You are on page 1of 5

www.hilti.

in
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.3.4


Page:
Project:
Fastening point:
Date:

1
?AS
06/01/2015

Specifiers comments:

Design standard:

EC2 / ETA

Application type:

Standard applications/Compression

1. Loads for yielding of the bar

2. Drilling & Temperature

3. Material & Safety

Loads

Drilling

Structure

Top

0 kN/bar

Hole condition

Dry

Concrete class (existing structure)

C20/25

Bottom

0 kN/bar

Drilling method

Hammer drilling

Char. yield strength (existing)

500 N/mm

Drilling aid

Drilling aid is used

Char. yield strength (new)

500 N/mm

Fire design
Fire rating

None

Temperature (EC2/ETA)

Fatigue design

During installation

from 5 C to 40 C

None

During service

20 C / 20 C

Seismic
Seismic loads

No

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.3.4


Page:
Project:
Fastening point:
Date:

4. Eurocode 2 parameters

2
?AS
06/01/2015

5. Post-installed reinforcement

cc

1.00

Number of layers

ct

1.00

Number of top layers

Number of bottom layers

ct,bond

1.00

Top reinforcements parameters

ud

0.020

Top diameter

10 mm

k2

0.85

Top spacing

200 mm

'

0.92

Top layer 1: c

50 mm

max

0.04

Top layer 1: cd (EC2, 8.4.4.1)

95 mm

c2

0.002

Top bond condition

Good

c2u

0.0035

Top min. reinforcement

100 mm/m

Bottom reinforcements parameters


Bottom diameter

10 mm

Bottom spacing

200 mm

Bottom layer 1: c

50 mm

Bottom layer 1: cd (EC2, 8.4.4.1)

95 mm

Bottom bond condition

Good

Bottom min. reinforcement

100 mm/m

Other
Transverse pressure

0 N/mm

Cover of tension force line b

0 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in

Hilti PROFIS Rebar 2.3.4

Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Page:
Project:
Fastening point:
Date:

3
?AS
06/01/2015

Selected solution
Bar size

Drill bit size

Bar spacing
centre/centre

Distance
centre/surface

Drilled hole
required

Anchorage for
yield of bar

[mm]

D [mm]

s [mm]

cs [mm]

vreq [mm]

vy [mm]

Layer of bars
Top / left

10

14

200

2,055

331

331

Bottom / right

10

14

200

2,055

331

331

Required accessories
Drilling

Cleaning

- Suitable rotary hammer


- Properly sized drill bit

- Compressed air with required accessories to - Dispenser including cassette and mixer
blow from the bottom of the hole
- For deep installations, a piston plug is
- Proper diameter wire brush
necessary

Setting

Upper layer (compression side)


Design Input
Design force in bar

FE = As,rqrd * fyd/s 0

-170.74 kN/m

Provided reinforcement

= 10 mm, s = 200 mm As,prov

Stress in bars

sd = FE/As,prov = fyd

Adhesive used

Hilti HIT-HY 200

393 mm/m
434.8 N/mm

Design for yield

Anchorage Post-Installed Reinforcement


Bond condition

Good 1

1.0

(input)

Bond strength

fbd,pi

2.3 N/mm

ETA 11/0492

Basic anchorage length

lb,rqd = (/4)(sd/fbd,pi)

473 mm

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,pi)

473 mm

Factor for minimum length

fmult,min

1.0

Minimum anchorage length

l0,min = fmult,minmax(0.6lb,rqd,fyd; 10; 100 mm)

284 mm

Min of clear cover or half spacing

cd

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.7lb,rqd/st)

0 mm

Min. transverse reinforcement

Ast,min = (EN 1992-1-1, table 8.2)

0 mm

K-factor

K = (EN 1992-1-1, table 8.2)

95 mm
0.70

0.05
2

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/( /4) 1.0}

Transverse pressure

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Design anchorage length

lbd = max(lb,rqd; lb,min)

331 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1.00

0 N/mm

www.hilti.in
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.3.4


Page:
Project:
Fastening point:
Date:

4
?AS
06/01/2015

Definition of the installation length


Controlling anchorage length

lbd

331 mm

Installation length

linst = lbd

331 mm

Lower layer (compression side)


Design Input
Design force in bar

FE = As,rqrd * fyd/s 0

-170.74 kN/m

Provided reinforcement

= 10 mm, s = 200 mm As,prov

Stress in bars

sd = FE/As,prov = fyd

Adhesive used

Hilti HIT-HY 200

393 mm/m
434.8 N/mm

Design for yield

Anchorage Post-Installed Reinforcement


Bond condition

Good 1

1.0

(input)

Bond strength

fbd,pi

2.3 N/mm

ETA 11/0492

Basic anchorage length

lb,rqd = (/4)(sd/fbd,pi)

473 mm

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,pi)

473 mm

Factor for minimum length

fmult,min

1.0

Minimum anchorage length

l0,min = fmult,minmax(0.6lb,rqd,fyd; 10; 100 mm)

284 mm

Min of clear cover or half spacing

cd

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.7lb,rqd/st)

0 mm

Min. transverse reinforcement

Ast,min = (EN 1992-1-1, table 8.2)

0 mm

K-factor

K = (EN 1992-1-1, table 8.2)

95 mm
0.70

0.05
2

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/( /4) 1.0}

1.00

Transverse pressure

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Design anchorage length

lbd = max(lb,rqd; lb,min)

331 mm

lbd

331 mm

0 N/mm

Definition of the installation length


Controlling anchorage length

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
Installation length

Hilti PROFIS Rebar 2.3.4


Page:
Project:
Fastening point:
Date:

|
linst = lbd

5
?AS
06/01/2015
331 mm

Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and
existing concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that
adequate transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The Installation (drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan