be selected for a long-line application. If smaller vapor lines are selected but not specified within the
table, large capacity losses will occur and defrost capabilities will be reduced. If larger vapor lines are selected but not specified within
the table, refrigerant oil return will be impaired due to velocity losses.
N/RNot recommended due to excessive loss of capacity.

Step 62Speed Applications


Outdoor units may be connected to indoor
section using accessory tubing package or
field-supplied refrigerant grade tubing or
correct size and condition. In long-line
applications, 2speed units are handled
basically the same way as the single-speed
units. There are 2 major differences:
1. For tubing up to 100 ft: Liquid tube
diameters and refrigerant connection diameters
for all sizes are 3/8 in.

24

Vapor tube diameter for the 036 and 048 is 7/8


in.; 060 is 11/8
Vapor refrigerant connection diameter for all
sizes is 7/8 in.
DO
NOT
INSTALL
EQUIVALENT
INTERCONNECTING TUBING LENGTHS
GREATER THAN 100 FT.
2. Do not increase or decrease tubing sizes.
For other applications see the previous sections
under Long-Line Guidelines.

38HK/HQ

90 STD

45 STD

Fig.1Tube Bend Losses

Table 3Fitting Losses in Equivalent Ft


TUBE SIZE OD
(IN.)
5/8
3/4
7/8
1-1/8

A
1.6
1.8
2.0
2.6

REFERENCE DIAGRAM IN FIG. 1


B
1.0
1.2
1.4
1.7

C
0.8
0.9
1.0
1.3

25

Table 4 - Calculation of Indoor Piston No.


OUTDOOR UNIT ABOVE INDOOR

38HK/HQ

FT
0-25
26-50
51-75
76-100
101-125
126-150

PISTON CHANGE
0
-3
-5
-7
-9
-10
OUTDOOR UNIT BELOW INDOOR

FT
0-25
26-50

PISTON CHANGE
0
+4

Table 5 Calculation of Outdoor Piston No.


OUTDOOR UNIT ABOVE INDOOR
FT
0-50
51-75
76-100
101-125
126-150

PISTON CHANGE
0
+4
+6
+8
+10
OUTDOOR UNIT BELOW INDOOR

FT
0-50

PISTON CHANGE
0

Table 6 Common Piston Sizes


ACCURATER

35

38

40

42

46

49
51
52

55
57
59
61

63

CHATLEFF
32
33
35
36
37
38
39
40
41
42
43
45

47
49
51
52
53
55
57
59
61
62
63

ACCURATER
65
67

70

73

76
78
80

82
84
86
88

90

93
96
98
101
104
109

Table 7Liquid-Line Solenoid Kit Part Numbers


TYPE OF VALVE
Single Flow
Bi-Flow

26

PART NO.
KAALS0101LLS
KHALS0101LLS

CHATLEFF
65
67
68
70
71
73
74
76
78
80
81
82
84
86
88
89
90
92
93
96
98
101
104

38HK/HQ

175' MAX.

GROUND LEVEL

Note: For Rotary Compressor,


maximum length is 105'.
Scroll Max 200

BASEMENT

Fig. 2Application with Air Conditioner Installed in a Horizontal Configuration

175' MAX.

GROUND LEVEL

Note: For Rotary Compressor,


maximum length is 105'.
Scroll Max 200

BASEMENT

Fig. 3Application with Heat Pump Installed in a Horizontal Configuration

27

38HK/HQ

TRAP

50' MAX.

HEAT PUMP ONLY

GROUND LEVEL

Note: For Rotary Compressor,


maximum length is 30'.
Scroll Max 45

Fig. 4-Application with Air Conditioner or Heat Pump Installed with Indoor Unit above Outdoor Unit

HEAT PUMP ONLY

150' MAX.

Note: For Rotary Compressor,


maximum length is 90'.

Fig. 5Application with Air Conditioner or Heat Pump Installed Above Indoor Unit

38HK/HQ

NOTES

38HK/HQ

NOTES

38HK/HQ

NOTES

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations

2011

38HK-04 PD 50HZ