Single Power Supply


Slim Line AC-DC Redundant Module
AC-DC Redundant Module
High Voltage AC / DC - DC Dual - Input
DC-DC Redundant Module
Backup Battery
CRPS Redundant Module
Blade Server Module
201406

www.compuware.com.tw

Green Server Power Supply

ABOUT Compuware
Compuware is a global leading company of Green Power Supply design and manufacturing.
The company has dedicated inTechnology Innovation, Green Environment, Module Structureas its development cores.
It has professional RD teams, high quality production capabilities, solutions for diversied requirements of power supplies.
It also provides competitive and extraordinary products, which makes it the most reliable partner for its customers and suppliers,
and creates the best product competition for its customers.
Compuware continues to develop green power supplies with the most advanced technologies.
It has aggressively introduced digital control design into its products structure, with higher than 96% Power Eciency. It has
accumulated long-term development technology for Power Supplies to more application areas, including Cloud Computing
Servers, Networking Equipments, Industrial PCs, Blade Servers, NAS Storage Products, Telecommunication Products... ... those
perspective products, and so on.
In accordance to the demands of Green Data Centers, Compuware uses Green Technology to create Green Power Supplies
through practical actions in response to environmental protection. It has built an international Green Image Brand and has
fullled its corporate social responsibility.

Company Profile

2004

80Plus96%

01

Company Profile

China Branch, Beijing


US Branch, Fremont

China Factory, Shenzhen


Headquarters, Taipei, Taiwan


Taiwan Factory, Bade


Global Location

02

Headquarters, Taipei, Taiwan

Taiwan Factory, Bade

US Branch, Fremont

, ,

5F, No.232, Liancheng Rd., Zhonghe District,


New Taipei City 235,Taiwan R.O.C.
2325 ()
TEL+ 886-2-8226-3936
FAX+ 886-2-8226-3937
E-mailsales@compuware.com.tw

3F., No.306, Changan St., Bade City,


Taoyuan County 334, Taiwan R.O.C.
3063
TEL+ 886-2-8226-3936
FAX+ 886-2-8226-3937

48293 Fremont Blvd., Fremont, CA 94538


E-mailsupport@compuware-us.com

China Branch, Beijing

China Factory, Shenzhen

Room 3-801 Jinquan Times Plaza ,No. 317 Datunli ,


Chaoyang District, Beijing, P.R.China
3173-801
TEL+ 86-10-82427375
FAX+ 86-10-82427378

No.12069, Shennan Rd.,Nanshan District,


Shenzhen City , P.R.China
12069
2721
TEL+ 86-755-83458542
FAX+ 86-755-83458617

www.compuware.com.tw

Green Server Power Supply

High Quality
Manufacturing

Compuware provides its employees a Carton Reduction, Optimal and Comfortable working environment, which is compliant with
international standards of environmental management systems, to ensure the Working Safety and Health of its employees. It has
entirely accomplished energy-saving and environment continuity concepts.
Compuware provides sucient production capability and produces high quality products for its customers by adopting consistent
production processes and integral production equipments. Its outstanding production yield rate satises customers demands and
makes it the best partner for its customers.

03

New Power Supply

80Plus Titanium Power


Digital Power Supply
High Power Density 48 W/in3
Highest Efficiency Higher than 96%
Supporting PMBus 1.2 communication protocol

High Efficiency

P.31

CPR-1621-4M1
Dimension346 x 76 x 40 mm

CPR-1021-6M1
(DxWxH)

Total Max Power800W @ 100 - 140Vac


1600W @ 180 - 264Vac

04

P.42

Dimension185 x 73 x 40 mm
Total Max Power1000W

(DxWxH)

www.compuware.com.tw

Green Server Power Supply

High Technology
Compuware has overturned the Power Structures of Global Data Centers for Cloud Computing applications. It has penetrated the cloud
computing business by integrating Power Supplies and Backup Battery Solutions, and has said Good-Bye to the UPS Uninterruptable Power
Supply Systems.
UPS

P.41

CPR-2011-1M1

Dimension220 x 54.5 x40 mm

P.41

CPR-1021-4M1
(DxWxH)

Total Output Power200W / 5 minutes

Dimension346 X 76 X 40 mm

(DxWxH)

Total Output Power1000W / 2.5 minutes


05

Building Block Solution

AC-DC
Redundant Module
500W- 2000W

DC-DC 48V
Redundant Module

Mix
&
Match

710W- 1010W

High Voltage
AC / DC - DC Dual - Input

Application
Optimized!

1280W

Backup Battery
1000W

Slim Line AC-DC


Redundant Module
400W - 700W

Slim Line DC-DC


600W

High Voltage
AC / DC - DC Dual - Input
700W

Backup Battery
200W

06

Mix
&
Match

Application
Optimized!

www.compuware.com.tw

Contents
NAME OF SERIES

1U Single

2U Single

Slim Line AC-DC


Redundant Module

Redundant Module

High Voltage
AC / DC - DC Dual - Input

DC-DC
Redundant Module

Backup Battery

CRPS

Blade Server Module

Watt

80PLUS

PMBus

EMI

Depth

Width

Height

Page

CPS-2511-1A1

250

Bronze

Class B

150

81

40

P8

CPS-3511-2A1LF

350

Gold

Class B

220

100

40

P9

CPS-4211-1A1

420

Gold

Class A

220

100

40

P 10

CPS-4411-1A1

440

Platinum

1.2

Class B

220

100

40

P 11

CPS-6011-2A1LF

600

Gold

Class B

220

100

40

P 12

CPS-6811-2A1

680

Gold

Class B

220

100

40

P 13

CPS-6512-2A1

650

Gold

Class A

300

106

83

P 14

CPR-4011-4M1/2

400

Gold

1.2

Class A

220

54.5

40

P 15

CPR-5011-2M1LF

500

Platinum

1.2

Class A

322

54.5

40

P 16

CPR-5011-2M2LF

500

Platinum

1.2

Class A

322

50

40

P 16

CPR-6011-2M1 / 2

600

Platinum

1.2

Class A

220

54.5

40

P 17

CPR-7011-5M1LF

700

Gold

0.3

Class A

322

54.5

40

P 18

50

40

P 18

MODEL NAME

CPR-7011-5M2LF

700

Gold

0.3

Class A

322

CPR-9811-1M1

980

Platinum

1.2

Class A

322

54.5

40

P 19

CPR-5011-3M1

500

Platinum

1.2

Class A

346

76

40

P 20

CPR-7011-6M1

700

Platinum

1.2

Class A

346

76

40

P 21

CPR-7211-1M1LF

720

Gold

1.1

Class A

346

76

40

P 22

CPR-7411-1M1

740

Platinum

1.2

Class A

346

76

40

P 23

CPR-7411-1M2

740

Platinum

1.2

Class A

346

76

40

P 24

CPR-9211-1M1LF

920

Platinum

1.2

Class A

346

76

40

P 25

CPR-9211-1M2LF

920

Platinum

1.2

Class B

346

76

40

P 25

CPR-1221-1M2LF

1200

Gold

1.1

Class A

346

76

40

P 26

CPR-1221-5M1

1280

Platinum

1.2

Class B

346

76

40

P 27

CPR-1421-1M2LF

1400

Gold

1.1

Class A

298

104.5

40

P 28

CPR-1421-2M1LF

1400

Gold

1.1

Class A

346

76

40

P 29

CPR-1421-2M2LF

1400

Gold

1.1

Class B

346

76

40

P 29

CPR-1421-5M1

1400

Platinum

1.2

Class A

298

104.5

40

P 30

CPR-1621-4M1

1600

Titanium

1.2

Class A

346

76

40

P 31

76

40

P 32

CPR-1621-1M2 / 4

1620

Platinum

1.1

Class A

346

CPR-1821-1M1

1800

Platinum

1.2

Class A

305

91

40

P 33

CPR-2021-1M1

2000

Platinum

1.2

Class A

346

76

40

P 34

CDR-7011-1M1

700

Platinum

1.2

Class A

322

54.5

40

P 35

CDR-7011-1M2

700

Platinum

1.2

Class A

322

50

40

P 35

CDR-1221-1M1

1280

Platinum

1.2

Class B

346

76

40

P 36

CDR-6611-1M1

660

92%

1.2

Class A

322

50

40

P 37

CDR-7111-1M1LF

710

89%

Class A

346

76

40

P 38

CDR-1021-1M1LF

1010

89%

1.1

Class A

346

76

40

P 39

CPR-2011-1M1

200

Class A

220

54.5

40

P 41

CPR-1021-4M1

1000

Class A

346

76

40

P 41

CPR-1021-6M1

1000

Titanium

1.2

Class A

185

73

40

P 42

CPR-1821-4M1

1820

Platinum

1.2

Class A

265

73

40

P 43

CPR-2021-2M1

2000

Platinum

1.2

Class A

265

73

40

P 44

CPR-1627-2M1

1600

Platinum

1.2

Class A

241.3

106.6

82

P 45

CPR-1627-1M1LF

1620

Class A

241.3

216

100

P 46

257.3

216

100

P 47

257.3

216

100

CPR-2527-1M2LF

2500

Platinum

Class A

CPR-3027-1M1

3000

Platinum

Class A

Contents

AC-DC

Green Server Power Supply

P 48
Dimensionmm

07

1U Single

FEATURES
80Plus Bronze
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , Networking , IPC

CPS-2511-1A1
Dimension150 x 81 x 40 mm
Total Max Power250W

(DxWxH)

(FlexATX)

UL , cUL , TUV , CB , FCC Class B , CISPR Class B , Meet CE , RoHS

1U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

3.5 - 1.5A

GENERAL SPECIFICATIONS
Hold-up time

16ms @ 75% Load

Efficiency

over 80% @ all Load

MTBF

100,000 hours at 75% load and 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 40 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

0% to 85% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V1

+12V2

-12Vsb

+5Vsb

Regulation

5%

5%

5%

5%

10%

5%

Max Load

13A

14A

18A

18A

0.3A

2.0A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

1. Maximum continuous total DC output power should not exceed 250W


2. Maximum combined continuous power of 5V and 3.3V should not exceed 80W.

08

1U Single

www.compuware.com.tw

Green Server Power Supply

FEATURES
80Plus Gold
Highest efficiency 90%
Active Power Factor Correction
Meets ENERGY STAR 5.0
RoHS compliant for all six substances
Application for Server , Storage , Networking , IPC

CPS-3511-2A1LF
Dimension220 x 100 x 40 mm

(DxWxH)

Total Max Power350 W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B , Meet CE , RoHS

1U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

4.2 - 1.8A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 90% @ 50% Load

MTBF

200,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

15A

18A

29A

0.5A

3.0A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

1. Maximum continuous total DC output power should not exceed 350W


2. Maximum combined continuous power of 5V and 3.3V should not exceed 100W.

09

1U Single

FEATURES
80Plus Gold
Highest efficiency 90%
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , Networking, IPC

CPS-4211-1A1
Dimension220 x 100 x 40 mm

(DxWxH)

Total Max Power350W @ 90 - 140Vac


420W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

1U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

4.2 - 2.0A

GENERAL SPECIFICATIONS
Hold-up time

15ms @ 75% Load

Efficiency

at least 90% @ 50% Load

MTBF

200,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

15A

18A

29A @ 90 - 140Vac
35A @ 180 - 264Vac

0.5A

3.0A

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

10

50
50
mVp-p mVp-p

1. Maximum continuous total DC output power should not exceed 350W @ 90-140Vac
2. Maximum continuous total DC output power should not exceed 420W @ 180-264Vac
3. Maximum combined continuous power of 5V and 3.3V should not exceed 100W

1U Single

www.compuware.com.tw

Green Server Power Supply

FEATURES
Support PMBus 1.2
80Plus Platinum
Highest efficiency 92%
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , Networking , IPC

CPS-4411-1A1
Dimension220 x 100 x 40 mm

(DxWxH)

Total Max Power440W @ 90 - 140Vac


480W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B , Meet CE , RoHS , REACH

1U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

4.7 - 2.0A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 92% @ 50% Load

MTBF

200,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

15A

18A

35.8A @ 115Vac
39.1A @ 230Vac

0.5A

3A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

1. Maximum continuous total DC output power should not exceed 440W with 115Vac and
480W with 230Vac
2. Maximum combined continuous power of 5V and 3.3V should not exceed 100W

11

1U Single

FEATURES
80Plus Gold
Highest efficiency above 91%
Active Power Factor Correction
Meets ENERGY STAR 5.0
RoHS compliant for all six substances
Application for Server , Storage , Networking , IPC

CPS-6011-2A1LF
Dimension220 x 100 x 40 mm

(DxWxH)

Total Max Power600W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B , Meet CE , RoHS

1U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

7.5 - 3.1A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 91% @ 50% Load

MTBF

200,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

16A

20A

49A

0.5A

3.0A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

1. Maximum continuous total DC output power should not exceed 600W


2. Maximum combined continuous power of 5V and 3.3V should not exceed 140W

12

1U Single

www.compuware.com.tw

Green Server Power Supply

FEATURES
80Plus Gold
Highest efficiency 90%
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , Networking, IPC

CPS-6811-2A1
Dimension220 x 100 x 40 mm

(DxWxH)

Total Max Power600W @ 90 - 140Vac


680W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B , Meet CE , RoHS

1U Single

INPUT SPECIFICATIONS
Input voltage

90- 264Vac

Input frequency

47 - 63Hz

Input current

600W @ 7.5 - 5.2A /

680W @ 4.5 - 3.5A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 90% @ 50% Load

MTBF

200,000 hours at 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

16A

20A

49A @ 90 - 140Vac
56A @180 - 264Vac

0.5A

3A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

1. Maximum continuous total DC output power should not exceed 600W at low input AC line
2. Maximum continuous total DC output power should not exceed 680W at high input AC line
3. Maximum combined continuous power of 5V and 3.3V should not exceed 140W

13

2U Single

FEATURES
80Plus Gold
Highest efficiency 90%
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage

CPS-6512-2A1
Dimension300 x 106 x 83 mm

(DxWxH)

Total Max Power600W @ 90 - 140Vac


650W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC ClassA , CISPR Class A , meet CE


RoHS , REACH , Meet EUP

2U Single

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

8.0 - 3.3A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 90% @ 50% Load

MTBF

200,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

Regulation

5%

5%

5%

10%

5%

Max Load

25A

30A

49A @ 90 - 140Vac
54A @ 180 - 264Vac

0.5A

3.0A

50
mVp-p

50
mVp-p

120
mVp-p

120
mVp-p

50
mVp-p

Ripple & Noise


Note

14

1. Maximum continuous total DC output power should not exceed 600W@(90-140Vac)


2. Maximum continuous total DC output power should not exceed 650W@(180-264Vac)
3. Maximum combined continuous power of 5V and 3.3V should not exceed 160W.

Slim Line AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus1.2

High Power Density 15 W/in3

80Plus Gold
Highest efficiency 93%@230Vac
Active Power Factor Correction
Air flow from AC inlet side to gold finger side (CPR-4011-4M2)
Application for Embedded server , Storage , Networking , IPC

CPR-4011-4M1/4M2
Dimension220 x 54.5 x 40 mm

(DxWxH)

Total Max Power400 W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Slim Line AC-DC

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

6.0 - 3.0A

GENERAL SPECIFICATIONS
Hold-up time

12ms @ 100% Load

Efficiency

at least 93% @ 50% Load

MTBF

Normal operation at 25 degree Celsius: 150,000h

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

33A

3.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 400W continuously for 90 to 264VAC input
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
3. Under no load or minimum load condition, the power supply must be able to power on or off successfully

15

Slim Line AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density

80Plus Platinum

Highest efficiency 94%

Active Power Factor Correction


RoHS compliant for all six substances

CPR-5011-2M1LF / 2M2LF
Dimension322 x 54.5 x 40 mm ( D x W x H )
322 x 50 x 40 mm (CPR-5011-2M2LF)

Application for Server , Storage , Industrial

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Total Max Power500W


Slim Line AC-DC

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63 Hz

Input current

7.4 - 2.2A

GENERAL SPECIFICATIONS
Hold-up time

20ms @ 75% Load

Efficiency

at least above 94% @ 50% Load

MTBF

50,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

42A

4.0A

120mVp-p

50mVp-p

Ripple & Noise

Drawing : CPR-5011-2M1LF

Note

16

1. The total output power can not exceed 500W continuously for 90 to 264Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

Slim Line AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 23W/in3

80Plus Platinum

Highest efficiency 94%

Active Power Factor Correction


Air flow from AC inlet side to gold finger side (CPR-6011-2M2)

CPR-6011-2M1 / 2M2
Dimension220 x 54.5 x 40 mm

Application for Embedded server , Storage , Networking , IPC

(DxWxH)

Total Max Power600 W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A, Meet CE , RoHS

Slim Line AC-DC

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

7.8 - 2.7A

GENERAL SPECIFICATIONS
Hold-up time

12ms @ 100% Load

Efficiency

at least 94% @ 50% Load

MTBF

100,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

50A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 600W continuously for 90 to 264Vac input
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
3. Under no load or minimum load condition, the power supply must be able to power on or off successfully

17

Slim Line AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 0.3

High Power Density

80Plus Gold

Highest efficiency 93%

Active Power Factor Correction


RoHS compliant for all six substances

CPR-7011-5M1LF / 5M2LF
Dimension322 x 54.5 x 40 mm ( D x W x H )
322 x 50 x 40 mm (CPR-7011-5M2LF)

Application for Server , Storage

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Total Max Power700W


Slim Line AC-DC

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63 Hz

Input current

11.0 - 3.0A

GENERAL SPECIFICATIONS
Hold-up time

19ms @ 75% Load

Efficiency

at least 93% @ 50% Load

MTBF

50,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

58A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

18

1. The total output power can not exceed 700W continuously for 90 to 180Vac input and 750W
continuously for 180 to 264Vac
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

Drawing : CPR-7011-5M1LF

Slim Line AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal ORing

N+1 Redundant

Support PMBus 1.2

High Power Density 22W/in3

80Plus Platinum

Highest Efficiency 94%

Active Power Factor Correction


RoHS compliant for all six substances
Application for Server, Storage

CPR-9811-1M1
Dimension322 x 54.5 x 40 mm

(DxWxH)

Total Max Power850W @ 90 - 140Vac


980W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Slim Line AC-DC

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

12.0 - 4.5A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% load

MTBF

50,000 hours at 100% load and 50 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

70A @ 90 - 140Vac
81A @ 180 - 264Vac

4.0 A
(peak 6A)

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 850W continuously for 90 to 140Vac input
2. The total output power can not exceed 980W continuously for 180 to 264Vac input
3. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
4. Under no load or minimum load condition, the power supply must be able to power on or off successfully

19

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2


80Plus Platinum
Highest efficiency above 94% @ 230VAC
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , Industrial

CPR-5011-3M1
Dimension346 x 76 x 40 mm ( D x W x H )
Total Max Power500W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63 Hz

Input current

11.0 - 3.5A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

41.7A

4.0A

120mVp-p

50mVp-p

Ripple & Noise

Note

20

1. The total output power can not exceed 500W continuously for 90 to 264Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing
N+1 Redundant
Support PMBus 1.2
80Plus Platinum
Active Power Factor Correction
Application for Server , Storage

CPR-7011-6M1
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power500W @ 100 - 240Vac


700W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63 Hz

Input current

7.0 - 3.5A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

94% typical at high line 50% load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

41.7A @ 90 - 140Vac
58.3A @ 180 - 264Vac

4.0A(90 - 264V)

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 500W continuously for 90 to 264Vac input and 700W for 180
to 264Vac.
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage.

21

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.1

Highest efficiency 92.5% @ 230Vac

80Plus Gold
Active Power Factor Correction
RoHS compliant for all six substances

CPR-7211-1M1LF

Application for Server , Storage

Dimension346 x 76 x 40 mm ( D x W x H )
Total Max Power720W

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63Hz

Input current

11.0 - 3.0A

GENERAL SPECIFICATIONS
Hold-up time

15ms @ 75% Load

Efficiency

at least 92% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

59A

4.0A

120mVp-p

50mVp-p

Ripple & Noise

Note

22

1. The total output power can not exceed 720W continuously for 90 to 264Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High efficiency 94%

80Plus Platinum
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage

CPR-7411-1M1
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power740W

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63Hz

Input current

11.0 - 3.5A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

61.7A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 740W continuously for 90 to 264VAC input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

23

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2


80Plus Platinum(740W @ 85 - 264Vac)
80Plus Gold(850W @ 180 - 264Vac)
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage

CPR-7411-1M2
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power740W @ 85 - 264Vac


850W @ 180 - 264Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85- 264Vac

Input frequency

47 - 63 Hz

Input current

11.0 - 3.5A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

Platinum: 61.7A @ 100 - 140Vac


Gold: 70.8A @ 180 - 264Vac

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

24

1. The total output power can not exceed 850W continuously for 90 to 264Vac input.
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage.

UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

Highest efficiency 94%

80Plus Platinum
Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage
FCC class A (CPR-9211-1M1LF)

CPR-9211-1M1LF / 1M2LF
Dimension346 x 76 x 40 mm

FCC class B (CPR-9211-1M2LF)

(DxWxH)

Total Max Power920W

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63Hz

Input current

13.5 - 4.0A

GENERAL SPECIFICATIONS
Hold-up time

20ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

75A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 920W continuously for 90 to 264Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

25

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.1

High Power Density 20 W/in3

80Plus Gold

Highest efficiency 92.4%

Active Power Factor Correction


RoHS compliant for all six substances

CPR-1221-1M2LF
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power1000W @ 85 - 140Vac


1200W @ 180 - 264Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63 Hz

Input current

13.0 - 4.0A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 92% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

83A @ 85 - 140Vac
100A @ 180 - 264Vac

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

26

Application for Server , Storage , PowerBank

1. The total output power can not exceed 1005W continuously for 85 to 140Vac input, and 1205W
continuously for 180to 264 Vac input.
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut
down.

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 22 W/in3

80Plus Platinum

Highest efficiency 95%

Full Digital Power Supply


Active Power Factor Correction
RoHS compliant for all six substances
Application for Server , Storage , PowerBank

CPR-1221-5M1
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power1000W @ 90 -140Vac


1280W @ 180 - 264Vac

UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B, Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90- 264Vac

Input frequency

47 - 63Hz

Input current

13.0 - 5.5A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 95% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

83A @ 90 - 140Vac
106.7A @ 180 - 264Vac

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 1000W continuously for 90 to 140Vac input,and 1280W
continuously for 180 to 264 Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

27

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.1

High Power Density 21 W/in3

80Plus Gold

Highest efficiency 92%

Active Power Factor Correction


RoHS compliant for all six substances

CPR-1421-1M2LF
Dimension298 x 104 x 40 mm

(DxWxH)

Total Max Power1200W @ 100 - 140Vac


1400W @ 180 - 240Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63 Hz

Input current

15.0A max

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 92% @ 50% Load

MTBF

100,000 hours at 35 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

-5 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

100A @ 100 - 140Vac


117A @ 180 - 240Vac

6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

28

Application for Server, Storage, PowerBank

1. The total output power can not exceed 1200W continuously for 100 to 140Vac input, and 1400W
continuously for 180 to 264 Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage.

UL , cUL , TUV , CQC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.1

High Power Density 24 W/in3

80Plus Glod

Highest efficiency 92%

Active Power Factor Correction


FCC class A(CPR-1421-2M1LF)
FCC class B(CPR-1421-2M2LF)

CPR-1421-2M1LF / 2M2LF
Dimension346 x 76 x 40 mm

Application for Server , Storage , PowerBank

(DxWxH)

Total Max Power1105W @ 90 - 140Vac


1405W @ 180 - 264Vac

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

15.0 - 5.0A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 92% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

92A @ 100 - 140Vac


116A @ 180 - 264Vac

4.0 / 6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 1105W continuously for 90 to 140Vac input,and 1405W
continuously for 180 to 264 Vac input.
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down.

29

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 21 W/in3

80Plus Platinum

Highest efficiency 94.5%

Active Power Factor Correction


RoHS compliant for all six substances
Application for Server, Storage, PowerBank

CPR-1421-5M1
Dimension298 x 104 x 40 mm ( D x W x H )
Total Max Power1200W @ 90 - 140Vac
1400W @ 180 - 264Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

max 15.0A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 94.5% @ 50% Load

MTBF

100,000 hours at 35 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

100A @ 90 - 140Vac
117A @ 180 - 264Vac

6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

30

1. The total output power can not exceed 1200W continuously for 90 to 140Vac input, and 1400W
continuously for 180 to 264 Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage.

UL , cUL , TUV , CQC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

New!
FEATURES
N+1 Redundant

Support PMBus 1.2

High Power Density 26 W/in3

80Plus Titanium

Highest efficiency 96%

Full Digital Power Supply

EEPROM for FRU data

Cold Redundancy

No minimum load required

Active Power Factor Correction

CPR-1621-4M1
Dimension346 x 76 x 40 mm

Internal OR'ing

(DxWxH)

Total Max Power800W @ 100 - 140Vac


1600W @ 180 - 264Vac

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

11.0 - 7.0A

GENERAL SPECIFICATIONS
Hold-up time

11ms @ 75% Load

Efficiency

at least 96% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

16,500 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

66A @ 100 - 140Vac


133A @ 200 - 240Vac

4.0 / 6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The power & signal pins on the power supply connector (gold-finger area) must be gold plated to 30
micron- inches

31

AC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.1

High Power Density 27 W/in3

80Plus Platinum

Highest efficiency 94%

EEPROM for FRU data

Active Power Factor Correction

Air flow from AC inlet side to gold finger side (CPR-1621-1M4)


RoHS compliant for all six substances

CPR-1621-1M2 / 1M4
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power1000W @ 100 - 120Vac


1200W @ 120 - 140Vac
1620W @ 180 - 240Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

12.0 - 8.0A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

84A @ 100 - 120Vac


100A @ 120 - 140Vac
135A @ 180 - 240Vac

4.0 / 6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

32

Application for Server , Storage , PowerBank

1. The total output power can not exceed 1005W continuously for 100 to 120Vac input,1205W
continuously for 120 to 140Vac input and 1625W continuously for 180 to 264 Vac input.
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down.

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus1.2

High Power Density 29 W/in3

80Plus Platinum

Highest efficiency 94%

EEPROM for FRU data


Active Power Factor Correction
RoHS compliant for all six substances

CPR-1821-1M1
Dimension305 x 91 x 40 mm

Application for Server , Storage , PowerBank

(DxWxH)

Total Max Power1005W @ 100 - 120Vac


1205W @ 120 - 140Vac
1805W @ 180 - 240Vac

UL , cUL , TUV , BSMI , CQC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

85 - 264Vac

Input frequency

47 - 63Hz

Input current

15.0 - 5.0A

GENERAL SPECIFICATIONS
Hold-up time

17ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

84A @ 100 - 120Vac


100A @ 120 - 140Vac
150A @ 200 - 240Vac

4.0 / 6.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 1005W continuously for 100 to 120Vac input,1205W
continuously for 120 to 140VAC input and 1805W continuously for 180 to 264 Vac input
2. During load changes from minimum to maximum or maximum to minimum or no load the unit must
not shut down or damage

33

AC-DC Redundant Module

FEATURES
N+1 Redundant

Support PMBus 1.2

High Power Density 33.7 W/in3

80Plus Platinum

Support Cold Redundant

Full Digital Control

No Minimum load required

EEPROM for FRU data

Active Power Factor Correction

Application for HPC Server, PowerBank

CPR-2021-1M1
Dimension346 x 76 x 40 mm

Internal OR'ing

The air direction of PSU flows from output connector to AC inlet

(DxWxH)

Total Max Power1100W @ 100 - 120Vac


1400W @ 120 - 140Vac / 1800W @ 200 - 220Vac
1980W @ 220 - 230Vac / 2000W @ 230 - 240Vac
AC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

13.5 - 10.0A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

16,500 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

91.7A @ 100 - 120Vac


116.7A @ 120 - 140Vac / 150A @ 200 - 220Vac
165A @ 220 - 230Vac / 166.7A @ 230 - 240Vac

Ripple & Noise


Note

34

160mVp-p

The total output power cannot exceed 1100W continuously for input 100 to 120Vac
The total output power cannot exceed 1400W continuously for input 120 to 140Vac
The total output power cannot exceed 1800W continuously for input 200 to 220Vac
The total output power cannot exceed 1980W continuously for input 220 to 230Vac
The total output power cannot exceed 2000W continuously for input 230 to 240Vac

4.0A
(peak 6A)
90mVp-p

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC/DC-DC Dual-Input

www.compuware.com.tw

Green Server Power Supply

New!
FEATURES
Internal OR'ing

Support PMBus 1.2

80Plus Platinum

Digital Power Supply

High Power Density 17.5 W/in3


Active Power Factor Correction
EEPROM for FRU data

CDR-7011-1M1/1M2

Input AC capability (100 - 264Vac / 50 - 60Hz) or


wide input DC 180 - 300Vdc

Dimension322 x 54.5 x 40 mm ( D x W x H )
322 x 50 x 40 mm (CDR-7011-1M2)
UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

AC/DC-DC Dual-Input

Total Max Power700W @ 100 - 140Vac


750W @ 200 - 240Vac
INPUT SPECIFICATIONS
Input voltage

AC input 85 - 264Vac / DC input 180 - 300Vdc

Input frequency

47 - 63Hz

Input current

8.0 - 3.8A

GENERAL SPECIFICATIONS
Hold-up time

18 ms @ 75% Load

Efficiency

at least 94% @ 50% load

MTBF

1.100,000 hours at 100% load and 50 degree C


2.300,000 hours demonstrated at 100% load and 50 degree C.

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet (3,048 meters) Operating

Relative humidity

20% to 90% RH, Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

58A @ 100 - 140Vac


62A @ 200 - 240Vac

3.0A

120mVp-p

50mVp-p

Ripple & Noise

Drawing : CDR-7011-1M1

35

AC/DC-DC Dual-Input
New!
FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus1.2

High Power Density 21 W/in3

80Plus Platinum

Full Digital Power Supply

Cold Redundancy

EEPROM for FRU data

Active Power Factor Correction


Input AC capability (200 - 264Vac / 47 - 63Hz) or
wide DC input 180 - 300Vdc

CDR-1221-1M1
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power1280W


UL , cUL , TUV , CCC , BSMI , CB , FCC Class B , CISPR Class B , Meet CE , RoHS

AC/DC-DC Dual-Input

INPUT SPECIFICATIONS
Input voltage

AC input 200 - 264Vac / DC input 180 - 300Vdc

Input frequency

47 - 63Hz

Input current

8.0 - 6.0A

GENERAL SPECIFICATIONS
Hold-up time

18 ms @ 75% Load

Efficiency

at least 94% @ 50% load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet (3,048 meters) Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

(Input 200 to 264Vac


180 to 300Vdc)

(Input 200 to 264Vac


180 to 300Vdc)

120mVp-p

50mVp-p

Ripple & Noise

36

106.7A

4.0A

DC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus1.2

High Power Density 17 W/in3

92% typical at high line 50% Load


EEPROM for FRU data
RoHS compliant for all six substances

CDR-6611-1M1
Dimension322 x 50 x 40 mm

Application for Telecom Server

(DxWxH)

Total Max Power660W @ -42 to -72Vdc


UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , Meet CE , RoHS

DC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

-42 to -72Vdc

Input current

18.0 - 11.0A

GENERAL SPECIFICATIONS
Efficiency

92% typical at high line 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

5000 meters

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

55A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 660W continuously


2. The total peak output power can not exceed 700W at maximum duty cycle 5%
3. During load changes from minimum to maximum or maximum to minimum the unit must not shut down

37

DC-DC Redundant Module

FEATURES
Internal OR'ing

N+1 Redundant

Support I2C
High Power Density 17 W/in3
Highest efficiency 89%
RoHS compliant for all six substances

CDR-7111-1M1LF
Dimension346 x 76 x 40 mm

(DxWxH)

Total Max Power


710W @ -36 / 36Vdc to -75 / 75Vdc

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE, RoHS

DC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

-36 to -75Vdc

Input current

25.0 - 12.0A

GENERAL SPECIFICATIONS
Efficiency

89% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

10% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

59A

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 710W continuously for -36 to -75Vdc input
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down

38

Application for Telecom Server

DC-DC Redundant Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus1.1
High Power Density 17 W/in3
Highest efficiency 89%
RoHS compliant for all six substances

CDR-1021-1M1LF
Dimension346 x 76 x 40 mm

Application for Telecom Server

(DxWxH)

Total Max Power850W @ -36 to -40Vdc


1010W @ -41 to -76Vdc

UL , cUL , TUV , CCC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

DC-DC Redundant Module

INPUT SPECIFICATIONS
Input voltage

-36 to -76Vdc

Input current

30.0 - 17.0A

GENERAL SPECIFICATIONS
Efficiency

89% @ 50% Load

MTBF

150,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

70A @ -36 to -40Vdc


83A @ -41 to -76Vdc

4.0A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 1010W continuously for -41 to -76Vdc input
2. The total output power can not exceed 850W continuously for -36 to -40Vdc input
3. During load changes from minimum to maximum or maximum to minimum the unit must not shut down

39

Backup Battery
Server internal UPS Solutions
Improves stability, redundancy, and ease of maintenance
Hot-swappable and easy deployed
Increases overall data center power efficiency
Frees UPS space to increase server density deployment
More cost-effective than expensive Data Center UPS
Fits most Compuware Power Supply

Backup Battery
40

Backup Battery

CPR-2011-1M1
DC 200W - ( Li-Ion Battery)

Green Server Power Supply

CPR-1021-4M1
Total Output Power

DC 1000W - ( Li-Ion Battery)

Discharging time

5 minutes at load 200W


8 minutes at load 150W
15 minutes at load <=100W

Discharging time

1 minute at load 1200W


2.5 minutes at load 1000W
3 minutes at 600W< load <=800W
5 minutes at 300W<load <=500
10 minutes at load 300W

Form Factor

1U

Form Factor

1U

Recharge Period

5 hours

Recharge Period

5 hours

Dimension

220 x 54.5 x40 mm ( D x W x H )

Dimension

346 X 76 X 40 mm ( D x W x H )

Battery Capacity

40Whr

Battery Capacity

97Whr

Redundant

Yes

Redundant

Yes

I2C Remote
Monitotring

FRU / Smart battery I2C

I2C Remote
Monitotring

FRU / Smart battery I2C

12V

16.7A

12V

83.3A

5Vsb

2.0A

5Vsb

4.0A

Efficiency

Protection Circuits

Online mode power


consumption less than 2W
OCP, OVP, OTP,
Short Circuit Protection

Efficiency

Protection Circuits

Backup Battery

Total Output Power

www.compuware.com.tw

Online mode power


consumption less than 2W
OCP, OVP, OTP,
Short Circuit Protection

Temperature

From 5 to 45 degrees Celsius

Temperature

From 10 to 45 degrees Celsius

Humidity

20% to 90% RH non-condensing

Humidity

20% to 90% RH non-condensing

Altitude

10,000 feet

Altitude

10,000 feet

41

CRPS
New!
FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 33 W/in3

80Plus Titanium

Digital Power Supply

Cold Redundancy

Smart ride through

Black Box Recorder

Automatic firmware update

Intel standardizing CRPS form factor


Active Power Factor Correction

CPR-1021-6M1
Dimension185 x 73 x 40 mm

Closed loop system protection (CLST)

(DxWxH)

Total Max Power1000W


UL , cUL , TUV , CCC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

CRPS

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

GENERAL SPECIFICATIONS
Hold-up time

11 ms @ 70% Load

Efficiency

at least 96% @ 50% Load

MTBF

200,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree Coperating

Altitude

3050 meters Operating

Relative humidity

To 85% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+12Vsb

Regulation

5%

5%

Max Load

66.7A @ 100 - 127Vac


83A @ 200 - 240Vac

1.2A

120mVp-p

120mVp-p

Ripple & Noise

42

CRPS

www.compuware.com.tw

Green Server Power Supply

New!
FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 42.8 W/in3

80Plus Platinum
Full Digital Power Supply
Cold Redundancy
Intel standardizing CRPS form factor

CPR-1821-4M1
Dimension265 x 73 x 40 mm

Active Power Factor Correction

(DxWxH)

Total Max Power1000W @ 90 - 132Vac


1820W @ 200 - 264Vac

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

CRPS

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

12.5 - 9.5A

GENERAL SPECIFICATIONS
Hold-up time

11 ms @ 70% Load

Efficiency

at least 94% @ 50% Load

MTBF

250,000 hours at 75% load

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

3050 meters Operating

Relative humidity

To 80% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+12Vsb

Regulation

5%

5%

Max Load

83A
150A

3.5A

120mVp-p

120mVp-p

Ripple & Noise

43

CRPS
New!
FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 47.5 W/in3

80Plus Platinum

Full Digital Power Supply

Intel standardizing CRPS form factor


Active Power Factor Correction

CPR-2021-2M1

Cold Redundancy

Dimension265 x 73 x 40 mm (D x W x H )
Total Max Power
1000W @ 90 - 132Vac / 1800W @ 200 - 220Vac
1980W @ 220 - 230Vac / 2000W @ 230 - 264Vac
CRPS

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

12.5 - 9.5A

GENERAL SPECIFICATIONS
Hold-up time

11 ms @ 70% Load

Efficiency

at least 94% @ 50% Load

MTBF

250,000 hours at 75% load

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

3050 meters Operating

Relative humidity

To 80% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+12Vsb

Regulation

5%

5%

Max Load

83A @ 90 - 132Vac
166.7A @ 200 - 264Vac

3.5A

120mVp-p

120mVp-p

Ripple & Noise

44

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Blade Server Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

Support PMBus 1.2

High Power Density 13.7 W/in3

80Plus Platinum

Digital Power Supply

Black Box
Active Power Factor Correction
EEPROM for FRU data

CPR-1627-2M1
Dimension241.3 x 106.6 x 82 mm (D x W x H )
Total Max Power1600W

UL , cUL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS

Blade Server Module

INPUT SPECIFICATIONS
Input voltage

90 - 264Vac

Input frequency

47 - 63Hz

Input current

7.1 - 5.5A

GENERAL SPECIFICATIONS
Hold-up time

12 ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

250,000 hours at 75% load

ENVIRONMENTAL SPECIFICATIONS
Temperature

0 to 50 degree C Operating

Altitude

5,000 meters Operating

Relative humidity

To 80% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+12Vsb

Regulation

5%

5%

Max Load

133A @ 200 - 264Vac

3.0A @ 100 - 264Vac

120mVp-p

120mVp-p

Ripple & Noise


Note

1. The total output power cant exceed 1200W continuously for 100 to 120 Vac input.
2. The total output power cant exceed 1400W continuously for 120 to 140 Vac input.
3. The total output power cant exceed 1600W continuously for 200 to 264 Vac input.
4. During load changes from minimum to maximum or maximum to minimum the unit mustnot shut down.
5. +12Vsb will be designed to meet 3A load and will be tested with 3A load atproduction line.
6. Model label (I/O label) will print 2A rating only (safety test 2A only).

45

Blade Server Module

FEATURES
Internal OR'ing

N+1 Redundant

EEPROM for FRU data


High efficiency 90%+
Active Power Factor Correction (APFC) , PF > 0.95
RoHS compliant for all six substances

CPR-1627-1M1LF
Dimension241.3 x 216 x 100 mm

(DxWxH)

Total Max Power1200W @ 90 - 140Vac


1620W @ 180 - 264Vac
Blade Server Module

INPUT SPECIFICATIONS
Input voltage

90 - 140Vac / 180 - 264Vac

Input frequency

47 - 63Hz

Input current

10.5 - 14.7A / 8.3 - 11.0A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 90%+ @ 50% Load

MTBF

100,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

10 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

20% to 90% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

100A @ 90 - 140Vac
132A @ 180 - 264Vac

16A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 1200W / 1620W for low / high line AC input respectively
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
3. The outputs can exceed regulation limits (limited to UV/OV criteria) for steps greater than 85 amps

46

Application for Blade Server

UL , cUL , TUV , CQC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS , CSA , BSMI

Blade Server Module

www.compuware.com.tw

Green Server Power Supply

FEATURES
Internal OR'ing

N+1 Redundant

80Plus Platinum

EEPROM for FRU data

Highest efficiency 94.07% @ 50% Loading


Active Power Factor Correction (APFC) , PF > 0.95
RoHS compliant for all six substances

CPR-2527-1M2LF
Dimension257.3 x 216 x 100 mm

CPR-2527-1M1LF Application for Blade Server

(DxWxH)

Total Max Power2500W

UL , cUL , TUV , CQC , CB , FCC Class A , CISPR Class A , Meet CE , RoHS , CSA , BSMI

Blade Server Module

INPUT SPECIFICATIONS
Input voltage

180 - 264Vac

Input frequency

47 - 63Hz

Input current

11.0 - 15.0A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94 % @ 50% Load

MTBF

100,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

-5 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

5% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

208A

16A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 2500W for AC input respectively
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
3. The outputs can exceed regulation limits (limited to UV/OV criteria) for steps greater than 85 amps

47

Blade Server Module

FEATURES
Internal OR'ing

N+1 Redundant

80Plus Platinum

EEPROM for FRU data

Highest efficiency at least 94% @ 50% Loading


Active Power Factor Correction (APFC) , PF > 0.95
RoHS compliant for all six substances
Application for Blade Server

CPR-3027-1M1
Dimension257.3 x 216 x 100 mm

(DxWxH)

Total Max Power3000W

UL , TUV , CQC , BSMI , CB , FCC Class A , CISPR Class A , Meet CE , RoHS , CSA

Blade Server Module

INPUT SPECIFICATIONS
Input voltage

180 - 264Vac

Input frequency

47 - 63Hz

Input current

17.5 - 15.0A

GENERAL SPECIFICATIONS
Hold-up time

18ms @ 75% Load

Efficiency

at least 94% @ 50% Load

MTBF

100,000 hours at 25 degree C

ENVIRONMENTAL SPECIFICATIONS
Temperature

-5 to 50 degree C Operating

Altitude

10,000 feet Operating

Relative humidity

5% to 95% RH Operating

OUTPUT SPECIFICATIONS
Voltage

+12V

+5Vsb

Regulation

5%

5%

Max Load

250A

16A

120mVp-p

50mVp-p

Ripple & Noise


Note

1. The total output power can not exceed 3000W for high line AC input continuously
2. During load changes from minimum to maximum or maximum to minimum the unit must not shut down
3. The outputs can exceed regulation limits (limited to UV/OV criteria) for steps greater than 85 amps

48

Green Innovation creates the future

Headquarters, Taipei, Taiwan


2352325 ()
5F, No.232, Liancheng Rd., Zhonghe District, New Taipei City 235,Taiwan R.O.C.
TEL+ 886-2-8226-3936
FAX+ 886-2-8226-3937
E-mail: sales@compuware.com.tw

Taiwan Factory, Bade


3063
3F., No.306, Changan St., Bade City, Taoyuan County 334, Taiwan R.O.C.
TEL+ 886-2-8226-3936
FAX+ 886-2-8226-3937

China Branch, Beijing


3173-801
Jinquan Age 3-801 Datunli No.317, Chaoyang District, Beijing, P.R.China
TEL+ 86-10-82427375
FAX+ 86-10-82427378

China Factory, Shenzhen


120692721
No.12069, Shennan Rd.,Nanshan District, Shenzhen City , P.R.China
TEL+ 86-755-83458542
FAX+ 86-755-83458617

, , US Branch, Fremont
48293 Fremont Blvd., Fremont, CA 94538
E-mailsupport@compuware-us.com