You are on page 1of 9

btsfaultcodes - bhardgrove

1/6/15, 3:03 PM

BTS Fault Codes

BTS fault codes


****** SO CF INTERNAL FAULT MAP CLASS 1A ******
Fault No Fault Type
CF-1A 1 Reset, Power on
CF-1A 2 Reset, Switch
CF-1A 3 Reset, Watchdog
CF-1A 4 Reset, SW fault
CF-1A 5 Reset, RAM fault
CF-1A 6 Reset, Internal function change
CF-1A 7 X bus fault
CF-1A 8 Timing unit VCO (Oscillator) fault
CF-1A 9 Timing bus fault
CF-1A 10 Indoor temp out of safe range
CF-1A 12 DC voltage out of range
CF-1A 14 Local bus related fault
CF-1A 15 IDB corrupt
CF-1A 16 RU database corrupt
CF-1A 17 HW and IDB inconsistent
CF-1A 18 Internal configuration failed
CF-1A 19 Indoor temp above safe range
CF-1A 20 Indoor temp below safe range
CF-1A 21 HW Fault
CF-1A 22 Air time counter lost
CF-1A 23 Time distribution fault
****** SO CF INTERNAL FAULT MAP CLASS 2A ******
Fault No Fault Type
CF-2A 1 Reset, Power on
CF-2A 2 Reset, Switch
CF-2A 3 Reset, Watchdog
CF-2A 4 Reset, SW fault
CF-2A 5 Reset, RAM fault
CF-2A 6 Reset, Internal function change
CF-2A 7 RXDA amplifier current fault
CF-2A 8
CF-2A 9

VSWR, Standing wave limits exceeded


Power Limit exceeded

https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 1 of 9

btsfaultcodes - bhardgrove

1/6/15, 3:03 PM

CF-2A 9 Power Limit exceeded


CF-2A 10 DXU-Opt EEPROM checksum fault
CF-2A 12 RX maxgain/mingain violation
CF-2A 13 Timing unit, VCO Oscillator ageing
CF-2A 14 CDU supervision/communication lost
CF-2A 15 VSWR/Output power supervision lost
CF-2A 16 Indoor temp out of normal conditional range
CF-2A 17 Indoor humidity
CF-2A 18 DC voltage out of range
CF-2A 19 Power and climate system in standalone mode
CF-2A 21 Internal power capacity reduced
CF-2A 22 Battery backup capacity reduced
CF-2A 23 Climate capacity reduced
CF-2A 24 HW fault
CF-2A 25 Loadfile missing in DXU or ECU
CF-2A 26 Climate sensor fault
CF-2A 27 System voltage sensor fault
CF-2A 28 A/D converter fault
CF-2A 29 Varistor fault
CF-2A 30 Local bus related fault
CF-2A 31 High frequency software fault
CF-2A 32 Non-volatile memory corrupt
CF-2A 33 RX diversity lost
CF-2A 34 Output voltage fault
CF-2A 35 Optional synchronization source
CF-2A 36 RU database corrupt
CF-2A 37 Circuit breaker tripped
CF-2A 38 Default values used
CF-2A 39 RX cable disconnected
CF-2A 40 Reset, DXU link lost
CF-2A 41 Lost communication TRU
CF-2A 42 LOst communication ECU
CF-2A 43 Internal configuratin failed
CF-2A 44 ESB distribution failure
CF-2A 45 High Temperature
CF-2A-46 DB Parameter Fault
CF-2A-47 Antenna Hopping Failure
CF-2A-48 GPS Synch Fault
CF-2A-49 Battery backup time shorter than expected
CF-2A-50 RBS running on battery
CF-2A-51 TMA supervision/communication lost
CF-2A-52 CXU supervision/communication lost
CF-2A-53 HW and IDB inconsistent
CF-2A-54 Timing Bus Fault
CF-2A-55 X Bus Fault
****** SO CF EXTERNAL CONDITION MAP CLASS 1B ******
Fault No Fault Type
EXT CF-1B 2 BTS locally disconnected
EXT CF-1B 4 L/R SWI (BTS in local mode)
https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 2 of 9

btsfaultcodes - bhardgrove

1/6/15, 3:03 PM

EXT CF-1B 4 L/R SWI (BTS in local mode)


EXT CF-1B 5 L/R TI (Local to remote while link lost)
***** SO CF EXTERNAL CONDITION MAP CLASS 2B ******
Fault No Fault Type
EXT CF-2B 9 RBS door open
EXT CF-2B 10 Mains Fail (external power source fail)
EXT CF-2B 11 ALNA/TMA fault
EXT CF-2B 12 ALNA/TMA Degraded
EXT CF-2B 13 Auxiliary equipment fault
EXT CF-2B 14 Battery Backup External Fuse Fault
****** SO CF, REPLACEMENT UNIT MAP ******
No.
RU
CF RU 0 DXU, Distribution switch unit
CF RU 1 ECU, Energy control unit
CF RU 2 Micro RBS
CF RU 3 Y link
CF RU 5 CDU, Combining and distribution unit
CF RU 6 CCU
CF RU 7 PSU, Power supply unit
CF RU 8
BFU
CF RU 9 BDM
CF RU 10 ACCU, AC connection unit
CF RU 11 Active cooler
CF RU 12 ALNA/TMA A, Antenna low noise amplifier
CF RU 13 ALNA/TMA B, Antenna low noise amplifier
CF RU 14 Battery
CF RU 15 Fan
CF RU 16 Heater
CF RU 17 Heat exchange Ext fan
CF RU 18 Heat exchange Int fan
CF RU 19 Humidity sensor
CF RU 20 TMA CM
CF RU 21 Temperature sensor
CF RU 22 CDU HLOUT HLIN cable
CF RU 23 CDU RX in cable
CF RU 24 Cooler Unit
CF RU 25 Distribution Unit
CF RU 26 Fuse Unit+
CF RU 27 FU CU PFWD Cable
CF RU 28 FU CU PREFL Cable
CF RU 29 CAB HLIN Cable
CF RU 30 CDU bus
CF RU 31 Environment or main switch
CF RU 32 Local bus
CF RU 33
CF RU 34
CF RU 36
CF RU 37
CF RU 38

Power communication loop


IDB
Timing bus
TX antenna A / CDU CXU RXA cable
TX antenna B / CDU CXU RXB cable

https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 3 of 9

btsfaultcodes - bhardgrove

CF RU 38
CF RU 39
CF RU 40
CF RU 41
CF RU 42
CF RU 45
CF RU 46
CF RU 47
CF RU 48
CF RU 49
CF RU 50
CF RU 51
CF RU 52
CF RU 53
CF RU 54
CF RU 55
CF RU 56
CF RU 57
CF RU 58

1/6/15, 3:03 PM

TX antenna B / CDU CXU RXB cable


XBUS
Antenna
PSU DC Cable
CXU
Battery Temp Sensor
FCU
TMA-CM Cable
GPS Receiver
GPS Receiver DXU Cable
Active Cooler Fan
BFU Fuse or Circuit Breaker
CDU CDU PFWD Cable
CDU CDU PREFL Cable
IOM Bus
ASU RXA unit or cable
ASU RXB unit or cable
ASU CDU RXA cable
ASU CDU RXB cable

****** SO TRXC INTERNAL FAULT MAP CLASS 1A *****


Fault No Fault Type
TRX-1A 0 Reset, Automatic recovery
TRX-1A 1 Reset, Power on
TRX-1A 2 Reset, Switch
TRX-1A 3 Reset, Watchdog
TRX-1A 4 Reset, SW fault
TRX-1A 5 Reset, RAM fault
TRX-1A 6 Reset, Internal function change
TRX-1A 7 Radio baseband loop test failed
TRX-1A 8 Timing reception fault
TRX-1A 9 Signal processing fault
TRX-1A 10 RX communication fault
TRX-1A 11 DSP CPU communication fault
TRX-1A 12 Terrestrial traffic channel fault
TRX-1A 13 RF loop test fault
TRX-1A 14 RU database corrupt
TRX-1A 15 XBUS communication fault
TRX-1A 16 Initiation fault
TRX-1A 17 X-interface fault
TRX-1A 18 DSP, Digital signal processor fault
TRX-1A 19 Reset, DXU link lost
TRX-1A 20 HW and IDB inconsistent
TRX-1A 21 Internal configuration failed
TRX-1A 22
TRX-1A 23
TRX-1A 24
TRX-1A 25
TRX-1A 26
TRX-1A 27

Voltage supply fault


Air time counter lost
High Temperature
TX/RX communication fault
Radio control system load
Traffic lost downlink

https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 4 of 9

btsfaultcodes - bhardgrove

TRX-1A 27
TRX-1A 28
TRX-1A 29
TRX-1A 30

1/6/15, 3:03 PM

Traffic lost downlink


Traffic lost uplink
Y link communication HW fault
DSP RAM soft error

****** SO TRXC INTERNAL FAULT MAP CLASS 1B ******


Fault No Fault Type
TRX-1B 0 CDU not usable(old)
TRX-1B 1 Indoor temp out of safe range
TRX-1B 3 DC voltage out of range
TRX-1B 4 Indoor temp above safe range
TRX-1B 5 Indoor temp below safe range
TRX-1B 7 TX address conflict
TRX-1B 8
Y Link Communication Fault
TRX-1B 9
Y link communication lost
TRX-1B 10 Timing Reception fault
TRX-1B 11 X Bus communication fault
****** SO TRXC INTERNAL FAULT MAP CLASS 2A ******
Fault No Fault Type
TRX-2A 0 RX cable disconnected
TRX-2A 1 RX EEPROM checksum fault
TRX-2A 2 RX Config table checksum fault
TRX-2A 3 RX Synthesizer unlocked
TRX-2A 4 RX Internal voltage fault
TRX-2A 5 RX communication fault
TRX-2A 6 TX communication fault
TRX-2A 7 TX EEPROM checksum fault
TRX-2A 8 TX Config table checksum fault
TRX-2A 9 TX Synthesizer unlocked
TRX-2A 10 TX Internal voltage fault
TRX-2A 11 TX High temperature
TRX-2A 12 TX Output power limits exceeded
TRX-2A 13 TX Saturation
TRX-2A 14 Voltage supply fault
TRX-2A 15 VSWR (Standing wave)/Output power supervision lost
TRX-2A 16 Non volatile memory corrupted
TRX-2A 17 Loadfile missing in tru
TRX-2A 18 DSP, Digital signal processor fault
TRX-2A 19 High frequency software fault
TRX-2A 20 RX initiation fault
TRX-2A 21 TX initiation fault
TRX-2A 22 CDU-bus communication fault
TRX-2A 23
TRX-2A 25
TRX-2A 26
TRX-2A 27
TRX-2A 29
TRX-2A 33
TRX-2A 36

Default values used


TX maximum poer restricted
Database parameter fault
RX path fault
Power Amplifier fault
Inter TRX communication fault
RX filter loadfile checksum fault

https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 5 of 9

btsfaultcodes - bhardgrove

TRX-2A 39
TRX-2A 40

1/6/15, 3:03 PM

RF loop test fault, degraded RX


Memory Fault

****** SO TRXC EXTERNAL CONDITION MAP CLASS 1 ******


Fault No Fault Type
EXT TRX-1B 4 L/R SWI (TRU in local mode or RBLT not available)
EXT TRX-1B 5 L/R TI (Local to remote while link lost)
****** SO TRXC, REPLACEMENT UNIT MAP ******
NO.
RU
TRX RU 0 TRU
TRX RU 3 CXU TRU RXA cable
TRX RU 4 CXU TRU RXB cable
TRX RU 10 CDU to TRU PFWD, Power Forward cable
TRX RU 11 CDU to TRU PREFL, Power Reflected cable
TRX RU 12 CDU to TRU RXA cable
TRX RU 13 CDU to TRU RXB cable
****** AO TS EXTERNAL CONDITION MAP CLASS 1 ******
Fault No Fault Type
EXT TS-1B 3 TRA (Remote transcoder com. lost)
****** AO TF INTERNAL FAULT MAP CLASS 1B ******
Fault No Fault Type
TF-1B 0 Optional synchronization source
TF-1B 1 DXU-opt. EEPROM checksum fault
***** AO TF EXTERNAL CONDITION MAP CLASS 1 ****
Fault No Fault Type
EXT TF-1B 0 EXT sync (no usable external reference)
EXT TF-1B 1 PCM sync (no usable PCM-reference)
****** AO TF EXTERNAL CONDITION MAP CLASS 2 ******
Fault No Fault Type
EXT TF-1B 0 EXT sync (no usable external reference)
EXT TF-2B 1 PCM sync (no usable PCM-reference)
****** AO TX INTERNAL FAULT MAP CLASS 1A ******
Fault No Fault Type
TX-1A 0
TX offending
****** AO TX INTERNAL FAULT MAP CLASS 1B ******
Fault No Fault Type
TX-1B 0
CU/CDU not usable
TX-1B 1
CDU VSWR, Standing wave limit exceeded
TX-1B 2
CDU Output power limits exceeded
TX-1B 4
TX Antenna VSWR, Standing wave limit exceeded
TX-1B 6
TX EEPROM checksum fault
TX-1B 7
TX Config table checksum fault
TX-1B 8
TX Synthesizer A/B unlocked
https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 6 of 9

btsfaultcodes - bhardgrove

TX-1B 8
TX-1B 9
TX-1B 10
TX-1B 11
TX-1B 12
TX-1B 13
TX-1B 14
TX-1B 17
TX-1B 18
TX-1B 19
TX-1B 20
TX-1B 21
TX-1B 22
TX-1B 23
TX-1B 24
TX-1B 25
TX-1B 26
TX-1B 27
TX-1B 28
TX-1B 31
TX-1B 32
TX-1B 33
TX-1B 34
TX-1B 47

1/6/15, 3:03 PM

TX Synthesizer A/B unlocked


TX Synthesizer C unlocked
TX communication fault
TX Internal voltage fault
TX High temperature
TX Output power limits exceeded
TX Saturation
TX Initiation fault
Hw fault
Sw load/start fault
Input power fault
Park fault
VSWR/Output power supervision lost
Reset, Power on
Reset, communication fault
Reset, watchdog
Fine tuning fault
TX max power restricted
TCU high temperature
Power Amplifier Fault
TX low temperature
CDU-bus communication fault
Y link Xbus collision fault
TX auxiliary equipment fault

****** AO TX INTERNAL FAULT MAP CLASS 2A


Fault No Fault Type
TX-2A 0
TX diversity lost
****** AO RX INTERNAL FAULT MAP CLASS 2A ******
RX-2A 0 CXU Supervision/Communication Fault
RX-2A 1 RX path lost on A receiver side
RX-2A 2 RX Path lost on B receiver side
RX-2A 3 RX Path lost on C receiver side
RX-2A 4 RX Path lost on D receiver side
****** AO RX INTERNAL FAULT MAP CLASS 1B ******
RX-1A 0 RX path lost on A receiver side
****** AO RX INTERNAL FAULT MAP CLASS 1B ******
Fault No
RX-1B 0
RX-1B 1
RX-1B 3
RX-1B 4
RX-1B 5
RX-1B 6
RX-1B 7
RX-1B 8
RX-1B 9

Fault Type
RX internal amplifier fault
ALNA/TMA fault , Antenna low noice amplifier fault
RX EEPROM checksum fault
RX Config table checksum fault
RX Synthesizer A/B unlocked
RX Synthesizer C unlocked
RX communication fault
RX Internal voltage fault
RX cable disconnected

https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 7 of 9

btsfaultcodes - bhardgrove

RX-1B 10
RX-1B 11
RX-1B 12
RX-1B 13
RX-1B 14
RX-1B 15
RX-1B 17
RX-1B 18
RX-1B 19
RX-1B 47

1/6/15, 3:03 PM

RX Initiation fault
CDU Output voltage fault
TMA output voltage fault
RX path fault
CDU Supervison/ Communication fault
RX High Temperature
TMA Supervision Fault
TMA Power Distribution Fault
RX filter loadfile checksum fault
RX Auxiiart Equipment Fault

****** AO CON EXTERNAL CONDITION map class 1 ******


CON-2A 8 LAPD Q CG(LAPD Que congestion)
********** TERMINOLOGY **********
INTERNAL FAULT MAP CLASS 1A: Affect MO functionality.
Faulty HW is part of the signaling MO.
INTERNAL FAULT MAP CLASS 1B: Affect MO functionality.
Origin of the fault is external to the signaling MO.
INTERNAL FAULT MAP CLASS 2A: Not affect MO functionality.
Faulty HW is part of the signaling MO.
EXTERNAL CONDITION MAP CLASS 1: Affect MO functionality.
The conditions are TG external.
EXTERNAL CONDITION MAP CLASS 2: Not affect MO functionality.
The conditions are TG external.
REPLACEMENT UNIT MAP (RU MAP): Suspected HW causing the faults
in internal fault maps.
MO: Mangaged Object, the class of all object in the BTS O&M
model which BSC can communicate with.
SO: Service Object, an abstract subclass of MO which handles
HW. A SO manages one or more RUs.
AO: Application Object, an abstract subclass of MO which only
handles functionality.
RU: Replaceable Unit, Smallest unit in a RBS2000 cabinet
which can be replaced.
LOGICAL RU: A unit which can be refered to but is not a single
pysical unit. There are tree different kinds of logical RUs:
1. BUSSES
-XBUS
-LOCAL BUS
https://sites.google.com/site/bhardgrove/btsfaultcodes

Page 8 of 9

btsfaultcodes - bhardgrove

1/6/15, 3:03 PM

-LOCAL BUS
-TIMING BUS
-CDU BUS
-POWER COMMUNICATION LOOP
2. ANTENNAS -RX A
-RX B
-TX A
-TX B
3. ENVIRONMENT -TEMPERATURE
****** DIGITAL PATH FAULTS ******
DIP fault 1 Alarm indication signal AIS
DIP fault 2 Loss of frame alignment
DIP fault 3 Excessive error rate
DIP fault 4 Alarm indication from the remote end
DIP fault 5 Alarm indication signal in time slot 16
DIP fault 6 Loss of multiframe alignment
DIP fault 7 Alarm ind. from remote end signalling equipment
DIP fault 8 Alarm indication signal ALL1
DIP fault 9 Loss of CRC multiframe alignment
DIP fault 10 Consectutive severely errrored seconds
****************************************************
(T1 can be loop inlet to DXU 6+7 and 8+9)