Fig7
SEG-Y Data Input Window > Select Data Media Storage as Disk > Select Analyze tab
(Check Data Attribute, Domain, update from template etc)
Fig8
Fig9
In SEG-Y Analyzer Window select the Disk file name (File > Select > Select the .sgy file).
Select start bottom to start the Analyze ..........Remember It will take some time
Note: The data will shown in Disk File name area , then push the start bottom , it will take automatically the standard
default segy template in Template name area /other wise select the template name from interactive SEGY analyzer
window ( Interactive SEGY Analyzer window > Template > Select> Standard SEGY) and the start the Analyze Process
Fig10
Fig:11
Fig:12
Fig:13
The Analyzing Job is complete now. Now to check the template whether it is correct or any scaling factor is required
for CDPX and CDPY value.
Fig14
Go to the Interactive SEGY Analyzer window and Show EBCIDIC Text header like Iline, X line, Shot Point, CDP
X Coordinate, CDO Y Coordinate etc.
Compare the EBCIDIC text header and BINARY trace heard of selected data whether binary trace header are
correct or any changes is required in In-line, X-line, Shot Point, CDP X and CDP Y Coordinate Position. The
value of CDPX and CDPY may check carefully whether any scaling factor is required or not.
To shoe the Binary Trace Header :: Interactive SEGY Analyzer > Trace > Header view
Fig15
Fig16
Now Check the Trace header information ( Mainly Shot point, X Cord, Y Cord, #D Line and 3D Trace :: marked in blue
portion of Trace header view ) with EBCDIC Header Information (Which information we already got by clicking
Interactive SEGY Analyzer tab).
Fig:15
Fig16
Comparison Result:
Byte Information of Inline, X Line, CDPX and CDP Y indicated in EBCIDIC Text header is not match with Trace
header view and also digit of CDPX and CDPY is also not correct.
Note the header information in trace header view is showing the information from automatic selected
Standard_SEGY format.So the template format is required modification according the original EBCIDIC data
information.
SEGY Analyzer browse > Edit template :: This template is the default template named as Standard_SEGY
intially for which wrong trace header fig 16 was shown , therefore modification and also save after this is
required for this template. Later using this modified template we will again analyze the input seismic .sgy
data to check whether the prvious problem byte location value of x y is showing correctly after scaling
factor. If it is shows ok then it will (this modified saved template will be used during our input data loading.
the standard SEGY template will open
SeG y Analyzer window > Browse / Edit template
After save ----plz check whether template is change and correct binary header is given for this again the data analyze
and check the x y factor, if it is ok, then save, your template is rready to use for data load
Save the format ................ and this format is apply in template name ------------- and again analyze and see the
differenvce