You are on page 1of 22

Transmittal

Date:

July 22, 2013

To:

Steve Busen, LEED AP


Skanska
26100 American Drive
Suite 200
Southfield, Michigan 48034-2367

From:

Shannon Shackelford

Project:

Cardiovascular Institute and Harper-Hutzel Specialty Center


Detroit Medical Center,
Detroit, Michigan

Project No:

2011-10001-000

Owner Project No:


Sent Via:

Electronic E-Builder Site

Distribution:

Jones Lange LaSalle


Andrea Burg

For your:

Use/Records

Jenkins
Construction, Inc.
James Robinson

Enclosed Please Find:


Quantity

Description

Product Data/Shop Drawings APPROVED AS NOTED


1

Cubicles - Curtain Track

Message:

J/S Reference No. 823

Harley Ellis Devereaux Log No. 102123-1A


Received by:

Date:

If checked, please return a signed copy to Harley Ellis Devereaux.

If enclosures are not as noted, please inform us immediately.

Transmittal.doc (Revised 01-08)

\\DET-HAR-FILE01\STUDIO PROJECTS\HEALTHCARE\D M C HEALTH CARE CENTERS\2011-10001-000 CARDIO VAS INST\CONST\SHOPDRAW\SUBMITTAL LABELS AND TRANS\TRANSMITTA

SUBMITTAL LABEL

PROJECT NO:

2011-10001-000

DATE

Cardiovascular Institute and Harper-Hutzel


Specialty Center
Detroit Medical Center
Detroit, Michigan
July 9, 2013

CONTRACTOR/SUPPLIER

Jenkins/Skanska

DESCRIPTION

Product Data/Shop Drawing


Cubicles - Curtain Track
J/S Reference No. 0823
102123

PROJECT

SPECIFICATION NO.

COMMENTS
GENERAL REVIEW NOTES
1. Coordinate work with related trades.
2. See individual sheets for additional review comments.
3. Lengths and quantities not verified, provided as
generally indicated on the drawings and conditions
constructed in the field.

Kevin Doyle

7/18/13

2011-10001-000

102123-1A


  




   !

 !

"#$#%&'(


  ('''&'"

!)!!!
*+!

&$%(

!, 

+* 
-1!


&&&'

'&%'%(

&

* !
3

 

+
 
-


 .
/,
01.


2
 
,,

!
 !

"#%%#%&'(

!!!
4

*

-1
*+!




-1!
 
* !


 

 



 !" #

#$

%%
 
&'()%!(
*
+(),, -%%
.+(),, - 65

,!
!  !1 !

% ! $!/
% ! $!3

 *,5
*!

+* !
)
,,

* !
5



   


)-$

/



!%%

 &'()%0

5,!

% !,%%%% 8 
,%



% !,%%%% 7 #9
,%
 
*!

 !*
!, 

 !*
 

12314,15 1 *  

56
  
/77 

12314,15 1 *  7


 #9

56
  
/77 

,!

 !

!*-

Jenkins Skanska Joint Venture

Isiah White

7/8/13
DMC Cardiovascular Institute

Harley Ellis Devereaux


0001-102123-0
102123

1 !

0823

1!
 !
8 
+0:):% !

-1
 

89


C/S Cubicle Curtains

Construction Specialties, Inc.


107 Johnson Blvd.
Del Rio, TX 78840
Sales (908) 325-4900
Customer Service: (908) 849 4750
Customer Service Fax: (908) 849-4399
www.c/sgroup.com

SHOP DRAWING TRANSMITTAL


FOR APPROVAL ONLY - FABRICATION PENDING RELEASE
Date: 07 /03 / 2013
PONTIAC CEILING & PARTITION
715 AUBURN RD
PONTIAC, MI 48342
ATTN: JEFFREY M. STONE
RE: DMC CARDIOVASCULAR INSTITUTE
C/S ORDER NO: 998190
YOUR PO: SQ130006

Dear Customer,
Thank you for purchasing C/S products. My name is Peter Lopez, with Construction Specialties Cubicle
Curtains. Here at C/S we take great pride in our work. If you have any questions regarding these drawings,
please contact me at (908) 849-4750 or at Email pelopez@c-sgroup.com.
The enclosed shop drawings represent our interpretation of your order based on data in our possession and our
standards. A field check is recommended. Our responsibility for job fit is limited to fabrication from these shop
drawings when released by you as approved or corrected.
A shipping schedule can be established only upon our receipt of one set of our shop drawings properly released
and mutually acceptable. This release MUST INCLUDE YOUR COLOR SELECTION (IF APPLICABLE)
AND A SIGNATURE. The average fabrication lead-time is two to three weeks on track orders and three to
four weeks on curtains, depending on fabric availability.
Best Regards,
Peter Lopez.
Drafting
C/S Cubicle Curtains Company

* Note: To help with faster lead times please include the following:
1. Ship to address.
2. Fabric and Color selected.
3. Date when material is required.
** Fabric will be ordered upon receipt of approved shop drawings.

Re: SUBMITTALS
Please find the following items enclosed:

1 SHOP DRAWING COPIE

2 TRACK SAMPLES WITH ACCESSORIES:


SATIN ANODIZED
Not included in this submittal.

2 IV TRACK SAMPLES:
SATIN ANODIZED

If you should have any questions please contact me.


Thank you,
Peter Lopez.
C/S Cubicle Curtains.
Phone: (908) 849-4750
Fax: (908) 849-4399
Email: pelopez@c-sgroup.com

Construction Specialties, Inc.


107 Johnson Blvd.
Del Rio, TX 78840
Sales (908) 325-4900
Customer Service: (908) 849-4750
Customer Service Fax: (908) 849-4399

Warranty
Our Cubicle Track and IV Track are guaranteed against defects for one year after ship
date provided it is installed correctly and according to our installation instructions. We
shall not, under any circumstances be liable for direct or consequential damages
resulting from the use of our product that has been installed in any other way than by
our instructions.
MANUFACTURERS

MANUFACTURERS AND DISTRIBUTORS OF HOSPITAL CUBICLE TRACK, CARRIERS AND CUBICLE CURTAINS

Construction Specialties, Inc.


107 Johnson Blvd.
Del Rio, TX 78840
Sales (908) 325-4900
Customer Service: (908) 849-4750
Customer Service Fax: (908) 849-4399

Maintenance
Because of the simplicity of the cubicle track system, there are no operating or
maintenance manuals. The All-Nylon wheels and axles are designed to perform flawlessly.
No lubrication is necessary and short of an occasional dusting, there is nothing else
required to be done.

MANUFACTURERS AND DISTRIBUTORS OF HOSPITAL CUBICLE TRACK, CARRIERS AND CUBICLE CURTAINS

SURFACE MOUNTED
CUBICLE CURTAIN TRACK
The C/S Cubicle Curtain track is Dual Channel, extruded aluminum track
made from aluminum alloy in a anodized or white baked enamel. Track
dimensions are 1 3/8" x 3/4" deep (see below) with a minimum wall.

SMCCT #6062

* Drawing not to
scale
1062N CARRIER

Carrier Stop #162

Carrier Gate #262

Construction Specialties, Inc.


107 Johnson Blvd.
Del Rio, TX 78840
Sales (908) 325-4900
Customer Service: (908) 849-4750
Customer Service Fax: (908) 849-4399

Splice #862

Specification for Surface Mounted Cubicle Track

PART 2 PRODUCTS
2.01

ACCEPTABLE MANUFACTURERS
A. General: Cubicle Track system shall be complete as specified in this section and manufactured by
Cubicle Curtains, Cranford, NJ.
B. Substitutions: Other manufacturers are acceptable for evaluation only after compliance with Section
01630.

2.02

CUBICLE TRACK SYSTEM


A. Cubicle Track: Surface-mounted tracks of heavy extruded aluminum alloy 6063 T5, 1-3/8" x 3/4",
slotted to receive roller carriers, compete with accessories and components required for complete
and secure installations including splices, end caps and corner bends.
1.
2.

Corner Bends: Shall have a 12" radius minimum.


Finish: Satin Anodized.

B. Carriers: Virgin nylon axle with nylon wheels, complete with nickel-plated brass bead-chain and
hook assembly.

C/S G E N E R A L C U B I C L E

Construction Specialties, Inc.


107 Johnson Blvd.
Del Rio, TX 78840
Sales (908) 325-4
4900
Customer Service: (908) 849 4750
Customer Service Fax: (908) 849-4
4399

INSTALLATION INSTRUCTIONS FOR CEILING-MOUNTED CUBICLE TRACK


Attached is a copy of our Tally Sheet, which lists all items required for individual rooms. The totals shown on this list should
be used to check items received in shipment. Reports of shortages will not be accepted if made after (5) days after shipment has been received.
Large Bends (8'x8') will be furnished only where a project is large enough to offset the cost of crafting these bends. Where
this is not permissible, Small Bends (2'x2') will be furnished with Splices and proper lengths of track - to be joined to the
Small Bends.
Measurements of Large Bends is approximately 8' 2 " x 8' 2 ". These will be shipped this way, to be cut on the job. For
proper installation, follow "Shop Drawing" for lay-out, if parts shipped were based on this.
1.

Mark ceiling lightly where track is to be installed. Drill track at proper intervals. Start at the
center point of radius, and drill every 3' 0" on both directions. NOTE: Drill must be in perfect center
of track! When drilling ends of track, affix stops and gates and drill through these.

2.

Prop track against ceiling with boards. Mark ceiling through drilled holes. Remove
track and drill through ceiling. (Size of drill to be determined by type of fasteners
you are using.) NOTE: If track is to be mounted against wood backings, then keep
tracking against ceiling, drill "guide hole" through ceiling, and then use proper
length of Wood Screws for a strong hold.

3.

Head of fasteners should be pan-head - not to exceed Size No. 8

4.

Carrier Stop used at Terminus of track, with Carrier Gate used at Curtain Stacking
Point. Carriers need not be installed at this time; however, if they are, remove Gate
From fitting and insert proper amount of Carriers required for the curtain to be used.
Standard spacing is every 6" - which is more than ample to assure a strong installation. To figure
proper amount of Carriers, use this guide: Size of Curtains - Double - Plus One.
Example: 16' 0" Curtain - i.e. 16 plus 16 - plus one - total 33.

5.

Where track has to be spliced, pay particular attention to ends being joined. The
Splice being furnished has been designed in such a way to assure this; however, burrs cause the
Carriers to bind. Clean ends thoroughly, file burrs off, even forma small chamfer as a safeguard, and slip
both ends into Splice. Put fastener on both ends of track!

Suspended Installation
Basic instruction above also applies for a Suspended Installation, except the following:
1.

Standard Suspension height from floor is 7' 3". Install Wall Sockets per dimensions on Shop
Drawing at this height. Prop Large Bend, cut to proper size, with ends in Wall sockets. If an additional
cubical is to be attached, fit "Radius Tie Assembly" at radius of first cubical.

2.

Track Socket can be fitted to any of the four (4) points in the Radius Tie Assembly. With the
track at proper length and attach to both sockets by self-tapping screws furnished.

3.

Use additional risers if shown on Shop Drawing.

4.

Carriers can be inserted into track by removing "Gate" which lies in Wall Sockets. Replace
Gate after proper amount of Carriers has been inserted.

5.

Ceiling Risers must be used wherever a Splicer is used.

Specification for Surface Mounted IV Track


PART 2 PRODUCTS
2.01

ACCEPTABLE MANUFACTURERS

A. General: IV Track system shall be complete as specified in this section and manufactured by
Cubicle Curtains, Cranford, NJ.
B. Substitutions: Other manufacturers are acceptable for evaluation only after compliance with
Section 01630.
2.02

IV TRACK SYSTEM

A. I.V. Tracks: Cubicle Curtains I.V. track model #17000. Surface-mounted tracks of heavy
extruded aluminum alloy 6063-T5, 1 " x ", slotted to receive twist lock I.V. Carrier,
compete with accessories and components required for complete and secure installations
including splicers, end caps and corner bends.
1. Finish: Satin Anodized.
B. Carriers: Cubicle Curtains 17500 Twist-Lock I.V. Carrier, Carrier mechanism shall be
designed to lock against surface of reinforcing I.V. Track.
1. Provide one carrier per unit of I.V. Track, or as needed.

Surface Mounted I.V Tack


The C/S General Cubicle I.V Track is dual channel, extruded aluminum track
Made from aluminum alloy in baked white enamel.

Aluminum I.V Carrier Stop # 162(W)


17500 TWIST LOCK
I.V. CARRIER

Aluminum I.V Carrier Gate # 262(W)

I.V Splice # 862(W)

17500 Twist Lock I.V. Carrier


This I.V. carriers body and wheels are manufactured from one-piece
molded Celcon. The shaft and safety hook are nickel chrome plated steel.
The carrier locks by twisting the safety hook turn.

49 Meeker Avenue
Cranford, NJ 07016
Tel: (908) 849-4749
Fax: (908) 849-4399

DELUXE 5 BOTTLE I.V. PENDANT


MODEL# 17150
Fabricated of polished stainless steel this unit has a " diameter
tubing for the main shaft, 3/8" diameter for the inner shaft, and four
folding " diameter spiral safety arms plus one additional hook in the
bottom as the fifth holder.

30

This proposal is most similar to the project


specified surface mounted details for
Cubicle Curtain and IV Track, for lay-in
ceiling and gyp bd ceiling. See details 1 &
2 on Sht A5-51 and abide.

Not applicable to project

Confirm assigned
scope. Only curtains
are not construction
scope responsibility.

Yes

P/R 1 ISO

41030A

You might also like