You are on page 1of 2412

HyperWorks 13.

0
OptiStruct Reference Guide

HyperWorks is a division of Altair

altairhyperworks.com

Altair Engineering Support Contact Information


Web site

www.altairhyperworks.com

Location

Telephone

e-mail

Australia

64.9.413.7981

anzsupport@altair.com

Brazil

55.11.3884.0414

br_support@altair.com

Canada

416.447.6463

support@altairengineering.ca

China

86.400.619.6186

support@altair.com.cn

France

33.1.4133.0992

francesupport@altair.com

Germany

49.7031.6208.22

hwsupport@altair.de

India

91.80. 6629.4500
1.800.425.0234 (toll free)

support@india.altair.com

Italy

39.800.905.595

support@altairengineering.it

Japan

81.3.5396.2881

support@altairjp.co.jp

Korea

82.70.4050.9200

support@altair.co.kr

Mexico

55.56.58.68.08

mx-support@altair.com

New Zealand

64.9.413.7981

anzsupport@altair.com

North America

248.614.2425

hwsupport@altair.com

Scandinavia

46.46.460.2828

support@altair.se

United Kingdom

01926.468.600

support@uk.altair.com

In addition, the following countries have resellers for Altair Engineering: Colombia, Czech Republic, Ecuador, Israel, Russia,
Netherlands, Turkey, Poland, Singapore, Vietnam, Indonesia
Official offices with resellers: Canada, China, France, Germany, India, Malaysia, Italy, Japan, Korea, Spain, Taiwan, United
Kingdom, USA
Copyright Altair Engineering Inc. All Rights Reserved for:
HyperMesh 1990-2014; HyperCrash 2001-2014; OptiStruct 1996-2014; RADIOSS1986-2014; HyperView1999-2014;
HyperView Player 2001-2014; HyperStudy 1999-2014; HyperGraph1995-2014; MotionView 1993-2014; MotionSolve 20022014; HyperForm 1998-2014; HyperXtrude 1999-2014; Process Manager 2003-2014; Templex 1990-2014; TextView
1996-2014; MediaView 1999-2014; TableView 2013-2014; BatchMesher 2003-2014; HyperMath 2007-2014;
Manufacturing Solutions 2005-2014; HyperWeld 2009-2014; HyperMold 2009-2014; solidThinking 1993-2014; solidThinking
Inspire 2009-2014; solidThinking Evolve 1993-2014; Durability Director 2009-2014; Suspension Director 2009-2014;
AcuSolve 1997-2014; AcuConsole 2006-2014; SimLab2004-2014 and Virtual Wind Tunnel 2012-2014.
In addition to HyperWorks trademarks noted above, Display Manager, Simulation Manager, Compute Manager, PBS,
PBSWorks, PBS GridWorks, PBS Professional, PBS Analytics, PBS Desktop, PBS Portal, PBS Application Services,
e-BioChem, e-Compute and e-Render are trademarks of ALTAIR ENGINEERING INC.
Altair trademarks are protected under U.S. and international laws and treaties. Copyright 1994-2014. Additionally, Altair software
is protected under patent #6,859,792 and other patents pending. All other marks are the property of their respective owners.
ALTAIR ENGINEERING INC. Proprietary and Confidential. Contains Trade Secret Information. Not for use or disclosure outside of
ALTAIR and its licensed clients. Information contained inHyperWorks shall not be decompiled, disassembled, or unlocked,
reverse translated, reverse engineered, or publicly displayed or publicly performed in any manner. Usage of the software is only as
explicitly permitted in the end user software license agreement.
Copyright notice does not imply publication

OptiStruct 13.0 Reference Guide

Reference
...........................................................................................................................................
Guide
1
Input
Data
...............................................................................................................................................
2
The Bulk
Data
Input
File
................................................................................................................................... 3
Guidelines
for I/O Options and Subcase Information Entries
...................................................................................................................................
7
Guidelines
for Bulk Data Entries
...................................................................................................................................
9
Solution
Sequences
Data
Selectors
(Table)
................................................................................................................................... 14
Summary
of Defaults for I/O Options
...................................................................................................................................
15
I/O Options
Section
................................................................................................................................... 22
Subcase
Information Section
...................................................................................................................................
233
Bulk...................................................................................................................................
Data Section
318
Element
Quality Check
...................................................................................................................................
2160
Material
Property Check
...................................................................................................................................
2189
Output Data
...............................................................................................................................................
2197
List
of Files Created by OptiStruct (Alphabetical)
...................................................................................................................................
2200
Results
Output by OptiStruct
...................................................................................................................................
2346
Legacy
Data
............................................................................................................................................... 2378
Previous
(OS3.5) Input Format
...................................................................................................................................
2379
Setting Up Decks in OptiStruct 5.0 with OptiStruct 3.5 Objectives and
Constraints
................................................................................................................................... 2384
Previously
Supported Input
...................................................................................................................................
2388

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Reference Guide
Input Data
Output Data
Legacy Data

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Input Data
I/O Options Section
Subcase Information Section
Bulk Data Section
Element Quality Check
Material Property Check

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

The Bulk Data Input File


The input file in OptiStruct is composed of three distinct sections:
The I/O Options Section
The Subcase Information Section
The Bulk Data Section
The I/O Options Section controls the overall running of the analysis or optimization. It
controls the type, format, and frequency of the output, the type of run (check, analysis,
super element generation, optimization or optimization restart), and the location and names of
input, output, and scratch files.
The Subcase Information Section contains information for specific subcases. It identifies
which loads and boundary conditions are to be used in a subcase. It can control output type
and frequency, and may contain objective and constraint information for optimization
problems. For more information on solution sequences, see the table included on the Solution
Sequences page of the online help.
The Bulk Data Section contains all finite element data for the finite element model, such as
grids, elements, properties, materials, loads and boundary conditions, and coordinates
systems. For optimization, it contains the design variables, responses, and constraint
definitions. The bulk data section begins with the BEGIN BULK statement.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

These sections can be arranged in either a one-file setup or a multi-file setup (there is also an
obsolete two-file setup that is no longer recommended).

One-File Setup
In a one-file setup, all three data sections are included in one file. The bulk data section
must be the last section. It is recommended that the extension .fem be used for this file.

Multi-File Setup
A multi-file setup is facilitated through the use of INCLUDE statements. This option enables
you to include information from other files without cutting and pasting. INCLUDE statements
may be placed in any section of the one or two-file setup, but must include information
appropriate to the section.
The following example shows how an additional subcase can be added to the Subcase
Information section.
input.fem file

sub2.inc

$
Subcase 1
SPC = 1
Load = 2
$
INCLUDE sub2.inc
$
BEGIN BULK
$

Subcase 2
SPC = 1
Load = 3

The solver reads all files and positions the lines of the included file at the location of the
INCLUDE statement in the input.fem file. An echo of the input.fem file as read by
OptiStruct would be:
$
Subcase 1
SPC = 1
Load = 2
$
Subcase 2
SPC = 1
Load = 3
$
BEGIN BULK
$

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Two-File Setup
This setup is obsolete; the one-file or multiple-file setups are recommended.
The two-file setup separates the control data (I/O Options section and Subcase Information
section) from the model data (Bulk Data section). If the input file does not contain a BEGIN
BULK statement, the solver attempts to read the model data from another file:
If the INFILE card is present in the I/O Options section, the argument given on this
card is the name of the file that contains the model data.
If the INFILE card is not present in the I/O Options section, and the input file does not
have the extension .fem, the name of the file containing the model data will be
constructed from the input file by replacing the extension with .fem.
The two-file setup allows you to perform runs using multiple control data files and a single
model file and vice versa. It is recommended that the .parm extension be used for control
data files and the .fem extension be used for model data files.
Notes: The format of the input sections in OptiStruct
are similar to those of the Nastran format.
File names specified on INCLUDE and other cards
(RESTART, EIGVNAME, LOADLIB, OUTFILE, TMPDIR,
ASSIGN) can be arbitrary file names with optional
paths appropriate to the operating system (Windows
or UNIX). They may be enclosed in quotes (double or
single quotes can be used), and either forward slash
(/) or back slash (\) characters can be used to
separate parts of the pathname.
The solver uses the following rules to locate a file name
on the INCLUDE cards:
When the argument contains the absolute path
of the file (if it starts with "/" on UNIX or a drive
letter, such as "D:", on Windows, for example),
the file at the given location is used.
When only the file name is given (without the path),
the file has to be located in the same directory as
the file containing the INCLUDE statement.
When the argument contains a relative path
(../filename or sub/filename, for example), it
is located in the directory relative to the file
containing the INCLUDE statement and is NOT
relative to the directory in which the solver was
executed, or to the directory where the main file
is located.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Compressed input files


An input file and referenced included files can be optionally compressed using gzip
compression. A compressed file has to have the extension .gz appended to the file name.
Valid example file names are: input.fem.gz, input.gz, and input.dat.gz. Compressed files
can be mixed with plain ASCII files. The INCLUDE card does not have to be modified when a
file is compressed. For example, if the card INCLUDE infile.dat were present, the reader
would search for infile.dat and continue on to search for the compressed file,
infile.dat.gz, if not found. Other input files (such as RESTART, ASSIGN) cannot be
compressed.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Guidelines for I/O Options and Subcase Information


Entries
The following guidelines apply to all entries in the I/O Options and Subcase Information
sections:
All input cards are limited to 80 characters per line; all characters after the 80th are
skipped. SYSSETTING,CARDLENGTH may be used to change the number of characters
allowed in each line.
Cards which require a file name (OUTFILE, RESTART, INCLUDE, LOADLIB, TMPDIR,
EIGVNAME, ASSIGN) can contain up to 200 characters in a single line. Alternatively,
the file name may be continued in several lines if it is enclosed in quotes (" or ). When
combining continuation lines, all trailing and leading blanks in each line are omitted.
Other blanks, including all blanks between the quote and file name, are considered as
part of the file name.
File names can contain an absolute or relative path. Forward slash (/) or back slash
(\) characters can be used to separate parts of a path name. Absolute paths are
discouraged since they prevent moving files from one location to another, and may
cause unexpected failures, as in PBS or a similar batch environment.
Windows style file names, starting with the drive letter (for example: D:/users/mbg/
workarea), can be used on UNIX/Linux only when environment variable(s)
DOS_DRIVE_# are defined. Content of the respective environment variable replaces
the first two letters (D:) in the file name, and the expanded file name must fit within
200 characters. Alternatively, the DOS_DRIVE_# option can be specified in the config
file. UNC format (//server/path/filename) is not accepted.
Each line of data contains up to ten fields in free format. Entries in the free format are
separated by any number of characters from the following set:
(blank)
, (comma)
(
)
=
File names and titles (TITLE, SUBTITLE, LABEL) are exceptions to this rule.
P2G / K2GG / M2GG / B2GG entries allow more than ten fields per line (up to
CARDLENGTH limit).
GROUNDCHECK / WEIGHTCHECK / EIGVRETRIEVE / XYPLOT allow more than ten fields
per line and are the only entries which allow continuation.
Dollar signs, $, in any column denote comments. All characters after the dollar sign
until the end of the line are ignored. A dollar sign can be a part of a file name or title,
but the full title or file name must be enclosed in quotes (" or ) in such cases.
Lines which begin with two slashes, //, or a pound symbol, #, are read as comment
lines. Blank lines are also assumed to be comment lines.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Continuation lines are marked with a trailing comma character in the preceding line.
Numeric entries must start with a digit, +, or -.
Integer entries may not contain decimal points or exponent parts, and must fit in the
range of values allowed for INTEGER*4 (usually 2**31<x<2**31).
Integer data placed in the field reserved for real valued data is accepted and
converted to a double precision.
Character entries longer than eight characters are silently truncated, except for the
title strings and file names. All character strings, except user-provided labels, titles,
and file names, are case insensitive (can be typed in lower or upper case). File names
are always case sensitive, except with Windows, where the operating system does not
care for case.
Abbreviated keyword entries are accepted and recognized properly using the first four
characters. When a four character abbreviation is not unique, the full length keyword
has to appear on the data line (but only the first eight characters are used if the
keyword is longer).

Examples

The following three lines are equivalent:


DISPLACEMENT (form) = option
disp FORM option
displa ,, form , oPTIOn

The following is a card with multiple continuation lines:


XYPLOT, XYPEAK, VELO, PSDF / 3(T2),
6(T2), 8(T2), 10(T2),
20(T2)

The following is a path split across several lines:


INCLUDE "path/
/split into multiple / lines
/filename.txt "
is equivalent to:
INCLUDE "path//split into multiple / lines/filename.txt "
Note that several spaces, the space at the end in particular, which are valid parts of this
name, may cause unexpected results.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Guidelines for Bulk Data Entries


The following guidelines apply to all entries in the bulk data section:
Data may contain 80 characters per line at most. All characters after the 80th are
ignored. The only exception is for the INCLUDE data entry. SYSSETTING,CARDLENGTH
can be used to change the number of characters allowed in each line.
Each line of data contains up to nine fields in one of the three accepted formats:
Fixed Format
Each field consists of eight characters (shown below).

Large Field Fixed Format


Each field consists of 16 characters; two consecutive lines form nine fields, similar to
other formats (shown below). Large field format is recognized by the first character
after the keyword, or by the first character in each continuation line, which must be
*. The second line (half line), if present, must also contain * in the first column.
The first and last field in each half line is eight characters long. The last field on each
first half-line and the first field on each second half-line are ignored.

The following examples show the same card in fixed and large field formats:

Free Format
Fields are separated by commas; blank characters surrounding commas are not
significant. Two consecutive commas define empty (blank) fields. If a comma is
present in a line of data, it is assumed to be free format data. Continuation lines for
free format start with a blank, '+' or '*'.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Large field free format and short field free format are available, but there is no limit on
the length of entries, and all floating numbers are read and stored with full precision
(64-bit REAL*8) in either case. The only difference between large and short free
format is that the latter allows for 8 data fields in each line (in positions 2 9), while
the former allows for 4 data fields per line (similar to the large field fixed format
detailed above).
If there is a comma within the first 10 characters in a line, the line is assumed to be in
free format; otherwise, if there is an '*' immediately after the card name or a
continuation line starts with '*', then the line is accepted as large field fixed format.
All other lines are read in as fixed format.
Use of fixed format limits the range of integer data (-9,999,999 .. 99,999,999) and the
accuracy of floating point numbers, but does not influence the internal storage of data
in particular all floating point numbers are always read and stored with full precision
(64-bit REAL*8).
Bulk data is always limited to 9 fields per line. Content of 10th field and the first field
of each continuation line are silently skipped when fixed format is used (other codes
can use these fields for special purposes, such as to mark matching continuation lines).
Extensions of free format (which may allow more than 9 fields in a line) are not
accepted. An error message is issued when a free format card contains more than 9
fields. This error can be disabled (changed to non-fatal warning) through the use of
SYSSETING,SKIP10FIELD.
Dollar signs, $, in any column denote comments. All characters after the dollar sign
until the end of the line are ignored. Dollar signs can only appear in quoted files
names.
Lines which begin with two slashes, //, or a pound symbol, #, are read as comment
lines. Blank lines are also assumed to be comment lines.
The full keyword of each bulk data entry must be given starting from the first column.
Abbreviated keywords are not allowed.
The format of most bulk data entries is similar to that for Nastran. Not all entry
options are supported by OptiStruct. Consult the list of fields and options supported.
Continuation entries must follow the parent entries. If the first character of any entry
is either a blank, a +, or an *, it is treated as a continuation of the previous entry.
If the entire line is blank, it is treated as a comment line.
An ENDDATA entry or end-of-file denotes end of data. Lines after the ENDDATA entry
are ignored.
All Bulk Data entries must appear after the BEGIN BULK statement in the input data.
The content of the tenth field in each card, and that of the first field in each
continuation card, is disregarded.
Each entry can be placed anywhere within the field. For example, blanks preceding
and following an entry are ignored, except the keyword entry, which must be left
justified in its field.

10

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

No entry can contain blanks within the data.


Character entries (labels) must start with a letter.
Numeric entries must start with a digit, + or -.
Integer entries may not contain a decimal point or an exponent part, and must fit in
the range of values allowed for INTEGER*4 (usually 2**31<x<2**31).
Integer data placed in the field reserved for real valued data is accepted and
converted to a double precision. However, certain fields have alternate functions
where the nature of the number entered indicates the desired function; one function
requires an integer while the other requires a real number in this case, no conversion
is performed.
Real valued data can be entered without exponent part, with exponent part and
explicit letter E or D or with exponent part starting with a sign (without E or D). All
real values are stored internally as double precision data (64-bit REAL*8) without
regards to which format was used to enter them. Following are valid examples of input
for real valued data:
1.
0.1
.1
+.1
-0.1
1e5
1e+5
1+5
1.0E-5
.1d-5
.00001-05
Character entries longer than eight characters are silently truncated in large field and
free field formats, with the exception of file names on the INCLUDE entry (see
documentation for INCLUDE entry) and the LABEL field on DESVAR, DRESP1, DRESP2,
DRESP3, and DTABLE entries (allows up to 16 characters).
Continuation lines do not have to be in the same format as the parent entries. It is
allowed to mix lines in different formats within a single bulk data card.
Invisible tab characters are equivalent to the number of spaces needed to advance to
the nearest tab stop. Tab stops are placed at the beginning of each eight-character
field. Use the SYSSETTINGS,TABSTOPS option to change this value, for example, to
tab stops at 4-character fields.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

11

Replication of GRID data


Replication is a limited data generation capability which may be used for GRID data
only.
Duplication of fields from the preceding GRID entry is accomplished by coding the
symbol =.
Duplication of all trailing fields from the preceding entry is accomplished by coding
the symbol ==.
Incrementing a value from the previous entry is indicated by coding *x or *(x),
where x is the value of the increment. x should be a real number for real fields
or an integer for integer fields. The parentheses will be ignored and removed.
Only the fields for ID, CP, X, Y, Z, and CD can be incremented. The PS data
cannot be incremented.
Replication data can follow other replication data.
Entered entries:
GRID,101,17,1.0,10.5,,17,3456
GRID,*1,=,*(0.2),==
GRID,*100,,=,=,*10.0,==
GRID,20,17,==
Generated entries:
GRID

101

17

1.0

10.5

17

3456

GRID

102

17

1.2

10.5

17

3456

GRID

202

1.2

10.5

10.0

17

3456

GRID

20

1.2

10.5

10.0

17

3456

17

Removal of duplicate entries


Removal of duplicate entries is a limited to GRID, CORD1R, CORD1C, CORD1S, CORD2R,
CORD2C, CORD2S, CORD3R, and CORD4R entries only.
To be considered duplicates, the GRID ID, CP, CD, and PS fields must be the same.
The GRID coordinates should be the same within the setting determined by
PARAM,DUPTOL.
For the coordinate information to be considered duplicate, the CID and GID must be
the same and the vector components and axis locations must be the same within the
setting determined by PARAM,DUPTOL.
The removal of duplicated GRID data is performed after any GRID data is generated
using the GRID replication feature.
For all other cards which require a unique ID, it is an error if any given ID appears more
than once. However, to facilitate application of changes resulting from optimization, it
is possible to redefine content of some cards using a separate file defined with

12

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ASSIGN,UPDATE.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

13

Solution Sequences - Data Selectors (Table)

Key:
R

Required Data Selector.

Optional Data Selector. All optional data selectors can be set equal to zero in order to
override inheritance from default settings (data selectors appearing before the first
subcase).

Either one of the selectors marked E are required, both are optional.

Exactly one selector marked A is required.


Data selector may be defined above the first subcase, in which case it is used in any
subcase where it is allowed (as long as it has not been defined specifically).

**

METHOD(Fluid) and SDAMPING(Fluid) are allowed when the model does not contain fluid
parts, but a warning is issued in such cases.

Direct Frequency and Transient solutions only allow reference of FREQ, FREQ1 and
FREQ2. Modal Frequency and Transient solutions also allow reference of FREQ3, FREQ4
and FREQ5.

14

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Summary of Defaults for I/O Options


Output Format Controls

Card

When card is not


present

When card is present,


but no argument is
given

FORMAT

HM & H3D*

error

OUTPUT

no effect

no effect

*The OptiStruct Configuration File may be used to change the default


settings.

Run Controls

Card

When card is not


present

When card is present,


but no argument is
given

CHECK

no effect

active (has no arguments)

CMSMETH

no effect

no effect

RESTART

no effect

<prefix of filename>.sh

SYSSETTING

no effect

no effect

@HyperForm

no effect

active (has no arguments)

File Names, Headers, and Locations

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

15

Card

When card is not


present

When card is present,


but no argument is
given

ASSIGN

N/A

error

EIGVNAME

OUTFILE is used

error

INCLUDE

N/A

error

LOADLIB

N/A

error

OUTFILE

prefix of filename

error

SUBTITLE

N/A

blank

TITLE

N/A

blank

TMPDIR

./ or .\

error

Card

When card is not


present

When card is present,


but no argument is
given

ACCELERATION

NONE

ALL

AUTOSPC

NO

YES

CONTF

NONE

ALL

CSTRAIN

NONE

ALL

CSTRESS

NONE

ALL

DAMAGE

NONE

ALL

DISPLACEMENT

ALL

ALL

EDE

NONE

ALL

Analysis Output

16

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Card

When card is not


present

When card is present,


but no argument is
given

EKE

NONE

ALL

ELFORCE

See FORCE

ELSTRESS

See STRESS

ENERGY

NONE

ALL

ERP

NONE

ALL

ESE

NONE

ALL

FLUX

NONE

ALL

FORCE

NONE

ALL

FORMAT

no effect

FLX

GPFORCE

NONE

ALL

GPKE

NONE

ALL

GPSTRESS

NONE

ALL

GSTRESS

See GPSTRESS

LIFE

NONE

ALL

MBFORCE

no effect

ALL

MECHCHECK

no effect

N/A

MODALDE

NONE

ALL

MODALKE

NONE

ALL

MODALSE

NONE

ALL

MPCFORCE

NONE

ALL

OLOAD

NONE

ALL

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

17

18

Card

When card is not


present

When card is present,


but no argument is
given

PFGRID

NONE

error

PFMODE

NONE

error

PFPANEL

NONE

error

PFPATH

NONE

error

POWERFLOW

NONE

ALL

PRESSURE

ALL

ALL

PRETBOLT

NO

YES

REQUEST

NONE

error (has no arguments)

SACCELERATION

NONE

ALL

SDISPLACEMENT

NONE

ALL

SINTENS

NONE

ALL

SPCFORCE

NONE

ALL

SPL

NONE

ALL

SPOWER

NONE

ALL

STRAIN

NONE

ALL

STRESS

ALL

ALL

SVELOCITY

NONE

ALL

TCURVE

N/A

blank

THERMAL

NONE

ALL

THIN

NONE

ALL

UNITS

NONE

error (has no arguments)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Card

When card is not


present

When card is present,


but no argument is
given

VELOCITY

NONE

ALL

XTITLE

N/A

blank

XYPEAK

NONE

error

XYPLOT

NONE

error

XYPUNCH

NONE

error

YTITLE

N/A

blank

Except for frequency response subcases, where the default is NONE.


Except for frequency response and transient subcases, where the
default is NONE.

Optimization Output

Card

When card is not


present

When card is present,


but no argument is
given

DENSITY

ALL

ALL

DESGLB

no effect

error

DESHIS

ALL

ALL

DSA

no effect

error

HISOUT

15

15

PROPERTY

FILE

FILE

RESPRINT

no effect

no effect

RESULTS

FL

FL

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

19

Card

When card is not


present

When card is present,


but no argument is
given

SENSITIVITY

NONE

NOSTRESS

SENSOUT

FL

FL

SHAPE

ALL

ALL

THICKNESS

ALL

ALL

Other Output Controllers

20

Card

When card is not


present

When card is present,


but no argument is
given

DMIGNAME

AX

AX

ECHO

no effect

active

ECHOON

no effect

active (has no arguments)

ECHOOFF

no effect

active (has no arguments)

MODEL

ALL

ALL

MSGLMT

no effect

error

OFREQUENCY

ALL

ALL

OMODES

ALL

ALL

OTIME

ALL

ALL

SCREEN

NONE

OUT

TTERM

NONE

REAL

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Random Response

Card

When card is not


present

When card is present,


but no argument is
given

RCROSS

NONE

ERROR

Card

When card is not


present

When card is present,


but no argument is
given

DGLOBAL

NONE

ERROR

Card

When card is not


present

When card is present,


but no argument is
given

HYBDAMP

NONE

ERROR

RADSND

no effect

ERROR

Optimization

FE Analysis

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

21

I/O Options Section

22

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

@HYPERFORM
I/O Options Entry
@HyperForm - One-step Stamping Simulation Run
Description
The @HyperForm statement indicates an input file for one-step stamping simulation written
from HyperForm.
Format
@HyperForm
Comments
1.

Must be present as the first line of the input file to allow the one-step stamping related
bulk data entries to be accepted as input.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

23

ACCELERATION
I/O Options and Subcase Information Entry
ACCELERATION - Output Request
Description
The ACCELERATION command can be used in the I/O Options or Subcase Information sections
to request acceleration vector output for all subcases or individual subcases respectively.
Format
ACCELERATION(sorting,format,form,rotations,random,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format


(.pch file) or the OUTPUT2 format (.op2 file) output
for normal modes, frequency response, and
transient subcases. It will be ignored without
warning if used elsewhere.

Default = blank

format

SORT1:

Results for each frequency/


timestep are grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment
8).

blank:

For frequency response analysis,


if no grid SET is specified, SORT1
is used, otherwise, SORT2 is
used; for transient analysis,
SORT2 is used.

<HM, H3D, HG, OPTI, HM:


PUNCH, OP2, PLOT,
blank>
H3D:
Default = blank
HG:

24

Results are output in HyperMesh


binary format (.res file).
Results are output in Hyper3D
format (.h3d file).
Results are output in HyperGraph
presentation format (_freq.mvw
file and _tran.mvw file) see
OUTPUT keywords HGFREQ and
HGTRANS.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
OPTI:

Results are output in OptiStruct


results format (.dispfile).

PUNCH:

Results are output in Nastran


punch results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 11).

PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the
bulk data section.
If PARAM, POST is not defined in
the bulk data section, this format
allows the form for complex
results to be defined for XYPUNCH
output without having other
output.

form

<COMPLEX, REAL,
IMAG, PHASE,
BOTH>

blank:

Results are output in all active


formats for which the result is
available.

COMPLEX (HM
only), blank:

Provides a combined magnitude/


phase form of complex output to
the .res file for the HM output
format.

Default (HM only) =


COMPLEX
REAL or IMAG:
Default (all other
formats) = REAL
PHASE:

Provides rectangular format (real


and imaginary) of complex output
(See comment 9).
Provides polar format (magnitude
and phase) of complex output.
Phase output is in degrees (See
comment 9).

BOTH (HM only): Provides both polar and


rectangular formats of complex
output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

25

Argument

Options

Description

rotations

<ROTA, NOROTA>

ROTA:

Requests output of rotational


acceleration results (in addition
to translational acceleration
results).

NOROTA:

Rotational acceleration results are


not output.

PSDF:

Requests PSD and RMS results


from random response analysis to
be output.

Default = NOROTA

random

<PSDF, RMS>
No default

Only valid for the H3D format.


The "RMS over Frequencies"
output is at the end of the
Random results.
RMS:

Requests only the RMS over


Frequencies result from random
response analysis to be output.
Valid only for the H3D format.

peakoutput

<PEAKOUT>

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the
PEAKOUT card will be considered
for this output.

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank:

Acceleration is output for all


nodes.

Default = ALL

NO, NONE:

Acceleration is not output.

SID:

If a set ID is given, acceleration


is output only for nodes listed in
that set.

Default = blank

option

26

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

When the ACCELERATION command is not present, acceleration results are not output.

2.

Acceleration output is only available for frequency response and transient analysis
solution sequences.

3.

The form argument is only applicable for frequency response analysis. It is ignored for
other analysis types.

4.

The forms BOTH and COMPLEX do not apply to the .frf output files.

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on the results available and their respective formats.

6.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

7.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as
it does not allow different frequencies for different formats.

8.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

9.

Results in binary format (.h3d or .op2) are always output in PHASE/MAG form, regardless
of the options specified in the FORM field. The corresponding post-processors
(HyperView/HyperGraph) can easily convert the PHASE/MAG format to the required
formats. Results in ASCII formats are output in the specified/requested FORM.

10. The abbreviations ACCE and ACCEL are interchangeable with ACCELERATION.
11. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

27

ASSIGN
I/O Options and Subcase Information Entry
ASSIGN Input Definition
Description
The ASSIGN command can be used in the I/O Options section to identify external files and
their contents.
Format
ASSIGN, type, option1, option2

Type

Option1

Option 2

Description

AKUSMOD

filename

N/A

Identifies an external file from which to read the


AKUSMOD fluid-structure coupling matrix.
If this is not defined, it is presumed that the
AKUSMOD coupling matrix is to be found in the same
directory as the solver input file and is given the file
name, ftn.70.
Use of the AKUSMOD fluid-structure coupling matrix
requires the presence of PARAM,AKUSMOD,YES.

ENGINE

SUBCASE ID

filename

Identifies an external file from which to read


modification commands to be applied on the
intermediate RADIOSS Engine file translated in the
NLGEOM, IMPDYN and EXPDYN solutions.
SUBCASE ID=0 means all NLGEOM, IMPDYN and
EXPDYN subcases.
See comment 1.

EXCINP

SUBCASE ID

filename

Identifies an external file from which to read the


modal participation factors calculated by AVL/
EXCITE for both transient and FRF residual runs.
While running an AVL/EXCITE analysis, a .INP4 file is
generated that contains the modal participation
factors. The .INP4 file can be used along with the
original flex h3d file to recover stresses, strains,
displacements, velocities, and accelerations from a

28

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type

Option1

Option 2

Description
dynamic analysis run. The SUBCASE ID is used to
specify which SUBCASE the modal participation
factors should be used for.

H3DDMIG

matrixname

filename

Identifies an external nodal flexh3d file from which to


read DMIG matrices. Provides a prefix (matrixname)
for the matrices contained therein, and the path to
and the name of the flexh3d file. All of the matrices
in the h3d file are used in the analysis by default. If
only some of the matrices are to be used, then use
the K2GG, M2GG, K42GG, and B2GG data to specify
which matrices are to be used. The unreferenced
matrices will not be used in this case.

H3DCAA

Load ID

filename

Identifies an external file that contains information


necessary for Computational Aero-Acoustic (CAA)
analysis. The information in this external file is then
used to conduct frequency response analyses. This
file (.h3d format) is currently generated by
AcuSolve and includes pressure values from
Computational Fluid Dynamics (CFD) Analysis at
each loading frequency. The specified LoadID can
be referenced by CAALOAD data (CAAID field) for
the application of load in a model.

H3DCDS

matrixname

filename

Identifies an external file from which to read complex


dynamic matrices for a CDS residual run. Provides a
prefix (matrixname) for the matrices contained
therein and the path to and the name of the
filename_CDS.h3d file. All of the matrices in the
filename_CDS.h3d file are used in the analysis.

H3DMBD

Flex Body ID

filename

Identifies an external nodal flexh3d file which


contains the analysis recovery information for
displacements, velocities, accelerations, stresses
and strains. Provides a Flex Body ID for the
information therein, and the path to and the name
of the flexh3d file.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

29

Type

Option1

Option 2

Description

MBDINP

SUBCASE ID

filename

Identifies an external file from which to read the


modal participation factors calculated by
MotionSolve for transient analysis.
While running MotionSolve, an .mrf file is generated
that contains the modal participation factors. The
.mrf file can be used along with the original flex h3d
file to recover stresses, strains, displacements,
velocities, and accelerations during a transient
analysis run. The SUBCASE ID is used to specify
which SUBCASE the modal participation factors
should be used for.

MMO

Model Name

filename

Identifies an external file to be included in a MultiModel Optimization (MMO) run. Model Name is a
user-defined label for the model, which can be used
to qualify model-specific responses referenced on
the DRESPM continuation lines of the DRESP2/
DRESP3 entries.

PUNCH

filename

N/A

Identifies an external file as the location to write


DMIG data in PUNCH format.

STARTER

SUBCASE ID

filename

Identifies an external file from which to read


modification commands to be applied on the
intermediate RADIOSS Starter file translated in the
NLGEOM, IMPDYN and EXPDYN solutions.
SUBCASE ID=0 means all NLGEOM, IMPDYN and
EXPDYN subcases.
See comment 1.

SIMPINP

30

SUBCASE

filename

Identifies an external .unv file generated while


running a multi-body dynamic analysis in SIMPACK.
The resulting CMS flexbody modal participation
factors in the .unv file can be used by OptiStruct to
recover the dynamic displacements, velocities,

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type

Option1

Option 2

Description
accelerations, stresses and strains.
The SUBCASE ID is used to specify which SUBCASE
the modal participation factors should be used for.

UPDATE

filename

N/A

Identifies an external file from which to read the


updated cards after an optimization run.
Currently, the following cards are supported:
GRID
MAT1, MAT2, MAT3, MAT4, MAT5, MAT8, MAT9,
MAT10
PSHELL, PSOLID, PBAR, PBEAM, PELAS, PVISC,
PDAMP, PBARL, PBEAML, PMASS, PROD, PBUSH,
PBUSH1D, PACABS
PAABSF, PWELD, PCOMPP, PSHEAR, PTUBE
CTRIA3, CQUAD4, CTRIA6, CQUAD8
CONM2

Examples
ASSIGN, PUNCH, C:\CMS\h3ddmig.pch
ASSIGN, H3DDMIG, AX, C:\CMS\h3ddmig.h3d
Comments
1.

For geometric nonlinear subcases, two types of modification commands are available in
the external file defined with ASSIGN,STARTER/ENGINE: insert and replace.
insert
Usage:

Inserts content between keywords /INSERT and /ENDINS to the


intermediate RADIOSS Block deck at line number LINENUM.

Syntax:

/INSERT,LINENUM
Content to be inserted
/ENDINS

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

31

replace
Usage:

Uses content between keywords /REPLACE and /ENDREP to replace the


content in the intermediate RADIOSS Block deck between line numbers
LINENUM1 and LINENUM2.

Syntax:

/REPLACE,LINENUM1, LIMENUM2
Content as replacement
/ENDREP

2.

The SEINTPNT subcase information entry can only be used to convert interior super
element grid points in .h3d files referenced by ASSIGN, H3DDMIG.
Limitations:
Each subcase can only be defined with a maximum of one ASSIGN,STARTER entry and
one ASSIGN,ENGINE entry.
In the external file, the line numbers (LINENUM after /INSERT, and LINENUM1 after /
REPLACE) should be input in increasing order.
For subcases in the same load sequence (defined by CNTNLSUB), ASSIGN,STARTER
settings should be identical.

32

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

AUTOSPC
I/O Options Entry
AUTOSPC - Automatically Constrains Stiffness Singularities
Description
The AUTOSPC command requests that stiffness singularities and near singularities be
constrained automatically with single point constraints.
Format

Argument

Description

PRINT

Enables the printout of a summary table of singularities.


(Default)

NOPRINT

Disables the printout of a summary table of singularities.

PUNCH

Creates a PUNCH file with SPC data for each AUTOSPC DOF
for each SUBCASE. The SPC SID is the SUBCASE ID.

NOPUNCH

Do not create a PUNCH file with SPC data for each


AUTOSPC DOF for each SUBCASE.
(Default)

Comments
1.

YES is the default.

2.

Replaces parameters PARAM,AUTOSPC and PARAM,PRGPST.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

33

CDSMETH
I/O Options Entry
CDSMETH Run Control
Description
The CDSMETH command can be used in component dynamic synthesis method for generating
component dynamic matrices at each loading frequency.
Format
CDSMETH = CDSID
Example
CDSMETH = 10

Argument

Option

Description

CDSID

<INTEGER>

ID of CDSMETH in bulk data section.

Default = NONE

Comments
1.

If CDSMETH is specified, only one subcase is allowed. The data corresponding to


component dynamic synthesis will be stored in an H3D file with the name,
filename_CDS.h3d.

2.

The subcase must be a modal frequency response subcase, except it does not require a
DLOAD card for load specification.

34

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHECK
I/O Options Entry
CHECK - Run Control
Description
The CHECK command can be used in the I/O Options section to request that only a model
check be performed.
Format
CHECK
Comments
1.

Perform model check only.

2.

If this keyword is present, only the subroutines which read in the input files are executed.
A report that provides information on errors in the model and the memory and disk space
requirements is given.

3.

Useful for large runs since the amount of memory and time required to perform this
function is very small.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

35

CMDE
I/O Options Entry
CMDE - Output Request
Description
The CMDE command can be used above the first SUBCASE or within a SUBCASE definition to
request component modal synthesis damping energy output for all subcases or individual
subcases respectively.
Format
CMDE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=type)
= option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

blank:

Results are output in all active


formats for which the result is
available.

Default = blank

thresh

Specifies an absolute threshold under which results


should not be output.

<Real>
No default

rthresh

Specifies a relative threshold under which results


should not be output. This value is relative to the
corresponding total modal energy.

<Real>
No default

topn

<Integer>

Specifies that only the top N values should be


output.

No default

36

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

type

<AVERAGE,
AVERAGE:
AMPLITUDE, PEAK>

The average of the energy is


output.

Default = AVERAGE

AMPLITUDE:

The amplitude of the energy is


output.

PEAK:

The peak energy is output. This


is the sum of AVERAGE and
AMPLITUDE.

mset

Description

<ALL, SID, TOTAL> ALL:


Default = ALL

option

<YES, ALL, NO,


NONE>
Default = ALL

Modal energy is output for all


modes.

SID:

If a set ID is given, modal energy


is output only for modes listed in
that set.

TOTAL:

Only the total energy is output.

YES, ALL, blank: Modal energy is output.

NO, NONE:

Modal energy is not output.

Comments
1.

When the CMDE command is not present, component modal synthesis damping energy is
not output.

2.

Component modal synthesis damping energy output is only available for frequency
response analysis (both direct and modal methods). It is intended for use when external
CMS superelements are used.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as
it does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

37

CMKE
I/O Options Entry
CMKE - Output Request
Description
The CMKE command can be used above the first SUBCASE or within a SUBCASE definition to
request component modal synthesis kinetic energy output for all subcases or individual
subcases respectively.
Format
CMKE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=type)
= option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

blank:

Results are output in all active


formats for which the result is
available.

Default = blank

thresh

Specifies an absolute threshold under which results


should not be output.

<Real>
No default

rthresh

Specifies a relative threshold under which results


should not be output. This value is relative to the
corresponding total modal energy.

<Real>
No default

topn

<Integer>

Specifies that only the top N values should be


output.

No default

38

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

type

<AVERAGE,
AMPLITUDE, PEAK>

AVERAGE:

The average of the energy is


output.

Default = AVERAGE

AMPLITUDE:

The amplitude of the energy is


output.

PEAK:

The peak energy is output. This


is the sum of AVERAGE and
AMPLITUDE.

mset

<ALL, SID, TOTAL> ALL:


Default = ALL

option

Modal energy is output for all


modes.

SID:

If a set ID is given, modal energy


is output only for modes listed in
that set.

TOTAL:

Only the total energy is output.

<YES, ALL, NO,


NONE>

YES, ALL, blank: Modal energy is output.

Default = ALL

NO, NONE:

Modal energy is not output.

Comments
1.

When the CMKE command is not present, component modal synthesis kinetic energy is not
output.

2.

Component modal synthesis kinetic energy output is only available for frequency response
analysis (both direct and modal methods). It is intended for use when external CMS
superelements are used.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as
it does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

39

CMSE
I/O Options Entry
CMSE - Output Request
Description
The CMSE command can be used above the first SUBCASE or within a SUBCASE definition to
request component modal synthesis strain energy output for all subcases or individual
subcases respectively.
Format
CMSE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=type)
= option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

blank:

Results are output in all active


formats for which the result is
available.

Default = blank

thresh

Specifies an absolute threshold under which results


should not be output.

<Real>
No default

rthresh

Specifies a relative threshold under which results


should not be output. This value is relative to the
corresponding total modal energy.

<Real>
No default

topn

<Integer>

Specifies that only the top N values should be


output.

No default

40

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

type

<AVERAGE,
AMPLITUDE, PEAK>

AVERAGE:

The average of the energy is


output.

Default = AVERAGE

AMPLITUDE:

The amplitude of the energy is


output.

PEAK:

The peak energy is output. This is


the sum of AVERAGE and
AMPLITUDE.

ALL:

Modal energy is output for all


modes.

SID:

If a set ID is given, modal energy is


output only for modes listed in that
set.

TOTAL:

Only the total energy is output.

YES, ALL,
blank:

Modal energy is output.

NO, NONE:

Modal energy is not output.

mset

<ALL, SID,
TOTAL>
Default = ALL

option

<YES, ALL, NO,


NONE>
Default = ALL

Comments
1.

When the CMSE command is not present, component modal synthesis strain energy is not
output.

2.

Component modal synthesis strain energy output is only available for frequency response
analysis (both direct and modal methods). It is intended for use when external CMS
superelements are used.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

41

5.

42

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as
it does not allow different frequencies for different formats.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CONTF
I/O Options and Subcase Information Entry
CONTF Output Request for Contact Results
Description
The CONTF entry can be used in the I/O Options or Subcase Information sections to request
contact results output for all nonlinear analysis subcases or individual nonlinear analysis
subcases respectively.
Format
CONTF (format, type) = option

Type

Options

Description

format

<H3D, OPTI,
blank>

H3D:

Results are output in Hyper3D format


(.h3d file). See below for type.

OPTI:

The total contact force results are


output to the .cntf file.

blank:

Results are output in all active


formats for which the result is
available.

ALL:

All available contact results types


are output.

FORCE:

Contact force results are output.

PCONT:

Pressure-type contact results are


output: pressure, open-closed
status, contact gap opening and
penetration (see comment 2).

FRICT:

Friction-related results are output:


frictional traction, sliding distance,
and stick-slip status (see comment
2).

YES, ALL,

Contact results are output for all grid

Default = blank

type

<ALL,FORCE,
PCONT,FRICT>
Default = ALL

option

<YES, ALL,

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

43

Type

Options

Description

NO, NONE,
SID>

blank:

points.

Default = ALL

NO, NONE:

Contact results are not output.

SID:

If a set ID is given, contact results


are output only for grid points listed
in that set.

Comments
1.

The CONTF entry is only applicable in nonlinear analysis subcases that are identified by the
presence of an NLPARM subcase entry. The specific detailed result types displayed differ
slightly between NLSTAT and geometrically nonlinear subcases.

2.

Most of the contact results are real numbers and are self-explanatory. Some results that
may require clarification are listed below:
Open/Closed status is represented by 0.0 for Open and 1.0 for Closed. On graphical
display, intermediate values may appear due to transition from open to closed across
individual elements,
Slip/Stick Status is represented by 0.0 for Open, 1.0 for Slip and 2.0 for Stick. On
graphical display, intermediate values may appear due to transition of status across
individual elements,
Sliding Distance represents total sliding distance accumulated while the surfaces are in
contact. This may be different than just the difference in displacements between the
starting and final position.

3.

The calculation of contact results on both sides of contact interface involves projections
and mappings. Therefore, a perfect match of results between two sides cannot be
expected, especially on mismatched meshes. Also, the resolution of different types of
results (pressure versus gap opening) differs according to their respective FEA
interpolation order. Therefore, such results may appear locally inconsistent, especially on
second order meshes and mismatched mesh densities. (Usually pressure and traction will
appear smoother than gap opening or penetration.)

4.

Only formats that have been activated by an OUTPUT or FORMAT statement are valid for
use on this entry.

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for further
information.

6.

Multiple instances of this entry are allowed; if the instances conflict, the last instance
dominates.

44

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSTRAIN
I/O Options and Subcase Information Entry
CSTRAIN - Output Request
Description
The CSTRAIN command can be used in the I/O Options or Subcase Information sections to
request ply strain output for elements referencing PCOMP or PCOMPG properties for all
subcases or individual subcases respectively.
Format
CSTRAIN (format_list,type,extras_list) = option

Argument

Options

Description

format

<HM, H3D, OPTI,


PUNCH, OP2, PLOT,
blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in OptiStruct


results format (.cstr file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 10).

PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the bulk
data section.

blank:

Results are output in all active


formats, for which the result is
available.

Default = blank

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

45

Argument

Options

Description

type

<ALL, PRINC>

ALL, blank:

All strain results are output.

PRINC:

Only principal strain results are


output.

MECH:

Output Mechanical strain (in


addition to total strain). This
output is only available for H3D
format.

THER:

Output Thermal strain (in addition


to total strain). This output is only
available for H3D format.

<YES, ALL, NO,


NONE, SID, PSID>

YES, ALL, blank:

Results are output for all elements.

Default = YES

NO, NONE:

Results are not output.

SID:

If a set ID is given, results are


output only for elements listed in
that set.

PSID:

If a property set ID is given, results


for the elements referencing
properties listed in the property set
are output.

Default = ALL

extras

<MECH, THER>
No default

option

Comments
1.

When the CSTRAIN command is not present, ply strain results are not output.

2.

This output is not currently available for the frequency response or transient solution
sequences.

3.

The STRAIN I/O option controls the output of strain results for the homogenized
composite material.

46

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands, for which the result is available. See Results Output for information
on which results are available in which formats.

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

The SOUT field on the PCOMP or PCOMPG bulk data entry must be set to YES to activate
strain results calculation for the corresponding ply.

7.

For plies defined on a PCOMPG bulk data entry, the results are grouped by GPLYID.

8.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

9.

The mechanical and thermal contributions to strain may be requested in addition to the
total strain.

10. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

47

CSTRESS
I/O Options and Subcase Information Entry
CSTRESS - Output Request
Description
The CSTRESS command can be used in the I/O Options or Subcase Information sections to
request ply stress and failure index output for elements referencing PCOMP or PCOMPG
properties for all subcases or individual subcases respectively.
Format
CSTRESS (format_list,type) = option

Argument

Options

Description

format

<HM, H3D, OPTI,


PUNCH,OP2, blank>

HM:

Results are output in HyperMesh


results format (.res file).

Default = blank

H3D:

Results are output in Hyper3D format


(.h3d file).

OPTI:

Results are output in OptiStruct results


format (.cstr file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 10).

blank:

Results are output in all active


formats, for which the result is
available.

type

<ALL, PRINC, FI>


Default = ALL

48

ALL, blank:

All stress results are output.

PRINC:

Only principal stress results are


output.

FI:

Only failure index results are


output. Failure Index results are
not available in the .pch and .op2
files.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

Option

<YES, ALL, NO,


NONE, SID, PSID>

YES, ALL,
blank:

Results are output for all


elements.

Default = YES

NO, NONE:

Results are not output.

SID:

If a set ID is given, results are


output only for elements listed in
that set.

PSID:

If a property set ID is given,


results for the elements
referencing properties listed in the
property set are output.

Comments
1.

When the CSTRESS command is not present, ply stress and failure index results are not
output.

2.

This output is not currently available for the frequency response or transient solution
sequences.

3.

The STRESS I/O option controls the output of stress results for the homogenized
composite material.

4.

Multiple formats are allowed on the same entry, these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands, for which the result is available. See Results Output for information
on which results are available in which formats.

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

The SOUT field on the PCOMP or PCOMPG bulk data entry must be set to YES to activate
stress results calculation for the corresponding ply. For Failure Indices to be calculated,
the FT and SB fields on PCOMP or PCOMPG bulk data and stress (or strain) allowables on
the referenced materials need to be defined.

7.

For plies defined on a PCOMPG bulk data entry, the results are grouped by GPLYID.

8.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

9.

Failure Index results are not available in the .pch and .op2 files.

10. format=OUTPUT2 can also be used to request results to be output in the Nastran output2

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

49

format (.op2 file).

50

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DAMAGE
I/O Options and Subcase Information Entry
DAMAGE Output Request
Description
The DAMAGE command can be used in the I/O Options or Subcase Information sections to
request fatigue damage results output for all fatigue subcases or individual fatigue subcases
respectively.
Format
DAMAGE (format, type) = option

Argument

Options

Description

format

<H3D, OPTI,
blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

OPTI:

Results are output in OptiStruct results


format (.fat file).

blank:

Results are output in all active formats for


which the result is available.

SUB:

Only the total damage from the fatigue


subcase is output.

LOAD:

Damage contribution from each static


subcase and total damage from the fatigue
subcases are output.

EVENT:

Damage contribution from each FATEVNT


and total damage from fatigue subcases are
output.

ALL:

Damage contribution from each FATEVNT,


damage contribution from each static
subcase and total damage from fatigue
subcases are all output.

Default = blank

type

<SUB, LOAD,
EVENT, ALL>
Default = SUB

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

51

Argument

Options

Description

option

<YES, ALL, NO,


NONE, SID>

YES, ALL,
blank:

Results are output for all elements.

NO, NONE:

Results are not output.

SID:

If a set ID is specified, results are output


only for elements listed in that set.

Default = ALL

Comments
1.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output by OptiStruct for
information on which results are available in which formats.

2.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

52

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DENSITY
I/O Options and Subcase Information Entry
DENSITY - Output Request
Description
The DENSITY command can be used in the I/O Options section to request density output for a
topology optimization.
Format
DENSITY (format_list,type) = option

Argument

Options

Description

format

<HM, H3D, OPTI,


PUNCH, OP2, PLOT,
blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in OptiStruct


results format (.dens file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 6).

PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the bulk
data section (see comment 6).

blank:

Results are output in all active


formats for which the result is
available.

ALL:

Results are output in all simulations.

DES, blank:

Results are only output in the


design history simulations.

Default = blank

type

<ALL, DES>
Default = DES

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

53

Argument

Options

Description

option

<YES, ALL, NO,


NONE>

YES, ALL,
blank:

Results are output

Default = YES

NO, NONE:

Results are not output.

Comments
1.

When the DENSITY command is not present, density results are output.

2.

Density results are only available for topology optimizations.

3.

Outputting the density results in all simulations allows analysis results to be plotted on
the density iso-surface in HyperView.

4.

The frequency of this output is controlled by the DESIGN keyword on an OUTPUT definition
or, if no OUTPUT definition exists with the DESIGN keyword, by the DENSRES I/O option.

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

6.

Density results are reported as element strain energy in the .op2 file.

7.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

54

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DESGLB
I/O Options Entry
DESGLB Constraint Selection
Description
The DESGLB command can be used in the I/O Options section, before the first subcase
statement, to select a constraint set that is not subcase dependent.
Format
DESGLB = integer

Argument

Options

Description

integer

< SID >

SID:

Set identification of a DCONSTR or DCONADD bulk


data entry.

No default
Comments
1.

The constrained response referenced by the DESGLB constraint selection must not be
subcase dependent.

2.

Only one DESGLB entry can be defined in the I/O options section for the entire model.

3.

This entry is represented as an optimizationconstraint in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

55

DESHIS
I/O Options Entry
DESHIS - Output Control
Description
The DESHIS command can be used in the I/O Options section to control the creation of the
optimization history file .hgdata.
Format
DESHIS = option

Argument

Options

Description

option

<YES, ALL, NO> YES, ALL, blank:


Default = YES

NO:

.hgdata file is created.


.hgdata is not created.

Comments
1.

56

When the DESHIS command is not present, the .hgdata file is created.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DGLOBAL
I/O Options Entry
DGLOBAL - Input Definition
Description
The DGLOBAL command can be used in the I/O Options section to activate the Global Search
Option (GSO).
Format
DGLOBAL = n

Argument

Options

Description

(Integer > 0)

Identification of a DGLOBAL bulk data entry.

No default
Comments
1.

This command must reference a DGLOBAL bulk data entry to run GSO.

2.

This data can exist only once in the I/O section.

3.

This command activates a global search algorithm to run an optimization of user-defined


design variables from multiple starting points.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

57

DISPLACEMENT
I/O Options and Subcase Information Entry
DISPLACEMENT - Output Request
Description
The DISPLACEMENT command can be used in the I/O Options or Subcase Information sections
to request displacement vector output for all subcases or individual subcases respectively.
Format
DISPLACEMENT (sorting,format,form,rotations,random,peakoutput,modal,complex
eigenvalue analysis) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format (.pch


file) or the OUTPUT2 format (.op2 file) output for
normal modes, frequency response, and transient
subcases. It will be ignored without warning if used
elsewhere.

Default = blank

format

58

SORT1:

Results for each frequency/timestep are


grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment 9).

blank:

For frequency response analysis, if no


grid SET is specified, SORT1 is used,
otherwise, SORT2 is used; for transient
analysis, SORT2 is used.

<HM, H3D, OPTI,


PUNCH,OP2,
PATRAN, HG,
APATRAN, PLOT,
blank>

HM:

Results are output in HyperMesh results


format (.res file).

H3D:

Results are output in Hyper3D format


(.h3d file).

Default = blank

OPTI:

Results are output in OptiStruct results


format (.disp file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 12).

PATRAN:

Results are output in Patran format


(multiple files).

HG:

Results are output in HyperGraph


presentation format (_freq.mvw file and
_tran.mvw file) see OUTPUT keywords
HGFREQ and HGTRANS.

APATRAN:

Results are output in Alternative Patran


format (multiple files).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST is
defined in the bulk data section.
If PARAM, POST is not defined in the bulk
data section, this format allows the form
for complex results to be defined for
XYPUNCH output without having other
output.

blank:

form

Results are output in all active formats


for which the result is available.

<COMPLEX,
REAL, IMAG,
PHASE, BOTH>

COMPLEX (HM
only), blank:

Provides a combined magnitude/phase


form of complex output to the .res file
for the HM output format.

Default (HM
only) = COMPLEX

REAL or IMAG:

Provides rectangular format (real and


imaginary) of complex output (See
comment 10).

Default (all other


formats) = REAL PHASE:

Provides polar format (magnitude and


phase) of complex output. Phase
output is in degrees (See comment
10).

BOTH (HM only): Provides both polar and rectangular


formats of complex output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

59

Argument

Options

Description

rotations

<ROTA, NOROTA>

ROTA:

Rotational displacement results are


output. Only works with H3D and HM
output streams. Rotations are always
output with translations for other
output streams.

NOROTA:

Rotational displacement results are not


output. Only works with H3D and HM
output streams. Rotations are always
output with translations for other
output streams.

PSDF:

Requests PSD and RMS results from


random response analysis to be output.

Default =
NOROTA

random

<PSDF, RMS>
No default

Only valid for the H3D format. The


"RMS over Frequencies" output is at
the end of the Random results.
RMS:

Requests only the RMS over


Frequencies result from random
response analysis to be output.
Valid only for the H3D format.

peakoutput <PEAKOUT>

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will
be considered for this output.

MODAL:

If MODAL is present, displacements of


the structural modes and residual
vectors are output to the PUNCH and
OUTPUT2 files for modal frequency
response and transient analysis.

Default = Blank

modal

<MODAL>
Default = Blank

60

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

complex
eigenvalue
analysis

<UNSTABLE>

option

Description
UNSTABLE:

If UNSTABLE is present, the


displacement results from the unstable
modes (only) of a complex eigenvalue
analysis are output.

Blank:

Displacement results are output for all


modes by default (See comment 1).

Default = Blank

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank: Displacement is output for all grids.

Default = ALL

NO, NONE:

Displacement is not output.

SID:

If a set ID is given, displacement is


output only for grids listed in that set.

Comments
1.

When DISPLACEMENT command is not present, displacement is output for all grids for all
subcases, except for frequency response subcases.

2.

The form argument is only applicable for frequency response analysis. It is ignored for
other analysis types.

3.

The forms BOTH and COMPLEX do not apply to the .frf output files.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

7.

Rotation results are output in radians.

8.

For normal modes output, if there is USET U6 data the static residual displacement
vectors associated with the USET U6, DOF are also output to the PUNCH, H3D, and
OUTPUT2 files.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

61

9.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

10. Results in binary format (.h3d or .op2) are always output in PHASE/MAG form, regardless
of the options specified in the FORM field. The corresponding post-processors
(HyperView/HyperGraph) can easily convert the PHASE/MAG format to the required
formats. Results in ASCII formats are output in the specified/requested FORM.
11. The four-letter abbreviation DISP is interchangeable with DISPLACEMENT.
12. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

62

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DMIGNAME
I/O Options Entry
DMIGNAME - Reduced Matrix Name Definition
Description
The DMIGNAME command can be used in the I/O Options section to define the name given to
the reduced matrices written to an external data file.
Format
DMIGNAME = mtxname

Argument

Options

Description

mtxname

<up to 6
characters>

The name given to the reduced matrices written to an


external data file, when PARAM, EXTOUT is present in
the bulk data section.

Default = AX

If PARAM, EXTOUT, DMIGPCH is used, then the file


outfile_mtxname.pch is created.
If PARAM,EXTOUT, DMIGBIN is used, then the file
outfile_mtxname.dmg is created.
Both files contain the matrices:
KAmtxname - reduced stiffness matrix
MAmtxname - reduced mass matrix
Pmtxname - reduced loading matrix
Note: The reduced mass matrix is only output if an
eigenvalue subcase is present in the input file
and the reduced loading matrix is only output if a
linear static subcase is present in the input file.

Comments
1.

When a DMIGNAME command is not present, AX is used for mtxname.

2.

Only one occurrence of DMIGNAME is permitted.

3.

DMIGNAME must appear before the first subcase.

4.

See Direct Matrix Approach in the User's Guide for more detailed usage information.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

63

DSA
I/O Options and Subcase Information Entry
DSA - Design Sensitivity Analysis Output Request
Description
The DSA command can be used in the I/O Options section to request Design Sensitivity
Analysis results in a frequency response analysis.
Format
DSA (TYPE, PEAKOUT, PROPERTY) = SID
Examples
DSA(DISP,PROPERTY)=12
DSA(VELO,PEAKOUT)=45
DSA(ACCE,PEAKOUT,SCALE)=23

Argument

Options

Description

TYPE

<DISP,PRES,VELO The options are Displacement, Pressure, Velocity and


Acceleration respectively.
,ACCE>
Default = DISP

PEAKOUT

Default = blank

PROPERTY

Default = blank

If PEAKOUT is present inside the parentheses of the DSA


entry, the filtered frequencies from the PEAKOUT card
will be considered for DSA results.

If the PROPERTY flag is present:


This indicates that design sensitivities represent the
change in design response due to a change in design
properties (instead of design variables).
If the PROPERTY flag is not present:
This indicates that design sensitivities represent the
change in design response due to a change in design
variables.

64

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

SID

<SID>

Description
SID refers to the ID of a SET of type GRIDC.

Comments
1.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates. If this entry is defined above the first subcase then it is applied to all
subcases. If it is defined within a specific subcase then it is applied to that subcase only.

2.

If the input deck doesn't contain any optimization data (apart from DESVARs), then a
MASS objective function is automatically created along with responses and constraints
corresponding to the DSA request. If the input deck contains a valid optimization setup,
then it's augmented with the DSA request.

3.

In the H3D file, the "SCALE" value is only printed when the PROPERTY argument is not
present within the parentheses of the DSA entry. The sensitivities are pre-scaled when
the PROPERTY argument is present in the DSA entry, so the scaling factor is not required
in the H3D file.

4.

OUTPUT, H3DSENS can be used to include (or exclude) user-defined responses in the DSA
output. The table below lists the sensitivities that are output for each option.

5.

Sensitivities output from a


complete Optimization setup
(User-defined/specified
responses via DRESP1,
DRESP2, DRESP3)

Output

Sensitivities requested via


the DSA output request

OUTPUT, H3DSENS, USER

Yes

Yes

OUTPUT, H3DSENS, NOUSER

Yes

No

(responses are
automatically defined)

Design variables and their corresponding design properties must be defined in the input
deck if sensitivity output is requested through the DSA entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

65

ECHO/ECHOON/ECHOOFF
I/O Options Entry
ECHO - Output Control
ECHOON - Output Control
ECHOOFF - Output Control
Description
The ECHO command can be used in the I/O Options section causing the output of the
interpreted forms of subcase information and bulk data entries to the .out file.
The ECHOON command can be used in the I/O Options, Subcase Information, or Bulk Data
sections causing the (verbatim) output of any subsequent I/O options, subcase information,
or bulk data entries to the .out file until an ECHOOFF command is encountered.
The ECHOOFF command can be used in the I/O Options, Subcase Information, or Bulk Data
sections suppressing the output of any subsequent I/O options, subcase information, or bulk
data entries to the .out file until and ECHOON command is encountered.
Format
ECHO = option1
ECHOON = option2
ECHOOFF
Example
ECHO = SORT(EIGR,EIGRL,ASET1,SPOINT,PARAM,SPC1,SPCADD,MPCADD,
DLOAD,RLOAD2,DAREA,DPHASE,FREQ1,TABLED1,TABDMP1)

Argument Options

Description

option1

<SHORT, PUNCH,
{cardname}, EXCEPT
{cardname}, blank>

SHORT:

Only entries having less than 20


instances are echoed to the .out
file.

<MAT, PROP, ELEM>

PUNCH:

Writes interpreted echo of all


bulk data entries to the .echo
file.

{cardname}:

Only bulk data entries with the


given {cardname} are echoed to
the .out file.

Default = blank

66

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument Options

Option2

Description

<PARSED>

EXCEPT
{cardname}:

Only bulk data entries with the


given {cardname} are not
echoed.

blank:

Writes interpreted forms of all


subcase information and bulk
data entries to the .out file.

MAT, PROP,
ELEM:

Adds all cards of the specified


class to the list for ECHO.

PARSED:

Bulk data entries are converted


to free format (comma
separated) before echoing.

blank:

Bulk data entries are echoed


verbatim.

Default = blank

Comments
1.

When an ECHO command is not present, no input information is echoed.

2.

The interpreted echo always includes SUBCASE cards (solution related), but not output
control cards.

3.

The cards are organized within groups, for example, optimization cards appear after model
definition cards, and most cards are sorted by their numerical IDs.

4.

The interpreted echo may contain some cards that are automatically generated or
converted during reading (for example, a CQUADR card shows as CQUAD4, or a CMASS1 card
shows as a CMASS3 when only scalar points are referenced). Unreferenced cards may not
show in the printout. PARAM,DOPTRM,OSDIAG will not be shown.

5.

ECHO will be produced from internal representation of each card, thus it will be
equivalent, but not identical to the input:
For most of the optional fields, the blank from input will be printed in ECHO as default
value.
Fields which are not recognized or not used by OptiStruct are left blank.
Some values which would generate warning on the input will be printed after
adjustment.
Optional continuation cards may be printed even if they did not appear in the input.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

67

6.

The interpreted echo is always printed using a fixed field format (8 character fields)
except GRID and DMIG cards, which are printed using free format (comma separated
fields) with 10 decimal digits accuracy. Note that the use of IDs larger than 99,999,999
is allowed, but ECHO will not be usable in these cases as such IDs cannot be printed in
fixed format.
DMIG cards are usually very large and are not shown in the interpreted echo. Adding the
card:
OSDIAG,167,1
anywhere in the control section will force full printout of DMIG cards if the interpreted
echo is requested.

7.

{cardname} contains the list of all cards which are to be included in the interpreted echo
(or excluded, if EXCEPT keyword is present). This list may contain ELEM, MAT, or PROP
keywords, which is equivalent to listing all valid element, material, or property names,
respectively.

8.

Multiple ECHO cards are allowed; all parameters of these cards are accumulated in the
order in which they are input. EXCEPT may appear anywhere (for example, before or after
{cardname} list) and may be repeated on multiple cards.

9.

ECHOON / ECHOOFF cards may appear in any section of the input deck.

10. All comment cards, empty cards, and characters after the $ character on any card will
not be printed in any ECHO format.
11. The .echo file generated when 'ECHO = PUNCH' is defined represents a copy of the input
deck in a form suitable to use for another solution which, when used with the same
Subcase Information and I/O Options entries, should generate identical results (round off
error may be noticeable if the original input deck uses large field format). However, in
some cases, the ECHO may require manual editing before being acceptable as input for
OptiStruct. In particular, some optimization cards may be printed with information already
modified internally, and they will be not correct. Also some cards with a negative ID may
be printed in ECHO; those cards are automatically generated internally to OptiStruct, and
should simply be deleted.

68

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EDE
I/O Options and Subcase Information Entry
EDE - Output Request
Description
The EDE command can be used in the I/O Options or Subcase Information sections to request
element energy loss per cycle and element energy loss per cycle density output for all
subcases or individual subcases respectively.
Format
EDE (format_list, type, dmig) = option

Argument

Option

Description

format

<HM, H3D,
PUNCH, OP2,
PLOT, blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D format


(.h3d file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 8).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST is
defined in the bulk data section.

blank:

Results are output in all active formats


for which the result is available.

AVERAGE:

In frequency response analysis average


energy is output.

AMPLITUDE:

In frequency response analysis the


amplitude of energy is output.

PEAK:

In frequency response analysis the


peak energy is output. This is the sum
of AVERAGE and AMPLITUDE.

Default = blank

type

<AVERAGE,
AMPLITUDE,
PEAK>
Default =
AVERAGE
see Comment 7

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

69

Argument

Option

Description

dmig

<DMIG, NODMIG>

DMIG:

Results are provided for external


superelements in the .out file.

NODMIG:

Results are not provided for external


superelements in the .out file.

YES, ALL,
blank:

Element damping energy and damping


energy density are output for all
elements.

NO, NONE:

Element damping energy and damping


energy density are not output.

SID:

If a set ID is given, element damping


energy and damping energy density are
output only for elements listed in that
set.

Default =
NODMIG

option

<YES, ALL, NO,


NONE, SID>
Default = ALL

Comments
1.

When an EDE command is not present, element damping energy and damping energy
density is not output.

2.

Initial thermal strain is included in the calculation of element energy loss per cycle and
element energy loss per cycle density.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

6.

Type only applies to frequency response analysis.

7.

There are three ways to calculate the Element Damping Energy in Frequency Response
Analysis. They are listed as follows:

70

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type of Output

Formula

Average

Amplitude

Peak
Where,
E = Elemental Energy
{Ur } = Displacement (Real Part)
{Ui } = Displacement (Imaginary Part)
[Be ] = Elemental Damping
8.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

71

EIGVNAME
I/O Options Entry
EIGVNAME - Filename Prefix Definition
Description
The EIGVNAME command can be used in the I/O Options section to define the prefix to be
used for external eigenvalue data files (.eigv).
Format
EIGVNAME = prefix

Argument

Description

prefix

The prefix to be used for the saving and retrieval of external eigenvalue
data files.
The external eigenvalue data file name is of the form <prefix>_#.eigv,
where <prefix> is defined here, # is the integer argument of the
EIGVSAVE subcase information entry or one of the integer arguments of
the EIGVRETRIEVE subcase information entry.

Comments
1.

When an EIGVNAME command is not present, the OUTFILE prefix definition is used. If
OUTFILE is not defined, the prefix of the input file is used.

2.

Only one occurrence of EIGVNAME is permitted.

3.

EIGVNAME must appear before the first subcase.

4.

The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

5.

Prefixes specified on the EIGVNAME card can be arbitrary file prefixes with optional paths
appropriate to the operating system (Windows or UNIX). They may be enclosed in quotes
(double or single quotes can be used), and either forward slash (/) or back slash (\)
characters can be used to separate parts of the path name.
OptiStruct uses the following rules for the EIGVNAME card:
When the argument contains an absolute path of the file (if it starts with "/" on UNIX
or a drive letter, such as "D:", on Windows, for example), OptiStruct creates .eigv
files at the given location.

72

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

When only the file prefix is given (without the path), .eigv files will be created in the
current directory, meaning the directory from which OptiStruct has been executed, and
NOT in the directory where the input file is located.
When the argument contains a relative path (../filename or sub/filename, for
example), .eigv files will be created in a directory relative to where OptiStruct is
executed and NOT relative to the directory where the input file is located.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

73

EKE
I/O Options and Subcase Information Entry
EKE - Output Request
Description
The EKE command can be used in the I/O Options or Subcase Information sections to request
kinetic energy and kinetic energy density output for all subcases or individual subcases
respectively.
Format
EKE (format_list, type, dmig, peakoutput) = option

Argument

Option

Description

format

<HM, H3D,
PUNCH, OP2,
PLOT, blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D format


(.h3d file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 8).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST is
defined in the bulk data section.

blank:

Results are output in all active formats


for which the result is available.

<AVERAGE,
AMPLITUDE,
PEAK>

AVERAGE:

In frequency response analysis average


energy is output.

Default =
AVERAGE

AMPLITUDE:

In frequency response analysis the


amplitude of energy is output.

PEAK:

In frequency response analysis the


peak energy is output. This is the sum
of AVERAGE and AMPLITUDE.

Default = blank

type

see Comment 7

74

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Option

Description

dmig

<DMIG,
NODMIG>

DMIG:

Results are provided for external


superelements in the .out file.

Default =
NODMIG

NODMIG:

Results are not provided for external


superelements in the .out file.

<PEAKOUT>

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will
be considered for this output.

peakoutput

Default = blank

option

<YES, ALL, NO, YES, ALL,


NONE, SID>
blank:

Element kinetic energy and kinetic


energy density are output for all
elements.

Default = ALL
NO, NONE:

Element kinetic energy and kinetic


energy density are not output.

SID:

If a set ID is given, element kinetic


energy and kinetic energy density are
output only for elements listed in that
set.

Comments
1.

When an EKE command is not present, element kinetic energy and kinetic energy density
is not output.

2.

Initial thermal strain is included in the calculation of kinetic energy and kinetic energy
density.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

75

6.

Type only applies to frequency response analysis.

7.

There are three ways to calculate the Element Kinetic Energy in Frequency Response
Analysis. They are listed as follows:
Type of Output

Formula

Average

Amplitude

Peak
Where,
E = Element Energy
{vr } = Real part of Velocity
{vi } = Imaginary part of Velocity
[Me] = Element Mass
8.

76

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ENERGY
I/O Options and Subcase Information Entry
ENERGY - Output Request for Geometric Nonlinear Analysis Subcase
Description
The ENERGY command can be used in the I/O Options or Subcase Information sections to
request energy output for all geometric nonlinear analysis subcases or individual geometric
nonlinear analysis subcases respectively.
Format
ENERGY (format, type) = option

Argument

Option

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D format


(.h3d file).

blank:

Results are output in all active formats


for which the result is available.

ALL:

All energy results are output.

ENERG:

All energy results without hourglass


energy are output.

HOURG:

Hourglass energy only is output.

Default = blank

type

<ALL, ENERG,
HOURG>
Default = ALL

option

<YES, ALL, NO, YES, ALL,


NONE, SID,
blank:
PSID>

Energy results are output for all


elements.

Default = ALL

NO, NONE:

Energy results are not output.

SID:

If a set ID is given, energy results are


output only for elements listed in that
set.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

77

Argument

Option

Description
PSID:

If a property set ID is given, energy


results for the elements referencing
properties listed in the property set are
output.

Comments
1.

ENERGY is only applicable for geometric nonlinear analysis subcases which are defined by
an ANALYSIS = NLGEOM, IMPDYN or EXPDYN subcase entry. It is ignored for all other
subcases.

2.

Only formats that have been activated by an OUTPUT or FORMAT statement are valid for
use on this card.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

78

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ERP
I/O Options and Subcase Information Entry
ERP - Output Request
Description
The ERP command can be used in the I/O Options or Subcase Information sections to request
equivalent radiated power output for all subcases or individual subcases, respectively.
Format
ERP (format_list, grid) = option

Argument

Option

Description

format

<H3D, PUNCH,
blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

PUNCH:

Results are output in Nastran punch results


format (.pch file).

blank:

Results are output in all active formats for


which the result is available.

GRID:

Output the contribution of each grid in


addition to the ERP results for the PANEL,
defined by ERPPNL or PANELG (TYPE=ERP).
This is a normal velocity squared for each
grid specified in the panel definition.

Default = blank

grid

<GRID>
Default = blank

option

<YES, ALL, NO,


NONE>
Default = ALL

YES, ALL, Equivalent radiated power is output for all


panels.
blank:
NO, NONE: Equivalent radiated power is not output.

Comments
1.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

79

2.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

3.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as
it does not allow different frequencies for different formats.

4.

In addition to the ERP values, the following results are output to the .pch file: total ERP
over the loading frequencies, fraction of the total ERP at each loading frequency, and ERP
expressed in decibels ERBdB = 10 * log 10 (ERP) at each loading frequency.

5.

The ERP is calculated as half the normal velocity squared of each grid multiplied by the
associated area of each grid on the panel. The parameters for the speed of sound
(ERPC), fluid density (ERPRHO), and radiation loss factor (ERPRLF) are used in the
calculation of ERP using the formula below.

6.

The calculation of ERP in decibels (dB) is performed using the PARAM data RHOCP and
ERPREFDB in the equation below. ERPREFDB is the reference value in dB and RHOCP is the
scale factor:

7.

At least one of the bulk data entries ERPPNL or PANELG (TYPE=ERP) needs to be
specified, if the ERP Output Request is used.

80

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ESE
I/O Options and Subcase Information Entry
ESE - Output Request
Description
The ESE command can be used in the I/O Options or Subcase Information sections to request
strain energy and strain energy density output for all subcases or individual subcases
respectively.
Format
ESE (format_list, type, dmig, peakoutput) = option

Argument

Option

Description

format

<HM, H3D,
PUNCH, OP2,
PLOT, blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D format


(.h3d file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 8).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST
is defined in the bulk data section.

blank:

Results are output in all active formats


for which the result is available.

AVERAGE:

In frequency response analysis average


energy is output.

AMPLITUDE:

In frequency response analysis the


amplitude of energy is output.

PEAK:

In frequency response analysis the


peak energy is output. This is the sum
of AVERAGE and AMPLITUDE.

Default = blank

type

<AVERAGE,
AMPLITUDE,
PEAK>
Default =
AVERAGE
See Comment 7

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

81

Argument

Option

Description

dmig

<DMIG, NODMIG>

DMIG:

Results are provided for external


superelements in the .out file.

NODMIG:

Results are not provided for external


superelements in the .out file.

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will
be considered for this output.

YES, ALL,
blank:

Element strain energy and strain


energy density are output for all
elements.

NO, NONE:

Element strain energy and strain


energy density are not output.

SID:

If a set ID is given, element strain


energy and strain energy density are
output only for elements listed in that
set.

Default =
NODMIG

peakoutput <PEAKOUT>
Default = blank

option

<YES, ALL, NO,


NONE, SID>
Default = ALL

Comments
1.

When an ESE command is not present, element strain energy and strain energy density is
not output.

2.

Initial thermal strain is included in the calculation of strain energy and strain energy
density.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

82

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

Type only applies to frequency response analysis.

7.

There are three ways to calculate the Element Strain Energy in Frequency Response
Analysis. They are listed as follows:
Type of Output

Formula

Average

Amplitude

Peak
Where,
E = Elemental Energy
{u r } = Displacement (Real Part)
{u i } = Displacement (Imaginary Part)
[Ke] = Elemental Stiffness
8.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

83

FLUX
I/O Options and Subcase Information Entry
FLUX Output Request
Description
The FLUX command can be used in the I/O Options or Subcase Information sections to
request temperature gradient and flux output for all steady-state heat transfer analysis
subcases, transient heat transfer analysis subcases or individual heat transfer analysis
subcases, respectively.
Format
FLUX (format_list) = option

Argument

Options

Description

format

<PUNCH, OP2,
H3D, PLOT,
blank>

PUNCH:

Results are output in Nastran punch results


format (.pch file).

OP2:

Results are output in Nastran output2 format


(.op2 file) (see comment 5).

PLOT:

Results are output in Nastran output2 format


(.op2 file) when PARAM, POST is defined in the
bulk data section.

H3D:

Results are output in Hyper3D format (.h3d file).

blank:

Results are output in all active formats for


which the result is available.

<YES, ALL, NO,


NONE, SID>

YES, ALL,
blank:

Flux results are output for all valid elements.

Default = ALL

NO, NONE:

Flux results are not output.

SID:

If a set ID is given, flux results are output only


for elements referenced by that set.

Default = blank

option

84

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

When the FLUX command is not present, flux results are not output.

2.

Flux output is only available for steady-state heat transfer analysis and transient heat
transfer analysis solution sequences.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
the results available and their respective formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

85

FORCE/ELFORCE
I/O Options and Subcase Information Entry
FORCE - Output Request
Description
The FORCE command can be used in the I/O Options or Subcase Information sections to
request element force output for all subcases or individual subcases respectively.
Format
FORCE (sorting, format_list, form, type, location, random, peakoutput, modal)
= option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH


format (.pch file) or the OUTPUT2 format (.op2
file) output for normal modes, frequency
response, and transient subcases. It will be
ignored without warning if used elsewhere.

Default = blank

format

<HM, H3D, OPTI,


PUNCH, OP2, PLOT,
blank>

SORT1:

Results for each frequency/


timestep are grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment
8).

blank:

For frequency response analysis,


if no element SET is specified,
SORT1 is used, otherwise, SORT2
is used; for transient analysis,
SORT2 is used.

HM:

Results are output in HyperMesh


result format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in OptiStruct


results format (.force file).

Default = blank

86

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
PUNCH:

Results are output in Nastran


punch results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 11).

PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the
bulk data section.
If PARAM, POST is not defined in
the bulk data section, this format
allows the form for complex
results to be defined for XYPUNCH
output without having other
output.

blank:

form

<COMPLEX, REAL,
IMAG, PHASE,
BOTH>
Default (HM only) =
COMPLEX

COMPLEX (HM Provides a combined magnitude/


only), blank: phase form of complex output to
the .res file for the HM output
format.
REAL, IMAG:

Provides rectangular format (real


and imaginary) of complex
output.

PHASE:

Provides polar format (phase and


magnitude) of complex output.

BOTH (HM
only):

Provides both rectangular and


polar formats of complex output.

TENSOR:

Force results are output for all


solution sequences in which force
results are supported. The Tensor

Default (all other


formats) = REAL

type

<TENSOR, DIRECT>
Default = TENSOR

Altair Engineering

Results are output in all active


formats for which the result is
available.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

87

Argument

Options

Description
format is used for H3D output
(See comment 9).

location

<CENTER, CUBIC,
SGAGE, CORNER,
BILIN>
Default = CENTER

random

<PSDF, RMS>

DIRECT:

Force results are output for all


solution sequences in which force
results are supported. The Direct
format is used for H3D output
(See comment 9).

CENTER:

Element forces for shell and solid


elements are output at the
element center only.

CUBIC:

Element forces for shell elements


are output at the element center
and grid points using the strain
gage approach with cubic bending
correction.

SGAGE:

Element forces for shell elements


are output at the element center
and grid points using the strain
gage approach.

CORNER or
BILIN:

Element forces for shell elements


are output at the element center
and at the grid points using
bilinear extrapolation.

PSDF:

Requests PSD and RMS results


from random response analysis to
be output for CBUSH elements
only.

No default

Only valid for H3D format. The


"RMS over Frequencies" output is
at the end of the Random results
in the .h3d file.
RMS:

88

Requests only the RMS over


Frequencies result from random
response analysis to be output
for CBUSH elements only.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
Valid only for the H3D format.

peakoutput

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the
PEAKOUT card will be considered
for this output.

MODAL:

If MODAL is present, element


forces of the structural modes
and residual vectors are output
to the PUNCH and OUTPUT2 files
for modal frequency response and
transient analysis.

<YES, ALL, NO,


NONE, SID>

YES, ALL,
blank:

Element force is output for all


valid elements.

Default = ALL

NO, NONE:

Force is not output.

SID:

If a set ID is given, force is


output only for valid elements
listed in that set.

<PEAKOUT>
Default = blank

modal

<MODAL>
Default = blank

option

Comments
1.

When neither FORCE nor ELFORCE commands are present, force is not output.

2.

FORCE results are available for ELAS (CELAS1, CELAS2, CELAS3, CELAS4), ROD (CROD),
BAR (CBAR, CBEAM), BUSH (CBUSH), PLATE (CQUAD, CTRIA), GAP (CGAP), FASTENER
(CFAST)*, VISCOUS DAMPER (CVISC), SCALAR DAMPER (CDAMP1, CDAMP2, CDAMP3,
CDAMP4) and WELD (CWELD) elements.
*

CFAST elements or their corresponding force results are available for post-processing in
HyperView only if the .fem file is loaded as a model (procedure used in comment 9).

3.

The form argument is only applicable for frequency response analysis. It is ignored in
other instances.

4.

The forms BOTH and COMPLEX do not apply to the .frf output files.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

89

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information
on which results are available in which formats.

6.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

7.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

8.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

9.

Vector and Tensor plots of some element force results (weld, beam/bar and gap
elements) are available for post-processing in HyperView only if the .fem file is loaded in
the Load Model field and the results file is loaded in the Load Results field (below is an
example illustration of the HyperView Load model and results: panel).
Make sure that the Advanced option is selected from the Result Math Template: menu.

10. For shell elements force results are given as force/unit length.
11. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

90

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FORMAT
I/O Options Entry
FORMAT - Output Control
Description
The FORMAT command can be used in the I/O Options section to indicate the format in which
results are to be output.
Format
FORMAT = option

Argument Options

Description

option

OPTI, OS, ASCII:

OptiStruct ASCII results


files are output.

HM, HYPER:

The HyperMesh binary


results file (.res file) is
output.

BOTH:

Same as defining both HM


and OPTI.

H3D:

Hyper3D binary results file


(.h3d file) and an HTML
report (.html file) are
output.

FLX:

Same as defining both HM


and H3D.

NASTRAN, PUNCH:

The Nastran punch file


format (.pch file) is
output.

PATRAN, PATRAN:

A number of Patran ASCII


results files are output.
APATRAN outputs the
same files using an
alternative file naming
convention.

O2, OUT2, OP2:

Nastran binary output2 file


format (.op2 file) is output

<ASCII, OS, OPTI,


HM, HYPER, BOTH,
H3D, FLX, NASTRAN,
PUNCH, PATRAN,
APATRAN, O2,
OUT2, OP2, PLOT,
NONE>
Default = FLX

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

91

Argument Options

Description
(see comment 4).
PLOT:

Results are output in


Nastran output2 format
(.op2 file) when PARAM,
POST is defined in the bulk
data section.

NONE:

Analysis output is not


required. Cannot be used
in combination with other
FORMAT commands.

Comments
1.

Information provided on OUTPUT entries takes precedence over information provided on


FORMAT entries. If neither of these entries are defined, the output formats defined in the
OptiStruct Configuration File are used. If no format is defined by the OptiStruct
configuration file, then both the HM and H3D formats are active by default.

2.

Multiple FORMAT commands are allowed.

3.

It is recommended to use the OUTPUT command instead of the FORMAT command since it is
more flexible and allows different frequencies of output for different formats during an
optimization.

4.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

92

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FOS
I/O Options and Subcase Information Entry
FOS Output Request
Description
The FOS command can be used in the I/O Options or Subcase Information sections to request
fatigue factor of safety output for all fatigue subcases or individual fatigue subcases.
Format
FOS (format_list) = option

Argument

Options

Description

format

<H3D,OPTI, blank> H3D:


Default = blank

option

<YES,ALL,NO,
NONE,SID,PSID>
Default = ALL

Results are output in Hyper3D format (.h3d


file).

OPTI:

Results are output in OptiStruct results format


(.fat file).

blank:

Results are output in all active formats for


which the result is available.

YES,ALL, Results are output for all elements.


blank:
NO,NONE: Results are not output.
SID:

If a set ID is provided, results are output only


for elements listed in that set.

Comments
1.

When a FOS command is not present, fatigue FOS results are not output.

2.

Multiple formats are allowed on the same entry; these should separated by a comma. If
no format is specified, then this output control applies to all formats defined by OUTPUT
or FORMAT commands, for which the result is available. See Results Output by OptiStruct
for information on which results are available, in which formats.

3.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

93

GPFORCE
I/O Options and Subcase Information Entry
GPFORCE - Output Request
Description
The GPFORCE command can be used in the I/O Options or Subcase Information sections to
request grid point force balance output for all subcases or individual subcases respectively.
Format
GPFORCE (format_list, elem, form, peakoutput, modal) = option

Argument

Options

Description

format

<H3D, OPTI,
PUNCH, OP2,
PLOT, blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

OPTI:

Results are output in OptiStruct results


format (.gpf file).

PUNCH:

Results are output in Nastran punch results


format (.pch file).

OP2:

Results are output in Nastran output2 format


(.op2 file) (see comment 9).

PLOT:

Results are output in Nastran output2 format


(.op2 file) when PARAM, POST is defined in
the bulk data section.

NOELEM:

GPFORCE results in the H3D output file will


not include element contributions. However,
the TOTAL value for each GRID includes the
element contributions.

ELEM:

GPFORCE results in the H3D output file


includes element contributions.

REAL, IMAG:

Provides rectangular format (real and


imaginary) of complex output.

Default = blank

elem
(H3D only)

<ELEM,
NOELEM>
Default =
NOELEM

form

94

<REAL, IMAG,
PHASE>

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

Default = REAL

PHASE:

Provides polar format (phase and magnitude)


of complex output.

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will be
considered for this output.

MODAL:

If MODAL is present, grid point forces of the


structural modes and residual vectors are
output to the PUNCH and OUTPUT2 files for
modal frequency response and transient
analysis.

peakoutput <PEAKOUT>
Default = blank

modal

<MODAL>
Default = blank

option

<YES, ALL, NO, YES, ALL,


NONE, SID>
blank:
Default = ALL

Grid point force balance is output for all


elements.

NO, NONE:

Grid point force balance is not output.

SID:

If a set ID is given, grid point force balance


is output only for nodes listed in that set.

Comments
1.

When a GPFORCE command is not present, grid point force balance is not output.

2.

GPFORCE output is available for the following solution sequences:


Solution Sequences

Output Formats

Static Analysis

H3D, OP2, PCH, OPT

Normal Modes Analysis

H3D, OP2, PCH

Direct Frequency Response Analysis

H3D, OP2, PCH, OPT

Modal Frequency Response Analysis

H3D, OP2, PCH, OPT

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

95

3.

The form argument is only applicable for frequency response analysis. It is ignored in
other instances.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

7.

GPFORCE in .op2 output can only be post-processed with the Free Body Diagram (FBD)
tools in HyperMesh.

8.

GPFORCE in .h3d output is specifically added for the load transfer path analysis with
NVDirector. It is only available for linear static, frequency response, and acoustic
analyses.

9.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

96

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GPKE
I/O Options and Subcase Information Entry
GPKE - Output Request for Grid Point Kinetic Energy
Description
The GPKE command can be used in the I/O Options or Subcase Information sections to
request grid point kinetic energy output for normal modes subcases.
Format
GPKE (format_list) = option

Argument

Options

Description

format

<PUNCH, blank>

PUNCH:

Default = blank
option

Results are output in Nastran punch results


format (.pch file).

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank: GPKE results are output for all elements.

Default = ALL

NO, NONE:

GPKEs results are not output.

SID:

If a set ID is given, GPKE results are output


only for grids listed in that set.

Comments
1.

Grid point kinetic energy is written in % of the total kinetic energy of all grids in the
structure. Therefore, GPKE results for each grid are the same regardless of the requested
option (ALL, YES, or SID).

2.

Note that if the coupled mass matrix is used (PARAM,COUPMASS,YES), then the results at
each GRID are influenced by all GRID connected to that GRID. Using a diagonal mass
matrix formulation (PARAM,COUPMASS,NO) provides more meaningful results.

3.

For large problems solved using EIGRA, run times increase if GPKE=ALL or a coupled mass
matrix (PARAM,COUPMASS,YES) is specified, as the entire eigenvector for each mode
must be calculated and stored.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

97

GPSTRESS/GSTRESS
I/O Options and Subcase Information Entry
GPSTRESS - Output Request
Description
The GPSTRESS command can be used in the I/O Options or Subcase Information sections to
request grid point stresses output for all subcases or individual subcases respectively.
Format
GPSTRESS (format_list, averaging, type) = option

Argument

Options

Description

format

<HM, H3D, PUNCH,


OP2, blank>

HM:

Results are output in


HyperMesh results format
(.res file).

H3D:

Results are output in


Hyper3D format (.h3d file).

PUNCH:

Results are output in


Nastran punch format (.pch
file).

OP2:

Results are output in


Nastran output2 format
(.op2 file) (see comment 8).

blank:

Results are output in all


active formats for which the
result is available.

GLOBAL:

Only the globally averaged


GPSTRESS results are output.

BYPROP, blank:

Both the globally averaged


GPSTRESS results and the
GPSTRESS results averaged
by property for each
property are output.

Default = blank

averaging

<GLOBAL, BYPROP>
Default = BYPROP

98

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

type

<VON, PRINC, MAXS,


SHEAR, ALL,
TENSOR, DIRECT>

VON:

Only von Mises Stress


results are output.

PRINC, MAXS,
SHEAR:

The von Mises and maximum


principal stress results are
output.

ALL, blank:

All stress results are


output.

TENSOR:

All stress results are output.


Tensor format is used for
H3D output.

DIRECT:

All stress results are output.


Direct format is used for
H3D output.

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank:

Grid point stresses output


for all elements.

Default = ALL

NO, NONE:

Grid point stresses are not


output.

SID:

If a set ID is given, grid


point stresses are output
only for nodes listed in that
set.

Default = ALL

option

Comments
1.

When a GPSTRESS command is not present, grid point stresses are not output.

2.

Grid point stresses are only available for solid elements.

3.

Grid point stresses are not available for elements which form part of a topology design
space. When an analysis only run is performed, grid point stresses are available for all
solid elements. When PARAM, REANAL is used, grid point stress contributions are only
calculated for fully dense elements.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

99

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

7.

Grid point stresses are output for the entire model and for each individual PSOLID
component. This allows grid point stresses to be accurately obtained at the interface of
two components referencing different material definitions.

8.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

100

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

HISOUT
I/O Options Entry
HISOUT - Output Control
Description
The HISOUT command can be used in the I/O Options section to control the amount of data
printed to the .hgdata file.
Format
HISOUT = option

Argument

Options

Description

option

<Integer <32> HISOUT value is equal to the sum of the desired options:
Default = 31

1: Design variable.
2: Objective function and maximum percent constraint
violation.
4: All non-stress responses.
8: All DRESP2 responses.
16: All DRESP3 responses.
If blank: no output to .hgdata file.
Example:
If you wanted design variables and all DRESP2 responses,
you would enter:
HISOUT = 9

Comments
1.

When a HISOUT command is not present, a value of 31 is assumed.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

101

HYBDAMP
I/O Options Entry
HYBDAMP Apply Hybrid Damping to the Residual Structure in a Direct or Transient
Frequency Response Analysis
Description
The HYBDAMP command can be used in the I/O Options section to request modal damping as a
function of the natural frequency of the model in Dynamic Analysis.
Format
HYBDAMP = option

Argument

Option

Description

option

< SID >

SID: Set identification of HYBDAMP in bulk data entry.

No default
Comments
1.

102

HYBDAMP can be set at the global level in the I/O Options section. It can exist only once
in the I/O Options section.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

INCLUDE
I/O Options and Bulk Data Entry
INCLUDE - File Selection
Description
The INCLUDE command can be used in the I/O Options, Subcase Information, or Bulk Data
sections to indicate that the contents of another file are to be inserted into the input file at
the exact location of the include command.
Format
INCLUDE option

Argument

Options

Description

option

<filename>

filename: the path to and the name of the file to be


included.

No default
Comments
1.

INCLUDE commands may be placed at any location in the input file, but must include
information appropriate to that location.

2.

Names specified on the INCLUDE card can be arbitrary file names with optional paths
appropriate to the operating system (Windows or UNIX). They may be enclosed in quotes
(double or single quotes can be used), and either forward slash (/) or back slash (\)
characters can be used to separate parts of the path name.
The following rules are used to locate a file referenced on the INCLUDE card:
When the argument contains the absolute path of the file (if it starts with "/" on UNIX
or a drive letter, such as "D:", on Windows, for example), the file at the given location
is used.
When only the file prefix is given (without the path), the file has to be located in the
same directory as the file containing the INCLUDE command.
When the argument contains a relative path (../filename or sub/filename, for
example), it is located in the directory relative to the file containing the INCLUDE
command and is NOT relative to the directory in which the solver was executed, or to
the directory where the main file is located.

3.

The INCLUDE command supports path names of up to 200 characters in length. This data
can be on a single line or span multiple continuation lines. See Guidelines for I/O Options
and Subcase Information Entries for an example showing how to enter long file names on
multiple lines.

4.

Represented through the master model in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

103

LIFE
I/O Options and Subcase Information Entry
LIFE Output Request
Description
The LIFE command can be used in the I/O Options or Subcase Information sections to
request output of fatigue life results for all fatigue subcases or individual fatigue subcases
respectively.
Format
LIFE (format_list) = option

Argument

Options

Description

format

<H3D, OPTI, blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

OPTI:

Results are output in OptiStruct results


format (.fat file).

blank:

Results are output in all active formats for


which the result is available.

YES, ALL,
blank:

Results are output for all elements.

NO, NONE:

Results are not output.

SID:

If a set ID is given, results are output only


for elements listed in that set.

Default = blank

option

<YES, ALL, NO,


NONE, SID>
Default = ALL

Comments
1.

When a LIFE command is not present, fatigue life results are not output.

2.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output by OptiStruct for
information on which results are available in which formats.

3.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

104

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

LOADLIB
I/O Options Entry
LOADLIB - External Library and File Reference
Description
The LOADLIB entry can be used in the I/O Options section to define the external libraries and
external files to be loaded into OptiStruct. External functions can be implemented within
dynamic libraries (.dll) under Windows, shared libraries (.so) under Linux, by using
HyperMath (.hml) on Windows and Linux, and external files by using Microsoft Excel (.xls or
.xlsx) on Windows.
Format
LOADLIB = type, group, path

Argument

Options

Description

type

<DRESP3>

TYPE identifier that defines the type of library(or


file) to be loaded into OptiStruct. Currently only
one type implemented - DRESP3.

No default
group

<Character string>

GROUP identifier that is referenced by a DRESP3


bulk data entry.

No default
path

<Path including file


name and extension>

The path to the external shared or dynamic


library to be loaded.

No default
Comments
1.

Absolute paths (those starting with a drive letter or a slash) will be used as they are
defined on the LOADLIB card. Relative library or file paths will be appended to the path
corresponding to the input deck's location.

2.

The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

105

MBFORCE
I/O Options Entry
MBFORCE Output Control
Description
The MBFORCE command can be used in the I/O Options section to request force output for a
set of joints and/or force elements from multi-body dynamics subcases.
Format
MBFORCE = option

Argument

Options

Description

option

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank: Force is output for all joints and


force elements.

Default = ALL

NO, NONE: Forces are not output.


SID: If a set ID is given, forces are output only
for joints and force elements listed in that set.
Note: Joints and force elements may share IDs.
When MBFORCE is requested for a SET,
force results are output for all entities
whose ID is part of the SET definition.

Comments
1.

When MBFORCE is not present, force results for joints and force elements are not output.

2.

The force results for selected joints and force elements are output to the .mrf file.

106

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MECHCHECK
I/O Options Entry
MECHCHECK - Massless Mechanism Check
Description
The MECHCHECK command can be used in the I/O options section to perform a massless
mechanism check on the model.
Format
MECHCHECK
Comments
1.

Running the normal mode analysis by adding MECHCHECK helps detect the massless
mechanism where the massless mechanism shows up as rigid body modes.

2.

A massless mechanism occurs due to degrees of freedom that do not possess both
stiffness and mass. To find such degrees of freedom, a small amount of mass is added to
the mass matrix so that the massless mechanism shows up as a rigid body mode (the
stiffness matrix K is still zero but the mass matrix M becomes non-zero) in normal modes
analysis. This is the reason why you have to set the lower bound on the EIGRL bulk data
entry to blank or zero when MECHCHECK is used.

3.

The analysis results with this card cannot be used since the model is changed internally.
It can only be used to find the massless mechanism. The message RESULTS FROM THIS
SOLVER RUN ARE INACCURATE AS IT IS IN MECHCHECK MODE is also displayed in the .out
file when MECHCHECK is included in the I/O Options section of the solver deck.

4.

MECHCHECK results (in the .out file) include a list of rigid body modes in the following
format:

ANALYSIS RESULTS:
-----------------ITERATION

Rigid Modes in Eigenvalue Loadcase:

----------------------------------------------------Mode

Grid No. Type

x-comp

y-comp

z-comp

----------------------------------------------------1

##

Tran

##

###

###

##

Rotn

##

###

###

etc

-----------------------------------------------------

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

107

MODALDE
I/O Options Entry
MODALDE Output Request
Description
The MODALDE command can be used above the first SUBCASE or within a SUBCASE definition
to request modal damping energy (the energy loss per cycle) output for all subcases or
individual subcases respectively. Note that this modal damping energy only includes the
energy contribution from viscous dampers. Structural damping and modal damping are not
included.
Format
MODALDE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=typ
e) = option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

blank:

Results are output in all active formats for


which the result is available.

Default = blank

thresh

<Real>

Specifies an absolute threshold under which results should


not be output.

No default

rthresh

topn

No default

Specifies a relative threshold under which results should


not be output. This value is relative to the corresponding
total modal energy.

<Integer>

Specifies that only the top N values should be output.

<Real>

No default

type

108

<AVERAGE,
AMPLITUDE, PEAK>

AVERAGE:

The average of the energy is output.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

mset

option

Options

Description

Default = AVERAGE

AMPLITUDE:

The amplitude of the energy is output.

PEAK:

The peak energy is output. This is the sum


of AVERAGE and AMPLITUDE.

<ALL, SID,
TOTAL>

ALL:

Modal energy is output for all modes.

Default = ALL

SID:

If a set ID is given, modal energy is output


only for modes listed in that set.

TOTAL:

Only the total energy is output.

YES, ALL,
blank:

Modal energy is output for all modes.

NO, NONE:

Modal energy is not output.

<YES, ALL, NO,


NONE>
Default = ALL

Comments
1.

When MODALDE command is not present, modal damping energy is not output.

2.

Modal damping energy output is only available for modal frequency response analysis.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

6.

Note that this modal damping energy only includes the energy contribution from viscous
dampers. Structural damping and modal damping are not included.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

109

MODALKE
I/O Options Entry
MODALKE Output Request
Description
The MODALKE command can be used above the first SUBCASE or within a SUBCASE definition
to request modal kinetic energy output for all subcases or individual subcases respectively.
Format
MODALKE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=typ
e) = option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

blank:

Results are output in all active formats for


which the result is available.

Default = blank

thresh

<Real>

Specifies an absolute threshold under which results should


not be output.

No default

rthresh

topn

No default

Specifies a relative threshold under which results should


not be output. This value is relative to the corresponding
total modal energy.

<Integer>

Specifies that only the top N values should be output.

<Real>

No default

type

110

<AVERAGE,
AMPLITUDE, PEAK>

AVERAGE:

The average of the energy is output.

Default = AVERAGE

AMPLITUDE:

The amplitude of the energy is output.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

mset

option

Options

Description
PEAK:

The peak energy is output. This is the sum


of AVERAGE and AMPLITUDE.

<ALL, SID,
TOTAL>

ALL:

Modal energy is output for all modes.

Default = ALL

SID:

If a set ID is given, modal energy is output


only for modes listed in that set.

TOTAL:

Only the total energy is output.

YES, ALL,
blank:

Modal energy is output.

NO, NONE:

Modal energy is not output.

<YES, ALL, NO,


NONE>
Default = ALL

Comments
1.

When MODALKE command is not present, modal kinetic energy is not output.

2.

Modal kinetic energy output is only available for modal frequency response analysis.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

111

MODALSE
I/O Options Entry
MODALSE Output Request
Description
The MODALSE command can be used above the first SUBCASE or within a SUBCASE definition
to request modal strain energy output for all subcases or individual subcases respectively.
Format
MODALSE(format_list,THRESH=thresh,RTHRESH=rthresh,TOP=topn,MODES=mset,TYPE=typ
e) = option

Argument

Options

Description

format

<H3D, blank>

H3D:

Results are output in Hyper3D format (.h3d


file).

blank:

Results are output in all active formats for


which the result is available.

Default = blank

thresh

<Real>
No default

rthresh

topn

<Real>

Specifies an absolute threshold under which results should


not be output.

No default

Specifies a relative threshold under which results should


not be output. This value is relative to the corresponding
total modal energy.

<Integer>

Specifies that only the top N values should be output.

No default

type

112

<AVERAGE,
AVERAGE:
AMPLITUDE, PEAK>
AMPLITUDE:
Default = AVERAGE

The average of the energy is output.


The amplitude of the energy is output.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

mset

Options

Description
PEAK:

The peak energy is output. This is the


sum of AVERAGE and AMPLITUDE.

ALL:

Modal energy is output for all modes.

SID:

If a set ID is given, modal energy is output


only for modes listed in that set.

TOTAL:

Only the total energy is output.

<YES, ALL, NO,


NONE>

YES, ALL,
blank:

Modal energy is output.

Default = ALL

NO, NONE:

Modal energy is not output.

<ALL, SID,
TOTAL>
Default = ALL

option

Comments
1.

When MODALSE command is not present, modal strain energy is not output.

2.

Modal strain energy output is only available for modal frequency response analysis.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

5.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

113

MODEL
I/O Options Entry
MODEL - Output Control
Description
The MODEL command can be used in the I/O Options section to request output of only a
subset of the model and related results for H3D and OUTPUT results files as well as for CMS
superelements.
Format
MODEL = elset, gridset, rigidset

Argument Options

Description

elset

SID:

<SID, PLOTEL,
ALL, NONE>
Default
(analysis run) =
ALL

PLOTEL:
Default (CMS SE
creation) =
NONE
ALL:

gridset

rigidset

ID of an element SET. A set of elements that


describe the subset of the model for which results
and model information is to be output. All GRID
and SPOINT associated with these elements will
also be output.
All PLOTELs in the model and their associated
GRID will be output.
All elements in the model and their associated
GRID will be output.

NONE:

No elements.

<SID, ALL,
NONE>

SID:

SID of a SET. A set of grids to be added to the


subset associated with the preceding elset field.

Default = NONE

ALL:

All grids.

NONE:

No grids are added to the subset described by


the preceding elset field.

RIGID/
ALL:

All rigid elements and their associated GRID will be


output.

<RIGID/ALL,
NORIGID/NONE,
SID>
Default
(analysis run)
=RIGID/ALL

114

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument Options

Description

Default (CMS SE
NORIGID/
creation) =
NONE:
NORIGID/NONE
SID:

No rigid elements will be output.

ID of a rigid element SET. A set of rigid elements


that describe the subset of the model for which
model information is to be output. All GRID and
SPOINT associated with these rigid elements will
also be output.

Comments
1.

For CMS superelements output in h3d format, only the ASET DOF are output when the
MODEL data is not present. When the MODEL data is present, the .h3d file contains the
ASET DOF and what is specified on the MODEL data.

2.

In addition to the results output, the MODEL data controls the portion of the model that is
written to the .op2 and .h3d files.

3.

When PARAM,EXCOUT with values of 0, 3, 4, 5 or 6 is used during CMS superelement


creation, the default is to output the entire model, as well as results to the .h3d file and
AVL/EXCITE files.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

115

MPCFORCE
I/O Options and Subcase Information Entry
MPCFORCE - Output Request
Description
The MPCFORCE command can be used in the I/O Options or Subcase Information sections to
request multi-point force of constraint vector is output for all subcases or individual subcases
respectively.
Format
MPCFORCE (sorting, format, form_list, peakoutput, modal) = option

Argument Options

Description

sorting

This argument only applies to the PUNCH format (.pch file) or


the OUTPUT2 format (.op2 file) output for normal modes,
frequency response, and transient subcases. It will be
ignored without warning if used elsewhere.

<SORT1, SORT2>
Default = blank

format

<OPTI, PUNCH,
OP2, PLOT,
blank>

SORT1:

Results for each frequency/timestep are grouped


together.

SORT2:

Results for each grid/element are grouped


together (See comment 5).

blank:

For frequency response analysis, if no grid SET is


specified, SORT1 is used, otherwise, SORT2 is
used; for transient analysis, SORT2 is used.

OPTI:

Results are output in OptiStruct results format


(.mpcf file).

PUNCH:

Results are output in Nastran punch results


format (.pch file).

OP2:

Results are output in Nastran otput2 format


(.op2 file) (see comment 6).

PLOT:

Results are output in Nastran output2 format


(.op2 file) when PARAM, POST is defined in the
bulk data section.

Default = blank

116

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument Options

form

Description

<REAL, IMAG,
PHASE>

blank:

Results are output in all active formats for which


the result is available.

REAL,
IMAG:

Provides rectangular format (real and imaginary)


of complex output.

PHASE:

Provides polar format (phase and magnitude) of


complex output.

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will be
considered for this output.

MODAL:

If MODAL is present, multi-point constraint


forces of the structural modes and residual
vectors are output to the PUNCH and OUTPUT2
files for modal frequency response and transient
analysis.

Default = REAL

peakoutpu
t

<PEAKOUT>
Default = blank

modal

<MODAL>
Default = blank

option

<YES, ALL, NO,


NONE, SID>

YES, ALL, Multi-point force of constraint vector is output


for all grids.
blank:

Default = ALL

NO, NONE:

Multi-point force of constraint vector is not


output.

SID:

If a set ID is given, multi-point force of


constraint vector is output only for grids listed in
that set.

Comments
1.

When an MPCFORCE command is not present, multi-point force of constraint vector is not
output.

2.

Multiple formats area allowed on the same entry; these should be comma separated. If
no format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

117

3.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

4.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were use; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

5.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

6.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

118

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MSGLMT
I/O Options and Subcase Information Entry
MSGLMT - Output Control
Description
The MSGLMT command can be used in the I/O Options section to limit the number of ERROR,
WARNING and INFORMATION messages output, or to elevate a WARNING or INFORMATION
message to an ERROR.
Format
MSGLMT (type) = value
MSGLMT, type, value
MSGLMT, mode
Examples
MSGLMT (WARNING) = 1000
MSGLMT (101) = 50

Argument

Options

Description

type

<ERROR,
WARNING, ID>

ERROR:

Limits the total number of ERROR


messages allowed to the value
provided. Once this limit is reached,
the run terminates.

WARNING:

Limits the total number of WARNING and


INFORMATION messages reported in
the .out file to the value provided.

ID:

Limits the number of instances of a


message with the given ID reported in
the .out file to the value provided.

INTEGER:

If a positive integer is given, the limit is


set to this number.

No default

value

<INTEGER, OFF,
NONE, ERROR,
ABORT>
See comments 1
and 2 for

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

119

Argument

Options

Description

defaults.

OFF or NONE: value=NONE can only be used if type


= ID. See Comment 3.
ERROR:

Valid only when the type is ID.


Messages with this ID will be treated as
ERRORs, that is, continuation at the end
of the current stage will be disallowed
unless the message is encountered
during the solver, where full postprocessing of the results will be allowed
before termination; optimization runs will
terminate as if the limit of allowed
iterations had been reached.

ABORT:

Valid only when type is ID.


Messages with this ID will be treated as
abort ERRORs, that is, the solver will
terminate immediately. If the message
is encountered during the solver, no
output files will be generated. If it
happens during reading or verification of
input data, then remaining parts of
input will not be processed.

mode

<STRICT,
UNREF, BRIEF>
Default =
<BRIEF>

STRICT:

All messages are printed according to


MSGLMT.

UNREF:

Messages 1931, 1932 and 2010 are


suppressed.

BRIEF:

Messages 741, 742, 1935, 1931, 1932,


2010, 1052, 1305, and 1436 are
suppressed.

Comments
1.

By default, the limit for most individual ERROR and WARNING/INFORMATION messages is
10.

2.

The default limit for the total number of ERROR messages is 10,000 and for the total
number of WARNING/INFORMATION messages is 1,000.

3.

The following table lists some special cases of MSGLMT usage:

120

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Special Cases

Effect

MSGLMT(Message ID/WARNING/
ERROR) = 1

Prevents any information about


consecutive occurrences of the
specified message to be registered
and counted.
If WARNING/ERROR is used, only the
first WARNING/ERROR is printed.

MSGLMT(Message ID/WARNING/
ERROR) = 0

Message ID: All occurrences of the


specified message will be displayed.

MSGLMT(Message ID/WARNING/
ERROR) = OFF

WARNING: All Warnings will be


displayed.
ERROR: All Errors will be displayed.

MSGLMT(Message ID) = NONE

The specified message (and multiple


occurrences of the same, if any) will
not be printed in the output file.
Note:
1. If the Message ID belongs to an
error, the specified error and multiple
occurrences of the same error will
not be printed in the output file.
However, this will not allow the
solver to continue after error
suppression. This can sometimes
generate an output file which states
that an error occurred without any
information regarding the nature of
the error, since it was suppressed.
2. Suppressed ERROR/WARNING
messages still count toward
respective limits and are reported in
the job summary.
3. Using MSGLMT(Message ID)=NONE
for ERROR messages is not
recommended.

MSGLMT(Message ID) = <Negative


Integer>

Negative values are not supported. A


Syntax error will be displayed, if
negative integer values are used.

4.

MSGLMT may be set in the OptiStruct Configuration File.

5.

Multiple instances of MSGLMT may occur. If any instances conflict, then the last instance
will be honored.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

121

6.

Some messages print lists of ID's, which can be very long, MSGLMT can be used to control
the number of ID's that are printed.
For Example:
MSGLMT, 1692, <Integer> or MSGLMT (1692) =<integer>, prints the first <integer>
number of duplicate GRID IDs:
*** WARNING # 1692
Found duplicate GRID cards, removed 74 item(s) of identical data.
10001

10002

(up to <integer> number)

MSGLMT, 1692, OFF or MSGLMT (1692) =OFF, prints all duplicate GRID IDs:
*** WARNING # 1692
Found duplicate GRID cards, removed 86 item(s) of identical data.
10001

122

10002

10003

10004

10005

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NLRESTART
I/O Options Entry
NLRESTART - Run Control Command
Description
The NLRESTART command can be used in the I/O Options section to indicate the current
nonlinear solution sequence is to be restarted from a specified nonlinear subcase.
Format
NLRESTART = n

Argument

Description

Nonlinear SUBCASE ID to be restarted from in the current


nonlinear solution sequence.
If n is not given, it will restart from the first nonlinear subcase
ending with error in previous run.

Comments
1.

This command applies only to geometric nonlinear subcases (ANALYSIS = NLGEOM,


IMPDYN or EXPDYN).

2.

Only one NLRESTART entry can be defined, and it must be above the first subcase.

3.

NLRESTART is also available in command line option as -nlrestart n or -nlrestart.


If NLRESTART is defined in both bulk data and command line option, the former overrides
the latter.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

123

OFREQUENCY
I/O Options and Subcase Information Entry
OFREQUENCY - Output Control
Description
The OFREQUENCY command can be used in the I/O Options or Subcase Information sections to
request a set of frequencies for output requests for all subcases or individual subcases
respectively.
Format
OFREQUENCY = option

Argument

Options

Description

option

<ALL, SID>

ALL, blank: Output is for all frequencies.

Default = ALL
SID:

If a set ID is given, output is only for


frequencies listed in that set.

Comments
1.

When OFREQUENCY is not present, output is for all frequencies.

2.

The SET definition referenced by the OFREQUENCY card must be a real value set.

3.

The number of solutions selected will always be equal to the number of quantities in the
selected set. The closest values will be used.

124

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

OLOAD
I/O Options and Subcase Information Entry
OLOAD - Output Request
Description
The OLOAD command can be used in the I/O Options or Subcase Information sections to
request the form of applied load vector output for all subcases or individual subcases
respectively.
Format
OLOAD (format_list,type) = option

Argument

Options

Description

format

<H3D, OPTI, PUNCH,


OP2, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in


OptiStruct results format
(.load file).

Default = blank

PUNCH:

OP2:

type

<SPARSE, ALL>

Results are output in Nastran


punch results format (.pch
file).
Results are output in Nastran
output2 format (.op2 file)
(see comment 6).

blank:

Results are output in all active


formats for which the result is
available.

ALL:

Output for all selected nodes


is printed.

SPARSE:

This is only available for the


OPTI output format. Output
for selected nodes without a
component of magnitude
1.0e-10 is not printed.

Default (OPTI) = SPARSE


Default (H3D, PUNCH, OP2)
= ALL

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

125

Argument

Options

Description

option

<NONE, NO, YES, ALL,


SID>

YES, ALL,
blank:

Load data is output for all


nodes.

NO, NONE:

Loads are not output.

SID:

If a set ID is given, load data


is only output for nodes listed
in that set.

Default = ALL

Comments
1.

When OLOAD command is not present, loads are not output.

2.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

3.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

4.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

5.

The SPARSE output type is only available when the OPTI output format is used.

6.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

126

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

OMODES
I/O Options Entry
OMODES - Output Control
Description
The OMODES command can be used in the I/O Options or Subcase Information sections to
request a set of modes for output requests for all subcases or for individual subcases,
respectively. This command is applicable for normal modes and linear buckling solution
sequences only.
Format
OMODES = option

Argument

Options

Description

option

<ALL, SID>

ALL, blank: Output is calculated for all modes.

Default = ALL
SID:

If a set ID is given, output is calculated for


only modes listed in that set.

Comments
1.

When OMODES is not present, output is for all modes.

2.

The SET definition referenced by the OMODES card must be an integer value set.

3.

This output control is not available for frequency response subcases; OFREQUENCY should
be used instead.

4.

If both the OMODES and OFREQUENCY requests appear, the OMODES request takes
precedence.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

127

OTIME
I/O Options and Subcase Information Entry
OTIME - Output Control
Description
The OTIME command can be used in the I/O Options or Subcase Information sections to
request a set of times for output requests for transient analysis for all subcases or individual
subcases respectively.
Format
OTIME = option

Argument

Options

Description

option

< ALL, SID >

ALL, blank:

Output is at all times.

SID:

If a set ID is given, output is only at times in


that set.

Default = ALL

Comments
1.

When an OTIME command is not present the output for all times will be computed.

2.

This command is particularly useful for requesting a subset of the output (for example,
stresses at only peak times, and so on).

128

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

OUTFILE
I/O Options Entry
OUTFILE - Filename Definition
Description
The OUTFILE command is used in the I/O Options section to define the prefix for the results
files output.
Format
OUTFILE = option

Argument

Options

Description

option

<file prefix>

file prefix: The path to and file prefix used for


the results files output.

Default = passed
in from the
command line.
Comments
1.

Prefixes specified on the OUTFILE card can be arbitrary file prefixes with optional paths
appropriate to the operating system (Windows or UNIX). They may be enclosed in quotes
(double or single quotes can be used), and either forward slash (/) or back slash (\)
characters can be used to separate parts of the path name.
The following rules are used for the OUTFILE card:
When the argument contains an absolute path of the file (if it starts with "/" on UNIX
or a drive letter, such as "D:", on Windows, for example), output files are created at
the given location.
When only the file prefix is given (without the path), output files will be created in the
current directory, meaning the directory from which the solver has been executed, and
not in the directory where the input file is located.
When the argument contains a relative path (../filename or sub/filename, for
example), output is created in a directory relative to where the solver is executed and
NOT relative to the directory where the input file is located.

2.

The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

129

OUTPUT
I/O Options Entry
OUTPUT Output Control
Description
The OUTPUT command can be used in the I/O Options section to control the format of results
output and the creation of certain results files.
Format
OUTPUT, keyword, frequency, option1, option2

Argument

Options

Description

keyword

See below

See below

frequency

FIRST, LAST,
FL, ALL, NONE,
N or blank

FIRST:

Output first iteration only.

LAST:

Output last iteration only.

FL:

Output first and last iterations.

ALL:

Output all iterations.

NONE:

No output

N:

Output first and last iterations and every Nth


iteration. If N=5, output occurs at iterations
0, 5, 10, 15, 20, and so on, and the final
iteration.

blank:

The default listed below for the given


keyword.

option

See below

See below

Standard Result Outputs


Note that if there is no result OUTPUT defined, then default result output is both HM and
H3D. If any result OUTPUT commands exist, then there is no default OUTPUT type.

130

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Keyword Description

HM

Output
results in
HyperMesh
binary
format.

Default
frequency
FL

Affect
ed
files
*.res

Options

Details

<NODMIG,
DMIGALL,
DMIGSET>

Determines whether or not to


output results for interior
points of external
superelements. See
comment 16.

Default =
DMIGSET

NODMIG: recovery is
deactivated
DMIGALL: recovery is
activated for all grids/
elements
DMIGSET: recovery is
activated for grids/elements
in the SET defined on the
corresponding output request
(default)

H3D,
HV

Output
results in
Hyper3D
format.

FL

*.h3d

<BYSUB,
BYITER>
Default =
BYSUB

Determines the way the


output files are arranged in
an optimization run. See
comment 15.

(Applicable to
optimization
runs only).
<NODMIG,
DMIGALL,
DMIGSET>
Default =
DMIGSET

Determines whether or not to


output results for interior
points of external
superelements. See
comment 16.
NODMIG: recovery is
deactivated
DMIGALL: recovery is
activated for all grids/
elements
DMIGSET: recovery is
activated for grids/elements
in the SET defined on the
corresponding output request

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

131

Keyword Description

Default
frequency

Affect
ed
files

Options

Details

(default)

OP2,
OUT2,
OUTPUT2

Output
analysis
results in
Nastran
output2
format.

FL

*.op2

<MODEL,
NOMODEL>

Turns on / off the output


of the model data to the file.

Default =
MODEL

See comments 11 and 12.

<NODMIG,
DMIGALL,
DMIGSET>
Default =
DMIGSET

Determines whether or not to


output results for interior
points of external
superelements. See
comment 16.
NODMIG: recovery is
deactivated
DMIGALL: recovery is
activated for all grids/
elements
DMIGSET: recovery is
activated for grids/elements
in the SET defined on the
corresponding output request
(default)

NASTRAN
, PUNCH

Output
analysis
results in
Nastran
punch
format.

FL

*.pch

<NODMIG,
DMIGALL,
DMIGSET>
Default =
DMIGSET

Determines whether or not to


output results for interior
points of external
superelements. See
comment 16.
NODMIG: recovery is
deactivated
DMIGALL: recovery is
activated for all grids/
elements

132

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Keyword Description

Default
frequency

Affect
ed
files

Options

Details

DMIGSET: recovery is
activated for grids/elements
in the SET defined on the
corresponding output request
(default)
OPTI,
ASCII,
OS

Output
results in
OptiStruct
ASCII
format.

FL

*.cstr
,
*.dens
,
*.disp
,
*.forc
e,
*.gpf,
*.load
,
*.mpcf
,
*.spcf
,
*.strs

PATRAN,
APATRAN

Output
analysis
results in
Patran
ASCII
format.

FL

*.#.#.
#.dis,
*.#.#.
dis,
*.#.#.
els,
*.#.di
s,
*.#.el
s,

(APATRAN
uses an
alternate
file naming
convention
, with the
iteration
number
after the
file
extension).

Altair Engineering

*.#.#.
dis.#,
*.#.di
s.#,
*.#.el
s.#,
*.dis.
#,
*.els.
#

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

133

Keyword Description

NONE

Default
frequency

Affect
ed
files

Default
frequenc
y

Affected
files

Results are
not output
in any of
the
formats
listed
above.

Options

Details

Optimization Outputs

Keyword

Description

DESIGN

Controls the
frequency of
output for
design results
such as
DENSITY,
SHAPE, and
THICKNESS

ALL

SHRES

Controls the
frequency of
output of the
shape files.

GRID

Requests the
output of the
state file (.grid
file) for
topography or
shape
optimization.

Options

Details

All files that


design results
are written
to.

*.sh,
*.grid

*.grid

<LOCAL, BASIC> BASIC: Grid


definitions are
Default = BASIC output to the
.grid file,
referencing the
basic coordinate
system.
LOCAL: Grid
definitions are
output to the
.grid file,
referencing local
coordinate
systems as

134

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Keyword

Description

Default
frequenc
y

Affected
files

Options

Details

defined by the
CP field on the
GRID definitions.
FSTOSZ

Automatic
generation of
a sizing model
after freesizing of a
composite
structure.

*_sizing.fe
m

1.

Bundles

See comment 18.

Integer > 0
Default = 4
2.

Method
<ADVFREE,
ADVMAN,
SIMFREE,
SIMMAN>
Default =
ADVFREE

3.

SZTOSH

Automatic
generation of
a shuffling
model after
ply-based
sizing
optimization.

*_shuffling
.fem

FSTHICK

Controls
output of freesizing results
to .fsthick
file.

*.fsthick

Requests the
output of
updated
design variable
values.

DESVAR

Ignore
<IGNORE>-

<YES, NO>

See comment
13.

Default = NO

*.desvar,
*.out

<FILE, OUT,
BOTH, NONE>
Default = FILE

FILE: Updated
property design
variable values
are output to
the .desvar file.
OUT: Updated
design variable
values are output
to the .out file.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

135

Keyword

Description

Default
frequenc
y

Affected
files

Options

Details

BOTH: Updated
design variable
values are output
to both the .out
file and the
.desvar file.
NONE: Updated
design variable
values are not
output.
PROPERTY

Requests the
output of the
updated
property
definitions.

*.prop,
*.out

<ANY, DESIGN,
FILE, OUT,
BOTH, NONE>

ANY: All
properties are
output.

Default =
DESIGN

DESIGN: Only
designable
properties are
output.

Note:
In the
Description
and Details
columns of the
PROPERTY
keyword:
Property
stands for
Properties,
Materials and
Elements.

FILE: Updated
property
definitions and
non-design
properties are
output to the
.prop file.
OUT: Updated
property
definitions and
non-design
properties are
output to the
.out file.
BOTH: Updated
property
definitions and
non-design
properties are
output to both
the .out file and
the .prop file.

136

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Keyword

Description

Default
frequenc
y

Affected
files

Options

Details
NONE: Updated
property
definitions are
not output.

Specialized Result Outputs

Keyword

Description

ADAMSMNF

Output of
flexible body to
a modal neutral
file for
MSC.ADAMS.

Default
Affected files
frequenc
y
-

*.mnf

Options

<YES, NO>

Details

Default = YES

See comment
17.
HGFREQ

Frequency
Analysis output
presentation for
HyperGraph.

FL

*_freq.mvw,
*_s#_a.frf,
*_s#_d.frf,
*_s#_v.frf

*_tran.mvw,
*_s#_a.trn,
*_s#_d.trn,
*_s#_v.trn

See comment
3.
HGTRANS

Transient
Analysis output
presentation for
HyperGraph.
See comments
2 and 3.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

137

Keyword

Description

HGMBD

Multi-body
Dynamics
output
presentation for
HyperGraph.

Default
Affected files
frequenc
y
-

*_mbd.mvw,
*_s#_a.mbd,
*_s#_d.mbd,
*_s#_v.mbd

Options

Details

See comments
2 and 3.
HGSENS

Sensitivity
output
presentation for
HyperGraph.

FL

*_sens.#.mvw,
*.#.sens

<ALL,
NOSTRESS,
STRESS>

See comment 4
for details on
options.

Default =
NOSTRESS
MSSENS

Sensitivity
output in
Microsoft Excel
SYLK format.

FL

*.#.slk

<ALL,
NOSTRESS,
STRESS>

See comment 4
for details on
options.

Default =
NOSTRESS
ASCSENS

H3DSENS

H3DTOPOL

138

Topology and
free-sizing
sensitivity
(response with
respect to
design element
density) output
in ASCII format.

FL

Sensitivity
output in H3D
format.

FL

Sensitivity
output in H3D
format for
contouring of
topology and

FL

*.#.asens

<ALL,
NOSTRESS,
STRESS>

See comment 4
for details on
options.

Default =
NOSTRESS

*_dsa.#.h3d

<USER,
NOUSER>
Default =
NOUSER

*_topol.#.h3d

<ALL,
NOSTRESS,
STRESS>

See comment
19 for details
on options.

See comment 4
for details on
options.

Default =

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Keyword

Description

Default
Affected files
frequenc
y

free-sizing
sensitivity.
H3DGAUGE

HGHIST

Sensitivity
output in H3D
format for
contouring of
shell thickness
sensitivity.
Design history
output
presentation for
HyperGraph.

HGEFFMASS Effective mass


is output as a
HyperGraph bar
chart.
HGMODFAC

DVGRID

Modal
participation
factor output
presentation for
HyperGraph3D.
Output of
shape variable
definitions to
.dvgrid file.

Options

Details

NOSTRESS

FL

*_gauge.#.h3d

<ALL,
NOSTRESS,
STRESS>

See comment 4
for details on
options.

Default =
NOSTRESS
-

FL

*_hist.mvw,
*.hist
*.hgdata

*.mass,
*_mass.mvw

*_modal.mvw,
*_modal.#.mvw

Integer < 32
Default = 31

<REGULAR,
NORM>

See comment 5
for details on
options.

See comment
14.

Default =
REGULAR
-

*.dvgrid

*.out

The center of
gravity is
specified in the
basic
coordinate
system. The
Mass Properties
are with
respect to the

See comment
6.
MASSPROP

Controls the
output of
Center of
Gravity and
Mass Moments
of Inertia tables
based on
properties to
.out file.

Altair Engineering

FL

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

139

Keyword

Description

Default
Affected files
frequenc
y

Options

Details

center of
gravity of the
item.
MASSCOMP

Controls the
output of Mass
based on
HyperMesh
Components to
.out file.

REGCOMPL

Controls the
output of
regional
compliance
table to .out
file.

FL

*.out

*.out

<YES, NO>
Default = YES

File Output Controls

Keyword

Description

CMF

Controls output
of .cmf files.

OSS

Default
frequenc
y

Affected files

Options

*.HM.badel.c
mf,
*.HM.comp.cm
f,
*.HM.ent.cmf
,
*.HM.conn.cm
f

<YES, NO>
Default = YES

Controls output
of .oss file.

*.oss

<YES, NO>
Default = YES

HTML

Controls output
of .html file.

*.html

<YES, NO>
Default = YES

STAT

Controls output

*.stat

<YES, NO>

140

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Details

See comment 9.

Altair Engineering

Keyword

Description

Default
frequenc
y

Affected files

of .stat file.

Options

Details

Default = YES

Comments
1.

Frequency does not apply for any of the keywords where a dash (-) is given as the
default frequency in the keywords table above.

2.

HGTRANS and HGMBD are currently available for analysis only.

3.

HGFREQ, HGTRANS, and HGMBD will only use output requests where a Set ID is specified.
For example, if DISPLACEMENT = ALL or DISPLACEMENT(HG) = ALL is given, displacement
information will not be present in the presentation, whereas if DISPLACEMENT = 1 or
DISPLACEMENT(HG) = 1 is given, displacement information will be present in the
presentation for the constituent nodes of Set 1.

4.

For HGSENS, ASCSENS, or MSSENS options:


If NOSTRESS or blank: results are printed, but stress, strain, and force responses are
ignored.
If ALL or STRESS: results are printed, including stress, strain, and force responses.

5.

For HGHIST options:


The integer value given is equal to the sum of the desired options:
1: Design Variable.
2: Objective function and maximum % constraint violation.
4: All non-stress responses.
8: All DRESP2 responses.
16: All DRESP3 responses.
If blank: all of the above are output.
For example: If you want Design Variables and all DRESP2 responses, you would use 9.

6.

The DVGRID option creates shape variable definitions for displacement or eigenvector
results of linear static, normal modes, or liner buckling analyses. These shape variable
definitions can then be used in subsequent optimizations. This process facilitates the use
of "natural" shape functions.

7.

For the keywords HM, H3D, HV, ASCII, OPTI, OS, NASTRAN, PUNCH, OP2, OUT2,
OUTPUT2, PATRAN and APATRAN, the information provided by the OUTPUT I/O option
entry takes precedence over information provided on the older FORMAT and RESULTS I/O
option entries.

8.

OUTPUT entries are read sequentially; therefore, where multiple OUTPUT entries exist with
the same keyword, the last instance is used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

141

9.

If OUTPUT,STAT,NO is defined, the *.stat file is deleted at the end of the run (as long as
the run was successful), but the file always exists during the run.

10. OUTPUT,DESIGN takes precedence over the information provided on the older DENSRES I/O
option entry. OUTPUT,DESIGN will write design results, at the frequency defined, to all
active output formats (HM, H3D, or OPTI), regardless of the frequency chosen for that
output format. By default, HM is the only active output format.
11. When CMSMETH is used, or when a full multi-body dynamics run is performed, the CMS
stress modes can be written to OP2 format. This only happens when OUTPUT,OP2 (or
FORMAT,OP2) is defined. One file for each is generated. Stresses are written for shells
and solids, while forces are written for bars/beams and welds. Each mode is written as a
static load case with ID equal to the mode index. This output is compatible with FEMFAT
by MAGNA.
12. The MODEL/NOMODEL option for OUTPUT, OP2 may be overridden by the PARAM, OGEOM
bulk data entry.
13. The FSTHICK keyword generates a file with the .fsthick extension. The file contains
bulk data entries for elements (CQUAD4, CQUAD8, CTRIA3, and CTRIA6) contained in freesize design spaces. The element definitions have the optimized thickness defined as
nodal thicknesses (Ti) for each element.
14. The HGMODFAC keyword generates a HyperGraph3D presentation providing 3D plots of
modal participation factors. The plots display the mode number on the x-axis, the
frequency (for frequency response analyses) or time (for transient analyses) on the yaxis and the modal participation factor on the z-axis.
The NORM option normalizes the participation factors with respect to 1.
In HyperGraph3D, it is possible to define cross-sections to generate 2D plots of either:
a) Modal participation factor vs. frequency or time for a given number.
b) Modal participation factor vs. mode number at a given frequency or time.
For frequency response analyses, plots are generated for the real part, the imaginary part
and the magnitude of the participation factors. Magnitude plot is visible by default, while
real and imaginary plots are hidden by default.
15. The H3D output from optimization runs consists of a number of files. The BYSUB/BYITER
option allows switching between two modes of H3D output. There is a no default option
(BYSUB/BYITER) for analysis runs.
BYSUB (This is the default option for optimization runs) outputs one _des.h3d file for
the animation of the optimization history. The frequency of the optimization results in
this file is defined by OUTPUT, DESIGN (Default = ALL). In addition, an _si.h3d file for
each subcase i is written that contains the history of the analysis results for each
subcase. Frequency determines the analysis result output frequency. Optimization
results can be written to the subcase files using DENSITY, SHAPE, or THICKNESS output
requests.
(Using OUTPUT, H3D, or BYSUB for analysis runs (without optimization) will output the
same files as above (except for the _des.h3d file), however no design results or
analysis history will be available within the files).

142

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BYITER outputs one .#.h3d file per iteration that contains the optimization and
analysis results for all subcases per iteration. Frequency determines at which iteration
these files are created. It overwrites the default of OUTPUT, DESIGN unless an actual
OUTPUT, DESIGN statement is present. In the case of a shape optimization, the GRID
coordinates of the model in the respective iteration are updated to the new shape.
(Using OUTPUT, H3D, or BYITER for analysis runs (without optimization) will output
only one .h3d file since there are no multiple iterations).
16. Results for interior points of external superelements will be output by default to HM, H3D,
PUNCH, and OP2 files.
17. If GPSTRESS output is requested in addition to OUTPUT, ADAMSMNF, then nodal stress
results for solid elements will be written to the .mnf file.
18. For FSTOSZ options:
Bundles: This specifies the number of ply bundles to be generated per fiber orientation.
Method: Ply bundle thicknesses are determined based on the method defined.
ADVFREE: Advanced algorithm with free thicknesses.
ADVMAN: Advanced algorithm with manufacturable thicknesses.
SIMFREE: Simple algorithm with free thicknesses.
SIMMAN: Simple algorithm with manufacturable thicknesses.
The advanced algorithm is available for 2, 4 and 8 ply bundles. It takes into account the
thickness distribution when generating the ply bundles, which results in a more accurate
representation of the original free-sized thickness profile.
Ply bundle thickness can also be multiples of the manufacturable ply thickness.
Ignore: Elements may be ignored in a given ply orientation when their thickness is less
than 5% of the maximum thickness. This option is inactive by default.
19. H3DSENS, USER indicates that the user-defined responses should be included in the DSA
output. NOUSER indicates that user-defined responses should not be included. In both
cases, responses defined through the DSA output request are included in the DSA output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

143

PFGRID
I/O Options Entry
PFGRID Output Request for Acoustic Grid Participation
Description
The PFGRID command can be used in the I/O Options section to request output of acoustic
grid participation factors for all frequency response subcases. The output will be in the .h3d
file.
Format
PFGRID (GRIDS=setg, GRIDF=setfl, FREQUENCY=setf, NULL=ipower, RPCUTOFF=rval,
RPDBACUT=rpdba, CONTOUR=YES/NO,PEAKOUT) = setdof/PEAKOUT
Examples
PFGRID(FREQUENCY=391)=12
PFGRID(PEAKOUT)=23
PFGRID(PEAKOUT)=PEAKOUT

Argumen Options
t

Description

setg

ALL:

Output acoustic grid participation for all structural grid


points at the fluid-structure interface.

NONE:

Do not output acoustic grid participation for any


structural grid points.

SID:

Output acoustic grid participation factors for a set of


grids. SID refers to the ID of a SET of type GRID.

ALL:

Output acoustic grid participation for all fluid grid points


at the fluid-structure interface.

NONE:

Do not output acoustic grid participation for any fluid


grid points.

SID:

Output acoustic grid participation factors for a set of


grids. SID refers to the ID of a SET of type GRID.

<ALL, NONE,
SID>
Default = NONE

setfl

<ALL, NONE,
SID>
Default = NONE

144

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argumen Options
t

Description

setf

ALL:

Participation factors are processed for all excitation


frequencies.

SID:

Participation factors are only processed for a set of


excitation frequencies. SID refers to the ID of a SET of
type FREQ.

<ALL, SID>
Default = ALL

ipower

<INTEGER>

When the magnitude of a grid participation is below 10 to the


minus ipower, the grid participation will not be output. In other
words, if the grid participation is less than 10-ipower, the result
output for this grid will be skipped.

Default = 30

rval

<REAL>
Default = 0.0

rpdba

<NonNegative
REAL>
Default = 0.0

CONTOUR

(YES/NO)
Default = YES

PEAKOUT

The grid participation will be calculated at the excited


frequencies when the magnitude of the pressure is above rval.
The excitation frequency will be a subset of setf.

RPDBACUT is the decibel pressure cutoff value for fluid


responses, and is similar to RPCUTOFF. It will take precedence
over RPCUTOFF for fluid responses. A weighting is applied to
RPDBACUT values at the excitation frequency. The grid
participation will be calculated when the magnitude of the
response is about the cutoff value. See comment 4 for decibel
calculations and reference pressure settings.

If CONTOUR is specified as YES, the area projected value for the


fluid grid participation is output. Otherwise, the output of fluid
grid participation would be the actual complex value.

If PEAKOUT is present as an option inside the parenthesis of the PFGRID data,


then the filtered frequencies from the PEAKOUT data will be considered for output
of grid participation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

145

Argumen Options
t

Description

setdof/
PEAKOUT

Degrees of freedom for which the grid participation factors are


to be processed. SID refers to the ID of a SET of type GRID.
If PEAKOUT is specified instead of SID, the output will be
considered at the filtered frequencies corresponding to the
degree of freedom in the PEAKOUT card in the bulk section.

<SID/
PEAKOUT>

Comments
1.

Output is to the H3D file only.

2.

Acoustic grid participation factors are available in a coupled frequency response analysis
(both in direct and modal frequency response).

3.

The FREQUENCY keyword can be used to select a subset of excitation frequencies


available.

4.

The dB value is calculated using 20 * log10(P/P0), where P0 is the reference pressure.


The reference pressure is dependent on the units specified on the UNITS input data. If
the units are SI, the value is set as 2.0E-5 Pa. If they are CGS, it is set as 2.0E-4 barye.
If they are MPa, it is set as 2.0E-11 MPa. If they are BG or EE, then it is set as 4.17E-7
lbf/ft 2. If no UNITS data is present, the default value is 2.0E-11 MPa.

146

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFMODE
I/O Options Entry
PFMODE Output Request for Modal Participation
Description
The PFMODE command can be used in the I/O Options section to request output of modal
participation factors for all modal frequency response subcases.
Format
PFMODE (type, FLUIDMP=fmp, STRUCTMP=smp, PANELMP=setp, FREQUENCY=setf,
FILTER=fratio, NULL=ipower, RPCUTOFF=rval, RPDBACUT=rpdba, MTYPE=otype,
CMSSET=seset, RTYPE=rtype, outfile, PEAKOUT) = setdof/PEAKOUT
Examples
PFMODE(FLUID,STRUCTMP=30,FREQUENCY=391,PANELMP=ALL)=393
PFMODE(STRUCTURE,H3D)=23
PFMODE(FLUID,H3D,PEAKOUT)=11
PFMODE(STRUCTURE,H3D,PEAKOUT)=PEAKOUT
PFMODE(FLUID,PUNCH)=31

Argument Options

Description

type

STRUCTURE:

Requests output of structural modal participation


factors.

FLUID:

Requests output of acoustic modal participation


factors.

ALL:

Participation factors will be computed for all


calculated fluid modes.

<STRUCTURE,
FLUID>
Default =
STRUCTURE

fmp

<ALL, N,
NONE>

Default = NONE N:

NONE:

Altair Engineering

Number of fluid modes for which modal


participation factors will be computed, based on
the largest magnitude of modal contribution.
Participation factors are not calculated for fluid
modes.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

147

Argument Options

Description

smp

ALL:

<ALL, N,
NONE>

Default = NONE N:

setp

<ALL, NONE>

<ALL, SID>

Participation factors are not calculated for


structural modes.

ALL:

Output structural modal participation for each


panel specified in the PANEL data.

NONE:

Do not output panel modal participation.

ALL:

Participation factors are processed for all


excitation frequencies.

SID:

Participation factors are only processed for a set


of excitation frequencies. SID refers to the ID of
a SET of type FREQ.

Default = ALL

fratio

<REAL>

Specifies the value of a filter to be applied to the output.


Values of modal participation below fratio times the
displacement or pressure are not output.

Default =
0.001

ipower

<INTEGER>

When the magnitude of a modal participation is below 10 to the


minus ipower, the modal participation will not be output. In
other words, if the modal participation is less than 10-ipower, the
result output for this mode will be skipped.

Default = 30

rval

<REAL>
Default = 0.0

148

Number of structural modes for which modal


participation factors will be computed based on
the largest magnitude of modal contribution.

NONE:

Default = NONE

setf

Participation factors will be computed for all


calculated structural modes.

The modal participation will be calculated at the excited


frequencies when the magnitude of the response is above rval.
The excitation frequency will be a subset of setf.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument Options

Description

rpdba

<Non-Negative RPDBACUT is the decibel pressure cutoff value for fluid


responses, and is similar to RPCUTOFF. It will take precedence
REAL>
over RPCUTOFF for fluid responses. A weighting is applied to
Default = 0.0 RPDBACUT values at the excitation frequency. The modal
participation will be calculated when the magnitude of the
response is about the cutoff value. See comment 9 for decibel
calculations and reference pressure settings.

otype

<ALL, SYSTEM, For SYSTEM, the output related to PFMODE will correspond to
CMS>
the whole model. Component modal participation will not be
output by default. However, when using ALL or CMS, the
Default =
component modal participation will be output. For the CMS
SYSTEM
option, there will not be system modal participation. Component
modal participation can also be calculated for internal grids in
the superelement.

seset

<ALL, SID>
Default = ALL

Component modal participation of all the H3D superelements will


be output by default. However, you can specify a specific set
of superelement names for output.

rtype

<DISP, VELO,
ACCE>

The Structural modal participation will be output for


Displacement, Velocity or Acceleration respectively based on
Default = DISP the specified option (DISP, VELO, ACCE).

outfile

<PUNCH, H3D> Modal participation can be exported either into the H3D file or
PUNCH file. Because of the large volume of data, it is
Default = H3D
recommended to export the modal participation data into a H3D
file.

PEAKOUT

If PEAKOUT is present inside the bracket of the PFMODE option, the filtered
frequencies from the PEAKOUT card will be considered for the output of modal
participation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

149

Argument Options

Description

setdof/
PEAKOUT

Degrees-of-freedom for which the participation factors are to be


processed. SID refers to the ID of a SET of type GRIDC for
structure participation and GRID for fluid participation. If
PEAKOUT is specified instead of SID, the output will be
considered at the filtered frequencies corresponding to the
degree of freedom on the PEAKOUT card in the bulk section.

<SID/
PEAKOUT>

Comments
1.

The output of both the PFMODE and PFPANEL must be either to an H3D file or to a PUNCH
file. Both PFPANEL and PFMODE must have the same output option.

2.

The modal participation output is sorted in descending order by magnitude of the modal
participation in the PUNCH file output.

3.

PFMODE(FLUID,..) and PFMODE(STRUCTURE,) can coexist in the input data, but only
one PFMODE(FLUID) and one PFMODE(STRUCTURE) are allowed in a single SUBCASE.

4.

Keywords FLUIDMP and PANELMP are only valid if FLUID is specified.

5.

If STRUCTURE is specified, setdof must reference a set of structural degrees-of-freedom.


If FLUID is specified, setdof must reference a set of acoustic degrees-of-freedom.

6.

The FREQUENCY keyword can be used to select a subset of excitation frequencies


available.

7.

The filter is applied to the magnitude of the modal participation factors. Only modal
participation factors that pass the filter are output.

8.

If the magnitude of the total response at a selected response degree-of-freedom is less


than 10-ipower, then no modal participation factors are processed. If ipower is not in the
range of 1 to 31, the default of 30 is used.

9.

The dB value is calculated using 20 * log10 (P/P0), where P0 is the reference pressure.
The reference pressure is dependent on the units specified on the UNITS input data. If
the units are SI, the value is set as 2.0E-5 Pa. If they are CGS, it is set as 2.0E-4 barye.
If they are MPa, it is set as 2.0E-11 MPa. If they are BG or EE, then it is set as 4.17E-7
lbf/ft 2. If no UNITS data is present, the default value is 2.0E-11 MPa.

10. Legacy format for the export of modal participation to H3D or PUNCH files: PFMODE (type,
OUTPUT=outfile)=setdof/PEAKOUT is also supported.
11. If you wish to output modal participation factors for interior points of a superelement (in a
CMS model), the SEINTPNT entry can be used in the subcase information section to
convert the interior points of interest to exterior points. After conversion, these points
can now be referenced by the <SID/PEAKOUT> option for the sedof/PEAKOUT argument.

150

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFPANEL
I/O Options Entry
PFPANEL Output Request for Acoustic Panel Participation
Description
The PFPANEL command can be used in the I/O Options section to request output of acoustic
panel participation factors for all frequency response subcases.
Format
PFPANEL (PANEL=setp, FREQUENCY=setf, outfile,peakout) = setdof/PEAKOUT
Examples
PFPANEL(PANEL=ALL,FREQUENCY=45)=12
PFPANEL(H3D, PEAKOUT)=56
PFPANEL(H3D, PEAKOUT)=PEAKOUT
PFPANEL(PUNCH)=32

Argumen Options
t

Description

setp

ALL:

Output acoustic panel participation for all panels.

NONE:

Do not output acoustic panel participation.

ALL:

Participation factors are processed for all excitation


frequencies.

SID:

Participation factors are only processed for a set of


excitation frequencies. SID refers to the ID of a SET
of type FREQ.

<ALL, NONE>
Default = NONE

setf

<ALL, SID>
Default = ALL

outfile

<PUNCH, H3D>
Default = H3D

Altair Engineering

Panel participation can be exported either into a H3D file or a


PUNCH file. Because of the large volume of data, it is
recommended to export the panel participation data into a H3D
file.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

151

Argumen Options
t

Description

PEAKOUT

If PEAKOUT is present as an option inside the parentheses of the PFPANEL data,


then the filtered frequencies from the PEAKOUT data will be considered for output
of panel participation.

setdof/
PEAKOUT

<SID/
PEAKOUT>

Degrees-of-freedom for which the panel participation factors


are to be processed. SID refers to the ID of a SET of type
GRID. If PEAKOUT is specified instead of SID, the output will
be considered at the filtered frequencies corresponding to the
degree-of-freedom in the PEAKOUT card in the bulk section.

Comments
1.

Output is to the H3D or PUNCH files only. The output of both PFMODE and PFPANEL must
be either to an H3D file or to a PUNCH file. Both PFPANEL and PFMODE must have the same
output option.

2.

Acoustic panel participation factors are available in a coupled frequency response analysis
(both in direct and modal frequency response).

3.

The FREQUENCY keyword can be used to select a subset of excitation frequencies


available. The closest loading frequency will be chosen in this case.

4.

Legacy format for the export of acoustic panel participation to H3D or PUNCH files:
PFPANEL (OUTPUT=outfile)=setdof/PEAKOUT is also supported.

152

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFPATH
I/O Options Entry
PFPATH Output Request
Description
The PFPATH command can be used in the I/O Options section for transfer path analysis for a
response at the connection points.
Format
PFPATH = SID
Comments
SID references a PFPATH card in the Bulk Data section.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

153

POWERFLOW
I/O Options Entry
POWERFLOW Output Request
Description
The POWERFLOW command can be used in the I/O Options section to request output of the
power flow field.
Format
POWERFLOW (format,peakoutput) = option

Argument Options

Description

format

H3D:

Results are output in Hyper3D format (.h3d file).

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will be
considered for this output.

<H3D>
Default = H3D

peakoutpu <PEAKOUT>
t
Default =
blank

option

<YES, ALL, NO, YES, ALL,


NONE, SID>
blank:
Default = ALL

Power flow field is output for all elements.

NO, NONE:

Power flow field is not output.

SID:

If a set ID is given, power flow field is output


only for the contents of that set.

Comments
1.

Power flow field output is only available to the .h3d file.

2.

The power flow field indicates the magnitude and direction of vibrational energy which
travels in dynamically loaded structures. It helps with identifying the energy transmission
paths as well as the vibration sources and energy sinks. Structural intensity, defined as
the power flow per unit area, is also available.

3.

The references used in the calculation of the power flow field are listed in the References
section of the Users Guide.

154

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PRESSURE
I/O Options and Subcase Information Entry
PRESSURE - Output Request
Description
The PRESSURE command is analogous to the DISPLACEMENT command. Refer to the
documentation for the DISPLACEMENT command.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

155

PRETBOLT
I/O Options and Subcase Information Entry
PRETBOLT - Output Request
Description
The PRETBOLT command can be used in the I/O Options or Subcase Information sections to
request output of pretension force/adjustment values in the pretension bolts for all
pretensioning and pretensioned subcases.
Format
PRETBOLT (format) = option

Argument

Options

Description

format

<OPTI, blank>

OPTI:

Results are output in OptiStruct results


format (.pret file).

blank:

Results are output in all active formats


for which the result is available.

YES:

Pretension force/adjustment values are


output for all bolts.

NO:

Pretension force/adjustment values are


not output.

Default = blank

option

<YES, NO>
Default = YES

Example
PRETBOLT (OPTI) = YES
PRETBOLT = NO
PRETBOLT (OPTI)
PRETBOLT
Comments
1.

When a PRETBOLT command is not present, pretension force/adjustment values are not
output.

2.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

156

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PROPERTY
I/O Options Entry
PROPERTY - Output Control
Description
The PROPERTY command can be used in the I/O Options section to request the output of the
property definitions used in the final iteration of an optimization.
Format
PROPERTY = option

Argument

Options

Description

option

<FILE, OUT,
BOTH, NONE>

FILE or blank: Updated property definitions are output


to the .prop file.

Default = FILE

OUT:

Updated property definitions are output


to the .out file.

BOTH:

Updated property definitions are output


to both the .out file and the .prop file.

NONE:

Updated property definitions are not


output.

Comments
1.

When a PROPERTY command is not present the updated property definitions will not be
output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

157

RADSND
I/O Options and Subcase Information Entry
RADSND - References RADSND Bulk Data to specify sound generation panels and microphone
field points
Description
The RADSND command can be used in the I/O Options or Subcase Information sections to
request radiated sound output for all subcases or individual subcases respectively.
Format
RADSND = option

Argument

Options

Description

option

<SID>

SID:

ID of RADSND bulk data entry.

No default
Comments
1.

158

Multiple instances of this card are allowed. If the instances are conflicting, the last
instance will be considered.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RCROSS
I/O Options Entry
RCROSS Output Request
Description
The RCROSS command can be used in the I/O Options section to request computation and
output of cross-power spectral density functions for random response analysis.
Format
RCROSS(format_list,form,type, randid=RANDPS_ID) = option

Argume
nt

Options

Description

format

<PUNCH,
blank>

PUNCH:

Results are output in Nastran punch results format


(.pch file).

blank:

Results are output in all active formats for which the


result is available.

COMPLEX:

Provides a combined magnitude/phase form of


complex output to the .res file if HM output format
is chosen. The REAL form of complex output is used
for other formats if they are not specifically defined.
(Phase output is in degrees).

REAL or
IMAG:

Provides rectangular format (real and imaginary) of


complex output.

PHASE:

Provides polar format (phase and magnitude) of


complex output.

BOTH:

Provides both rectangular and polar formats of


complex output.

PSDF:

Requests the cross-power spectral density function


be calculated and output for random analysis postprocessing.

Default =
blank

form

<COMPLEX,
REAL, IMAG,
PHASE,
BOTH>
Default =
COMPLEX

type

<PSDF>
Default =
PSDF

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

159

Argume
nt

Options

Description

option

<RCROSS_ID> RCROSS_ID:

Set identification of an RCROSS bulk data entry.

randid

<RANDPS_ID, RANDPS_ID:
blank>

Set identification number of a RANDPS bulk data


entry (see comments 3 and 4).

Comments
1.

The RCROSS I/O option must be used in conjunction with the RANDOM subcase information
entry.

2.

Response quantities, such as DISPLACEMENT, STRESS and STRAIN, must be requested by


corresponding I/O Options in order to compute cross-power spectral density between the
two response quantities specified by the RCROSS bulk data entry.

3.

Multiple RCROSS bulk data entries must be defined when each RCROSS subcase
information entry references different randid.
For example:
rcross(PUNCH,
rcross(PUNCH,
rcross(PUNCH,
rcross(PUNCH,

4.

160

PHASE,
PHASE,
PHASE,
PHASE,

PSDF,
PSDF,
PSDF,
PSDF,

randid=210020)=451
randid=210050)=452
randid=210070)=453
randid=210090)=454

randid=<RANDPS_ID> must be specified within the RCROSS I/O options entry when
multiple RANDOM subcase information entries are present.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

REQUEST
I/O Options and Subcase Information Entry
REQUEST Multi-Body Request Selection
Description
The REQUEST command can be used in the I/O Options or Subcase Information sections to
select a multi-body request definition to be used in a multi-body problem.
Format
REQUEST = option

Argument

Option

Description

option

<SID>

SID:

Set identification of MBREQ, MBREQE, or MBREQM


bulk data entries.

No default
Comments
1.

Only one REQUEST entry can be present for each subcase.

2.

This subcase information entry is only valid when it appears in a multi-body subcase.

3.

If the SID referenced by the REQUEST subcase information entry matches with the SID
defined for an MBREQ bulk data entry, the information on this entry alone is selected.
However, if no MBREQ bulk data entry has the referenced SID defined, any of the multibody motion entries: MBREQE or MBREQM which have this SID will be selected.

4.

If present above the first subcase, it is applied to each multi-body dynamics subcase
without a REQUEST entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

161

RESPRINT
I/O Options Entry
RESPRINT - Output Control
Description
The RESPRINT command can be used in the I/O Options section to force all unretained
responses of a certain type to be printed to the output file, provided they are referenced
either as an objective or a constraint. This also applies to manufacturing constraints for
composites.
Format
RESPRINT = option

Argument Options

Description

option

MASS:

Mass and massfrac


responses are output.

VOLUME:

Volume and volfrac


responses are output.

DISP:

Acceleration, Displacement
and Velocity responses are
output.

BUCK:

Buckling responses are


output.

STRESS:

Stress responses, including


CSTRESS and CFAILURE
responses, are output.

FREQ:

Frequency responses are


output.

EQUA, WCOMP,
WFREQ, or COMB:

All equation and combination


responses are output.

EXTERNAL:

External responses (defined


by DRESP3) are output.

COMP:

Compliance responses are


output.

<MASS, VOLUME, DISP,


BUCK, STRESS, FREQ,
EQUA, EXTERNAL, WCOMP,
WFREQ, COMB, COMP,
STRAIN, FORCE, COG,
INERTIA, MANUF, ALL>
No default

162

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument Options

Description
STRAIN:

Strain responses, including


CSTRAIN responses, are
output.

FORCE:

Force responses are output.

COG:

Center of gravity responses


are output.

INERTIA:

Inertia responses are output.

MANUF:

Manufacturing constraints for


composites are output.

ALL:

All design responses are


output. However,
manufacturing constraints for
composites are not listed.

Comments
1.

When a RESPRINT command is not present, only retained responses will be output.

2.

The arguments may be placed on a single card in a comma-separated list.


For example:
RESPRINT = STRESS, DISP
will force all stress and displacement responses referenced as either an objective or
constraint to be output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

163

RESTART
I/O Options Entry
RESTART - Run Control Command
Description
The RESTART command can be used in the I/O Options section to indicate that the current
optimization is to be restarted from the final iteration of a previous optimization.
Format
RESTART = option

Argument

Options

Description

option

<File prefix>

File prefix:

Default = prefix of .fem


file

The prefix of the .sh file to be


used as the starting iteration
for the restart.

Comments
1.

To restart an optimization, you will need information about the final iteration of a previous
optimization run. This information is contained in the .sh file.

2.

The purpose of the restart functionality is for restarting with unconverged optimization
runs or optimization runs that were terminated before completion (due to a power outage,
and so on). Only limited changes are allowed to be made to the model data. Refer to
the User's Guide section Restarting OptiStruct.

3.

This I/O Option is not valid for analysis mode.

4.

Output files from a restart run are appended with the extension _rst#, where # is a 3
digit number indicating the starting iteration for the restart run. For example,
filename_rst030.out is the .out file created when restarting filename.fem from
iteration 30.

5.

The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

164

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RESULTS
I/O Options Entry
RESULTS - Output Control
Description
The RESULTS command can be used in the I/O Options or Subcase Information sections to
determine the frequency of output of analysis results for all subcases or for individual
subcases respectively.
Format
RESULTS = frequency

Argument

Options

Description

frequency

<FIRST, LAST, FL,


ALL, NONE, N>

FIRST:

Output analysis results for the first


iteration only.

Default = FL

LAST:

Output analysis results for the final


iteration only.

FL, blank:

Output analysis results for both the first


and last iterations.

ALL:

Output analysis results for all iterations.

NONE:

Do not output analysis results.

N:

Output analysis results for the first and


last iterations and for every Nth
iteration. If N = 5, output occurs for
iterations 0, 5, 10, 15, 20, and so on,
and the final iteration. All equation and
combination responses are output.

Comments
1.

When a RESULTS command is not present, analysis results are output for formats that are
activated by the FORMAT command for both the first and last iterations.

2.

The information on this card pertains to all analysis output formats that are not
specifically described by an OUTPUT command.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

165

3.

166

It is recommended to use the OUTPUT command as it allows different frequencies of


output to be defined for different formats.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SACCELERATION
I/O Options and Subcase Information Entry
SACCELERATION - Output Request
Description
The SACCELERATION command can be used in the I/O Options or Subcase Information sections
to request the form and type of modal participation accelerations output for all subcases or
individual subcases respectively.
Format
SACCELERATION (sorting,format_list,form,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format


(.pch file) or the OUTPUT2 format (.op2 file) output
for normal modes, frequency response, and
transient subcases. It will be ignored without
warning if used elsewhere.

Default = blank

format

SORT1:

Results for each frequency/


timestep are grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment
7).

blank:

SORT1 is used for all results


except for transient analysis,
where SORT2 is used.

<H3D, PUNCH, OP2,


PLOT, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

Default = blank

PUNCH:

Results are output in Nastran


punch results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 9).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

167

Argument

form

Options

Description
PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the
bulk data section.

blank:

Results are output in all active


formats for which the result is
available.

REAL or IMAG:

Provides rectangular format (real


and imaginary) of complex
output.

PHASE:

Provides polar format (magnitude


and phase) of complex output.
Phase output is in degrees.

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the
PEAKOUT card will be considered
for this output.

<YES, ALL, NO,


NONE>

YES, ALL, blank:

Results are output.

Default = ALL

NO, NONE:

Results are not output.

<REAL, IMAG,
PHASE>
Default = REAL

peakoutput

<PEAKOUT>
Default = blank

option

Comments
1.

When the SACCELERATION command is not present, modal participation accelerations are
not output.

2.

The SACCELERATION command is only valid for modal frequency response and modal
transient solution sequences.

3.

The OFREQUENCY and OTIME I/O Options may be used to control the amount of output.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

168

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

7.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

8.

The abbreviations SACCE and SACCEL are interchangeable with SACCELERATION.

9.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

169

SCREEN
I/O Options Entry
SCREEN - Output Control
Description
The SCREEN command can be used in the I/O Options section to control the output of model,
analysis, and optimization information to the UNIX or DOS shell.
Format
SCREEN = option

Argument

Options

Description

option

<OUT, LOG,
NONE>

OUT, blank:

The .out file is echoed to the screen.

Default = NONE

LOG:

A log of the optimization process is echoed


to the screen.

NONE:

No information is echoed to the screen.

Comments
1.

When a SCREEN command is not present, no information is echoed to the screen.

2.

If the option LOG is chosen, the value of the objective function and the maximum
constraint violation at every iteration, as well as indication of satisfied convergence
ratios, are echoed to the screen.

170

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SDISPLACEMENT
I/O Options and Subcase Information Entry
SDISPLACEMENT - Output Request
Description
The SDISPLACEMENT command can be used in the I/O Options or Subcase Information sections
to request the form and type of modal participation displacements output for all subcases or
individual subcases respectively.
Format
SDISPLACEMENT (sorting,format_list,form,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format (.pch


file) or the OUTPUT2 format (.op2 file) output for normal
modes, frequency response, and transient subcases. It
will be ignored without warning if used elsewhere.

Default = blank

format

SORT1:

Results for each frequency/timestep are


grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment 7).

blank:

SORT1 is used for all results except for


transient analysis, where SORT2 is used.

<H3D, PUNCH,
H3D:
OP2, PLOT, blank>

Results are output in Hyper3D format


(.h3d file).

Default = blank

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 9).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST is
defined in the bulk data section.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

171

Argument

Options

Description
blank:

form

Results are output in all active formats


for which the result is available.

REAL, IMAG:

Provides rectangular format (real and


imaginary) of complex output.

PHASE:

Provides polar format (magnitude and


phase) of complex output. Phase
output is in degrees.

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will
be considered for this output.

<YES, ALL,
NO, NONE>

YES, ALL, blank:

Results are output.

Default = ALL

NO, NONE:

Results are not output.

<REAL, IMAG,
PHASE>
Default = REAL

peakoutput <PEAKOUT>
Default = blank

option

Comments
1.

When the SDISPLACEMENT command is not present, modal participation displacements are
not output.

2.

The SDISPLACEMENT command is only valid for modal frequency response and modal
transient solution sequences.

3.

The OFREQUENCY and OTIME I/O options may be used to control the amount of output.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous version of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

172

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

7.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

8.

The abbreviation SDISP is interchangeable with SDISPLACEMENT.

9.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

173

SENSITIVITY
I/O Options Entry
SENSITIVITY - Output Request
Description
The SENSITIVITY command can be used in the I/O Options section to request the output of
the responses and sensitivities for size and shape design variables to a Microsoft Excel
spreadsheet.
Format
SENSITIVITY = option

Argument

Options

Description

option

<YES, NO, ALL, NONE,


STRESS, NOSTRESS>

NO, NONE:

The results and sensitivities are not


output.

Default = NONE

YES,
NOSTRESS,
blank:

The results and sensitivities are


output excepting stress, strain, and
force responses.

ALL or
STRESS:

The results and sensitivities are


output including stress, strain, and
force responses.

Comments
1.

This command is ignored when OUTPUT, MSSENS command is present.

2.

When SENSITIVITY is not present, sensitivity information is not output.

3.

The frequency of this output is controlled by the SENSOUT option.

4.

For more details on the output format, go to the #.slk file page in the output section of
the Reference Guide.

5.

Additional sensitivity output requests for topology, free-sizing and gauge design variables
can be made through OUTPUT,H3DTOPOL and OUTPUT,H3DGAUGE (in H3D format), and
OUTPUT,ASCSENS (ASCII format).

174

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SENSOUT
I/O Options Entry
SENSOUT - Output Control
Description
The SENSOUT command can be used in the I/O Options section to control the frequency of
output of responses and sensitivities for size and shape design variables to a Microsoft Excel
spreadsheet.
Format
SENSOUT = frequency

Argument

Options

Description

frequency

<FIRST, LAST,
FL, ALL, N>

FIRST:

The results and sensitivities are output for the


first iteration only.

Default = FL

LAST:

The results and sensitivities are output for the


final iteration only.

FL,
blank:

The results and sensitivities are output for


both the first and last iterations.

ALL:

The results and sensitivities are output for all


iterations.

N:

The results and sensitivities are output for the


first and last iterations and for every Nth
iteration. If N = 5, output occurs for iterations
0, 5, 10, 15, 20, and so on, and the final
iteration. All equation and combination
responses are output.

Comments
1.

This command is ignored when OUTPUT, MSSENS command is present.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

175

SHAPE
I/O Options and Subcase Information Entry
SHAPE - Output Request
Description
The SHAPE command can be used in the I/O Options section to request altered shape output
for a shape optimization.
Format
SHAPE (format_list,type) = option

Argument Options

Description

format

HM:

Results are output in HyperMesh results


format (.res file).

H3D:

Results are output in Hyper3D format


(.h3d file).

blank:

Results are output in all active formats


for which the result is available.

ALL:

Results are output in all simulations.

DES,
blank:

Results are only output in the design


history simulations.

YES, ALL,
blank:

Results are output.

NO, NONE:

Results are not output.

<HM, H3D, blank>


Default = blank

type

<ALL, DES>
Default = DES

option

<YES, ALL, NO,


NONE>
Default = YES

Comments
1.

When the SHAPE command is not present, shape results are output.

2.

Shape results are only available for shape, topography, and free-shape optimizations.

176

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

Outputting the shape results in all simulations allows analysis results to be plotted on the
altered shape.

4.

The frequency of this output is controlled by the DESIGN keyword on an OUTPUT definition
or, if no OUTPUT definition exists with the DESIGN keyword, by the DENSRES I/O option.

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

6.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

177

SINTENS
I/O Options and Subcase Information Entry
SINTENS - Output Request
Description
The SINTENS command can be used in the I/O Options section to request Sound Intensity
output for all frequency response subcases. The SINTENS command can be used in the I/O
Options or Subcase Information sections to request Sound Intensity output for all subcases or
individual subcases respectively.
Format
SINTENS(type) = option

Argument Options

Description

type

PANEL,
blank:

Sound Intensity is output for both panels


and microphone locations.

NOPANEL:

Sound Intensity is output only for


microphone locations.

ALL,
blank:

Sound Intensity is output for all panel


grids and all grids defined as microphone
locations on the RADSND bulk data. In
addition, the total Sound Intensity for
each Panel and all the microphone
locations is output.

<PANEL, NOPANEL>
Default = PANEL

option

<ALL>
Default = ALL

Note: Sound Intensity is output only for


microphone locations if
type=NOPANEL is specified.
Comments
1.

When the SINTENS command is present, Sound Intensity is output for all RADSND panel
grids and all microphone grids for all frequency response subcases. (If type=NOPANEL is
specified, sound intensity results are output only for microphone locations).

2.

Sound Intensity results (via SINTENS) are output to the .h3d file.

3.

SINTENS can only be requested for frequency response subcases.

4.

Sound intensity is always output for microphone locations regardless of the specified type
(PANEL/NOPANEL).

178

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SPCFORCE
I/O Options and Subcase Information Entry
SPCFORCE - Output Request
Description
The SPCFORCE command can be used in the I/O Options or Subcase Information sections to
request single-point force of constraint vector output for all subcases or individual subcases
respectively.
Format
SPCFORCE (sorting,format_list,form,type,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format (.pch


file) or the OUTPUT2 format (.op2 file) output for
normal modes, frequency response, and transient
subcases. It will be ignored without warning if used
elsewhere.

Default = blank

format

<HM, H3D, OPTI,


PUNCH, OP2,
PLOT, blank>

SORT1:

Results for each frequency/timestep are


grouped together.

SORT2:

Results for each grid/element are grouped


together (See comment 10).

blank:

For frequency response analysis, if no grid


SET is specified, SORT1 is used, otherwise,
SORT2 is used.

HM:

Results are output in HyperMesh results


format (.res file).

H3D:

Results are output in Hyper3D format (.h3d


file).

OPTI:

Results are output in OptiStruct results


format (.spcf file).

PUNCH:

Results are output in Nastran punch results

Default = blank

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

179

Argument

Options

Description
format (.pch file).

form

<COMPLEX, REAL,
IMAG, PHASE,
BOTH>

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 11).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST is
defined in the bulk data section.

blank:

Results are output in all active formats for


which the result is available.

COMPLEX
(HM only),
blank:

Provides a combined magnitude/phase form


of complex output to the .res file for the
HM output format.

Default (HM only)


REAL,
= COMPLEX
IMAG:
Default (all other
formats) = REAL
PHASE:

type

<SPARSE, ALL>

Provides rectangular format (real and


imaginary) of complex output.
Provides polar format (magnitude and
phase) of complex output. Phase output is
in degrees.

BOTH (HM
only):

Provides both polar and rectangular formats


of complex output.

ALL:

Single-point force of constraint is output


for all selected nodes.

SPARSE:

Single-point force of constraint is output


only for selected nodes with a component
with a magnitude of 1.0E-10 or greater.

PEAKOUT:

If PEAKOUT is present, only the filtered


frequencies from the PEAKOUT card will be
considered for this output.

Default = SPARSE

peakoutput <PEAKOUT>
Default = blank

180

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

option

<YES, ALL, NO,


NONE, SID>

YES, ALL,
blank:

Single-point force of constraint is output


for all nodes.

NO, NONE:

Single-point force of constraint is not


output.

SID:

If a set ID is given, single-point force of


constraint is output only for nodes listed in
that set.

Default = ALL

Comments
1.

When an SPCFORCE command is not present, single-point force of constraint vector is not
output.

2.

Single-point force of constraint values are highly dependent on mesh density and type of
elements used.

3.

For modal frequency analysis, residual forces are zero only in modal space. Therefore,
the single-point force of constraint vector may not be accurate unless all modes are used
in the modal solution. When all possible modes in the model space are used, the modal
frequency analysis solution should match the direct frequency analysis solution.

4.

When single-point force of constraint is calculated, the reaction force summary, the load
summary, and the strain energy residuals for the affected subcases are written to the
.out file.

5.

The form argument is only applicable for frequency response analysis. It is ignored in
other instances.

6.

The forms BOTH and COMPLEX do not apply to the .frf output files.

7.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

8.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

9.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

181

10. In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.
11. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

182

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SPL
I/O Options and Subcase Information Entry
SPL - Output Request
Description
The SPL command can be used in the I/O Options or Subcase Information sections to request
Sound Pressure output for all subcases or individual subcases respectively. SPL can only be
requested for frequency response subcases.
Format
SPL = option

Argument Options

Description

option

ALL,
blank:

<ALL>
Default = ALL

Sound Pressure is output for all grids


defined as microphone locations on the
RADSND bulk data.

Comments
1.

When the SPL command is present, Sound Pressure is output for all microphone grids for
all frequency response subcases.

2.

Sound Pressure results (via SPL) are output to the .h3d file.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

183

SPOWER
I/O Options and Subcase Information Entry
SPOWER - Output Request
Description
The SPOWER command can be used in the I/O Options or Subcase Information sections to
request Sound Power output for all subcases or individual subcases respectively. SPOWER can
only be requested for frequency response subcases.
Format
SPOWER(type) = option

Argument Options

Description

type

PANEL,
blank:

Sound Power is output for both panels


and microphone locations.

NOPANEL:

Sound Power is output only for


microphone locations.

ALL,
blank:

Sound Power is output for all panel grids


and all grids defined as microphone
locations on the RADSND bulk data. In
addition, the total Sound Power for each
Panel and all the microphone locations is
output.

<PANEL, NOPANEL>
Default = PANEL

option

<ALL>
Default = ALL

Note:
Sound Power is output only for
microphone locations if type=NOPANEL is
specified.
Comments
1.

When the SPOWER command is present, Sound Power is output for all RADSND panel grids
and all microphone grids for all frequency response subcases. (If type=NOPANEL is
specified, sound power results are output only for microphone locations).

2.

Sound power is always output for microphone locations regardless of the specified type
(PANEL/NOPANEL).

3.

Sound Power results (via SPOWER) are output to the .h3d file.

184

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

STRAIN
I/O Options and Subcase Information Entry
STRAIN - Output Request
Description
The STRAIN command can be used in the I/O Options or Subcase Information sections to
request strain output for all subcases or individual subcases respectively.
Format
STRAIN
(sorting,format_list,form,type,location,extras_list,random,peakoutput,modal) =
option

Argument

Options

Descriptions

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format (.pch


file) or the OUTPUT2 format (.op2 file) output for
normal modes, frequency response, and transient
subcases. It will be ignored without warning if used
elsewhere.

Default = blank

format

<HM, H3D, OPTI,


PUNCH, OP2,
PLOT, blank>

SORT1:

Results for each frequency/timestep


are grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment 12).

blank:

For frequency response analysis, if no


element SET is specified, SORT1 is
used, otherwise, SORT2 is used; for
transient analysis, SORT2 is used.

HM:

Results are output in HyperMesh


results format (.res file). Refer to
Strain Results Written in HyperMesh
.res Format.

H3D:

Results are output in Hyper3D format


(.h3d file). Refer to Strain Results
Written in HyperView .h3d Format.

Default = blank

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

185

Argument

Options

Descriptions
OPTI:

Results are output in OptiStruct


results format (.strn file).

PUNCH:

Results are output in Nastran punch


results format (.pch file). Refer to
Strain Results Written in Nastran .op2
and .pch Formats.

OP2:

Results are output in Nastran output2


format (.op2 file) (see comment 15,
and also refer to Strain Results
Written in Nastran .op2 and .pch
Formats).

PLOT:

Results are output in Nastran output2


format (.op2 file) when PARAM, POST
is defined in the bulk data section.
Refer to Strain Results Written in
Nastran .op2 and .pch Formats.
If PARAM, POST is not defined in the
bulk data section, this format allows
the form for complex results to be
defined for XYPUNCH output without
having other output.

blank:

form

Results are output in all active


formats for which the result is
available.

<COMPLEX, REAL, COMPLEX (HM


IMAG, PHASE,
only), blank:
BOTH>

Provides a combined magnitude/phase


form of complex output to the .res
file for the HM output format.

Default (HM
only) = COMPLEX

Provides rectangular format (real and


imaginary) of complex output.

REAL or IMAG:

Default (all other PHASE:


formats) = REAL

Provides polar format (phase and


magnitude) of complex output.

BOTH (HM only): Provides both rectangular and polar


formats of complex output.

186

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Descriptions

type

<VON, PRINC,
MAXS, SHEAR,
ALL, TENSOR,
DIRECT>

VON:

Only von Mises strain results are


output.

PRINC, MAXS,
SHEAR:

von Mises and maximum principal


strain results are output.

ALL:

All strain results are output.

TENSOR:

All strain results are output. Tensor


format is used for H3D output.

DIRECT:

All strain results are output. Direct


format is used for H3D output.

<CENTER,
CENTER:
CUBIC, SGAGE,
CORNER, BILIN>

Element strains for shell and solid


elements are output at the element
center only.

Default = ALL

location

Default = CENTER

extras

<MECH, THER,
PLASTIC>

CUBIC:

Element strains for shell and solid


elements are output at the element
center and grid points using the
strain gage approach with cubic
bending correction.

SGAGE:

Element strains for shell and solid


elements are output at the element
center and grid points using the
strain gage approach.

CORNER or
BILIN:

Element strains for shell elements are


output at the element center and at
the grid points using bilinear
extrapolation. (see comment 11)

MECH:

Output Mechanical strain (in addition


to total strain). This output is only
available for H3D format.

No default

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

187

Argument

random

Options

Descriptions

<PSDF, RMS>

THER:

Output Thermal strain (in addition to


total strain). This output is only
available for H3D format.

PLASTIC:

Output Plastic strain (in addition to


total strain). This output is only
available for H3D format.

PSDF:

Requests PSD and RMS results from


random response analysis to be
output for solid and shell elements
only (See comment 13).

No default

Only valid for the H3D format. The


"RMS over Frequencies" output is at
the end of the Random results in the
.h3d file.
RMS:

Requests only the RMS over


Frequencies result from random
response analysis to be output for
solid and shell elements only (see
comment 13).
Valid only for the H3D format.

peakoutput <PEAKOUT>

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the PEAKOUT
card will be considered for this
output.

MODAL:

If MODAL is present, strain results of


the structural modes and residual
vectors are output to the PUNCH,
OUTPUT2 and H3D files for modal
frequency response and transient
analyses.

Default = blank

modal

<MODAL>
Default = blank

188

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Descriptions

option

<YES, ALL, NO,


NONE, SID,
PSID>

YES, ALL, blank:

Results are output for all elements.

NO, NONE:

Results are not output.

SID:

If a set ID is given, results are output


only for elements listed in that set.

PSID:

If a property set ID is given, results


for the elements referencing
properties listed in the property set
are output.

Default = ALL

Comments
1.

When the STRAIN command is not present, no strain data is output.

2.

HyperView can internally derive strain results from the strain tensor when the options
TENSOR or ALL are used. If the option DIRECT is used, it will display the strain results
that were directly computed.

3.

The von Mises and Principal stresses are not available for frequency response analysis.

4.

For elements that reference PCOMP and PCOMPG properties, the STRAIN I/O option controls
only strain results for the homogenized composite. The CSTRAIN I/O option must be used
to obtain ply strain results.

5.

The form argument is only applicable for frequency response analysis. It is ignored in
other instances.

6.

The forms BOTH and COMPLEX do not apply to the .frf output files.

7.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

8.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

9.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

10. The mechanical and thermal contributions to strain may be requested in addition to the
total strain.
11. Corner strain of solid element is not available.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

189

12. In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.
13. PSDF and RMS von Mises strain results based on the Segalman Method are also written to
the .h3d file for Random Response Analysis (only available in the H3D format).
14. The four-letter abbreviation STRA is interchangeable with STRAIN.
15. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

190

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

STRESS/ELSTRESS
I/O Options and Subcase Information Entry
STRESS - Output Request
Description
The STRESS command can be used in the I/O Options or Subcase Information sections to
request stress output for all subcases or individual subcases respectively.
Format
STRESS (sorting,format_list,form,type,location,random,peakoutput,modal) =
option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH


format (.pch file) or the OUTPUT2 format
(.op2 file) output for normal modes,
frequency response, and transient subcases.
It will be ignored without warning if used
elsewhere.

Default = blank

format

<HM, H3D, OPTI, PUNCH,


OP2, PATRAN, APATRAN,

Altair Engineering

SORT1:

Results for each frequency/


timestep are grouped
together.

SORT2:

Results for each grid/


element are grouped
together (see comment
12).

blank:

For normal modes analysis,


SORT1 is used; for
frequency response
analysis, if no element SET
is specified, SORT1 is used,
otherwise, SORT2 is used;
for transient analysis,
SORT2 is used.

HM:

Results are output in


HyperMesh results format
(.res file). Refer to Stress

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

191

Argument

Options

Description

PLOT, blank>

Results Written in
HyperMesh .res Format.

Default = blank
H3D:

Results are output in


Hyper3D format (.h3d file).
Refer to Stress Results
Written in HyperView .h3d
Format.

OPTI:

Results are output in


OptiStruct results format
(multiple files).

PUNCH:

Results are output in


Nastran punch results
format (.pch file). Refer
to Stress Results Written in
Nastran .op2 and .pch
formats.

OP2:

Results are output in


Nastran output2 format
(.op2 file) (see comment
15, and also refer to Stress
Results Written in Nastran
.op2 and .pch Formats).

PATRAN:

Results are output in


Patran format (multiple
files).

APATRAN:

Results are output in


Patran format (multiple
files).

PLOT:

Results are output in


Nastran output2 format
(.op2 file) when PARAM,
POST is defined in the bulk
data section. Refer to
Stress Results Written in
Nastran .op2 and .pch
Formats.
If PARAM, POST is not
defined in the bulk data
section, this format allows

192

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
the form for complex
results to be defined for
XYPUNCH output, without
having other output.

form

<COMPLEX, REAL, IMAG,


PHASE, BOTH>

blank:

Results are output in all


active formats for which
the result is available.

COMPLEX (HM
only), blank:

Provides a combined
magnitude/phase form of
complex output to the .res
file for the HM output
format.

REAL or IMAG:

Provides rectangular format


(real and imaginary) of
complex output.

PHASE:

Provides polar format


(phase and magnitude) of
complex output.

BOTH (HM
only):

Provides both rectangular


and polar formats of
complex output.

VON:

Only von Mises stress


results are output (HM,
OPTI, and H3D only).

PRINC, MAXS,
SHEAR:

von Mises and maximum


principal stress results are
output (HM and H3D only).

ALL:

All stress results are


output.

TENSOR:

All stress results are


output. Tensor format is
used for H3D output.

Default (HM only) =


COMPLEX
Default (all other formats)
= REAL

type

<VON, PRINC, MAXS, SHEAR,


ALL, TENSOR, DIRECT>
Default = ALL, TENSOR

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

193

Argument

location

Options

Description

<CENTER, CUBIC, SGAGE,


CORNER, BILIN>

DIRECT:

All stress results are


output. Direct format is
used for H3D output.

CENTER:

Element stresses for shell


and solid elements are
output at the element
center only.

CUBIC:

Element stresses for shell


elements are output at the
element center and grid
points using the strain
gage approach with cubic
bending correction.

SGAGE:

Element stresses for shell


elements are output at the
element center and grid
points using the strain
gage approach.

CORNER or
BILIN:

Element stresses for shell


and solid elements are
output at the element
center and grid points
using bilinear extrapolation.

PSDF:

Requests PSD and RMS


results from random
response analysis to be
output for solid and shell
elements only (See
comment 13).

Default = CENTER

random

<PSDF, RMS>
No default

Only valid for OUTPUT2 and


H3D formats. The "RMS
over Frequencies" output is
at the end of the Random
results in the .h3d file and
labeled "Simulation 1" in
the .op2 file.

194

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
Requests only the RMS
over Frequencies result
from random response
analysis to be output for
solid and shell elements
only (See comment 13).

RMS:

Valid only for OUTPUT2 and


H3D formats. It is labeled
Simulation 1 in the .op2
file.

peakoutput <PEAKOUT>

PEAKOUT:

If PEAKOUT is present, only


the filtered frequencies
from the PEAKOUT card will
be considered for this
output.

MODAL:

If MODAL is present,
stresses of the structural
modes and residual vectors
are output to the PUNCH
and OUTPUT2 files for modal
frequency response and
transient analysis.

Default = blank

modal

<MODAL>
Default = blank

option

<YES, ALL, NO, NONE, SID,


PSID>

YES, ALL, blank: Stress results are output


for all elements.

Default = ALL

NO, NONE:

Stress results are not


output.

SID:

If a set ID is given, stress


results are output only for
elements listed in that set.

PSID:

If a property set ID is
given, stress results for the
elements referencing
properties listed in the

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

195

Argument

Options

Description
property set are output.

Comments
1.

When a STRESS command is not present, stress results are output for all elements for all
linear static analysis, nonlinear quasi-static gap analysis, and inertia relief analysis
subcases.

2.

HyperView can internally derive STRESS results from the stress tensor when the options
TENSOR or ALL are used. If the option DIRECT is used, it will display the stress result that
were directly computed.

3.

For elements that reference PCOMP or PCOMPG properties, the STRESS I/O option controls
only stress results for the homogenized composite. The CSTRESS I/O option must be used
to obtain ply stress and failure index results.

4.

The Von Mises and Principal stresses are not available for frequency response analyses.

5.

The form argument is only applicable for frequency response analysis. It is ignored in
other instances.

6.

The forms BOTH and COMPLEX do not apply to the .frf output files.

7.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

8.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

9.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

10. For normal modes analysis output, if there is USET U6 data, the stresses for each residual
displacement vector associated with the USET U6 DOF are also output to the H3D, PUNCH,
and OUTPUT2 files.
11. For modal frequency response and transient analysis, the stress vectors associated with
the residual vectors are written to the .op2 and .pch files after the modal stress vectors
if the keyword MODAL is used.
12. In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

196

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

13. PSDF and RMS von Mises stress results based on the Segalman Method are also written to
the .h3d file for Random Response Analysis (only available in the H3D format).
14. The four-letter abbreviation STRE is interchangeable with STRESS.
15. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

197

SUBTITLE
I/O Options Entry
SUBTITLE - File Header
Description
The SUBTITLE command can be used in the I/O Options or Subcase Information sections to
define the subtitle for all subcases or for individual subcases respectively.
Format
SUBTITLE = name

Argument

Description

name

The subtitle for the subcase.


No default

Comments
1.

198

The subtitle is written to the output files.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SVELOCITY
I/O Options and Subcase Information Entry
SVELOCITY - Output Request
Description
The SVELOCITY command can be used in the I/O Options or Subcase Information sections to
request the form and type of modal participation velocities output for all subcases or individual
subcases respectively.
Format
SVELOCITY (sorting,format_list,form,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format


(.pch file) or the OUTPUT2 format (.op2 file)
output for normal modes, frequency response, and
transient subcases. It will be ignored without
warning if used elsewhere.

Default = blank

format

SORT1:

Results for each frequency/


timestep are grouped together.

SORT2:

Results for each grid/element are


grouped together (see comment
7).

blank:

SORT1 is used for all results


except for transient analysis,
where SORT2 is used.

<H3D, PUNCH, OP2,


PLOT, blank>

H3D:

Results are output in Hyper3D


format (.h3d file).

Default = blank

PUNCH:

Results are output in Nastran


punch results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 9).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

199

Argument

form

Options

Description
PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the
bulk data section.

blank:

Results are output in all active


formats for which the result is
available.

REAL, IMAG:

Provides rectangular format (real


and imaginary) of complex
output.

PHASE:

Provides polar format (magnitude


and phase) of complex output.
Phase output is in degrees.

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the
PEAKOUT card will be considered
for this output.

<YES, ALL,
NO, NONE>

YES, ALL, blank:

Results are output.

Default = YES

NO, NONE:

Results are not output.

<REAL, IMAG,
PHASE>
Default = REAL

peakoutput

<PEAKOUT>
Default = blank

option

Comments
1.

When the SVELOCITY command is not present, modal participation velocities are not
output.

2.

The SVELOCITY command is only valid for modal frequency response and modal transient
solution sequences.

3.

The OFREQUENCY and OTIME I/O Options may be used to control the amount of output.

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

200

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

6.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

7.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

8.

The abbreviation SVELO is interchangeable with SVELOCITY.

9.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

201

SYSSETTING
I/O Options Entry
SYSSETTING Run Control
Description
The SYSSETTING command can be used in the I/O Options section to alter system settings.
Any setting defined here may be over-ridden by command line arguments (see Run Options for
OptiStruct). Most of these options can also be specified in one of the config files (see
OptiStruct Configuration File).
Format
SYSSETTING(setting=option_list,setting=option_list,)
Examples
SYSSETTING(RAMDISK=100)
SYSSETTING(SCRFMODE=buffered,stripe)
SYSSETTING(SPSYNTAX=mixed,RAMDISK=100,SCRFMODE=buffered,stripe,OS_RAM=1234)

Setting

Options

Description

BARPROP

<STRICT, MIXED>

STRICT: The CBAR and CBEAM beam element


connections cannot reference the PBEAM beam
property entries, respectively.

Default = STRICT

MIXED: The CBAR and CBEAM beam element


connections can reference the PBEAM and PBAR
beam property entries, respectively.
BUFFSIZE

BUFFSIZE = 16832

The maximum size in 8 byte words of the records of


data written to the .op2 file. Use -1 to turn off
buffering.

CARDLENGTH

<Integer>

Defines the number of characters read on a single


line in the I/O Options and Subcase Information
sections. This can vary between 80 and 132
characters.

Default = 80

In the Bulk Data section, CARDLENGTH applies to


free and long free format lines only (fixed and long
format lines are always limited to 72 characters).

202

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Setting

Options

Description

DUPTOL

Integer <0-5>

Controls accuracy used during elimination of


potential duplicate cards. Two cards with identical
ID's are replaced by the first one, if all integer
values on both cards match exactly, and all float
values match with accuracy controlled by this
setting, otherwise identical IDs are flagged as
ERROR. Currently only GRID, CORDxx, and base
MAT/PROP entry duplicates are allowed (MATX,
MATT, and PROPX entries do not allow duplicates).

Default = 0

0: no tolerance, the values defined must be an


exact match.
1: for standard fixed 8-character without
exponent, the value must match up to 6 decimal
places.
2: for standard fixed 8-character without
exponent, the value must match up to 5 decimal
places.
3: for standard fixed 8-character without
exponent, the value must match up to 4 decimal
places.
4: for standard fixed 8-character without
exponent, the value must match up to 3 decimal
places.
5: for standard fixed 8-character without
exponent, the value must match up to just 2
decimal places.
If values are too large or too small to represent
without exponent, then both values must match
exactly when converted to 8-character form. Also,
for negative values, the accuracy is one digit
lower.
H3DVTAG

<YES, NO>
Default = NO

Appends the version of the H3D format used, onto


the .h3d file output by OptiStruct.
So the results file would then be
{filename}.h3d11 or {filename}.h3d12.
Note: It is not possible to select the H3D format
used for output; this is built into the
executable.

MAXLEN

<Integer>

Altair Engineering

Used to define the maximum allowable amount of

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

203

Setting

Options

Description
memory to be used in MB. There is no default.
MAXLEN is not supported when the MUMPS solver
is used (including ddm parallel runs).

MINLEN

<Integer>

NPROC
<Integer>
(legacy
command: CPU) Default = 1
OS_RAM

<RAM in Mbytes>
Default = 1Gbyte

PLOTELID

Used to define the initial memory allocation in MB.


The default is 10% of OS_RAM. This is the same
as the legacy command, OS_RAM_INIT.
Same as nproc and -cpu options (see Run
Options for OptiStruct). Sets number of
processors in a multiprocessor (SMP) run.
Memory limit in Mb. The solver will attempt to run
at least the minimum core solution regardless of
the memory limit. See Memory Limititations in the
Users Guide for details.

<UNIQUE, ALLOWFIX>

Controls the numbering scheme of the PLOTEL ID.

Default = UNIQUE

UNIQUE requires all PLOTEL elements have unique


element IDs.
ALLOWFIX allows OptiStruct to automatically fix ID
collisions for PLOTEL. If PLOTEL elements have the
same IDs as some other elements, OptiStruct
renumbers the IDs of all PLOTEL by adding a large
offset value.

RAM_SAFETY

Same as -rsf option. (see Run Options for


OptiStruct).

<Real>
Default = 1.0

Specifies an area in RAM allocated to store


information which otherwise would be stored in
Default = See comment scratch files on the hard drive.
5
See comment 5 below for more details.

RAMDISK

<RAM in Mbytes>

SAVEFILE

SAVEFILE = OUT

SAVEFILE controls the behavior of the solver when


an output file with the same name already exists
when the program starts.
SAVEFILE = ALL will prevent overwriting output

204

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Setting

Options

Description
files by renaming an existing file by adding numeric
suffix, for example, jobname.h3d will be renamed
to jobname_nnn.h3d where nnn represents the
smallest number for file which does not exists yet.
This option tries to preserve files with all known
extensions, and it may use a large amount of disk
space if the same run is repeated multiple times.
SAVEFILE = OUT (default) will preserve only .out
and .stat files.
SAVEFILE = NONE will allow the solver to overwrite
any existing file.
SAVEFILE = ext, where ext is arbitrary file
extension (case insensitive, up to 9 characters).
See comments 8 and 9.

SCRFMODE

Allows for the selection of different modes of


storing scratch files for a linear solver process
(especially for out-of-core and minimum-core
Primary options: BASIC, modes).
BUFFERED, UNBUFFER,
BASIC: FORTRAN mode, direct access file.
STRIPE
<primary_option,
secondary_option>

Secondary option:
MIXFCIO

BUFFERED: FORTRAN buffered.


UNBUFFER: C i/o mode (default).

Default =
1. For Linux: UNBUFFER
2. For Windows
(without AMSES):
BUFFERED, MIXFCIO
3. For Windows (using
AMSES): BASIC
SKIP10FIELD

<CHECK, WARN>
Default = CHECK

Altair Engineering

STRIPE: Stripe main solver files on multiple disks


(except ones marked as slow).
MIXFCIO (only valid when combined with
BUFFERED): Use C (native) I/O routines instead of
FORTRAN read/write for main solver files.
See comment 7 below for more details.
To detect disallowed use of potential expansion of
free format, error will be generated when 10 or
more data fields is found on a bulk data card in free
format. Use SKIP10FIELD=WARN to allow reading
such card (extra fields will be disregarded instead
of causing error).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

205

Setting

Options

Description

SPSYNTAX

<STRICT, CHECK,
MIXED>

Controls how strict the checks are in the reader for


mixing GRIDs and SPOINTs.

Default = CHECK

STRICT: When both grid/component pairs (G#/C#)


and grid lists for a given component (as on the
alternate formats ASET1 and USET1 bulk data
entries) are defined, this option will require that
the component be 0 or blank when the grid
reference is a scalar point (SPOINT), and that the
component be > 1 when the grid reference is a
structural grid point (GRID).
CHECK: When grid/component pairs (G#/C#) are
defined, this option will require that the component
be 0 or blank when the grid reference is a scalar
point (SPOINT), and that the component be > 1
when the grid reference is a structural grid point
(GRID). But when grid lists for a given component
(as on alternate formats ASET1 and USET1 bulk
data entries) are defined, this option will allow the
grid reference to be scalar points (SPOINT) or
structural grid points (GRID) when the component
is 0, 1 or blank; interpreting all of these as 0 for
scalar points and as 1 for structural grids.
MIXED: When grid/component pairs (G#/C#) and
grid lists for a given component (as on alternate
formats ASET1 and USET1 bulk data entries) are
defined, this option will allow the grid reference to
be scalar points (SPOINT) or structural grid points
(GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and
as 1 for structural grids.
See comment 6 below for more details.

SYNTAX

<ALLOWINT, STRICT>

Controls how strict the syntax checker in the


reader is.

Default = ALLOWINT
ALLOWINT is the default setting for OptiStruct, and
converts integer values to real values whenever
real values are expected. In those instances,
where the form of the input (Integer or Real)
indicates the nature of the input (for example,
when reading vector entries (X,Y,Z) with alternate
form (GID, , )), a negative integer value in the first
field, or a non-blank value in the second or third
field indicates the (X,Y,Z) format and all fields are

206

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Setting

Options

Description
read as real values.
STRICT follows more closely with other Nastran
codes, where integer values may only be entered in
integer value fields and real values must be entered
in real value fields. An error termination will occur
if an integer value is placed in a real value field
when this setting is chosen.
Note: This setting never changes results it can
only cause the rejection of files that do not
follow the restrictions.

TABSTOPS

UNDEFTEMP

TABSTOPS = 8

<STRICT, ZERO>

TABSTOPS allows you to change interpretation of


TAB character in the input. By default TAB stops
are spaced by 8 columns, which is standard on all
Unix/Linux terminals. Possible values are 4 (used
often on Windows) and 1 (replace each TAB with
exactly one space).
STRICT

OptiStruct will error out if there


are some grid points without a
specified temperature (that is, a
minimum of one, but not all, grid
points in the model has a specified
temperature). The error message
includes information about GRID ID,
Element ID, and Load Set number.

ZERO

OptiStruct will use a value of zero


for grids without a specified
temperature (that is, a minimum of
one, but not all, grid points in the
model has a specified
temperature). This allows users to
revert to the behavior of versions
prior to OptiStruct 13.0.

Default = STRICT

UPDATE

UPDATE option
(quiet, verbose,
strict, off, unique,
permissive)

Controls the behavior of


ASSIGN,UPDATE,<filename>.
quiet

Less output (default).

Defaults = quiet and


strict

verbose

More output including old and new


values.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

207

Setting

Options

Description
strict

Do not allow non-supported cards


in update deck (default).

off

Disable update.

unique

Each ID only once.

permissive

Allow all cards and repeat IDs.

Choose only one option from: quiet, verbose.


Choose only one option from: strict, off,
unique, permissive.
USERAM

<RAM in Mbytes>

Memory limit in Mb. The solver will use more than


the minimum memory required up to this limit, but
only if it improves the speed of the solution. See
Memory Limitations in the Users Guide for details.

Comments
1.

The number of fields in this card is not limited to 10, but it is limited by the current line
length (default 80).

2.

Continuation lines are not allowed, multiple SYSSETTING cards are allowed.

3.

The settings CPU and NPROC are interchangeable, and can also be specified on the
command line.

4.

Each option except SCRFMODE must have exactly one argument. SCRFMODE arguments
should be comma separated.

5.

For RAMDISK setting:


a) Use of a virtual disk instead of physical files may speed up solutions by reducing wait
time to access physical disk drives. Note that the use of RAMDISK will reduce the
amount of memory available for the solver and for file buffering performed by the
operating system (by Linux or Windows), and because of that it may not always
reduce the wall clock time for the solution. The most impact can be observed on
machines with very large physical memory (20GB or more) or when used to speed-up
main solver scratch file access using the SCRFMODE setting.
b) RAMDISK is automatically protected for overflow, so it is fine to specify 200MB for
RAMDISK when the total amount of scratch files will be larger than that.
c) RAMDISK is automatically specified for very small jobs, (less than 10,000 GRIDS). This
can be disabled by specifying RAMDISK=0. Automatic RAMDISK is not allocated for
fixed RAM jobs (the -fixlen command line option is used, see Run Options for
OptiStruct).

6.

208

For SPSYNTAX setting:

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

a) When the component from a grid/component pair or for a list of grids (as on alternate
formats ASET1 and USET1 bulk data entries) is greater than 1, the grid reference must
always be a structural grid (GRID).
b) This control may also be set in the OptiStruct Configuration File.
7.

For SCRFMODE setting:


a) This command controls the way scratch files from the linear equation solver are written
to the disk. These files are usually written and read several times, often in random
pattern, and this can have a significant impact on the total (wall clock) time for the
solution of large jobs. The default mode is optimal in most configurations, but choosing
between BASIC, BUFFERED or UNBUFFER may improve speed for some hardware and/or
some types of solution sequences, especially jobs including Lanczos eigenvalue solver.
b) In out-of-core and minimum-core solver modes, the solver creates one large scratch
file for each subcase and this file may be optionally located across multiple TMPDIRs.
In order to use this capability, SCRFMODE=STRIPE must be defined, otherwise the same
method as for other files (BASIC, BUFFERED or UNBUFFER) is used, and this large file
must therefore fit on a single TMPDIR.
c) STRIPE mode can be used when all TMPDIRs (not marked as SLOW) are fully
independent (that is, they should not be partitions on the same physical drive). This
mode results in the access to all disks similar to RAID0 - consecutive blocks of data
are split between separate TMPDIRs, and accessed in parallel, which can speed up disk
access considerably.
Warning: Using STRIPE with TMPDIRs allocated on the
same physical drive (even on different
partitions) will usually slow down the solution by
increasing wait times. Check with your system
administrator for information on the actual
hardware structure of your computer.
d) STRIPE requires multiple TMPDIR cards and has effect only for out-of-core or minimumcore solutions.
e) Most modern operating systems (Linux in particular) use excess available RAM for the
buffering of disk i/o. The SCRFMODE command will have effect only for jobs which
exceed the capabilities of this buffer.
f) When AMSES is used on Windows, BASIC mode is enforced during AMSES calculations.
g) The scrfmode option can be specified on the command line (see Run Options for
OptiStruct) this overrides any information specified in the input file.

8.

The SAVEFILE option tries to preserve only files in the start directory, that is, this option
has no effect when the input file is specified with a path, or the OUTFILE option defines a
different location for all output files. Unless SAVEFILE,NONE is specified, standard .out
and .stat files are always renumbered, even if they are created in different folder. All
files are renumbered at program start .out file is preserved first, and then the same
NNN is used for all files found in the current folder. Only files with default names are
preserved (that is those starting with the same root as outfile). Note that this option
may sometimes cause the solver to fail if it renames the file which is intended for the
input.

9.

Multiple SAVEFILE cards overwrite each other (the last one is in effect). Multiple
SAVEFILE,ext cards can be used (up to 5 extensions can be defined), but using of any of
the standard options (NONE/ALL/OUT) empties the list of previously defined extensions.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

209

TCURVE
I/O Options Entry
TCURVE Output Request
Description
The TCURVE command can be used in the I/O Options section to define the plot title for
XYPLOT output from a random response analysis.
Format
TCURVE = title

Argument

Description

title

Character string.
Default = A default title is provided.

Comments
1.

TCURVE may not be continued onto the next line.

2.

A TCURVE definition applies to all plots defined after TCURVE until another definition of
TCURVE occurs.
Example:
XTITLE = X-A
YTITLE = Y-A
XYPLOT (first plot definition)
YTITLE = Y-B
TCURVE = C-A
XYPLOT (second plot definition)
would assign X-A, Y-A and the default plot title to the first plot, then X-A, Y-B and C-A
to the second plot.

210

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

THERMAL
I/O Options and Subcase Information Entry
THERMAL Output Request
Description
The THERMAL command can be used in the I/O Options or Subcase Information sections to
request temperature output for all heat transfer analysis subcases or individual heat transfer
analysis subcases respectively.
Format
THERMAL (format_list) = option

Argument

Options

Description

format

<PUNCH,
OP2, PLOT,
H3D, blank>

PUNCH:

Results are output in Nastran punch results


format (.pch file).

Default =
blank

OP2:

Results are output in Nastran output2 format


(.op2 file) (see comment 7).

PLOT:

Results are output in Nastran output2 format


(.op2 file) when PARAM, POST is defined in the
bulk data section.

H3D:

Results are output in Hyper3D format (.h3d


file).

blank:

Results are output in all active formats for


which the result is available.

<YES, ALL,
NO, NONE,
SID>

YES, ALL,
blank:

Thermal results are output at all grid points


for which temperature results are available.

Default = ALL

NO, NONE:

Thermal results are not output

SID:

If a set ID is specified, Thermal results are


output only for grid points referenced by that
set.

option

Comments
1.

When the THERMAL command is not present, thermal results are not output.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

211

2.

Thermal output is only available for the heat transfer analysis solution sequence.

3.

The PUNCH output produces TEMP bulk data entries, and the SID on the entries will be the
subcase number (=1 if no SUBCASES are specified).

4.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
the results available and their respective formats.

5.

Temperature output via the THERMAL output request is available for both linear steady
state heat transfer and linear transient heat transfer analyses.

6.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

7.

format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

212

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

THICKNESS
I/O Options and Subcase Information Entry
THICKNESS - Output Request
Description
The THICKNESS command can be used in the I/O Options section to request thickness output
for elements referencing a PSHELL or PCOMP property in:
Size/Free-size optimization
Analysis runs
Topology optimization
Format
THICKNESS (format_list, comp) = option

Argument

Options

Description

format

<HM, H3D, blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

blank:

Results are output in all active


formats for which the result is
available. (See comments 1 and
2)

<ALL, DESIGN,
NOPLY>

ALL:

Thickness results are output for


all plies.

Default = DESIGN

DESIGN, blank:

Thickness results are output for


designable plies only.

NOPLY:

No ply thickness results are


output.

Default = blank

comp

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

213

Argument

Options

Description

option

<YES, ALL, NO, NONE>

YES, ALL, blank:

Thickness results are output

NO, NONE:

Thickness results are not output.

Default = YES

Comments
1.

When the THICKNESS command is not present, thickness results are output. THICKNESS
results for analysis runs, however, are not output by default and will be output only if
the THICKNESS data entry is present in the solver deck.

2.

Thickness results are available for analysis runs, size/free-size optimization, and topology
optimization only.

3.

When thickness results are output to the .h3d file, percentage thickness change is also
output.

4.

Outputting the density results in all simulations allows analysis results to be plotted on
the density iso-surface in HyperView.

5.

The frequency of this output is controlled by the DESIGN keyword on an OUTPUT definition
or, if no OUTPUT definition exists with the DESIGN keyword, by the DENSRES I/O option.

6.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

7.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

214

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

THIN
I/O Options and Subcase Information Entry
THIN - Output Request for Geometric Nonlinear Analysis Subcase
Description
The THIN command can be used in the I/O Options or Subcase Information sections to
request thinning and thickness output for all geometric nonlinear analysis subcases or
individual geometric nonlinear analysis subcases respectively.
Format
THIN (format, type) = option

Argument Options

Description

format

H3D:

Results are output in Hyper3D


format (.h3d file).

blank:

Results are output in all active


formats for which the result is
available.

ALL:

Thinning and thickness results


are output.

THIN:

Percentage element thinning only


is output.

THICK:

Element thickness only is output.

<YES, ALL, NO, NONE,


SID, PSID>

YES, ALL, blank:

Thinning/thickness are output for


all elements.

Default = ALL

NO, NONE:

Thinning/thickness are not


output.

SID:

If a set ID is given, thinning/


thickness are output only for
elements listed in that set.

<H3D, blank>
Default = blank

type

<ALL, THIN, THICK>


Default = ALL

option

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

215

Argument Options

Description
PSID:

If a property set ID is given,


thinning/thickness results for the
elements referencing properties
listed in the property set are
output.

Comments
1.

THIN is only applicable for geometric nonlinear analysis subcases which are defined by an
ANALYSIS = NLGEOM subcase entry.

2.

Only formats that have been activated by an OUTPUT or FORMAT statement are valid for
use on this card.

3.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

4.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

216

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TITLE
I/O Options Entry
TITLE - File Header
Description
The TITLE command can be used in the I/O Options section to define the title for the
OptiStruct job.
Format
TITLE = name

Argument

Description

name

The title for the job.


No default

Comments
1.

The title is printed into the output and results files.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

217

TMPDIR
I/O Options Entry
TMPDIR - Directory Selection
Description
The TMPDIR command is used in the I/O Options section to choose the directory in which the
scratch files are to be written.
Format
TMPDIR = <options> path

Argument

Options

Description

options

-FILESIZE=n

Maximum allowable file size in GB.

SLOW=1

Non-zero value denotes a network drive.

path

<directory path> The path to the directory where scratch files are to be
written.
Default = ./

Examples
Windows Operating System
Local Drive
TMPDIR = -FILESIZE=13 D:\Dir1\Dir2\...\DirN\Scratch
TMPDIR = -FILESIZE=13 D:\Dir1\Dir2\...\DirN\Scratch Files
Network Drive
1.

Map the network drive (drive on a remote machine) to a drive (Y:\) on your computer.

2.

Use the path to your preferred scratch directory on the mapped network drive as the
path argument for TMPDIR.
TMPDIR = -FILESIZE=13 SLOW=1 Y:\Scratch
TMPDIR = -FILESIZE=13 SLOW=1 Y:\Scratch Files

218

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Linux Operating System


Local Drive
TMPDIR = -FILESIZE=13 /Dir1/Dir2/.../DirN/Scratch
TMPDIR = -FILESIZE=13 D:/Dir1/Dir2/.../DirN/Scratch Files
Comments
1.

The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

2.

Multiple TMPDIR cards are allowed (up to five entries). Scratch files will be allocated in all
directories depending on the options defined (see comments 3 through 8).

3.

Before opening any scratch file during the solution process, the solver checks the
available free space on all TMPDIRs and allocates that file on the directory which has most
free space. This algorithm tends to spread disk usage between different directories, but
does not guarantee full usage of each TMPDIR area.

4.

The main scratch file used during a linear solver process (that is solution of linear system
or eigen problem) can be split between multiple TMPDIRs (see SCRFMODE).

5.

When TMPDIR is marked as SLOW, it is used only after other TMPDIRs are filled up.
Selecting directories for TMPDIR on disk drives shared across the network (that is on
different computers or on centralized file servers) is not recommended, and should be
avoided if possible. Some scratch files (especially for out-of-core and minimum-core
mode) are heavily used, and accessing them across the network will dramatically increase
wall clock time for the solution. The main purpose of the TMPDIR command is to avoid
this delay when work areas (home directories) are allocated on a central server, as is
customary at many large organizations. All scratch files are stored in the specified
directories. The scratch files are automatically removed at the end of the analysis unless
there is a system error or core dump (in which case, the scratch file may need to be
cleaned up manually).

6.

See the SCRFMODE setting on the SYSSETTING I/O option for an additional way to use
multiple TMPDIR cards for large jobs.

7.

The tmpdir option can be specified on the command line (see Run Options for
OptiStruct); this overrides any information specified in the input file.

8.

The filesize option is needed in rare cases when there is a file size limit imposed by
operating system. This limit is large enough for all practical problems in most cases. The
following cases are known to have a file size limit of 2GB:
FAT32 file system (Windows, sometimes Linux)
ext2 file system (older Linux distributions)
NFS version 2
It is recommended to upgrade hardware and/or operating system in these cases.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

219

220

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TTERM
I/O Options and Subcase Information Entry
TTERM - Termination Time for Geometric Nonlinear Analysis Subcase
Description
The TTERM command can be used in a geometric nonlinear subcase to define the termination
time.
Format
TTERM = value

Argument

Description

value

Termination time for a geometric nonlinear subcase.


Default = 1.0 (Real)

Comments
1.

TTERM is only allowed in geometric nonlinear subcases which are defined by an ANALYSIS
= NLGEOM, IMPDYN, or EXPDYN subcase entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

221

UNITS
I/O Options Entry
UNITS - Unit System for the Model
Description
The UNITS command can be used in the I/O Options section to define a system of units for
the model.
Format
UNITS = system

Argument

Options

Description

system

<SI, CGS, MPA,


BG>

SI:

International system of units.


Length: meter = m
Mass: kilogram = kg

No default

Time: second = s
Temperature: Kelvin = K
Pressure - Pa
CGS:

Centimeter-gram-second system of units.


Length: centimeter = cm
Mass: gram = g
Time: second = s
Temperature: Kelvin = K
Pressure = barye = 0.1 Pa

MPA:

Mega
Length: millimeter = mm
Mass: tonne = tonne
Time: second = s
Temperature: Kelvin = K
Pressure - MPa

BG:

British Gravitational system of units.


Length: feet = ft
Mass: slug = slug
Time: second = s
Temperature: Rankine = R

222

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
Pressure = Ibf/ft 2

Comments
1.

Only one instance of this card is supported. If multiple instances are defined, the last
occurrence will be used.

2.

This UNITS data entry is the same as the DTI,UNITS entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

223

VELOCITY
I/O Options and Subcase Information Entry
VELOCITY - Output Request
Description
The VELOCITY command can be used in the I/O Options or Subcase Information sections to
request velocity vector output for all subcases or individual subcases respectively.
Format
VELOCITY(sorting,format,form,rotations,random,peakoutput) = option

Argument

Options

Description

sorting

<SORT1, SORT2>

This argument only applies to the PUNCH format


(.pch file) or the OUTPUT2 format (.op2 file)
output for normal modes, frequency response, and
transient subcases. It will be ignored without
warning if used elsewhere.

Default = blank

format

<HM, H3D, OPTI,


PUNCH, OP2, HG,
PLOT, blank>

SORT1:

Results for each frequency/


timestep are grouped together.

SORT2:

Results for each grid/element are


grouped together (See comment
8).

blank:

For frequency response analysis,


if no grid SET is specified, SORT1 is
used, otherwise, SORT2 is used;
for transient analysis, SORT2 is
used.

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in OptiStruct


results format (.disp file).

Default = blank

224

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
PUNCH:

Results are output in Nastran


punch results format (.pch file).

OP2:

Results are output in Nastran


output2 format (.op2 file) (see
comment 11).

HG:

Results are output in HyperGraph


presentation format (_freq.mvw
file and _tran.mvw file) see
OUTPUT keywords HGFREQ and
HGTRANS.

PLOT:

Results are output in Nastran


output2 format (.op2 file) when
PARAM, POST is defined in the
bulk data section.
If PARAM, POST is not defined in
the bulk data section, this
format allows the form for
complex results to be defined for
XYPUNCH output without having
other output.

form

<COMPLEX, REAL,
IMAG, PHASE,
BOTH>
Default (HM only)
= COMPLEX

blank:

Results are output in all active


formats for which the result is
available.

COMPLEX (HM
only), blank:

Provides a combined magnitude/


phase form of complex output to
the .res file for the HM output
format.

REAL or IMAG:

Provides rectangular format (real


and imaginary) of complex
output (See comment 9).

PHASE:

Provides polar format (magnitude


and phase) of complex output.
Phase output is in degrees (See
comment 9).

Default (all other


formats) = REAL

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

225

Argument

rotations

Options

Description

<ROTA, NOROTA>

BOTH (HM only):

Provides both polar and


rectangular formats of complex
output.

ROTA:

Requests output of rotational


velocity results (in addition to
rotational velocity results).

NOROTA:

Rotational velocity results are


not output.

PSDF:

Requests PSD and RMS results


from random response analysis
to be output.

Default = NOROTA

random

<PSDF, RMS>
No default

Only valid for the H3D format.


The "RMS over Frequencies"
output is at the end of the
Random results.
RMS:

Requests only the RMS over


Frequencies result from random
response analysis to be output.
Valid only for the H3D format.

peakoutput

PEAKOUT:

If PEAKOUT is present, only the


filtered frequencies from the
PEAKOUT card will be considered
for this output.

<YES, ALL, NO,


NONE, SID>

YES, ALL, blank:

Velocity is output for all nodes.

Default = YES

NO, NONE:

Velocity is not output.

<PEAKOUT>
Default = blank

option

226

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
SID:

If a set ID is given, velocity is


output only for nodes listed in
that set.

Comments
1.

When the VELOCITY command is not present, velocity vector is not output.

2.

Velocity output is available for frequency response and transient analysis solution
sequences.

3.

The form argument is only applicable for frequency response analysis. It is ignored for
other analysis types.

4.

The forms BOTH and COMPLEX do not apply to the .frf output files.

5.

Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

6.

Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.

7.

For optimization, the frequency of output to a given format is controlled by the I/O
option OUTPUT. In previous versions of OptiStruct, a combination of the I/O options
FORMAT and RESULTS were used; this method is still supported, but not recommended as it
does not allow different frequencies for different formats.

8.

In general, HyperView does not recognize the SORT2 format for results from the .op2 file.
When results are output only in SORT2 format (<Result Keyword> (SORT2, OUTPUT2,
.)), the results are written by OptiStruct into the .op2 file in SORT2 format, but when
the .op2 file is imported into HyperView, the results in SORT2 format are not recognized.
Therefore, the SORT1 option is recommended for results output in OUTPUT2 format and
SORT2 option is recommended for results output in PUNCH format.

9.

Results in binary format (.h3d or .op2) are always output in PHASE/MAG form, regardless
of the options specified in the FORM field. The corresponding post-processors
(HyperView/HyperGraph) can easily convert the PHASE/MAG format to the required
formats. Results in ASCII formats are output in the specified/requested FORM.

10. The four-letter abbreviation VELO is interchangeable with VELOCITY.


11. format=OUTPUT2 can also be used to request results to be output in the Nastran output2
format (.op2 file).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

227

XTITLE
I/O Options Entry
XTITLE Output Request
Description
The XTITLE command can be used in the I/O Options section to define the x-axis label for
XYPUNCH or XYPLOT output from a random response analysis.
Format
XTITLE = title

Argument

Description

title

Character string.
Default = blank

Comments
1.

XTITLE may not be continued onto the next line.

2.

An XTITLE definition applies to all plots defined after XTITLE until another definition of
XTITLE occurs.
Example:
XTITLE = X-A
YTITLE = Y-A
XYPLOT (first plot definition)
YTITLE = Y-B
TCURVE = C-A
XYPLOT (second plot definition)
would assign X-A, Y-A and the default plot title to the first plot, then X-A, Y-B, and C-A
to the second plot.

228

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

XYPEAK / XYPLOT / XYPUNCH


I/O Options Entry
XYPEAK - Output Request
XYPLOT - Output Request
XYPUNCH - Output Request
Description
The XYPEAK, XYPLOT, and XYPUNCH commands can be used in the I/O Options section to
request output from a random response analysis. The XYPUNCH command can also be used
with the RESPONSE plot-type to request .pch file output from a frequency response analysis.
Format
operation, curve-type, plot-type / entity ID(item code) list

Argument

Options

Description

operation

<XYPEAK,
XYPLOT,
XYPUNCH>

XYPEAK:

Generates a .peak file containing a summary of the


requested output for random response analysis.

XYPLOT:

Generates a HyperGraph session file and related


data files for the requested output for random
response analysis.

No default

XYPUNCH: Generates a .pch file for the requested output for


random response analysis.
With the plot-type RESPONSE, this command can
also be used to generate .pch file output for
frequency response analysis.

curve-type

<DISP, VELO, DISP:

Requests output for displacement.

ACCE, FORCE,
VELO:
STRESS,
STRAIN>
ACCE:
No default

Requests output for velocity.

FORCE:

Requests output for acceleration.


Requests output for force.
For plot-type RESPONSE:
CBUSH and CELAS elements only.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

229

Argument

Options

Description
For plot-type PSDF:
CBUSH, CVISC, CDAMP, and CELAS elements only.
STRESS:

Requests output for element stress.


For plot-types PSDF and AUTO.

STRAIN:

Requests output for element strain.


For plot-types PSDF and AUTO.

plot-type

<PSDF, AUTO, PSDF:


RESPONSE>
No default
AUTO:

Requests power spectral density function for


random response analysis. (see comment 5)

Requests autocorrelation for random response


analysis.

RESPONSE: Requests time or frequency in SORT2 format or


grid identification numbers in SORT1 format.
RESPONSE is only supported for the XYPUNCH
operation for frequency response analysis.

entity ID (item List of grid or GRID:


code) list
element,
component
pairs.
The list must
come after a
slash "/".
Each entry in
the list is
comma
separated.
No default

Each entry consists of a GRID or SPOINT ID


followed by a component of motion (T1, T2, T3,
R1, R2, or R3) in parentheses. In the components
of motion, T signifies translation and R signifies
rotation while the numbers indicate the
translational direction or rotational axis.
For frequency response analyses, the
components of motion are T1RM, T2RM, T3RM,
T1IP, T2IP, T3IP, R1RM, R2RM, R3RM, R1IP, R2IP,
and R3IP, where RM signifies Real or Magnitude
and IP signifies Imaginary or Phase. The type of
the response depends on a preceding output
request.
For SPOINTs, the component must be T1, T1RM,
or T1IP.

230

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
ELEMENT:

For elements, the item code (number code only)


represents a component of the element stress/
strain, which is described in DRESP1 Frequency
Response Stress/Strain Item Codes and DRESP1
_Frequency Response Force Item Codes

Examples
XYPLOT, XYPEAK, VELO, PSDF / 3(T2), 6(T2)
XYPEAK, DISP, AUTO / 223(T3)
XYPEAK, XYPLOT, XYPUNCH, ACCE, PSDF / 8(T1), 9(T1), 8(T2), 9(T2)
Comments
1.

Unlike other output requests, XYPEAK, XYPLOT, and XYPUNCH may be combined on a single
line (as shown in the example above).

2.

If the XYPEAK, XYPLOT, or XYPUNCH commands are not supplied, then no random response
results will be output.

3.

If the XYPEAK, XYPLOT, or XYPUNCH commands are supplied, but with an incomplete
definition, an error termination will occur.

4.

For complex results, the format of XYPUNCH output (Real/Imaginary or Phase/Magnitude) is


determined by the relevant result output request (ACCELERATION, DISPLACEMENT,
STRESS, STRAIN, FORCE or VELOCITY). Real/Imaginary is the default if not otherwise
indicated.

5.

Multiple RANDOM subcase information entries with non-unique IDs are allowed in a single
model. Therefore, if the plot-type field is set to PSDF, then the RANDOM ID will be added
to the XYPUNCH headers in the corresponding result sections of the .pch file when
multiple RANDOM entries are present in the same deck. If only one RANDOM entry is
present, the RANDOM ID is not printed.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

231

YTITLE
I/O Options Entry
YTITLE Output Request
Description
The YTITLE command can be used in the I/O Options section to define the y-axis label for
XYPUNCH or XYPLOT output from a random response analysis.
Format
YTITLE = title

Argument

Description

title

Character string.
Default = blank

Comments
1.

YTITLE may not be continued onto the next line.

2.

A YTITLE definition applies to all plots defined after YTITLE until another definition of
YTITLE occurs.
Example:
XTITLE
YTITLE
XYPLOT
YTITLE
TCURVE
XYPLOT

= X-A
= Y-A
(first plot definition)
= Y-B
= C-A
(second plot definition)

would assign X-A, Y-A and the default plot title to the first plot, then X-A, Y-B, and C-A
to the second plot.

232

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Subcase Information Section

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

233

A2GG
Subcase Information Entry
A2GG - Direct Input Fluid-Structure Coupling Matrix Selection
Description
The A2GG command can be used in the Subcase Information section to select a direct input
fluid-structure coupling matrix.
Format
A2GG = name

Argument

Description

name

Name of a fluid-structure coupling matrix that is input in the bulk data


section using the DMIG card.

Comments
1.

DMIG matrices will not be used unless selected in the Subcase Information section.

2.

The matrix selected applies to all subcases.

3.

The selected fluid-structure coupling matrix is always added to the computed coupling
matrix.

4.

The referenced DMIG entry must be a square matrix (field 4 must be 1), where GJ
corresponds to fluid points, CJ = 0, Gi corresponds to structural points, Ci corresponds to
DOF, and Ai corresponds to the area values.

5.

Multiple instances of A2GG are not allowed, and will result in an error termination.

234

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ANALYSIS
Subcase Information Entry
ANALYSIS - Run Control and Solution Sequence Identifier
Description
The ANALYSIS command can be used in the I/O Options section to request that only a finite
element analysis be performed (optimization input is ignored). It may also be used in the I/O
Options or Subcase Information sections to identify the solution sequence for all subcases or
for individual subcases, respectively.
Format
ANALYSIS = option

Argument

Options

Description

option

<ONLY, OPTSKIP,
STATICS, NLSTAT,
MODES, MCEIG,
BUCK, DFREQ,
MFREQ, DTRAN,
MTRAN, DFOUR,
MFOUR, HEAT,
NLHEAT, MBD,
NLGEOM, IMPDYN,
EXPDYN, FATIGUE>

The first two options ONLY and OPTSKIP refer to the run
control functionality of the ANALYSIS command:

Default = ONLY

The remaining options refer to the solution sequence


identification functionality of the ANALYSIS command:

Altair Engineering

ONLY:

Performs finite element analysis run only.


Optimization inputs are checked but
ignored.

OPTSKIP:

Performs finite element analysis run only.


Optimization inputs are ignored.

STATICS:

Linear static or nonlinear quasi-static gap


analysis.

NLSTAT:

Nonlinear quasi-static analysis.

HEAT:

Linear steady-state heat transfer analysis


or linear transient heat transfer analysis.

NLHEAT:

Nonlinear steady-state heat transfer


analysis.

MODES:

Normal modes analysis.

MCEIG:

Modal complex eigenvalue analysis.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

235

Argument

Options

Description
BUCK:

Linear buckling analysis.

DFREQ:

Direct frequency response analysis.

MFREQ:

Modal frequency response analysis.

DTRAN:

Direct transient response analysis.

MTRAN:

Modal transient response analysis.

DFOUR:

Direct transient response analysis through


Fourier transformation.

MFOUR:

Model transient response analysis through


Fourier transformation.

MBD:

Multi-body dynamics analysis.

NLGEOM:

Geometric nonlinear implicit (quasi-)static


analysis.

IMPDYN:

Geometric nonlinear implicit dynamic


analysis.

EXPDYN:

Geometric nonlinear explicit dynamic


analysis.

FATIGUE:

Fatigue analysis.

Comments
1.

ANALYSIS=ONLY or ANALYSIS=OPTSKIP are only applicable in the I/O Options section.

2.

ANALYSIS=ONLY or ANALYSIS=OPTSKIP may be used in combination with one of the other


ANALYSIS options.

3.

When ANALYSIS=ONLY or ANALYSIS=OPTSKIP are used, all elements (including design


elements) are treated as non-design elements.

4.

When ANALYSIS=ONLY or ANALYSIS=OPTSKIP are used, all properties and grids referenced
by size and shape variables will be set at the values on the associated property and GRID
data.

236

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

B2GG
Subcase Information Entry
B2GG Direct Input Viscous Damping Matrix Selection
Description
The B2GG command can be used in the Subcase Information section to select a direct input
viscous damping matrix.
Format
B2GG = name

Argument

Description

name

Name of a damping matrix that is input in the bulk data section using the
DMIG card.

Comments
1.

DMIG matrices will not be used unless selected.

2.

This matrix is handled like the damper elements CDAMPi and CVISC.

3.

Terms are added to the viscous damping matrix before any constraints are applied.

4.

The matrix must be symmetric, that is field 4 on the referenced DMIG entry must contain
the integer 6.

5.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

237

CMETHOD
Subcase Information Entry
CMETHOD Data Selection
Description
The CMETHOD command can be used in the Subcase Information section to select the method
for complex eigenvalue extraction.
Format
CMETHOD = option

Argument

Options

Description

option

< SID >

SID:

Set identification of an EIGC bulk data entry.

No default
Comments
1.

Only one CMETHOD entry can be defined in a subcase.

2.

A CMETHOD entry is required for complex eigenvalue analysis.

3.

If present above the first subcase, it is applied to all complex eigenvalue subcases.

238

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMSMETH
Subcase Information Entry
CMSMETH Run Control
Description
The CMSMETH command can be used in the Subcase Information section to request that only a
component mode synthesis solution be performed and to select a component mode synthesis
method definition to be used.
Format
CMSMETH = option

Argument

Option

Description

option

<CMSID>

CMSID: Identification of a CMSMETH bulk data entry.

No default
Comments
1.

All subcases must have the same MPC reference; in which case it runs the component
mode synthesis (flexible-body preparation) solution sequence using the CMSMETH reference
and the common MPC reference.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

239

CNTNLSUB
Subcase Information Entry
CNTNLSUB Continue nonlinear solution sequence from a preceding nonlinear subcase
Description
The CNTNLSUB command can be used in the Subcase Information section to continue a
nonlinear solution from a preceding nonlinear subcase, and thus create complex loading
sequences.
Format
CNTNLSUB = option

Argumen Option
t

Description

option

Yes:

<Yes, No,
SID>
Default = Yes

240

This nonlinear subcase continues the nonlinear


solution from the nonlinear subcase immediately
preceding.
"Preceding" refers to the sequence of subcases
in the deck, not the subcase numbering. If
CNTNLSUB,YES is used within a subcase, then
the preceding subcase must be nonlinear
subcase of the same type. If CNTNLSUB,YES is
used above the first subcase, then all the
consecutive nonlinear subcases of the same
type will continue each other (however, other
types of subcases interspersed between
nonlinear ones will break the continuation
sequence).

No:

This nonlinear subcase executes a new solution


sequence starting from the initial, stress-free
state of the model. See comment 1.

SID: Subcase
ID

This nonlinear subcase continues nonlinear


solution from SUBCASE SID. SUBCASE SID must
precede the current subcase in the deck and
must be a nonlinear subcase of the same type.
See comment 1.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

This command applies only to nonlinear subcases.


Nonlinear subcases may only be continued from other nonlinear subcases of the same
analysis type. that is, geometric linear subcases (ANALYSIS=NLSTAT) may only be
continued from other geometric linear subcases, and geometric nonlinear subcases
(ANALYSIS=NLGEOM, IMPDYN or EXPDYN) may only be continued from other geometric
nonlinear subcases.

2.

Only one CNTNLSUB entry can be defined for each subcase.

3.

If CNTNLSUB = option is present above the first subcase, it is applied to all nonlinear
subcases. (CNTNLSUB = SID is only allowed within a subcase).

4.

CNTNLSUB is mostly relevant in path-dependent problems, such as plasticity or gap/


contact analysis with friction/stick. In these problems, subcase continuation can be used
to create complex loading paths that will typically produce very different results than
simple proportional loading of a single subcase. CNTNLSUB also affects the convergence
history and, to some extent, the results in problems that typically are not pathdependent, such as gap/contact analysis without friction.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

241

DEFORM
Subcase Information Entry
DEFORM Data Selection
Description
The DEFORM command can be used in the Subcase Information section to select an element
deformation set.
Format
DEFORM = option

Argument

Options

Description

option

< SID >

SID:

Set identification of a DEFORM bulk data entry.

Comments
1.

Only one DEFORM entry can be defined for each subcase.

2.

If present above the first subcase, it is applied to all linear static, linear buckling, and
nonlinear quasi-static (Gap/Contact) subcases.

242

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DESOBJ
Subcase Information Entry
DESOBJ Objective Selection
Description
The DESOBJ command is used in the Subcase Information section to select a single response
definition as the objective function of an optimization, or to select system response definitions
when the objective function is the least squares sum of these definitions. The DESOBJ
command also indicates if this response is to be minimized or maximized.
Format
DESOBJ (type) = integer, PROB

Argument

Options

Description

type

<MIN, MAX,
MINP, MAXP>

MIN:

The objective is to minimize the


response.

Default = MIN

MAX:

The objective is to maximize the


response.

MINP:

The objective is to minimize the percentile


value of the response (see comment 8).

MAXP:

The objective is to maximize the


percentile value of the response (see
comment 8).

ID:

Identification number of a DRESP1,


DRESP2, DRESP3, or DSYSID bulk data
entry.

integer

< ID >
No default

PROB

<Probability> Probability
<50.0 < Real <
100.00>

Altair Engineering

Probability related to the reliability


requirement (see comment 8).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

243

Comments
1.

Only one DESOBJ card can be present.

2.

For global DRESP1 responses (responses which are not subcase dependent) or DRESP2 or
DRESP3 responses containing either DRESP1L/DRESP2L data or global DRESP1 responses,
the DESOBJ data must be above the first SUBCASE statement.

3.

If the DESOBJ data references responses that are subcase specific, then the DESOBJ
statement must be within the appropriate subcase definition and the subcase must be of
the appropriate type.

4.

If the DSYSID entry is referenced by a DESOBJ subcase entry, a least squares objective
function is used in the optimization. The objective function is the sum of the squared,
weighted, normalized differences between the target responses and those calculated by
the finite element analysis.

5.

DSYSID entries must have unique identification numbers with respect to DRESP1, DRESP2,
and DRESP3 entries.

6.

DRESP1, DRESP2, and DRESP3 entries referenced by the DSYSID entry can define only a
single response per subcase when the DESOBJ formulation is used.

7.

Time dependent responses should not be referenced by the DESOBJ entry. The minmax
formulation should be used for optimization problems that have time-dependent responses
as the objective functions. The minmax formulation can be selected using the MINMAX or
MAXMIN subcase information entry.

8.

The MAXP, MINP, and PROB options can be input during a Reliability-based Design
Optimization run. MINP and MAXP are not supported if random design variables or random
parameters are not defined in the model.

9.

This entry is represented as an optimization objective in HyperMesh.

244

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DESSUB
Subcase Information Entry
DESSUB Constraint Selection
Description
The DESSUB command can be used in the Subcase Information section, within a subcase
definition, to select a constraint set that is subcase dependent.
Format
DESSUB = integer

Argument

Options

Description

integer

< SID >

SID:

Set identification of a DCONSTR or DCONADD


bulk data entry.

No default
Comments
1.

The constrained response referenced by the DESSUB constraint selection must be subcase
dependent.

2.

This entry is represented as an optimizationconstraint in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

245

DESVAR
Subcase Information Entry
DESVAR Data Selection
Description
The DESVAR command can be used in the Subcase Information section to select a set of
design variables for use in an optimization run.
Format
DESVAR = option

Argument

Options

Description

option

<ALL, SID >

ALL:

All design variables in the input data, as defined


by DESVAR bulk data entries, are used in the
optimization.

SID:

The ID of a SET I/O Option definition. Only


those design variables, as defined by DESVAR
bulk data entries with IDs appearing in the
referenced SET entry are considered in the
optimization.

Default = ALL

Comments
1.

Only one DESVAR command may appear in the Subcase Information section and should
appear before the first SUBCASE statement.

2.

The DESVAR command is optional. If it is absent, all DESVAR bulk data entries will be
used.

3.

DESVAR bulk data entries that are not selected by this command are frozen at their initial
values (that is same as setting XINIT=XLB=XUB) and all referenced properties will still be
governed by the DESVAR settings.

246

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DLOAD
Subcase Information Entry
DLOAD - Data Selection
Description
The DLOAD command can be used in the Subcase Information section to select a dynamic load
to be applied in a transient or frequency response problem.
Format
DLOAD = option

Argument

Options

Description

option

< SID >

SID:

No default

Set identification of a DLOAD, TLOAD1, TLOAD2,


RLOAD1, RLOAD2, ACSRCE, or CAALOAD bulk data
entry.

Comments
1.

RLOAD1 and RLOAD2 are for frequency response loadings.

2.

TLOAD1 and TLOAD2 are for transient response loadings.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

247

EIGVRETRIEVE
Subcase Information Entry
EIGVRETRIEVE - External Data Selection
Description
The EIGVRETRIEVE command can be used in the Subcase Information section to retrieve
eigenvalue and eigenvector results of a normal modes analysis from an external data file
(.eigv).
Format
EIGVRETRIEVE = integer1, integer2, integer3, ...

Argument

Options

Description

integer#

<integer>

Retrieves eigenvalues and eigenvectors from


external data files for use in a modal frequency
response analysis.

No default

The external eigenvalue data file names are of the


form:
<prefix>_#.eigv
where <prefix> is defined by the EIGVNAME I/O
Options entry and # is one of the integer
arguments defined here.
Comments
1.

Only one occurrence of EIGVRETRIEVE is permitted per subcase.

2.

When multiple integer arguments are provided, eigenvalues are retrieved from multiple
external data files and combined.

3.

If EIGVRETRIEVE is not present, eigenvalue and eigenvector results are not retrieved from
external data files and a normal modes analysis is performed for the modal frequency
response or modal transient response analysis subcase.

248

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EIGVSAVE
Subcase Information Entry
EIGVSAVE - Output Request
Description
The EIGVSAVE command can be used in the Subcase Information section to output eigenvalue
and eigenvector results of a normal modes analysis to an external data file (.eigv).
Format
EIGVSAVE = integer

Argument

Options

Description

integer

<integer>

Outputs eigenvalues and eigenvectors obtained


from a normal modes analysis to an external data
file.

No default

The external eigenvalue data file name is of the


form:
<prefix>_#.eigv
where, <prefix> is defined by the EIGVNAME I/O
Options entry and # is the integer argument
defined here.
Comments
1.

Only one occurrence of EIGVSAVE per subcase is permitted.

2.

If EIGVSAVE is not present, eigenvalue and eigenvector results do not get exported to an
external data file.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

249

ESLTIME
Subcase Information Entry
ESLTIME Data Selection
Description
The ESLTIME command can be used in the Subcase Information section to select particular
time steps for geometric nonlinear response ESLM optimization or Multi-body Dynamics ESLM
optimization.
Format
ESLTIME = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification number of an ESLTADD or


ESLTIME bulk data entries (see Comments 1 and
2).

Comments
1.

Only one ESLTIME entry can be present for each subcase. It can only be used in
subcases that contain an ANALYSIS = NLGEOM, IMPDYN, EXPDYN or MBD entry.

2.

If the SID referenced by the ESLTIME subcase information entry matches with the SID
defined for an ESLTADD bulk data entry, then the information on this entry alone is
selected. However, if an ESLTADD bulk data entry does not exists with the referenced
SID, then any ESLTIME bulk data entries that have this SID will be selected.

250

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EXCLUDE
Subcase Information Entry
EXCLUDE - Exclusion Set Selection
Description
The EXCLUDE command can be used in the Subcase Information section to select a set of
elements to be excluded from a linear buckling analysis.
Format
EXCLUDE = option

Argument

Options

Description

option

<ESID>

ESID - set identification number of an element set.

No default
Comments
1.

The element set is defined using the SET bulk data entry.

2.

This subcase information entry is only valid when it appears in a buckling subcase.

3.

The excluded elements are only removed from the geometric stiffness matrix, resulting in
a buckling analysis with elastic boundary conditions. This means that the excluded
elements may still be showing movement in the buckling mode.

4.

Extreme caution is advised when using the EXCLUDE command. In general, excluding any
region from buckling analysis can, and usually will, result in a higher, overestimated critical
load calculation, which then may produce false overconfidence in a structures load
bearing capacity. The excluded region will have no effect on the calculated critical load
only if the excluded modes are geometrically separated from, or orthogonal to, the actual
critical buckling mode.

5.

A descriptive engineering explanation is as follows: buckling analysis by design seeks the


weakest, least stable configuration of the structure. Excluding any region from this
search can cause you to miss the actual critical buckling mode that involves the
respective region and has the least load bearing capacity.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

251

FATDEF
Subcase Information Entry
FATDEF Data Selection
Description
The FATDEF command can be used in the Subcase Information section to select a FATDEF bulk
data entry that will define the elements, and their associated fatigue properties, to be
considered for fatigue analysis.
Format
FATDEF = option

Argument

Option

Description

Option

< SID >

SID:

Set identification of a FATDEF bulk data entry.

No default
Comments
1.

FATDEF bulk data entries will not be used unless selected in the Subcase Information
section.

2.

If present above the first subcase, it is applied to all fatigue analysis subcases.

252

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FATPARM
Subcase Information Entry
FATPARM Data Selection
Description
The FATPARM command can be used in the Subcase Information section to select a FATPARM
bulk data entry that will define the parameters to be used for a fatigue analysis.
Format
FATPARM = option

Argument

Option

Description

Option

< SID >

SID:

Set identification of a FATPARM bulk data entry.

No default
Comments
1.

FATPARM bulk data entries will not be used unless selected in the Subcase Information
section.

2.

If present above the first subcase, it is applied to all fatigue analysis subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

253

FATSEQ
Subcase Information Entry
FATSEQ Data Selection
Description
The FATSEQ command can be used in the Subcase Information section to indicate that a
subcase is a fatigue analysis subcase and to select a FATSEQ bulk data entry that will define
the loading sequence for the fatigue analysis.
Format
FATSEQ = option

Argument

Option

Description

Option

< SID >

SID:

Set identification of a FATSEQ bulk data entry.

No default
Comments
1.

254

This command may not appear above the first subcase.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQUENCY
Subcase Information Entry
FREQUENCY - Data Selection
Description
The FREQUENCY command can be used in the Subcase Information section to select the set of
forcing frequencies to be solved in a frequency response problem.
Format
FREQUENCY = option

Argument

Option

Description

option

< SID >

SID:

Set identification of FREQ, FREQ1, FREQ2, FREQ3,


FREQ4, and FREQ5 bulk data entries.

No default
Comments
1.

A frequency set selection is required for transient response by the Fourier transform
method when TSTEP (FOURIER) is used. The Fourier transform will be performed at the
frequencies specified.

2.

All FREQi data with the same set identification number will be used.

3.

If present above the first subcase, it is applied to each frequency response or transient
subcase without a FREQUENCY command.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

255

GLOBSUB
Subcase Information Entry
GLOBSUB - Global Model and Transfer Zone Selection
Description
The GLOBSUB entry can be used in the Subcase Information section to select a subcase that
references the global structure for local-global analysis. A set of grid points in the local
structure that defines the transfer zone can also be specified.
Format
GLOBSUB, SUBID, SID

Argument

Value

Description

SUBID

<integer > 0> Specifies the identification number of the subcase that
contains the global structure definition (via SUBMODEL).

SID

<integer > 0> Specifies the set of grid points in the local structure
that defines the transfer zone. The displacements from
the global structure are interpolated and applied to this
set of grid points.

Comments
1.

The transfer zone should contain only 3-dimensional elements in both the local and global
structures. Second order elements (for example, CHEXA20) are allowed. There is no
further restriction on element types elsewhere in the structure.

2.

The transfer zone may represent single or multiple cuts (sections) through the structure.
Multiple cuts should be separated from each other, that is, they should not exist closer
than the element size of the global model.

3.

The GLOBSUB entry should always reference the subcase ID of a global subcase that is
defined above its corresponding local subcase.

256

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GROUNDCHECK
Subcase Information Entry
GROUNDCHECK Rigid Body Motion Grounding Check
Description
The GROUNDCHECK command can be used in the Subcase Information section to perform a
grounding check analysis on the stiffness matrix to expose unintentional constraints by moving
the model rigidly.
Format
GROUNDCHECK(print,GRID=gid,THRESH=thresh) = option

Argument

Option

Description

print

< PRINT, NOPRINT >


Default = PRINT

PRINT:

Write output to the .out file.

NOPRINT:

Do not write output to the .out file.

grid

< GID >


Default = geometric
center of the
structure.

Grid Point ID: Reference grid point for the


calculation of the rigid body motion.

thresh

<e>
Default = largest term
in the stiffness matrix,
divided by 1.0E10.

Maximum strain energy which passes the check.

option

< YES, NO >


Default = YES

YES: Grounding check is performed.


NO:

Grounding check is not performed.

Comments
1.

GROUNDCHECK must be specified before the first SUBCASE.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

257

2.

Grounding check is performed on all degrees-of-freedom of the model and all degrees-offreedom that are not constrained by SPC. MPC equations are not used in the check.

3.

Any MPC that will be violated due to rigid body modes is reported. An equivalent energy
magnitude is also calculated between MPC violation and the strain energy. The
equivalent energy from MPC violation is added to the strain energy when performing the
grounding check.

258

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

IC
Subcase Information Entry
IC Transient and Explicit Analysis Initial Condition Set Selection
Description
The IC command may be used in the Subcase Information section to select initial conditions
for transient and explicit analysis.
Format
IC = option
Example
IC = 10

Argument

Option

Description

option

< SID >

SID:

Set identification number of TEMP, TEMPD, TIC,


TICA bulk data entries.

No default
Comments
1.

TIC and TICA entries will not be used (therefore, no initial conditions) unless selected in
the Subcase Information section.

2.

Initial conditions cannot be used with modal transient analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

259

INVEL
Subcase Information Entry
INVEL Multi-Body Initial Velocity Selection
Description
The INVEL command can be used in the Subcase Information section to select a multi-body
initial velocity set to be applied in a multi-body problem.
Format
INVEL = option

Argument

Option

Description

option

< SID >

SID:

Set identification if INVELB or INVELJ bulk data


entries.

No default
Comments
1.

Only one INVEL entry can be present for each subcase.

2.

This subcase information entry is only valid when it appears in a multi-body subcase.

260

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

K2GG
Subcase Information Entry
K2GG - Direct Input Stiffness Matrix Selection
Description
The K2GG command can be used in the Subcase Information section to select a direct input
stiffness matrix.
Format
K2GG = name

Argument

Description

name

Name of a stiffness matrix that is input in the bulk data section using
the DMIG card or name list, with or without factors.

Example
K2GG=KAAX
K2GG=1.25*KAAX,1.5*KBBX
Comments
1.

DMIG matrices will not be used unless selected in the Subcase Information section.

2.

The matrix selected applies to all subcases.

3.

The matrix must be symmetric, that is field 4 on the referenced DMIG entry must contain
the integer 6.

4.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

5.

The entries in the name list are separated by comma or blank. With factors, each entry
consists of a factor followed by a star and a name. The factors are real numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

261

K2PP
Subcase Information Entry
K2PP - Direct Input Stiffness Matrix Selection
Description
The K2PP command can be used in the Subcase Information section to select a direct input
stiffness matrix, which is not included in normal modes.
Format
K2PP = name

Argument

Description

name

Name of a stiffness matrix that is input in the bulk data section using
the DMIG card.

Comments
1.

DMIG matrices will not be used unless selected in the Subcase Information section.

2.

The matrix selected applies to all subcases.

3.

K2PP matrices are used only in dynamic response problems. They are not used in normal
modes.

4.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

262

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

K42GG
Subcase Information Entry
K42GG - Direct Input Structural Element Damping Matrix Selection
Description
The K42GG command can be used in the Subcase Information section to select a direct input
structural element damping matrix.
Format
K42GG = name

Argument

Description

name

Name of a damping matrix that is input in the bulk data section using the
DMIG card.

Comments
1.

DMIG matrices will not be used unless selected.

2.

This matrix is handled like the contributions from the structural element damping
coefficients GE on MATi, PBUSH, and PELAS.

3.

Terms are added to the damping matrix before any constraints are applied.

4.

The matrix must be symmetric, that is field 4 on the referenced DMIG entry must contain
the integer 6.

5.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

263

LABEL
Subcase Information Entry
LABEL - Subcase Label
Description
The LABEL command can be used in the Subcase Information section to provide a subcase
with a label.
Format
LABEL = name

Argument

Description

name

Any string of ASCII characters can be used to label a subcase.

Comments
1.

264

This label is inserted into output files for post-processing purposes.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

LOAD
Subcase Information Entry
LOAD Data Selection
Description
The LOAD command can be used in the Subcase Information section to select a static load set
to be applied in linear static solutions.
Format
LOAD = option

Argument

Options

Description

option

< SID >

SID:

No default

Set identification of a LOAD bulk data entry or,


if no LOAD bulk data entry exists with this SID,
the set identification of FORCE, FORCE1,
MOMENT, MOMENT1, PLOAD, PLOAD1, PLOAD2,
PLOAD4, GRAV, RFORCE, and SPCD, bulk data
entries.

Comments
1.

Only one LOAD entry can be present for each subcase.

2.

A METHOD entry cannot be present in the same subcase definition as a LOAD entry.

3.

If the SID referenced by the LOAD subcase information entry matches with the SID
defined for a LOAD bulk data entry, the information on this entry alone is selected.
However, if no LOAD bulk data entry has the referenced SID defined, any of the static
load entries: FORCE, FORCE1, MOMENT, MOMENT1, PLOAD, PLOAD1, PLOAD2, PLOAD4,
GRAV, RFORCE, and SPCD, which have this SID will be selected.

4.

In versions of OptiStruct prior to 8.0, thermal loads were selected in the Subcase
Information section using the LOAD data selector. In version 8.0, the TEMPERATURE data
selector was added to perform this function. It is possible to revert to the old behavior
mode by setting the LOADTEMP option to SHAREID in the OptiStruct Configuration File.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

265

M2GG
Subcase Information Entry
M2GG - Direct Input Mass Matrix Selection
Description
The M2GG command can be used in the Subcase Information section to select a direct input
mass matrix.
Format
M2GG = name

Argument

Description

name

Name of a mass matrix that is input in the bulk data section using the
DMIG card.

Comments
1.

DMIG matrices will not be used unless selected in the Subcase Information section.

2.

The matrix selected applies to all subcases.

3.

The matrix must be symmetric, that is field 4 on the referenced DMIG entry must contain
the integer 6.

4.

By default, mass contribution of the external mass matrix (M2GG) is considered for the
generation of gravity and centrifugal loads.

5.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

266

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBSIM
Subcase Information Entry
MBSIM Multi-Body Simulation Selection
Description
The MBSIM command can be used in the Subcase Information section to select a multi-body
simulation definition to be applied in a multi-body problem.
Format
MBSIM = option

Argument

Option

Description

option

< SID >

SID:

Set identification of MBSEQ, MBSIM, or MBLIN bulk


data entries.

No default
Comments
1.

Only one MBSIM entry can be present for each subcase.

2.

This subcase information entry is only valid when it appears in a multi-body subcase.

3.

MBSIM can be used to select only one bulk data entry. MBSEQ, MBSIM, and MBLIN must
have unique IDs.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

267

METHOD
Subcase Information Entry
METHOD - Data Selection
Description
The METHOD command can be used in the Subcase Information section to select a method for
real eigenvalue extraction.
Format
METHOD (type) = option

Argument

Options

Description

type

<STRUCTURE,
FLUID>

The referenced EIGRL or EIGRA bulk data entry is applied


to the structural (STRUCTURE) or fluid (FLUID) portion of
the model.

Default =
Structure
option

< SID >


No default

SID: Set identification of an EIGRL or EIGRA bulk data


entry.

Comments
1.

Only one METHOD entry of each type can be defined for each subcase.
If only one type of METHOD entry is defined (either METHOD(STRUCTURE) or
METHOD(FLUID)), this definition will be used for both the structure and the fluid portion of
the model.

2.

A METHOD entry cannot be present in the same subcase definition as a LOAD entry.

3.

A METHOD entry is required for normal modes, linear buckling, modal frequency response,
and modal transient response solution sequences.

4.

If present above the first subcase, it is used in all subsequent subcases which can accept
a METHOD entry. However, this does not apply to subcases which already contain their
own METHOD entry.

5.

AMSES can be used for the fluid (FLUID) part of the model. METHOD(FLUID) can reference
an EIGRA bulk data entry.

268

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MFLUID
Subcase Information Entry
MFLUID - Virtual Fluid Mass Selection
Description
The MFLUID command can be used in the Subcase Information section to select the
parameters and damp elements and activate the calculation of virtual fluid mass.
Format
MFLUID = option

Argument

Options

Description

option

< SID >

SID:

Set identification number of one or more MFLUID


bulk data entries.

No default
Comments
1.

Only one MFLUID entry can be present.

2.

MFLUID may be requested for a normal modes, complex eigenvalue, frequency response,
or transient response analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

269

MINMAX or MAXMIN
Subcase Information Entry
MINMAX / MAXMIN - Objective Selection
Description
The MINMAX or MAXMIN commands can be used in the Subcase Information section to select
normalized response or system identification definitions as the objective function for a
"Minmax" or "Maxmin" optimization.
Format
MINMAX = integer
MAXMIN = integer

Argument

Options

Description

integer

< DOID >

DOID:

Design objective identification number of a


DOBJREF or DSYSID bulk data entry.

No default
Comments
1.

Multiple MINMAX entries are allowed and multiple MAXMIN entries are allowed, but a MAXMIN
entry cannot appear in the same input file as a MINMAX entry.

2.

The multiple MINMAX or MAXMIN entries define the same optimization problem.

3.

Refer to the Optimization Problem page of the User's Guide for more information on
"Minmax" optimization.

4.

If the DSYSID entry is referenced by a MINMAX or a MAXMIN subcase entry, the beta
method is applied in the optimization as follows:

5.

This entry is represented as an optimization objective in HyperMesh.

270

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MLOAD
Subcase Information Entry
MLOAD Multi-Body Load Selection
Description
The MLOAD command can be used in the Subcase Information section to select a multi-body
load set to be applied in a multi-body problem.
Format
MLOAD = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification of GRAV, MBFRC, MBFRCC,


MBFRCE, MBMNT, MBMNTC, MBMNTE, MBSFRC,
MBSFRCC, MBSFRCE, MBSMNT, MBSMNTC,
MBSMNTE, and MLOAD bulk data entries.

Comments
1.

Only one MLOAD entry can be present for each subcase.

2.

This subcase information entry is only valid when it appears in a multi-body subcase.

3.

If the SID referenced by the MLOAD subcase information entry matches with the SID
defined for an MLOAD bulk data entry, the information on this entry alone is selected.
However, if no MLOAD bulk data entry has the referenced SID defined, any of the multibody load entries: GRAV, MBFRC, MBFCC, MBFRCE, MBMNT, MBMNTC, MBMNTE, MBSFRC,
MBSFRCC, MBSFRCE, MBSMNT, MBSMNTC, or MBSMNTE which have this SID will be
selected.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

271

MODESELECT
I/O Options and Subcase Information Entry
MODESELECT Mode Selection
Description
The MODESELECT command can be used in the I/O Options or the Subcase Information section
to select a subset of computed modes in modal dynamic analysis subcases.
Format
MODESELECT (type) = n
Mode selection based on arbitrary mode numbers.
Alternate Format 1
MODESELECT (type, LMODES = lm)
Mode selection based on lowest modes.
Alternate Format 2
MODESELECT (type, LMODENM = lom, HMODENM = him)
Mode selection based on a range of mode numbers.
Alternate Format 3
MODESELECT (type, LFREQ = lof, HFREQ = hif, UNCONSET = m)
Mode selection based on a range of frequencies.

Argument

Options

Description

type

STRUCTURE

If STRUCTURE is specified, the MODESELECT command


references modes associated with structural analysis only.

(Default)

FLUID

If FLUID is specified, the MODESELECT command references


modes associated with fluid analysis only.

n > 0

Set identification number n of a set of mode numbers. The


modes corresponding to the mode numbers specified in set n
will be included in the analysis. If no such set exists, then
mode n will be included in the analysis.

(Integer)

n < 0
(Integer)

272

Set identification number |n| of a set of mode numbers. The


modes corresponding to the mode numbers specified in set |
n| will be excluded from the analysis. If no such set exists,

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description
then mode |n| will be excluded from the analysis.

LMODES

Specifies the number of lowest modes to be selected.

lm
(Integer > 0)

LMODENM

lom
(Integer > 0)

HMODENM

him
(Integer > lom
> 0)

LFREQ

Specifies the upper bound of the mode number range for


selecting modes (See comment 3).

Specifies the lower bound of the frequency range for


selecting modes (See comment 4).

lof
(Real > 0.0)

HFREQ

Specifies the lower bound of the mode number range for


selecting modes (See comment 3).

hif
(Real > lof >
0.0)

Specifies the upper bound of the frequency range for


selecting modes (See comment 4).

UNCONSET

UNCONSET

This flag indicates that the following fields specify a single


mode or a set of modes for unconditional inclusion or
exclusion.

m > 0

Set identification number m of a set of mode numbers. The


modes corresponding to the mode numbers specified in set m
will be unconditionally included in the analysis. If no such set
exists, then mode m will be unconditionally included in the
analysis.

(Integer)

m < 0
(Integer)

Set identification number |m| of a set of mode numbers. The


modes corresponding to the mode numbers specified in set |
m| will be unconditionally excluded from the analysis. If no
such set exists, then mode |m| will be unconditionally
excluded from the analysis.

Comments
1.

The MODESELECT I/O Options entry is only supported in modal frequency response, modal
transient and complex eignenvalue analyses. It is not supported in Response Spectrum
Analysis.

2.

Multiple MODESELECT entries are allowed in a model. MODESELECT entries can be specified
above the first subcase or within each subcase.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

273

3.

If LMODENM is specified without HMODENM, a default value of 10000000 (ten million) is


assumed for HMODENM. If HMODENM is specified without LMODENM, a default value of 1 is
assumed for LMODENM.

Defaults

4.

LMODENM

HMODENM

specified

1.0E+7

specified

If LFREQ is specified without HFREQ, a default value of 1.0E+30 is assumed for HFREQ. If
HFREQ is specified without LFREQ, a default value of 0.0 is assumed for LFREQ.

Defaults

LFREQ

HFREQ

specified

1.0E+30

0.0

specified

5.

When the MODESELECT Case Control command is used in conjunction with the parameter
LFREQ, the MODESELECT Case Control takes precedence.

6.

If the use of MODESELECT results in all or none of the computed modes for use, you are
informed with a message.

7.

The faster method for modal frequency response analysis (activated by


PARAM,FASTFR,YES) cannot be used in conjunction with MODESELECT.

8.

Modes that are eliminated by MODESELECT will display:

274

a)

an S next to the mode number, if the mode is eliminated by MODESELECT in one


subcase and PARAM, LFREQ or PARAM, HFREQ in another subcase, or

b)

an M next to the mode number, if eliminated by MODESELECT in at least one


subcase.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MODEWEIGHT
Subcase Information Entry
MODEWEIGHT - Optimization Parameter
Description
The MODEWEIGHT command can be used in the Subcase Information section to define a
multiplier for computed eigenvalues that are to be used in the calculation of the "weighted
reciprocal eigenvalue" and "combined compliance index" optimization responses.
Format
MODEWEIGHT (mode) = weight

Argument

Description

mode

Mode number.
No default (0 < Integer < highest calculated mode)

weight

The multiplier to be used for the corresponding mode in the calculation of


"weighted reciprocal eigenvalue" or "combined compliance index."
Default = 1.0 (Real)

Comments
1.

OptiStruct will terminate with an error if no mode number is provided.

2.

Modes for which there is no MODEWEIGHT definition are not included in the calculation of
the "weighted reciprocal eigenvalue" and "combined compliance index" optimization
responses.

3.

Refer to the Responses page of the User's Guide for more information on "weighted
reciprocal eigenvalue" and "combined compliance index" optimization response
calculations.

4.

MODEWEIGHT is only used in conjunction with DRESP1, RTYPE = WFREQ, COMB.

5.

If there is no MODEWEIGHT defined, but a DRESP1 with RTYPE = WCOMP exists, the
following default is applied:
MODEWEIGHT (1) = 1.0 in most cases for topology optimization.
MODEWEIGHT (7) = 1.0 if no SPC is defined for the subcase, EIGRL does not define a V1
> 0.0, and it is solving for more than 6 modes or all modes below an upper bound.

6.

This entry is represented as an optimization response in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

275

MODTRAK
Subcase Information Entry
MODTRAK Controls Mode Tracking
Description
The MODTRAK command can be used in the Subcase Information section to control mode
tracking.
Format
MODTRAK = option

Argument

Options

Description

option

<ON, OFF, blank>

ON or blank:

Mode tracking is active.

OFF:

Mode tracking is not active.

Default = OFF
Comments
1.

MODTRAK entry is only valid for normal modes subcases.

2.

If a MODTRAK entry is present in the input, then PARAM, MODETRAK is ignored.

3.

Positive integers are accepted as option, and are interpreted as ON.

4.

Negative integers or 0 are not accepted as option and will result in an error termination.

276

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTION
Subcase Information Entry
MOTION Multi-Body Motion Selection
Description
The MOTION command can be used in the Subcase Information section to select a multi-body
motion set to be applied in a multi-body problem.
Format
MOTION = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification of MOTION, MOTNG, MOTNGC,


MOTNGE, MOTNJ, MOTNJC, and MOTNJE bulk data
entries.

Comments
1.

Only one MOTION entry can be present for each subcase.

2.

This subcase information entry is only valid when it appears in a multi-body subcase.

3.

If the SID referenced by the MOTION subcase information entry matches with the SID
defined for a MOTION bulk data entry, the information on this entry alone is selected.
However, if no MOTION bulk data entry has the referenced SID defined, any of the multibody motion entries: MOTNG, MOTNGC, MOTNGE, MOTNJ, MOTHJC, or MOTIONJE which have
this SID will be selected.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

277

MPC
Subcase Information Entry
MPC - Data Selection
Description
The MPC command can be used in the Subcase Information section to select a multi-point
constraint set.
Format
MPC = option

Argument

Options

Description

option

< SID >

SID:

No default

Set identification of a MPCADD bulk data entry or, if


no MPCADD bulk data entry exists with this SID, the
set identification of an MPC bulk data entry.

Comments
1.

Only one MPC entry can be present for each subcase.

2.

If the SID referenced by the MPC subcase information entry matches with the SID defined
for a MPCADD bulk data entry, then the information on this entry alone is selected.
However, if no MPCADD bulk data entry has the referenced SID defined, then any MPC bulk
data entries that have this SID defined will be selected.

3.

If present above the first subcase, it is the default for each subcase without an MPC
command, with the exception of linear buckling analysis subcases. Linear buckling
analysis subcases inherit the MPC information from the referenced static subcase.

4.

MPC may be set to 0 to override the default in subcases where no MPC is required.

278

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NLOAD
Subcase Information Entry
NLOAD - Data Selection
Description
The NLOAD command can be used in the Subcase Information section to select a time
dependent load to be applied in geometric nonlinear analysis problem.
Format
NLOAD = option

Argument

Options

Description

option

< SID >

SID:

Set identification of an NLOAD or NLOAD1 bulk data


entry.

No default
Comments
1.

NLOAD can only be used in subcases that contain an ANALYSIS = NLGEOM entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

279

NLPARM
Subcase Information Entry
NLPARM - Data Selection
Description
The NLPARM command can be used in the Subcase Information section to activate nonlinear
solution methods for this subcase and to select the parameters used for nonlinear quasi-static
analysis and geometric nonlinear implicit analysis.
Format
NLPARM = option

Argument

Option

Description

option

< SID >

SID: Set identification of an NLPARM bulk data entry.

No default
Comments
1.

NLPARM bulk data entries will not be used unless selected in the Subcase Information
section.

2.

If present above the first subcase, it is applied to all linear static subcases. Nonlinear
quasi-static analysis subcases, by their definition, will already have an NLPARM reference
which is used.

3.

The NLPARM command is supported in quasi-static analysis, geometric nonlinear analysis,


and optimization subcases.

280

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NONLINEAR
Subcase Information Entry
NONLINEAR - Data Selection
Description
The NONLINEAR command can be used in the Subcase Information section to select a
nonlinear dynamic load set for direct transient analyses.
Format
NONLINEAR = option

Argument

Option

Description

option

< SID >

SID:

Set identification of NOLIN1, NOLIN2, NOLIN3,


NOLIN4 or NLRGAP bulk data entries.

No default
Comments
1.

NONLINEAR is only allowed in direct transient analysis subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

281

NORM
Subcase Information Entry
NORM - Optimization Parameter
Description
The NORM command can be used in the Subcase Information section to define a normalization
factor used in the computation of the "combined compliance index" optimization response.
Format
NORM = option

Argument

Description

option

Normalization factor.
Default = OptiStruct determines a weighting factor based on the lowest
eigenvalue and highest compliance of the initial iteration step. (Real)

Comments
1.

282

Refer to the Responses page of the User's Guide for more information on the "combined
compliance index" optimization response calculation.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NSM
Subcase Information Entry
NSM Data Selection
Description
The NSM command can be used in the Subcase Information section to select a non-structural
mass set for mass generation. The selector command must appear before the first SUBCASE
statement.
Format
NSM = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification number of a NSMADD bulk data


entry or, if no NSMADD bulk data entry exists with
this SID, the set identification of NSM, NSM1,
NSML and NSML1 bulk data entries.

Comments
1.

Only one NSM subcase information entry can be present in the model.

2.

This subcase information entry must appear before the first SUBCASE statement.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

283

P2G
Subcase Information Entry
P2G Direct Input Load Matrix Selection
Description
The P2G command is used before the first subcase to select a direct input load matrix.
Format
P2G = name
Examples
P2G = PAX
P2G = PAX + 2*PAY

Argument

Description

name

Name of a load matrix that is input in the bulk data section using the
DMIG card.

Comments
1.

Terms are added to the load matrix before any constraints are applied.

2.

The DMIG matrix must be rectangular (columnar), that is field 4 on the referenced DMIG
entry must contain the integer 9.

3.

A scale factor may be applied to this input using the CP2 parameter (See PARAM bulk data
entry).

4.

By default, gravity and centrifugal loads are not generated based on the external mass
matrix (M2GG). In this case, gravity and centrifugal loads should be included in generating
the reduced loads in the DMIG.

5.

When multiple instances of this card occur, the referenced DMIG entries are combined.
This behavior differs from that of Nastran, which only recognizes the last instance of this
card in the same situation.

6.

The P2G statement must be above the first SUBCASE.

7.

If the DMIG data referenced by the P2G statement has multiple load columns, then they
are applied in order in the linear and nonlinear static structural analysis subcases. If
there are more static subcases than columns, then only the subcases up to the number
of columns will get loads. If there are more columns than static subcases, then the
number of columns used with be the number of static subcases. For example, if the DMIG
has two columns and there are three static subcases, only the first two subcases will get

284

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

loads. If the DMIG has two columns and there is just one static subcase, then only the
first column is used.
8.

For more control, to add a single DMIG load to one of multiple static subcases, use
P2GSUB.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

285

P2GSUB
Subcase Information Entry
P2GSUB Direct Input Load Matrix Selection
Description
The P2GSUB command is used in a specific subcase to select a direct input load matrix.
Format
P2GSUB = factor*name (column index)
Examples
P2GSUB = PAX
P2GSUB = PAY(2)
P2GSUB = 2.5*PAZ(3)

Argument

Description

factor

Optional scale factor


<Real>
Default = 1.0

name

Name of a load matrix that is input in the bulk data section using the
DMIG card.

column index Optional column index value


<Integer > 0>
Default = 1
Comments
1.

Terms are added to the load matrix before any constraints are applied.

2.

The DMIG matrix must be rectangular (columnar), that is field 4 on the referenced DMIG
entry must contain the integer 9.

3.

A scale factor may be applied to this input using the CP2 parameter (see PARAM bulk data
entry).

4.

By default, gravity and centrifugal loads are not generated based on the external mass
matrix (M2GG). In this case, gravity and centrifugal loads should be included in generating
the reduced loads in the DMIG.

286

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

Only one name may be specified on each P2GSUB entry. Multiple P2GSUB entries may be
used inside a single subcase section to combine multiple DMIG entries (or to combine
multiple columns from the same DMIG).

6.

The P2GSUB statement cannot be specified above the first SUBCASE.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

287

PEAKOUT
Subcase Information Entry
PEAKOUT Data Selection
Description
The PEAKOUT command can be used in the Subcase Information section to select the criteria
for automatic identification of loading frequencies at which result peaks occur. Other result
output may then be requested at these peak loading frequencies. This data selector is for
frequency response solution sequences only.
Format
PEAKOUT = option

Argument

Option

Description

option

< SID >

SID:

Set identification of a PEAKOUT bulk data entry.

No default
Comments
1.

Only one PEAKOUT entry can be defined for each subcase.

2.

If present above the first subcase, it is applied to all subcases which can accept it but do
not contain a PEAKOUT card.

3.

Other result output may be obtained at the peak loading frequencies by using the PEAK
keyword in the option field. Currently, support is only available for PFMODE, PFPANEL,
and PFGRID.

4.

OFREQ is ignored when PEAKOUT is used.

288

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PRETENSION
Subcase Information Entry
PRETENSION Data Selection
Description
The PRETENSION command can be used in the Subcase Information section to select and
activate a pretensioning bolt load.
Format
PRETENSION = option

Argument

Option

Description

option

< PSID >

Pretensioning load set identification of a PTADD bulk


data entry or, if no PTADD bulk data entry exists with
this PSID, the set identification of PTFORCE, PTFORC1,
PTADJST and PTADJS1 bulk data entry.

Comments
1.

Only one PRETENSION entry can be defined for each subcase.

2.

Combinations of PRETENSION and STATSUB(PRETENS) can be used to create more complex


pretensioning sequences.

3.

The rules for sequencing pretensioning subcases on the same pretension section are as
follows:
a) Pretensioning force (PTFORCE) can only be activated in the new or fresh
pretensioning subcase for a given section. In other words, a subcase with PRETENSION
pointing to PTFORCE cannot also include STATSUB(PRETENS) referencing a subcase that
had already pretensioned this section.
b) Pretensioning adjustment (PTADJST) may be activated in any of the pretensioning
subcases for a given section. The effect of adjustment is cumulative relative to the
pretensioning status reached in the respective previous subcase, as referenced by
STATSUB(PRETENS).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

289

RANDOM
Subcase Information Entry
RANDOM Random Analysis Set Selection
Description
Selects the RANDPS and RANDT1 bulk data entries to be used in random analysis.
Format
RANDOM = n
Example
RANDOM = 177

Argument

Option

Description

(Integer > 0)

Set identification of RANDPS and RANDT1 bulk data


entries to be used in random analysis.

Comments
1.

This command must select RANDPS bulk data entries in order to perform random analysis.

2.

Multiple RANDOM data can exist in the Subcase Information section.

3.

This data can be placed anywhere in the Subcase Information section. It is not SUBCASE
specific.

290

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

REPGLB
Subcase Information Entry
REPGLB Selection of Response to be Reported without being Constrained.
Description
The REPGLB command can be used in the Subcase Information section, before the first
subcase statement, to select a report set that is not subcase dependent.
Format
REPGLB = integer

Argument

Options

Description

integer

< DRID >

DRID:

No default

Set identification of a DREPORT or DREPADD bulk


data entry.

Comments
1.

The response referenced by the REPGLB selection must not be subcase dependent.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

291

REPSUB
Subcase Information Entry
REPSUB Selection of Response to be Reported without being Constrained
Description
The REPSUB command can be used in the Subcase Information section, within a subcase
definition, to select a report set that is subcase dependent.
Format
REPSUB = integer

Argument

Options

Description

integer

< DRID >

DRID:

No default

Set identification of a DREPORT or DREPADD bulk


data entry.

Comments
1.

292

The response referenced by the REPSUB selection must be subcase dependent.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RESVEC
Subcase Information Entry
RESVEC Controls Residual Vector Calculation
Description
The RESVEC command can be used in the Subcase Information section to control the
calculation of residual vectors.
Format
RESVEC(type, damping) = option

Argument

Options

Description

type

<UNITLOD,
APPLOD>

UNITLOD:

Generates residual vectors based on unit


loads at the dynamic loading's degrees of
freedom. A unit load residual vector is
created for every loaded DOF from all
SUBCASEs. For normal modes and modal
complex eigenvalue analysis, a residual
vector is created for each USET and USET1
U6 DOF.

APPLOD:

Generates residual vectors based on the


dynamic loading of the modal frequency
response analysis at zero Hz.and transient
analysis at time = zero. For frequency
response analysis, one or two residual
vectors are generated for each SUBCASE
based on whether the real and imaginary
loads are different at zero Hz. A single
residual vector is created for each
transient SUBCASE. The values at each
loaded DOF correspond to the load on that
DOF at zero Hz. or time = zero. APPLOD is
not valid for normal modes analysis and
UNITLOD will always be used.

DAMPLOD:

Generates a viscous damping residual


vector for each viscous element based on
the eigenvector of the viscous element.

Default =
UNITLOD

damping

<DAMPLOD,
NODAMP>
Default =
DAMPLOD

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

293

Argument

option

Options

Description
NODAMP:

Turns off the generation of the viscous


damping residual vectors.

<YES, NO>

YES:

Residual vectors are calculated.

See comments
for default.

NO:

Residual vectors are not calculated.

Comments
1.

RESVEC can be requested for normal modes, modal complex eigenvalue analysis, modal
frequency response, and modal transient response analysis subcases.

2.

If the RESVEC does not exist in a subcase (and is not defined above the first subcase),
then the default is YES for modal frequency response and transient response analysis
subcases, and the default is NO for all other applicable subcases. If a RESVEC card exists
without the YES/NO option, the default is YES.

3.

If EXCITEID=SPCD is defined on RLOAD1/RLOAD2 or TLOAD1/TLOAD2, unit residual vectors


for each enforced motion DOF are always computed, even if RESVEC=NO.

4.

For normal modes analysis, the unit load method (type=UNITLOD) is applied to the
degrees-of-freedom defined by USET and USET1 U6 entities. If the Lanczos eigensolver is
used then RESVEC=YES must be present. If the AMSES or AMLS eigensolver is used, then
the USET and USET1 U6 residual vectors will always be calculated (even if RESVEC=NO is
specified).

5.

Even though DAMPLOD and NODAMP may be defined inside each subcase, the setting from
the last RESVEC data will be used for all of the modal complex eigenvalue analysis, modal
frequency response, and modal transient subcases in the model.

6.

Residual vectors from USET and USET1 U6 data are only available for modal complex
eigenvalue analysis when AMSES or AMLS is used to calculate the normal modes. They
are not created if Lanczos is used.

7.

For modal frequency response and modal transient analysis, the USET and USET1 U6
residual vectors will always be calculated if the AMSES or AMLS eigensolver is used, and
they will never be calculated if the Lanczos eigensolver is used. The RESVEC command
has no effect on the USET and USET1 U6 residual vector creation for modal frequency
response and modal transient analysis.

294

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RGYRO
Subcase Information Entry
RGYRO This data entry can be used in the subcase information section to activate
gyroscopic effects in Rotor dynamics
Description
Identifies a RGYRO bulk data entry that contains information required to implement Rotor
dynamics in Modal Complex Eigenvalue Analysis and/or Modal Frequency Response Analysis.
Format
RGYRO = option
Example
RGYRO = 3
RGYRO = NO

Argument

Option

Description

option

<SID,NO>

SID:

Identification number of a RGYRO bulk data entry.


(Integer)

NO:

Gyroscopic effects are not included in any solution


sequences.

Comments
1. Multiple RGYRO subcase information entries are allowed in different subcases, however,
only one RGYRO subcase entry can exist within each subcase.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

295

RSPEC
Subcase Information Entry
RSPEC Data Selection
Description
The RSPEC command can be used in the Subcase Information section to reference combination
rules, excitation degrees of freedom, and input spectra for use in response spectrum analysis.
Format
RSPEC = option

Argument

Options

Description

option

< SID >

SID:

Set identification of an RSPEC bulk data entry.

No default
Comments
1.

Only valid in a response spectrum analysis subcase.

2.

Refer to the Response Spectrum Analysis section of the Users Guide for more details.

296

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RWALL
Subcase Information Entry
RWALL Data Selection
Description
The RWALL command can be used in the Subcase Information section to select rigid walls for
geometric nonlinear analysis.
Format
RWALL = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification of an RWALADD bulk data entry


or, if no RWALADD bulk data entry exists with this
SID, the set identification of RWALL bulk data
entries.

Comments
1.

Only one RWALL entry can be present for each subcase. It can only be used in subcases
that contain an ANALYSIS = NLGEOM entry.

2.

If the SID referenced by the RWALL subcase information entry matches with the SID
defined for an RWALADD bulk data entry, then the information on this entry alone is
selected. However, if no RWALADD bulk data entry has the referenced SID defined, then
any XHSIT bulk data entries that have this SID defined will be selected.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

297

SDAMPING
Subcase Information Entry
SDAMPING - Data Selection
Description
The SDAMPING command can be used in the Subcase Information section to apply modal
damping as a function of natural frequency in modal solutions.
Format
SDAMPING (type) = option

Argument

Option

Description

type

< STRUCTURE, FLUID >


Default = STRUCTURE

The referenced bulk data entry is applied to the


structural (STRUCTURE) or fluid (FLUID) portion of
the model.

option

< SID >

SID: Set identification of a TABDMP1 bulk data


entry.

No default
Comments
1.

SDAMPING can only be used in modal transient, modal frequency response and modal
complex eigenvalue analyses; and must reference a TABDMP1 bulk data entry.

2.

Only one SDAMPING entry of each type can be defined for each subcase.

3.

If only one type of SDAMPING entry is defined (either SDAMPING(STRUCTURE) or


SDAMPING(FLUID)), this definition will be used for both the structure and the fluid portion
of the model.

4.

If present above the first subcase, it is applied to each modal frequency or modal
transient subcase without an SDAMPING entry.

5.

To achieve identical displacements in Modal frequency response or Modal transient


analyses when the SDAMPING bulk data entry is used instead of PARAM, G, the steps
described here can be followed:
The TYPE field in the TABDMP1 bulk data entry should be set to CRIT. This TABDMP1 bulk
data entry is referenced by the SDAMPING subcase information entry.
Set the damping value (field gi) in the TABDMP1 bulk data entry equal to half of the
value of PARAM, G (that is set the constant value to C/C0).
Set PARAM, KDAMP,-1.

298

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SEINTPNT
Subcase Information Entry
SEINTPNT - Selection of Super Element Internal Point
Description
The SEINTPNT command can be used in the Subcase Information section to select a set of
interior DOF of super elements to be converted to exterior DOF.
Format
SEINTPNT = option
Example
SEINTPNT = 100
BEGIN BULK
SET,100,GRIDC,
+,10643,T1,10643,T2,10643,T3
GRID 10643 1 234 55 322

Argument

Option

Description

option

<SID>

SID refers to the ID of a bulk card SET of type GRIDC.

No default
Comments
1.

SEINTPNT can be used when CMS super elements in .h3d files are present in residual runs.
After the conversion, these DOF are part of the analysis DOF and can be used as
connection points, load DOF, response DOF during optimization.

2.

SEINTPNT is not supported for fluid grids.

3.

GRID point information for interior grids (that are to be converted to exterior grids) should
be included in the GRID bulk data entry, which in turn should be included in the solver
deck if SEINTPNT is used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

299

SOLVTYP
Subcase Information Entry
SOLVTYP - Solver Selection
Description
The SOLVTYP command can be used in the Subcase Information section to select the solver
for linear and nonlinear static subcases, nonlinear geometric implicit static subcase
(ANALYSIS=NLGEOM), and nonlinear geometric implicit dynamic subcase (ANALYSIS=IMPDYN).

Format
SOLVTYP = option

Argument

Option

Description

option

< SID >

SID: Set identification of an SOLVTYP bulk data entry.


Selects a SOLVTYP bulk data entry that is used to
define various settings for the solver, such as
different pre-conditioners and convergence criteria
for the solver.

Comments
1.

Only one SOLVTYP entry can be defined for each linear and nonlinear static subcases or
nonlinear geometric implicit subcase.

2.

If present above the first subcase, it is applied to all compatible linear and nonlinear
static subcases and nonlinear geometric implicit subcases. For more details on subcase
type and solver compatibility, refer to the SOLVTYP bulk data entry.

3.

If SOLVTYP is present in a subcase, a solver, specified by the referenced SOLVTYP in the


bulk data, is used in the solution of linear and nonlinear static subcases and nonlinear
geometric implicit subcases. The option selects the SOLVTYP bulk data entry that can be
used to define alternate settings such as different pre-conditioners and convergence
criteria for the solver.

4.

In optimization, if the responses DRESP1, RTYPE = DISP, LAMA, STESS, STRAIN,


CSTRESS, CSTRAIN, CFAILURE, or FORCE are present the solver is automatically reverted
to the direct solver.

5.

The iterative solver is a preconditioned conjugate gradient solver. A Factored


Approximate Inverse Preconditioner is the default method. This solver is also SMP
parallelized.

6.

The performance of the iterative solver depends on the conditioning of the stiffness
matrix. For compact solid models, the iterative solver may perform considerably better
than the direct solver in terms of memory usage and elapsed times for a single linear

300

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

static subcase. In the case of multiple linear static subcases, the iterative solver may
perform worse than the direct solver. The break-even point is at about 4-6 subcases.
The performance depends on model, hardware, operating system, and potentially the
system load.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

301

SPC
Subcase Information Entry
SPC - Data Selection
Description
The SPC command can be used in the Subcase Information section to select a single-point
constraint set.
Format
SPC = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification of an SPCADD bulk data entry or,


if no SPCADD bulk data entry exists with this SID,
the set identification of SPC or SPC1 bulk data
entries.

Comments
1.

Only one SPC entry can be present for each subcase.

2.

If the SID referenced by the SPC subcase information entry matches with the SID defined
for an SPCADD bulk data entry, then the information on this entry alone is selected.
However, if no SPCADD bulk data entry has the referenced SID defined, then any SPC or
SPC1 bulk data entries that have this SID defined will be selected.

3.

If present above the first subcase, it is the default for each subcase without an SPC
command, with the exception of linear buckling analysis subcases. Linear buckling
analysis subcases inherit the SPC information from the referenced static subcase.

4.

SPC may be set to 0 to override the default in subcases where no SPC is required.

5.

SPC must be present for linear static solutions. The SID may be set to 0 to run linear
static solutions with no constraints.

302

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

STATSUB
Subcase Information Entry
STATSUB - Subcase Selection
Description
The STATSUB command can be used in the Subcase Information section to select a static
solution subcase.
Format
STATSUB(type) = option

Argument

Option

Description

type

<BUCKLING, BUCKLING:
PRELOAD,
PRETENS,
STRUCTURE>
PRELOAD:
Default =
BUCKLING
PRETENS:

Referenced static subcase is used in forming


the geometric stiffness needed for the linear
buckling solution.
Referenced static subcase defines a preload.
Referenced static subcase introduces
pretensioning loads on bolts. (See comment
4).

STRUCTURE: Referenced static subcase will determine the


CONTACT / GAP status for a heat transfer
analysis (See comment 6).
option

< SID >

SID:

Subcase identification number of a static


solution subcase. (See comment 5).

No default
Comments
1.

A METHOD entry to define the eigenvalue extraction method is required in addition to a


STATSUB entry for a linear buckling solution subcase.

2.

A linear buckling solution cannot be performed on a linear static subcase that uses inertia
relief.

3.

STATSUB(PRELOAD) is supported for linear static, normal modes, and direct frequency
response solution sequences.

4.

STATSUB(PRETENS) is supported for linear and nonlinear static subcases. Other subcase
types can use STATSUB(PRELOAD), which refers to a pretension subcase, in order to
incorporate the effect of pretensioning on natural frequencies, dynamic solutions, and so

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

303

on.
5.

STATSUB(PRETENS) can only reference a subcase that precedes the current subcase in
the input deck.

6.

STATSUB(STRUCTURE) is supported for both steady-state and transient heat transfer


solution sequences.

7.

STATSUB(PRELOAD) can be used with the AMSES eigensolver.

304

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SUBCASE
Subcase Information Entry
SUBCASE - Subcase Selection
Description
The SUBCASE command can be used in the Subcase Information section to indicate the start
of a new subcase definition.
Format
SUBCASE = integer

Argument

Description

integer

Subcase identification number (SID)


No default (Integer > 0)

Comments
1.

Each subcase must be declared with a separate SUBCASE header and a unique SID.

2.

The SUBCASE header is not needed if there is just one subcase.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

305

SUBCOM
Subcase Information Entry
SUBCOM - Combination Subcase Delimiter
Description
Delimits and identifies a combination subcase.
Format
SUBCOM = n
Example
SUBCOM = 125

Argument

Description

Subcase identification number


(Integer > 2)

Comments
1.

A SUBSEQ command must follow this command.

2.

SUBCOM may only be used with STATIC subcases.

3.

Output requests above the subcase level will be used.

4.

If the referenced subcases contain thermal loads or element deformations, you must
define the temperature field in the SUBCOM with a TEMP(LOAD) command or the element
deformations with a DEFORM command.

5.

If the reference subcases contain STATSUB(PRELOAD), then all of the referenced


subcases must contain the same STATSUB(PRELOAD); the same STATSUB(PRELOAD)
should also be used in the SUBCOM.

306

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SUBMODEL
Subcase Information Entry
SUBMODEL - Subcase-specific Model Selection
Description
The SUBMODEL entry can be used in the Subcase Information section to select a submodel as
a set of elements. Subcase entries specific to the selected element set can be used to solve
the submodel without affecting the rest of the structure.
Format
SUBMODEL, SID, SID_r

Argument

Value

Description

SID

<integer>0>

Specifies the SID of a SET of elements that defines the


submodel.

SID_R

<integer>0>,
NONE, blank

<integer>0>

Specifies the SID of a set of rigid


elements to be included with the
submodel.

NONE:

The subcase containing this SUBMODEL


entry will skip all rigid elements in the
input deck.

blank:

If SID_r is blank, the subcase containing


this SUBMODEL entry will include all rigid
elements defined in the input deck.

Comments
1.

A SUBMODEL entry can only be defined within a subcase and cannot be specified above
the first subcase.

2.

The SUBMODEL entry does not automatically apply the specific attributes (loads,
constraints and so on) to the defined submodel. It is your responsibility to specify
corresponding attributes that apply exclusively to the subcase-specific model defined via
SUBMODEL.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

307

SUBSEQ
Subcase Information Entry
SUBSEQ - Subcase Sequence Coefficients
Description
Gives the coefficients for forming a linear combination of the previous static subcases.
Format
SUBSEQ=R1 [, R2, R3, ..., Rn]
Example
SUBSEQ=1.0, -1.0, 0.0, 2.0

Argument

Description

Ri

Coefficients of the previously occurring static subcases.


(Real)

Comments
1.

Can only appear after a SUBCOM command.

2.

R1 to Rn refer to the immediately preceding statis subcases. Rn is applied to the most


recently appearing static subcase, R(n-1) is applied to the second most recently
appearing static subcase, and so on. The embedded comments ($) describe the following
example:
DISPL = ALL
SUBCASE 1
SUBCASE 2
SUBCOM 3
SUBSEQ = 1.0, -1.0 $ SUBCASE 1 - SUBCASE 2
SUBCASE 11
SUBCASE 12
SUBCOM 13
SUBSEQ = 0.0, 0.0, 1.0, -1.0 $ SUBCASE 11 - SUBCASE 12
or
SUBSEQ = 1.0, -1.0 $ EQUIVALENT TO PRECEDING COMMAND.

308

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

USE ONLY ONE.

Altair Engineering

SUPORT1
Subcase Information Entry
SUPORT1 - Data Selection
Description
The SUPORT1 command can be used in the Subcase Information section to select the fictitious
support set to be applied to the model.
Format
SUPORT1 = option

Argument

Options

Description

option

< SID >

SID: Set identification of a SUPORT1 bulk data entry.

No default
Comments
1.

SUPORT1 entries will not be used unless selected in the Subcase Information section by
the SUPORT1 command.

2.

SUPORT1 entries will be applied in all subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

309

TEMPERATURE
Subcase Information Entry
TEMPERATURE Temperature Set Selection
Description
Selects the temperature set to be used in either material property calculations or thermal
loading.
Format
TEMPERATURE (type) = option
Examples
TEMPERATURE(LOAD)=15
TEMP(MATERIAL)=7
TEMPERATURE=7

Argument

Option

Description

type

<INITIAL,
MATERIAL,
LOAD, BOTH>

INITIAL:

The selected temperature set will be used


to determine initial temperature
distribution.

Default = BOTH

MATERIAL:

The selected temperature set will be used


to determine temperature-dependent
material properties indicated on the MATTi
bulk data entries.
In addition, the SUBCASE ID of a thermal
analysis SUBCASE can be specified. The
calculated temperature field is then used to
determine temperature-dependent material
properties indicated on the MATTi bulk data
entries.

option

< SID >

LOAD:

The selected temperature set will be used


to determine an equivalent static load.

BOTH:

Both MATERIAL and LOAD will use the same


temperature set.

SID:

Set identification number of TEMP or TEMPD


bulk data entries.

No default

310

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Only one of TEMPERATURE(MATERIAL) or TEMPERATURE (INITIAL) is allowed in any


problem and should be specified above the subcase level (although it will be accepted
inside the subcase).

2.

TEMPERATURE(BOTH) and TEMPERATURE(LOAD) can be used before the subcase level or


inside the subcase. If used before the subcase level, it will apply to all subcases that do
not have their own TEMP(BOTH) or TEMP(LOAD) command.

3.

If multiple temperature-dependent material requests are made (for example, by using


TEMP(MATERIAL) and TEMP(BOTH)), then the last request will be used to define material
properties.

4.

The total load applied will be the sum of external (LOAD command), thermal (TEMP(LOAD)
command) and constrained displacement (SPC command) loads.

5.

Static and thermal loads should have unique set identification numbers.

6.

In linear static analysis, temperature strains are calculated with:

where, A(T0 ) is the thermal expansion coefficient defined on the MATi bulk data entries, T
is the load temperature defined with TEMPERATURE(LOAD), and T0 is the initial temperature
which is defined in one of the following ways:
If TEMPERATURE(INITIAL) and TREF (specified on the MATi or PCOMPi cards) are
specified, then the TEMPERATURE(INITIAL) set will be used as the initial temperature
to calculate both the thermal loads and the material properties.
If TEMPERATURE(MATERIAL) and TREF are specified, then TREF will be used as the initial
temperature in calculating the thermal load and the TEMPERATURE (MATERIAL) set will
be used for the calculation of the material properties.
If neither TEMPERATURE(MATERIAL) nor TEMPERATURE(INITIAL) are specified, TREF will
be used to calculate both the thermal load and the material properties.
If none of TEMPERATURE(INITIAL),TEMPERATURE(MATERIAL), and TEMPERATURE(BOTH)
is present, TREF will be used to calculate the load. The material properties will be
obtained from the MATi entry. The MATTi is not used in this case.
7.

In versions of OptiStruct prior to 8.0, thermal loads were selected in the Subcase
Information section using the LOAD data selector. In version 8.0, the TEMPERATURE data
selector was added to perform this function. It is possible to revert to the old behavior
mode by setting the LOADTEMP option to SHAREID in the OptiStruct Configuration File.

8.

TEMPERATURE(LOAD) or TEMPERATURE(MATERIAL) can point to a heat transfer subcase or


TSTRU ID. The temperature field from a steady state heat transfer analysis or at the final
time step of a transient heat transfer analysis will be used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

311

TSTEP
Subcase Information Entry
TSTEP Transient Time Step Set Selection
Description
The TSTEP command can be used in the Subcase Information section to select integration for
transient analysis.
Format
TSTEP (type) = option
Example
TSTEP = 731
TSTEP (FOURIER) = 755

Argument

Option

Description

type

<TIME, FOURIER>

TIME:

The transient response is computed by


time step integration in the time domain.

FOURIER:

The transient response is computed in the


frequency domain using the Fourier
transform method.

SID:

Set identification number of a TSTEP bulk


data entry.

Default = TIME

option

< SID >


No default

Comments
1.

A TSTEP entry must be selected to execute a transient analysis.

2.

A TSTEP entry can also be used to execute a transient thermal analysis (only for
type=TIME or Default).

3.

For the application of time-dependent loads in modal frequency response analysis, a


TSTEP bulk data entry must be selected by the TSTEP (FOURIER) command. The timedependent loads will be recomputed in the frequency domain by a Fourier transform.

312

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TSTEPNL
Subcase Information Entry
TSTEPNL Nonlinear Implicit Dynamics Time Step Set Selection
Description
The TSTEPNL command can be used in the Subcase Information section to select integration
and other parameters for nonlinear implicit dynamics analysis.
Format
TSTEPNL = option
Example
TSTEPNL = 731

Argument

Option

Description

option

< SID >

SID:

Set identification number of a TSTEPNL


bulk data entry.

No default
Comments
1.

A TSTEPNL entry must be selected to execute a nonlinear implicit dynamic analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

313

TSTRU
Subcase Information Entry
TSTRU - Temperature Set ID for Structural Analysis
Description
The TSTRU command can be used in the Subcase Information section to assign a temperature
set identification number to the resulting nodal temperatures of a steady-state heat transfer
analysis or the last time step of a transient heat transfer analysis.
Format
TSTRU = option

Argument

Option

Description

option

< SID >

SID:

Default = Subcase ID

This is a temperature set identification number.


It may be referenced from a static analysis
subcase, in which case the resulting nodal
temperatures of a steady-state heat transfer
analysis or the last time step of a transient
heat transfer analysis are considered as applied
loads for the static analysis.

Comments
1.

TSTRU is only valid in a heat transfer subcase.

2.

If TSTRU does not explicitly appear in a heat transfer subcase, then the Subcase ID is
used as the default.

3.

A temperature set from a heat transfer analysis will override any temperature set defined
by the bulk data entries TEMP or TEMPD.

314

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

WEIGHT
Subcase Information Entry
WEIGHT - Optimization Parameter
Description
The WEIGHT command can be used in the Subcase Information section to define a weighting
factor (multiplier) for the compliances of individual linear static solution subcases, which are
used in the calculation of the "weighted compliance" and "combined compliance index"
optimization responses.
Format
WEIGHT = value

Argument

Description

value

The multiplier to be used for the compliance of this subcase in the


calculation of "weighted compliance" or "combined compliance index."
Default = 1.0 (Real)

Comments
1.

Refer to the Responses page of the User's Guide for more information on "weighted
compliance" and "combined compliance index" optimization response calculations.

2.

WEIGHT is only used in conjunction with DRESP1, RTYPE = WCOMP, COMB.

3.

If a WEIGHT is not defined in any subcase, but a DRESP1 with RTYPE = WCOMP or COMB
exists, all static subcases are assigned a WEIGHT of 1.0 by default.

4.

This entry is represented as an optimization response in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

315

XHIST
Subcase Information Entry
XHIST Data Selection
Description
The XHIST command can be used in the Subcase Information section to select time history
output for geometric nonlinear analysis.
Format
XHIST = option

Argument

Option

Description

option

< SID >

SID:

No default

Set identification of an XHISTADD bulk data entry


or, if no XHISTADD bulk data entry exists with this
SID, the set identification of XHIST bulk data
entries.

Comments
1.

Only one XHIST entry can be present for each subcase. It can only be used in subcases
that contain an ANALYSIS = NLGEOM entry.

2.

If the SID referenced by the XHIST subcase information entry matches with the SID
defined for an XHISTADD bulk data entry, then the information on this entry alone is
selected. However, if no XHISTADD bulk data entry has the referenced SID defined, then
any XHSIT bulk data entries that have this SID defined will be selected.

316

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

XSTEP
Subcase Information Entry
XSTEP Explicit Analysis Parameter Selection
Description
The XSTEP command can be used in the Subcase Information section to activate the explicit
solution method for this subcase and to select the parameters used for explicit analysis.
Format
XSTEP = option

Argument

Option

Description

option

< SID >

SID:

Set identification of an XSTEP bulk data entry.

No default
Comments
1.

XSTEP bulk data entries will not be used unless selected in the Subcase Information
section.

2.

The XSTEP command is supported in explicit analysis and optimization subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

317

Bulk Data Section

318

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ACCLR
Bulk Data Entry
ACCLR Accelerometer for Geometric Nonlinear Analysis
Description
Defines accelerometer for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

AC C LR

AID

GID

FC UT

(5)

(6)

(7)

(8)

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

AC C LR

100

34

100.0

(5)

(6)

Field

Contents

AID

Unique accelerometer identification number.

(7)

(8)

(Integer > 0)
GID

Grid point identification number.


(Integer > 0)

FCUT

Cutoff frequency.
(Real > 0)

Comments
1.

The accelerometer option computes a filtered acceleration in the output system.

2.

These filtered accelerations provided by an accelerometer are used in either a SENSOR or


in post-processing acceleration time history without aliasing problems.

3.

A 4-pole Butterworth filter is used.

4.

The recommended value for FCUT is 1650 Hz (1.65 ms-1) to obtain a class 1000 SAE
filtering.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

319

5.

In addition to these filtered accelerations, the accelerometer also allows the output of
the integrals of X, Y, and Z of the raw accelerations projected to the output coordinate
system to time history. These quantities are not used by SENSOR.

6.

Note that if the coordinates are moving, the integrals of X, Y, and Z raw accelerations
projected to the output coordinate system are not the same as the velocities projected
to the output coordinate system, as described in XHIST. Computation of these integrals
in a post-processor allows retrieving the accelerations projected to the output coordinate
system without aliasing problems. Integration and differentiation are acting like another
filter on top of the 4-pole Butterworth.

7.

This card is unsupported in HyperMesh.

320

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ACMODL
Bulk Data Entry
ACMODL Fluid-Structure Interface Parameters
Description
Defines model parameters for the Fluid-Structure interface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

AC MODL

INTER

INFOR

FSET

SSET

NORMAL

INTOL

(7)

(8)

(9)

SKNEPS

DSKNEPS

(10)

SRC HUNIT MAXSGRID

Field

Contents

INTER

Fluid-structure interface type.


Default = DIFF (IDENT or DIFF)

INFOR

Defines whether grids or elements identified by FSET and SSET are to be


used to define the fluid-structure interface.
Default = GRID (GRID or ELEMENT)

FSET

ID of a SET of fluid elements or grids to be considered for the interface.


Default = blank (Integer)

SSET

ID of a SET of structural elements or grids to be considered for the interface


Default = blank (Integer)

NORMAL

Fluid normal tolerance.


Default = 1.0 when INTER = DIFF;
Default = 0.001 when INTER = IDENT (Real)

SKNEPS

Fluid skin growth tolerance (See comments 4 and 5).


Default = 0.5 (Real)

DSKNEPS

Secondary fluid skin growth tolerance (See comments 4 and 5).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

321

Field

Contents
Default = 1.5 * SKNEPS (Real)

INTOL

Tolerance of inward normal.


Default = 0.5 (Real)

SRCHUNIT

Search units. ABS for absolute model units or REL for relative model units
based on element size.
Default = REL (ABS or REL)

MAXSGRID

The maximum number of structural grids that can be interfaced with one fluid
element face.
Default = 200 (Integer > 0)

Comments
1.

ACMODL card is optional in the deck. If provided, only one ACMODL card is allowed.

2.

For INTER=IDENT, the interface would be calculated based on a grid to grid match
between fluid and structural parts. For INTER=IDENT, INFOR must be GRID or blank. Each
grid specified on the FSET/SSET must be able to find a matching interface grid. If either
FSET or SSET is not provided, a searching algorithm would find the grids on the skin of
the surface.

3.

For INTER=DIFF, if FSET/SSET is provided, the skin of the surface would be based on the
set. If either FSET or SSET is not provided, a searching algorithm would find the skin of
the surface. The searching algorithm for this case is based on the normal distance from
the fluid face. When INTER=DIFF, a grid to grid match is no longer a requirement.

4.

The search box is described by several parameters:

322

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

The height of the searching box is based on the NORMAL parameter. If L is the
smallest edge of the fluid element face, the height of the search box would be NORMAL
x L.
SKNEPS represents the enlargement of the plane of the fluid surface used to define the
search box. The diagonal distance, D, from the center of the fluid surface to each
surface grid is pushed out by (1.0+SKNEPS) x D.
DSKNEPS represents a secondary enlargement of the plane of the fluid surface used to
define the search box if SKNEPS fails to find ANY structural elements. The diagonal
distance from the center of the fluid surface to each surface grid is pushed out by (1.0
+DSKNEPS) x D.
INTOL represents a normal direction into the fluid for the case when the fluid protrudes
past the structural interface. It is defined as INTOL x L, where L is the smallest edge
of the fluid element surface.
5.

The value required in the secondary fluid skin growth tolerance (DSKNEPS) field must
always be greater than the value of the fluid growth tolerance (SKNEPS).
If the required value of DSKNEPS is less than SKNEPS, then an ERROR message will be
output and the run will be terminated.
If the DSKNEPS field is left blank, a default value equal to 1.5 * SKNEPS is assigned to
it.

6.

This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

323

ACSRCE
Bulk Data Entry
ACSRCE Acoustic Source
Description
Defines acoustic source as a function of power vs. frequency.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

AC SRC E

SID

EXC ITEID

DELAY

DPHASE

TP

RHO

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

AC SRC E

111

29

-0.2

87

14

1.0

15

Field

Contents

SID

Identification number of a dynamic load set.

(9)

(10)

No default (Integer > 0)


EXCITEID

Identification number of an SLOAD entry set that defines A.


No default (Integer > 0)

DELAY

Defines time delay . If it is a non-zero integer, it represents the


identification number of a DELAY bulk data entry that defines . If it is
real, then it directly defines the value of that will be used for all
degrees-of-freedom that are excited by this dynamic load entry.
Default = 0 (Integer > 0, or Real)

DPHASE

324

Defines phase . If it is a non-zero integer, it represents the identification


number of a DPHASE bulk data entry that defines . If it is real, then it

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
directly defines the value of that will be used for all degrees-of-freedom
that are excited by this dynamic load entry.
Default = 0 (Integer > 0, or Real)

TP

Set identification number of the TABLED1, TABLED2, TABLED3, or TABLED4


entry that gives P(f).
Default = 0 (Integer > 0)

RHO

Fluid Density
No default (Real > 0.0)

Bulk modulus of fluid.


No default (Real > 0.0)

Comments

1.

where,
2.

Dynamic load sets must be selected in the I/O Options or Subcase Information sections
with the command DLOAD = SID.

3.

SID must be unique with respect to other dynamic load sets, that is ACSRCE, DLOAD,
RLOAD1, RLOAD2, TLOAD1, and TLOAD2 entries.

4.

The referenced EXCITEID, DELAY and DPHASE entries must specify fluid points only.

5.

If either DELAY or DPHASE are blank or zero, the corresponding

Altair Engineering

or

will be zero.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

325

ASET
Bulk Data Entry
ASET Boundary Degrees-of-Freedom of a Superelement Assembly
Description
Defines the boundary degrees-of-freedom of a superelement assembly for matrix reduction.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ASET

G1

C1

G2

C2

G3

C3

G4

C4

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

ASET

564

765

4561

Field

Contents

Gi

Grid or scalar point identification numbers.

(8)

(9)

(10)

No default (Integer > 0)


Ci

Component numbers.
(Integer zero or blank for scalar points, or up to 6 unique digits (0 < integer
< 6) may be placed in the field with no embedded blanks for grid points.
The components refer to the coordinate system referenced by the grid
points.)

Comments
1.

Refer to the User's Guide section on The Direct Matrix Approach for more information on
the use of this card.

2.

A fatal error will be issued if the input contains ASET or ASET1, but PARAM, EXTOUT is
not given.

326

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

4.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

327

ASET1
Bulk Data Entry
ASET1 Boundary Degrees-of-Freedom of a Superelement Assembly, Alternate Form
Description
Defines the boundary degrees-of-freedom of a superelement assembly for matrix reduction.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ASET1

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ASET1

123

34

88

12

19

70

1234

65

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

ASET1

G1

"THRU"

G2

ASET1

123456

88

THRU

207

328

(6)

(7)

(8)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

Field

Contents

Component number.
(Integer zero or blank for scalar points, or up to 6 unique digits (0 < integer
< 6) may be placed in the field with no embedded blanks for grid points. The
components refer to the coordinate system referenced by the grid points.)

Gi

Grid or scalar point identification numbers.


(Integer > 0, for THRU option, G1 < G2)

Comments
1.

If the alternate format is used, all points in the sequence G1 through G2 are not required
to exist, but there must be at least one boundary degree-of-freedom for the model, or a
fatal error will result. Any grids implied in the THRU that do not exist will collectively
produce a warning message, but will otherwise be ignored.

2.

Refer to the User's Guide section on The Direct Matrix Approach for more information on
the use of this card.

3.

A fatal error will be issued if the input contains ASET or ASET1, but PARAM, EXTOUT is
not given.

4.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
MIXED, it is allowed that when grid lists are provided for a given component, that the grid
references be either scalar points (SPOINT) or structural grid points (GRID) when the
component is 0, 1 or blank; interpreting all of these as 0 for scalar points and as 1 for
structural grids. When SPSYNTAX is set to STRICT it is required for grid/component pairs
(G#/C#) that the component be 0 or blank when the grid references are to scalar points
(SPOINT), and that the component be > 1 when the grid references are to structural grid
points (GRID). When the component is greater than 1, the grid references must always
be a structural grid (GRID).

5.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

329

BEAD
The BEAD bulk data entry will no longer be supported for the definition of topography
optimization. All definitions must be provided using the DTPG bulk data entry. HyperMesh will
continue to read BEAD entries, but will convert them into DTPG entries.
Information regarding the BEAD entry can be found in the Previously Supported Input section
of the Reference Guide.

330

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BEGIN
Bulk Data Entry
BEGIN Indicates the beginning of data input for a specific entity.
Description
The BEGIN bulk data entry indicates the beginning of data that is used to describe a specific
entity (or entities) for inclusion in a model. The BEGIN entry is used in conjunction with the
END entry to define the data required for a specific entity.
Format
(1)

(2)

(3)

(4)

BEGIN

TYPE

NAME

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

BEGIN

FEMODEL

Bumper

(1)

(2)

(3)

(4)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(5)

(6)

(7)

(8)

(9)

(10)

BEGIN HYPRBEAM Square

Field

Contents

TYPE

Specifies the entity type that will be defined by the BEGIN data entry (see
Comment 2).
(HYPRBEAM or FEMODEL)

NAME

This field specifies the name of the entity that is defined by the BEGIN entry
(see Comment 2).
(Character String)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

331

Comments
1.

The BEGIN and END bulk data entries are used in conjunction to define an entity within
the full model.

2.

TYPE = HYPRBEAM:
Data required for the definition of an arbitrary beam section will be specified between the
BEGIN and END data entries.
TYPE = FEMODEL:
In a model containing multiple parts, the parts are included within the full model specifying
part data between the BEGIN and END bulk data entries (the INCLUDE entry can also be
used for part data referencing). The name of the included part should be specified in the
NAME field.

3.

The INCLUDE entry, similar to almost any other bulk data entry, is allowed between BEGIN
and END entries. However, BEGIN and END should exist in the same file.

4.

Models are often defined in separate files, and the block (BEGIN END) contains only
INCLUDE entries. It is possible to duplicate a single part by including the same file(s) in
different BEGIN-END blocks.

5.

There can be multiple sections of arbitrary beam data; one for each beam section.

6.

An example set of data for the definition of an arbitrary beam section is as follows:
BEGIN,HYPRBEAM,SQUARE
$
GRIDS,1,0.0,0.0
GRIDS,2,1.0,0.0
GRIDS,3,1.0,1.0
GRIDS,4,0.0,1.0
$
CSEC2,10,100,1,2
CSEC2,20,100,2,3
CSEC2,30,100,3,4
CSEC2,40,100,4,1
$
PSEC,100,1000,0.1
$
END,HYPRBEAM

332

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BLKHDF
Bulk Data Entry
BLKHDF Blank Holder Force for One-Step Stamping Simulation
Description
Defines the blank holder force in a one-step stamping simulation.
Format
(1)

(2)

(3)

(4)

(5)

BLKHDF

BHID

MU

FORC E

TOGGLE

(6)

(7)

(8)

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

BLKHDF

0.3

3.0

0.0

Field

Contents

BHID

Blank holder identification number.

(6)

(7)

(8)

No default (Integer > 0)


MU

Coefficient of friction.
No default (Real > 0.0)

FORCE

Blank holder force.


No default (Real)

TOGGLE

Flag assigned based on option (Pressure or Tonnage).


0.0 Uniform pressure is applied on blank holder.
1.0 Net force is applied on blank holder.

Comments
1.

This entry is only valid with an @HyperForm statement in the first line of the input file.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

333

BMFACE
Bulk Data Entry
BMFACE Barrier Mesh Face
Description
Defines quad or tria faces that are in turn used to define a barrier to limit the total
deformation for free-shape design regions.
Format
(1)

(2)

(3)

(4)

(5)

(6)

BMFAC E

BMID

G1

G2

G3

G4

(7)

(8)

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

BMFAC E

10

8203

8204

8100

(6)

(7)

(8)

Field

Contents

BMID

Barrier mesh identification number. Referenced from a DSHAPE bulk data


entry.
No default (Integer > 0)

G#

Grid point identification number of connection points. G1, G2, and G3 are
required to define tria faces, G4 is required to define quad faces.
No default (Integer > 0, all unique)

Comments
1.

334

Grid points used in the definition of BMFACE entries cannot be used to define structural
elements.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BNDFIX
Bulk Data Entry
BNDFIX Boundary Degrees-of-Freedom of a Superelement Assembly
Description
Defines the degrees-of-freedom to be fixed during DMIG generation using CMSMETH card.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

BNDFIX

GID1

IC 1

GID2

IC 2

GID3

IC 3

(8)

(9)

(10)

Example

(1)

(2)

(3)

BNDFIX

1220

12345

(4)

(5)

(6)

Field

Contents

GIDi

Grid of scalar point identification numbers.

(7)

(8)

(9)

(10)

No default (Integer > 0)


ICi

Component numbers.
No default (Integer > 0)

Comments
1.

BNDFIX and BSET are equivalent.

2.

ASET, BNDFIX and BNDFREE; all three are not allowed in the same deck.

3.

If BNDFREE and ASET are present, the DOFs associated with ASET would be in BNDFIX;
except the DOF assigned to BNDFREE.

4.

If BNDFIX and ASET are present, the DOFs associated with ASET would be in BNDFREE;
except the DOF assigned to BNDFIX.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

335

BNDFIX1
Bulk Data Entry
BNDFIX1 Fixed Boundary Degrees-of-Freedom of a Superelement Assembly
Description
Defines the fixed (B-set) degrees-of-freedom to be fixed during DMIG generation using
CMSMETH card.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BNDFIX1

GID1

GID2

GID3

GID4

"thru"

GID6

GID7

GID8

GID9

etc.

Example

(1)

(2)

(3)

(4)

(5)

(6)

BNDFIX1

12345

1220

1221

THRU

1229

Field

Contents

Component numbers.

(7)

(8)

(9)

(10)

No default (Integer > 0 or blank). Zero or blank for SPOINT and any unique
combination of integers 1 through 6 for grid points with no embedded
blanks.
GIDi

Grid of scalar point identification numbers.


No default (Integer > 0)

THRU

336

Keyword to allow a range of GID. THRU can be in any field.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

BNDFIX1 and BSET1 are equivalent.

2.

The combination of the three ASET/ASET1, BNDFIX/BNDFIX1 and BNDFREE/BNDFRE1 are


not allowed together in the same input data.

3.

If BNDFREE/BNDFRE1 and ASET/ASET1 are present, the DOFs associated with ASET will be
in the B-set; except the DOF assigned to BNDFREE which will be in the C-set.

4.

If BNDFIX/BNDFIX1 and ASET/ASET1 are present, the DOFs associated with ASET would
be in C-set; except the DOF assigned to BNDFIX which will be in the B-set.

5.

Multiple thru sequences can be used on a single card, and can span across continuation
lines.

6.

If the "thru" comment is used, G1 and G2 must exist, but the grid points between G1 and
G2 are not required to exist.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

337

BNDFRE1
Bulk Data Entry
BNDFRE1 Free Boundary Degrees-of-Freedom of a Superelement Assembly
Description
Defines the free (C-set) degrees-of-freedom to be fixed during DMIG generation using
CMSMETH card.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

BNDFRE1

GID1

GID2

GID3

GID4

"thru"

GID6

GID7

GID8

GID9

etc.

(7)

(8)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

BNDFRE
1

12345

1220

1221

thru

1229

Field

Contents

Component numbers.

(9)

(10)

No default (Integer > 0 or blank). Zero or blank for SPOINT and any unique
combination of integers 1 through 6 for grid points with no embedded blanks.
GIDi

Grid of scalar point identification numbers.


No default (Integer > 0)

THRU

338

Keyword to allow a range of GID. THRU can be in any field.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

BNDFRE1 and CSET1 are equivalent.

2.

The combination of the three ASET/ASET1, BNDFIX/BNDFIX1, and BNDFREE/BNDFRE1 are


not allowed together in the same input data.

3.

If BNDFREE/BNDFRE1 and ASET/ASET1 are present, the DOFs associated with ASET will be
in the B-set; except the DOF assigned to BNDFREE which will be in the C-set.

4.

If BNDFIX/BNDFIX1 and ASET/ASET1 are present, the DOFs associated with ASET would
be in C-set; except the DOF assigned to BNDFIX which will be in the B-set. Any number of
continuations may appear.

5.

Multiple thru sequences can be used on a single card, and can span across continuation
lines.

6.

If the "thru" comment is used, G1 and G2 must exist, but the grid points between G1 and
G2 are not required to exist.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

339

BNDFREE
Bulk Data Entry
BNDFREE Boundary Degrees-of-Freedom of a Superelement Assembly
Description
Defines the degrees-of-freedom to be fixed during DMIG generation using CMSMETH card.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

BNDFREE

GID1

IC 1

GID2

IC 2

GID3

IC 3

(8)

(9)

(10)

Example

(1)

(2)

(3)

BNDFREE

1220

12345

(4)

(5)

(6)

Field

Contents

GIDi

Grid of scalar point identification numbers.

(7)

(8)

(9)

(10)

No default (Integer > 0)


ICi

Component numbers.
No default (Integer > 0)

Comments
1.

BNDFREE and CSET are equivalent.

2.

ASET, BNDFIX and BNDFREE are not allowed in the same deck.

3.

If BNDFREE and ASET are present, the DOFs associated with ASET would be in BNDFIX;
except the DOF assigned to BNDFREE.

4.

If BNDFIX and ASET are present, the DOFs associated with ASET would be in BNDFREE;
except the DOF assigned to BNDFIX.

340

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BSET
Bulk Data Entry
BSET Boundary Degrees-of-Freedom of a Superelement Assembly
Description
BSET entry is equivalent to BNDFIX.
Refer to the documentation for the BNDFIX Bulk Data Entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

341

BSET1
Bulk Data Entry
BSET1 Fixed Boundary Degrees-of-Freedom of a Superelement Assembly
Description
BSET1 entry is equivalent to BNDFIX1.
Refer to the documentation for the BNDFIX1 Bulk Data Entry.

342

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CAABSF
Bulk Data Entry
CAABSF Frequency-dependant Fluid Acoustic Absorber Element
Description
Defines the frequency-dependant fluid acoustic absorber element in coupled fluid-structural
analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C AABSF

EID

PID

G1

G2

G3

G4

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

C AABSF

71

10

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PAABSF property entry.


No default (Integer > 0)

Gi

Grid point identification numbers of fluid connection points.


Default = blank (Integer > 0 or blank)

Input File - mdcaabsf.parm

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

343

$$
$$ Optistruct Input Deck Generated by HyperMesh Version : 10.0build60
$$ Generated using HyperMesh-Optistruct Template Version : 10.0-SA1-120
$$
$$
Template: optistruct
$$
$$
$
DISPLACEMENT(PHASE) = 1
OUTPUT,HGFREQ,ALL
OUTPUT,OPTI,ALL
OUTPUT,H3D,ALL
OUTPUT,PUNCH,ALL
$$------------------------------------------------------------------------------$
$$
Case Control Cards
$
$$------------------------------------------------------------------------------$
$
$HMNAME LOADSTEP
1"Piston_Load"
6
$
SUBCASE
1
LABEL Piston_Load
SPC =
12
METHOD(STRUCTURE) =
4
METHOD(FLUID) =
5
FREQUENCY =
3
DLOAD =
9
XYPUNCH DISP 1/
11(T1)
XYPUNCH DISP 1/
43(T1)
XYPUNCH DISP 1/
55(T1)
XYPUNCH DISP 1/
67(T1)
XYPUNCH DISP 1/
79(T1)
XYPUNCH DISP 1/
91(T1)
XYPUNCH DISP 1/
103(T1)
XYPUNCH DISP 1/
115(T1)
XYPUNCH DISP 1/
127(T1)
XYPUNCH DISP 1/
139(T1)
XYPUNCH DISP 1/
151(T1)
XYPUNCH DISP 1/
163(T1)
XYPUNCH DISP 1/
175(T1)
XYPUNCH DISP 1/
187(T1)
XYPUNCH DISP 1/
199(T1)
XYPUNCH DISP 1/
531(T1)
XYPUNCH DISP 1/
543(T1)
XYPUNCH DISP 1/
555(T1)
XYPUNCH DISP 1/
567(T1)
XYPUNCH DISP 1/
579(T1)
XYPUNCH DISP 1/
591(T1)
XYPUNCH DISP 1/
603(T1)
XYPUNCH DISP 1/
615(T1)
XYPUNCH DISP 1/
627(T1)
XYPUNCH DISP 1/
639(T1)
XYPUNCH DISP 1/
651(T1)
XYPUNCH DISP 1/
663(T1)
XYPUNCH DISP 1/
675(T1)
XYPUNCH DISP 1/
687(T1)
$
$HMSET
1
1 "pressure"
SET 1 = 43,55,67,79,91,103,115,
127,139,151,163,175,187,199,
531,543,555,567,579,591,603,
615,627,639,651,663,675,687,
6798
$
$$-------------------------------------------------------------$$ HYPERMESH TAGS
$$-------------------------------------------------------------$$BEGIN TAGS
$$END TAGS

344

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$
BEGIN BULK
ACMODL
$$
$$ Stacking Information for Ply-Based Composite Definition
$$
PARAM,AUTOSPC,YES
PARAM,POST,-1
$$
$$ DESVARG Data
$$
$$
$$ GRID Data
$$
GRID
9
GRID
10
GRID
11
GRID
12
GRID
13
GRID
14
GRID
15
GRID
16
GRID
17
GRID
18
GRID
19
GRID
20
GRID
21
GRID
22
GRID
23
GRID
24
GRID
25
GRID
26
GRID
27
GRID
28
GRID
29
GRID
30
GRID
31
GRID
32
GRID
33
GRID
34
GRID
35
GRID
36
GRID
37
GRID
38
GRID
39
GRID
40
GRID
41
GRID
42
GRID
43
GRID
44
GRID
45
GRID
46
GRID
47
GRID
48
GRID
49
GRID
50
GRID
51
GRID
52
GRID
53
GRID
54
GRID
55
GRID
56
GRID
57
GRID
58
GRID
59
GRID
60
GRID
61
GRID
62

Altair Engineering

0.492
0.0
-1.72-15
0.246
0.0
-8.59-16
0.0
0.0
0.0
-0.246 0.0
8.589-16
-0.492 0.0
1.718-15
-0.492 0.246
1.718-15
-0.492 0.492
1.718-15
-0.246 0.492
8.589-16
0.0
0.492
0.0
0.246
0.492
-8.59-16
0.492
0.492
-1.72-15
0.492
0.246
-1.72-15
0.0
0.246
0.0
-0.246 0.246
8.589-16
0.246
0.246
-8.59-16
0.492
-0.246 -1.72-15
0.492
-0.492 -1.72-15
0.246
-0.492 -8.59-16
0.0
-0.492 0.0
-0.246 -0.492 8.589-16
-0.492 -0.492 1.718-15
-0.492 -0.246 1.718-15
0.0
-0.246 0.0
0.246
-0.246 -8.59-16
-0.246 -0.246 8.589-16
0.246
5.049-29-.300073
-5.99-130.0
-.300073
-5.62-130.246
-.300073
0.246
0.246
-.300073
0.246
2.524-29-.600146
-1.2-12 0.0
-.600146
-1.12-120.246
-.600146
0.246
0.246
-.600146
0.246
2.919-29-0.90022
-1.79-120.0
-.900219
-1.68-120.246
-.900219
0.246
0.246
-0.90022
0.246
3.787-29-1.20029
-2.39-120.0
-1.20029
-2.24-120.246
-1.20029
0.246
0.246
-1.20029
0.246
4.733-29-1.50037
-3.0-12 0.0
-1.50037
-2.81-120.246
-1.50037
0.246
0.246
-1.50037
0.246
5.364-29-1.80044
-3.6-12 0.0
-1.80044
-3.37-120.246
-1.80044
0.246
0.246
-1.80044
0.246
6.311-29-2.10051
-4.2-12 0.0
-2.10051
-3.93-120.246
-2.10051
0.246
0.246
-2.10051
0.246
7.258-29-2.40059

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

345

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

346

63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131

-4.79-120.0
-2.40059
-4.49-120.246
-2.40059
0.246
0.246
-2.40059
0.246
8.204-29-2.70066
-5.39-120.0
-2.70066
-5.06-120.246
-2.70066
0.246
0.246
-2.70066
0.246
8.835-29-3.00073
-5.99-120.0
-3.00073
-5.62-120.246
-3.00073
0.246
0.246
-3.00073
0.246
9.782-29-3.30081
-6.59-120.0
-3.30081
-6.18-120.246
-3.30081
0.246
0.246
-3.30081
0.246
1.073-28-3.60088
-7.19-120.0
-3.60088
-6.74-120.246
-3.60088
0.246
0.246
-3.60088
0.246
1.136-28-3.90095
-7.78-120.0
-3.90095
-7.3-12 0.246
-3.90095
0.246
0.246
-3.90095
0.246
1.231-28-4.20102
-8.38-120.0
-4.20102
-7.86-120.246
-4.20102
0.246
0.246
-4.20102
0.246
1.294-28-4.5011
-8.99-120.0
-4.5011
-8.43-120.246
-4.5011
0.246
0.246
-4.5011
0.246
1.388-28-4.80117
-9.59-120.0
-4.80117
-8.99-120.246
-4.80117
0.246
0.246
-4.80117
0.246
1.452-28-5.10124
-1.02-110.0
-5.10124
-9.55-120.246
-5.10124
0.246
0.246
-5.10124
0.246
1.515-28-5.40132
-1.08-110.0
-5.40132
-1.01-110.246
-5.40132
0.246
0.246
-5.40132
0.246
1.609-28-5.70139
-1.14-110.0
-5.70139
-1.07-110.246
-5.70139
0.246
0.246
-5.70139
0.246
1.672-28-6.00146
-1.2-11 0.0
-6.00146
-1.12-110.246
-6.00146
0.246
0.246
-6.00146
0.246
1.735-28-6.30154
-1.26-110.0
-6.30154
-1.18-110.246
-6.30154
0.246
0.246
-6.30154
0.246
1.83-28 -6.60161
-1.32-110.0
-6.60161
-1.23-110.246
-6.60161
0.246
0.246
-6.60161
0.246
1.893-28-6.90168
-1.38-110.0
-6.90168
-1.29-110.246
-6.90168
0.246
0.246
-6.90168
0.246
1.956-28-7.20176
-1.44-110.0
-7.20176
-1.35-110.246
-7.20176
0.246
0.246
-7.20176
0.246
2.019-28-7.50183
-1.5-11 0.0
-7.50183

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200

Altair Engineering

-1.4-11 0.246
-7.50183
0.246
0.246
-7.50183
0.246
2.083-28-7.8019
-1.55-110.0
-7.8019
-1.46-110.246
-7.8019
0.246
0.246
-7.8019
0.246
2.146-28-8.10198
-1.61-110.0
-8.10198
-1.51-110.246
-8.10198
0.246
0.246
-8.10198
0.246
2.209-28-8.40205
-1.67-110.0
-8.40205
-1.57-110.246
-8.40205
0.246
0.246
-8.40205
0.246
2.272-28-8.70212
-1.73-110.0
-8.70212
-1.63-110.246
-8.70212
0.246
0.246
-8.70212
0.246
2.335-28-9.0022
-1.79-110.0
-9.0022
-1.68-110.246
-9.0022
0.246
0.246
-9.0022
0.246
2.398-28-9.30227
-1.85-110.0
-9.30227
-1.74-110.246
-9.30227
0.246
0.246
-9.30227
0.246
2.461-28-9.60234
-1.91-110.0
-9.60234
-1.79-110.246
-9.60234
0.246
0.246
-9.60234
0.246
2.524-28-9.90241
-1.97-110.0
-9.90241
-1.85-110.246
-9.90241
0.246
0.246
-9.90241
0.246
2.556-28-10.2025
-2.03-110.0
-10.2025
-1.91-110.246
-10.2025
0.246
0.246
-10.2025
0.246
2.619-28-10.5026
-2.09-110.0
-10.5026
-1.96-110.246
-10.5026
0.246
0.246
-10.5026
0.246
2.682-28-10.8026
-2.15-110.0
-10.8026
-2.02-110.246
-10.8026
0.246
0.246
-10.8026
0.246
2.745-28-11.1027
-2.21-110.0
-11.1027
-2.07-110.246
-11.1027
0.246
0.246
-11.1027
0.246
2.777-28-11.4028
-2.27-110.0
-11.4028
-2.13-110.246
-11.4028
0.246
0.246
-11.4028
0.246
2.84-28 -11.7029
-2.33-110.0
-11.7029
-2.19-110.246
-11.7029
0.246
0.246
-11.7029
0.246
2.871-28-12.0029
-2.39-110.0
-12.0029
-2.24-110.246
-12.0029
0.246
0.246
-12.0029
0.246
2.935-28-12.303
-2.45-110.0
-12.303
-2.3-11 0.246
-12.303
0.246
0.246
-12.303
0.246
2.966-28-12.6031
-2.51-110.0
-12.6031
-2.35-110.246
-12.6031

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

347

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

348

201
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589

0.246
0.246
-12.6031
0.246
2.935-28-12.903
-7.36-110.0
-12.903
-6.9-11 0.246
-12.903
0.246
0.246
-12.903
0.246
2.903-28-13.2031
-7.42-110.0
-13.2031
-6.95-110.246
-13.2031
0.246
0.246
-13.2031
0.246
2.84-28 -13.5032
-7.48-110.0
-13.5032
-7.01-110.246
-13.5032
0.246
0.246
-13.5032
0.246
2.777-28-13.8032
-7.54-110.0
-13.8032
-7.06-110.246
-13.8032
0.246
0.246
-13.8032
0.246
2.745-28-14.1033
-7.6-11 0.0
-14.1033
-7.12-110.246
-14.1033
0.246
0.246
-14.1033
0.246
2.682-28-14.4034
-7.67-110.0
-14.4034
-7.19-110.246
-14.4034
0.246
0.246
-14.4034
0.246
2.619-28-14.7034
-7.73-110.0
-14.7034
-7.24-110.246
-14.7034
0.246
0.246
-14.7034
0.246
2.587-28-15.0035
-7.78-110.0
-15.0035
-7.3-11 0.246
-15.0035
0.246
0.246
-15.0035
0.246
2.524-28-15.3036
-7.84-110.0
-15.3036
-7.35-110.246
-15.3036
0.246
0.246
-15.3036
0.246
2.461-28-15.6037
-7.9-11 0.0
-15.6037
-7.41-110.246
-15.6037
0.246
0.246
-15.6037
0.246
2.398-28-15.9037
-7.96-110.0
-15.9037
-7.47-110.246
-15.9037
0.246
0.246
-15.9037
0.246
2.335-28-16.2038
-8.02-110.0
-16.2038
-7.52-110.246
-16.2038
0.246
0.246
-16.2038
0.246
2.272-28-16.5039
-8.08-110.0
-16.5039
-7.58-110.246
-16.5039
0.246
0.246
-16.5039
0.246
2.209-28-16.804
-8.14-110.0
-16.804
-7.63-110.246
-16.804
0.246
0.246
-16.804
0.246
2.146-28-17.104
-8.2-11 0.0
-17.104
-7.69-110.246
-17.104
0.246
0.246
-17.104
0.246
2.083-28-17.4041
-8.26-110.0
-17.4041
-7.75-110.246
-17.4041
0.246
0.246
-17.4041
0.246
2.019-28-17.7042
-8.32-110.0
-17.7042
-7.8-11 0.246
-17.7042
0.246
0.246
-17.7042

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658

Altair Engineering

0.246
1.956-28-18.0042
-8.38-110.0
-18.0042
-7.86-110.246
-18.0042
0.246
0.246
-18.0042
0.246
1.893-28-18.3043
-8.44-110.0
-18.3043
-7.91-110.246
-18.3043
0.246
0.246
-18.3043
0.246
1.83-28 -18.6044
-8.5-11 0.0
-18.6044
-7.97-110.246
-18.6044
0.246
0.246
-18.6044
0.246
1.735-28-18.9045
-8.56-110.0
-18.9045
-8.03-110.246
-18.9045
0.246
0.246
-18.9045
0.246
1.672-28-19.2045
-8.62-110.0
-19.2045
-8.08-110.246
-19.2045
0.246
0.246
-19.2045
0.246
1.609-28-19.5046
-8.68-110.0
-19.5046
-8.14-110.246
-19.5046
0.246
0.246
-19.5046
0.246
1.515-28-19.8047
-8.74-110.0
-19.8047
-8.19-110.246
-19.8047
0.246
0.246
-19.8047
0.246
1.452-28-20.1048
-8.8-11 0.0
-20.1048
-8.25-110.246
-20.1048
0.246
0.246
-20.1048
0.246
1.388-28-20.4048
-8.86-110.0
-20.4048
-8.31-110.246
-20.4048
0.246
0.246
-20.4048
0.246
1.294-28-20.7049
-8.92-110.0
-20.7049
-8.36-110.246
-20.7049
0.246
0.246
-20.7049
0.246
1.231-28-21.005
-8.98-110.0
-21.005
-8.42-110.246
-21.005
0.246
0.246
-21.005
0.246
1.136-28-21.3051
-9.04-110.0
-21.3051
-8.47-110.246
-21.3051
0.246
0.246
-21.3051
0.246
1.073-28-21.6051
-9.1-11 0.0
-21.6051
-8.53-110.246
-21.6051
0.246
0.246
-21.6051
0.246
9.782-29-21.9052
-9.16-110.0
-21.9052
-8.59-110.246
-21.9052
0.246
0.246
-21.9052
0.246
8.835-29-22.2053
-9.22-110.0
-22.2053
-8.64-110.246
-22.2053
0.246
0.246
-22.2053
0.246
8.204-29-22.5053
-9.28-110.0
-22.5053
-8.7-11 0.246
-22.5053
0.246
0.246
-22.5053
0.246
7.258-29-22.8054
-9.34-110.0
-22.8054
-8.75-110.246
-22.8054
0.246
0.246
-22.8054
0.246
6.311-29-23.1055

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

349

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

350

659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727

-9.4-11 0.0
-23.1055
-8.81-110.246
-23.1055
0.246
0.246
-23.1055
0.246
5.364-29-23.4056
-9.46-110.0
-23.4056
-8.87-110.246
-23.4056
0.246
0.246
-23.4056
0.246
4.733-29-23.7056
-9.52-110.0
-23.7056
-8.92-110.246
-23.7056
0.246
0.246
-23.7056
0.246
3.787-29-24.0057
-9.58-110.0
-24.0057
-8.98-110.246
-24.0057
0.246
0.246
-24.0057
0.246
2.84-29 -24.3058
-9.64-110.0
-24.3058
-9.04-110.246
-24.3058
0.246
0.246
-24.3058
0.246
1.893-29-24.6059
-9.7-11 0.0
-24.6059
-9.09-110.246
-24.6059
0.246
0.246
-24.6059
0.246
9.466-30-24.9059
-9.76-110.0
-24.9059
-9.15-110.246
-24.9059
0.246
0.246
-24.9059
0.246
4.151-12-25.206
-9.82-112.767-12-25.206
-9.16-110.246
-25.206
0.246
0.246
-25.206
0.492
4.323-13-.300073
0.492
0.246
-.300073
0.492
1.621-13-.600146
0.492
0.246
-.600146
0.492
1.592-13-0.90022
0.492
0.246
-0.90022
0.492
2.009-13-1.20029
0.492
0.246
-1.20029
0.492
2.5-13 -1.50037
0.492
0.246
-1.50037
0.492
3.004-13-1.80044
0.492
0.246
-1.80044
0.492
3.51-13 -2.10051
0.492
0.246
-2.10051
0.492
4.016-13-2.40059
0.492
0.246
-2.40059
0.492
4.522-13-2.70066
0.492
0.246
-2.70066
0.492
5.028-13-3.00073
0.492
0.246
-3.00073
0.492
5.534-13-3.30081
0.492
0.246
-3.30081
0.492
6.041-13-3.60088
0.492
0.246
-3.60088
0.492
6.547-13-3.90095
0.492
0.246
-3.90095
0.492
7.053-13-4.20102
0.492
0.246
-4.20102
0.492
7.559-13-4.5011
0.492
0.246
-4.5011
0.492
8.066-13-4.80117
0.492
0.246
-4.80117
0.492
8.572-13-5.10124
0.492
0.246
-5.10124
0.492
9.078-13-5.40132
0.492
0.246
-5.40132
0.492
9.584-13-5.70139
0.492
0.246
-5.70139

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956

Altair Engineering

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

1.009-12-6.00146
0.246
-6.00146
1.06-12 -6.30154
0.246
-6.30154
1.11-12 -6.60161
0.246
-6.60161
1.161-12-6.90168
0.246
-6.90168
1.212-12-7.20176
0.246
-7.20176
1.262-12-7.50183
0.246
-7.50183
1.313-12-7.8019
0.246
-7.8019
1.363-12-8.10198
0.246
-8.10198
1.414-12-8.40205
0.246
-8.40205
1.465-12-8.70212
0.246
-8.70212
1.515-12-9.0022
0.246
-9.0022
1.566-12-9.30227
0.246
-9.30227
1.616-12-9.60234
0.246
-9.60234
1.667-12-9.90242
0.246
-9.90242
1.718-12-10.2025
0.246
-10.2025
1.768-12-10.5026
0.246
-10.5026
1.819-12-10.8026
0.246
-10.8026
1.87-12 -11.1027
0.246
-11.1027
1.92-12 -11.4028
0.246
-11.4028
1.971-12-11.7029
0.246
-11.7029
2.021-12-12.0029
0.246
-12.0029
2.072-12-12.303
0.246
-12.303
2.123-12-12.6031
0.246
-12.6031
6.223-12-12.903
0.246
-12.903
6.274-12-13.2031
0.246
-13.2031
6.324-12-13.5032
0.246
-13.5032
6.375-12-13.8032
0.246
-13.8032
6.425-12-14.1033
0.246
-14.1033
6.476-12-14.4034
0.246
-14.4034
6.527-12-14.7034
0.246
-14.7034
6.577-12-15.0035
0.246
-15.0035
6.628-12-15.3036
0.246
-15.3036
6.679-12-15.6037
0.246
-15.6037
6.729-12-15.9037
0.246
-15.9037
6.78-12 -16.2038

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

351

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

352

957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025

0.492
0.246
-16.2038
0.492
6.83-12 -16.5039
0.492
0.246
-16.5039
0.492
6.881-12-16.804
0.492
0.246
-16.804
0.492
6.932-12-17.104
0.492
0.246
-17.104
0.492
6.982-12-17.4041
0.492
0.246
-17.4041
0.492
7.033-12-17.7042
0.492
0.246
-17.7042
0.492
7.083-12-18.0042
0.492
0.246
-18.0042
0.492
7.134-12-18.3043
0.492
0.246
-18.3043
0.492
7.185-12-18.6044
0.492
0.246
-18.6044
0.492
7.235-12-18.9045
0.492
0.246
-18.9045
0.492
7.286-12-19.2045
0.492
0.246
-19.2045
0.492
7.337-12-19.5046
0.492
0.246
-19.5046
0.492
7.387-12-19.8047
0.492
0.246
-19.8047
0.492
7.438-12-20.1048
0.492
0.246
-20.1048
0.492
7.488-12-20.4048
0.492
0.246
-20.4048
0.492
7.539-12-20.7049
0.492
0.246
-20.7049
0.492
7.59-12 -21.005
0.492
0.246
-21.005
0.492
7.64-12 -21.3051
0.492
0.246
-21.3051
0.492
7.691-12-21.6051
0.492
0.246
-21.6051
0.492
7.742-12-21.9052
0.492
0.246
-21.9052
0.492
7.792-12-22.2053
0.492
0.246
-22.2053
0.492
7.843-12-22.5053
0.492
0.246
-22.5053
0.492
7.893-12-22.8054
0.492
0.246
-22.8054
0.492
7.944-12-23.1055
0.492
0.246
-23.1055
0.492
7.995-12-23.4056
0.492
0.246
-23.4056
0.492
8.045-12-23.7056
0.492
0.246
-23.7056
0.492
8.096-12-24.0057
0.492
0.246
-24.0057
0.492
8.146-12-24.3058
0.492
0.246
-24.3058
0.492
8.197-12-24.6059
0.492
0.246
-24.6059
0.492
8.248-12-24.9059
0.492
0.246
-24.9059
0.492
5.534-12-25.206
0.492
0.246
-25.206
-5.24-130.492
-.300073
0.246
0.492
-.300073
-1.05-120.492
-.600146
0.246
0.492
-.600146
-1.57-120.492
-.900219
0.246
0.492
-0.90022
-2.09-120.492
-1.20029
0.246
0.492
-1.20029

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094

Altair Engineering

-2.63-120.492
0.246
0.492
-3.15-120.492
0.246
0.492
-3.67-120.492
0.246
0.492
-4.19-120.492
0.246
0.492
-4.72-120.492
0.246
0.492
-5.24-120.492
0.246
0.492
-5.76-120.492
0.246
0.492
-6.29-120.492
0.246
0.492
-6.81-120.492
0.246
0.492
-7.33-120.492
0.246
0.492
-7.87-120.492
0.246
0.492
-8.39-120.492
0.246
0.492
-8.91-120.492
0.246
0.492
-9.44-120.492
0.246
0.492
-9.96-120.492
0.246
0.492
-1.05-110.492
0.246
0.492
-1.1-11 0.492
0.246
0.492
-1.15-110.492
0.246
0.492
-1.2-11 0.492
0.246
0.492
-1.26-110.492
0.246
0.492
-1.31-110.492
0.246
0.492
-1.36-110.492
0.246
0.492
-1.41-110.492
0.246
0.492
-1.46-110.492
0.246
0.492
-1.52-110.492
0.246
0.492
-1.57-110.492
0.246
0.492
-1.62-110.492
0.246
0.492
-1.67-110.492
0.246
0.492
-1.73-110.492
0.246
0.492
-1.78-110.492
0.246
0.492
-1.83-110.492
0.246
0.492
-1.88-110.492
0.246
0.492
-1.94-110.492
0.246
0.492
-1.99-110.492
0.246
0.492
-2.04-110.492

-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40059
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.30081
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

353

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

354

1095
1096
1097
1098
1099
1100
1101
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323

0.246
0.492
-2.09-110.492
0.246
0.492
-2.14-110.492
0.246
0.492
-2.2-11 0.492
0.246
0.492
-6.43-110.492
0.246
0.492
-6.49-110.492
0.246
0.492
-6.54-110.492
0.246
0.492
-6.59-110.492
0.246
0.492
-6.64-110.492
0.246
0.492
-6.71-110.492
0.246
0.492
-6.76-110.492
0.246
0.492
-6.81-110.492
0.246
0.492
-6.86-110.492
0.246
0.492
-6.91-110.492
0.246
0.492
-6.97-110.492
0.246
0.492
-7.02-110.492
0.246
0.492
-7.07-110.492
0.246
0.492
-7.12-110.492
0.246
0.492
-7.18-110.492
0.246
0.492
-7.23-110.492
0.246
0.492
-7.28-110.492
0.246
0.492
-7.33-110.492
0.246
0.492
-7.39-110.492
0.246
0.492
-7.44-110.492
0.246
0.492
-7.49-110.492
0.246
0.492
-7.54-110.492
0.246
0.492
-7.59-110.492
0.246
0.492
-7.65-110.492
0.246
0.492
-7.7-11 0.492
0.246
0.492
-7.75-110.492
0.246
0.492
-7.8-11 0.492
0.246
0.492
-7.86-110.492
0.246
0.492
-7.91-110.492
0.246
0.492
-7.96-110.492
0.246
0.492
-8.01-110.492
0.246
0.492

-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1468
1469
1470
1471
1472

Altair Engineering

-8.07-110.492
0.246
0.492
-8.12-110.492
0.246
0.492
-8.17-110.492
0.246
0.492
-8.22-110.492
0.246
0.492
-8.27-110.492
0.246
0.492
-8.33-110.492
0.246
0.492
-8.38-110.492
0.246
0.492
-8.43-110.492
0.246
0.492
-8.48-110.492
0.246
0.492
-8.54-110.492
0.246
0.492
-8.59-110.492
0.246
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.600146
-0.90022
-1.20029
-1.50037
-1.80044
-2.10051
-2.40059
-2.70066
-3.00073
-3.30081
-3.60088
-3.90095
-4.20102
-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.0022
-9.30227
-9.60234
-9.90242
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028
-11.7029
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5032
-13.8032
-14.1033

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

355

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

356

1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246

0.492
-14.4034
0.492
-14.7034
0.492
-15.0035
0.492
-15.3036
0.492
-15.6037
0.492
-15.9037
0.492
-16.2038
0.492
-16.5039
0.492
-16.804
0.492
-17.104
0.492
-17.4041
0.492
-17.7042
0.492
-18.0042
0.492
-18.3043
0.492
-18.6044
0.492
-18.9045
0.492
-19.2045
0.492
-19.5046
0.492
-19.8047
0.492
-20.1048
0.492
-20.4048
0.492
-20.7049
0.492
-21.005
0.492
-21.3051
0.492
-21.6051
0.492
-21.9052
0.492
-22.2053
0.492
-22.5053
0.492
-22.8054
0.492
-23.1055
0.492
-23.4056
0.492
-23.7056
0.492
-24.0057
0.492
-24.3058
0.492
-24.6059
0.492
-24.9059
0.492
-25.206
0.0
-.300073
8.522-26-.300073
0.246
-.300073
0.246
-.300073
0.0
-.600146
1.441-26-.600146
0.246
-.600146
0.246
-.600146
0.0
-.900219
2.685-27-.900219
0.246
-.900219
0.246
-.900219
0.0
-1.20029
8.709-28-1.20029
0.246
-1.20029
0.246
-1.20029
0.0
-1.50037
6.595-28-1.50037
0.246
-1.50037
0.246
-1.50037
0.0
-1.80044
7.258-28-1.80044
0.246
-1.80044
0.246
-1.80044
0.0
-2.10051
7.936-28-2.10051
0.246
-2.10051
0.246
-2.10051
0.0
-2.40058
8.993-28-2.40058
0.246
-2.40058
0.246
-2.40058

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610

Altair Engineering

-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246

0.0
-2.70066
1.01-27 -2.70066
0.246
-2.70066
0.246
-2.70066
0.0
-3.00073
1.185-27-3.00073
0.246
-3.00073
0.246
-3.00073
0.0
-3.3008
1.313-27-3.3008
0.246
-3.3008
0.246
-3.3008
0.0
-3.60088
1.341-27-3.60088
0.246
-3.60088
0.246
-3.60088
0.0
-3.90095
1.36-27 -3.90095
0.246
-3.90095
0.246
-3.90095
0.0
-4.20102
1.447-27-4.20102
0.246
-4.20102
0.246
-4.20102
0.0
-4.5011
1.549-27-4.5011
0.246
-4.5011
0.246
-4.5011
0.0
-4.80117
1.775-27-4.80117
0.246
-4.80117
0.246
-4.80117
0.0
-5.10124
1.907-27-5.10124
0.246
-5.10124
0.246
-5.10124
0.0
-5.40132
2.023-27-5.40132
0.246
-5.40132
0.246
-5.40132
0.0
-5.70139
2.136-27-5.70139
0.246
-5.70139
0.246
-5.70139
0.0
-6.00146
2.248-27-6.00146
0.246
-6.00146
0.246
-6.00146
0.0
-6.30154
2.36-27 -6.30154
0.246
-6.30154
0.246
-6.30154
0.0
-6.60161
2.474-27-6.60161
0.246
-6.60161
0.246
-6.60161
0.0
-6.90168
2.551-27-6.90168
0.246
-6.90168
0.246
-6.90168
0.0
-7.20176
2.693-27-7.20176
0.246
-7.20176
0.246
-7.20176
0.0
-7.50183
2.965-27-7.50183
0.246
-7.50183
0.246
-7.50183
0.0
-7.8019

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

357

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

358

1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1998
1999

-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492

3.113-27-7.8019
0.246
-7.8019
0.246
-7.8019
0.0
-8.10198
3.067-27-8.10198
0.246
-8.10198
0.246
-8.10198
0.0
-8.40205
2.979-27-8.40205
0.246
-8.40205
0.246
-8.40205
0.0
-8.70212
3.233-27-8.70212
0.246
-8.70212
0.246
-8.70212
0.0
-9.0022
3.323-27-9.00219
0.246
-9.00219
0.246
-9.0022
0.0
-9.30227
3.67-27 -9.30227
0.246
-9.30227
0.246
-9.30227
0.0
-9.60234
3.58-27 -9.60234
0.246
-9.60234
0.246
-9.60234
0.0
-9.90241
3.454-27-9.90241
0.246
-9.90241
0.246
-9.90241
0.0
-10.2025
3.782-27-10.2025
0.246
-10.2025
0.246
-10.2025
0.0
-10.5026
3.659-27-10.5026
0.246
-10.5026
0.246
-10.5026
0.0
-10.8026
4.003-27-10.8026
0.246
-10.8026
0.246
-10.8026
0.0
-11.1027
4.154-27-11.1027
0.246
-11.1027
0.246
-11.1027
0.0
-11.4028
4.274-27-11.4028
0.246
-11.4028
0.246
-11.4028
0.0
-11.7029
4.388-27-11.7028
0.246
-11.7028
0.246
-11.7029
0.0
-12.0029
4.5-27 -12.0029
0.246
-12.0029
0.246
-12.0029
0.0
-12.303
4.358-27-12.303
0.246
-12.303
0.246
-12.303
0.0
-12.6031
4.424-27-12.6031
0.246
-12.6031
0.246
-12.6031
0.0
-12.903
1.381-26-12.903

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068

Altair Engineering

-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492

0.246
-12.903
0.246
-12.903
0.0
-13.2031
1.395-26-13.2031
0.246
-13.2031
0.246
-13.2031
0.0
-13.5032
1.407-26-13.5031
0.246
-13.5031
0.246
-13.5032
0.0
-13.8032
1.418-26-13.8032
0.246
-13.8032
0.246
-13.8032
0.0
-14.1033
1.429-26-14.1033
0.246
-14.1033
0.246
-14.1033
0.0
-14.4034
1.441-26-14.4034
0.246
-14.4034
0.246
-14.4034
0.0
-14.7034
1.452-26-14.7034
0.246
-14.7034
0.246
-14.7034
0.0
-15.0035
1.463-26-15.0035
0.246
-15.0035
0.246
-15.0035
0.0
-15.3036
1.454-26-15.3036
0.246
-15.3036
0.246
-15.3036
0.0
-15.6037
1.38-26 -15.6037
0.246
-15.6037
0.246
-15.6037
0.0
-15.9037
1.479-26-15.9037
0.246
-15.9037
0.246
-15.9037
0.0
-16.2038
1.505-26-16.2038
0.246
-16.2038
0.246
-16.2038
0.0
-16.5039
1.519-26-16.5039
0.246
-16.5039
0.246
-16.5039
0.0
-16.804
1.531-26-16.804
0.246
-16.804
0.246
-16.804
0.0
-17.104
1.542-26-17.104
0.246
-17.104
0.246
-17.104
0.0
-17.4041
1.553-26-17.4041
0.246
-17.4041
0.246
-17.4041
0.0
-17.7042
1.564-26-17.7042
0.246
-17.7042
0.246
-17.7042
0.0
-18.0042
1.576-26-18.0042
0.246
-18.0042

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

359

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

360

2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137

-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246

0.246
-18.0042
0.0
-18.3043
1.477-26-18.3043
0.246
-18.3043
0.246
-18.3043
0.0
-18.6044
1.58-26 -18.6044
0.246
-18.6044
0.246
-18.6044
0.0
-18.9045
1.606-26-18.9045
0.246
-18.9045
0.246
-18.9045
0.0
-19.2045
1.62-26 -19.2045
0.246
-19.2045
0.246
-19.2045
0.0
-19.5046
1.632-26-19.5046
0.246
-19.5046
0.246
-19.5046
0.0
-19.8047
1.643-26-19.8047
0.246
-19.8047
0.246
-19.8047
0.0
-20.1048
1.655-26-20.1048
0.246
-20.1048
0.246
-20.1048
0.0
-20.4048
1.666-26-20.4048
0.246
-20.4048
0.246
-20.4048
0.0
-20.7049
1.677-26-20.7049
0.246
-20.7049
0.246
-20.7049
0.0
-21.005
1.572-26-21.005
0.246
-21.005
0.246
-21.005
0.0
-21.3051
1.68-26 -21.3051
0.246
-21.3051
0.246
-21.3051
0.0
-21.6051
1.708-26-21.6051
0.246
-21.6051
0.246
-21.6051
0.0
-21.9052
1.722-26-21.9052
0.246
-21.9052
0.246
-21.9052
0.0
-22.2053
1.733-26-22.2053
0.246
-22.2053
0.246
-22.2053
0.0
-22.5053
1.745-26-22.5053
0.246
-22.5053
0.246
-22.5053
0.0
-22.8054
1.756-26-22.8054
0.246
-22.8054
0.246
-22.8054
0.0
-23.1055
1.767-26-23.1055
0.246
-23.1055
0.246
-23.1055

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206

Altair Engineering

-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492

0.0
-23.4056
1.778-26-23.4056
0.246
-23.4056
0.246
-23.4056
0.0
-23.7056
1.666-26-23.7056
0.246
-23.7056
0.246
-23.7056
0.0
-24.0057
1.78-26 -24.0057
0.246
-24.0057
0.246
-24.0057
0.0
-24.3058
1.809-26-24.3058
0.246
-24.3058
0.246
-24.3058
0.0
-24.6059
1.823-26-24.6059
0.246
-24.6059
0.246
-24.6059
0.0
-24.9059
1.835-26-24.9059
0.246
-24.9059
0.246
-24.9059
1.384-12-25.206
1.272-26-25.206
0.246
-25.206
0.246
-25.206
0.492
-.300073
0.492
-.300073
0.492
-.600146
0.492
-.600146
0.492
-.900219
0.492
-.900219
0.492
-1.20029
0.492
-1.20029
0.492
-1.50037
0.492
-1.50037
0.492
-1.80044
0.492
-1.80044
0.492
-2.10051
0.492
-2.10051
0.492
-2.40058
0.492
-2.40058
0.492
-2.70066
0.492
-2.70066
0.492
-3.00073
0.492
-3.00073
0.492
-3.3008
0.492
-3.3008
0.492
-3.60088
0.492
-3.60088
0.492
-3.90095
0.492
-3.90095
0.492
-4.20102
0.492
-4.20102
0.492
-4.5011
0.492
-4.5011
0.492
-4.80117
0.492
-4.80117
0.492
-5.10124
0.492
-5.10124
0.492
-5.40132
0.492
-5.40132
0.492
-5.70139
0.492
-5.70139
0.492
-6.00146
0.492
-6.00146
0.492
-6.30154

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

361

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

362

2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435

-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.00219
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7028
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5031
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504

Altair Engineering

-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.246 -0.246
-5.62-13-0.246
-0.246 -0.246
-1.12-12-0.246
-0.246 -0.246
-1.68-12-0.246
-0.246 -0.246
-2.24-12-0.246
-0.246 -0.246
-2.81-12-0.246
-0.246 -0.246

-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.300073
-.600146
-.600146
-.900219
-.900219
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

363

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

364

2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573

-3.37-12-0.246
-0.246 -0.246
-3.93-12-0.246
-0.246 -0.246
-4.49-12-0.246
-0.246 -0.246
-5.06-12-0.246
-0.246 -0.246
-5.62-12-0.246
-0.246 -0.246
-6.18-12-0.246
-0.246 -0.246
-6.74-12-0.246
-0.246 -0.246
-7.3-12 -0.246
-0.246 -0.246
-7.86-12-0.246
-0.246 -0.246
-8.43-12-0.246
-0.246 -0.246
-8.99-12-0.246
-0.246 -0.246
-9.55-12-0.246
-0.246 -0.246
-1.01-11-0.246
-0.246 -0.246
-1.07-11-0.246
-0.246 -0.246
-1.12-11-0.246
-0.246 -0.246
-1.18-11-0.246
-0.246 -0.246
-1.23-11-0.246
-0.246 -0.246
-1.29-11-0.246
-0.246 -0.246
-1.35-11-0.246
-0.246 -0.246
-1.4-11 -0.246
-0.246 -0.246
-1.46-11-0.246
-0.246 -0.246
-1.51-11-0.246
-0.246 -0.246
-1.57-11-0.246
-0.246 -0.246
-1.63-11-0.246
-0.246 -0.246
-1.68-11-0.246
-0.246 -0.246
-1.74-11-0.246
-0.246 -0.246
-1.79-11-0.246
-0.246 -0.246
-1.85-11-0.246
-0.246 -0.246
-1.91-11-0.246
-0.246 -0.246
-1.96-11-0.246
-0.246 -0.246
-2.02-11-0.246
-0.246 -0.246
-2.07-11-0.246
-0.246 -0.246
-2.13-11-0.246
-0.246 -0.246
-2.19-11-0.246
-0.246 -0.246
-2.24-11-0.246

-1.80044
-2.10051
-2.10051
-2.40058
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.3008
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2574
2575
2576
2577
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802

Altair Engineering

-0.246 -0.246
-2.3-11 -0.246
-0.246 -0.246
-2.35-11-0.246
-0.246 -0.246
-6.9-11 -0.246
-0.246 -0.246
-6.95-11-0.246
-0.246 -0.246
-7.01-11-0.246
-0.246 -0.246
-7.06-11-0.246
-0.246 -0.246
-7.12-11-0.246
-0.246 -0.246
-7.19-11-0.246
-0.246 -0.246
-7.24-11-0.246
-0.246 -0.246
-7.3-11 -0.246
-0.246 -0.246
-7.35-11-0.246
-0.246 -0.246
-7.41-11-0.246
-0.246 -0.246
-7.47-11-0.246
-0.246 -0.246
-7.52-11-0.246
-0.246 -0.246
-7.58-11-0.246
-0.246 -0.246
-7.63-11-0.246
-0.246 -0.246
-7.69-11-0.246
-0.246 -0.246
-7.75-11-0.246
-0.246 -0.246
-7.8-11 -0.246
-0.246 -0.246
-7.86-11-0.246
-0.246 -0.246
-7.91-11-0.246
-0.246 -0.246
-7.97-11-0.246
-0.246 -0.246
-8.03-11-0.246
-0.246 -0.246
-8.08-11-0.246
-0.246 -0.246
-8.14-11-0.246
-0.246 -0.246
-8.19-11-0.246
-0.246 -0.246
-8.25-11-0.246
-0.246 -0.246
-8.31-11-0.246
-0.246 -0.246
-8.36-11-0.246
-0.246 -0.246
-8.42-11-0.246
-0.246 -0.246
-8.47-11-0.246
-0.246 -0.246
-8.53-11-0.246
-0.246 -0.246
-8.59-11-0.246
-0.246 -0.246
-8.64-11-0.246
-0.246 -0.246

-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

365

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

366

2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2944
2945
2946
2947
2948
2949
2950
2951

-8.7-11 -0.246
-0.246 -0.246
-8.75-11-0.246
-0.246 -0.246
-8.81-11-0.246
-0.246 -0.246
-8.87-11-0.246
-0.246 -0.246
-8.92-11-0.246
-0.246 -0.246
-8.98-11-0.246
-0.246 -0.246
-9.04-11-0.246
-0.246 -0.246
-9.09-11-0.246
-0.246 -0.246
-9.15-11-0.246
-0.246 -0.246
-9.16-11-0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246

-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300074
-.600146
-.900219
-1.20029
-1.50037
-1.80044
-2.10051
-2.40058
-2.70066
-3.00073
-3.3008
-3.60088
-3.90095
-4.20102
-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.00219
-9.30227
-9.60234
-9.90241
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028
-11.7028
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5031
-13.8032
-14.1033
-14.4034
-14.7034
-15.0035

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020

Altair Engineering

-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.246 -0.492
-5.24-13-0.492
-0.246 -0.492
-1.05-12-0.492
-0.246 -0.492
-1.57-12-0.492
-0.246 -0.492
-2.09-12-0.492
-0.246 -0.492
-2.63-12-0.492
-0.246 -0.492
-3.15-12-0.492
-0.246 -0.492
-3.67-12-0.492
-0.246 -0.492
-4.19-12-0.492
-0.246 -0.492
-4.72-12-0.492
-0.246 -0.492
-5.24-12-0.492
-0.246 -0.492
-5.76-12-0.492
-0.246 -0.492
-6.29-12-0.492
-0.246 -0.492
-6.81-12-0.492
-0.246 -0.492
-7.33-12-0.492
-0.246 -0.492
-7.87-12-0.492
-0.246 -0.492
-8.39-12-0.492
-0.246 -0.492
-8.91-12-0.492
-0.246 -0.492

-15.3036
-15.6037
-15.9037
-16.2038
-16.5039
-16.804
-17.104
-17.4041
-17.7042
-18.0042
-18.3043
-18.6044
-18.9045
-19.2045
-19.5046
-19.8047
-20.1048
-20.4048
-20.7049
-21.005
-21.3051
-21.6051
-21.9052
-22.2053
-22.5053
-22.8054
-23.1055
-23.4056
-23.7056
-24.0057
-24.3058
-24.6059
-24.9059
-25.206
-.300073
-.300073
-.600146
-.600146
-.900219
-.900219
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40058
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.3008
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

367

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

368

3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249

-9.44-12-0.492
-0.246 -0.492
-9.96-12-0.492
-0.246 -0.492
-1.05-11-0.492
-0.246 -0.492
-1.1-11 -0.492
-0.246 -0.492
-1.15-11-0.492
-0.246 -0.492
-1.2-11 -0.492
-0.246 -0.492
-1.26-11-0.492
-0.246 -0.492
-1.31-11-0.492
-0.246 -0.492
-1.36-11-0.492
-0.246 -0.492
-1.41-11-0.492
-0.246 -0.492
-1.46-11-0.492
-0.246 -0.492
-1.52-11-0.492
-0.246 -0.492
-1.57-11-0.492
-0.246 -0.492
-1.62-11-0.492
-0.246 -0.492
-1.67-11-0.492
-0.246 -0.492
-1.73-11-0.492
-0.246 -0.492
-1.78-11-0.492
-0.246 -0.492
-1.83-11-0.492
-0.246 -0.492
-1.88-11-0.492
-0.246 -0.492
-1.94-11-0.492
-0.246 -0.492
-1.99-11-0.492
-0.246 -0.492
-2.04-11-0.492
-0.246 -0.492
-2.09-11-0.492
-0.246 -0.492
-2.14-11-0.492
-0.246 -0.492
-2.2-11 -0.492
-0.246 -0.492
-6.43-11-0.492
-0.246 -0.492
-6.49-11-0.492
-0.246 -0.492
-6.54-11-0.492
-0.246 -0.492
-6.59-11-0.492
-0.246 -0.492
-6.64-11-0.492
-0.246 -0.492
-6.71-11-0.492
-0.246 -0.492
-6.76-11-0.492
-0.246 -0.492
-6.81-11-0.492
-0.246 -0.492
-6.86-11-0.492
-0.246 -0.492
-6.91-11-0.492

-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318

Altair Engineering

-0.246 -0.492
-6.97-11-0.492
-0.246 -0.492
-7.02-11-0.492
-0.246 -0.492
-7.07-11-0.492
-0.246 -0.492
-7.12-11-0.492
-0.246 -0.492
-7.18-11-0.492
-0.246 -0.492
-7.23-11-0.492
-0.246 -0.492
-7.28-11-0.492
-0.246 -0.492
-7.33-11-0.492
-0.246 -0.492
-7.39-11-0.492
-0.246 -0.492
-7.44-11-0.492
-0.246 -0.492
-7.49-11-0.492
-0.246 -0.492
-7.54-11-0.492
-0.246 -0.492
-7.59-11-0.492
-0.246 -0.492
-7.65-11-0.492
-0.246 -0.492
-7.7-11 -0.492
-0.246 -0.492
-7.75-11-0.492
-0.246 -0.492
-7.8-11 -0.492
-0.246 -0.492
-7.86-11-0.492
-0.246 -0.492
-7.91-11-0.492
-0.246 -0.492
-7.96-11-0.492
-0.246 -0.492
-8.01-11-0.492
-0.246 -0.492
-8.07-11-0.492
-0.246 -0.492
-8.12-11-0.492
-0.246 -0.492
-8.17-11-0.492
-0.246 -0.492
-8.22-11-0.492
-0.246 -0.492
-8.27-11-0.492
-0.246 -0.492
-8.33-11-0.492
-0.246 -0.492
-8.38-11-0.492
-0.246 -0.492
-8.43-11-0.492
-0.246 -0.492
-8.48-11-0.492
-0.246 -0.492
-8.54-11-0.492
-0.246 -0.492
-8.59-11-0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492

-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.600146
-.900219
-1.20029
-1.50037

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

369

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

370

3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-1.80044
-2.10051
-2.40058
-2.70066
-3.00073
-3.3008
-3.60088
-3.90095
-4.20102
-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.00219
-9.30227
-9.60234
-9.90241
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028
-11.7028
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5031
-13.8032
-14.1033
-14.4034
-14.7034
-15.0035
-15.3036
-15.6037
-15.9037
-16.2038
-16.5039
-16.804
-17.104
-17.4041
-17.7042
-18.0042
-18.3043
-18.6044
-18.9045
-19.2045
-19.5046
-19.8047
-20.1048
-20.4048
-20.7049
-21.005
-21.3051
-21.6051
-21.9052
-22.2053

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536

Altair Engineering

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-22.5053
-22.8054
-23.1055
-23.4056
-23.7056
-24.0057
-24.3058
-24.6059
-24.9059
-25.206
-.300073
-.300074
-.600146
-.600146
-0.90022
-0.90022
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40059
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.30081
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

371

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

372

3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765

0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90242
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834

Altair Engineering

0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.300074
-.600146
-.600146
-0.90022
-0.90022
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40059
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.30081
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

373

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

374

3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063

0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90242
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132

Altair Engineering

0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

375

GRID
4133
0.492
-0.492 -25.206
GRID
6776
-0.246 -0.246 8.589-16
GRID
6777
0.246
-0.246 -8.59-16
GRID
6778
0.0
-0.246 0.0
GRID
6779
-0.492 -0.246 1.718-15
GRID
6780
-0.492 -0.492 1.718-15
GRID
6781
-0.246 -0.492 8.589-16
GRID
6782
0.0
-0.492 0.0
GRID
6783
0.246
-0.492 -8.59-16
GRID
6784
0.492
-0.492 -1.72-15
GRID
6785
0.492
-0.246 -1.72-15
GRID
6786
0.246
0.246
-8.59-16
GRID
6787
-0.246 0.246
8.589-16
GRID
6788
0.0
0.246
0.0
GRID
6789
0.492
0.246
-1.72-15
GRID
6790
0.492
0.492
-1.72-15
GRID
6791
0.246
0.492
-8.59-16
GRID
6792
0.0
0.492
0.0
GRID
6793
-0.246 0.492
8.589-16
GRID
6794
-0.492 0.492
1.718-15
GRID
6795
-0.492 0.246
1.718-15
GRID
6796
-0.492 0.0
1.718-15
GRID
6797
-0.246 0.0
8.589-16
GRID
6798
0.0
0.0
0.0
GRID
6799
0.246
0.0
-8.59-16
GRID
6800
0.492
0.0
-1.72-15
$$
$$ SPOINT Data
$$
$
$ CQUAD4 Elements
$
CQUAD4
5627
1
6778
6798
6799
CQUAD4
5629
1
6782
6778
6777
CQUAD4
6116
1
6777
6799
6800
CQUAD4
6122
1
6783
6777
6785
CQUAD4
6125
1
6799
6798
6788
CQUAD4
6520
1
6779
6796
6797
CQUAD4
6521
1
6776
6797
6798
CQUAD4
6523
1
6780
6779
6776
CQUAD4
6528
1
6781
6776
6778
CQUAD4
6954
1
6797
6796
6795
CQUAD4
7220
1
6788
6787
6793
CQUAD4
7647
1
6787
6795
6794
CQUAD4
7652
1
6798
6797
6787
CQUAD4
7945
1
6786
6788
6792
CQUAD4
7948
1
6789
6786
6791
CQUAD4
7955
1
6800
6799
6786
$
$HMMOVE
5
$
5627
5629
6116
6122
6125
$
6528
6954
7220
7647
7652
$
$
$ CHEXA Elements: First Order
$
CHEXA
17
2
10
11
21
+
36
37
CHEXA
18
2
34
35
36
+
40
41
CHEXA
19
2
38
39
40
+
44
45
CHEXA
20
2
42
43
44
+
48
49
CHEXA
21
2
46
47
48
+
52
53
CHEXA
22
2
50
51
52
+
56
57
CHEXA
23
2
54
55
56

376

-1

6777
6783
6785
6784
6786
6776
6778
6781
6782
6787
6792
6793
6788
6791
6790
6789
6520THRU
7945
7948

6521
7955

23

34

35

37

38

39

41

42

43

45

46

47

49

50

51

53

54

55

57

58

59

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

6523

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

60
24
64
25
68
26
72
27
76
28
80
29
84
30
88
31
92
32
96
33
100
34
104
35
108
36
112
37
116
38
120
39
124
40
128
41
132
42
136
43
140
44
144
45
148
46
152
47
156
48
160
49
164
50
168
51
172
52
176
53
180
54
184
55
188
56
192
57
196

Altair Engineering

61
2
65
2
69
2
73
2
77
2
81
2
85
2
89
2
93
2
97
2
101
2
105
2
109
2
113
2
117
2
121
2
125
2
129
2
133
2
137
2
141
2
145
2
149
2
153
2
157
2
161
2
165
2
169
2
173
2
177
2
181
2
185
2
189
2
193
2
197

58

59

60

61

62

63

62

63

64

65

66

67

66

67

68

69

70

71

70

71

72

73

74

75

74

75

76

77

78

79

78

79

80

81

82

83

82

83

84

85

86

87

86

87

88

89

90

91

90

91

92

93

94

95

94

95

96

97

98

99

98

99

100

101

102

103

102

103

104

105

106

107

106

107

108

109

110

111

110

111

112

113

114

115

114

115

116

117

118

119

118

119

120

121

122

123

122

123

124

125

126

127

126

127

128

129

130

131

130

131

132

133

134

135

134

135

136

137

138

139

138

139

140

141

142

143

142

143

144

145

146

147

146

147

148

149

150

151

150

151

152

153

154

155

154

155

156

157

158

159

158

159

160

161

162

163

162

163

164

165

166

167

166

167

168

169

170

171

170

171

172

173

174

175

174

175

176

177

178

179

178

179

180

181

182

183

182

183

184

185

186

187

186

187

188

189

190

191

190

191

192

193

194

195

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

377

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

378

58
200
139
524
140
528
141
532
142
536
143
540
144
544
145
548
146
552
147
556
148
560
149
564
150
568
151
572
152
576
153
580
154
584
155
588
156
592
157
596
158
600
159
604
160
608
161
612
162
616
163
620
164
624
165
628
166
632
167
636
168
640
169
644
170
648
171
652
172

2
201
2
525
2
529
2
533
2
537
2
541
2
545
2
549
2
553
2
557
2
561
2
565
2
569
2
573
2
577
2
581
2
585
2
589
2
593
2
597
2
601
2
605
2
609
2
613
2
617
2
621
2
625
2
629
2
633
2
637
2
641
2
645
2
649
2
653
2

194

195

196

197

198

199

198

199

200

201

522

523

522

523

524

525

526

527

526

527

528

529

530

531

530

531

532

533

534

535

534

535

536

537

538

539

538

539

540

541

542

543

542

543

544

545

546

547

546

547

548

549

550

551

550

551

552

553

554

555

554

555

556

557

558

559

558

559

560

561

562

563

562

563

564

565

566

567

566

567

568

569

570

571

570

571

572

573

574

575

574

575

576

577

578

579

578

579

580

581

582

583

582

583

584

585

586

587

586

587

588

589

590

591

590

591

592

593

594

595

594

595

596

597

598

599

598

599

600

601

602

603

602

603

604

605

606

607

606

607

608

609

610

611

610

611

612

613

614

615

614

615

616

617

618

619

618

619

620

621

622

623

622

623

624

625

626

627

626

627

628

629

630

631

630

631

632

633

634

635

634

635

636

637

638

639

638

639

640

641

642

643

642

643

644

645

646

647

646

647

648

649

650

651

650

651

652

653

654

655

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

656
173
660
174
664
175
668
176
672
177
676
178
680
179
684
180
688
181
37
182
41
183
45
184
49
185
53
186
57
187
61
188
65
189
69
190
73
191
77
192
81
193
85
194
89
195
93
196
97
197
101
198
105
199
109
200
113
201
117
202
121
203
125
204
129
205
133
206
137

Altair Engineering

657
2
661
2
665
2
669
2
673
2
677
2
681
2
685
2
689
2
691
2
693
2
695
2
697
2
699
2
701
2
703
2
705
2
707
2
709
2
711
2
713
2
715
2
717
2
719
2
721
2
723
2
725
2
727
2
729
2
731
2
733
2
735
2
737
2
739
2
741

654

655

656

657

658

659

658

659

660

661

662

663

662

663

664

665

666

667

666

667

668

669

670

671

670

671

672

673

674

675

674

675

676

677

678

679

678

679

680

681

682

683

682

683

684

685

686

687

10

23

20

690

34

690

34

37

691

692

38

692

38

41

693

694

42

694

42

45

695

696

46

696

46

49

697

698

50

698

50

53

699

700

54

700

54

57

701

702

58

702

58

61

703

704

62

704

62

65

705

706

66

706

66

69

707

708

70

708

70

73

709

710

74

710

74

77

711

712

78

712

78

81

713

714

82

714

82

85

715

716

86

716

86

89

717

718

90

718

90

93

719

720

94

720

94

97

721

722

98

722

98

101

723

724

102

724

102

105

725

726

106

726

106

109

727

728

110

728

110

113

729

730

114

730

114

117

731

732

118

732

118

121

733

734

122

734

122

125

735

736

126

736

126

129

737

738

130

738

130

133

739

740

134

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

379

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

380

207
141
208
145
209
149
210
153
211
157
212
161
213
165
214
169
215
173
216
177
217
181
218
185
219
189
220
193
221
197
222
201
303
525
304
529
305
533
306
537
307
541
308
545
309
549
310
553
311
557
312
561
313
565
314
569
315
573
316
577
317
581
318
585
319
589
320
593
321

2
743
2
745
2
747
2
749
2
751
2
753
2
755
2
757
2
759
2
761
2
763
2
765
2
767
2
769
2
771
2
773
2
935
2
937
2
939
2
941
2
943
2
945
2
947
2
949
2
951
2
953
2
955
2
957
2
959
2
961
2
963
2
965
2
967
2
969
2

740

134

137

741

742

138

742

138

141

743

744

142

744

142

145

745

746

146

746

146

149

747

748

150

748

150

153

749

750

154

750

154

157

751

752

158

752

158

161

753

754

162

754

162

165

755

756

166

756

166

169

757

758

170

758

170

173

759

760

174

760

174

177

761

762

178

762

178

181

763

764

182

764

182

185

765

766

186

766

186

189

767

768

190

768

190

193

769

770

194

770

194

197

771

772

198

772

198

201

773

934

522

934

522

525

935

936

526

936

526

529

937

938

530

938

530

533

939

940

534

940

534

537

941

942

538

942

538

541

943

944

542

944

542

545

945

946

546

946

546

549

947

948

550

948

550

553

949

950

554

950

554

557

951

952

558

952

558

561

953

954

562

954

562

565

955

956

566

956

566

569

957

958

570

958

570

573

959

960

574

960

574

577

961

962

578

962

578

581

963

964

582

964

582

585

965

966

586

966

586

589

967

968

590

968

590

593

969

970

594

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

597
322
601
323
605
324
609
325
613
326
617
327
621
328
625
329
629
330
633
331
637
332
641
333
645
334
649
335
653
336
657
337
661
338
665
339
669
340
673
341
677
342
681
343
685
344
689
345
1018
346
1020
347
1022
348
1024
349
1026
350
1028
351
1030
352
1032
353
1034
354
1036
355
1038

Altair Engineering

971
2
973
2
975
2
977
2
979
2
981
2
983
2
985
2
987
2
989
2
991
2
993
2
995
2
997
2
999
2
1001
2
1003
2
1005
2
1007
2
1009
2
1011
2
1013
2
1015
2
1017
2
1019
2
1021
2
1023
2
1025
2
1027
2
1029
2
1031
2
1033
2
1035
2
1037
2
1039

970

594

597

971

972

598

972

598

601

973

974

602

974

602

605

975

976

606

976

606

609

977

978

610

978

610

613

979

980

614

980

614

617

981

982

618

982

618

621

983

984

622

984

622

625

985

986

626

986

626

629

987

988

630

988

630

633

989

990

634

990

634

637

991

992

638

992

638

641

993

994

642

994

642

645

995

996

646

996

646

649

997

998

650

998

650

653

999

1000

654

1000

654

657

1001

1002

658

1002

658

661

1003

1004

662

1004

662

665

1005

1006

666

1006

666

669

1007

1008

670

1008

670

673

1009

1010

674

1010

674

677

1011

1012

678

1012

678

681

1013

1014

682

1014

682

685

1015

1016

686

23

21

17

18

37

36

37

36

1018

1019

41

40

41

40

1020

1021

45

44

45

44

1022

1023

49

48

49

48

1024

1025

53

52

53

52

1026

1027

57

56

57

56

1028

1029

61

60

61

60

1030

1031

65

64

65

64

1032

1033

69

68

69

68

1034

1035

73

72

73

72

1036

1037

77

76

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

381

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

382

356
1040
357
1042
358
1044
359
1046
360
1048
361
1050
362
1052
363
1054
364
1056
365
1058
366
1060
367
1062
368
1064
369
1066
370
1068
371
1070
372
1072
373
1074
374
1076
375
1078
376
1080
377
1082
378
1084
379
1086
380
1088
381
1090
382
1092
383
1094
384
1096
385
1098
386
1100
467
1262
468
1264
469
1266
470

2
1041
2
1043
2
1045
2
1047
2
1049
2
1051
2
1053
2
1055
2
1057
2
1059
2
1061
2
1063
2
1065
2
1067
2
1069
2
1071
2
1073
2
1075
2
1077
2
1079
2
1081
2
1083
2
1085
2
1087
2
1089
2
1091
2
1093
2
1095
2
1097
2
1099
2
1101
2
1263
2
1265
2
1267
2

77

76

1038

1039

81

80

81

80

1040

1041

85

84

85

84

1042

1043

89

88

89

88

1044

1045

93

92

93

92

1046

1047

97

96

97

96

1048

1049

101

100

101

100

1050

1051

105

104

105

104

1052

1053

109

108

109

108

1054

1055

113

112

113

112

1056

1057

117

116

117

116

1058

1059

121

120

121

120

1060

1061

125

124

125

124

1062

1063

129

128

129

128

1064

1065

133

132

133

132

1066

1067

137

136

137

136

1068

1069

141

140

141

140

1070

1071

145

144

145

144

1072

1073

149

148

149

148

1074

1075

153

152

153

152

1076

1077

157

156

157

156

1078

1079

161

160

161

160

1080

1081

165

164

165

164

1082

1083

169

168

169

168

1084

1085

173

172

173

172

1086

1087

177

176

177

176

1088

1089

181

180

181

180

1090

1091

185

184

185

184

1092

1093

189

188

189

188

1094

1095

193

192

193

192

1096

1097

197

196

197

196

1098

1099

201

200

201

200

1100

1101

525

524

525

524

1262

1263

529

528

529

528

1264

1265

533

532

533

532

1266

1267

537

536

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1268
471
1270
472
1272
473
1274
474
1276
475
1278
476
1280
477
1282
478
1284
479
1286
480
1288
481
1290
482
1292
483
1294
484
1296
485
1298
486
1300
487
1302
488
1304
489
1306
490
1308
491
1310
492
1312
493
1314
494
1316
495
1318
496
1320
497
1322
498
1324
499
1326
500
1328
501
1330
502
1332
503
1334
504
1336

Altair Engineering

1269
2
1271
2
1273
2
1275
2
1277
2
1279
2
1281
2
1283
2
1285
2
1287
2
1289
2
1291
2
1293
2
1295
2
1297
2
1299
2
1301
2
1303
2
1305
2
1307
2
1309
2
1311
2
1313
2
1315
2
1317
2
1319
2
1321
2
1323
2
1325
2
1327
2
1329
2
1331
2
1333
2
1335
2
1337

537

536

1268

1269

541

540

541

540

1270

1271

545

544

545

544

1272

1273

549

548

549

548

1274

1275

553

552

553

552

1276

1277

557

556

557

556

1278

1279

561

560

561

560

1280

1281

565

564

565

564

1282

1283

569

568

569

568

1284

1285

573

572

573

572

1286

1287

577

576

577

576

1288

1289

581

580

581

580

1290

1291

585

584

585

584

1292

1293

589

588

589

588

1294

1295

593

592

593

592

1296

1297

597

596

597

596

1298

1299

601

600

601

600

1300

1301

605

604

605

604

1302

1303

609

608

609

608

1304

1305

613

612

613

612

1306

1307

617

616

617

616

1308

1309

621

620

621

620

1310

1311

625

624

625

624

1312

1313

629

628

629

628

1314

1315

633

632

633

632

1316

1317

637

636

637

636

1318

1319

641

640

641

640

1320

1321

645

644

645

644

1322

1323

649

648

649

648

1324

1325

653

652

653

652

1326

1327

657

656

657

656

1328

1329

661

660

661

660

1330

1331

665

664

665

664

1332

1333

669

668

669

668

1334

1335

673

672

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

383

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

384

505
1338
506
1340
507
1342
508
1344
509
1019
510
1021
511
1023
512
1025
513
1027
514
1029
515
1031
516
1033
517
1035
518
1037
519
1039
520
1041
521
1043
522
1045
523
1047
524
1049
525
1051
526
1053
527
1055
528
1057
529
1059
530
1061
531
1063
532
1065
533
1067
534
1069
535
1071
536
1073
537
1075
538
1077
539

2
1339
2
1341
2
1343
2
1345
2
1346
2
1347
2
1348
2
1349
2
1350
2
1351
2
1352
2
1353
2
1354
2
1355
2
1356
2
1357
2
1358
2
1359
2
1360
2
1361
2
1362
2
1363
2
1364
2
1365
2
1366
2
1367
2
1368
2
1369
2
1370
2
1371
2
1372
2
1373
2
1374
2
1375
2

673

672

1336

1337

677

676

677

676

1338

1339

681

680

681

680

1340

1341

685

684

685

684

1342

1343

689

688

20

23

18

19

691

37

691

37

1019

1346

693

41

693

41

1021

1347

695

45

695

45

1023

1348

697

49

697

49

1025

1349

699

53

699

53

1027

1350

701

57

701

57

1029

1351

703

61

703

61

1031

1352

705

65

705

65

1033

1353

707

69

707

69

1035

1354

709

73

709

73

1037

1355

711

77

711

77

1039

1356

713

81

713

81

1041

1357

715

85

715

85

1043

1358

717

89

717

89

1045

1359

719

93

719

93

1047

1360

721

97

721

97

1049

1361

723

101

723

101

1051

1362

725

105

725

105

1053

1363

727

109

727

109

1055

1364

729

113

729

113

1057

1365

731

117

731

117

1059

1366

733

121

733

121

1061

1367

735

125

735

125

1063

1368

737

129

737

129

1065

1369

739

133

739

133

1067

1370

741

137

741

137

1069

1371

743

141

743

141

1071

1372

745

145

745

145

1073

1373

747

149

747

149

1075

1374

749

153

749

153

1077

1375

751

157

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1079
540
1081
541
1083
542
1085
543
1087
544
1089
545
1091
546
1093
547
1095
548
1097
549
1099
550
1101
631
1263
632
1265
633
1267
634
1269
635
1271
636
1273
637
1275
638
1277
639
1279
640
1281
641
1283
642
1285
643
1287
644
1289
645
1291
646
1293
647
1295
648
1297
649
1299
650
1301
651
1303
652
1305
653
1307

Altair Engineering

1376
2
1377
2
1378
2
1379
2
1380
2
1381
2
1382
2
1383
2
1384
2
1385
2
1386
2
1387
2
1468
2
1469
2
1470
2
1471
2
1472
2
1473
2
1474
2
1475
2
1476
2
1477
2
1478
2
1479
2
1480
2
1481
2
1482
2
1483
2
1484
2
1485
2
1486
2
1487
2
1488
2
1489
2
1490

751

157

1079

1376

753

161

753

161

1081

1377

755

165

755

165

1083

1378

757

169

757

169

1085

1379

759

173

759

173

1087

1380

761

177

761

177

1089

1381

763

181

763

181

1091

1382

765

185

765

185

1093

1383

767

189

767

189

1095

1384

769

193

769

193

1097

1385

771

197

771

197

1099

1386

773

201

773

201

1101

1387

935

525

935

525

1263

1468

937

529

937

529

1265

1469

939

533

939

533

1267

1470

941

537

941

537

1269

1471

943

541

943

541

1271

1472

945

545

945

545

1273

1473

947

549

947

549

1275

1474

949

553

949

553

1277

1475

951

557

951

557

1279

1476

953

561

953

561

1281

1477

955

565

955

565

1283

1478

957

569

957

569

1285

1479

959

573

959

573

1287

1480

961

577

961

577

1289

1481

963

581

963

581

1291

1482

965

585

965

585

1293

1483

967

589

967

589

1295

1484

969

593

969

593

1297

1485

971

597

971

597

1299

1486

973

601

973

601

1301

1487

975

605

975

605

1303

1488

977

609

977

609

1305

1489

979

613

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

385

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

386

654
1309
655
1311
656
1313
657
1315
658
1317
659
1319
660
1321
661
1323
662
1325
663
1327
664
1329
665
1331
666
1333
667
1335
668
1337
669
1339
670
1341
671
1343
672
1345
673
1512
674
1516
675
1520
676
1524
677
1528
678
1532
679
1536
680
1540
681
1544
682
1548
683
1552
684
1556
685
1560
686
1564
687
1568
688

2
1491
2
1492
2
1493
2
1494
2
1495
2
1496
2
1497
2
1498
2
1499
2
1500
2
1501
2
1502
2
1503
2
1504
2
1505
2
1506
2
1507
2
1508
2
1509
2
1513
2
1517
2
1521
2
1525
2
1529
2
1533
2
1537
2
1541
2
1545
2
1549
2
1553
2
1557
2
1561
2
1565
2
1569
2

979

613

1307

1490

981

617

981

617

1309

1491

983

621

983

621

1311

1492

985

625

985

625

1313

1493

987

629

987

629

1315

1494

989

633

989

633

1317

1495

991

637

991

637

1319

1496

993

641

993

641

1321

1497

995

645

995

645

1323

1498

997

649

997

649

1325

1499

999

653

999

653

1327

1500

1001

657

1001

657

1329

1501

1003

661

1003

661

1331

1502

1005

665

1005

665

1333

1503

1007

669

1007

669

1335

1504

1009

673

1009

673

1337

1505

1011

677

1011

677

1339

1506

1013

681

1013

681

1341

1507

1015

685

1015

685

1343

1508

1017

689

12

13

14

22

1510

1511

1510

1511

1512

1513

1514

1515

1514

1515

1516

1517

1518

1519

1518

1519

1520

1521

1522

1523

1522

1523

1524

1525

1526

1527

1526

1527

1528

1529

1530

1531

1530

1531

1532

1533

1534

1535

1534

1535

1536

1537

1538

1539

1538

1539

1540

1541

1542

1543

1542

1543

1544

1545

1546

1547

1546

1547

1548

1549

1550

1551

1550

1551

1552

1553

1554

1555

1554

1555

1556

1557

1558

1559

1558

1559

1560

1561

1562

1563

1562

1563

1564

1565

1566

1567

1566

1567

1568

1569

1570

1571

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1572
689
1576
690
1580
691
1584
692
1588
693
1592
694
1596
695
1600
696
1604
697
1608
698
1612
699
1616
700
1620
701
1624
702
1628
703
1632
704
1636
705
1640
706
1644
707
1648
708
1652
709
1656
710
1660
711
1664
712
1668
713
1672
714
1676
795
2000
796
2004
797
2008
798
2012
799
2016
800
2020
801
2024
802
2028

Altair Engineering

1573
2
1577
2
1581
2
1585
2
1589
2
1593
2
1597
2
1601
2
1605
2
1609
2
1613
2
1617
2
1621
2
1625
2
1629
2
1633
2
1637
2
1641
2
1645
2
1649
2
1653
2
1657
2
1661
2
1665
2
1669
2
1673
2
1677
2
2001
2
2005
2
2009
2
2013
2
2017
2
2021
2
2025
2
2029

1570

1571

1572

1573

1574

1575

1574

1575

1576

1577

1578

1579

1578

1579

1580

1581

1582

1583

1582

1583

1584

1585

1586

1587

1586

1587

1588

1589

1590

1591

1590

1591

1592

1593

1594

1595

1594

1595

1596

1597

1598

1599

1598

1599

1600

1601

1602

1603

1602

1603

1604

1605

1606

1607

1606

1607

1608

1609

1610

1611

1610

1611

1612

1613

1614

1615

1614

1615

1616

1617

1618

1619

1618

1619

1620

1621

1622

1623

1622

1623

1624

1625

1626

1627

1626

1627

1628

1629

1630

1631

1630

1631

1632

1633

1634

1635

1634

1635

1636

1637

1638

1639

1638

1639

1640

1641

1642

1643

1642

1643

1644

1645

1646

1647

1646

1647

1648

1649

1650

1651

1650

1651

1652

1653

1654

1655

1654

1655

1656

1657

1658

1659

1658

1659

1660

1661

1662

1663

1662

1663

1664

1665

1666

1667

1666

1667

1668

1669

1670

1671

1670

1671

1672

1673

1674

1675

1674

1675

1676

1677

1998

1999

1998

1999

2000

2001

2002

2003

2002

2003

2004

2005

2006

2007

2006

2007

2008

2009

2010

2011

2010

2011

2012

2013

2014

2015

2014

2015

2016

2017

2018

2019

2018

2019

2020

2021

2022

2023

2022

2023

2024

2025

2026

2027

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

387

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

388

803
2032
804
2036
805
2040
806
2044
807
2048
808
2052
809
2056
810
2060
811
2064
812
2068
813
2072
814
2076
815
2080
816
2084
817
2088
818
2092
819
2096
820
2100
821
2104
822
2108
823
2112
824
2116
825
2120
826
2124
827
2128
828
2132
829
2136
830
2140
831
2144
832
2148
833
2152
834
2156
835
2160
836
2164
837

2
2033
2
2037
2
2041
2
2045
2
2049
2
2053
2
2057
2
2061
2
2065
2
2069
2
2073
2
2077
2
2081
2
2085
2
2089
2
2093
2
2097
2
2101
2
2105
2
2109
2
2113
2
2117
2
2121
2
2125
2
2129
2
2133
2
2137
2
2141
2
2145
2
2149
2
2153
2
2157
2
2161
2
2165
2

2026

2027

2028

2029

2030

2031

2030

2031

2032

2033

2034

2035

2034

2035

2036

2037

2038

2039

2038

2039

2040

2041

2042

2043

2042

2043

2044

2045

2046

2047

2046

2047

2048

2049

2050

2051

2050

2051

2052

2053

2054

2055

2054

2055

2056

2057

2058

2059

2058

2059

2060

2061

2062

2063

2062

2063

2064

2065

2066

2067

2066

2067

2068

2069

2070

2071

2070

2071

2072

2073

2074

2075

2074

2075

2076

2077

2078

2079

2078

2079

2080

2081

2082

2083

2082

2083

2084

2085

2086

2087

2086

2087

2088

2089

2090

2091

2090

2091

2092

2093

2094

2095

2094

2095

2096

2097

2098

2099

2098

2099

2100

2101

2102

2103

2102

2103

2104

2105

2106

2107

2106

2107

2108

2109

2110

2111

2110

2111

2112

2113

2114

2115

2114

2115

2116

2117

2118

2119

2118

2119

2120

2121

2122

2123

2122

2123

2124

2125

2126

2127

2126

2127

2128

2129

2130

2131

2130

2131

2132

2133

2134

2135

2134

2135

2136

2137

2138

2139

2138

2139

2140

2141

2142

2143

2142

2143

2144

2145

2146

2147

2146

2147

2148

2149

2150

2151

2150

2151

2152

2153

2154

2155

2154

2155

2156

2157

2158

2159

2158

2159

2160

2161

2162

2163

11

12

22

21

35

1510

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1513
838
1517
839
1521
840
1525
841
1529
842
1533
843
1537
844
1541
845
1545
846
1549
847
1553
848
1557
849
1561
850
1565
851
1569
852
1573
853
1577
854
1581
855
1585
856
1589
857
1593
858
1597
859
1601
860
1605
861
1609
862
1613
863
1617
864
1621
865
1625
866
1629
867
1633
868
1637
869
1641
870
1645
871
1649

Altair Engineering

36
2
40
2
44
2
48
2
52
2
56
2
60
2
64
2
68
2
72
2
76
2
80
2
84
2
88
2
92
2
96
2
100
2
104
2
108
2
112
2
116
2
120
2
124
2
128
2
132
2
136
2
140
2
144
2
148
2
152
2
156
2
160
2
164
2
168
2
172

35

1510

1513

36

39

1514

39

1514

1517

40

43

1518

43

1518

1521

44

47

1522

47

1522

1525

48

51

1526

51

1526

1529

52

55

1530

55

1530

1533

56

59

1534

59

1534

1537

60

63

1538

63

1538

1541

64

67

1542

67

1542

1545

68

71

1546

71

1546

1549

72

75

1550

75

1550

1553

76

79

1554

79

1554

1557

80

83

1558

83

1558

1561

84

87

1562

87

1562

1565

88

91

1566

91

1566

1569

92

95

1570

95

1570

1573

96

99

1574

99

1574

1577

100

103

1578

103

1578

1581

104

107

1582

107

1582

1585

108

111

1586

111

1586

1589

112

115

1590

115

1590

1593

116

119

1594

119

1594

1597

120

123

1598

123

1598

1601

124

127

1602

127

1602

1605

128

131

1606

131

1606

1609

132

135

1610

135

1610

1613

136

139

1614

139

1614

1617

140

143

1618

143

1618

1621

144

147

1622

147

1622

1625

148

151

1626

151

1626

1629

152

155

1630

155

1630

1633

156

159

1634

159

1634

1637

160

163

1638

163

1638

1641

164

167

1642

167

1642

1645

168

171

1646

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

389

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

390

872
1653
873
1657
874
1661
875
1665
876
1669
877
1673
878
1677
959
2001
960
2005
961
2009
962
2013
963
2017
964
2021
965
2025
966
2029
967
2033
968
2037
969
2041
970
2045
971
2049
972
2053
973
2057
974
2061
975
2065
976
2069
977
2073
978
2077
979
2081
980
2085
981
2089
982
2093
983
2097
984
2101
985
2105
986

2
176
2
180
2
184
2
188
2
192
2
196
2
200
2
524
2
528
2
532
2
536
2
540
2
544
2
548
2
552
2
556
2
560
2
564
2
568
2
572
2
576
2
580
2
584
2
588
2
592
2
596
2
600
2
604
2
608
2
612
2
616
2
620
2
624
2
628
2

171

1646

1649

172

175

1650

175

1650

1653

176

179

1654

179

1654

1657

180

183

1658

183

1658

1661

184

187

1662

187

1662

1665

188

191

1666

191

1666

1669

192

195

1670

195

1670

1673

196

199

1674

199

1674

1677

200

523

1998

523

1998

2001

524

527

2002

527

2002

2005

528

531

2006

531

2006

2009

532

535

2010

535

2010

2013

536

539

2014

539

2014

2017

540

543

2018

543

2018

2021

544

547

2022

547

2022

2025

548

551

2026

551

2026

2029

552

555

2030

555

2030

2033

556

559

2034

559

2034

2037

560

563

2038

563

2038

2041

564

567

2042

567

2042

2045

568

571

2046

571

2046

2049

572

575

2050

575

2050

2053

576

579

2054

579

2054

2057

580

583

2058

583

2058

2061

584

587

2062

587

2062

2065

588

591

2066

591

2066

2069

592

595

2070

595

2070

2073

596

599

2074

599

2074

2077

600

603

2078

603

2078

2081

604

607

2082

607

2082

2085

608

611

2086

611

2086

2089

612

615

2090

615

2090

2093

616

619

2094

619

2094

2097

620

623

2098

623

2098

2101

624

627

2102

627

2102

2105

628

631

2106

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2109
987
2113
988
2117
989
2121
990
2125
991
2129
992
2133
993
2137
994
2141
995
2145
996
2149
997
2153
998
2157
999
2161
1000
2165
1001
2166
1002
2168
1003
2170
1004
2172
1005
2174
1006
2176
1007
2178
1008
2180
1009
2182
1010
2184
1011
2186
1012
2188
1013
2190
1014
2192
1015
2194
1016
2196
1017
2198
1018
2200
1019
2202
1020
2204

Altair Engineering

632
2
636
2
640
2
644
2
648
2
652
2
656
2
660
2
664
2
668
2
672
2
676
2
680
2
684
2
688
2
2167
2
2169
2
2171
2
2173
2
2175
2
2177
2
2179
2
2181
2
2183
2
2185
2
2187
2
2189
2
2191
2
2193
2
2195
2
2197
2
2199
2
2201
2
2203
2
2205

631

2106

2109

632

635

2110

635

2110

2113

636

639

2114

639

2114

2117

640

643

2118

643

2118

2121

644

647

2122

647

2122

2125

648

651

2126

651

2126

2129

652

655

2130

655

2130

2133

656

659

2134

659

2134

2137

660

663

2138

663

2138

2141

664

667

2142

667

2142

2145

668

671

2146

671

2146

2149

672

675

2150

675

2150

2153

676

679

2154

679

2154

2157

680

683

2158

683

2158

2161

684

687

2162

22

14

15

16

1513

1512

1513

1512

2166

2167

1517

1516

1517

1516

2168

2169

1521

1520

1521

1520

2170

2171

1525

1524

1525

1524

2172

2173

1529

1528

1529

1528

2174

2175

1533

1532

1533

1532

2176

2177

1537

1536

1537

1536

2178

2179

1541

1540

1541

1540

2180

2181

1545

1544

1545

1544

2182

2183

1549

1548

1549

1548

2184

2185

1553

1552

1553

1552

2186

2187

1557

1556

1557

1556

2188

2189

1561

1560

1561

1560

2190

2191

1565

1564

1565

1564

2192

2193

1569

1568

1569

1568

2194

2195

1573

1572

1573

1572

2196

2197

1577

1576

1577

1576

2198

2199

1581

1580

1581

1580

2200

2201

1585

1584

1585

1584

2202

2203

1589

1588

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

391

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

392

1021
2206
1022
2208
1023
2210
1024
2212
1025
2214
1026
2216
1027
2218
1028
2220
1029
2222
1030
2224
1031
2226
1032
2228
1033
2230
1034
2232
1035
2234
1036
2236
1037
2238
1038
2240
1039
2242
1040
2244
1041
2246
1042
2248
1123
2410
1124
2412
1125
2414
1126
2416
1127
2418
1128
2420
1129
2422
1130
2424
1131
2426
1132
2428
1133
2430
1134
2432
1135

2
2207
2
2209
2
2211
2
2213
2
2215
2
2217
2
2219
2
2221
2
2223
2
2225
2
2227
2
2229
2
2231
2
2233
2
2235
2
2237
2
2239
2
2241
2
2243
2
2245
2
2247
2
2249
2
2411
2
2413
2
2415
2
2417
2
2419
2
2421
2
2423
2
2425
2
2427
2
2429
2
2431
2
2433
2

1589

1588

2204

2205

1593

1592

1593

1592

2206

2207

1597

1596

1597

1596

2208

2209

1601

1600

1601

1600

2210

2211

1605

1604

1605

1604

2212

2213

1609

1608

1609

1608

2214

2215

1613

1612

1613

1612

2216

2217

1617

1616

1617

1616

2218

2219

1621

1620

1621

1620

2220

2221

1625

1624

1625

1624

2222

2223

1629

1628

1629

1628

2224

2225

1633

1632

1633

1632

2226

2227

1637

1636

1637

1636

2228

2229

1641

1640

1641

1640

2230

2231

1645

1644

1645

1644

2232

2233

1649

1648

1649

1648

2234

2235

1653

1652

1653

1652

2236

2237

1657

1656

1657

1656

2238

2239

1661

1660

1661

1660

2240

2241

1665

1664

1665

1664

2242

2243

1669

1668

1669

1668

2244

2245

1673

1672

1673

1672

2246

2247

1677

1676

1677

1676

2248

2249

2001

2000

2001

2000

2410

2411

2005

2004

2005

2004

2412

2413

2009

2008

2009

2008

2414

2415

2013

2012

2013

2012

2416

2417

2017

2016

2017

2016

2418

2419

2021

2020

2021

2020

2420

2421

2025

2024

2025

2024

2422

2423

2029

2028

2029

2028

2424

2425

2033

2032

2033

2032

2426

2427

2037

2036

2037

2036

2428

2429

2041

2040

2041

2040

2430

2431

2045

2044

2045

2044

2432

2433

2049

2048

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2434
1136
2436
1137
2438
1138
2440
1139
2442
1140
2444
1141
2446
1142
2448
1143
2450
1144
2452
1145
2454
1146
2456
1147
2458
1148
2460
1149
2462
1150
2464
1151
2466
1152
2468
1153
2470
1154
2472
1155
2474
1156
2476
1157
2478
1158
2480
1159
2482
1160
2484
1161
2486
1162
2488
1163
2490
1164
2492
1165
2167
1166
2169
1167
2171
1168
2173
1169
2175

Altair Engineering

2435
2
2437
2
2439
2
2441
2
2443
2
2445
2
2447
2
2449
2
2451
2
2453
2
2455
2
2457
2
2459
2
2461
2
2463
2
2465
2
2467
2
2469
2
2471
2
2473
2
2475
2
2477
2
2479
2
2481
2
2483
2
2485
2
2487
2
2489
2
2491
2
2493
2
1018
2
1020
2
1022
2
1024
2
1026

2049

2048

2434

2435

2053

2052

2053

2052

2436

2437

2057

2056

2057

2056

2438

2439

2061

2060

2061

2060

2440

2441

2065

2064

2065

2064

2442

2443

2069

2068

2069

2068

2444

2445

2073

2072

2073

2072

2446

2447

2077

2076

2077

2076

2448

2449

2081

2080

2081

2080

2450

2451

2085

2084

2085

2084

2452

2453

2089

2088

2089

2088

2454

2455

2093

2092

2093

2092

2456

2457

2097

2096

2097

2096

2458

2459

2101

2100

2101

2100

2460

2461

2105

2104

2105

2104

2462

2463

2109

2108

2109

2108

2464

2465

2113

2112

2113

2112

2466

2467

2117

2116

2117

2116

2468

2469

2121

2120

2121

2120

2470

2471

2125

2124

2125

2124

2472

2473

2129

2128

2129

2128

2474

2475

2133

2132

2133

2132

2476

2477

2137

2136

2137

2136

2478

2479

2141

2140

2141

2140

2480

2481

2145

2144

2145

2144

2482

2483

2149

2148

2149

2148

2484

2485

2153

2152

2153

2152

2486

2487

2157

2156

2157

2156

2488

2489

2161

2160

2161

2160

2490

2491

2165

2164

21

22

16

17

36

1513

36

1513

2167

1018

40

1517

40

1517

2169

1020

44

1521

44

1521

2171

1022

48

1525

48

1525

2173

1024

52

1529

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

393

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

394

1170
2177
1171
2179
1172
2181
1173
2183
1174
2185
1175
2187
1176
2189
1177
2191
1178
2193
1179
2195
1180
2197
1181
2199
1182
2201
1183
2203
1184
2205
1185
2207
1186
2209
1187
2211
1188
2213
1189
2215
1190
2217
1191
2219
1192
2221
1193
2223
1194
2225
1195
2227
1196
2229
1197
2231
1198
2233
1199
2235
1200
2237
1201
2239
1202
2241
1203
2243
1204

2
1028
2
1030
2
1032
2
1034
2
1036
2
1038
2
1040
2
1042
2
1044
2
1046
2
1048
2
1050
2
1052
2
1054
2
1056
2
1058
2
1060
2
1062
2
1064
2
1066
2
1068
2
1070
2
1072
2
1074
2
1076
2
1078
2
1080
2
1082
2
1084
2
1086
2
1088
2
1090
2
1092
2
1094
2

52

1529

2175

1026

56

1533

56

1533

2177

1028

60

1537

60

1537

2179

1030

64

1541

64

1541

2181

1032

68

1545

68

1545

2183

1034

72

1549

72

1549

2185

1036

76

1553

76

1553

2187

1038

80

1557

80

1557

2189

1040

84

1561

84

1561

2191

1042

88

1565

88

1565

2193

1044

92

1569

92

1569

2195

1046

96

1573

96

1573

2197

1048

100

1577

100

1577

2199

1050

104

1581

104

1581

2201

1052

108

1585

108

1585

2203

1054

112

1589

112

1589

2205

1056

116

1593

116

1593

2207

1058

120

1597

120

1597

2209

1060

124

1601

124

1601

2211

1062

128

1605

128

1605

2213

1064

132

1609

132

1609

2215

1066

136

1613

136

1613

2217

1068

140

1617

140

1617

2219

1070

144

1621

144

1621

2221

1072

148

1625

148

1625

2223

1074

152

1629

152

1629

2225

1076

156

1633

156

1633

2227

1078

160

1637

160

1637

2229

1080

164

1641

164

1641

2231

1082

168

1645

168

1645

2233

1084

172

1649

172

1649

2235

1086

176

1653

176

1653

2237

1088

180

1657

180

1657

2239

1090

184

1661

184

1661

2241

1092

188

1665

188

1665

2243

1094

192

1669

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2245
1205
2247
1206
2249
1287
2411
1288
2413
1289
2415
1290
2417
1291
2419
1292
2421
1293
2423
1294
2425
1295
2427
1296
2429
1297
2431
1298
2433
1299
2435
1300
2437
1301
2439
1302
2441
1303
2443
1304
2445
1305
2447
1306
2449
1307
2451
1308
2453
1309
2455
1310
2457
1311
2459
1312
2461
1313
2463
1314
2465
1315
2467
1316
2469
1317
2471
1318
2473

Altair Engineering

1096
2
1098
2
1100
2
1262
2
1264
2
1266
2
1268
2
1270
2
1272
2
1274
2
1276
2
1278
2
1280
2
1282
2
1284
2
1286
2
1288
2
1290
2
1292
2
1294
2
1296
2
1298
2
1300
2
1302
2
1304
2
1306
2
1308
2
1310
2
1312
2
1314
2
1316
2
1318
2
1320
2
1322
2
1324

192

1669

2245

1096

196

1673

196

1673

2247

1098

200

1677

200

1677

2249

1100

524

2001

524

2001

2411

1262

528

2005

528

2005

2413

1264

532

2009

532

2009

2415

1266

536

2013

536

2013

2417

1268

540

2017

540

2017

2419

1270

544

2021

544

2021

2421

1272

548

2025

548

2025

2423

1274

552

2029

552

2029

2425

1276

556

2033

556

2033

2427

1278

560

2037

560

2037

2429

1280

564

2041

564

2041

2431

1282

568

2045

568

2045

2433

1284

572

2049

572

2049

2435

1286

576

2053

576

2053

2437

1288

580

2057

580

2057

2439

1290

584

2061

584

2061

2441

1292

588

2065

588

2065

2443

1294

592

2069

592

2069

2445

1296

596

2073

596

2073

2447

1298

600

2077

600

2077

2449

1300

604

2081

604

2081

2451

1302

608

2085

608

2085

2453

1304

612

2089

612

2089

2455

1306

616

2093

616

2093

2457

1308

620

2097

620

2097

2459

1310

624

2101

624

2101

2461

1312

628

2105

628

2105

2463

1314

632

2109

632

2109

2465

1316

636

2113

636

2113

2467

1318

640

2117

640

2117

2469

1320

644

2121

644

2121

2471

1322

648

2125

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

395

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

396

1319
2475
1320
2477
1321
2479
1322
2481
1323
2483
1324
2485
1325
2487
1326
2489
1327
2491
1328
2493
1329
35
1330
39
1331
43
1332
47
1333
51
1334
55
1335
59
1336
63
1337
67
1338
71
1339
75
1340
79
1341
83
1342
87
1343
91
1344
95
1345
99
1346
103
1347
107
1348
111
1349
115
1350
119
1351
123
1352
127
1353

2
1326
2
1328
2
1330
2
1332
2
1334
2
1336
2
1338
2
1340
2
1342
2
1344
2
2495
2
2497
2
2499
2
2501
2
2503
2
2505
2
2507
2
2509
2
2511
2
2513
2
2515
2
2517
2
2519
2
2521
2
2523
2
2525
2
2527
2
2529
2
2531
2
2533
2
2535
2
2537
2
2539
2
2541
2

648

2125

2473

1324

652

2129

652

2129

2475

1326

656

2133

656

2133

2477

1328

660

2137

660

2137

2479

1330

664

2141

664

2141

2481

1332

668

2145

668

2145

2483

1334

672

2149

672

2149

2485

1336

676

2153

676

2153

2487

1338

680

2157

680

2157

2489

1340

684

2161

684

2161

2491

1342

688

2165

33

12

11

31

2494

1510

2494

1510

35

2495

2496

1514

2496

1514

39

2497

2498

1518

2498

1518

43

2499

2500

1522

2500

1522

47

2501

2502

1526

2502

1526

51

2503

2504

1530

2504

1530

55

2505

2506

1534

2506

1534

59

2507

2508

1538

2508

1538

63

2509

2510

1542

2510

1542

67

2511

2512

1546

2512

1546

71

2513

2514

1550

2514

1550

75

2515

2516

1554

2516

1554

79

2517

2518

1558

2518

1558

83

2519

2520

1562

2520

1562

87

2521

2522

1566

2522

1566

91

2523

2524

1570

2524

1570

95

2525

2526

1574

2526

1574

99

2527

2528

1578

2528

1578

103

2529

2530

1582

2530

1582

107

2531

2532

1586

2532

1586

111

2533

2534

1590

2534

1590

115

2535

2536

1594

2536

1594

119

2537

2538

1598

2538

1598

123

2539

2540

1602

2540

1602

127

2541

2542

1606

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

131
1354
135
1355
139
1356
143
1357
147
1358
151
1359
155
1360
159
1361
163
1362
167
1363
171
1364
175
1365
179
1366
183
1367
187
1368
191
1369
195
1370
199
1451
523
1452
527
1453
531
1454
535
1455
539
1456
543
1457
547
1458
551
1459
555
1460
559
1461
563
1462
567
1463
571
1464
575
1465
579
1466
583
1467
587

Altair Engineering

2543
2
2545
2
2547
2
2549
2
2551
2
2553
2
2555
2
2557
2
2559
2
2561
2
2563
2
2565
2
2567
2
2569
2
2571
2
2573
2
2575
2
2577
2
2739
2
2741
2
2743
2
2745
2
2747
2
2749
2
2751
2
2753
2
2755
2
2757
2
2759
2
2761
2
2763
2
2765
2
2767
2
2769
2
2771

2542

1606

131

2543

2544

1610

2544

1610

135

2545

2546

1614

2546

1614

139

2547

2548

1618

2548

1618

143

2549

2550

1622

2550

1622

147

2551

2552

1626

2552

1626

151

2553

2554

1630

2554

1630

155

2555

2556

1634

2556

1634

159

2557

2558

1638

2558

1638

163

2559

2560

1642

2560

1642

167

2561

2562

1646

2562

1646

171

2563

2564

1650

2564

1650

175

2565

2566

1654

2566

1654

179

2567

2568

1658

2568

1658

183

2569

2570

1662

2570

1662

187

2571

2572

1666

2572

1666

191

2573

2574

1670

2574

1670

195

2575

2576

1674

2576

1674

199

2577

2738

1998

2738

1998

523

2739

2740

2002

2740

2002

527

2741

2742

2006

2742

2006

531

2743

2744

2010

2744

2010

535

2745

2746

2014

2746

2014

539

2747

2748

2018

2748

2018

543

2749

2750

2022

2750

2022

547

2751

2752

2026

2752

2026

551

2753

2754

2030

2754

2030

555

2755

2756

2034

2756

2034

559

2757

2758

2038

2758

2038

563

2759

2760

2042

2760

2042

567

2761

2762

2046

2762

2046

571

2763

2764

2050

2764

2050

575

2765

2766

2054

2766

2054

579

2767

2768

2058

2768

2058

583

2769

2770

2062

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

397

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

398

1468
591
1469
595
1470
599
1471
603
1472
607
1473
611
1474
615
1475
619
1476
623
1477
627
1478
631
1479
635
1480
639
1481
643
1482
647
1483
651
1484
655
1485
659
1486
663
1487
667
1488
671
1489
675
1490
679
1491
683
1492
687
1493
1510
1494
1514
1495
1518
1496
1522
1497
1526
1498
1530
1499
1534
1500
1538
1501
1542
1502

2
2773
2
2775
2
2777
2
2779
2
2781
2
2783
2
2785
2
2787
2
2789
2
2791
2
2793
2
2795
2
2797
2
2799
2
2801
2
2803
2
2805
2
2807
2
2809
2
2811
2
2813
2
2815
2
2817
2
2819
2
2821
2
2494
2
2496
2
2498
2
2500
2
2502
2
2504
2
2506
2
2508
2
2510
2

2770

2062

587

2771

2772

2066

2772

2066

591

2773

2774

2070

2774

2070

595

2775

2776

2074

2776

2074

599

2777

2778

2078

2778

2078

603

2779

2780

2082

2780

2082

607

2781

2782

2086

2782

2086

611

2783

2784

2090

2784

2090

615

2785

2786

2094

2786

2094

619

2787

2788

2098

2788

2098

623

2789

2790

2102

2790

2102

627

2791

2792

2106

2792

2106

631

2793

2794

2110

2794

2110

635

2795

2796

2114

2796

2114

639

2797

2798

2118

2798

2118

643

2799

2800

2122

2800

2122

647

2801

2802

2126

2802

2126

651

2803

2804

2130

2804

2130

655

2805

2806

2134

2806

2134

659

2807

2808

2138

2808

2138

663

2809

2810

2142

2810

2142

667

2811

2812

2146

2812

2146

671

2813

2814

2150

2814

2150

675

2815

2816

2154

2816

2154

679

2817

2818

2158

2818

2158

683

2819

2820

2162

30

13

12

33

2822

1511

2822

1511

1510

2494

2823

1515

2823

1515

1514

2496

2824

1519

2824

1519

1518

2498

2825

1523

2825

1523

1522

2500

2826

1527

2826

1527

1526

2502

2827

1531

2827

1531

1530

2504

2828

1535

2828

1535

1534

2506

2829

1539

2829

1539

1538

2508

2830

1543

2830

1543

1542

2510

2831

1547

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1546
1503
1550
1504
1554
1505
1558
1506
1562
1507
1566
1508
1570
1509
1574
1510
1578
1511
1582
1512
1586
1513
1590
1514
1594
1515
1598
1516
1602
1517
1606
1518
1610
1519
1614
1520
1618
1521
1622
1522
1626
1523
1630
1524
1634
1525
1638
1526
1642
1527
1646
1528
1650
1529
1654
1530
1658
1531
1662
1532
1666
1533
1670
1534
1674
1615
1998
1616
2002

Altair Engineering

2512
2
2514
2
2516
2
2518
2
2520
2
2522
2
2524
2
2526
2
2528
2
2530
2
2532
2
2534
2
2536
2
2538
2
2540
2
2542
2
2544
2
2546
2
2548
2
2550
2
2552
2
2554
2
2556
2
2558
2
2560
2
2562
2
2564
2
2566
2
2568
2
2570
2
2572
2
2574
2
2576
2
2738
2
2740

2831

1547

1546

2512

2832

1551

2832

1551

1550

2514

2833

1555

2833

1555

1554

2516

2834

1559

2834

1559

1558

2518

2835

1563

2835

1563

1562

2520

2836

1567

2836

1567

1566

2522

2837

1571

2837

1571

1570

2524

2838

1575

2838

1575

1574

2526

2839

1579

2839

1579

1578

2528

2840

1583

2840

1583

1582

2530

2841

1587

2841

1587

1586

2532

2842

1591

2842

1591

1590

2534

2843

1595

2843

1595

1594

2536

2844

1599

2844

1599

1598

2538

2845

1603

2845

1603

1602

2540

2846

1607

2846

1607

1606

2542

2847

1611

2847

1611

1610

2544

2848

1615

2848

1615

1614

2546

2849

1619

2849

1619

1618

2548

2850

1623

2850

1623

1622

2550

2851

1627

2851

1627

1626

2552

2852

1631

2852

1631

1630

2554

2853

1635

2853

1635

1634

2556

2854

1639

2854

1639

1638

2558

2855

1643

2855

1643

1642

2560

2856

1647

2856

1647

1646

2562

2857

1651

2857

1651

1650

2564

2858

1655

2858

1655

1654

2566

2859

1659

2859

1659

1658

2568

2860

1663

2860

1663

1662

2570

2861

1667

2861

1667

1666

2572

2862

1671

2862

1671

1670

2574

2863

1675

2863

1675

1674

2576

2944

1999

2944

1999

1998

2738

2945

2003

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

399

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

400

1617
2006
1618
2010
1619
2014
1620
2018
1621
2022
1622
2026
1623
2030
1624
2034
1625
2038
1626
2042
1627
2046
1628
2050
1629
2054
1630
2058
1631
2062
1632
2066
1633
2070
1634
2074
1635
2078
1636
2082
1637
2086
1638
2090
1639
2094
1640
2098
1641
2102
1642
2106
1643
2110
1644
2114
1645
2118
1646
2122
1647
2126
1648
2130
1649
2134
1650
2138
1651

2
2742
2
2744
2
2746
2
2748
2
2750
2
2752
2
2754
2
2756
2
2758
2
2760
2
2762
2
2764
2
2766
2
2768
2
2770
2
2772
2
2774
2
2776
2
2778
2
2780
2
2782
2
2784
2
2786
2
2788
2
2790
2
2792
2
2794
2
2796
2
2798
2
2800
2
2802
2
2804
2
2806
2
2808
2

2945

2003

2002

2740

2946

2007

2946

2007

2006

2742

2947

2011

2947

2011

2010

2744

2948

2015

2948

2015

2014

2746

2949

2019

2949

2019

2018

2748

2950

2023

2950

2023

2022

2750

2951

2027

2951

2027

2026

2752

2952

2031

2952

2031

2030

2754

2953

2035

2953

2035

2034

2756

2954

2039

2954

2039

2038

2758

2955

2043

2955

2043

2042

2760

2956

2047

2956

2047

2046

2762

2957

2051

2957

2051

2050

2764

2958

2055

2958

2055

2054

2766

2959

2059

2959

2059

2058

2768

2960

2063

2960

2063

2062

2770

2961

2067

2961

2067

2066

2772

2962

2071

2962

2071

2070

2774

2963

2075

2963

2075

2074

2776

2964

2079

2964

2079

2078

2778

2965

2083

2965

2083

2082

2780

2966

2087

2966

2087

2086

2782

2967

2091

2967

2091

2090

2784

2968

2095

2968

2095

2094

2786

2969

2099

2969

2099

2098

2788

2970

2103

2970

2103

2102

2790

2971

2107

2971

2107

2106

2792

2972

2111

2972

2111

2110

2794

2973

2115

2973

2115

2114

2796

2974

2119

2974

2119

2118

2798

2975

2123

2975

2123

2122

2800

2976

2127

2976

2127

2126

2802

2977

2131

2977

2131

2130

2804

2978

2135

2978

2135

2134

2806

2979

2139

2979

2139

2138

2808

2980

2143

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2142
1652
2146
1653
2150
1654
2154
1655
2158
1656
2162
1657
2495
1658
2497
1659
2499
1660
2501
1661
2503
1662
2505
1663
2507
1664
2509
1665
2511
1666
2513
1667
2515
1668
2517
1669
2519
1670
2521
1671
2523
1672
2525
1673
2527
1674
2529
1675
2531
1676
2533
1677
2535
1678
2537
1679
2539
1680
2541
1681
2543
1682
2545
1683
2547
1684
2549
1685
2551

Altair Engineering

2810
2
2812
2
2814
2
2816
2
2818
2
2820
2
2987
2
2989
2
2991
2
2993
2
2995
2
2997
2
2999
2
3001
2
3003
2
3005
2
3007
2
3009
2
3011
2
3013
2
3015
2
3017
2
3019
2
3021
2
3023
2
3025
2
3027
2
3029
2
3031
2
3033
2
3035
2
3037
2
3039
2
3041
2
3043

2980

2143

2142

2810

2981

2147

2981

2147

2146

2812

2982

2151

2982

2151

2150

2814

2983

2155

2983

2155

2154

2816

2984

2159

2984

2159

2158

2818

2985

2163

28

33

31

27

2986

2494

2986

2494

2495

2987

2988

2496

2988

2496

2497

2989

2990

2498

2990

2498

2499

2991

2992

2500

2992

2500

2501

2993

2994

2502

2994

2502

2503

2995

2996

2504

2996

2504

2505

2997

2998

2506

2998

2506

2507

2999

3000

2508

3000

2508

2509

3001

3002

2510

3002

2510

2511

3003

3004

2512

3004

2512

2513

3005

3006

2514

3006

2514

2515

3007

3008

2516

3008

2516

2517

3009

3010

2518

3010

2518

2519

3011

3012

2520

3012

2520

2521

3013

3014

2522

3014

2522

2523

3015

3016

2524

3016

2524

2525

3017

3018

2526

3018

2526

2527

3019

3020

2528

3020

2528

2529

3021

3022

2530

3022

2530

2531

3023

3024

2532

3024

2532

2533

3025

3026

2534

3026

2534

2535

3027

3028

2536

3028

2536

2537

3029

3030

2538

3030

2538

2539

3031

3032

2540

3032

2540

2541

3033

3034

2542

3034

2542

2543

3035

3036

2544

3036

2544

2545

3037

3038

2546

3038

2546

2547

3039

3040

2548

3040

2548

2549

3041

3042

2550

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

401

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

402

1686
2553
1687
2555
1688
2557
1689
2559
1690
2561
1691
2563
1692
2565
1693
2567
1694
2569
1695
2571
1696
2573
1697
2575
1698
2577
1779
2739
1780
2741
1781
2743
1782
2745
1783
2747
1784
2749
1785
2751
1786
2753
1787
2755
1788
2757
1789
2759
1790
2761
1791
2763
1792
2765
1793
2767
1794
2769
1795
2771
1796
2773
1797
2775
1798
2777
1799
2779
1800

2
3045
2
3047
2
3049
2
3051
2
3053
2
3055
2
3057
2
3059
2
3061
2
3063
2
3065
2
3067
2
3069
2
3231
2
3233
2
3235
2
3237
2
3239
2
3241
2
3243
2
3245
2
3247
2
3249
2
3251
2
3253
2
3255
2
3257
2
3259
2
3261
2
3263
2
3265
2
3267
2
3269
2
3271
2

3042

2550

2551

3043

3044

2552

3044

2552

2553

3045

3046

2554

3046

2554

2555

3047

3048

2556

3048

2556

2557

3049

3050

2558

3050

2558

2559

3051

3052

2560

3052

2560

2561

3053

3054

2562

3054

2562

2563

3055

3056

2564

3056

2564

2565

3057

3058

2566

3058

2566

2567

3059

3060

2568

3060

2568

2569

3061

3062

2570

3062

2570

2571

3063

3064

2572

3064

2572

2573

3065

3066

2574

3066

2574

2575

3067

3068

2576

3068

2576

2577

3069

3230

2738

3230

2738

2739

3231

3232

2740

3232

2740

2741

3233

3234

2742

3234

2742

2743

3235

3236

2744

3236

2744

2745

3237

3238

2746

3238

2746

2747

3239

3240

2748

3240

2748

2749

3241

3242

2750

3242

2750

2751

3243

3244

2752

3244

2752

2753

3245

3246

2754

3246

2754

2755

3247

3248

2756

3248

2756

2757

3249

3250

2758

3250

2758

2759

3251

3252

2760

3252

2760

2761

3253

3254

2762

3254

2762

2763

3255

3256

2764

3256

2764

2765

3257

3258

2766

3258

2766

2767

3259

3260

2768

3260

2768

2769

3261

3262

2770

3262

2770

2771

3263

3264

2772

3264

2772

2773

3265

3266

2774

3266

2774

2775

3267

3268

2776

3268

2776

2777

3269

3270

2778

3270

2778

2779

3271

3272

2780

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2781
1801
2783
1802
2785
1803
2787
1804
2789
1805
2791
1806
2793
1807
2795
1808
2797
1809
2799
1810
2801
1811
2803
1812
2805
1813
2807
1814
2809
1815
2811
1816
2813
1817
2815
1818
2817
1819
2819
1820
2821
1821
2494
1822
2496
1823
2498
1824
2500
1825
2502
1826
2504
1827
2506
1828
2508
1829
2510
1830
2512
1831
2514
1832
2516
1833
2518
1834
2520

Altair Engineering

3273
2
3275
2
3277
2
3279
2
3281
2
3283
2
3285
2
3287
2
3289
2
3291
2
3293
2
3295
2
3297
2
3299
2
3301
2
3303
2
3305
2
3307
2
3309
2
3311
2
3313
2
2986
2
2988
2
2990
2
2992
2
2994
2
2996
2
2998
2
3000
2
3002
2
3004
2
3006
2
3008
2
3010
2
3012

3272

2780

2781

3273

3274

2782

3274

2782

2783

3275

3276

2784

3276

2784

2785

3277

3278

2786

3278

2786

2787

3279

3280

2788

3280

2788

2789

3281

3282

2790

3282

2790

2791

3283

3284

2792

3284

2792

2793

3285

3286

2794

3286

2794

2795

3287

3288

2796

3288

2796

2797

3289

3290

2798

3290

2798

2799

3291

3292

2800

3292

2800

2801

3293

3294

2802

3294

2802

2803

3295

3296

2804

3296

2804

2805

3297

3298

2806

3298

2806

2807

3299

3300

2808

3300

2808

2809

3301

3302

2810

3302

2810

2811

3303

3304

2812

3304

2812

2813

3305

3306

2814

3306

2814

2815

3307

3308

2816

3308

2816

2817

3309

3310

2818

3310

2818

2819

3311

3312

2820

29

30

33

28

3314

2822

3314

2822

2494

2986

3315

2823

3315

2823

2496

2988

3316

2824

3316

2824

2498

2990

3317

2825

3317

2825

2500

2992

3318

2826

3318

2826

2502

2994

3319

2827

3319

2827

2504

2996

3320

2828

3320

2828

2506

2998

3321

2829

3321

2829

2508

3000

3322

2830

3322

2830

2510

3002

3323

2831

3323

2831

2512

3004

3324

2832

3324

2832

2514

3006

3325

2833

3325

2833

2516

3008

3326

2834

3326

2834

2518

3010

3327

2835

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

403

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

404

1835
2522
1836
2524
1837
2526
1838
2528
1839
2530
1840
2532
1841
2534
1842
2536
1843
2538
1844
2540
1845
2542
1846
2544
1847
2546
1848
2548
1849
2550
1850
2552
1851
2554
1852
2556
1853
2558
1854
2560
1855
2562
1856
2564
1857
2566
1858
2568
1859
2570
1860
2572
1861
2574
1862
2576
1943
2738
1944
2740
1945
2742
1946
2744
1947
2746
1948
2748
1949

2
3014
2
3016
2
3018
2
3020
2
3022
2
3024
2
3026
2
3028
2
3030
2
3032
2
3034
2
3036
2
3038
2
3040
2
3042
2
3044
2
3046
2
3048
2
3050
2
3052
2
3054
2
3056
2
3058
2
3060
2
3062
2
3064
2
3066
2
3068
2
3230
2
3232
2
3234
2
3236
2
3238
2
3240
2

3327

2835

2520

3012

3328

2836

3328

2836

2522

3014

3329

2837

3329

2837

2524

3016

3330

2838

3330

2838

2526

3018

3331

2839

3331

2839

2528

3020

3332

2840

3332

2840

2530

3022

3333

2841

3333

2841

2532

3024

3334

2842

3334

2842

2534

3026

3335

2843

3335

2843

2536

3028

3336

2844

3336

2844

2538

3030

3337

2845

3337

2845

2540

3032

3338

2846

3338

2846

2542

3034

3339

2847

3339

2847

2544

3036

3340

2848

3340

2848

2546

3038

3341

2849

3341

2849

2548

3040

3342

2850

3342

2850

2550

3042

3343

2851

3343

2851

2552

3044

3344

2852

3344

2852

2554

3046

3345

2853

3345

2853

2556

3048

3346

2854

3346

2854

2558

3050

3347

2855

3347

2855

2560

3052

3348

2856

3348

2856

2562

3054

3349

2857

3349

2857

2564

3056

3350

2858

3350

2858

2566

3058

3351

2859

3351

2859

2568

3060

3352

2860

3352

2860

2570

3062

3353

2861

3353

2861

2572

3064

3354

2862

3354

2862

2574

3066

3355

2863

3355

2863

2576

3068

3436

2944

3436

2944

2738

3230

3437

2945

3437

2945

2740

3232

3438

2946

3438

2946

2742

3234

3439

2947

3439

2947

2744

3236

3440

2948

3440

2948

2746

3238

3441

2949

3441

2949

2748

3240

3442

2950

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2750
1950
2752
1951
2754
1952
2756
1953
2758
1954
2760
1955
2762
1956
2764
1957
2766
1958
2768
1959
2770
1960
2772
1961
2774
1962
2776
1963
2778
1964
2780
1965
2782
1966
2784
1967
2786
1968
2788
1969
2790
1970
2792
1971
2794
1972
2796
1973
2798
1974
2800
1975
2802
1976
2804
1977
2806
1978
2808
1979
2810
1980
2812
1981
2814
1982
2816
1983
2818

Altair Engineering

3242
2
3244
2
3246
2
3248
2
3250
2
3252
2
3254
2
3256
2
3258
2
3260
2
3262
2
3264
2
3266
2
3268
2
3270
2
3272
2
3274
2
3276
2
3278
2
3280
2
3282
2
3284
2
3286
2
3288
2
3290
2
3292
2
3294
2
3296
2
3298
2
3300
2
3302
2
3304
2
3306
2
3308
2
3310

3442

2950

2750

3242

3443

2951

3443

2951

2752

3244

3444

2952

3444

2952

2754

3246

3445

2953

3445

2953

2756

3248

3446

2954

3446

2954

2758

3250

3447

2955

3447

2955

2760

3252

3448

2956

3448

2956

2762

3254

3449

2957

3449

2957

2764

3256

3450

2958

3450

2958

2766

3258

3451

2959

3451

2959

2768

3260

3452

2960

3452

2960

2770

3262

3453

2961

3453

2961

2772

3264

3454

2962

3454

2962

2774

3266

3455

2963

3455

2963

2776

3268

3456

2964

3456

2964

2778

3270

3457

2965

3457

2965

2780

3272

3458

2966

3458

2966

2782

3274

3459

2967

3459

2967

2784

3276

3460

2968

3460

2968

2786

3278

3461

2969

3461

2969

2788

3280

3462

2970

3462

2970

2790

3282

3463

2971

3463

2971

2792

3284

3464

2972

3464

2972

2794

3286

3465

2973

3465

2973

2796

3288

3466

2974

3466

2974

2798

3290

3467

2975

3467

2975

2800

3292

3468

2976

3468

2976

2802

3294

3469

2977

3469

2977

2804

3296

3470

2978

3470

2978

2806

3298

3471

2979

3471

2979

2808

3300

3472

2980

3472

2980

2810

3302

3473

2981

3473

2981

2812

3304

3474

2982

3474

2982

2814

3306

3475

2983

3475

2983

2816

3308

3476

2984

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

405

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

406

1984
2820
1985
690
1986
692
1987
694
1988
696
1989
698
1990
700
1991
702
1992
704
1993
706
1994
708
1995
710
1996
712
1997
714
1998
716
1999
718
2000
720
2001
722
2002
724
2003
726
2004
728
2005
730
2006
732
2007
734
2008
736
2009
738
2010
740
2011
742
2012
744
2013
746
2014
748
2015
750
2016
752
2017
754
2018

2
3312
2
3479
2
3481
2
3483
2
3485
2
3487
2
3489
2
3491
2
3493
2
3495
2
3497
2
3499
2
3501
2
3503
2
3505
2
3507
2
3509
2
3511
2
3513
2
3515
2
3517
2
3519
2
3521
2
3523
2
3525
2
3527
2
3529
2
3531
2
3533
2
3535
2
3537
2
3539
2
3541
2
3543
2

3476

2984

2818

3310

3477

2985

32

10

24

3478

34

3478

34

690

3479

3480

38

3480

38

692

3481

3482

42

3482

42

694

3483

3484

46

3484

46

696

3485

3486

50

3486

50

698

3487

3488

54

3488

54

700

3489

3490

58

3490

58

702

3491

3492

62

3492

62

704

3493

3494

66

3494

66

706

3495

3496

70

3496

70

708

3497

3498

74

3498

74

710

3499

3500

78

3500

78

712

3501

3502

82

3502

82

714

3503

3504

86

3504

86

716

3505

3506

90

3506

90

718

3507

3508

94

3508

94

720

3509

3510

98

3510

98

722

3511

3512

102

3512

102

724

3513

3514

106

3514

106

726

3515

3516

110

3516

110

728

3517

3518

114

3518

114

730

3519

3520

118

3520

118

732

3521

3522

122

3522

122

734

3523

3524

126

3524

126

736

3525

3526

130

3526

130

738

3527

3528

134

3528

134

740

3529

3530

138

3530

138

742

3531

3532

142

3532

142

744

3533

3534

146

3534

146

746

3535

3536

150

3536

150

748

3537

3538

154

3538

154

750

3539

3540

158

3540

158

752

3541

3542

162

3542

162

754

3543

3544

166

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

756
2019
758
2020
760
2021
762
2022
764
2023
766
2024
768
2025
770
2026
772
2107
934
2108
936
2109
938
2110
940
2111
942
2112
944
2113
946
2114
948
2115
950
2116
952
2117
954
2118
956
2119
958
2120
960
2121
962
2122
964
2123
966
2124
968
2125
970
2126
972
2127
974
2128
976
2129
978
2130
980
2131
982
2132
984

Altair Engineering

3545
2
3547
2
3549
2
3551
2
3553
2
3555
2
3557
2
3559
2
3561
2
3723
2
3725
2
3727
2
3729
2
3731
2
3733
2
3735
2
3737
2
3739
2
3741
2
3743
2
3745
2
3747
2
3749
2
3751
2
3753
2
3755
2
3757
2
3759
2
3761
2
3763
2
3765
2
3767
2
3769
2
3771
2
3773

3544

166

756

3545

3546

170

3546

170

758

3547

3548

174

3548

174

760

3549

3550

178

3550

178

762

3551

3552

182

3552

182

764

3553

3554

186

3554

186

766

3555

3556

190

3556

190

768

3557

3558

194

3558

194

770

3559

3560

198

3560

198

772

3561

3722

522

3722

522

934

3723

3724

526

3724

526

936

3725

3726

530

3726

530

938

3727

3728

534

3728

534

940

3729

3730

538

3730

538

942

3731

3732

542

3732

542

944

3733

3734

546

3734

546

946

3735

3736

550

3736

550

948

3737

3738

554

3738

554

950

3739

3740

558

3740

558

952

3741

3742

562

3742

562

954

3743

3744

566

3744

566

956

3745

3746

570

3746

570

958

3747

3748

574

3748

574

960

3749

3750

578

3750

578

962

3751

3752

582

3752

582

964

3753

3754

586

3754

586

966

3755

3756

590

3756

590

968

3757

3758

594

3758

594

970

3759

3760

598

3760

598

972

3761

3762

602

3762

602

974

3763

3764

606

3764

606

976

3765

3766

610

3766

610

978

3767

3768

614

3768

614

980

3769

3770

618

3770

618

982

3771

3772

622

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

407

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

408

2133
986
2134
988
2135
990
2136
992
2137
994
2138
996
2139
998
2140
1000
2141
1002
2142
1004
2143
1006
2144
1008
2145
1010
2146
1012
2147
1014
2148
1016
2149
34
2150
38
2151
42
2152
46
2153
50
2154
54
2155
58
2156
62
2157
66
2158
70
2159
74
2160
78
2161
82
2162
86
2163
90
2164
94
2165
98
2166
102
2167

2
3775
2
3777
2
3779
2
3781
2
3783
2
3785
2
3787
2
3789
2
3791
2
3793
2
3795
2
3797
2
3799
2
3801
2
3803
2
3805
2
3478
2
3480
2
3482
2
3484
2
3486
2
3488
2
3490
2
3492
2
3494
2
3496
2
3498
2
3500
2
3502
2
3504
2
3506
2
3508
2
3510
2
3512
2

3772

622

984

3773

3774

626

3774

626

986

3775

3776

630

3776

630

988

3777

3778

634

3778

634

990

3779

3780

638

3780

638

992

3781

3782

642

3782

642

994

3783

3784

646

3784

646

996

3785

3786

650

3786

650

998

3787

3788

654

3788

654

1000

3789

3790

658

3790

658

1002

3791

3792

662

3792

662

1004

3793

3794

666

3794

666

1006

3795

3796

670

3796

670

1008

3797

3798

674

3798

674

1010

3799

3800

678

3800

678

1012

3801

3802

682

3802

682

1014

3803

3804

686

31

11

10

32

2495

35

2495

35

34

3478

2497

39

2497

39

38

3480

2499

43

2499

43

42

3482

2501

47

2501

47

46

3484

2503

51

2503

51

50

3486

2505

55

2505

55

54

3488

2507

59

2507

59

58

3490

2509

63

2509

63

62

3492

2511

67

2511

67

66

3494

2513

71

2513

71

70

3496

2515

75

2515

75

74

3498

2517

79

2517

79

78

3500

2519

83

2519

83

82

3502

2521

87

2521

87

86

3504

2523

91

2523

91

90

3506

2525

95

2525

95

94

3508

2527

99

2527

99

98

3510

2529

103

2529

103

102

3512

2531

107

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

106
2168
110
2169
114
2170
118
2171
122
2172
126
2173
130
2174
134
2175
138
2176
142
2177
146
2178
150
2179
154
2180
158
2181
162
2182
166
2183
170
2184
174
2185
178
2186
182
2187
186
2188
190
2189
194
2190
198
2271
522
2272
526
2273
530
2274
534
2275
538
2276
542
2277
546
2278
550
2279
554
2280
558
2281
562

Altair Engineering

3514
2
3516
2
3518
2
3520
2
3522
2
3524
2
3526
2
3528
2
3530
2
3532
2
3534
2
3536
2
3538
2
3540
2
3542
2
3544
2
3546
2
3548
2
3550
2
3552
2
3554
2
3556
2
3558
2
3560
2
3722
2
3724
2
3726
2
3728
2
3730
2
3732
2
3734
2
3736
2
3738
2
3740
2
3742

2531

107

106

3514

2533

111

2533

111

110

3516

2535

115

2535

115

114

3518

2537

119

2537

119

118

3520

2539

123

2539

123

122

3522

2541

127

2541

127

126

3524

2543

131

2543

131

130

3526

2545

135

2545

135

134

3528

2547

139

2547

139

138

3530

2549

143

2549

143

142

3532

2551

147

2551

147

146

3534

2553

151

2553

151

150

3536

2555

155

2555

155

154

3538

2557

159

2557

159

158

3540

2559

163

2559

163

162

3542

2561

167

2561

167

166

3544

2563

171

2563

171

170

3546

2565

175

2565

175

174

3548

2567

179

2567

179

178

3550

2569

183

2569

183

182

3552

2571

187

2571

187

186

3554

2573

191

2573

191

190

3556

2575

195

2575

195

194

3558

2577

199

2577

199

198

3560

2739

523

2739

523

522

3722

2741

527

2741

527

526

3724

2743

531

2743

531

530

3726

2745

535

2745

535

534

3728

2747

539

2747

539

538

3730

2749

543

2749

543

542

3732

2751

547

2751

547

546

3734

2753

551

2753

551

550

3736

2755

555

2755

555

554

3738

2757

559

2757

559

558

3740

2759

563

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

409

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

410

2282
566
2283
570
2284
574
2285
578
2286
582
2287
586
2288
590
2289
594
2290
598
2291
602
2292
606
2293
610
2294
614
2295
618
2296
622
2297
626
2298
630
2299
634
2300
638
2301
642
2302
646
2303
650
2304
654
2305
658
2306
662
2307
666
2308
670
2309
674
2310
678
2311
682
2312
686
2313
3479
2314
3481
2315
3483
2316

2
3744
2
3746
2
3748
2
3750
2
3752
2
3754
2
3756
2
3758
2
3760
2
3762
2
3764
2
3766
2
3768
2
3770
2
3772
2
3774
2
3776
2
3778
2
3780
2
3782
2
3784
2
3786
2
3788
2
3790
2
3792
2
3794
2
3796
2
3798
2
3800
2
3802
2
3804
2
3807
2
3809
2
3811
2

2759

563

562

3742

2761

567

2761

567

566

3744

2763

571

2763

571

570

3746

2765

575

2765

575

574

3748

2767

579

2767

579

578

3750

2769

583

2769

583

582

3752

2771

587

2771

587

586

3754

2773

591

2773

591

590

3756

2775

595

2775

595

594

3758

2777

599

2777

599

598

3760

2779

603

2779

603

602

3762

2781

607

2781

607

606

3764

2783

611

2783

611

610

3766

2785

615

2785

615

614

3768

2787

619

2787

619

618

3770

2789

623

2789

623

622

3772

2791

627

2791

627

626

3774

2793

631

2793

631

630

3776

2795

635

2795

635

634

3778

2797

639

2797

639

638

3780

2799

643

2799

643

642

3782

2801

647

2801

647

646

3784

2803

651

2803

651

650

3786

2805

655

2805

655

654

3788

2807

659

2807

659

658

3790

2809

663

2809

663

662

3792

2811

667

2811

667

666

3794

2813

671

2813

671

670

3796

2815

675

2815

675

674

3798

2817

679

2817

679

678

3800

2819

683

2819

683

682

3802

2821

687

26

32

24

25

3806

3478

3806

3478

3479

3807

3808

3480

3808

3480

3481

3809

3810

3482

3810

3482

3483

3811

3812

3484

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

3485
2317
3487
2318
3489
2319
3491
2320
3493
2321
3495
2322
3497
2323
3499
2324
3501
2325
3503
2326
3505
2327
3507
2328
3509
2329
3511
2330
3513
2331
3515
2332
3517
2333
3519
2334
3521
2335
3523
2336
3525
2337
3527
2338
3529
2339
3531
2340
3533
2341
3535
2342
3537
2343
3539
2344
3541
2345
3543
2346
3545
2347
3547
2348
3549
2349
3551
2350
3553

Altair Engineering

3813
2
3815
2
3817
2
3819
2
3821
2
3823
2
3825
2
3827
2
3829
2
3831
2
3833
2
3835
2
3837
2
3839
2
3841
2
3843
2
3845
2
3847
2
3849
2
3851
2
3853
2
3855
2
3857
2
3859
2
3861
2
3863
2
3865
2
3867
2
3869
2
3871
2
3873
2
3875
2
3877
2
3879
2
3881

3812

3484

3485

3813

3814

3486

3814

3486

3487

3815

3816

3488

3816

3488

3489

3817

3818

3490

3818

3490

3491

3819

3820

3492

3820

3492

3493

3821

3822

3494

3822

3494

3495

3823

3824

3496

3824

3496

3497

3825

3826

3498

3826

3498

3499

3827

3828

3500

3828

3500

3501

3829

3830

3502

3830

3502

3503

3831

3832

3504

3832

3504

3505

3833

3834

3506

3834

3506

3507

3835

3836

3508

3836

3508

3509

3837

3838

3510

3838

3510

3511

3839

3840

3512

3840

3512

3513

3841

3842

3514

3842

3514

3515

3843

3844

3516

3844

3516

3517

3845

3846

3518

3846

3518

3519

3847

3848

3520

3848

3520

3521

3849

3850

3522

3850

3522

3523

3851

3852

3524

3852

3524

3525

3853

3854

3526

3854

3526

3527

3855

3856

3528

3856

3528

3529

3857

3858

3530

3858

3530

3531

3859

3860

3532

3860

3532

3533

3861

3862

3534

3862

3534

3535

3863

3864

3536

3864

3536

3537

3865

3866

3538

3866

3538

3539

3867

3868

3540

3868

3540

3541

3869

3870

3542

3870

3542

3543

3871

3872

3544

3872

3544

3545

3873

3874

3546

3874

3546

3547

3875

3876

3548

3876

3548

3549

3877

3878

3550

3878

3550

3551

3879

3880

3552

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

411

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

412

2351
3555
2352
3557
2353
3559
2354
3561
2435
3723
2436
3725
2437
3727
2438
3729
2439
3731
2440
3733
2441
3735
2442
3737
2443
3739
2444
3741
2445
3743
2446
3745
2447
3747
2448
3749
2449
3751
2450
3753
2451
3755
2452
3757
2453
3759
2454
3761
2455
3763
2456
3765
2457
3767
2458
3769
2459
3771
2460
3773
2461
3775
2462
3777
2463
3779
2464
3781
2465

2
3883
2
3885
2
3887
2
3889
2
4051
2
4053
2
4055
2
4057
2
4059
2
4061
2
4063
2
4065
2
4067
2
4069
2
4071
2
4073
2
4075
2
4077
2
4079
2
4081
2
4083
2
4085
2
4087
2
4089
2
4091
2
4093
2
4095
2
4097
2
4099
2
4101
2
4103
2
4105
2
4107
2
4109
2

3880

3552

3553

3881

3882

3554

3882

3554

3555

3883

3884

3556

3884

3556

3557

3885

3886

3558

3886

3558

3559

3887

3888

3560

3888

3560

3561

3889

4050

3722

4050

3722

3723

4051

4052

3724

4052

3724

3725

4053

4054

3726

4054

3726

3727

4055

4056

3728

4056

3728

3729

4057

4058

3730

4058

3730

3731

4059

4060

3732

4060

3732

3733

4061

4062

3734

4062

3734

3735

4063

4064

3736

4064

3736

3737

4065

4066

3738

4066

3738

3739

4067

4068

3740

4068

3740

3741

4069

4070

3742

4070

3742

3743

4071

4072

3744

4072

3744

3745

4073

4074

3746

4074

3746

3747

4075

4076

3748

4076

3748

3749

4077

4078

3750

4078

3750

3751

4079

4080

3752

4080

3752

3753

4081

4082

3754

4082

3754

3755

4083

4084

3756

4084

3756

3757

4085

4086

3758

4086

3758

3759

4087

4088

3760

4088

3760

3761

4089

4090

3762

4090

3762

3763

4091

4092

3764

4092

3764

3765

4093

4094

3766

4094

3766

3767

4095

4096

3768

4096

3768

3769

4097

4098

3770

4098

3770

3771

4099

4100

3772

4100

3772

3773

4101

4102

3774

4102

3774

3775

4103

4104

3776

4104

3776

3777

4105

4106

3778

4106

3778

3779

4107

4108

3780

4108

3780

3781

4109

4110

3782

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

3783
2466
3785
2467
3787
2468
3789
2469
3791
2470
3793
2471
3795
2472
3797
2473
3799
2474
3801
2475
3803
2476
3805
2477
3478
2478
3480
2479
3482
2480
3484
2481
3486
2482
3488
2483
3490
2484
3492
2485
3494
2486
3496
2487
3498
2488
3500
2489
3502
2490
3504
2491
3506
2492
3508
2493
3510
2494
3512
2495
3514
2496
3516
2497
3518
2498
3520
2499
3522

Altair Engineering

4111
2
4113
2
4115
2
4117
2
4119
2
4121
2
4123
2
4125
2
4127
2
4129
2
4131
2
4133
2
3806
2
3808
2
3810
2
3812
2
3814
2
3816
2
3818
2
3820
2
3822
2
3824
2
3826
2
3828
2
3830
2
3832
2
3834
2
3836
2
3838
2
3840
2
3842
2
3844
2
3846
2
3848
2
3850

4110

3782

3783

4111

4112

3784

4112

3784

3785

4113

4114

3786

4114

3786

3787

4115

4116

3788

4116

3788

3789

4117

4118

3790

4118

3790

3791

4119

4120

3792

4120

3792

3793

4121

4122

3794

4122

3794

3795

4123

4124

3796

4124

3796

3797

4125

4126

3798

4126

3798

3799

4127

4128

3800

4128

3800

3801

4129

4130

3802

4130

3802

3803

4131

4132

3804

27

31

32

26

2987

2495

2987

2495

3478

3806

2989

2497

2989

2497

3480

3808

2991

2499

2991

2499

3482

3810

2993

2501

2993

2501

3484

3812

2995

2503

2995

2503

3486

3814

2997

2505

2997

2505

3488

3816

2999

2507

2999

2507

3490

3818

3001

2509

3001

2509

3492

3820

3003

2511

3003

2511

3494

3822

3005

2513

3005

2513

3496

3824

3007

2515

3007

2515

3498

3826

3009

2517

3009

2517

3500

3828

3011

2519

3011

2519

3502

3830

3013

2521

3013

2521

3504

3832

3015

2523

3015

2523

3506

3834

3017

2525

3017

2525

3508

3836

3019

2527

3019

2527

3510

3838

3021

2529

3021

2529

3512

3840

3023

2531

3023

2531

3514

3842

3025

2533

3025

2533

3516

3844

3027

2535

3027

2535

3518

3846

3029

2537

3029

2537

3520

3848

3031

2539

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

413

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

414

2500
3524
2501
3526
2502
3528
2503
3530
2504
3532
2505
3534
2506
3536
2507
3538
2508
3540
2509
3542
2510
3544
2511
3546
2512
3548
2513
3550
2514
3552
2515
3554
2516
3556
2517
3558
2518
3560
2599
3722
2600
3724
2601
3726
2602
3728
2603
3730
2604
3732
2605
3734
2606
3736
2607
3738
2608
3740
2609
3742
2610
3744
2611
3746
2612
3748
2613
3750
2614

2
3852
2
3854
2
3856
2
3858
2
3860
2
3862
2
3864
2
3866
2
3868
2
3870
2
3872
2
3874
2
3876
2
3878
2
3880
2
3882
2
3884
2
3886
2
3888
2
4050
2
4052
2
4054
2
4056
2
4058
2
4060
2
4062
2
4064
2
4066
2
4068
2
4070
2
4072
2
4074
2
4076
2
4078
2

3031

2539

3522

3850

3033

2541

3033

2541

3524

3852

3035

2543

3035

2543

3526

3854

3037

2545

3037

2545

3528

3856

3039

2547

3039

2547

3530

3858

3041

2549

3041

2549

3532

3860

3043

2551

3043

2551

3534

3862

3045

2553

3045

2553

3536

3864

3047

2555

3047

2555

3538

3866

3049

2557

3049

2557

3540

3868

3051

2559

3051

2559

3542

3870

3053

2561

3053

2561

3544

3872

3055

2563

3055

2563

3546

3874

3057

2565

3057

2565

3548

3876

3059

2567

3059

2567

3550

3878

3061

2569

3061

2569

3552

3880

3063

2571

3063

2571

3554

3882

3065

2573

3065

2573

3556

3884

3067

2575

3067

2575

3558

3886

3069

2577

3069

2577

3560

3888

3231

2739

3231

2739

3722

4050

3233

2741

3233

2741

3724

4052

3235

2743

3235

2743

3726

4054

3237

2745

3237

2745

3728

4056

3239

2747

3239

2747

3730

4058

3241

2749

3241

2749

3732

4060

3243

2751

3243

2751

3734

4062

3245

2753

3245

2753

3736

4064

3247

2755

3247

2755

3738

4066

3249

2757

3249

2757

3740

4068

3251

2759

3251

2759

3742

4070

3253

2761

3253

2761

3744

4072

3255

2763

3255

2763

3746

4074

3257

2765

3257

2765

3748

4076

3259

2767

3259

2767

3750

4078

3261

2769

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
3752
4080
CHEXA
2615
2
3261
2769
3752
4080
3263
2771
+
3754
4082
CHEXA
2616
2
3263
2771
3754
4082
3265
2773
+
3756
4084
CHEXA
2617
2
3265
2773
3756
4084
3267
2775
+
3758
4086
CHEXA
2618
2
3267
2775
3758
4086
3269
2777
+
3760
4088
CHEXA
2619
2
3269
2777
3760
4088
3271
2779
+
3762
4090
CHEXA
2620
2
3271
2779
3762
4090
3273
2781
+
3764
4092
CHEXA
2621
2
3273
2781
3764
4092
3275
2783
+
3766
4094
CHEXA
2622
2
3275
2783
3766
4094
3277
2785
+
3768
4096
CHEXA
2623
2
3277
2785
3768
4096
3279
2787
+
3770
4098
CHEXA
2624
2
3279
2787
3770
4098
3281
2789
+
3772
4100
CHEXA
2625
2
3281
2789
3772
4100
3283
2791
+
3774
4102
CHEXA
2626
2
3283
2791
3774
4102
3285
2793
+
3776
4104
CHEXA
2627
2
3285
2793
3776
4104
3287
2795
+
3778
4106
CHEXA
2628
2
3287
2795
3778
4106
3289
2797
+
3780
4108
CHEXA
2629
2
3289
2797
3780
4108
3291
2799
+
3782
4110
CHEXA
2630
2
3291
2799
3782
4110
3293
2801
+
3784
4112
CHEXA
2631
2
3293
2801
3784
4112
3295
2803
+
3786
4114
CHEXA
2632
2
3295
2803
3786
4114
3297
2805
+
3788
4116
CHEXA
2633
2
3297
2805
3788
4116
3299
2807
+
3790
4118
CHEXA
2634
2
3299
2807
3790
4118
3301
2809
+
3792
4120
CHEXA
2635
2
3301
2809
3792
4120
3303
2811
+
3794
4122
CHEXA
2636
2
3303
2811
3794
4122
3305
2813
+
3796
4124
CHEXA
2637
2
3305
2813
3796
4124
3307
2815
+
3798
4126
CHEXA
2638
2
3307
2815
3798
4126
3309
2817
+
3800
4128
CHEXA
2639
2
3309
2817
3800
4128
3311
2819
+
3802
4130
CHEXA
2640
2
3311
2819
3802
4130
3313
2821
+
3804
4132
$
$HMMOVE
2
$
17THRU
58
139THRU
222
303THRU
386
$
467THRU
550
631THRU
714
795THRU
878
$
959THRU
1042
1123THRU
1206
1287THRU
1370
$
1451THRU
1534
1615THRU
1698
1779THRU
1862
$
1943THRU
2026
2107THRU
2190
2271THRU
2354
$
2435THRU
2518
2599THRU
2640
$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name and color information for generic components
$
$$------------------------------------------------------------------------------$
$HMNAME COMP
2"Air"
2 "Air" 5
$HWCOLOR COMP
2
5
$

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

415

$HMNAME COMP
$HWCOLOR COMP
$
$HMNAME COMP
$HWCOLOR COMP
$
$
$HMDPRP
$
17THRU
$
467THRU
$
959THRU
$
1451THRU
$
1943THRU
$
2435THRU
$
6122
6125
$
7647
7652
$

5"Piston"
5
8
6"absorber"
6
3

58
139THRU
550
631THRU
1042
1123THRU
1534
1615THRU
2026
2107THRU
2518
2599THRU
6520THRU
6521
7945
7948
7955

222
714
1206
1698
2190
2640
6523

303THRU
795THRU
1287THRU
1779THRU
2271THRU
5627
5629
6528
6954

386
878
1370
1862
2354
6116
7220

$
$$
$$ PSHELL Data
$$
$
$
$
$
$
$
$
$HMNAME PROP
1"tube" 4
$HWCOLOR PROP
1
52
PSHELL
1
20.1
2
2
0.0
$$
$$ PSOLID Data
$$
$HMNAME PROP
2"Air" 5
$HWCOLOR PROP
2
4
PSOLID
2
1
PFLUID
$$
$$ MAT1 Data
$$
$HMNAME MAT
2"alum" "MAT1"
$HWCOLOR MAT
2
3
MAT1
21.0+7
0.3
0.000254
$$
$$ MAT10 Data
$HMNAME MAT
1"Air" "MAT10"
$HWCOLOR MAT
1
3
MAT10
1
1.21-7 13000.0
$$
$$------------------------------------------------------------------------------$
$$ HyperMesh Commands for loadcollectors name and color information $
$$------------------------------------------------------------------------------$
$HMNAME LOADCOL
2"spc"
$HWCOLOR LOADCOL
2
6
$$
$HMNAME LOADCOL
8"Force"
$HWCOLOR LOADCOL
8
7
$$
$HMNAME LOADCOL
12"SPC"
$HWCOLOR LOADCOL
12
5
$$
$$
$$ FREQi cards
$$
$HMNAME LOADCOL
3"Freq"
$HWCOLOR LOADCOL
3
6
$FREQ1
3
0.0
5.0
600
FREQ
3480.

416

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$
$$
$$ RLOAD1 cards
$$
$HMNAME LOADCOL
6"Rload"
$HWCOLOR LOADCOL
6
6
RLOAD1
6
8
$$
$$
$$ TABLED1 cards
$$
$HMNAME LOADCOL
7"Table"
$HWCOLOR LOADCOL
7
6
TABLED1
7 LINEAR LINEAR
+
0.0
1.0 3000.0
1.0ENDT
$$
$HMNAME LOADCOL
10"reactance"
$HWCOLOR LOADCOL
10
5
TABLED1
10 LINEAR LINEAR
+
0.0 0.00154 3000.0 0.00154ENDT
$$
$HMNAME LOADCOL
11"Impedance"
$HWCOLOR LOADCOL
11
5
TABLED1
11 LINEAR LINEAR
+
0.0
0.0 3000.0
0.0ENDT
$$
$$
$$ DLOAD cards
$$
$HMNAME LOADCOL
9"Dload"
$HWCOLOR LOADCOL
9
6
DLOAD
91.0
1.0
6
$$
$$ EIGRL cards
$$
$HMNAME LOADCOL
4"EigrlTube"
$HWCOLOR LOADCOL
4
6
EIGRL
4
5
$HMNAME LOADCOL
5"EigrlAir"
$HWCOLOR LOADCOL
5
6
EIGRL
5
30
$$
$$ SPC Data
$$
SPC1
12123456 6776
thru
6800
spcd
86776
3
1.0
spcd
86777
3
1.0
spcd
86778
3
1.0
spcd
86779
3
1.0
spcd
86780
3
1.0
spcd
86781
3
1.0
spcd
86782
3
1.0
spcd
86783
3
1.0
spcd
86784
3
1.0
spcd
86785
3
1.0
spcd
86786
3
1.0
spcd
86788
3
1.0
spcd
86789
3
1.0
spcd
86790
3
1.0
spcd
86791
3
1.0
spcd
86792
3
1.0
spcd
86793
3
1.0
spcd
86794
3
1.0
spcd
86795
3
1.0
spcd
86796
3
1.0
spcd
86797
3
1.0
spcd
86798
3
1.0
spcd
86799
3
1.0
spcd
86800
3
1.0

Altair Engineering

VELO

MASS
MASS

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

417

$
$ DAREA Data
$
$$
$$ DAREA Data
$$
DAREA
8
6798
3-15.0
$$
$$
CAABSF
7957
5
689
688
687
686
CAABSF
7960
5
1017
689
686
1016
CAABSF
7964
5
1345
1344
688
689
CAABSF
7969
5
1509
1345
689
1017
CAABSF
7972
5
2165
2164
2163
2162
CAABSF
7977
5
688
2165
2162
687
CAABSF
7978
5
4133
3805
3804
4132
CAABSF
7980
5
2493
2492
2164
2165
CAABSF
7984
5
1344
2493
2165
688
CAABSF
7985
5
2821
687
2162
2820
CAABSF
7988
5
2820
2162
2163
2985
CAABSF
7990
5
3313
2821
2820
3312
CAABSF
7994
5
3312
2820
2985
3477
CAABSF
7996
5
3805
1016
686
3804
CAABSF
7998
5
3804
686
687
2821
CAABSF
8003
5
4132
3804
2821
3313
PAABSF
5
11
10
ENDDATA
$$
$$------------------------------------------------------------------------------$$
$$
Data Definition for AutoDV
$$
$$------------------------------------------------------------------------------$$
$$
$$-----------------------------------------------------------------------------$$
$$
Design Variables Card for Control Perturbations
$$
$$-----------------------------------------------------------------------------$$
$
$------------------------------------------------------------------------------$
$
Domain Element Definitions
$
$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$$
$$
Nodeset Definitions
$$
$$------------------------------------------------------------------------------$$
$$ Design domain node sets
$$
$$------------------------------------------------------------------------------$$
$$
Control Perturbation
$$
$$------------------------------------------------------------------------------$$
$$
$$
$$ CONTROL PERTURBATION Data
$$

ALTDOCTAG "0mjpRI@DXd^3_0ASnbi`;l;q6A23R@9_67hgW8R?OiZ]
Eq:PeN``A;WXh3ITgJeq5NZRd5jSHQK3X@:`a12;n4qD_I^RYMo"
ADI0.1.0 2011-02-11T20:16:20 0of1 OSQA
ENDDOCTAG

418

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Element identification numbers should be unique with respect to all other element
identification numbers.

2.

If only G1 is specified, then a point impedance is assumed. If G1 and G2 are specified,


then a line impedance is assumed. If G1, G2 and G3 are specified, then an impedance is
associated with the area of the triangular face. If G1 through G4 are specified, then an
impedance is associated with the quadrilateral face.

3.

The CAABSF element must connect entirely to fluid points on the fluid-structure
boundary.

4.

This card is represented as a CAABSF element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

419

CAALOAD
Bulk Data Entry
CAALOAD Pressure from CFD Analysis
Description
The CAALOAD bulk data entry defines the CFD pressure that is transferred to the structural
side for frequency response analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C AALOAD

SID

C AAID

SRFID

AC SC AL

PSC AL

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C AALOAD

110

20

1.0

(6)

Field

Contents

SID

Identification number of a dynamic load set.

(7)

(8)

(9)

(10)

No default (Integer > 0)


CAAID

Identification number of the H3D file (loadID) specified by ASSIGN,H3DCAA (See


comments 1 and 2).
Default = no default (Integer > 0)

SRFID

Identification number of a SURF bulk data entry that defines the surface where
CFD pressure is applicable (See comment 1).
Default = 0 (Integer > 0)

ACSCAL Scale factor of the acoustic source term.


Default = 1.0 (Real > 0)

420

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

PSCAL

Scale factor of CFD pressure.


Default = 1.0 (Real > 0)

Comments
1.

The surface GRIDs associated with the CFD pressure must be fluid grids. The pressures
from CFD analysis at each loading frequency are stored in an H3D file. This H3D file can be
referenced using the ASSIGN I/O Options Entry (ASSIGN, H3DCAA, loadID, and filename).

2.

The pressure from the fluid grids will be transferred to structural grids for frequency
response analysis.

3.

CAALOAD can be chosen as a dynamic load in the I/O Options or Subcase Information
sections with the command DLOAD = SID.

4.

The SID field in this CAALOAD entry must be unique with respect to other dynamic load
sets (ACSRCE, DLOAD, RLOAD1, RLOAD2, TLOAD1, and TLOAD2 entries).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

421

CBAR
Bulk Data Entry
CBAR Simple Beam Element Connection
Description
The CBAR bulk data entry defines a simple beam element (BAR) of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C BAR

EID

PID

GA

GB

X1/G0

X2

X3

OFFT

PA

PB

W1A

W2A

W3A

W1B

W2B

W3B

Example

(1)

(2)

(3)

(4)

(5)

(6)

C BAR

39

13

(7)

(8)

(9)

(10)

513

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

PID

Identification number of a PBAR or PBARL property entry.


Default = EID (Integer > 0)

GA,GB

422

Grid point identification numbers of connection points.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

X1,X2,X3

Components of vector v, at end A, measured at end A, parallel to


the components of the displacement coordinate system for GA, or
the basic coordinate system, to determine (with the vector from
end A to end B) the orientation of the element coordinate system
for the BAR element. See comment 5.
No default (Real)

G0

Grid point identification number to optionally supply X1, X2, X3.


Direction of orientation vector is GA to G0.
No default (Integer > 0)

OFFT

Character String specifying the interpretation of the offset vector


specification. See comment 5.
Default = GGG (Character or blank)

PA,PB

Pin flags for bar ends A and B, respectively. Used to remove


connections between the grid point and selected degrees-offreedom of the bar. The degrees-of-freedom are defined in the
elements coordinate system. The bar must have stiffness
associated with the PA and PB degrees-of-freedom to be released
by the pin flags. For example, if PA=4 is specified, the PBAR entry
must have a value for J, the torsion stiffness.
No default (Integer > 0; up to 5 of the unique digits 1-6 with no
embedded blanks)

W1A,W2A,W3A
W1B,W2B,W3B

Components of offset vectors wa and wb in displacement


coordinate systems at points GA and GB, respectively, or in the
element coordinate system. See comment 5.
Default = blank (Real or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

423

Fig 1: Bar element coordinate system (for C BAR element)

Fig 2: Moments and Internal Forces in the x-y Plane (for a C BAR element)

424

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Fig 3: Moments and Internal Forces in the x-z Plane (for a C BAR element)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

If there are no pin flags or offsets, the continuation may be omitted.

3.

G0 cannot be located at GA or GB.

4.

If X1/G0 is a positive integer and X2 and X3 are blank, then G0 is used to orient the
element, otherwise X1, X2, X3 is used.

5.

The OFFT character string specifies how the offset and orientation vector components
are computed. By default, the offset vectors are specified in the Global (local
displacement) coordinate system of each grid A and B, and the orientation vector is
specified in the Global coordinate system of grid A. Using the codes below, the offset
vector can be specified in the element coordinate system and the orientation vector can
be specified in the basic coordinate system. The valid character strings and their
meanings are shown below:
OFFT

Orientation Vector

End A Offset

End B Offset

GGG

Global

Global

Global

BGG

Basic

Global

Global

GGO

Global

Global

Element

BGO

Basic

Global

Element

GOG

Global

Element

Global

BOG

Basic

Element

Global

GOO

Global

Element

Element

BOO

Basic

Element

Element

The element system x-axis is defined from GA to GB. The orientation vector and the
element system x-axis are then used to define the z and y axes of the element system.
A vector is formed from the cross product of a vector going from Grid A to Grid B and the
orientation vector to create the element coordinate z-direction.
6.

Offset vectors are treated like rigid elements. The length of the offset vectors is not
affected by thermal loads.

7.

This card is represented as a bar2 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

425

CBEAM
Bulk Data Entry
CBEAM Beam Element Connection
Description
The CBEAM bulk data entry defines a beam element (BEAM) of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C BEAM

EID

PID

GA

GB

X1/G0

X2

X3

OFFT

PA

PB

W1A

W2A

W3A

W1B

W2B

W3B

Example

(1)

(2)

(3)

(4)

(5)

(6)

C BEAM

39

13

513

(7)

(8)

(9)

(10)

3.0

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

PID

Identification number of PBEAM or PBEAML property entry.


Default = EID (Integer > 0)

GA,GB

426

Grid point identification numbers of connection points.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

X1,X2,X3

Components of vector v, at end A, measured at the offset point for


end A, parallel to the components of the displacement coordinate
system for GA, or the basic coordinate system, to determine (with
the vector from offset end A to offset end B) the orientation of the
element coordinate system for the beam element. See comment 5.
No default (Real; See comment 2)

G0

Grid point identification number to optionally supply X1, X2, X3.


Direction of orientation vector is GA to G0.
No default (Integer > 0; See comment 2).

OFFT

Character string specifying the interpretation of the offset vector


specification. See comment 5.
Default = GGG (Character or blank)

PA, PB

Pin flags for beam ends A and B respectively. Used to remove


connections between the grid point and selected degrees-of-freedom
of the beam. The degrees-of-freedom are defined in the elements
coordinate system and the pin flags are applied at the offset ends of
the beam. The beam must have stiffness associated with the PA and
PB degrees-of-freedom to be released by the pin flags. For example,
if PA=4, the PBEAM entry must have a non-zero value for J, the
torsion stiffness.
No default (Integer > 0; up to 5 of the unique digits 1-6 with no
embedded blanks)

W1A,W2A,W3A, Components of offset vectors, measured in the displacement


coordinate systems at grid points A and B or in the element
W1B,W2B,W3B coordinate system, from the grid points to the end points of the axis
of shear center. See comment 5.
Default = blank (Real or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

427

Fig 1: Beam element coordinate system.

Fig 2: Direction of Internal Forces and Moments (for C BEAM entry)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

If X1/G0 is a positive integer and X2 and X3 are blank, then G0 is used to orient the
element, otherwise X1, X2, X3 is used.

3.

G0

4.

If there are no pin flags or offsets the continuation may be omitted.

428

GA or GB.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

The OFFT character string specifies how the offset and orientation vector components
are computed. By default, the offset vectors are specified in the Global (local
displacement) coordinate system of each grid A and B, and the orientation vector is
specified in the Global coordinate system of grid A. Using the codes below, the offset
vector can be specified in the element coordinate system and the orientation vector can
be specified in the basic coordinate system. The valid character strings and their
meanings are shown below:
OFFT

Orientation Vector

End A Offset

End B Offset

GGG

Global

Global

Global

BGG

Basic

Global

Global

GGO

Global

Global

Element

BGO

Basic

Global

Element

GOG

Global

Element

Global

BOG

Basic

Element

Global

GOO

Global

Element

Element

BOO

Basic

Element

Element

The element system x-axis is defined from GA to GB. The orientation vector and the
element system x-axis are then used to define the z and y axes of the element system.
A vector is formed from the cross product of a vector going from Grid A to Grid B and the
orientation vector to create the element coordinate z-direction.
6.

Offset vectors are treated like rigid elements. The length of the offset vectors is not
affected by thermal loads.

7.

Torsional stiffness due to warping of the cross-section is not considered.

8.

This card is represented as a bar2 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

429

CBUSH
Bulk Data Entry
CBUSH Bushing Element
Description
Defines a generalized spring-damper structural element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C BUSH

EID

PID

GA

GB

G0/X1

X2

X3

C ID

OC ID

S1

S2

S3

(10)

Example 1

Spring-damper element defined with default orientation and location; default orientation is
only valid when only K1, and/or K4 are defined on referenced PBUSH.
(1)

(2)

(3)

(4)

(5)

C BUSH

(6)

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Example 2

Spring-damper location is offset from mid-point of GA-GB.


(1)

(2)

(3)

(4)

(5)

(6)

C BUSH

19

0.3

430

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Example 3

Spring-damper is oriented by referencing coordinate system 5, and spring-damper location


is explicitly defined using OCID, S1, S2, and S3.
(1)

(2)

(3)

(4)

(5)

C BUSH

41

1.0

0.5

Field

Contents

EID

Element identification number.

(6)

(7)

(8)

(9)

(10)

-0.7

No default (Integer > 0)


PID

Property identification number of a PBUSH entry.


Default = EID (Integer > 0)

GA,GB

Grid point identification number of connection points.


No default (Integer > 0 or <PartName.number>) See comments 6, 9 and
10.

Xi

Components of orientation vector


coordinate system of GA.

, from GA, in the displacement

(Real)

G0

Alternate method to supply vector


is from GA to GO.

using grid point GO. Direction of

is then transferred to End A.

(Integer > 0 or <PartName.number>) See comments 3 and 9.


CID

Element coordinate system identification. A 0 means the basic


coordinate system. If CID is blank, then the element coordinate system
is determined from GO or Xi.
(Integer > 0 or blank) See comments 2 and 3.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

431

Field

Contents

Location of spring-damper as a fraction along the line segment between


GA and GB.
Default = 0.5 (0.0 < Real < 1.0)

OCID

Coordinate system identification for spring-damper offset. See comment


7.
Default = -1 (Integer > -1; -1 indicates that the offset is along GA-GB)

Si

Components of the spring-damper offset in the OCID coordinate system,


ignored if OCID is -1.
(Real)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

C BUSH element

432

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Alternate C BUSH element definition

2.

CID > 0 overrides GO and Xi. Then the element x-axis is along T1, the element y-axis is
along T2, and the element z-axis is along T3 of the CID coordinate system. If the CID
refers to a cylindrical coordinate system or a spherical coordinate system, the grid GA is
used to locate the system. If for cylindrical or spherical coordinate, GA falls on the z-axis
used to define them, it is recommended that another CID be selected to define the
element x-axis.

3.
specified, the line AB is the element x-axis and the orientation vector
plane (similar to the CBEAM element).

lies in the x-y

4.
specified, the line AB is the element x-axis. This option is valid only when K1 or K4 or
both on the PBUSH entry are specified (but K2, K3, K5, and K6 are not specified). If K2,
K3, K5, or K6 are specified, the solver will terminate with an error.
5.

If GA and GB are coincident, or if GB is blank, then CID must be specified.

6.

If OCID refers to a cylindrical or spherical coordinate system, then grid GA is used to


locate the system.

7.

A CBUSH element, referencing a PBUSH property with a single stiffness term, is equivalent
to a CELAS1 or CELAS2 element, only when the elements have zero length. A non-zero
length CBUSH assumes rigid body connections from the connection points, GA and GB, to
the spring-damper location, as defined either by S or the OCID and Si fields.

8.

Bushing elements are ignored in heat transfer analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

433

9.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on CBUSH entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN Bulk Data Entry in the model). number is the identification number of a
referenced local entry in the part PartName. See Parts and Instances in the Users
Guide for detailed information on the use of fully qualified references.

10. The CBUSH element force is calculated as follows:


F = K(UGB - UGA )
Therefore, the sign of the force will depend on the grids GA and GB. If the grids are
switched, then the element force will be reversed.
11. This card is represented as a spring element in HyperMesh.

434

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CBUSH1D
Bulk Data Entry
CBUSH1D Rod-type Spring-Damper Element
Description
Defines a one-dimensional spring-damper structural element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

C BUSH1D

EID

PID

GA

GB

C ID

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C BUSH1D

Field

Contents

EID

Element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Property identification number of a PBUSH1D entry.


Default = EID (Integer > 0)

GA,GB

Grid point identification numbers of connection points.


No default (Integer > 0 or <PartName.number>) See comments 2 and 7.

CID

Element coordinate system identification number. If a value of 0 is input,


the basic coordinate system is selected.
(Integer > 0 or blank) See comments 2 through 4.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

435

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.
axis. In geometric nonlinear analysis, the element axis (line GA to GB) follows the
deformation of grids GA and GB.
3.

If GA and GB are coincident, or if GB is blank, then CID must be specified.

4.

If CID > 0, the x-axis of CID is the element axis. In geometric nonlinear analysis,
depending on the referenced system being movable or fixed, the axis of the element will
move or not move with the axes of the system, respectively. Geometric nonlinear
analysis is selected by an ANALYSIS = NLGEOM, IMPDYN or EXPDYN subcase entry.

5.

In all linear subcases, as well as small displacement nonlinear quasi-static


(ANALYSIS=NLSTAT) subcases, PBUSH1D and CBUSH1D are converted internally to the
equivalent PBUSH (with PBUSHT, if necessary) and CBUSH.

6.

Rod-type spring-damper elements are ignored in heat transfer analysis.

7.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on CBUSH1D entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN bulk data entry in the model). number is the identification number of a referenced
local entry in the part PartName. See Parts and Instances in the Users Guide for
detailed information on the use of fully qualified references.

8.

This card is represented as a spring element in HyperMesh.

436

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CDAMP1
Bulk Data Entry
CDAMP1 Scalar Damper Connection
Description
Defines a scalar damper element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C DAMP1

EID

PID

G1

C1

G2

C2

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

C DAMP1

10

(5)

(6)

(7)

26

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PDAMP property entry.


Default = EID (Integer > 0)

G1, G2

Geometric grid point or scalar point identification number.


Default = 0 (Integer > 0)

C1, C2

Component number in the displacement coordinate system specified by


the CD entry of the GRID data.
Default = 0 (0 < Integer < 6)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

437

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained
to zero.

2.

Scalar points may be used for G1 and/or G2, (with corresponding C1 and/or C2 of zero or
blank). If only scalar points and/or grounded terminals are involved, it is more efficient to
use the CDAMP3 entry.

3.

Element identification numbers must be unique with respect to all other element
identification numbers.

4.

The two connection points (G1, C1) and (G2, C2) must be distinct.

5.

A scalar point specified on this entry need not be defined on an SPOINT entry.

6.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

7.

Scalar damper elements are ignored in heat transfer analysis.

8.

This card is represented as a spring or mass element in HyperMesh.

438

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CDAMP2
Bulk Data Entry
CDAMP2 Scalar Damper Property and Connection
Description
Defines a scalar damper element without reference to a property entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C DAMP2

EID

G1

C1

G2

C2

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C DAMP2

3.12

12

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


B

Value of the scalar damper.


No default (Real)

G1, G2

Geometric grid point identification number.


Default = blank (Integer > 0)

C1, C2

Component number in the displacement coordinate system


specified by the CD entry of the GRID data.
Default = 0 (0 < Integer < 6)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

439

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained
to zero.

2.

Scalar points may be used for G1 and/or G2, (with a corresponding C1 and/or C2 of zero
or blank). If only scalar points and/or grounded terminals are involved, it is more efficient
to use the CDAMP4 entry.

3.

Element identification numbers must be unique with respect to all other element
identification numbers.

4.

This single entry completely defines the element since no material or geometric properties
are required.

5.

The two connection points (G1, C1) and (G2, C2) must be distinct.

6.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

7.

Scalar damper elements are ignored in heat transfer analysis.

8.

This card is represented as a spring or mass element in HyperMesh.

440

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CDAMP3
Bulk Data Entry
CDAMP3 Scalar Damper Connection to Scalar Points Only
Description
Defines a scalar damper element that is connected only to scalar points.
Format
(1)

(2)

(3)

(4)

(5)

C DAMP3

EID

PID

S1

S2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C DAMP3

16

978

24

36

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Property identification number of a PDAMP property entry.


Default = EID (Integer > 0)

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

Comments
1.

S1 or S2, but not both, may be blank or zero, indicating a constrained coordinate.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

441

3.

Only one scalar damper element may be defined on a single entry.

4.

A scalar point specified on this entry need not be defined on an SPOINT entry.

5.

Scalar damper elements are ignored in heat transfer analysis.

6.

This card is represented as a spring or mass element in HyperMesh.

442

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CDAMP4
Bulk Data Entry
CDAMP4 Scalar Damper Property and Connection to Scalar Points Only
Description
Defines a scalar damper element that is connected only to scalar points and is without
reference to a material or property entry.
Format
(1)

(2)

(3)

(4)

(5)

C DAMP4

EID

S1

S2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C DAMP4

16

-2.6

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


B

Scalar damper value.


No default (Real)

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

443

Comments
1.

S1 or S2, but not both, may be blank or zero, indicating a constrained coordinate.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

This single entry completely defines the element since no material or geometric properties
are required.

4.

Only one scalar damper element may be defined on a single entry.

5.

A scalar point specified on this entry need not be defined on an SPOINT entry.

6.

Scalar damper elements are ignored in heat transfer analysis.

7.

This card is represented as a spring or mass element in HyperMesh.

444

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CDSMETH
Bulk Data Entry
CDSMETH - Run Control
Description
The CDSMETH command can be used in the component dynamic synthesis method for
generating component dynamic matrices at each loading frequency.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C DSMETH

C DSID

GTYPE

TF

OSET

TOL

SSF

RSF

C MSOUT

SPID

SPID_F

GP_RC

(10)

Example

(1)

(2)

(3)

(4)

C DSMETH

10

SVDNP

YES

C MSOUT

9000001

9000001

(5)

(6)

(7)

(8)

(10)

YES

Argumen Options
t

Description

CDSID

Identification number of CDSMETH.

<INTEGER>

(9)

Default = NONE

GTYPE

<SVDNP/
BME>
Default =

Altair Engineering

SVDNP:

Dynamic Stiffness Matrix is calculated by singular value


decomposition of transfer function after scaling
rotational DOFs (Comment 6).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

445

Argumen Options
t
SVDNP

TF

Description
BME:

Dynamic Stiffness Matrix is calculated by block matrix


elimination (Comment 6).

Generate transfer functions at the connection and


interior points at each loading frequency.

<YES, NO>
Default = NO

OSET

<INTEGER>
Default = BLANK

TOL

<REAL/BLANK>
Default = 1.0e-20

SSF

<REAL/BLANK>
Default = 1.0

RSF

<REAL/BLANK>
Default = 1.0e-3

CMSOUT

<CMSOUT/BLANK>
Default = BLANK

446

Grid set for interior grids. The responses corresponding


to interior grids may be recovered in the residual run
(Comment 5).

Tolerance value for the Singular Value Decomposition


(SVD) operation that involves pseudoinversion of the
transfer function matrix to obtain the dynamic stiffness
matrix.

Structural scale factor used to scale transfer function


terms associated with the structural degrees of freedom
prior to the singular value decomposition (SVD)
operation.

Rotational scale factor used to scale transfer function


terms associated with the rotational degrees of freedom
prior to the singular value decomposition (SVD)
operation.

This is an optional keyword to specify the creation of


the component model synthesis (CMS) super element
generated using the General Modal method with free
free boundary (Craig-Chang method).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argumen Options
t

Description

SPID

<INTEGER>

The starting SPOINT ID to be used in CMS matrix output


for the structural eigenmodes. There is no default. This
is only valid, if CMSOUT is specified.

SPID_F

<INTEGER>

The starting SPOINT ID to be used in CMS matrix output


for the fluid eigenmodes. There is no default, if fluid
grids are present in the model. However, this must be
used, if there are fluid grids in the model. This is only
valid, if CMSOUT is specified.

GP_RC

<YES, NO>

Grid participation recovery control. If YES, the fluidstructural interface connection matrix is calculated and
stored as a part of the CMS super element. This is only
valid, if CMSOUT is specified.

Default = NO

Comments
1.

The responses available for recovery, and the attachment points available for connection
in the residual structure, must be specified on a BNDFRE1, BNDFREE, CSET or CSET1 data
entry for a modal frequency response analysis in which CDSMETH has been specified.

2.

Frequencies available for recovery must be specified, using the FREQ or FREQ# (# ranges
from 1 to 5) data entries, in the modal frequency response analysis in which CDSMETH
has been specified.

3.

A MODEL card may be used for additional response output for the optional CMS
superelement output.

4.

Reasonable speedup may be achieved by reducing the number of ASET points in the
residual run when CDSMETH is used.

5.

If OSET is specified, TF is automatically set to YES.

6.

Performance may be an issue with the Block Matrix Elimination (BME) method for large
models. The BME option for the GTYPE field is only recommended for small models or when
other methods fail to work.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

447

CELAS1
Bulk Data Entry
CELAS1 Scalar Spring Connection
Description
Defines a scalar spring element of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C ELAS1

EID

PID

G1

C1

G2

C2

(8)

(9)

(10)

Example

(1)

(2)

(3)

C ELAS1

(4)

(5)

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PELAS property entry.


Default = EID (Integer > 0)

G1,G2

Geometric grid point or scalar point identification number.


Default = 0 (Integer > 0)

C1,C2

Component number in the displacement coordinate system specified by


the CD entry of the GRID data.
Default = 0 (0 < Integer < 6)

448

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained
to zero.

2.

Scalar points may be used for G1 and/or G2 (with a corresponding C1 and/or C2 of zero or
blank). If only scalar points and/or grounded terminals are involved, it is more efficient to
use the CELAS3 entry.

3.

Element identification numbers must be unique with respect to all other element
identification numbers.

4.

The two connection points (G1, C1) and (G2, C2) must be distinct.

5.

A scalar point specified on this entry need not be defined on an SPOINT entry.

6.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

7.

A CBUSH element, referencing a PBUSH property with a single stiffness term, is equivalent
to a CELAS1 or CELAS2 element, only when the elements have zero length. A non-zero
length CBUSH assumes rigid body connections from the connection points, GA and GB, to
the spring-damper location, as defined either by S or the OCID and Si fields.

8.

This card is represented as a spring or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

449

CELAS2
Bulk Data Entry
CELAS2 Scalar Spring Property and Connection
Description
Defines a scalar spring element of the structural model without reference to a property entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ELAS2

EID

G1

C1

G2

C2

GE

(10)

Example

(1)

(2)

(3)

C ELAS2

28

6.2+3

(4)

(5)

Field

Contents

EID

Unique element identification number.

(6)

(7)

19

(8)

(9)

(10)

No default (Integer > 0)


K

Spring stiffness.
No default (Real)

G1, G2

Geometric grid point or scalar point identification number.


Default = 0 (Integer > 0)

C1, C2

Component number in the displacement coordinate system specified by


the CD entry of the GRID data.
Default = 0 (0 < Integer < 6)

450

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

GE

Damping coefficient. (See comment 7).


Default = 0.0 (Real)

Stress coefficient.
Default = 0.0 (Real)

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained
to zero.

2.

Scalar points may be used for G1 and/or G2 (with a corresponding C1 and/or C2 of zero or
blank). If only scalar points and/or grounded terminals are involved, it is more efficient to
use the CELAS4 entry.

3.

Element identification numbers must be unique with respect to all other element
identification numbers.

4.

This single entry completely defines the element since no material or geometric properties
are required.

5.

The two connection points (G1, C1) and (G2, C2) must be distinct.

6.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0, by 2.

7.

If PARAM, W4 is not specified, GE is ignored in transient analysis.

8.

A scalar point specified on this entry need not be defined on an SPOINT entry.

9.

The element force of a spring is calculated from the equation: F = k * (u1 u2)
Where, k is the stiffness coefficient for the scalar element and u1 is the displacement of
the first degree-of-freedom listed on the CELAS entry. Element stresses are calculated
from the equation: s = S * F, where, S is the stress coefficient as defined above.

10. When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).
11. A CBUSH element, referencing a PBUSH property with a single stiffness term, is equivalent
to a CELAS1 or CELAS2 element, only when the elements have zero length. A non-zero
length CBUSH assumes rigid body connections from the connection points, GA and GB, to
the spring-damper location, as defined either by S or the OCID and Si fields.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

451

12. This card is represented as a spring or mass element in HyperMesh.

452

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CELAS3
Bulk Data Entry
CELAS3 Scalar Spring Connection to Scalar Points Only
Description
Defines a scalar spring element that connects only to scalar points.
Format
(1)

(2)

(3)

(4)

(5)

C ELAS3

EID

PID

S1

S2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ELAS3

19

14

15

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Property identification number of a PELAS entry.

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

Comments
1.

S1 or S2 may be blank or zero indicating a constrained coordinate.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

Only one scalar spring element may be defined on a single entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

453

4.

A scalar point specified on this entry need not be defined on an SPOINT entry.

5.

This card is represented as a spring or mass element in HyperMesh.

454

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CELAS4
Bulk Data Entry
CELAS4 Scalar Spring Property and Connection to Scalar Points Only
Description
Defines a scalar spring element that is connected only to scalar points without reference to a
property entry.
Format
(1)

(2)

(3)

(4)

(5)

C ELAS4

EID

S1

S2

(6)

(7)

(8)

(9)

GE

(10)

Example

(1)

(2)

(3)

(4)

C ELAS4

42

6.2-3

(5)

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


K

Stiffness of the scalar spring.


No default (Real)

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

GE

Damping coefficient. See comment 7.


Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

455

Field

Contents

Stress coefficient
Default = 0.0 (Real)

Comments
1.

S1 or S2, but not both, may be blank or zero indicating a constrained coordinate.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

This single entry completely defines the element since no material or geometric properties
are required.

4.

Only one scalar spring element may be defined on a single entry.

5.

A scalar point specified on this entry need not be defined on an SPOINT entry.

6.

The element force of a spring is calculated from the equation: F = k * (u1 u2)
Where, k is the stiffness coefficient for the scalar element and u1 is the displacement of
the first degree-of-freedom listed on the CELAS entry. Element stresses are calculated
from the equation: s = S * F, where, S is the stress coefficient as defined above.

7.

If PARAM, W4 is not specified, GE is ignored in transient analysis.

8.

This card is represented as a spring or mass element in HyperMesh.

456

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CFAST
Bulk Data Entry
CFAST Fastener Element Connection
Description
Define a fastener with material orientation connecting two shell surfaces.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C FAST

EID

PID

C TYPE

PIDA/
SHIDA

PIDB/
SHIDB

GS

GA

GB

XS

YS

ZS

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

C FAST

22

PROP

0.2

0.3

0.3

(1)

(2)

(3)

(4)

(5)

(6)

C FAST

22

ELEM

101

201

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

21

30

Example 2

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

457

Field

Contents

PID

Identification number of a PFAST entry.


Default = EID (Integer > 0)

CTYPE

The type of connection between the patches. Either format


connects up to 3 x 3 elements per patch (possibly more for triangular
elements).
For PROP, the connection of surface patch to surface patch is
defined by specifying the property numbers of shells on side A and B,
PIDA and PIDB, respectively.
For ELEM, the connection of surface patch to surface patch is
defined by specifying IDs of shells SHIDA and SHIDB, respectively.
No default

PIDA,PIDB

Property identification numbers of PSHELL entries defining surface A


and B, respectively. Required when CTYPE = PROP.

SHIDA, SHIDB

Element identification numbers of shells defining fastener ends A and


B, respectively. Required when CTYPE = ELEM.

GS

Identification number of a grid point which defines the location of the


connector. See comment 2.
(Integer > 0)

GA, GB

These represent grid identification numbers of piercing points on


surface A and surface B respectively. See comment 3.
(Integer > 0)

XS, YS, ZS

Coordinates of point that defines the location of the fastener in the


basic coordinate system. It is an alternative way of specifying the
location of GS.
(Real)

Comments
1.

458

CFAST defines a flexible connection between two shell surface patches. An internallygenerated CBUSH element will be created automatically for a CFAST, and the end points
of this bushing will be connected to the grids of corresponding shell elements. Then the

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

stiffness, mass and structural damping of the CBUSH will be transferred to the
corresponding shell grids. GS, GA and GB do not hold any independent DOF. See the
figure below:

2.

A CFAST element connects Shell A and Shell B. An internal CBUSH is generated for the
CFAST and supported by fictitious auxiliary points. Auxiliary points, in turn, are
constrained by corresponding shell grids. (To have a clear view, only one of these kind of
constraint relationships is shown with dotted lines).

3.

The end points of the internally-generated CBUSH element are defined from GS, GA, and
GB (not all are required). If GA or GB is not specified, they are generated from the normal
projection of GS onto the surface patches. If GA and GB (or, GA only) are (is) specified,
they take precedence over GS in defining the respective end points (If only GA is
specified, then GA is used as a normal projection point (similar to GS) to generate GB on
Shell B). Also, their locations will be corrected so that they lie on surface patch A and B,
respectively. If neither GS nor GA is specified, then (XS, YS, and ZS), in the basic
coordinate system, must be specified. The length of the connector is the distance
between projected points GA and GB.

4.

The connections of the internally-generated bushing to surface patches A and B are


defined in the following way: the axis GA-GB is used to define four pairs of auxiliary points
GAHi, GBHi, i=1,4 that are located on patches A and B, respectively. The cross-section
area of the resulting hexahedral is equivalent to the area of the connector, defined from
diameter D on PFAST card. The connector stiffness matrix is first built by connecting the
internally-generated bushing element to the auxiliary points, and then constraining them
to supporting shell nodes using respective shape functions. Similarly, the mass of the
fastener is divided by to each side and then distributed via auxiliary points to
supporting shell nodes.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

459

5.

460

Since the geometry for finding the correct projection could be various and complicated,
sometimes the default projection algorithm may fail. However, the default projection rules
and tolerances can be modified to some extent via the SWLDPRM card.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CGAP
Bulk Data Entry
CGAP Gap Element Connection
Description
Defines a gap or friction element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GAP

EID

PID

GA

GB

GO/X1

X2

X3

C ID

(10)

Examples

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C GAP

233

223

3.0

-1.0

1.0

(9)

(10)

Minimum necessary data when GA and GB are not coincident:


C GAP

247

233

223

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

PID

Identification number of a PGAP entry.


Default = EID (Integer > 0)

GA,GB

Connected grid points at ends A and B.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

461

Field

Contents

X1, X2,
X3

Components of the orientation vector, from GA, in the displacement


coordinate system at GA.
Default determined automatically - See comment 7. (Real)

G0

Alternate method to supply orientation vector, using grid point G0. Direction
of orientation vector is from GA to G0.
No default (Integer > 0)

CID

Element coordinate system identification number. CID must be specified if


GA and GB are coincident (distance from GA to GB < 10-4).
Alternatively: FLIP reverses the direction of the gap axis (See comment
5).
Default = blank (Integer > 0 or flip or blank) - See comments 2 through 6.

Comments
1.

For linear subcases, the CGAP element will produce a linear stiffness matrix which remains
linear with the initial stiffness. The stiffness used depends on the value for the initial gap
opening (U0 field in the PGAP entry).

2.

The gap element coordinate system is defined by one of the following methods:
Prescribed CID: If the coordinate system CID is specified, the element coordinate
system is established using that coordinate system. In this case, the element x-axis is
in the coordinate systems 1-direction, and the y-axis is in the coordinate systems 2direction (for rectangular coordinate systems; the 1-direction is the x-direction and
the 2-direction is the y-direction). The orientation vector will be ignored in this case.
CID field blank: If the CID field is blank and the grid points GA and GB are not
coincident (distance from GA to GB > 10-4), then the line GA-GB is the element x-axis
and the orientation vector lies in the x-y plane (as with the CBEAM element).
FLIP option: the x-axis of the gap coordinate system is reversed with respect to the
default orientation described above. This option is useful when meshes of bodies A
and B overlap, rather than have a gap between them (See comment 5).
For gaps with coincident nodes (the distance between GA and GB < 1.0e-4), the gap
coordinate system must be specified.

3.

462

In typical applications, leaving the CID field blank is appropriate when the nodes GA and
GB obstacle are initially separated. If the meshes of bodies A and B overlap, then a
coordinate system CID should be specified or the FLIP option should be used as discussed
below.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

When prescribing the gap coordinate system CID, it is essential to assure that its x-axis
points in the general direction from body A (the one associated with node GA) towards
the body B (the one associated with node GB). This will assure that the gap element
acts to prevent contact/overlap of these bodies. An incorrect orientation of the x-axis
will result in gap elements being ineffective, or will even act to "glue" the bodies together,
rather than prevent them from overlapping. The solver checks for such misalignment and
prints respective error and warning messages. For more information, see the GAPPRM bulk
data card.

5.

The FLIP option in the CID field is useful when meshes of bodies A and B overlap, rather
than have a gap between them. In such cases, the defaults gap axis vector GA-GB
would be opposite to the overall direction from body A to body B and therefore would
produce a "gluing" effect, rather than a resolution of the contact condition. The FLIP
option reverses the default gap direction so that the gap axis correctly points from the
bulk of body A towards body B in such cases. The effect of FLIP is equivalent to defining
a coordinate system with axis 1 pointing in direction GB-GA, rather then GA-GB.
Aside from setting the FLIP option to correctly resolve the cases with initial penetration,
U0 on the PGAP card needs to be properly set to a negative value, or an AUTO option
needs to be used in the U0 field.
Alternatively, FLIP can be used to define a simple cable element. If such an arrangement
is used, then it should be noted that:
a) F0 corresponds to a pair of forces acting on the ends of the cable (pointing inwards),
while U0 corresponds to pre-existing slack or extra length in the cable.
b) Gap open status corresponds to the cable being shortened, while closed gap
status corresponds to the cable being elongated.
c) Positive gap force reported in the results corresponds to the cable being in tension
(note that the force also includes the effect of F0).

6.

The element coordinate system does not rotate as a result of deflections.

7.

If neither coordinate system nor orientation vector are specified, the orientation vector is
defined automatically as a vector aligned with the axis of the basic coordinate system
that makes the largest angle with the gap direction (gap x-axis).

8.

Initial gap openings are specified on the PGAP entry and not derived from the separation
distance between GA and GB.

9.

Forces, which are requested with the FORCE card in the I/O Options or Subcase
Information sections, are output in the element coordinate system. F x is positive for
compression.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

463

C GAP Element C oordinate System

10. For more information on using nonlinear gaps, refer to the Nonlinear Quasi-Static Analysis
section of the User's Guide.
11. Heat transfer properties can be defined for Gap elements using the PGAPHT bulk data
entry.
12. This card is represented as a gap or mass element in HyperMesh.

464

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CGAPG
Bulk Data Entry
CGAPG General Node-to-Obstacle Gap Element
Description
Defines a node-to-obstacle gap element. The obstacle may be an element face or a patch of
nodes.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GAPG

EID

PID

GA

TYP

X1/G0

X2

X3

C ID

GB1/ELIDB

GB2/G1

GB3/G3
or G4

GB4/

GB5

GB6

GB7

GB8

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C GAPG

233

ELEM

3.0

-1.0

1.0

(6)

(7)

(8)

(9)

(10)

(9)

(10)

257

Example 2

(1)

(2)

(3)

(4)

(5)

C GAPG

233

QUAD

110

111

114

113

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

465

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

PID

Identification number of a PGAP entry.


Default = EID (Integer > 0)

GA

Grid point serving as end A of CGAPG.


No default (Integer > 0)

TYP

Character string indicating the type of obstacle on the B end of CGAPG


(opposing node GA):
QUAD indicates that the obstacle is defined as a quadrilateral patch of grid
points. The patch is defined with grid identification numbers GB#.
TRIA indicates that the obstacle is defined as a triangular patch of grid
points. The patch is defined with grid identification numbers GB#.
ELEM indicates that the obstacle is defined as element face.
No default (QUAD, TRIA or ELEM)

X1, X2, X3 Components of the orientation vector, from GA, in the displacement
coordinate system at GA.
Default determined automatically See comment 6. (Real)
G0

Alternate method to supply orientation vector, using grid point G0.


Direction of orientation vector is from GA to G0.
No default (Integer > 0)

CID

Prescribed element coordinate system identification number. CID, when


prescribed, is used to define both the gap axis and orientation vector.
Additional keywords that can be used in this field:
FLIP reverses the default orientation of gap axis, so it points from
obstacle B towards GA.
PUSHOUT for obstacles defined as solid elements using ELIDB, gap axis is
automatically defined so as to create pushout force that prevents GA

466

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
from entering the interior of the element ELIDB.
PUSHNORM gap axis is automatically defined so as to create pushout
force from obstacle B towards GA along the default vector normal to the
obstacle B.
PUSHREVN creates pushout force reversed relative to the PUSHNORM
option.
Default = blank (Integer > 0, FLIP, PUSHOUT, PUSHNORM, PUSHREVN, or
blank). See comments 2 through 5.

GB#

Grid identification number of the grid surface patch on the B (obstacle)


end of the CGAPG element. GB1 to GB3 are required.
No default (Integer > 0). See comment 7.

ELIDB

Element identification number of the element on the B (obstacle) end of


the CGAPG element.
No default (Integer > 0)

G1

For solid element ELIDB: identification number of a grid point connected to


a corner of the face that defines the second end of the CGAPG element.
For PYRA elements, this grid must be on an edge of the quadrilateral face.
Default = blank (Integer > 0 or blank). See comments 8 through 11.

G3

For solid element ELIDB: identification number of a grid point connected to


a corner diagonally opposite to G1 on the same face of a HEXA or PENTA
element. Needed only if G1 has been specified. It is required data for
quadrilateral faces of HEXA and PENTA elements only (Integer or blank).
G3 must be omitted for a triangular surface on a PENTA element and the
quadrilateral face on a PYRA element. For triangular faces of PYRA
elements, this grid must be on the edge next to the quadrilateral face. G1
and G3 must define a positive direction into the element using the right
hand rule.
Default = blank (Integer > 0 or blank). See comments 8 through 11.

G4

For solid element ELIDB: identification number of the TETRA grid point
located at the corner, not on the face being loaded. This is used for
TETRA elements only. It is required data if G1 has been specified.
Default = blank (Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

467

Comments
1.

CGAPG defines a contact element between a point and an obstacle. The obstacle may be
defined as a patch of nodes or as an element face. See figure below:

Typical configuration of C GAPG between node GA and a grid patch GB1GB4.

2.

The gap element coordinate system is defined via one of the following methods:
Prescribed CID: if the coordinate system CID is specified, the element coordinate
system is established using that coordinate system. In this case, the element x-axis is
in the coordinate systems 1-direction, and the y-axis is in the coordinate systems 2direction (for rectangular coordinate systems; the 1-direction is the x-direction and
the 2-direction is the y-direction). The orientation vector will be ignored in this case.
CID field blank: if the CID field is blank and the grid point GA does not lie on the
element face or node patch (distance from GA to the surface > 10-4), then the x-axis
is defined along the shortest distance from GA to the element face or node patch. The
orientation of gap x-axis points from GA towards the patch or element face (see figure
above). The orientation vector defines the x-y plane of the gap coordinate system
(similarly as for the CGAP element).
If the grid point GA lies on the element face or node patch (distance from GA to the
surface < 10-4), then CID must be prescribed.
FLIP option: the x-axis of the gap coordinate system is reversed with respect to the
default orientation described above. This option is useful when meshes of bodies A
and B overlap rather than have a gap between them (See comment 5).
PUSHOUT option: the x-axis of the gap coordinate system is oriented so as to prevent
GA from entering interior of body B. This is only available for obstacles defined as 3D
solid elements with ELIDB.

468

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

With the PUSHNORM option, the gap axis is so oriented so as to produce pushout
force from obstacle B towards GA along the default normal vector to the obstacle
element face or node patch. (Note that this pushout force direction is opposite to the
gap axis, which points from GA towards the obstacle.)
In cases when GA does not have a direct normal projection onto the obstacle B, and
the "shortest distance" projection is used (GAPGPRJ set to SHORT on the GAPPRM
card), the pushout force is oriented along the shortest distance line, yet with the
orientation aligned with the normal vector.
PUSHREVN creates pushout force reversed relative to the PUSHNORM option.
Note that for faces on solid elements, the default normal is pointing inwards, so that it
is the PUSHREVN option that will prevent penetration (PUSHOUT is a more
straightforward option to use on solid faces).
3.

In typical applications, leaving the CID field blank is appropriate when the node GA and
the obstacle are initially separated; that is, there is a gap between respective bodies A
and B (see figure above). If the meshes of bodies A and B overlap, then a coordinate
system CID should be specified (See comment 4). Alternatively, and usually more
intuitively, one of the FLIP, PUSHOUT, PUSHNORM, or PUSHREVN options may be used.

4.

When prescribing the gap coordinate system CID, it is essential to assure that the
resulting gap x-axis points in the general direction from body A (the one associated with
node GA) towards body B (the one associated with element ELIDB or patch GB#). This
assures that the gap element will act to prevent the contact/overlap of these bodies. An
incorrect orientation of the x-axis will result in the gap element being ineffective or can
even act to "glue" the bodies together rather than prevent their overlap. The solver
checks for such misalignment and prints respective error and warning messages. For more
information, see the GAPPRM bulk data card.

5.

The FLIP option in the CID field is useful when the meshes of bodies A and B overlap
rather than have a gap between them. In such cases, the default gap axis vector would
be opposite to the overall direction from body A to body B, and therefore would produce a
"gluing" effect rather than a resolution of the contact condition. The FLIP option reverses
the default gap direction so that the gap axis correctly points from the bulk of body A
towards body B in such cases.
Aside from setting the FLIP option or prescribing CID to correctly resolve the cases with
initial penetration, U0 on the PGAP card needs to be properly set to a negative value or
an AUTO option needs to be used in the U0 field.

6.

If neither coordinate system CID nor orientation vector is specified, the orientation vector
is defined automatically as a vector aligned with the axis of the basic coordinate system
that makes the largest angle with the gap direction (gap x-axis).

7.

GB# are required when TYP is QUAD or TRIA. At least 3, and at most 8, grid IDs may be
specified for GB#. Triangular and quadrilateral element definition sequences apply for the
order of GB# (see below). Missing mid-side nodes are allowed.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

469

Quadrilateral and triangular surface patches as defined when TYP is QUAD or TRIA.

8.

If ELIDB represents a solid element and G1, G3/G4 fields are blank, then the element face
closest to the grid GA is selected as the respective obstacle face.
Note that if the meshes are overlapping (such as in the case of initial penetration), this
option should not be used, and the contact face should be explicitly prescribed.
Otherwise, the face closest to GA may be an internal face within the solid body, rather
than the outside surface of body B.

9.

G1 and G3 are ignored for shell elements (TRIA3, QUAD4, TRIA6 and QUAD8).

10. For triangular faces of PENTA elements, G1 is an identification number of a corner grid
point that is on the face being loaded and the G3 or G4 field is left blank. For faces of
TETRA elements, G1 is an identification number of a corner grid point that is on the face
being loaded and G4 is an identification number of the corner grid point that is not on the
face being loaded. Since a TETRA has only four corner points, this point, G4, is unique
and different for each of the four faces of a TETRA element.
11. For the quadrilateral face of the PYRA element, G1 is an identification number of a corner
grid point on the face and the G3 or G4 field is left blank. For the triangular faces, G1 and
G3 must specify the grids on the edge of the face that borders the quadrilateral face and
the grids must be ordered so that they define an inward normal using the right hand rule.
12. The element coordinate system does not rotate as a result of deformation.
13. Initial gap openings are specified on the PGAP entry and not derived from the separation
distance between GA and GB, unless the AUTO option is used on the PGAP card.
14. Gap forces, which are requested with the FORCE card in the I/O Options or Subcase
Information sections, are output in the gap element coordinate system. F x is positive for
compression.
15. For linear subcases, the CGAPG element will produce a linear stiffness matrix which
remains linear with the initial stiffness. The stiffness used depends on the value for the
initial gap opening (U0 field in the PGAP entry).
16. For more information on using nonlinear gaps, refer to the Nonlinear Quasi-Static Analysis
section of the User's Guide.

470

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

17. This card is represented as a gap or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

471

CGASK6
Bulk Data Entry
CGASK6 Five-sided Solid Gasket Element with Six Grid Nodes
Description
Defining the connections of the GASK6 solid gasket element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK6

EID

PID

G1

G2

G3

G4

G5

G6

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK6

71

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PGASK property entry.


Default = EID (Integer > 0)

G#

Grid point identification number of connection points.


No default (Integer > 0)

Comments
1.

472

Element identification numbers must be unique with respect to all other element
identification numbers.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

Grid points G1, , G3 must be given in consecutive order at the bottom face of the
gasket element. G4, , G6 must be on the top face with G4 opposite G1, G5 opposite G2,
and so on.

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G4 with G6. In such cases, the element local coordinate system will be built on
the renumbered node sequence.

4.

The element coordinate system for the CGASK6 element is defined below.
The local 3-direction (the gasket material thickness direction in default) is defined as the
simple average of the unit normal directions on the top and bottom surfaces of the
element. After the local 3-direction is defined, a local 1-2 plane is generated accordingly.
Then, the local 1-direction and 2-direction are defined as follows: Project the basic x-axis
onto the local 1-2 plane, and set it to be the default local 1-direction. If the basic x-axis
is within 0.1 difference as the local 3-direction, project the basic z-axis onto the local 12 plane and set it to be the local 1-direction. The local 2-direction is determined then.

5.

The gasket material coordinate system is the same as the element coordinate system in
default and can be defined as a prescribed system through PGASK entry.

6.

This card is represented as a gask6 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

473

CGASK8
Bulk Data Entry
CGASK8 Six-sided Solid Gasket Element with Eight Grid Nodes
Description
Defining the connections of the GASK8 solid gasket element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK8

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK8

71

10

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PGASK property entry.


Default = EID (Integer > 0)

G#

Grid point identification number of connection points.


No default (Integer > 0)

474

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Grid points G1, , G4 must be given in consecutive order at the bottom face of the
gasket element. G5, , G8 must be on the top face with G5 opposite G1, G6 opposite G2,
and so on.

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G5 with G7. In such cases, the element local coordinate system will be built on
the renumbered node sequence.

4.

The element coordinate system for the CGASK8 element is defined below.
The local 3-direction (the gasket material thickness direction in default) is defined as the
simple average of the unit normal directions on the top and bottom surfaces of the
element. After the local 3-direction is defined, a local 1-2 plane is generated accordingly.
Then, the local 1-direction and 2-direction are defined as follows: Project the basic x-axis
onto the local 1-2 plane, and set it to be the default local 1-direction. If the basic x-axis
is within 0.1 difference as the local 3-direction, project the basic z-axis onto the local 12 plane and set it to be the local 1-direction. The local 2-direction is determined then.

5.

The gasket material coordinate system is the same as the element coordinate system in
default and can be defined as a prescribed system through PGASK entry.

6.

This card is represented as a gask8 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

475

CGASK12
Bulk Data Entry
CGASK12 Five-sided Solid Gasket Element with Twelve Grid Nodes
Description
Defining the connections of the GASK12 solid gasket element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK12

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK12

71

10

11

12

13

14

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PGASK property entry.


Default = EID (Integer > 0)

G#

Grid point identification number of connection points.


No default (Integer > 0)

476

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Corner grid points G1, , G3 must be given in consecutive order at the bottom face of the
gasket element. Corner grid points G4, , G6 must be on the top face with G4 opposite
G1, G5 opposite G2, and so on.
Edge grid points G7, , G9 must be given in consecutive order at the bottom face of the
gasket element. Edge grid points G10, , G12 must be on the top face with G10 opposite
G7, G11 opposite G8, and so on.

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G4 with G6. In such cases, the element local coordinate system will be built on
the renumbered node sequence.

4.

The element coordinate system for the CGASK12 element is defined below.
The local 3-direction (the gasket material thickness direction in default) is defined as the
simple average of the unit normal directions on the top and bottom surfaces of the
element. After the local 3-direction is defined, a local 1-2 plane is generated accordingly.
Then, the local 1-direction and 2-direction are defined as follows: Project the basic x-axis
onto the local 1-2 plane, and set it to be the default local 1-direction. If the basic x-axis
is within 0.1 difference as the local 3-direction, project the basic z-axis onto the local 12 plane and set it to be the local 1-direction. The local 2-direction is determined then.

5.

The gasket material coordinate system is the same as the element coordinate system in
default and can be defined as a prescribed system through PGASK entry.

6.

This card is represented as a gask12 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

477

CGASK16
Bulk Data Entry
CGASK16 Six-sided Solid Gasket Element with Sixteen Grid Nodes
Description
Defining the connections of the GASK16 solid gasket element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK16

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

G13

G14

G15

G16

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C GASK16

71

10

11

12

13

14

15

16

17

18

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PGASK property entry.


Default = EID (Integer > 0)

478

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

G#

Grid point identification number of connection points.


No default (Integer > 0)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Corner grid points G1, , G4 must be given in consecutive order at the bottom face of the
gasket element. Corner grid points G5, , G8 must be on the top face with G5 opposite
G1, G6 opposite G2, and so on.
Edge grid points G9, , G12 must be given in consecutive order at the bottom face of the
gasket element. Edge grid points G13, , G16 must be on the top face with G13 opposite
G9, G14 opposite G10, and so on.

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G5 with G7. In such cases, the element local coordinate system will be built on
the renumbered node sequence.

4.

The element coordinate system for the CGASK16 element is defined below.
The local 3-direction (the gasket material thickness direction in default) is defined as the
simple average of the unit normal directions on the top and bottom surfaces of the
element. After the local 3-direction is defined, a local 1-2 plane is generated accordingly.
Then, the local 1-direction and 2-direction are defined as follows: Project the basic x-axis
onto the local 1-2 plane, and set it to be the default local 1-direction. If the basic x-axis
is within 0.1 difference as the local 3-direction, project the basic z-axis onto the local 12 plane and set it to be the local 1-direction. The local 2-direction is determined then.

5.

The gasket material coordinate system is the same as the element coordinate system in
default and can be defined as a prescribed system through PGASK entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

479

6.

480

This card is represented as a gask16 element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHACAB
Bulk Data Entry
CHACAB Six-sided, Frequency-dependent Structural Acoustic Absorber Element
Description
Defines the frequency-dependent structural acoustic absorber element in coupled fluidstructural analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C HAC AB

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

G17

G18

G19

G20

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C HAC AB

71

10

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PACABS property entry.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

481

Field

Contents

Gi

Grid point identification numbers of connection points.


Default = blank (Integer > 0 or blank)

Input File - chacab.fem


$$------------------------------------------------------------------------------$
$$
$
$$ NASTRAN Input Deck Generated by HyperMesh Version : 8.0SR1
$
$$ Generated using HyperMesh-Nastran Template Version : 8.0sr1
$$
$
$$
Template: general
$
$$
$
$$------------------------------------------------------------------------------$
$$------------------------------------------------------------------------------$
$$
Executive Control Cards
$
$$------------------------------------------------------------------------------$
SOL 111
CEND
$$------------------------------------------------------------------------------$
$$
Case Control Cards
$
$$------------------------------------------------------------------------------$
SET 1 = 1734
DISPLACEMENT = 1
$
$HMNAME LOADSTEP
1"Load2"
SUBCASE
1
LABEL=
Load2
SPC =
4
FREQUENCY =
5
DLOAD =
2
$$------------------------------------------------------------------------------$
$$
Bulk Data Cards
$
$$------------------------------------------------------------------------------$
BEGIN BULK
$CHEXA
1056
2
1650
1661
1662
$+
1683
1672
CHACAB
1056
100
1650
1645
1657
+
1671
1672
PACABS,100,YES,1,2,3,1.5,10.0,2.0
PARAM,G,0.001
PARAM,COUPMASS,-1
PARAM,POST,-1
$ACMODL
DIFF
0.1
$$
EIGRL,20,,,300
EIGRL,21,,,300
$$ GRID Data
$$
GRID
1
2.0
2.0
0.0
GRID
2
2.0
1.5
0.0
GRID
3
2.0
1.0
0.0
GRID
4
2.0
0.5
0.0
GRID
5
2.0
0.0
0.0
GRID
6
2.0
-0.5
0.0
GRID
7
2.0
-1.0
0.0
GRID
8
2.0
-1.5
0.0
GRID
9
2.0
-2.0
0.0

482

1651
1658

1671
1676

1682+
1675+

-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78

Altair Engineering

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0

2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

483

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

484

79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752

-2.0
-2.0
-2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
1.5
1.5
1.0
1.0
0.5
0.5
0.0
0.0
-0.5
-0.5
-1.0
-1.0
-1.5
-1.5
-2.0
-2.0
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
1.5
1.5
1.5
1.5

-1.0
0.0
-1.5
0.0
-2.0
0.0
2.0
0.0
1.5
0.0
1.0
0.0
0.5
0.0
0.0
0.0
-0.5
0.0
-1.0
0.0
-1.5
0.0
-2.0
0.0
2.0
0.0
1.5
0.0
1.0
0.0
0.5
0.0
0.0
0.0
-0.5
0.0
-1.0
0.0
-1.5
0.0
-2.0
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
0.0
-2.5
0.0
2.5
1.0
2.0
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.5
1.0
1.0
1.0
1.0
1.0
0.5
1.0
0.5
1.0
-4.2E-191.0
-6.5E-201.0
-0.5
1.0
-0.5
1.0
-1.0
1.0
-1.0
1.0
-1.5
1.0
-1.5
1.0
-2.0
1.0
-2.0
1.0
-2.5
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821

Altair Engineering

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5

0.5
1.0
-9.8E-211.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-1.5E-211.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-2.3E-221.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-3.5E-231.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-5.3E-241.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-8.1E-251.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-9.3E-181.0
-0.5
1.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

485

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

486

822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890

-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-2.0E-181.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-1.0E-181.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.5
2.0
2.0
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.5
2.0
1.0
2.0
1.0
2.0
0.5
2.0
0.5
2.0
-6.0E-192.0
-1.2E-192.0
-0.5
2.0
-0.5
2.0
-1.0
2.0
-1.0
2.0
-1.5
2.0
-1.5
2.0
-2.0
2.0
-2.0
2.0
-2.5
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-2.1E-202.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-3.8E-212.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959

Altair Engineering

1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5

-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-6.7E-222.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-1.2E-222.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-2.0E-232.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-1.4E-182.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-1.3E-172.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-4.1E-182.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

487

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

488

960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028

-2.5
1.5
2.0
-2.5
1.0
2.0
-2.5
0.5
2.0
-2.5
-2.5E-182.0
-2.5
-0.5
2.0
-2.5
-1.0
2.0
-2.5
-1.5
2.0
-2.5
-2.0
2.0
-2.5
-2.5
2.0
2.5
2.5
3.0
2.5
2.0
3.0
2.0
2.0
3.0
2.0
2.5
3.0
2.5
1.5
3.0
2.0
1.5
3.0
2.5
1.0
3.0
2.0
1.0
3.0
2.5
0.5
3.0
2.0
0.5
3.0
2.5
-6.7E-193.0
2.0
-1.5E-193.0
2.5
-0.5
3.0
2.0
-0.5
3.0
2.5
-1.0
3.0
2.0
-1.0
3.0
2.5
-1.5
3.0
2.0
-1.5
3.0
2.5
-2.0
3.0
2.0
-2.0
3.0
2.5
-2.5
3.0
2.0
-2.5
3.0
1.5
2.0
3.0
1.5
2.5
3.0
1.5
1.5
3.0
1.5
1.0
3.0
1.5
0.5
3.0
1.5
-3.1E-203.0
1.5
-0.5
3.0
1.5
-1.0
3.0
1.5
-1.5
3.0
1.5
-2.0
3.0
1.5
-2.5
3.0
1.0
2.0
3.0
1.0
2.5
3.0
1.0
1.5
3.0
1.0
1.0
3.0
1.0
0.5
3.0
1.0
-6.2E-213.0
1.0
-0.5
3.0
1.0
-1.0
3.0
1.0
-1.5
3.0
1.0
-2.0
3.0
1.0
-2.5
3.0
0.5
2.0
3.0
0.5
2.5
3.0
0.5
1.5
3.0
0.5
1.0
3.0
0.5
0.5
3.0
0.5
-1.2E-213.0
0.5
-0.5
3.0
0.5
-1.0
3.0
0.5
-1.5
3.0
0.5
-2.0
3.0
0.5
-2.5
3.0
1.50E-322.0
3.0
3.80E-332.5
3.0
2.67E-331.5
3.0
4.07E-341.0
3.0
6.20E-350.5
3.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097

Altair Engineering

6.35E-32-2.3E-223.0
1.29E-31-0.5
3.0
-4.0E-32-1.0
3.0
-5.5E-32-1.5
3.0
-3.2E-32-2.0
3.0
-4.8E-33-2.5
3.0
-0.5
2.0
3.0
-0.5
2.5
3.0
-0.5
1.5
3.0
-0.5
1.0
3.0
-0.5
0.5
3.0
-0.5
-2.2E-193.0
-0.5
-0.5
3.0
-0.5
-1.0
3.0
-0.5
-1.5
3.0
-0.5
-2.0
3.0
-0.5
-2.5
3.0
-1.0
2.0
3.0
-1.0
2.5
3.0
-1.0
1.5
3.0
-1.0
1.0
3.0
-1.0
0.5
3.0
-1.0
-2.6E-183.0
-1.0
-0.5
3.0
-1.0
-1.0
3.0
-1.0
-1.5
3.0
-1.0
-2.0
3.0
-1.0
-2.5
3.0
-1.5
2.0
3.0
-1.5
2.5
3.0
-1.5
1.5
3.0
-1.5
1.0
3.0
-1.5
0.5
3.0
-1.5
-1.5E-173.0
-1.5
-0.5
3.0
-1.5
-1.0
3.0
-1.5
-1.5
3.0
-1.5
-2.0
3.0
-1.5
-2.5
3.0
-2.0
2.0
3.0
-2.0
2.5
3.0
-2.0
1.5
3.0
-2.0
1.0
3.0
-2.0
0.5
3.0
-2.0
-5.3E-183.0
-2.0
-0.5
3.0
-2.0
-1.0
3.0
-2.0
-1.5
3.0
-2.0
-2.0
3.0
-2.0
-2.5
3.0
-2.5
2.0
3.0
-2.5
2.5
3.0
-2.5
1.5
3.0
-2.5
1.0
3.0
-2.5
0.5
3.0
-2.5
-3.3E-183.0
-2.5
-0.5
3.0
-2.5
-1.0
3.0
-2.5
-1.5
3.0
-2.5
-2.0
3.0
-2.5
-2.5
3.0
2.5
2.5
4.0
2.5
2.0
4.0
2.0
2.0
4.0
2.0
2.5
4.0
2.5
1.5
4.0
2.0
1.5
4.0
2.5
1.0
4.0
2.0
1.0
4.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

489

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

490

1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166

2.5
0.5
4.0
2.0
0.5
4.0
2.5
-1.0E-164.0
2.0
-1.8E-164.0
2.5
-0.5
4.0
2.0
-0.5
4.0
2.5
-1.0
4.0
2.0
-1.0
4.0
2.5
-1.5
4.0
2.0
-1.5
4.0
2.5
-2.0
4.0
2.0
-2.0
4.0
2.5
-2.5
4.0
2.0
-2.5
4.0
1.5
2.0
4.0
1.5
2.5
4.0
1.5
1.5
4.0
1.5
1.0
4.0
1.5
0.5
4.0
1.5
-3.1E-164.0
1.5
-0.5
4.0
1.5
-1.0
4.0
1.5
-1.5
4.0
1.5
-2.0
4.0
1.5
-2.5
4.0
1.0
2.0
4.0
1.0
2.5
4.0
1.0
1.5
4.0
1.0
1.0
4.0
1.0
0.5
4.0
1.0
-3.6E-164.0
1.0
-0.5
4.0
1.0
-1.0
4.0
1.0
-1.5
4.0
1.0
-2.0
4.0
1.0
-2.5
4.0
0.5
2.0
4.0
0.5
2.5
4.0
0.5
1.5
4.0
0.5
1.0
4.0
0.5
0.5
4.0
0.5
-2.8E-164.0
0.5
-0.5
4.0
0.5
-1.0
4.0
0.5
-1.5
4.0
0.5
-2.0
4.0
0.5
-2.5
4.0
-1.7E-162.0
4.0
-2.3E-162.5
4.0
-2.7E-171.5
4.0
-3.0E-171.0
4.0
-7.0E-170.5
4.0
2.16E-17-1.4E-164.0
1.65E-16-0.5
4.0
3.53E-16-1.0
4.0
2.86E-16-1.5
4.0
-5.5E-17-2.0
4.0
-2.5E-16-2.5
4.0
-0.5
2.0
4.0
-0.5
2.5
4.0
-0.5
1.5
4.0
-0.5
1.0
4.0
-0.5
0.5
4.0
-0.5
-2.5E-174.0
-0.5
-0.5
4.0
-0.5
-1.0
4.0
-0.5
-1.5
4.0
-0.5
-2.0
4.0
-0.5
-2.5
4.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235

Altair Engineering

-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
1.5
1.5
1.5

2.0
4.0
2.5
4.0
1.5
4.0
1.0
4.0
0.5
4.0
9.63E-174.0
-0.5
4.0
-1.0
4.0
-1.5
4.0
-2.0
4.0
-2.5
4.0
2.0
4.0
2.5
4.0
1.5
4.0
1.0
4.0
0.5
4.0
2.14E-164.0
-0.5
4.0
-1.0
4.0
-1.5
4.0
-2.0
4.0
-2.5
4.0
2.0
4.0
2.5
4.0
1.5
4.0
1.0
4.0
0.5
4.0
1.84E-164.0
-0.5
4.0
-1.0
4.0
-1.5
4.0
-2.0
4.0
-2.5
4.0
2.0
4.0
2.5
4.0
1.5
4.0
1.0
4.0
0.5
4.0
1.10E-164.0
-0.5
4.0
-1.0
4.0
-1.5
4.0
-2.0
4.0
-2.5
4.0
2.5
5.0
2.0
5.0
2.0
5.0
2.5
5.0
1.5
5.0
1.5
5.0
1.0
5.0
1.0
5.0
0.5
5.0
0.5
5.0
-1.8E-165.0
-2.4E-165.0
-0.5
5.0
-0.5
5.0
-1.0
5.0
-1.0
5.0
-1.5
5.0
-1.5
5.0
-2.0
5.0
-2.0
5.0
-2.5
5.0
-2.5
5.0
2.0
5.0
2.5
5.0
1.5
5.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

491

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

492

1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304

1.5
1.0
5.0
1.5
0.5
5.0
1.5
-2.8E-165.0
1.5
-0.5
5.0
1.5
-1.0
5.0
1.5
-1.5
5.0
1.5
-2.0
5.0
1.5
-2.5
5.0
1.0
2.0
5.0
1.0
2.5
5.0
1.0
1.5
5.0
1.0
1.0
5.0
1.0
0.5
5.0
1.0
-3.0E-165.0
1.0
-0.5
5.0
1.0
-1.0
5.0
1.0
-1.5
5.0
1.0
-2.0
5.0
1.0
-2.5
5.0
0.5
2.0
5.0
0.5
2.5
5.0
0.5
1.5
5.0
0.5
1.0
5.0
0.5
0.5
5.0
0.5
-2.4E-165.0
0.5
-0.5
5.0
0.5
-1.0
5.0
0.5
-1.5
5.0
0.5
-2.0
5.0
0.5
-2.5
5.0
-2.4E-162.0
5.0
-2.4E-162.5
5.0
-1.4E-161.5
5.0
-1.1E-161.0
5.0
-6.8E-170.5
5.0
-2.1E-17-1.4E-165.0
1.13E-16-0.5
5.0
2.64E-16-1.0
5.0
2.07E-16-1.5
5.0
-8.9E-18-2.0
5.0
-1.0E-16-2.5
5.0
-0.5
2.0
5.0
-0.5
2.5
5.0
-0.5
1.5
5.0
-0.5
1.0
5.0
-0.5
0.5
5.0
-0.5
-2.9E-175.0
-0.5
-0.5
5.0
-0.5
-1.0
5.0
-0.5
-1.5
5.0
-0.5
-2.0
5.0
-0.5
-2.5
5.0
-1.0
2.0
5.0
-1.0
2.5
5.0
-1.0
1.5
5.0
-1.0
1.0
5.0
-1.0
0.5
5.0
-1.0
8.84E-175.0
-1.0
-0.5
5.0
-1.0
-1.0
5.0
-1.0
-1.5
5.0
-1.0
-2.0
5.0
-1.0
-2.5
5.0
-1.5
2.0
5.0
-1.5
2.5
5.0
-1.5
1.5
5.0
-1.5
1.0
5.0
-1.5
0.5
5.0
-1.5
1.34E-165.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373

Altair Engineering

-1.5
-0.5
5.0
-1.5
-1.0
5.0
-1.5
-1.5
5.0
-1.5
-2.0
5.0
-1.5
-2.5
5.0
-2.0
2.0
5.0
-2.0
2.5
5.0
-2.0
1.5
5.0
-2.0
1.0
5.0
-2.0
0.5
5.0
-2.0
1.09E-165.0
-2.0
-0.5
5.0
-2.0
-1.0
5.0
-2.0
-1.5
5.0
-2.0
-2.0
5.0
-2.0
-2.5
5.0
-2.5
2.0
5.0
-2.5
2.5
5.0
-2.5
1.5
5.0
-2.5
1.0
5.0
-2.5
0.5
5.0
-2.5
5.75E-175.0
-2.5
-0.5
5.0
-2.5
-1.0
5.0
-2.5
-1.5
5.0
-2.5
-2.0
5.0
-2.5
-2.5
5.0
2.0
2.0
0.0
2.0
1.5
0.0
2.0
1.0
0.0
2.0
0.5
0.0
2.0
-2.2E-180.0
2.0
-0.5
0.0
2.0
-1.0
0.0
2.0
-1.5
0.0
2.0
-2.0
0.0
1.5
2.0
0.0
1.5
1.5
0.0
1.5
1.0
0.0
1.5
0.5
0.0
1.5
-1.9E-180.0
1.5
-0.5
0.0
1.5
-1.0
0.0
1.5
-1.5
0.0
1.5
-2.0
0.0
1.0
2.0
0.0
1.0
1.5
0.0
1.0
1.0
0.0
1.0
0.5
0.0
1.0
-1.9E-180.0
1.0
-0.5
0.0
1.0
-1.0
0.0
1.0
-1.5
0.0
1.0
-2.0
0.0
0.5
2.0
0.0
0.5
1.5
0.0
0.5
1.0
0.0
0.5
0.5
0.0
0.5
-1.9E-180.0
0.5
-0.5
0.0
0.5
-1.0
0.0
0.5
-1.5
0.0
0.5
-2.0
0.0
-2.8E-182.0
0.0
-2.8E-181.5
0.0
-2.5E-181.0
0.0
-2.8E-180.5
0.0
-3.1E-18-1.7E-180.0
-2.8E-18-0.5
0.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

493

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

494

1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442

-3.1E-18-1.0
0.0
-1.9E-18-1.5
0.0
-2.8E-18-2.0
0.0
-0.5
2.0
0.0
-0.5
1.5
0.0
-0.5
1.0
0.0
-0.5
0.5
0.0
-0.5
-1.7E-180.0
-0.5
-0.5
0.0
-0.5
-1.0
0.0
-0.5
-1.5
0.0
-0.5
-2.0
0.0
-1.0
2.0
0.0
-1.0
1.5
0.0
-1.0
1.0
0.0
-1.0
0.5
0.0
-1.0
-1.9E-180.0
-1.0
-0.5
0.0
-1.0
-1.0
0.0
-1.0
-1.5
0.0
-1.0
-2.0
0.0
-1.5
2.0
0.0
-1.5
1.5
0.0
-1.5
1.0
0.0
-1.5
0.5
0.0
-1.5
-1.7E-180.0
-1.5
-0.5
0.0
-1.5
-1.0
0.0
-1.5
-1.5
0.0
-1.5
-2.0
0.0
-2.0
2.0
0.0
-2.0
1.5
0.0
-2.0
1.0
0.0
-2.0
0.5
0.0
-2.0
-2.2E-180.0
-2.0
-0.5
0.0
-2.0
-1.0
0.0
-2.0
-1.5
0.0
-2.0
-2.0
0.0
2.4964642.0
0.004472
2.4964641.5
0.004472
2.4964641.0
0.004472
2.4964640.5
0.004472
2.496464-2.6E-180.004472
2.496464-0.5
0.004472
2.496464-1.0
0.004472
2.496464-1.5
0.004472
2.496464-2.0
0.004472
-2.496462.0
0.004472
-2.496461.5
0.004472
-2.496461.0
0.004472
-2.496460.5
0.004472
-2.49646-2.6E-180.004472
-2.49646-0.5
0.004472
-2.49646-1.0
0.004472
-2.49646-1.5
0.004472
-2.49646-2.0
0.004472
2.4961522.4961520.005963
2.496152-2.496150.005963
2.0
2.4964640.004472
2.0
-2.496460.004472
1.5
2.4964640.004472
1.5
-2.496460.004472
1.0
2.4964640.004472
1.0
-2.496460.004472
0.5
2.4964640.004472
0.5
-2.496460.004472
-2.6E-182.4964640.004472
-2.6E-18-2.496460.004472

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1493
1494
1495
1496
1497
1498
1499
1500
1504
1505
1506
1507
1508
1509
1510
1511
1515
1516
1517
1518
1519
1520

Altair Engineering

-0.5
2.4964640.004472
-0.5
-2.496460.004472
-1.0
2.4964640.004472
-1.0
-2.496460.004472
-1.5
2.4964640.004472
-1.5
-2.496460.004472
-2.0
2.4964640.004472
-2.0
-2.496460.004472
-2.496152.4961520.005963
-2.49615-2.496150.005963
-2.49615-2.496154.994037
-2.49646-2.0
4.995528
-2.49646-1.5
4.995528
-2.49646-1.0
4.995528
-2.49646-0.5
4.995528
-2.496465.58E-174.995528
-2.496460.5
4.995528
-2.496461.0
4.995528
-2.496461.5
4.995528
-2.496152.4961524.994037
-2.496462.0
4.995528
-2.0
-2.496464.995528
-2.0
-2.0
5.0
-2.0
-1.5
5.0
-2.0
-1.0
5.0
-2.0
-0.5
5.0
-2.0
1.05E-165.0
-2.0
0.5
5.0
-2.0
1.0
5.0
-2.0
1.5
5.0
-2.0
2.4964644.995528
-2.0
2.0
5.0
-1.5
-2.496464.995528
-1.5
-2.0
5.0
-1.5
-1.5
5.0
-1.5
-1.0
5.0
-1.5
-0.5
5.0
-1.5
1.32E-165.0
-1.5
0.5
5.0
-1.5
1.0
5.0
-1.5
1.5
5.0
-1.5
2.4964644.995528
-1.5
2.0
5.0
-1.0
-2.496464.995528
-1.0
-2.0
5.0
-1.0
-1.5
5.0
-1.0
-1.0
5.0
-1.0
1.0
5.0
-1.0
1.5
5.0
-1.0
2.4964644.995528
-1.0
2.0
5.0
-0.5
-2.496464.995528
-0.5
-2.0
5.0
-0.5
-1.5
5.0
-0.5
-1.0
5.0
-0.5
1.0
5.0
-0.5
1.5
5.0
-0.5
2.4964644.995528
-0.5
2.0
5.0
-1.0E-16-2.496464.995528
-1.1E-17-2.0
5.0
2.04E-16-1.5
5.0
2.61E-16-1.0
5.0
-1.2E-161.0
5.0
-1.4E-161.5
5.0
-2.4E-162.4964644.995528
-2.4E-162.0
5.0
0.5
-2.496464.995528
0.5
-2.0
5.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

495

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

496

1521
1522
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592

0.5
-1.5
5.0
0.5
-1.0
5.0
0.5
1.0
5.0
0.5
1.5
5.0
0.5
2.4964644.995528
0.5
2.0
5.0
1.0
-2.496464.995528
1.0
-2.0
5.0
1.0
-1.5
5.0
1.0
-1.0
5.0
1.0
-0.5
5.0
1.0
-3.0E-165.0
1.0
0.5
5.0
1.0
1.0
5.0
1.0
1.5
5.0
1.0
2.4964644.995528
1.0
2.0
5.0
1.5
-2.496464.995528
1.5
-2.0
5.0
1.5
-1.5
5.0
1.5
-1.0
5.0
1.5
-0.5
5.0
1.5
-2.8E-165.0
1.5
0.5
5.0
1.5
1.0
5.0
1.5
1.5
5.0
1.5
2.4964644.995528
1.5
2.0
5.0
2.0
-2.496464.995528
2.496152-2.496154.994037
2.0
-2.0
5.0
2.496464-2.0
4.995528
2.0
-1.5
5.0
2.496464-1.5
4.995528
2.0
-1.0
5.0
2.496464-1.0
4.995528
2.0
-0.5
5.0
2.496464-0.5
4.995528
2.0
-2.4E-165.0
2.496464-1.8E-164.995528
2.0
0.5
5.0
2.4964640.5
4.995528
2.0
1.0
5.0
2.4964641.0
4.995528
2.0
1.5
5.0
2.4964641.5
4.995528
2.0
2.4964644.995528
2.0
2.0
5.0
2.4964642.0
4.995528
2.4961522.4961524.994037
-2.49776-2.497764.0
-2.5
-2.0
4.0
-2.5
-1.5
4.0
-2.5
-1.0
4.0
-2.5
-0.5
4.0
-2.5
1.07E-164.0
-2.5
0.5
4.0
-2.5
1.0
4.0
-2.5
1.5
4.0
-2.497762.4977644.0
-2.5
2.0
4.0
-2.0
-2.5
4.0
-2.0
2.5
4.0
-1.5
-2.5
4.0
-1.5
2.5
4.0
-1.0
-2.5
4.0
-1.0
2.5
4.0
-0.5
-2.5
4.0
-0.5
2.5
4.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661

Altair Engineering

-2.5E-16-2.5
4.0
-2.3E-162.5
4.0
0.5
-2.5
4.0
0.5
2.5
4.0
1.0
-2.5
4.0
1.0
2.5
4.0
1.5
-2.5
4.0
1.5
2.5
4.0
2.0
-2.5
4.0
2.497764-2.497764.0
2.5
-2.0
4.0
2.5
-1.5
4.0
2.5
-1.0
4.0
2.5
-0.5
4.0
2.5
-1.0E-164.0
2.5
0.5
4.0
2.5
1.0
4.0
2.5
1.5
4.0
2.0
2.5
4.0
2.5
2.0
4.0
2.4977642.4977644.0
-2.49776-2.497763.0
-2.5
-2.0
3.0
-2.5
-1.5
3.0
-2.5
-1.0
3.0
-2.5
-0.5
3.0
-2.5
-5.4E-183.0
-2.5
0.5
3.0
-2.5
1.0
3.0
-2.5
1.5
3.0
-2.497762.4977643.0
-2.5
2.0
3.0
-2.0
-2.5
3.0
-2.0
2.5
3.0
-1.5
-2.5
3.0
-1.5
2.5
3.0
-1.0
-2.5
3.0
-1.0
2.5
3.0
-0.5
-2.5
3.0
-0.5
2.5
3.0
-2.9E-18-2.5
3.0
-3.1E-182.5
3.0
0.5
-2.5
3.0
0.5
2.5
3.0
1.0
-2.5
3.0
1.0
2.5
3.0
1.5
-2.5
3.0
1.5
2.5
3.0
2.0
-2.5
3.0
2.497764-2.497763.0
2.5
-2.0
3.0
2.5
-1.5
3.0
2.5
-1.0
3.0
2.5
-0.5
3.0
2.5
-3.4E-183.0
2.5
0.5
3.0
2.5
1.0
3.0
2.5
1.5
3.0
2.0
2.5
3.0
2.5
2.0
3.0
2.4977642.4977643.0
-2.49776-2.497762.0
-2.5
-2.0
2.0
-2.5
-1.5
2.0
-2.5
-1.0
2.0
-2.5
-0.5
2.0
-2.5
-5.0E-182.0
-2.5
0.5
2.0
-2.5
1.0
2.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

497

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

498

1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730

-2.5
1.5
2.0
-2.497762.4977642.0
-2.5
2.0
2.0
-2.0
-2.5
2.0
-2.0
2.5
2.0
-1.5
-2.5
2.0
-1.5
2.5
2.0
-1.0
-2.5
2.0
-1.0
2.5
2.0
-0.5
-2.5
2.0
-0.5
2.5
2.0
-2.5E-18-2.5
2.0
-2.5E-182.5
2.0
0.5
-2.5
2.0
0.5
2.5
2.0
1.0
-2.5
2.0
1.0
2.5
2.0
1.5
-2.5
2.0
1.5
2.5
2.0
2.0
-2.5
2.0
2.497764-2.497762.0
2.5
-2.0
2.0
2.5
-1.5
2.0
2.5
-1.0
2.0
2.5
-0.5
2.0
2.5
-3.1E-182.0
2.5
0.5
2.0
2.5
1.0
2.0
2.5
1.5
2.0
2.0
2.5
2.0
2.5
2.0
2.0
2.4977642.4977642.0
-2.49776-2.497761.0
-2.5
-2.0
1.0
-2.5
-1.5
1.0
-2.5
-1.0
1.0
-2.5
-0.5
1.0
-2.5
-3.5E-181.0
-2.5
0.5
1.0
-2.5
1.0
1.0
-2.5
1.5
1.0
-2.497762.4977641.0
-2.5
2.0
1.0
-2.0
-2.5
1.0
-2.0
2.5
1.0
-1.5
-2.5
1.0
-1.5
2.5
1.0
-1.0
-2.5
1.0
-1.0
2.5
1.0
-0.5
-2.5
1.0
-0.5
2.5
1.0
-2.5E-18-2.5
1.0
-2.5E-182.5
1.0
0.5
-2.5
1.0
0.5
2.5
1.0
1.0
-2.5
1.0
1.0
2.5
1.0
1.5
-2.5
1.0
1.5
2.5
1.0
2.0
-2.5
1.0
2.497764-2.497761.0
2.5
-2.0
1.0
2.5
-1.5
1.0
2.5
-1.0
1.0
2.5
-0.5
1.0
2.5
-2.9E-181.0
2.5
0.5
1.0
2.5
1.0
1.0
2.5
1.5
1.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
1731
2.0
2.5
1.0
GRID
1732
2.5
2.0
1.0
GRID
1733
2.4977642.4977641.0
GRID
1734
-0.25
3.33E-165.0
$$
$$ SPOINT Data
$$
$$
$$------------------------------------------------------------------------------$
$$
Group Definitions
$
$$------------------------------------------------------------------------------$
$$
$$ RBE2 Elements - Multiple dependent nodes
$$
RBE2
1553
1734 123456
1478
1479
1480
1481
1482+
+
1489
1493
1500
1504
1511
1515
1522
1526+
+
1533
1534
1535
1536
1537
$
$HMMOVE
6
$
1553
$
$ CQUAD4 Elements
$
CQUAD4
1101
4
1332
1341
1342
1333
CQUAD4
1102
4
1333
1342
1343
1334
CQUAD4
1103
4
1334
1343
1344
1335
CQUAD4
1104
4
1335
1344
1345
1336
CQUAD4
1105
4
1336
1345
1346
1337
CQUAD4
1106
4
1337
1346
1347
1338
CQUAD4
1107
4
1338
1347
1348
1339
CQUAD4
1108
4
1339
1348
1349
1340
CQUAD4
1109
4
1341
1350
1351
1342
CQUAD4
1110
4
1342
1351
1352
1343
CQUAD4
1111
4
1343
1352
1353
1344
CQUAD4
1112
4
1344
1353
1354
1345
CQUAD4
1113
4
1345
1354
1355
1346
CQUAD4
1114
4
1346
1355
1356
1347
CQUAD4
1115
4
1347
1356
1357
1348
CQUAD4
1116
4
1348
1357
1358
1349
CQUAD4
1117
4
1350
1359
1360
1351
CQUAD4
1118
4
1351
1360
1361
1352
CQUAD4
1119
4
1352
1361
1362
1353
CQUAD4
1120
4
1353
1362
1363
1354
CQUAD4
1121
4
1354
1363
1364
1355
CQUAD4
1122
4
1355
1364
1365
1356
CQUAD4
1123
4
1356
1365
1366
1357
CQUAD4
1124
4
1357
1366
1367
1358
CQUAD4
1125
4
1359
1368
1369
1360
CQUAD4
1126
4
1360
1369
1370
1361
CQUAD4
1127
4
1361
1370
1371
1362
CQUAD4
1128
4
1362
1371
1372
1363
CQUAD4
1129
4
1363
1372
1373
1364
CQUAD4
1130
4
1364
1373
1374
1365
CQUAD4
1131
4
1365
1374
1375
1366
CQUAD4
1132
4
1366
1375
1376
1367
CQUAD4
1133
4
1368
1377
1378
1369
CQUAD4
1134
4
1369
1378
1379
1370
CQUAD4
1135
4
1370
1379
1380
1371
CQUAD4
1136
4
1371
1380
1381
1372
CQUAD4
1137
4
1372
1381
1382
1373
CQUAD4
1138
4
1373
1382
1383
1374
CQUAD4
1139
4
1374
1383
1384
1375
CQUAD4
1140
4
1375
1384
1385
1376
CQUAD4
1141
4
1377
1386
1387
1378
CQUAD4
1142
4
1378
1387
1388
1379
CQUAD4
1143
4
1379
1388
1389
1380
CQUAD4
1144
4
1380
1389
1390
1381
CQUAD4
1145
4
1381
1390
1391
1382
CQUAD4
1146
4
1382
1391
1392
1383

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

499

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

500

1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1383
1384
1386
1387
1388
1389
1390
1391
1392
1393
1395
1396
1397
1398
1399
1400
1401
1402
1413
1414
1415
1416
1417
1418
1419
1420
1404
1405
1406
1407
1408
1409
1410
1411
1431
1433
1421
1340
1435
1349
1437
1358
1439
1367
1441
1376
1443
1385
1445
1394
1447
1403
1449
1412
1431
1413
1414
1433
1415
1416
1417
1418
1419
1420
1421
1432
1434
1436
1435

1392
1393
1395
1396
1397
1398
1399
1400
1401
1402
1404
1405
1406
1407
1408
1409
1410
1411
1332
1333
1334
1335
1336
1337
1338
1339
1422
1423
1424
1425
1426
1427
1428
1429
1433
1435
1340
1349
1437
1358
1439
1367
1441
1376
1443
1385
1445
1394
1447
1403
1449
1412
1451
1430
1733
1732
1730
1731
1729
1728
1727
1726
1725
1724
1723
1722
1721
1719
1720

1393
1394
1396
1397
1398
1399
1400
1401
1402
1403
1405
1406
1407
1408
1409
1410
1411
1412
1333
1334
1335
1336
1337
1338
1339
1340
1423
1424
1425
1426
1427
1428
1429
1430
1332
1341
1434
1436
1350
1438
1359
1440
1368
1442
1377
1444
1386
1446
1395
1448
1404
1450
1422
1452
1731
1733
1732
1720
1730
1729
1728
1727
1726
1725
1724
1723
1722
1721
1718

1384
1385
1387
1388
1389
1390
1391
1392
1393
1394
1396
1397
1398
1399
1400
1401
1402
1403
1414
1415
1416
1417
1418
1419
1420
1421
1405
1406
1407
1408
1409
1410
1411
1412
1413
1332
1432
1434
1341
1436
1350
1438
1359
1440
1368
1442
1377
1444
1386
1446
1395
1448
1404
1450
1433
1431
1413
1435
1414
1415
1416
1417
1418
1419
1420
1421
1432
1434
1437

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284

Altair Engineering

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1438
1437
1440
1439
1442
1441
1444
1443
1446
1445
1448
1447
1450
1449
1452
1451
1422
1423
1424
1425
1426
1427
1428
1429
1430
1732
1733
1730
1731
1729
1728
1727
1726
1725
1724
1723
1722
1721
1719
1720
1717
1718
1715
1716
1713
1714
1711
1712
1709
1710
1707
1708
1705
1706
1694
1703
1704
1702
1701
1700
1699
1698
1697
1696
1695
1692
1693
1690
1691

1717
1718
1715
1716
1713
1714
1711
1712
1709
1710
1707
1708
1705
1706
1694
1703
1704
1702
1701
1700
1699
1698
1697
1696
1695
1692
1693
1690
1691
1689
1688
1687
1686
1685
1684
1683
1682
1681
1679
1680
1677
1678
1675
1676
1673
1674
1671
1672
1669
1670
1667
1668
1665
1666
1654
1663
1664
1662
1661
1660
1659
1658
1657
1656
1655
1652
1653
1650
1651

1719
1716
1717
1714
1715
1712
1713
1710
1711
1708
1709
1706
1707
1703
1705
1704
1702
1701
1700
1699
1698
1697
1696
1695
1694
1693
1691
1692
1680
1690
1689
1688
1687
1686
1685
1684
1683
1682
1681
1678
1679
1676
1677
1674
1675
1672
1673
1670
1671
1668
1669
1666
1667
1663
1665
1664
1662
1661
1660
1659
1658
1657
1656
1655
1654
1653
1651
1652
1640

1436
1439
1438
1441
1440
1443
1442
1445
1444
1447
1446
1449
1448
1451
1450
1422
1423
1424
1425
1426
1427
1428
1429
1430
1452
1733
1731
1732
1720
1730
1729
1728
1727
1726
1725
1724
1723
1722
1721
1718
1719
1716
1717
1714
1715
1712
1713
1710
1711
1708
1709
1706
1707
1703
1705
1704
1702
1701
1700
1699
1698
1697
1696
1695
1694
1693
1691
1692
1680

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

501

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

502

1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1689
1688
1687
1686
1685
1684
1683
1682
1681
1679
1680
1677
1678
1675
1676
1673
1674
1671
1672
1669
1670
1667
1668
1665
1666
1654
1663
1664
1662
1661
1660
1659
1658
1657
1656
1655
1652
1653
1650
1651
1649
1648
1647
1646
1645
1644
1643
1642
1641
1639
1640
1637
1638
1635
1636
1633
1634
1631
1632
1629
1630
1627
1628
1625
1626
1614
1623
1624
1622

1649
1648
1647
1646
1645
1644
1643
1642
1641
1639
1640
1637
1638
1635
1636
1633
1634
1631
1632
1629
1630
1627
1628
1625
1626
1614
1623
1624
1622
1621
1620
1619
1618
1617
1616
1615
1612
1613
1610
1611
1609
1608
1607
1606
1605
1604
1603
1602
1601
1599
1600
1597
1598
1595
1596
1593
1594
1591
1592
1589
1590
1587
1588
1585
1586
1574
1583
1584
1582

1650
1649
1648
1647
1646
1645
1644
1643
1642
1641
1638
1639
1636
1637
1634
1635
1632
1633
1630
1631
1628
1629
1626
1627
1623
1625
1624
1622
1621
1620
1619
1618
1617
1616
1615
1614
1613
1611
1612
1600
1610
1609
1608
1607
1606
1605
1604
1603
1602
1601
1598
1599
1596
1597
1594
1595
1592
1593
1590
1591
1588
1589
1586
1587
1583
1585
1584
1582
1581

1690
1689
1688
1687
1686
1685
1684
1683
1682
1681
1678
1679
1676
1677
1674
1675
1672
1673
1670
1671
1668
1669
1666
1667
1663
1665
1664
1662
1661
1660
1659
1658
1657
1656
1655
1654
1653
1651
1652
1640
1650
1649
1648
1647
1646
1645
1644
1643
1642
1641
1638
1639
1636
1637
1634
1635
1632
1633
1630
1631
1628
1629
1626
1627
1623
1625
1624
1622
1621

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1417
1418
1419
1420
1421
1422
1423
1424
1429
1430

Altair Engineering

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1621
1620
1619
1618
1617
1616
1615
1612
1613
1610
1572
1611
1569
1609
1567
1608
1565
1607
1563
1606
1561
1605
1559
1604
1557
1603
1555
1602
1601
1553
1599
1571
1568
1600
1566
1564
1562
1560
1558
1556
1554
1552
1597
1551
1549
1598
1548
1547
1546
1545
1544
1543
1542
1541
1595
1540
1538
1596
1537
1532
1531
1530
1593
1529
1527
1594
1526
1521
1520

1581
1580
1579
1578
1577
1576
1575
1572
1573
1569
1571
1570
1568
1567
1566
1565
1564
1563
1562
1561
1560
1559
1558
1557
1556
1555
1554
1553
1552
1552
1541
1551
1549
1550
1548
1547
1546
1545
1544
1543
1542
1541
1530
1540
1538
1539
1537
1536
1535
1534
1533
1532
1531
1530
1519
1529
1527
1528
1526
1521
1520
1519
1508
1518
1516
1517
1515
1510
1509

1580
1579
1578
1577
1576
1575
1574
1573
1570
1572
1570
1550
1571
1569
1568
1567
1566
1565
1564
1563
1562
1561
1560
1559
1558
1557
1556
1555
1553
1554
1552
1550
1551
1539
1549
1548
1547
1546
1545
1544
1543
1542
1541
1539
1540
1528
1538
1537
1536
1535
1534
1533
1532
1531
1530
1528
1529
1517
1527
1522
1521
1520
1519
1517
1518
1506
1516
1511
1510

1620
1619
1618
1617
1616
1615
1614
1613
1611
1612
1573
1600
1572
1610
1569
1609
1567
1608
1565
1607
1563
1606
1561
1605
1559
1604
1557
1603
1602
1555
1601
1570
1571
1598
1568
1566
1564
1562
1560
1558
1556
1554
1599
1550
1551
1596
1549
1548
1547
1546
1545
1544
1543
1542
1597
1539
1540
1594
1538
1533
1532
1531
1595
1528
1529
1592
1527
1522
1521

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

503

CQUAD4
1431
4
1519
CQUAD4
1432
4
1591
CQUAD4
1433
4
1518
CQUAD4
1434
4
1516
CQUAD4
1435
4
1592
CQUAD4
1436
4
1515
CQUAD4
1441
4
1510
CQUAD4
1442
4
1509
CQUAD4
1443
4
1508
CQUAD4
1444
4
1589
CQUAD4
1445
4
1507
CQUAD4
1446
4
1505
CQUAD4
1447
4
1590
CQUAD4
1448
4
1504
CQUAD4
1453
4
1499
CQUAD4
1454
4
1498
CQUAD4
1455
4
1497
CQUAD4
1456
4
1587
CQUAD4
1457
4
1496
CQUAD4
1458
4
1494
CQUAD4
1459
4
1588
CQUAD4
1460
4
1493
CQUAD4
1465
4
1488
CQUAD4
1466
4
1487
CQUAD4
1467
4
1486
CQUAD4
1468
4
1585
CQUAD4
1469
4
1485
CQUAD4
1470
4
1483
CQUAD4
1471
4
1586
CQUAD4
1472
4
1482
CQUAD4
1473
4
1481
CQUAD4
1474
4
1480
CQUAD4
1475
4
1479
CQUAD4
1476
4
1478
CQUAD4
1477
4
1477
CQUAD4
1478
4
1476
CQUAD4
1479
4
1475
CQUAD4
1480
4
1574
CQUAD4
1481
4
1583
CQUAD4
1482
4
1474
CQUAD4
1483
4
1584
CQUAD4
1484
4
1472
CQUAD4
1485
4
1582
CQUAD4
1486
4
1471
CQUAD4
1487
4
1581
CQUAD4
1488
4
1470
CQUAD4
1489
4
1580
CQUAD4
1490
4
1469
CQUAD4
1491
4
1579
CQUAD4
1492
4
1468
CQUAD4
1493
4
1578
CQUAD4
1494
4
1467
CQUAD4
1495
4
1577
CQUAD4
1496
4
1466
CQUAD4
1497
4
1576
CQUAD4
1498
4
1465
CQUAD4
1499
4
1575
CQUAD4
1500
4
1464
$
$ CHEXA Elements: First Order
$
CHEXA
601
1
100
+
729
728
CHEXA
602
1
82
+
732
731
CHEXA
603
1
83
+
734
733
CHEXA
604
1
84
+
736
735

504

1508
1497
1507
1505
1506
1504
1499
1498
1497
1486
1496
1494
1495
1493
1488
1487
1486
1475
1485
1483
1484
1482
1477
1476
1475
1464
1474
1472
1473
1471
1470
1469
1468
1467
1466
1465
1464
1453
1462
1463
1463
1461
1461
1460
1460
1459
1459
1458
1458
1457
1457
1456
1456
1455
1455
1454
1454
1453

1509
1508
1506
1507
1495
1505
1500
1499
1498
1497
1495
1496
1484
1494
1489
1488
1487
1486
1484
1485
1473
1483
1478
1477
1476
1475
1473
1474
1462
1472
1471
1470
1469
1468
1467
1466
1465
1464
1463
1462
1461
1463
1460
1461
1459
1460
1458
1459
1457
1458
1456
1457
1455
1456
1454
1455
1453
1454

1520
1593
1517
1518
1590
1516
1511
1510
1509
1591
1506
1507
1588
1505
1500
1499
1498
1589
1495
1496
1586
1494
1489
1488
1487
1587
1484
1485
1583
1483
1482
1481
1480
1479
1478
1477
1476
1585
1584
1473
1582
1474
1581
1472
1580
1471
1579
1470
1578
1469
1577
1468
1576
1467
1575
1466
1574
1465

102

82

727

730+

83

728

729+

84

731

732+

85

733

734+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

605
738
606
740
607
742
608
744
609
746
610
748
611
749
612
751
613
752
614
753
615
754
616
755
617
756
618
757
619
758
620
759
621
760
622
762
623
763
624
764
625
765
626
766
627
767
628
768
629
769
630
770
631
771
632
773
633
774
634
775
635
776
636
777
637
778
638
779
639

Altair Engineering

1
737
1
739
1
741
1
743
1
745
1
747
1
729
1
732
1
734
1
736
1
738
1
740
1
742
1
744
1
746
1
748
1
749
1
751
1
752
1
753
1
754
1
755
1
756
1
757
1
758
1
759
1
760
1
762
1
763
1
764
1
765
1
766
1
767
1
768
1

85

86

735

736+

86

87

737

738+

87

88

739

740+

88

89

741

742+

89

90

743

744+

90

103

101

745

746+

102

104

10

730

750+

10

11

729

749+

11

12

732

751+

12

13

734

752+

13

14

736

753+

14

15

738

754+

15

16

740

755+

16

17

742

756+

17

18

744

757+

18

105

103

746

758+

104

106

19

10

750

761+

10

19

20

11

749

760+

11

20

21

12

751

762+

12

21

22

13

752

763+

13

22

23

14

753

764+

14

23

24

15

754

765+

15

24

25

16

755

766+

16

25

26

17

756

767+

17

26

27

18

757

768+

18

27

107

105

758

769+

106

108

28

19

761

772+

19

28

29

20

760

771+

20

29

30

21

762

773+

21

30

31

22

763

774+

22

31

32

23

764

775+

23

32

33

24

765

776+

24

33

34

25

766

777+

25

34

35

26

767

778+

26

35

36

27

768

779+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

505

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

506

780
640
781
641
782
642
784
643
785
644
786
645
787
646
788
647
789
648
790
649
791
650
792
651
793
652
795
653
796
654
797
655
798
656
799
657
800
658
801
659
802
660
803
661
804
662
806
663
807
664
808
665
809
666
810
667
811
668
812
669
813
670
814
671
815
672
817
673
818

769
1
770
1
771
1
773
1
774
1
775
1
776
1
777
1
778
1
779
1
780
1
781
1
782
1
784
1
785
1
786
1
787
1
788
1
789
1
790
1
791
1
792
1
793
1
795
1
796
1
797
1
798
1
799
1
800
1
801
1
802
1
803
1
804
1
806
1
807

27

36

109

107

769

780+

108

110

37

28

772

783+

28

37

38

29

771

782+

29

38

39

30

773

784+

30

39

40

31

774

785+

31

40

41

32

775

786+

32

41

42

33

776

787+

33

42

43

34

777

788+

34

43

44

35

778

789+

35

44

45

36

779

790+

36

45

111

109

780

791+

110

112

46

37

783

794+

37

46

47

38

782

793+

38

47

48

39

784

795+

39

48

49

40

785

796+

40

49

50

41

786

797+

41

50

51

42

787

798+

42

51

52

43

788

799+

43

52

53

44

789

800+

44

53

54

45

790

801+

45

54

113

111

791

802+

112

114

55

46

794

805+

46

55

56

47

793

804+

47

56

57

48

795

806+

48

57

58

49

796

807+

49

58

59

50

797

808+

50

59

60

51

798

809+

51

60

61

52

799

810+

52

61

62

53

800

811+

53

62

63

54

801

812+

54

63

115

113

802

813+

114

116

64

55

805

816+

55

64

65

56

804

815+

56

65

66

57

806

817+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

674
819
675
820
676
821
677
822
678
823
679
824
680
825
681
826
682
828
683
829
684
830
685
831
686
832
687
833
688
834
689
835
690
836
691
837
692
839
693
840
694
841
695
842
696
843
697
844
698
845
699
846
700
847
701
850
702
853
703
855
704
857
705
859
706
861
707
863
708

Altair Engineering

1
808
1
809
1
810
1
811
1
812
1
813
1
814
1
815
1
817
1
818
1
819
1
820
1
821
1
822
1
823
1
824
1
825
1
826
1
828
1
829
1
830
1
831
1
832
1
833
1
834
1
835
1
836
1
849
1
852
1
854
1
856
1
858
1
860
1
862
1

57

66

67

58

807

818+

58

67

68

59

808

819+

59

68

69

60

809

820+

60

69

70

61

810

821+

61

70

71

62

811

822+

62

71

72

63

812

823+

63

72

117

115

813

824+

116

118

73

64

816

827+

64

73

74

65

815

826+

65

74

75

66

817

828+

66

75

76

67

818

829+

67

76

77

68

819

830+

68

77

78

69

820

831+

69

78

79

70

821

832+

70

79

80

71

822

833+

71

80

81

72

823

834+

72

81

119

117

824

835+

118

120

91

73

827

838+

73

91

92

74

826

837+

74

92

93

75

828

839+

75

93

94

76

829

840+

76

94

95

77

830

841+

77

95

96

78

831

842+

78

96

97

79

832

843+

79

97

98

80

833

844+

80

98

99

81

834

845+

81

99

121

119

835

846+

727

730

729

728

848

851+

728

729

732

731

849

850+

731

732

734

733

852

853+

733

734

736

735

854

855+

735

736

738

737

856

857+

737

738

740

739

858

859+

739

740

742

741

860

861+

741

742

744

743

862

863+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

507

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

508

865
709
867
710
869
711
870
712
872
713
873
714
874
715
875
716
876
717
877
718
878
719
879
720
880
721
881
722
883
723
884
724
885
725
886
726
887
727
888
728
889
729
890
730
891
731
892
732
894
733
895
734
896
735
897
736
898
737
899
738
900
739
901
740
902
741
903
742
905

864
1
866
1
868
1
850
1
853
1
855
1
857
1
859
1
861
1
863
1
865
1
867
1
869
1
870
1
872
1
873
1
874
1
875
1
876
1
877
1
878
1
879
1
880
1
881
1
883
1
884
1
885
1
886
1
887
1
888
1
889
1
890
1
891
1
892
1
894

743

744

746

745

864

865+

745

746

748

747

866

867+

730

750

749

729

851

871+

729

749

751

732

850

870+

732

751

752

734

853

872+

734

752

753

736

855

873+

736

753

754

738

857

874+

738

754

755

740

859

875+

740

755

756

742

861

876+

742

756

757

744

863

877+

744

757

758

746

865

878+

746

758

759

748

867

879+

750

761

760

749

871

882+

749

760

762

751

870

881+

751

762

763

752

872

883+

752

763

764

753

873

884+

753

764

765

754

874

885+

754

765

766

755

875

886+

755

766

767

756

876

887+

756

767

768

757

877

888+

757

768

769

758

878

889+

758

769

770

759

879

890+

761

772

771

760

882

893+

760

771

773

762

881

892+

762

773

774

763

883

894+

763

774

775

764

884

895+

764

775

776

765

885

896+

765

776

777

766

886

897+

766

777

778

767

887

898+

767

778

779

768

888

899+

768

779

780

769

889

900+

769

780

781

770

890

901+

772

783

782

771

893

904+

771

782

784

773

892

903+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

743
906
744
907
745
908
746
909
747
910
748
911
749
912
750
913
751
914
752
916
753
917
754
918
755
919
756
920
757
921
758
922
759
923
760
924
761
925
762
927
763
928
764
929
765
930
766
931
767
932
768
933
769
934
770
935
771
936
772
938
773
939
774
940
775
941
776
942
777

Altair Engineering

1
895
1
896
1
897
1
898
1
899
1
900
1
901
1
902
1
903
1
905
1
906
1
907
1
908
1
909
1
910
1
911
1
912
1
913
1
914
1
916
1
917
1
918
1
919
1
920
1
921
1
922
1
923
1
924
1
925
1
927
1
928
1
929
1
930
1
931
1

773

784

785

774

894

905+

774

785

786

775

895

906+

775

786

787

776

896

907+

776

787

788

777

897

908+

777

788

789

778

898

909+

778

789

790

779

899

910+

779

790

791

780

900

911+

780

791

792

781

901

912+

783

794

793

782

904

915+

782

793

795

784

903

914+

784

795

796

785

905

916+

785

796

797

786

906

917+

786

797

798

787

907

918+

787

798

799

788

908

919+

788

799

800

789

909

920+

789

800

801

790

910

921+

790

801

802

791

911

922+

791

802

803

792

912

923+

794

805

804

793

915

926+

793

804

806

795

914

925+

795

806

807

796

916

927+

796

807

808

797

917

928+

797

808

809

798

918

929+

798

809

810

799

919

930+

799

810

811

800

920

931+

800

811

812

801

921

932+

801

812

813

802

922

933+

802

813

814

803

923

934+

805

816

815

804

926

937+

804

815

817

806

925

936+

806

817

818

807

927

938+

807

818

819

808

928

939+

808

819

820

809

929

940+

809

820

821

810

930

941+

810

821

822

811

931

942+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

509

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

510

943
778
944
779
945
780
946
781
947
782
949
783
950
784
951
785
952
786
953
787
954
788
955
789
956
790
957
791
958
792
960
793
961
794
962
795
963
796
964
797
965
798
966
799
967
800
968
801
971
802
974
803
976
804
978
805
980
806
982
807
984
808
986
809
988
810
990
811
991

932
1
933
1
934
1
935
1
936
1
938
1
939
1
940
1
941
1
942
1
943
1
944
1
945
1
946
1
947
1
949
1
950
1
951
1
952
1
953
1
954
1
955
1
956
1
957
1
970
1
973
1
975
1
977
1
979
1
981
1
983
1
985
1
987
1
989
1
971

811

822

823

812

932

943+

812

823

824

813

933

944+

813

824

825

814

934

945+

816

827

826

815

937

948+

815

826

828

817

936

947+

817

828

829

818

938

949+

818

829

830

819

939

950+

819

830

831

820

940

951+

820

831

832

821

941

952+

821

832

833

822

942

953+

822

833

834

823

943

954+

823

834

835

824

944

955+

824

835

836

825

945

956+

827

838

837

826

948

959+

826

837

839

828

947

958+

828

839

840

829

949

960+

829

840

841

830

950

961+

830

841

842

831

951

962+

831

842

843

832

952

963+

832

843

844

833

953

964+

833

844

845

834

954

965+

834

845

846

835

955

966+

835

846

847

836

956

967+

848

851

850

849

969

972+

849

850

853

852

970

971+

852

853

855

854

973

974+

854

855

857

856

975

976+

856

857

859

858

977

978+

858

859

861

860

979

980+

860

861

863

862

981

982+

862

863

865

864

983

984+

864

865

867

866

985

986+

866

867

869

868

987

988+

851

871

870

850

972

992+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

812
993
813
994
814
995
815
996
816
997
817
998
818
999
819
1000
820
1001
821
1002
822
1004
823
1005
824
1006
825
1007
826
1008
827
1009
828
1010
829
1011
830
1012
831
1013
832
1015
833
1016
834
1017
835
1018
836
1019
837
1020
838
1021
839
1022
840
1023
841
1024
842
1026
843
1027
844
1028
845
1029
846

Altair Engineering

1
974
1
976
1
978
1
980
1
982
1
984
1
986
1
988
1
990
1
991
1
993
1
994
1
995
1
996
1
997
1
998
1
999
1
1000
1
1001
1
1002
1
1004
1
1005
1
1006
1
1007
1
1008
1
1009
1
1010
1
1011
1
1012
1
1013
1
1015
1
1016
1
1017
1
1018
1

850

870

872

853

971

991+

853

872

873

855

974

993+

855

873

874

857

976

994+

857

874

875

859

978

995+

859

875

876

861

980

996+

861

876

877

863

982

997+

863

877

878

865

984

998+

865

878

879

867

986

999+

867

879

880

869

988

1000+

871

882

881

870

992

1003+

870

881

883

872

991

1002+

872

883

884

873

993

1004+

873

884

885

874

994

1005+

874

885

886

875

995

1006+

875

886

887

876

996

1007+

876

887

888

877

997

1008+

877

888

889

878

998

1009+

878

889

890

879

999

1010+

879

890

891

880

1000

1011+

882

893

892

881

1003

1014+

881

892

894

883

1002

1013+

883

894

895

884

1004

1015+

884

895

896

885

1005

1016+

885

896

897

886

1006

1017+

886

897

898

887

1007

1018+

887

898

899

888

1008

1019+

888

899

900

889

1009

1020+

889

900

901

890

1010

1021+

890

901

902

891

1011

1022+

893

904

903

892

1014

1025+

892

903

905

894

1013

1024+

894

905

906

895

1015

1026+

895

906

907

896

1016

1027+

896

907

908

897

1017

1028+

897

908

909

898

1018

1029+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

511

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

512

1030
847
1031
848
1032
849
1033
850
1034
851
1035
852
1037
853
1038
854
1039
855
1040
856
1041
857
1042
858
1043
859
1044
860
1045
861
1046
862
1048
863
1049
864
1050
865
1051
866
1052
867
1053
868
1054
869
1055
870
1056
871
1057
872
1059
873
1060
874
1061
875
1062
876
1063
877
1064
878
1065
879
1066
880
1067

1019
1
1020
1
1021
1
1022
1
1023
1
1024
1
1026
1
1027
1
1028
1
1029
1
1030
1
1031
1
1032
1
1033
1
1034
1
1035
1
1037
1
1038
1
1039
1
1040
1
1041
1
1042
1
1043
1
1044
1
1045
1
1046
1
1048
1
1049
1
1050
1
1051
1
1052
1
1053
1
1054
1
1055
1
1056

898

909

910

899

1019

1030+

899

910

911

900

1020

1031+

900

911

912

901

1021

1032+

901

912

913

902

1022

1033+

904

915

914

903

1025

1036+

903

914

916

905

1024

1035+

905

916

917

906

1026

1037+

906

917

918

907

1027

1038+

907

918

919

908

1028

1039+

908

919

920

909

1029

1040+

909

920

921

910

1030

1041+

910

921

922

911

1031

1042+

911

922

923

912

1032

1043+

912

923

924

913

1033

1044+

915

926

925

914

1036

1047+

914

925

927

916

1035

1046+

916

927

928

917

1037

1048+

917

928

929

918

1038

1049+

918

929

930

919

1039

1050+

919

930

931

920

1040

1051+

920

931

932

921

1041

1052+

921

932

933

922

1042

1053+

922

933

934

923

1043

1054+

923

934

935

924

1044

1055+

926

937

936

925

1047

1058+

925

936

938

927

1046

1057+

927

938

939

928

1048

1059+

928

939

940

929

1049

1060+

929

940

941

930

1050

1061+

930

941

942

931

1051

1062+

931

942

943

932

1052

1063+

932

943

944

933

1053

1064+

933

944

945

934

1054

1065+

934

945

946

935

1055

1066+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

881
1068
882
1070
883
1071
884
1072
885
1073
886
1074
887
1075
888
1076
889
1077
890
1078
891
1079
892
1081
893
1082
894
1083
895
1084
896
1085
897
1086
898
1087
899
1088
900
1089
901
1092
902
1095
903
1097
904
1099
905
1101
906
1103
907
1105
908
1107
909
1109
910
1111
911
1112
912
1114
913
1115
914
1116
915

Altair Engineering

1
1057
1
1059
1
1060
1
1061
1
1062
1
1063
1
1064
1
1065
1
1066
1
1067
1
1068
1
1070
1
1071
1
1072
1
1073
1
1074
1
1075
1
1076
1
1077
1
1078
1
1091
1
1094
1
1096
1
1098
1
1100
1
1102
1
1104
1
1106
1
1108
1
1110
1
1092
1
1095
1
1097
1
1099
1

937

948

947

936

1058

1069+

936

947

949

938

1057

1068+

938

949

950

939

1059

1070+

939

950

951

940

1060

1071+

940

951

952

941

1061

1072+

941

952

953

942

1062

1073+

942

953

954

943

1063

1074+

943

954

955

944

1064

1075+

944

955

956

945

1065

1076+

945

956

957

946

1066

1077+

948

959

958

947

1069

1080+

947

958

960

949

1068

1079+

949

960

961

950

1070

1081+

950

961

962

951

1071

1082+

951

962

963

952

1072

1083+

952

963

964

953

1073

1084+

953

964

965

954

1074

1085+

954

965

966

955

1075

1086+

955

966

967

956

1076

1087+

956

967

968

957

1077

1088+

969

972

971

970

1090

1093+

970

971

974

973

1091

1092+

973

974

976

975

1094

1095+

975

976

978

977

1096

1097+

977

978

980

979

1098

1099+

979

980

982

981

1100

1101+

981

982

984

983

1102

1103+

983

984

986

985

1104

1105+

985

986

988

987

1106

1107+

987

988

990

989

1108

1109+

972

992

991

971

1093

1113+

971

991

993

974

1092

1112+

974

993

994

976

1095

1114+

976

994

995

978

1097

1115+

978

995

996

980

1099

1116+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

513

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

514

1117
916
1118
917
1119
918
1120
919
1121
920
1122
921
1123
922
1125
923
1126
924
1127
925
1128
926
1129
927
1130
928
1131
929
1132
930
1133
931
1134
932
1136
933
1137
934
1138
935
1139
936
1140
937
1141
938
1142
939
1143
940
1144
941
1145
942
1147
943
1148
944
1149
945
1150
946
1151
947
1152
948
1153
949
1154

1101
1
1103
1
1105
1
1107
1
1109
1
1111
1
1112
1
1114
1
1115
1
1116
1
1117
1
1118
1
1119
1
1120
1
1121
1
1122
1
1123
1
1125
1
1126
1
1127
1
1128
1
1129
1
1130
1
1131
1
1132
1
1133
1
1134
1
1136
1
1137
1
1138
1
1139
1
1140
1
1141
1
1142
1
1143

980

996

997

982

1101

1117+

982

997

998

984

1103

1118+

984

998

999

986

1105

1119+

986

999

1000

988

1107

1120+

988

1000

1001

990

1109

1121+

992

1003

1002

991

1113

1124+

991

1002

1004

993

1112

1123+

993

1004

1005

994

1114

1125+

994

1005

1006

995

1115

1126+

995

1006

1007

996

1116

1127+

996

1007

1008

997

1117

1128+

997

1008

1009

998

1118

1129+

998

1009

1010

999

1119

1130+

999

1010

1011

1000

1120

1131+

1000

1011

1012

1001

1121

1132+

1003

1014

1013

1002

1124

1135+

1002

1013

1015

1004

1123

1134+

1004

1015

1016

1005

1125

1136+

1005

1016

1017

1006

1126

1137+

1006

1017

1018

1007

1127

1138+

1007

1018

1019

1008

1128

1139+

1008

1019

1020

1009

1129

1140+

1009

1020

1021

1010

1130

1141+

1010

1021

1022

1011

1131

1142+

1011

1022

1023

1012

1132

1143+

1014

1025

1024

1013

1135

1146+

1013

1024

1026

1015

1134

1145+

1015

1026

1027

1016

1136

1147+

1016

1027

1028

1017

1137

1148+

1017

1028

1029

1018

1138

1149+

1018

1029

1030

1019

1139

1150+

1019

1030

1031

1020

1140

1151+

1020

1031

1032

1021

1141

1152+

1021

1032

1033

1022

1142

1153+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

950
1155
951
1156
952
1158
953
1159
954
1160
955
1161
956
1162
957
1163
958
1164
959
1165
960
1166
961
1167
962
1169
963
1170
964
1171
965
1172
966
1173
967
1174
968
1175
969
1176
970
1177
971
1178
972
1180
973
1181
974
1182
975
1183
976
1184
977
1185
978
1186
979
1187
980
1188
981
1189
982
1191
983
1192
984

Altair Engineering

1
1144
1
1145
1
1147
1
1148
1
1149
1
1150
1
1151
1
1152
1
1153
1
1154
1
1155
1
1156
1
1158
1
1159
1
1160
1
1161
1
1162
1
1163
1
1164
1
1165
1
1166
1
1167
1
1169
1
1170
1
1171
1
1172
1
1173
1
1174
1
1175
1
1176
1
1177
1
1178
1
1180
1
1181
1

1022

1033

1034

1023

1143

1154+

1025

1036

1035

1024

1146

1157+

1024

1035

1037

1026

1145

1156+

1026

1037

1038

1027

1147

1158+

1027

1038

1039

1028

1148

1159+

1028

1039

1040

1029

1149

1160+

1029

1040

1041

1030

1150

1161+

1030

1041

1042

1031

1151

1162+

1031

1042

1043

1032

1152

1163+

1032

1043

1044

1033

1153

1164+

1033

1044

1045

1034

1154

1165+

1036

1047

1046

1035

1157

1168+

1035

1046

1048

1037

1156

1167+

1037

1048

1049

1038

1158

1169+

1038

1049

1050

1039

1159

1170+

1039

1050

1051

1040

1160

1171+

1040

1051

1052

1041

1161

1172+

1041

1052

1053

1042

1162

1173+

1042

1053

1054

1043

1163

1174+

1043

1054

1055

1044

1164

1175+

1044

1055

1056

1045

1165

1176+

1047

1058

1057

1046

1168

1179+

1046

1057

1059

1048

1167

1178+

1048

1059

1060

1049

1169

1180+

1049

1060

1061

1050

1170

1181+

1050

1061

1062

1051

1171

1182+

1051

1062

1063

1052

1172

1183+

1052

1063

1064

1053

1173

1184+

1053

1064

1065

1054

1174

1185+

1054

1065

1066

1055

1175

1186+

1055

1066

1067

1056

1176

1187+

1058

1069

1068

1057

1179

1190+

1057

1068

1070

1059

1178

1189+

1059

1070

1071

1060

1180

1191+

1060

1071

1072

1061

1181

1192+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

515

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

516

1193
985
1194
986
1195
987
1196
988
1197
989
1198
990
1199
991
1200
992
1202
993
1203
994
1204
995
1205
996
1206
997
1207
998
1208
999
1209
1000
1210
1001
1213
1002
1216
1003
1218
1004
1220
1005
1222
1006
1224
1007
1226
1008
1228
1009
1230
1010
1232
1011
1233
1012
1235
1013
1236
1014
1237
1015
1238
1016
1239
1017
1240
1018
1241

1182
1
1183
1
1184
1
1185
1
1186
1
1187
1
1188
1
1189
1
1191
1
1192
1
1193
1
1194
1
1195
1
1196
1
1197
1
1198
1
1199
1
1212
1
1215
1
1217
1
1219
1
1221
1
1223
1
1225
1
1227
1
1229
1
1231
1
1213
1
1216
1
1218
1
1220
1
1222
1
1224
1
1226
1
1228

1061

1072

1073

1062

1182

1193+

1062

1073

1074

1063

1183

1194+

1063

1074

1075

1064

1184

1195+

1064

1075

1076

1065

1185

1196+

1065

1076

1077

1066

1186

1197+

1066

1077

1078

1067

1187

1198+

1069

1080

1079

1068

1190

1201+

1068

1079

1081

1070

1189

1200+

1070

1081

1082

1071

1191

1202+

1071

1082

1083

1072

1192

1203+

1072

1083

1084

1073

1193

1204+

1073

1084

1085

1074

1194

1205+

1074

1085

1086

1075

1195

1206+

1075

1086

1087

1076

1196

1207+

1076

1087

1088

1077

1197

1208+

1077

1088

1089

1078

1198

1209+

1090

1093

1092

1091

1211

1214+

1091

1092

1095

1094

1212

1213+

1094

1095

1097

1096

1215

1216+

1096

1097

1099

1098

1217

1218+

1098

1099

1101

1100

1219

1220+

1100

1101

1103

1102

1221

1222+

1102

1103

1105

1104

1223

1224+

1104

1105

1107

1106

1225

1226+

1106

1107

1109

1108

1227

1228+

1108

1109

1111

1110

1229

1230+

1093

1113

1112

1092

1214

1234+

1092

1112

1114

1095

1213

1233+

1095

1114

1115

1097

1216

1235+

1097

1115

1116

1099

1218

1236+

1099

1116

1117

1101

1220

1237+

1101

1117

1118

1103

1222

1238+

1103

1118

1119

1105

1224

1239+

1105

1119

1120

1107

1226

1240+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1019
1242
1020
1243
1021
1244
1022
1246
1023
1247
1024
1248
1025
1249
1026
1250
1027
1251
1028
1252
1029
1253
1030
1254
1031
1255
1032
1257
1033
1258
1034
1259
1035
1260
1036
1261
1037
1262
1038
1263
1039
1264
1040
1265
1041
1266
1042
1268
1043
1269
1044
1270
1045
1271
1046
1272
1047
1273
1048
1274
1049
1275
1050
1276
1051
1277
1052
1279
1053

Altair Engineering

1
1230
1
1232
1
1233
1
1235
1
1236
1
1237
1
1238
1
1239
1
1240
1
1241
1
1242
1
1243
1
1244
1
1246
1
1247
1
1248
1
1249
1
1250
1
1251
1
1252
1
1253
1
1254
1
1255
1
1257
1
1258
1
1259
1
1260
1
1261
1
1262
1
1263
1
1264
1
1265
1
1266
1
1268
1

1107

1120

1121

1109

1228

1241+

1109

1121

1122

1111

1230

1242+

1113

1124

1123

1112

1234

1245+

1112

1123

1125

1114

1233

1244+

1114

1125

1126

1115

1235

1246+

1115

1126

1127

1116

1236

1247+

1116

1127

1128

1117

1237

1248+

1117

1128

1129

1118

1238

1249+

1118

1129

1130

1119

1239

1250+

1119

1130

1131

1120

1240

1251+

1120

1131

1132

1121

1241

1252+

1121

1132

1133

1122

1242

1253+

1124

1135

1134

1123

1245

1256+

1123

1134

1136

1125

1244

1255+

1125

1136

1137

1126

1246

1257+

1126

1137

1138

1127

1247

1258+

1127

1138

1139

1128

1248

1259+

1128

1139

1140

1129

1249

1260+

1129

1140

1141

1130

1250

1261+

1130

1141

1142

1131

1251

1262+

1131

1142

1143

1132

1252

1263+

1132

1143

1144

1133

1253

1264+

1135

1146

1145

1134

1256

1267+

1134

1145

1147

1136

1255

1266+

1136

1147

1148

1137

1257

1268+

1137

1148

1149

1138

1258

1269+

1138

1149

1150

1139

1259

1270+

1139

1150

1151

1140

1260

1271+

1140

1151

1152

1141

1261

1272+

1141

1152

1153

1142

1262

1273+

1142

1153

1154

1143

1263

1274+

1143

1154

1155

1144

1264

1275+

1146

1157

1156

1145

1267

1278+

1145

1156

1158

1147

1266

1277+

1147

1158

1159

1148

1268

1279+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

517

+
CHEXA
+
CHEXA
+

1280
1054
1281
1055
1282

1269
1
1270
1
1271

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1057
1284
1058
1285
1059
1286
1060
1287
1061
1288
1062
1290
1063
1291
1064
1292
1065
1293
1066
1294
1067
1295
1068
1296
1069
1297
1070
1298
1071
1299
1072
1301
1073
1302
1074
1303
1075
1304
1076
1305
1077
1306
1078
1307
1079
1308
1080
1309
1081
1310
1082
1312
1083
1313
1084
1314
1085
1315
1086
1316
1087
1317
1088

1
1273
1
1274
1
1275
1
1276
1
1277
1
1279
1
1280
1
1281
1
1282
1
1283
1
1284
1
1285
1
1286
1
1287
1
1288
1
1290
1
1291
1
1292
1
1293
1
1294
1
1295
1
1296
1
1297
1
1298
1
1299
1
1301
1
1302
1
1303
1
1304
1
1305
1
1306
1

518

1148

1159

1160

1149

1269

1280+

1149

1160

1161

1150

1270

1281+

1151

1162

1163

1152

1272

1283+

1152

1163

1164

1153

1273

1284+

1153

1164

1165

1154

1274

1285+

1154

1165

1166

1155

1275

1286+

1157

1168

1167

1156

1278

1289+

1156

1167

1169

1158

1277

1288+

1158

1169

1170

1159

1279

1290+

1159

1170

1171

1160

1280

1291+

1160

1171

1172

1161

1281

1292+

1161

1172

1173

1162

1282

1293+

1162

1173

1174

1163

1283

1294+

1163

1174

1175

1164

1284

1295+

1164

1175

1176

1165

1285

1296+

1165

1176

1177

1166

1286

1297+

1168

1179

1178

1167

1289

1300+

1167

1178

1180

1169

1288

1299+

1169

1180

1181

1170

1290

1301+

1170

1181

1182

1171

1291

1302+

1171

1182

1183

1172

1292

1303+

1172

1183

1184

1173

1293

1304+

1173

1184

1185

1174

1294

1305+

1174

1185

1186

1175

1295

1306+

1175

1186

1187

1176

1296

1307+

1176

1187

1188

1177

1297

1308+

1179

1190

1189

1178

1300

1311+

1178

1189

1191

1180

1299

1310+

1180

1191

1192

1181

1301

1312+

1181

1192

1193

1182

1302

1313+

1182

1193

1194

1183

1303

1314+

1183

1194

1195

1184

1304

1315+

1184

1195

1196

1185

1305

1316+

1185

1196

1197

1186

1306

1317+

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
1318
1307
CHEXA
1089
1
1186
1197
1198
1187
1307
1318+
+
1319
1308
CHEXA
1090
1
1187
1198
1199
1188
1308
1319+
+
1320
1309
CHEXA
1091
1
1190
1201
1200
1189
1311
1322+
+
1321
1310
CHEXA
1092
1
1189
1200
1202
1191
1310
1321+
+
1323
1312
CHEXA
1093
1
1191
1202
1203
1192
1312
1323+
+
1324
1313
CHEXA
1094
1
1192
1203
1204
1193
1313
1324+
+
1325
1314
CHEXA
1095
1
1193
1204
1205
1194
1314
1325+
+
1326
1315
CHEXA
1096
1
1194
1205
1206
1195
1315
1326+
+
1327
1316
CHEXA
1097
1
1195
1206
1207
1196
1316
1327+
+
1328
1317
CHEXA
1098
1
1196
1207
1208
1197
1317
1328+
+
1329
1318
CHEXA
1099
1
1197
1208
1209
1198
1318
1329+
+
1330
1319
CHEXA
1100
1
1198
1209
1210
1199
1319
1330+
+
1331
1320
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name information for generic property collectors
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Property Definition for 1-D Elements
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name and color information for generic components
$
$$------------------------------------------------------------------------------$
$HMNAME COMP
6"auto1"
$HWCOLOR COMP
6
3
$
$$
$$------------------------------------------------------------------------------$
$$
Property Definition for Surface and Volume Elements
$
$$------------------------------------------------------------------------------$
$$
$$ PSHELL Data
$
$HMNAME COMP
4"shells"
$HWCOLOR COMP
4
7
PSHELL
4
20.2
2
2
$$
$$ PSOLID Data
$
$HMNAME COMP
1"solids"
$HWCOLOR COMP
1
26
PSOLID
1
1
PFLUID
PSOLID
2
2
$$
$$------------------------------------------------------------------------------$
$$
Material Definition Cards
$
$$------------------------------------------------------------------------------$
$$-------------------------------------------------------------$$ HYPERMESH TAGS
$$-------------------------------------------------------------$$BEGIN TAGS
$$END TAGS
$$
$$ MAT1 Data
$

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

519

$HMNAME MAT
2"MAT1"
$HWCOLOR MAT
2
18
MAT1
2200000.0
0.3
0.9e-5
$$
$$
$$ MAT10 Data
$HMNAME MAT
1"MAT10_1"
$HWCOLOR MAT
1
3
MAT10
11.0
0.01
$$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name information for generic materials
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Material Definition Cards
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Loads and Boundary Conditions
$
$$------------------------------------------------------------------------------$
$$
$$HyperMesh name and color information for generic loadcollectors
$$
$HMNAME LOADCOL
4"SPC"
$HWCOLOR LOADCOL
4
3
$
$HMNAME LOADCOL
6"spcd"
$HWCOLOR LOADCOL
6
4
$
$$
$$
$$
$$
$$ FREQ1 cards
$$
$HMNAME LOADCOL
5"freq"
$HWCOLOR LOADCOL
5
4
FREQ1
50.1
10.0
5
$$
$$
$$
$$
$$
$$ RLOAD2 cards
$$
$HMNAME LOADCOL
2"rload2"
$HWCOLOR LOADCOL
2
5
RLOAD2
2
6
1
0
ACCE
$$
$HMNAME LOADCOL
3"darea"
$HWCOLOR LOADCOL
3
5
RLOAD2
3
3
1
0
LOAD
$$
$$
$$
$$ TABLED1 cards
$$
$HMNAME LOADCOL
1"tab"
$HWCOLOR LOADCOL
1
41
TABLED1
1 LINEAR LINEAR
+
0.0
0.0 1000.0
1.0ENDT
$$
TABLED1
2 LINEAR LINEAR
+
0.0
0.0 1000.0
1.0ENDT
$$
TABLED1
3 LINEAR LINEAR
+
0.0
5.0 1000.0
5.0ENDT

520

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$$ DLOAD cards
$$
$HMNAME LOADCOL
$HWCOLOR LOADCOL
DLOAD
111.0
$$
$$
$$
$$
$$
$$
$$
$$ SPC Data
$$
SPC
4
SPC
4
SPC
4
SPC
4
SPC
4
$$
$$ SPCD Data
$$
SPCD
6
$
$ DAREA Data
$
$$
$$ DAREA Data
$$
DAREA
3
ENDDATA

11"DLOAD11"
11
3
1.0
2

1431
1432
1451
1452
1734

1234560.0
1234560.0
1234560.0
1234560.0
3
0.0

1734

1734

1.0

3.0

3-10.0

ALTDOCTAG "HqTD_ARNMI\S\pMpN13G;5oANN]l[enE7fmSbTJro20LOpNriZFOQfUk]
_`5hfS5ATf6pT7RXMjA3e@k_r^K?GP;?OeEbD0"
ADI0.1.0 2011-05-13T19:57:45 0of1 OSQA
ENDDOCTAG

Comments
1.

Element identification numbers should be unique with respect to all other element
identification numbers.

2.

Grid points G1 through G4 must be given in consecutive order about one quadrilateral
face. G5 through G8 must be on the opposite face with G5 opposite G1, G6 opposite G2,
and so on.

3.

The edge points, G9 to G20 are optional. All or none of them may exist. The corner grid
points cannot be deleted. The edge points should be in the middle third of the edges.

4.

The second continuation is optional.

5.

The face consisting of grid points G1 through G4 and G9 through G12 is assumed to be in
contact with the structure.

6.

The mass is lumped to the face formed by grid points G5 through G8 and G17 through G20
and defined to be in contact with the fluid. The opposite face has no mass contribution
due to the absorber element. Also, the face in contact with the fluid has only

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

521

translational stiffness in the direction normal to the face.


7.

522

This card is represented as a CHACAB8 or CHACAB20 element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHBDYE
Bulk Data Entry
CHBDYE Thermal Surface Element (Element Form)
Description
Defines a surface element for application of thermal boundary condition.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C HBDYE

EID

EID2

SIDE

Field

Contents

EID

Unique surface element identification number. See comments.

(9)

(10)

No default (Integer > 0)


EID2

A heat conduction element identification number. See comments.


No default (Integer > 0)

SIDE

Element side identification number.


No default (1 < Integer < 6)

Comments
1.

EID is unique with respect to other surface element IDs.

2.

EID2 identifies the heat conduction element associated with this surface element.
1D

2D

3D

CBAR
CBEAM
CONROD
CROD

CQUAD4
CQUAD8
CTRIA3
CTIRA6

CHEXA
CPENTA
CPYRA
CTETRA

C onduction elements for heat transfer analysis

3.

All conduction elements that are to have a boundary condition applied must be individually
identified with the application of a surface element entry CHBDYE.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

523

4.

Side conventions for 3D elements:


Sides are numbered consecutively according to the order of the grid point numbers on the
3D element entry. The sides of 3D elements are either quadrilaterals or triangles. For
each element type, the side numbers are shown here:

Side convention for C HEXA element (1st or 2nd order)

Side convention for C PENTA element (1st or 2nd order)

524

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Side convention for C PYRA element (1st or 2nd order)

Side convention for C TETRA element (1st or 2nd order)

5.

Side conventions for 2D elements.


2D elements have one side of type AREA (this is Side 1) and 3 or 4 sides of type LINE.
AREA type: Side 1 is that given by the right hand rule on the shells gird points.
LINE type: The second side (first line) is from grid point 1 to grid point 2, and the
remaining lines are numbered consecutively. The thickness of the line is that of the shell,
and the normal to the line is outward from the shell in the plane of the shell. Note that
midside nodes are ignored in the specification.

6.

Side conventions for 1D elements.


1D elements have one linear side (Side 1) with geometry that is the same as that of the
element and two POINT type sides, corresponding to the two points bounding the linear
element (first grid point side 2; second grid point side 3).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

525

POINT type: Point sides may be used with any linear element. The direction of the
outward normals of these points is in line with the element axis, but pointing away from
the element. The area assigned to these POINT type sides is consistent with the element
geometry.
Boundary conditions (QBDY1) are applied to CHBDYE through reference of the EID.
7.

526

This card is represented as slave3 and slave4 element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
Bulk Data Entry
CHEXA Six-sided Solid Element with Eight or Twenty Grid Points
Description
Defines the connections of the HEXA solid element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C HEXA

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

G13

G14

G15

G16

G17

G18

G19

G20

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C HEXA

71

10

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSOLID property entry.


Default = EID (Integer > 0)

G#

Grid point identification numbers of connection points.


Default = blank (Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

527

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Grid points G1,,G4 must be given in consecutive order about one quadrilateral face.
G5,,G8 must be on the opposite face with G5 opposite G1, G6 opposite G2, and so on.
The edge points, G9 through G20, are optional. If any of the edge points are present,
they all must be used. The second continuation must not be present for the 8-noded
version of this element.
It is recommended that the edge points be placed near the middle of the edge.

C HEXA definition

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G5 with G7. For 20-noded CHEXA, appropriate changes to mid-side node
numbering are also performed. In such cases, the element coordinate system will be built
on the renumbered node sequence.

4.

Stresses are output in the material coordinate system. The material coordinate system is
defined on the referenced PSOLID entry. It may be defined as the basic coordinate
system (CORDM = 0), a defined system (CORDM = Integer > 0), or the element coordinate
system (CORDM = -1).

5.

The element coordinate system for the CHEXA element is defined as follows:
Three intermediate vectors R, S, and T are chosen by the following rules:

528

Joins the centroids of the faces described by the grid points G4, G1, G5, G8
and the grid points G3, G2, G6, G7.

Joins the centroids of the faces described by the grid points G1, G2, G6, G5
and the grid points G4, G3, G7, G8

Joins the centroids of the faces described by the grid points G1, G2, G3, G4
and the grid pints G5, G6, G7, G8.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C HEXA element coordinate systems

The origin of the element coordinate system is at the intersection of these three vectors.
If the vectors do not all intersect at one point, then the average location of the
intersection points is used.
The element z-axis corresponds to the T vector.
The element y-axis is the cross product of the T and R vectors.
The element x-axis is the cross product of the element y-axis and the element z-axis.
6.

This card is represented as a hexa8 or hex20 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

529

CMASS1
Bulk Data Entry
CMASS1 Scalar Mass Connection
Description
Defines a scalar mass element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MASS1

EID

PID

G1

C1

G2

C2

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C MASS1

45

653

Field

Contents

EID

Unique element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Property identification number of a PMASS entry.


Default = EID (Integer > 0)

G1, G2

Geometric grid point or scalar point identification number.


Default = 0 (Integer > 0)

C1, C2

Component number in the displacement coordinate system specified by the


CD entry of the GRID data.
No default (0 < Integer < 6)

530

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point with a displacement that is
constrained to zero.

2.

Scalar points may be used for G1 and/or G2, (with a corresponding C1 and/or C2 of zero
or blank). If only scalar points and/or grounded terminals are involved, it is more efficient
to use the CMASS3 entry.

3.

Element identification numbers should be unique with respect to all other element
identification numbers.

4.

The two connection points (G1, C1) and (G2, C2) must not be coincident. Except in
unusual circumstances, one of them will be a grounded terminal with blank entries for Gi
and Ci.

5.

A scalar point specified on this entry need not be defined on an SPOINT entry.

6.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

7.

Scalar mass elements are ignored in heat transfer analysis.

8.

This card is represented as a spring or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

531

CMASS2
Bulk Data Entry
CMASS2 Scalar Mass Property and Connection
Description
Defines a scalar mass element without reference to a property entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MASS2

EID

G1

C1

G2

C2

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C MASS2

1.1

56

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


M

Value of the scalar mass.


No default (Real)

G1, G2

Geometric grid or identification number.


No default (Integer > 0)

C1, C2

Component number in the displacement coordinate system specified by


the CD entry of the GRID data.
No default (0 < Integer < 6)

532

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding


blank or zero C1 or C2. A grounded terminal is a point with a displacement that is
constrained to zero.

2.

Scalar points may be used for G1 and/or G2, (with a corresponding C1 and/or C2 of zero
or blank). If only scalar points and/or grounded terminals are involved, it is more efficient
to use the CMASS4 entry.

3.

Element identification numbers should be unique with respect to all other element
identification numbers.

4.

This single entry completely defines the element since no material or geometric properties
are required.

5.

The two connection points (G1, C1) and (G2, C2) must be distinct. Except in unusual
circumstances, one of them will be a grounded terminal with blank entries for Gi and Ci.

6.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

7.

Scalar mass elements are ignored in heat transfer analysis.

8.

This card is represented as a spring or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

533

CMASS3
Bulk Data Entry
CMASS3 Scalar Mass Connection to Scalar Points Only
Description
Defines a scalar mass element that is connected only to scalar points.
Format
(1)

(2)

(3)

(4)

(5)

C MASS3

EID

PID

S1

S2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

C MASS3

13

42

62

(5)

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Property identification number of a PMASS entry.


Default = EID (Integer > 0)

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

Comments
1.

S1 or S2, but not both, may be blank or zero, indicating a constrained coordinate.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

534

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

Only one scalar mass element may be defined on a single entry.

4.

A scalar point specified on this entry need not be defined on an SPOINT entry.

5.

Scalar mass elements are ignored in heat transfer analysis.

6.

This card is represented as a spring or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

535

CMASS4
Bulk Data Entry
CMASS4 Scalar Mass Property and Connection to Scalar Points Only
Description
Defines a scalar mass element that is connected only to scalar points, without reference to a
property entry.
Format
(1)

(2)

(3)

(4)

(5)

C MASS4

EID

S1

S2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

C MASS4

23

14.92

(4)

(5)

(6)

(7)

(8)

(9)

(10)

23

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

Scalar mass value.


No default (Real)

S1, S2

Scalar point identification numbers.


Default = 0 (Integer >

Comments
1.

536

S1 or S2, but not both, may be blank or zero, indicating a constrained coordinate. This is
the usual case.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

Only one scalar mass element may be defined on a single entry.

4.

A scalar point specified on this entry need not be defined on an SPOINT entry.

5.

This single entry completely defines the element since no material or geometric properties
are required.

6.

Scalar mass elements are ignored in heat transfer analysis.

7.

This card is represented as a spring or mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

537

CMBEAM
Bulk Data Entry
CMBEAM Beam Element for MBD
Description
Defines a beam element for multi-body dynamics solution sequence without reference to a
property entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MBEAM

EID

MID

GA

GB

X1, G0

Y1

Z1

I1

I2

K1

K2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MBEAM

123

125

0.0

0.0

1.0

5.0

100.0

833.3

833.3

1485.3

Field

Contents

EID

Element identification number.

(10)

(Integer > 0)
MID

Material identification number. See comment 5.


(Integer > 0)

GA, GB

538

Grid point identification number of connection points.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

X1, Y1, Z1

Components of vector v at end A, measured at end A, parallel to the


components of the displacement coordinate system for GA, to
determine (with the vector from end A to end B) the orientation of the
element coordinate system for the BEAM element.
(Real)

G0

Grid point identification number to optionally supply X1, X2, and X3


(Integer > 0). Direction of orientation vector is GA to G0.
(Integer > 0)

Undeformed length along the X-axis of the beam.


(Real)

Area of the beam cross-section.


No default (Real > 0.0)

I1

Area moment inertia in plane 1 about the neutral axis.


No default (Real > 0.0)

I2

Area moment inertia in plane 2 about the neutral axis.


No default (Real > 0.0)

Torsional constant.
(Real > 0.0)

K1, K2

Area factor for shear.


Default = 0.0 (Real)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The X-axis of the beam is always along the line connecting G1 and G2. The Z-axis of the
beam is determined based on the X-axis and the Y-axis provided by G3/X1, Y1, and Z1.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

539

3.

The moments of inertia are defined as follows:

The beam coordinates must be aligned with the principal axes of the cross-section.
4.

The transverse shear stiffness in planes 1 and 2 are (K1)AG and (K2)AG, respectively. If
a value of 0.0 is used for K1 and K2, the transverse shear flexibilities are set to 0.0 (K1
and K2 are interpreted as infinite).

5.

Only MAT1 material definitions may be referenced by this element.

6.

This card is represented as a bar2 element in HyperMesh.

540

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMBEAMM
Bulk Data Entry
CMBEAMM Beam Element for MBD based on Markers
Description
Defines a beam element for multi-body dynamic solution sequence without reference to a
property entry based on markers.
Format
(1)

(2)

(3)

(4)

(5)

C MBEAMM

EID

MID

M1

M2

I1

I2

(6)

(7)

(8)

(9)

(10)

K1

K2

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MBEAMM

123

125

0.0

0.0

1.0

5.0

100.0

833.3

833.3

1485.3

Field

Contents

EID

Element identification number.

(10)

(Integer > 0)
MID

Material identification number.


(Integer > 0)

M1

Marker identification number.


(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

541

Field

Contents

M2

Marker identification number.


(Integer > 0)

Undeformed length along the X-axis of the beam.


(Real)

Area of the beam cross-section.


(Real)

I1

Area moment inertia in plane 1 about the neutral axis.


No default (Real > 0.0)

I2

Area moment inertia in plane 2 about the neutral axis.


No default (Real > 0.0)

Torsional constant.
(Real > 0.0)

K1, K2

Area factor for shear.


Default = 0.0 (Real)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The X-axis of the markers M1 and M2 should always be along the axis of the beam.

3.

The moments of inertia are defined as follows:

The beam coordinates must be aligned with the principal axes of the cross-section.
4.

The transverse shear stiffness in planes 1 and 2 are (K1)AG and (K2)AG, respectively. If
a value of 0.0 is used for K1 and K2, the transverse shear flexibilities are set to 0.0 (K1
and K2 are interpreted as infinite).

5.

This card is represented as a bar element in HyperMesh.

542

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMBUSH
Bulk Data Entry
CMBUSH Bushing Element for MBD
Description
Defines a bushing element without reference to a property entry.
Format
(1)

(2)

C MBUSH

EID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

G1

G2

X1, G3

Y1

Z1

"K"

K1

K2

K3

K4

K5

K6

"B"

B1

B2

B3

B4

B5

B6

"P"

P1

P2

P3

P4

P5

P6

(10)

Example

(1)

(2)

C MBUSH

(3)

(4)

(5)

(6)

(7)

(8)

1.0

0.0

0.0

100

100

100

0.1

0.1

0.1

Field

Contents

EID

Element identification number.

(9)

(10)

(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

543

Field

Contents

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

G3

Grid point identification number to optionally supply X1, Y1, and Z1 in


conjunction with G1.
(Integer > 0)

X1, Y1, Z1

Orientation vector of the bushing.


(Real)

Stiffness specifier.

K1, K2, K3

Translational stiffness.

K4, K5, K6

Rotational stiffness.

Damping specifier.

B1, B2, B3

Translational damping.

B4, B5, B6

Rotational damping.

Preload specifier.

P1, P2, P3

Translational preload.

P4, P5, P6

Rotational preload.

Comments
1.

544

Element identification numbers must be unique with respect to all other element
identification numbers.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMBUSHC
Bulk Data Entry
CMBUSHC Nonlinear Bushing Element for MBD using Curve
Description
Defines a bushing element without reference to a property entry.
Format
(1)

(2)

C MBUSHC

EID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

G1

G2

X1, G3

Y1

Z1

"K"

K1C ID

K2C ID

K3C ID

K4C ID

K5C ID

K6C ID

"B"

B1C ID

B2C ID

B3C ID

B4C ID

B5C ID

B6C ID

"P"

P1

P2

P3

P4

P5

P6

KE

K1EID

K2EID

K3EID

K4EID

K5EID

K6EID

BE

B1EID

B2EID

B3EID

B4EID

B5EID

B6EID

KINT

BINT

Example

(1)

(2)

C MBUSHC

Altair Engineering

(3)

(4)

(5)

(6)

(7)

(8)

(9)

1.0

0.0

0.0

100

100

100

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

545

AKIMA

AKIMA

Field

Contents

EID

Element identification number


(Integer > 0)

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

G3

Grid point identification number to optionally supply X1, Y1, and Z1 in


conjunction with G1.
(Integer > 0)

X1, Y1,
Z1

Orientation vector of the bushing.


(Real)

Stiffness specifier.

K1CID,
K2CID,
K3CID

Translational stiffness curve ID.

K4CID,
K5CID,
K6CID

Rotational stiffness curve ID.

Damping specifier.

B1CID,
B2CID,
B3CID

Translational damping curve ID.

B4CID,
B5CID,

Rotational damping curve ID.

546

Default = 0 (Integer > 0 or blank)

Default = 0 (Integer > 0 or blank)

Default = 0 (Integer > 0 or blank)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

B6CID

Default = 0 (Integer > 0 or blank)

Preload specifier.

P1, P2, P3 Translational preload.


P4, P5, P6 Rotational preload.
K1EID,
K2EID,
K3EID

Translational stiffness independent variable expression ID.

K4EID,
K5EID,
K6EID

Rotational stiffness independent variable expression ID.

B1EID,
B2EID,
B3EID

Translational damping independent variable expression ID.

B4EID,
B5EID,
B6EID

Rotational damping independent variable expression ID.

KINT

Stiffness interpolation type (Character: LINEAR, CUBIC, AKIMA).

Default = 0 (Integer > 0 or blank) implies deflection as the independent


variable

Default = 0 (Integer > 0 or blank) implies deflection as the independent


variable

Default = 0 (Integer > 0 or blank) implies velocity as the independent


variable

Default = 0 (Integer > 0 or blank) implies velocity as the independent


variable

Default = AKIMA
BINT

Damping interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

547

CMBUSHE
Bulk Data Entry
CMBUSHE Nonlinear Bushing Element for MBD using Expression Defined in MBVAR
Description
Defines a bushing element without reference to a property entry.
Format
(1)

(2)

C MBUSHE

EID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

G1

G2

X1, G3

Y1

Z1

"K"

K1EID

K2EID

K3EID

K4EID

K5EID

K6EID

"B"

B1EID

B2EID

B3EID

B4EID

B5EID

B6EID

"P"

P1

P2

P3

P4

P5

P6

Example

(1)

(2)

C MBUSHE

(3)

(4)

(5)

(6)

(7)

(8)

1.0

0.0

0.0

100

100

100

Field

Contents

EID

Element identification number.

(9)

(10)

(Integer > 0)

548

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

G3

Grid point identification number to optionally supply X1, Y1, and Z1 in


conjunction with G1.
(Integer > 0)

X1, Y1, Z1

Orientation vector of the bushing.


(Real)

Stiffness specifier.

K1EID, K2EID,
K3EID

Translational stiffness MBVAR ID.


Default = 0 (Integer > 0 or blank)

K4EID, K5EID,
K6EID

Rotational stiffness MBVAR ID.


Default = 0 (Integer > 0 or blank)

Damping specifier.

B1EID, B2EID,
B3EID

Translational damping MBVAR ID.


Default = 0 (Integer > 0 or blank)

B4EID, B5EID,
B6EID

Rotational damping MBVAR ID.


Default = 0 (Integer > 0 or blank)

Preload specifier.

P1, P2, P3

Translational preload.

P4, P5, P6

Rotational preload.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

549

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

This card is represented as a spring element in HyperMesh.

550

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMBUSHM
Bulk Data Entry
CMBUSHM Bushing Element for MBD based on Markers
Description
Defines a bushing element without reference to a property entry based on markers.
Format
(1)

(2)

C MBUSHM

EID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

M1

M2

"K"

K1

K2

K3

K4

K5

K6

"B"

B1

B2

B3

B4

B5

B6

"P"

P1

P2

P3

P4

P5

P6

(10)

Example

(1)

(2)

C MBUSHM

(3)

(4)

(5)

(6)

(7)

(8)

(9)

12

13

100

100

100

0.1

0.1

0.1

Field

Contents

EID

Element identification number.

(10)

(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

551

Field

Contents

M1

Marker identification number.


(Integer > 0)

M2

Marker identification number.


(Integer > 0)

Stiffness specifier.

K1, K2, K3

Translational stiffness.
(Real)

K4, K5, K6

Rotational stiffness.
(Real)

Damping specifier.

B1, B2, B3

Translational damping.
(Real)

B4, B5, B6

Rotational damping.
(Real)

Preload specifier.

P1, P2, P3

Translational preload.
(Real)

P4, P5, P6

Rotational preload.
(Real)

Comments
1.

552

Element identification numbers must be unique with respect to all other element
identification numbers.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CMBUSHT
Bulk Data Entry
CMBUSHT Nonlinear Bushing Element for MBD using Table
Description
Defines a bushing element without reference to a property entry.
Format
(1)

(2)

(3)

C MBUSHT

EID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

G1

G2

X1, G3

Y1

Z1

"K"

K1TID

K2TID

K3TID

K4TID

K5TID

K6TID

"B"

B1TID

B2TID

B3TID

B4TID

B5TID

B6TID

"P"

P1

P2

P3

P4

P5

P6

Example

(1)

(2)

C MBUSHT

(3)

(4)

(5)

(6)

(7)

(8)

1.0

0.0

0.0

100

100

100

Field

Contents

EID

Element identification number.

(9)

(10)

(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

553

Field

Contents

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

G3

Grid point identification number to optionally supply X1, Y1, and Z1 in


conjunction with G1.
(Integer > 0)

X1, Y1, Z1

Orientation vector of the bushing.


(Real)

Stiffness specifier.

K1TID, K2TID,
K3TID

Translational stiffness TABLEDi ID.


Default = 0 (Integer > 0 or blank)

K4TID, K5TID,
K6TID

Rotational stiffness TABLEDi ID.


Default = 0 (Integer > 0 or blank)

Damping specifier.

B1TID, B2TID,
B3TID

Translational damping TABLEDi ID.


Default = 0 (Integer > 0 or blank)

B4TID, B5TID,
B6TID

Rotational damping TABLEDi ID.


Default = 0 (Integer > 0 or blank)

Preload specifier.

P1, P2, P3

Translational preload.

P4, P5, P6

Rotational preload.

554

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

555

CMSMETH
Bulk Data Entry
CMSMETH Component Mode Synthesis Method Definition
Description
CMSMETH defines the CMS method, frequency upper limit, number of modes, and starting
SPOINT ID to be used in a component mode synthesis solution. The eigenvalue solver is also
specified. In addition, preload as well as loads for reduction and residual vector generation
can be defined. Also, an ASCII file containing CELAS4 and CDAMP3 element data and/or their
corresponding design variable definitions can be generated for DMIG to allow the use of the
component modes in optimization runs.
Format
(1)

(2)

(3)

C MSMETH C MSID METHOD

(4)

(5)

(6)

(7)

(8)

(9)

UB_FRE
Q

NMODES

SPID

SOLVER

AMPFFA
CT

SHFSC L

UB_FRE
Q_F

NMODES
_F

SPID_F

GPRC

(8)

(9)

(10)

Optional continuation lines for preload definition


(1)

(2)

(3)

(4)

PRELOAD

SPC ID

PLSID

(5)

(6)

(7)

(10)

Optional continuation lines for LOAD SET definition


(1)

(2)

(3)

LOADSET USETYPE

(4)

(5)

(6)

LSID1

LSID2

LSID3

(7)

(8)

(9)

(10)

Optional continuation lines for DMIGDV definition


(1)

556

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DMIGDV

S/F

OUTOPT

NMODE

DVKUPFAC

DVGEUP

DVBUP

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

Example

(1)

(2)

(3)

(4)

(5)

(6)

C MSMETH

C BN

1000

200

100000

600

100

200000

Field

Contents

CMSID

CMSMETH identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
METHOD

Component mode synthesis method to be employed. See comment 2.


No default (Character = CB, CC, CBN, GM, or GUYAN)

UB_FREQ

Upper bound frequency for the eigenvalue analysis for the structural part.
If 0.0 or blank, no upper bound is used. See comments 3 and 4.
Default = blank (Real > 0.0, or blank)

NMODES

Number of modes to be extracted from structural eigenvalue analysis. If


set to -1 or blank, number of modes is limitless. See comments 3 and 4.
Default = blank (Integer > -1, or blank)

SPID

The starting SPOINT ID to be used in DMIG matrix output for the


structural eigenmodes.
No default. See comment 6.

SOLVER

The eigenvalue solver. Either blank or LAN for Lanzos. AMSES for
AMSES.
Default = LAN (Character = LAN or AMSES, or blank)

AMPFFACT

AMSES Amplification Factor. The substructure modes are solved up to


the frequency of AMPFFACT*V2. Higher values of AMPFFACT will lead to
more accurate results and longer running times. See comment 9.
Default = 5.0 (Real or blank)

SHFSCL

For vibration analysis, it is the estimate of the frequency of the first


flexible mode. See comment 12.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

557

Field

Contents
Default = blank (Real or blank)

UB_FREQ_F

Upper bound frequency for the eigenvalue analysis for the fluid part. If
0.0 or blank, no upper bound is used. See comments 3 and 4.
Default = blank (Real > 0.0, or blank)

NMODES_F

Number of modes to be extracted from fluid eigenvalue analysis. If set to


-1 or blank, number of modes is limitless. See comments 3 and 4.
Default = blank (Integer > -1, or blank)

SPID_F

The starting SPOINT ID to be used in DMIG matrix output for the fluid
eigenmodes.
No default. See comment 6.

GPRC

Grid participation recovery control.


Allows fluid-structure interface grid shape data (that is the modes
associated with the fluid-structure interface) to be calculated and stored
with the external superelement.
Only applicable when GM (general modal formulation) is input in the
METHOD field and when all boundary degrees of freedom are free
(BNDFREE).
If any boundary degrees of freedom are fixed and GPRC is set to YES, the
program will be terminated with an error.
Default = NO (YES, NO)

PRELOAD

PRELOAD flag indicates that a preload will be used in the CMS analysis

SPCID

SPC SET ID for the preload

PLSID

LOAD SET ID for defining the preload.

LOADSET

LOADSET flag indicates that static load sets will be used in CMS analysis.

USETYPE

RESVEC/REDLOAD/BOTH defines the use type for the load sets


RESVEC the load set is used for generating residual vectors to improve
the modal space
REDLOAD the load set is used for generating reduced loads
BOTH both RESVEC and REDLOAD options are selected
Default = BOTH (see comment 11)

558

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

LSIDi

The load set IDs for generating residual vectors and/or reduced loads.

S/F

S Selects the structural part of the model.


Default = S

DMIGDV

DMIGDV flag indicates that an ASCII file containing CELAS4 and CDAMP3
element data and/or their corresponding design variable definitions is
generated for DMIG (see comment 13).

OUTOPT

OUTOPT defines how design variable definitions are written for DMIG.
(see comments 13 to 17) If OUTOPT is:
1 Only CELAS4 and CDAMP3 element data and PDAMP properties (if
any) are written. Design variable definitions are not written.
2 All data from Option-1 and design variable definitions are written
(Default, see comment 14).
3 All data from Option-2 and constraint (f1<f2) creation data are
written (see comment 15).
If OUTOPT field is blank then Option-2 is the default.

NMODE

NMODE defines the number of design variables for K/GE and B in


CELAS4 and CDAMP3 (see comment 18).
If NMODE > 0 then NMODE number of design variables will be written to
control the first NMODE eigenvalue changes (K), damping coefficient
changes (GE) and scalar damping value changes (B).
If NMODE is not specified (the NMODE field is blank) then as many design
variables as the total number of modes are written.

DVKUPFAC

DVKUPFAC is used to determine the upper bound of K (which is


(maximum eigenvalue)*DVKUPFAC). If DVKUPFAC is not specified
(DVKUPFAC field is blank) then it is set to 0.1 by default (See comment
16).
Default: DVKUPFAC=0.1

DVGEUP

Upper bound of GE. This applies to all the design variables for GE. If
DVGEUP is not specified (DVGEUP field is blank) then it is set to 2*DVBUP
by default (See comment 16).
Default: DVGEUP=2*DVBUP

DVBUP

Upper bound of B. This applies to all the design variables for B. If


DVBUP is not specified (DVBUP field is blank) then it is set to 0.4 by

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

559

Field

Contents
default (See comment 16).
Default: DVBUP=0.4

Comments
1.

This definition will be ignored unless referenced in the I/O Options section by a CMSMETH
run control.

2.

Several methods are available for Component Mode Synthesis, these are: CB, CC, CBN,
GM and GUYAN (see descriptions below).
The first two methods (CB and CC) are used for generating flexible bodies for use with
multi-body dynamics analysis software, such as Altairs MotionSolve.
The remaining methods (CBN, GM and GUYAN) are used primarily to generate external
superelements (stored in DMIG format) for use in subsequent finite element analyses.
Flexible body methods:
CB Craig-Bampton formulation
CC Craig-Chang formulation
External superelement methods:
CBN Craig-Bampton Nodal formulation
GM General Modal formulation
GUYAN GUYAN reduction:
GUYAN is the same as CBN without including structural eigenmodes; when GUYAN is used,
UB_FREQ & NMODES are ignored.

3.

UB_FREQ, NMODES, UB_FREQ_F and NMODES_F cannot all be blank. Additionally, when
structural elements are present in the model, UB_FREQ and NMODES cannot both be
blank, and when fluid elements are present in the model, UB_FREQ_F and NMODES_F
cannot both be blank.

4.

When UB_FREQ = 0.0 and NMODES = 0, this is a special case where no structural
eigenmodes will be included in CMS mode generation. If both UB_FREQ and NMODES are
specified, lowest NMODES below UB_FREQ will be accepted as structural SPOINTs.
Similarly things are applied to fluid part.

5.

If PARAM, EXTOUT, DMIGPCH (or DMGBIN) is defined when using the CB method, then a
DMIG matrix corresponding to the reduced stiffness and mass matrices will be output.
The stiffness and mass corresponding to the eigenmodes will be assigned to the
generated SPOINTs.

6.

The SPOINT IDs of the structure and fluid should have distinct IDs. Any fluid SPOINT ID
cannot be in between structural SPOINT IDs.

7.

When PARAM,EXTOUT is used to output DMIG matrices, then it is possible to disable the

560

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

output of a flexh3d file by specifying OUTPUT,H3D,NONE in the input file.


8.

The nodal flexh3d file output from the CBN method can be used as the DMIG input (using
ASSIGN,H3DDMIG). In this way, the model set output in flexh3d file will be recovered as
the interior points of the DMIG matrix in the residual structure run. The displacements of
these interior points will be included in the output.

9.

AMPFFACT is used to increase the accuracy of the eigenvalue and eigenvectors at the
expense of slightly longer run times. It is recommended to use higher values of
AMPFFACT for solid structures like engine blocks and suspension components. If
AMPFFACT is not specified by you and the model contains a large number of solid
elements, then the value of AMPFFACT is automatically reset to 10.

10. The mass properties of the super element (Mass, Center of Gravity, and Moments of
Inertia) are written to the H3D file. In the residual run, these mass properties are
included in the mass properties of the structure printed in the .out file.
11. The USETYPE field should always be set to BOTH or blank for flexible body generation
(METHOD=CB or CC, see comment 2).
12. A specification of SHFSCL may improve the performance of a vibration analysis.
13. If you define the DMIGDV optional continuation card, a text file (ASCII)
filename_dmig_dv.inc is created after the run. You can include this file in the original
input deck to study how changes in the eigenvalues/damping of superelements affect the
performance of the residual structure.
14. In addition to the data included in option 1, the ASCII file now also contains design
variable definitions. These design variables can control available eigenvalues, structural
damping, and viscous damping of the superelement. You can set up an optimization
problem by including this file in the original input deck.
15. In addition to the data included in option 2, the ASCII file now includes data required for
the creation of constraints. These constraints ensure that the eigenvalue of the nth
mode is less than the eigenvalue of the (n+1)th mode during optimization.
16. The lower bound of K, B and GE is set such that K, B and GE are always greater than
or equal to zero.
17. The DMIGDV continuation line works only for METHOD = GM (General Modal formulation) in
field 3 of CMSMETH (See comment 2).
18. Where, K, GE and B represent increments/decrements to the eigenvalues (K), damping
coefficients (GE) and scalar damping values (B) respectively. You are required to include
the .h3d file containing the values of K, GE and B using ASSIGN, H3DDMIG.
19. For further information on creating flex bodies for third party software, refer to Coupling
OptiStruct with Third Party Software in the Users Guide.
20. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

561

CMSPDP
Bulk Data Entry
CMSPDP Multi-body Spring Damper Element
Description
Defines a spring damper element without reference to a property entry for multi-body solution
sequence.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MSPDP

EID

G1

G2

PF

TYPE

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MSPDP

34.5

223

324

0.0

1.0

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

TRANS

(Integer > 0)
K

Stiffness value.
Default = 0.0 (Real or blank)

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

562

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Damping value.
Default = 0.0 (Real or blank)

Unstretched length/angle of spring damper. See comment 4.


Default = 0 (Real > 0.0 or blank)

PF

Preload force.
Default = 0 (Real or blank)

TYPE

Type
(TRANS or ROT; if blank, default: TRANS)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The spring damper force is along the line segment connecting the grids G1 and G2.

3.

The positive preload force is a stretching force.

4.

If the unstretched length/angle of spring damper field (L) is blank:


(a) For a translational spring, OptiStruct calculates the length between the two grid
points (G1, G2) of the spring damper for the value of L.
(b) For a rotational spring, L is set to 0.0.

5.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

563

CMSPDPC
Bulk Data Entry
CMSPDPC Nonlinear Multi-body Spring Damper Element using Curve
Description
Defines a spring damper element without reference to a property entry for multi-body solution
sequence.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MSPDPC

EID

KC ID

G1

G2

BC ID

PF

TYPE

KINT

KEID

BINT

BEID

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MSPDPC

34

223

324

1.0

AKIMA

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

TRANS

(Integer > 0)
KCID

Stiffness curve ID.


Default = 0 (Integer > 0 or blank)

G1

Grid point identification number.


(Integer > 0)

564

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

G2

Grid point identification number.


(Integer > 0)

Damping Curve ID.


Default = 0 (Integer > 0 or blank)

Unstretched length of spring damper.


Default = 0 (Real > 0.0 or blank)

PF

Preload force.
Default = 0 (Real or blank)

TYPE

Type.
(TRANS or ROT; if blank, default: TRANS)

KINT

Stiffness Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

KEID

MBVAR ID for independent variable ID for stiffness.


Default = Deflection (Integer > 0 or blank)

BINT

Damping Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

BEID

MBVAR ID for independent variable ID for damping.


Default = Velocity (Integer > 0 or blank)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The spring damper force is along the line segment connecting the grids, G1 and G2.

3.

The positive preload force is a stretching force.

4.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

565

CMSPDPE
Bulk Data Entry
CMSPDPE Nonlinear Multi-body Spring Damper Element using Expression defined in MBVAR
Description
Defines a spring damper element without reference to a property entry for multi-body solution
sequence.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MSPDPE

EID

KEID

G1

G2

BEID

PF

TYPE

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MSPDPE

223

324

1.0

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

TRANS

(Integer > 0)
KEID

MBVAR ID for stiffness expression.


Default = 0 (Integer > 0 or blank)

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

566

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

BEID

MBVAR ID for Damping expression.


Default = 0 (Integer > 0 or blank)

Unstretched length of spring damper.


Default = 0 (Real > 0.0 or blank)

PF

Preload force.
Default = 0 (Real or blank)

TYPE

Type.
(TRANS or ROT; if blank, default: TRANS)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The spring damper force is along the line segment connecting the grids G1 and G2.

3.

The positive preload force is a stretching force.

4.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

567

CMSPDPM
Bulk Data Entry
CMSPDPM Multi-body Spring Damper Element based on Marker
Description
Defines a spring damper element without reference to a property entry for multi-body solution
sequence based on marker.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C MSPDPM

EID

M1

M2

PF

TYPE

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MSPDPM

34.5

223

324

0.0

1.0

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

TRANS

(Integer > 0)
K

Stiffness value.
Default = 0.0 (Real or blank)

M1

Marker identification number.


(Integer > 0)

M2

Marker identification number.


(Integer > 0)

568

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Damping value.
Default = 0.0 (Real or blank)

Unstretched length of spring damper.


Default = 0 (Real > 0.0 or blank)

PF

Preload force.
Default = 0 (Real or blank)

TYPE

Type.
(TRANS or ROT; if blank, default: TRANS)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The spring damper force is along the line segment connecting the marker M1 and M2.

3.

The positive preload force is a stretching force.

4.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

569

CMSPDPT
Bulk Data Entry
CMSPDPT Nonlinear Multi-body Spring Damper Element using Table
Description
Defines a spring damper element without reference to a property entry for multi-body solution
sequence.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C MSPDPT

EID

KTID

G1

G2

BTID

PF

TYPE

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C MSPDPT

223

324

1.0

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

TRANS

(Integer > 0)
KTID

TABLEDi ID for stiffness.


Default = 0 (Integer > 0 or blank)

G1

Grid point identification number.


(Integer > 0)

G2

Grid point identification number.


(Integer > 0)

570

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

BTID

TABLEDi ID for Damping.


Default = 0 (Integer > 0 or blank)

Unstretched length of spring damper.


Default = 0 (Real > 0.0 or blank)

PF

Preload force.
Default = 0 (Real or blank)

TYPE

Type.
(TRANS or ROT; if blank, default: TRANS)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The spring damper force is along the line segment connecting the grids G1 and G2.

3.

The positive preload force is a stretching force.

4.

This card is represented as a spring element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

571

CONM1
Bulk Data Entry
CONM1 Concentrated Mass Element Connection, General Form
Description
Defines a 6x6 mass matrix at a geometric grid point.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ONM1

EID

C ID

M11

M21

M22

M31

M32

M33

M41

M42

M43

M44

M51

M52

M53

M54

M55

M61

M62

M63

M64

M65

M66

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

C ONM1

22

2.9

6.3

4.8

28.6

(7)

(8)

28.6

Field

Contents

EID

Unique element identification number.

(9)

(10)

28.6

(Integer > 0)
G

Grid point identification number.


(Integer > 0)

572

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

CID

Coordinate system identification number for the mass matrix.


(Integer > 0)

Mij

Mass matrix values.


(Real)

Comments
1.

This card is represented as a mass element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

573

CONM2
Bulk Data Entry
CONM2 Concentrated Mass Element Connection, Rigid Body Form
Description
Defines a concentrated mass at a grid point of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C ONM2

EID

C ID

X1

X2

X3

I11

I21

I22

I31

I32

I33

(9)

(10)

Example

(1)

(2)

(3)

C ONM2

15

16.2

(4)

(5)

(6)

(7)

(8)

(9)

(10)

49.7

16.2

Field

Contents

EID

Unique element identification number.

7.8

No default (Integer > 0)


G

Grid point identification number.


No default (Integer > 0)

CID

Coordinate system identification number.


Default = 0 (Integer > -1)

574

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Mass value.
No default (Real)

X1, X2, X3

Offset distance from the grid point to the center of gravity of the mass
in the coordinate system defined by CID, unless CID = -1, in which case
X1, X2, and X3 are the coordinates (not offsets) of the center of gravity
of the mass in the basic coordinate system.

Iij

Mass moments of inertia measured at the mass c.g.


If CID is zero, then Iij is defined in the basic coordinate system.
If CID > 1, then Iij refers to the local coordinate system.
If CID is -1, then Iij refers to the basic coordinate system.
Default = 0.0 (Real)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

If the continuation is omitted, all rotary inertia is assigned zero values.

3.

The form of the inertia matrix about its c.g. is taken as:

where M =

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

575

and X1, X2, and X3 are components of distance from the c.g. The negative signs for the
off-diagonal terms are supplied by the program.
4.

If CID = -1, then the offsets are computed internally as the difference between the grid
point location and X1, X2, and X3. The grid points may be defined in a local coordinate
system, in which case the values of
basic coordinate system.

must be in a coordinate system that parallels the

5.

If CID > 0, then X1, X2, and X3 are defined by a local Cartesian system, even if CID
references a spherical or cylindrical coordinate system.

6.

This card is represented as a mass element in HyperMesh.

576

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CONNECT
Bulk Data Entry
CONNECT Connects two parts
Description
The CONNECT bulk data entry can be used to define equivalence for all degrees of freedom of
grid points of two different parts within a specified tolerance. The tolerance is defined as the
maximum distance between two grid points within which equivalence is allowed. Two formats
can be used to either select all grid points or a few grid points for equivalence.
Format
(1)

(2)

(3)

(4)

C ONNEC T name_a name_b

(5)

(6)

(7)

(8)

(9)

(10)

tol

Example

(1)

(2)

(3)

(4)

(5)

C ONNEC T

C yl_Head

Gaskt

0.01

(6)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

C ONNEC T

name_a

name_b

tol

GRID

GID1

GID2

(5)

(6)

(7)

(8)

GID3

...

GIDn

(9)

(10)

Alternate Example

(1)

(2)

C ONNEC T C yl_Head

Altair Engineering

(3)

(4)

Gaskt

0.01

(5)

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

577

GRID

1201

1212

192

115

Field

Contents

name_a

Name of a part selected for equivalencing. Part name_a is the reference


part. All grid points in part name_a are considered during the search; if
OptiStruct finds grid points in part name_b within the specified maximum
distance (tol), then such grid point pairs are equivalent.
(Character String)

name_b

Name of a part selected for equivalencing. All grid points in part name_a are
considered during the search; if OptiStruct finds grid points in part name_b
within the specified maximum distance (tol), then such grid point pairs are
equivalent.
(Character String)

tol

Specifies the numeric value defining the maximum distance between two grid
points to allow equivalence. All grid points in part name_a are considered
during the search; if OptiStruct finds grid points in part name_b within the
specified maximum distance (tol), then such grid point pairs are equivalent.
(Real > 0.0)

GRID

GRID flag indicating that a list of grid point IDs is to follow. These grid point
locations are used to define locations to search for matching nodes.

GID#

Identification numbers of grid points that define locations at which a search


for matching nodes is conducted. GID# do not need to belong to either part
name_a or part name_b.
(Integer > 0)

Comments
1.

Parts can be connected in two different ways, using the CONNECT entry or by using rigid
elements. The RELOC and INSTNCE entries can be used to position the part appropriately
within the full model and the CONNECT entry or rigid elements can be used to connect the
requisite number of grid points of one part to the other.

2.

In an alternate form, grid point IDs can be specified anywhere in the model, it is not
mandatory for a grid point ID to belong to a part. Equivalencing takes place between any
matching grids in both parts if they coincide with the location of any grid in the list.

3.

Searches defined by this entry are performed after all parts are located at their final
positions.

578

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CONROD
Bulk Data Entry
CONROD Rod Element Property and Connection
Description
Defines a rod element without reference to a property entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C ONROD

EID

G1

G2

MID

NSM

Example

(1)

(2)

(3)

(4)

(5)

(6)

C ONROD

16

17

269

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
G1,G2

Grid point identification numbers of connection points.

MID

Material identification number. See comment 1.


(Integer > 0)

Area of the rod.


(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

579

Field

Contents

Torsional constant.
(Real)

Coefficient for torsional stress determination.


(Real)

NSM

Nonstructural mass per unit length.


(Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

C ONROD Element Forces and Moments

2.

580

This card is represented as a rod element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CONTACT
Bulk Data Entry
CONTACT Contact Interface Definition
Description
Defines a contact interface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C ONTAC
T

C TID

PID/
TYPE/
MU1

SSID

MSID

MORIENT

SRC HDI
S

ADJUST

C LEARANC E

DISC RET

Example

(1)

(2)

(3)

(4)

(5)

C ONTAC T

SLIDE

(6)

(7)

(8)

(9)

(10)

N25

Field

Contents

CTID

Contact interface identification number.


(Integer > 0)

PID

Property identification number of a PCONT, PCONTX entry.


(Integer > 0)

TYPE

Choose type of contact without pointing to contact property


respective default property settings will be used. Default settings can be
changed using CONTPRM.
SLIDE Sliding contact.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

581

Field

Contents
STICK Contact with stick condition (stick applies to closed contacts
only).
FREEZE Enforced zero relative displacements on the contact interface
(applies to both closed and open contacts). See comments 5 and 15.
Default = SLIDE (SLIDE, STICK, FREEZE)

MU1

Coefficient of static friction (s). See comment 6.


(0.0 < Real < 1.0)

SSID

Identification number of slave entity. See comments 2 and 14.


(Integer > 0)

MSID

Identification number of master entity. See comments 3 and 15.


(Integer > 0)

MORIENT

Orientation of contact pushout force from master surface. This only


applies to masters that consist of shell elements or patches of grids.
Masters defined on solid elements always push outwards irrespective of
this flag.
OPENGAP The contact interface is assumed open.
OVERLAP Slave and master bodies overlap.
NORM Contact force is oriented along the vector normal to the master
surface.
REVNORM Contact force is oriented opposite to the default vector
normal to the master surface.
Default = OPENGAP (OPENGAP, OVERLAP, NORM or REVNORM). See
comments 7, 8, and 17.

SRCHDIS

Search distance criterion for creating contact condition. When specified,


only slave nodes that are within SRCHDIS distance from master surface
will have contact condition checked.
Default = twice the average edge length on the master surface. For
FREEZE contact, half the average edge length. (Real > 0 or blank)

ADJUST

Adjustment of slave nodes onto the master surface at the start of a


simulation.
<NO, AUTO, Real > 0.0, or Integer > 0>

582

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = NO.
NO no adjustment.
AUTO A real value equal to 5% of the average edge length on the
master surface is internally assigned as the depth criterion (see comment
10).
Real > 0.0 value of the depth criterion which defines the zone in
which a search is conducted for slave nodes (for which contact elements
have been created). These slave nodes (with created contact elements)
are then adjusted onto the master surface. The assigned depth criterion
is used to define the searching zone in the pushout direction (see
comment 10).
Integer > 0 identification number of a SET entry with TYPE = GRID.
Only the nodes on the slave entity which also belong to this SET will be
selected for adjustment.
Note: See comment 10 for more information.

CLEARANCE Prescribed initial gap opening between master and slave, irrespective of
the actual distance between the nodes (see comment 11).
Default = blank (Real or blank)
DISCRET

Discretization approach type for the construction of contact elements.


<N2S, S2S>
Default = N2S.
N2S node-to-surface discretization
S2S surface-to-surface discretization

Comments for nonlinear quasi-static analysis


1.

If the node-to-surface (DISCRET=N2S) discretization approach is selected, the CONTACT


interface is constructed by searching, for each slave node, a respective facet of the
master surface, which contains the normal projection of the slave and is within SRCHDIS
distance from the slave node. If no master segment with normal projection is found, then
the nearest segment is picked if the direction from slave to master is within a certain
angle (30 degrees) relative to the normal to the master segment. Having found a feasible
master segment for the slave node, a contact element is created of a similar structure as
the CGAPG element (Figure 1).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

583

Figure 1: C reation of a contact element

If the surface-to-surface (DISCRET=S2S) discretization approach is selected, the


CONTACT interface is constructed by searching, for each facet of the slave surface,
respective facets of the master surface which contain the normal projection of sample
points on the slave facet and is within SRCHDIS distance from the sample points. For a
slave node, a contact element is created with the surrounding slave facets and the
master facets found by projection of the sample points on the slave facets (Figure 2).

Figure 2: C reation of a contact element (surface-to-surface discretization)

2.

The slave entity (SSID) always consists of grid nodes. It may be specified as:
a set of grid nodes defined using SET(GRID,..) command.
a surface defined using SURF command (the slave nodes are picked from the
respective nodes of the SURF faces).
a set of elements (shells or solids) defined using SET(ELEM,..) command. Slave nodes
are picked from the respective nodes of the elements in the set. For 3D solids, only
nodes on the surface of the solid body are selected; internal nodes are not considered.
DISCRET = N2S is recommended if the slave entity is a set of grids (nodes) or a set of
solid elements.

3.

The master entity (MSID) may be defined as:


a surface defined using SURF command.

584

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

a set of elements (shells or solids) defined using SET(ELEM,..) command. For sets of
3D solids, element faces on the surface are automatically found and selected as
master surface.
4.

Prescribing TYPE=STICK is interpreted in OptiStruct as an enforced stick condition - such


contact interfaces will not enter the sliding phase. Of course, the enforced stick only
applies to contacts that are closed. Note that, in order to effectively enforce the stick
condition, frictional offset may need to be turned off (See comment 8 on PCONT).

5.

Prescribing TYPE=FREEZE enforces zero relative motion on the contact surface the
contact gap opening remains fixed at the original value and the sliding distance is forced
to be zero. Also, rotations at the slave node are matched to the rotations of the master
patch. The FREEZE condition applies to all respective contact elements, no matter
whether open or closed.

6.

Prescribing MU1 directly on the CONTACT card allows for simplified specification of
frictional contacts. Note that this implies MU2=MU1, unless MU2 is specified explicitly on
the CONTPRM card. Also note that the value of MU1 prescribed on the CONTACT card
must be less than 1.0 to specify higher values of static coefficient of friction, PCONT
card must be used.
If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

7.

MORIENT defines the master pushout direction, which is the direction of contact force
that master surface exerts on slave nodes.
It is important to note that, in most practical applications, leaving this field blank will
provide correct resolution of contact, irrespective of the orientation of surface normals.
Only in cases of master surfaces defined as shells or patches of grids, and combined with
initial pre-penetration, is MORIENT needed.
By default, MORIENT is ignored for solid elements it applies only to master surfaces that
consist of shell elements or patches of grids. (Master surfaces defined as faces of solid
elements always push outwards, irrespective of the surface normals, or whether the
contact gap is initially open or closed. See comment 7 for additional options).
a) In default behavior (OPENGAP), the pushout direction is defined using the assumption
that the gap between slave and master is initially open, and the contact condition
should prevent their contact (gap padding GPAD from the PCONT card is ignored in
defining the pushout direction this direction is based strictly on the positions of
master and slave nodes).
The following example shows a typical use of OPENGAP:

Figure 3: Example for the use of OPENGAP

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

585

b) OVERLAP assumes the reverse, namely that the slave and master bodies are already
overlapping and the contact condition should push them apart (this is useful in case of
pre-penetrating models when the entire slave set is pre-penetrating into the master
object).
The following example shows a typical use of OVERLAP:

Figure 4: Example for the use of OVERLAP

c) With the NORM option, the pushout force is oriented along the normal vector to the
master surface. (Note that the surface normal may be reversed relative to the default
normal to a shell element if a FLIP flag is present on the master SURF definition. This
behavior corresponds to that of the reverse normals checkbox on the contactsurfs
panel in HyperMesh). In cases when the slave node does not have a direct normal
projection onto the master surface, and the "shortest distance" projection is used
(GAPGPRJ set to SHORT on the GAPPRM card), the pushout force is oriented along the
shortest distance line, yet with the orientation aligned with the normal vector.
The following example shows a typical use of NORM:

Figure 5: Example for the use of NORM

d) REVNORM creates pushout force reversed relative to the NORM option.


8.

By default, MORIENT does not apply to masters that are defined on solid elements such
masters always push outwards. This can be changed by choosing
CONTPRM,CORIENT,ONALL which extends the meaning of MORIENT to all contact
surfaces. In which case, it should be noted that the default normal is pointing inwards
unless a FLIP flag appears on the master SURF definition for surfaces on solid elements,
making the surface normal point outwards. (When creating contact surfaces in
HyperMesh, this behavior corresponds to that of the reverse normals checkbox on the
contactsurfs panel).

9.

Presently one CONTACT element is created for each slave node. This assures reasonably
efficient numerical computations without creating an excessive number of contact
elements. However, this may require special handling in some cases, such as when a
master surface wraps around the slave set. In such cases, switching the role of slave
and master may be recommended. Alternatively, multiple CONTACT interfaces can be

586

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

created in order to cover all possible directions of relative motion (a simplified illustration
is shown in the figure below). Additionally, individual GAP(G) elements can be used to
handle such special situations.

Figure 6: Special case - Master surface wraps around a slave node set

10. The adjustment of slave nodes doesnt create any strain in the model. If DISCRET=N2S is
selected, it is treated as a change in the initial model geometry. If DISCRET=S2S is
selected, it is treated as a change in the initial contact opening/penetration.
If a node on the slave entity lies outside the projection zone of the master surface, it will
always be skipped during adjustment since no contact element has been constructed for
it.
Contact interface padding will be accounted for during the nodal adjustment. If the
MORIENT field is OPENGAP or OVERLAP while the GPAD field in the referred PCONT
entry is NONE or zero, the nodal adjustment will be skipped, since for OPENGAP or
OVERLAP there is no way to decide the master pushout direction if slave nodes are
adjusted to be exactly on the master face.
If different contact interfaces involve the same nodes, nodal adjustment definitions are
processed sequentially in the order of identification numbers of the contact interfaces.
Care must be taken to avoid conflicts between the nodal adjustments; otherwise, contact
element errors or lack of compliance may occur.
a) The ADJUST field must be set to NO for self-contact.
b) If a real value (the searching depth criterion for adjustment) is input for the ADJUST
field, a searching zone for adjustment is defined. The slave nodes in this searching zone,
for which contact elements have been created, will be adjusted. If ADJUST is larger
than or equal to SRCHDIS, all the slave nodes for which contact elements have been
created, will be adjusted.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

587

Figure 7: An illustration depicting how ADJUST works.

Depth Criterion
The depth criterion (A non-negative real value for ADJUST) is used to define the searching
zone for adjustment, as shown in Figure 7. This searching zone is created in the pushout
direction up to a distance equal to the value of the ADJUST field. The slave nodes within
the searching zone (with defined contact elements) are then considered for adjustment
based on the rules specified within this comment (Comment 10).
c) If the ADJUST field is set to an integer value (the identification number of a grid SET
entry), the nodes shared by the slave entity and the grid SET will be checked for
contact creation, that is, SRCHDIS will be ignored for these nodes, and then adjusted if
a projection is found. The nodes belonging to the grid SET but not to the slave entity
will be simply ignored.
11. Using CLEARANCE overrides the default contact behavior of calculating initial gap opening
from the actual distance between Slave and Master. CLEARANCE is now equal to the
distance that Slave and Master have to move towards each other in order to close the
contact. Negative value of CLEARANCE indicates that the bodies have initial prepenetration.
Warning:

588

If CLEARANCE is used, it is important to correctly restrict the contact zones


and pick search distance SRCHDIS so that only desired Slave-Master pairs are
involved. Using CLEARANCE, all contact elements created on a given
interface, even those where Slaves are geometrically distant from the

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

respective Master surface, will be considered to be at given initial gap and


participate in resolving the contact condition.
Note:
1.

CLEARANCE cannot be used in conjunction with PID of PCONT entry. In such a case,
clearance must be specified on the PCONT entry.

2.

The CLEARANCE field value on the CONTACT entry will be ignored for
ANALYSIS=NLGEOM subcases

Comments for geometric nonlinear analysis (ANALYSIS = NLGEOM subcases)


12. CONTACT models an interface between a master surface and a set of slave grid points. A
grid point can be at the same time as a slave and a master node. Each slave grid point
can impact each master segment; except if it is connected to the impacted master
segment. A grid point can impact on more than one segment. A grid point can impact on
the two sides, on the edges, and on the corners of each segment. The contact uses a
fast search algorithm without limitations.
The main limitations of this interface follow: a) the time step in an explicit analysis is
reduced in case of high impact speed or contacts with small gap; b) the contact may not
work properly if used with a rigid body at high impact speed or rigid body with small gap;
c) the contact does not solve edge to edge contact.
13. Additional control can be applied to the CONTACT definition in geometric nonlinear
subcases through CONTPRM and PCONTX. These definitions are ignored in all other
subcases. A geometric nonlinear subcase is one that has an ANALYSIS = NLGEOM entry
in the subcase definition.
14. The slave entity (SSID) always consists of grid nodes. It may be specified as:
a set of grid nodes defined using SET(GRID,..) command.
a surface defined using SURF command (the slave nodes are picked from the
respective nodes of the SURF faces).
a set of elements (shells or solids) defined using SET(ELEM,..) command. Slave nodes
are picked from the respective nodes of the elements in the set. For 3D solids, only
nodes on the surface of the solid body are selected; internal nodes are not considered.
15. The master entity (MSID) may be defined as:
a surface defined using SURF command.
a set of elements (shells or solids), TYPE = FREEZE is implemented as a TIE kinematic
condition for large deformation subcases.
16. For implicit analysis, modified settings that improve the contact convergence are
recommended. See CONTPRM and PCONTX.
17. This card defined using SET(ELEM,..) command.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

589

Comment for Contact-based Thermal Analysis


18. Thermal-structural analysis problems involving contact are fully coupled since contact
status changes thermal conductivity. Refer to Contact-based Thermal Analysis in the
Users Guide for more information.
19. This card is represented as a group in HyperMesh.

590

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CONTPRM
Bulk Data Entry
CONTPRM Default Contact Properties
Description
Defines the default properties of all contacts and sets parameters that affect all contacts.
The default values set here can be overridden by values explicitly specified on PCONT,
PCONTX, and CONTACT cards.
Note: These defaults do not apply to properties of individual
gap elements that are specified on PGAP cards.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ONTPRM PARAM1

VALUE1

PARAM2

VALUE2

PARAM3

VALUE3

PARAM4

VALUE4

PARAM5

VALUE5

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C ONTPR
M

GPAD

0.5

STIFF

AUTO

MU1

0.3

Field

Contents

PARAMi

Name of parameter.

VALi

Value of parameter.

Altair Engineering

(8)

(9)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

591

Parameters for nonlinear quasi-static analysis


Name

Values

GPAD

Padding of master or slave objects to account for additional layers, such


as shell thickness, and so on. This value is subtracted from contact gap
opening as calculated from location of nodes. See comment 1.
Default = THICK (Real or NONE or THICK)

STIFF

Relative stiffness of gap. See comment 2.


Default = AUTO (AUTO, SOFT, HARD or Real > 0.0)

MU1

Coefficient of static friction ( s). See comments 3 and 4.


Default = 0.0 (Real > 0.0 or STICK or FREEZE)

MU2

Coefficient of kinetic friction ( k ).


Default = MU1 (0.0 < Real < MU1)

CONTGAP

Create a bulk data file that contains internally created node-to-surface


contact elements represented as CGAPG elements. The file name is:
filename_root.contgap.fem. See comment 6.
Default = NO (YES or NO)

CORIENT

Indicates whether the master orientation field MORIENT on the CONTACT


card applies to all surfaces or if it excludes solid elements.
Default = ONSHELL (ONSHELL or ONALL)
ONSHELL MORIENT applies only to contact masters that consist of shell
elements or patches of grids. Master surfaces defined as faces of solid
elements always push outwards, irrespective of initially open or prepenetrating contact.
ONALL MORIENT applies to all contact masters including, in particular,
solid elements.

SFPRPEN

Indicates whether initial pre-penetrations are recognized and resolved in


self-contact areas. (This only affects self-contact areas, wherein Master
and Slave belong to the same set or surface).
Default = YES (YES or NO)
YES Initial self-penetrations are recognized and resolved in self-contact
areas. There is some danger of finding false self-penetrations across
solids thinner than SRCHDIS (See comment 7).
NO There are no pre-penetrations to be resolved in self-contact areas,

592

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

except maybe minimal intrusions due to meshing, and so on. Any selfpenetrations larger than minimum element size will be ignored in those
areas (See comment 7).
FRICESL

Frictional elastic slip distance of sliding up to which the frictional


transverse force increases linearly with slip distance. Specified in physical
distance units (similar to U0 and GPAD). See comment 8.

Non-zero value or blank activates respective friction model based


on Elastic Slip Distance.

Zero value activates friction model based on fixed transverse


stiffness KT.

Default = AUTO (Real > 0.0 or AUTO)

Parameters for geometric nonlinear analysis (ANALYSIS = NLGEOM / IMPDYN /


EXPDYN in subcase)
Name

Values

STFAC

Interface stiffness scale factor.


Default = 1.0 in implicit analysis
Default = 0.1 in explicit analysis
(Real > 0)

FRIC

Coulomb friction.
Default = 0.0 (Real > 0)

GAP

Gap for impact activation (See comments 10 and 11).


(Real > 0)

IDEL

Flag for node and segment deletion.


Default = 0 (Integer = 0, , 2)
0 - No deletion.
1 - When all of the elements (shells, solids) associated to one segment are
deleted, the segment is removed from the master side of the interface.
Additionally, non-connected nodes are removed from the slave side of the
interface.
2 - When a shell or a solid element is deleted, the corresponding segment
is removed from the master side of the interface. Additionally, nonconnected nodes are removed from the slave side of the interface.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

593

INACTI

Flag for handling of initial penetrations (See comment 13).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - No action.
1 - Deactivation of stiffness on nodes.
2 - Deactivation of stiffness on elements.
3 - Change slave node coordinates to avoid small initial penetrations.
4 - Change master node coordinates to avoid small initial penetrations.
5 - Gap is variable with time but initial gap is slightly de-penetrated as
follows:
gap0 = gap - P0 0.05*(gap - P0)
Valid in explicit analysis: 0, 1, 2, 3 and 5.
Valid in implicit analysis: 0, 3 and 4.
Invalid entries are ignored.

CORIENT

Indicates whether the master orientation field MORIENT on the CONTACT


card applies to all surfaces, or if it excludes solid elements.
Default = ONSHELL (ONSHELL or ONALL)
ONSHELL MORIENT applies only to contact masters that consist of shell
elements or patches of grids. Master surfaces defined as faces of solid
elements always push outwards, irrespective of initially open or prepenetrating contact.
ONALL MORIENT applies to all contact masters including, in particular,
solid elements.

IFRIC

Friction formulation flag (See comment 15).


Default = COUL (Character = COUL, GEN, DARM, REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.
In implicit computation, only IFRIC = COUL is implemented.

IFILT

Friction filtering flag (See comment 14).


Default = NO (Character = NO, SIMP, PER, CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

594

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(0.0 < Real < 1.0)


IFORM

Type of friction penalty formulation (See comments 16 and 17).


Default = VISC (Character = VISC, STIFF)
VISC - Viscous (total) formulation.
STIFF - Stiffness (incremental) formulation.

C1, C2, C3,


C4, C5, C6

Friction law coefficients.

IGNORE

Flag to ignore slave nodes if no master segment is found for TIE contact
(See comment 18).

(Real > 0)

Default = 1 (Integer = 0, 1, 2)
0 - No deletion of slave nodes;
1 - Slave nodes with no master segment found are deleted from the
interface;
2 - Slave nodes with no master segment found are deleted from the
interface; if SRCHDIS is blank, then it would be newly calculated internally.
MTET10

Flag for second order CTETRA as contact master surface.


Default = 0 (Integer = 0, 1)
0 - TETRA 10 is degenerated on the surface (middle nodes are removed
from contact);
1 - Four triangular segments are used on each tetra face.

The following entries are relevant for explicit analysis only.


ISYM

Flag for symmetric contact.


Default = SYM (Character = SYM, UNSYM)
SYM Symmetric contact.
UNSYM Master-slave contact.
If SSID defines a grid set, the contact is always a master-slave contact.

IEDGE

Flag for edge generation from slave and master surfaces.


Default = NO (Character = NO, ALL, BORD, FEAT)
NO No edge generation.
ALL All segment edges are included.
BORD External border of slave and master surface is used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

595

FEAT External border as well as features defined by FANG are used.


FANG

Feature angle for edge generation in degrees (Only with IEDGE = FEAT).
Default = 91.0 (Real > 0)

IGAP

Flag for gap definition.


Default = CONST (Character = CONST, VAR)
CONST - Gap is constant and equal to GAP (See comments 11 and 12).
VAR - Gap is variable (in space, not in time) according to the
characteristics of the impacting surfaces and nodes (See comment 11).

ISTF

Flag for stiffness definition (See comment 9).


Default = 0 (Integer = 0, , 5)
0 - The stiffness is computed according to the master side characteristics.
1 - STIF1 is used as interface stiffness.
2, 3, 4 and 5 - The interface stiffness is computed from both master and
slave characteristics.

STIF1

Interface stiffness (Only with ISTF = 1).


Default = 0.0 (Real > 0)

STMIN

Minimum interface stiffness (Only with ISTF > 1).


(Real > 0)

STMAX

Maximum interface stiffness (Only with ISTF > 1).


Default = 1030 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact.


(Character = X, Y, Z, XY, XZ, YZ, XYZ)

VISS

Critical damping coefficient on interface stiffness.


Default = 0.05 (Real > 0)

VISF

Critical damping coefficient on interface friction.


Default = 1.0 (Real > 0)

BMULT

Sorting factor.
Default = 0.20 (Real > 0)

596

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments for quasi-static analysis


1.

The initial gap opening is calculated automatically based on the relative location of slave
and master nodes (in the original, undeformed mesh). To account for additional material
layers covering master or slave objects (such as half of shell thickness), the GPAD entry
can be used. GPAD option THICK automatically accounts for shell thickness on both sides
of the contact interface (this also includes the effects of shell element offset ZOFFS or
composite offset Z0).

2.

Option STIFF=AUTO determines the value of normal stiffness for each contact element
using the stiffness of surrounding elements. Additional options SOFT and HARD create
respectively softer or harder penalties. SOFT can be used in cases of convergence
difficulties and HARD can be used if undesirable penetration is detected in the solution.

3.

Prescribing MU1=STICK is interpreted in OptiStruct as an enforced stick condition - such


contact interfaces will not enter the sliding phase. Of course, the enforced stick only
applies to contacts that are closed.

4.

Prescribing MU1=FREEZE enforces zero relative displacements on the contact surface


the contact gap opening remains fixed at the original value and the sliding distance is
zero. The FREEZE condition applies to all slave nodes, no matter whether their initial gap
is open or closed.

5.

This card is represented as a control card in HyperMesh.

6.

The file filename_root.contgap.fem, produced using the CONTGAP parameter, can be


imported into HyperMesh in order to visualize internally created node-to-surface contact
elements (now converted to GAPG entities). Note that during optimization, this file shows
node-to-surface contact elements for the latest optimization iteration. In order to
correctly visualize this configuration in HyperMesh for shape optimization problems, the
FEA mesh shape needs to be updated by applying "Shape change" results.
Furthermore, if GAPPRM,HMGAPST,YES is activated together with
CONTPRM,CONTGAP,YES, then the gap status command file,
filename_root.HM.gapstat.cmf, will also include the open/closed status of these
additional GAPGs that represent node-to-surface contact elements. For correct
visualization of their status in HyperMesh, file filename_root.contgap.fem needs to be
imported before running the gap status command file.

7.

The CONTACT capability in NLSTAT solution is designed to correctly resolve initial prepenetration, such as happens in press fit, and so on. This usually works reliably with
correct identification of Master and Slave surfaces. However, in some cases users create
contact surfaces by property for convenience, which results in contact surfaces
enveloping the entire solid bodies. Also, sometimes the Slave and Master receive the
same ID, which is known as self-contact (and is not a recommended practice, in spite of
the convenience factor). In such cases, it is possible to encounter false selfpenetrations, as illustrated below:

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

597

In the case above, the Slave node will be identified as if pre-penetrating the Master face,
while in reality it is on the other side of the same solid body. The result from nonlinear
CONTACT solution will be such that this portion of the body will be squeezed to have
practically zero thickness, with very high stresses obviously resulting.
Apart from correctly identifying potential Slave and Master sets, a possible remedy to
avoid such situations is to make sure that SRCHDIS is smaller than minimum thickness of
the solid bodies which are enveloped by self-contacting surfaces.
An alternative, viable when there are no actual pre-penetrations in the problem, is to
choose SFPRPEN = NO, which will ignore initial pre-penetrations on self-contacting
surfaces (some minor pre-penetrations due to variations of nodal positions will still be
correctly resolved up to the minimum element size on the respective contact surfaces).
Note that SFPRPEN affects only surfaces that actually have self-penetration, as in a case
where the Slave Node and Master Face belong to the same contact set or surface. On
properly defined, disjoint Slave and Master surfaces, the initial pre-penetrations will be
resolved irrespective of this parameter.
8.

Effective in Release 12.0, two models of friction are available in nonlinear analysis:
(a) Model based on fixed slope KT (previously existing),
(b) Model based on Elastic Slip Distance FRICESL (introduced in v12.0 and current default).
This latter model typically shows better performance in solution of frictional problems
thanks to more stable handling of transitions from stick to slip. Key differences between
the two available models are illustrated in the figure below (F 1 and F 2 represent two
different values of normal force F x ):

598

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C omparison of the two available friction models for contact elements.

Model (a), based on fixed stiffness KT, is relatively simple, yet has certain drawback in
modeling nonlinear friction. Namely, in Coulomb friction the frictional resistance depends
upon normal force. Using fixed KT will predict different range of stick/slip boundary for
different normal forces, and thus may qualify the same configuration as stick or slip,
depending on normal force.
Model (b), based on Elastic Slip Distance, provides unique identification of stick or slip
and generally performs better in solution of problems with friction. This model does
require prescribing elastic slip distance FRICESL for contact interfaces this value is
determined automatically as 0.5% of typical element size on all Master contact
surfaces.
The model (b), which is currently the default, is recommended for solution of nonlinear
problems with friction. For backwards compatibility, the model based on fixed KT can be
activated by prescribing FRICESL=0 on PCONT or CONTPRM card.
Comments for geometric nonlinear analysis (ANALYSIS = NLGEOM / IMPDYN / EXPDYN
in subcase)
9.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells as well as when the master segment is shared by a shell and
solid.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V-3 for
solids, Ks = 0.5 * STFAC * E * t for shells.
In these equations, B is the Bulk Modulus, S is the segment area, E is the modulus of
elasticity, t is shell thickness, and V is the volume of a solid. There is no limitation to the
value of stiffness factor (but a value larger than 1.0 can reduce the initial time step).
ISTF = 0, the interface stiffness K = Km
ISTF > 1, the interface stiffness is then K = max (STMIN, min (STMAX, K1)) with
ISTF = 2, K1 = 0.5 * (Km + Ks)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

599

ISTF = 3, K1 = max (Km, Ks)


ISTF = 4, K1 = min (Km, Ks)
ISTF = 5, K1 = Km * Ks / (Km + Ks)
10. In an implicit analysis, the contact stiffness plays a very important role in convergence.
ISTF = 4 (which takes the minimum of master and slave stiffnesss for contact) is
recommended. This is because the penalty contact force will be balanced with the
internal force of the deformable impacted part. That means the stiffness near the
effective stiffness one will converge easier than a higher one.
For small initial gaps in implicit analysis, the convergence will be more stable if a GAP is
defined that is larger than the initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example:
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.
11. The default for the constant gap (IGAP = CONST) is the minimum of
t, average thickness of the master shell elements;
l/10, l average side length of the master solid elements;
lmin/2, lmin smallest side length of all master segments (shell or solid).
12. The variable gap (IGAP = VAR) is computed as gs + gm
with:
gm - master element gap with
gm = t/2, t: thickness of the master element for shell elements.
gm = 0 for solid elements.
gs - slave node gap:
gs = 0 if the slave node is not connected to any element or is only connected to solid or
spring elements.
gs = t/2, t - largest thickness of the shell elements connected to the slave node.
and beam elements, with S being the cross-section of the element.
If the slave node is connected to multiple shells and/or beams or trusses, the largest
computed slave gap is used.
The variable gap is always at least equal to GAPMIN.
13. INACTI = 3, 4 are only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations if several surface layers are defined in the
interfaces.

600

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

it may create initial energy if the node belongs to a spring element.


INACTI = 5 works as follows:

14.
the tangential friction forces are smoothed using a filter:
F T = * F'T + (1 - ) * F'T -1
where,
F T - Tangential force
F'T - Tangential force at time t
F'T - 1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2 dt/FFAC, where dt/T = FFAC, T is the filtering period
IFILT = CUTF = 2 * FFAC * dt, where FFAC is the cutting frequency
15. IFRIC defines the friction model.
IFRIC = COUL Coulomb friction with F T <

* F N with

= FRIC

For IFRIC is not COUL, the friction coefficient is set by a function ( = (p, V)), where p is
the pressure of the normal force on the master segment and V is the tangential velocity
of the slave node.
The following formulations are available:
IFRIC = GEN - Generalized viscous friction law
= Fric + C1 * p + C2 * V + C3 * p * V + C4 * p2 + C5 * V2
IFRIC = DARM - Darmstad law
= C1

e(C 2 V )

Altair Engineering

p2 + C3

e(C 4 V )

p + C5

e(C 6 V )

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

601

IFRIC = REN - Renard law

The first critical velocity Vcr1


than the second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2 must be lower
than the maximum friction C3 (C1 < C3 ) and C2 < C3 ).
The minimum friction coefficient C4 , must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2 ).
16. IFROM selects two types of contact friction penalty formulation.
The viscous (total) formulation (IFORM = VISC) computes an adhesive force as
F adh = VISF * Sqrt(2Km) * VTF T = min (F N, F adh)
The stiffness (incremental) formulation (IFORM = STIFF) computes an adhesive force as
F adh = F Told + F T
F T = K * VT * dt

602

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

F Tnew = min (F N, F adh )


17. For nonlinear implicit contact with friction, the stiffness formulation (IFORM = STIFF) is
recommended.
18. If IGNORE = 1 or 2, the slave nodes without a master segment found during the searching
are deleted from the interface.
If IGNORE = 1 and SRCHDIS is blank, then the default value of the distance for searching
closest master segment is the average size of the master segments.
If IGNORE = 2 and SRCHDIS is blank, then the distance for searching closest master
segment is computed as follows for each slave node:
d1 = 0.6 * (T s + T m)
d2 = 0.05 * T md
SRCHDIS = max(d1, d2 )
where,
T s is the thickness of the element connected to the slave node, for solids T s = 0.0
T m is the thickness of master segment, for solids T m = Element volume / Segment area
T md is the master segment diagonal
19. This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

603

CONTX11
Bulk Data Entry
CONTX11 Edge to Edge or Line to Line Contact Interface Definition for Geometric Nonlinear
Analysis
Description
Defines a edge to edge or line to line contact interface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

C ONTX11

C TID

PID

SLID

MLID

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ONTX11

10

(6)

Field

Contents

CTID

Contact interface identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
PID

Property identification number of a PCONT entry. See comment 2.


(Integer > 0)

SLID

Identification number of slave LINE entity. See comments 3 and 4.


(Integer > 0)

MLID

Identification number of master LINE entity. See comments 3 and 4.


(Integer > 0)

604

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

CONTX11 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

2.

The property of CONTX11(PID) only can be defined by PCONT and its extended card
PCNTX11.

3.

CONTX11 defines contact interface type 11, it describes the edge to edge or line to line
interface. This interface simulates impact between lines, a line can be a beam or truss
element or a shell edge or spring elements. The interface properties are:
impacts occur between a master and a slave line;
a slave line can impact on one or more master lines;
a line can belong to the master and the slave side. This allows self impact;
this interface can be used in addition to the interface type 7 PCNTX7 to solve the
edge to edge limitation of interface type 7.

4.

The slave line entity SLID and master line set entity MLID must be defined via LINE:
a set of edges or lines of 1-D, 2-D or 3-D elements;
a set of elements (bars, beams, springs or shells), defined using SET(ELEM,...)
command;

5.

This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

605

CONV
Bulk Data Entry
CONV Free Convection
Description
Defines a free convection boundary condition for heat transfer analysis through connection to
a surface element (CHBDYE card).
Format
(1)

(2)

(3)

C ONV

EID

PC ONID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TA

Field

Contents

EID

CHBDYE surface element identification number.


No default (Integer > 0)

PCONID

Convection property identification number of a PCONV card.


No default (Integer > 0)

TA

Ambient points used to specify ambient temperature.


No default (Integer > 0)

Comments
1.

The basic exchange relationship is expressed as:

q = H * (T - TAMB)
Where, H is the free convection heat transfer coefficient specified on a MAT4 card
referred by a PCONV card, T is the grid temperature, and TAMB is the ambient
temperature.
2.

CONV is used with a CHBDYE card having the same EID.

3.

In linear steady-state heat transfer analysis, ambient temperature is specified by SPC of


the TA point.

4.

This card is represented as a slave element in HyperMesh.

606

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CORD1C
Bulk Data Entry
CORD1C Cylindrical Coordinate System Definition, Form 1
Description
This entry defines a cylindrical coordinate system using three grid points. The first point is
the origin, the second lies on the Z-axis, and the third lies in the X-Z plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD1C

C ID

G1

G2

G3

C ID

G1

G2

G3

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ORD1C

16

32

19

(6)

(7)

Field

Contents

CID

Unique coordinate system identification number.

(8)

(9)

(10)

(Integer > 0)
G1, G2, G3

Grid point identification numbers of points used to uniquely define the


cylindrical coordinate system (see Figure 1).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

607

Figure 1: Defining a C ylindrical C oordinate System (C ID) using grid points G1, G2 and G3.

Comments
1.

Coordinate system identification numbers (CID) on all CORD1R, CORD1C, CORD1S,


CORD2R, CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

2.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

3.

The three points G1, G2, G3 must be non-collinear. Non-collinearity is checked by the
geometry processor.

4.

The location of a grid point (P in Figure 1) in this cylindrical coordinate system is given by
(R, , and Z) where, is measured in degrees.

5.

The displacement coordinate directions at P are dependent on the location of P (ur, u,


and uz) as shown in Figure 1. The displacements in all three of these directions at the
grid point are specified in units of length.
In OptiStruct, the cylindrical and spherical coordinate systems are internally resolved to
entity-position-dependent (example: GRID) rectangular systems. Therefore, when a grid
point is located in a cylindrical system, OptiStruct constructs a rectangular system at
that location for the grid point. The R-direction corresponds to the X-axis, the Z-axis is
the same, and the axis is tangential to the X (or R) axis. Now the various degrees of
freedom can be resolved (vis--vis constraints) similar to a general rectangular system.
Care must be taken to observe that the internally generated rectangular systems are
dependent on the grid point location in the cylindrical system. So they may be different
for different grid point locations within the same cylindrical system.

608

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

Points on the Z-axis should not have their displacement directions defined in this
coordinate system due to ambiguity. In this case, the defining rectangular system is used.

7.

A maximum of two coordinate systems may be defined on a single entry.

8.

This card is represented as a system in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

609

CORD1R
Bulk Data Entry
CORD1R Rectangular Coordinate System Definition, Form 1
Description
This entry defines a rectangular coordinate system using three grid points. The first point is
the origin, the second lies on the Z-axis, and the third lies on the X-Z plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD1R

C ID

G1

G2

G3

C ID

G1

G2

G3

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ORD1R

16

32

19

(6)

(7)

Field

Contents

CID

Unique coordinate system identification number.

(8)

(9)

(10)

(Integer > 0)
G1, G2, G3

610

Grid point identification numbers of points used to uniquely define the


rectangular coordinate system (see Figure 1).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1: Defining a Rectangular C oordinate System (C ID) using grid points G1, G2 and G3.

Comments
1.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

2.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

3.

The three points G1, G2, and G3 must be non-collinear. Non-collinearity is checked by
the geometry processor.

4.

The location of a grid point (P in Figure 1) in this rectangular coordinate system is given
by (X, Y, and Z).

5.

The displacement coordinate directions at P are (Ux , Uv , and Uz) as shown in Figure 1.

6.

A maximum of two coordinate systems may be defined on a single entry.

7.

In geometric nonlinear analysis, CORD1R is a moving coordinate system. It moves with


GRID points defining the system.

8.

This card is represented as a system in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

611

CORD1S
Bulk Data Entry
CORD1S Spherical Coordinate System Definition, Form 1
Description
This entry defines a spherical coordinate system using three grid points. The first point is the
origin, the second lies on the polar (Z) axis, and the third lies in the X-Z plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD1S

C ID

G1

G2

G3

C ID

G1

G2

G3

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ORD1S

16

32

19

(6)

(7)

Field

Contents

CID

Unique coordinate system identification number.

(8)

(9)

(10)

(Integer > 0)
G1, G2, G3

612

Grid point identification number.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1: Defining a Spherical C oordinate System (C ID) using grid points G1, G2 and G3.

Comments
1.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

2.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

3.

The three points G1, G2, and G3 must be non-collinear. Non-collinearity is checked by
the geometry processor.

4.

The location of a grid point (P in Figure 1) in this spherical coordinate system is given by
(R, , and ). Where, and are measured in degrees.

5.

The displacement coordinate directions at P are dependent on the location of P (ur, u,


and u ) as shown in Figure 1. The displacements in all three of these directions at the
grid point are specified in units of length.

6.

Points on the polar axis may not have their displacement directions defined in this
coordinate system due to ambiguity. In this case, the defining rectangular system is
used.

7.

A maximum of two coordinate systems may be defined on a single entry.

8.

This card is represented as a system in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

613

CORD2C
Bulk Data Entry
CORD2C Cylindrical Coordinate System Definition, Form 2
Description
This entry defines a cylindrical coordinate system using three grid points specified with
respect to a reference coordinate system. The coordinates of the three non-collinear grid
points are used to uniquely define the coordinate system. The first point defines the origin.
The second point defines the direction of the Z-axis. The third lies in the X-Z plane (see
Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD2C

C ID

RID

A1

A2

A3

B1

B2

B3

C1

C2

C3

(10)

Example

(1)

(2)

C ORD2C

5.2

(3)

1.0

(4)

(5)

(6)

(7)

(8)

(9)

-2.9

1.0

0.0

3.6

0.0

1.0

(10)

-2.9

Field

Contents

CID

Unique coordinate system identification number.


(Integer > 0)

RID

Identification number of a reference coordinate system that is defined


independently from this coordinate system (see comment 7).
Default = 0 (Integer > 0)

614

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

A1,A2,A3
B1,B2,B3
C1,C2,C3

Coordinates of three points in the reference coordinate system (RID). If


RID is blank or 0, then the reference coordinate system is the default
basic coordinate system.
(Real)

Figure 1: Defining a C ylindrical C oordinate System (C ID) using points A, B and C with reference to another
coordinate system (RID).

Comments
1.

The three points (A1, A2, A3), (B1, B2, B3), (C1, C2, C3) must be unique and noncollinear. Non-collinearity is checked by the geometry processor.

2.

Coordinate system identification numbers (CID) on all CORD1R, CORD1C, CORD1S,


CORD2R, CORD2C, CORD2S, CORD3R, and CORD4R entries must be unique.

3.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

4.

The location of a grid point (P in Figure 1) in this cylindrical coordinate system is given by
(R, , and Z). Where, is measured in degrees.

5.

The displacement coordinate directions at P are dependent on the location of P (Ur, U,


and Uz) as shown in Figure 1. The displacements in these three directions at the grid
point are specified in units of length.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

615

In OptiStruct, the cylindrical and spherical coordinate systems are internally resolved to
entity-position-dependent (example: GRID) rectangular systems. Therefore, when a grid
point is located in a cylindrical system, OptiStruct constructs a rectangular system at
that location for the grid point. The R-direction corresponds to the X-axis, the Z-axis is
the same, and the axis is tangential to the X (or R) axis. Now the various degrees of
freedom can be resolved (vis--vis constraints) similar to a general rectangular system.
Care must be taken to observe that the internally generated rectangular systems are
dependent on the grid point location in the cylindrical system. So they may be different
for different grid point locations within the same cylindrical system.
6.

Points on the Z-axis should not have their displacement directions defined in this
coordinate system due to ambiguity.

7.

The reference coordinate system (RID) should be independently defined or left blank. If
blank (or 0), the reference coordinate system is the default basic coordinate system. In
such cases, A, B and C are defined with respect to the basic coordinate system.

8.

This card is represented as a system in HyperMesh.

616

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CORD2R
Bulk Data Entry
CORD2R Rectangular Coordinate System Definition, Form 2
Description
The entry defines a rectangular coordinate system by using three grid points. The coordinates
of the three non-collinear grid points are used to uniquely define the coordinate system. The
first point defines the origin. The second defines the direction of the Z-axis. The third point
defines a vector, which, with the Z-axis, defines the X-Z plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD2R

C ID

RID

A1

A2

A3

B1

B2

B3

C1

C2

C3

(10)

Example

(1)

(2)

C ORD2R

5.2

(3)

1.0

(4)

(5)

(6)

(7)

(8)

(9)

-2.9

1.0

0.0

3.6

0.0

1.0

(10)

-2.9

Field

Contents

CID

Unique coordinate system identification number.


(Integer > 0)

RID

Identification number of a coordinate system that is defined independently


from this coordinate system (see comment 6).
Default = 0 (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

617

Field

Contents

A1,A2,A3
B1,B2,B3
C1,C2,C3

Coordinates of three points in the reference coordinate system (RID). If


RID is blank or 0, then the reference coordinate system is the default
basic coordinate system.
(Real)

Figure 1: Defining a Rectangular C oordinate System (C ID) using points A, B and C with reference to another
coordinate system (RID).

Comments
1.

The three points (A1, A2, and A3), (B1, B2, and B3), and (C1, C2, and C3) must be
unique and non-collinear. Non-collinearity is checked by the geometry processor.

2.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

3.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

4.

The location of a grid point (P in Figure 1) in this rectangular coordinate system is given
by (X, Y, and Z).

5.

The displacement coordinate directions at P are (Ux , Uv , and Uz) as shown in Figure 1.

618

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

The reference coordinate system (RID) should be independently defined or left blank. If
blank (or 0), the reference coordinate system is the default basic coordinate system. In
such cases, A, B and C are defined with respect to the basic coordinate system.

7.

This card is represented as a system in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

619

CORD2S
Bulk Data Entry
CORD2S Spherical Coordinate System Definition, Form 2
Description
This entry defines a spherical coordinate system three grid points. The coordinates of the
three non-collinear grid points are used to uniquely define the coordinate system. The first
point defines the origin. The second point defines the direction of the Z-axis. The third lies in
the X-Z plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD2S

C ID

RID

A1

A2

A3

B1

B2

B3

C1

C2

C3

(10)

Example

(1)

(2)

C ORD2S

5.2

(3)

1.0

(4)

(5)

(6)

(7)

(8)

(9)

-2.9

1.0

0.0

3.6

0.0

1.0

(10)

-2.9

Field

Contents

CID

Unique coordinate system identification number.


(Integer > 0)

RID

Identification number of a coordinate system that is defined


independently from this coordinate system (see comment 7).
Default = 0 (Integer > 0)

A1,A2,A3

620

Coordinates of three points in the reference coordinate system (RID). If

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

B1,B2,B3
C1,C2,C3

RID is blank or 0, then the reference coordinate system is the default


basic coordinate system.
(Real)

Figure 1: Defining a Spherical C oordinate System (C ID) using grid points A, B and C .

Comments
1.

The three points (A1, A2, and A3), (B1, B2, and B3), and (C1, C2, and C3) must be
unique and non-collinear. Non-collinearity is checked by the geometry processor.

2.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

3.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

4.

The location of a grid point (P in Figure 1) in this spherical coordinate system is given by
(R, , and ). Where, and are measured in degrees.

5.

The displacement coordinate directions at P are (ur, u, and u ) as shown in Figure 1.


The displacements in all three of these directions at the grid point are specified in units of
length.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

621

6.

Points on the polar axis may not have their displacement directions defined in this
coordinate system due to ambiguity.

7.

The reference coordinate system (RID) should be independently defined or left blank. If
blank (or 0), the reference coordinate system is the default basic coordinate system. In
such cases, A, B and C are defined with respect to the basic coordinate system.

8.

This card is represented as a system in HyperMesh.

622

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CORD3R
Bulk Data Entry
CORD3R Rectangular Coordinate System Definition, Form 3
Description
The entry defines a rectangular coordinate system using three grid points. The first point is
the origin, the second lies on the X-axis, and the third lies on the X-Y plane (see Figure 1).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ORD3R

C ID

G1

G2

G3

C ID

G1

G2

G3

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ORD3R

16

32

19

(6)

(7)

Field

Contents

CID

Unique coordinate system identification number.

(8)

(9)

(10)

(Integer > 0)
G1, G2, G3

Grid point identification numbers of points used to uniquely define the


rectangular coordinate system (see Figure 1).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

623

Figure 1: Defining a Rectangular C oordinate System (C ID) using grid points G1, G2 and G3.

Comments
1.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

2.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL. Refer to Guidelines for Bulk Data
Entries.

3.

The three points G1, G2, and G3 must be non-collinear. Non-collinearity is checked by
the geometry processor.

4.

The location of a grid point (P in Figure 1) in this rectangular coordinate system is given
by (X, Y, and Z).

5.

The displacement coordinate directions at P are (Ux , Uv , and Uz) as shown in Figure 1.

6.

A maximum of two coordinate systems may be defined on a single entry.

7.

In geometric nonlinear analysis, CORD3R is a moving coordinate system. It moves with


grid points defining the system.

8.

The implementation of CORD3R in OptiStruct is different from that of NASTRAN. A CORD3R


coordinate system in OptiStruct can be defined by specifying grid point identification
numbers for the Origin, X-axis and the XY plane, whereas CORD3R in NASTRAN is specified
with reference to the Origin, Z-axis and the XZ plane.

9.

This card is represented as a system in HyperMesh.

624

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CORD4R
Bulk Data Entry
CORD4R Rectangular Coordinate System Definition, Form 4
Description
This entry defines a rectangular coordinate system using three grid points specified with
respect to the basic coordinate system. The coordinates of the three non-collinear grid points
are used to uniquely define the coordinate system. The first point is the origin, the second lies
on the X-axis, and the third lies on the X-Y plane (see Figure 1).
Format
(1)

(2)

(3)

C ORD4R

C ID

C1

C2

(4)

(5)

(6)

(7)

(8)

(9)

A1

A2

A3

B1

B2

B3

(10)

C3

Example

(1)

(2)

C ORD4R

5.2

(3)

1.0

(4)

(5)

(6)

(7)

(8)

(9)

-2.9

1.0

0.0

3.6

0.0

1.0

(10)

-2.9

Field

Contents

CID

Unique coordinate system identification number.


(Integer > 0)

A1,A2,A3
B1,B2,B3
C1,C2,C3

Coordinates of three points in the basic coordinate system.


(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

625

Figure 1: C ORD4R definition.

Comments
1.

Coordinate system identification numbers on all CORD1R, CORD1C, CORD1S, CORD2R,


CORD2C, CORD2S, CORD3R, and CORD4R entries must all be unique.

2.

A duplicate identification number is allowed if the CID and GID are identical and the
coordinates are within the value set by PARAM, DUPTOL (see Guidelines for Bulk Data
Entries for further information).

3.

The three points (A1, A2, and A3), (B1, B2, and B3), and (C1, C2, and C3) must be
unique and non-collinear. Non-collinearity is checked by the geometry processor.

4.

The location of a grid point (P in Figure 1) in this rectangular coordinate system is given
by (X, Y, and Z).

5.

The displacement coordinate directions at P are (Ux , Uv , and Uz) as shown in Figure 1.

6.

A maximum of two coordinate systems may be defined on a single entry.

7.

This card is represented as a system in HyperMesh.

626

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

COUPLER
Bulk Data Entry
COUPLER Coupler Definition for Multi-body Solution Sequence
Description
Defines a coupler connecting two or three joints.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C OUPLER

C OID

JID1

TYPE1

RATIO1

JID2

TYPE2

RATIO2

JID3

TYPE3

RATIO3

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C OUPLER

2.0

1.0

Field

Contents

COID

Unique coupler identification number.

(9)

(10)

(Integer > 0)
JIDi

Joint identification numbers.


No default (Integer > 0)

TYPEi

Type.
No default (TRA or ROT) See comment 3.

RATIOi

Coefficients of the coupler constraint equation.


(Real; Default = 1.0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

627

Comments
1.

COUPLERs are only valid in a multi-body solution sequence.

2.

At least JID1 and JID2 need to be defined.

3.

The type is optional if the Joint is revolute or translation. But if the joint is cylindrical,
the type should be set to TRA to denote that the translational motion is coupled or ROT
to specify that the rotational motion is coupled.

628

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CPENTA
Bulk Data Entry
CPENTA Five-sided Solid Element with six or fifteen grid points
Description
Defines the connections of the CPENTA element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C PENTA

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

G13

G14

G15

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C PENTA

112

15

14

103

115

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSOLID property entry.


Default = EID (Integer > 0)

G#

Identification numbers of connected grid points.


Default = blank (Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

629

Comments
1.

Element ID numbers must be unique with respect to all other element ID numbers.

2.

The topology of the diagram must be preserved, that is, G1, G2, and G3 define a
triangular face, G1-G4, G2-G5, and G3-G6 each form one edge.
The edge points, G7-G15, are optional. If any of the edge points are present, they all
must be used. The second and third continuation is not needed for the six node version
of this element.
It is recommended that the edge points be placed near the middle of the edge.

C PENTA definition

3.

If the user-prescribed node numbering on the bottom and top faces is reversed as
compared to the sequence shown above, then the nodes are renumbered to produce
right-handed orientation of numbering. This is accomplished by swapping nodes G1 with
G3 and G4 with G6. For 15-noded CPENTA, appropriate changes to mid-side node
numbering are also performed. In such cases, the element coordinate system will be built
on the renumbered node sequence.

4.

Stresses are output in the material coordinate system. The material coordinate system is
defined on the referenced PSOLID entry. It may be defined as the basic coordinate
system (CORDM = 0), a defined system (CORDM = Integer > 0), or the element coordinate
system (CORDM = -1).

5.

The element coordinate system for the CPENTA element is defined as follows:

630

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C PENTA element coordinate system

The origin of the element coordinate system is located at the mid-point of a straight line
from G1 to G4.
The element z-axis corresponds to the average of the vector connecting the centroid of
triangular face G1-G2-G3 to the centroid of the triangular face G4-G5-G6 and the normal
vector of the mid-plane (the plane on which the mid-points of the straight lines G1-G4,
G2-G5, and G3-G6 lie). The positive sense of the z-axis is toward the triangular face G4G5-G6.
The element y-axis is perpendicular to the element z-axis and lies on the plane created by
the element z-axis and the line connecting the origin and the mid-point of a straight line
from G3 to G6. The positive sense of the y-axis is toward the straight line from G3 to G6.
The element x-axis is the cross product of the element y-axis and the element z-axis.
6.

This card is represented as a penta6 or penta15 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

631

CPYRA
Bulk Data Entry
CPYRA Five-sided Solid Element with five or thirteen grid points
Description
Defines the connections of the PYRA solid element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C PYRA

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

G11

G12

G13

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

C PYRA

71

Field

Contents

EID

Unique element identification number.

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSOLID property entry.


Default = EID (Integer > 0)

G#

Grid point identification numbers of connection points.


Default = blank (Integer > 0 or blank)

632

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Grid points G1,,G4 must be given in consecutive order about the quadrilateral face.
The edge points, G6 through G13, are optional. If any of the edge points are present,
they all must be used. The continuation must not be present for the 5-noded version of
this element.
It is recommended that the edge points be placed near the middle of the edge.

C PYRA definition

3.

Stresses are output in the material coordinate system. The material coordinate system is
defined on the referenced PSOLID entry. It may be defined as the basic coordinate
system (CORDM = 0), a defined system (CORDM = Integer > 0), or the element coordinate
system (CORDM = -1).

4.

The element coordinate system for the CPYRA element is defined as follows:
Three intermediate vectors R, S, and T are chosen by the following rules:
R

Joins the midpoints of the edges from G1 to G4 and G2 to G3.

Joins the midpoints of the edges from G1 to G2 and G3 to G4.

Joins the intersection of R and S to G5.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

633

C PYRA element coordinate system

The origin of the element coordinate system is located at the intersection of the vectors
R and S.
The element z-axis corresponds to the T vector.
The element y-axis is the cross product of the T and R vectors.
The element x-axis is the cross product of the element y-axis and the element z-axis.
5.

634

This card is represented as a pyra5 or pyra13 element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
Bulk Data Entry
CQUAD4 Quadrilateral Element Connection
Description
Defines a quadrilateral plate element (QUAD4) of the structural model. This element uses a 6
degree-of-freedom per node formulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C QUAD4

EID

PID

G1

G2

G3

G4

Theta
or
MC ID

ZOFFS

T1

T2

T3

T4

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C QUAD4

111

203

31

74

75

32

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSHELL, PCOMP, PCOMPP or PHFSHL property


entry.
Default = EID (Integer > 0)

G1,G2,G3,G4

Grid point identification numbers of connection points.


No default (Integers > 0, all unique)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

635

Field

Contents

Theta

Material orientation angle in degrees.


Default = 0.0 (Real)

MCID

Material coordinate system identification number. The x-axis of this


coordinate system is projected onto the element to define the x-axis of
the material coordinate system. If MCID = 0, it specifies the basic
coordinate system. MCID must be an integer > 0. If blank, Theta =
0.0 is used, unless the material referenced by the element is isotropic
(MAT1) then MCID = 0 is used. See comments 4, 5, and 6.
Default is Theta = 0.0 (Integer > 0)

ZOFFS

Offset from the plane defined by element grid points to the shell
reference plane. See comment 10. Overrides the ZOFFS specified on
the PSHELL entry.
Default = 0.0 (Real or blank)

Ti

Thickness of the element at the grid points. Overrides the thickness


specified on the PSHELL entry. If Ti is specified, the average of all four
thicknesses is used as the element thickness.
For defaults: See comments 7 and 9.
(Real > 0.0 or blank)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Grid points G1 through G4 must be ordered consecutively around the perimeter of the
element.

3.

All of the interior angles must be less than 180 degrees.

4.

The elemental coordinate system is a bisection definition as depicted in the following


figure:

636

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Elemental coordinate system

5.

For H3D and OUTPUT2 output formats, stresses and strains are always output in the
elemental system.

6.

For HM, PUNCH and OPTI output formats, stresses and strains are output by default in
the material coordinate system. PARAM, OMID can be set to NO to output results in the
elemental system. For elements with blank Theta/MCID, THETA = 0.0 is assumed, and
the material coordinate system is aligned with side G1-G2 of the shell element. For
elements with prescribed THETA, the material x-axis is rotated from side G1-G2 by angle
THETA. For elements with prescribed MCID, the material system is constructed by
projecting the prescribed MCID onto the plane of the element.

Orientation when Theta (real value) is entered in 8th field

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

637

Orientation when MC ID (integer value) is entered in 8th field

7.

If any of the Ti fields are blank, the thickness specified on the PSHELL data will be used
for that nodes thickness. If 0.0 is specified for Ti, then the thickness at that node is
zero.

8.

If the property referenced by PID is selected as a region for free-size or size optimization,
then any Ti values defined here are ignored. If you input Ti for elements in the design
space for Topology or Free-Size optimization, the run will error out.

9.

If Ti is present, the PID cannot reference PCOMP or PCOMPP data.

10. The shell reference plane can be offset from the plane defined by element nodes by
means of ZOFFS. In this case all other information, such as material matrices or fiber
locations for the calculation of stresses, is given relative to the offset reference plane.
Similarly, shell results, such as shell element forces, are output on the offset reference
plane.
ZOFFS can be input in two different formats:
1. Real:
A positive or a negative value of ZOFFS is specified in this format. A positive value of
ZOFFS implies that the reference plane of each shell element is offset a distance of
ZOFFS along the positive z-axis of its element coordinate system.
2. Surface:
This format allows you to select either Top or Bottom option to specify the offset
value.
Top:
The top surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate

638

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

system, as defined in the Real section). See Figure 1.

Figure 1: Top option in ZOFFS

Bottom:
The bottom surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 2.

Figure 2: Bottom option in ZOFFS

Note that when ZOFFS is used, both MID1 and MID2 must be specified on the PSHELL
entry referenced by this element (otherwise, singular matrices would result).
Offset is applied to all element matrices (stiffness, mass, and geometric stiffness), and to
respective element loads (such as gravity). Hence, ZOFFS can be used in all types of
analysis and optimization. Note, however, that for first order shell elements (CQUAD4 and
CTRIA3), the offset operation does not correct for secondary effects, such as change of
shell area when offset is applied on curved surfaces. Hence, the value of ZOFFS should
be kept within a reasonable percentage (10% - 15%) of the local radius of curvature.
Automatic offset control is available in composite free-size and sizing optimization where
the specified offset values are automatically updated based on thickness changes.
Moreover, while offset is correctly applied in geometric stiffness matrix and hence can be
used in linear buckling analysis, caution is advised in interpreting the results. Without
offset, a typical simple structure will bifurcate and loose stability instantly at the critical

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

639

load. With offset, though, the loss of stability is gradual and asymptotically reaches a
limit load, as shown below in figure (b):

Hence, the structure with offset can reach excessive deformation before the limit load is
reached. Note that the above illustrations apply to linear buckling in a fully nonlinear
limit load simulation, additional instability points may be present on the load path.
11. PHFSHL properties are only valid with an @HYPERFORM statement in the first line of the
input file.
12. This card is represented as a quad4 element in HyperMesh.

640

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD8
Bulk Data Entry
CQUAD8 Curved Quadrilateral Shell Element Connection
Description
Defines a curved quadrilateral shell element with eight grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C QUAD8

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

T1

T2

T3

T4

Theta
or
MC ID

ZOFFS

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C QUAD8

111

203

20

21

50

51

26

94

95

23

0.125

0.025

0.030

.025

30.

.03

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSHELL, PCOMP or PCOMPP property entry.


Default = EID (Integer > 0)

G1,G2,G3,G4

Grid point identification numbers of connected corner points. Required


data for all four grid points.
No default (Integers > 0, all unique)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

641

Field

Contents

G5,G6,G7,G8

Grid point identification numbers of connected edge points. Cannot be


omitted.
No default (Integer > 0 or blank)

Ti

Thickness of the element at the corner grid points G1 through G4. The
thickness of the element with Ti specified will be constant and equal to
an average of T1, T2, T3 and T4.
For defaults: see comment 5.
(Real > 0.0 or blank)

THETA

Material orientation angle in degrees. See comment 4.


Default = 0,0 (Real)

MCID

Material coordinate system identification number. The x-axis of this


coordinate system is projected onto the element to define the x-axis
of the material coordinate system. If MCID = 0, it specifies the basic
coordinate system. If blank, Theta = 0.0 is used, (See comments 3
and 4).
Default is THETA = 0.0 (Integer > 0)

ZOFFS

Offset from the surface of grid points to the element reference plane.
See comment 7. Overrides the ZOFFS specified on the PSHELL entry.
Default = 0.0 (Real or blank)

Comments
1.

Element identification numbers should be unique with respect to all other element IDs.

2.

Grid points G1 through G8 must be numbered as shown here:

642

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

The element coordinate system is a Cartesian system defined locally for each point ( ,

It is based on the following rules:


- The plane containing
and
-

and

is tangent to the surface of the element.

are obtained by doubly bisecting the lines of constant

increases in the general direction of increasing

Altair Engineering

).

and

of

and

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

643

4.

The orientation of the material coordinate system is defined locally at each interior
integration point by THETA, which is the angle from the line of constant (essentially the
same as the -axis) to the material x-direction (Xmaterial).
If MCID is used in place of THETA, then the local material x-direction (Xmaterial) is
obtained at any point in the element by projection of the x-axis of the prescribed MCID
coordinate system onto the surface of the element at this point. The local z-direction is
aligned with the normal to the surface and the material y-direction (Y material) is
constructed accordingly to produce right-handed local material system X-Y-Zmaterial.

644

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Note that since


changes directions throughout the element based on element shape,
the material coordinate system varies similarly. Because of this, an orthotropic or
anisotropic material will cause the CQUAD8's stiffness to be biased by both its shape and
grid ordering. Use the CQUAD4 element if a constant material coordinate system direction
is desired with orthotropic and anisotropic materials.
5.

T1, T2, T3, and T4 are optional. If they are not supplied, then the element thickness will
be set equal to the value of T on the PSHELL entry. If 0.0 is specified for Ti, then the
thickness at that node is zero. If Tis are supplied, PID cannot reference PCOMP or
PCOMPP data. If the property referenced by PID is selected as a region for Size
optimization, then any Ti values defined here are ignored. If you input Ti for elements in
the design space for Topology or Free-Size optimization, the run will error out.

6.

It is required that the midside grid points be located within the middle third of the edge;
that is the interval (0.25, 0.75) excluding the quarter points 0.25 and 0.75. If the edge
point is located at the quarter point, the program may fail with an error or the calculated
stresses will be meaningless.

7.

The shell reference plane can be offset from the plane defined by element nodes by
means of ZOFFS. In this case all other information, such as material matrices or fiber
locations for the calculation of stresses, is given relative to the offset reference plane.
Similarly, shell results, such as shell element forces, are output on the offset reference
plane.
ZOFFS can be input in two different formats:
1. Real:
A positive or a negative value of ZOFFS is specified in this format. A positive value of
ZOFFS implies that the reference plane of each shell element is offset a distance of
ZOFFS along the positive z-axis of its element coordinate system.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

645

2. Surface:
This format allows you to select either Top or Bottom option to specify the offset
value.
Top:
The top surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 1.

Figure 1: Top option in ZOFFS

Bottom:
The bottom surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 2.

Figure 2: Bottom option in ZOFFS

Note that when ZOFFS is used, both MID1 and MID2 must be specified on the PSHELL
entry referenced by this element (otherwise, singular matrices would result).

646

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Offset is applied to all element matrices (stiffness, mass and geometric stiffness) and to
respective element loads (such as gravity). Hence, ZOFFS can be used in all types of
analysis and optimization in OptiStruct. Automatic offset control is available in composite
free-size and sizing optimization where the specified offset values are automatically
updated based on thickness changes.
However, while offset is correctly applied in geometric stiffness matrix and hence can be
used in linear buckling analysis, caution is advised in interpreting the results. Without
offset, a typical simple structure will bifurcate and loose stability instantly at the critical
load. With offset, though, the loss of stability is gradual and asymptotically reaches a
limit load, as shown below in figure (b):

Hence, the structure with offset can reach excessive deformation before the limit load is
reached. Note that the above illustrations apply to linear buckling in a fully nonlinear
limit load simulation, additional instability points may be present on the load path.
8.

Stresses and strains are output in the local coordinate system identified by
above.

and

9.

Size optimization of the property referenced by PID is not possible if Ti values are defined
here. If the property referenced by PID is selected as a region for free-size optimization,
then any Ti values defined here are ignored.

10. These 2nd order shell elements do not have normal rotational degrees-of-freedom (often
referred to as "drilling stiffness"). No mass is associated with these degrees-of-freedom.
If unconstrained, massless mechanisms may occur. It is therefore advisable to use
PARAM,AUTOSPC,YES when working with these elements.
11. This card is represented as a quad8 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

647

CQUADR
Bulk Data Entry
CQUADR Quadrilateral Element Connection
Description
CQUADR entry is equivalent to CQUAD4. Unlike other Nastran codes, a 6 degree-of-freedom
per node formulation is used for all shell elements.
Refer to the documentation for the CQUAD4 Bulk Data Entry.

648

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CROD
Bulk Data Entry
CROD Rod Element Connection
Description
Defines a tension-compression-torsion element (ROD) of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

C ROD

EID

PID

G1

G2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C ROD

12

13

21

23

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
PID

Identification number of a PROD property entry.


(Integer > 0; If blank defaults to EID)

G1,G2

Grid point identification numbers of connection points.

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Only one ROD element may be defined on a single entry.

3.

This card is represented as a rod element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

649

CSEAM
Bulk Data Entry
CSEAM Seam Weld Element Connection
Description
Define a seam weld connecting two shell surfaces.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C SEAM

EID

PID

SMLN

C TYPE

IDAS

IDBS

IDAE

IDBE

GS

GE

Examples

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C SEAM

22

SEAM1

PSHELL

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

C SEAM

22

ELEM

11

12

21

22

Alternate Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C SEAM

EID

PID

SMLN

C TYPE

IDAS

IDBS

IDAE

IDBE

650

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

Altair Engineering

XS

YS

ZS

XE

YE

ZE

Alternate Format Examples

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C SEAM

22

SEAM1

PSHELL

0.3

0.4

0.25

0.6

0.4

0.25

(1)

(2)

(3)

(4)

(5)

(6)

C SEAM

22

ELEM

0.3

0.4

0.6

0.25

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

(7)

(8)

(9)

(10)

11

12

21

22

0.4

0.25

No default (Integer > 0)


PID

Identification number of a PSEAM entry.


No default (Integer > 0)

SMLN

Identification of a seam line (See comment 2).


No default (Maximum eight characters)

CTYPE

Character string indicating how the connection is defined. Either format


connects up to 3 x 3 quadrilateral shell elements per patch (possibly more
for triangular elements).
For PSHELL type, the connection of surface patch to surface patch is
defined by specifying the property identification numbers.
For ELEM type, the connection of surface patch to surface patch is
defined by specifying element identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

651

Field

Contents

IDAS,
IDBS

Used to define the two connecting patches or the start parts of patch A
and patch B.
If CTYPE="PSHELL", then IDAS and IDBS refer to the property identification
numbers of patch A and patch B.
If CTYPE="ELEM", then IDAS and IDBS refer to the element identification
numbers of patch A and B.

IDAE,
IDBE

Used to define the end parts of patch A and patch B.


If CTYPE="PSHELL", IDAE and IDBE could be zero. If they are not zero,
then IDAE and IDBE refer to the property identification numbers of the end
parts of patch A and patch B. They could be used to define a tailored
blank model.
If CTYPE="ELEM", IDAS and IDBS refer to the element identification
numbers of the end parts of patch A and B.
For PSHELL type, Integer >

GS

Identification number of a grid point which defines the start location of the
connector.
No default (Integer > 0)

GE

Identification number of a grid point which defines the end location of the
connector.
No default (Integer > 0)

XS, YS,
ZS

Coordinates of point that defines the start location (GS) of the seam weld
in the basic coordinate system.
(Real)

XE, YE,
ZE

Coordinates of point that defines the end location (GE) of the seam weld in
the basic coordinate system.
(Real)

652

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

CSEAM defines a flexible connection between two surface patches. With all of the
information provided, a fictitious 8-node CHEXA will be generated internally for a CSEAM,
and the eight corner nodes are all constrained by the grids of corresponding shell
elements. Then the element stiffness of this fictitious CHEXA will be transferred to the
corresponding shell grids. The CSEAM element itself does not hold any independent DOF.
See the figure below:

A CSEAM element connects Shell A and Shell B. A fictitious hexa is generated for the
CSEAM, and the corner nodes of the hexa are all constrained by corresponding shell grids.
To have a clear view, only one of this kind of constraint relationship is shown with dotted
lines.
2.

In the SMLN entry, a name can be given for the CSEAM element. If one CSEAM's GS or
GE is common to the GS or GE of the other CSEAM and they have the same SMLN, the
two CSEAM elements are regarded as neighbors. For two neighboring CSEAM elements,
the faces of the internally generated CHEXAs will be adjusted to form a single common
face.
A seam line does not have a branch with the same SMLN,

3.

The distance between GS and GE is the length of the element. The width of the seam
weld is defined in the PSEAM card as W. It is measured perpendicular to the length and
lies in the plane of Shell A or B.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

653

4.

Building the connectivity for CSEAM.


Since the geometry for finding the correct projection could be various and complicated,
many geometry related checks will be implemented in the following procedure. The
default projection algorithm and checking rules can be modified to some extent via
changing the default value defined in the SWLDPRM card.
To build the connectivity, at first, project GS on Shell A and B; the projection points are
denoted as SA and SB respectively. This is also true for GE, and the projection points are
denoted as EA and EB. SA, SB, EA and EB are also called piercing points. Meanwhile, the
shell elements supporting these piercing points are denoted as EIDSA, EIDSB, EIDEA and
EIDEB.
Take SA as an example. For ELEM type, the program will try to project GS on the user
specified element; if the piercing point falls inside the element, the program will accept it
and move to find the next piercing point. If the piercing point falls outside the element
but within the tolerance defined by PROJTOL in the SWLDPRM card, the program will still
accept it. Otherwise, an error will be issued for this CSEAM element, and the program
continues to process other CSEAM elements. For PSHELL type, the case could be much
more complicated. First, a bunch of shell elements which are the closest ones to GS and
have the user-specified shell property will be selected as candidates. Then project GS on
each of the candidates. If the piercing point falls inside one of the candidates, the
program will accept it and move to find the next one. After looping all the candidates, if
there is no appropriate one to support the piercing point, the tolerance defined by
PROJTOL will be used and all candidates will be searched again. At last, if still no element
is found to support the piercing point, an error will be issued for this CSEAM, and the
program continues to process other CSEAM elements. In this way, all the four piercing
points and elements supporting them are found, or an error is issued.
If GMCHK > 0 (be defined in the SWLDPRM card), various geometry checks will be
implemented at specific steps.
If GMCHK > 0 and GSPROJ > 0.0 (be defined in the SWLDPRM card), the program will
check the angle between the normal vectors of EIDSA and EIDSB, and the angle between
the normal vectors of EIDEA and EIDEB. If the angle is larger than GSPROJ, an error will
be issued for this CSEAM. If GSTOL > 0.0 (be defined in the SWLDPRM card) and one of
the lengths of GS-SA, GS-SB, GE-EA and GE-EB is larger than GSTOL, an error will be
issued. Besides these basic checks, a group of cutout and span checks will be performed
if GMCHK>0.
After the four piercing points are found, the auxiliary points will then need to be located
with the definition of the seam width. Take SA as an example, with the coordinates of
the piercing point, the supporting element EIDSA and the seam weld width W, you can
define the following vector n GS-GE where n is the normal vector of EIDSA. Through
SA, two points SA1 ' and SA2 ' can be defined along this vector and |SA1 '-SA2 '| = W. SA1 '
and SA2 ' are called the preliminary auxiliary points. For a curved or folded shell patch, the
preliminary points may not lie on the shell surface. Therefore, a second projection is
needed to find the final auxiliary points. Take SA1 ' as an example. First, a group of
candidate elements needs to be collected. They are composed of shell elements
surrounding EIDSA. SA1 ' will be projected on each of the candidates to find the best one
to support the projection point. If no element with the user specified shell property is
found with/without tolerance, elements with different shell property will be supplemented
to the candidate list. After projecting all the eight preliminary auxiliary points on the shell

654

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

surfaces, the number of good auxiliary points will be counted. If all of the eight auxiliary
points and corresponding shell elements are successfully located, the building of the
connectivity for this CSEAM succeeds. Otherwise, GSMOVE defined in the SWLDPRM card
will be implemented to avoid the failure if GSMOVE > 0.
When collecting candidate shell elements which will be used to support the auxiliary
points, the angle between the normal vector of the shell element and the thickness
direction of the fictitious CHEXA will be checked. If the angle is larger than GSPORJ, this
shell element will not be considered as a candidate. If EIDSA, EIDSB, EIDEA or EIDEB fails
the check, a warning message will be issued. For curved or folded shell surface, shell
elements on it have more chances to be eliminated from the candidate list, thus may
possibly induce the failure of locating all auxiliary points. One remedy to this problem is to
increase the value of GSPORJ to include more shell elements into the candidate list.

Various projection points generated in building the connectivity for a CSEAM element.
5.

When building the connectivity for CSEAM, if not all eight auxiliary points can be found
and GSMOVE > 0, GS or/and GE will be moved by W/2 and re-projected to avoid the
failure. This often happens near the mesh boundary.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

655

Both GS and GE are moved by W/2 to find correct projection.


6.

For PSHELL type CSEAM, when the GS or GE is close to a folded or curved part of a shell
surface, the program has more chances to fail in locating the correct element to support
the piercing points because of multiple possible choices. In this case, using ELEM type to
directly specify the elements for projection would be a wise alternative.

7.

Check whether the CSEAM spans a cutout or spans more than three shell elements on
each shell surface when GMCHK > 0.
Take EIDSA and EIDEA as an example.
If EIDSA = EIDEA, the seam lies on the same element on this surface. This case is
accepted.
EIDEA and they share at least one common grid, it is necessary to do some
checks.
(In the following check, an element called EIDMA is used to assist the check. EIDMA is
located on the same shell surface where EIDSA and EIDEA are located. It shares one of
the common grids shared by EIDSA and EIDEA. EIDMA could be multiple.)
a)If EIDSA and EIDEA share only one common grid but no EIDMA is found, then this case
is rejected.

656

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

This case is rejected.


b)If EIDSA and EIDEA share only one common grid and at least one EIDMA is found, the
number of free edges will be counted. The following cases are considered.

If there are three or more free edges (bold lines), this case is rejected.

Angle check.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

657

Projection check. M is the middle point of the two free edges' ends.

If there are two free edges, the angle () between the free edges will be calculated. If
the angle is larger than CNRAGLI (be defined in the SWLDPRM card), this case is
accepted. If the angle is smaller than CNRAGLI, then you project the mid-point M to
EIDSA, EIDEA and EIDMA, if the projection point falls inside, this case is still accepted. Or
it will be rejected.

If there is only one free edge, this case is accepted.

If there is no free edge, this case is accepted.

658

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

c)If EIDSA and EIDEA share two common grids, that means EIDSA and EIDEA share a
common edge. Before accepting this case, it is still necessary to check the angle or
project the middle point M.

Angle check.

Projection check. M is the middle point of the two free edges' ends.

Compare the angle () with CNRAGLO even EIDSA and EIDEA share an edge. If the angle
is larger than CNRAGLI, this case is accepted. If the angle is smaller than CNRAGLI, then
you project the mid-point M to EIDSA and EIDEA, if the projection point falls inside, this
case is still accepted. Or it will be rejected.
elements around them and check how these elements are connected with EIDSA and
EIDEA.
(In the following check, EIDMA is re-defined as an element which shares at least one grid
respectively with EIDSA and EIDEA)
a) If there is no EIDMA, this means the CSEAM element spans more than three elements
in the current shell surface, and this case is rejected.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

659

This case is rejected.


b) If there are three EIDMA which share edges with both EIDSA and EIDEA, this case is
accepted.

This case is accepted.


c) If there are two EIDMA which share edges with both EIDSA and EIDEA, it is necessary
to check whether the two EIDMA share a common edge or not. If the two EIDMA do
not share a common edge, there is a cutout and this case is rejected.

660

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

If the two EIDMA do not share a common If the two EIDMA share a common edge, this
edge, there is a cutout and this case is case is accepted.
rejected.
Two different cases when there are two EIDMA who share edges with both EIDSA and
EIDEA.
d) If there is only one EIDMA which shares edges with both EIDSA and EIDEA. The check
presented in the following figure needs to be implemented.

Point M is the average of the two piercing points, that is SA and EA. If the projection
from point M on EIDMA falls inside this element, this case is accepted, or it will be
rejected.
e) If there is only one EIDMA which shares one edge with EIDSA and shares a corner with
EIDEA (or shares one corner with EIDSA and shares one edge with EIDEA), the same
check implemented for the last case will be adopted.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

661

f) If the projection from point M on EIDMA falls inside this element, this case is accepted,
or it will be rejected.
g) If there are two EIDMA and each of them shares an edge with EIDSA or EIDEA and
shares a corner with EIDEA or EIDSA, this case is accepted.

This case is accepted.


h) If there is only EIDMA which shares only corners but no edge with EIDSA or EIDEA, this
case is rejected.

These two cases are rejected. For the one on the right, although there is no cutout on
the surface, but EIDMA is not fully constrained (only two corners are constrained) by the
CSEAM. Therefore, this case is still rejected.
For EIDSB and EIDEB, the same cutout/span check applies.
All the cutout/span checks introduced here still cannot cover 100% cases, but they can
spot most of the bad cases that will lead to unreal modeling of the seam weld. Thus, it is
recommended to turn on the cutout/span check (GMCHK > 0) to exam the seam weld
model in the first round. After all possible problems are resolved, then start the final run.
8.

662

Check whether the CSEAM spans a corner on each shell surface when GMCHK > 0.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Take EIDSA and EIDEA as an example. The angle between the normal vectors of the two
elements should not larger than the value of CNRAGLO (be defined in the SWLDPRM card)
as shown in the following figure. The same check applies to EIDSB and EIDEB. This
prevents generating single CSEAM element across a very curved shell configuration.

If > CNRAGLO, this CSEAM element is rejected.


9.

Diagnostic print outs, checkout runs and non-default setting of search and projection
parameters are requested on the SWLDPRM bulk data entry.

10. It is possible to visualize the fictitious CHEXA via setting SHOWAUX = 1 in the SWLDPRM
card. To have the fictitious CHEXA and corresponding results output into the H3D file,
one also needs to set SHOWAUX = 1.
11. It is recommended to start with default settings and turn on the full geometry check by
setting GMCHK=1 or 2. With the full geometry check, most of the unexpected cases
which may possibly induce unreasonable projections can be spotted. If the switch for
outputting diagnostic info, that is PRTSW, is turned on, the connectivity detail of each
CSEAM element will be printed in the .out file. Also, a summary of various geometry data
will be printed after all CSEAM elements are gone through by the program. They will be
very useful for debugging the seam weld model.
12. Seam weld elements are ignored in heat transfer analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

663

CSEC2
Bulk Data Entry
CSEC2 1D Section Element
Description
Defines a two-noded element used in the definition of arbitrary beam cross-sections.
Format
(1)

(2)

(3)

(4)

(5)

C SEC 2

EID

PID

G1

G2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C SEC 2

71

Field

Contents

EID

Element identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSEC section property entry.


Default = EID (Integer > 0)

G#

Identification number of GRIDS section grid points.


No default (Integer > 0)

Comments
1.

Element identification numbers within a section definition must be unique with respect to
all other element identification numbers within the same section definition.

2.

This entry is only valid when it appears between the BEGIN and END statements.

664

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSEC3
Bulk Data Entry
CSEC3 Triangular Section Element
Description
Defines a 1st order three-noded element used in the definition of arbitrary beam crosssections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

C SEC 3

EID

PID

G1

G2

G3

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

C SEC 3

10

100

Field

Contents

EID

Element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSEC section property entry.


Default = EID (Integer > 0)

G#

Identification number of GRIDS section grid points.


No default (Integer > 0)

Comments
1.

Element identification numbers within a section definition must be unique with respect to
all other element identification numbers within the same section definition.

2.

This entry is only valid when it appears between the BEGIN and END statements.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

665

CSEC4
Bulk Data Entry
CSEC4 Quadrilateral Section Element
Description
Defines a 1st order four-noded element used in the definition of arbitrary beam cross-sections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C SEC 4

EID

PID

G1

G2

G3

G4

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C SEC 4

10

100

Field

Contents

EID

Element identification number.

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSEC section property entry.


Default = EID (Integer > 0)

G#

Identification number of GRIDS section grid points.


No default (Integer > 0)

Comments
1.

Element identification numbers within a section definition must be unique with respect to
all other element identification numbers within the same section definition.

2.

This entry is only valid when it appears between the BEGIN and END statements.

666

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSEC6
Bulk Data Entry
CSEC6 Curved Triangular Section Element
Description
Defines a planar, 2nd order, six-noded element used in the definition of arbitrary beam crosssections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C SEC 6

EID

PID

G1

G2

G3

G4

G5

G6

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C SEC 6

10

100

Field

Contents

EID

Element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSEC section property entry.


Default = EID (Integer > 0)

G#

Identification number of GRIDS section grid points.


No default (Integer > 0)

Comments
1.

Element identification numbers within a section definition must be unique with respect to
all other element identification numbers within the same section definition.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

667

2.

Grid points G1 through G6 must be numbered as shown here:

3.

This entry is only valid when it appears between the BEGIN and END statements.

668

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSEC8
Bulk Data Entry
CSEC8 Curved Quadrilateral Section Element
Description
Defines a planar 2nd order eight-noded element used in the definition of arbitrary beam crosssections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C SEC 8

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C SEC 8

10

100

13

14

15

16

Field

Contents

EID

Element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSEC section property entry.


Default = EID (Integer > 0)

G#

Identification number of GRIDS section grid points.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

669

Comments
1.

Element identification numbers within a section definition must be unique with respect to
all other element identification numbers within the same section definition.

2.

Grid points G1 through G8 must be numbered as shown here:

3.

This entry is only valid when it appears between the BEGIN and END statements.

670

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSET
Bulk Data Entry
CSET Boundary Degrees-of-Freedom of a Superelement Assembly
Description
CSET entry is equivalent to BNDFREE.
Refer to the documentation for the BNDFREE Bulk Data Entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

671

CSET1
Bulk Data Entry
CSET1 Boundary Degrees-of-Freedom of a Superelement Assembly
Description
CSET1 entry is equivalent to BNDFRE1.
Refer to the documentation for the BNDFRE1 Bulk Data Entry.

672

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CSHEAR
Bulk Data Entry
CSHEAR Shear Panel Element Connection
Description
Defines a shear panel element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C SHEAR

EID

PID

G1

G2

G3

G4

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C SHEAR

111

67

89

123

124

56

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

(Integer > 0)
PID

Identification number of a PSHEAR property entry.


(Integer > 0; If blank, defaults to EID)

G1, G2, G3, G4 Grid point identification numbers of connection points.


(Integer > 0; all unique)
Comments
1.

Element identification numbers should be unique with respect to all other element
identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

673

2.

Grid points G1 through G4 must be ordered consecutively around the perimeter of the
element.

3.

All interior angles must be less than 180 degrees.

C SHEAR definition

C SHEAR Element C orner Forces and Shear Flows

4.

Shear panel elements are ignored in heat transfer analysis.

5.

This card is represented as a quad4 element in HyperMesh.

674

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTAXI
Bulk Data Entry
CTAXI Axisymmetric Triangular Element Connection
Description
Defines an axisymmetric triangular cross-section ring element for use in linear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TAXI

EID

PID

G1

G2

G3

G4

G5

G6

(10)

Theta

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TAXI

111

31

74

75

32

51

52

(10)

15.0

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

PID

Identification number of a PAXI entry.


Default = EID (Integer > 0)

G1,G3,G5

Identification numbers of connected corner grid points. Cannot be


omitted.
No default (Integers > 0, all unique)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

675

Field

Contents

G2,G4,G6

Identification numbers of connected edge grid points. Cannot be


omitted.
No default (Integers > 0, all unique)

Theta

Material orientation angle in degrees.


Default = 0.0 (Real)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

All the grid points must be located in the x-z plane of the basic coordinate system with x
= r > 0, and ordered consecutively starting at a corner grid point and proceeding around
the perimeter in either direction.
Corner grid points G1, G3 and G5 must be present. The edge points G2, G4 and G6 are
optional. If any of the edge points are present, they all must be used.

C TAXI definition

676

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

The continuation is optional.

4.

If the PAXI entry referenced in field 3 references a MAT3 entry, material properties and
stresses are always given in the (xm, zm) coordinate system shown in the figure above.

5.

A concentrated load (for example, the load specified on a FORCE entry) at a grid Gi of this
element denotes that applied onto the circumference with radius of Gi. For example, in
order to apply a load of 200N/m on the circumference at Gi which is located at a radius of
0.4m, the magnitude of the load specified on the static load entry must be:
(200 N/m) * 2

* (0.4m) = 502.655N

6.

CTAXI and CTRIAX6 elements cannot be used simultaneously in an input model.

7.

This card is represented as an element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

677

CTETRA
Bulk Data Entry
CTETRA Four-sided Solid Element with four or ten grid points
Description
Defines the connections of the CTETRA element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TETRA

EID

PID

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

C TETRA

112

15

14

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSOLID property entry.


Default = EID (Integer > 0)

G#

Identification numbers of connected grid points.


Default = blank (Integer > 0)

Comments
1.

678

Element ID numbers must be unique with respect to all other element ID numbers.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

The grid points G1, G2, G3, and G4 must describe the vertices and the remaining grid
points describe mid side nodes in the order shown here:
The edge points G5 to G10 are optional. All or none of the edge points can be specified.
It is recommended that the edge points be located within the middle third of the edge.

C TETRA definition

3.

If the user-prescribed node numbering on the bottom face is reversed as compared to the
sequence shown above, then the nodes are renumbered to produce right-handed
orientation of numbering. This is accomplished by swapping node G2 with G3. For 10noded CTETRA, appropriate changes to mid-side node numbering are also performed. In
such cases, the element coordinate system will be built on the renumbered node
sequence.

4.

Stresses are output in the material coordinate system. The material coordinate system is
defined on the referenced PSOLID entry. It may be defined as the basic coordinate
system (CORDM = 0), a defined system (CORDM = Integer > 0), or the element coordinate
system (CORDM = -1).

5.

The element coordinate system for the CTETRA element is defined as follows:
Three intermediate vectors R, S, and T are chosen by the following rules:
R

Joins the midpoints of the edges from G1 to G2 and G3 to G4.

Joins the midpoints of the edges from G1 to G3 and G2 to G4.

Joins the midpoints of the edges from G1 to G4 and G2 to G3

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

679

C TETRA element coordinate system

The origin of the element coordinate system is located at G1.


The element z-axis corresponds to the T vector.
The element y-axis is the cross product of the T and R vectors.
The element x-axis is the cross product of the element y-axis and the element z-axis.
6.

680

This card is represented as a tetra4 or tetra10 element in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTRIA3
Bulk Data Entry
CTRIA3 Triangular Element Connection
Description
Defines a triangular plate element (TRIA3) of the structural model. This element uses a 6
degree-of-freedom per node formulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TRIA3

EID

PID

G1

G2

G3

Theta
or
MC ID

ZOFFS

T1

T2

T3

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

C TRIA3

111

203

31

74

75

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PSHELL, PCOMP, PCOMPP or PHFSHL property


entry.
Default = EID (Integer > 0)

G1,G2,G3

Grid point identification numbers of connection points.


No default (Integers > 0, all unique)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

681

Field

Contents

Theta

Material orientation angle in degrees.


Default = 0.0 (Real)

MCID

Material coordinate system identification number. The x-axis of this


coordinate system is projected onto the element to define the x-axis of
the material coordinate system. If MCID = 0, it specifies the basic
coordinate system. MCID must be an integer > 0. If blank, Theta = 0.0 is
used (See comments 2, 3, and 4).
Default is Theta = 0.0 (Integer > 0)

ZOFFS

Offset from the plane defined by element grid points to the shell reference
plane. See comment 8. Overrides the ZOFFS specified on the PSHELL
entry.
Default = 0.0 (Real or blank)

Ti

Thickness of the element at the grid points. Overrides the thickness


specified on the PSHELL entry. If Ti is specified, the average of all three
thicknesses is used as the element thickness.
For defaults: see comments 5 and 7.
(Real > 0.0 or blank)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

The x-axis of the element coordinate system is aligned with side 1-2 of the shell element.

3.

For H3D and OUTPUT2 output formats, stresses and strains are always output in the
elemental system.

4.

For HM, PUNCH, and OPTI output formats, stresses and strains are output by default in
the material coordinate system. PARAM,OMID can be set to NO to output results in the
elemental system. For elements with blank Theta/MCID, the material coordinate system is
aligned with elemental coordinate system. For elements with prescribed THETA, the
material x-axis is rotated from side G1-G2 by angle THETA. For elements with prescribed
MCID, the material system is constructed by projecting the prescribed MCID onto the
plane of the element.

682

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Orientation when Theta (real value) is entered in 8th field

Orientation when MC ID (integer value) is entered in 8th field

5.

If any of the Ti fields are blank, the thickness specified on the PSHELL data will be used
for that nodes thickness. If 0.0 is specified for Ti, then the thickness at that node is
zero.

6.

If the property referenced by PID is selected as a region for free-size or size optimization,
then any Ti values defined here are ignored. If you input Ti for elements in the design
space for Topology or Free-Size optimization, the run will error out.

7.

If Ti is present, the PID cannot reference PCOMP or PCOMPP data.

8.

The shell reference plane can be offset from the plane defined by element nodes by
means of ZOFFS. In this case all other information, such as material matrices or fiber
locations for the calculation of stresses, is given relative to the offset reference plane.
Similarly, shell results, such as shell element forces, are output on the offset reference
plane.
ZOFFS can be input in two different formats:
1. Real:
A positive or a negative value of ZOFFS is specified in this format. A positive value of
ZOFFS implies that the reference plane of each shell element is offset a distance of
ZOFFS along the positive z-axis of its element coordinate system.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

683

2. Surface:
This format allows you to select either Top or Bottom option to specify the offset
value.
Top:
The top surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 1.

Figure 1: Top option in ZOFFS

Bottom:
The bottom surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 2.

Figure 2: Bottom option in ZOFFS

Note that when ZOFFS is used, both MID1 and MID2 must be specified on the PSHELL
entry referenced by this element (otherwise, singular matrices would result).

684

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Offset is applied to all element matrices (stiffness, mass, and geometric stiffness), and to
respective element loads (such as gravity). Hence, ZOFFS can be used in all types of
analysis and optimization. Note, however, that for first order shell elements (CQUAD4 and
CTRIA3), the offset operation does not correct for secondary effects, such as change of
shell area when offset is applied on curved surfaces. Hence, the value of ZOFFS should
be kept within a reasonable percentage (10% - 15%) of the local radius of curvature.
Automatic offset control is available in composite free-size and sizing optimization where
the specified offset values are automatically updated based on thickness changes.
Moreover, while offset is correctly applied in geometric stiffness matrix and hence can be
used in linear buckling analysis, caution is advised in interpreting the results. Without
offset, a typical simple structure will bifurcate and loose stability instantly at the critical
load. With offset, though, the loss of stability is gradual and asymptotically reaches a
limit load, as shown below in figure (b):

Hence, the structure with offset can reach excessive deformation before the limit load is
reached. Note that the above illustrations apply to linear buckling in a fully nonlinear
limit load simulation, additional instability points may be present on the load path.
9.

PHFSHL properties are only valid with an @HYPERFORM statement in the first line of the
input file.

10. This card is represented as a tria3 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

685

CTRIA6
Bulk Data Entry
CTRIA6 Curved Triangular Shell Element Connection
Description
Defines a curved triangular shell element with six grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TRIA6

EID

PID

G1

G2

G3

G4

G5

G6

THETA
or
MC ID

ZOFFS

T1

T2

T3

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TRIA6

302

31

33

71

32

51

52

45

.03

.020

.025

.025

Field

Contents

EID

Unique element identification number.

(10)

No default (Integer > 0)


PID

Identification number of a PSHELL, PCOMP or PCOMPP entry.


Default = EID (Integer > 0)

G1,G2,G3

Grid point identification numbers of connected corner points.


No default (Integers > 0, all unique)

686

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

G4,G5,G6

Grid point identification number of connected edge points. Cannot be


omitted.
No default (Integer > 0 or blank)

THETA

Material orientation angle in degrees.


Default = 0.0 (Real)

MCID

Material coordinate system identification number. The x-axis of this


material coordinate system is determined by projecting the x-axis of
the MCID coordinate system (defined by the CORDij entry or zero for
the basic coordinate system) onto the surface of the element.
Default is THETA = 0.0 (Integer > 0)

ZOFFS

Offset from the surface of grid points to the element reference plane;
see Comment 7. Overrides the ZOFFS specified on the PSHELL entry.
Default = 0.0 (Real or blank)

Ti

Membrane thickness of element at grid points G1 through G3. The


thickness of the element with Ti specified will be constant and equal to
an average of T1, T2, and T3.
For defaults: see comment 5.
(Real > 0.0 or blank)

Comments
1.

Element identification numbers should be unique with respect to all other element IDs.

2.

Grid points G1 through G6 must be numbered as shown here:

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

687

3.

The element coordinate system is a Cartesian system defined locally for each point ( ,
).

It is based on the following rules:


-

The plane containing

and

is tangent to the surface of the element.

is tangent to the line of constant

increases in the general direction of increasing

688

.
and

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

of

Altair Engineering

4.

The orientation of the material coordinate system is defined locally at each interior
integration point by THETA, which is the angle from the line of constant
(essentially the
same as the -axis) to the material x-direction (Xmaterial).
If MCID is used in place of THETA, then the local material x-direction (Xmaterial) is
obtained at any point in the element by projection of the x-axis of the prescribed MCID
coordinate system onto the surface of the element at this point. The local z-direction is
aligned with the normal to the surface and the material y-direction (Y material) is
constructed accordingly to produce right-handed local material system X-Y-Zmaterial.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

689

5.

T1, T2, and T3 are optional. If they are not supplied, then the element thickness will be
set equal to the value of T on the PSHELL entry. If 0.0 is specified for Ti, then the
thickness at that node is zero. If Ti is supplied, PID cannot reference PCOMP or PCOMPP
data. If the property referenced by PID is selected as a region for Size optimization, then
any Ti values defined here are ignored. If you input Ti for elements in the design space for
Topology or Free-Size optimization, the run will error out.

6.

It is required that the midside grid points be located within the middle third of the edge.
That is the interval (0.25, 0.75) excluding the quarter points 0.25 and 0.75. If the edge
point is located at the quarter point, the program may fail with an error or the calculated
stresses will be meaningless.

7.

The shell reference plane can be offset from the plane defined by element nodes by
means of ZOFFS. In this case all other information, such as material matrices or fiber
locations for the calculation of stresses, is given relative to the offset reference plane.
Similarly, shell results, such as shell element forces, are output on the offset reference
plane.
ZOFFS can be input in two different formats:
1. Real:
A positive or a negative value of ZOFFS is specified in this format. A positive value of
ZOFFS implies that the reference plane of each shell element is offset a distance of
ZOFFS along the positive z-axis of its element coordinate system.
2. Surface:
This format allows you to select either Top or Bottom option to specify the offset
value.

690

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Top:
The top surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 1.

Figure 1: Top option in ZOFFS

Bottom:
The bottom surface of the shell element and the plane defined by the element nodes are
coincident.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
property entry referenced by this element. (The sign of the ZOFFS value would depend on
the direction of the offset relative to the positive z-axis of the element coordinate
system, as defined in the Real section). See Figure 2.

Figure 2: Bottom option in ZOFFS

Note that when ZOFFS is used, both MID1 and MID2 must be specified on the PSHELL
entry referenced by this element (otherwise, singular matrices would result).
Offset is applied to all element matrices (stiffness, mass and geometric stiffness) and to
respective element loads (such as gravity). Hence, ZOFFS can be used in all types of
analysis and optimization. Automatic offset control is available in composite free-size and
sizing optimization where the specified offset values are automatically updated based on
thickness changes.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

691

However, while offset is correctly applied in geometric stiffness matrix and hence can be
used in linear buckling analysis, caution is advised in interpreting the results. Without
offset, a typical simple structure will bifurcate and loose stability instantly at the critical
load. With offset, though, the loss of stability is gradual and asymptotically reaches a
limit load, as shown below in figure (b):

Hence, the structure with offset can reach excessive deformation before the limit load is
reached. Note that the above illustrations apply to linear buckling in a fully nonlinear
limit load simulation, additional instability points may be present on the load path.
8.

Stresses and strains are output in the local coordinate system identified by
above.

and

9.

Size optimization of the property referenced by PID is not possible if Ti values are defined
here. If the property referenced by PID is selected as a region for free-size optimization,
then any Ti values defined here are ignored.

10. These 2nd order shell elements do not have normal rotational degrees-of-freedom (often
referred to as "drilling stiffness"). No mass is associated with these degrees-of-freedom.
If unconstrained, massless mechanisms may occur. It is therefore advisable to use
PARAM,AUTOSPC,YES when working with these elements.
11. This card is represented as a tria6 element in HyperMesh.

692

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTRIAR
Bulk Data Entry
CTRIAR Triangular Element Connection
Description
CTRIAR entry is equivalent to CTRIA3. Unlike other Nastran codes, a 6 degrees-of-freedom
per node formulation is used for all shell elements.
Refer to the documentation for the CTRIA3 Bulk Data Entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

693

CTRIAX6
Bulk Data Entry
CTRIAX6 Axisymmetric Triangular Element Connection
Description
Defines an axisymmetric triangular cross-section ring element for use in linear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TRIAX6

EID

MID

G1

G2

G3

G4

G5

G6

(10)

Theta

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C TRIAX6

111

203

31

74

75

32

51

52

(10)

15.0

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

MID

Identification number of a MAT1 or MAT3 entry.


No default (Integer > 0)

G1,G3,G5

Identification numbers of connected corner grid points. Cannot be


omitted.
No default (Integers > 0, all unique)

694

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

G2,G4,G6

Identification numbers of connected edge grid points. Cannot be


omitted.
No default (Integers > 0, all unique)

Theta

Material orientation angle in degrees.


Default = 0.0 (Real or blank)

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

All the grid points must be located in the x-z plane of the basic coordinate system with x
= r > 0, and ordered consecutively starting at a corner grid point and proceeding around
the perimeter in either direction.
Corner grid points G1, G3 and G5 must be present. The edge points G2, G4 and G6 are
optional. If any of the edge points are present, they all must be used.

C TRIAX6 definition

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

695

3.

The continuation is optional.

4.

If MID is defined on a MAT3 entry, material properties and stresses are always given in
the (xm, zm) coordinate system shown in the figure above.

5.

A concentrated load (for example, the load specified on a FORCE entry) at a grid Gi of this
element denotes that applied onto the circumference with radius of Gi. For example, in
order to apply a load of 200N/m on the circumference at Gi which is located at a radius of
0.4m, the magnitude of the load specified on the static load entry must be:
(200 N/m) * 2

* (0.4m) = 502.655N

6.

CTRIAX6 and CTAXI elements cannot be used simultaneously in an input model.

7.

This card is represented as an element in HyperMesh.

696

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTUBE
Bulk Data Entry
CTUBE Tube Element Connection
Description
Defines a tension-compression-torsion element (TUBE) of the structural model.
Format
(1)

(2)

(3)

(4)

(5)

C TUBE

EID

PID

G1

G2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C TUBE

12

13

21

23

Field

Contents

EID

Element identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
PID

Identification number of a PTUBE property entry.


(Default = EID, Integer > 0)

G1,G2

Grid point identification numbers of connection points.

Comments
1.

Element identification numbers must be unique with respect to all other element
identification numbers.

2.

Only one TUBE element may be defined on a single entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

697

3.

CTUBE data is converted to CROD data as it is read. PTUBE data is converted into PROD
data.

4.

This card is represented as a rod element in HyperMesh.

698

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CVISC
Bulk Data Entry
CVISC Viscous Damper Connection
Description
Defines a viscous damper element.
Format
(1)

(2)

(3)

(4)

(5)

C VISC

EID

PID

G1

G2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

C VISC

64

12

63

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PID

Identification number of a PVISC entry.


Default = EID (Integer > 0)

G1, G2

Geometric grid point identification numbers of connection points.


No default (Integer > 0)

Comments
1.
2.

Element identification numbers must be unique with respect to all other element
identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

699

3.

Only one viscous damper element may be defined on a single entry.

4.

Viscous damper elements are ignored in heat transfer analysis.

5.

This card is represented as a spring element in HyperMesh.

700

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CWELD
Bulk Data Entry
CWELD Weld or Fastener Element Connection
Description
Defines a weld or fastener connecting two surface patches or points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C WELD

EWID

PWID

GS

TYP

GA

GB

SPTYP

GA1/SHIDA

GA2/
SHIDB

GA3

GA4

GA5

GA6

GA7

GA8

GB1

GB2

GB3

GB4

GB5

GB6

GB7

GB8

(7)

(8)

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

C WELD

34

233

GRIDID

55

56

21

22

101

102

378

(1)

(2)

(3)

(4)

(5)

C WELD

34

233

ELEMID

15

16

(6)

(9)

(10)

(9)

(10)

QT

Example 2

Altair Engineering

(6)

(7)

(8)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

701

Example 3

(1)

(2)

(3)

C WELD

34

(4)

(5)

(6)

(7)

ALIGN

103

259

(8)

(9)

(10)

Alternate Formats of CWELD Card PARTPAT/ELPAT


The alternative formats of CWELD listed below are useful in cases when the weld diameter
extends beyond a single shell element. These options connect up to 3x3 shell elements per
patch (possibly more for triangular elements) on each side of weld element.
Format (Alternate)
(1)

(2)

(3)

(4)

(5)

(6)

(7)

C WELD

EWID

PWID

GS

PATC HTYP

GA

GB

PIDA/
SHIDA

PIDB/
SHIDB

XS

YS

(8)

(9)

(10)

ZS

Example 1 (Alternate)

(1)

(2)

(3)

C WELD

10

20

33

34

5.0

5.0

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PARTPAT

0.0

Example 2 (Alternate)

702

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

C WELD

10

20

345

ELPAT

1034

2035

(6)

Field

Contents

EWID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


PWID

Identification number of a PWELD entry.


Default = EWID (Integer > 0)

GS

Identification number of a grid point which defines the location of the


connector. Required when TYP is GRIDID or ELEMID and GA and GB
are unspecified (See comments 2 and 4).
No default (Integer > 0)

TYP

Character string indicating how the connection is defined.


GRIDID indicates that the connection is defined with grid
identification numbers GA# and GB#, respectively (See comment 3).
ELEMID indicates that the connection is defined with shell element
identification numbers SHIDA and SHIDB (See comment 7).
ALIGN indicates that the connection is defined between two shell
vertex grid points (See comment 8).
No default (GRIDID, ELEMID or ALIGN)

GA, GB

When TYP is GRIDID or ELEMID, these represent grid identification


numbers of piercing points on surface A and surface B respectively
(See comment 4).
When TYPE is ALIGN, these represent vertex grid identification
numbers of the first and second shells respectively.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

703

Field

Contents

SPTYP

String indicating types of surface patches A and B. Q indicates


quadrilateral surface patch, and T indicates triangular surface patch.
Required when TYP is GRIDID (See comment 5).
No default (QQ, TT, QT, TQ, Q or T)

GA#

Grid identification numbers of the first surface patch. GA1 to GA3 are
required (See comment 6).
No default (Integer > 0)

GB#

Grid identification numbers of the second surface patch (See


comment 6).

PATCHTYP

The type of connection between the patches. Either format


connects up to 3x3 elements per patch (possibly more for triangular
elements). See comment 12.
For PARTPAT, the connection of surface patch to surface patch is
defined by specifying the property numbers of shells on side A and B,
PIDA and PIDB, respectively.
For ELPAT, the connection of surface patch to surface patch is
defined by specifying IDs of shells SHIDA and SHIDB, respectively.

PIDA,PIDB

Property identification numbers of PSHELL entries defining surface A


and B, respectively. Required for PARTPAT.

SHIDA, SHIDB

Element identification numbers of shells defining weld ends A and B,


respectively. Required for ELPAT.

XS, YS, ZS

Coordinates of point that defines the location of the weld in the basic
coordinate system. It is an alternate way of specifying the location
of GS. Available with PARTPAT/ELPAT options only.
Real

Comments
1.

704

CWELD defines a flexible connection between two surface patches, between a point and
a surface patch, or between two shell vertex grid points. See figure below:

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C onnection between two surface patches

C onnection between a point and a surface patch

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

705

C onnection between two shell vertex grid points

2.

GS is ignored if TYP is ALIGN.

3.

If TYP is GRIDID, either a point to patch (GS to GA#) or a patch to patch (GA# to GB#)
connection is defined. For the patch to patch connection, GA# describes the first
surface patch and GB# describes the second surface patch.

4.

The input of the piercing points GA and GB is optional when TYP is GRIDID and ELEMID. If
GA or GB are not specified, they are generated from the normal projection of GS onto the
surface patches. If GA and/or GB are specified, they take precedence over GS in defining
the respective end points. Also, their locations will be corrected so that they lie on
surface patch A and B, respectively. If GS is not specified, both GA and GB are required.
The length of the connector is the distance from GA to GB.

5.

SPTYP defines the type of surface patches to be connected. SPTYP is required when TYP
is GRIDID to identify quadrilateral or triangular patches. Allowable combinations are:

706

SPTYP

Description

QQ

Connects a quadrilateral surface patch A (QUAD4 or QUAD8) with a


quadrilateral surface patch B (QUAD4 or QUAD8).

QT

Connects a quadrilateral surface patch A (QUAD4 or QUAD8) with a


triangular surface patch B (TRIA3 or TRIA6).

TT

Connects a triangular surface patch A (TRIA3 or TRIA6) with a


triangular surface patch B (TRIA3 or TRIA6).

TQ

Connects a triangular surface patch A (TRIA3 or TRIA6) with a


quadrilateral surface patch B (QUAD4 or QUAD8).

Connects a grid point GB (or GS if GB not provided) with a quadrilateral


surface patch A (QUAD4 or QUAD8). Surface patch B should not be
specified.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

SPTYP

Description

Connects a grid point GB (or GS if GB not provided) with a triangular


surface patch A (TRIA3 or TRIA6). Surface patch B should not be
specified.

GA# are required when TYP is GRIDID. At least 3, and at most 8, grid IDs may be
specified for GA#. Triangular and quadrilateral element definition sequences apply for the
order of GA# and GB#, see below. Missing mid-side nodes are allowed.

Quadrilateral and Triangular Surface Patches as defined when TYP is GRIDID

7.

When TYP is ELEMID, a point to patch connection is defined, GS to SHIDA or a patch to


patch connection, SHIDA to SHIDB. SHIDA and SHIDB must be valid shell element
identification numbers.

8.

When TYP is ALIGN, a point to point connection is defined. GA and GB are required. GA
and GB are not required when TYP is GRIDID or ELEMID.

9.

Forces and moments are output in the element coordinate system (shown in comment 10
below).
The element x-axis points from GA to GB. The element y-axis lies on the plane created by
the element x-axis and the smallest component of the element x-axis is the basic
coordinate system, and is orthogonal to the element x-axis. The element z-axis is the
cross-product of the element x-axis and the element y-axis.

10. The output format of the forces and moments, including the sign convention, is identical
to the CBAR element.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

707

Element coordinate system and sign convention of element forces

11. Diagnostic print outs, checkout runs and non-default setting of search and projection
parameters are requested on the SWLDPRM bulk data entry. It is recommended to start
with default settings.
12. The formats PARTPAT and ELPAT connect shell element patches on side A and B. The
patches are identified by specifying SHIDA and SHIDB (for ELPAT connection) and by
specifying property IDs PIDA and PIDB for PARTPAT connection (wherein SHIDA and SHIDB
are found by appropriate search of best projections of GS (or GA) onto the surfaces A
and B, respectivel)y. The piercing points GA and GB are found by appropriate projections
onto SHIDA and SHIDB. Then the axis GA-GB is used to define four pairs of auxiliary
points GAHi, GBHi, i=1,4 that are located on patches A and B, respectively. The crosssection area of the resulting hexahedral is equivalent to the area of the weld. The weld
stiffness matrix is first built using the auxiliary points and then constrained to supporting
shell nodes using respective shape functions.

708

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

13. Fastener elements are ignored in heat transfer analysis.


14. This card is represented as a rod element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

709

DAREA
Bulk Data Entry
DAREA Dynamic Load Scale Factor
Description
Defines scale (area) factors for dynamic loads. DAREA is used in conjunction with RLOAD1,
RLOAD2, TLOAD1, and TLOAD2 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DAREA

SID

P1

C1

A1

P2

C2

A2

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DAREA

64

5.7

65

5.7

Field

Contents

SID

Identification number.

(9)

(10)

No default (Integer > 0)


P1, P2#

Grid or scalar point identification number.


No default (Integer > 0)

C1, C2#

Component number.
No default (Integer 1 through 6, or 0 for scalar points)

A1, A2#

Scale (area) factor.


No default (Real)

710

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

One or two scale factors may be defined on a single entry.

2.

Refer to RLOAD1, RLOAD2, TLOAD1, or TLOAD2 entries for the formula that define the
scale factor A#.

3.

Component numbers refer to the displacement coordinate system.

4.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

5.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

711

DCOMP
Bulk Data Entry
DCOMP Manufacturing Constraints for Composite Sizing Optimization
Description
Defines manufacturing constraints for composite sizing optimization.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DC OMP

ID

ETYPE

EID1

EID2

EID3

EID4

EID5

EID6

EID7

+
+

LAMTHK

LTMIN

LTMAX

LTSET

LTEXC

PLYTHK

PTGRP

PTMIN

PTMAX

PTOPT

PTSET

PTEXC

PLYPC T

PPGRP

PPMIN

PPMAX

PPOPT

PPSET

PPEXC

BALANC E

BGRP1

BGRP2

BOPT

C ONST

C GRP

C THIC K

C OPT

PLYDRP

PDGRIP

PDTYP

PDSET

PDEXC

PDMAX

Field

Contents

ID

Unique identification number.

PDOPT

(10)

No default (Integer > 0)


ETYPE

Entity type for which this DCOMP card is defined.


No default (PCOMP or STACK)

EID#

Entity identification numbers. List of entities of type ETYPE for which this
DCOMP card is defined.
No default (Integer > 0)

LAMTHK

712

LAMTHK flag indicating that laminate thickness constraints are applied.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Multiple LAMTHK constraints are allowed.

LTMIN

Minimum laminate thickness for the LAMTHK constraint.


Default = blank (Real > 0.0)

LTMAX

Maximum laminate thickness for the LAMTHK constraint.


Default = blank (Real > 0.0 and > LTMIN)

LTSET

Set ID of elements to which the LAMTHK constraint is applied.

LTEXC

Exclusion flag indicates that certain plies are excluded from the LAMTHK
constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PLYTHK

PLYTHK flag indicating that ply thickness constraints are applied. Multiple
PLYTHK constraints are allowed.

PTGRP

Ply orientation in degrees, ply sets or ply IDs, to which the PLYTHK
constraint is applied, depending on the PTOPT selection.
No default (Real or Integer)

PTMIN

Minimum thickness for the PLYTHK constraint.


Default = blank (Real > 0.0)

PTMAX

Maximum thickness for the PLYTHK constraint.


Default = blank (Real > 0.0 and > PTMIN)

PTOPT

Ply selection options for the PLYTHK constraint. Plies can be selected based
on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PTSET

Set ID of elements to which the PLYTHK constraint is applied.

PTEXC

Exclusion flag indicates that certain plies are excluded from the PLYTHK
constraint. The following options are supported:
NONE: Plies are not excluded.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

713

Field

Contents
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PLYPCT

PLYPCT flag indicating that ply thickness percentage constraints are applied.
Multiple PLYPCT constraints are allowed.

PPGRP

Ply orientation in degrees, ply sets or ply IDs, to which the PLYPCT
constraint is applied, depending on the PPOPT selection.
No default (Real or Integer)

PPMIN

Minimum percentage thickness for the PLYPCT constraint.


Default = blank (Real > 0.0 and < 1.0)

PPMAX

Maximum percentage thickness for the PLYPCT constraint.


Default = blank (Real > 0.0, < 1.0 and > PPMIN)

PPOPT

Ply selection options for the PLYPCT constraint. Plies can be selected based
on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PPSET

Set ID of elements to which the PLYPCT constraint is applied.

PPEXC

Exclusion flag indicates that certain plies are excluded from the PLYPCT
constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

BALANCE

BALANCE flag indicating that a balancing constraint is applied. Multiple


BALANCE constraints are allowed.

BGRP1

First ply orientation in degrees, ply sets or ply IDs, to which the BALANCE
constraint is applied, depending on the BOPT selection.
No default (Real or Integer)

BGRP2

Second ply orientation in degrees, ply sets or ply IDs, to which the BALANCE
constraint is applied, depending on the BOPT selection.
No default (Real or Integer)

714

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

BOPT

Ply selection options for the BALANCE constraint. Plies can be selected
based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

CONST

CONST flag indicating that a constant thickness constraint is applied.


Multiple CONST constraints are allowed.

CGRP

Ply orientation in degrees, ply sets or ply IDs, to which the CONST constraint
is applied, depending on the COPT selection.
No default (Real or Integer)

CTHICK

Constant ply thickness for the CONST constraint.


No default (Real > 0.0)

COPT

Ply selection options for the CONST constraint. Plies can be selected based
on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PLYDRP

Indicates that ply drop-off constraints are applied. Multiple PLYDRP


constraints are allowed.

PDGRIP

Ply orientation in degrees, ply sets or ply IDs, to which the PLYDRP
constraint is applied, depending on the PDOPT selection.
No default. (Real or Integer)

PDTYP

Specifies the type of the drop-off constraint as: TOTDRP (see comment 5).

PDMAX

Maximum allowed drop-off for the PLYDRP constraint.


No default (Real > 0)

PDOPT

Ply selection options for the PLYDRP constraint. Plies can be selected based
on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PDSET

Set IDs of elements to which the PLYDRP constraint is applied.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

715

Field

Contents

PDEXC

Exclusion flag indicates certain plies are excluded from the PLYDRP
constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default).
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

Comments
1.

The following manufacturing constraints are available for ply-based composite sizing
optimization:
Lower and upper bounds on the total thickness of the laminate (LAMTHK)
Lower and upper bounds on the thickness of a given orientation (PLYTHK)
Lower and upper bounds on the thickness percentage of a given orientation (PLYPCT)
Manufacturable ply thickness (PLYMAN)
Linking between the thicknesses of two given orientations (BALANCE)
Constant (non-designable) thickness of a given orientation (CONST)
LAMTHK, PLYTHK and PLYPCT can be applied locally to sets of elements. There can be
elements that do not belong to any set.

2.

These constraints are automatically created after performing free-sizing optimization


when the OUTPUT,FSTOSZ control card is activated.

3.

For a more detailed description and an example, refer to the Users Guide section,
Optimization of Composite Structures.

4.

Older versions of the DCOMP card (OptiStruct version 11.0 and prior) are supported and
handled appropriately.

5.

The option for selecting the type of drop-off constraints for PDTYP is defined for a set of
plies, as shown in the figure below:
The option for PDTYP in DCOMP is: TOTDRP.

716

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Assuming that the plies are stacked as shown above, you have the following definition:

6.

This card is represented as an optimization designvariable in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

717

DCONADD
Bulk Data Entry
DCONADD Design Constraint Addition
Description
Creates a combination of several DCONSTR sets that can be referenced by a subcase.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DC ONADD

DC ID

DC 1

DC 2

DC 3

DC 4

DC 5

DC 6

DC 7

DC 8

etc.

Example

(1)

(2)

(3)

(4)

(5)

DC ONADD

101

10

20

30

Field

Contents

DCID

DCONADD identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
DCi

DCONSTR identification number.


(Integer > 0)

Comments
1.

The DCONADD entry is selected by a DESSUB or DESGLB in the Subcase Information


section.

2.

All DCi must be unique.

3.

All DCID must be unique with respect to all Dci (DCONSTR IDs).

4.

This card is represented as an optimizationconstraint in HyperMesh.

718

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DCONSTR
Bulk Data Entry
DCONSTR Design Constraints
Description
Defines design constraint upper and lower bounds where response is defined by DRESP1,
DRESP2, and DRESP3 cards.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DC ONSTR

DC ID

RID

LBOUND/
LTID

UBOUND/
UTID

LFREQ

UFREQ

PROB

(10)

Example

(1)

(2)

(3)

(4)

(5)

DC ONSTR

0.5

10.0

(6)

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

DRESP1

TOPN

DISP

(5)

(6)

(7)

(8)

Field

Contents

DCID

Design constraint identification number.

(9)

(10)

4668

(Integer > 0)
RID

DRESP1, DRESP2, or DRESP3 identification number.


(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

719

Field

Contents

LBOUND/LTID

Lower bound on response or table identification number of a TABLEDi


entry that specifies the lower bound as function of a loading
frequency.
(Real, Integer, or blank)

UBOUND/UTID

Upper bound on response or table identification number of a TABLEDi


entry that specifies the upper bound as function of a loading
frequency.
(Real, Integer, or blank)

LFREQ

Lower bound on a loading frequency range.


Default = 0.0 (Real > 0.0)

UFREQ

Upper bound on a loading frequency range.


Default = 1.0E+20 (Real > LFREQ)

PROB

Probability value for Reliability based Design Optimization runs.


(50.0 < Real < 100.0)

Comments
1.

The DCONSTR DCID is selected in the Subcase Information section by the DESSUB or
DESGLB cards and/or referenced by the DCONADD card.

2.

For any DCID, the associated RID can be referenced only once.

3.

If LBOUND or UBOUND are blank, no constraint will be generated for the bound.

4.

Constraint bounds of zero should be avoided. Unnecessary bounds should be left blank.
For example, lower bounds on von Mises stress should be blank, not zero. If a bound of
zero is input, the bound will be changed to 1.0E-7 for lower bounds and 1.0E-7 for upper
bounds. This will remove numerical difficulties and cause the constraints to be ignored
unless the response is actually very near zero.

5.

LFREQ, UFREQ apply only to response types related to a frequency response subcase
(DRESPi, RTYPE = FRDISP, FRVELO, FRACCL, FRSTRS, FRSTRN, FRFORC, and FRERP). The
constraint bounds LBOUND and UBOUND are applied only if the loading frequency falls
between LFREQ and UFREQ. If ATTB of DRESP1 specifies a frequency value, LFREQ and
UFREQ are ignored.

6.

LTID, UTID identify a loading frequency dependent tabular input using TABLEDi. They are
applied analogous to LFREQ, UFREQ detailed in comment 5.

7.

This card is represented as an optimizationconstraint in HyperMesh.

720

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DDVAL
Bulk Data Entry
DDVAL Discrete Design Variable Values
Description
This bulk data entry can be used to define real, discrete design variable values for discrete
variable optimization or to define relative rotor spin rates in rotor dynamics.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DDVAL

ID

DVAL1

DVAL2

DVAL3

DVAL4

DVAL5

DVAL6

DVAL7

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

DDVAL

ID

DVAL1

"THRU"

DVAL

"BY"

INC

(10)

The continuation entry formats (shown below) may be used more than once, and in any order.
They may also be used with either format above.
Continuation Entry Format 1
(1)

(2)

(3)

(4)

(5)

(6)

DVAL8

DVAL9

DVAL10

DVAL11

-etc.-

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Continuation Entry Format 2


(1)

(2)

(3)

(4)

(5)

(6)

DVAL8

"THRU"

DVAL9

"BY"

INC

Example

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

721

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DDVAL

110

0.1

0.2

0.3

0.5

0.6

0.4

.7

thru

1.0

by

0.05

1.5

20

Field

Contents

ID

Unique discrete value set identification number.

(9)

(10)

(Integer > 0)
DVALi

Discrete values.
(Real or "THRU" or "BY")

INC

Discrete value increment.


(Real)

Comments
1.

DDVAL entries must be referenced by


a) The DDVAL field of a DESVAR bulk data entry.
b) The SPTID field of a RSPINR bulk data entry.

2.

Trailing fields on a DDVAL record can be left blank if the next record is of type DVALi
"THRU" DVALj "BY" INC. Also, fields 7 though 9 must be blank when the type DVALi "THRU"
DVALj "BY" INC is used in fields 2 through 6. Fields 8 through 9 must be blank when the
type DVALi "THRU" DVALj "BY" INC is used in fields 3 through 7 for the first record.
Embedded blanks are not permitted in other cases.

3.

The DVALi sequence can be random.

4.

The format DVALi "THRU" DVALj "BY" INC defines a list of discrete values, for example,
DVALi, DVALi+INC, DVALi+2.0*INC, , DVALj. The last discrete DVALj is always included,
even if the range is not evenly divisible by INC.

5.

This card is represented as a discretedesignvariable in HyperMesh.

722

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DEFORM
Bulk Data Entry
DEFORM Static Element Deformation
Description
Defines enforced axial deformation for one-dimensional elements for use in statics problems.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DEFORM

SID

EID1

D1

EID2

D2

EID3

D3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

DEFORM

21

157

-0.2

111

1.4

(7)

Field

Contents

SID

Identification number of a deformation set.

(8)

(9)

(10)

No default (Integer > 0)


EID#

Element Identification Number. See comment 1.


No default (Integer > 0)

D#

Deformation. (Positive value represents elongation).


No default (Real)

Comments
1.

Only CBAR, CBEAM, CROD, CONROD, and CTUBE elements are valid.

2.

To be used in an analysis, deformation sets must be referenced by a DEFORM Subcase


Information entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

723

3.

DEFORM does not enforce an actual extension of the length of the element; it applies an
internal strain within the element, which produces the specified extension if the element is
free to expand (similar to the effect of thermal expansion).
Since most elements in an FEA model are not free to expand, the specified extension
value may not be achieved because elastic compression of the element will partially or
completely offset the effect of the prescribed strain. To precisely enforce a prescribed
increase in length, MPC equations are more appropriate. Alternatively, giving the DEFORM
element a very high axial stiffness can approximate such conditions.

724

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DELAY
Bulk Data Entry
DELAY Dynamic Load Time Delay
Description
Defines the time delay term in the equations of the dynamic loading function. DELAY is
used in conjunction with RLOAD1, RLOAD2, TLOAD1, and TLOAD2 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DELAY

SID

P1

C1

T1

P2

C2

T2

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DELAY

64

5.7

65

5.7

Field

Contents

SID

Identification number.

(9)

(10)

No default (Integer > 0)


P1, P2

Grid or scalar point identification number.


No default (Integer > 0)

C1, C2

Component number.
No default (Integer 1 through 6, or 0 for scalar points)

T1, T2

time delay term, , for designated point and component.


No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

725

Comments
1.

One or two dynamic load time delays may be defined on a single entry.

2.

SID must also be specified on a RLOAD1, RLOAD2, TLOAD1, or TLOAD2 entry. See those
entry descriptions for the formulae that define the manner in which the time delay term,
, is used.

3.

A DAREA entry should be used to define a load at P# and C#.

4.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

5.

This card is represented as a constraint load in HyperMesh.

726

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DEQATN
Bulk Data Entry
DEQATN Design Equation Definition
Description
Specifies one or more equations for use in optimization.
Format
(1)

(2)

(3)

DEQATN

EQUID

(4)

EQN1;

(5)

(6)

(7)

(8)

EQN2;

EQNn-1;

(9)

(10)

EQN3;

EQNn

Example 1

DEQATN

y(x1, x2) = x1 + x2**-3.0*(2-1)+5.0;

z = -y*1.3E-2

Example 2

DEQATN

104

z(x1, x2) = min(sin(x1), x2);


y = max(0.3, -2.0, z) + 4.0

Field

Contents

EQUID

Unique equation identification number.


(Integer > 0)

EQNi

i-th equation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

727

(Character string)
Comments
1.

All equation identification numbers must be unique.

2.

Each equation card is specified in a fixed format, without the limitation of data field
boundaries. Equations are located in columns 17-72 on the first card, and in columns 972 on each continuation card. There is no limit on the total length of any equation.

3.

Large field format is not allowed.

4.

Free field format is allowed, but only the same number of characters as in the fixed format
(56 on the first line and 64 on the continuation lines) and will be accepted. Characters
after the 72nd column will not be accepted. Excess characters are silently disregarded,
which may result in DEQATN error or in a valid expression different from that intended. On
the continuation card in free format, the comma must be present within the first 8
columns; otherwise, the card will be interpreted in a fixed field format.

5.

Blank characters in the equation have no effect, even within a constant, variable or
function name. Lower and upper case letters are equivalent.

6.

There must be only one variable at the left-hand side of each equation in any equation
card. The variable of the first equation must be followed by an argument list in the
following format:
v1(x1,x2,,xn) = expression(x1,x2,,xn);
v2 = expression(x1,x2,,xn,v1);

vi

= expression(x1,x2,,xn,v1,v2,,vi-1);

vn = expression(x1,x2,,xn,v1,v2,,vn-1);
where, vi is the variable of equation i. (x1, x2, , xn) is the argument list for variable v1.
(v1,v2,,vi-1) is the variable list which corresponds to the result of equation 1 through
equation i-1.
Only the value of the last expression is returned to the bulk data card referencing EQUID
(DRESP2).
7.

Constants can be specified in a format of either integer or floating point. A floating point
number can be in a format of either normal decimal-point format ("3.90") or scientific
notation ("-2.0E-3"), which means -2x10-3.
The list of supported mathematical functions is as follows:

728

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

One-argument functions
abs(x)

absolute value

acos(x)

arccosine

acosh(x)

hyperbolic arccosine

asin(x)

arcsine

asinh(x)

hyperbolic arcsine

atan(x)

arctangent

atanh(x)

hyperbolic arctangent

cos(x)

cosine

cosh(x)

hyperbolic cosine

exp(x)

exponential

log(x)

natural logarithm

log10(x)

common logarithm

pi(x)

multiples of

sin(x)

sine

sinh(x)

hyperbolic sine

int (x)

real to integer conversion

sqrt(x)

square root

Two-argument functions

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

729

Multi-argument functions

8.

730

The supported operators are listed below:


Symbol

Meaning

Example

binary +

x+y

binary -

x-y

multiplication,

x*y

division

x/y

**

power

x**y

unary +

+1.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

9.

Symbol

Meaning

Example

unary -

-1.0

The precedence of mathematical calculations follows the rules of Fortran language.


Parenthesis has a higher priority in the order of precedence than the operators listed in 8.
Two consecutive operators are allowed only if the second one is unary plus or minus.
Examples of operator precedence:
Expression

Result

2**-3

0.128

1 / 2 +3

3.5

2*3-4

2.0

-2**3**2

-512.0

2 + -5

-3.0

2 * -5

-10.0

2 - -5

7.0

2/3/4

0.16666666

2/(3/4)

2.6666666

10. Functions can be defined in a layered format, for example, min(sin(x1), x2). There is no
limit on the number of layers.
11. The DEQATN entry is referenced by DRESP2 and/or DVPREL2 bulk data cards.
DRESP2 card, the variable identified by DVIDi, LABj, NRk, Gr and DPIP correspond to
variable arguments listed in the left-hand side of the first equation of a DEQATN card
identified by EQUID. The variable arguments x1 through xN (where N = n + m + p + q + s)
are assigned in the order DVID1, DVID2, , DVIDn, LAB1, LAB2, , LABm, NR1,NR2, ,
NRp, G1, , Gq, DPIP1,,DPIPS. In a DVPREL2 card, the variables identified by DVIDi and
LABj correspond to variable arguments listed in the left-hand side of the first equation of
a DEQATN card identified by EQUID. The variable arguments x1 through xN (where N = n
+ m) are assigned in the order DVID1, DVID2, , DVIDn, LAB1, LAB2, , LABm.
Only the computed value of the last expression (vn) is used by DRESP2 and/or DVPREL2
entry.
12. This card is represented as an optimizationfunction in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

731

Restrictions
Variable names longer than 8 characters are truncated, which may create an error in
equation if two names are identical after such truncation.
All trigonometric arguments are in radians.
Only alphanumeric characters may be used in variable names (that is do not use
underscores, monetary symbols, punctuation symbols, mathematical operators, letters
from non-English alphabet, and so on).
Mathematical function names (such as those listed in comment 7 above) should not be
used as variable names.
The following functions are not accepted:
DB()
DBA()
INVDB()
INVDBA()
Possible Errors
An informative error message with the DEQATN ID will be displayed if the parsing of the
equation fails. However, in certain cases, the following generic message will be provided:
Error 1690: This equation could not be parsed. See the DEQATN entry in the
OptiStruct manual.
This error message means that it was not possible to clearly identify the reason for the failure.
If this happens, check for the following possible causes, and contact ossupport@altair.com:
The length of the equation exceeds the 72 character per line limitation.
The last character of the equation is an operator.
There are two adjacent operators in the equation.
There are non-alphanumeric characters (besides operators) in the equation.

732

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DESVAR
Bulk Data Entry
DESVAR Design Variable
Description
Defines a design variable.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DESVAR

ID

LABEL

XINIT

XLB

XUB

DELXV

DDVAL

RAND

ITYPE

P1

P2

P3

RANP

ITYPE

P1

P2

P3

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

DESVAR

DV001

0.0

-1.0

1.0

Field

Contents

ID

Unique design variable identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
LABEL

User-defined name for the variable.


(Character)

XINIT

Initial value for variable.


(Real between XLB and XUB)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

733

Field

Contents

XLB

Design variable lower bound.


(Real)

XUB

Design variable upper bound.


(Real)

DELXV

Initial move limit for each design variable.


(Real > 0.0 or blank)
Size: fraction of the variable itself.
(Default = value of DOPTPRM parameter DELSIZ)
Shape: fraction of the range (XUB XLB) of the variable.
(Default = value of DOPTPRM parameter DELSHP)

DDVAL

ID of DDVAL entry that provides a set of discrete values.


(Blank or Integer > 0; Default = blank for continuous design variables)

RAND

Random Design Variable


RAND flag indicating that the random design variable distribution parameters
for Reliability-based Design Optimization (RBDO).

ITYPE

Type of Random Distribution (see comment 5):


(Character string)
NORM Normal distribution
LOG Logarithmic normal distribution
UNIF Uniform distribution
TRIA Triangular distribution
EXPO Exponential distribution
WEIB Weibull distribution
GUMB Gumbel distribution

P1

The first distribution parameter (see comment 5)


(Real > 0.0)

P2

734

The second distribution parameter (see comment 5)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Real > 0.0)

P3

The third distribution parameter (see comment 5)


(Real > 0.0)
Set it to zero, if this parameter does not exist

RANP

Random Parameter
RANP flag indicating that the random parameter distribution parameters for
Reliability-based Design Optimization (RBDO).

Comments
1.

Only the initial value of the move limits can be set. Move limits are automatically
adjusted to enhance iterative stability and convergence speed.

2.

LABEL must begin with an alphabetical character, and cannot have embedded blanks.

3.

If the design variable is discrete (Integer > 0 in DDVAL field), and if either XLB and/or XUB
bounds are wider than those given by the discrete list of values on the corresponding
DDVAL entry, XLB and/or XUB will be replaced by the minimum and maximum discrete
values.

4.

Setting XINIT=XLB=XUB freezes the design variable.

5.

The various distribution types are as follows:


Normal Distribution (NORM)

Log-normal Distribution (LOG)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

735

Uniform distribution (UNIF)

Triangular distribution (TRIA)

Exponential distribution (EXPO)

736

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Weibull distribution (WEIB)

Gumbel distribution (GUMB)

6.

This card is represented as an optimization designvariable in HyperMesh

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

737

DESVARG
Bulk Data Entry
DESVARG Design Variable Group Override
Description
Defines an override for design variable settings.
Format
(1)

(2)

(3)

(4)

(5)

(6)

DESVARG

ID

INIT

LB

UB

SET

Field

Contents

ID

Identification Number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


INIT

Overrides the initial value setting for affected design variables. See
comment 1.
Default = blank (UB, LB, blank, Real or ANALYSIS)

LB

Overrides the lower bound setting for affected design variables.


Default = blank (blank or Real)

UB

Overrides the upper bound setting for affected design variables.


Default = blank (blank or Real)

SET

Defines the design variables that are affected by this DESVARG entry. Can
either be the keyword ALL or the SID of a SET of type DESVAR.
Default = ALL (ALL or Integer)

Comments
1.

738

If any of INIT, LB or UB are left blank, then no override is applied to the corresponding
field on affected DESVARs.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

If INIT is defined as LB, then for all affected DESVAR entries the initial value is set to the
lower bound setting.
Likewise if INIT is defined as UB, then for all affected DESVAR entries the initial value is
set to the upper bound setting.
If, INIT is defined as ANALYSIS, then for all affected DESVAR entries the initialization is
accomplished based on the corresponding analysis properties.
Limitations for the ANALYSIS mode of initialization in the INIT field:
When a Design Variable is associated with multiple properties that have different
values.
When a Design Variable is associated with a property through DVPREL2
When a Design Variable is associated with a property through DVPREL1 with multiple
design variables.
When one of the three limitations occurs, a warning is issued and the Design Variable is
initialized based on the DESVAR card.

3.

Multiple DESVARGs are allowed (DESVARGs are processed in the order of input).

4.

If the bounds are invalid after DESVARG is applied, then an error will occur.

5.

This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

739

DGLOBAL
Bulk Data Entry
DGLOBAL Input Data for Selecting the Global Search Option
Description
Defines input parameters required for the Global Search Option (GSO).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

DGLOBA
L

ID

NGROU
P

NPOINT

SPMETH

NOUTDE
S

DESTOL

MAXSP

MAXSUC
C

MAXWAL
L

MAXC PU

GROUP

SID1

NPOINT1

SPMETH1

GROUP

SID2

NPOINT2

SPMETH2

Field

Contents

ID

Each DGLOBAL card must have a unique ID.

(8)

(9)

(10)

No default (Integer > 0)


NGROUP

Number of groups of design variables. See comment 1.


Default = AUTO (Integer > 0, AUTO or blank)

NPOINT

Number of starting points for each group of design variables. See


comment 1.
Default = AUTO (Integer > 0, AUTO or blank)

SPMETH

740

Method used to generate the starting points. See comment 2.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = OFFSET (EXTREME, OFFSET or blank)

NOUTDES

Number of unique designs to be saved. See comment 4.


Default = ALL (Integer > 0, ALL or blank)

DESTOL

Unique design tolerance. See comment 4.


Default = 1% (Real > 0.0 or blank)

MAXSP

Maximum number of starting points. See comment 5.


Default = 20 (Integer > 0 or blank)

MAXSUCC

Maximum number of consecutive starting points without finding a unique


design. See comment 5.
Default = 10 (Integer > 0 or blank)

MAXWALL

Maximum amount of WALL time (in hours). See comment 5.


Default = infinite (Real > 0.0 or blank)

MAXCPU

Maximum amount of CPU time (in hours). See comment 5.


Default = infinite (Real > 0.0 or blank)

GROUP

GROUP flag indicating that design variables grouping information is to


follow. See comment 3.

SID#

Design variables SET identification number.


No default (Integer > 0)

NPOINT#

Number of starting points for the current group of design variables.


Default = AUTO (Integer > 0, AUTO or blank)

SPMETH#

Method used to generate the starting points for the current group of
design variables.
Default = AUTO (EXTREME, OFFSET, AUTO or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

741

Comments
1.

Design variables are automatically organized in groups, and design variables within a given
group are assigned the same relative starting points, such as their lower or upper bound.
With the AUTO option, OptiStruct determines NGROUP and NPOINT so as to generate a
reasonable and manageable number of starting points. Note that for small optimization
problems, each design variable might be assigned its own group. By default, the number
of groups is equal to the number of independent design variables with an upper limit of 10.
For larger optimization problems, design variables are grouped together in order to
consolidate the potential starting points.

2.

With the EXTREME option, the lower and upper bounds are included in the list of starting
points; whereas with the OFFSET option, the lower and upper bounds are not considered
as starting points. In both cases, the starting points are distributed evenly.

3.

In situations where finer control is required, design variables can be grouped manually by
creating DESVAR SETs. NPOINT# and SPMETH# can also be defined for individual groups.
If those parameters are not defined for a specific group, they inherit their value from the
generic NPOINT and SPMETH parameters.

4.

The unique design tolerance DESTOL provides the threshold under which two designs are
considered identical. It is measured as the average of the relative differences between
the design variables at the last iteration. If such identical designs are found, the best
occurrence is preserved and other results are discarded. Up to NOUTDES unique designs
are saved in subdirectories named <filename_#s_#u>, where #s is the starting point and
#u is the rank of the unique design.

5.

The global search option stops searching for optimal designs when any of the following
criteria has been met:
the maximum number of starting points (MAXSP) has been reached
the maximum number of consecutive starting points without finding a unique design
(MAXSUCC) has been reached
the maximum amount of WALL time (MAXWALL) has been reached or exceeded
the maximum amount of CPU time (MAXCPU) has been reached or exceeded
all possible starting points have been explored

6.

In general, it is recommended to run the global search option with the default parameters,
except for the termination criteria.

7.

The DGLOBAL bulk data entry is referenced by the DGLOBAL command in the I/O section
of the input data.

742

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DIM
Bulk Data Entry
DIM Dimension Definition
Description
Defines a link between a DIM# field on a PBARL or PBEAML property and either the thickness
on a PSEC definition or the y or z coordinate on a GRIDS definition; it is used in the definition
of arbitrary beam cross-sections.
Format
(1)

(2)

(3)

(4)

DIM

DIMID

PID

(5)

(6)

(7)

(8)

(9)

(10)

(6)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

(5)

DIM

DIMID

GID

C OORD

Example

(1)

(2)

(3)

(4)

DIM

10

(5)

(6)

(7)

(8)

(9)

(10)

Field

Contents

DIMID

Dimension identification number. The number of a cross-section dimension


field on a PBARL, or PBEAML property definition.
No default (Integer > 0)

Thickness flag. Indicates that the dimension definition is related to a PSEC


thickness.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

743

Field

Contents

PID

Identification number of a PSEC definition.


No default (Integer > 0)

Grid flag. Indicates that the dimension definition is related to a GRIDS


coordinate.

GID

Identification number of a GRIDS definition.


No default (Integer > 0)

COORD

Coordinate.
No default (Y or Z)

Comments
1.

DIMID may be repeated in a section definition, but a PSEC thickness or a GRIDS


coordinate must not be mentioned on more than one DIM entry within a section definition.

2.

This entry is only valid when it appears between the BEGIN and END statements.

744

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DLINK
Bulk Data Entry
DLINK Design Variable Link
Description
The DLINK bulk data entry defines a link between one design variable and one or more other
design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DLINK

ID

DDVID

C0

C MULT

IDV1

C1

IDV2

C2

IDV3

C3

etc.

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DLINK

55

0.2

0.45

2.0

10

5.5

15

-3.0

Field

Contents

ID

Unique DLINK identification number.

(10)

(Integer > 0)
DDVID

Identification number of the Dependent Design Variable.


(Integer > 0)

C0

Constant.
Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

745

Field

Contents

CMULT

Constant multiplier.
Default = 1.0 (Real)

IDVi

Identification number of the Independent Design Variable.


(Integer > 0)

Ci

Coefficient multiplier for IDVi.


(Real)

Comments
1.

DLINK defines the relationship.

This capability allows physical and non-physical design variables to be related such as
shell thickness and interpolating functions.
2.

Independent IDVis can occur on the same DLINK entry only once.

3.

CMULT and Ci can be used together to provide a simple means of scaling.

4.

This card is represented as an optimization designvariablelink in HyperMesh.

746

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DLINK2
Bulk Data Entry
DLINK2 Design Variable Link Defined by User-supplied Equation
Description
Defines a link of one design variable to one or more other design variables defined by a
DEQATN card. The equation inputs come from the referenced DESVAR values and the
constants defined on the DTABLE card.
Format
(1)

(2)

(3)

(4)

DLINK2

ID

DDVID

EQUID
or FUNC

DESVAR

DVID1

DTABLE

(5)

(6)

(7)

(8)

(9)

(10)

DVID2

DVID3

DVID4

DVID5

DVID6

DVID7

DVID8

DVID9

etc.

LABL1

LABL2

LABL3

LABL4

LABL5

LABL6

LABL7

LABL8

etc.

Example

(1)

(2)

(3)

(4)

DLINK2

201

101

DESVAR

Altair Engineering

(5)

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

747

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

DESVAR

0.0

-1.0

1.0

DESVAR

0.0

-1.0

1.0

DESVAR

0.0

-1.0

1.0

DEQATN

101

(7)

(8)

(9)

(10)

RADIUS(X,Y) = SQRT(X**2+Y**2)

Field

Contents

ID

Relationship identity. Each DVPREL2 card must have a unique ID.


No default (Integer > 0)

DDVID

Identification number of Dependent Design Variable.


(Integer > 0)

EQID

Equation ID of DEQATN data.


No default (Integer > 0)

FUNC

Function to be applied to the arguments. See comment 2.


(Character)

DESVAR

DESVAR flag indicating DESVAR ID numbers follow.

DVIDi

DESVAR ID.
No default (Integer > 0)

DTABLE

DTABLE flag indicating DTABLE labels follow.

LABLi

Constant label on DTABLE card.


No default (Character)

748

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The main application for this entity is to link shape design variables with each other
through equations. DVPREL2 should be used for linking sizing design variables with each
other through equations.

2.

The following functions can be used instead of an EQUID. If FUNC is used, the DEQATN
entry is no longer needed. The functions are applied to all arguments on the DLINK2
regardless of their type.

3.

Function

Description

Formula

SUM

Sum of arguments

AVG

Average of arguments

SSQ

Sum of square of arguments

RSS

Square root of sum of squares of


arguments

MAX

Maximum of arguments

MIN

Minimum of arguments

SUMABS

Sum of absolute value of arguments

AVGABS

Average of absolute value of


arguments

MAXABS

Maximum of absolute arguments

MINABS

Minimum of absolute value of


arguments

This card is represented as an optimization designvariablelink in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

749

DLOAD
Bulk Data Entry
DLOAD Dynamic Load Combination or Superposition
Description
Defines a dynamic loading condition for frequency response problems as a linear combination
of load sets defined via RLOAD1 and RLOAD2 entries, or for transient problems as a linear
combination of load sets defined via TLOAD1 and TLOAD2 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DLOAD

SID

S1

L1

S2

L2

S3

L3

S4

L4

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DLOAD

1.0

2.0

101

2.0

102

2.0

103

-2.0

201

Field

Contents

SID

Load set identification number.

(10)

No default (Integer > 0)


S

Scale factor.
No default (Real)

S#

Scale factors.
No default (Real)

750

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

L#

Load set identification numbers of RLOAD1 and RLOAD2 or TLOAD1 and


TLOAD2 entries.
No default (Integer > 0)

Comments
1.

Dynamic load sets must be selected in the I/O Options or Subcase Information sections
with DLOAD=SID. (See I/O Options and Subcase Information DLOAD entry).

2.

The load vector being defined by this entry is given by:

3.

Each L# must be unique from any other L# on the same entry.

4.

SID must be unique from all RLOAD1 and RLOAD2 or TLOAD1 and TLOAD2 entries.

5.

A DLOAD entry may not reference a set identification number defined by another DLOAD
entry.

6.

RLOAD1 and RLOAD2 loads and TLOAD1 and TLOAD2 loads may be combined only through
the use of the DLOAD entry.

7.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

751

DMIG
Bulk Data Entry
DMIG Direct Matrix Input at Points
Description
Defines direct input matrices related to grid points. The matrix is defined by a single header
entry and one or more column entries. A column entry is required for each column with nonzero elements.
Header Entry Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DMIG

NAME

"0"

IFO

TIN

TOUT

(5)

(6)

(7)

(8)

C1

A1

(9)

(10)

NC OL

Column Entry Format


(1)

(2)

(3)

(4)

DMIG

NAME

GJ

CJ

G1

G2

C2

A2

G3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

DMIG

STIF

DMIG

STIF

27

120

2.5+10

STIF

28

123

4.1+8

DMIG

752

(7)

(8)

(9)

(10)

120

3.+5

123

6.+7

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

NAME

Name of the matrix -- See comment 1.


No default (One to eight alphanumeric characters, the first must be
alphabetic)

IFO

Form of matrix input.


No default (6 = Symmetric, 9 = rectangular)

TIN

Type of matrix being input. (Ignored)


All data is read in as double precision. The number of significant digits is
equal to the number of digits in the input. The input can be free, short fixed
field, or long fixed field data.

TOUT

Type of matrix that will be created. (Ignored)


All data is stored internally as double precision.

NCOL

Number of columns in a rectangular matrix. Must be used when IFO = 9. Not


used when IFO = 6.
Default = blank (Integer > 0, or blank)

GJ

Grid point identification number for column index.


No default (Integer > 0)

CJ

Component number for grid point GJ.


No default (0 < Integer < 6)

Gi

Grid point identification number for row index.


No default (Integer > 0)

Ci

Component number for Gi for a grid point.


No default (0 < CJ < 6)

Ai

Real value of a matrix element.


No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

753

Comments
1.

Matrices may be selected for all solution sequences by the structural matrices before
constraints are applied.

2.

The header entry containing IFO is required. Each no-null column is started with a GJ, CJ
pair. The entries for each row of that column follow. Only non-zero terms need be
entered. The terms may be input in arbitrary order. A GJ, CJ pair may be entered more
than once, but input of an element of the matrix more than once will produce a fatal
message.

3.

Field 3 of the header entry must contain an integer 0.

4.

A given off-diagonal element may be input either below or above the diagonal. While
upper and lower triangle terms may be mixed, a fatal message will be issued if an element
is input both below and above the diagonal.

5.

The matrix names must be unique among all DMIGs.

6.

The recommended format for rectangular matrices requires the use of NCOL and IFO = 9.
The number of columns in the matrix is NCOL. (The number of rows in all DMIG matrices is
always g-set size). The GJ term is used for the column index. The CJ term is ignored.

7.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

8.

The DMIG matrices can be multiplied by real numbers and combined when referenced by
the K2GG, M2GG, K42GG, K2PP, B2GG, and A2GG data.

9.

The DMIG matrices can be multiplied by real numbers as they are assembled into the
global matrices using the PARAM data C2K, CP2, CB2, and CM2 for K2GG, K2PP, B2GG, and
M2GG data respectively.

754

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DMIGMOD
Bulk Data Entry
DMIGMOD H3DDMIG Modification
Description
Defines changes in the contents of a super element from H3DDMIG input.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DMIGMO
D

MTXNAM
E

SHFGID

SHFSPI
D

SHFSPID_
F

SHFC ID

SHFEID

SHFRID

HYBDAM
P

METHOD

SDAMP

KDAMP

METHOD_
F

SDAMP_
F

KDAMP_
F

ORIGIN

A1

A2

A3

GIDMAP

GID1

GID1A

GID2

GID2A

GID3

GID3A

C IDMAP

C ID1

C ID1A

C ID2

C ID2A

C ID3

C ID3A

RELOC

PA1

PA2

PA3

PB1

PB2

PB3

Field

Contents

MTXNAME

Matrix name defined on ASSIGN,H3DDMIG.

(9)

(10)

No default (1 to 6 characters)
SHFGID

All Grid identification numbers in the superelement are shifted by the


specified value. If this field is left blank, then a shift does not occur (see
comment 2).
Default = blank (Integer, or blank)

SHFSPID

All SPOINT identification numbers in the superelement are shifted by the


specified value. If this field is left blank, then a shift does not occur (see

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

755

Field

Contents
comment 2).
Default = blank (Integer, or blank)

SHFSPID_F

All Fluid SPOINT identification numbers in the superelement are shifted by the
specified value. If this field is left blank, then a shift does not occur (see
comment 2).
Default = blank (Integer, or blank)

SHFCID

All Coordinate System identification numbers in the superelement are shifted


by the specified value. If this field is left blank, then a shift does not occur
(see comment 2).
Default = blank (Integer, or blank)

SHFEID

All Element identification numbers in the superelement are shifted by the


specified value. If this field is left blank, then a shift does not occur (see
comment 2).
Default = blank (Integer, or blank)

SHFRID

All Rigid Element identification numbers in the superelement are shifted by


the specified value. If this field is left blank, then a shift does not occur (see
comment 2).
Default = blank (Integer, or blank)

HYBDAMP

Keyword for the remaining data for superelement damping.

METHOD

Identification number of EIGRL card. Hybrid damping would be applied on the


superelements for the modes referred by EIGRL card. If blank, then applied
damping on all the modes.
Default = blank (Integer > 0, or blank)

SDAMP

Identification number of TABDMP1 entry for modal damping.


No default (Integer > 0)

KDAMP

If KDAMP is set to -1, viscous modal damping is entered into the complex
stiffness matrix as structural damping instead of viscous damping.
Default = 1 (Integer)

756

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

METHOD_F

Identification number of EIGRL card. Hybrid damping would be applied on the


fluid part of superelement for the modes referred by the EIGRL card. If
blank, then modal damping is applied damping to all the fluid modes.

SDAMP_F

Identification number of TABDMP1 entry for fluid modal damping of the


superelement.
No default (Integer > 0)

KDAMP_F

If KDAMP_F is set to -1, viscous modal damping is entered into the complex
stiffness matrix as structural damping instead of viscous damping.
Default = 1 (Integer)

ORIGIN

Keyword for defining the new ORIGIN for DMIG.

A1,A2,A3

Defines the new location of the origin of the DMIG.


Default = 0.0 (Real)

GIDMAP

Keyword for defining mapped grid ID pairs.

GIDn,GIDnA

Mapped grid ID pairs.

CIDMAP

Keyword for defining mapped coordinate system ID pairs.

CIDn,CIDnA

Mapped coordinate system ID pairs.

RELOC

Keyword indicating that matching grid point ID pairs in the residual structure
and superelement are to follow (see comment 1).

PA1, PA2,
PA3

IDs of three non-collinear grid points in the residual structure.

PB1, PB2,
PB3

IDs of three non-collinear grid points in the superelement that will be


matched to corresponding grid points in the residual structure (defined by
PA1, PA2 and PA3).

Comments
1.

The RELOC entry and its related fields define three matching grid point pairs on the
residual structure and the superelement. The superelement defined using ASSIGN,
H3DDMIG is relocated (translated and rotated, as required) such that the three non-

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

757

collinear grids PB1, PB2, and PB3 coincide with PA1, PA2, and PA3, respectively on the
residual structure.

Figure 1: Matching three grids on the superelement with grids on the residual structure

2.

758

Identification numbers of certain entities in a superelement can be modified during


H3DDMIG input. Negative integers can be input in the shift fields on this entry (see fields
beginning with SHF above), however, care should be taken to ensure that the
identification numbers are not shifted to negative values. The values of identification
numbers after shifting should always be greater than zero, otherwise, the run will error
out.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOBJREF
Bulk Data Entry
DOBJREF Design Objective for Minmax Problems
Description
Defines a response and its reference values for a minmax (maxmin) optimization problem.
Format
(1)

(2)

(3)

(4)

(5)

DOBJREF

DOID

RID

SID

(6)

NEGREF POSREF
/ LID
/ UID

(7)

(8)

(9)

LOWFQ

HIGHFQ

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

DOBJREF

22

ALL

-1.0

1.0

DOBJREF

22

ALL

-1.0

1.0

(5)

(6)

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

DRESP1

TOP

DISP

488

DRESP1

BOTTOM

DISP

601

Example 2

(1)

(2)

(3)

(4)

(5)

(6)

DOBJREF

23

14

ALL

-1.0

1.0

Altair Engineering

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

759

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

DRESP1

TOP

DISP

488

DRESP1

BOTTOM

DISP

601

Field

Contents

DOID

Design objective identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
RID

DRESP1 or DRESP2 identification number.


(Integer > 0)

SID

Subcase identification number - use ALL if it applies to all subcases.


Default = ALL (Integer > 0, blank or ALL)

NEGREF/ LID

NEGREF
(Real < 0.0)
Default = -1
LID
<Integer>
No default

POSREF/ UID

POSREF
(Real > 0.0)
Default = 1.0
UID
<Integer>
No default

760

Reference value for a negative


response (should always be a
negative real number or blank). See
comments 2, 3 and 5.
Table identification number of a
TABLEDi entry that specifies the
negative reference as a function of
loading frequency. See comments
2, 3 and 5.
Reference value for a positive
response (should always be a
positive real number or blank). See
comments 2, 3 and 5.
Table identification number of a
TABLEDi entry that specifies the
positive reference as a function of
loading frequency. See comments
2, 3 and 5.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

LOWFQ

Lower bound on a loading frequency range.


Default = 0.0 (Real > 0.0)

HIGHFQ

Upper bound on a loading frequency range.


Default = 1.0E+20 (Real > LOWFQ)

Comments
1.

The same DOID can be used for multiple DOBJREF entries. If only one DOID is used, only
one MINMAX=DOID entry is needed in the Subcase Information section.

2.

The use of reference values allows users to set up general minmax problems involving
different responses with different magnitudes. For these problems, the objective can be
defined as:

Minimize max(W1 ( x)/r1, W2 (x)/r 2 , ... Wk ( x)/ rk )


Or, alternatively:

Maximimze max(W1 ( x)/r 1, W2 ( x)/ r2 ,...Wk ( x)/ rk )


where, Wk are response values, and rk are corresponding reference values, which can
take different values depending on whether the response is positive or negative.
3.

Typically, the target value or constraint value of a response can be used as its reference
value. So, instead of the traditional optimization problem where there is a single objective
and multiple constraints, the problem may be formulated as a minmax (maxmin)
optimization, where all the responses which were previously constrained are defined as
objectives and their bounds are used as reference values. This works toward pushing the
maximum ratio of response versus bound value as low as possible, thus increasing the
safety of the structure.

4.

LOWFQ and HIGHFQ apply only to response types related to a frequency response
subcase (DRESPi, RTYPE = FRDISP, FRVELO, FRACCL, FRSTRS, FRSTRN, FRFORC, FRPRES
and FRERP). The reference values NEGREF and POSREF are applied only if the loading
frequency falls between LOWFQ and HIGHFQ. If ATTB of DRESP1 specifies a frequency
value, LOWFQ and HIGHFQ are ignored.

5.

LID and UID identify a loading frequency dependent tabular input using TABLEDi. They are
applied analogous to LOWFQ, HIGHFQ detailed in comment 4.

6.

This card is represented as a designobjectivereference in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

761

DOPTPRM
Bulk Data Entry
DOPTPRM Design Optimization Parameters
Description
Defines design optimization parameters by overriding the defaults.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DOPTPRM

PARAM1

VAL1

PARAM2

VAL2

PARAM3

VAL3

PARAM4

VAL4

PARM5

VAL5

Etc

Example

(1)

(2)

(3)

(4)

(5)

DOPTPRM

MINDIM

10.0

OBJTOL

0.01

(6)

(7)

Field

Contents

PARAMi

Parameter name. See below for allowable names.

VALi

Parameter value.

(8)

(9)

(10)

(Real or Integer)
The available parameters and their values are listed below (click the parameter name for
detailed parameter descriptions).

Parameter

Brief Description

Value

APPROX

Switch to select the approximation


type for stress/strain responses of
shells, composites and 1-D elements.

FULL or REDUCED
Default = FULL

762

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Brief Description

Value

CHECKER

This option controls the


checkerboard-like element wise
density distribution.

0 or 1
Default = 0

DDVOPT

Control options for discrete design


optimization.

1, 2, or 3
Default = 1

DELSHP

The initial fractional move limit for


topography/shape design variables
(fractional difference between the
upper and lower bounds).

Real > 0.0


Default = 0.2

DELSIZ

The initial fractional move limit for


size design variables.

Real > 0
Default = 0.5

DELTOP

The initial fractional move limit for


topology and free-size design
variables.

Real > 0
Default = 0.5

DESMAX or
MAXITER

Defines the maximum number of


design iterations.

Integer > 0
Default = 30, or if MINDIM is
defined, default = 80

DISCRETE

Discreteness parameter. Influences


the tendency for elements in a
topology optimization to converge to
a material density of 0 or 1.

Real > 0.0


Defaults
1.0 general default.
2.0 - for solid dominant
structures with member size
control and no manufacturing
constraints.

DISCRT1D

Discreteness parameter for 1-D


elements.

Real > 0.0


Default = DISCRETE

ESLMAX

Maximum number of outer design


loops in the design of Multi-body
dynamic systems and for nonlinear
optimization using ESLM.

Integer > 0
Default = 30

ESLSOPT

Controls the time step screen


strategy in the design of multi-body
dynamic systems.

<0, 1>
Default = 1

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

763

Parameter

Brief Description

Value

ESLSTOL

Controls the tolerance for screening


out time steps in the design of multibody dynamic systems.

0.0 < Real < 1.0


Default = 0.3

GBUCK

Controls the global buckling


constraint.

YES, NO, 1 or 0
Default = 0

MATINIT

Defines the initial material fraction.

Real between 0.0 and 1.0

MAX_BUCK

Controls the maximum number of


Integer > 0
buckling eigenvalues to be considered Default = 15
for each buckling subcase in an
optimization problem.

MINDENS

Sets the minimum element material


density.

Real > 0.0


Default = 0.01

MINDIM

Specifies the minimum diameter of


members formed in a topology
optimization.

Real > 0.0


Default = no minimum member
size control

MMCHECK

Parameter to ensure a checkerboard- Integer = 0,1


free solution.
Default = 0

NESLEXPD

Specifies the number of time steps


retained for optimization from each
EXPDYN subcase. At each time step,
one ESL is generated.

Integer > 0
Default = 20

NESLIMPD

Specifies the number of time steps


retained for optimization from each
IMPDYN subcase. At each time step,
one ESL is generated.

Integer > 0
Default = 20

NESLNLGM

Specifies the number of time steps


retained for optimization from each
NLGEOM subcase. At each time step,
one ESL is generated.

Integer > 0
Default = 1

OBJTOL

Relative convergence criterion.

Real > 0.0


Default = 0.005

OPTMETH

Options to choose the optimization

MFD, SQP, DUAL, BIGOPT

764

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Brief Description

Value

algorithm.

Default = See descriptions

REMESH

Parameter to activate the remeshing


process.

Integer = 0,1
Default = 0

SHAPEOPT

Optional parameter to select an


alternative shape optimization
algorithm.

<1, 2>
Default = 1

TMINPLY

Defines the minimum ply thickness


allowed for all plies of PCOMPs
selected by DSIZE or DTPL design
variable definitions.

0.0 < Real < min(Ti)

Comments
1.

Some of the parameters may also be defined as separate entities in the I/O section of the
deck, using the previous (OS3.5) input format. Only one definition is allowed.

2.

This card is represented as an opticontrols in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

765

DOPTPRM, APPROX
Parameter

Values

Description

APPROX

< FULL or
REDUCED >
Default =
FULL

Approximation type switch for stress/strain responses for


shells, composites and 1D elements.

766

When REDUCED is chosen, some stress/strain responses will


use the constant force approximation. This method has the
benefit of reducing the memory requirement for large
optimization problems (many stress/strain responses for
many size design variables). Another benefit is the reduction
in runtime if the bottleneck occurs due to sensitivity
analysis. You are encouraged to try the REDUCED option for
the large size optimization model, and, if the FULL option
results in the error 832 (Optimization problem is too big to be
solved by OptiStruct).

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, CHECKER
Parameter

Values

Description

CHECKER

< 0 or 1 >
Default = 0

Checkerboard control option.


Use 0 for no checkerboard control.
Use 1 for global checkerboard control.
This option controls checkerboard-like element wise density
distribution.
The undesired side effect is that a layer of semi-dense
elements will remain at the transition from solid (fully dense
domain) to void. To reduce this side effect, you can
activate minimum member size control (MEMBSIZ on DTPL)
which has built-in checkerboard control.
MINDIM can be smaller than the mesh size if a large member
size is not desired. Minimum member size control has a 3phase iterative process in which the final phase targets the
removal of the semi-dense element layer. If manufacturing
constraints are applied, minimum member size control is
always activated. However, the final iterative phase will not
target the removal of semi-dense elements, as this may
have an adverse effect on manufacturing constraint
preservation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

767

DOPTPRM, DDVOPT
Parameter

Values

Description

DDVOPT

< 1, 2, 3 >
Default = 1

Discrete Design Variable Option.


Use 1 for full discrete design optimization.
Use 2 for two-phased approach, a continuous
optimization phase followed by a discrete optimization
phase (starting from the continuous optimum).
Use 3 for a continuous optimization regardless of DDVAL
definitions. The bounds will be affected by DDVAL if
DDVAL bounds are more restrictive than those defined
on DESVAR.

768

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, DELSHP
Parameter

Values

Description

DELSHP

Real > 0.0


Default = 0.2

Initial fractional move limit for topography/shape design


variables. Defined as the fractional difference between
the upper and lower bounds.
Only the initial value of the move limits can be set.
Move limits are automatically adjusted to enhance
iterative stability and convergence speed.
The move limits for subsequent iterations may not be
greater than this initial move limit.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

769

DOPTPRM, DELSIZ
Parameter

Values

Description

DELSIZ

Real > 0
Default = 0.5

Initial fractional move limit for size design variables.


Only the initial value of the move limits can be set.
Move limits are automatically adjusted to enhance
iterative stability and convergence speed.
The move limits for subsequent iterations may not be
greater than this initial move limit.

770

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, DELTOP
Parameter

Values

Description

DELTOP

Real > 0
Default = 0.5

Initial fractional move limit for topology and free-size


design variables.
Only the initial value of the move limits can be set.
Move limits are automatically adjusted to enhance
iterative stability and convergence speed.
The move limits for subsequent iterations may not be
greater than this initial move limit.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

771

DOPTPRM, DESMAX or MAXITER


Parameter

Values

Description

DESMAX or

Integer > 0
Default = 30
or if MINDIM is
defined, Default =
80

Maximum number of design iterations.

MAXITER

772

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, DISCRETE
Parameter
DISCRETE

Values

Description

Real > 0.0


Defaults
1.0 general
default.
2.0 - for solid
dominant
structures with
member size
control and no
manufacturing
constraints.

Altair Engineering

Discreteness parameter. Influences the tendency for


elements in a topology optimization to converge to a
material density of 0 or 1. Higher values decrease the
number of elements that remain between 0 and 1.
Note: Recommended bounds are 0.0 and 2.0 for shells,
or 3.0 for solids.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

773

DOPTPRM, DISCRT1D
Parameter

Values

Description

DISCRT1D

Real > 0.0


Default = DISCRETE

Discreteness parameter for 1D elements. Same


effect as DISCRETE, but applies only to 1D
elements. It is often desirable to have a higher
discreteness for 1D elements than for 2D or 3D
elements.

774

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, ESLMAX
Parameter

Values

Description

ESLMAX

Integer > 0
Default = 30

Maximum number of outer design loops in the design


of multi-body dynamics systems, and for nonlinear
optimization using the equivalent static load
method.
If 0, then the optimization process is not activated.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

775

DOPTPRM, ESLSOPT
Parameter

Values

Description

ESLSOPT

< 0, 1 >
Default = 1

Controls the time step screen strategy in the design


of multi-body dynamics systems.
1 Screens out time steps that do not play an
important role in the design of multi-body dynamics
systems.
0 Does not screen out time steps. All of the steps
in the multi-body dynamics analysis are involved in
the design process. Refer to Equivalent Static Load
Method (ESLM) for more information.

776

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, ESLSTOL
Parameter

Values

Description

ESLSTOL

0.0 < Real < 1.0


Default = 0.3

Controls the tolerance for screening out time steps


in the design of multi-body dynamic systems. Valid
only when DOPTPRM, ESLSOPT is 1.
The smaller value it has, the smaller number of time
steps the design process handles, which makes the
design process even faster. Too small a value may
cause the design process to diverge though.
Therefore, if the number of time steps retained by
ESLSTOL is less than 10, the 10 most dominant time
steps will be involved in the optimization process. If
the value is 1.0, this is equivalent to DOPTPRM,
ESLSOPT, 0. That is, all of the steps in the multibody dynamic analysis are involved in the design
process, which causes more CPU time to be used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

777

DOPTPRM, GBUCK
Parameter

Values

Description

GBUCK

YES, NO, 1 or 0 Controls global buckling constraint.


Default = 0
Use 0, NO, or omit this parameter for no global buckling
constraint.
Use 1 or YES to activate global buckling constraint.
When activated, the global buckling constraint affects
those subcases in which buckling eigenvalues (LAMA) are
constrained. For these subcases, when this parameter is
activated, only a single buckling mode needs to be
constrained with a lower bound. The GBUCK parameter
will then ensure that all buckling eigenvalues that are
less than or equal to the lower bound defined in this
constraint will be considered within the optimization
problem.
More than one buckling eigenvalue constraint (or if the
single constraint is not a lower bound) in any buckling
subcase will cause termination with an error.
The MAX_BUCK parameter on the DOPTPRM card controls
the maximum number of buckling modes for each subcase
that are considered in the optimization. The EIGRL card
referenced in the buckling subcase controls the number
of modes calculated at each iteration.

778

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, MATINIT
Parameter

Values

Description

MATINIT

Real between
0.0 and 1.0

This parameter declares the initial material fraction. For


topology optimization runs with mass as the objective,
default is 0.9. For runs with constrained mass, the
default is reset to the constraint value. If mass is not
the objective function and is not constrained, the
default is 0.6.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

779

DOPTPRM, MAX_BUCK
Parameter

Values

Description

MAX_BUCK

Integer > 0
Default = 15

Controls maximum number of buckling eigenvalues to be


considered for each buckling subcase in the optimization
problem.
Can only exist if GBUCK exists.
Only up to MAX_BUCK eigenvalues are considered for
each buckling subcase.
If the user-defined MAX_BUCK is less than 15 when auto
screening is turned on, MAX_BUCK will be reset to 15.
If more buckling modes need to be involved for a
problem, explicitly specify MAX_BUCK (MAX_BUCK>15).
To reduce the computational cost, OptiStruct
automatically and dynamically adjusts the upper bound
of the eigenvalue range on the EIGRL card for each
buckling subcase at each iteration and only the
eigenvalues that are possibly retained in the
optimization would be calculated.

780

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, MINDENS
Parameter

Values

Description

MINDENS

Real > 0.0


Default = 0.01

Minimum element material density. Sets a lower limit


on the amount of material that can be assigned to any
design element. Extremely low values for this
parameter can result in an ill-conditioned stiffness
matrix.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

781

DOPTPRM, MINDIM
Parameter

Values

Description

MINDIM

Real > 0.0


Default = no
minimum member
size control

Specifies the minimum diameter of members formed


in a topology optimization. This command is used to
eliminate small members.

782

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, MMCHECK
Parameter

Values

Description

MMCHECK

Integer = 0,1
Default = 0

The use of this parameter, in conjunction with MINDIM,


will ensure a checkerboard-free solution, although with
the undesired side effect of achieving a solution that
involves a large number of semi-dense elements, similar
to the result of using CHECKER=1. Therefore, use this
parameter only when it is necessary.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

783

DOPTPRM, NESLEXPD
Parameter

Values

Description

NESLEXPD

Integer > 0
Default = 20

This parameter specifies the number of time steps


retained for optimization from each EXPDYN subcase.
At each time step, one ESL (equivalent static load) is
generated.
The termination time (TTERM) of the subcase is always
retained.
If 0, all of the time steps are retained.
The total number of time steps is determined by the
duration of the subcase (difference in TTERM between
current and previous subcases) and animation output
control (TA0 and DTA on XSTEP card).
While retaining fewer time steps will result in less
computational time in the inner loop of the ESL method,
very low number of retained time steps could result in
many outer loops required or even divergence of the
solution in the outer loop.

784

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, NESLIMPD
Parameter

Values

Description

NESLIMPD

Integer > 0
Default = 20

This parameter specifies the number of time steps


retained for optimization from each IMPDYN subcase.
At each time step, one ESL (equivalent static load) is
generated.
The termination time (TTERM) of the subcase is always
retained.
If 0, all of the time steps are retained.
The total number of time steps is determined by the
duration of the subcase (difference in TTERM between
current and previous subcases) and animation output
control (TA0 and DTA on TSTEPNX card).
While retaining fewer time steps will result in less
computational time in the inner loop of the ESL method,
a very low number of retained time steps could result in
many outer loops required or even divergence of the
solution in the outer loop.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

785

DOPTPRM, NESLNLGM
Parameter

Values

Description

NESLNLGM

Integer > 0
Default = 1

This parameter specifies the number of time steps


retained for optimization from each NLGEOM subcase.
At each time step, one ESL (equivalent static load) is
generated.
The termination time (TTERM) of the subcase is always
retained.
If 0, all of the time steps are retained.
The total number of time steps is determined by the
duration of the subcase (difference in TTERM between
current and previous subcases) and animation output
control (TA0 and DTA on NLPARMX card).
While retaining fewer time steps will result in less
computational time in the inner loop of the ESL method,
a very low number of retained time steps could result in
many outer loops required or even divergence of the
solution in the outer loop.

786

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, OBJTOL
Parameter

Values

Description

OBJTOL

Real > 0.0


Default = 0.005

Relative convergence criterion. If relative change in


the objective function between two design iterations is
less than OBJTOL, then optimization stops.
A relative change in the objective function of 0.005 is
the same as a 0.5% change in the objective function.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

787

DOPTPRM, OPTMETH
Parameter

Values

Description

OPTMETH

< MFD, SQP,


DUAL, BIGOPT >
Default = See
description and
Note

Options to choose the optimization algorithm:


MFD = Method of feasible directions
SQP = Sequential Quadratic Programming
DUAL = Dual Optimizer based on separable convex
approximation.
BIGOPT = Large scale optimization algorithm.
The DUAL algorithm should be used for concept level
optimization (Topology, free-size and Topography) since
such problems typically involve a very large number of
design variables.
For size and shape optimization, primal methods (MFD
and SQP) and BIGOPT are more suitable since the
approximate problem typically involves coupled terms due
to advanced approximation formulation utilizing
intermediate variables and responses. MFD has been and
remains the default optimizer.
Note:
During a run, the corresponding optimization algorithms
are automatically selected by OptiStruct based on the
optimization type. The use of this parameter will override
the defaults.

788

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, REMESH
Parameter

Values

Description

REMESH

Integer = 0, 1
Default = 0

This parameter specifies if the remeshing process will


be activated when the optimization runs into element
quality error.
1 Yes. When optimization runs into element quality
error, the remeshing process will be activated to
improve element quality. After remeshing is completed,
the optimization process will then continue based on
the remeshed model.
0 No. The remeshing process will not be activated
regardless of whether element quality error occurs.
Note:
1.

When an optimization run results in element quality


error (usually during Shape, Free-shape or
Topography optimization), OptiStruct calls
HyperMesh in batch mode. The model from the
latest optimization iteration is automatically loaded
into HyperMesh and remeshing is performed to
improve element quality.
HyperMesh, then automatically exports a new input
deck named *_rmsh###.fem (### = 001, 002, 003,
represents the remeshing round number) that is
loaded into OptiStruct to continue the optimization
run with the remeshed model.

2.

When an element quality error occurs, OptiStruct


12.0.210 will automatically check the HyperMesh
version.
If HyperMesh version 12.0.110 or later is installed,
the new function *remesh_optistruct will be
called to accomplish the remeshing process. For all
other versions (HyperMesh 12.0 or earlier) an old
function, previously used in 12.0, is called.

3.

Altair Engineering

Installing the latest version of HyperMesh


(12.0.110 or later) is recommended to access all
the latest improvements in the
*remesh_optistruct function.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

789

DOPTPRM, SHAPEOPT
Parameter

Values

Description

SHAPEOPT

Integer = 1, 2
Default = 1

Defines an optional parameter to select an alternative


shape optimization algorithm. This algorithm can be
selected when non-moving shapes are encountered in
the optimization.
1 Default algorithm for shape optimization.
2 Selects the alternate algorithm for shape
optimization.
If discrete design variables are present, it is
recommended to use this parameter along with design
optimization parameter, DDVOPT=2.

790

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DOPTPRM, TMINPLY
Parameter

Values

Description

TMINPLY

0.0 < Real < min(Ti)

Defines the minimum ply thickness allowed for all


plies of PCOMPs selected by DSIZE or DTPL design
variable definitions. Should be smaller than the
minimum of all relevant Ti on the selected PCOMPs.
Check its compatibility with volume constraint if
applied. Note also that for volume fraction
calculation, TMINPLY is not treated as none design
volume in the same way as T0 for regular PSHELLs.
Buckling responses for composite structures may be
considered for free-size and topology optimization
when this parameter is non-zero.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

791

DPHASE
Bulk Data Entry
DPHASE Dynamic Load Phase Lead
Description
Defines the phase lead term in the equation of the dynamic loading function. DPHASE is
used in conjunction with RLOAD1 and RLOAD2 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DPHASE

SID

P1

C1

TH1

P2

C2

TH2

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DPHASE

33

3.4

34

3.4

Field

Contents

SID

Identification number.

(9)

(10)

No default (Integer > 0)


P1, P2

Grid or scalar point identification number.


No default (Integer > 0)

C1, C2

Component number.
No default (Integers 1 through 6, or 0 for scalar points)

TH1, TH2

Phase lead

in degrees.

No default (Real)

792

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

One or two dynamic load phase lead terms may be defined on a single entry.

2.

SID must be referenced on a RLOAD1 or RLOAD2 entry for the formulae that define how
the phase lead is used.

3.

A DAREA entry should be used to define a load at P# and C#.

4.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

5.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

793

DRAPE
Bulk Data Entry
DRAPE Draping Information for Ply-based Composite Definition
Description
Defines the draping data for plies used in ply-based composite definition.
Format
(1)

(2)

(3)

(4)

(5)

DRAPE

ID

DTYPE1

DID1

T1

THETA1

DTYPE2

DID2

T2

THETA2

(6)

(7)

(8)

(9)

(10)

...

Field

Contents

ID

Unique draping identification number.


No default (Integer > 0)

DTYPE#

Entity type.
No default (ELEM, SET, or ALL)

DID#

Entity number. Must refer to an element (for ELEM) or SET (for


SET) bulk data entry. Must be blank for ALL.
No default (Integer > 0 or blank)

T#

Thinning factor.
Default = 1.0 (Real or blank)

THETA#

Angle variation.
Default = 0.0 (Real or blank)

794

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DREPADD
Bulk Data Entry
DREPADD Addition of Response Selection to be Reported without being Constrained
Description
Creates a combination of several DREPORT sets that can be referenced by a subcase.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DREPAD
D

DRID

DR1

DR2

DR3

Dr4

DR5

DR6

DR7

DR8

etc.

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

DREPAD
D

101

10

20

30

Field

Contents

DRID

DREPADD identification number.

(6)

(10)

(Integer > 0)
DRi

DREPORT ID number.
(Integer > 0)

Comments
1.

The DREPADD entry is selected by a REPSUB or REPGLB in the Subcase Information


section.

2.

All DRi must be unique.

3.

All DRID must be unique with respect to all DRi (DREPORT IDs).

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

795

DREPORT
Bulk Data Entry
DREPORT Report Unconstrained Responses
Description
The DREPORT card is used in the bulk data section to report responses, defined by DRESP1,
DRESP2 and DRESP3 cards, to the output file, which are not constrained or used as the
objective function, as defined by the optimization problem.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

DREPOR
T

DRID

RID

LALLOW

UALLOW

NL

NU

(8)

(9)

(10)

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

DREPOR
T

1.0

5.0

(8)

Associated Cards
(1)

(2)

(3)

(4)

DRESP1

TOPN

DISP

(5)

Field

Contents

DRID

Report identification number.

(6)

(7)

(8)

4668

(Integer > 0)
RID

DRESP1, DRESP2, or DRESP3 identification number.


(Integer > 0)

796

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

LALLOW

Optional lower bound on response for reporting purposes.


(Real or blank)

UALLOW

Optional upper bound on response for reporting purposes.


(Real or blank)

NL

Optional number of lowest responses to report. See comment 3.


(Integer or blank)

NU

Optional number of highest response to report. See comment 3.


(Integer or blank)

Comments
1.

The DREPORT DRID is selected in the Subcase Information section by the REPSUB or
REPGLB cards and/or referenced by the DREPADD card.

2.

For any DRID, the associated RID can be referenced only once.

3.

If NL=1, only the lowest response in the range [LALLOW, UALLOW] (if specified) is
reported. If NU=1, only the highest response in the range [LALLOW, UALLOW] (if
specified) is reported.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

797

DRESP1
Bulk Data Entry
DRESP1 Optimization Design Response
Description
A response, or set of responses, that are the result of a design analysis iteration. These
responses can be used as a design objective or as design constraints.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DRESP1

ID

LABEL

RTYPE

PTYPE

REGION

ATTA

ATTB

ATT1

ATT2

EXC L

EID1

EID2

EID3

EID4

EID5

EID6

EID7

EID8

EXTN

(10)

RANDID

Examples

The maximum principal stress in PSHELL PID 1


(1)

(2)

(3)

(4)

(5)

DRESP1

99

SS11

STRESS

PSHELL

(1)

(2)

(3)

(4)

(5)

DRESP1

99

SS11

STRESS

PSHELL

(6)

(7)

(8)

(9)

(10)

or

798

(6)

(7)

(8)

SMP1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

The maximum principal stress in elements 2001-2004


(1)

(2)

(3)

(4)

(5)

DRESP1

88

SS11

STRESS

ELEM

2002

2003

2004

(6)

(7)

(8)

(9)

(10)

2001

The combined mass of PSHELL PID 2, 4, 7


(1)

(2)

(3)

(4)

(5)

DRESP1

77

TMASS

MASS

PSHELL

(6)

(7)

(8)

(9)

SUM

(10)

Field

Contents

ID

Response identification number. Each DRESP1 card must have a unique ID.
No default (Integer > 0)

LABEL

User-defined name for the response.


No default (Character)

RTYPE

Type of response that is defined mass, volume, freq, disp, stress, etc.
No default (See Responses and attributes for DRESP1 card for full list of
response types)

PTYPE

If a property response, then PTYPE is the property type, for example,


PSHELL. It is used in conjunction with ATT1 to identify the unique
property. If an element response, then PTYPE = ELEM. It is used in
conjunction with ATTi to identify the element IDs. For material responses,
PTYPE is MAT and ATTi are material IDs. For grid responses, PTYPE is blank
and ATTi are grid IDs. (See Responses and attributes for DRESP1 card for
further information).
No default (ELEM, MAT, PSHELL, PCOMP, PCOMPG, PLY, PROD, PSOLID,
PELAS, PBAR, PBARL, PBEAM, PBEAML, PFBODY, MBREQM, MBREQE, or
blank)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

799

Field

Contents

REGION

Region identifier.
Default = blank (Integer > 0 or blank, See comment 2)

ATTA,
ATTB

The attributes of a response where further definition is required.


No default (See Responses and attributes for DRESP1 card for further
information)

ATTi

PID, MID, EID, MBREQM ID, MBREQE ID, PFBODY ID or Grid ID as referenced
by PTYPE and RTYPE. (See Responses and attributes for DRESP1 card for
further information).
No default (Integer > 0)

EXCL

EXCL flag indicating that IDs of elements excluded from the response
follow.

EIDi

Element ID. For these elements, no response will be generated.


No default (Integer > 0)

EXTN

EXTN flag indicating that extended attribute definition follows. RANDID is


currently supported as an extended attribute definition and is the RANDPS
ID to which the response applies. See comments 30 and 31.

Responses and Attributes


Center of Gravity and Moment of Inertia Item Codes
Static Stress/Strain Item Codes
Static Stress Item Codes for Bar Elements using PBARL, PBEAML Properties
Static Stress/Strain Item Codes for Composites
Static Failure Item Codes for Composites
Static Force Item Codes
Frequency Response Displacement, Velocity, and Acceleration Item Codes
Frequency Response Pressure Item Codes
Frequency Response Stress/Strain Item Codes
Frequency Response Force Item Codes
PSD/RMS Displacement, Velocity, and Acceleration Item Codes
PSD/RMS Pressure Item Codes
PSD/RMS Stress/Strain Item Codes
MBD Displacement Item Codes

800

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBD Velocity/Acceleration Item Codes


MBD Force Item Codes
Comments
1.

VOLFRAC is equivalent to MATFRAC in previous versions of OptiStruct. MATFRAC is still


supported.

2.

Responses of the same RTYPE with the same region identifier are grouped together into
the same region. If the region identifier is blank, elements identified by an ATTi field
(when PTYPE = ELEM) are grouped together into the same region, but for properties or
materials, each property or material identified by an ATTi field will form its own region.
Refer to the User's Guide section Constraint Screening for a more detailed explanation.
For composite responses (RTYPE = CSTRESS, CSTRAIN, CFAILURE; PTYPE = PCOMP,
PCOMPG), each ply is given its own region. However, if a region identifier is defined
explicitly for the entire lay-up (ATTB=ALL), this region identifier applies to all plies. It is
not recommended to do this.

3.

DRESP1 entries must have unique identification numbers with respect to DRESP2 and
DRESP3 entries.

4.

In normal modes analysis, the frequencies are in Hz (cycles/time).

5.

The total displacement can be requested using ATTA=7; the total rotation using ATTA=8.

6.

PTYPE = PCOMP, PCOMPG can be selected for RTYPE = STRESS or RTYPE = STRAIN, in
which case homogenized stresses or strains are used. RTYPE = CSTRESS or RTYPE =
CSTRAIN should be used instead for composite responses.

7.

Stresses are element stresses. For CBAR, CBEAM, stresses are normal (axial) stresses for
the element.

8.

VOLFRAC and MASSFRAC can only be applied to topology design domains. OptiStruct will
terminate with an error if this is not the case.

9.

MASS, MASSFRAC, COG and INERTIA responses are not available for PBUSH, PDAMP,
PELAS, PGAP, PVISC, and PWELD.

10. VOLUME and VOLFRAC responses are not available for CONM2, PDAMP, PELAS, PGAP,
PMASS, and PVISC.
11. The VOLUME of a single CWELD element is 1.0. The response then is the number of
welds.
12. WCOMP, WFREQ, COMB require the definition of WEIGHT and/or MODEWEIGHT subcase
commands. If WEIGHT or MODEWEIGHT are not defined, the following defaults apply:
RTYPE

Applicable subcase commands Default

WCOMP

WEIGHT in static subcases

WEIGHT = 1.0 for all static subcases.

WFREQ

MODEWEIGHT in normal modes


subcase

MODEWEIGHT (1) = 1.0 in most cases for


topology optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

801

RTYPE

Applicable subcase commands Default


MODEWEIGHT (7) = 1.0 if no SPC is
defined for the subcase, EIGRL does not
define a V1 > 0.0, and it is solving for
more than 6 modes or all modes below an
upper bound.

COMB

WEIGHT in static subcases

WEIGHT = 1.0 for all static subcases.

MODEWEIGHT in normal modes


subcase
13. CSTRESS, CSTRAIN, and CFAILURE are only available for PCOMP, PCOMPG.
ATTB = # refers to a ply on a PCOMP.
Example: DRESP1, 12, PLY23, CSTRESS, PCOMP, SMAP, 23, 43.
ATTB = G# refers to a global ply on a PCOMPG.
Example: DRESP1, 12, GLOBAL11, CFAILURE, PCOMPG, HILL, G11, 17.
ATTB must be blank for PLY response type.
14. STRAIN responses not applicable for CELAS.
15. Composite Stress/Strain item codes S1Z and S2Z for Shear-1Z and Shear-2Z are for
CSTRESS only, these are not available for CSTRAIN.
16. Lower bound constraints are not allowed on von Mises stress.
17. LABEL must begin with an alphabetical character.
18. Responses that do not exist are ignored, and a warning is issued.
19. EXCL only applies to RTYPE = STRESS, STRAIN, FORCE, CSTRESS, CSTRAIN, CFAILURE,
FRSTRS, FRSTRN, and FRFORC response types.
20. For RTYPE = MASS, MASSFRAC, VOLUME, VOLFRAC, COG, INERTIA, BEADFRAC, and
COMP; ATTi can only be blank if PTYPE is also blank. ATTi blank means that all relevant
entities are included. They all belong to the same region for constraint screening.
21. For RTYPE=STRESS, STRAIN, FORCE, FRSTRS, FRSTRN, FRFORC, CSTRESS, CSTRAIN, and
CFAILURE; ATTi can only be blank if PTYPE is a property type (not allowed when PTYPE is
"ELEM"). ATTi blank means that all entities of the defined PTYPE are selected.
22. For RTYPE = MASS, MASSFRAC, MBMASS, VOLUME, VOLFRAC, COG, MBCOG, INERTIA,
MBINER, COMP, and BEADFRAC; ATTB = COMB results in the creation of a single response
for the combination of all ATTi entities.
23. For RTYPE=MASS, MBMASS, VOLUME, MBCOG, MBINER, COMP, MASSFRAC, and VOLFRAC;
ATTB=SUM is the same as ATTB=COMB.
24. For RTYPE = FRDISP, FRVELO, FRACCL, FRSTRS, FRSTRN, FRFORC, FRERP, PSDDISP,
PSDVELO, PSDACCL, and PSDPRES the following functions can be applied through the
character input on ATTB. The formulas are applied across all loading frequencies. The
use of MAX can be very inefficient computationally and it is better to leave ATTB blank
and let constraint screening take care of it.

802

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Function

Description

SUM

Sum of arguments

AVG

Average of arguments

SSQ

Sum of square of arguments

RSS

Square root of sum of squares of


arguments

MAX

Maximum of arguments

MIN

Minimum of arguments

SUMABS

Sum of absolute value of


arguments

AVGABS

Average of absolute value of


arguments

MAXABS

Maximum of absolute arguments

MINABS

Minimum of absolute value of


arguments

Formula

25. For RTYPE = INERTIA, the Moment of Inertia is with reference to the center of gravity.
The Moment of Inertia of the whole model is referred to the center of gravity of the whole
model. The Moment of Inertia of each property or material is referred to the center of
gravity of that property or material.
26. For acoustic optimization, pressure responses are defined using RTYPE=FRPRES; however,
it is acceptable to define a pressure response on a fluid grid as RTYPE=FRDISP with ATTA
as one of M-TX, R-TX or I-TX, internally it will be converted to FRPRES (with M-TX/R-TX/
I-TX interpreted as M-PRES/R-PRES/I-PRES). Likewise, RTYPE=PSDDISP or RMSDISP are
accepted in place of PSDPRES or RMSPRES, respectively.
27. For RTYPE = MBDIS, MBVEL, MBACC, or MBFRC, the PTYPE must be MBREQM. These four
response types must be defined using MARKERs, and requested by MBREQM. For RTYPE =
MBEXPR, the PTYPE must be MBREQE. The response must be requested by MBREQE. For

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

803

RTYPE = MBMASS, MBCOG, or MBINER, the PTYPE must be PFBODY.


28. MBREQE referenced in DRESP1 must have single expression although MBREQE allows up to
6 expressions for analysis output.
29. MBD system level responses must be scalar quantities. Thus, THE ATTB field must have
one of the following - MAX, MIN, MAXABS, or MINABS so that time dependent vectors can
be converted to scalar quantities.
30. Legacy data with RANDPS ID defined on the PTYPE or ATTB entry is also supported.
31. A blank field for RANDID on the EXTN extended attributes entry indicates that all RANDPS
cards in the input file will be used.
32. Cluster Size represents the number of elements around the specified element whose
stress contributions are included in the calculation of the individual elements stress
contribution. The contributions of the elements in the cluster are weighted based on their
distance to the center of the cluster (Available for Shell and Solid elements). Weighting
element stress contributions using Cluster Size is generally useful in models with stress
gradients or stress concentrations in the design space. If the stress distribution within
the selected element cluster is uniform, there may not be any significant difference in the
stress response. A separate result type Element Stress Cluster is available in the
_s#.h3d file and stress results based on element cluster response(s) can be viewed in
HyperView by selecting Element Stresses Cluster in the Result type: drop-down menu.
33. This card is represented as an optimization response in HyperMesh.

804

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - Responses and Attributes


Response
s

RTYPE

PTYPE

ATTA

ATTB

ATTi

EXTN

MASS

PTYPE,
"MAT", or
blank

COMB**, SUM
or blank

PID, MID or
blank*

Fraction of MASSFR PTYPE,


mass
AC
"MAT", or
blank

COMB**, SUM,
or blank

PID, MID or
blank*

Volume

Mass

VOLUME

PTYPE,
"MAT", or
blank

COMB**, SUM
or blank

PID, MID or
blank*

Fraction of VOLFRA
design
C
volume

PTYPE,
"MAT", or
blank

COMB**, SUM,
or blank

PID, MID or
blank*

Center of
Gravity

PTYPE,
"MAT", or
blank

Center of
Gravity item
code

COMB**
or blank

PID, MID or
blank*

Moment of INERTIA PTYPE,


Inertia
"MAT", or
blank

Moment of
Inertia item
code

COMB**
or blank

PID, MID or
blank*

COG

Complianc
e of a
static
subcase

COMP

PTYPE,
"MAT", or
blank

COMB**, SUM
or blank

PID, MID or
blank*

Static
displaceme
nt

DISP

Static
displacement
Component

Grid ID

Mode
shape

DISP

Component

Mode #

Grid ID

Frequency
of a
normal
mode

FREQ

Normal mode #

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

805

Response
s

RTYPE

PTYPE

ATTA

ATTB

ATTi

EXTN

LAMA

Buckling mode
#

Static
STRESS
stress of
homogeno
us material

PTYPE or
"ELEM"

Static stress
item code

Cluster Size
****** or
blank

PID, EID
or blank***

Static
STRAIN
strain of
homogeno
us material

PTYPE or
"ELEM"

Static strain
item code

PID, EID
or blank***

Static
stress in a
composite
lay-up

CSTRES "PCOMP",
S
"PCOMPG"
, "PLY",
or "ELEM"

Composite
Stress item
code

ALL, Ply No.


or G#****
(Default = 1)
or blank*****

PID, EID, Ply


ID,
or blank***

Static
strain in a
composite
lay-up

CSTRAI "PCOMP",
N
"PCOMPG"
, "PLY",
or "ELEM"

Composite
Strain item
code

ALL, Ply No.


or G#****
(Default = 1)
or blank*****

PID, EID, Ply


ID,
or blank***

Static
failure in a
composite
lay-up

CFAILU
RE

"PCOMP",
"PCOMPG"
, "PLY",
or "ELEM"

Composite
Failure item
code

ALL, Ply No.


or G#****
(Default = 1)
or blank*****

PID, EID, Ply


ID,
or blank***

Static
force

FORCE

PTYPE or
"ELEM"

Static force
item code

PID, EID
or blank***

Frequency
response
displaceme
nt

FRDISP

Frequency
Response
displacement
component

Frequency Value.
(Blank, Real >
0.0 or Character)

Grid ID

Frequency
response
velocity

FRVELO

Frequency
Response
velocity
component

Frequency Value
(Blank, Real >
0.0 or Character)

Grid ID

Eigenvalue
of a
buckling
mode

806

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Response
s

RTYPE

Frequency FRACCL
response
acceleratio
n

PTYPE

ATTA

ATTB

ATTi

EXTN

Frequency
Response
acceleration
component

Frequency Value
(Blank, Real >
0.0 or Character)

Grid ID

Frequency
response
stress

FRSTRS

PTYPE
or
"ELEM"

Frequency
Response
Stress item
code

Frequency Value
(Blank, Real >
0.0 or Character)

PID, EID
or blank***

Frequency
response
strain

FRSTRN

PTYPE
or
"ELEM"

Frequency
Response
Strain item
code

Frequency Value
(Blank, Real >
0.0 or
Character)

PID, EID
or blank***

Frequency
response
force

FRFORC

PTYPE
or
"ELEM"

Frequency
Response
Force item
code

Frequency Value
(Blank, Real >
0.0 or Character)

PID, EID
or blank***

Frequency
response
equivalent
radiated
power

FRERP

Frequency Value
(Blank, Real >
0.0 or Character)

Panel ID

FRPRES

M-PRES, RPRES or IPRES

Frequency Value.
(Blank, Real >
0.0 or Character)

Grid ID

PSD
PSDDIS
displaceme
P
nt

PSD/RMS item Frequency Value.


(Blank, Real >
code

GRID ID

RANDPS
ID

PSD
velocity

PSDVEL
O

PSD/RMS item
(Blank, Real >
code
0.0 or Character)

GRID ID

RANDPS
ID

PSD
PSDACC
acceleratio
L
n

PSD/RMS item Frequency Value.


(Blank, Real >
code

GRID ID

RANDPS
ID

PSD stress PSDSTR


S

PTYPE
or

PID, EID
or blank***

RANDPS
ID

Acoustic
pressure

Altair Engineering

0.0 or Character)
Frequency Value.

0.0 or Character)

PSD/RMS item
code

Frequency
Value

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

807

Response
s

RTYPE

PTYPE

ATTA

"ELEM"

ATTB

ATTi

EXTN

(Blank, Real >


0.0 or
Character)

PSD strain

PSDSTR
N

PTYPE
or
"ELEM"

PSD/RMS item
code

Frequency
Value
(Blank, Real >
0.0 or
Character)

PID, EID
or blank***

RANDPS
ID

PSD
pressure

PSDPRE
S

PRES

Frequency
Value.
(Blank, Real >
0.0 or
Character)

GRID ID

RANDPS
ID

RMS
RMSDIS
displaceme
P
nt

PSD/RMS item
code

GRID ID

RANDPS
ID

RMS
velocity

RMSVEL
O

PSD/RMS item
code

GRID ID

RANDPS
ID

RMS
acceleratio
n

RMSAC
CL

PSD/RMS item
code

GRID ID

RANDPS
ID

RMS stress RMSSTR


S

PTYPE
or
"ELEM"

PSD/RMS item
code

PID, EID
or blank***

RANDPS
ID

RMS strain RMSSTR


N

PTYPE
or
"ELEM"

PSD/RMS item
code

PID, EID
or blank***

RANDPS
ID

RMSPRE
S

PRES

GRID ID

RANDPS
ID

Static
WCOMP
compliance
weighted
across all

RMS
pressure

808

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Response
s

RTYPE

PTYPE

ATTA

ATTB

ATTi

EXTN

Frequency
weighted
across
reciprocal
eigenvalue
s

WFREQ

Combined
static
compliance
and
frequency
index
(Combined
Complianc
e Index)

COMB

Bead
discretene
ss fraction
for
topograph
y design
space
(0.0 <
BEADFRAC
< 1.0)

BEADFR
AC

COMB** or
blank

DTPGID
or blank*

MBD
displaceme
nt

MBDIS

MBREQM

MBD
Displacement
item code

MAX, MIN,
MAXABS,
MINABS

MBREQM ID

MBD
velocity

MBVEL

MBREQM

MBD Velocity
item code

MAX, MIN,
MAXABS,
MINABS

MBREQM ID

MBD
acceleratio
n

MBACC

MBREQM

MBD
Acceleration
item code

MAX, MIN,
MAXABS,
MINABS

MBREQM ID

MBD force

MBFRC

MBREQM

MBD Force

MAX, MIN,

MBREQM ID

subcases

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

809

Response
s

RTYPE

PTYPE

ATTA

ATTB

item code

MAXABS,
MINABS

ATTi

EXTN

MBD
expression

MBEXPR

MBREQE

MBREQE ID

Mass of
flexible
body

MBMAS
S

PFBODY

COMB, SUM or
blank

PFBODY ID

Center of
gravity of
flexible
body

MBCOG

PFBODY

Center of
Gravity item
code

COMB, SUM or
blank

PFBODY ID

Moment of
inertia of
flexible
body

MBINER

PFBODY

Moment of
Inertia item
code

COMB, SUM or
blank

PFBODY ID

Fatigue
results

FATIGU
E

PTYPE or
"ELEM"

LIFE, DAMAGE
or FOS

PID, EID or
blank***

TEMP

Grid ID

SPCFOR
CE

Grid ID

GPFORC
E

Grid ID

EID

Temperatu
re
SPC
Forces
(Reaction
forces/
moments)
Grid point
force
balance
results

Component ID
(1-6)
Degrees of
Freedom

Component ID
(1-6)
Degrees of
Freedom

ATTi can only be blank when PTYPE is also blank, and means that all relevant
entities will be included. See comment 20 on the DRESP1 page.

**

ATTB = COMB Response represents a single response for the combination of all

810

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Response
s

RTYPE

PTYPE

ATTA

ATTB

ATTi

EXTN

ATTi entities. See comment 22 on the DRESP1 page.


***

ATTi can only be blank when a property type is defined in the PTYPE field (not
allowed for "ELEM"), and means that all entities of the defined property type will
be selected. See comment 21 on the DRESP1 page.

****

ATTB = G# # is the number of the global ply defined on a PCOMPG. See


comment 13 on the DRESP1 page.

*****

ATTB must be Blank for PLY response type. See comment 13 on the DRESP1
page.

******

ATTB = Cluster Size represents the number of elements in a cluster for which
Stress Constraints need to be defined. See comment 32 on the DRESP1 page.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

811

DRESP1 - Static Stress/Strain Item Codes


Element

Stress/Strain Item

ASCII Code

Number Code *

CELAS

Stress/Strain

CROD

Both ends

SAB

End A

SA

End B

SB

All stresses/strains

SALL

End A pt. C

SAC

End A pt. D

SAD

End A pt. E

SAE

End A pt. F

SAF

End B pt. C

SBC

10

End B pt. D

SBD

11

End B pt. E

SBE

12

End B pt. F

SBF

13

Max end A

SAMAX

Max end B

SBMAX

14

CBAR**

812

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CBEAM**

All stresses/strains

SALL

End A pt. C

SAC

End A pt. D

SAD

End A pt. E

SAE

End A pt. F

SAF

End B pt. C

SBC

104

End B pt. D

SBD

105

End B pt. E

SBE

106

End B pt. F

SBF

107

Max end A

SAMAX

Max end B

SBMAX

108

CSHEAR

All Solid
elements

Maximum Shear

SHMAX

Average Shear

SHAVG

Safety Margin

SHMRG

von Mises

SVM

Max Principal Stress

SMP

Major Principal

SMAP

Mid Principal

SMDP

16

Altair Engineering

13

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

813

All Shell
elements

814

Minor Principal

SMIP

22

Normal X

SXX

Normal Y

SYY

14

Normal Z

SZZ

20

Shear XY

SXY

Shear YZ

SYZ

15

Shear XZ

SXZ

21

Equivalent Plastic Strain

PLAS

von Mises both surfaces

SVMB

Major Principal both


surfaces

SMPB

von Mises 1

SVM1

von Mises 2

SVM2

17

Major Principal 1

SMP1

Major Principal 2

SMP2

15

Minor Principal both


surfaces

SMIPB

Minor Principal 1

SMIP1

Minor Principal 2

SMIP2

16

Normal X both surfaces

SXB

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Normal X 1

SX1

Normal X 2

SX2

11

Normal Y both surfaces

SYB

Normal Y 1

SY1

Normal Y 2

SY2

12

Shear XY both surfaces

SXYB

Shear XY 1

SXY1

Shear XY 2

SXY2

13

Equivalent Plastic Strain


both surfaces

PLASB

Equivalent Plastic Strain 1

PLAS1

Equivalent Plastic Strain 2

PLAS2

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.
**For Bar elements that reference PBARL, PBEAML, it is recommended that the special stress
item codes listed under Stress Item Codes for Bar Elements using PBARL, PBEAML Properties be
used. Stress/strain items listed here for CBAR, CBEAM elements using PBAR, PBEAM, PBARL, or
PBEAML properties include only normal stress/strain.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

815

DRESP1 - Static Stress Item Codes for Bar Elements using


PBARL, PBEAML Properties
The evaluation stresses (normal, shear, and von Mises) for each bar element are listed in the
links provided below. The shear stress includes torsion and shear.
Bar Element Types
BAR element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S1N
S2N
S3N
S4N

816

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SNMAX

S8S

S8V

SSMAX

SVMAX

BOX element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S1N

S1S

S1V

S2N

S2S

S2V

S3N

S3S

S3V

S4N

S4S

S4V

S5S

S5V

S6S

S6V

S7S

S7V

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

817

Normal Stress

SNMAX

Shear Stress

von Mises Stress

S8S

S8V

S9S

S9V

S10S

S10V

S11S

S11V

S12S

S12V

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
BOX1 element type

C ross-sectional dimensions and stress constraint evaluation points

818

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S1N

S1S

S1V

S2N

S2S

S2V

S3N

S3S

S3V

S4N

S4S

S4V

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

S10S

S10V

S11S

S11V

S12S

S12V

SSMAX

SVMAX

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
CHAN element type

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

819

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number

820

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

refers to stress recovered in the xz plane.


CHAN1 element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress Shear Stress

von Mises Stress

S1N
S2N
S3N
S4N

SNMAX

Altair Engineering

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

SSMAX

SVMAX

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

821

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
CHAN2 element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

S1N
S2N
S3N
S4N

822

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SNMAX

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
CROSS element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S1N

S1V

S2N

S2V

S3N

S3V

S4N

S4V

Altair Engineering

S5S

S5V

S6S

S6V

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

823

SNMAX

S7S

S7V

S8S

S8V

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
H element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S1N
S2N
S3N
S4N

824

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SNMAX

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
HAT element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S1N
S2N
S3N
S4N

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

825

SNMAX

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

S10S

S10V

S11S

S11V

S12S

S12V

S13S

S13V

S14S

S14V

S15S

S15V

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
I element type

826

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

827

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
I1 element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

S1N
S2N
S3N
S4N

828

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SNMAX

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
L element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S1N
S2N
S3N
S4N

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

829

SNMAX

SSMAX

SVMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
ROD element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

S1N

S1S

S2N

S2S

S3N

S3S

S4N

S4S

von Mises Stress

S5V
The location of point 5 will be determined by varying the
the maximum von Mises stress.

830

from 0 to 360 degrees to find

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

T element type

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
T1 element type

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

831

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
T2 element type

832

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these
cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.
TUBE element type

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

833

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

S1N

S1S

S2N

S2S

S3N

S3S

S4N

S4S

von Mises Stress

S5V
The location of point 5 will be determined by varying the
the maximum von Mises stress.

from 0 to 360 degrees to find

Z element type

834

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C ross-sectional dimensions and stress constraint evaluation points

Evaluation Stresses
Normal Stress

Shear Stress

von Mises Stress

S5S

S5V

S6S

S6V

S7S

S7V

S8S

S8V

S9S

S9V

SSMAX

SVMAX

S1N
S2N
S3N
S4N

SNMAX

Several stress recovery points are coincident (for example, 1 and 5, 2 and 6). In these

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

835

cases, the lower number refers to stress recovered in the xy plane and the higher number
refers to stress recovered in the xz plane.

836

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - Frequency Response Force Item Codes


Element

Response

Component ASCII code Number code*

CELAS

Force

Real

R-F

Imaginary

I-F

Magnitude

M-F

Phase

P-F

Real

R-FA

Imaginary

I-FA

Magnitude

M-FA

Phase

P-FA

Real

R-FA

Imaginary

I-FA

Magnitude

M-FA

Phase

P-FA

Real

R-FB

Imaginary

I-FB

Magnitude

M-FB

Phase

P-FB

Real

R-FA

Imaginary

I-FA

CDAMP

CVISC

Force

Axial force

Torque

CROD

Force at end A

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

837

Force at end B

CBAR/
CBEAM

Bending at end A
plane 1

Bending at end A
plane 2

Bending at end B
plane 1

Bending at end B
plane 2

838

Magnitude

M-FA

Phase

P-FA

Real

R-FB

Imaginary

I-FB

Magnitude

M-FB

Phase

P-FB

Real

R-MA1

Imaginary

I-MA1

10

Magnitude

M-MA1

Phase

P-MA1

10

Real

R-MA2

Imaginary

I-MA2

11

Magnitude

M-MA2

Phase

P-MA2

11

Real

R-MB1

Imaginary

I-MB1

12

Magnitude

M-MB1

Phase

P-MB1

12

Real

R-MB2

Imaginary

I-MB2

13

Magnitude

M-MB2

Phase

P-MB2

13

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Shear at end A
plane 1

Shear at end A
plane 2

Real

R-SA1

Imaginary

I-SA1

14

Magnitude

M-SA1

Phase

P-SA1

14

Real

R-SA2

Imaginary

I-SA2

15

Magnitude

M-SA2

Phase

P-SA2

15

R-FA

Imaginary

I-FA

16

Magnitude

M-FA

Phase

P-FA

16

Real

R-TA

Imaginary

I-TA

17

Magnitude

M-TA

Phase

P-TA

17

Real

R-SB1

Imaginary

I-SB1

Magnitude

M-SB1

Phase

P-SB1

Real

R-SB2

Imaginary

I-SB2

Axial force at end A Real

Torque at end A

Shear at end B
plane 1

Shear at end B
plane 2

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

839

Magnitude

M-SB2

Phase

P-SB2

Axial force at end B Real

Torque at end B

CBUSH

Force X

Force Y

Force Z

840

R-FB

Imaginary

I-FB

Magnitude

M-FB

Phase

P-FB

Real

R-TB

Imaginary

I-TB

Magnitude

M-TB

Phase

P-TB

Real

R-FX

Imaginary

I-FX

Magnitude

M-FX

Phase

P-FX

Real

R-FY

Imaginary

I-FY

Magnitude

M-FY

Phase

P-FY

Real

R-FZ

Imaginary

I-FZ

10

Magnitude

M-FZ

Phase

P-FZ

10

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Moment X

Moment Y

Moment Z

CSHEAR

Force 4 to 1

Force 2 to 1

Force 1 to 2

Altair Engineering

Real

R-MX

Imaginary

I-MX

11

Magnitude

M-MX

Phase

P-MX

11

Real

R-MY

Imaginary

I-MY

12

Magnitude

M-MY

Phase

P-MY

12

Real

R-MZ

Imaginary

I-MZ

13

Magnitude

M-MZ

Phase

P-MZ

13

Real

R-F41

Imaginary

I-F41

10

Magnitude

M-F41

Phase

P-F41

10

Real

R-F21

Imaginary

I-F21

11

Magnitude

M-F21

Phase

R-F21

11

Real

R-F12

Imaginary

I-F12

12

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

841

Force 3 to 2

Force 2 to 3

Force 4 to 3

Force 3 to 4

Force 1 to 4

Kick Force on 1

842

Magnitude

M-F12

Phase

P-F12

12

Real

I-F32

Imaginary

I-F32

13

Magnitude

M-F32

Phase

P-F32

13

Real

R-F23

Imaginary

I-F23

14

Magnitude

M-F23

Phase

P-F23

14

Real

R-F43

Imaginary

I-F43

15

Magnitude

M-F43

Phase

P-F43

15

Real

R-F34

Imaginary

I-F34

16

Magnitude

M-F34

Phase

P-F34

16

Real

R-F14

Imaginary

I-F14

17

Magnitude

M-F14

Phase

P-F14

17

Real

R-KF1

18

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Shear Flow 12

Kick Force on 2

All Shell
Elements

Membrane force X

Membrane force Y

Membrane shear
force XY

Altair Engineering

Imaginary

I-KF1

26

Magnitude

M-KF1

18

Phase

P-KF1

26

Real

R-SH12

19

Imaginary

I-SH12

27

Magnitude

M-SH12

19

Phase

P-SH12

27

Real

R-KF2

20

Imaginary

I-KF2

28

Magnitude

M-KF2

20

Phase

P-KF2

28

Real

R-NX

Imaginary

I-NX

10

Magnitude

M-NX

Phase

P-NX

10

Real

R-NY

Imaginary

I-NY

11

Magnitude

M-NY

Phase

P-NY

11

Real

R-NXY

Imaginary

I-NXY

12

Magnitude

M-NXY

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

843

Phase

P-NXY

12

R-MX

Imaginary

I-MX

13

Magnitude

M-MX

Phase

P-MX

13

R-MY

Imaginary

I-MY

14

Magnitude

M-MY

Phase

P-MY

14

Real

R-MXY

Imaginary

I-MXY

15

Magnitude

M-MXY

Phase

P-MXY

15

Real

R-SXZ

Imaginary

I-SXZ

16

Magnitude

M-SXZ

Phase

P-SXZ

16

Real

R-SYZ

Imaginary

I-SYZ

17

Magnitude

M-SYZ

Phase

P-SYZ

17

Bending Moment X Real

Bending Moment Y Real

Twisting moment
XY

Transverse shear
XZ

Transverse shear
YZ

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

844

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - Frequency Response Stress/Strain Item Codes


Element

Stress/Strain
Item

Component

ASCII code Number code*

CELAS

Stress/Strain

Real

R-S

Imaginary

I-S

Magnitude

M-S

Phase

P-S

Real

R-SAB

Imaginary

I-SAB

Magnitude

M-SAB

Phase

P-SAB

Real

R-SA

Imaginary

I-SA

Magnitude

M-SA

Phase

P-SA

Real

R-SB

Imaginary

I-SB

Magnitude

M-SB

Phase

P-SB

Real

R-SALL

Imaginary

I-SALL

Magnitude

M-SALL

Phase

P-SALL

CROD

Both ends

End A

End B

CBAR

All Stresses/
Strains

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

845

Element

Stress/Strain
Item

Component

ASCII code Number code*

End A point C

Real

R-SAC

Imaginary

I-SAC

Magnitude

M-SAC

Phase

P-SAC

Real

R-SAD

Imaginary

I-SAD

Magnitude

M-SAD

Phase

P-SAD

Real

R-SAE

Imaginary

I-SAE

Magnitude

M-SAE

Phase

P-SAE

Real

R-SAF

Imaginary

I-SAF

10

Magnitude

M-SAF

Phase

P-SAF

10

Real

R-SBC

12

Imaginary

I-SBC

16

Magnitude

M-SBC

12

Phase

P-SBC

16

Real

R-SBD

13

End A point D

End A point E

End A point F

End B point C

End B point D

846

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Element

Stress/Strain
Item

End B point E

End B point F

Maximum at end
A

Maximum at end
B

CBEAM

All Stresses/
Strains

Altair Engineering

Component

ASCII code Number code*

Imaginary

I-SBD

17

Magnitude

M-SBD

13

Phase

P-SBD

17

Real

R-SBE

14

Imaginary

I-SBE

18

Magnitude

M-SBE

14

Phase

P-SBE

18

Real

R-SBF

15

Imaginary

I-SBF

19

Magnitude

M-SBF

15

Phase

P-SBF

19

Real

R-SAMAX

Imaginary

I-SAMAX

Magnitude

M-SAMAX

Phase

P-SAMAX

Real

R-SBMAX

Imaginary

I-SBMAS

Magnitude

M-SBMAX

Phase

P-SBMAX

Real

R-SALL

Imaginary

I-SALL

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

847

Element

Stress/Strain
Item

End A point C

End A point D

End A point E

End A point F

End B point C

848

Component

ASCII code Number code*

Magnitude

M-SALL

Phase

P-SALL

Real

R-SAC

Imaginary

I-SAC

Magnitude

M-SAC

Phase

P-SAC

Real

R-SAD

Imaginary

I-SAD

Magnitude

M-SAD

Phase

P-SAD

Real

R-SAE

Imaginary

I-SAE

10

Magnitude

M-SAE

Phase

P-SAE

10

Real

R-SAF

Imaginary

I-SAF

11

Magnitude

M-SAF

Phase

P-SAF

11

Real

R-SBC

104

Imaginary

I-SBC

108

Magnitude

M-SBC

104

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Element

Stress/Strain
Item

End B point D

End B point E

End B point F

Maximum at end
A

Maximum at end
B

Altair Engineering

Component

ASCII code Number code*

Phase

P-SBC

108

Real

R-SBD

105

Imaginary

I-SBD

109

Magnitude

M-SBD

105

Phase

P-SBD

109

Real

R-SBE

106

Imaginary

I-SBE

110

Magnitude

M-SBE

106

Phase

P-SBE

110

Real

R-SBF

107

Imaginary

I-SBF

111

Magnitude

M-SBF

107

Phase

P-SBF

111

Real

R-SAMAX

Imaginary

I-SAMAX

Magnitude

M-SAMAX

Phase

P-SAMAX

Real

R-SBMAX

Imaginary

I-SBMAX

Magnitude

M-SBMAX

Phase

P-SBMAX

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

849

Element

Stress/Strain
Item

Component

ASCII code Number code*

CSHEAR

Maximum Shear

Real

R-SHMAX

Imaginary

I-SHMAX

Magnitude

M-SHMAX

Phase

P-SHMAX

Real

R-SHAVG

Imaginary

I-SHAVG

Magnitude

M-SHAVG

Phase

P-SHAVG

Real

R-SXX

Imaginary

I-SXX

12

Magnitude

M-SXX

Phase

P-SXX

12

Real

R-SYY

Imaginary

I-SYY

13

Magnitude

M-SYY

Phase

P-SYY

13

Real

R-SZZ

Imaginary

I-SZZ

14

Magnitude

M-SZZ

Phase

P-SZZ

14

Average Shear

All Solid
Elements

Normal X

Normal Y

Normal Z

850

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Element

Stress/Strain
Item

Component

ASCII code Number code*

Shear XY

Real

R-SXY

Imaginary

I-SXY

15

Magnitude

M-SXY

Phase

P-SXY

15

Real

R-SYZ

10

Imaginary

I-SYZ

16

Magnitude

M-SYZ

10

Phase

P-SYZ

16

Real

R-SXZ

11

Imaginary

I-SXZ

17

Magnitude

M-SXZ

11

Phase

P-SXZ

17

SVM

Shear YZ

Shear XZ

von Mises
All Shell
Elements

Normal X at both Real


surfaces
Imaginary

Normal X at Z1

Altair Engineering

R-SXB
I-SXB

Magnitude

M-SXB

Phase

P-SXB

Real

R-SX1

Imaginary

I-SX1

Magnitude

M-SX1

Phase

P-SX1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

851

Element

Stress/Strain
Item

Component

ASCII code Number code*

Normal X at Z2

Real

R-SX2

10

Imaginary

I-SX2

11

Magnitude

M-SX2

10

Phase

P-SX2

11

Normal Y at both Real


surfaces
Imaginary

Normal Y at Z1

Normal Y at Z2

852

I-SYB

Magnitude

M-SYB

Phase

P-SYB

Real

R-SY1

Imaginary

I-SY1

Magnitude

M-SY1

Phase

P-SY1

Real

R-SY2

12

Imaginary

I-SY2

13

Magnitude

M-SY2

12

Phase

P-SY2

13

Shear XY at both Real


surfaces
Imaginary

Shear XY at Z1

R-SYB

R-SXYB
I-SXYB

Magnitude

M-SXYB

Phase

P-SXYB

Real

R-SXY1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Element

Stress/Strain
Item

Component

ASCII code Number code*

Imaginary

I-SXY1

Magnitude

M-SXY1

Phase

P-SXY1

Real

R-SXY2

14

Imaginary

I-SXY2

15

Magnitude

M-SXY2

14

Phase

P-SXY2

15

von Mises at Z1

SVM1

von Mises at Z2

SVM2

von Mises

SVMB

Shear XY at Z2

* OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

853

DRESP1 - Frequency Response Displacement, Velocity,


and Acceleration Item Codes
Response

Component

ASCII code Number code*

Translation X

Real

R-TX

Imaginary

I-TX

Magnitude

M-TX

Phase

P-TX

Real

R-TY

Imaginary

I-TY

Magnitude

M-TY

Phase

P-TY

Real

R-TZ

Imaginary

I-TZ

Magnitude

M-TZ

Phase

P-TZ

Real

R-RX

Imaginary

I-RX

10

Magnitude

M-RX

Phase

P-RX

10

Real

R-RY

Imaginary

I-RY

11

Magnitude

M-RY

Phase

P-RY

11

Translation Y

Translation Z

Rotation X

Rotation Y

854

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Response

Component

ASCII code Number code*

Rotation Z

Real

R-RZ

Imaginary

I-RZ

12

Magnitude

M-RZ

Phase

P-RZ

12

Real

R-NORM

Imaginary

I-NORM

Magnitude

M-NORM

Phase

P-NORM

Normal

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

855

DRESP1 - Frequency Response Pressure Item Codes


Response

Component

ASCII code Number code*

Pressure

Real

R-PRES

Imaginary

I-PRES

Magnitude

M-PRES

Phase

P-PRES

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

856

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - Center of Gravity and Moments of Inertia Item


Codes
Center of Gravity
Component

ASCII Code

x-coordinate

y-coordinate

z-coordinate

Moments of Inertia
Component

ASCII Code

lxx

XX

lyy

YY

lzz

ZZ

lxy

XY

lxz

XZ

lyz

YZ

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

857

DRESP1 - Static Force Item Codes


Element

Force Item

ASCII Code

Number Code *

CELAS

Force

CROD

Force End A

FA

Force End B

FB

Bending End A Plane 1

MA1

Bending End A Plane 2

MA2

Bending End B Plane 1

MB1

Bending End B Plane 2

MB2

Shear End A Plane 1

SA1

Shear End A Plane 2

SA2

Axial Force End A

FA

Torque End A

TA

Shear End B Plane 1

SB1

Shear End B Plane 2

SB2

Axial Force End B

FB

Torque End B

TB

Bending End A Plane 1

MA1

Bending End A Plane 2

MA2

Bending End B Plane 1

MB1

94

Bending End B Plane 2

MB2

95

CBAR

CBEAM

858

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Element

CBUSH

All Shell
Elements

Altair Engineering

Force Item

ASCII Code

Number Code *

Shear End A Plane 1

SA1

Shear End A Plane 2

SA2

Axial Force End A

FA

Torque End A

TA

Shear End B Plane 1

SB1

96

Shear End B Plane 2

SB2

97

Axial Force End B

FB

98

Torque End B

TB

99

Force-X

FX

Force-Y

FY

Force-Z

FZ

Moment-X

MX

Moment-Y

MY

Moment-Z

MZ

Membrane Force X

NX

Membrane Force Y

NY

Membrane Shear Force XY

NXY

Bending Moment X

MX

Bending Moment Y

MY

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

859

Element

CSHEAR

Force Item

ASCII Code

Number Code *

Twisting Moment XY

MXY

Transverse Shear XZ

SXZ

Transverse Shear YZ

SYZ

Force 4 to 1

F41

Force 2 to 1

F21

Force 1 to 2

F12

Force 3 to 2

F32

Force 2 to 3

F23

Force 4 to 3

F43

Force 3 to 4

F34

Force 1 to 4

F14

Kick Force on 1

KF1

10

Shear Flow 12

SH12

11

Kick Force on 2

KF2

12

Shear Flow 23

SH23

13

Kick Force on 3

KF3

14

Shear Flow 34

SH34

15

Kick Force on 4

KF4

16

Shear Flow 41

SH41

17

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items

860

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

861

DRESP1 - Static Failure Item Codes for Composites


Theory

ASCII code

Hill

HILL

Hoffman

HOFF

Tsai-Wu

TSAI

Maximum Strain

STRN

862

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - Static Stress/Strain Item Codes for Composites

Stress Item

ASCII Code

Number code*

Normal - 1

S1

Normal - 2

S2

Shear - 12

S12

Shear - 1Z

S1Z

Shear - 2Z

S2Z

Maj. Principal

SMAP

Min. Principal

SMIP

10

OptiStruct provides partial support for Nastran item codes. Since Nastran response
items are not fully compatible with those used in OptiStruct, it is recommended to use
the OptiStruct ASCII item codes.

Strain Item

ASCII Code

Number Code*

Normal - 1

S1

Normal - 2

S2

Shear - 12

S12

Maj. Principal

SMAP

Min. Principal

SMIP

10

OptiStruct provides partial support for Nastran item codes. Since Nastran response
items are not fully compatible with those used in OptiStruct, it is recommended to use
the OptiStruct ASCII item codes.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

863

Thermal Strain Item

ASCII Code

Number Code*

Normal - 1

TS1

Normal - 2

TS2

Shear - 12

TS12

Maj. Principal

TSMAP

Min. Principal

TSMIP

OptiStruct provides partial support for Nastran item codes. Since Nastran response
items are not fully compatible with those used in OptiStruct, it is recommended to use
the OptiStruct ASCII item codes.

Mechanical Strain Item

ASCII Code

Number Code*

Normal - 1

MS1

Normal - 2

MS2

Shear - 12

MS12

Maj. Principal

MSMAP

Min. Principal

MSMIP

864

OptiStruct provides partial support for Nastran item codes. Since Nastran response
items are not fully compatible with those used in OptiStruct, it is recommended to use
the OptiStruct ASCII item codes.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - MBD Displacement Item Codes


Displacement

ASCII code

Translational X

TX

Translational Y

TY

Translational Z

TZ

Rotational X

RX

Rotational Y

RY

Rotational Z

RZ

Translational
resultant

TXYZ

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

865

DRESP1 - MBD Velocity/Acceleration Item Codes


Vel/Acc

ASCII code

Translational X

TX

Translational Y

TY

Translational Z

TZ

Rotational X

RX

Rotational Y

RY

Rotational Z

RZ

Translational
resultant

TXYZ

Rotational
resultant

RXYZ

866

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 - MBD Force Item Codes


Force

ASCII code

Translational X

FX

Translational Y

FY

Translational Z

FZ

Rotational X

MX

Rotational Y

MY

Rotational Z

MZ

Translational
resultant

FXYZ

Rotational
resultant

MXYZ

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

867

DRESP1 PSD/RMS Displacement, Velocity, and


Acceleration Item Codes
Response

ASCII code Number code*

Translation X

TX

Translation Y

TY

Translation Z

TZ

Rotation X

RX

Rotation Y

RY

Rotation Z

RZ

*OptiStruct provides partial support for Nastran item codes. Since Nastran response items
are not fully compatible with those used in OptiStruct, it is recommended that the OptiStruct
ASCII item codes be used.

868

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP1 PSD/RMS Pressure Item Codes


Response

ASCII code

Pressure

PRES

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

869

DRESP1 - PSD/RMS Stress/Strain Item Codes


All Solid elements

All Shell elements

870

Stress/Strain Item

ASCII code

Normal X

SXX

Normal Y

SYY

Normal Z

SZZ

Shear XY

SXY

Shear YZ

SYZ

Shear XZ

SXZ

Stress/Strain Item

ASCII code

Normal X both surfaces

SXB

Normal X 1

SX1

Normal X 2

SX2

Normal Y both surfaces

SYB

Normal Y 1

SY1

Normal Y 2

SY2

Shear XY both surfaces

SXYB

Shear XY 1

SXY1

Shear XY 2

SXY2

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP2
Bulk Data Entry
DRESP2 Design Response via Equations for Design Optimization
Description
When a desired response is not directly available from OptiStruct, it may be calculated using
DRESP2. This response can be a functional combination of any set of responses resulting from
the design analysis iteration. Responses defined in this manner can be used as design
objectives or constraints. The DRESP2 card identifies the equation to use for the response
relationship and the input values to evaluate the response function.
Format
(1)

(2)

(3)

(4)

(5)

DRESP2

ID

LABEL

EQID
or
FUNC

REGION

DRESPM

RID1

MODEL
NAME1

VARTYPE1

ID1

VARTYPE2

...

(6)

(7)

(8)

(9)

RID2

MODEL
NAME2

...

...

ID2

ID3

ID4

ID5

ID6

ID7

ID8

...

...

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

...

...

...

...

...

...

...

...

...

(10)

Example 1

Define a response labeled FUNC1 that references equation #999, where DESVAR #11 is the
first variable, the DTABLE entry PI is the second variable, DRESP1 #1 is the third variable,
the Y location of grid #11 is the forth variable and the DVPREL1 #22 is the fifth variable.

(1)

(2)

Altair Engineering

(3)

(4)

(5)

(6)

(7)

(8)

(9)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

871

DRESP2

10

FUNC 1

DESVAR

11

DTABLE

PI

DRESP1

DGRID

11

DVPREL1

22

999

Example 2

Define a response that is the weighted average of 2 displacements


(1)

(2)

(3)

(4)

(5)

DRESP2

AVDIS

DRESP1

(6)

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DRESP1

TOPN

DISP

4668

DRESP1

BOTN

DISP

5432

(10)

DEQATN

Field

Contents

ID

Response identification number. Each DRESP2 card must have a unique

872

y(x1, x2) = (x1*1.5+ x2*4.0)/2

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
ID with respect to all other DRESP# cards.
No default (Integer > 0)

LABEL

User defined name for the response.


No default (Character)

EQID

DEQATN identifier that defines the response relationship.


No default (Integer > 0)

FUNC

Function to be applied to the arguments (see comment 14).


No default (Character)

REGION

Region identifier (see comment 4).


Default = blank (Integer > 0 or blank)

DRESPM

Indicates the beginning of a continuation line, which defines modelspecific response ID and Model Name pairs to be used in a Multi-Model
Optimization run.

RID#

Identification numbers of model-specific responses (see comment 15).

MODEL
NAME#

User-defined model names defined on the ASSIGN, MMO entry (see


comment 15).

VARTYPE# Indicates the type of variables to follow. Can be one of: DESVAR,
DTABLE, DGRID, DGRIDB, DRESP1, DRESP1L, DRESP2, DRESP2L, DVPREL1,
DVPREL2, DVCREL1, DVCREL2, DVMREL1, DVMREL2, DVMBRL1, or
DVMBRL2 (see comments 5, 13 and 16).
No default (Character)
ID#

When VARTYPE is DESVAR, DTABLE, DRESP1, DRESP2, DVPREL1,


DVPREL2, DVCREL1, DVCREL2, DVMREL1, DVMREL2, DVMBRL1, or
DVMBRL2 this list of IDs reference entities of the defined VARTYPE.
When VARTYPE is DGRID or DGRIDB, the list is a list of GRID/ID
Component pairs, where every second value is a component (1, 2, or 3).
For example, DGRID, 11, 2 indicates the Y component of grid 11 (see

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

873

Field

Contents
comment 13).
When VARTYPE is DRESP1L or DRESP2L, the list is a list of response/
subcase pairs, where every second value is a subcase ID, for example,
DRESP1L, 9, 1, 9, 3 indicates response 9 calculated for subcase 1 and
response 9 calculated for subcase 3.
No default (Integer > 0)

Comments
1.

DRESP2 entries are referenced from the subcase through one of DESOBJ, DESSUB, or
DESGBL.

2.

DRESP2 entries must have unique identification numbers with respect to DRESP1 and
DRESP3 entries.

3.

DRESP1L, DRESP2L define a response defined with a DRESP1 or DRESP2, respectively, and
a SUBCASE. The SUBCASE number 0 should be used for global responses.

4.

Responses with the same region identifier are grouped together into the same region. If
the region identifier is blank, then a separate region is formed for each DRESP2 definition.
The RTYPE EQUA on the DSCREEN definition refers to DRESP2 responses. It is important
to ensure that responses with the same region identifier reference similar equations. For
further information, refer to Constraint Screening in the User's Guide.

5.

Any number of VARTYPE# continuation lines can be defined. The order in which the
VARTYPE# continuation lines are listed on the DRESP2 card is not prescribed. The same
VARTYPE# can be repeated any number of times, in any position, on the card. However,
the order in which the VARTYPE# continuation lines are listed will affect the solution as
the values are passed to the equation (or function) in the listed sequence.

6.

The entries on the DRESP2 cards are assigned to the variable on the DEQATN card in the
order that they occur. For example 2 above x1 is the displacement response defined by
the DRESP1 card with ID=9 and x2 is the displacement response defined by the DRESP1
card with ID=2.

7.

DRESPi and DRESPiL cards cannot be mixed on the same DRESP2 definition.

8.

If DRESP1L, DRESP2L are used for a constrained DRESP2, DESGLB must be used to identify
the DRESP2.

9.

If DRESP1L, DRESP2L are used in a DRESP2 objective function, then the DESOBJ that
references the DRESP2 must be defined before the first Subcase.

10. If the DRESP2 data is referenced by DESOBJ data, the DESOBJ data must be above the
first SUBCASE if:
The DRESP2 contains DRESP1L, DRESP2L data.
The DRESP2 contains no DRESP1DRESP2, DRESP1L, or DRESP2L data.

874

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

The DRESP2 contains DRESP1, DRESP2 global responses.


The DESOBJ data must be in the correct SUBCASE if the DRESP2 contains subcase
dependent DRESP1 responses.
11. LABEL must begin with an alphabetical character.
12. DRESP2 cannot reference itself directly or recursively, but multiple levels of referencing
are allowed.
13. The DGRID and DGRIDB VARTYPEs can be used to select grid point locations as variables
to be passed to the specified equation or function. The grid point locations are specified
as a list of Grid point ID/Component pairs where every second value is a component. The
Grid point IDs are unique grid point identification numbers (ID) and Components are the
grid point locations X1, X2, and X3 fields on the GRID bulk data entry.
Examples:

DGRIDB:
The VARTYPE DGRIDB can be used to select grid point locations in the basic coordinate
system. The basic coordinate system is the default rectangular coordinate system in
OptiStruct.
DGRID:
The VARTYPE DGRID can be used to select the grid point locations in the local coordinate
system of each grid point. This local coordinate system may be specified by the CP field
of the GRID bulk data entry for a particular grid point of interest. All local (or user defined)
coordinate systems are directly or indirectly based on the default basic coordinate
system.
14. The following functions can be used instead of an EQID. If FUNC is used, the DEQATN
entry is no longer needed. The functions are applied to all arguments on the DRESP2
regardless of their type.
Function

Description

SUM

Sum of arguments

AVG

Average of arguments

Altair Engineering

Formula

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

875

Function

Description

Formula

SSQ

Sum of square of arguments

RSS

Square root of sum of squares of


arguments

MAX

Maximum of arguments

MIN

Minimum of arguments

SUMABS

Sum of absolute value of arguments

AVGABS

Average of absolute value of


arguments

MAXABS

Maximum of absolute arguments

MINABS

Minimum of absolute value of


arguments

15. Multiple RID-Model Name pairs can be specified on a single DRESPM continuation line.
These responses can be used similar to responses defined via the VARTYPE# -ID# entries.
ASSIGN, MMO can be used to identify the filename of the model and the user-defined
Model Name that contains the referenced response definition.
16. An inconsistent number of responses can be referenced via multiple DRESP#L VARTYPEs.
The following requirements should be met for such entries:
1. A minimum of one DRESP# entry listed on a corresponding DRESP#L VARTYPE should
reference only a single response value, (and)
2. DRESP# entries listed on other DRESP#L VARTYPEs should reference the same number
of responses.
3. If requirement (1) above is not met, then the number of responses referenced by all
the DRESP# entries (listed on all the DRESP#L VARTYPEs) should be equal.
Example
Allowed
DRESP1
2
DRESP1

876

R1

STRESS

ELEM

SVM3

R2

STRESS

PSHELL

SVM4

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DRESP2
+
+
DRESP1
DEQATN

3
MA
1
DRESP1L
4
0
DRESP1L
2
2
4
vol
VOLUME
1
f(a,b)=a+b

Not Allowed
DRESP1
2
DRESP1
DRESP2
+
+
+
DRESP1
DEQATN

R1

STRESS

ELEM

2
R2
STRESS PSHELL
3
MNA
1
DRESP1L
4
0
DRESP1L
1
2
DRESP1L
2
2
4
vol
VOLUME
1
f(a,b,c)=a+b+c

SVM1

SVM2

In the above example (Allowed), the number of responses referenced by DRESP1L=4 is


one. Also, DRESP1L=2 references multiple responses, this is allowed as there are no other
DRESP#L that reference more than one response. However, in the Not Allowed example,
DRESP1L=1 references two responses and DRESP1L=2 references multiple responses (this
violates requirement 2 above).
17. This card is represented as optimization responses in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

877

DRESP3
Bulk Data Entry
DRESP3 Design Response via External User-supplied Functions
Description
When a desired response is not available from OptiStruct, either directly or via equations, it
may be calculated through external user-supplied functions implemented in shared/dynamic
libraries or external files (see External Reponses). The DRESP3 card identifies the external
function to be called and defines the parameters to be transferred to that function.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DRESP3

ID

LABEL

GROUP

FUNC

REGION

RESP

MAXRESP

DRESPM

RID1

MODEL
NAME1

RID2

MODEL
NAME2

...

...

VARTYPE1

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

...

...

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

...

...

ID1

ID2

ID3

ID4

ID5

ID6

ID7

C I2

C I3

...

C In

VARTYPE2

(9)

(10)

...

VARTYPEn

ID8

878

C ELLIN

C I1

C ELLOUT

CO

SENSOPT

METHOD

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Alternate format for CELLIN (cell input) specifications


C ELLIN

C I1

thru

C In

Alternate format when VARTYPE is DEIGV


DEIGV

EIGV1

LID1

G1

C1

EIGV2

LID2

G2

C2

...

...

...

...

Alternate format when VARTYPE is USRDATA


USRDATA

STRNG

...

Field

Contents

ID

Response identification number. Each DRESP3 must have a unique ID with


respect to all other DRESP# cards.
No default (Integer > 0)

LABEL

User-defined name for the response.


No default (Character)

GROUP

GROUP identifier that defines the shared/dynamic library or external


Microsoft Excel workbook to be used (see comment 19). It references an
existing LOADLIB entry in the input deck.
No default (Character)

FUNC

FUNC identifier that defines the external function to be used.


No default (Character)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

879

Field

Contents

REGION

Region identifier (see comment 4).


Default = blank (Integer > 0 or blank)

DRESPM

Indicates the beginning of a continuation line, which defines modelspecific response ID and Model Name pairs to be used in a Multi-Model
Optimization run.

RID#

Identification numbers of model-specific responses (see comment 21)

MODEL
NAME#

User-defined model names defined on the ASSIGN, MMO entry (see


comment 21).

RESP

RESP identifier that defines the response to be returned by the external


function.
No default (Integer > 0)

MAXRESP

MAXRESP identifier that defines the number of responses available in the


external function.
No default (Integer > 0)

VARTYPE#

Indicates the type of variables to follow. Can be one of: DESVAR,


DTABLE, DGRID, DGRIDB, DEIGV, DRESP1, DRESP1L, DRESP2, DRESP2L,
DVPREL1, DVPREL2, DVCREL1, DVCREL2, DVMREL1, DVMREL2, DVMBRL1,
DVMBRL2, USRDATA or SLAVE (see comment 18).
No default (Character)

ID#

When VARTYPE is DESVAR, DTABLE, DRESP1, DRESP2, DVPREL1, DVPREL2,


DVCREL1, DVCREL2, DVMREL1, DVMREL2, DVMBRL1, or DVMBRL2 this list of
IDs reference entities of the defined VARTYPE.
When VARTYPE is DGRID or DGRIDB, the list is a list of GRID/Component
pairs, where every second value is a component (1, 2, or 3). For example,
DGRID, 11, 2 indicates the Y component of grid 11.
When VARTYPE is DEIGV, the ID# list is replaced by a list of eigenvectors,
with each line defining an eigenvector ID, a subcase ID, and a grid/
component pair (where the component is one of 1, 2, 3, 4, 5 or 6).
When VARTYPE is DRESP1L or DRESP2L, the list is a list of response/
subcase pairs, where every second value is a subcase ID, for example,

880

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
DRESP1L, 9, 1, 9, 3 indicates response 9 calculated for subcase 1 and
response 9 calculated for subcase 3.
When VARTYPE is USRDATA, the list is replaced by a user-defined
character string, which is passed to the external function. This character
string must be less than 32000 characters.
When VARTYPE is SLAVE, only a single ID should follow. This is the ID of
another DRESP3 entry from which data should be copied.
No default (Integer > 0, or Character)

CELLIN

CELLIN flag indicates that a list of Microsoft Excel worksheet cell


references are to follow, that define response input values (see comments
19 and 20).

CI#

A list of Microsoft Excel worksheet cell references that define response


input values (see comments 19 and 20).
No default (Alphanumeric)

CELLOUT

CELLIN flag indicates that a Microsoft Excel Worksheet cell reference is to


follow that defines the response output value (see comments 19 and 20).

CO

A Microsoft Excel worksheet cell reference that defines the response


output value (see comments 19 and 20).
No default (Alphanumeric)

SENSOPT

Indicates that the sensitivities evaluation method follows.

METHOD

Method to be used for sensitivities evaluation (see comment 17).


NONE (or blank): Sensitivities are not provided. Full evaluations are
performed at every step of the approximation process.
AUTO: Sensitivities are automatically evaluated by finite differences at
the beginning of the iteration, and subsequently used in the approximation
process.
USER: Sensitivities are provided by the external function at the beginning
of the iteration, and subsequently used in the approximation process.
Default = NONE (or blank)

EIGVi

Eigenvector numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

881

Field

Contents
No default (Integer > 0)

LIDi

Subcase IDs.
No default (Integer > 0)

Gi

Grid IDs.
No default (Integer > 0)

Ci

Component IDs.
No default (1, 2, 3, 4, 5, or 6)

STRNG

User-defined string to be passed to the external function.


No default (Character string < 32000 characters)

Comments
1.

DRESP3 entries are referenced from the subcases through one of DESOBJ, DESSUB, or
DESGBL.

2.

DRESP3 entries must have unique identification numbers with respect to DRESP2 and
DRESP1 entries.

3.

DRESP1L, DRESP2L define a response defined with a DRESP1 or DRESP2, respectively, and
a SUBCASE. The SUBCASE number 0 should be used for global responses.

4.

Responses with the same region identifier are grouped together into the same region. If
the region identifier is blank, then a separate region is formed for each DRESP3 definition.
The RTYPE EXTERNAL on the DSCREEN definition refers to DRESP3 responses. It is
important to ensure that responses with the same region identifier reference similar
external responses. For further information, refer to Constraint Screening in the User's
Guide.

5.

Any number of VARTYPE# continuation lines can be defined. The order in which the
VARTYPE# continuation lines are listed on the DRESP2 card is not prescribed. The same
VARTYPE# can be repeated any number of times, in any position, on the card.

6.

The entries on the DRESP3 card are assigned to the parameters passed to the external
function in the order that they occur.

7.

DRESPi and DRESPiL cards cannot be mixed on one DRESP3 definition.

8.

If DRESP1L, DRESP2L is used for a constrained DRESP3, DESGLB must be used to identify
the DRESP3.

882

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

9.

If DRESP1L, DRESP2L is used in a DRESP3 objective function, then the DESOBJ that
references the DRESP3 must be defined before the first subcase.

10. If the DRESP3 data is referenced by DESOBJ data, the DESOBJ data must be above the
first SUBCASE if:
DRESP3 contains DRESP1L, DRESP2L data.
DRESP3 contains no DRESP1, DRESP2 or DRESP1L, DRESP2L data.
DRESP3 contains DRESP1, DRESP2 global responses.
The DESOBJ data must be in the correct static or eigenvalue SUBCASE if the DRESP3
contains static or eigenvalue DRESP1 responses.
11. DRESP1 of RTYPE = WCOMB, WFREQ, and COMP cannot be referenced by DRESP3 data.
12. LABEL must begin with an alphabetical character.
13. The RESP field may be used to request a specific response from the external function,
while MAXRESP defines the maximum number of responses available in that function.
External functions can be implemented to compute any number of responses and to return
any subset of these responses. This approach has two main benefits:
There is no need to write a specific external function for each response that you want
computed. One general function may be written instead. In many cases, this allows
for easier code maintenance and better code reusability.
OptiStruct will automatically group responses which point to the same external
function, and which use the same set of input data. The external function will only be
called once for that group of responses, which may save computational time in the
library.
14. The SLAVE continuation line indicates that the input data (DESVAR, and so on) for the
current DRESP3 card is identical to the input data of the master DRESP3 card. There
cannot be any other continuation line when SLAVE is used.
This simplifies the DRESP3 definition and reduces potential errors when modifying input
decks, either via the HyperMesh interface or manually. Also, as explained above,
OptiStruct will group responses that share the same input data.
15. The data in the STRNG field is character string based. It provides a convenient way to
pass constants to the external response server routines. The maximum number of
characters allowed in 32000.
16. The eigenvector values provided on the DEIGV continuation are normalized against the
mass matrix. No sensitivities are calculated for these values.
17. Performance of the sensitivity evaluation method is problem dependent, and selection of a
method depends on the number of arguments and the cost of each evaluation. The
default method works best for most problems. However, if the approximation module is
observed to be very slow with the default, AUTO or USER can be tried.
USER: This setup is more complex as it requires user-calculated gradients. However,
since finite differences are not used, it can improve the quality of those gradients and
may also increase the speed at which those gradients are calculated.
18. The DGRID and DGRIDB VARTYPEs can be used to select grid point locations as variables

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

883

to be passed to the specified equation or function. The grid point locations are specified
as a list of Grid point ID/Component pairs where every second value is a component. The
Grid point IDs are unique grid point identification numbers (ID) and Components are the
grid point locations X1, X2, and X3 fields on the GRID Bulk Data Entries.
Examples:

DGRIDB:
The VARTYPE DGRIDB can be used to select grid point locations in the basic coordinate
system. The basic coordinate system is the default rectangular coordinate system in
OptiStruct.
DGRID:
The VARTYPE DGRID can be used to select the grid point locations in the local coordinate
system of each grid point. This local coordinate system may be specified by the CP field
of the GRID Bulk Data Entry for a particular grid point of interest. All local (or user
defined) coordinate systems are directly or indirectly based on the default basic
coordinate system.
19. An external Microsoft Excel workbook can be referenced on the GROUP field via the
LOADLIB I/O Options Entry.
20. Multiple CELLIN continuation lines can be specified; each CI# entry on the CELLIN
continuation lines corresponds to responses (ID#) defined on the VARTYPE# continuation
lines. See External Responses in the Users Guide for further information.
21. Multiple RID-Model Name pairs can be specified on a single DRESPM continuation line.
These responses can be used similar to responses defined via the VARTYPE# -ID# entries.
ASSIGN, MMO can be used to identify the filename of the model and the user-defined
Model Name that contains the referenced response definition.

884

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DSCREEN
Bulk Data Entry
DSCREEN Design Constraint Screening
Description
Defines design constraint screening data. Refer to Constraint Screening in the User's Guide
section.
Format
(1)

(2)

(3)

(4)

DSC REEN

RTYPE

THOLD

MAXC

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(5)

(6)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

DSC REEN

AUTO

LEVEL

Example

(1)

(2)

(3)

(4)

DSC REEN

STRESS

-0.6

(5)

(6)

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

(7)

DRESP1

98

SS11

STRESS

PSHELL

DRESP1

99

SS11

STRESS

PSHELL

DRESP1

100

SS11

STRESS

PSHELL

Altair Engineering

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

885

Field

Contents

RTYPE

Response type affected by the constraint screening settings on this


definition.
No default (Character; See comment 1)

THOLD

Normalized threshold value constraint will not be retained during the


current iteration if its normalized value is below THOLD.
Default = -0.5 (Real < 0.0)

MAXC

Maximum number of constraints to be retained for each region definition and


each load case.
Default = 20 (Integer > 0)

AUTO

Automatic adjustment of screening criteria.


When this is activated, the screening algorithm will seek to retain the least
number of responses that are necessary for stable convergence.
Automatic constraint screening is active by default. It is disabled by the
presence of any DSCREEN definition in the input data.

LEVEL

The automatic constraint screening has levels 1 through 5, with 1 being the
least aggressive (more responses retained) and 5 being the most aggressive
(less responses retained). Level 3 is the default.
The automatic constraint screening can also be disabled by setting it to
OFF.
Default = 3 (1, 2, 3, 4, 5 or OFF)

Comments
1.

RTYPE may be any of the RTYPEs allowed on the DRESP1 entry, or EQUA or EXTERNAL or
AUTO.

2.

RTYPE EQUA refers to DRESP2 definitions. If DRESP2 definitions are given the same region
identifier, they should reference similar equations.

3.

RTYPE EXTERNAL refers to DRESP3 definitions. If DRESP3 definitions are given the same
region identifier, they should reference similar equations.

4.

F is the normalized constraint. If F> THOLD, then the constraint will be retained. F is
calculated with respect to the upper and lower bounds of the constraint as follows:

886

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

The THOLD and MAXC defaults do not apply for MASS, MASSFRAC, VOLUME,
VOLUMEFRAC, or FREQ. Constraint screening is not active for these responses by default.

6.

When no DSCREEN definitions are present in the input data, automatic constraint
screening is active for all responses. The presence of any DSCREEN definition disables
the automatic screening for all response types.

7.

With automatic screening, the upper bound on the EIGRL card for buckling analysis will be
adjusted in order to calculate only the necessary buckling eigenvalues (responses) that
are potentially retained in the optimization.

8.

This card is represented as an optidscreens in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

887

DSHAPE
Bulk Data Entry
DSHAPE Design Variable for Free-Shape Optimization
Description
Defines parameters for the generation of free-shape design variables.
Format
(1)

(2)

DSHAPE

ID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MXSHRK

MXGROW

SMETHO
D

NTRANS

GID4

GID5

GID6

PERT

DTYPE

MVFAC TO NSMOOT
R
H

GRID

GMETH

GSETID /
GID1

GID2

GID3

GID7

GID8

PATRN

PATYP

AID/XA

YA

ZA

FID/VXF

VYF

VZF

DRAW

DTYP

DAID/
XDA

YDA

ZDA

DFID/
XDF

YDF

ZDF

(10)

DRAFT
EXTR

EC ID

XE

YE

ZE

GRIDC O
N

GC METH

GC SETID
1/
GDID1

C TYPE1

C ID1

X1

Y1

Z1

GC METH

GC SETID
2/
GDID2

C TYPE2

C ID2

X2

Y2

Z2

SDC ID1

XL1

XU1

YL1

YU1

ZL1

ZU1

SDC ID2

XL2

XU2

YL2

YU2

ZL2

ZU2

SDC ON

BMESH

888

BMID

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

ID

Each DSHAPE card must have a unique ID.


No default (Integer > 0)

PERT

PERT flag indicating perturbation information is to follow.

DTYPE

Specifies the direction type for the free-shape variation (Comment 1).
Default = BOTH (GROW, SHRINK, or BOTH)

MVFACTOR

Initial limit on the movement factor of the design grids. The unit of
MVFACTOR is the average mesh size of meshes adjacent to grids defined
after GRID.
Only the initial value of this limit can be set. The values in subsequent
optimization iterations are automatically adjusted to enhance to enhance
iterative stability and convergence speed; however, they will never be
greater than the initial limit.
Default = 0.5 (Real > 0.0)

NSMOOTH

Number of grids layers NSMOOTH.


Default = 10 (Integer)

MXSHRK

Maximum shrinking distance.


No default

MXGROW

Maximum growing distance.


No default

SMETHOD

Mesh smoothing method.


Default = 1 (1 or 2)
Method 1 is faster than method 2, but method 2 is more robust in avoiding
mesh distortion.

NTRANS

Number of design grid layers in the transition zone to non-design area,


where additional treatment will be applied to produce smooth transition
(Comment 4).
Default = 0 (Integer > 0)

GRID

GRID flag indicating that a list of grid IDs is to follow. These grids are
design variables for the free-shape optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

889

Field

Contents

GMETH

Flag indicating that a list of grids is to be defined by a list of grid IDs or a


single SET reference.
Default = ID (SET or ID)

GID#

Grid identification numbers. List of grids for which this DSHAPE card is
defined.
No default (Integer > 0)

GSETID

Grid SET identification number. A grid set containing design grids for freeshape optimization.
No default (Integer > 0)

PATRN

PATRN flag indicating that variable pattern grouping is active. Indicates


that information about the pattern group will follow.

PATYP

Type of variable pattern grouping. Required if any symmetry or variable


pattern grouping is desired. Only 1-plane symmetry (TYP=10) is currently
supported.
Default = 0 (0 or 10)

AID/XA, YA, ZA

Variable pattern grouping anchor point. These fields define a point that
determines how grids are grouped into variables (See comment 3). The X,
Y, and Z values are in the global coordinate system. You may put a grid
ID in the AID/XA field to define the anchor point.
Default = origin (Real in all three fields or Integer in AID/XA field)

FID/VXF, VYF,
VZF

Direction of first vector for variable pattern grouping. These fields define
an xyz vector which determines how grids are grouped into variables
(Comment 3). The X, Y, and Z values are in the global coordinate system.
If FID is defined, it defines a vector pointing from grid AID or point (XA,
YA, and ZA) to grid FID.
If VXF, VYF, VZF are defined, it defines a vector pointing from point (XA,
YA, and ZA) to point (XA+VXF,YA+VYF,ZA+VZF). (XA, YA, and ZA) are
coordinates of the anchor point defined by AID or XA, YA, and ZA.
If all fields are blank and the PATYP field is not blank or zero, OptiStruct
gives an error.
No default

DRAW

890

DRAW flag indicating that casting constraints are being applied. Indicates
that draw direction information is to follow. Only valid for design grids on
solid elements.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

DTYP

Type of draw direction constraint to be used. SINGLE indicates that a


single die will be used, the die being withdrawn in the given draw
direction. Only SINGLE is available in 9.0.

DAID/XDA, YDA,
ZDA

Draw direction anchor point. These fields define the anchor point for draw
direction of the casting. The point may be defined by entering a grid ID in
the DAID field or by entering X, Y, and Z coordinates in the XDA, YDA, and
ZDA fields, these coordinates will be in the basic coordinate system.
Default = origin (Real in all three fields or Integer in first field)

DFID/XDF, YDF,
ZDF

Direction of vector for draw direction definition. These fields define a


point. The vector goes from the anchor point to this point. The point
may be defined by entering a grid ID in the DFID field or by entering X, Y,
and Z coordinates in the XDF, YDF, and ZDF fields, these coordinates will
be in the basic coordinate system.
No default (Real in all three fields or Integer in first field)

DRAFT

Draft angle in degrees. See comment 5.


Default = 0.0 (0.0 < Real < 90.0)

SDCON#

SDCON# flag indicating that side constraints are being applied.

SDCID#

The ID of a coordinate system which the following XL#, XU#, YL#, YU#,
ZL#, or ZU# components are resolved in.

XL#, XU#, YL#,


YU#, ZL#, ZU#

Side constraints defined by lower and upper bounds of coordinates, which


restrict the moving space of the design grids. Any of the six fields could
be blank, which means the corresponding coordinate is not constrained.

EXTR

EXTR flag indicating that extrusion constraints are being applied.


Indicates that extrusion information is to follow. Only valid for design
grids on solid elements.

ECID

The ID of a coordinate system which the following X, Y, and Z


components are resolved in.
Default = 0 (Integer > 0)
For Free-Shape 9.0, only consider two simple extrusion paths: Line and
Circle.
Line - ECID is a rectangular system.
Circle - ECID is a cylindrical system.

XE, YE, ZE

When ECID is a rectangular system ID, X, Y, and Z are components of a


vector under system EID, which define the extrusion path.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

891

Field

Contents

GRIDCON

GRIDCON flag indicating that a list of grids with associated constraints are
to follow.
Note: Grids within the smoothing zone (defined by NSMOOTH) will move
during Free-shape optimization to avoid mesh distortion without
changing the shape of the model. Users can also constrain the
movement of these grids by GRIDCON even if they are not defined
after GRID.

GCMETH

Flag indicating that a list of grids is to be defined by a list of grid IDs or a


single SET reference.
Default = ID (SET or ID)

GCSETID#

Grid SET identification numbers. IDs of certain grid SETs which are
constrained to move in a predefined manner.
No default (Integer > 0)

GDID#

IDs of certain grids which are constrained to move in a predefined manner.


No default (Integer > 0, ID must also be present in the list following the
GRID flag)

CTYPE#

Specifies the type of constraint applied to the grid GDID# (Comment 2).
No default (FIXED, DIR, or NORM)

CID#

The ID of a coordinate system which the following X, Y, and Z


components are resolved in.
Default = 0 (Integer > 0)

X#, Y#, Z#

X, Y, and Z components of a vector, which either defines the direction in


which the grid GDID# is constrained to move, or the normal of a plane on
which the grid GDID# is constrained to remain.
Default = 0.0 (Real)

BMESH

BMESH flag indicating that a BMFACE ID is to follow.

BMID

The BMFACE ID which defines a list of QUADs and/or TRIAs which define a
barrier that the design surface will not penetrate during shape
optimization.

Comments
1.

DTYPE has three distinct options:


a) GROW grids cannot move inside of the initial part boundary.

892

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

b) SHRINK grids cannot move outside of the initial part boundary.


c) BOTH grids are unconstrained.
For a more detailed description, refer to Free-shape Optimization in the Users Guide.
2.

CTYPE has three distinct options:


a) FIXED grid cannot move due to free-shape optimization.
b) DIR grid is forced to move along the vector defined by the following fields.
c) NORM grid is forced to remain on a plane for which the following fields define the
normal direction.
For a more detailed description, refer to Free-shape Optimization in the Users Guide.

3.

For a single plane of symmetry (TYP = 10), the plane is defined normal to the first vector
and is located at the anchor node.

4.

The NTRANS option allows you to achieve a smooth transition between design and nondesign regions. This additional smoothness, however, comes with an inherent cost of a
reduction in design flexibility. NTRANS improves design smoothness across the transition
zone between design and non-design regions at the expense of design flexibility.
For detailed information illustrating the working mechanism of NTRANS, refer to Defining
Free-shape Design Regions in the Users Guide.

5.

The draft angle can be specified in degrees via the DRAFT field, as illustrated in the figure
below. Geometric constraints (GRIDCON and SDCON) may not be satisfied when the draft
angle is activated:

6.

This card is represented as an optimization design variable in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

893

DSHUFFLE
Bulk Data Entry
DSHUFFLE Design Variable for Composite Shuffling Optimization
Description
Defines parameters for the generation of composite shuffling design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DSHUFFL
E

ID

ETYPE

EID1

EID2

EID3

EID4

EID5

EID6

EID7

MAXSUC
C

MANGLE

MSUC C

VSUC C

PAIR

PANGLE
1

PANGLE2

POPT

C ORE

C REP

C ANG1

C ANG2

C ANG3

C ANG4

C ANG5

C ANG6

C ANG7

VANG1

VANG2

VANG3

VANG4

VANG5

VANG6

VANG7

+
+

(10)

+
+

C OVER

VREP

+
+

RANGE

PIDSTA

PIDEND

Field

Contents

ID

Unique identification number.


No default (Integer > 0)

ETYPE

Entity type for which this DSHUFFLE card is defined.


No default (STACK, PCOMP, or PCOMPG)

894

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EID#

Entity identification numbers. List of entities of type ETYPE for which this
DSHUFFLE card is defined.
No default (Integer > 0)

MAXSUCC

MAXSUCC flag indicating that the "maximum number of successive plies"


constraint is applied. Multiple MAXSUCC constraints are allowed (see
Comment 1).

MANGLE

Ply orientation, in degrees, to which the MAXSUCC constraint is applied.


No default (Real or ALL)

MSUCC

Maximum number of successive plies for the MAXSUCC constraint.


No default (Integer > 0)

VSUCC

Allowable percentage violation for the MAXSUCC constraint. 0.0 indicates


that this constraint cannot be violated.
Default = 0.0 (Real)

PAIR

PAIR flag indicating that a pairing constraint is applied (see Comment 2).

PANGLE1

First ply orientation, in degrees, to which the PAIR constraint is applied.


No default (Real, only 45.0 allowed at this time)

PANGLE2

Second ply orientation, in degrees, to which the PAIR constraint is applied.


No default (Real, only -45.0 allowed at this time)

POPT

Pairing option. SAME indicates that the stacking sequence should remain
the same for consecutive pairs. REVERSE indicates that the stacking
sequence should be reversed for alternate pairs.
Default = blank (SAME, REVERSE or BLANK)

CORE

CORE flag indicating that a ply sequence for the core layer is defined.
Only one CORE sequence is allowed (see Comment 3).

CREP

Number of times the core ply sequence should be repeated.


Default = 1 (Integer > 0)

CANG#

Ply orientations, in degrees, defining the core.


No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

895

Field

Contents

COVER

COVER flag indicating that a ply sequence for the cover layer is defined.
Only one COVER sequence is allowed (see Comment 3).

VREP

Number of times the cover ply sequence should be repeated.


Default = 1 (Integer > 0)

VANG#

Ply orientations, in degrees, defining the cover.


No default (Real)

RANGE

Indicates that starting and ending ply identification numbers are defined in
the following fields to specify the range of plies to be shuffled. OptiStruct
will only shuffle plies between PIDSTA and PIDEND. Multiple DSHUFFLE
entries can be created to define different ply ranges.

PIDSTA

The ply identification number (starting ply) that defines the first ply in the
range to be shuffled.
No default (Integer > 0)

PIDEND

The ply identification number (ending ply) that defines the last ply in the
range to be shuffled.
No default (Integer > 0)

Comments
1.

896

The MAXSUCC constraint indicates that the stacking sequence should contain no sections
with more than a given number of successive plies with the same orientation. In the case
of symmetrical laminates, this constraint accounts for the mirrored successive plies on
both sides of the symmetry plane. In the image below, (a) shows invalid and valid
sequences for a non-symmetrical stack, and (b) shows invalid and valid sequences for a
symmetrical stack, both for MAXSUCC=3.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

The PAIR constraint indicates that 45 and -45 plies should be paired together. The
POPT option specifies how the pairing should be accomplished, as illustrated on the figure
below.

3.

The CORE and COVER constraints specify stacking sequences for the core and cover
layers respectively. Plies are listed from the bottom surface upward, in respect to the
elements normal direction. In the example below, the sequence for the core is (0, 0,
90, 90) while the sequence for the cover is defined as (90, 90, 0, 0).

Note that, for non-symmetrical laminates, COVER actually corresponds to the bottom
cover, whereas CORE corresponds to the upper cover. At this point, it is not possible to
create an actual core for non-symmetrical stacks.
4.

For a more detailed description and an example, refer to Optimization of Composite


Structures in the Users Guide.

5.

This card is represented as an optimization design variable in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

897

DSIZE
Bulk Data Entry
DSIZE Design Variable for Free-Size Optimization
Description
DSIZE defines parameters for the generation of free-size design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DSIZE

ID

PTYPE

PID1

PID2

PID3

PID4

PID5

PID6

PID7

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

(8)

(9)

(10)

Optional continuation lines for thickness definition:


(1)

(2)

(3)

(4)

THIC K

T0

T1

(5)

(6)

Optional continuation lines for stress constraint definition:


(1)

(2)

(3)

(4)

STRESS

UBOUND

(5)

(6)

Optional continuation lines for member size constraint definition:


(1)

(2)

(3)

(4)

MEMBSIZ

MINDIM

(5)

(6)

(7)

Optional continuation lines for composite manufacturing constraints definition:


(1)

(2)

(3)

(4)

(5)

(6)

(7)

C OMP

LAMTHK

LTMIN

LTMAX

LTSET

LTEXC

898

(8)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C OMP

PLYTHK

PTGRP

PTMIN

PTMAX

PTOPT

PTSET

PTEXC

C OMP

PLYPC T

PPGRP

PPMIN

PPMAX

PPOPT

PPSET

PPEXC

C OMP

PLYMAN

PMGRP

PMMAN

PMOPT

PMSET

PMEXC

C OMP

BALANC E

BGRP1

BGRP2

BOPT

C OMP

C ONST

C GRP

C THIC K

C OPT

C OMP

PLYDRP

PDGRIP

PDTYP

PDMAX

PDOPT

PDSET

PDEXC

PDDEF

PDX

PDY

PDZ

(10)

Optional continuation lines for pattern grouping constraint definition:


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PATRN

TYP

AID/XA

YA

ZA

FID/XF

YF

ZF

UC YC

SID/XS

YS

ZS

(10)

Optional continuation lines for "Master" definition for pattern repetition constraint:
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ID

C AID/
XC A

YC A

ZC A

C FID/XC F

YC F

ZC F

C SID/
XC S

YC S

ZC S

C TID/XC T

YC T

ZC T

(10)

MASTER

C OORD

Optional continuation lines for "Slave" definition for pattern repetition constraint:
(1)

(2)

(3)

(4)

(5)

(6)

SLAVE

DSIZE_ID

SX

SY

SZ

C OORD

C ID

C AID/

YC A

ZC A

Altair Engineering

(7)

(8)

(9)

C FID/XC F

YC F

ZC F

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

899

XC A
C SID/
XC S

YC S

ZC S

C TID/XC T

YC T

ZC T

(8)

(9)

(10)

(10)

Optional continuation lines for fatigue constraint definition:


(1)

(2)

(3)

(4)

FATIGUE

FTYPE

FBOUND

(5)

(6)

(7)

Optional continuation lines for zone based free-sizing definition:


(1)

(2)

(3)

GROUP

EG7

(4)

(5)

(6)

(7)

(8)

(9)

EG1

EG2

EG3

EG4

EG5

EG6

EG8

EG9

Alternate continuation line for zone based free-sizing definition (Alternate Format):
(1)

(2)

GROUP

(3)

(4)

(5)

(6)

EG1

THRU

EG2

(7)

Field

Contents

ID

Each DSIZE card must have a unique ID.

(8)

(9)

(10)

No default (Integer > 0)


PTYPE

Property type for which DSIZE card is defined.


No default (PCOMP, PCOMPG, PSHELL, or STACK)

PID#

Property identification numbers. List of properties of type


PTYPE for which this DSIZE card is defined. Use ALL in PID1
field if it applies to all properties of type PTYPE in the model.
No default (Integer > 0, or ALL)

900

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

THICK

THICK flag indicating that minimum and possibly maximum


thickness value are to follow.

T0

Minimum thickness.
For PTYPE = PSHELL, this refers to the minimum thickness of the
shell. If no value is entered for T0, the T0 value on the PSHELL
card is used. If T0 is not defined on the PSHELL card, then
T0=0.0 is assumed.
This option does not apply for PTYPE = PCOMP, PCOMPG, or
STACK.
Default = blank (Real > 0.0)

T1

Maximum thickness.
For PTYPE = PSHELL, this refers to the maximum thickness of
the shell. If no value is entered for T1, the T value on the
PSHELL card is used.
This option does not apply for PTYPE = PCOMP, PCOMPG, or
STACK.
Default = blank (Real > T0)

STRESS

STRESS flag indicating that von Mises stress constraints are


active and that an upper bound value for the stress is to follow.
See comment 4.

UBOUND

Upper bound constraint on von Mises stress.


No default (Real > 0.0)

MEMBSIZ

MEMBSIZ flag indicating that member size control is active for


the properties listed. Indicates that MINDIM is to follow.

MINDIM

Specifies the minimum diameter of members formed. This


command is used to eliminate small members. It also eliminates
checkerboard results. See comment 3.
Default = No minimum member size control (Real > 0.0)

COMP

Altair Engineering

COMP flag indicating that composite manufacturing constraints


are applied. Indicates that information about manufacturing
constraints is to follow. See comment 5.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

901

Field

Contents

LAMTHK

LAMTHK flag indicating that laminate thickness constraints are


applied. Multiple LAMTHK constraints are allowed. See
comment 5.

LTMIN

Minimum laminate thickness for the LAMTHK constraint.


Default = blank (Real > 0.0)

LTMAX

Maximum laminate thickness for the LAMTHK constraint.


Default = blank (Real > 0.0 and > LTMIN)

LTSET

Set ID of elements to which the LAMTHK constraint is applied.

LTEXC

Exclusion flag indicating that certain plies are excluded from the
LAMTHK constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PLYTHK

PLYTHK flag indicating that ply thickness constraints are


applied. Multiple PLYTHK constraints are allowed.

PTGRP

Ply orientation in degrees, ply sets or ply IDs, to which the


PLYTHK constraint is applied, depending on the PTOPT
selection.
No default (Real or Integer)

PTMIN

Minimum thickness for the PLYTHK constraint.


Default = blank (Real > 0.0)

PTMAX

Maximum thickness for the PLYTHK constraint.


Default = blank (Real > 0.0 and > PTMIN)

PTOPT

Ply selection options for the PLYTHK constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)

902

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
BYSET: Ply sets
BYPLY: Ply IDs

PTSET

Set ID of elements to which the PLYTHK constraint is applied.

PTEXC

Exclusion flag indicating that certain plies are excluded from the
PLYTHK constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PLYPCT

PLYPCT flag indicating that ply thickness percentage constraints


are applied. Multiple PLYPCT constraints are allowed.

PPGRP

Ply orientation in degrees, ply sets or ply IDs, to which the


PLYPCT constraint is applied, depending on the PPOPT selection.
No default (Real or Integer)

PPMIN

Minimum percentage thickness for the PLYPCT constraint.


Default = blank (Real > 0.0 and < 1.0)

PPMAX

Maximum percentage thickness for the PLYPCT constraint.


Default = blank (Real > 0.0, < 1.0 and > PPMIN)

PPOPT

Ply selection options for the PLYPCT constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PPSET

Set ID of elements to which the PLYPCT constraint is applied.

PPEXC

Exclusion flag indicating that certain plies are excluded from the
PLYPCT constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

903

Field

Contents
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PLYMAN

PLYMAN flag indicating that manufacturable ply thickness


constraints are applied. Multiple PLYMAN constraints are
allowed.

PMGRP

Ply orientation in degrees, ply sets or ply IDs, to which the


PLYMAN constraint is applied, depending on the PMOPT
selection.
No default (Real or Integer)

PMMAN

Manufacturable ply thickness. See comment 6.


Default = blank (Real > 0.0)

PMOPT

Ply selection options for the PLYMAN constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PMSET

Set ID of elements to which the PLYMAN constraint is applied.

PMEXC

Exclusion flag indicating that certain plies are excluded from the
PLYMAN constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default)
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

BALANCE

BALANCE flag indicating that a balancing constraint is applied.


Multiple BALANCE constraints are allowed.

BGRP1

First ply orientation in degrees, ply sets or ply IDs, to which the
BALANCE constraint is applied, depending on the BOPT
selection.
No default (Real or Integer)

904

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

BGRP2

Second ply orientation in degrees, ply sets or ply IDs, to which


the BALANCE constraint is applied, depending on the BOPT
selection.
No default (Real or Integer)

BOPT

Ply selection options for the BALANCE constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

CONST

CONST flag indicating that a constant thickness constraint is


applied. Multiple CONST constraints are allowed.

CGRP

Ply orientation in degrees, ply sets or ply IDs, to which the


CONST constraint is applied, depending on the COPT selection.
No default (Real or Integer)

CTHICK

Constant ply thickness for the CONST constraint.


No default (Real > 0.0)

COPT

Ply selection options for the CONST constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PLYDRP

Indicates that ply drop-off constraints are applied. Multiple


PLYDRP constraints are allowed.

PDGRP

Ply orientation in degrees, ply sets or ply IDs, to which the


PLYDRP constraint is applied, depending on the PDOPT selection.
No default. (Real or Integer)

PDTYP

PDTYP specifies the type of the drop-off constraint as:


PLYSLP (Default)
PLYDRP
TOTSLP

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

905

Field

Contents
TOTDRP
(see Comment 11)

PDMAX

Maximum allowed drop-off for the PLYDRP constraint.


No default (Real > 0)

PDOPT

Ply selection options for the PLYDRP constraint. Plies can be


selected based on the following:
BYANG: Orientation (Default)
BYSET: Ply sets
BYPLY: Ply IDs

PDSET

Set IDs of elements to which the PLYDRP constraint is applied.

PDEXC

Exclusion flag indicates that certain plies are excluded from the
PLYDRP constraint. The following options are supported:
NONE: Plies are not excluded.
CORE: The core is excluded. (Default).
CONST: Plies defined in the CONST constraint are excluded.
BOTH: CORE and CONST are considered.

PDDEF

Optional definition to fine-tune the drop-off constraint.


Currently only DIRECT is available to request directional dropoff, in which case PDX, PDY and PDZ specify the drop-off
direction. See comment 12.

PDX, PDY, PDZ

Used to specify the drop-off direction when DIRECT is input in


the PDDEF field. See comment 12.

PATRN

PATRN flag indicating that pattern grouping is active for the


properties listed. Indicates that information for pattern
grouping is to follow.

TYP

Indicates the type of pattern grouping requested. See


comment 1.
Default = No pattern grouping (1, 2, 3, 9, or 10)

AID/XA, YA, ZA

906

Anchor point for pattern grouping. The point may be defined by


entering a grid ID in the AID field or by entering X, Y, and Z
coordinates in the XA, YA, and ZA fields. These coordinates will
be in the basic coordinate system. See comment 1.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = origin (Real in all three fields or Integer in first field)

FID/XF, YF, ZF

First point for pattern grouping. The point may be defined by


entering a grid ID in the FID field or by entering X, Y, and Z
coordinates in the XF, YF, and ZF fields. These coordinates will
be in the basic coordinate system. See comment 1.
No default (Real in all three fields or Integer in the first field)

UCYC

Number of cyclical repetitions for cyclical symmetry. This field


defines the number of radial "wedges" for cyclical symmetry.
The angle of each wedge is computed as 360.0/UCYC. See
comment 1.
Default = blank (Integer > 0 or blank)

SID/XS, YS, ZS

Second point for pattern grouping. The point may be defined by


entering a grid ID in the SID field or by entering X, Y, and Z
coordinates in the XS, YS, and ZS fields. These coordinates will
be in the basic coordinate system. See comment 1.
No default (Real in all three fields or Integer in first field)

MASTER

MASTER flag indicating that this design variable may be used as


a master pattern for pattern repetition. See comment 2.

SLAVE

SLAVE flag indicating that this design variable is slave to the


master pattern definition referenced by the following DSIZE_ID
entry. See comment 2.

DSIZE_ID

DSIZE identification number for a master pattern definition.


No default (Integer > 0)

SX, SY, SZ

Scale factors for pattern repetition, in X, Y, and Z directions


respectively. See comment 2.
Default = 1.0 (Real > 0.0)

COORD

COORD flag indicating information regarding the coordinate


system for pattern repetition is to follow. This is required if
either MASTER or SLAVE flags are present.

CID

Coordinate system ID for a rectangular coordinate system that


may be used as the pattern repetition coordinate system. See
comment 2.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

907

Field

Contents
Default = 0 (Integer > 0)

CAID/XCA, YCA, ZCA Anchor point for pattern repetition coordinate system. The
point may be defined by entering a grid ID in the CAID field or
by entering X, Y, and Z coordinates in the XCA, YCA, and ZCA
fields. These coordinates will be in the basic coordinate
system. See comment 2.
No default (Real in all three fields or Integer in the first field)
CFID/XCF, YCF, ZCF

First point for pattern repetition coordinate system. The point


may be defined by entering a grid ID in the CFID field or by
entering X, Y, and Z coordinates in the XCF, YCF, and ZCF
fields. These coordinates will be in the basic coordinate
system. See comment 2.
No default (Real in all three fields or Integer in the first field)

CSID/XCS, YCS, ZCS Second point for pattern repetition coordinate system. The
point may be defined by entering a grid ID in the CSID field or
by entering X, Y, and Z coordinates in the XCS, YCS, and ZCS
fields. These coordinates will be in the basic coordinate
system. See comment 2.
No default (Real in all three fields or Integer in the first field)
CTID/XCT, YCT, ZCT Third point for pattern repetition coordinate system. The point
may be defined by entering a grid ID in the CTID field or by
entering X, Y, and Z coordinates in the XCT, YCT, and ZCT
fields. These coordinates will be in the basic coordinate
system. See comment 2.
No default (Real in all three fields or Integer in the first field)
FATIGUE

FATIGUE flag indicating that fatigue constraints are active and


their definition is to follow.

FTYPE

Specifies the type of fatigue constraint; it can be DAMAGE, LIFE


or FOS.

FBOUND

Specifies the bound value. If FTYPE is DAMAGE, FBOUND will be


the upper bound of fatigue damage. If FTYPE is LIFE or FOS,
FBOUND will be the lower bound of fatigue life (LIFE) or Factor
of Safety (FOS), respectively.
No default (Real)

908

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

GROUP

Specifies the definition of zone based free-sizing optimization.


Indicates that element group IDs will follow.

EG#

Element group numbers. Element groups are created through


element sets. See comment 7.
No default (Integer > 0)

THRU

This keyword can be used in the optional alternate format to


define zone based free-sizing optimization.
This keyword is used for ID range definition to indicate that all
IDs between the preceding ID (EG1) and the following ID (EG2)
are to be included in the set.

Comments
1.

There are currently five pattern grouping options for free-size optimization:
1-plane symmetry (TYP = 1)
This type of pattern grouping requires that the anchor point and the first point be defined.
A vector from the anchor point to the first point is normal to the plane of symmetry.
2-plane symmetry (TYP = 2)
This type of pattern grouping requires that the anchor point, first point, and second point
be defined. A vector from the anchor point to the first point is normal to the first plane of
symmetry. The second point is projected normally onto the first plane of symmetry. A
vector from the anchor point to this projected point is normal to the second plane of
symmetry.
3-plane symmetry (TYP = 3)
This type of pattern grouping requires that the anchor point, first point, and second point
be defined. A vector from the anchor point to the first point is normal to the first plane of
symmetry. The second point is projected normally onto the first plane of symmetry. A
vector from the anchor point to this projected point is normal to the second plane of
symmetry. The third plane of symmetry is orthogonal to both the first and second planes
of symmetry, passing through the anchor point.
Cyclic (TYP = 10)
This type of pattern grouping requires that the anchor point, first point, and number of
cyclical repetitions be defined. A vector from the anchor point to the first point defines
the axis of symmetry.
Cyclic with symmetry (TYP = 11)
This type of pattern grouping requires that the anchor point, first point, second point,
and number of cyclical repetitions be defined. A vector from the anchor point to the first

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

909

point defines the axis of symmetry. The anchor point, first point, and second point all lay
on a plane of symmetry. A plane of symmetry lies at the center of each cyclical
repetition.
For a more detailed description, refer to the Pattern Grouping for Free-Size Optimization
page contained within the Users Guide section Manufacturability for Free-Size
Optimization.
2.

Pattern repetition allows similar regions of the design domain to be linked together so as
to produce similar topological layouts. This is facilitated through the definition of "Master"
and "Slave" regions. A DSIZE card may only contain one MASTER or SLAVE flag. For both
"Master" and "Slave" regions, a pattern repetition coordinate system is required and is
described following the COORD flag. In order to facilitate reflection, the coordinate
system may be a left-handed or right-handed Cartesian system. The coordinate system
may be defined in one of two ways, listed here in order of precedence:
Four points are defined and these are utilized as follows to define the coordinate
system (this is the only way to define a left-handed system):
-

A vector from the anchor point to the first point defines the x-axis.

The second point lies on the x-y plane, indicating the positive sense of the y-axis.

The third point indicates the positive sense of the z-axis.

A rectangular coordinate system and an anchor point are defined. If only an anchor
point is defined, it is assumed that the basic coordinate system is to be used.
Multiple "Slaves" may reference the same "Master."
Scale factors may be defined for "Slave" regions, allowing the "Master" layout to be
adjusted.
For a more detailed description, refer to the Pattern Repetition for Free-Size Optimization
contained within the Users Guide section Manufacturability for Free-Size Optimization.
3.

It is recommended that a MINDIM value be chosen which allows for the formation of
members that are at least three elements thick. When pattern grouping constraints are
active, a MINDIM value of three times the average element edge length is enforced, and
user-defined values (which are smaller than this value) will be replaced by this value.

4.

Von Mises stress constraints may be defined for topology and free-size optimization
through the STRESS optional continuation line on the DTPL or the DSIZE card. There are
a number of restrictions with this constraint:
The definition of stress constraints is limited to a single von Mises permissible stress.
The phenomenon of singular topology is pronounced when different materials with
different permissible stresses exist in a structure. Singular topology refers to the
problem associated with the conditional nature of stress constraints that is the stress
constraint of an element disappears when the element vanishes. This creates another
problem in that a huge number of reduced problems exist with solutions that cannot
usually be found by a gradient-based optimizer in the full design space.
Stress constraints for a partial domain of the structure are not allowed because they
often create an ill-posed optimization problem since elimination of the partial domain
would remove all stress constraints. Consequently, the stress constraint applies to the

910

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

entire model when active, including both design and non-design regions, and stress
constraint settings must be identical for all DSIZE and DTPL cards.
The capability has built-in intelligence to filter out artificial stress concentrations
around point loads and point boundary conditions. Stress concentrations due to
boundary geometry are also filtered to some extent as they can be improved more
effectively with local shape optimization.
Due to the large number of elements with active stress constraints, no element stress
report is given in the table of retained constraints in the .out file. The iterative
history of the stress state of the model can be viewed in HyperView or HyperMesh.
Stress constraints do not apply to 1D elements.
Stress constraints may not be used when enforced displacements are present in the
model.
5.

The following manufacturing constraints are available for composite free-sizing


optimization:
Lower and upper bounds on the total thickness of the laminate (LAMTHK).
Lower and upper bounds on the thickness of a given orientation (PLYTHK).
Lower and upper bounds on the thickness percentage of a given orientation (PLYPCT).
Linking between the thicknesses of two given orientations (BALANCE).
Constant (non-designable) thickness of a given orientation (CONST).
LAMTHK, PLYTHK, PLYPCT, and PLYMAN can be applied locally to sets of elements.
There can be elements that do not belong to any set.
For a more detailed description and an example, refer to Optimization of Composite
Structures in the Users Guide.

6.

PLYMAN has no influence on the free-size phase, but this information will be translated
into the TMANUF entry on the PLY card for the sizing phase.

7.

Elements within each group will have uniform ply thicknesses.

8.

The core is designable by default. It can be made non-designable through the CONST
manufacturing constraint. To facilitate this, the keyword CORE can be used instead of a
ply ID when BYPLY is activated.

9.

The core is excluded from the LAMTHK, PLYTHK, PLYPCT and PLYMAN manufacturing
constraints by default.

10. Legacy data field PTMAN (for manufacturable ply thickness) defined on the PLYTHK and
PLYPCT entries is supported. However, it is now recommended to define the
manufacturable ply thickness in the PMMAN field through the PLYMAN continuation line as
this offers more control.
11. The options for selecting the type of drop-off constraints for PDTYP are defined for a set
of plies, as shown in the figures below:
The options for PDTYP are:
PLYSLP

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

911

PLYDRP
TOTSLP
TOTDRP

Assuming that the plies are stacked as shown above, you have the following definitions:

912

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

913

12. The optional PDDEF definition is used to fine-tune the drop-off constraint. Currently, only
the DIRECT option is available for the PDDEF field.
Field

Value

PDDEF

DIRECT This option allows you to fine-tune the drop-off


constraint by requesting directional drop-off. The direction of
drop-off can be specified by defining a directional vector with
respect to the basic coordinate system. The directional vector
is defined using the PDX, PDY and PDZ values.

PDX, PDY, PDZ

PDX, PDY and PDZ are real numbers.


These values are used to specify the drop-off direction when
DIRECT is input in the PDDEF field. They specify the three
components of a directional vector defined with respect to the
basic coordinate system.
Example:
If drop-off control is required in the X-direction, then 1,0,0
can be defined in the PDX, PDY, PDZ fields respectively. 0,1,0
can be defined for Y-direction drop-off control.

13. This card is represented as an optimization design variable in HyperMesh.

914

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DSYSID
Bulk Data Entry
DSYSID Design Objective for System Identification
Description
Defines responses and their target values for a system identification problem.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

DSYSID

DOID

LABEL

RID1

SID1

T1

W1

RID2

SID2

T2

W2

...

RIDn

SIDn

Tn

Wn

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

DSYSID

22

SYS

0.002

0.05

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

DRESP1

TZ488

DISP

488

DRESP1

TZ601

DISP

601

Altair Engineering

(5)

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

915

Field

Contents

DOID

Design objective identification number.


(Integer > 0)

LABEL

User-defined name for the response.


No default (Character)

RIDi

DRESP1, DRESP2, or DRESP3 identification number.


(Integer > 0)

SIDi

Subcase identification number; use ALL if it applies to all subcases.


Default = ALL (Integer > 0, blank or ALL)

Ti

Target value.
No default (Real)

Wi

Weighting factor.
Default = 1.0 (Real or blank)

Comments
1.

If the DSYSID entry is referenced by a DESOBJ subcase entry, a least squares objective
function is used in the optimization. The objective function is the sum of the squared,
weighted, normalized differences between the target responses and those calculated by
the finite element analysis:

If the DSYSID entry is referenced by a MINMAX or MAXMIN subcase entry, the beta
method is applied in the optimization as follows:

2.

916

DSYSID entries must have unique identification numbers with respect to DRESP1, DRESP2,
and DRESP3 entries.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

DRESP1, DRESP2, and DRESP3 entries referenced by the DSYSID entry can define only a
single response per subcase when the DESOBJ formulation is used. There is no such
limitation with the MINMAX or MAXMIN formulations.

4.

In order to use DSCREEN to control the number of retained responses when performing a
system identification, RTYPE=EQUA needs to be used on the DSCREEN entry.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

917

DTABLE
Bulk Data Entry
DTABLE Table of Constants
Description
List of constants to be used in functions defined by DEQATN.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTABLE

LABL1

VAL1

LABL2

VAL2

LABL3

VAL3

LABL4

VAL4

LABL5

VAL5

Etc

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DTABLE

123.00

321.00

55.55

AGE

21

36.0

WST

24.0

HPS

35.0

Field

Contents

LABLi

Constant Label.

(10)

(Character)
VALi

Constant value.
(Real)

Comments
1.

If a DTABLE entry has a pair of blank fields, they are ignored. If there are other
constants after the blank fields, they are read in.

2.

If fields are full of zeros, the constant label is "0", and the value is 0.0.

3.

This card is represented as an optimization table entry in HyperMesh.

918

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DTI,SPECSEL
Bulk Data Entry
DTI,SPECSEL Response Spectra Input Correlation Table
Description
Correlates spectra lines specified on TABLED1 entries with damping values.
Format
(1)

(2)

(3)

(4)

DTI

SPEC SEL

ID

TID3

DAMP3

(5)

(6)

(7)

(8)

(9)

TYPE

TID1

DAMP1

TID2

DAMP2

(10)

Example

(1)

(2)

(3)

DTI

SPEC SEL

99

0.04

(4)

(5)

(6)

(7)

(8)

(9)

0.0

0.02

Field

Contents

ID

DTI,SPECSEL identification number.

(10)

No default (Integer > 0)


TYPE

Type of spectrum. Can be either acceleration (A), velocity (V) or


displacement (D).
No default (A, V, D)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

919

Field

Contents

TID#

Identification number of a TABLED1 entry that defines a line of the


spectrum.
No default (Integer > 0)

DAMP#

Damping value assigned to TID#.


No default (Real)

Comments
1.

All DTI,SPECSEL cards must have unique ID numbers.

2.

The TID#, DAMP# pairs list the TABLED1 entry, which defines a line of the spectrum and
the damping value assigned to it. The damping value is in the units of fraction of critical
damping.

3.

Refer to Response Spectrum Analysis in the Users Guide for more details.

920

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DTI,UNITS
Bulk Data Entry
DTI,UNITS Units Definition
Description
Defines units for multi-body, component mode synthesis (flexible-body preparation), and
geometric nonlinear solution sequences.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DTI

UNITS

MASS

FORC E

LENGTH

TIME

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

DTI

UNITS

KG

Field

Contents

MASS

Units of mass. See comment 1.

(8)

(9)

(10)

Default = KG (KG, LBM, SLUG, GRAM, OZM, KLBM, MGG, SLINCH, UG, NG,
USTON, or MG)
FORCE

Units of force. See comment 2.


Default = N (N, LBF, KGF, OZF, DYNE, KN, KLBF, MN, UN, or NN)

LENGTH

Units of length. See comment 3.


Default = MM (MM, KM, M, CM, MI, FT, IN, UM, NM, ANG, YD, MIL, or
UIN)

TIME

Units of time. See comment 4.


Default = S (S, H, MIN, MS, US, NANOSEC, or D)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

921

Comments
1.

2.

922

The following options are available for input for MASS:


kg

kilogram

lbm

pound-mass

slug

slug

gram

gram

ozm

ounce-mass

klbm

kilo pound-mass (1000.lbm)

mgg

megagram

slinch

12 slugs

ug

Microgram

ng

Nanogram

uston

US ton

mg

Milligram

The following options are available for input for FORCE:


n

newton

lbf

pounds-force

kgf

kilograms-force

ozf

ounce-force

dyne

dyne

kn

kilonewton

klbf

kilo pound-force (1000.lbf)

mn

Millinewton

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

4.

un

Micronewton

nn

Nanonewton

The following options are available for input for LENGTH:


km

kilometer

meter

cm

centimeter

mm

millimeter

mi

mile

ft

foot

in

inch

um

Micrometer

nm

Nanometer

ang

Angstrom

yd

Yard

mil

Milli-inch

uin

Micro-inch

The following options are available for input for TIME:


s

seconds

hours

min

minutes

ms

milliseconds

us

Microsecond

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

923

nanosec Nanosecond
d

day

5.

PARAM, WTMASS is ignored for the multi-body and component mode synthesis (flexiblebody preparation) solution sequences. Unit data for these solution sequences is supplied
on the DTI,UNITS bulk data entry.

6.

This DTI, UNITS data entry is the same as the UNITS entry.

7.

This card is represented as a control card in HyperMesh.

924

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DTPG
Bulk Data Entry
DTPG Design Variable for Topography Optimization
Description
Defines parameters for the generation of topography design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DTPG

ID

TYPE

PID1/DVID

PID2

PID3

PID4

PID5

PID6

PID7

MW

ANG

BF

HGT

Norm/XD

YD

ZD

SKIP

PATRN

TYP

AID/XA

YA

ZA

FID/XF

YF

ZF

PATRN2

UC YC

SID/XS

YS

ZS

BOUNDS

LB

UB

INIT

(10)

Optional continuation lines for "Master" definition for pattern repetition constraint:
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ID

C AID/
XC A

YC A

ZC A

C FID/XC F

YC F

ZC F

C SID/
XC S

YC S

ZC S

C TID/
XC T

YC T

ZC T

(10)

MASTER

C OORD

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

925

Optional continuation lines for "Slave" definition for pattern repetition constraint:
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SLAVE

DTPL_ID

SX

SY

SZ

C OORD

C ID

C AID/
XC A

YC A

C SID/
XC S

YC S

(10)

ZC A

C FID/XC F

YC F

ZC F

ZC S

C TID/
XC T

YC T

ZC T

Example 1
This example defines a topography design variable which allows for swages to be created in
components referencing the PSHELL properties 1, 9, and 23. The swages will have a
minimum width of 3 units, a draw angle of 600, and a maximum height of 5 units. The draw
direction will be in the elements normal direction, but the swages may grow in either the
positive or negative direction. The swages should be grouped such that they form a
cyclical pattern of 1200 intervals about the z-axis, through the point (0,25,0), and they
also should be symmetrical about the xy plane.
(1)

(2)

(3)

(4)

(5)

(6)

DTPG

PSHELL

23

3.0

60.0

Yes

5.0

Norm

PATRN

50

0.0

25.0

0.0

PATRN2

1.0

0.0

0.0

BOUNDS

-1.0

1.0

(7)

(8)

(9)

(10)

both

0.0

1.0

0.0

Example 2
This example defines a topography design variable that references the shape variables
defined by the DVGRIDs with ID 1. The swages will have a minimum width of 5 units and a
draw angle of 750. The height and draw direction of the swages is defined by the DVGRID
cards. Also ensure that the swages can only grow in the positive direction as defined by
the DVGRID cards.

926

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

DTPG

DVGRID

5.0

75.0

YES

BOUNDS

0.0

1.0

(5)

(6)

Field

Contents

ID

Each DTPG card must have a unique ID.

(7)

(8)

(9)

(10)

No default (Integer > 0)


TYPE

Indicate whether DTPG card is defined for PSHELL, PCOMP, or


DVGRID.
No default (PSHELL, PCOMP, or DVGRID)

PID/DVID

If TYPE is PSHELL or PCOMP, then this entry is a Property


identification number. Use ALL if it applies to all properties of type
PTYPE in the model. Numerous PIDs may be given.
If TYPE is DVGRID, then this entry is the Design Variable Number for a
set of DVGRIDs. Only one DVID may be given.
Default = ALL (Integer > 0, blank or ALL)

MW

Bead minimum width. This parameter controls the width of the beads
in the model [recommended value between 1.5 and 2.5 times the
average element width]. See comment 1.
No default (Real > 0.0)

ANG

Draw angle in degrees. This parameter controls the angle of the


sides of the beads (recommended value between 60 and 75 degrees).
See comment 1.
No default (1.0 < Real < 89.0)

BF

Buffer zone. This parameter will establish a buffer zone between


elements in the design domain and elements outside the design
domain. See comment 2.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

927

Field

Contents
Default = YES (YES, or NO)

HGT

Draw height. This parameter sets the maximum height of the beads
to be drawn. This field is only valid if TYPE is PSHELL or PCOMP.
No default (Real > 0.0)

norm/XD,YD,ZD Draw direction. If norm/XD field is norm, the shape variables will be
created in the normal directions of the elements. If all the fields are
real, the shape variable will be created in the direction specified by
the xyz vector defined by the three fields. The X, Y, and Z values
are in the global coordinate system. This field is only valid if TYPE is
PSHELL or PCOMP.
Default = NORM (NORM in norm/XD field or Real in all three fields)
SKIP

Boundary skip. This parameter tells OptiStruct to leave certain nodes


out of the design domain. If none, all nodes attached to elements
whose PIDs are specified will be a part of the shape variables. If bc
or spc, any nodes which have SPC or SPC1 declarations are omitted
from the design domain. If load, any nodes which have FORCE,
FORCE1, MOMENT, MOMENT1, or SPCD declarations are omitted from
the design domain. If both, nodes with either spc or load
declarations are omitted from the design domain. This field is only
valid if TYPE is PSHELL or PCOMP.
Default = BOTH (BOTH, BC, SPC, LOAD, or NONE)

PATRN

PATRN flag indicating that variable pattern grouping is active.


Indicates that information about the pattern group will follow.

TYP

Type of variable grouping pattern. Required if any symmetry or


variable pattern grouping is desired. If zero or blank, anchor node,
first vector, and second vector definitions are ignored. If less than
20, second vector definition is ignored. See comment 4.
Default = 0 (Integer > 0)

AID/XA,YA,ZA

Variable grouping pattern anchor point. These fields define a point


that determines how grids are grouped into variables. See comment
3. The X, Y, and Z values are in the global coordinate system. You
may put a grid ID in the AID/XA field to define the anchor point.
Default = origin (Real in all three fields or Integer in AID/XA field)

928

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FID/XF,YF,ZF

Direction of first vector for variable pattern grouping. These fields


define an xyz vector which determines how grids are grouped into
variables (See comment 3). The X, Y, and Z values are in the global
coordinate system. You may put a grid ID in the FID/XF field to
define the first vector. This vector goes from the anchor point to
this grid. If all fields are blank and the TYP field is not blank or zero,
OptiStruct gives an error.
No default

PATRN2

PATRN2 flag indicating variable pattern grouping continuation card.


This card is only required when a second vector is needed to define
the pattern grouping.

UCYC

Number of cyclical repetitions for cyclical symmetry. This field


defines the number of radial "wedges" for cyclical symmetry. The
angle of each wedge is computed as 360.0 / UCYC. See comment 4.
Default = 0 (Integer > 0 or blank)

SID/XS,YS,ZS

Direction used to determine second vector for variable pattern


grouping. These fields define an xyz vector which, when combined
with the first vector, form a plane. The second vector is calculated
to lie in that plane and is perpendicular to the first vector. The
second vector is sometimes required to determine how grids are
grouped into variables (See comment 3). The X, Y, and Z values are
in the global coordinate system. You may put a grid ID in the SID/XS
field to define the second vector. This vector goes from the anchor
point to this grid. If all fields are blank and the TYP field contains a
value of 20 or higher, OptiStruct gives an error.
No default

BOUNDS

BOUNDS flag indicating that information on upper and lower limits and
the initial value for grid movement are to follow.

LB

Lower bound on variables controlling grid movement. This sets the


lower bound on grid movement equal to LB*HGT.
Default = 0.0 (Real < UB)

UB

Upper bound on variables controlling grid movement. This sets the


upper bound on grid movement equal to UB*HGT.
Default = 1.0 (Real > LB)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

929

Field

Contents

INIT

The initial value of the variables controlling grid movement. This sets
the initial value on grid movement equal to INIT*HGT.
Default = LB + factor*(UB-LB), if LB > 0.0 and UB > 0.0
Default = UB - factor*(UB-LB), if LB < 0.0 and UB < 0.0
Default = factor*max(abs(LB),UB), if LB < 0.0 and UB > 0.0
where:
factor = 0.0 if this DTPG is not used in a BEADFRAC response or is
used in a BEADFRAC response that is neither chosen as the
objective nor constrained.
factor = 0.9 if this DTPG is used in a BEADFRAC response that is
chosen as the objective.
factor = constraint_value if this DTPG is used in a BEADFRAC
response that is constrained.
(LB < Real < UB)

MASTER

MASTER flag indicating that this design variable may be used as a


master pattern for pattern repetition.

COORD

COORD flag indicating information regarding the coordinate system for


pattern repetition is to follow. This is required if either MASTER or
SLAVE flags are present.

CID

Coordinate system ID for a rectangular coordinate system that may


be used as the pattern repetition coordinate system. See comment
6.
Default = 0 (Integer > 0)

CAID/XCA,
YCA, ZCA

Anchor point for pattern repetition coordinate system. The point


may be defined by entering a grid ID in the CAID field or by entering
X, Y, and Z coordinates in the XCA, YCA, and ZCA fields. These
coordinates will be in the basic coordinate system. See comment 6.
No default (Real in all three fields or Integer in the first field)

CFID/XCF, YCF, First point for pattern repetition coordinate system. The point may
ZCF
be defined by entering a grid ID in the CFID field or by entering X, Y,

930

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
and Z coordinates in the XCF, YCF, and ZCF fields. These
coordinates will be in the basic coordinate system. See comment 6.
No default (Real in all three fields or Integer in the first field)

CSID/XCS,
YCS, ZCS

Second point for pattern repetition coordinate system. The point


may be defined by entering a grid ID in the CSID field or by entering
X, Y, and Z coordinates in the XCS, YCS, and ZCS fields. These
coordinates will be in the basic coordinate system. See comment 6.
No default (Real in all three fields or Integer in the first field)

CTID/XCT,
YCT, ZCT

Third point for pattern repetition coordinate system. The point may
be defined by entering a grid ID in the CTID field or by entering X, Y,
and Z coordinates in the XCT, YCT, and ZCT fields. These
coordinates will be in the basic coordinate system. See comment 6.
No default (Real in all three fields or Integer in the first field)

SLAVE

SLAVE flag indicating that this design variable is slaved to the master
pattern definition referenced by the following DTPL_ID entry. See
comment 6.

DTPL_ID

DTPL identification number for a master pattern definition.


No default (Integer > 0)

SX, SY, SZ

Scale factors for pattern repetition in X, Y, and Z directions


respectively. See comment 6.
Default = 1.0 (Real > 0.0)

Comments
1.

The bead minimum width and draw angles are used to determine the geometry of the
shape variables. The figure below shows a cross-section of a single shape variable fully
extended normal to the plane of the design elements. The top of the bead is flat across
the circular area with a diameter equal to the minimum bead width parameter. The sides
of the bead taper down at an angle equal to the draw angle parameter.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

931

Bead width and draw angle definitions

2.

The buffer zone is a parameter that controls how the interfaces between design and nondesign elements are treated. If active, OptiStruct will place the shape variables far
enough away from the non-design elements so that the proper bead widths and draw
angles are maintained. If inactive, the boundary between the beads and non-design
elements will have an abrupt transition. Any nodes that were skipped due to the
boundary skip parameter (field 10) will also have a buffer zone created around them.

Transitions between design and non-design elements with and without buffer zone

3.

Symmetry of topography optimization can be enforced across one, two, or three planes.
Defining symmetry planes for symmetric model and loading conditions is recommended
because automatic variable generation may not be symmetric if it is not enforced. A
symmetric mesh is not necessary, OptiStruct will create variables that are very close to
identical across the plane(s) of symmetry. If the mesh is larger on one side of the
plane(s) of symmetry than the other, OptiStruct will reflect variables created on the
positive side of the plane(s) of symmetry to the other side(s) but will not create
variables on the negative side(s) of the plane(s) of symmetry that do not overlap with
the positive side. The positive side of the plane(s) of symmetry is the one in which the
first vector, second vector, and cross product thereof are pointing toward.

4.

Variable pattern grouping may be defined for a DTPG card. OptiStruct will generate shape
variables based on the type of pattern selected in field 20. For variable grouping pattern
types 1 through 14, only the first vector and anchor node need to be defined. For
variable pattern grouping types 20 or higher, the first and second vectors need to be
defined as well as the anchor node. If a grid is used to define the first vector, the normal
vector will begin at the anchor point and extend towards the given grid (see below).
Grids or xyz data may be used for either the first vector, second vector, or anchor point
and can be a mixture, (that is the anchor point may be determined by a grid and the first
vector determined by xyz data or vice-versa).
One very useful feature for topography optimization in OptiStruct is the automatic
generation of shape variables in simple patterns. In many cases, due to manufacturing
constraints or the risk of elements being collapsed upon them during shape optimization, it

932

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

is required to create shape variables in patterns that conform to the desired shape of the
part. In basic topography optimization (TYP = 0), OptiStruct creates shape variables that
are circular. OptiStruct contains a library of different shape variable patterns which can
be accessed using the TYP parameter on the DTPG card.

Defining the first vector using a grid point

The second vector is calculated by taking the grid point or vector defined in fields 22, 23,
and 24 and projecting it onto plane 1. If a grid point was used to define the second
vector, the second vector is a vector running from the anchor node to the projected grid
point. If a vector was used to define the second vector, the base of the projected
vector is placed at the anchor point. The second vector is normal to plane 2 (see
below).

Plane 3 is determined to be normal to both plane 1 and plane 2 (see below).

5.

For a list of patterns supported by OptiStruct, refer to Pattern Grouping Options.

6.

Pattern repetition allows similar regions of the design domain to be linked together so as

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

933

to produce similar topographical layouts. This is facilitated through the definition of


"Master" and "Slave" regions. A DTPG card may only contain one MASTER or SLAVE flag.
Bead parameters will not be exported for any DTPG cards containing the SLAVE flag. For
both "Master" and "Slave" regions, a pattern repetition coordinate system is required and
is described following the COORD flag. In order to facilitate reflection, the coordinate
system may be a left-handed or right-handed Cartesian system. The coordinate system
may be defined in one of two ways, listed here in order of precedence:
Four points are defined and these are utilized as follows to the define the coordinate
system (this is the only way to define a left-handed system):
- A vector from the anchor point to the first point defines the x-axis.
- The second point lies on the x-y plane, indicating the positive sense of the y-axis.
- The third point indicates the positive sense of the z-axis.
A rectangular coordinate system and an anchor point are defined. If only an anchor
point is defined, it is assumed that the basic coordinate system is to be used.
Multiple "Slaves" may reference the same "Master."
Scale factors may be defined for "Slave" regions, allowing the "Master" layout to be
adjusted.
For a more detailed description, refer to the Pattern Repetition page contained within the
User's Guide section Manufacturability for Topography Optimization.
7.

934

This card is represented as an optimization design variable in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DTPL
Bulk Data Entry
DTPL Design Variable for Topology Optimization
Description
Defines parameters for the generation of topology design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTPL

ID

PTYPE

PID1

PID2

PID3

PID4

PID5

PID6

PID7

(8)

(9)

(10)

(8)

(9)

(10)

Optional continuation lines for minimum thickness definition:


(1)

(2)

(3)

TMIN

T0

(4)

(5)

(6)

(7)

Optional continuation lines for stress constraint definition:


(1)

(2)

(3)

(4)

STRESS

UBOUND

(5)

(6)

(7)

Optional continuation lines for member size constraint definition:


(1)

(2)

(3)

(4)

MEMBSIZ MINDIM MAXDIM

Altair Engineering

(5)

(6)

(7)

(8)

(9)

(10)

MINGAP

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

935

Optional continuation lines for mesh type definition:


(1)

(2)

(3)

MESH

MTYP

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(10)

Optional continuation lines for draw direction constraint definition:


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DRAW

DTYP

DAID/
XDA

YDA

ZDA

DFID/
XDF

YDF

ZDF

OBST

OPID1

OPID2

OPID3

OPID4

OPID5

OPID6

OPID7

OPID8

(8)

(9)

NOHOLE

STAMP

TSTAMP

Optional continuation lines for extrusion constraint definition:


(1)

(2)

(3)

EXTR

ETYP

EPATH1

EPATH2

(4)

(5)

(6)

(7)

(10)

EP1_ID1 EP1_ID2 EP1_ID3 EP1_ID4 EP1_ID5 EP1_ID6 EP1_ID7

EP1_ID8

EP2_ID1 EP2_ID2 EP2_ID3 EP2_ID4 EP2_ID5 EP2_ID6 EP2_ID7

EP2_ID8

Optional continuation lines for "Master" definition for pattern repetition constraint:

936

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

C ID

C AID/
XC A

YC A

ZC A

C FID/
XC F

YC F

ZC F

C SID/
XC S

YC S

ZC S

C TID/
XC T

YC T

ZC T

(10)

MASTER

C OORD

Optional continuation lines for "Slave" definition for pattern repetition constraint:
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SLAVE

DTPL_ID

SX

SY

SZ

C OORD

C ID

C AID/
XC A

YC A

ZC A

C FID/
XC F

YC F

ZC F

C SID/
XC S

YC S

ZC S

C TID/
XC T

YC T

ZC T

(10)

Optional continuation lines for pattern grouping constraint definition:


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PATRN

TYP

AID/XA

YA

ZA

FID/XF

YF

ZF

UC YC

SID/XS

YS

ZS

(8)

(9)

(10)

(8)

(9)

(10)

Optional continuation lines for material definition if PTYPE=COMP:


(1)

(2)

(3)

MAT

MATOPT

(4)

(5)

(6)

(7)

Optional continuation lines for fatigue constraint definition:


(1)

(2)

(3)

(4)

FATIGUE

FTYPE

FBOUND

Altair Engineering

(5)

(6)

(7)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

937

Optional continuation lines for Level Set Method (Topology Optimization) activation:
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

LEVELSE
T

HOLEIN
ST

HOLERA
D

NHOLES
X

NHOLES
Y

NHOLES
Z

(9)

(10)

Example 1

Define a topology design variable that allows the thickness of components referencing the
PSHELL properties 7, 8, and 17 to vary between 1.0 and 5.0 (the thickness defined on
PSHELL definitions with PID 7, 8, and 17 is 5.0). The optimized design should contain
members whose width is no less than 60.0 units.
(1)

(2)

(3)

(4)

(5)

(6)

DTPL

PSHELL

17

MEMBSIZ

60.0

TMIN

1.0

(7)

(8)

(9)

(10)

Example 2

Define a topology design variable for components referencing the PSOLID properties 4, 5,
and 6. The optimized design should contain members whose diameter is no less than 60.0
units. The final design will be manufactured using a casting process, where the draw
direction lies along the x-axis. The components referencing PSOLID properties 10, 11, and
12 are non-designable, but will form part of the same casting as the designable
components.

938

(1)

(2)

(3)

(4)

(5)

(6)

DTPL

PSOLID

MEMBSIZ

60.0

DRAW

SPLIT

0.0

0.0

0.0

(7)

(8)

(9)

1.0

0.0

0.0

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

Altair Engineering

OBST

10

11

12

Field

Contents

ID

Each DTPL card must have a unique ID.


No default (Integer > 0)

PTYPE

Property type for which DTPL card is defined, PBAR, PBARL,


PBEAM, PBEAML, PBUSH, PROD, PWELD, PSHELL, PCOMP, or
PSOLID.
No default (PBAR, PBARL, PBEAM, PBEAML, PBUSH, PROD,
PWELD, PSHELL, PCOMP, or PSOLID)

PID#

Property identification numbers. List of properties of type


PTYPE for which this DTPL card is defined. Use ALL in PID1
field, if it applies to all properties of type PTYPE in the
model.
If no PIDs are listed, OptiStruct will check all properties of
type PTYPE to see if they are to be included in the design
space (see help section for PCOMP, PSHELL, and PSOLID).
If any properties satisfy this search, then they will be
affected by entries on this card. In this situation (where no
PIDs are defined), only one DTPL card can be defined for the
given PTYPE.
Default = blank (Integer > 0, blank or ALL)

TMIN

TMIN flag indicating that minimum thickness value will follow.


Only valid when PTYPE = PSHELL.
If not present when PTYPE = PSHELL, then minimum
thickness will default to the T0 value defined on the PSHELL
card. If no T0 value is defined on the PSHELL card, the
minimum thickness will default to 0.0.

T0

Minimum thickness for PSHELL properties when the


referenced material is of type MAT1.
If PSHELL references a material which is not of type MAT1,
this value is ignored and T0 = 0.0 is used.
If no value is entered for T0, the T0 value on the PSHELL
card is used. If T0 is not defined on the PSHELL card, then
T0=0.0 is assumed.
Default = blank (Real > 0.0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

939

Field

Contents

STRESS

STRESS flag indicating that stress constraints are active


and that an upper bound value for stress is to follow. See
comment 1.

UBOUND

Upper bound constraint on stress.


No default (Real > 0.0)

MEMBSIZ

MEMBSIZ flag indicating that member size control is active


for the properties listed. Indicates that MINDIM and possibly
MAXDIM are to follow.

MINDIM

Specifies the minimum diameter of members formed. This


command is used to eliminate small members. It also
eliminates checkerboard results. See comment 2.
Default = No Minimum Member Size Control (Real > 0.0)

MAXDIM

Specifies the maximum diameter of members formed. This


command is used to prevent the formation of large members.
It can only be used in combination with MINDIM. See
comment 3.
Default = No Maximum Member Size Control (Real > 0.0)

MINGAP

Defines the minimum spacing between structural members


formed. This command can only be used in conjunction with
MAXDIM. See comment 3.
Default = blank (Real > MAXDIM)

MESH

MESH flag indicating that mesh type information is to follow.

MTYP

Indicates that the mesh conforms to certain rules for which


the optimizer is tuned. Currently, only the ALIGN option is
available. ALIGN indicates that when manufacturing
constraints are active, the mesh is aligned with the draw
direction or extrusion path. See comment 4.
Default = blank (ALIGN or blank)

DRAW

DRAW flag indicating that casting constraints are being


applied. Indicates that draw direction information is to
follow.
Only valid for PTYPE = PSOLID. OptiStruct will terminate
with an error if present for other PTYPEs.

940

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

DTYP

Type of draw direction constraint to be used. Can choose


between SINGLE, SPLIT, SPLIT2, or SPLIT3.
SINGLE indicates that a single die will be used, the die being
withdrawn in the given draw direction.
SPLIT allows the optimization of the splitting surface of two
dies, with both dies moving apart in the given draw
direction.
SPLIT2 and SPLIT3 provide alternative methods to optimize
the splitting surface. These should only be used in the case
where SPLIT creates non-castable cavities.
Default = SPLIT (SINGLE, SPLIT, SPLIT2, or SPLIT3)

DAID/XDA, YDA, ZDA

Draw direction anchor point. These fields define the anchor


point for draw direction of the casting. The point may be
defined by entering a grid ID in the DAID field or by entering
X, Y, and Z coordinates in the XDA, YDA, and ZDA fields,
these coordinates will be in the basic coordinate system.
Default = origin (Real in all three fields or Integer in first
field)

DFID/XDF, YDF, ZDF

Direction of vector for draw direction definition. These fields


define a point. The vector goes from the anchor point to
this point. The point may be defined by entering a grid ID in
the DFID field or by entering X, Y, and Z coordinates in the
XDF, YDF, and ZDF fields, these coordinates will be in the
basic coordinate system.
No default (Real in all three fields or Integer in first field)

OBST

OBST flag indicating that a list of PIDs will follow which are
non-designable, but their interaction with designable parts
needs to be considered with regard to the defined draw
direction. OBST stands for obstacle.
Only recognized if DRAW flag is also present on same DTPL
card. OptiStruct will terminate with an error if OBST flag is
present without DRAW flag.

OPID#

Obstacle property identification number. List of nondesignable properties that are to be considered with regard
to the defined draw direction. These must be PSOLID.
No default (Integer > 0, blank or ALL)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

941

Field

Contents

NOHOLE

Prevents the formation of through-holes in the draw


direction. Note that it does not prevent holes perpendicular
to the draw direction. The assumed minimum thickness in
the draw direction is twice the average mesh size.

STAMP

STAMP flag forcing the design to evolve into a 3D shell


structure. Indicates that thickness, TSTAMP, is to follow.
See comment 5.

TSTAMP

Defines the thickness of the 3D shell structure that is


evolved with the STAMP option. The recommended minimum
thickness is three times the average mesh size. See
comment 5.
No default (Real > 0.0)

EXTR

EXTR flag indicating that extrusion constraints are being


applied. Indicates that extrusion information is to follow.
Only valid for PTYPE = PSOLID. OptiStruct will terminate
with an error if present for other PTYPEs.

ETYP

Type of extrusion constraint to be used. Can choose


between NOTWIST or TWIST.
NOTWIST indicates that the cross-section cannot twist
about the neutral axis, in which case only one path needs to
be defined.
TWIST indicates that the cross-section can twist about the
neutral axis, in which case two paths need to be defined.
Default = NOTWIST (NOTWIST or TWIST)

EPATH1

EPATH1 flag indicating that a list of grid IDs will follow to


define the primary extrusion path.
Only recognized if EXTR flag is also present on same DTPL
card. OptiStruct will terminate with an error if EPATH1 flag
is present without EXTR flag.

EP1_ID#

Primary extrusion path identification numbers. List of grid


IDs that define the primary extrusion path.
No default (Integer > 0 or blank)

942

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EPATH2

EPATH2 flag indicating that a list of grid IDs will follow to


define the secondary extrusion path. This is only required
when ETYP has been set to TWIST.
Only recognized if EXTR flag is also present on same DTPL
card. OptiStruct will terminate with an error if EPATH2 flag
is present without EXTR flag.

EP2_ID#

Secondary extrusion path identification numbers. List of grid


IDs that define the secondary extrusion path.
No default (Integer > 0 or blank)

MASTER

MASTER flag indicating that this design variable may be used


as a master pattern for pattern repetition. See comment 7.

COORD

COORD flag indicating information regarding the coordinate


system for pattern repetition is to follow. This is required if
either MASTER or SLAVE flags are present.

CID

Coordinate system ID for a rectangular coordinate system


that may be used as the pattern repetition coordinate
system. See comment 7.
Default = 0 (Integer > 0)

CAID/XCA, YCA, ZCA

Anchor point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CAID field
or by entering X, Y, and Z coordinates in the XCA, YCA, and
ZCA fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CFID/XCF, YCF, ZCF

First point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CFID field
or by entering X, Y, and Z coordinates in the XCF, YCF, and
ZCF fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CSID/XCS, YCS, ZCS

Altair Engineering

Second point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CSID field

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

943

Field

Contents
or by entering X, Y, and Z coordinates in the XCS, YCS, and
ZCS fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CTID/XCT, YCT, ZCT

Third point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CTID field
or by entering X, Y, and Z coordinates in the XCT, YCT, and
ZCT fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

SLAVE

SLAVE flag indicating that this design variable is slaved to


the master pattern definition referenced by the following
DTPL_ID entry. See comment 7.

DTPL_ID

DTPL identification number for a master pattern definition.


No default (Integer > 0)

SX, SY, SZ

Scale factors for pattern repetition in X, Y, and Z directions


respectively. See comment 7.
Default = 1.0 (Real > 0.0)

COORD

COORD flag indicating information regarding the coordinate


system for pattern repetition is to follow. This is required if
either MASTER or SLAVE flags are present.

CID

Coordinate system ID for a rectangular coordinate system


that may be used as the pattern repetition coordinate
system. See comment 7.
Default = 0 (Integer > 0)

CAID/XCA, YCA, ZCA

Anchor point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CAID field
or by entering X, Y, and Z coordinates in the XCA, YCA, and
ZCA fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CFID/XCF, YCF, ZCF

944

First point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CFID field
or by entering X, Y, and Z coordinates in the XCF, YCF, and

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
ZCF fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CSID/XCS, YCS, ZCS

Second point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CSID field
or by entering X, Y, and Z coordinates in the XCS, YCS, and
ZCS fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

CTID/XCT, YCT, ZCT

Third point for pattern repetition coordinate system. The


point may be defined by entering a grid ID in the CTID field
or by entering X, Y, and Z coordinates in the XCT, YCT, and
ZCT fields. These coordinates will be in the basic coordinate
system. See comment 7.
No default (Real in all three fields or Integer in first field)

PATRN

PATRN flag indicating that pattern grouping is active for the


properties listed. Indicates that information for pattern
grouping is to follow.
Only valid for PTYPE = PCOMP, PSHELL, and PSOLID.
OptiStruct will terminate with an error if present for other
PTYPEs.

TYP

Indicates the type of pattern grouping requested. See


comment 10.
Default = No Pattern Grouping (1, 2, 3, 9, 10, or 11)

AID/XA, YA, ZA

Anchor point for pattern grouping. The point may be defined


by entering a grid ID in the AID field or by entering X, Y, and
Z coordinates in the XA, YA, and ZA fields. These
coordinates will be in the basic coordinate system. See
comment 10.
Default = origin (Real in all three fields or Integer in first
field)

FID/XF, YF, ZF

Altair Engineering

First point for pattern grouping. The point may be defined


by entering a grid ID in the FID field or by entering X, Y, and
Z coordinates in the XF, YF, and ZF fields. These
coordinates will be in the basic coordinate system. See
comment 10.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

945

Field

Contents
No default (Real in all three fields or Integer in first field)

UCYC

Number of cyclical repetitions for cyclical symmetry. This


field defines the number of radial "wedges" for cyclical
symmetry. The angle of each wedge is computed as 360.0 /
UCYC. See comment 10.
Default = blank (Integer > 0 or blank)

SID/XS, YS, ZS

Second point for pattern grouping. The point may be


defined by entering a grid ID in the SID field or by entering
X, Y, and Z coordinates in the XS, YS, and ZS fields. These
coordinates will be in the basic coordinate system. See
comment 10.
No default (Real in all three fields or Integer in first field)

MAT

Indicates the type of composite topology optimization. Only


considered for PTYPE=PCOMP.

MATOPT

PLY: Indicates that the optimization should be performed at


the ply level. Topology design variables are applied to each
ply individually. This method allows the optimization process
to determine which orientation is preferred for each
element.
HOMO: Indicates that the optimization should be performed
on the homogenized shell. This is the method which was
used in previous versions of OptiStruct.
Default = PLY

FATIGUE

FATIGUE flag indicating that fatigue constraints are active


and their definitions are to follow.

FTYPE

Specifies the type of fatigue constraint; it can be DAMAGE,


LIFE or FOS.

FBOUND

Specifies the bound value. If FTYPE is DAMAGE, FBOUND will


be the upper bound of fatigue damage. If FTYPE is LIFE or
FOS, FBOUND will be the lower bound of fatigue life (LIFE) or
Factor of Safety (FOS), respectively.
No default (Real)

LEVELSET

946

LEVELSET flag indicating that the Level Set method (for


topology optimization) is activated and the definitions of the
required parameters follow.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

HOLEINST

Defines the method used to insert holes into the design.


NONE/ADAPT/ALIGN/TOPDER
DEFAULT = ADAPT
NONE: Indicates that there are no holes in the initial design,
and it will work similar to shape optimization.
ADAPT: Indicates that the optimization will start with a
cheese-like initial design, where the holes are adaptively
inserted into the design domain, as illustrated in Figure 2.
This works well with irregular design domains.
ALIGN: Indicates that the optimization will start with evenly
distributed holes aligned with axes X and Y (and Z for 3D) of
the basic coordinate system, as illustrated in Figure 3. This
option is specially developed for regular design domains.
TOPDER: Indicates that OptiStruct will automatically identify
locations for the insertion of holes during the optimization
process.
If the HOLEINST Field is blank, it is set to ADAPT by default

HOLERAD

<REAL NUMBER>
DEFAULT = 4 times the average mesh size
A real number that specifies the initial radius of the holes.
If the field HOLERAD is blank, the radius will be set to 4
times the average mesh size.

NHOLESX / NHOLESY /
NHOLESZ

<POSITIVE INTEGER>
A positive integer that specifies the number of holes in X
direction (when HOLEINST= ALIGN).
If the field NHOLESX is blank, OptiStruct will automatically
assign a number based on HOLERAD and the dimensions of
the domain.
NHOLESY and NHOLESZ can be inferred by analogy.

Comments
1.

Von Mises stress constraints may be defined for topology and free-size optimization
through the STRESS optional continuation line on the DTPL or the DSIZE card. There are
a number of restrictions with this constraint:
The definition of stress constraints is limited to a single von Mises permissible stress.
The phenomenon of singular topology is pronounced when different materials with

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

947

different permissible stresses exist in a structure. Singular topology refers to the


problem associated with the conditional nature of stress constraints, that is, the stress
constraint of an element disappears when the element vanishes. This creates another
problem in that a huge number of reduced problems exist with solutions that cannot
usually be found by a gradient-based optimizer in the full design space.
Stress constraints for a partial domain of the structure are not allowed because they
often create an ill-posed optimization problem since elimination of the partial domain
would remove all stress constraints. Consequently, the stress constraint applies to the
entire model when active, including both design and non-design regions, and stress
constraint settings must be identical for all DSIZE and DTPL cards.
The capability has built-in intelligence to filter out artificial stress concentrations
around point loads and point boundary conditions. Stress concentrations due to
boundary geometry are also filtered to some extent as they can be improved more
effectively with local shape optimization.
Due to the large number of elements with active stress constraints, no element stress
report is given in the table of retained constraints in the .out file. The iterative
history of the stress state of the model can be viewed in HyperView or HyperMesh.
Stress constraints do not apply to 1D elements.
Stress constraints may not be used when enforced displacements are present in the
model.
2.

It is recommended that a MINDIM value be chosen such that it is at least 3 times, and no
greater than 12 times, the average element size. When pattern grouping, draw direction,
or extrusion constraints are active, a MINDIM value of 3 times the average element size is
enforced, and user-defined values (which are smaller than this value) will be replaced by
this value. However, in cases where a MINDIM greater than 12 times the average
element size is defined, irrespective of whether or not other manufacturing constraints
are defined, the value is reset to be equal to 12 times the average element size.
If MINDIM is defined, but no other manufacturing constraint exists, MINDIM will not be
reset to the recommended lower bound value for PTYPE = PSHELL or PSOLID, if the
defined value is less than the recommended value. For PTYPE = PCOMP, MINDIM will be
reset in the absence of manufacturing constraints.

3.

MAXDIM should at least be twice the value of MINDIM. If the input value of MAXDIM is
too small, OptiStruct automatically resets the value and an INFORMATION message is
printed.
The MAXDIM constraint introduces significant restriction to the design problem.
Therefore, it should only be used when it is a necessary design requirement. A study
without MAXDIM should always be carried out in order to compare the impact of this
additional constraint.
MAXDIM implies the application of a MINGAP constraint of the same value as MAXDIM, as
well. Therefore, for MINGAP to be effective, it should be greater than MAXDIM.
It is important to pay attention to volume fraction as the achievable volume is below 50%
when MAXDIM is defined, and further decreases as MINGAP increases.

4.

948

MTYP "ALIGN" may be used in conjunction with draw direction or extrusion manufacturing
constraints to indicate that a mesh is aligned with a draw direction or extrusion path.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1: Draw direction

Mesh 1 is "aligned" for draw direction 1 in the example shown, but not for draw direction
2.
MTYP "ALIGN" may also be used in conjunction with manufacturing constraints (minimum
member, maximum member, pattern grouping, and pattern repetition) other than draw
direction and extrusion, and Mesh 1 is considered "aligned" for those manufacturing
constraints, too.
In both cases, this will enable OptiStruct to use a smaller minimum member size and
smaller maximum member sizes. The default minimum member size is three times the
average element edge length; with an "aligned" mesh, the default size can be two times
the average element edge length.
Mesh 2 in the example shown is not "aligned" in any case.
5.

The stamping constraint is available for only one sheet, which is defined by the
combination of STAMP and DTYP as SINGLE.
It is recommended that the stamping thickness, TSTAMP, be chosen such that it is at
least 3 times the average element size. If TSTAMP is defined less than the minimum
recommended value, TSTAMP will be reset to the minimum recommended value.
STAMP and NOHOLE can be a good combination as this helps to produce a continuous/
spread shell structure.
Note that attention should be paid to the compatibility between thickness and target
volume.

6.

Extrusion constraints cannot be combined with draw direction constraints.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

949

7.

Pattern repetition allows similar regions of the design domain to be linked together so as
to produce similar topological layouts. This is facilitated through the definition of "Master"
and "Slave" regions. A DTPL card may only contain one MASTER or SLAVE flag.
Parameters will not be exported for any DTPL cards containing the SLAVE flag. For both
"Master" and "Slave" regions, a pattern repetition coordinate system is required and is
described following the COORD flag. In order to facilitate reflection, the coordinate
system may be a left-handed or right-handed Cartesian system. The coordinate system
may be defined in one of two ways, listed here in order of precedence:
Four points are defined and these are utilized as follows to define the coordinate
system (this is the only way to define a left-handed system):
- A vector from the anchor point to the first point defines the x-axis.
- The second point lies on the x-y plane, indicating the positive sense of the y-axis.
- The third point indicates the positive sense of the z-axis.
A rectangular coordinate system and an anchor point are defined. If only an anchor
point is defined, it is assumed that the basic coordinate system is to be used.
Multiple "Slaves" may reference the same "Master."
Scale factors may be defined for "Slave" regions, allowing the "Master" layout to be
adjusted.
For a more detailed description, refer to the Pattern Repetition page contained within the
User's Guide section Manufacturability for Topology Optimization.

8.

Pattern grouping is applicable for PCOMP, PSHELL, and PSOLID components only.

9.

For historic reasons, the SYMM flag may be used in place of the PATRN flag.

10. Currently there are six pattern grouping options:


1-plane symmetry (TYP = 1)
This type of pattern grouping requires the anchor point and first point to be defined. A
vector from the anchor point to the first point is normal to the plane of symmetry.
2-plane symmetry (TYP = 2)
This type of pattern grouping requires the anchor point, first point, and second point to
be defined. A vector from the anchor point to the first point is normal to the first plane
of symmetry. The second point is projected normally onto the first plane of symmetry. A
vector from the anchor point to this projected point is normal to the second plane of
symmetry.
3-plane symmetry (TYP = 3)
This type of pattern grouping requires the anchor point, first point, and second point to
be defined. A vector from the anchor point to the first point is normal to the first plane
of symmetry. The second point is projected normally onto the first plane of symmetry. A
vector from the anchor point to this projected point is normal to the second plane of
symmetry. The third plane of symmetry is orthogonal to both the first and second planes
of symmetry, passing through the anchor point.
Uniform (TYP = 9)
This type of pattern grouping does not require any additional input.

950

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Cyclic (TYP = 10)


This type of pattern grouping requires the anchor point, first point, and number of cyclical
repetitions to be defined. A vector from the anchor point to the first point defines the
axis of symmetry.
Cyclic with symmetry (TYP = 11)
This type of pattern grouping requires the anchor point, first point, second point, and
number of cyclical repetitions to be defined. A vector from the anchor point to the first
point defines the axis of symmetry. The anchor point, first point, and second point all lay
on a plane of symmetry. A plane of symmetry lies at the center of each cyclical
repetition.
For a more detailed description, refer to the Pattern Grouping page contained within the
User's Guide section Manufacturability for Topology Optimization.
11. The level set method can merge existing holes but cannot nucleate new holes in the
design domain. Therefore, creating an initial design with holes is necessary, especially for
2D design problems (For 3D design problems, new holes can be tunneled when two
surfaces merged).
12. By default, OptiStruct will automatically create a Cheese-Like initial design with holes
adaptively distributed over the design domain, as shown in Figure 2. The default hole
radius is 4.0 times the average mesh size.

Figure 2: A C heese-Like Initial design generated with (left) the default setting, and (right) double hole
radius.

13. Changing the value of HOLERAD can result in different initial designs. Figure 2 (Right)
shows an initial design filled with holes possessing a doubled hole radius when compared
to Figure 2 (Left). If the you wish to create an initial design with evenly distributed and
well aligned holes (this may be preferable for regular design domains), HOLEINST can be
set to ALIGN. The number of holes in each direction can be further specified by using
NHOLESX, NHOLESY and NHOLESZ as shown in Figure 3.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

951

Figure 3: A C heese-Like initial design with 3-by-5 evenly distributed holes generated using the following
settings: HOLEINST=ALIGN, NHOLESX=5 and NHOLESY=3.

14. Currently, level set supports both SINGLE and SPLIT draw direction constraints. When
multiple DTPL cards are involved, the draw directions need to be the same. The
information needed for draw direction constraint is read from the DTPL cards and thus no
extra settings are required.
15. This card is represented as an optimization design variable in HyperMesh.

952

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVCREL1
Bulk Data Entry
DVCREL1 Relates Design Variables to Analysis Model Element Properties
Description
Linearly relates a design variable to an analysis model element property using the equation:

Format
(1)

(2)

(3)

(4)

(5)

DVC REL1

ID

TYPE

EID

EPNAME/FID

DVID1

C OEF1

DVID2

C OEF2

(6)

(7)

(8)

(9)

(10)

C0

etc.

Field

Contents

ID

Relationship identification number. ID must be unique with respect to


other DVCREL1 cards.
No default (Integer > 0)

TYPE

Element type to be related (See DVCREL - Types)


No default (Character)

EID

Element Identification Number.


No default (Integer > 0)

EPNAME/FID Element property name, such as "K" or ZOFFS" (as in the documentation
of the element bulk data entries), or field number on an element bulk
data entry.
No default (Character or Integer > 0)
C0

Constant in relationship equation.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

953

Field

Contents
Default = 0.0 (Real)

DVIDi

DESVAR ID.
No default (Integer > 0)

COEFi

Coefficient in relationship equation.


Default = 1.0 (Real)

Comments
1.

954

This card is represented as an optimization design variable property relationship in


HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVCREL2
Bulk Data Entry
DVCREL2 Relates Design Variables to Analysis Model Element Properties via Relationship
Defined by User-supplied Equation
Description
Relates design variables to an analysis model element property using a relationship defined by
a DEQATN card. The equation inputs come from the referenced DESVAR values and constants
defined on a DTABLE card.
Format
(1)

(2)

(3)

(4)

(5)

DVC REL2

ID

TYPE

EID

EPNAME/
FID

DESVAR

DVID1

DVID2

DVID3

DVID8

DVID9

etc.

LABL1

LABL2

LABL3

LABL8

etc.

DTABLE

(6)

(7)

(8)

(9)

(10)

EQID

DVID4

DVID5

DVID6

DVID7

LABL4

LABL5

LABL6

LABL7

Field

Contents

ID

Relationship identification number. ID must be unique with respect to


other DVCREL2 cards.
No default (Integer > 0)

TYPE

Element type to be related (See DVCREL - Types)


No default (Character)

EID

Element Identification Number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

955

Field

Contents

EPNAME/FID Element property name, such as "K" or ZOFFS" (as in the documentation
of the element bulk data entries), or field number on an element bulk
data entry.
No default (Character or Integer > 0)
EQID

Equation ID of DEQATN data.


No default (Integer > 0)

DESVAR

DESVAR flag indicating DESVAR ID numbers follow.

DVID#

DESVAR ID.
No default (Integer > 0)

DTABLE

DTABLE flag indicating DTABLE labels follow.

LABL#

Constant label. Must match with a constant label of a DTABLE entry.


No default (Character)

Comments
1.

956

This card is represented as an optimization design variable property relationship in


HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVCREL - Types
Types
Depending on the TYPE entry, the FID of the appropriate design parameter can be determined
from the table below.
Type

Field
1

Field
2

Field
3

Field
4

CONM1

Field
5

Field
6

Field
7

Field
8

Field
9

M11

M21

M22

M31

M32

Field
10

FID 11-20

M33

M41

M42

M43

M44

M51

M52

M53

FID 21-30

M54

M55

M61

M62

M63

M64

M65

M66

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

X1

X2

X3

Type

Field
1

CONM2

FID 1120

Type

Field
1

I11

I21

I22

I31

I32

I33

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

CMASS2

Type

Field
1

Field
2

CMASS4

Type

Field
3
M

Field
1

CDAMP2

Altair Engineering

Field
2

Field
3
B

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

957

Type

Field
1

Type

Field
1

Field
2
Field
2

CDAMP4

Type

Field
3
Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

X1

X2

X3

Field
1

Field
2

Field
3

CBAR

FID 1120

Type

Field
1

Field
2

Field
3

W1A

W2A

W3A

W1B

W2B

W3B

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

X1

X2

X3

CBEAM

FID 1120

Type

Field
1

Field
2

Field
3

W1A

W2A

W3A

W1B

W2B

W3B

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

NSM

Field
6

Field
7

Field
8

Field
9

GE

Field
8

Field
9

GE

CONROD

Type

Field
1

Field
2

CELAS2

Type

CELAS4

958

Field
3

Field
4

Field
5

Field
1

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Field
10

Field
10

Field
10

Field
10

Altair Engineering

Type

Field
1

Type

Field
1

Field
2

Field
2

Field
3

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

CTRIA3

Type

ZOFFS

Field
1

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

CTRIA6

FID 11-20

Type

ZOFFS

Field
1

Field
2

Field
3

CQUAD4

Type

ZOFFS

Field
1

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

CQUAD8
FID 11-20

Altair Engineering

ZOFFS

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

959

DVGRID
Bulk Data Entry
DVGRID Relationship between Design Variable and Grid Point Location
Description
Defines the relationship between a design variable and a grid point location.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DVGRID

DVID

GID

C ID

C OEFF

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

DVGRID

1032

1.0

1.0

0.0

0.0

Field

Contents

DVID

DESVAR identification number.

(9)

(10)

(Integer > 0)
GID

GRID identification number.


(Integer > 0)

CID

Coordinate system identification number.


Default = 0 (Integer > 0)

COEFF

Multiplier to the vector defined in fields 6, 7, and 8.

X, Y, Z

Components of the vector defining the perturbation of the grid in the


coordinate system defined by CID.

960

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

A CID of zero or blank references the basic coordinate system.

2.

Multiple references to the same grid ID will yield a summation of perturbation vectors for
the given grid.

3.

The DVGRID data defines perturbations in the locations of the grids. The updated
location of the grid is:

where, DVj is the value of design variable j and [N]T is the coordinate transformation
matrix based on the CID and the GRID location.
4.

This card is represented as an optimization design variable in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

961

DVMBRL1
Bulk Data Entry
DVMBRL1 Relates Design Variables to Properties of MBD Entities
Description
Linearly relates a design variable to properties of an MBD entity using the equation:

Format
(1)

(2)

(3)

(4)

(5)

(6)

DVMBRL1

ID

TYPE

BID/EID

PNAME

DVID1

C OEF1

DVID2

C OEF2

(7)

(8)

(9)

(10)

C0

etc.

Example 1

To relate the translational x component of stiffness value (K1) on a CMBUSH whose ID is 22


to Design Variable 5.
(1)

(2)

(3)

(4)

(5)

DVMBRL1

88

C MBUSH

22

K1

1.

5.00

1.50

9.90

DESVAR

(6)

(7)

(8)

(9)

(10)

(9)

(10)

0.0

Example 2

To relate the mass of a rigid boy whose ID is 3 to design variable 5.


(1)

962

(2)

(3)

(4)

(5)

(6)

(7)

(8)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVMBRL1

DESVAR

88

PRBODY

1.

5.00

1.50

9.90

0.0

Field

Contents

ID

Response identity. ID must be unique with respect to other DVMBRL1 and


DVMBRL2 cards.
No default (Integer > 0)

TYPE

MBD entity type to be related (see table below).


No default (Character)

BID/EID

Body ID or Element ID number. When TYPE is PRBODY, this field is the ID


number of a rigid body. When TYPE is CMBUSH(M), CMBEAM(M), or
CMSPDP(m), this field is the ID number of a corresponding element.
No default (Integer > 0)

PNAME

Property name, such as "A" or "L" (as in the documentation of the


PRBODY, CMBEAM(M), CMBUSH(M), and CMSPDP(M) cards).
No default (Character or Integer > 0)

C0

Constant in relationship equation.


Default = 0.0 (Real)

DVIDi

DESVAR ID.
No default (Integer > 0)

COEFi

Coefficient in relationship equation.


Default = 1.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

963

Comments
1.

Available TYPEs are PRBODY, CMBUSH, CMBUSHM, CMBEAM, CMBEAMM, CMSPDP, and
CMSPDPM.

2.

MBD entity type information:


TYPE

Available PNAME

PRBODY

IXX
IYY
IZZ
IXY
IXZ
IYZ

CMBEAM/CMBEAMM

CMBUSH/CMBUSHM

964

X component of center of gravity.

Y component of center of gravity.

Z component of center of gravity.

Undeformed length along the Xaxis of


the beam.

Area of the beam cross-section.

I1

Area moment of inertia in plane 1


about the neutral axis.

I2

Area moment of inertia in plane 1


about the neutral axis.

Torsional constant.

K1 ~ K2

Area factor for shear.

K1 ~ K3

Translational stiffness.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TYPE

CMSPDP/CMSPDPM

3.

Available PNAME
K4 ~ K6

Rotational stiffness.

B1 ~ B3

Translational damping.

B4 ~ B6

Rotational damping.

P1 ~ P3

Translational preload.

P4 ~ P6

Rotational preload.

Stiffness

Damping

Unstretched length of spring damper.

PF

Preload force.

This card is represented as an optimization design variable property relationship in


HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

965

DVMBRL2
Bulk Data Entry
DVMBREL2 Relates Design Variables to Properties of MBD Entities via Relationship Defined
by User-supplied Equation
Description
Relates a design variable to properties of MBD entities using a relationship defined by a
DEQATN card. The equation inputs come from the referenced DESVAR values and the
constants defined on the DTABLE card.
Format
(1)

(2)

(3)

(4)

(5)

DVMBRL2

ID

PTYPE

BID/EID

PNAME

DESVAR

DVID1

DVID2

DVID3

DVID8

DVID9

etc.

LABL1

LABL2

LABL3

LABL8

etc.

DTABLE

(6)

(7)

(8)

(9)

(10)

EQID

DVID4

DVID5

DVID6

DVID7

LABL4

LABL5

LABL6

LABL7

Field

Contents

ID

Relationship identity. ID must be unique with respect to other DVMBRL1 and


DVMBRL2 cards.
No default (Integer > 0)

TYPE

Property type to be related (see table below).


No default (Character)

BID/EID

Body ID or Element ID number. When TYPE is PRBODY, this field is ID


number of a rigid body. When TYPE is CMBUSH(M), CMBEAM(M), or
CMSPDP(m), this field is ID number of a corresponding element.
No default (Integer > 0)

966

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

PNAME

Property name, such as "A" or "L" (as in the documentation of the PRBODY,
CMBEAM(M), CMBUSH(M), and CMSPDP(M) cards).
No default (Character or Integer > 0)

EQID

Equation ID of DEQATN data.


No default (Integer > 0)

DESVAR

DESVAR flag indicating DESVAR ID numbers follow.

DVIDi

DESVAR ID.
No default (Integer > 0)

DTABLE

DTABLE flag indicating DTABLE labels follow.

LABLi

Constant label on DTABLE card.


No default (Character)

Comments
1.

Available TYPE are PRBODY, CMBUSH, CMBUSHM, CMBEAM, CMBEAMM, CMSPDP, and
CMSPDPM.

2.

Property type table:


TYPE

Available PNAME

PRBODY

IXX
IYY
IZZ
IXY
IXZ
IYZ

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

967

TYPE

CMBEAM/CMBEAMM

CMBUSH/CMBUSHM

CMSPDP/CMSPDPM

968

Available PNAME
X

X component of center of gravity.

Y component of center of gravity.

Z component of center of gravity.

Undeformed length along the Xaxis of


the beam.

Area of the beam cross-section.

I1

Area moment of inertia in plane 1


about the neutral axis.

I2

Area moment of inertia in plane 1


about the neutral axis.

Torsional constant.

K1 ~ K2

Area factor for shear.

K1 ~ K3

Translational stiffness.

K4 ~ K6

Rotational stiffness.

B1 ~ B3

Translational damping.

B4 ~ B6

Rotational damping.

P1 ~ P3

Translational preload.

P4 ~ P6

Rotational preload.

Stiffness

Damping

Unstretched length of spring damper.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TYPE

Available PNAME
PF

3.

Preload force

This card is represented as an optimization design variable property relationship in


HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

969

DVMREL1
Bulk Data Entry
DVMREL1 Relates Design Variables to Analysis Model Material Properties
Description
Linearly relates a design variable to an analysis model material property using the equation:

Format
(1)

(2)

(3)

(4)

(5)

DVMREL1

ID

TYPE

MID

MPNAME/
FID

DVID1

C OEF1

DVID2

C OEF2

(6)

(7)

(8)

(9)

(10)

C0

etc.

Example 1

To relate the Damping Coefficient value on a MAT1 card (field 9) to Design Variable 5.
(1)

(2)

(3)

(4)

(5)

DVMREL
1

17

MAT1

22

1.0

(6)

(7)

(8)

(9)

(10)

0.0

Example 2

This example is the same as example 1 (above), except that it defines MPNAME in place of
FID.
(1)

(2)

(3)

(4)

(5)

DVMREL

17

MAT1

22

GE

970

(6)

(7)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(8)

(9)

(10)

0.0

Altair Engineering

(1)

(2)

(3)

1.0

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

DESVAR

GE

1.0

2.0

0.5

MAT1

22

2.1e5

0.3

7.85e-9

(7)

(8)

1.0

Field

Contents

ID

Relationship identification number. ID must be unique with respect to


other DVMREL1 cards.
No default (Integer > 0)

TYPE

Material type to be related (MAT1, MAT2, MAT4, MAT5, MAT8, and


MAT9).
No default (Character)

MID

Material identification number.


No default (Integer > 0)

MPNAME/FID

Material property name, such as "E" or RHO" (as in the documentation of


the material bulk data entries), or field number on a material bulk data
entry.
No default (Character or Integer > 0)

C0

Constant in relationship equation.


Default = 0.0 (Real)

DVIDi

DESVAR ID.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

971

COEFi

Coefficient in relationship equation.


Default = 1.0 (Real)

Comments
1.

972

See the DVMREL - Types section for details on the supported material fields and the
MPNAME/FID entries.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVMREL2
Bulk Data Entry
DVMREL2 Relates Design Variables to Analysis Model Material Property
Description
Relates design variables to an analysis model material property using a relationship defined by
a DEQATN card. The equation inputs come from the referenced DESVAR values and constants
defined on a DTABLE card.
Format
(1)

(2)

(3)

(4)

(5)

DVMREL2

ID

TYPE

MID

MPNAME/
FID

DESVAR

DVID1

DVID2

DVID3

DVID8

DVID9

etc.

LABL1

LABL2

LABL3

LABL8

etc.

DTABLE

(6)

(7)

(8)

(9)

(10)

EQID

DVID4

DVID5

DVID6

DVID7

LABL4

LABL5

LABL6

LABL7

Example 1
To relate the Damping Coefficient value on a MAT1 card (field 9) to some user-defined
relationship of design variables 5 and 6 and the table entry GE0.
(1)

(2)

(3)

(4)

(5)

DVMREL
2

17

MAT1

22

DESVAR

DTABLE

GE0

(6)

(7)

(8)

(9)

(10)

Example 2

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

973

This example is the same as example 1 (above), except that it defines MPNAME in place of
FID.
(1)

(2)

(3)

(4)

(5)

DVMREL
2

17

MAT1

22

GE

DESVAR

DTABLE

GE0

(6)

(7)

(8)

(9)

(10)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

DESVAR

GE1

1.0

2.0

0.5

DESVAR

GE2

1.0

1.0

0.01

DTABLE

GE0

0.01

DEQATN

MAT1

22

(7)

(8)

GE(GE1, GE2, GE0) = GE0+(GE1*GE2)


2.1e5

0.3

7.85e-9

1.0

Field

Contents

ID

Relationship identification number. ID must be unique with respect to


other DVMREL2 cards.
No default (Integer > 0)

TYPE

Material type to be related (MAT1, MAT2, MAT4, MAT5, MAT8, and


MAT9).
No default (Character)

MID

Material identification number.


No default (Integer > 0)

974

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

MPNAME/FID

Material property name, such as "E" or RHO" (as in the documentation


of the material bulk data entries), or field number on a material bulk data
entry.
No default (Character or Integer > 0)

EQID

Equation ID of DEQATN data.


No default (Integer > 0)

DESVAR

DESVAR flag indicating DESVAR ID numbers follow.

DVID#

DESVAR ID.
No default (Integer > 0)

DTABLE

DTABLE flag indicating DTABLE labels follow.

LABL#

Constant label. Must match with a constant label of a DTABLE entry.


No default (Character)

Comments
1.

See the DVMREL - Types section for details on the supported material fields and the
MPNAME/FID entries.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

975

DVMREL - Types
Types
Depending on the TYPE entry, the FID of the appropriate design parameter can be determined
from the table below.
Type

Field
1

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

NU

RHO

TREF

GE

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

G11

G12

G13

G22

G23

G33

RHO

A1

A2

A12

TREF

GE

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

Field
10

RHO

Field
9

Field
10

Field
10

MAT1

Type

Field
1

Field
2

MAT2

FID 1120

Type

Field
1

MAT4

Type

Field
1

Field
2

MAT5
FID 11-20

Type

Field
1

Field
4

Field
5

Field
6

Field
7

Field
8

KXX

KXY

KXZ

KYY

KYZ

KZZ

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

E1

E2

NU12

G12

G1,Z

G2,Z

RHO

A2

TREF

A1

FID 21-

GE

976

Field
3

HGEN

FID 1120

Field
10

HGEN

RHO

MAT8

Field
10

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

30

Type

Field
1

Field
2

MAT9

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

G11

G12

G13

G14

G15

G16

G22

FID 11-20

G23

G24

G25

G26

G33

G34

G35

G36

FID 21-30

G44

G45

G46

G55

G56

G66

RHO

A1

FID 31-40

A2

A3

A4

A5

A6

TREF

GE

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Field
10

977

DVPREL1
Bulk Data Entry
DVPREL1 Relates Design Variables to Analysis Model Properties
Description
Linearly relates a design variable to an analysis model property using the equation:

Format
(1)

(2)

(3)

(4)

(5)

(6)

DVPREL1

ID

TYPE

PID

PNAME/
FID

DVID1

C OEF1

DVID2

C OEF2

(7)

(8)

(9)

(10)

C0

etc.

Example 1
To relate the thickness value on a PSHELL card (field 4) to Design Variable 5.
(1)

(2)

(3)

(4)

(5)

DVPREL1

88

PSHELL

1.

5.00

1.50

9.90

DESVAR

(6)

(7)

(8)

(9)

(10)

0.0

Example 2
This example is the same as example 1 (above), except that it defines PNAME.

978

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

DVPREL1

88

PSHELL

1.

5.00

1.50

9.90

DESVAR

(6)

(7)

(8)

(9)

(10)

0.0

Field

Contents

ID

Relationship identification number. ID must be unique with respect to


other DVPREL1 cards.
No default (Integer > 0)

TYPE

Property type to be related (see DVPREL - Types).


No default (Character)

PID

Property identification number. When PTYPE is PCOMPG, G# may be


used where # is the GPLYID. When PTYPE is PCOMPP, P# may be used
where # is the PLY ID. See comment 2.
No default (Integer > 0)

PNAME/FID

Property name, such as "A" or "T" (as in the documentation of the


property cards), or field number in property card (see table below). For
the PSHELL property 12I/T3, only the filed number (6) is allowed. For
PBARL and PBEAML only property names are allowed, as different
sections use different fields.
No default (Character or Integer > 0)

C0

Constant in relationship equation.


Default = 0.0 (Real)

DVIDi

DESVAR ID.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

979

Field

Contents

COEFi

Coefficient in relationship equation.


Default = 1.0 (Real)

Comments
1.

TYPE cannot be PSOLID.


a) The DDVAL field of a DESVAR bulk data entry.
b) The SPTID field of a RSPINR bulk data entry.

2.

When TYPE is PCOMPG, either global plies or property specific plies may be selected.
To select property specific plies, the format is similar to that used for other property
types where the property identification number of the PCOMPG is entered in the PID field
and then either PNAME or FID is used to identify the value to be related. In this scenario,
only the property with an ID given in the PID field is affected.
To select global plies, G# is entered in the PID field where, # is the GPLYID of a global
ply. In this instance, FID is not applicable so T or THETA is used in the PNAME field to
relate either the thickness or orientation respectively. In this scenario, all plies that use
the given GPLYID are affected.
When TYPE is PCOMPP, P# is entered in the PID field where # is the ID of a PLY entity.
In this instance, FID is not applicable so T or THETA is used in the PNAME field to relate
either the thickness or orientation respectively.

3.

PBEAML definitions with more than one section definition may not be referenced by a
DVPREL1.

4.

Properties of PBARL/PBEAML have to be controlled through DIMs (cannot be controlled


directly), with the exception of NSM.

5.

When TYPE is PBARL or PBEAML, users should pay close attention to the variable ranges
to avoid invalid dimensions. For example, the inner radius of a tube cross-section cannot
exceed the outer radius. It is necessary to prevent combinations of dimensions from
taking on values that are physically meaningless. Some constraints are applied
automatically on section dimensions. The table below summarizes these constraints.
Constraints are satisfied when they are < 0.0.
Section Type Constraint
TUBE

DIM2 DIM1

DIM4 DIM2
DIM4 DIM3

980

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Section Type Constraint


DIM5 + DIM6 DIM1
CHAN

2 * DIM4 DIM2
DIM3 DIM1

DIM3 DIM2
DIM4 DIM1

BOX

DIM4 DIM1
DIM3 DIM2

CROSS

DIM4 DIM3

DIM4 DIM3

T1

DIM4 DIM1

I1

DIM3 DIM4

CHAN1

DIM3 DIM4

DIM3 DIM4

CHAN2

DIM2 DIM3
2 DIM1 DIM4

T2

DIM4 DIM1
DIM3 DIM2

BOX1

DIM4 + DIM3 DIM2


DIM5 + DIM6 DIM1

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

981

Section Type Constraint


HEXA

2 * DIM1 DIM2

HAT

2 * DIM2 DIM1
2 * DIM2 DIM3

DIM3 DIM2
DIM4 DIM1

HAT1

DIM3 DIM1
2 * DIM4 DIM2
2 * DIM4 + DIM5 DIM2

6.

982

This card is represented as an optimization design variable in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVPREL2
Bulk Data Entry
DVPREL2 Relates Design Variables to Analysis Model Properties via Relationship Defined by
User-supplied Equation
Description
Relates a design variable to an analysis model property using a relationship defined by a
DEQATN card. The equation inputs come from the referenced DESVAR values and the
constants defined on the DTABLE card.
Format
(1)

(2)

(3)

(4)

(5)

DVPREL2

ID

TYPE

PID

PNAME/
FID

DESVAR

DVID1

DVID2

DVID3

DVID8

DVID9

etc.

LABL1

LABL2

LABL3

LABL8

etc.

DTABLE

(6)

(7)

(8)

(9)

(10)

EQID

DVID4

DVID5

DVID6

DVID7

LABL4

LABL5

LABL6

LABL7

Example 1

A rectangular bar of width W and depth D is defined using the PBAR card. The required
fields on the PBAR for Area, I1 and I2 are all related to the width and depth, which are the
design variables, by the referenced equations.
(1)

(2)

(3)

(4)

(5)

DVPREL2

201

PBAR

101

DESVAR

203

PBAR

102

DVPREL2

Altair Engineering

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

983

(1)

(2)

(3)

(4)

DESVAR

204

PBAR

DESVAR

DVPREL2

(5)

(6)

(7)

(8)

(9)

(10)

103

Example 2

This example is the same as example 1 (above), except that it defines PNAME.
(1)

(2)

(3)

(4)

(5)

DVPREL2

201

PBAR

101

DESVAR

203

PBAR

I1

102

DESVAR

204

PBAR

I2

103

DESVAR

DVPREL2

DVPREL2

(6)

(7)

(8)

(9)

(10)

Associated Cards
(1)

(2)

(3)

(4)

(5)

(6)

DESVAR

6.0

1.0

10.0

DESVAR

5.0

1.0

20.0

DEQATN

101

AREA(W,D) = W*D

DEQATN

102

I1(W,D) = (W*D**3)/12

984

(7)

(8)

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

(1)

(2)

DEQATN

103

PBAR

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

I2(W,D) = (D*W**3)/12
222

0.1

19e-4

1e-3

Field

Contents

ID

Relationship identification number. ID must be unique with respect to other


DVPREL1 cards.
No default (Integer > 0)

TYPE

Property type to be related (see DVPREL - Types).


No default (Character)

PID

Property identification number. When PTYPE is PCOMPG, G# may be used


where # is the GPLYID. When PTYPE is PCOMPP, P# may be used where #
is the PLY ID. See comment 5.
No default (Integer > 0)

PNAME/
FID

Property name, such as "A" or "T" (as in the documentation of the property
cards), or field number in property card (see table below). For the PSHELL
property 12I/T3, only the filed number (6) is allowed. For PBARL and
PBEAML only property names are allowed, as different sections use different
fields.
No default (Character or Integer > 0)

EQID

Equation ID of DEQATN data.


No default (Integer > 0)

DESVAR

DESVAR flag indicating DESVAR ID numbers follow.

DVIDi

DESVAR ID.
No default (Integer > 0)

DTABLE

DTABLE flag indicating DTABLE labels follow.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

985

Field

Contents

LABLi

Constant label on DTABLE card.


No default (Character)

Comments
1.

Type cannot be PSOLID.

2.

When Type is PBARL or PBEAML, users should pay close attention to the variable ranges
to avoid invalid dimensions.

3.

PBEAML definitions with more than one section definition may not be referenced by a
DVPREL1.

4.

Properties of PBARL/PBEAML have to be controlled through DIMs (cannot be controlled


directly), with the exception of NSM.

5.

When TYPE is PCOMPG, either global plies or property specific plies may be selected.
To select property specific plies, the format is similar to that used for other property
types where the property identification number of the PCOMPG is entered in the PID field
and then either PNAME or FID is used to identify the value to be related. In this scenario,
only the property with an ID given in the PID field is affected.
To select global plies, G# is entered in the PID field where # is the GPLYID of a global ply.
In this instance, FID is not applicable so T or THETA is used in the PNAME field to relate
either the thickness or orientation respectively. In this scenario, all plies that use the
given GPLYID are affected.
When TYPE is PCOMPP, P# is entered in the PID field where # is the ID of a PLY entity.
In this instance, FID is not applicable so T or THETA is used in the PNAME field to relate
either the thickness or orientation respectively.

6.

986

This card is represented as an optimization design variable in HyperMesh.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DVPREL - Types
Types
Depending on the TYPE entry, the FID of the appropriate design parameter can be determined
from the table below.
Type

Field
1

Field
2

Field
3

Field
4

CONM2

FID 11-20

Type

Field
1

Field
8

X1

X2

X3

Field
9

Field
10

Field
9

Field
10

I22

I13

I23

I33

Field
2

Field
3

Field
4

Field
5

Field
6

Field
7

Field
8

I1

I2

NSM

D2

E1

E2

F1

F2

C1

C2

D1

FID 21-30

K1

K2

I12

Type

Field
7

I12

FID 11-20

PBARL

Field
6

I11

PBAR

Type

Field
5

Field numbers are not allowed for PBARL.


DIMi

NSM

Field
1

Field
2

Field
3

PBEAM

FID 11-20

C 1(A)

C 2(A)

K1(A)

K2(A)

Field
4

Field
5

Field
6

Field
7

Field
8

Field
9

A(A)

I1(A)

I2(A)

I12(A)

J(A)

NSM(A)

D1(A)

D2(A)

E1(A)

E2(A)

F1(A)

F2(A)

NSI(A)

NSI(B)

Field
10

FID 21-30

FID 31-40

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

987

FID 41-50

Type

M1(A)

M2(A)

M1(B)

M2(B)

N1(A)

N2(A)

N1(B)

N2(B)

Field numbers are not allowed for PBEAML.

PBEAML

Type

DIMi

NSM

Field
1

Field
2

Field
3

Field
4

Field
5

Fiel
d
6

Field
7

Field
8

Field
9

K1

K2

K3

K4

K5

K6

B1

B2

B3

B4

B5

B6

GE1

GE2

GE3

GE4

GE5

GE6

Field
3

Field
4

Field
5

Fiel
d
6

Field
7

Field
8

Field
9

Field
10

PCOMP

Z0

NSM

FID 11-20

T1

THETA1

T2

THETA4

FID 21-30

T3

THETA3

Field
3

Field
4

Field
7

Field
8

Field
9

Field
10

Z0

NSM

PBUSH

Type

Field
1

Type

Field
1

PCOMPG

FID 11-20

988

Field
2

Field
2

T1

Field
5

Fiel
d
6

Field
10

THETA1

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FID 21-20

T2

THETA2

Type

PCOMPG

Type

Field numbers do not apply for PCOMPG when referencing global plies. See
comment 2 (DVPREL1).
T

THETA

Field
1

Field
2

PCOMPP

Type

Field
1

Field
2

PDAMP

Type

Field
1

Field
2

Z0

NSM

Field
3

Field
4

Field
3

Field
1

Field
2

Field
3

Field
4

Altair Engineering

Field
2

Field
3

Fiel
d
6

Field
7

Field
8

Field
9

Field
10

Field
5

Fiel
d
6

Field
7

Field
8

Field
9

Field
10

Field
5

Fiel
d
6

Field
4

Field
1

Field
5

PMASS

Type

Field
4

PELAS

Type

Field
3

Field
5

Field
5

Field
8

Fiel
d
6

Field
4

Field
7

Field
7

Field
7

Field
8

Field
9

Field
10

Field
8

Field
9

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Field
10

Fiel
d

Field
9

Field
10

989

6
PROD

Type

Field
1

Field
2

Field
3

PSHELL

Field
1

Z1

Z2

Field
2

Field
3

Field
1

PVISC

990

Field
2

Fiel
d
6

Field
7

12*
I/T3

Field
8

Field
9

TS/T

NSM

Field
10

Field
8

Field
9

Field
10

Field
9

Field
10

ZOF
FS

Field
4

Field
5

Fiel
d
6

Field
7

NSM

F1

F2

Field
3

Field
4

Field
5

Fiel
d
6

Field
7

Field
8

CE

CR

CE

CR

PSHEAR

Type

Field
5

FID 11-20

Type

Field
4

NSM

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EDGEBH
Bulk Data Entry
EDGEBH Edge Blank Holder Definition for One-Step Stamping Simulation
Description
Defines geometry and restraining force per unit length for an edge blank holder in a one-step
stamping simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

EDGEBH

EID

S1

T2

S2

T2

BFORC E

BSID

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

EDGEBH

-1.0

1.0

1.0

1.0

100.0

Field

Contents

EID

Element identification number.


No default (Integer > 0)

S1, T1

Parametric entry points for the line.


No default (Real; | S1, T1 | < 1.0)

S2, T2

Parametric exit points for the line.


No default (Real; | S2, T2 | < 1.0)

BFORCE

Blank holder restraining force.


No default (Real)

BSID

Blank holder set identifier for retrieving the input file back to HyperForm.
Not used by the solver.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

991

Comments
1.

992

This entry is only valid with an @HyperForm statement in the first line of the input file.

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EDRAWB
Bulk Data Entry
EDRAWB Draw Bead Definition for One-Step Stamping Simulation
Description
Defines location and restraining force per unit length for a draw bead in a one-step stamping
simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

EDRAWB

EID

S1

T2

S2

T2

DFORC E

DSID

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

EDRAW
B

13

-1.0

1.0

1.0

-1.0

100.0

Field

Contents

EID

Element identification number.


No default (Integer > 0)

S1, T1

Parametric entry points for the line.


No default (Real; | S1, T1 | < 1.0)

S2, T2

Parametric exit points for the line.


No default (Real; | S2, T2 | < 1.0)

DFORCE

Draw bead restraining force per unit length.


No default (Real)

DSID

Draw bead set identifier for retrieving the input file back to HyperForm. Not
used by the solver.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

993

Comments
1. This entry is only valid with an @HyperForm statement in the first line of the input file.

994

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EIGC
Bulk Data Entry
EIGC Complex Eigenvalue Extraction Data
Description
Defines data required to perform complex eigenvalue analysis.
Format
(1)

(2)

(3)

EIGC

SID

(4)

(5)

(6)

NORM

(7)

(8)

(9)

(10)

ND0

Continuation for EIGC


ALPHAAJ OMEGAAJ

ND1

Example 1

(1)

(2)

EIC G

(3)

(4)

(5)

(6)

(7)

MAX

(8)

(9)

(10)

(9)

(10)

15

Example 2

(1)

(2)

EIGC

(3)

(4)

(5)

(6)

(7)

(8)

MAX

15

Example 3

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

995

(1)

(2)

EIGC

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MAX

1000.0

1000.0

Field

Contents

SID

Unique set identification number.

15

No default (Integer > 0)


NORM

Indicates the option for normalizing eigenvectors.


MAX - Normalize the component having the largest magnitude to a
unit value for the real part and a zero value for the imaginary part.
POINT - Normalize the component defined in fields 5 and 6 to a unit
value for the real part and a zero value for the imaginary part. The
value for NORM defaults to MAX if the magnitude of the defined
component is zero.
Default = MAX

Grid or scalar point identification number. Required if and only if NORM


= POINT.
No default (Integer > 0)

Component number. Required if and only if NORM = POINT and G is a


geometric grid point.
No default (0 < Integer < 6)

ND0

Desired number of roots and eigenvectors to be extracted.


No default (Integer > 0)

ND1

Desired number of roots and eigenvectors to be extracted.


No default (Integer > 0)

ALPHAAJ

Real part of the shift point.


Default = 0.0 (Real)

996

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

OMEGAAJ

Imaginary part of the shift point.


Default = 0.0 (Real)

Comments
1.

ND0 is required if there is no continuation, and it must be empty if there is a continuation


line.

2.

ALPHAAJ and OMEGAAJ are only useful for direct complex eigenvalue analysis. If there is
no METHOD command present in the subcase control area, the direct method is
considered for the complex eigenvalue analysis. Otherwise, modal method is used.

3.

The 3rd field is reserved for a numerical complex eigensolution (METHOD). Currently, this
field should be left blank;however, certain method types (INV, HESS and CLAN) will be
accepted, but there will be no effect on the analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

997

EIGRA
Bulk Data Entry
EIGRA Real Eigenvalue Extraction Data using Automated Multi-Level Sub-structuring
Description
Defines the data required to perform real eigenvalue analysis with the Automated Multi-Level
Sub-structuring technique.
Format
(1)

(2)

(3)

(4)

(5)

EIGRA

SID

V1

V2

ND

(6)

(7)

(8)

(9)

AMPFFAC T

(10)

NORM

Example

(1)
EIGRA

(2)

(3)

(4)

(5)

0.1

3.2

10

Field

Contents

SID

Unique set identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


V1,V2

Frequency range of interest in cycles per unit time.


V2 must be present.
Default = 0.0 for V1 (V1 < V2, Real, or blank for V1)

ND

Number of roots desired. See comment 3.


No default (Integer > 0 or blank)

AMPFFACT

998

Amplification Factor. The substructure modes are solved up to the


frequency of AMPFFACT*V2. Higher values of AMPFFACT will lead to

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
more accurate results and longer running times. See comments 6 and
9.
Default = 5.0 (Real or blank)

NORM

Method used for eigenvector normalization. If MASS, then eigenvectors


are normalized to the unit value of the generalized mass. If MAX, then
eigenvectors are normalized to the unit value of the largest
displacement in the analysis set.
Default = MASS for normal modes analysis.

Comments
1.

The units of V1 and V2 are cycles per unit time.

2.

The eigenvectors are normalized with respect to the mass matrix by default.

3.

The roots are found in order of increasing magnitude; those closest to zero are found
first. The number and type of roots to be found can be determined from the following
table.
V1

V2

ND

Number and Type of Roots Found

V1

V2

ND

Lowest ND or all in range, whichever is smaller.

V1

V2

blank

All in range.

blank

V2

ND

Lowest ND roots below V2.

blank

V2

blank

All below V2.

4.

Eigenvalues are sorted in the order of magnitude for output.

5.

In vibration analysis, small negative roots are usually computational zeros, indicating rigid
body modes. Finite negative roots are an indication of modeling problems. If V1 is set to
zero explicitly, V1 is ignored.

6.

AMPFFACT is used to increase the accuracy of the eigenvalue and eigenvectors at the
expense of slightly longer run times. It is recommended to use higher values of
AMPFFACT, between [5.0, 15.0], for solid structures like engine blocks and suspension
components.

7.

EIGRA data can be referenced by multiple normal modes subcases with different MPC set
SIDs in each subcase. However, only one can be used for modal frequency response or
modal transient analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

999

8.

EIGRA data can be referenced by multiple modal dynamic subcases, if the MPC set SID is
the same in each SUBCASE and the set of SPCD DOF is the same in each SUBCASE.
Additionally, multiple eigenvalue analysis subcases can be used with AMSES, however,
only one can be used for modal frequency response or modal transient analysis.

9.

If AMPFFACT is not specified by you and the model contains a large number of solid
elements, then the value of AMPFFACT is automatically reset to 10.

10. This card is represented as a loadcollector in HyperMesh.

1000 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

EIGRL
Bulk Data Entry
EIGRL Real Eigenvalue Extraction Data, Lanczos Method
Description
Defines data required to perform real eigenvalue analysis (vibration or buckling) with the
Lanczos Method.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

EIGRL

SID

V1

V2

ND

MSGLVL

MAXSET

SHFSC L

NORM

Example

(1)

(2)

EIGRL

(3)

(4)

(5)

0.1

3.2

10

Field

Contents

SID

Unique set identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


V1,V2

For vibration analysis: Frequency range of interest


For buckling analysis: Eigenvalue range of interest. See comments 3, 4,
and 10.
Default = blank (V1 < V2, Real, or blank)

ND

Number of roots desired. See comments 3 and 4.


No default (Integer > 0 or blank)

MSGLVL

Diagnostic level.

Altair Engineering

OptiStruct 13.0 Reference Guide 1001


Proprietary Information of Altair Engineering

Field

Contents
Default = 0 (Integer 0 through 4 or blank)

MAXSET

Number of vectors in block or set.


Default = 8 (Integer 1 through 16 or blank)

SHFSCL

For vibration analysis: Estimate of the frequency of the first flexible


mode.
For buckling analysis: Estimate of the first eigenvalue. See comment 9.
Default = blank (Real or blank)

NORM

Method used for eigenvector normalization. If MASS, then eigenvectors


are normalized to the unit value of the generalized mass (this is not a
valid option for linear buckling analysis). If MAX, then eigenvectors are
normalized to the unit value of the largest displacement in the analysis
set.
Default = MASS for normal modes analysis; Default = MAX for linear
buckling analysis (MASS or MAX)

Comments
1.

In vibration analysis, the units of V1 and V2 are cycles per unit time. In buckling analysis,
V1 and V2 are eigenvalues. Each buckling eigenvalue is the factor by which the
prebuckling state of stress is multiplied to produce buckling in the shape defined by the
corresponding eigenvector.

2.

In vibration analysis, eigenvectors are normalized with respect to the mass matrix by
default. In buckling analysis, eigenvectors are normalized to have unit value. NORM =
MASS is not a valid option for linear buckling analysis.

3.

The roots are found in order of increasing magnitude: that is, those closest to zero are
found first. The number and type of roots to be found can be determined from the
following table. In vibration analysis, blank V1 defaults to -10.
V1

V2

ND

Number and Type of Roots Found

V1

V2

ND

Lowest ND or all in range, whichever is smaller.

V1

V2

blank

All in range

V1

blank

ND

Lowest ND in range [V1, + ]

1002 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

V1

V2

ND

Number and Type of Roots Found

V1

blank

blank

Lowest root in range [V1, + ]

blank

blank

ND

Lowest ND roots in [-,+]

blank

blank

blank

Lowest root.

blank

V2

ND

Lowest ND roots below V2

blank

V2

blank

All below V2

4.

The Lanczos eigensolver provides two different ways of solving the problem. If the
eigenvalue range is defined with no upper bound (V2 blank) and less than 50 modes (ND <
50), the faster method is applied.

5.

Eigenvalues are sorted in the order of magnitude for output. An eigenvector is found for
each eigenvalue.

6.

In vibration analysis, small negative roots are usually computational zeros, indicating rigid
body modes. Finite negative roots are an indication of modeling problems. If V1 is set to
zero explicitly, V1 is ignored. It is recommended that V1 not be set to zero when
extracting rigid body modes.

7.

MSGLVL controls the amount of diagnostic output during the eigenvalue extraction. The
default value of zero suppresses all diagnostic output. A value of one prints eigenvalues
accepted at each shift. Higher values result in increasing levels of diagnostic output.

8.

MAXSET is used to limit the maximum block size in the Lanczos solver. It may be reduced
if there is insufficient memory available. The default value is recommended.

9.

A specification of SHFSCL may improve the performance of a vibration analysis. It may


also be used to improve the performance of a buckling analysis, especially when the
applied load differs from the first buckling load by orders of magnitude.

10. AMLS and AMSES eigensolvers require that V2 be specified.


11. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1003


Proprietary Information of Altair Engineering

ELEMQUAL
Bulk Data Entry
ELEMQUAL Resets the Default Bound Values for Element Quality Check
Description
Resets the default values of the warning and error bound limits for element quality check.
Format
(1)

(2)

(3)

(4)

(5)

(6)

ELEMQUAL

ETYPE

PTYPE

LTYPE

V1

V2

(7)

(8)

(9)

(10)

Example 1

For CTRIA3 elements, change the upper limit of aspect ratio for error message to 300.0
(default is 500).
(1)

(2)

(3)

(4)

ELEMQUAL

TRIA3

ARATIO

ERROR

(5)

(6)

(7)

(8)

(9)

(10)

300.0

Example 2

For CTETRA elements, change the bound limits of collapse for warning message to 0.01 and
10.0 (default lower and upper limits are 0.001 and 100.0).
(1)

(2)

(3)

(4)

(5)

(6)

ELEMQUAL

TETRA

C OLLAPSE

WARNING

0.01

10.

(7)

1004 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(8)

(9)

(10)

Altair Engineering

Field

Contents

ETYPE

Element type. Allowable entries are: TRIA3 (CTRIA3), QUAD4 (CQUAD4),


TETRA (1st-order CTETRA), TET10 (2nd-order CTETRA), PENTA (1st-order
CPENTA), PENT15 (2nd-order CPENTA), HEXA (1st-order CHEXA), HEX20
(2nd-order CHEXA), PYRA (1st-order CPYRA), PYRA13 (2nd-order CPYRA),
TAXI3 (1st-order CTAXI or CTRIAX6), TAXI6 (2nd-order CTAXI or
CTRIAX6), GASK8 (CGASK8), GASK16 (CGASK16), GASK6 (CGASK6), and
GASK12 (CGASK12).
No default (TRIA3, QUAD4, TETRA, TET10, PENTA, PENT15, HEXA, HEX20,
PYRA, PYRA13, TAXI3, TAXI6, GASK8, GASK16, GASK6, or GASK12).

PTYPE

Geometric property type. Allowable entries are: ARATIO (Aspect Ratio),


SKEW (Skew Angle), TAPER (Face Taper), WARP (Warp Angle), TWIST
(Twist Angle), EDGE (Edge Angle), COLLAPSE, ANGLE (Vertex Angle),
HOENOR (Hoe Normal Offset), HOETAN (Hoe Tangent Offset).
No default (ARATIO, SKEW, TAPER, WARP, TWIST, EDGE, COLLAPSE,
ANGLE, HOENOR, or HOETAN).

LTYPE

Type of bound limits.


No default (WARNING or ERROR)

V1

Lower bound value.


No default (Real)

V2

Upper bound value.


No default (Real)

Comments
1.

Element quality checks and their default settings are described in the Element Quality
Check section.

2.

All specified values (V1 and V2) are checked against the corresponding limits used for
validity check. Data outside the validity range is ignored.

Altair Engineering

OptiStruct 13.0 Reference Guide 1005


Proprietary Information of Altair Engineering

ELIST
Bulk Data Entry
ELIST Damp Shell Elements for a Fluid Volume
Description
Specifies damp shell elements for a fluid volume. ELIST entries are referenced by the MFLUID
entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

ELIST

LID

EID1

EID2

EID3

EID4

EID5

EID6

EID7

EID8

EID9

EID10

- etc -

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

ELIST

25

47

22

THRU

35

-56

-57

Field

Contents

LID

List of identification number.

(9)

(10)

No default (Integer > 0)


EID

Element identification number of CQUAD4, CTRIA3, CQUADR, and


CTRIAR elements that are damp in the fluid volume.

Comments
1.

By default, for elements only damp on one side (see WSURF1 on MFLUID entry), the damp
side of an element is on the same side of the elements normal. But a negative EIDi
indicates that the fluid is opposite to the normal. If there are negative EIDis specified in
a "THRU" range, then both EIDis in the range must be negative.

1006 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

Alternatively, the SURF and SET entries may be used to define damp elements but the
SURF and SET entries may not be combined in the single with ELIST entries to define
damp elements. For example, if any MFLUID references a missing ELIST,25, then the
program will not search for a SET,25 if a ELIST card exists in the deck.

3.

ELIST entries are internally converted to SET entries. The continuation is optional.

Altair Engineering

OptiStruct 13.0 Reference Guide 1007


Proprietary Information of Altair Engineering

ENDMETADATA
Bulk Data Entry
ENDMETADATA Indicates the end of metadata that is to be passed to the metadata output
file.
Description
ENDMETADATA indicates the end of metadata that is to be passed to the metadata output file.
Metadata between the METADATA and ENDMETADATA commands is passed to the
<filename>_metadata.xml file.

Example

METADATA
This line will be passed to the filename_metadata.xml file.
So will this information: Color=blue
ENDMETADATA
Comments
1.

There can be two sections of metadata; one in the Solution Control section and one in
the Bulk Data section.

2.

Metadata can be used to pass information from the pre-processor seamlessly through the
solver to a post-processing program.

1008 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

END
Bulk Data Entry
END Indicates the end of data input for a specific entity
Description
The END bulk data entry indicates the end of data that is used to describe a specific entity
(or entities) for inclusion in a model. The END entry is used in conjunction with the BEGIN
entry to define the data required for a specific entity.
Format
(1)

(2)

(3)

(4)

END

TYPE

NAME

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

END

FEMODE
L

Bumper

(1)

(2)

(3)

END

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

HYPRBEAM Square

Field

Contents

TYPE

Specifies the entity type that will be defined by the END data entry (see
comment 2).
(HYPRBEAM or FEMODEL)

NAME

This field specifies the name of the entity that is defined by the END entry
(see comment 2).
(Character String)

Altair Engineering

OptiStruct 13.0 Reference Guide 1009


Proprietary Information of Altair Engineering

Comments
1.

The BEGIN and END bulk data entries can be used in conjunction to define a part within
the full model (for TYPE = FEMODEL).

2.

TYPE = HYPRBEAM:
Data required for the definition of an arbitrary beam section will be specified between the
BEGIN and END data entries.
TYPE = FEMODEL:
In a model containing multiple parts, the parts are included within the full model specifying
part data between the BEGIN and END bulk data entries (the INCLUDE entry can also be
used for part data referencing). The name of the included part should be specified in the
NAME field.

3.

The INCLUDE entry, similar to almost any other bulk data entry, is allowed between BEGIN
and END entries. However, BEGIN and END should exist in the same file.

4.

Models are often defined in separate files, and the block (BEGIN END) contains only
INCLUDE entries. It is possible to duplicate a single part by including the same file(s) in
different BEGIN-END blocks.

5.

There can be multiple sections of arbitrary beam data; one for each beam section.

6.

An example set of data for the definition of an arbitrary beam section is as follows:
BEGIN,HYPRBEAM,SQUARE
$
GRIDS,1,0.0,0.0
GRIDS,2,1.0,0.0
GRIDS,3,1.0,1.0
GRIDS,4,0.0,1.0
$
CSEC2,10,100,1,2
CSEC2,20,100,2,3
CSEC2,30,100,3,4
CSEC2,40,100,4,1
$
PSEC,100,1000,0.1
$
END,HYPRBEAM

1010 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ERPPNL
Bulk Data Entry
ERPPNL Panel Definition for Equivalent Radiated Power Output
Description
Defines one or more sets of elements as panels for equivalent radiated power output for a
frequency response analysis of a coupled fluid-structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ERPPNL

NAME1

SID1

NAME2

SID2

NAME3

SID3

NAME4

SID4

NAME5

SID5

Field

Contents

NAME#

Panel label.

(10)

No default (Character string)


SID#

Set identification number for a set of elements.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1011


Proprietary Information of Altair Engineering

ESLTADD
Bulk Data Entry
ESLTADD Combination of selected time steps for Geometric Nonlinear ESLM Optimization or a
Multi-body Dynamics ESLM Optimization
Description
Defines a combined time step selection set as a union of selected time steps defined via
ESLTIME entries for Geometric Nonlinear ESLM optimization or a Multi-body Dynamics ESLM
optimization.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ESLTADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

etc.

(10)

Example

(1)

(2)

(3)

(4)

(5)

ESLTADD

101

11

13

Field

Contents

SID

Set identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
Si

Set identification numbers of time step selections defined via ESLTIME bulk
data entries.
(Integer > 0)

Comments
1.

ESLTADD can be selected within the subcase information section using the command
ESLTIME=SID.

2.

Si should be unique and may not be the identification number of a set defined by another
ESLTADD entry.

1012 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

ESLTADD entries take precedence over ESLTIME entries. If both entries have the same
SID, only the ESLTADD entry will be used.

4.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1013


Proprietary Information of Altair Engineering

ESLTIME
Bulk Data Entry
ESLTIME Time Step selection control for Geometric Nonlinear Response ESLM Optimization
and Multi-body Dynamics ESLM Optimization
Description
Defines time step selection control for geometric nonlinear response ESL Optimization and
Multi-body dynamics ESLM optimization.
Format
(1)

(2)

(3)

(4)

(5)

(6)

ESLTIME

SID

TLB

TUB

RID1

LB1

UB1

TYPE1

RID2

LB2

UB2

TYPE2

RID3

LB3

UB3

TYPE3

(7)

(8)

(9)

(10)

...

Example

(1)

(2)

ESLTIME

100

11

(3)

(4)

-19.9

99.9

12

(5)

(6)

(7)

(8)

(9)

(10)

13

1014 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

SID

Set identification number.


(Integer > 0)

RID

Identification number of a DRESP1, DRESP2, or DRESP3 bulk data


entry.
(Integer > 0)

TLB

Lower bound of time.


No default (Real > 0.0, or blank)

TUB

Upper bound of time.


No default (Real > 0.0, or blank)

LB#

Lower bound on response.


(Real, or blank)

UB#

Upper bound on response.


(Real, or blank)

TYPE#

Flag to select the time steps at which the highest or lowest


response values or peaks or troughs of the response, occur.
= 1, select the highest response value
= -1, select the lowest response value
= 2, select the response peaks
= -2, select the response troughs
(Integer = -2, -1, 1, 2, or blank)

Comments
1.

ESLTIME should be selected by the Subcase Information command ESLTIME = SID or in


the bulk data section by the ESLTADD entry. It can only be selected in geometric
nonlinear analysis subcases which are defined by an ANALYSIS = NLGEOM, IMPDYN or
EXPDYN subcase entry, and for geometric nonlinear response ESL Optimization.

2.

The SID and RID fields cannot be left blank. Other fields, if blank, will be ignored.

3.

Lower bounds TLB and LB must be smaller than upper bounds TUB and UB respectively.

Altair Engineering

OptiStruct 13.0 Reference Guide 1015


Proprietary Information of Altair Engineering

4.

The TLB and TUB fields can be used to define the range of time. OptiStruct will then
select the most critical time steps in the time range with higher priority for ESL generation
(Figure 1). If more time steps are required, then the critical time steps outside the time
range will be taken into account.

5.

Using fields LB and UB, the user can define the range of a specific response. OptiStruct
will then select the time steps with response values in this range for ESL generation
(Figure 1).

Figure 1: Time step selection based on time and response range.

6.

If TYPE = 1, time steps which have the highest response values will be selected.
If TYPE = -1, time steps which have the lowest response values will be selected.

Figure 2: Example illustration depicting TYPE=1 and TYPE=-1 response selection

7.

If TYPE = 2, time steps at which response peaks occur will be selected.


If TYPE = -2, time steps at which response troughs occur will be selected.

1016 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 3: Example illustration depicting TYPE=2 and TYPE=-2 response selection.

8.

If a NLGEOM, IMPDYN or EXPDYN subcase is referenced by a DRESP2 entry with DRESP1L


or DRESP2L definition, the generated ESL subcase at the most critical time step will be
used for this DRESP2(DRESP1L/DRESP2L) entry.

9.

All continuation lines on the ESLTIME entry are ignored in Multi-body dynamics ESLM
optimization. Only the first line (ESLTIME, SID, TLB, TUB) is considered.

10. DOPTPRM, ESLSTOL is ignored, if ESLTIME is defined in the model.

Altair Engineering

OptiStruct 13.0 Reference Guide 1017


Proprietary Information of Altair Engineering

FATDEF
Bulk Data Entry
FATDEF Elements for Fatigue Analysis
Description
Defines elements, and associated fatigue properties, for consideration in a fatigue analysis.
Format
(1)

(2)

(3)

FATDEF

ID

TOPSTR

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Optional continuation lines for selecting elements, and associated fatigue properties, using
element sets (ELSET)
ELSET

ELSID1

PFATID1

ELSID2

PFATID2

ELSID3

PFATID3

ELSID4

PFATID4

Optional continuation lines for selecting elements and associated fatigue properties through
referenced properties (PSHELL)
PSHELL

PID1

PFATID1

PID2

PFATID2

PID3

PFATID3

PID4

PFATID4

Optional continuation lines for selecting elements and associated fatigue properties through
referenced properties (PSOLID)
PSOLID

PID1

PFATID1

PID2

PFATID2

PID3

PFATID3

PID4

PFATID4

1018 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Optional continuation lines for excluding elements using element sets (ELSET)
XELSET

XELSID1 XELSID2 XELSID3 XELSID4 XELSID5 XELSID6 XELSID7


XELSID8

Optional continuation lines for excluding individual elements


XELEM

XEID1

XEID2

XEID3

XEID4

XEID5

XEID6

XEID7

XEID8

Field

Contents

ID

Each FATDEF card must have a unique ID. FATDEF Subcase Information entry
may reference this ID.
No default (Integer > 0)

TOPSTR

Top stress fraction. Elements with combined stress not in this top fraction of
each MATFAT group will be screened out and have no results. This field is
ignored in fatigue analysis on a transient subcase.
Default = blank (100% will be used internally), (0.0 < Real < 1.0)

ELSET

ELSET flag indicating that a list of pairs of ELSET and PFAT IDs will follow,
defining elements, and their associated fatigue properties, for consideration in
fatigue analyses where this FATDEF is selected.

ELSID#

Element Set ID. Elements in this set will be considered in fatigue analyses
where this FATDEF is selected.
No default (Integer > 0)

PFATID#

Fatigue property ID. This is identification number of a PFAT entry, which


indicates the fatigue property used by the preceding elements defined by
ELSID# or PID#.

PSHELL

PSHELL flag indicating that a list of pairs of PSHELL property IDs and PFAT
IDs will follow; defining elements and their associated fatigue properties for
consideration in fatigue analyses where this FATDEF is selected.

Altair Engineering

OptiStruct 13.0 Reference Guide 1019


Proprietary Information of Altair Engineering

Field

Contents

PSOLID

PSOLID flag indicating that a list of pairs of PSOLID property IDs and PFAT
IDs will follow; defining elements and their associated fatigue properties for
consideration in fatigue analyses where this FATDEF is selected.

PID#

Property ID. This is identification number of a PSHELL or PSOLID entry.


Elements referencing any property with this ID will be considered in fatigue
analyses where this FATDEF is selected.
No default (Integer > 0)

XELSET

XELSET flag indicating that IDs of elements sets excluded from fatigue
analysis follow.

XELSID#

Element set ID. Elements in these sets will be excluded from fatigue analyses
where this FATDEF is selected.
No default (Integer > 0)

XELEM

XELEM flag indicating that IDs of elements excluded from fatigue analysis
follow.

XEID#

Element ID. These elements will be excluded from fatigue analyses where this
FATDEF is selected.
No default (Integer > 0)

Comments
1.

At least one of the optional continuation lines ELSET or PROP must be present.

2.

This card is represented as a loadcollector in HyperMesh.

1020 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FATEVNT
Bulk Data Entry
FATEVNT Loading Event Definition for Fatigue Analysis
Description
Defines loading events for fatigue analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

FATEVNT

ID

FLOAD1

FLOAD2

FLOAD3

FLOAD4

FLOAD5

FLOAD6

FLOAD7

FLOAD8

...

...

(10)

Field

Contents

ID

Each FATEVNT card must have a unique ID. This identifier may be referenced
by a FATSEQ definition.
No default (Integer > 0)

FLOAD#

Identification number of a FATLOAD entry (see comments 1, 3 and 4).


No default (Integer > 0)

Comments
1.

FATLOAD entries referenced on this bulk data entry may reference different subcases.

2.

Identification numbers of FATSEQ and FATEVNT share the same ID pool.

3.

These FATLOAD entries should reference the subcase types. For example, either static
subcases or transient subcases can be referenced, but not both. Referencing a
combination of subcase types via FATLOAD entries on the same FATEVNT entry is not
allowed.

4.

If a specified FATLOAD entry references a transient subcase, only one FATLOAD entry is
allowed.

5.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1021


Proprietary Information of Altair Engineering

FATLOAD
Bulk Data Entry
FATLOAD - Fatigue Load
Description
Defines fatigue loading parameters.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

FATLOAD

ID

TID

LC ID

LDM

Scale

Offset

(8)

(9)

Field

Contents

ID

Each FATLOAD card must have a unique ID. This identifier may be
referenced by a FATEVNT definition.

(10)

No default (Integer > 0)


TID

Identification number of TABFAT entry.


(Integer > 0 or blank)
If LCID references a linear-static subcase, TID should be a positive integer
(Integer > 0).
If LCID references transient subcase, TID should be blank.

LCID

Subcase identification number of a linear-static or transient analysis


subcase.
No default (Integer > 0)

LDM

The magnitude of the FEA load in the same units as those for the time
history. It is ignored in fatigue analyses based on a transient analysis
subcase (see comment 2).
Default = 1.0 (Real)

Scale

Scale factor applied to the load or time history. It is ignored in fatigue


analyses based on a transient analysis subcase.
Default = 1.0 (Real)

1022 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Offset

Offset applied to the load or time history. It is ignored in fatigue analyses


based on a transient analysis subcase.
Default = 0.0 (Real)

Comments
1.

This magnitude is used as a scale factor to normalize the finite element stresses/strains
to obtain the stress/strain distribution due to a unit loading.

2.

The sequence below depicts how LDM, Scale and Offset values work together to scale
the FEA stress tensor at time t:

ij

(t )

Where,

ij . FEA

LDM

( P (t ) Scale Offset )

is the result stress tensor at time t.

is the stress tensor from static analysis.

P(t) is the y point value of load-time history at time t.


3.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1023


Proprietary Information of Altair Engineering

FATPARM
Bulk Data Entry
FATPARM - Fatigue Analysis Parameters
Description
This bulk data entry can be used to define parameters required for a Fatigue Analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

FATPARM

ID

Type

STRESS

C ombinatio
n

C orrectio
n

StressUni
t

Plasticit
y

RAINFLO
W

RType

GateRel

C ERTNTY

SurvC ert

FOS

FOSType

(7)

(8)

(9)

(10)

Field

Contents

ID

Each FATPARM card must have a unique ID. The FATPARM Subcase Information
entry may reference this identifier.
No default (Integer > 0)

Type

Type of fatigue analysis that is defined.


Default = SN
(SN = Stress Life, EN = Strain Life, FOS = Factor of Safety Analysis - see
comment 9)
(NSTRESS is also supported for Stress Life for compatibility)

STRESS

STRESS flag indicating that parameters are to follow which define how the
stress is used in fatigue calculation. This flag and following parameters will be
used only when the "Type" field is set to SN or EN.

1024 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Combinatio
n

Default = ABSMAXPR
(ABSMAXPR = Abs Max Principal
MINPRINC = Min Principal
SGVON = Signed von Mises
SGTRESCA = Signed Tresca
XNORMAL = X Normal
ZNORMAL = Z Normal
YZSHEAR = Y-Z Shear

MAXPRINC = Max Principal


VONMISES = von Mises
TRESCA = Tresca
SGMAXSHR = Signed Max Shear
YNORMAL = Y Normal
XYSHEAR = X-Y Shear
ZXSHEAR = Z-X Shear)

The sign on the Signed von Mises, Signed Tresca, Signed Max. Shear is taken
from the sign of the Abs. Max. Principal value.
For Stress Life, combined stress value is used; For Strain Life, combined strain
value is used.
For Strain Life, shear strain components are engineering shear strain (two times
tensor shear strain).
For brittle materials, "Absolute maximum principle" is recommended.
For ductile materials, "Signed von Mises" is recommended.
Correction

Mean stress correction method. See comments 5, 6, 7 and 8.


For Type = SN, valid options are:
Default = GOODMAN (NONE, GOODMAN, GERBER, GERBER2, SODERBE)
For Type = EN, valid options are:
Default = SWT (NONE, MORROW, MORROW2, SWT = Smith-Watson-Topper)

StressUnit

FE analysis Stress Tensor Unit. The Unit is necessary because the S-N/E-N
curve (MATFAT card) might be defined in different unit, and FEA stress needs
to be converted before looking up the fatigue life for a given stress level on the
S-N curve. See comment 10.
Default = MPA (MPA, PA, PSI, KSI)

Plasticity

This parameter is only applicable for Type = EN.


For Type = SN, it is not used.
For Type = EN, valid options are:
Default = NEUBER (NONE, NEUBER)

RAINFLOW

The RAINFLOW flag indicates that parameters required for Rainflow counting are
to follow. This flag and its related parameters will be used only when the Type
field is set to SN or EN.

Altair Engineering

OptiStruct 13.0 Reference Guide 1025


Proprietary Information of Altair Engineering

Field

Contents

RType

Rainflow data type. See comment 1.


Default = LOAD
(LOAD - Load-time history
STRESS - Stress-time history)

GateRel

Relative fraction of maximum gate range. The reference value is the maximum
range multiplied by GateRel, and used for gating out small disturbances or
"noise" in the time series.

CERTNTY

The CERTNTY flag indicates that parameters that define certainties in fatigue
analysis are to follow. This flag and the following parameter will be used only
when the Type field is set to SN or EN.

SurvCert

Certainty of survival based on the scatter of the S-N curve. See comment 4.
Default = 0.5 (0.0 < Real < 1.0)

FOS

The FOS flag indicates that the following parameters are for Factor of Safety
analysis (Type = FOS). This flag and following parameter will be used only when
the Type field is set to FOS.

FOSType

This field can be used to select the Factor of safety analysis type.
Default = DANGVAN

Comments
1.

RType = Load is valid when there is only one static load case defined in an event. If the
event contains multiple static load cases, then RType will automatically be set to STRESS
because there will be stress super-positioning among different load cases; doing rainflow
counting on load-time history could not deal with it.

2.

When RType = Load, load-time history will be cycle counted using the rainflow cycle
counting method. The cycle counting results (load Ranges and Means) will be scaled by
combined FEA stress. Doing rainflow counting on load-time is much faster than doing it
on stress-time (RType=Stress), especially when the load-time history is complex and
contains a large number of time points, but it is less accurate.

3.

When RType = Stress, stress-time history will be cycle counted using the rainflow cycle
counting method. The stress-time history has the same length as load-time, while each
point of the stress time is the combined stress value where the stress tensor is FEA
stress scaled by y point value of the corresponding load-time history.

1026 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

Certainty of Survival is based on the scatter of the S-N / E-N curve. It is used to modify
the S-N / E-N curve according to the standard error parameter (SE) defined in fatigue
property of material card (MATFAT card). A higher reliability level requires a larger
certainty of survival.

5.

When fatigue optimization is performed, EN method with SWT mean stress correction is
changed to EN method with Morrow mean stress correction automatically.

6.

Correction=GERBER2 improves the GERBER method by ignoring the effect of negative mean
stress.

7.

Correction=MORROW2 improves the MORROW method by ignoring the effect of negative


mean stress.

8.

Correction=SODERBE is slightly different from GOODMAN, the mean stress is normalized by


yield stress instead of ultimate tensile stress.
Se = Sa / (1 - Sm / Sy )
Where, Se is equivalent stress amplitude, Sa is stress amplitude, Sm is mean stress, and
Sy is yield stress.

9.

The STRESS, RAINFLOW and CERTNTY continuation lines are ignored in a factor of
safety analysis (Type=FOS).

10. If UNITS=# or DTI UNITS is present, the default value of StressUnit should be determined
by UNITS=# or DTI UNITS. If UNITS=# and DTI UNITS are absent, the default value of
StressUnit is MPA. If UNITS=# or DTI UNITS is present, and StressUnit is also specified,
but they are not consistent, an error will be issued.
11. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1027


Proprietary Information of Altair Engineering

FATSEQ
Bulk Data Entry
FATSEQ Load Sequence Definition for Fatigue Analysis
Description
This bulk data entry can be used to define a loading sequence for a Fatigue Analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

FATSEQ

ID

FID1

N1

FID2

N2

FID3

N3

FID4

N4

FID5

N5

(10)

Field

Contents

ID

Each FATSEQ card must have a unique ID. FATSEQ Subcase Information entry
may reference this identifier. Alternatively this ID may be referenced by other
FATSEQ definitions.
No default (Integer > 0)

FID#

Identification number of FATSEQ or FATEVNT entry (see Comment 3)


No default (Integer > 0)

N#

Number of times this loading sequence or event is repeated (see Comment 4).
Default = 1 (Integer > 0)

Comments
1.

Identification numbers of FATSEQ and FATEVNT entries share the same ID pool.

2.

Repeat number (N#) has no effect on the results of a Factor of Safety (FOS) analysis.

3.

A fatigue subcase should reference the same subcase types through FATSEQ and
FATEVNT entries (for example, either static subcases or transient subcases can be
referenced, but not both). Referencing a combination of subcase types is not allowed.

4.

This card is represented as a loadcollector in HyperMesh.

1028 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FLDATA
Bulk Data Entry
FLDATA User-defined Forming Limit Curve for One-Step Stamping Simulation
Description
Defines a forming limit curve as a table of minor and major strain values in a one-step
stamping simulation.
Format
(1)

(2)

(3)

(4)

FLDATA

FLDID

Ei1

Ei2

(5)

(6)

(7)

(8)

(9)

(10)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

FLDATA

-.194

.284

FLDATA

-.0.89

.269

FLDATA

FLDATA

.319

.319

Field
FLDID

(5)

(6)

(7)

Contents
Blank holder identification number.
No default (Integer > 0)

Ei1

Minor strain value.


No default (Real)

Ei2

Major strain value


No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1029


Proprietary Information of Altair Engineering

Comments
1.

This entry is only valid with an @HyperForm statement in the first line of the input file.

1030 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FORCE
Bulk Data Entry
FORCE Point Force
Description
Defines a static force at a grid point by specifying a vector. It can also be used to define the
EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk
data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

FORC E

SID

C ID

N1

N2

N3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

FORC E

2.9

0.0

1.0

0.0

Field

Contents

SID

Load set identification number.

(9)

(10)

(Integer > 0)
G

Grid point identification number.


(Integer > 0 or <PartName.number>) See comment 3.

CID

Coordinate system identification number.


Default = 0 (Integer > 0, or blank)

Scale factor.

Altair Engineering

OptiStruct 13.0 Reference Guide 1031


Proprietary Information of Altair Engineering

Field

Contents
(Real)

N1,N2,N3

Components of vector measured in coordinate system defined by CID.


(Real; must have at least one non-zero component)

Comments
1.

The static force applied to grid point G is given by

where,

is the vector defined in fields 6, 7, and 8.

2.

A CID of zero or blank references the basic coordinate system.

3.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on FORCE entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN Bulk Data Entry in the model). number is the identification number of a
referenced local entry in the part PartName. See Parts and Instances in the Users
Guide for detailed information on the use of fully qualified references.

4.

This card is represented as a force load in HyperMesh.

1032 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FORCE1
Bulk Data Entry
FORCE1 Static Force, Alternate Form 1
Description
Used to define a static force by specification of a value and two grid points that determine
the direction. It can also be used to define the EXCITEID field (Amplitude A) of dynamic
loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

FORC E1

SID

G1

G2

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

FORC E1

13

-2.93

16

13

Field

Contents

SID

Load set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
G

Grid point identification number.


(Integer > 0)

Value of force.
(Real)

G1,G2

Grid point identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide 1033


Proprietary Information of Altair Engineering

Comments
1.

The static force applied to grid point G is

where,
2.

is a unit vector parallel to a vector from G1 to G2.

This card is represented as a force load in HyperMesh

1034 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FORCE2
Bulk Data Entry
FORCE2 Static Force, Alternate Form 2
Description
Used to define a static force by specification of a value and four grid points that determine
the direction. It can also be used to define the EXCITEID field (Amplitude A) of dynamic
loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

FORC E2

SID

G1

G2

G3

G4

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

FORC E2

13

-2.93

16

13

18

19

Field

Contents

SID

Load set identification number.

(9)

(10)

(Integer > 0)
G

Loaded Grid point identification number.


(Integer > 0)

Value of force.
(Real)

Gi

Grid point identification numbers.


(Integer > 0; G1 and G2 may not be coincident; G3 and G4 cannot be
coincident.)

Altair Engineering

OptiStruct 13.0 Reference Guide 1035


Proprietary Information of Altair Engineering

Comments
1.

The static force applied to grid point G is

where, is a unit vector parallel to a vector calculated by the cross product of vectors
from G1 to G2 and G3 to G4.
2.

This card is represented as a force load in HyperMesh

1036 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQ
Bulk Data Entry
FREQ Frequency List
Description
Defines a set of frequencies to be used in the solution of frequency response problems.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

FREQ

SID

F1

F2

F3

F4

F5

F6

F7

F8

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

FREQ

7.0

12.56

13.99

23.4

23.34

Field

Contents

SID

Identification number.

(8)

(9)

(10)

No default (Integer > 0)


F#

Frequency value.
No default (Real > 0.0)

Comments
1.

FREQ entries must be selected with the I/O Options or Subcase Information command
FREQUENCY = SID.

2.

The units for F# are cycles per unit time.

Altair Engineering

OptiStruct 13.0 Reference Guide 1037


Proprietary Information of Altair Engineering

3.

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter with a default of 10 -5 * fMAX , and fMIN are the maximum
and minimum excitation frequencies of the combined FREQi entries.
4.

This card is represented as a loadcollector in HyperMesh.

1038 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQ1
Bulk Data Entry
FREQ1 Frequency List, Alternate Form 1
Description
Defines a set of frequencies to be used in the solution of frequency response problems by
specification of a starting frequency, frequency increment, and the number of increments
desired.
Format
(1)

(2)

(3)

(4)

(5)

(6)

FREQ1

SID

F1

DF

NDF

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

FREQ1

2.9

0.5

13

Field

Contents

SID

Identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


F1

First frequency in set.


No default (Real > 0)

DF

Frequency increment.
No default (Real > 0.0)

NDF

Number of frequency increments.


Default = 1 (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1039


Proprietary Information of Altair Engineering

Comments
1.

FREQ1 entries must be selected with the I/O Options or Subcase Information command
FREQUENCY = SID.

2.

The units for F1 and DF are cycles per unit time.

3.

The frequencies defined by this entry are given by


where i = 1 to (NDF + 1).

4.

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter with a default of 10 -5 * fMAX , and

are the maximum

and minimum excitation frequencies of the combined FREQi entries.


5.

This card is represented as a loadcollector in HyperMesh.

1040 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQ2
Bulk Data Entry
FREQ2 Frequency List, Alternate Form 2
Description
Defines a set of frequencies to be used in the solution of frequency response problems by
specification of a starting frequency, final frequency, and the number of logarithmic
increments desired.
Format
(1)

(2)

(3)

(4)

(5)

FREQ2

SID

F1

F2

NF

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

FREQ2

1.0

8.0

Field

Contents

SID

Identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


F1

First frequency in set.


No default (Real > 0.0)

F2

Last frequency in set.


No default (Real > 0.0, F2 > F1)

NF

Number of logarithmic intervals.


Default = 1 (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1041


Proprietary Information of Altair Engineering

Comments
1.

FREQ2 entries must be selected with the I/O Options or Subcase Information command
FREQUENCY = SID.

2.

The units for F1 and F2 are cycles per unit time.

3.

The frequencies defined by this entry are given by

where,
4.

and i = 1, 2, , (NF + 1).

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter with a default of 10 -5 * fMAX , and

are the maximum

and minimum excitation frequencies of the combined FREQi entries.


5.

This card is represented as a loadcollector in HyperMesh.

1042 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQ3
Bulk Data Entry
FREQ3 Frequency List, Alternate Form 3
Description
Defines a set of frequencies for the modal method of frequency response analysis by
specifying the number of frequencies between modal frequencies.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

FREQ3

SID

F1

F2

TYPE

NEF

C LUSTER

(9)

(10)

Example

Define a set of frequencies such that there will be 10 frequencies between each mode,
within the frequency range 20 to 200, plus 10 frequencies between 20 and the lowest
mode in the range, plus 10 frequencies between the highest mode in the range and 200.
(1)

(2)

(3)

(4)

(5)

(6)

(7)

FREQ3

20.0

200.0

LINEAR

10

2.0

Field

Contents

SID

Set identification number.

(8)

(9)

(10)

No default (Integer > 0)


F1

Lower bound of modal frequency range in cycles per unit time.


No default (Real > 0.0 for TYPE = LINEAR ; Real > 0.0 for TYPE = LOG)

F2

Upper bound of modal frequency range in cycles per unit time.


Default = F1 (Real > 0.0, F2 > F1)

Altair Engineering

OptiStruct 13.0 Reference Guide 1043


Proprietary Information of Altair Engineering

Field

Contents

TYPE

Specifies linear or logarithmic interpolation between frequencies.


Default = "LINEAR" (LINEAR or LOG)

NEF

Number of excitation frequencies within each sub range including the end
points. The first sub range is between F1 and the first modal frequency
within the bounds. Intermediate sub ranges exist between each mode
calculated within the bounds. The last sub range is between the last
modal frequency within the bounds and F2.
Default = 10 (Integer > 1)

CLUSTER

Specifies cluster of the excitation frequency near the end points of the
range. See comment 5.
Default = 1.0 (Real > 0.0)

Comments
1.

FREQ3 applies only to the modal method of frequency response analysis.

2.

FREQ3 entries must be selected in the Subcase Information section with FREQUENCY =
SID.

3.

Since the forcing frequencies are near structural resonances, it is important that some
amount of damping be specified.

4.

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter, with a default of 10 -5 * fMAX and

are the maximum

and minimum excitation frequencies of the combined FREQi entries.


5.

CLUSTER is used to obtain better resolution near the modal frequencies where the
response variation is highest, in accordance with:

1044 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

where,

-1 + 2(k - 1)/(NEF - 1) is a parametric coordinate between -1 and 1.

excitation frequency number in the subrange (1,2,3,,NEF)

frequency at the lower limit of the sub range. (If TYPE is LOG, then this is
the logarithm of the frequency.)

frequency at the upper limit of the sub range. (If TYPE is LOG, then this is
the logarithm of the frequency.)

the k-th excitation frequency. (If TYPE is LOG, then this is the logarithm of
the frequency.)

CLUSTER > 1.0 provides closer spacing of excitation frequency towards the ends of the
frequency range, while values of less than 1.0 provide closer spacing towards the center
of the frequency range.
For example, if the frequency range is between 10 and 20, NEF = 11, TYPE = "LINEAR";
then, the excitation frequencies for various values of CLUSTER would be as shown in the
table below.
CLUSTER
Excitation
Frequency
Number

0.25

0.50

1.0

2.0

4.0

Excitation Frequencies in Hertz


1

-1.0

10.00

10.0

10.0

10.0

10.0

-0.8

12.95

11.8

11.0

10.53

10.27

-0.6

14.35

13.2

12.0

11.13

10.60

-0.4

14.87

14.2

13.0

11.84

11.02

-0.2

14.99

14.8

14.0

12.76

11.66

0.0

15.00

15.0

15.0

15.00

15.00

0.2

15.01

15.2

16.0

17.24

18.34

0.4

15.13

15.8

17.0

18.16

18.98

0.6

15.65

16.8

18.0

18.87

19.40

Altair Engineering

OptiStruct 13.0 Reference Guide 1045


Proprietary Information of Altair Engineering

10

0.8

17.05

18.2

19.0

19.47

19.73

11

1.0

20.00

20.0

20.0

20.00

20.00

6.

In design optimization, the excitation frequencies are derived from the modal frequencies
computed at each design iteration.

7.

In modal analysis, solutions for modal degrees-of-freedom from rigid body modes at zero
excitation frequencies may be discarded. Solutions for non-zero modes are retained.

8.

This card is represented as a loadcollector in HyperMesh.

1046 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FREQ4
Bulk Data Entry
FREQ4 Frequency List, Alternate Form 4
Description
Defines a set of frequencies for the modal method of frequency response analysis by
specifying the amount of "spread" around each modal frequency and the number of equally
spaced frequencies within the spread.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

FREQ4

SID

F1

F2

FSPD

NFM

(8)

(9)

(10)

Example

Define a set of frequencies such that there will be 21 equally spaced frequencies across a
frequency band of
and 200.

to

for each modal frequency that occurs between 20

(1)

(2)

(3)

(4)

(5)

(6)

FREQ4

20.0

200.0

0.30

21

Field

Contents

SID

Set identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


F1

Lower bound of modal frequency range in cycles per unit time.


Default = 0.0 (Real > 0.0)

F2

Upper bound of frequency range in cycles per unit time.


Default = 1.0E20 (Real > 0.0, F2 > F1)

Altair Engineering

OptiStruct 13.0 Reference Guide 1047


Proprietary Information of Altair Engineering

Field

Contents

FSPD

Frequency spread, +/- the fractional amount specified for each mode
which occurs in the frequency range F1 to F2.
Default = 0.10 (1.0 > Real > 0.0)

NFM

Number of evenly spaced frequencies per "spread" mode.


Default = 3 (Integer > 0; If NFM is even, NFM + 1 will be used)

Comments
1.

FREQ4 applies only to the modal method of frequency response analysis.

2.

FREQ4 entries must be selected in the Subcase Information section with FREQUENCY =
SID.

3.

There will be NFM excitation frequencies between


and
, for
each modal frequency in the range F1 to F2. If this computation results in excitation
frequencies less than F1 and greater than F2, those computed excitation frequencies are
ignored.

4.

Excitation frequencies may be based on modal frequencies that are not within the range
(F1 and F2) as long as the calculated excitation frequencies are within the range.
Similarly, an excitation frequency calculated based on natural frequencies within the
range (F1 through F2) may be excluded if it falls outside the range.

5.

The frequency spread can be used also to define the half-power bandwidth. The halfpower bandwidth is given by
, where,
is the damping ratio. Therefore, if FSPD
is specified equal to the damping ratio for the mode, NFM specifies the number of
excitation frequencies within the half-power bandwidth.

1048 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

Since the forcing frequencies are near structural resonances, it is important that some
amount of damping be specified.

7.

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter, with a default of 10-5. The values


and
the maximum and minimum excitation frequencies of the combined FREQi entries.

are

8.

In design optimization, the excitation frequencies are derived from the modal frequencies
computed at each design iteration.

9.

In modal analysis, solutions for modal degrees-of-freedom from rigid body modes at zero
excitation frequencies may be discarded. Solutions for non-zero modes are retained.

10. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1049


Proprietary Information of Altair Engineering

FREQ5
Bulk Data Entry
FREQ5 Frequency List, Alternate Form 5
Description
Defines a set of frequencies for the modal method of frequency response analysis by
specification of a frequency range and fractions of the natural frequencies within that range.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

FREQ5

SID

F1

F2

FR1

FR2

FR3

FR4

FR5

FR6

FR7

etc.

(10)

Example

Define a set of frequencies such that the list of frequencies will be 0.6, 0.8, 0.9, 0.95, 1.0,
1.05, 1.1, and 1.2 times each modal frequency between 20 and 200.
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

FREQ5

20.0

200.0

1.0

0.6

0.8

0.9

0.95

1.05

1.1

1.2

Field

Contents

SID

Set identification number.

(10)

No default (Integer > 0)


F1

Lower bound of modal frequency range in cycles per unit time.


Default = 0.0 (Real > 0.0)

1050 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

F2

Upper bound of frequency range in cycles per unit time.


Default = 1.0E20 (Real > 0.0, F2 > F1)

FRi

Fractions of the natural frequencies in the range F1 to F2.


No default (Real > 0.0)

Comments
1.

FREQ5 applies only to the modal method frequency response analysis.

2.

FREQ5 entries must be selected in the Subcase Information section with FREQUENCY =
SID.

3.

The frequencies defined by this entry are given by


where,

are the modal frequencies in the range F1 through F2.

If this computation results in excitation frequencies less than F1 and greater than F2,
those computed excitation frequencies are ignored.
4.

Excitation frequencies may be based on natural frequencies that are not within the range
(F1 and F2) as long as the calculated excitation frequencies are within the range.

5.

Since the forcing frequencies are near structural resonances, it is important that some
amount of damping be specified.

6.

All FREQi entries with the same set identification numbers will be used. Duplicate
frequencies will be ignored.

and

are considered duplicated if:

where, DFREQ is a user parameter, with a default of 10-5. The values


and
the maximum and minimum excitation frequencies of the combined FREQi entries.

are

7.

In design optimization, the excitation frequencies are derived from the modal frequencies
computed at each design iteration.

8.

In modal analysis, solutions for modal degrees-of-freedom from rigid body modes at zero
excitation frequencies may be discarded. Solutions for non-zero modes are retained.

9.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1051


Proprietary Information of Altair Engineering

GAPPRM
Bulk Data Entry
GAPPRM Parameters for Gap Element Connectivity and Configuration Checks
Description
Defines parameters that control connectivity and configuration checks for gap elements (CGAP
and CGAPG). Most of these parameters also affect contact elements that are automatically
created on CONTACT interfaces see individual descriptions for details.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

GAPPRM

PARAM1

VAL1

PARAM2

VAL2

PARAM3

VAL3

PARAM4

VAL4

PARAM5

VAL5

etc.

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

GAPPRM

C KGPDIR

-1

PRTSW

C HKRUN

Field

Contents

PARAM#

Name of parameter.

VAL#

Value of parameter.

(8)

(9)

(10)

While textual values are recommended for clarity, their integer equivalents will also be read.
The available parameters and their values are listed below (click the parameter name for
parameter descriptions).

Parameter

Value

1052 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHKRN

NO, 0, YES, or 1
Default = NO

CKGPDIR

ERR, 2, WARN, 1, NO, 0, REV, or 3


Default = ERR

ERRMSG

SHORT, 1, FULL, or 2
Default = SHORT

GAPCMPL

NO, 0, YES, 1
Default = YES

GAPGPRJ

NORM, 1, SHORT, or 2
Default = SHORT

GAPOFFS

GPCOINC

YES, NO
Default = YES
<Real>
Defaults
For GAP elements: 1.0e-04
For CONTACT elements: Calculated
automatically based on element size on the
master face.

HMGAPST

NO, 0 YES, 1
Default = NO

PRTSW

NO, 0, YES, 1
Default = NO

Comments
1.

The GAPPRM entry changes the default settings of control parameters for the gap
elements connectivity and checks for configuration errors. None of the parameters of this
entry are required.

2.

The gap alignment check controlled by the default value of CKGPDIR = ERR applies
correctly to the most typical situations wherein there is an initial opening between bodies
A and B, and the gap element is used to enforce non-penetration condition. For cases of
overlapping meshes (combined with a prescribed coordinate system), the REV value is
appropriate it allows both aligned and reversed gap directions (respective to the gap
axis defined by the prescribed system).

3.

This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1053


Proprietary Information of Altair Engineering

GAPPRM, CHKRN
Parameter
CHKRN

Values

Description

NO, 0, YES, or 1
Default = NO

Stop the run after the gap element checks are


completed.
If NO or 0, OptiStruct will run to completion unless
other errors are present.
If YES or 1, OptiStruct will stop after gap and
contact elements have been checked.

1054 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GAPPRM, CKGPDIR
Parameter
CKGPDIR

Values

Description

ERR, 2, WARN, 1,
NO, 0, REV, or 3

Controls the checking of gap element alignment in


case of prescribed coordinate system CID.

Default = ERR

If ERR or 2, then all non-zero length gap elements


that have a prescribed coordinate system are
checked for misalignment of the gap prescribed axis
(x-axis of the prescribed coordinate system) with
the vector GA->B. Angles larger than 30 degrees
produce warnings, angles larger than 60 degrees
produce errors.
If WARN or 1, same as ERR or 2 with the exception
that only warnings are issued.
If NO or 0, then no gap CID direction checks are
performed.
If REV or 3, then orientations of the vector GA->B
that are generally opposite to the prescribed axis
are also accepted. The tolerance levels are the
same as for the default case, except that they are
measured from either 0 or 180 degrees reference
angle.

Altair Engineering

OptiStruct 13.0 Reference Guide 1055


Proprietary Information of Altair Engineering

GAPPRM, ERRMSG
Parameter
ERRMSG

Values

Description

SHORT, 1,
FULL, or 2

Defines the maximum number of error messages printed


for gap and contact elements.

Default = SHORT

If SHORT or 1, then up to 10 error messages are printed


along with a summary of the total number of errors.
If FULL or 2, then all gap and contact element error
messages are printed. Additional diagnostic information
for elements with errors is also printed to the .out file.

1056 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GAPPRM, GAPCMPL
Parameter
GAPCMPL

Values

Description

NO, 0, YES, or 1
Default = YES

This parameter can be used to allow/disallow the


inclusion of gap and contact compliance in the
calculation of global compliance.
If YES or 1, then gap/contact compliances will be
included in the calculation of global compliance.
If NO or 0, then gap/contact compliances will not be
included in the calculation of global compliance.
Note:
An example situation where the GAPCMPL parameter may
be used is described as follows:
In some cases, gap/contact elements may exist with
initial penetration (U0<0), these elements may produce
negative contributions to the global compliance. While
this is a legitimate situation (the gap/contact is releasing
elastic energy, rather than accumulating it) it may cause
the global compliance to be negative and thus make
optimization impossible. In such cases, the GAPCMPL
parameter can be used to turn off the contributions of
gap/contact elements to the compliance calculation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1057


Proprietary Information of Altair Engineering

GAPPRM, GAPGPRJ
Parameter
GAPGPRJ

Values

Description

NORM, 1, SHORT, or 2
Default = SHORT

For CGAPG and contact elements, controls how


the projection onto the obstacle element (or
node patch) is performed.
If NORM or 1, the projection of node GA (or
slave node for CONTACT) to the obstacle B is
performed along the normal to the surface of
the obstacle (a patch of nodes or an element
face). If such normal projection falls outside
the patch of nodes or element face (within 5%
tolerance), an error message is issued for GAPG
elements, while no contact element is created
on the CONTACT interface.
If SHORT or 2, the node GA (or slave node for
CONTACT) is projected onto the obstacle B
along the shortest distance. For cases where
the normal projection falls within the bounds of
the obstacle, this coincides with the NORM
option. For cases where the normal projection
falls outside the obstacle, this option will
choose the point on the obstacle that is
nearest to GA or slave node.

1058 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GAPPRM, GAPOFFS
Parameter

Values

Description

GAPOFFS

YES, NO, AUTO

If YES, frictional offset for gap and contact analysis is


active.

Default = AUTO

If NO, frictional offset for gap and contact analysis in


inactive.
If AUTO, frictional offset is turned off when the deck
contains gaps, contact with friction or stick conditions
and at least one nonlinear subcase. This affects both
linear and nonlinear subcases.
For more details, refer to the PGAP and PCONT
descriptions.

Altair Engineering

OptiStruct 13.0 Reference Guide 1059


Proprietary Information of Altair Engineering

GAPPRM, GPCOINC
Parameter
GPCOINC

Values

Description

<Real>
See the Note
for defaults

This parameter defines the distance below which the end


points of gap/contact elements (for example, the GA, GB
fields of the CGAP bulk data entry) are considered
coincident (as they may be too close to define the gap
direction accurately).
Note:
1.

Currently, for CGAP and CGAPG elements, the default


minimum distance is set at an absolute value of
1.0e-4. For CONTACT, it is calculated automatically
according to element size on the master face, in
which case it is automatically scaled if there is a
change in units.

2.

This parameter is automatically included in the


<filename>.contgap.fem file, which is an ASCII
format file generated when CONTPRM,CONTGAP,YES is
used.

1060 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GAPPRM, HMGAPST
Parameter
HMGAPST

Values

Description

NO, 0, YES, or 1
Default = NO

Create HyperMesh command file that defines sets


containing open and closed gaps for the initial set up and
for each nonlinear subcase. The file name is
<my_job>.hm.gapstat.cmf.
If NO or 0, then no file is produced.
GAPPRM,HMGAPST,YES can also be used to visualize the
status of internally created CONTACT elements. This
requires the additional command CONTPRM,CONTGAP,YES
it will create a file, <my_job>.contgap.fem, that
contains contact elements converted to CGAPG entities.
For correct visualization of their open/closed status in
HyperMesh, this file needs to be imported before running
the gap status command file,
<my_job>.HM.gapstat.cmf.

Altair Engineering

OptiStruct 13.0 Reference Guide 1061


Proprietary Information of Altair Engineering

GAPPRM, PRTSW
Parameter
PRTSW

Values

Description

NO, 0, YES, or 1

Print diagnostic output for gap elements.

Default = NO

If NO or 0, OptiStruct will not output diagnostic


information.
If YES or 1, OptiStruct will print diagnostic information to
the .out file.

1062 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GENEL
Bulk Data Entry
GENEL General Finite Element
Description
Defines the stiffness or flexibility of a general element connected to an arbitrary number of
grids.
Format
(1)

(2)

(3)

GENEL

EID

GI4

C I4

UD

(4)

(5)

(6)

(7)

(8)

(9)

(10)

GI1

C I1

GI2

C I2

GI3

C I3

GI5

C I5

-etc.-

GD1

C D1

GD2

C D2

GD3

C D3

GD4

C D4

GD5

C D5

-etc.-

K or
Z

KZ11

KZ12

KZ13

-etc.-

KZ21

KZ22

-etc.-

KZ31

KZ32

-etc.-

S11

S12

S13

-etc.-

S21

S22

-etc.-

S31

S32

-etc.-

Example 1

(1)

(2)

GENEL

537

1002

Altair Engineering

(3)

(4)

(5)

(6)

(7)

(8)

(9)

1001

1001

1001

1002

1002

(10)

OptiStruct 13.0 Reference Guide 1063


Proprietary Information of Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

5757.

-816.6

-43.1

-5757.

816.6

43.1

35479.3

-1151.

816.6

35479.3

1151.

6538.6

43.1

1151.

-6538.6

5757.

-816.6

-43.1

35479.3

-1151.

6538.6

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

GENEL

4001

1073

1073

1073

1073

1073

1074

1074

1074

1074

1074

(10)

Example 2

1073

UD

1074

.592-6

.39-6

-.39-6

(10)

.592-6

.1-9

.319-6

.319-6

.1-9

Example 3

(1)

(2)

GENEL

435

17

(3)

(4)

(5)

(6)

(7)

(8)

(9)

11

23

72

(10)

1064 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

1.7

2.3

3.6

4.4

5.2

6.8

7.1

.1

.2

.3

.4

.5

.6

.7

12

47

(10)

8.9

.8

UD

Field

Contents

EID

Unique element identification number.


No default (Integer > 0)

GIi/CIi

Grid (or scalar point) and component identification numbers ordered


according to stiffness or flexibility values specified after KZmn. For scalar
points, CIi is zero.
No default (GIi is integer > 0 and CIi is integer > 0).

UD

Flag indicating that the subsequent fields and continuation entries contain
values for GDj/CDj until K, Z, or S is specified in field 2 or it is the
end of the entry.
No default (Character)

GDj/CDj

Grid (or scalar point) and component identification numbers ordered


according to the columns in the S matrix.
No default (GDj is integer > 0 and CDj is integer > 0).

K or Z

Flag indicating that the next fields and continuation entries contain
stiffness values until UD or S is specified in field 2 or it is the end of
the entry.
No default (Character)

KZmn

Stiffness or flexibility matrix for degrees-of-freedom in GIi/CIi where m is

Altair Engineering

OptiStruct 13.0 Reference Guide 1065


Proprietary Information of Altair Engineering

Field

Contents
the row number and n is the column number. Only the lower triangular
terms in the matrix need to be specified. Zero values must be specified
as blank or 0.0.
Default = 0.0 (Real)

Flag indicating that the subsequent fields and continuation entries contain
values for the S matrix.
No default (Character)

Sij

S matrix values where i corresponds to GIi/CIi list and j corresponds


to GDj/CDj list until K, Z, or UD is specified in field 2 or it is the end
of the entry. All the terms in the matrix must be specified and zero
values must be specified as blank or 0.0.
Default = 0.0 (Real)

Comments
1.

GIi/CIi and KZmn are required inputs. Either K or Z must be specified, but not both.

2.

UD, K, Z, and S, may be specified in any order as demonstrated in the third


example.

3.

UD and S are optional inputs. S defines the motion between the GIi/CIi and GDj/CDj
degrees-of-freedom according to:

But if S is specified then GDj/CDj must also be specified. If S is not specified then
GDj/CDj may contain six and only six degrees of freedom and they cannot refer to
SPOINTs.
4.

If only K or Z is input without UD then it is recommended that the resulting stiffness


represents the unsupported element, containing all of the rigid body modes. If not, then
the UD option allows for the reintroduction of the rigid body modes with S which is
provided by you or computed internally.
a) If K and UD are specified then the program will form the complete stiffness as
defined by the following equation:

Where the K matrix is formed from the KZmn values and the S matrix is formed from the
Sij values or computed automatically.

1066 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

b) If Z and UD are specified then the program will form the complete stiffness as
defined by the following equation:

Where the Z matrix is formed from the KZmn values and the S matrix is formed from the
Sij values or computed automatically. Z must be nonsingular.
5.

PARAM,CK3 may be used to scale the stiffness produced by all GENEL elements.

6.

All lower triangular values in K and Z and all values in S have to be accounted for in the
input. Zero values may be specified as 0.0 or be left blank, however if all entries in any
continuation line are zero, then at least one visible character must appear on this line (it
can be 0.0 in any field or the plus sign (+) in the first column) because blank lines are
treated as comment. Unused fields (after the last matrix entry) must be blank.

7.

General elements are ignored in heat transfer analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide 1067


Proprietary Information of Altair Engineering

GRAV
Bulk Data Entry
GRAV Gravity Vector
Description
Defines the gravity vectors for use in determining gravity loading for the structural model. It
can also be used to define the EXCITEID field (Amplitude A) of dynamic loads in RLOAD1,
RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

GRAV

SID

C ID

N1

N2

N3

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

32.2

0.0

0.0

-1.0

GRAV

Field

Contents

SID

Set identification number.

(8)

(9)

(10)

(Integer > 0)
CID

Coordinate system identification number.


(Integer > 0)

Gravity vector scale factor.

N1,N2, N3 Gravity vector components.


(Real; at least one non-zero component)

1068 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The gravity vector is defined by g = G(N1, N2, N3). The direction of G is the direction of
free fall. N1, N2, and N3 are in coordinate system CID.

2.

A CID of zero references the basic coordinate system.

3.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1069


Proprietary Information of Altair Engineering

GRDSET
Bulk Data Entry
GRDSET Grid Point Default
Description
Defines default options for fields 3, 7, and 8 of all GRID entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

GRDSET

blank

CP

blank

blank

blank

CD

PS

blank

Example

(1)

(2)

GRDSET

(3)

(4)

16

(5)

(6)

(7)

(8)

32

3456

(9)

Field

Contents

CP

Identification number of coordinate system in which the location of the grid


point is defined.

(10)

(Integer > 0 or blank)


CD

Identification number of coordinate system in which displacements are


measured at grid point.
(Integer > 0 or blank)

PS

Permanent single-point constraints associated with grid point (any of the


digits 1-6 with no embedded blanks).
(Integer > 0 or blank)

1070 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The contents of fields 3, 7, or 8 of this entry are assumed for the corresponding fields of
any GRID entry whose field 3, 7, and 8 are blank. If any of these fields on the GRID entry
are blank, the default option defined by this entry occurs for that field. If no permanent
single-point constraints are desired or one of the coordinate systems is basic, the default
may be overridden on the GRID entry by entering zero in the corresponding field. Only
one GRDSET entry may appear in the bulk data section.

2.

The primary purpose of this entry is to minimize the burden of preparing data for problems
with a large amount of repetition (for example, two-dimensional pinned-joint problems).

3.

At least one of the entries CP, CD, or PS must be non-zero.

4.

This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1071


Proprietary Information of Altair Engineering

GRID
Bulk Data Entry
GRID Grid Point
Description
Defines the location of a geometric grid point of the structural model, the directions of its
displacement, and its permanent single-point constraints.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

GRID

ID

CP

X1

X2

X3

CD

PS

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

GRID

1.0

-2.0

3.0

Field

Contents

ID

Unique grid point identification number.

(7)

(8)

(9)

(10)

316

(Integer > 0)
CP

Identification number of coordinate system in which the location of the grid


point is defined.
(Integer > 0 or blank)

X1,X2,X3

Location of the grid point in coordinate system CP.


(Real)

CD

Identification number of coordinate system in which the displacements,


degrees-of-freedom, constraints, and solution vectors are defined at grid
point.

1072 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Integer > -1 or blank)

PS

Permanent single-point constraints associated with grid point. Up to six


unique digits may be placed in the field with no imbedded blanks.
(Integer > 0 or blank)

See the GRDSET entry for default options for fields 3, 7, and 8.
Comments
1.

All grid point identification numbers must be unique with respect to all other structural grid
and scalar points. A duplicate identification number is only allowed if all fields on the
duplicated entries are exactly the same, unless PARAM,DUPTOL is used. PARAM,DUPTOL
can be used to set a tolerance that will allow a GRID with same ID, CP, CD, and PS to
have slightly different coordinates. Refer to Guidelines for Bulk Data Entries.

2.

The meaning of X1, X2, and X3 depends on the type of coordinate system, CP, as
follows: (see CORDI entry descriptions).
Type

X1

X2

X3

Rectangular

Cylindrical

q(degrees)

Spherical

q(degrees) f(degrees)

3.

The collection of all CD coordinate systems defined on all GRID entries is called the Global
Coordinate System. All degrees-of-freedom, constraints, and solution vectors are
expressed in the Global Coordinate System.

4.

If CD = -1, then this defines a fluid grid point in the coupled fluid-structural analysis. This
type of point may only connect the CHEXA, CPENTA, and CTETRA elements to defined
fluid elements.

5.

If CP, PS, or CD is blank, information from the GRDSET data will be used. If CP or CD
contains a zero, the basic coordinate system will be used. If PS contains a zero, single
point constraints on the GRDSET data are ignored.

6.

Input data replication is available for the GRID data. This can be used to generate
additional GRID data, based on incrementing the GRID ID and coordinate locations.

7.

This card is represented as a node in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1073


Proprietary Information of Altair Engineering

GRIDS
Bulk Data Entry
GRIDS Section Grid Point
Description
Defines a grid point on the y-z plane, using cartesian coordinates, for use in the definition of
arbitrary beam cross-sections.
Format
(1)

(2)

(3)

(4)

GRIDS

ID

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

GRIDS

101

1.1

2.1

Field

Contents

ID

Identification number.

(5)

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


Y

Y location of the grid point.


No default (Real)

Z location of the grid point.


No default (Real)

Comments
1.

All grid point identification numbers within a section definition must be unique with respect
to all other grid point identification numbers within the same section definition.

2.

This entry is only valid when it appears between the BEGIN and END statements.

1074 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GROUND
Bulk Data Entry
GROUND Ground Body Definition for Multi-body Simulation
Description
Defines a ground body out of a list of finite element properties, elements, and grid points.
Format
(1)

(2)

GROUND

BID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

TYPE2

ID1

ID2

TYPE#

(10)

BODY_NAME

TYPE1

Example 1

(1)

(2)

GROUND

(3)

(4)

(5)

(7)

(8)

(9)

(10)

SUPPORTING_BEAM

PSHELL

23

21

PBEAM

59

48

C ONM2

2345

GRID

400

401

402

Altair Engineering

(6)

OptiStruct 13.0 Reference Guide 1075


Proprietary Information of Altair Engineering

Example 2

(1)

(2)

(3)

GROUND

ANC HOR

PBAR

10

(4)

(5)

(6)

(7)

(8)

(9)

11

13

15

22

99

88

(10)

44

Field

Contents

BID

Unique body identification number.


No default (Integer > 0)

BODY_NAME

Unique body name. The body name for this PRBODY.


Default = OUTFILE_body_<BID> (Character string)

TYPE#

Flag indicating that the following list of IDs refer to entities of this
type. All property definitions; CELAS2, CONM2, PLTOEL, RBE2, RBE3,
RBAR, RROD, and GRID are valid types for this field.
No default (PBAR, PBARL, PBEAM, PBEAML, PBUSH, PCOMP, PDAMP,
PELAS, PGAP, PROD, PSHEAR, PSHELL, PSOLID, PVISC, PWELD,
CELAS2, CONM2, PLOTEL, RBE2, RBE3, RBAR, RROD, GRID)

ID#

Identification numbers of entities of the preceding TYPE flag.


No default (Integer > 0)

Comments
1.

Any number of property definitions; CELAS2, CONM2, PLOTEL, RBAR, RBE2, RBE3, or RROD
elements or grid points can be given.

2.

At least one property definition, element, or grid point must be given.

3.

A property definition, CELAS2, CONM2, PLOTEL, RBE2, REB3, RBAR, or RROD element or
grid point can only belong to one ground or rigid or flexible body.

4.

The grid ID provided in the ground card is considered grounded.

5.

This card is represented as a group in HyperMesh.

1076 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

HYBDAMP
Bulk Data Entry
HYBDAMP Apply Hybrid Damping to the Residual Structure in a Direct or Transient
Frequency Response Analysis
Description
This bulk data entry defines the application of modal damping to the residual structure in a
direct or transient frequency response analysis.
Format
(1)

(2)

(3)

(4)

(5)

HYBDAMP

SID

METHOD

SDAMP

KDAMP

(6)

(7)

(8)

(9)

(10)

Field

Contents

HYBDAMP

Keyword for applying modal damping on a direct analysis

SID

Unique hybrid damping SID (Referred to by the HYBDAMP I/O section


data).

METHOD

Identification number of EIGRL/EIGRA data. Hybrid damping is applied on


the modes determined by the eigenvalue analysis.
No default (Integer > 0)

SDAMP

Identification number of TABDMP1 entry for modal damping.


No default (Integer > 0)

KDAMP

If KDAMP is set to -1/YES, modal damping is entered into the complex


stiffness matrix as material damping, instead of viscous damping. The
default is 1/NO to enter the damping as viscous damping.
Default = 1 (Integer)

Comments
1.

HYBDAMP SID can be set by the HYBDAMP I/O Options Entry in the I/O section of the input
data.

Altair Engineering

OptiStruct 13.0 Reference Guide 1077


Proprietary Information of Altair Engineering

2.

Hybrid damping can be defined as shown below:


If KDAMP is set to 1/NO (Default), then:

If KDAMP is set to -1/YES, then:

Where,
are the modes of the structure
[M] is the structural mass matrix
b(
g(

) are the modal damping values


) are equal to twice the critical damping ratios calculated from the TABDMP1 entry
is the natural frequency of mode

mi is the generalized mass of mode

1078 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

INCLUDE
I/O Options and Bulk Data Entry
This bulk data card is identical to the I/O options entry, INCLUDE.

Altair Engineering

OptiStruct 13.0 Reference Guide 1079


Proprietary Information of Altair Engineering

INSTNCE
Bulk Data Entry
INSTNCE Defines part location within the global part
Description
The INSTNCE bulk data entry can be used to define the location of a part in the global
structure. Each INSTNCE entry should reference a unique part name.
Format
(1)

(2)

(3)

(4)

INSTNC E

ID

name

NN

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

INSTNC E

C rankShaft

32

Field

Contents

ID

Set identification number.

(5)

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
name

This field specifies the unique name of a part that is to be attached to the
global part (see comment 2). It should match the name of one of the parts
defined using the BEGIN, FEMODEL, name entry.
(Character String)

NN

ID of a RELOC bulk data entry. This field defines the actual location of the part
in the final model via the RELOC entry.
Default = Blank (Integer > 0)

1080 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The full model consists of several parts, one part is designated as global and the rest of
the parts are attached to the global part using INSTNCE entries. The global part can have
an arbitrary name (it is identified by the presence of INSTNCE entries). A minimum of one
INSTNCE entry should always be present in the model.

2.

All INSTNCE entries should exist within a global part and no INSTNCE entry can reference
the name of a global part on the name field.

3.

Each INSTNCE entry should reference a different part name. However, not every part has
to be defined using an INSTNCE entry. Such parts are still contained within the full model
without any relocation.

4.

A global part can be moved to a different location, however, this is not recommended as
it may lead to inaccuracies in locating other parts.

Altair Engineering

OptiStruct 13.0 Reference Guide 1081


Proprietary Information of Altair Engineering

INVELB
Bulk Data Entry
INVELB Initial Velocity of a Body
Description
Defines initial velocity in a multi-body situation.
Format
(1)

(2)

(3)

(4)

INVELB

SID

BID

C ID

VX

VY

VZ

(5)

(6)

(7)

WX

WY

WZ

(8)

(9)

(10)

Example

(1)

(2)

(3)

INVELB

(4)

(5)

(6)

(7)

(8)

(9)

(10)

1000.0

Field

Contents

SID

Load set identification number.


(Integer > 0)

BID

Body identification number.


(Integer > 0)

CID

Reference coordinate system.


(Integer > 0)

1082 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

VX, VY, VZ

Translational velocities.
(Blank or Real)

WX, WY, WZ Rotational velocities.


(Blank or Real)
Comments
1.

Only one initial velocity per body can be defined in a load set.

2.

A CID of zero or blank references the basic coordinate system.

3.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1083


Proprietary Information of Altair Engineering

INVELJ
Bulk Data Entry
INVELJ Initial Velocity of a Joint
Description
Defines initial velocity of a joint in a multi-body situation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

INVELJ

SID

JID

JTYPE

VT

VR

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

INVELJ

REV

(5)

Field

Contents

SID

Load set identification number.

(6)

(7)

(8)

(9)

(10)

10.0

(Integer > 0)
JID

Joint identification number.


(Integer > 0)

JTYPE

Joint type.
Options = ("REV", "CYL", or "TRANS")
No default

VT

Translational velocity
If JTYPE = TRANS, VT must be real.

1084 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

VR

Rotational velocity
If JTYPE = REV, VR must be real.

Comments
1.

Only one initial velocity per joint can be defined in a load set.

2.

Initial velocities of joints defined by INVELJ will be overwritten by MOTNJ, MOTNJE, or


MOTNJC.

Altair Engineering

OptiStruct 13.0 Reference Guide 1085


Proprietary Information of Altair Engineering

JOINT
Bulk Data Entry
JOINT Joint Definition for Multi-body Solution Sequence
Description
Defines a joint.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

JOINT

JID

JTYPE

G1

G2

X3, G3

Y3

Z3

blank

X4, G4

Y4

Z4

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

JOINT

BALL

345

231

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

JOINT

UNIV

456

899

0.0

0.0

1.0

Example 2

399

Field

Contents

JID

Unique joint identification number.


(Integer > 0)

1086 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

JTYPE

Joint type
(BALL, FIX, REV, TRANS, CYL, UNIV, CV, PLANAR, INLINE, PERP, PARA,
INPLANE, or ORIENT).

G1, G2

Geometric grid point identification number. Used to identify the bodies


to be connected and, for many JTYPEs, the location of the joint.
(Integer > 0)

X3, Y3, Z3

First orientation vector of the joint.


(Real)

G3

Grid point identification number to optionally supply X3, Y3, Z3 in


conjunction with either G1 or G2 (depending on the JTYPE).
(Integer > 0)

X4, Y4, Z4

Second orientation vector of the joint.


(Real)

G4

Grid point identification number to optionally supply X4, Y4, Z4 in


conjunction with G2.
(Integer > 0)

Comments
1.

Joints are only valid in a multi-body solution sequence.

2.

G1 and G2 identify the bodies being joined and must, therefore, belong to different bodies.

3.

Definition of the different joint types:


Joint Type

Description

Ball

Fixed

Required
Fields

Joint Orientation

All translations are BALL


fixed; all rotations
are free.

G1, G2

G1 and G2 must
coincide.

All translations

G1, G2

G1 and G2 must

Altair Engineering

JTYPE

FIX

OptiStruct 13.0 Reference Guide 1087


Proprietary Information of Altair Engineering

Joint Type

Description

JTYPE

Required
Fields

Joint Orientation

and rotations are


fixed.
Revolute

Translational

Cylindrical

Universal

coincide.

Rotation about a
single selected
axis is free; other
rotations and
translations are
fixed.

REV

Translation along
a single selected
axis is free; other
translations and
rotations are
fixed.

TRANS

Translation along
and rotation
about a single
selected axis is
free; other
translations and
rotations are
fixed.

CYL

Rotations about
UNIV
two selected
perpendicular axes
are free;
translations and
other rotations
are fixed.

G1, G2,
and either
X3, Y3,
Z3 or G3

G1, G2,
and either
X3, Y3,
Z3 or G3

G1, G2,
and either
X3, Y3,
Z3 or G3

G1, G2,
and either
X3, Y3, Z3
or G3 and
either X4,
Y4, Z4 or
G4

Constant Vel Rotations about


CV
two selected axes
are equal and
opposite;

G1, G2,
and either
X3, Y3, Z3
or G3 and

G1 and G2 must
coincide.
The selected axis is
defined by the vector
X3, Y3, Z3 or
alternatively the vector
from G1 to G3.
G1 and G2 must be along
the joint axis.
The selected axis is
defined by the vector
X3, Y3, Z3 or
alternatively the vector
from G1 to G3.
G1 and G2 must be along
the joint axis.
The selected axis is
defined by the vector
X3, Y3, Z3 or
alternatively the vector
from G1 to G3.

G1 and G2 must
coincide.
The first selected (cross
pin) axis is defined by
the vector X3, Y3, Z3 or
alternatively the vector
from G1 to G3.
The second selected
(cross pin) axis is defined
by the vector X4, Y4, Z4
or alternatively the
vector from G2 to G4.
The selected axes must
be perpendicular.
G1 and G2 must coincide.
The first selected axis is
defined by the vector
X3, Y3, Z3 or

1088 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Joint Type

Description

JTYPE

Required
Fields

Joint Orientation

translations and
other rotations
are fixed.

either X4,
Y4, Z4 or
G4

Translations on a PLANAR
plane defined by a
selected normal
vector and the
rotation about
that normal
vector are free,
out-of-plane
translations and
rotations are
fixed.

G1, G2,
and either
X3, Y3,
Z3 or G3

Translation along INLINE


a single selected
axis and all
rotations are free;
other translations
are fixed.

G1, G2,
and either
X3, Y3,
Z3 or G3

Perpendicular Two perpendicular PERP


axes are selected
that are always to
remain
perpendicular.
Therefore,
rotations about
both selected
axes and all
translations are
free. Rotation
about the crossproduct of the
two selected
vectors is fixed.

G1,G2 and
either X3,
Y3, Z3 or
G3 and
either X4,
Y4, Z4 or
G4

Parallel Axes

G1,G2
and either
X3, Y3,

Planar

Inline

Two parallel axes


are selected that
are always to

Altair Engineering

PARA

alternatively the vector


from G1 to G3.
The second selected axis
is defined by the vector
X4, Y4, Z4 or
alternatively the vector
from G2 to G4.
G1 and G2 must be in the
joint plane.
The vector X3, Y3, Z3 or
the vector from G1 to G3
will define the normal to
the plane.

G1 and G2 must be along


the joint axis.
The selected axis is
defined by the vector
X3, Y3, Z3 or
alternatively the vector
from G2 to G3.
The first selected axis is
defined by the vector
X3, Y3, Z3 or
alternatively the vector
from G1 to G3.
The second selected axis
is defined by the vector
X4, Y4, Z4 or
alternatively the vector
from G2 to G4.
The selected vectors
must be perpendicular to
one another.

The first selected axis is


defined by the vector X3,
Y3, Z3 or alternatively
the vector from G1 to

OptiStruct 13.0 Reference Guide 1089


Proprietary Information of Altair Engineering

Joint Type

Inplane

Description

JTYPE

Required
Fields

remain parallel.
Therefore,
rotations about
the selected
parallel axes and
all translations are
free; other
rotations are
fixed.

Z3 or G3
and either
X4, Y4,
Z4 or G4

Two perpendicular INPLANE


vectors are
selected that
describe a plane.
Out-of-plane
translations are
fixed; all other
translations and
rotations are free.

G1,G2
and either
X3, Y3,
Z3 or G3
and either
X4, Y4,
Z4 or G4

Joint Orientation

Orient

4.

All rotations are


fixed; all
translations are
free.

ORIENT

G3.
The second selected axis
is defined by the vector
X4, Y4, Z4 or
alternatively the vector
from G2 to G4.
The selected vectors
must be parallel to one
another.
The first selected vector
is defined by X3, Y3, Z3
or alternatively the
vector from G2 to G3.
The second selected
vector is defined by X4,
Y4, Z4 or alternatively
the vector from G2 to
G4.
The selected vectors
must be perpendicular to
one another.

G1,G2

This card is represented as a joint element in HyperMesh.

1090 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

JOINTM
Bulk Data Entry
JOINTM Joint Definition for Multi-body Solution Sequence using Marker
Description
Defines a joint using two grids which have a marker card associated with them.
Format
(1)

(2)

(3)

(4)

(5)

JOINTM

JID

JTYPE

M1

M2

(6)

(7)

(8)

(9)

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

JOINTM

BALL

345

231

(1)

(2)

(3)

(4)

(5)

JOINTM

UNIV

456

899

(6)

(7)

(8)

(9)

(10)

(6)

(7)

(8)

(9)

(10)

Example 2

Field

Contents

JID

Unique joint identification number.


(Integer > 0)

JTYPE

Joint type
(BALL, FIX, REV, TRANS, CYL, UNIV, CV, PLANAR, INLINE, PERP, PARA,
INPLANE, or ORIENT)

Altair Engineering

OptiStruct 13.0 Reference Guide 1091


Proprietary Information of Altair Engineering

Field

Contents

M1, M2

Marker identification numbers.


(Integer > 0)

Comments
1.

Joints are only valid in a multi-body solution sequence.

2.

M1 and M2 must belong to different bodies and must have a marker card associated with
them.

3.

Definition of the different joint types:


Joint Type

JTYPE

Definition

Joint Orientation

Ball

BALL

M1, M2

M1, M2 must coincide.

Fixed

FIX

M1, M2

M1, M2 must coincide.

Revolute

REV

M1, M2

M1, M2 must coincide.


The joint axis will be along the
Z-axis of marker M1.

Translational

TRANS

M1, M2

M1, M2 must be along the joint


axis.
The joint axis will be along the
Z-axis of marker M1.

Cylindrical

CYL

M1, M2

M1, M2 must be along the joint


axis.

Universal

UNIV

M1, M2

M1, M2 must coincide.

Constant
Velocity

CV

M1, M2

M1, M2 must coincide.

Planar

PLANAR

M1, M2

M1, M2 must be in the joint


plane.

Inline

INLINE

M1, M2

Perpendicular

PERP

M1, M2

Parallel Axes

PARA

M1, M2

Inplane

INPLANE

M1, M2

1092 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Joint Type

JTYPE

Definition

Joint Orientation

Orient

ORIENT

M1, M2

No relative rotation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1093


Proprietary Information of Altair Engineering

LINE
Bulk Data Entry
LINE Line Definition
Description
Definition of a line.
Format
(1)

(2)

(3)

(4)

LINE

LINEID

EDGE

GA1

GB1

GA2

GB2

GA3

GB3

...

...

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

LINE

100

EDGE

33

34

34

35

35

36

(4)

(5)

(6)

(7)

(8)

1094 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

Alternate Format
In this format, line is represented as collection of 1-D, 2-D or 3-D elements.
(1)

(2)

(3)

LINE

LINEID

ELEDGE

EID1

EID2

EID9

(4)

(5)

(6)

(7)

(8)

(9)

EID3

EID4

EID5

EID6

EID7

EID8

(10)

-etc-

Alternate Format (SET)


In this format, a line is defined by a SET of elements. With this approach, the line is composed
of all the edges of all selected 1-D, 2-D or 3-D elements in the SET.
(1)

(2)

(3)

(4)

LINE

LINEID

SET

SID

(5)

(6)

(7)

Field

Contents

LINEID

Non-unique identification number of LINE.

(8)

(9)

(10)

No default (Integer > 0)


EDGE

Flag indicating that a line is defined by two grids.

GA#

Grid point identification number of first grid A.


No default (Integer > 0)

GB#

Grid point identification number of second grid B.


No default (Integer > 0)

ELEDGE

Flag indicating that the line is composed of elements.

EID#

Element identification number.


No default (Integer > 0)

SET

Flag indicating that the line is defined by a SET of elements.

Altair Engineering

OptiStruct 13.0 Reference Guide 1095


Proprietary Information of Altair Engineering

Field

Contents

SID

Set identification number.


No default (Integer > 0)

Comments
1.

LINEID is not unique, multiple LINE cards with the same LINEID compose a line group.

2.

GA and GB should be two different grids.

3.

All nodes must belong to a shell, solid, truss or beam element.

4.

This card is represented as a contactsurf in HyperMesh.

1096 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

LOAD
Bulk Data Entry
LOAD Static Load Combination (Superposition)
Description
Defines a static load as a linear combination of load sets defined via FORCE, MOMENT,
FORCE1, MOMENT1, PLOAD, PLOAD1, PLOAD2, PLOAD4, RFORCE, DAREA and GRAV entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

LOAD

SID

S1

L1

S2

L2

S3

L3

S4

L4

(10)

-etc-

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

LOAD

101

-0.5

1.0

6.2

Field

Contents

SID

Load set identification number.

(8)

(9)

(10)

(Integer > 0)
S

Scale factor.
(Real)

Si

Scale factors.
(Real)

Li

Load set identification numbers defined via entry typed enumerated above.
(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1097


Proprietary Information of Altair Engineering

Comments
1.

The load vector defined is given by

2.

The Li must be unique.

3.

All data after the first blank field is ignored.

4.

Load sets must be selected in the Subcase Information section (LOAD=SID) if they are to
be applied to the structural model.

5.

A LOAD entry may not reference a set identification number defined by another LOAD
entry.

6.

SPCD load SIDs cannot be referenced by LOAD data.

7.

This card is represented as a loadcollector in HyperMesh.

1098 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

LOADADD
Bulk Data Entry
LOADADD Static Load Combination (Superposition)
Description
Defines a static load as a linear combination of load sets defined via FORCE, MOMENT,
FORCE1, MOMENT1, PLOAD, PLOAD1, PLOAD2, PLOAD4, RFORCE, DAREA, and GRAV entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

LOADADD

SID

S1

L1

S2

L2

S3

L3

S4

L4

(10)

-etc-

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

LOADADD

101

-0.5

1.0

6.2

Field

Contents

SID

Load set identification number.

(8)

(9)

(10)

(Integer > 0)
S

Scale factor (See comment 1).


(Real)

Si

Scale factors (See comment 1).


(Real)

Li

Load set identification numbers defined via entry typed enumerated above

Altair Engineering

OptiStruct 13.0 Reference Guide 1099


Proprietary Information of Altair Engineering

Field

Contents
(See comment 1).
(Integer > 0)

Comments
1.

The load vector defined is given by:

r
P

r
Si PLi

Where,

r
P is the static load as a linear combination of the defined load sets.
S is the scale factor defined in Field 3.

Si

r
PLi

are the scale factors defined in the S1, S2,, Sn fields.


are the loads, whose ids, are referenced by the L1, L2,, Ln fields.

2.

The Load Set identification numbers (Li) must be unique.

3.

All data after the first blank field is ignored.

4.

Load sets must be selected in the Subcase Information section (LOAD=SID) if they are to
be applied to the structural model.

5.

A LOADADD entry may not reference a set identification number defined by another
LOADADD entry.

6.

Only a single thermal load can be referenced by the LOADADD data.

7.

SPCD load SIDs cannot be referenced by LOADADD data.

8.

This card is represented as a loadcollector in HyperMesh.

1100 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MARKER
Bulk Data Entry
MARKER Define a Marker by Associating a Grid and a Coordinate System
Description
Define a marker by associating a grid and a coordinate system.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MARKER

MID1

GID1

C ID1

MID2

GID2

C ID2

MID3

GID3

C ID3

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MARKER

345

123

Field

Contents

MIDi

Marker identification number.

(5)

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
GIDi

Grid identification number.


(Integer > 0)

CIDi

Coordinate system identification number.


(Integer > 0 or blank)
Default (Blank, defaults to basic coordinate system)

Altair Engineering

OptiStruct 13.0 Reference Guide 1101


Proprietary Information of Altair Engineering

Comments
1.

Each marker has a unique ID. The marker gets its location from the grid corresponding to
the GID and the orientation from the coordinate system (CID).

2.

Multiple markers can be located at the same grid with the same or with a different CID.

3.

This card is represented as a sensor in HyperMesh.

1102 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MAT1
Bulk Data Entry
MAT1 Material Property Definition, Form 1
Description
Defines the material properties for linear, temperature-independent, and isotropic materials.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT1

MID

NU

RHO

TREF

GE

ST

SC

SS

(10)

Example

(1)

(2)

(3)

MAT1

17

3.+7

(4)

(5)

(6)

0.33

4.28

Field

Contents

MID

Unique material identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


E

Youngs Modulus.
Default = blank (Real or blank)

Shear Modulus.
Default = blank (Real or blank)

NU

Poissons Ratio.
Default = blank (-1.0 < Real < 0.5 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1103


Proprietary Information of Altair Engineering

Field

Contents

RHO

Mass density.
No default (Real)

Thermal expansion coefficient.


No default (Real)

TREF

Reference temperature for thermal loading.


Default = 0.0 (Real)

GE

Structural Element Damping coefficient. See comments 11 and 12.


No default (Real)

ST, SC, SS Stress limits in tension, compression and shear. Used for composite ply
failure calculations
No default (Real)
Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT8 and MAT9
entries.

2.

The mass density, RHO, is used to automatically compute mass for all structural elements.

3.

Either E or G must be specified (that is, nonblank).

4.

If any one of E, G, or NU is blank, it is computed to satisfy the identity


E = 2(1+NU)G; otherwise, values supplied by you are used.

5.

If E and NU are both blank, they are both given the value 0.0.

6.

If G and NU are both blank, they are both given the value 0.0.

7.

Implausible data on one or more MAT1 entries result in a warning message. Implausible
data is defined as:
E < 0.0 or
G < 0.0 or
NU > 0.5 or
NU < -1.0 or

1104 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

except for cases covered by comments 5 and 6.


8.

It is strongly recommended that only two of the three values E, G, and NU be input.

9.

A warning is issued if NU < 0.0.

10. The large field format may also be used.


11. To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0 by 2.0.
12. TREF and GE are ignored if a MAT1 entry is referenced by a PCOMP entry.
13. This card is represented as a material in HyperMesh.
Element Type

NU

CROD, CBAR, CBEAM,


and CWELD

Axial and
Bending

N/A

Transverse Shear
and Torsion

CSHEAR

N/A

N/A

Shear

CQUAD and CTRIA

Membrane
Membrane
and Bending and Bending

Transverse Shear

CHEX, CTETRA,
CPENTA, CPRYRA and
CSEAM

Deformation

N/A

Altair Engineering

OptiStruct 13.0 Reference Guide 1105


Proprietary Information of Altair Engineering

MAT2
Bulk Data Entry
MAT2 Material Property Definition, Form 2
Description
Defines the material properties for linear, temperature-independent, anisotropic materials for
two-dimensional elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MAT2

MID

G11

G12

G13

G22

G23

G33

RHO

A1

A2

A12

TREF

GE

ST

SC

SS

Example

(1)

(2)

(3)

MAT2

13

6.2+3

6.5-6

6.5-6

(4)

(5)

(6)
6.2+3

(7)

(8)

(9)

5.1+3

0.056

(10)

-500.0

Field

Contents

MID

Unique material identification number.


No default (Integer > 0)

Gij

The material property matrix.


No default (Real)

RHO

Mass density.
No default (Real)

1106 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Ai

Thermal expansion coefficient vector.


No default (Real)

TREF

Reference temperature for the calculation of thermal loads. See comment


6.
Default = blank (Real or blank)

GE

Structural Element Damping Coefficient. See comments 7 and 8.


No default (Real)

ST, SC, SS Stress limits in tension, compression and shear. Used for composite ply
failure calculations.
No default (Real)
Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT8 and MAT9
entries.

2.

The mass density, RHO, is used to automatically compute mass for all structural elements.

3.

The convention for the Gij in fields 3 through 8 are represented by the matrix relationship:

4.

If this entry is referenced by the MID3 field (transverse shear) on the PSHELL, G13, G23,
and G33 must be blank.

5.

Unlike the MAT1 entry, data from the MAT2 entry is used directly, without adjustment of
equivalent E, G, or NU values.

6.

TREF is used as the reference temperature for the calculation of thermal loads.

7.

The long field format may be used.

8.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0, by 2.0.

9.

TREF and GE are ignored if a MAT 2 entry is referenced by a PCOMP entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1107


Proprietary Information of Altair Engineering

10. If a MAT2 card is pointed to by a MID4 on PSHELL, and has a material ID greater than
400,000,000, then the thermal membrane-bending coefficients A1, A2, and A12 have a
modified interpretation, and represent [G]*[alpha] rather then [alpha]. Here, [G] is a
matrix composed of G11, G22 G33. This is to maintain consistency with respective
terms generated internally by the PCOMP card.
11. This card is represented as a material in HyperMesh.

1108 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MAT3
Bulk Data Entry
MAT3 Material Property Definition, Form 3
Description
Defines the material properties for linear, temperature-independent, and orthotropic materials
used by the CTAXI and CTRIAX6 axisymmetric elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MAT3

MID

EX

ETH

EZ

NUXTH

NUTHZ

NUZX

RHO

GZX

AX

ATH

AZ

TREF

GE

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT3

17

3.0+7

3.1+7

3.2+7

0.33

0.28

0.30

2.0e-5

7.0+6

1.1e-4

1.1e-4

1.2e-4

35.5

0.19

Field

Contents

MID

Unique material identification number.

(10)

No default (Integer > 0)


EX, ETH,
EZ

Youngs Moduli in the x, and z directions, respectively.


No default (Real > 0.0)

NUXTH,
NUTHZ,
NUZX

Poissons Ratios:
NUXTH = Poissons Ratio for strain in the direction when stress in the x

Altair Engineering

OptiStruct 13.0 Reference Guide 1109


Proprietary Information of Altair Engineering

Field

Contents
direction.
NUTHZ = Poissons Ratio for strain in the z direction when stress in the
direction.
NUZX = Poissons Ratio for strain in the x direction when stress in the z
direction.
No default (Real)

RHO

Mass density.
No default (Real)

GZX

Shear Modulus in the x-z plane.


No default (Real > 0.0)

AX, ATH,
AZ

Thermal expansion coefficient in the x, , and z directions, respectively.


No default (Real)

TREF

Reference temperature for thermal loading.


Default = blank (Real or blank)

GE

Structural Element Damping coefficient. See comment 6.


No default (Real)

Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT8 and MAT9
entries.

2.

Values of all seven elastic constants, EX, ETH, EZ, NUXTH, NUTHZ, NUZX and GZX must
be present.

3.

A warning is issued if absolute value of NUXTH or NUTHZ is greater than 1.0.

4.

The x, and z directions are principal material directions of the material coordinate
system. Each element (that is a CTAXI or CTRIAX6 element) supporting the use of MAT3
contains a Theta field to relate the principal material directions to the basic coordinate
system.

5.

The strain-stress relationship is:

1110 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Note that the strain and stress here are both defined in the material coordinate system.
6.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0, by 2.0.

7.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1111


Proprietary Information of Altair Engineering

MAT4
Bulk Data Entry
MAT4 Material Property Definition, Form 4
Description
Defines constant thermal material properties for conductivity, density, and heat generation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MAT4

MID

CP

RHO

(7)

(8)

(9)

(10)

HGEN

Example

(1)

(2)

(3)

MAT4

24

200

(4)

Field

Contents

MID

Material identification number.

(5)

(6)

(7)

(8)

(9)

(10)

2e5

No default (Integer > 0)


K

Thermal conductivity.
Default = 0.0 (Real > 0.0)

CP

Heat capacity per unit mass (specific heat).


(Real > 0.0 or blank)

RHO

Density.
Default = 1.0 (Real > 0.0)

Free convection heat transfer coefficient.


Default = 0.0 (Real)

1112 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

HGEN

Heat generation capability used with QVOL entries. HGEN is the scale factor
used with QVOL (See comment 3).
Default = 1.0 (Real > 0.0)

Comments
1.

The material identification number may be the shared with structural material property
definitions (MAT1, MAT2, MAT8, MAT9 or MGASK) but must be unique with respect to
other thermal material property definitions (MAT4 or MAT5).

2.

MAT4 may specify material properties for any conduction elements. MAT4 also provides
the heat transfer coefficient for free convection (see CONV).

3.

HGEN is the scale factor and QVOL is the power generated per unit volume, Pin = volume *

HGEN * QVOL.
4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1113


Proprietary Information of Altair Engineering

MAT5
Bulk Data Entry
MAT5 Material Property Definition, Form 5
Description
Defines the thermal material properties for anisotropic materials.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT5

MID

KXX

KXY

KXZ

KYY

KYZ

KZZ

CP

RHO

HGEN

(10)

Example

(1)

(2)

(3)

MAT5

.300

(4)

(5)

(6)

(7)

100

(8)

(9)

(10)

200

2e5

Field

Contents

MID

Material identification number.


No default (Integer > 0)

Kij

Thermal conductivity.
Default = 0.0 (Real)

CP

Heat capacity per unit mass (specific heat).


(Real > 0.0 or blank)

RHO

Density.
Default = 1.0 (Real > 0.0)

1114 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

HGEN

Heat generation capability used with QVOL entries. HGEN is the scale factor
used with QVOL (See comment 3).
Default = 1.0 (Real > 0.0)

Comments
1.

The material identification number may be the shared with structural material property
definitions (MAT1, MAT2, MAT8, MAT9 or MGASK), but must be unique with respect to
other thermal material property definitions (MAT4 or MAT5).

2.

The thermal conductivity matrix has the following form:

3.

HGEN is the scale factor and QVOL is the power generated per unit volume, Pin = volume *

HGEN * QVOL.
4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1115


Proprietary Information of Altair Engineering

MAT8
Bulk Data Entry
MAT8 Material Property Definition, Form 8
Description
Defines the material properties for linear temperature-independent orthotropic material for
two-dimensional elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MAT8

MID

E1

E2

NU12

G12

G1,Z

G2,Z

RHO

A1

A2

TREF

Xt

Xc

Yt

Yc

GE

F12

STRN

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT8

171

30.+6

1.+6

0.3

2.+6

3.+6

1.5+6

0.056

28.-6

1.5-6

155.0

Field

Contents

MID

Material ID.

(10)

No default (Integer > 0)


E1

Modulus of elasticity in longitudinal direction (also defined as fibre direction or 1direction) (See comment 8)

1116 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

E2

Modulus of elasticity in lateral direction (also defined as matrix direction or 2direction) (See comment 8).

NU12
Poissons ratio (

for uniaxial loading in 1-direction). Note that

uniaxial loading in 2-direction is related to

for

by the relation

.
No default (Real)
G12

Inplane shear modulus.


No default (Real > 0.0)

G1,Z

Transverse shear modulus for shear in 1-Z plane.


Default = blank (Real > 0.0 or blank)

G2,Z

Transverse shear modulus for shear in 2-Z plane.


Default = blank (Real > 0.0 or blank)

RHO

Mass density.
No default (Real)

A1

Thermal expansion coefficient in 1-direction.


No default (Real)

A2

Thermal expansion coefficient in 2-direction.


No default (Real)

TREF

Reference temperature for the calculation of thermal loads. See comment 3.


Default = blank (Real or blank)

Xt, Xc,
Yt, Yc

Allowable stresses or strains in the longitudinal and lateral directions. Used for
composite ply failure calculations.

Altair Engineering

OptiStruct 13.0 Reference Guide 1117


Proprietary Information of Altair Engineering

Field

Contents
No default (Real > 0.0)

Allowable for in-plane shear for composite ply failure calculations.


No default (Real > 0.0)

GE

Structural Element Damping Coefficient. See comment 6.


No default (Real)

F12

Tsai-Wu interaction term for composite failure.


No default (Real)

STRN

Indicates whether Xt, Xc, Yt, or Yc are stress or strain allowables.


Default = blank (Real = 1.0 for strain allowables, blank for stress allowables)

Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT8 and MAT9
entries.

2.

If G1, Z and G2, Z values are specified as zero or are not supplied, a penalty term is used
to enforce very high transverse shear stiffness.

3.

An approximate value for G1, Z and G2, Z is the inplane shear modulus G12. If test data
not available to accurately determine G1, Z and G2, Z for the material and transverse
shear calculations, the value of G12 may be supplied for G1, Z and G2, Z.

4.

TREF is used as the reference temperature for calculations of thermal loads.

5.

Long field format can be used.

6.

TREF and GE are ignored if a MAT8 entry is referenced by a PCOMP entry.

7.

The option of interpreting Xt, Xc, Yt, and Yc as strains is only available for composite
definitions (PCOMP or PCOMPG) using the STRN failure criterion. In this case, the STRN
flag indicates whether Xt, Xc, Yt, and Yc are stress or strain allowables.
For all other failure criteria Xt, Xc, Yt, and Yc are always interpreted as stresses,
regardless of the value of the STRN flag.

8.

The value of E1 should be greater than that of E2 for the material to be stable. If E1 <
E2, then the material matrix becomes indefinite leading to an unstable material.

9.

This card is represented as a material in HyperMesh.

1118 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MAT9
Bulk Data Entry
MAT9 Material Property Definition, Form 9
Description
Defines the material properties for linear, temperature-independent, and anisotropic materials
for solid elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT9

MID

G11

G12

G13

G14

G15

G16

G22

G23

G24

G25

G26

G33

G34

G35

G36

G44

G45

G46

G55

G56

G66

RHO

A1

A2

A3

A4

A5

A6

TREF

GE

(10)

Example

(1)

(2)

(3)

MAT9

17

6.2+3

(4)

(5)

(6)

(7)

(8)

(9)

(10)

6.2+3

6.2+3

5.1+3

5.1+3

6.5-6

3.2

6.5 - 6

125.

Field

Contents

MID

Unique material identification number.

Altair Engineering

5.1 + 3

OptiStruct 13.0 Reference Guide 1119


Proprietary Information of Altair Engineering

Field

Contents
No default (Integer > 0)

Gij

The material property matrix.


No default (Real)

RHO

Mass density.
No default (Real)

Ai

Thermal expansion coefficient vector.


No default (Real)

TREF

Reference temperature for the calculation of thermal loads. See comment 6.


Default = blank (Real or blank)

GE

Structural Element Damping Coefficient. See comment 9.


No default (Real)

Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT8, MAT9ORT
and MAT9 entries.

2.

The mass density, RHO, is used to automatically compute mass for all structural elements.

3.

The convention for the Gij in fields 3 through 8 are represented by the matrix relationship.

The subscripts 1 to 6 refer to x, y, z, xy, yz, and zx of the material coordinate system
defined by the CORDM field on the PSOLID entry.
4.

Unlike the MAT1 entry, data from the MAT9 entry is used directly, without adjustment of
equivalent E, G, or NU values.

1120 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

If material data is to specified with the Engineering Constants E1, E2, E3, NU12, NU13,
NU23, G12, G23, and G13, then use the MAT9ORT data.

6.

TREF is used as the reference temperature for the calculation of thermal loads.

7.

The last continuation is optional.

8.

Long field format can be used.

9.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0, by 2.0.

10. This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1121


Proprietary Information of Altair Engineering

MAT9ORT
Bulk Data Entry
MAT9ORT Material Property Definition, Form 9-Orthotropic
Description
Defines the material properties for linear, temperature-independent, and orthotropic materials
for solid elements in terms of engineering constants.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MAT9ORT

MID

E1

E2

E3

NU12

NU23

NU31

RHO

G12

G23

G31

A1

A2

A3

TREF

GE

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MAT9ORT

21

1e6

1e3

1e3

0.1

0.1

1e3

1e3

1e-6

1e-6

1e-6

(8)

(9)

(10)

1e5

Field

Contents

MID

Material identification number. Must be unique with respect to other MAT1,


MAT2, MAT8, MAT9, and MAT9ORT definitions
No default (Integer > 0)

E1

Elastic modulus in 1-direction.


No default (Real)

E2

Elastic modulus in 2-direction.


No default (Real)

1122 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

E3

Elastic modulus in 3-direction.


No default (Real)

NU12

Poissons ratio for uniaxial loading in 1-direction. See comment 3.


No default (Real)

NU23

Poissons ratio for uniaxial loading in 2-direction. See comment 3.


No default (Real)

NU31

Poissons ratio for uniaxial loading in 3-direction. See comment 3.


Default = NU23 (Real)

RHO

Mass density.
No default (Real)

G12

Shear modulus on plane 1-2.

G23

Shear modulus on plane 2-3.

G31

Shear modulus on plane 3-1.

Ai

Coefficient of thermal expansion in the i-direction


Default =0.0 (Real)

TREF

Reference temperature for the calculation of thermal loads. See comment 5.


Default = blank (Real or blank)

GE

Structural Element Damping Coefficient. See comment 6.


Default = 0.0 (Real)

Comments
1.

This input definition is internally converted to an equivalent MAT9 definition on reading


(See comment 7). This is reflected in echoed (ECHO) input data and all messaging.

Altair Engineering

OptiStruct 13.0 Reference Guide 1123


Proprietary Information of Altair Engineering

2.

The material identification number must be unique for all MAT1, MAT2, MAT8, MAT9 and
MAT9ORT entries.

3.

In general,

is not the same as

, but they are related by

Furthermore, material stability requires that:

and

4.

It may be difficult to find all nine orthotropic constants. In some practical problems, the
material properties may be reduced to normal anisotropy in which the material is isotropic
in a plane (for example, plane 1-2), and has different properties in the direction normal to
this plane.
In the plane of isotropy, the properties are reduced to:

with

and

There are five independent material constants for normal anisotropy


.
In case the material has a planar anisotropy, in which the material is orthotropic only in a
plane, the elastic constants are reduced to seven

5.

TREF is used as the reference temperature for the calculation of thermal loads.

6.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0 by 2.0.

7.

Internal conversion from MAT9ORT to MAT9. The material property fields of the MAT9
entry are calculated internally from the MAT9ORT entry using the following formula:

1124 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Where,

The values of , E and G for the expressions in the above equations in comment 7 are
taken from the NUij , Ei and Gij fields respectively of this MAT9ORT entry where i, j
{1,2,3} and the values of
(see above equations
in comment 7) are used to populate the G11, G22, G33, G44, G55, G66, G12, G13, and G23
fields (G12=G21, G13=G31 and G23=G32 due to symmetry) of the MAT9 entry. The
remaining elements of the MAT9 entry (that is G14, G15, G24, and so on) are equal to
zero.

Altair Engineering

OptiStruct 13.0 Reference Guide 1125


Proprietary Information of Altair Engineering

MAT10
Bulk Data Entry
MAT10 Material Property Definition, Form 10
Description
Defines material properties for fluid elements in coupled fluid-structural analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MAT10

MID

BULK

RHO

GE

ALPHA

(9)

(10)

Example

(1)

(2)

(3)

(4)

MAT10

0.5

22.1

(5)

Field

Contents

MID

Material identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


BULK

Bulk modulus.
No default (Real > 0.0)

RHO

Mass density.
No default (Real > 0.0)

Speed of sound.
No default (Real > 0.0)

GE

Fluid element damping coefficient.


No default (Real)

1126 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field
ALPHA

Contents
Normalized porous material damping coefficient. See comment 6.
No default (Real)

Comments
1.

MAT10 may be referenced by PSOLID entries with FCTN=PFLUID.

2.

The material identification number must be unique with respect to MAT1, MAT2, MAT3,
MAT9, and MAT10 entries, but may be shared with MAT4, MAT5 or MATFAT.

3.

The mass density RHO will be used to compute the mass automatically.

4.

BULK, RHO, and C are related by BULK = C2 * RHO.


Two out of the three must be specified, and the other will be calculated according to this
equation.

5.

To obtain the damping coefficient GE, multiply the critical damping ratio C/C0 by 2.0.

6.

Since the admittance is a function of frequency, the value of ALPHA should be chosen for
the frequency range of interest for the analysis.

7.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1127


Proprietary Information of Altair Engineering

MATFAT
Bulk Data Entry
MATFAT - Fatigue Material Data
Description
Defines material properties for fatigue analysis.
Format
(1)

(2)

(3)

(4)

MATFAT

MID

UNIT

STATIC

YS

(5)

(6)

(7)

(8)

FL

SE

np

Kp

(9)

(10)

UTS

Optional continuation lines for SN fatigue properties:


SN

SR1

b1

Nc1

b2

Optional continuation lines for EN fatigue properties:


EN

Sf

SEe

SEp

Ef

Nc

Optional continuation lines for factor of safety (FOS) analysis:


FOS

Tfl

Hss

Field

Contents

MID

Material identification number that matches the identification number on a


MAT1 bulk data entry.
No default (Integer > 0)

UNIT

Defines the units of stress values specified on the YS, UTS, SRI1, FL, Sf, and
Kp fields
Default = MPa (MPa, PA, PSI, or KSI)

1128 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

STATIC

STATIC flag indicates that static material properties are defined in the following
fields.

YS

Yield strength. See comment 1.


(Real > 0.0, or blank)

UTS

Ultimate tensile strength. See comment 1.


(Real > 0.0, or blank)

SN

SN flag indicating that fatigue material properties for SN analysis are following.

SRI1

Fatigue strength coefficient. It is the stress range intercept of SN curve at 1


cycle in log-log scale.
No default (Real > 0.0)

b1

The first fatigue strength exponent. It is the slope of the first segment of SN
curve in log-log scale.
No default (Real < 0.0)

Nc1

In one-segment S-N curve, this is the cycle limit of endurance (see NC1 in
Figure 1).
In two-segment S-N curve, this is the transition point (see NC1 in Figure 2).
No default (Real > 1000.0)

b2

The second fatigue strength exponent. It is the slope of the second segment
of SN curve in log-log scale.
Default = 0.0 (Real < 0.0)

FL

Fatigue Limit; No damage occurs if the stress range is less than FL (see FL in
Figures 1 and 2). See comment 6.
(Real > 0.0, or blank)

SE

Standard Error of Log(N).


Default = 0.0 (Real > 0.0)

EN

EN flag indicating that fatigue material properties for EN analysis are following.

Sf

Fatigue strength coefficient.


No default (Real > 0.0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1129


Proprietary Information of Altair Engineering

Field

Contents

Fatigue strength exponent.


No default (Real < 0.0)

Fatigue ductility exponent.


No default (Real < 0.0)

Ef

Fatigue ductility coefficient.


No default (Real > 0.0)

np

Cyclic strain-hardening exponent.


No default (Real > 0.0)

Kp

Cyclic Strength coefficient.


No default (Real > 0.0)

Nc

Reversal limit of endurance. One cycle contains two reversals. See comment
6.
Default = 2.0E8 (Real > 1.0E5)

SEe

Standard Error of Log(N) from elastic strain.


Default = 0.0 (Real > 0.0)

SEp

Standard Error of Log(N) from plastic strain.


Default = 0.0 (Real > 0.0)

FOS

The FOS flag indicates that material properties for factor of safety analysis are
defined in the following fields.

Tfl

Torsion fatigue limit.


No default (Real > 0.0)

Hss

Hydrostatic stress sensitivity.


No default (Real > 0.0)

1130 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figures

Figure 1a: One-segment S-N curve in log-log scale


(b2=0)
(Nc1 is not defined or less conservative than FL)

Figure 1b: One-segment S-N curve in log-log scale


(b2=0)
(FL is not defined or less conservative than Nc1)

Figure 2: Two-segment S-N curve in log-log scale

Altair Engineering

OptiStruct 13.0 Reference Guide 1131


Proprietary Information of Altair Engineering

Figure 3: E-N curve in log-log scale

Comments
1.

UTS or YS is used in mean stress correction (SN) and surface finish correction (SN and
EN). If both UTS and YS are defined, UTS will be used. It is not allowed that both UTS
and YS are blanks.

2.

S-N data defined in the MATFAT card is expected to be obtained from standard
experiments that are fully reversed bending on mirror-polished specimens.

3.

S-N curves are defined in Stress range Cycle form. Stress range is the algebraic
difference between the maximum and minimum stress in a cycle. SN curve is expressed
as:

Where S r is the stress range, SRI1 is the fatigue strength coefficient,


number, is the fatigue strength exponent.
4.

is the cycle

E-N curves are defined in Strain amplitude - Reversal form. Strain amplitude is half of the
algebraic difference between the maximum and minimum strain in a cycle, and one strain
cycle contains two reversals. EN curve is expressed as:

Where,
modulus,

is the strain amplitude,


is the cycle number,

is the fatigue strength coefficient, E is the Young's


is the fatigue strength exponent,

1132 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

is the fatigue

Altair Engineering

ductility coefficient, and


5.

is the fatigue ductility exponent.

Empirical formula can be used to estimate SN/EN data from ultimate tensile strength
(UTS) and Youngs modulus (E):

Table 1* Estimated S-N data from empirical formula


(* Source: Yung-Li Lee, Jwo. Pan, Richard B. Hathaway and Mark E. Barekey. Fatigue testing and
analysis: Theory and practice, Elsevier, 2005)

Table 2**. Estimate E-N data from UTS and E


(** Source: Anton Baumel and T. Seeger, Materials Data for C yclic Loading, Elsevier, 1990)

6.

For one-segment SN curve (b2=0.0), if FL is blank, the fatigue limit is the stress range at
Nc1. If both Nc1 and FL are defined, the more conservative value (larger damage) will be
used (Figure 1).
For two-segment SN curve, if FL is blank, the fatigue limit is 0.0.
When fatigue optimization is performed, fatigue limit FL of S-N data and reversal limit Nc
of E-N data will be ignored in order to get continuous changes in fatigue results when
stress/strain changes.

7.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1133


Proprietary Information of Altair Engineering

MATF1
Bulk Data Entry
MATF1 Isotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT1 entry fields via TABLEDi entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATF1

MID

T(E)

T(G)

T(NU)

T(RHO)

T(A)

T(ST)

T(SC )

T(SS)

(9)

(10)

T(GE)

Example

(1)

(2)

(3)

MATF1

17

32

(4)

(5)

(6)

(7)

(8)

17

(9)

(10)

53

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT1 entry.
(Integer > 0)

T(E)

Identification number of a TABLEDi entry for the Youngs modulus.


(Integer > 0 or blank)

T(G)

Identification number of a TABLEDi entry for the shear modulus.


(Integer > 0 or blank)

T(NU)

Identification number of a TABLEDi entry for the Poissons ratio.


(Integer > 0 or blank)

1134 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(RHO)

Identification number of a TABLEDi entry for the mass density.


(Integer > 0 or blank)

T(A)

Identification number of a TABLEDi entry for the thermal expansion


coefficient.
(Integer or blank)

T(GE)

Identification number of a TABLEDi entry for the damping coefficient.


(Integer > 0 or blank)

T(ST)

Identification number of a TABLEDi entry for the tension stress limit.


(Integer > 0 or blank)

T(SC)

Identification number of a TABLEDi entry for the compression limit.


(Integer > 0 or blank)

T(SS)

Identification number of a TABLEDi entry for the shear limit.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT1 entry referenced in field 2. The value in a particular field of the MAT1 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, E is modified by TABLEDi 32, RHO is modified by TABLEDi 17 and GE is
modified by TABLEDi 53. Blank or zero entries mean that there is no frequency
dependence of the field on the MAT1 entry.

2.

The MATF1 entries may refer to blank entries on the respective MAT1 card. In this case,
they will be applied to default values of respective parameters. Initial values of E, G, or
NU will be supplied according to comment 4 on the MAT1 entry.

3.

Table references must be present for each item that is frequency dependent. For
example, it is not sufficient to only give table references for fields 3 and 4 (Youngs
modulus and shear modulus) if density is also frequency dependent.

4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1135


Proprietary Information of Altair Engineering

MATF2
Bulk Data Entry
MATF2 Anisotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT2 entry fields via TABLEDi entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF2

MID

T(G11)

T(G12)

T(G13)

T(G22)

T(G23)

T(G33)

T(RHO)

T(A1)

T(A2)

T(A3)

T(GE)

T(ST)

T(SC )

T(SS)

Example

(1)

(2)

(3)

MATF2

17

32

(4)

(5)

(6)

(7)

(8)

(9)

15

44

(10)

62

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT2 entry.
(Integer > 0)

T(Gij)

Identification number of a TABLEDi entry for the shear modulus.


(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEDi entry for the mass density.


(Integer > 0 or blank)

T(Ai)

Identification number of a TABLEDi entry for the thermal expansion

1136 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
coefficient.
(Integer or blank)

T(GE)

Identification number of a TABLEDi entry for the damping coefficient.


(Integer > 0 or blank)

T(ST)

Identification number of a TABLEDi entry for the tension stress limit.


(Integer > 0 or blank)

T(SC)

Identification number of a TABLEDi entry for the compression limit.


(Integer > 0 or blank)

T(SS)

Identification number of a TABLEDi entry for the shear limit.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT2 entry referenced in field 2. The value in a particular field of the MAT2 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, G11 is modified by TABLEDi 32; G33 is modified by TABLEDi 15; RHO is
modified by TABLEDi 44 and GE is modified by TABLEDi 62. Blank or zero entries mean that
there is no frequency dependence of the field on the MAT2 entry.

2.

The MATF2 entries may refer to blank entries on the respective MAT2 card. In this case,
they will be applied to default values of respective parameters.

3.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1137


Proprietary Information of Altair Engineering

MATF3
Bulk Data Entry
MATF3 Orthotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT3 data entry fields via TABLEDi
entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF3

MID

T(EX)

T(ETH)

T(EZ)

T(NUXTH)

T(NUTHZ)

T(NUZX)

T(RHO)

T(GZX)

T(AX)

T(ATH)

T(AZ)

T(GE)

Example

(1)

(2)

(3)

MATF3

17

32

(4)

(5)

(6)

(7)

(8)

(9)

(10)

19

52

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT3 entry.
(Integer > 0)

T(EX)
T(ETH)
T(EZ)

Identification numbers of TABLEDi entries for Youngs moduli in the x, and z


directions.

T(EX)
T(ETH)

Identification numbers of TABLEDi entries for Poissons ratios in the x, z


and zx directions.

Default = blank (Integer > 0 or blank)

1138 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(EZ)

Default = blank (Integer > 0 or blank)

T(RHO)

Identification number of a TABLEDi entry for the mass density.


Default = blank (Integer > 0 or blank)

T(GZX)

Identification number of a TABLEDi entry for the shear modulus.


Default = blank (Integer > 0 or blank)

T(AX)
T(ATH)
T(AZ)

Identification numbers of TABLEDi entries for thermal expansion coefficients in


the x, and z directions.

T(GE)

Identification number of a TABLEDi entry for the damping coefficient.

Default = blank (Integer or blank)

Default = blank (Integer > 0 or blank)


Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT3 entry referenced in field 2. The value in a particular field of the MAT3 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, EX is modified; TABLEDi 32, RHO is modified by TABLEDi 19; and GE is
modified by TABLEDi 52.

2.

Blank or zero entries mean that there is no frequency dependence of the field on the
MAT3 entry. Any quantity modified by this entry must have a value on the MAT3 entry.

3.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1139


Proprietary Information of Altair Engineering

MATF8
Bulk Data Entry
MATF8 Shell Orthotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT8 entry fields via TABLEDi entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF8

MID

T(E1)

T(E2)

T(NU12)

T(G12)

T(G1Z)

T(G2Z)

T(RHO)

T(A1)

T(A2)

T(Xt)

T(Xc)

T(Yt)

T(Yc)

T(S)

T(GE)

T(F12)

Example

(1)

(2)

(3)

MATF8

17

32

(4)

(5)

(6)

(7)

(8)

(9)

(10)

15

52

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT1 entry.
(Integer > 0)

T(E1)

Identification number of a TABLEDi entry for the Youngs modulus 1.


(Integer > 0 or blank)

1140 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(E2)

Identification number of a TABLEDi entry for the Youngs modulus 2.


(Integer > 0 or blank)

T(NU12)

Identification number of a TABLEDi entry for the Poissons ratio 12.


(Integer > 0 or blank)

T(G12)

Identification number of a TABLEDi entry for shear modulus 12.


(Integer > 0 or blank)

T(G1Z)

Identification number of a TABLEDi entry for transverse shear modulus 1Z.


(Integer > 0 or blank)

T(G2Z)

Identification number of a TABLEDi entry for transverse shear modulus 2Z.


(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEDi entry for mass density.


(Integer > 0 or blank)

T(A1)

Identification number of a TABLEDi entry for the thermal expansion coefficient


1. See comment 3.
(Integer or blank)

T(A2)

Identification number of a TABLEDi entry for the thermal expansion coefficient


2.
(Integer or blank)

T(Xt)

Identification number of a TABLEDi entry for the tension stress/strain limit 1.


(Integer > 0 or blank)

T(Xc)

Identification number of a TABLEDi entry for compression stress/strain limit 1.


(Integer > 0 or blank)

T(Yt)

Identification number of a TABLEDi entry for tension stress/strain limit 2.


(Integer > 0 or blank)

T(Yc)

Identification number of a TABLEDi entry for compression stress/strain limit 2.


(Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1141


Proprietary Information of Altair Engineering

Field

Contents

T(S)

Identification number of a TABLEDi entry for shear stress/strain limit.


(Integer > 0 or blank)

T(GE)

Identification number of a TABLEDi entry for structural damping coefficient.


(Integer > 0 or blank)

T(F12)

Identification number of a TABLEDi entry for Tsai-Wu interaction term.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT8 entry referenced in field 2. The value in a particular field of the MAT8 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, E1 is modified by TABLEDi 32; RHO is modified by TABLEDi 15; and GE
is modified by TABLEDi 52.

2.

Blank or zero entries mean that there is no frequency dependence of the fields on the
MAT8 entry. The MATF8 entries may refer to blank entries on the respective MAT8 card.
In which case, they will be applied to default values of the respective parameters.

3.

This card is represented as a material in HyperMesh.

1142 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATF9
Bulk Data Entry
MATF9 Solid Element Anisotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT9 entry fields via TABLEDi entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATF9

MID

T(G11)

T(G12)

T(G13)

T(G14)

T(G15)

T(G16)

T(G22)

T(G23)

T(G24)

T(G25)

T(G26)

T(G33)

T(G34)

T(G35)

T(G36)

T(G44)

T(G45)

T(G46)

T(G55)

T(G56)

T(G66)

T(RHO)

T(A1)

T(A2)

T(A3)

T(A4)

T(A5)

T(A6)

T(GE)

Example

(1)

(2)

(3)

MATF9

17

32

(4)

(5)

(6)

(7)

(8)

18

12

(9)

(10)

17

10

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT9 entry.
(Integer > 0)

T(Gij)

Identification number of a TABLEDi entry for the terms in the material

Altair Engineering

OptiStruct 13.0 Reference Guide 1143


Proprietary Information of Altair Engineering

Field

Contents
property matrix.
(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEDi entry for the mass density.


(Integer > 0 or blank)

T(Ai)

Identification number of a TABLEDi entry for the thermal expansion


coefficient.
(Integer or blank)

T(GE)

Identification number of a TABLEDi entry for the damping coefficient.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT9 entry referenced in field 2. The value recorded in a particular field of the MAT9
entry is replaced or modified by the table referenced in the corresponding field of this
entry. In the example shown, G11 is modified by TABLEDj 32; G14 is modified by TABLEDj
18; G22 is modified by TABLEDi 17; G26 is modified by TABLEDi 12; RHO is modified by
TABLEDi 5 and GE is modified by TABLEDi 10.

2.

If the fields are zero or blank, there is no frequency dependence of the field on the MAT9
entry. The MATF9 entries may refer to blank entries on the respective MAT9 card. In
which case, they will be applied to default values of respective parameters.

3.

The continuation entries are optional.

4.

This card is represented as a material in HyperMesh.

1144 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATF10
Bulk Data Entry
MATF10 Isotropic Material Frequency Dependence
Description
Specifies frequency-dependent material properties on MAT10 entry fields via TABLEDi entries.
Format
(1)

(2)

(3)

(4)

(5)

MATF10

MID

T(BULK)

T(RHO)

(6)

(7)

(8)

T(GE)

T(ALPHA)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MATF10

10

13

(5)

(6)

(7)

17

19

(8)

(9)

Field

Contents

MID

Material property identification number that matches the identification


number on the MAT10 entry.

(10)

(Integer > 0)
T(BULK)

Identification number of a TABLEDi entry for the bulk modulus.


(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEDi entry for the mass density.


(Integer > 0 or blank)

T(GE)

Identification number of a TABLEDi entry for fluid material damping


coefficient.
(Integer > 0 or blank)

T(ALPHA)

Identification number of a TABLEDi entry for normalized porous material

Altair Engineering

OptiStruct 13.0 Reference Guide 1145


Proprietary Information of Altair Engineering

Field

Contents
damping coefficient.
(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT10 entry referenced in field 2. The value recorded in a particular field of the
MAT10 entry is replaced or modified by the table referenced in the corresponding field of
this entry. In the example shown, BULK modulus is modified by TABLEDj 10; RHO is
modified by TABLEDj 18; G22 is modified by TABLEDi 17; G26 is modified by TABLEDi 12;
RHO is modified by TABLEDi 13; GE is modified by TABLEDi 17 and ALPHA is modified by
TABLEDi 19.

2.

If the fields are zero or blank, there is no frequency dependence of the field on the
MAT10 entry. The MATF10 entries may refer to blank entries on the respective MAT10
card. In which case, they will be applied to default values of respective parameters.

3.

The continuation entries are optional.

4.

This card is represented as a material in HyperMesh.

1146 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATHE
Bulk Data Entry
MATHE Nonlinear Hyperelastic Material Property Definition
Description
The MATHE bulk data entry defines material properties for nonlinear hyperelastic materials. The
Polynomial form is available and various material types (comment 3) can be defined by
specifying the corresponding coefficients.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MATHE

MID

Model

C 10

(7)

C 01

D1

TAB1

TAB2

C 20

C 11

C 02

D2

NA

C 30

C 21

C 12

C 03

D3

C 40

C 31

C 22

C 13

C 04

D4

C 50

C 41

C 32

C 23

C 14

C 05

(8)

(9)

(10)

TAB4

ND

D5

Example

(1)

(2)

(3)

MATHE

MOONEY

80

20

(4)

(5)

(6)

(7)

(8)

(9)

(10)

0.001

Field

Contents

MID

Unique material identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1147


Proprietary Information of Altair Engineering

Field

Contents

Model

Specifies the type of hyperelastic material model


MOONEY Selects the generalized Mooney-Rivlin hyperelastic model
Default = MOONEY (Character, <MOONEY, blank>)

NA

Order of the distortional strain energy polynomial function


No default (0 < Integer < 5)

ND

Order of the volumetric strain energy polynomial function (see comment 2).
Default = 1 (Integer)

Cpq

Material constants related to distortional deformation (Model = MOONEY).


Default = 0.0 (Real)

Dp

Material constants related to volumetric deformation (Model = MOONEY).


Default = 0.0 (Real > 0.0)

TAB1

Table identification number of a TABLES1 entry that contains simple tensioncompression data to be used in the estimation of the material constants,
Cpq, related to distortional deformation. The x-values in the TABLES1 entry
should be the stretch ratios and y-values should be values of the engineering
stress.
(Integer > 0 or blank)

TAB2

Table identification number of a TABLES1 entry that contains equi-biaxial


tension data to be used in the estimation of the material constants, Cpq,
related to distortional deformation. The x-values in the TABLES1 entry should
be the stretch ratios and y-values should be values of the engineering stress.
(Integer > 0 or blank)

TAB4

Table identification number of a TABLES1 entry that contains pure shear data
to be used in the estimation of the material constants, Cpq, related to
distortional deformation. The x-values in the TABLES1 entry should be the
stretch ratios and y-values should be values of the nominal stress.
(Integer > 0 or blank)

Comments
1.
curve fit values based on the corresponding TAB# tables. However, any Cpq values set to
0.0 are not overwritten.

1148 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

The polynomial form of the Hyperelastic material model is written as a combination of the
deviatoric and volumetric strain energy of the material. The potential (U) is written in
polynomial form, as follows:

Where,

N1 is the order of the distortional strain energy polynomial function (NA)


N2 is the order of the volumetric strain energy polynomial function (ND). Currently only
first order volumetric strain energy functions are supported (ND=1).

Cpq are the material constants related to distortional deformation (Cpq)


,

are invariants internally calculated by OptiStruct

Dp are material constants related to volumetric deformation (Dp). These values define the
compressibility of the material.

Jelas is the elastic volume strain calculated internally by OptiStruct


3.

The polynomial form can be used to model the following material types by specifying the
corresponding coefficients (Cpq, Dp) on the MATHE entry:
Mooney-Rivlin Material:
N1 = N2 =1

C10 I1

C01 I 2

1
J elas
D1

Reduced Polynomial:
q=0
N1

C p 0 I1

N2

p 1

1
J elas
1 Dp

2p

Neo-Hooken Material
N1= N2 =1, q=0

C10 I1

Altair Engineering

1
J elas
D1

OptiStruct 13.0 Reference Guide 1149


Proprietary Information of Altair Engineering

Yeoh Material
N1 = N2 =3, q=0

C10 I1

1
J elas
D1

C20 I1

1
J elas
D2

C30 I1

1
J elas
D3

Three term Mooney-Rivlin Material:

C10 I1

C01 I 2

C11 I1

3 I2

C20 I1

C11 I1

3 I2

Signiorini Material:

C10 I1

C01 I 2

Third Order Invariant Material:

C10 I1

C01 I 2

C20 I1

Third Order Deformation Material (James-Green-Simpson):

C10 I1

C01 I 2

C11 I1

3 I2

C20 I1

C30 I1

4.

The MATHE hyperelastic material supports CTETRA (4, 10), CPENTA (6, 15), and CHEXA
(8, 20) element types.

5.

This card is represented as a material in HyperMesh.

1150 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATHF
Bulk Data Entry
MATHF Material Property Definition for One-step Stamping Simulation
Description
Defines the material properties in a one-step stamping simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATHF

MID

NU

EPS0

R0

R45

R90

TABLEID

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATHF

17

21.0E4

0.3

184.297

549.03

0.22

0.007

1.6

1.6

1.6

Field

Contents

MID

Unique material identification number.


No default (Integer > 0)

Youngs Modulus.
No default (Real)

NU

Poissons Ratio.
Default = blank (-1.0 < Real < 0.5 or blank)

Yield stress.
No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1151


Proprietary Information of Altair Engineering

Field

Contents

Strength coefficient.
No default (Real or blank)

Strain hardening component.


No default (Real or blank)

EPS0

Pre-strain coefficient.
No default (Real or blank)

R0, R45, R90

Lankford coefficients.
No default (Real)

TABLEID

Table ID for stress-strain curve using a TABLES1 entry.


No default (Integer > 0)

Comments
1.

This entry is only valid with a @HyperForm statement in the first line of the input file.

2.

The TABLEID and the corresponding curve are required only when material data is
specified with a stress-strain curve. For such case, material parameter such as K, n and
EPS0 are extracted from the stress strain curve.

1152 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATPE1
Bulk Data Entry
MATPE1 Material Property Definition
Description
Defines the material properties for poro-elastic materials.
Format
(1)

(2)

(3)

(4)

(5)

MATPE1

MID

MAT1

MAT10

BIOT

VISC

GAMMA

PRANDTL

POR

(6)

(7)

(8)

(9)

TOR

AFR

VLE

TLE

(10)

Example

(1)

(2)

(3)

(4)

(5)

MATPE1

17

10

1.0

1.8-8

1.41

7.0-1

8.0-1

Field

Contents

MID

Unique material identification number.

(6)

(7)

(8)

(9)

1.2

2.-5

1.0-1

9.3-2

(10)

No default (Integer > 0)


MAT1

Material identification number of the MAT1 bulk data entry (or MATF1 if it is
frequency-dependent) for the skeleton.
No default (Integer > 0)

MAT10

Identification number of MAT10 bulk data entry for the porous material.
No default (Integer > 0)

BIOT

BIOT factor

Altair Engineering

OptiStruct 13.0 Reference Guide 1153


Proprietary Information of Altair Engineering

Field

Contents
Default = 1.0 (Real > 0.0)

VISC

Fluid dynamic viscosity


No default (Real > 0.0)

GAMMA

Fluid ratio of specific heats.


Default = 1.402 (Real > 0.0)

PRANDTL

Fluid Prandtl number.


Default = 0.71 (Real > 0.0)

POR

Porosity of the porous material.


No default (Real > 0.0)

TOR

Tortuosity of the porous material.


Default = 1.0 (Real > 0.0)

AFR

Air flow resistivity.


No default (Real > 0.0)

VLE

Viscous characteristic length.


No default (Real > 0.0)

TLE

Thermal characteristic length.


No default (Real > 0.0)

Comments
1. This entry is represented as a material in HyperMesh.

1154 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATS1
Bulk Data Entry
MATS1 Stress-dependent and Temperature-dependent Material Definition
Description
Specifies stress-dependent and temperature-dependent material properties for use in
applications involving nonlinear materials. This entry is used if a MAT1 entry is specified with
the same MID in a nonlinear subcase.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATS1

MID

TID

TYPE

YF

HR

LIMIT1

(10)

TYPSTRN

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATS1

17

28

PLASTIC

0.0

2. + 4

Field

Contents

MID

Identification number of a MAT1 entry.

(9)

(10)

(Integer > 0)
TID

Identification number of a TABLES1 or TABLEST entry. If H is given, then


this field must be blank. See comment 3.
(Integer > 0 or blank)

TYPE

Type of material nonlinearity. See comments.


PLASTIC Elastoplastic material

Altair Engineering

OptiStruct 13.0 Reference Guide 1155


Proprietary Information of Altair Engineering

Field

Contents
NLELAST Nonlinear elastic material
Default = NLELAST (PLATIC, NLELAST)

Work hardening slope (slope of stress versus plastic strain) in units of stress.
For elastic-perfectly plastic cases, H = 0.0. For more than a single slope in
the plastic range, the stress-strain data must be supplied on a TABLES1
entry referenced by TID, and this field must be blank. See comment 2.
(Real > 0)

YF

Yield function criterion, selected by the following value (Integer):


1 = von Mises (Default)
(Integer > 0 or blank)

HR

Hardening Rule, selected by the following value (Integer):


1 = Isotropic Hardening (Default)
2 = Kinematic Hardening
3 = Mixed Hardening with 30% contribution of the Kinematic Hardening and
70% contribution of the Isotropic Hardening
Adjustable Mixed Hardening is selected by choosing (Real) value for HR:
0 < HR < 1 indicates a mixed combination of Isotropic and Kinematic
Hardening. The contribution of the Kinematic Hardening is HR whereas the
contribution of the Isotropic Hardening is 1 HR.
See comment 4.
(Integer 0, 1, 2, 3 or blank, or Real > 0 and < 1)

LIMIT1

Initial yield point. See comment 6.


(Real > 0 or Blank)

TYPSTRN

Specifies the type of strain used on the x-axis of the table pointed to by
TID. The strain type is selected by one of the following values. See
comment 5.
0 - total strain is used on the x-axis.
1 - plastic strain is used on the x-axis.
Default = 0 (Integer, 0, or 1)

1156 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

For nonlinear elastic material, the stress-strain data given in the TABLES1 entry will be
used to determine the stress for a given value of strain. The values H, YF, HR, and
LIMIT1 will not be used in this case. Nonlinear elastic material is only available in NLGEOM
subcases.

2.

For elastoplastic materials, the elastic stress-strain matrix is computed from a MAT1
entry, and the isotropic plasticity theory is used to perform the plastic analysis. In this
case, either the table identification TID or the work hardening slope H may be specified,
but not both. If the TID is omitted, the work hardening slope H must be specified unless
the material is perfectly plastic. The plasticity modulus (H) is related to the tangential
modulus (ET ) by

where, E is the elastic modulus and


curve in the plastic region.

is the slope of the uniaxial stress-strain

Stress-strain curve definition when H is specified in field 5.

3.

If TID is given, TABLES1 entries (Xi,Yi) of stress-strain data (


following rules:

) must conform to the

If TYPE = "PLASTIC", the curve must be defined in the first quadrant. The data points
must be in ascending order. If the table is defined in terms of total strain (TYPSTRN = 0),
the first point must be at the origin (X1 = 0, Y1 = 0) and the second point (X2, Y2) must
be at the initial yield point (Y 1) specified on the MATS1 entry. The slope of the line
joining the origin to the yield stress must be equal to the value of E. If the table is
defined in terms of plastic strain (TYPSTRN = 1), the first point (X1, Y1), corresponding to
yield point (Y 1), must be at X1=0. TID may reference a TABLEST entry. In this case, the
above rules apply to all TABLES1 tables pointed to by TABLEST.
If TYPE = NLELAST, the full stress-strain curve may be defined in the first and third
quadrants to accommodate different uniaxial compression data. If the curve is defined
only in the first quadrant, then the curve must start at the origin (X1 = 0.0, Y1 = 0.0).
For analyses where small deformations are assumed, there should be little or no difference

Altair Engineering

OptiStruct 13.0 Reference Guide 1157


Proprietary Information of Altair Engineering

between the true stress-strain curve and the engineering stress-strain curve, so either of
them may be used in the TABLES1 definition. For analyses where small deformations are
not assumed, the true stress-strain curve should be used.
If the deformations go past the values defined in the table, the curve is extrapolated
linearly.
4.

Kinematic hardening and Mixed hardening are supported only for solids.

5.

The conversion of the relation stress vs. total strain (TYPSTRN=0) into stress vs. plastic
strain (TYPSTRN=1) is illustrated below. This is clearly different than simply shifting the
entire table along the epsilon-axis.

1158 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

The LIMIT1 field can be blank if the initial yield point value is defined via a referenced
TABLES1 entry on the TID field. OptiStruct will error out if LIMIT1 is blank and TID does
not reference a TABLES1 entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1159


Proprietary Information of Altair Engineering

7.

The temperature-dependence of the MATS1 material is defined by referencing a TABLEST


entry via the TID field.

8.

Large strain elasto-plasticity can be activated using MATS1 (TYPE=PLASTIC) in


conjunction with PARAM, LGDISP, 1.

9.

Linear Buckling Analysis and Preloaded Analysis are not supported with models containing
nonlinear (MATS1) material entries. However, you can use PARAM,PRESUBNL,YES to force
OptiStruct to run in such models. Linear Buckling Analysis or Preloaded Analysis is not
recommended in models with nonlinear materials or in large displacement nonlinear
analysis. It is the users responsibility to interpret the results with caution.

1160 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATT1
Bulk Data Entry
MATT1 Isotropic Material Temperature Dependence
Description
Specifies temperature-dependent material properties on MAT1 entry fields via TABLEMi entries.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATT1

MID

T(E)

T(G)

T(NU)

T(RHO)

T(A)

T(ST)

T(SC )

T(SS)

(9)

(10)

T(GE)

Example

(1)

(2)

(3)

MATT1

17

32

(4)

(5)

(6)

(7)

(8)

(9)

(10)

15

52

Field

Contents

MID

Material property identification number that matches the identification number


on MAT1 entry.
(Integer > 0)

T(E)

Identification number of a TABLEMi entry for the Youngs modulus.


(Integer > 0 or blank)

T(G)

Identification number of a TABLEMi entry for the shear modulus.


(Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1161


Proprietary Information of Altair Engineering

Field

Contents

T(NU)

Identification number of a TABLEMi entry for the Poissons ratio.


(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEMi entry for the mass density.


(Integer > 0 or blank)

T(A)

Identification number of a TABLEMi entry for the thermal expansion


coefficient.
(Integer or blank)

T(GE)

Identification number of a TABLEMi entry for the damping coefficient.


(Integer > 0 or blank)

T(ST)

Identification number of a TABLEMi entry for the tension stress limit.


(Integer > 0 or blank)

T(SC)

Identification number of a TABLEMi entry for the compression limit.


(Integer > 0 or blank)

T(SS)

Identification number of a TABLEMi entry for the shear limit.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on, of this entry correspond, field-by-field, to fields 3, 4, and so on, of
the MAT1 entry referenced in field 2. The value in a particular field of the MAT1 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, E is modified; TABLEMi 32, A is modified by TABLEMi 15; and ST is
modified by TABLEMi 52. Blank or zero entries mean that there is no temperature
dependence of the field on the MAT1 entry.

2.

The MATT1 entries may refer to blank entries on the respective MAT1 card. In this case,
they will be applied to default values of respective parameters. Initial values of E, G, or
NU will be supplied according to comment 4 on the MAT1 entry.

3.

Table references must be present for each item that is temperature dependent. For
example, it is not sufficient to only give table references for fields 3 and 4 (Youngs
modulus and shear modulus) if Poissons ratio is temperature dependent.

4.

The TEMPERATURE subcase information entry (with type = MATERIAL) is required to

1162 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

activate temperature-dependent material behavior and to define the temperature field


(option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).
5.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1163


Proprietary Information of Altair Engineering

MATT2
Bulk Data Entry
MATT2 Anisotropic Material Temperature Dependence
Description
Specifies temperature-dependent material properties on MAT2 entry fields via TABLEMj
entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATT2

MID

T(G11)

T(G12)

T(G13)

T(G22)

T(G23)

T(G33)

T(RHO)

T(A1)

T(A2)

T(A3)

T(GE)

T(ST)

T(SC )

T(SS)

Example

(1)

(2)

(3)

MATT2

17

32

(4)

(5)

(6)

(7)

(8)

(9)

(10)

15

62

Field

Contents

MID

Material property identification number that matches the identification number


on a MAT2 entry.
(Integer > 0)

T(Gij)

Identification number of a TABLEMk entry for the terms in the material


property matrix.
(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEMk entry for the mass density.

1164 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Integer > 0 or blank)

T(Ai)

Identification number of a TABLEMk entry for the thermal expansion


coefficient.
(Integer or blank)

T(GE)

Identification number of a TABLEMk entry for the damping coefficient.


(Integer > 0 or blank)

T(ST)

Identification number of a TABLEMk entry for the tension stress limit.


(Integer > 0 or blank)

T(SC)

Identification number of a TABLEMk entry for the compression limit.


(Integer > 0 or blank)

T(SS)

Identification number of a TABLEMk entry for the shear limit.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT2 entry referenced in field 2. The value in a particular field of the MAT2 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, G11 is modified by TABLEMk 32; G33 is modified by TABLEMk 15; and
A1 is modified by TABLEMk 62. If Ri is zero or blank, there is no temperature dependence
of the field on the MAT2 entry.

2.

The MATT2 entries may refer to blank entries on the respective MAT2 card. In which
case, they will be applied to default values of respective parameters.

3.

The TEMPERATURE subcase information entry (with type = MATERIAL) is required to


activate temperature-dependent material behavior and to define the temperature field
(option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).

4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1165


Proprietary Information of Altair Engineering

MATT3
Bulk Data Entry
MATT3 MAT3 Material Temperature Dependence
Description
Specifies temperature-dependent material properties on MAT3 entry fields via TABLEMi entries.

Format
(1)

(2)

(3)

(4)

(5)

MATT3

MID

T(EX)

T(ETH)

T(EZ)

T(GZX)

T(AX)

(6)

(7)

(8)

(9)

(10)

T(NUXTH) T(NUTHZ) T(NUZX) T(RHO)

T(ATH)

T(AZ)

T(GE)

Example

(1)

(2)

(3)

MATT3

17

32

(4)

(5)

(6)

(7)

(8)

(9)

(10)

19

52

Field

Contents

MID

Material property identification number that matches the identification


number on MAT3 entry.
(Integer > 0)

T(EX),
T(ETH),
T(EZ)

Identification number of a TABLEMi entry for the Youngs moduli in the x,


and z directions.
Default = blank (Integer > 0 or blank)

T(NUXTH), Identification number of a TABLEMi entry for the Poissons ratios in the x, z

1166 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(NUTHZ), and zx directions.


T(NUZX)
Default = blank (Integer > 0 or blank)
T(RHO)

Identification number of a TABLEMi entry for the mass density.


Default = blank (Integer > 0 or blank)

T(GZX)

Identification number of a TABLEMi entry for the shear modulus.


Default = blank (Integer > 0 or blank)

T(AX),
T(ATH),
T(AZ)

Identification number of a TABLEMi entry for the thermal expansion


coefficients in the x, and z directions.
Default = blank (Integer or blank)

T(GE)

Identification number of a TABLEMi entry for the damping coefficient.


Default = blank (Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on, of this entry correspond, field-by-field, to fields 3, 4, and so on, of
the MAT3 entry referenced in field 2. The value in a particular field of the MAT3 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, EX is modified; TABLEMi 32, EZ is modified by TABLEMi 19; and GZX is
modified by TABLEMi 52. Blank or zero entries mean that there is no temperature
dependence of the field on the MAT3 entry.

2.

Any quantity modified by this entry must have a value on the MAT3 entry.

3.

The TEMPERATURE subcase information entry (with type = MATERIAL) is required to


activate temperature-dependent material behavior and to define the temperature field
(option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).

4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1167


Proprietary Information of Altair Engineering

MATT4
Bulk Data Entry
MATT4 Temperature-Dependent Material Property Definition, Form 4
Description
Defines temperature-dependent material properties for the corresponding MAT4 bulk data
entry fields via TABLEMi entries.
Format
(1)

(2)

(3)

MATT4

MID

T(K)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

MATT4

24

200

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Field

Contents

MID

Material identification number of a MAT4 bulk data entry that is temperature


dependent.
No default (Integer > 0)

T(K)

Identification number of a TABLEMi entry that defines temperature-dependent


thermal conductivity.
Default = 0 (Integer > 0)

Comments
1.

The quantities defined on the MAT4 bulk data entry are multiplied by the tabular function
referenced by the MATT4 bulk data card to generate the corresponding material
properties.

2.

If the fields are blank or zero, then constant properties defined on the MAT4 bulk data
card are used.

1168 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATT8
Bulk Data Entry
MATT8 Shell Orthotropic Material Temperature Dependence
Description
Specifies temperature-dependent material properties on MAT8 entry fields via TABLEMi entries.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATT8

MID

T(E1)

T(E2)

T(NU12)

T(G12)

T(G1Z)

T(G2Z)

T(RHO)

T(A1)

T(A2)

T(Xt)

T(Xc)

T(Yt)

T(Yc)

T(S)

T(GE)

T(F12)

Example

(1)

(2)

(3)

MATT8

17

32

(4)

15

(5)

(6)

(7)

(8)

(9)

(10)

15

52

Field

Contents

MID

Material property identification number that matches the identification


number on MAT1 entry.
(Integer > 0)

T(E1)

Identification number of a TABLEMi entry for the Youngs modulus 1.


(Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1169


Proprietary Information of Altair Engineering

Field

Contents

T(E2)

Identification number of a TABLEMi entry for the Youngs modulus 2.


(Integer > 0 or blank)

T(NU12)

Identification number of a TABLEMi entry for the Poissons ratio 12.


(Integer > 0 or blank)

T(G12)

Identification number of a TABLEMi entry for shear modulus 12.


(Integer > 0 or blank)

T(G1Z)

Identification number of a TABLEMi entry for transverse shear modulus 1Z.


(Integer > 0 or blank)

T(G2Z)

Identification number of a TABLEMi entry for transverse shear modulus 2Z.


(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEMi entry for mass density.


(Integer > 0 or blank)

T(A1)

Identification number of a TABLEMi entry for the thermal expansion


coefficient 1. See comment 3.
(Integer or blank)

T(A2)

Identification number of a TABLEMi entry for the thermal expansion


coefficient 2.
(Integer or blank)

T(Xt)

Identification number of a TABLEMi entry for the tension stress/strain limit 1.


(Integer > 0 or blank)

T(Xc)

Identification number of a TABLEMi entry for compression stress/strain limit


1.
(Integer > 0 or blank)

1170 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(Yt)

Identification number of a TABLEMi entry for tension stress/strain limit 2.


(Integer > 0 or blank)

T(Yc)

Identification number of a TABLEMi entry for compression stress/strain limit


2.
(Integer > 0 or blank)

T(S)

Identification number of a TABLEMi entry for shear stress/strain limit.


(Integer > 0 or blank)

T(GE)

Identification number of a TABLEMi entry for structural damping coefficient.


(Integer > 0 or blank)

T(F12)

Identification number of a TABLEMi entry for Tsai-Wu interaction term.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT8 entry referenced in field 2. The value in a particular field of the MAT8 entry is
replaced or modified by the table referenced in the corresponding field of this entry. In
the example shown, E1 is modified by TABLEMi 32; A1 is modified by TABLEMi 15; and Xt
is modified by TABLEMi 52. Blank or zero entries mean that there is no temperature
dependence of the fields on the MAT8 entry.

2.

The MATT8 entries may refer to blank entries on the respective MAT8 card. In which
case, they will be applied to default values of respective parameters.

3.

The TEMPERATURE subcase information entry (with type = MATERIAL) is required to


activate temperature-dependent material behavior and to define the temperature field
(option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).

4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1171


Proprietary Information of Altair Engineering

MATT9
Bulk Data Entry
MATT9 Solid Element Anisotropic Material Temperature Dependence
Description
Specifies temperature-dependent material properties on MAT9 entry fields via TABLEMk
entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATT9

MID

T(G11)

T(G12)

T(G13)

T(G14)

T(G15)

T(G16)

T(G22)

T(G23)

T(G24)

T(G25)

T(G26)

T(G33)

T(G34)

T(G35)

T(G36)

T(G44)

T(G45)

T(G46)

T(G55)

T(G56)

T(G66)

T(RHO)

T(A1)

T(A2)

T(A3)

T(A4)

T(A5)

T(A6)

T(GE)

Example

(1)

(2)

(3)

MATT9

17

32

(4)

(5)

(6)

(7)

(8)

18

(9)

(10)

17

12

10

Field

Contents

MID

Material property identification number that matches the identification number


on a MAT9 entry.
(Integer > 0)

1172 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

T(Gij)

Identification number of a TABLEMk entry for the terms in the material


property matrix.
(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEMk entry for the mass density.


(Integer > 0 or blank)

T(Ai)

Identification number of a TABLEMk entry for the thermal expansion


coefficients.
(Integer > 0 or blank)

T(GE)

Identification number of a TABLEMk entry for the damping coefficient.


(Integer > 0 or blank)

Comments
1.

Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of


the MAT9 entry referenced in field 2. The value recorded in a particular field of the MAT9
entry is replaced or modified by the table referenced in the corresponding field of this
entry. In the example shown, G11 is modified by TABLEMj 32; G14 is modified by TABLEMj
18, and so on. If the fields are zero or blank, there is no temperature dependence of the
field on the MAT9 entry.

2.

The MATT9 entries may refer to blank entries on the respective MAT9 card. In which
case, they will be applied to default values of respective parameters.

3.

The continuation entries are optional.

4.

The TEMPERATURE subcase information entry (with type = MATERIAL) is required to


activate temperature-dependent material behavior and to define the temperature field
(option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).

5.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1173


Proprietary Information of Altair Engineering

MATX0
Bulk Data Entry
MATX0 Material Property Extension for Void Material for Geometric Nonlinear Analysis
Description
Defines void material for geometric nonlinear analysis.
Format
(1)

(2)

(3)

MATX0

MID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

MAT1

102

10.0

MATX0

102

(4)

(5)

(6)

0.495

6.0E-10

(7)

Field

Contents

MID

Material ID of the associated MAT1. See comment 1.

(8)

(9)

(10)

No default (Integer > 0)


Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATX0 material extension can be associated with a particular MAT1.

2.

MATX0 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN subcase entry. For all other subcases, it is
treated as an elastic material defined by the associated MAT1.

3.

This card is represented as an extension to a MAT1 material in HyperMesh.

1174 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX02
Bulk Data Entry
MATX02 Material Property Extension for Johnson-Cooke Elastic-plastic Material for
Geometric Nonlinear Analysis
Description
Defines additional material properties for Johnson-Cooke elastic-plastic material for geometric
nonlinear analysis. This is an elasto-plastic law with strain rate and temperature effects.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATX02

MID

EPSMAX

SIGMAX

DEPS0

IC C

FSMOOTH

FC UT

TMELT

RC P

(10)

Example

(1)

(2)

(3)

MAT1

102

60.4

MATX02

102

0.09026

(4)

0.22313

(5)

(6)

0.33

2.70E-06

0.374618

100.0

(7)

(8)

(9)

(10)

0.175

Field

Contents

MID

Material ID of the associated MAT1. See comment 1.


No default (Integer > 0)

Plasticity yield stress.


(Real > 0)

Plasticity hardening parameter.


(Real > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1175


Proprietary Information of Altair Engineering

Field

Contents

Plasticity hardening exponent.


Default = 1.0 (Real < 1.0)

EPSMAX

Failure plastic strain max


Default = 1030 (Real > 0)

SIGMAX

Maximum plastic stress max0


Default = 1030 (Real > 0)

Strain rate coefficient. If zero, there is no strain rate effect.


Default = 0.0 (Real)

DEPS0

Reference strain rate

Default = 0.0 (Real)


If DESPS < DESPS0, no strain rate effect.
ICC

Flag for strain rate dependency of max (See comment 5).


Default = ON (ON or OFF)

FSMOOTH

Flag for strain rate smoothing.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering. Only for shell and solid elements.
Default = 1030 (Real > 0)

Temperature exponent.
Default = 0.0 (Real)

TMELT

Melting temperature.
Default = 1030 (Real > 0)

1176 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

RCP

Specific heat per unit of volume.


Default = 0.0 (Real > 0)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX02 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This is an elastic-plastic law with strain rate and thermal effects. It follows:

with:

= plastic strain
= strain rate
T = Temperature (in Kelvin)
4.

If the plastic strain reaches EPSMAX, shell elements are deleted. Solid elements are not
deleted, but the deviatoric stress is set to zero.

5.

ICC controls the strain rate effect.

Altair Engineering

OptiStruct 13.0 Reference Guide 1177


Proprietary Information of Altair Engineering

6.

No strain rate effects are considered in rod elements.

7.

Strain rate filtering is used to smooth strain rates. The input FCUT is available only for
shell and solid elements.

8.

To take into account the temperature effect, strain rate dependence must be activated.
If the temperature exponent M = 0; there is no temperature effect. No temperature
effect is considered on rod, bar, and beam elements.

9.

The temperature is computed assuming adiabatic conditions:

where, Eint is the internal energy.


If Cp = 0, the temperature is constant: T = T i
10. This card is represented as an extension to a MAT1 material in HyperMesh.

1178 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX13
Bulk Data Entry
MATX13 Material Property Extension for Rigid Material for Geometric Nonlinear Analysis
Description
Defines rigid material for geometric nonlinear analysis.
Format
(1)

(2)

(3)

MATX13

MID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

MAT1

102

10.0

MATX13

102

(4)

(5)

(6)

0.495

6.0E-10

(7)

Field

Contents

MID

Material ID of the associated MAT1. See comment 1.

(8)

(9)

(10)

No default (Integer > 0)


Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX13 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1179


Proprietary Information of Altair Engineering

MATX21
Bulk Data Entry
MATX21 Material Property Extension for Rock-Concrete Material for Geometric Nonlinear
Analysis
Description
Defines additional material properties for Rock-Concrete material for geometric nonlinear
analysis. This law is based on the Drcker-Prager yield criteria and is used to model materials
with internal friction such as rock-concrete. The plastic behavior of these materials is
dependent on the pressure in the material. This law is only applicable to solid elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MATX21

MID

A0

A1

A2

AMAX

TPID

KT

FSC AL

PMIN

(7)

(8)

(9)

MUMAX

PEXT

(10)

Example

(1)

(2)

(3)

MAT1

102

3.1E10

MATX21

102
1

(4)

(5)

(6)

0.33

1000.0

(7)

(8)

(9)

(10)

3
1E10

Field

Contents

MID

Material ID of the associated MAT1. See comment 1.


No default (Integer > 0)

A0

Coefficient.
(Real)

1180 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

A1

Coefficient.
(Real)

A2

Coefficient.
(Real)

AMAX

Von Mises limit.


Default = 1030 (Real > 0)

TPID

Identification number of a TABLES1 that defines the volumetric strain vs.


pressure function.
No default (Integer > 0)

KT

Tensile bulk modulus.


(Real > 0.0)

FSCAL

Scale factor for pressure function.


Default = 1.0 (Real)

PMIN

Minimum pressure.
Default = -1030 (Real)

Unloading bulk modulus.


(Real > 0.0)

MUMAX

Maximum compression volumetric strain.


(Real)

PEXT

External pressure (see comment 6).


Default = 0.0 (Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATX21 material extension can be associated with a particular MAT1.

2.

MATX21 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide 1181


Proprietary Information of Altair Engineering

3.

Hydrodynamic behavior is given by a user-defined function P = f()


where, P is the pressure in the material, and is the volumetric strain.

4.

Drcker-Prager yield criteria uses a modified von Mises yield criteria to incorporate the
effects of pressure for massive structures:
F = J2 - (A0 + A1P + A2P2)
where,
J2: second invariant of deviatoric stress.
P: pressure.
A0, A1, A2: material coefficients.
A1 = A2 = 0 means that the yield criteria is von Mises (

vm

3 A0

1182 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

It is recommended to set unloading bulk modulus, B equal to the initial slope of function
describing P() and tensile bulk modulus KT equal to 1/100 of unloading bulk modulus. B
and KT must be positive.

6.

External pressure is required if relative pressure formulation is used. In this specific case,
yield criteria and energy integration require the value of total pressure.

7.

This card is represented as an extension to a MAT1 material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1183


Proprietary Information of Altair Engineering

MATX25
Bulk Data Entry
MATX25 Material Property Extension for Tsai-Wu and CRASURVT Materials for Geometric
Nonlinear Analysis
Description
Defines an elasto-plastic orthotropic material with Tsai-Wu and CRASURVT yield criteria for
composite shell materials.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATX25

MID

EPSF1

EPSF2

EPST1

EPSM1

EPST2

EPSM2

DTENDS

WPMAX

WPREF

IOFF

GAMINI

GAMMAX

DMAX

RATIO

FSMOOTH

FC UT

IFORM

(10)

Continuation line for IFORM = TSAI


B

FMAX

SY1T

SY2T

SY1C

SY2C

ALFA

SY12C

SY12T

C 12

EPSR0

IC C

Continuation line for IFORM = CRAS


C

EPSR0

ALFA

IC C G

SY1T

B1T

N1T

SMAX1T

EPS1T1

EPS2T1

SRST1

WMPT1

SY2T

B2T

N2T

SMAX2T

EPS1T2

EPS2T2

SRST2

WMPT2

C 1T

C 2T

1184 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SY1C

B1C

N1C

SMAX1C

EPS1C 1

EPS2C 1

SRSC 1

WMPC 1

SY2C

B2C

N2C

SMAX2C

EPS1C 2

EPS2C 2

SRSC 2

WMPC 2

SY12T

B12T

N12T

SMAX12
T

EPS1T12

EPS2T12

SRST12

WMPT12

C 1C

C 2C

C 12T

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MAT8

102

70000

70000

0.3

26923.1

26923.1

26923.1

MATX25

102

0.15

0.2

(9)

(10)

0.95

0.2

1.0

2.0

1E10

1E10

1E10

1E10

1E10

1E10

Field

Contents

MID

Material ID of the associated MAT8. See comment 1.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1185


Proprietary Information of Altair Engineering

Field

Contents

EPSF1

Total tensile failure in direction 1.


Default = 1E30 (Real)

EPSF2

Total tensile failure in direction 2.


Default = 1E30 (Real)

EPST1

Tensile failure strain in direction 1.


(Real)

EPSM1

Maximum strain in direction 1.


(Real)

EPST2

Tensile failure strain in direction 2.


(Real)

EPSM2

Maximum strain in direction 2.


(Real)

DTENDS

Maximum damage of composite tensile strength.


Default = 0.999 (Real < 1.0)

WPMAX

Maximum plastic work.


Default = 1E30 (Real)

WPREF

Reference plastic work.


Default = 1.0 (Real)

IOFF

Total element failure criteria.


Default = 0 (Integer)
= 0: shell is deleted if Wp* > Wp*max for 1 layer
= 1: shell is deleted if Wp* > Wp*max for all layers
= 2: if for each layer, Wp* > Wp*max or tensile failure in direction 1(t1)

1186 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
= 3: if for each layer, Wp* > Wp*max or tensile failure in direction 2(t2)
= 4: if for each layer, Wp* > Wp*max or tensile failure in directions 1(t1) and
2(t2)
= 5: if for all layers: Wp* > Wp*max or tensile failure in direction 1(t1)
or if for all layers: Wp* > Wp*max or tensile failure in direction 2(t2)
= 6: if for each layer, Wp* > Wp*max or tensile failure in direction 1(t1) or
2(t2)

GAMINI

Delamination shear strain. See comment 11.


Default = 1E30 (Real)

GAMMAX

Maximum shear strain.


Default = 1.1E30 (Real)

DMAX

Maximum damage.
Default = 1.0 (Real)

RATIO

Ratio parameter control to delete shell elements


Default = 1.0 (Real)
< 0.0: the element will be deleted if all of the layers but one fail (the number
of layers that did not fail is equal to 1).
> 0.0: the element will be deleted if:

FSMOOTH

Flag for strain rate smoothing.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering.


Default = 1E30 (Real)

IFORM

Formulation flag.
Default = TSAI (TSAI, CRAS)

IFORM = TSAI

Altair Engineering

OptiStruct 13.0 Reference Guide 1187


Proprietary Information of Altair Engineering

Field

Contents

Hardening parameter.
(Real)

Hardening exponent.
Default = 1.0 (Real)

FMAX

Maximum value of yield function.


Default = 1E30 (Real)

SY1T

Tension in direction 1.
(Real > 0)

SY2T

Tension in direction 2.
(Real > 0)

SY1C

Compression yield stress in direction 1.


(Real > 0)

SY2C

Compression yield stress in direction 2.


(Real > 0)

ALFA

F12 reduction factor.


Default = 1.0 (Real)

SY12C

Compression yield stress in direction 12.


(Real > 0)

SY12T

Tension yield stress in direction 12.


(Real > 0)

C12

Strain rate coefficient.


(Real)

1188 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
= 0.0: no strain rate dependency.

EPSR0

Reference strain rate.


(Real)

ICC

Flag for yield stress in shear and strain rate (See comment 9).
(Integer)
= 0:
= 1:
= 2:
= 3:
= 4:

Default set to 1
Strain rate effect on FMAX no effect on WPMAX
No strain rate effect on FMAX and WPMAX
Strain rate effect on FMAX and WPMAX
No strain rate effect on FMAX effect on WPMAX

IFORM = CRAS
C

Global strain rate coefficient for plastic work criteria.


(Real)

EPSR0

Reference strain rate.


(Real)

ALFA

F12 reduction factor.


Default= 1.0 (Real)

ICCG

Global composite plasticity parameters flag for strain rate computation: (See
comment 9).
= 1: Strain rate effect on SMAX1T, SMAX2T, SMAX1C, SMAX2C, SMAX12T;
no strain rate effect on WPMAX.
= 2: No strain rate effect on SMAX1T, SMAX2T, SMAX1C, SMAX2C,
SMAX12T; no strain rate effect on WPMAX.
= 3: Strain rate effect on SMAX1T, SMAX2T, SMAX1C, SMAX2C, SMAX12T
and strain rate effect on WPMAX.
= 4: No strain rate effect on SMAX1T, SMAX2T, SMAX1C, SMAX2C, SMAX12T
and strain rate effect on WPMAX.
Default = 1 (Integer)

Altair Engineering

OptiStruct 13.0 Reference Guide 1189


Proprietary Information of Altair Engineering

Field

Contents

SY1T

Tension yield stress in direction 1.


(Real > 0)

B1T

Hardening parameter in direction 1.


(Real)

N1T

Hardening exponent in direction 1.


Default = 1.0 (Real)

SMAX1T

Maximum stress in direction 1.


Default = 1E30 (Real)

C1T

Strain rate coefficient in direction 1.


0: no strain rate dependency.
Default = C (Real)

EPS1T1

Initial softening strain in direction 1.


Default = 1E30 (Real)

EPS2T1

Maximum softening strain in direction 1.


Default = 1.2 * EPS1T1 (Real)

SRST1

Residual stress in direction 1.


Default = 10E-3*SY1T (Real)

WMPT1

Maximum plastic work in tension direction 1.


Default = 1E30 (Real)

SY2T

Tension yield stress in direction 2.


(Real > 0)

B2T

Hardening parameter in direction 2.

1190 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = B1T (Real)

N2T

Hardening exponent in direction 2.


Default = N1T (Real)

SMAX2T

Maximum stress in direction 2.


Default = 1E30 (Real)

C2T

Strain rate coefficient in direction 2.


0: no strain rate dependency
Default = C (Real)

EPS1T2

Initial softening strain in direction 2.


Default = 1E30 (Real)

EPS2T2

Maximum softening strain in direction 2.


Default = 1.2*EPS1T1 (Real)

SRST2

Residual stress in direction 2.


Default = 10E-3 * SY2T (Real)

WMPT2

Maximum plastic work in tension direction 2.


Default = 1E30 (Real)

SY1C

Compression yield stress in direction 1.


(Real > 0)

B1C

Hardening parameter in direction 1.


Default = B2T (Real)

N1C

Hardening exponent in direction 1.


Default = N2T (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1191


Proprietary Information of Altair Engineering

Field

Contents

SMAX1C

Maximum stress in direction 1.


Default = 1E30 (Real)

C1C

Strain rate coefficient in direction 1.


= 0.0: no strain rate dependency.
Default = C (Real)

EPS1C1

Initial softening strain in direction 1.


Default = 1E30 (Real)

ESP2C1

Maximum softening strain in direction 1.


Default = 1.2*EPS1C1 (Real)

SRSC1

Residual stress in direction 1.


Default = 10E-3*S1YC (Real)

WMPC1

Maximum plastic work in compression direction 1.


Default = 1E30 (Real)

SY2C

Compression yield stress in direction 2.


(Real > 0)

B2C

Hardening parameter in direction 2.


Default = B1C (Real)

N2C

Hardening exponent in direction 2


Default = N1C (Real)

SMAX2C

Maximum stress in direction 2.


Default = 1E30 (Real)

C2C

Strain rate coefficient in direction 2.

1192 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
= 0.0: no strain rate dependency.
Default = C (Real)

EPS1C2

Initial softening strain in direction 2.


Default = 1E30 (Real)

EPS2C2

Maximum softening strain in direction 2.


Default = 1.2*EPS1C2 (Real)

SRSC2

Residual stress in direction 2.


Default = 10E-3*S2YC (Real)

WMPC2

Maximum plastic work in compression direction 2.


Default = 1E30 (Real)

SY12T

Tension yield stress in direction 12.


(Real > 0)

B12T

Hardening parameter in direction 12.


Default = B2C (Real)

N12T

Hardening exponent in direction 12.


Default = 1.0 (Real)

SMAX12T

Maximum stress in direction 12.


Default = 1E30 (Real)

C12T

Strain rate coefficient in direction 12.


= 0.0: no strain rate dependency.
Default = C (Real)

EPS1T12

Initial softening strain in direction 12.

Altair Engineering

OptiStruct 13.0 Reference Guide 1193


Proprietary Information of Altair Engineering

Field

Contents
Default = 1E30 (Real)

EPS2T12

Maximum softening strain in direction 12.


Default = 1.2*EPS1T12 (Real)

SRST12

Residual stress in direction 12.


Default = 10E-3*SY12T (Real)

WMPT12

Maximum plastic work in shear.


Default = 1E30 (Real)

Comments
1.

The material identification number must be that of an existing MAT8 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT8.

2.

MATX25 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

Tsai-Wu formula (IFORM=TSAI) is not available with QEPH (ISHELL=24 on PCOMPX) shell
elements, it is only available with Q4 (ISHELL=1,2,3,4 on PCOMPX) and QBAT(ISHELL=12
on PCOMPX) shell elements.

4.

The Lamina yield surface for Tsai-Wu criteria(IFORM=TSAI) is:

with:
Wp is the plastic work
is the reference plastic work

is the yield envelope evolution:


where,
b = Hardening parameter for plastic work
n = Hardening exponent

1194 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

The CRASURV model is an improved version of the former law based on the standard TsaiWu criteria. The main changes concern the expression of the yield surface before
plastification and during work hardening. Firstly, in a CRASURV model, the coefficient F 44
depends only on one input parameter:

Another modification concerns the parameters F ij which are expressed now in function of
plastic work and plastic work rate as below:

6.

If the total tensile failure value EPSF1 is reached in the direction 1 and respectively
EPSF2 in the direction 2, the stresses tensor in the layer is permanently reset to 0.

Altair Engineering

OptiStruct 13.0 Reference Guide 1195


Proprietary Information of Altair Engineering

7.

If a shell has several layers with one material per layer (different materials, different
IOFF), the IOFF used is the one that is associated to the shell in the shell element
definition.

8.

Both Wp* and Wp*max are defined as follows:

9.

The plastic work criteria is:

When ICC=2,3,4 for Tsai-Wu formula, when ICCG=3,4 for CRASURV formula.
10. Delamination is a global model:

with

applies to the all shell and not independently per each layer.

11. Thereby, the coefficients GAMINI, GAMMAX, and DMAX considered, are the coefficients
which are defined in the global material associated to the shell equivalent out-of-plane
shear strain.
12. The IOFF and RATIO field values are utilized only if they are defined in the material
assigned to a part, these fields are not considered if they are only defined in material
used for a layer in the property entry. This option is not available for solid elements.
13. This card is represented as extension to a MAT8 material in HyperMesh.

1196 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX27
Bulk Data Entry
MATX27 Material Property Extension for Elastic-Plastic Brittle Material for Geometric
Nonlinear Analysis
Description
Defines additional material properties for elastic-plastic brittle material for geometric nonlinear
analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATX27

MID

EPSMAX

SIGMAX

DEPS0

EPS1MAX

D1MAX

EPSD1

EPS2

EPS2MAX

D2MAX

ESPD2

IC C

EPS1

Example

(1)

(2)

(3)

MAT1

127

60.4

MATX27

127

0.09026

(4)

0.22313

(5)

(6)

0.33

2.70E-06

0.374618

100.0

(7)

(8)

(9)

(10)

0.175

Field

Contents

MID

Material ID of the associated MAT1. See comment 1.


No default (Integer > 0)

Plasticity yield stress.


(Real > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1197


Proprietary Information of Altair Engineering

Field

Contents

Plasticity hardening parameter.


(Real > 0)

Plasticity hardening exponent.


Default = 1.0 (Real < 1.0)

EPSMAX

Failure plastic strain max


Default = 1030 (Real > 0)

SIGMAX

Maximum plastic stress max0


Default = 1030 (Real > 0)

Strain rate coefficient.


Default = 0.0 (Real)

DEPS0

Reference strain rate

Default = 0.0 (Real)


If DESPS < DESPS0, no strain rate effect.
ICC

Flag for strain rate dependency of max . See comment 4.


Default = ON (ON or OFF)

EPS1

Tensile failure strain in principal strain direction 1.


Default = 1.0*1030

EPS1MAX

Maximum tensile failure strain in principal strain direction 1.


Default = 1.1*1030

DMAX1

(Real > 0)

(Real > 0)

Maximum tensile failure damage in principal strain direction 1.


Default = 0.999 (Real > 0)

1198 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EPSD1

Tensile strain for element deletion in principal strain direction 2.


Default = 1.2*1030 (Real > 0)

EPS2

Tensile failure strain in principal strain direction 2.


Default = 1.0*1030

EPS2MAX

Maximum tensile failure strain in principal strain direction 2.


Default = 1.1*1030

DMAX2

(Real > 0)

(Real > 0)

Maximum tensile failure damage in principal strain direction 2.


Default = 0.999 (Real > 0)

EPSD2

Tensile strain for element deletion in principal strain direction 2.


Default = 1.2*1030

(Real > 0)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX27 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This law is only applicable with shell elements. The isotropic elasto-plastic model is the
same as with MATX02. However, MATX27 allows material damage and brittle failure to be
modeled.

4.

ICC controls the strain rate effect.

Altair Engineering

OptiStruct 13.0 Reference Guide 1199


Proprietary Information of Altair Engineering

5.

The failure plastic strain EPSMAX has no effect if the second continuation is defined.

6.

An element is removed if one layer reaches the tensile failure strain EPS1.

7.

This card is represented as an extension to a MAT1 material in HyperMesh.

1200 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX28
Bulk Data Entry
MATX28 Material Property Extension for Honeycomb Material for Geometric Nonlinear
Analysis
Description
Defines additional material properties for Honeycomb material for geometric nonlinear analysis.
This law is only applicable to solid elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATX28

MID

(9)

TIID11

TIID22

TIID33

IFLAG1

FSC AI11

FSC AI22

FSC AI33

EPSFI11

EPSFI22

EPSFI33

TIID12

TIID23

TIID31

IFLAG2

FSC AI12

FSC AI23

FSC AI31

EPSFI12

EPSFI23

EPSFI31

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT9ORT

102

0.2

0.02

0.02

0.33

0.33

0.33

0.286E-7

0.1

0.01

0.1

11

22

33

NEGSTR

1.0

1.0

1.0

12

23

31

NEGSTR

1.0

1.0

1.0

MATX28

(10)

102

Altair Engineering

OptiStruct 13.0 Reference Guide 1201


Proprietary Information of Altair Engineering

0.0

0.0

0.0

Field

Contents

MID

Material ID of the associated MAT9ORT. See comment 1.


No default (Integer > 0)

TIID11

Identification number of a TABLES1 that defines the initial yield stress function
in direction 11.
No default (Integer > 0)

TIID22

Identification number of a TABLES1 that defines the initial yield stress function
in direction 22.
No default (Integer > 0)

TIID33

Identification number of a TABLES1 that defines the initial yield stress function
in direction 33.
No default (Integer > 0)

IFLAG1

Strain formulation for yield functions 11, 22, and 33. See comment 4.
Default = VOLSTR (VOLSTR, STR, or NEGSTR)
VOLSTR - Yield stress is a function of volumetric strains.
STR - Yield stress is a function of strains.
NEGSTR - Yield stress is a function of negative strains.

FSCAI11

Scale factor on initial yield stress function in direction 11.


Default = 1.0 (Real)

FSCAI22

Scale factor on initial yield stress function in direction 22.


Default = 1.0 (Real)

FSCAI33

Scale factor on initial yield stress function in direction 33.


Default = 1.0 (Real)

EPSFI11

Initial failure strain under tension or compression in direction 11.


(Real)

EPSFI22

Initial failure strain under tension or compression in direction 22.

1202 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Real)

EPSFI33

Initial failure strain under tension or compression in direction 33.


(Real)

TIID12

Identification number of a TABLES1 that defines the initial shear yield stress
function in direction 12.
No default (Integer > 0)

TIID23

Identification number of a TABLES1 that defines the initial shear yield stress
function in direction 23.
No default (Integer > 0)

TIID31

Identification number of a TABLES1 that defines the initial shear yield stress
function in direction 31.
No default (Integer > 0)

IFLAG2

Strain formulation for yield functions 12, 23, and 31.


Default = VOLSTR (VOLSTR, STR, or NEGSTR)
VOLSTR - Yield stress is a function of volumetric strains.
STR - Yield stress is a function of strains.
NEGSTR - Yield stress is a function of negative strains.

FSCAI12

Scale factor on initial shear yield stress function in direction 12.


Default = 1.0 (Real)

FSCAI23

Scale factor on initial shear yield stress function in direction 23.


Default = 1.0 (Real)

FSCAI31

Scale factor on initial shear yield stress function in direction 31.


Default = 1.0 (Real)

EPSFI12

Initial failure strain under tension or compression in direction 12.


(Real)

EPSFI23

Initial failure strain under tension or compression in direction 23.


(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1203


Proprietary Information of Altair Engineering

Field

Contents

EPSFI31

Initial failure strain under tension or compression in direction 31.


(Real)

Comments
1.

The material identification number must be that of an existing MAT9ORT bulk data entry.
Only one MATX28 material extension can be associated with a particular MAT9ORT.

2.

MATX28 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This law is compatible with 10 node tetrahedron elements, and it is compatible with
ISOLID = 1, 2, or 12 on PSOLIDX card.

4.

This law is not compatible with IFRAME = OFF, if it is referenced by the PSOLIDX card.

5.

When switching from a volumetric strain formulation to a strain formulation, IFLAGi =


NEGSTR allows the same function definition to be retained.

6.

If one of the failure or shear failure strains is reached, the element is deleted.

7.

Transition strains define transition from initial yield stress function to residual yield stress
function.

8.

If one of the transition or shear transition strains is reached, the element has yield stress
described by residual functions in each direction. Transition is applied to the neighboring
elements.

9.

This card is represented as an extension to a MAT9ORT material in HyperMesh.

1204 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX33
Bulk Data Entry
MATX33 Material Property Extension for Visco-Elastic Plastic Foam Material for Geometric
Nonlinear Analysis
Description
Defines additional material properties for visco-elastic plastic foam material for geometric
nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATX33

MID

KA

TID

FSC ALE

P0

PHI

EPSV0

E1

E2

ET

ETAC

(10)

ETAS

Example

(1)

(2)

(3)

MAT1

133

0.11

MATX33

133

(4)

(5)

(6)

0.11

9.92E-07

(7)

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).

(8)

(9)

(10)

No default (Integer > 0)


KA

Flag for analysis type.


Default = ELAST (Character = ELAST, VISCO)
ELAST: the skeletal behavior before yield is elastic.
VISCO: the skeletal behavior before yield is visco-elastic.

Altair Engineering

OptiStruct 13.0 Reference Guide 1205


Proprietary Information of Altair Engineering

Field

Contents

TID

Identification number of TABLES1 entry that defines the yield stress vs.
volumetric strain curve.
No default (Integer > 0)

FSCALE

Scale factor for stress in yield curve.


Default = 1.0 (Real)

P0

Initial air pressure (See comment 4).


Default = 0.0 (Real)

PHI

Ratio of foam to polymer density.


Default = 0.0 (Real)

EPSV0

Initial volumetric strain.


Default = 0.0 (Real)

Yield parameter.
Default = 0.0 (Real)

Yield parameter.
Default = 1.0 (Real)

Yield parameter.
Default = 1.0 (Real)

E1

Coefficient for Young's modulus update.


No default (Real)

E2

Coefficient for Young's modulus update.


No default (Real)

ET

Tangent modulus.

1206 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
No default (Real > 0)

ETAC

Viscosity coefficient in pure compression.


Default = 1.0 (Real > 0)

ETAS

Viscosity coefficient in pure shear.


Default = 1.0 (Real > 0)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX33 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This material can be used only with solid elements, typically used to model low density,
closed cell polyurethane foams such as impact limiters.

4.

The air pressure is computed as


Pair = P0 *
where,

/ (1+

- ), with

= 0 + V/V0 - 1

is the volumetric strain, is the porosity, P0 is the initial air pressure,

initial volumetric strain. The volumetric strain


5.

0 is the

< 0 in compression.

If TID is blank or zero, then


y = A + B(1+ C ), with

= V/V0 - 1 = /0 - 1 = -/(1+)

6.

If TID is defined, y vs.

7.

The Youngs modulus used in the calculation is


E = max(E, E1

Altair Engineering

is read from input of the curve.

+ E2)

OptiStruct 13.0 Reference Guide 1207


Proprietary Information of Altair Engineering

This material assumes NU = 0 no matter what is defined on the corresponding MAT1.


Hence, G = 0.5 * E.
8.

This card is represented as an extension to a MAT1 material in HyperMesh.

1208 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX36
Bulk Data Entry
MATX36 Material Property Extension for Piece-wise Linear Elastic-plastic Material for
Geometric Nonlinear Analysis
Description
Defines additional material properties for piece-wise linear elastic-plastic material for geometric
nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATX36

MID

EPSMAX

EPST1

EPST2

EPSF

FSMOOTH

FC UT

IC H

TPID

PSC A

TID1

FSC A1

EPSR1

...

...

...

TIDi

FSC Ai

EPSRI

(10)

Example

(1)

(2)

(3)

MAT1

102

60.4

MATX36

102

10

1.0

1.0

Altair Engineering

(4)

(5)

(6)

0.33

2.70E-06

(7)

(8)

(9)

(10)

0.0

OptiStruct 13.0 Reference Guide 1209


Proprietary Information of Altair Engineering

Field

Contents

MID

Material identifier of the associated MAT1 (See comment 1).


No default (Integer > 0)

EPSMAX

Failure plastic strain max


Default = 1030 (Real > 0)

EPST1

Maximum tensile failure strain (See comment 5).


Default = 1030

EPST2

(Real > 0)

Maximum tensile failure damage (See comment 6).


Default = 2.0*1030

EPSF

(Real > 0)

Tensile strain for element deletion.


Default = 3.0*1030 (Real > 0)

FSMOOTH

Flag for strain rate smoothing.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering. Only for shell and solid elements.
Default = 1030 (Real > 0)

ICH

Hardening coefficient.
Default = 0.0 (Real > 0)
0.0 - The hardening is a full isotropic model.
1.0 - Hardening uses the kinematic Prager-Ziegler model.
Between 0.0 and 1.0 - Hardening is interpolated between the two models.

TPID

Identification number of a TABLES1 that defines pressure dependent yield


stress function.
No default (Integer > 0)

PSCA

Scale factor for stress in pressure dependent function.

1210 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 1.0 (Real)

TIDi

Identification number of a TABLES1 that defines the yield stress vs. plastic
strain function corresponding to EPSRi. Separate functions must be defined
for different strain rates.
No default (Integer > 0)

FSCAi

Scale factor for TIDi.


Default = 1.0 (Real)

EPSRi

Strain rate. Strain rate values must be given strictly in ascending order.
(Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX36 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The first point of yield stress functions (plastic strain vs. stress) should have a plastic
strain value of zero. If the last point of the first (static) function equals 0 in stress, the
default value of EPSMAX is set to the value of the corresponding plastic strain.

4.

When the plastic strain reaches EPSMAX, the element is deleted.

5.

If the first principal strain 1 reaches t1 = EPST1, the stress is reduced by

with t2 = EPST2.
6.

If the first principal strain 1 reaches t2 = EPST2, the stress is reduced to 0 (but the
element is not deleted).

7.

If the first principal strain 1 reaches f = EPSF, the element is deleted.

8.

Strain rate filtering is used to smooth strain rates. The input FCUT is available only for
shell and solid elements.

9.

Hardening is defined by ICH.


ICH = 0 Fully isotropic hardening
ICH = 1 Prager-Ziegler kinematic hardening

Altair Engineering

OptiStruct 13.0 Reference Guide 1211


Proprietary Information of Altair Engineering

0 < ICH < 1 Interpolation between the two models

10. The kinematic hardening model is not available with global formulation (NIP = 0 on
PSHELX), that is hardening is fully isotropic.
11. In case of kinematic hardening and strain rate dependency, the yield stress depends on
the strain rate.
12. TPID is used to distinguish the behavior in tension and compression for certain materials
(that is pressure dependent yield). This is available for both shell and solid elements.
The effective yield stress is then obtained by multiplying the nominal yield stress by the
yield factor PSCA corresponding to the actual pressure.
13. The first function TID1 is used for strain rate values from 0 to the corresponding strain
rate EPSR1. However, the last function used in the model does not extend to the
maximum strain rate; for higher strain rates, a linear extrapolation will be applied. Hence,
if < EPSRi, the yield stress is interpolated between TIDi and TIDi-1. If < EPSR1, TID1
is used. Above EPSRmax the yield stress is extrapolated.
14. Strain rate values must be given strictly in ascending order. Separate functions must be
defined for different strain rates.
15. At least one strain rate is needed under which the yield stress vs. plastic strain function
is defined.
16. This card is represented as a material in HyperMesh.

1212 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX42
Bulk Data Entry
MATX42 Material Property Extension for Ogden, Mooney-Rivlin Material for Geometric
Nonlinear Analysis
Description
Defines additional material properties for Ogden, Mooney-Rivlin material for geometric nonlinear
analysis. This material is used to model rubber, polymers, and elastomers.
Format
(1)

(2)

(3)

(4)

MATX42

MID

SC UT

LAW

MU1

MU4

(5)

(6)

TBID

FBULK

ALFA1

MU2

ALFA2

ALFA4

MU5

ALFA5

(7)

(8)

(9)

MU3

ALFA3

T3

(10)

Optional continuation lines for prony value:


PRONY

G1

T1

G2

T2

G3

G4

T4

G5

T5

...

Example

(1)

(2)

(3)

MAT1

102

10.0

MATX42

102

LAW

Altair Engineering

0.10

(4)

2.0

(5)

(6)

0.495

6.0E-10

-0.010

-2.0

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 1213


Proprietary Information of Altair Engineering

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

SCUT

Cut-off stress in tension.


Default = 103 0 (Real > 0)

TBID

Identification number of a TABLES1 to define the bulk function f(J) that scales
the bulk modulus vs. relative volume. If TBID = 0, f(J) = const. = 1.0.
Default = 0 (Integer > 0)

FBULK

Scale factor for bulk function.


Default = 1.0 (Real > 0)

LAW

Indicates that material parameters MUi and ALFAi follow.

MUi

Parameter i
(Real)

ALFAi

Parameter i
(Real)

PRONY

Indicates that prony model parameters Gi and Ti follow.

Gi

Parameter G for prony model.


(Real)

Ti

Parameter T for prony model.


(Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX42 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

1214 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

Up to five pairs MUi, ALFAi are permitted.

4.

The recommended Poissons ratio for incompressible material is NU = 0.495. NU is defined


on the corresponding MAT1.

5.

The strain energy density W is computed using the following equation

with i being the ith principal stretch (i = 1 +

is the ith principal engineering

strain). The Cauchy stress is computed as follows:

with J = 1 * 2 * 3 being the relative volume:

The quantity P is the pressure:


P = K * FBULK * f (J) * (J - 1)
The Bulk Modulus K is:

with the ground shear modulus :

6.

An incompressible Mooney-Rivlin material is governed by


W = C1 0 (I1 - 3) + C0 1 (I2 - 3)
where, Ii is ith invariant of the right-hand Cauchy-Green Tensor. It can be modeled using
the following parameters:
1 = 2 * C1 0

Altair Engineering

OptiStruct 13.0 Reference Guide 1215


Proprietary Information of Altair Engineering

2 = -2 * C0 1
1 = 2.0
2 = -2.0
7.

The Kirchhoff viscous stress is given by the convolution integral:

and
8.

This card is represented as a material in HyperMesh.

1216 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX43
Bulk Data Entry
MATX43 Material Property Extension for Hill Orthotropic Material for Geometric Nonlinear
Analysis
Description
Defines additional material properties for Hill Orthotropic material for geometric nonlinear
analysis. This law is only applicable to two-dimensional elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATX43

MID

R00

R45

R90

C HARD

EPSPF

EPST1

EPST2

If strain rate dependent material, at least 1 time, at most 10 times


TID1

FSC A1

EPSR1

TID2

FSC A2

EPSR2

Example

(1)

(2)

(3)

(4)

(5)

(6)

MAT8

102

0.7173

0.7173

0.3

0.4

MATX43

102

1.0

1.0

2.0

1.0

0.1

1.0

0.05

Altair Engineering

(7)

(8)

(9)

(10)

2.7

OptiStruct 13.0 Reference Guide 1217


Proprietary Information of Altair Engineering

Field

Contents

MID

Material ID of the associated MAT8. See comment 1.


No default (Integer > 0)

R00

Lankford parameter at 0 degree.


Default = 1.0 (Real)

R45

Lankford parameter at 45 degrees.


Default = 1.0 (Real)

R90

Lankford parameter at 90 degrees.


Default = 1.0 (Real)

CHARD

Hardening coefficient.
0.0 - The hardening is a full isotropic model.
1.0 - Hardening uses the kinematic Prager-Ziegler model.
Between 0.0 and 1.0 - Hardening is interpolated between the two models.
Default = 0.0 (1.0 > Real > 0.0)

EPSPF

Failure plastic strain.


Default = 1030 (Real)

EPST1

Tensile failure strain.


Default = 1030 (Real)

EPST2

Tensile failure strain.


Default = 2.0*1030 (Real)

TIDi

Identification number of a TABLES1 that defines the yield stress vs. plastic
strain function corresponding to EPSRi. Separate functions must be defined
for different strain rates.
Integer > 0

1218 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FSCAi

Scale factor for ith function.


Default= 1.0 (Real)

EPSRi

Strain rate for ith function.


(Real)

Comments
1.

The material identification number must be that of an existing MAT8 bulk data entry. Only
one MATX43 material extension can be associated with a particular MAT8. E1 must be
equal to E2 on MAT8 that is extended by MATX43.

2.

MATX43 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The yield stress is defined by a user function and the yield stress is compared to
equivalent stress.

4.

Angles for Lankford parameters are defined with respect to orthotropic direction 1.

5.

The Lankford parameters r are determined from a simple tensile test at an angle to the
orthotropic direction 1.

6.

The hardening coefficient is used to describe the hardening model. Its value must be
between 0 and 1:
if set to 0, the hardening is full isotropic.
if set to 1, the hardening uses the kinematic Prager-Ziegler model.

Altair Engineering

OptiStruct 13.0 Reference Guide 1219


Proprietary Information of Altair Engineering

for any value between 0 and 1, the hardening is interpolated between the two models.
7.

If the last point of the first (static) function equals 0 in stress, default value of failure
plastic strain EPSPF is set to the corresponding value of plastic strain, p.

8.

If plastic strain p reaches failure plastic strain pmax , the element is deleted.

9.

If 1 (largest principal strain) > t1(EPST1), stress is reduced according to the following
relation:

10. If 1 (largest principal strain) > t2(EPST2), the stress is reduced to be 0 (but the
element is not deleted). If

(EPSRn), yield is interpolated between n and n-1. If

(EPSR1), function 1 is used. Above

, yield is extrapolated.

11. This card is represented as extension to a MAT8 material in HyperMesh.

1220 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX44
Bulk Data Entry
MATX44 Material Property Extension for Cowper-Symonds Elastic-plastic Material for
Geometric Nonlinear Analysis
Description
Defines additional material properties for Cowper-Symonds elastic-plastic material for
geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MATX44

MID

IC H

SIGMAX

IC C

FSMOOTH

FC UT

EPSMAX

EPST1

EPST2

(10)

Example

(1)

(2)

(3)

MAT1

144

0.11

MATX44

144

(4)

(5)

(6)

0.11

9.92E-07

Field

Contents

MID

Material ID of the associated MAT1.

(7)

(8)

(9)

(10)

No default (Integer > 0)


A

Plasticity yield stress.


(Real > 0)

Plasticity hardening parameter.


(Real > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1221


Proprietary Information of Altair Engineering

Field

Contents

Plasticity hardening exponent.


Default = 1.0 (Real)

ICH

Hardening coefficient.
0.0: The hardening is a full isotropic model.
1.0: Hardening uses the kinematic Prager-Ziegler model.
Between 0.0 and 1.0: Hardening is interpolated between the two models.
Default = 0.0 (Real > 0)

SIGMAX

Maximum plastic stress max0


Default = 1030 (Real > 0)

Strain rate coefficient.


Default = 0.0 (Real)

Strain rate exponent.


Default = 1.0 (Real)

ICC

Flag for strain rate dependency of max (See comment 5).


Default = ON (ON or OFF)

FSMOOTH

Flag for strain rate smoothing.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering.


Default = 1030 (Real > 0)

EPSMAX

Failure plastic strain.


Default = 1030 (Real > 0)

EPST1

Tensile rupture strain 1.

1222 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 1030 (Real > 0)

EPST2

Tensile rupture strain 2.


Default = 2.0 * 1030 (Real > 0)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX44 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The Cowper-Symonds models an elastic-plastic material, only for solids and shells. The
basic principle is the same as the standard Johnson-Cook model; the only difference
between the two lies in the expression for strain rate effect on flow stress

with p being plastic strain, and


4.

being the strain rate.

Hardening is defined by ICH.


ICH = 0 Fully isotropic hardening.
ICH = 1 Prager-Ziegler kinematic hardening.
0 < ICH < 1 Interpolation between the two models.

5.

ICC controls the strain rate effect.

Altair Engineering

OptiStruct 13.0 Reference Guide 1223


Proprietary Information of Altair Engineering

6.

No strain rate effects are considered in rod elements.

7.

Strain rate filtering is used to smooth strain rates. The input FCUT is available only for
shell and solid elements.

8.

When the plastic strain reaches EPSMAX, the element is deleted.

9.

If the first principal strain 1 reaches t1 = EPST1, the stress is reduced by

with t2 = EPST2.
10. If the first principal strain 1 reaches t2 = EPST2, the stress is reduced to 0 (but the
element is not deleted).
11. If the first principal strain 1 reaches f = EPSF, the element is deleted.
12. This card is represented as an extension to a MAT1 material in HyperMesh.

1224 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX60
Bulk Data Entry
MATX60 Material Property Extension for Piece-wise Nonlinear Elastic-plastic Material for
Geometric Nonlinear Analysis
Description
Defines additional material properties for piece-wise nonlinear elastic-plastic material for
geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MATX60

MID

EPSPF

EPST1

EPST2

TPID

PSC A

(7)

FSMOOTH C HARD

(8)

(9)

(10)

FC UT

EPSF

Strain rate dependent material, at least 4 times, at most 10 times:


TID1

FSC A1

EPSR1

TID2

FSC A2

EPSR2

...

...

...

Example

(1)

(2)

(3)

MAT1

102

900

MATX60

102

(4)

101

1.0

4.2E-7

102

1.0

4.2e6

Altair Engineering

(5)

(6)

0.33

1E1

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 1225


Proprietary Information of Altair Engineering

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

EPSPF

Failure plastic strain.


Default = 1030 (Real > 0)

EPST1

Maximum tensile failure strain (See comment 5).


Default = 1030 (Real > 0)

EPST2

Maximum tensile failure damage (See comment 6).


Default = 2.0*1030 (Real > 0)

FSMOOTH

Flag for strain rate smoothing.


Default = OFF (ON or OFF)

CHARD

Hardening coefficient.
0.0: The hardening is a full isotropic model.
1.0: Hardening uses the kinematic Prager-Ziegler model.
Between 0.0 and 1.0: Hardening is interpolated between the two models.
Default = 0.0 (1.0 > Real > 0)

FCUT

Cutoff frequency for strain rate filtering. Only for shell and solid elements.
Default = 1030 (Real > 0)

EPSF

Tensile strain for element deletion.


Default = 3.0*1030 (Real > 0)

TPID

Identification number of a TABLES1 that defines pressure dependent yield


stress function.
No default (Integer > 0)

PSCA

Scale factor for stress in pressure dependent function.

1226 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 1.0 (Real)

TIDi

Identification number of a TABLES1 that defines the yield stress vs. plastic
strain rate function corresponding to EPSRi. Separate functions must be
defined for different strain rates.
No default (Integer > 0)

FSCAi

Scale factor for TIDi.


Default = 1.0 (Real)

EPSRi

Strain rate. Strain rate values must be given strictly in ascending order.
(Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATX60 material extension can be associated with a particular MAT1.

2.

MATX60 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The first point of yield stress functions (plastic strain vs. stress) should have a plastic
strain value of zero. If the last point of the first (static) function equals 0 in stress, the
default value of EPSMAX is set to the value of the corresponding plastic strain.

4.

When the plastic strain reaches EPSMAX, the element is deleted.

5.

If the first principal strain 1 reaches t1 (EPST1), the stress is reduced by

with t2 = EPST2.
6.

If the first principal strain 1 reaches t2 (EPST2), the stress is reduced to 0 (but the
element is not deleted).

7.

If the first principal strain 1 reaches f (EPSF), the element is deleted.

8.

Strain rate filtering is used to smooth strain rates. The input FCUT is available only for
shell and solid elements.

9.

Hardening is defined by ICH.

Altair Engineering

OptiStruct 13.0 Reference Guide 1227


Proprietary Information of Altair Engineering

ICH = 0 Fully isotropic hardening


ICH = 1 Prager-Ziegler kinematic hardening
0 < ICH < 1 Interpolation between the two models

Isotropic Hardening

Prager-Ziegler Kinematic Hardening

10. The kinematic hardening model is not available with global formulation (NIP = 0 on
PSHELX), that is hardening is fully isotropic.
11. In case of kinematic hardening and strain rate dependency, the yield stress depends on
the strain rate.
12. TPID is used to distinguish the behavior in tension and compression for certain materials
(that is pressure dependent yield). This is available for solid elements only. The effective
yield stress is then obtained by multiplying the nominal yield stress by the yield factor
PSCA corresponding to the actual pressure.
13. If

=EPSRn) , yield stress is a cubic interpolation between functions f n-

1, f n, f n+1 and f n+2.

If

, yield stress is interpolated between functions f 1, f 2, and f 3.

If
, where Nfunc is the function number for strain rate, yield is
extrapolated between functions f Nfunc-3, f Nfunc-2, f Nfunc-1 and f Nfunc.
If

, yield is extrapolated between functions f Nfunc-2, f Nfunc-1, and f Nfunc.

14. Strain rate values must be given strictly in ascending order. Separate functions must be
defined for different strain rates.
15. This card is represented as an extension to a MAT1 material in HyperMesh.

1228 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX62
Bulk Data Entry
MATX62 Material Property Extension for Hyper-visco-elastic Material for Geometric Nonlinear
Analysis
Description
Defines additional material properties for Hyper-visco-elastic material for geometric nonlinear
analysis. This material is used to model rubber, polymers, and elastomers.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATX62

MID

MUMAX

LAW

(9)

MU1

ALFA1

MU2

ALFA2

MU3

ALFA3

MU4

ALFA4

MU5

ALFA5

...

(10)

Optional continuation lines for Maxwell value:


MAXWELL

GAM1

T1

GAM2

T2

GAM3

GAM4

T4

GAM5

T5

...

T3

Example

(1)

(2)

(3)

MAT1

102

10.0

MATX62

102

LAW

Altair Engineering

0.10

(4)

2.0

(5)

(6)

0.495

6.0E-10

-0.010

-2.0

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 1229


Proprietary Information of Altair Engineering

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

MUMAX

Maximum viscosity.
Default = 1030 (Real)

LAW

Indicates that material parameters MUi and ALFAi follow.

MUi

Parameter i
(Real)

ALFAi

Parameter i
(Real)

MAXWELL

Indicates that MAXWELL model parameter pairs GAMi and Ti follow.

GAMi

Stiffness ratio i.
(Real)

Ti

Time relaxation i.
(Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX62 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This material is compatible with solid and shell elements.

4.

NU is defined on the corresponding MAT1.

5.

If no pair GAM1, T1 is given the law is hyper-elastic.

1230 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

The strain energy density W is computed using the following equation:

with i being the ith principal stretch, J = 1 * 2 * 3 being the relative volume and

. O < NU < 0.5


The ground shear modulus is:

7.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1231


Proprietary Information of Altair Engineering

MATX65
Bulk Data Entry
MATX65 Material Property Extension for Tabulated Strain Rate Dependent Elastic-Plastic
Material for Geometric Nonlinear Analysis
Description
Defines additional material properties for tabulated strain rate dependent elastic-plastic
material for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MATX65

MID

EPSMAX

FSMOOTH

FC UT

NLOAD

(8)

(9)

(10)

If NLOAD > 1, NLOAD times


TIDL

TIDU

EPSR

FSC AL

Example

(1)

(2)

(3)

MAT1

91

60.4

MATX65

91

2.70E-06

(4)

(5)

(6)

0.33

2.70E-06

(7)

(8)

(9)

(10)

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

1232 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EPSMAX

Failure plastic strain max


(Real > 0)

FSMOOTH

Strain rate filtering flag.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering.


Default = 1.E30 (Real > 0)

NLOAD

Number of loading/unloading stress-strain function pairs.


Default = 0 (Integer > 0)

TIDL

Identification number of TABLES1 entry that defines the loading stress-strain


function.
(Integer > 0)

TIDU

Identification number of TABLES1 entry that defines the unloading stressstrain function.
(Integer > 0)

EPSR

Strain rate.
Default = 1.0 (Real)

FSCAL

Scale factor for stress.


Default = 1.0 (Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX65 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The material law is defined by pairs of stress functions for loading and unloading at a
constant strain rate. For each strain rate, the yield stress is defined by the intersection
between loading and unloading curves. Unloading follows unloading curve shifted by
plastic strain value. Strain rates are interpolated using input values. In the elastic range,
stress smaller than the yield value, the material behavior is elastic with hysteresis. It is

Altair Engineering

OptiStruct 13.0 Reference Guide 1233


Proprietary Information of Altair Engineering

limited by loading and unloading curves.

Loading and unloading function sets for constant strain rates.

The Young's modulus must be greater than the maximum function slopes, and is used to
follow loading and unloading paths between limiting curves.

For a constant strain rate, user defined functions set the limits for the cycling loading.

1234 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1235


Proprietary Information of Altair Engineering

MATX68
Bulk Data Entry
MATX68 Material Property Extension for Honeycomb Material for Geometric Nonlinear
Analysis
Description
Defines additional material properties for Honeycomb material for geometric nonlinear analysis.
This law is only applicable to solid elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MATX68

MID

TIID11

TIID22

TIID33

IFLAG1

FSC AI11

FSC AI22

FSC AI33

EPSFI11

EPSFI22

EPSFI33

TIID12

TIID23

TIID31

IFLAG2

FSC AI12

FSC AI23

FSC AI31

EPSFI12

EPSFI23

EPSFI31

TIID21

TIID32

TIID13

FSC AI21

FSC AI32

FSC AI13

TRID11

TRID22

TRID33

FSC AR11

FSC AR22

FSC AR33

EPST11

EPST22

EPST33

TRID12

TRID23

TRID31

FSC AR12

FSC AR23

FSC AR31

EPST12

EPST23

EPST31

TRID21

TRID32

TRID13

FSC AR21

FSC AR32

FSC AR13

(9)

(10)

Example

1236 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MAT9ORT

102

0.2

0.02

0.02

0.33

0.33

0.33

0.286E-7

0.1

0.01

0.1

11

22

33

NEGSTR

1.0

1.0

1.0

12

23

31

NEGSTR

1.0

1.0

1.0

0.0

0.0

0.0

21

32

13

1.0

1.0

1.0

11

22

33

1.0

1.0

1.0

0.8

0.0

0.0

12

23

31

1.0

1.0

1.0

0.0

0.0

0.0

21

32

13

1.0

1.0

1.0

MATX68

(10)

102

Field

Contents

MID

Material ID of the associated MAT9ORT. See comment 1.


No default (Integer > 0)

TIID11

Identification number of a TABLES1 that defines initial yield stress function in


direction 11.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1237


Proprietary Information of Altair Engineering

Field

Contents

TIID22

Identification number of a TABLES1 that defines initial yield stress function in


direction 22.
No default (Integer > 0)

TIID33

Identification number of a TABLES1 that defines initial yield stress function in


direction 33.
No default (Integer > 0)

IFLAG1

Strain formulation for yield functions 11, 22, and 33. See comment 4.
VOLSTR - Yield stress is a function of volumetric strains.
STR - Yield stress is a function of strains.
NEGSTR - Yield stress is a function of negative strains.
Default = VOLSTR (VOLSTR, STR, NEGSTR)

FSCAI11

Scale factor on initial yield stress function in direction 11.


Default = 1.0 (Real)

FSCAI22

Scale factor on initial yield stress function in direction 22.


Default = 1.0 (Real)

FSCAI33

Scale factor on initial yield stress function in direction 33.


Default = 1.0 (Real)

EPSFI11

Initial failure strain under tension or compression in direction 11.


(Real)

EPSFI22

Initial failure strain under tension or compression in direction 22.


(Real)

EPSFI33

Initial failure strain under tension or compression in direction 33.


(Real)

TIID12

Identification number of a TABLES1 that defines initial shear yield stress

1238 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
function in direction 12.
No default (Integer > 0)

TIID23

Identification number of a TABLES1 that defines Initial shear yield stress


function in direction 23.
No default (Integer > 0)

TIID31

Identification number of a TABLES1 that defines Initial shear yield stress


function in direction 31.
No default (Integer > 0)

IFLAG2

Strain formulation for yield functions 12, 23, and 31.


VOLSTR - Yield stress is a function of volumetric strains.
STR - Yield stress is a function of strains.
NEGSTR - Yield stress is a function of negative strains.
Default = VOLSTR (VOLSTR, STR, NEGSTR)

FSCAI12

Scale factor on initial shear yield stress function in direction 12.


Default = 1.0 (Real)

FSCAI23

Scale factor on initial shear yield stress function in direction 23.


Default = 1.0 (Real)

FSCAI31

Scale factor on initial shear yield stress function in direction 31.


Default = 1.0 (Real)

EPSFI12

Initial failure strain under tension or compression in direction 12.


(Real)

EPSFI23

Initial failure strain under tension or compression in direction 23.


(Real)

EPSFI31

Initial failure strain under tension or compression in direction 31.

Altair Engineering

OptiStruct 13.0 Reference Guide 1239


Proprietary Information of Altair Engineering

Field

Contents
(Real)

TIID21

Identification number of a TABLES1 that defines Initial shear yield stress


function in direction 21.
No default (Integer > 0)

TIID32

Identification number of a TABLES1 that defines Initial shear yield stress


function in direction 32.
No default (Integer > 0)

TIID13

Identification number of a TABLES1 that defines Initial shear yield stress


function in direction 13.
No default (Integer > 0)

FSCAI21

Scale factor on initial shear yield stress function in direction 21.


Default = 1.0 (Real)

FSCAI32

Scale factor on initial shear yield stress function in direction 32.


Default = 1.0 (Real)

FSCAI13

Scale factor on initial shear yield stress function in direction 13.


Default = 1.0 (Real)

TRID11

Identification number of a TABLES1 that defines residual yield stress function


in direction 11.
No default (Integer > 0)

TRID22

Identification number of a TABLES1 that defines residual yield stress function


in direction 22.
No default (Integer > 0)

TRID33

Identification number of a TABLES1 that defines residual yield stress function


in direction 33.
No default (Integer > 0)

1240 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FSCAR11

Scale factor on residual yield stress function in direction 11.


Default = 1.0 (Real)

FSCAR22

Scale factor on residual yield stress function in direction 22.


Default = 1.0 (Real)

FSCAR33

Scale factor on residual yield stress function in direction 33.


Default = 1.0 (Real)

EPST11

Transition strain in direction 11.


(Real)

EPST22

Transition strain in direction 22.


(Real)

EPST33

Transition strain in direction 33.


(Real)

TRID12

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 12.
No default (Integer > 0)

TRID23

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 23.
No default (Integer > 0)

TRID31

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 31.
No default (Integer > 0)

FSCAR12

Scale factor on residual shear yield stress function in direction 12.


Default = 1.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1241


Proprietary Information of Altair Engineering

Field

Contents

FSCAR23

Scale factor on residual shear yield stress function in direction 23.


Default = 1.0 (Real)

FSCAR31

Scale factor on residual shear yield stress function in direction 31.


Default = 1.0 (Real)

EPST12

Transition strain in direction 12.


(Real)

EPST23

Transition strain in direction 23.


(Real)

EPST31

Transition strain in direction 31.


(Real)

TRID21

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 21.
No default (Integer > 0)

TRID32

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 32.
No default (Integer > 0)

TRID13

Identification number of a TABLES1 that defines residual shear yield stress


function in direction 13.
No default (Integer > 0)

FSCAR21

Scale factor on residual shear yield stress function in direction 21.


Default = 1.0 (Real)

FSCAR32

Scale factor on residual shear yield stress function in direction 32.


Default = 1.0 (Real)

1242 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FSCAR13

Scale factor on residual shear yield stress function in direction 13.


Default = 1.0 (Real)

Comments
1.

The material identification number must be that of an existing MAT9ORT bulk data entry.
Only one MATX68 material extension can be associated with a particular MAT9ORT.

2.

MATX68 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

This law is compatible with 8 node brick elements with ISOLID =1 or ISOLID =2 on
PSOLIDX only.

4.

When switching from a volumetric strain formulation to a strain formulation, IFLAGi =


NEGSTR allows the same function definition to be retained.

5.

If one of the failure or shear failure strains is reached, the element is deleted.

6.

Transition strains define transition from initial yield stress function to residual yield stress
function.

7.

If one of the transition or shear transition strains is reached, the element has yield stress
described by residual functions in each direction, Transition is applied to the neighbor
elements.

8.

This card is represented as extension to a MAT9ORT material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1243


Proprietary Information of Altair Engineering

MATX70
Bulk Data Entry
MATX70 Material Property Extension for Tabulated Visco-elastic Foam Material for
Geometric Nonlinear Analysis
Description
Defines additional material properties for tabulated visco-elastic foam material for geometric
nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATX70

MID

EMAX

EPSMAX

FSMOOTH

FC UT

NLOAD

NULOAD

IFLAG

SHAPE

HYS

If NLOAD > 1, NLOAD times


TIDL

EPSRL

FSC ALL

If NULOAD > 0, NULOAD times


TIDU

EPSRU

FSC ALU

Example

(1)

(2)

(3)

MAT1

170

0.1

MATX70

170

1.0

(4)

0.8

(5)

(6)

0.1

9.9E-07

(7)

(8)

(9)

(10)

1244 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

EMAX

Maximum young modulus .


(Real > 0)

EPSMAX

Maximum plastic (failure) strain.


(Real > 0)

FSMOOTH

Strain rate smoothing flag.


Default = OFF (ON or OFF)

FCUT

Cutoff frequency for strain rate filtering.


Default = 1.E30 (Real > 0)

NLOAD

Number of loading stress-strain function.


Default = 1 (Integer > 1)

NULOAD

Number of unloading stress-strain function. If FLAG in this card is 1, 2, 3, or


4, NULOAD must be zero.
Default = 1, if FLAG = 0
Default = 0, if FLAG = 1, 2, 3, or 4
(Integer > 0)

IFLAG

Flag to control the loading/unloading behavior (See comment 5).


Default = 0 (Integer)
0 Behavior follows the loading and unloading curves respectively.
1 Behavior follows the loading/unloading curves. For unloading, the
deviatoric stress is modified.
2 Behavior follows the loading/unloading curves. For unloading, the stress
tensor is modified.

Altair Engineering

OptiStruct 13.0 Reference Guide 1245


Proprietary Information of Altair Engineering

Field

Contents
3 The loading curve is used for both loading and unloading. For unloading,
the deviatoric stress is modified. The unloading curves are ignored.
4 - The loading curve is used for both loading and unloading. For unloading,
the stress tensor is modified. The unloading curves are ignored.

SHAPE

Shape factor.
Default = 1.0 (Real)

HYS

Hysteresis unloading factor.


Default = 1.0 (Real)

TIDL

Identification number of TABLES1 entry that defines the loading function.


(Integer > 0)

EPSRL

Strain rate for loading function.


Default = 0.0 (Real)

FSCALL

Scale factor for loading function.


Default = 1.0 (Real)

TIDU

Identification number of TABLES1 entry that defines the unloading function.


No default (Integer > 0)

EPSRU

Strain rate for unloading function.


Default = 0.0 (Real)

FSCALU

Scale factor for unloading function.


Default = 1.0 (Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX70 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

1246 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

This material law can be used only with solid elements. The corresponding PSOLIDX
property must define ISOLID = 1 (Belytschko element), ISMSTR = 1 (small strain), and
IFRAME = OFF (not co-rotational).

4.

The loading and unloading functions use engineering stress-strain curve.

Loading and unloading stress-strain curves

5.

The loading and unloading behavior is determined by IFLAG.


IFLAG = 0 - The material behavior follows the defined curves for loading and unloading.
NLOAD and NULOAD must be greater than 0.
IFLAG = 1 - Both loading curves are used respectively. For unloading, the deviatoric
stress is modified by using the quasi-static unloading curve
= (1 - D)( + p*I) p*I
where, D is calculated from the quasi-static unloading curve,

are the current stresses computed respectively from the unloading and quasi-static
curves.
The pressure is:
p = -(xx + yy + zz) / 3
IFLAG = 2 - Both loading and unloading curves are used respectively. For unloading,
the stress tensor is modified using the quasi-static unloading curve = (1 - D), where
D is calculated from the quasi-static unloading curve,

are the current stresses computed respectively from the unloading and quasi-static
curves.

Altair Engineering

OptiStruct 13.0 Reference Guide 1247


Proprietary Information of Altair Engineering

IFLAG = 3 - The loading curves are used for both loading and unloading behavior. The
unloading curve is ignored. The deviatoric unloading stress is modified using
= (1 - D)( + p*I) p*I

where, Wcur and Wmax are the current and maximum energy, respectively.
IFLAG = 4 - The loading curves are used for both loading and unloading behavior. The
unloading curve is ignored. The unloading stress tensor is modified using = (1 - D).

where, Wcur and Wmax are the current and maximum energy, respectively.
For IFLAG = 3, 4 the unloading curves are not used.
6.

For stresses above the last load function, the behavior is extrapolated by using the two
last load functions. In order to avoid huge stress values, it is recommended to repeat the
last load function.

7.

When maximum plastic strain EPSMAX is reached, EMAX is used whatever the curve
definition is.

8.

If EMAX is blank, EMAX is set and equal to Young modulus on MAT1 card.

9.

If EPSMAX is blank, it will be calculated automatically if EMAX is less than the maximum
tangent according to the input stress-strain curves.

10. Young's modulus E on MAT1 card would be modified automatically if it is less than the
initial value according to the input stress-strain curves' tangents.
11. This card is represented as a material in HyperMesh.

1248 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MATX82
Bulk Data Entry
MATX82 Material Property Extension for Ogden Material for Geometric Nonlinear Analysis
Description
Defines additional material properties for Ogden material for geometric nonlinear analysis. This
material is used to model rubber, polymers, and elastomers.
Format
(1)

(2)

MATX82

MID

LAW

(3)

(4)

(5)

(6)

(7)

(8)

MU1

ALFA1

D1

MU2

ALFA2

D2

MU3

ALFA3

D3

MU4

ALFA4

D4

(9)

(10)

...

Example

(1)

(2)

(3)

MAT1

102

10.0

MATX82

102

LAW

0.10

(4)

2.0

(5)

(6)

0.495

6.0E-10

-0.010

(7)

(8)

(9)

(10)

-2.0

Field

Contents

MID

Material ID of the associated MAT1 (See comment 1).


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1249


Proprietary Information of Altair Engineering

Field

Contents

LAW

Indicates that material parameters MUi, ALFAi, and Di follow.

MUi

Parameter i
(Real)

ALFAi

Parameter i
(Real)

Di

Parameter Di
(Real)

Comments
1.

The material identification number must be that of an existing MAT1 bulk data entry. Only
one MATXi material extension can be associated with a particular MAT1.

2.

MATX82 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

NU is defined on the corresponding MAT1. For material without Poisson effect, a small NU
(for example, =1.E-10) should be defined.

4.

The strain energy density W is computed using the following equation

with i being the ith principal stretch, J = 1 * 2 * 3 being the relative volume and

.
5.

The Bulk Modulus K is:


If NU = 0, then

1250 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

is modified to respect

If NU = 0 and D1 = 0, then u = 0.475.


6.

The ground shear modulus is

7.

This card is represented as a material in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1251


Proprietary Information of Altair Engineering

MBACT
Bulk Data Entry
MBACT Activate an Entity/set in the Multi-body System
Description
Defines the entity/set that needs to be activated in the multi-body system for the
subsequent simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBAC T

ID

ETYPE

ID1

ID2

ID3

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBAC T

ID

ETYPE

IDST

THRU

IDEND

(8)

(9)

(10)

(8)

(9)

(10)

or

Example

(1)

(2)

(3)

(4)

MBAC T

ID

MOTION

92

(5)

Field

Contents

ID

Unique identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
ETYPE

Entity type that needs to be activated.


(Option "CMBEAM", "CMBUSH", "CMSPDP", "JOINT", "MLOAD", or "MOTION")

1252 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

ID1, ID2,

Entity/Set IDs that need to be activated.


(Integer > 0)

IDST

Entity/Set ID range start.


(Integer > 0)

THRU

Keyword to indicate entity/set ID range is specified.

IDEND

Entity/Set ID range end.


(Integer > IDST)

Comments
1.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1253


Proprietary Information of Altair Engineering

MBCNTDS
Bulk Data Entry
MBCNTDS Multi-body Contact with Deformable Surface
Description
Defines a Multi-body Contact between a set of nodes and a deformable surface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBC NTDS

C ID

SID

SRFID

C NFTYPE

STIFF

DAMP

RADIUS

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBC NTD
S

21

LINEAR

1E6

10

.1

Field

Contents

CID

Contact identification number.


No default (Integer > 0)

SID1

Set identification number of a set of nodes.


No default (Integer > 0)

SRFID

Multi-body deformable surface (MBDSRF) identification number.


No default (Integer > 0)

CNFTYPE

Contact Normal Force Type. Select from LINEAR and POISSON.


No default (CHARACTER: LINEAR, POISSON)

STIFF

For CNFTYPE=LINEAR, this parameter specifies the interface stiffness


coefficient.
For CNFTYPE=POISSON, this parameter specifies the penalty parameter

1254 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
which is related to the stiffness RJTODO.
Default = 0.0 (Real > 0.0)

DAMP

For CNFTYPE=LINEAR, this parameter specifies the interface damping.


Default = 0.0 (Real > 0)
For CNFTYPE=POISSON, this parameter specifies the coefficient of restitution
value for the contact.
Default = 1.0 (0.0 < Real < 1.0)

RADIUS

Radius of the sphere geometry centered at the origin of the I marker.


Default = 0.0 (Real > 0)

Comments
1.

This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1255


Proprietary Information of Altair Engineering

MBCNTR
Bulk Data Entry
MBCNTR Multi-body Contact of Type Rigid to Rigid
Description
Defines a Multi-body Contact between rigid bodies.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBC NTR

C ID

SID1

SID2

C NFTYPE

PENAL

C OR

MUSTAT

MUDYN

C FFTYPE

STVEL

FTVEL

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBC NTR

POISSON

1E6

.5

.7

.3

C OUL

.1

.8

Field

Contents

CID

Contact identification number.

(10)

No default (Integer > 0)


SID1

Set identification number for a set of elements.


No default (Integer > 0)

SID2

Set identification number for a set of elements.

CNFTYPE

Contact normal force type.


Default = POISSON

PENAL

Penalty factor.

1256 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 1.0 (Real > 0.0)

COR

Coefficient of restitution.
Default = 1.0 (0.0 < Real < 1.0)

MUSTAT

Coefficient of static friction.


Default = 0.0 (Real > 0.0)

MUDYN

Coefficient of dynamic friction.


Default = 0.0 (Real > 0.0)

CFFTYPE

Contact friction force type


Default = (COUL, NONE, DYNA)

STVEL

Stiction transition velocity. Defines the slip velocity at which the static
coefficient of friction MUSTAT is applied.
Default = 0.0 (Real > 0.0)

FTVEL

Friction transition velocity. Defines the slip velocity at which the


dynamic coefficient of friction MUDYN is applied.
Default = 0.0 (Real > 0.0)

Comments
1.

This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1257


Proprietary Information of Altair Engineering

MBCRV
Bulk Data Entry
MBCRV XY Curve Definition
Description
Specifies the data used to define a curve.
Format
(1)

(2)

(3)

MBC RV

C VID

LINEAR

X1

Y1

(4)

(5)

(6)

(7)

(8)

(9)

X2

Y2

Xn

Yn

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBC RV

399

1.0

1.1

2.0

0.0

3.0

14.2

4.0

19.9

5.0

12.1

Field

Contents

CVID

Curve identification number.

(10)

No default (Integer > 0)


LINEAR

If the LINEAR keyword is specified, linear extrapolation is used to


determine the curve data when the independent coordinate goes out of
the range specified on the Xi fields.
If this field is blank, no extrapolation is applied and an ERROR is output
when the independent coordinate goes out of range.

1258 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = blank

X1, X2, X3, ,


Xn

Independent curve data.


No default (Real, X1 < X2 < X3 < )

Y1, Y2, Y3, ,


Yn

Dependent curve data.


No default (Real)

Comments
1.

This card is represented as a curve in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1259


Proprietary Information of Altair Engineering

MBCVCV
Bulk Data Entry
MBCVCV Multi-body Curve to Curve Constraint
Description
Defines a Curve to Curve Constraint.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MBC VC V

JID

blank

PC ID1

G3

V1

blank

blank

PC ID2

G4

V2

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

MBC VC V

Field

Contents

JID

Joint identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


PCID1

Parametric curve (MBPCRV) identification number.


No default (Integer > 0)

PCID2

Parametric curve (MBPCRV) identification number.


No default (Integer > 0)

G3

This grid specifies the guess for the initial contact point on the first
curve.

1260 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Although this parameter is optional, specifying it helps the solver in
determining the initial contact point.

V1

Specifies the sliding velocity of the contact point relative to the part on
which the curve is etched. V1 is positive when contact point is moving
toward the start of the curve and vice-versa.
Default = 0.0 (Real)

G4

This grid specifies the guess for the initial contact point on the second
curve.
Although this parameter is optional, specifying it helps the solver in
determining the initial contact point.

V2

Specifies the sliding velocity of the contact point relative to the part on
which the curve is etched. V2 is positive when contact point is moving
toward the start of the curve and vice-versa.
Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1261


Proprietary Information of Altair Engineering

MBDCRV
Bulk Data Entry
MBDCRV Multi-body Deformable Curve
Description
Defines an ordered list of grids as a Multi-body Deformable Curve.
Format
(1)

(2)

MBDC RV

(3)

DC ID

G1

(4)

ENDTYPE
LAMBDAL
L

G2

(5)

(6)

(7)

ENDTYPE
R

LAMBDA
R

NSEG

G3

(8)

(9)

(10)

Example

(1)
MBDC RV

(2)

(3)

NATURA
L

201

202

(4)

(5)

(6)

(7)

(8)

C ANTILEVE
R

0.5

100

204

205

203

Field

Contents

DCID

Curve identification number.

(9)

(10)

No default (Integer > 0)


ENDTYPEL

Select from NATURAL, PARABOLIC, PERIODIC and CANTILEVER. See comment


1.
Default = NATURAL

LAMBDAL

This parameter is only applicable for CANTILEVER type end condition. It should
be left blank for other end conditions.
A real valued parameter in the interval [0,1] that controls the left end
condition for CUBIC spline interpolation. A value of 0 implies NATURAL end
condition while a value of 1 implies PARABOLIC end condition.

1262 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 0.0 (0.0 < Real < 1.0)

ENDTYPER

Select from: NATURAL, PARABOLIC, PERIODIC and CANTILEVER. See comment


1.
Default = NATURAL

LAMBDAR

This parameter is only applicable for CANTILEVER type end condition. It should
be left blank for other end conditions.
A real valued parameter in the interval [0,1] that controls the left end
condition for CUBIC spline interpolation. A value of 0 implies NATURAL end
condition while a value of 1 implies PARABOLIC end condition.
Default = 0.0 (0.0 < Real < 1.0)

NSEG

Number of segments used to visualize the deformable curve in animation.


No default (Integer > 0)

G1, G2, G3,

Ordered list of grid IDs defining the curve.

Comments
1.

The deformable curve is generated using the CUBIC spline interpolation which requires
assumptions on the second derivative of the interpolating function at either end of the
curve. The keywords NATURAL, PARABOLIC, PERIODIC and CANTILEVER represent the
four standard assumptions defined as follows:

Note that =0.0 implies NATURAL (or free) end conditions and =1.0 implies PARABOLIC
end conditions.
2.

This card is represented as a set in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1263


Proprietary Information of Altair Engineering

MBDEACT
Bulk Data Entry
MBDEACT Deactivate an Entity/set in the Multi-body System
Description
Defines the entity/set that needs to be deactivated in the multi-body system for the
subsequent simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBDEAC T

ID

ETYPE

ID1

ID2

ID3

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBDEAC T

ID

ETYPE

IDST

THRU

IDEND

(8)

(9)

(10)

(8)

(9)

(10)

or

Example

(1)

(2)

(3)

(4)

(5)

(6)

MBDEAC T

ID

MOTION

92

94

199

Field

Contents

ID

Unique identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
ETYPE

Entity type that needs to be deactivated.


(Option "CMBEAM", "CMBUSH", "CMSPDP2", "JOINT", "MLOAD", or
"MOTION")

1264 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

ID1, ID2,

Entity/Set ID that needs to be deactivated.


(Integer > 0)

IDST

Entity/Set ID range start.


(Integer > 0)

THRU

Keyword to indicate entity/set ID range is specified.

IDEND

Entity/Set ID range end.


(Integer > IDST)

Comments
1.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1265


Proprietary Information of Altair Engineering

MBDSRF
Bulk Data Entry
MBDSRF Multi-body Deformable Surface
Description
Defines a multi-body deformable surface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBDSRF

SRFID

NROW

NC OL

ENDTYPE

NSEGU

NSEGV

G1

G2

G3

G4

G5

G6

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBDSRF

NATURAL

100

100

201

202

203

204

205

209

210

211

212

213

217

218

Field

Contents

SRFID

Surface identification number.

(8)

(9)

206

207

206

214

215

216

(10)

No default (Integer > 0)


NROW

Number of rows of nodes.

NCOL

Number of columns of nodes.

ENDTYPE

Select from: NATURAL, PARABOLIC and PERIODIC. See comment 1.

1266 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = NATURAL

NSEGU, NSEGV Number of segments along the U and V coordinates used to discretize the
deformable surface for animation purposes.
No default (Integer > 0)
G1, G2,

Row-wise list of nodes. The first NROW IDs form the first row; the second
NROW IDs form the second row, and so on. The list must contain a total of
NROW*NCOL grid IDs.

Comments
1.

The deformable surface is generated using the CUBIC spline interpolation which requires
assumptions on the second derivative of the interpolating function at the end of the
surface. The keywords NATURAL, PARABOLIC and PERIODIC represent assumptions defined
as follows:

2.

The MBDSRF element is not supported by the Force Imbalance method of static
equilibrium.

3.

The MBDSRF element does not possess any inherent inertia, stiffness or damping.

4.

This card is represented as a set in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1267


Proprietary Information of Altair Engineering

MBFRC
Bulk Data Entry
MBFRC Force for Multi-body Solution Sequence
Description
Defines a constant force at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBFRC

SID

G1

C ID

G3/N1

N2

N3

G2

(10)

G4

Example

(1)

(2)

(3)

MBFRC

345

(4)

(5)

(6)

(7)

(8)

100.0

0.0

1.0

0.0

(9)

(10)

201

Field

Contents

SID

Load set identification number.


No default (Integer > 0)

G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0 or blank)

1268 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Force magnitude.
No default (Real)

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1, N2, N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank, then the force is an action-only force.
Default = blank (Integer > 0 or blank)

G4

Grid point identification number whose parent body hosts the coordinate
system with respect to which the force is defined. The force vector
changes direction with the orientation of the body. See comment 1.
Default = blank (Integer > 0 or blank)

Comments
1.

If G4 is not specified, the force is defined with respect to the ground body (that is the
basic coordinate systems).

2.

This card is represented as a force load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1269


Proprietary Information of Altair Engineering

MBFRCC
Bulk Data Entry
MBFRCC Curve Force for Multi-body Solution Sequence
Description
Defines a curve force at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBFRC C

SID

G1

C ID

C VID

G3/N1

N2

N3

G2

INT

EID

G4

(10)

Example

(1)

(2)

(3)

MBFRC C

345

AKIMA

41

(4)

(5)

(6)

(7)

(8)

0.0

1.0

0.0

(9)

(10)

201

Field

Contents

SID

Load set identification number.


No default (Integer > 0)

G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0, or blank)

1270 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

CVID

Set identification number of the MBCRV entry that gives the load vs.
independent variable measured in the coordinate system defined by
CID.
(Integer > 0)

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1, N2, N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank or zero, then the force is an action-only force.
Default = 0 (Integer > 0)

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

G4

Grid point identification number whose parent body hosts the coordinate
system with respect to which the force is defined. The force vector
changes direction with the orientation of the body. See comment 1.
Default = blank (Integer > 0 or blank)

Comments
1.

If G4 is undefined, the force is defined with respect to the ground body (that is the basic
coordinate systems).

2.

This card is represented as a force load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1271


Proprietary Information of Altair Engineering

MBFRCE
Bulk Data Entry
MBFRCE Expression Force for Multi-body Solution Sequence
Description
Defines an expression force at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBFRC E

SID

G1

C ID

EID

G3/N1

N2

N3

G2

(10)

G4

Example

(1)

(2)

(3)

MBFRC E

345

(4)

(5)

(6)

(7)

(8)

49

0.0

1.0

0.0

(9)

(10)

201

Field

Contents

SID

Load set identification number.


No default (Integer > 0)

G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0, or blank)

1272 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EID

Expression identification number of the MBVAR entry that gives the load
measured in the coordinate system defined by CID.
No default (Integer > 0)

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1, N2, N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank or zero, then the force is an action-only force.
Default = 0 (Integer > 0)

G4

Grid point identification number whose parent body hosts the coordinate
system with respect to which the force is defined. The force vector
changes direction with the orientation of the body. See comment 1.
Default = blank (Integer > 0 or blank)

Comments
1.

If G4 is undefined, the force is defined with respect to the ground body (that is the basic
coordinate systems).

Altair Engineering

OptiStruct 13.0 Reference Guide 1273


Proprietary Information of Altair Engineering

MBLIN
Bulk Data Entry
MBLIN Parameters for Multi-body System Linear Analysis
Description
Defines the parameters for a multi-body system linear analysis.
Format
(1)

(2)

(3)

(4)

(5)

MBLIN

ID

TYPE

ASC ALE

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MBLIN

99

EIGEN

1.0

(5)

Field

Contents

ID

Unique identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
TYPE

Type of linear analysis.


(Option "EIGEN", "STMAT")

ASCALE

Animation scale.
Default = 1.0 (Real > 0.0)

Comments
1.

This card is represented as a loadcollector in HyperMesh.

1274 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBMNT
Bulk Data Entry
MBMNT Moment for Multi-body Solution Sequence
Description
Defines a constant moment at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBMNT

SID

G1

C ID

G3/N1

N2

N3

G2

(10)

Example

(1)

(2)

(3)

MBMNT

345

(4)

(5)

(6)

(7)

(8)

100.0

0.0

1.0

0.0

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0, or blank)

Moment magnitude.
No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1275


Proprietary Information of Altair Engineering

Field

Contents

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1,N2,N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank or zero, then the force is an action-only force.
Default = 0 (Integer > 0)

Comments
1.

This card is represented as a moment load in HyperMesh.

1276 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBMNTC
Bulk Data Entry
MBMNTC Curve moment for Multi-body Solution Sequence
Description
Defines a curve moment at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBMNTC

SID

G1

C ID

C VID

G3/N1

N2

N3

G2

INT

EID

(10)

Example

(1)

(2)

(3)

MBMNTC

345

AKIMA

42

(4)

(5)

(6)

(7)

(8)

0.0

1.0

0.0

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0, or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1277


Proprietary Information of Altair Engineering

Field

Contents

CVID

Set identification number of the MBCRV entry that gives the load vs.
independent variable measured in the coordinate system defined by
CID.
(Integer > 0)

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1,N2,N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank or zero, then the force is an action-only force.
Default = 0 (Integer > 0)

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA)


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

Comments
1.

This card is represented as a moment load in HyperMesh.

1278 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBMNTE
Bulk Data Entry
MBMNTE Expression Moment for Multi-body Solution Sequence
Description
Defines an expression moment at a grid point by specifying a vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBMNTE

SID

G1

C ID

EID

G3/N1

N2

N3

G2

(10)

Example

(1)

(2)

(3)

MBMNT

345

(4)

(5)

(6)

(7)

(8)

0.0

1.0

0.0

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number where the action force is applied.


No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic


coordinate system.
Default = 0 (Integer > 0, or blank)

EID

Expression identification number of the MBVAR entry that gives the load
measured in the coordinate system defined by CID.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1279


Proprietary Information of Altair Engineering

Field

Contents

G3

Grid point identification number to optionally supply N1, N2, N3 in


conjunction with G1.
(Integer > 0)

N1, N2, N3

Defines the direction of the force vector. At least one of the vector
components must be non-zero.
Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If


blank or zero, then the force is an action-only force.
Default = 0 (Integer > 0)

1280 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBPCRV
Bulk Data Entry
MBPCRV Multi-body Parametric Curve
Description
Defines a Multi-body Parametric Curve using node sets.
Format
(1)

(2)

(3)

(4)

MBPC RV

PC ID

UC LOSE
D

C RVPTS

G1

G2

G3

(5)

(6)

G4

G5

(7)

(8)

(9)

(10)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

MBPC RV

201

202

203

204

205

Field

Contents

PCID

Parametric curve identification number.

(7)

(8)

No default (Integer > 0)


UCLOSED

Specify 1 for closed and 0 for open curves.

CRVPTS

Curve points. Specify 1 if the curve must pass through the nodes, and 0 if
the B-spline curve does not pass through the nodes, but stays close.
Default = 0 (BOOLEAN: 0,1)

G1,G2,

Ordered list of grids defining the curve.

Comments

Altair Engineering

OptiStruct 13.0 Reference Guide 1281


Proprietary Information of Altair Engineering

1.

This card is represented as a set in HyperMesh.

1282 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBPTCV
Bulk Data Entry
MBPTCV Multi-body Point to Curve Constraint
Description
Defines a Point to Parametric Curve Constraint.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MBPTC V

JID

GID

PC ID

G3

V0

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

MBPTC V

21

25

Field

Contents

JID

Joint identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


GID

Grid identification number corresponding to the point which is sliding on


a curve.
No default (Integer > 0)

PCID

Parametric curve (MBPCRV) identification number.


No default (Integer > 0)

G3

This grid specifies the guess for the initial contact point on the curve.
Default is GID (Integer > 0)

V0

Specifies the initial sliding velocity of the contact point, as measured by


an observer on the curve, placed at the contact point.
Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1283


Proprietary Information of Altair Engineering

MBPTDCV
Bulk Data Entry
MBPTDCV Multi-body Point to Deformable Curve Constraint
Description
Defines a Point to Deformable Curve Constraint.
Format
(1)

(2)

(3)

(4)

(5)

MBPTDC V

JID

GID

DC ID

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MBPTDC V

21

(5)

Field

Contents

JID

Joint identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


GID

Grid identification number corresponding to the point which is sliding on


the deformable curve.
No default (Integer > 0)

DCID

Deformable curve (MBDCRV) identification number.


No default (Integer > 0)

Comments
1.

The deformable curve is generated using the CUBIC spline interpolation which requires
assumptions on the second derivative of the interpolating function at either end of the
curve. The keywords NATURAL, PARABOLIC, PERIODIC and CANTILEVER represent the
four standard assumptions defined as follows:

1284 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Note that =0.0 implies NATURAL (or free) end conditions and =1.0 implies PARABOLIC
end conditions.
2.

The MBPTDCV element is not supported by the Force Imbalance method of static
equilibrium.

3.

In most cases, the interpolation produces a smooth curve but in some cases, it produces
a curve that wiggles too much. In those cases, the TENSION parameter may be specified
to smooth out the wiggles in the curve. A TENSION value of unity is a good first guess.
After that, higher values of TENSION may be tried if necessary.

4.

The deformable element itself does not possess any inherent inertia, stiffness or damping
properties. You must include other modeling elements to capture those effects.

Altair Engineering

OptiStruct 13.0 Reference Guide 1285


Proprietary Information of Altair Engineering

MBPTDSF
Bulk Data Entry
MBPTDSF Multi-body Dynamics Point to Deformable Surface Constraint
Description
Defines a Point to Deformable Surface Constraint.
Format
(1)

(2)

(3)

(4)

(5)

MBPTDSF

JID

GID

SRFID

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MBPTDSF

21

(5)

Field

Contents

JID

Joint identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


GID

Grid identification number corresponding to the point which is sliding on


a curve.
No default (Integer > 0)

SRFID

Deformable surface identification number


No default (Integer > 0)

Comments
1.

The deformable curve is generated using the CUBIC spline interpolation which requires
assumptions on the second derivative of the interpolating function at either end of the
curve. The keywords NATURAL, PARABOLIC, PERIODIC and CANTILEVER represent the four
standard assumptions defined as follows:

1286 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Note that =0.0 implies NATURAL (or free) end conditions and =1.0 implies PARABOLIC
end conditions.
2.

The MBPTDCV element is not supported by the Force Imbalance method of static
equilibrium.

3.

In most cases, the interpolation produces a smooth curve but in some cases, it produces
a curve that wiggles too much. In those cases, the UTENSION and VTENSION parameters
may be specified to smooth out the wiggles in the curve. A value of unity is a good first
guess. After that, higher values may be tried if necessary.

4.

The deformable surface itself does not possess any inherent inertia, stiffness or damping
properties. You must include other modeling elements to capture those effects. For
example, you may use a deformable surface in conjunction with a flexible body to simulate
contact with a rigid body.

Altair Engineering

OptiStruct 13.0 Reference Guide 1287


Proprietary Information of Altair Engineering

MBREQ
Bulk Data Entry
MBREQ Multi-body Request Combination
Description
Defines a multi-body as a combination of request sets defined via MBREQE and MBREQM.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBREQ

SID

R1

R2

R3

R4

R5

R6

R7

R8

R9

(10)

Example

(1)

(2)

(3)

(4)

(5)

MBREQ

31

34

35

(6)

Field

Contents

SID

Request set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
Ri

Request set identification numbers defined via entry typed


enumerated above.
(Integer > 0)

Comments
1.

The Ri must be unique.

2.

Request sets must be selected in the Subcase Information section (REQUEST = SID) if
they are to be applied.

1288 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBREQE
Bulk Data Entry
MBREQE Multi-body Expression Output Request
Description
Defines a multi-body solver output request to output the results of a set of expressions.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MBREQE

RSID

RID

E1

E2

E3

E4

E5

E6

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

MBREQE

235

10

20

30

40

Field

Contents

RSID

Request set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
RID

Request identification number.


(Integer > 0)

E1

ID of MBVAR.
(Integer > 0)

E2 E6

Additional MBVAR IDs.


Default = blank (blank or Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1289


Proprietary Information of Altair Engineering

Comments
1.

The request evaluates the expression at every output step.

2.

The values are always set to 0 if the expression is not specified.

3.

Request set will be specified in the subcase definition.

4.

Request ID must be unique with respect to all other MBREQM and MBREQE cards.

1290 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBREQM
Bulk Data Entry
MBREQM Multi-body Output Request based on Markers
Description
Defines a multi-body solver output request to output displacement, velocity, acceleration, or
force with respect to markers.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBREQM

RSID

RID

TYPE

IMARK

JMARK

RMARK

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBREQM

20

234

DISP

20

30

10

Field

Contents

RSID

Request set identification number.

(8)

(9)

(10)

(Integer > 0)
RID

Request identification number.


(Integer > 0)

TYPE

Output type
DIS - Displacement request
VEL - Velocity request
ACC - Acceleration request
FRC - Force request
No default

Altair Engineering

OptiStruct 13.0 Reference Guide 1291


Proprietary Information of Altair Engineering

Field

Contents

IMARK

Marker ID.
(Integer > 0) See comment 1

JMARK

Marker ID.
Default = blank; (blank or Integer > 0) See comments 1 and 2

RMARK

Reference marker ID.


Default = blank; (blank or Integer > 0) See comment 3

Comments
1.

The output request is usually of IMARK with respect to JMARK resolved in RMARK.

2.

If the JMARK is not specified, the results are with respect to global frame.

3.

If the RMARK is not specified, the results are resolved in the global frame.

4.

Request set will be specified in the subcase definition.

5.

Request ID must be unique with respect to all other MBREQM and MBREQE cards.

1292 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBSEQ
Bulk Data Entry
MBSEQ Multi-body System Simulation Sequence
Description
Defines the simulation sequence for the multi-body solver.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSEQ

ID

SID1

SID2

SID3

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

MBSEQ

99

12

43

Field

Contents

ID

Unique identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
SID1, SID2,

IDs of the simulation sequence.


(Integer > 0) (Valid IDs are: MBSIM, MBLIN, MBSIMP, MBACT, or
MBDEACT)

Comments
1.

Every time an MBSIM card is encountered, a simulation is performed on the multi-body


model. The initial condition for the next MBSIM will be the ending condition of the current
simulation.

2.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1293


Proprietary Information of Altair Engineering

MBSFRC
Bulk Data Entry
MBSFRC Scalar Load for Multi-body Solution Sequence
Description
Defines a constant scalar load on two grid points.
Format
(1)

(2)

(3)

(4)

(5)

MBSFRC

SID

G1

G2

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

MBSFRC

345

346

1.0

Field

Contents

SID

Load set identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0)

Value of load
(Real)

1294 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

MBSFRC applies a translational action-reaction force along the line of action defined by
the line segment connecting G1 and G2.

2.

The action force is applied to G1 and the reaction force is applied to G2.

3.

Tensile force is positive.

Altair Engineering

OptiStruct 13.0 Reference Guide 1295


Proprietary Information of Altair Engineering

MBSFRCC
Bulk Data Entry
MBSFRCC Curve Scalar Load for Multi-body Solution Sequence
Description
Defines a curve scalar load on two grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSFRC C

SID

G1

G2

C VID

INT

EID

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSFRC C

345

346

AKIMA

Field

Contents

SID

Load set identification number.

(8)

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0)

CVID

Set identification number of the MBCRV entry that gives the load vs.
independent variable measured in the coordinate system defined by
CID.
(Integer > 0)

1296 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

Comments
1.

MBSFRCC applies a translational action-reaction force along the line of action defined by
the line segment connecting G1 and G2.

2.

The action force is applied to G1 and the reaction force is applied to G2.

3.

Tensile force is positive.

Altair Engineering

OptiStruct 13.0 Reference Guide 1297


Proprietary Information of Altair Engineering

MBSFRCE
Bulk Data Entry
MBSFRCE Expression Scalar Load for Multi-body Solution Sequence
Description
Defines an expression scalar load on two grid points.
Format
(1)

(2)

(3)

(4)

(5)

MBSFRC E

SID

G1

G2

EID

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

MBSFRC E

345

346

Field

Contents

SID

Load set identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0

EID

Expression identification number of the MBVAR entry.


No default (Integer > 0)

1298 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

MBSFRCE applies a translational action-reaction force along the line of action defined by
the line segment connecting G1 and G2.

2.

The action force is applied to G1 and the reaction force is applied to G2.

3.

Tensile force is positive.

Altair Engineering

OptiStruct 13.0 Reference Guide 1299


Proprietary Information of Altair Engineering

MBSIM
Bulk Data Entry
MBSIM Parameters for Multi-body Simulation
Description
Defines the parameters for a multi-body simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSIM

ID

TYPE

TTYPE

TIME

STYPE

DELTA/
NSTEP/
PRINC R

ITYPE

DTOL

H0

HMAX

HMIN

VTOLFAC

DAEIDX

DC NTOL

DC RMXI
T

DC RMNI
T

DVC TRL

KETOL/
RESTOL

DQTOL/
FITOL

NITER

TLIMIT

ALIMIT

(8)

(9)

(10)

MAXODR

DJAC EVL DEVLEXP

or
STTYPE

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSIM

99

TRAN

END

5.0

NSTEPS

250

VSTIFF

0.001

0.001

0.01

1000.0

(8)

(9)

(10)

Example 2

1300 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MBSIM

99

TRAN

END

5.0

NSTEPS

250

DSTIFF

0.001

0.001

1000.0

(8)

(9)

(10)

(9)

(10)

TRUE

Example 3

(1)

(2)

(3)

MBSIM

91

STAT

1.0e-6

0.0001

(4)

(5)

(6)

(7)

(8)

100

Field

Contents

ID

Unique identification number.


(Integer > 0)

TYPE

Simulation type.
Options = ("TRANS", "STATIC")
No default

TTYPE

Termination type.
Options = ("END", "DUR") See comment 2.
No default

TIME

Termination time or duration based on TTYPE.


(Real > 0.0) See comment 2.

STYPE

Output step type.

Altair Engineering

OptiStruct 13.0 Reference Guide 1301


Proprietary Information of Altair Engineering

Field

Contents
Options = ("DELTA", "NSTEPS", "PRINCR") See comments 2 and 3.
No default

DELTA

Output time step.


(Real > 0.0) See comments 2 and 3.

NSTEPS

Maximum number of time steps.


(Integer > 0) See comments 2 and 3.

ITYPE

Integrator type.
Options = ("ABAM", "VSTIFF", "MSTIFF", "DSTIFF") See comment 4.
Default = DSTIFF

DTOL

Integrator tolerance.
Default = 0.001 (Real > 0.0) See comment 4.

H0

Initial time step for the integrator.


Default = 1e-8 (Real > 0.0) See comment 4.

HMAX

Max step size the integrator is allowed to take.


Default = 0.01 (Real > 0.0) See comment 4.

HMIN

Min step size the integrator is allowed to take.


Default = 1.0e-6 (Real > 0.0) See comment 4.

VTOLFAC

A factor that multiplies DTOL to yield the error tolerance for velocity
states.
Default = 1000 (Real > 0.0) See comment 4.

MAXODR

The maximum order that the integrator is to take.


Default depends on ITYPE (Integer > 0) See comment 4.

1302 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

DAEIDX

The index of the DAE formulation.


Default = 3 (Integer > 0) See comment 4.

DCNTOL

A tolerance on all algebraic constraint equations that the corrector


must satisfy at convergence.
Default = 0.001 (Real > 0.0) See comment 4.

DCRMXIT

The maximum number of iterations that the corrector is allowed to


take to achieve convergence.
Default = 4 (Integer > 0) See comment 4.

DCRMNIT

The minimum number of iterations that the corrector is allowed to take


before it checks for corrector divergence.
Default = 1 (Integer > 0) See comment 4.

DVCTRL

A logical flag that controls whether the velocity states are checked
for local integration error at each step.
(True or False, Default = True if DAEIDX is 3, otherwise False) See
comment 4.

DJCEVL

An attribute to control the frequency of evaluation of the Jacobian


matrix during corrector iterations.
Default is determined by MotionSolve (Integer > 0) See comment 4.

DEVLXP

The number of integration steps after which the evaluation pattern


defined by DJCEVL is ignored, and the default evaluation pattern is to
be used.
Default = 0 (Integer > 0) See comment 4.

KETOL

Maximum residual kinetic energy tolerance.


Default = 1.0e-5 (Real > 0.0) See comment 5.

RESTOL

Maximum residual tolerance for force imbalance method.


Default = 1.0e-4 (Real > 0.0) See comment 6.

Altair Engineering

OptiStruct 13.0 Reference Guide 1303


Proprietary Information of Altair Engineering

Field

Contents

DQTOL

Maximum coordinate difference tolerance.


Default = 0.001 (Real > 0.0) See comment 5.

FITOL

Maximum force imbalance tolerance.


Default = 0.001 (Real > 0.0) See comment 6.

NITER

Max number of iterations for static solution to converge.


Default = 50 (Integer > 1) See comment 5.

TLIMIT

Max translational limit for force imbalance static solution.


Default = 10000 (Real > 1) See comment 6.

ALIMIT

Max angular limit for force imbalance static solution.


Default = 30 (Real > 1) See comment 6.

STTYPE

Static solver type


Options = ("FIM", "MKM") See comments 7 and 8.
Default = MKM

Comments
1.

The continuation card is used to distinguish between either a TRANS or STAT simulation
type. The reader will look for appropriate options based on the type of simulation
specified.

2.

When the simulation type is static (STAT), the solver will perform a static simulation if the
termination type, termination time/duration, step type, delta/nsteps are not provided. A
quasi-static simulation will be performed if that information is provided.

3.

If the output step type is DELTA, then the next argument is expected to be a positive
real value, and it is the output step time during the simulation run. If the step type is
NSTEPS, then the next argument is expected to be a positive integer value which will be
the number of output steps during the simulation. If the step type is PRINCR, then the
next argument is expected to be a positive integer value which will be print increment.
Solver will output at every intermediate print increment value. If the PRINCR is set to 1,
then the solver will output intermediate results at every integrator step.

4.

ITYPE, DTOL, H0, HMAX, HMIN, VTOLFAC, MAXODR, DAEIDX, DCNTOL, DCRMXIT,
DCRMNIT, DVCTRL, DJACEVL, and DEVLEXP are only applicable for TRANS simulation types.
The 2nd continuation card (DAEIDX, DCNTOL, DCRMXIT, DCRMNIT, DVCTRL, DJACEVL,

1304 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

and DEVLEXP) are available when ITYPE = DSTIFF. See the comments in the
Param_Transient in the online help for more details.
5.

KETOL, DQTOL, NITER are only applicable for STATIC simulation type.

6.

RESTOL, FITOL, NITER, TLIMIT, ALIMIT are applicable for the force imbalance static
method used for quasi-static solutions.

7.

Static solver type is used to select from the two static solution types currently offered.
FIM represents the Force Imbalance Method and MKM represents the Maximum Kinetic
Energy Attrition Method.

8.

Note that when quasi-static simulation is requested (STAT with termination time), then
the STTYPE option is ignored and the quasi-static simulation will be performed using the
force imbalance method.

9.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1305


Proprietary Information of Altair Engineering

MBSIMP
Bulk Data Entry
MBSIMP Simulation Parameters for Subsequent Multi-body Simulation
Description
Defines the simulation parameters for subsequent multi-body simulation.
Format
(1)

(2)

(3)

(4)

(5)

MBSIMP

ID

C TOL

IDTOL

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

MBSIMP

99

0.001

1.0E-8

(5)

Field

Contents

ID

Unique identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
CTOL

Constraint tolerance.
Default = 1.0E-10 (Real > 0.0)

IDTOL

Implicit differentiation tolerance.


Default = 1.0E-6 (Real > 0.0)

Comments
1.

This card is represented as a loadcollector in HyperMesh.

1306 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBSMNT
Bulk Data Entry
MBSMNT Scalar Moment for Multi-body Solution Sequence
Description
Defines a constant scalar moment on two gird points along the specified vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNT

SID

G1

G2

G3/Vx

Vy

Vz

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNT

345

346

1.0

1.0

1.0

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0)

Value of moment.
(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1307


Proprietary Information of Altair Engineering

Field

Contents

G3

Grid point identification number to optionally supply Vx, Vy, and Vz in


conjunction with G1.
(Integer > 0)

Vx

X component of vector V.

Vy

Y component of vector V.

Vz

Z component of vector V.

Comments
1.

MBSMNT applies a scalar action-reaction moment on G1 and G2 along the vector defined
by Vx, Vy, and Vz.

2.

The action moment is applied to G1 and the reaction moment is applied to G2.

3.

Right hand rule defines the positive moment.

1308 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBSMNTC
Bulk Data Entry
MBSMNTC Curve Scalar Moment for Multi-body Solution Sequence
Description
Defines a curve scalar moment on two grid points along the specified vector.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNTC

SID

G1

G2

C VID

G3/Vx

Vy

Vz

INT

EID

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNTC

345

346

1.0

1.0

AKIMA

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1309


Proprietary Information of Altair Engineering

Field

Contents

CVID

Set identification number of the MBCRV entry that gives the load vs.
independent variable measured in the coordinate system defined by CID.
(Integer > 0)

G3

Grid point identification number to optionally supply Vx, Vy, and Vz in


conjunction with G1.
(Integer > 0)

Vx

X component of vector V.

Vy

Y component of vector V.

Vz

Z component of vector V.

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA)


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

Comments
1.

MBSCMTC applies a scalar action-reaction moment on G1 and G2 along the vector defined
by Vx, Vy, and Vz.

2.

The action moment is applied to G1 and the reaction moment is applied to G2.

3.

Right hand rule defines the positive moment.

1310 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBSMNTE
Bulk Data Entry
MBSMNTE Expression Moment for a Multi-body Solution Sequence
Description
Defines an expression scalar moment on two grid points along the specified vector
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNTE

SID

G1

G2

EID

Vx

Vy

Vz

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MBSMNTE

345

346

1.0

1.0

Field

Contents

SID

Load set identification number.

(9)

(10)

No default (Integer > 0)


G1

Grid point identification number.


No default (Integer > 0)

G2

Grid point identification number.


No default (Integer > 0)

EID

Expression identification number of the MBVAR entry.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1311


Proprietary Information of Altair Engineering

Field

Contents

G3

Grid point identification number to optionally supply Vx, Vy, and Vz in


conjunction with G1.
(Integer > 0)

Vx

X component of Vector V.

Vy

Y component of Vector V.

Vz

Z component of Vector V.

Comments
1.

MBSMNTE applies a scalar action-reaction moment on G1 and G2 along the vector defined
by Vx, Vy, and Vz.

2.

The action moment is applied to G1 and the reaction moment is applied to G2.

3.

Right hand rule defines the positive moment.

1312 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MBVAR
Bulk Data Entry
MBVAR Multi-body Solver Variable
Description
Defines a multi-body solver variable which can be referred to by multiple Expressions.
Format
(1)

(2)

MBVAR

VID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

EXPR

Example

(1)

(2)

MBVAR

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

IMPAC T(Dz(30301020,30302040),VZ(30301020,30302040),0.0,4
00,1.0,0.5,0.000)

Field

Contents

VID

Variable identification number.


(Integer > 0)

EXPR

Character string expression. The expression can spawn multiple lines. The
continuation lines will start from the second column. Refer to Function
Expressions.

Comments
1.

The variable ID can be referenced by VARVAL(VID) in multiple expressions in the model.

Altair Engineering

OptiStruct 13.0 Reference Guide 1313


Proprietary Information of Altair Engineering

METADATA
Bulk Data Entry
METADATA Indicates the beginning of metadata that is to be passed to the metadata
output file.
Description
METADATA indicates the beginning of metadata that is to be passed to the metadata output
file. Metadata between the METADATA and ENDMETADATA commands is passed to the
<filename>_metadata.xml file.

Example

METADATA
This line will be passed to the filename_metadata.xml file.
So will this information: Color=blue
ENDMETADATA
Comments
1.

There can be two sections of metadata; one in the Solution Control section and one in
the Bulk Data section.

2.

Metadata can be used to pass information from the pre-processor seamlessly through the
solver to a post-processing program.

1314 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MFLUID
Bulk Data Entry
MFLUID Fluid Volume
Description
Defines the parameters and damp shell elements for a fluid volume.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MFLUID

SID

C ID

ZFS

RHO

WSURF1

WSURF2

PLANE1

PLANE2

RMAX

Example

(1)

(2)

MFLUID

25

(3)

(4)

(5)

(6)

32.0

42.0

45

Field

Contents

SID

Unique set of identification numbers.

(7)

(8)

(9)

(10)

No default (Integer > 0)


CID

Coordinate system identification number in which its z-axis is assumed to


be normal to the free surface.
Default = 0 (Integer > 0, or blank)

ZFS

Location of the free surface on the z-axis of the CID coordinate system.
Default = 1030 (Real)

RHO

Fluid density.

Altair Engineering

OptiStruct 13.0 Reference Guide 1315


Proprietary Information of Altair Engineering

Field

Contents
No default (Real > 0.0)

WSURF1

Set identification number of a SURF or SET bulk data entry. This list
identifies shell elements that are damp on only one side of the element or
an exterior face of solid elements (see SURF,ELFACE).
Default = 0 (Integer > 0, or blank)

WSURF2

Set identification number of a SURF or SET bulk data entry. This list
identifies shell elements that are damp on both sides of the element.
Default = 0 (Integer > 0, or blank)

PLANE1

Type of symmetry on x-z plane of fluid coordinate system (CID).


N - no symmetry
S - symmetric
A - antisymmetric
Default = N (Character = N, S, A)

PLANE2

Type of symmetry on y-z plane of fluid coordinate system (CID).


N - no symmetry
S - symmetric
A - antisymmetric
Default = N (Character = N, S, A)

RMAX

Interaction between two elements is ignored, if the distance between


them is greater than RMAX.
Default = 1010 (Real > 0.0)

Comments
1.

An MFLUID entry must be selected by the MFLUID = SID command in the Subcase
Information section.

2.

More than one MFLUID entry may be specified to define multiple fluid volumes.

3.

Either WSURF1 or WSURF2, or both must be specified and non-zero. In other words,
WSURF1 and WSURF2 cannot be both blank or zero.

4.

An element with all its vertices located on or above the free surface will be ignored in the
fluid volumes mass calculation. An element vertex is considered to be located on the free
surface, if the vertex is located within a distance that is

1316 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

from the free surface.


5.

By default for elements referenced by WSURF1, the damp side of the element is assumed
to be on the same side as the elements normal. If this condition is not true for a given
element, then the standard SURF entry format with ELFACE (not the alternative SET
format) must be used to redefine the normal into the fluid by setting NORMAL=1 on SURF
entry.

6.

ELIST is an alternative to SET and SURF, but ELIST is intended only to provide
compatibility with Nastran decks and therefore is considered deprecated. Also,
The SURF and SET entries may not be combined with ELIST entries to define damp
elements.
ELIST entries are internally converted to SET entries. If ELIST is used, then all MFLUID
entries must reference ELIST entries. This means that if an MFLUID references a
missing ELIST,25, then the program will not search for a SET,25.

7.

Planes of symmetry may be defined with PLANE1 and PLANE2.


"S means zero displacement normal to the plane.
A means zero pressure normal to the plane.
Consistent structural boundary conditions should be applied to grids located on the
planes of symmetry.
If PLANE1 is S or A, then all damp elements must not cross the X-Z plane and be
on the same side of the X-Z plane as all other damp elements.
If PLANE2 is S or A, then all damp elements must not cross the Y-Z plane and be
on the same side of the Y-Z plane as all other damp elements.

8.

Dry mode output in the .out file is available only when PARAM,VMOPT,2 is specified.

Altair Engineering

OptiStruct 13.0 Reference Guide 1317


Proprietary Information of Altair Engineering

MGASK
Bulk Data Entry
MGASK Gasket Material Property Definition
Description
Defining the material properties for gasket-like materials.
Format 1 (no temperature dependency)
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MGASK

MID

BEHAV

YPRS

EPL

GPL

ALPHA

EPLTYPE GPLUNIT

TABLD

TABLU1

TABLU2

TABLU3

TABLU4

TABLU5

TABLU6

TABLU7

(8)

(9)

(10)

TABLU8

Format 2 (temperature dependency defined)


(1)

(2)

(3)

(4)

(5)

(6)

(7)

MGASK

MID

BEHAV

YPRS

EPL

GPL

ALPHA

EPLTYPE GPLUNIT

TABLD

TABLU1

TABLU2

TABLU3

TABLU4

TABLU5

TABLU6

TABLU7

TABLU8

TABLU9

-etc.-

"T"

TEMP1

YPRS

EPL

GPL

ALPHA

TABLU3

TABLU4

TABLU5

TABLU6

TABLU7

"PLUS"

TABLD

TABLU1

TABLU2

TABLU8

TABLU9

-etc.-

"T"

TEMP2

(10)

-etc.-

1318 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MGASK

1.0e-3

200.0

1.0e-5

1001

1002

1003

1004

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MGASK

1.0e-3

200.0

1.0e-5

1001

1002

20.0

(8)

(9)

(10)

(8)

(9)

(10)

Example 2

1003

1004

2003

2004

PLUS

2001

2002

100.0

2005

PLUS

3001

3002

300.0

3003

Field

Contents

MID

Material identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1319


Proprietary Information of Altair Engineering

Field

Contents

BEHAV

Behavior type. See comment 12.


Default = 0 (Integer (0 or 1 only))
0 elasto-plastic material
1 elastic material with damage

YPRS

Initial yield pressure for the thickness direction of the gasket material.
Applies only to elasto-plastic behavior (BEHAV=0).
If blank, it is determined automatically.
For the groups of data starting with PLUS, default is the corresponding
field value defined at the first line.

EPL

Tension stabilization coefficient or direct tensile modulus (depends on the


value of the EPLTYPE field) for the thickness direction of the gasket
material. See comment 5.
Default = 0.0 (Real > 0.0)
For the groups of data starting with PLUS, default is the corresponding
field value defined at the first line.

GPL

Transverse shear modulus of the gasket material (the unit of measure


depends on the value of the GPLUNIT field).
Default = 0.0 (Real > 0.0)
For the groups of data starting with PLUS, default is the corresponding
field value defined at the first line.

ALPHA

Coefficient of thermal expansion in the normal direction.


Default = 0.0 (Real > 0.0)
For the groups of data starting with PLUS, default is the corresponding
field value defined at the first line.

EPLTYPE

Type of definition of EPL. See comment 12.


Default = 0 (Integer (0 or 1 only))
0 EPL is defined as a tension stabilization coefficient
1 EPL is defined as a direct tensile modulus

GPLUNIT

Type of the unit of measure of GPL. See comment 12.


Default = 0 (Integer (0 or 1 only))

1320 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
0 stress per unit displacement
1 force per unit area

TABLD

Identifier of a TABLES1 table providing loading path of the gasket material


(pressure vs. closure).
No default (Integer > 0)

TABLUi

Identifier of TABLES1 table providing unloading/reloading path of the


gasket material (pressure vs. closure). If there is no unloading, leave the
fields blank.
Default = blank (Integer > 0 or blank)

Temperature flag indicating that a temperature value will be defined in the


next field.

TEMPj

Temperature for the group of data above. See comment 11.


No default (Real)

PLUS

Keyword indicating that the following is a group of data defined at another


temperature. See comment 12.

Comments
1.

The material identification number must be unique for all MAT1, MAT2, MAT3, MAT8,
MAT9 and MGASK entries.

2.

MGASK mainly defines nonlinear properties in the thickness direction for gasket-like
materials under compression. MGASK has anisotropy only in the thickness direction, which
is called normal anisotropy. For linear analysis, the thickness-direction modulus (stress
per unit displacement) is defined by the slope of the first segment of the loading
pressure-closure curve TABLD.

3.

MGASK also defines the transverse shear and thickness-direction tension behaviors with
linear properties. (The membrane properties of the gasket are defined by a MAT1,
referenced from the PGASK property.)

4.

The thickness direction of gasket material is the principal direction (local 3-direction) in
3D solids.

5.

If EPL is defined as a tension stabilization coefficient (EPLTYPE = 0), the tensile modulus
will be calculated as the initial slope of the first segment of the loading curve TABLD
multiplied by EPL. If EPL is defined as a direct tensile modulus (EPLTYPE = 1), its unit of
measure is stress per unit displacement. If EPL is zero, a small tensile modulus will be used
automatically for stabilization (no matter EPLTYPE is 0 or 1).

6.

All the data points in tables TABLD and TABLUi are specified in the first quadrant. Points

Altair Engineering

OptiStruct 13.0 Reference Guide 1321


Proprietary Information of Altair Engineering

on loading (TABLD) and unloading/reloading (TABLUi) paths must be defined in order of


increasing pressure and distance.
7.

For elasto-plastic material (BEHAV = 0),


The initial yield pressure should match a point in table TABLD. If the initial yield
pressure is not specified, it will be determined automatically by finding the first point on
the TABLD curve where the slope changes by more than 10%.
The loading path starts from the origin to initial yield pressure (nonlinear elastic range)
and continues with strain hardening slope into the plastic region.
All unloading/reloading paths must start with zero pressure and positive closure
distance, and end at the loading path in the plastic region. Subsequent unloading/
reloading curves must start with larger closure distances (when pressure is zero) and
end with larger closure distances than previous unloading/reloading curves.

8.

For elastic material with damage (BEHAV = 1),


All loading and unloading/reloading curves must start at the origin of the coordinate
system (0, 0).
All unloading/reloading paths must end at the loading path. Subsequent unloading/
reloading curves must end with larger closure distances than previous unloading/
reloading curves.

9.

Unloading/reloading behavior at undefined paths will be interpolated between two


adjacent unloading/reloading paths.

10. For closures larger than the last user-specified closure, the pressure-closure relationship
is calculated as follows:
For elasto-plastic material (BEHAV = 0), it follows the last segment of the furthest
unloading/reloading curve. This behavior is fully elastic and represents crushed gasket.
For elastic material with damage (BEHAV = 1), it follows last slope computed from the
user-specified data.

1322 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Elasto-plastic gasket material

Elastic gasket material with damage

11. If temperature dependency is defined, TEMPj should be provided in ascending order and
the loading path (and unloading/reloading paths, if required) should be provided for each

Altair Engineering

OptiStruct 13.0 Reference Guide 1323


Proprietary Information of Altair Engineering

temperature. If temperature dependency is defined but the temperature field for material
property is not provided, the first group of data will be used to calculate the material
property. TEMPj are defined for all MGASK data fields (data groups) that lie between the
respective TEMPj and its previous PLUS field. TEMP1 is an exception to this rule as it is
defined for all data fields that lie between itself and MID.
Example

12. BEHAV, EPLTYPE and GPLUNIT fields after any PLUS field should remain blank because
their values are always the same as those of the first-group data.

1324 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MLOAD
Bulk Data Entry
MLOAD Multi-body Load Combination
Description
Defines a multi-body as a linear combination of load sets defined via GRAV, MBFRC, MBFRCC,
MBFRCE, MBMNT, MBMNTC, MBMNTE, MBSFRC, MBSFRCC, MBSFRCE, MBSMNT, MBSMNTC, and
MBSMNTE.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MLOAD

SID

L1

L2

L3

L4

L5

L6

L7

L8

L9

(10)

Example

(1)

(2)

(3)

(4)

(5)

MLOAD

31

34

35

Field

Contents

SID

Load set identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
Li

Load set identification numbers defined via entry typed enumerated above.
(Integer > 0)

Comments
1.

The Li must be unique.

2.

Load sets must be selected in the Subcase Information section (MLOAD = SID) if they are
to be applied.

Altair Engineering

OptiStruct 13.0 Reference Guide 1325


Proprietary Information of Altair Engineering

3.

An MLOAD entry may not reference a set identification number defined by another MLOAD
entry.

4.

This card is represented as a loadcollector in HyperMesh.

1326 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOMENT
Bulk Data Entry
MOMENT Static Moment
Description
Defines a static moment at a grid point by specifying a vector. It can also be used to define
the EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2
bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOMENT

SID

C ID

N1

N2

N3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOMENT

2.9

0.0

1.0

0.0

Field

Contents

SID

Load set identification number.

(9)

(10)

(Integer > 0)
G

Grid point identification number.


(Integer > 0 or <PartName.number>) See comment 3.

CID

Coordinate system identification number.


(Integer > 0 or blank)

Scale factor.

Altair Engineering

OptiStruct 13.0 Reference Guide 1327


Proprietary Information of Altair Engineering

Field

Contents
(Real)

N1,N2,N3

Components of vector measured in coordinate system defined by CID.


(Real; at least one non-zero component)

Comments
1.

The static moment applied to grid point G is given by

where,

is the vector defined in fields 6, 7, and 8.

2.

A CID of zero or blank references the basic coordinate system.

3.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on MOMENT entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN Bulk Data Entry in the model). number is the identification number of a
referenced local entry in the part PartName. See Parts and Instances in the Users
Guide for detailed information on the use of fully qualified references.

4.

This card is represented as a moment load in HyperMesh.

1328 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOMENT1
Bulk Data Entry
MOMENT1 Static Moment, Alternate Form 1
Description
Defines a static moment by specification of a value and two grid points, which determine the
direction. It can also be used to define the EXCITEID field (Amplitude A) of dynamic loads in
RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

MOMENT1

SID

G1

G2

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

MOMENT1

13

-2.93

16

13

Field

Contents

SID

Load set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
G

Grid point identification number.


(Integer > 0)

Value of moment.
(Real)

G1,G2

Grid point identification numbers.

Altair Engineering

OptiStruct 13.0 Reference Guide 1329


Proprietary Information of Altair Engineering

Comments
1. The static moment applied to grid point G is

where,

is a unit vector parallel to a vector from G1 to G2.

2. This card is represented as a moment load in HyperMesh.

1330 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOMENT2
Bulk Data Entry
MOMENT2 Static Moment, Alternate Form 2
Description
Defines a static moment by specification of a value and four grid points, which determine the
direction. It can also be used to define the EXCITEID field (Amplitude A) of dynamic loads in
RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOMENT2

SID

G1

G2

G3

G4

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOMENT2

13

-2.93

16

13

18

19

Field

Contents

SID

Load set identification number.

(9)

(10)

(Integer > 0)
G

Loaded grid point identification number.


(Integer > 0)

Value of moment.
(Real)

G1,G2

Grid point identification numbers.


(Integer > 0; G1 and G2 cannot coincident; G3 and G4 cannot be
coincident)

Altair Engineering

OptiStruct 13.0 Reference Guide 1331


Proprietary Information of Altair Engineering

Comments
1.

The static moment applied to grid point G is

where,
is a unit vector parallel to a vector calculated from the cross product of the
vectors from G1 to G2 and G3 to G4.
2.

This card is represented as a moment load in HyperMesh.

1332 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTION
Bulk Data Entry
MOTION Multi-body Motion Combination
Description
Defines a multi-body as a combination of motion sets defined via MOTNJ, MOTNJC, MOTNJE,
MOTNG, MOTNGC, and MOTNGE.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MOTION

SID

M1

M2

M3

M4

M5

M6

M7

M8

M9

(10)

Example

(1)

(2)

(3)

(4)

(5)

MOTION

31

34

35

Field

Contents

SID

Motion set identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
Mi

Motion set identification numbers defined via entry typed enumerated


above.
(Integer > 0)

Comments
1.

The Mi must be unique.

2.

Motion sets must be selected in the Subcase Information section (MOTION=SID) if they
are to be applied.

Altair Engineering

OptiStruct 13.0 Reference Guide 1333


Proprietary Information of Altair Engineering

3.

This card is represented as a loadcollector in HyperMesh.

1334 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNG
Bulk Data Entry
MOTNG Constant Grid Point Motion for Multi-body Solution Sequence
Description
Defines a constant grid point motion.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNG

SID

G1

C1

G2

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

MOTNG

345

Field

Contents

SID

Load set identification number.

(5)

(6)

(7)

(8)

(9)

(10)

1.0

(Integer > 0)
G1

Grid point identification number.


(Integer > 0)

C1

Component number (Integer 1 through 18). The component refers to the


direction and type of motion of the grid point G1 in the Basic Coordinate
System (not the Local Coordinate System).

G2

Grid point identification number to define relative motion.


(Integer > 0 or blank)

Scale factor.

Altair Engineering

OptiStruct 13.0 Reference Guide 1335


Proprietary Information of Altair Engineering

(Real)
D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

If G1 and G2 are defined, the motion is a relative motion between the two grid points; if
G2 is blank, absolute motion of G1 is defined.

2.

The types and directions of motion for the component numbers are given in the following
table.
Component Number(s)

Type of Motion

Direction(s) of Motion

1, 2, and 3

Displacement

X, Y, Z

4, 5, and 6

Rotation

X, Y, Z

7, 8, and 9

Translational Velocity

X, Y, Z

10, 11, and 12

Angular Velocity

X, Y, Z

13, 14, and 15

Translational Acceleration

X, Y, Z

16, 17, and 18

Angular Acceleration

X, Y, Z

The component numbers and directions of motion are in the format: 1->X, 2->Y and 3->Z
for Displacement and this format is followed for all the types in the table.
3.

This card is represented as a constraint load in HyperMesh.

1336 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNGC
Bulk Data Entry
MOTNGC Grid Point Motion vs. Time Curve for Multi-body Solution Sequence
Description
Defines a grid point motion vs. time by specifying a curve.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNGC

SID

G1

C1

G2

C VID

INT

EID

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

MOTNGC

345

Field

Contents

SID

Load set identification number.

(5)

(6)

(7)

(8)

AKIMA

(9)

(10)

(Integer > 0)
G1

Grid point identification number.


(Integer > 0)

C1

Component number (Integer 1 through 18). The component refers to the


direction and type of motion of the grid point G1 in the Basic Coordinate
System (not the Local Coordinate System).

G2

Grid point identification number to define relative motion.


(Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1337


Proprietary Information of Altair Engineering

Field

Contents

CVID

Set identification number of the MBCRV entry that gives the motion vs.
time.
(Integer > 0)

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

If G1 and G2 are defined, the motion is a relative motion between the two grid points; if
G2 is blank, absolute motion of G1 is defined.

2.

The types and directions of motion for the component numbers are given in the following
table.
Component Number(s)

Type of Motion

Direction(s) of Motion

1, 2, and 3

Displacement

X, Y, Z

4, 5, and 6

Rotation

X, Y, Z

7, 8, and 9

Translational Velocity

X, Y, Z

10, 11, and 12

Angular Velocity

X, Y, Z

13, 14, and 15

Translational Acceleration

X, Y, Z

16, 17, and 18

Angular Acceleration

X, Y, Z

The component numbers and directions of motion are in the format: 1->X, 2->Y and 3->Z
for Displacement and this format is followed for all the types in the table.
3.

This card is represented as a constraint load in HyperMesh.

1338 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNGE
Bulk Data Entry
MOTNGE Expression Grid Point Motion for Multi-body Solution Sequence
Description
Defines a grid point motion through an expression.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNGE

SID

G1

C1

G2

EID

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

MOTNGE

345

Field

Contents

SID

Load set identification number.

(5)

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
G1

Grid point identification number.


(Integer > 0)

C1

Component number (Integer 1 through 18). The component refers to the


direction and type of motion of the grid point G1 in the Basic Coordinate
System (not the Local Coordinate System).

G2

Grid point identification number to define relative motion.


(Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1339


Proprietary Information of Altair Engineering

Field

Contents

EID

Expression identification number of the MBVAR entry that gives the motion
vs. time.
(Integer > 0)

D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

A CID of zero or blank references the basic coordinate system.

2.

The types and directions of motion for the component numbers are given in the following
table.
Component Number(s)

Type of Motion

Direction(s) of Motion

1, 2, and 3

Displacement

X, Y, Z

4, 5, and 6

Rotation

X, Y, Z

7, 8, and 9

Translational Velocity

X, Y, Z

10, 11, and 12

Angular Velocity

X, Y, Z

13, 14, and 15

Translational Acceleration

X, Y, Z

16, 17, and 18

Angular Acceleration

X, Y, Z

The component numbers and directions of motion are in the format: 1->X, 2->Y and 3->Z
for Displacement and this format is followed for all the types in the table.

1340 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNJ
Bulk Data Entry
MOTNJ Constant Joint Motion for Multi-body Solution Sequence
Description
Defines a constant joint motion.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNJ

SID

JID

MTYPE

DTYPE

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

MOTNJ

345

TRANS

1.0

DIS

Field

Contents

SID

Load set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
JID

Joint identification number.


(Integer > 0)

MTYPE

TRANS or ROT, ignored for revolute and translational joints.

Value of motion.
(Real)

DTYPE

Motion data type (DIS or VEL or ACC), blank means displacement


motion.

Altair Engineering

OptiStruct 13.0 Reference Guide 1341


Proprietary Information of Altair Engineering

Field

Contents

D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

Joint motion can only be applied to cylindrical joints (MTYPE = TRANS or ROT), revolute
joints (MTYPE = ROT), and translational joints (MTYPE = TRANS).

1342 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNJC
Bulk Data Entry
MOTNJC Joint Motion vs. Time Curve for Multi-body Solution Sequence
Description
Defines a joint motion vs. time by specifying a curve.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNJC

SID

JID

MTYPE

C VID

INT

EID

DTYPE

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MOTNJC

345

ROT

AKIMA

99

Field

Contents

SID

Load set identification number.

(8)

(9)

(10)

(Integer > 0)
JID

Grid point identification number.


(Integer > 0)

MTYPE

TRANS or ROT, ignored for revolute and translational joints.

CVID

Set identification number of the MBCRV entry that gives the motion vs.
time.
(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1343


Proprietary Information of Altair Engineering

Field

Contents

INT

Interpolation type (Character: LINEAR, CUBIC, AKIMA).


Default = AKIMA

EID

Set identification number of the MBVAR for the independent variable


expression.
Default = TIME (Integer > 0 or blank)

DTYPE

Motion data type (DIS or VEL or ACC), blank means displacement motion.

D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

Joint motion can only be applied to cylindrical joints (MTYPE = TRANS or ROT), revolute
joints (MTYPE = ROT), and translational joints (MTYPE = TRANS).

1344 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MOTNJE
Bulk Data Entry
MOTNJE Expression Joint Motion for Multi-body Solution Sequence
Description
Defines a joint motion through an expression.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MOTNJE

SID

JID

MTYPE

EID

DTYPE

D0

V0

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

MOTNJE

345

Field

Contents

SID

Load set identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
JID

Joint identification number.


(Integer > 0)

MTYPE

TRANS or ROT, ignored for revolute and translational joints.

EID

Expression identification number of the MBVAR entry that gives the


motion vs. time. If blank or zero, a constant motion of D is applied.
Default = constant motion D (Integer > 0 or blank)

DTYPE

Motion data type (DIS or VEL or ACC), blank means displacement

Altair Engineering

OptiStruct 13.0 Reference Guide 1345


Proprietary Information of Altair Engineering

Field

Contents
motion.

D0

Initial displacement if motion data is of type velocity or acceleration,


ignored otherwise.

V0

Initial velocity if motion data type is acceleration, ignored otherwise.

Comments
1.

Joint motion can only be applied to cylindrical joints (MTYPE = TRANS or ROT), revolute
joints (MTYPE = ROT), and translational joints (MTYPE = TRANS).

1346 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MPC
Bulk Data Entry
MPC Multipoint Constraint
Description
The MPC bulk data entry defines a multipoint constraint equation of the form.

Aj u j

Where,

Aj

is the coefficient that can be used to define the relationship between the degrees of
freedom associated with grid points (or a scalar point) in the model.

uj

is the degree of freedom associated with a grid point (or a scalar point).

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MPC

SID

blank

blank

-etc.-

blank

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

MPC

28

6.2

4.29

-2.91

Field

Contents

SID

Set identification number.

Altair Engineering

(9)

(10)

OptiStruct 13.0 Reference Guide 1347


Proprietary Information of Altair Engineering

Field

Contents
(Integer > 0)

Identification number of a grid point or a scalar point.


(Integer > 0 or <PartName.number>) See comment 5.

Component number. See comment 3.


(Integer zero or blank for scalar points, or any one of the digits 1-6 for grid
points)

Coefficient that can be used to define the relationship between the degrees of
freedom associated with grid points (or a scalar point).
(Real; the first A must be non-zero)

Comments
1.

The first coordinate in the sequence is assumed to be the dependent coordinate. A


dependent degree-of-freedom assigned by one MPC entry cannot be assigned dependent
by another MPC entry or by a rigid element.

2.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

3.

The component refers to the coordinate system referenced by the grid point.

4.

Illustrative Example:
Figure 1 can be used to illustrate an MPC application. Independent grid points G1 and G2
of a 2D quad element are connected with the help of an MPC; where Gd is the dependent
grid point. The objective of this example is to force the displacement of Gd to be equal to
the sum of the displacements of grid points G1 and G2 in the X (1) direction using an
MPC.

1348 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure : MPC Example Illustration

Rewriting the MPC equation for three grid points:

A1u1

A2 u2

A3 u3

Substituting A1 = 1.0, A2 = -1.0 and A3 = -1.0 in the equation above:

(1.0)ud

( 1.0)u1

( 1.0)u2

Rearranging equation terms:

ud

u1

u2

Where,

ud
u1
u2

is the displacement of grid point Gd in X direction


is the displacement of grid point G1 in X direction
is the displacement of grid point G2 in X direction

5.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on MPC entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

6.

This card is represented as an equation in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1349


Proprietary Information of Altair Engineering

MPCADD
Bulk Data Entry
MPCADD Multipoint Constraint Set Combination
Description
Defines a multipoint constraint set as a union of multipoint constraint sets defined via MPC
entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MPC ADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

etc.

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

MPC ADD

101

Field

Contents

SID

Set identification number.

(8)

(9)

(10)

(Integer > 0)
Sj

Set identification numbers of multipoint constraint sets defined via MPC


entries.
(Integer > 0 or <PartName.number>) See comment 5.

Comments
1.

Multipoint constraint sets must be selected with the Subcase Information command
MPC=SID.

2.

The Sj field should not reference the identification number of a multipoint constraint set

1350 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

defined by another MPCADD entry.


3.

MPCADD entries take precedence over MPC entries. If both have the same SID, only the
MPCADD entry will be used.

4.

If all Si are non-existent, the solver will exit with an error termination.

5.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on MPCADD entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN Bulk Data Entry in the model). number is the identification number of a
referenced local entry in the part PartName. See Parts and Instances in the Users
Guide for detailed information on the use of fully qualified references.

6.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1351


Proprietary Information of Altair Engineering

NLOAD
Bulk Data Entry
NLOAD Nonlinear Load Combination or Superposition
Description
Defines a loading condition for nonlinear problems as a linear combination of load sets defined
via NLOAD1.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NLOAD

SID

S1

L1

S2

L2

S3

L3

S4

L4

...

...

...

...

...

...

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NLOAD

1.0

2.0

101

2.0

102

2.0

103

-2.0

201

Field

Contents

SID

Load set identification number.

(10)

No default (Integer > 0)


S

Scale factor.
No default (Real)

Si

Scale factors.
No default (Real)

1352 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Li

Load set identification numbers of NLOAD1.


No default (Integer > 0)

Comments
1.

Dynamic load sets must be selected in the I/O Options or Subcase Information sections
with NLOAD=SID.

2.

The load vector being defined by this entry is given by:

.
3.

Each Li must be unique from any other Li on the same entry.

4.

SID must be unique from all NLOAD1 entries.

5.

An NLOAD entry may not reference a set identification number defined by another NLOAD
entry.

6.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1353


Proprietary Information of Altair Engineering

NLOAD1
Bulk Data Entry
NLOAD1 Time Dependent Load or Motion for Geometric Nonlinear Analysis
Description
Defines a time-dependent load or enforced motion for use in geometric nonlinear analysis.

f(t) = A * C * F(t/B)
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NLOAD1

SID

EXC ITEID

SENSID

TYPE

TID

C ID

TSTART

TEND

(10)

Example

(1)

(2)

(3)

NLOAD1

(4)

(5)

(6)

LOAD

13

Field

Contents

SID

Load set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
EXCITEID SID number of DAREA, SPCD or static load set that defines A. See
comments 2 and 3.
(Integer > 0)
SENSID

Identification number of a sensor. Load application is activated once the


referenced sensor is activated.

1354 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Integer > 0)

TYPE

Defines the type of the dynamic excitation. See comments 2 and 3.


Default = 0 (Integer, character or blank)

TID

Identification number of TABLEDi entry defining the load history F(t).


(Integer > 0)
TID=0 implies F(t) is a linear function passing through (TTERM-TTERMS, 0)
and (TTERM, 1). TTERMS is the duration of each subcase. TTERM is the
termination time. TID = 0 is only for geometric nonlinear implicit (quasi-)
static analysis (NLGEOM).

Scale factor of the time in f(t).


Default = 1.0 (Real > 0)

Scale factor for the function value in f(t).


Default = 1.0 (Real)

CID

Identification number of coordinate system defining a frame in which the


imposed velocity is defined. Applies only for TYPE = 2, V, VE, VEL, or VELO.
Only CORD1R and CORD2R systems are allowed.
(Integer > 0 or blank)

TSTART

Start time. See comment 4.


Default = 0.0 (Real > 0.0)

TEND

End time.
Default = 1030 (Real > TSTART)

Comments
1.

Time-dependent load sets must be selected with the Subcase Information command
NLOAD = SID. It can only be selected in geometric nonlinear analysis subcases which are
defined by an ANALYSIS = NLGEOM, IMPDYN or EXPDYN subcase entry.

2.

The type of the dynamic excitation is specified by TYPE (field 5) according to the
following table:

Altair Engineering

OptiStruct 13.0 Reference Guide 1355


Proprietary Information of Altair Engineering

TYPE

TYPE of Dynamic Excitation

O, L, LO, LOA, or LOAD

Applied load (force, moment, pressure).


(Default)

3.

1, D, DI, DIS, or DISP

Enforced displacement using SPC/SPCD data.

2, V, VE, VEL, or VELO

Enforced velocity using SPC/SPCD data.

3, A, AC, ACC, or ACCE

Enforced acceleration using SPC/SPCD data

TYPE (field 5) also determines the manner in which EXCITEID (field 3) is used by the
program as described below.
Excitation specified by TYPE is applied load. The EXCITEID may reference DAREA, or
(and) static load set entries. If EXCITEID references both DAREA and static load set,
the two loads will be super-imposed.
Excitation specified by TYPE is enforced motion. The EXCITEID must reference SPCD
entries.

4.

TSTART and TEND are only considered for enforced displacement, velocity, and
acceleration. The continuation line is optional.

5.

This card is represented as a loadcollector in HyperMesh.

1356 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NLPARM
Bulk Data Entry
NLPARM Parameters for Nonlinear Static Analysis or Heat Transfer Analysis
Description
The NLPARM bulk data entry defines parameters for nonlinear static analysis or heat transfer
analysis solution control.
Format
(1)

(2)

(3)

(4)

NLPARM

ID

NINC

EPSU

EPSP

(5)

(6)

(7)

(8)

KSTEP

MAXITER

C ONV

EPSW

(9)

MAXLS

(10)

LSTOL

Example

(1)

(2)

(3)

NLPARM

99

(4)

(5)

(6)

(7)

Field

Contents

ID

Each NLPARM bulk data card must have a unique ID.

(8)

(9)

(10)

No default (Integer > 0)


NINC

Number of implicit load sub-increments (see comments 2 and 3).


Default = 1 (no increments) for ANALYSIS = NLSTAT and ANALYSIS=NLHEAT
Default = 10 for ANALYSIS = NLGEOM
(Integer > 0)

KSTEP

Number of iterations before stiffness update (see comment 3).


Default = 6 for ANALYSIS = NLGEOM and BCS solver

Altair Engineering

OptiStruct 13.0 Reference Guide 1357


Proprietary Information of Altair Engineering

Field

Contents
Default = 3 for ANALYSIS = NLGEOM and PCG solver
(Integer > 0)

MAXITER

Limit on number of implicit iterations for each load increment. If reached, the
solution is terminated (ANALYSIS = NLSTAT and ANALYSIS=NLHEAT).
Default = 25 (Integer > 0)

CONV

Flags to select implicit convergence criteria.


Default = UPW for ANALYSIS = NLSTAT
Default = PW for ANALYSIS = NLGEOM
(Any combination of U, P and W)

EPSU

Error tolerance for displacement (U) criterion.


Default = 1.0E-3 for ANALYSIS = NLSTAT
Default = 1.0E-2 for ANALYSIS = NLGEOM
(Real > 0.0)

EPSP

Error tolerance for load (P) criterion.


Default = 1.0E-3 for ANALYSIS = NLSTAT and ANALYSIS=NLHEAT
Default = 1.0E-2 for ANALYSIS = NLGEOM
(Real > 0.0)

EPSW

Error tolerance for work (W) criterion.


Default = 1.0E-7 for ANALYSIS = NLSTAT and ANALYSIS=NLHEAT
Default = 1.0E-3 for ANALYSIS = NLGEOM
(Real > 0.0)

MAXLS

Maximum number of line searches allowed for each iteration.


Default = 20 (Integer > 0)

1358 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

LSTOL

Line search tolerance.


Default = 1.0E-3 (Real > 0.0)

Comments
1.

The NLPARM bulk data entry is selected by the Subcase Information command
NLPARM=option. Each subcase for which nonlinear analysis is desired requires an NLPARM
command.

2.

The solution method for quasi-static nonlinear analysis (ANALYSIS = NLSTAT) is full
Newton. The stiffness matrix is updated at each iteration. NINC > 0 represents the
number of equal subdivisions that the total load in a given subcase will be divided into. If
NINC is blank, the entire load for a given subcase is applied at once. The Newton method
will be applied to consecutive load levels until the final load is reached.

3.

Additional control for geometric nonlinear implicit static solution schemes (ANALYSIS =
NLGEOM) can be defined using the NLPARMX bulk data entry. Defaults will be used if
NLPARMX is not present.

4.

The solution method for geometric nonlinear implicit analysis (ANALYSIS = NLGEOM) is
modified or Quasi-Newton. The frequency of stiffness matrix updates is controlled by
KSTEP. For highly nonlinear problems, it is recommended to reduce KSTEP for better
performance. KSTEP = 1 means full Newton.
If the loading is defined using NLOAD, the termination time TTERM must defined by a
TTERM subcase entry. The initial implicit time step is TTERMS/NINC with TTERMS =
TTERM T0. All subsequent time steps will be determined automatically. In a simulation
with multiple nonlinear subcases, T0 is the end time of the previous load step. If there is
only a single nonlinear subcase, T0 = 0.0.
If the loading is defined using LOAD, TTERM is not mandatory. These loads are treated as
linear ramp-up. If TTERM is defined, the load ramps up from the end time of the previous
subcase to TTERM. If TTERM is absent, it will be determined from the subcase sequence
such that the duration of each subcase TTERMS = 1.0. In this case, the initial time step
is 1.0/NINC.

5.

For Nastran compatibility, NLPCI is imported if present. Only the fields ID, TYPE are
interpreted. With NLPCI present, the default for NLPARMX, SACC will be reset to RIKS.
TYPE will be translated into CTYPE; all other entries are set to default. A warning will be
issued. NLPCI and NLPARMX cannot be used simultaneously. It is recommended to remove
NLPCI and use NLPARMX with the appropriate definitions.

6.

For more information about nonlinear quasi-static analysis, see the Nonlinear Quasi-static
Analysis section.

7.

For more information about geometric nonlinear analysis, see the Geometric Nonlinear
Analysis section.

8.

For more information about nonlinear steady-state heat transfer analysis, see the
Nonlinear Steady-State Heat Transfer Analysis section.

Altair Engineering

OptiStruct 13.0 Reference Guide 1359


Proprietary Information of Altair Engineering

9.

This card is represented as a loadcollector in HyperMesh.

1360 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NLPARMX
Bulk Data Entry
NLPARMX Optional Parameters for Geometric Nonlinear Implicit Static Analysis Control
Description
Defines additional parameters for geometric nonlinear implicit static analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NLPARMX

ID

TA0

DTA

DTTH

NPRINT

RFILE

SOLV

TSC TRL

DTMIN

DTMAX

LSMETH

KINER

DTSC Q

ILIN

SMDISP

SPRBK

ITW

DTSC I

LDTN

DTSC D

LARC

(10)

RREFIF

NC YC LE

FIXTID/
TOUT

C TYP

WSC AL

Example 1

(1)

(2)

NLPARM

99

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example 2

(1)

(2)

NLPARM

99

NLPARMX

99

NEWT

Altair Engineering

0.1

ARC

1.e-4

0.1

OptiStruct 13.0 Reference Guide 1361


Proprietary Information of Altair Engineering

Example 3

(1)

(2)

NLPARM

99

0.01

NLPARMX

(3)

(5)

(6)

(7)

0.01

99

NEWT

(4)

(8)

(9)

(10)

PW

0.01

0.1

ARC

1.e-4

0.1

NEWM

0.25

0.5

Field

Contents

ID

Identification number of an associated NLPARM entry.


No default (Integer > 0)

TA0

Start time for writing animation files.


Default = 0.0 (Real > 0)

DTA

Output time step for animation files. If zero, no output (See comment 3).
Default = DTINI (Real > 0)

DTTH

Output time step for time history files. If zero, no output (See comment 3).
Default = 0.1*DTINI (Real > 0)

NPRINT

Print every NPRINT iterations. If negative, to .out and standard output; if


positive, only to .out file.
Default = -1 (Integer)

RFILE

Cycle frequency to write restart file for nonlinear iteration.


Default = 5000 (Integer > 0)

1362 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

SOLV

Geometric nonlinear implicit solution method.


NEWT Modified Newton
BFGS BFGS quasi-Newton method
Default = NEWT (Character = NEWT or BFGS)

TSCTRL

Time step control.


ARC Arc-length is used to accelerate and control the convergence. The
time step is determined by displacement norm control (arc-length).
SIMP Simple time step control.
RIKS Riks method for post-buckling analysis (only with SOLV = NEWT).
NONE No time step control. A warning will be issued. In the case of
divergence the time step will be repeated with half the step size. The run
will be terminated according to DTMIN and NCYCLE.
Default = ARC (Character)

DTMIN

Minimum implicit time step. If DTMIN is reached, simulation will be terminated


(See comment 3).
Default = 1e-4*DTINI (Real > 0)

DTMAX

Maximum implicit time step from which time step is set constant (See
comment 3).
Default = 3*DTINI (Real > 0)

LSMETH

Line search method.


Default = ENERGY (Character = NONE, FORCE, ENERGY, or AUTO)

RREFIF

Special residual force computation with contact interfaces present.


Default = no special treatment (Integer = 0, , 5)
0
1
2
3

Aggressive (modified entirely by the out-of-balance value)


Average (modified each time with 200% maximum)
Light (modified each time with 20% maximum)
No modification

Altair Engineering

OptiStruct 13.0 Reference Guide 1363


Proprietary Information of Altair Engineering

Field

Contents
4 No modification; except for the first contact.
5 Modified automatically (for imposed displacement only)

NCYCLE

Maximum number of time steps. If reached, solution will be terminated.


NCYCLE = 0 means no limit.
Default = no limit (Integer > 0)

FIXTID

Identification number of a TABLEDi entry. The x values of the table define


fixed time points that the automatic time step control will adhere to.
(Integer > 0)

TOUT

The method to determine the fixed time point.


AUTO Fully automatic time step control.
NLOAD - The time points in all TABLEDi that are referenced by NLOAD1 in one
subcase.
Default = AUTO (AUTO or NLOAD)

KINER

Inertia Stiffness for handling models that are not sufficiently constrained.
May require definition of DTSCQ (See comment 4).
Default = OFF (Character = ON, OFF)

DTSCQ

Scale factor for inertia stiffness matrix used in quasi-static analysis (KINER =
ON, See comment 4).
Default = 1.0 (Real > 0)

ILIN

Perform linear instead of nonlinear analysis. For debugging purposes.


(ANALYSIS = NLGEOM, See comment 5).
LIN Linear analysis without contact.
LINC Linear analysis with contact.
Default is nonlinear analysis (Character = LIN, LINC)

SMDISP

Perform small displacement and rotation analysis instead of geometric


nonlinear analysis. PARAM, SMDISP, 1 overwrites this definition.
OFF Geometric nonlinear analysis.

1364 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
ON Small displacements and small rotations analysis.
Default = OFF (Character = ON, OFF)

SPRBK

Perform spring back analysis. Equilibrium is reached when the internal forces
are less or equal to the tolerances given on NLPARM.
OFF Regular analysis.
ON Spring back analysis.
Default = OFF (Character = ON, OFF)

ITW

If the solution of a time step converges within ITW iterations the next time
step will be increased by a factor controlled by DTSCI.
Default = 6 for TSCTRL = ARC
Default = 2 for TSCTRL = SIMP
Default = 12 for TSCTRL = RIKS
Default = 6 (Integer > 0)

DTSCI

Maximum scale factor for increasing the time step (TSCTRL = ARC, RIKS).
Scale factor for TSCTRL = SIMP.
Default = 1.1 (Real > 0)

LDTN

Maximum number of iterations before resetting and decreasing the time step
by a factor of DTSCD.
Default = 20 for TSCTRL = ARC
Default = 15 for TSCTRL = SIMP
Default = 25 for TSCTRL = RIKS
(Integer > 0)

DTSCD

Scale factor for decreasing the time step (TSCTRL = ARC, SIMP, RIKS).
Default = 0.67 (Real > 0)

LARC

Input arc-length for TSCTRL = ARC, RIKS

Altair Engineering

OptiStruct 13.0 Reference Guide 1365


Proprietary Information of Altair Engineering

Field

Contents
Default = automatic computation (Real)

CTYP

Constraint type (See comment 6).


CRIS Crisfield constraint equation.
MFSRIKS - Modified Forde & Stiemer equation.
Default = CRIS (CRIS or MFSRIKS)

WSCAL

Scale factor for controlling the loading contribution in the constraint


equation.
Default = 0.0 (Real > 0.0)

Comments
1.

The NLPARMX bulk data entry is selected by the Subcase Information command NLPARM =
option. There must also be an NLPARM bulk data entry with the same ID. It is only used
in geometric nonlinear implicit static analysis (ANALYSIS = NLGEOM); it is ignored in other
analyses.

2.

The solution method for geometric nonlinear implicit analysis is selected by SOLV. The
frequency of stiffness matrix updates is controlled by KSTEP. For highly nonlinear
problems, it is recommended to reduce KSTEP for better performance. KSTEP = 1 means
full Newton.

3.

If the loading is defined using NLOAD, the termination time TTERM must be defined by a
TTERM subcase entry. The initial implicit time step is DTINI = TTERMS/NINC with TTERMS
= TTERM T0. All subsequent time steps will be determined automatically. In a
simulation with multiple nonlinear subcases, T0 is the end time of the previous load step.
If there is only a single nonlinear subcase, T0 = 0.0.
If the loading is defined using LOAD, TTERM is not mandatory. These loads are treated as
linear ramp-up. If TTERM is defined, the load ramps up from the end time of the previous
subcase to TTERM. If TTERM is absent, it will be determined from the subcase sequence
such that the duration of each subcase TTERMS = 1.0. In this case, the initial time step
is DTINI = 1.0/NINC.

4.

For models that are not sufficiently constrained, inertia stiffness can be used to overcome
a singular stiffness matrix. The inertia stiffness [K]inertia = 1/(DTSCQ*dt)^2[M] is added
to the stiffness matrix [K]. Care needs to be taken in the selection of DTSCQ. Too large
of an added mass may lead to wrong results.

5.

Linear static and normal modes analysis within geometric nonlinear analysis (ILIN = LIN,
LINC) are provided for debugging purposes. They may help detecting modeling errors. All
materials are linearized, and linear displacements are assumed as well. The load is taken
at the termination time. To run normal modes analysis, a METHOD subcase entry that
refers to an EIGL bulk data entry must be provided.

1366 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

The constraint equation for CTYP = CRIS is:

Where, u is displacement, j the scale factor (WSCAL) , l a load factor, and r the arclength.
The constraint equation for CTYP = MFSRIKS is:

Where,
is the displacement, due to a unit load factor, and
is the displacement
increment from the conventional Newton type method. The meaning of u, j, l, and r are
the same as those above.
7.

For Nastran compatibility, NLPCI is imported if present. Only the fields ID, TYPE are
interpreted. With NLPCI present, the default for TSCTRL will be reset to RIKS. TYPE will
be translated into CTYP; all other entries are set to default. A warning will be issued.
NLPCI and NLPARMX cannot be used simultaneously. It is recommended to remove NLPCI
and use NLPARMX with the appropriate definitions

8.

For more information about geometric nonlinear analysis, see the Geometric Nonlinear
Analysis section.

9.

This card is represented as an extension to an NLPARMX loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1367


Proprietary Information of Altair Engineering

NLPCI
Bulk Data Entry
NLPCI Implicit Time Step Control for Riks Type Arc-Length Method
Description
Define implicit automatic time step control with Riks type arc-length method.
Format
(1)

(2)

(3)

(4)

NLPC I

ID

TYPE

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

NLPC I

C RIS

(4)

(5)

(6)

(7)

Field

Contents

ID

Identification number of an associated NLPARM entry.

(8)

(9)

(10)

No default (Integer > 0)


TYPE

Constraint type
Default = CRIS (CRIS, RIKS, or MRIKS)

Comments
1.

The NLPCI bulk data entry is selected by the Subcase Information command NLPARM =
option. There must also be an NLPARM entry with the same ID. It is only used in
geometric nonlinear (quasi-)static analysis (ANALYSIS = NLGEOM).

2.

NLPCI is implemented for Nastran compatibility and imported if present. Only the fields ID,
TYPE are interpreted. With NLPCI present, the default for NLPARMX, SACC will be reset
to RIKS. TYPE will be translated into CTYPE; all other entries are set to default. A
warning will be issued. NLPCI and NLPARMX cannot be used simultaneously. It is

1368 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

recommended to remove NLPCI and use NLPARMX with the appropriate definitions.
3.

This card is an unsupported bulk data entry in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1369


Proprietary Information of Altair Engineering

NLRGAP
Bulk Data Entry
NLRGAP Nonlinear Load Proportional to Gap
Description
Defines a nonlinear radial (circular) gap for direct transient response analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NLRGAP

SID

GA

GB

PLANE

TABK

TABG

TABU

RADIUS

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NOLIN1

21

XY

10

1.6

Field

Contents

SID

Nonlinear load set identification number.

(10)

No default (Integer > 0)


GA

Inner grid for radial gap (shaft).


No default (Integer > 0)

GB

Outer grid for radial gap (housing).


No default (Integer > 0)

PLANE

Radial gap orientation plane.


Default = XY (XY, YZ or ZX)

TABK

Table ID defining either (See comment 11):


Gap stiffness vs. time

1370 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Gap force vs. penetration
No default (Integer > 0)

TABG

Table ID for radial gap clearance as a function of time.


No default (Integer > 0)

TABU

Table ID for radial coefficient of friction as a function of time.


No default (Integer > 0)

RADIUS

Shaft radius.
Default = 0.0 (Real > 0.0)

Comments
1.

Nonlinear radial gap must be selected by the Subcase Information data selector
NONLINEAR.

2.

Multiple NLRGAP entries with the same SID are allowed.

3.

The NLRGAP is not an element, but a nonlinear load similar to the NOLIN1, NOLIN2, NOLIN3
and NOLIN4 entries. It computes the relative displacements of GA and GB in the selected
plane and applies appropriate nonlinear loads to simulate the radial contact.

4.

The degrees of freedom in the XY, YZ and ZX planes (depending on the PLANE defined) of
GA and GB must be members of the solution set. This means that they must not be
dependent degrees of freedom and the must not have SPCs applied to them. If RADIUS is
> 0.0, then the in-plane rotation degree of freedom must also be in the solution set.

5.

The NLRGAP is limited to use in direct transient response analysis.

6.

The XY, YZ and ZX planes are relative to the displacement coordinate systems of GA and
GB.

7.

GA and GB must both be grid points, they must both be coincident, and they must have
parallel displacement coordinate systems. If any of these conditions are not met, an error
termination will occur.

8.

The shaft radius is used only for the computation of friction induced torque.

9.

A positive coefficient of friction is consistent with a counter-clockwise shaft rotation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1371


Proprietary Information of Altair Engineering

10. The time step algorithm in transient solution sequences may loose unconditional stability
when this load entry is used. In most practical cases, the time step size chosen to reach
a certain accuracy is below the stability limit. It is recommended to decrease the time
step if results diverge.
11. If the integer entered in the TABK field is positive, it is the ID of a TABLED1 entry defining
time vs. gap stiffness. If the integer is negative, then the absolute value of the integer is
the ID of a TABLED1 entry defining gap penetration vs. gap force.
12. Forces due to TABK and TABU at GA and GB are only present when the gap is closed. A
moment is applied only when the gap is closed and RADIUS > 0.0.

1372 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NOLIN1
Bulk Data Entry
NOLIN1 Nonlinear Transient Load as a Tabular Function
Description
Defines nonlinear transient forcing functions of the form

Function of displacement:

Function of velocity:

where,

and

are the displacement and velocity at point GJ in the direction of CJ.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NOLIN1

SID

GI

CI

GJ

CJ

TID

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NOLIN1

21

2.1

10

Field

Contents

SID

Nonlinear load set identification number.

(9)

(10)

No default (Integer > 0)


GI

Grid or scalar point identification number at which nonlinear load is to be


applied.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1373


Proprietary Information of Altair Engineering

Field

Contents

CI

Component number for GI.


No default (1 < Integer < 6; blank or 0 if GI is a scalar point)

Scale factor.
No default (Real)

GJ

Grid or scalar point identification number.


No default (Integer > 0)

CJ

Component number for GJ, according to the following table:

TID

Type

Displacement

Velocity

Grid

1 < Integer < 6

11 < Integer < 16

Scalar

Blank or 0

Integer = 10

Identification number of a TABLED1, TABLED2, TABLED3, or TABLED4 entry.


No default (Integer > 0)

Comments
1.

Nonlinear loads must be selected by the Subcase Information data selector NONLINEAR.

2.

Nonlinear loads may not be referenced on a DLOAD entry.

3.

All degrees-of-freedom referenced on NOLIN1 entries must be members of the solution


set.

4.

Nonlinear loads as a function of velocity are denoted by components ten greater than the
actual component number; that is the component 11 indicates velocity in the 1
component direction. The velocity is determined by:

where,
is the time step interval and
previous time step.
5.

is the displacement of GJ-CJ for the

The time step algorithm in transient solution sequences may loose unconditional stability

1374 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

when this load entry is used. In most practical cases, the time step size chosen to reach
a certain accuracy is below the stability limit. It is recommended to decrease the time
step if results diverge.

Altair Engineering

OptiStruct 13.0 Reference Guide 1375


Proprietary Information of Altair Engineering

NOLIN2
Bulk Data Entry
NOLIN1 Nonlinear Transient Load as the Product of Two Variables
Description
Defines nonlinear transient forcing functions of the form

where,
and
can be either displacement or velocity at points GJ and GK,
respectively, in the directions of CJ and CK, respectively.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NOLIN2

SID

GI

CI

GJ

CJ

GK

CK

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NOLIN2

14

2.9

Field

Contents

SID

Nonlinear load set identification number.

(9)

(10)

No default (Integer > 0)


GI

Grid or scalar point identification number at which nonlinear load is to be


applied.
No default (Integer > 0)

CI

Component number for GI.

1376 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
No default (1 < Integer < 6; blank or 0 if GI is a scalar point)

Scale factor.
No default (Real)

GJ, GK

Grid or scalar point identification number.


No default (Integer > 0)

CJ, CK

Component number for GJ, GK according to the following table:


Displacement

Velocity

Grid

1 < Integer < 6

11 < Integer < 16

Scalar

Blank or 0

Integer = 10

Type

Comments
1.

Nonlinear loads must be selected by the Subcase Information data selector NONLINEAR.

2.

Nonlinear loads may not be referenced on a DLOAD entry.

3.

All degrees-of-freedom referenced on NOLIN2 entries must be members of the solution


set.

4.

GI-CI, GJ-CJ and GK-CK may be the same degree-of-freedom.

5.

Nonlinear loads may be a function of displacement


or velocity
.
Velocities are denoted by a component number ten greater than the actual component
number; that is the component 11 indicates velocity in the 1 component direction. The
velocity is determined by:

where,
is the time step interval and
previous time step.
6.

is the displacement of GJ-CJ or GK-CK for the

The time step algorithm in transient solution sequences may loose unconditional stability
when this load entry is used. In most practical cases, the time step size chosen to reach
a certain accuracy is below the stability limit. It is recommended to decrease the time
step if results diverge.

Altair Engineering

OptiStruct 13.0 Reference Guide 1377


Proprietary Information of Altair Engineering

NOLIN3
Bulk Data Entry
NOLIN1 Nonlinear Transient Load as a Positive Variable Raised to a Power
Description
Defines nonlinear transient forcing functions of the form

where,

may be a displacement or a velocity at point GJ in the direction of CJ.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NOLIN3

SID

GI

CI

GJ

CJ

(9)

(10)

Example

(1)

(2)

(3)

NOLIN3

102

(4)

(5)

(6)

(7)

(8)

-6.1

15

-3.5

Field

Contents

SID

Nonlinear load set identification number.

(9)

(10)

No default (Integer > 0)


GI

Grid or scalar point identification number at which nonlinear load is to be


applied.
No default (Integer > 0)

CI

Component number for GI.

1378 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
No default (1 < Integer < 6; blank or 0 if GI is a scalar point)

Scale factor.
No default (Real)

GJ

Grid or scalar point identification number.


No default (Integer > 0)

CJ

Component number for GJ, GK according to the following table:

Type

Displacement

Velocity

Grid

1 < Integer < 6

11 < Integer < 16

Scalar

Blank or 0

Integer = 10

Exponent of the forcing function.


No default (Real)

Comments
1.

Nonlinear loads must be selected by the Subcase Information data selector NONLINEAR.

2.

Nonlinear loads may not be referenced on a DLOAD entry.

3.

All degrees-of-freedom referenced on NOLIN3 entries must be members of the solution


set.

4.

Nonlinear loads may be a function of displacement


or velocity
.
Velocities are denoted by components ten greater than the actual component number;
that is the component 11 indicates velocity in the 1 component direction. The velocity is
determined by:

where,
is the time step interval and
previous time step.

Altair Engineering

is the displacement of GJ-CJ for the

OptiStruct 13.0 Reference Guide 1379


Proprietary Information of Altair Engineering

5.

Use a NOLIN4 entry for the negative range of

6.

The time step algorithm in transient solution sequences may loose unconditional stability
when this load entry is used. In most practical cases, the time step size chosen to reach
a certain accuracy is below the stability limit. It is recommended to decrease the time
step if results diverge.

1380 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

NOLIN4
Bulk Data Entry
NOLIN1 Nonlinear Transient Load as a Negative Variable Raised to a Power
Description
Defines nonlinear transient forcing functions of the form

where,

may be a displacement or a velocity at point GJ in the direction of CJ.

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NOLIN4

SID

GI

CI

GJ

CJ

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

NOLIN4

2.0

101

Field

Contents

SID

Nonlinear load set identification number.

(7)

(8)

(9)

(10)

16.3

No default (Integer > 0)


GI

Grid or scalar point identification number at which nonlinear load is to be


applied.
No default (Integer > 0)

CI

Component number for GI.

Altair Engineering

OptiStruct 13.0 Reference Guide 1381


Proprietary Information of Altair Engineering

Field

Contents
No default (1 < Integer < 6; blank or 0 if GI is a scalar point)

Scale factor.
No default (Real)

GJ

Grid or scalar point identification number.


No default (Integer > 0)

CJ

Component number for GJ, GK according to the following table:

Type

Displacement

Velocity

Grid

1 < Integer < 6

11 < Integer < 16

Scalar

Blank or 0

Integer = 10

Exponent of the forcing function.


No default (Real)

Comments
1.

Nonlinear loads must be selected by the Subcase Information data selector NONLINEAR.

2.

Nonlinear loads may not be referenced on a DLOAD entry.

3.

All degrees-of-freedom referenced on NOLIN4 entries must be members of the solution


set.

4.

Nonlinear loads may be a function of displacement


or velocity
.
Velocities are denoted by components ten greater than the actual component number;
that is the component 11 indicates velocity in the 1 component direction. The velocity is
determined by

where,
is the time step interval and
previous time step.

is the displacement of GJ-CJ for the

1382 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

Use a NOLIN3 entry for the positive range of

6.

The time step algorithm in transient solution sequences may loose unconditional stability
when this load entry is used. In most practical cases, the time step size chosen to reach
a certain accuracy is below the stability limit. It is recommended to decrease the time
step if results diverge.

Altair Engineering

OptiStruct 13.0 Reference Guide 1383


Proprietary Information of Altair Engineering

NSM
Bulk Data Entry
NSM Non-structural Mass per Unit Area or per Unit Length
Description
Defines non-structural mass per unit area or per unit length for a list of elements or
properties.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSM

SID

TYPE

ID

VALUE

ID

VALUE

ID

VALUE

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSM

PSHELL

155

0.06

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSM

ELEMENT

12

0.03

13

0.03

14

0.03

Example 2

Field

Contents

SID

Identification number of non-structural mass set.


No default (Integer > 0)

TYPE

This can be one of the properties PSHELL, PCOMP, PBAR, PBARL, PBEAM,
PBEAML, PROD, CONROD, PSHEAR, or PTUBE, in which case the list of IDs will

1384 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
refer to properties of the stated type, or it can be ELEMENT, in which case the
list is of individual element IDs of elements that can have NSM.
No default (PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD,
PSHEAR, PTUBE, or ELEMENT).

ID

Property or Element ID, depending on the TYPE definition


No default (Integer > 0)

VALUE

Non-structural mass per unit area or per unit length


No default (Real)

Comments
1.

Refer to the User's Guide section on Non-structural Mass for more information on the use
of this card.

2.

Non-structural mass in this format must be selected by the NSM Subcase Information
selector.

Altair Engineering

OptiStruct 13.0 Reference Guide 1385


Proprietary Information of Altair Engineering

NSM1
Bulk Data Entry
NSM1 Non-structural Mass per Unit Area or per Unit Length, Alternate Form 1
Description
Defines non-structural mass per unit area or per unit length for a list of elements or
properties.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NSM1

SID

TYPE

VALUE

ID

ID

ID

ID

ID

ID

ID

ID

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

NSM1

ELEMENT

0.063

(7)

(8)

(9)

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

(7)

NSM1

SID

TYPE

VALUE

ID

THRU

ID

NSM1

PSHELL

0.03

THRU

12

Field

Contents

SID

Identification number of non-structural mass set.

(8)

1386 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(9)

(10)

Altair Engineering

No default (Integer > 0)


TYPE

This can be one of the properties PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML,
PROD, CONROD, PSHEAR, or PTUBE, in which case the list of IDs will refer to
properties of the stated type, or it can be ELEMENT, in which case the list is of
individual element IDs of elements that can have NSM.
No default (PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD,
PSHEAR, PTUBE, or ELEMENT).

VALUE

Non-structural mass per unit area or per unit length


No default (Real)

ID

Property or Element ID, depending on the TYPE definition


No default (Integer > 0, or "THRU")

Comments
1.

Refer to the User's Guide section on Non-structural Mass for more information on the use
of this card.

2.

Non-structural mass in this format must be selected by the NSM Subcase Information
selector.

Altair Engineering

OptiStruct 13.0 Reference Guide 1387


Proprietary Information of Altair Engineering

NSMADD
Bulk Data Entry
NSMADD Non-structural Mass Set Combination
Description
Defines non-structural mass as the sum of the sets listed.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NSMADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

S10

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

NSMADD

100

200

(5)

(6)

Field

Contents

SID

Identification number of non-structural mass set.

(7)

(8)

(9)

(10)

No default (Integer > 0)


S#

Identification number of nonstructural mass sets defined via NSM, NSM1, NSML,
and NSML1 entries.

VALUE

A lumped mass value to be distributed over all the listed elements and elements
referencing listed properties.
No default (Real)

1388 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

ID

Property or Element ID, depending on the TYPE definition


No default (Integer > 0, or "THRU")

Comments
1.

Refer to the User's Guide section on Non-structural Mass for more information on the use
of this card.

2.

Non-structural mass in this format must be selected by the NSM Subcase Information
selector.

3.

No S# may be the identification number of a non-structural mass set defined by another


NSMADD entry.

4.

NSMADD entries take precedence over NSM, NSML, NSM1 or NSML1 entries. If both have
the same SID, only the NSMADD entry will be used.

Altair Engineering

OptiStruct 13.0 Reference Guide 1389


Proprietary Information of Altair Engineering

NSML
Bulk Data Entry
NSML Lumped Non-structural Mass
Description
Defines lumped non-structural mass for a list of elements or properties.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NSML

SID

TYPE

ID

VALUE

ID

VALUE

ID

VALUE

Example

(1)

(2)

(3)

(4)

(5)

NSML

PSHELL

16

0.29

(6)

Field

Contents

SID

Identification number of non-structural mass set.

(7)

(8)

(9)

(10)

No default (Integer > 0)


TYPE

This can be one of the properties PSHELL, PCOMP, PBAR, PBARL, PBEAM,
PBEAML, PROD, CONROD, PSHEAR, or PTUBE, in which case the list of IDs will
refer to properties of the stated type, or it can be ELEMENT, in which case the
list is of individual element IDs of elements that can have NSM.
No default (PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD,
PSHEAR, PTUBE, or ELEMENT).

ID

Property or Element ID, depending on the TYPE definition


No default (Integer > 0)

1390 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

VALUE

A lumped mass value to be distributed over all the listed elements and elements
referencing listed properties.
No default (Real)

Comments
1.

Refer to the User's Guide section on Non-structural Mass for more information on the use
of this card.

2.

Non-structural mass in this format must be selected by the NSM Subcase Information
selector.

3.

This entry will calculated an equivalent non-structural mass per unit area or per unit
length using the lumped mass values provided.
For "area" elements, the calculation is:

and for "line" elements, the calculation is:

4.

You cannot mix "area" and "line" elements on the same entry. The "area" elements are:
CQUAD4, CQUAD8, CTRIA3, CTRIA6, and CSHEAR; and the "line" elements are: CBAR,
CBEAM, CTUBE, CROD, and CONROD.

Altair Engineering

OptiStruct 13.0 Reference Guide 1391


Proprietary Information of Altair Engineering

NSML1
Bulk Data Entry
NSML1 Lumped Non-structural Mass, Alternate Form 1
Description
Defines lumped non-structural mass for a list of elements or properties.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

NSML

SID

TYPE

VALUE

ID

ID

ID

ID

ID

ID

ID

ID

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

NSML

ELEMENT

0.06

(9)

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

(7)

NSML

SID

TYPE

VALUE

ID

THRU

ID

NSML

ELEMENT

0.06

THRU

Field

Contents

SID

Identification number of non-structural mass set.

(8)

(9)

(10)

No default (Integer > 0)

1392 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

TYPE

This can be one of the properties PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML,
PROD, CONROD, PSHEAR, or PTUBE, in which case the list of IDs will refer to
properties of the stated type, or it can be ELEMENT, in which case the list is of
individual element IDs of elements that can have NSM.
No default (PSHELL, PCOMP, PBAR, PBARL, PBEAM, PBEAML, PROD, CONROD,
PSHEAR, PTUBE, or ELEMENT).

VALUE

A lumped mass value to be distributed over all the listed elements and elements
referencing listed properties.
No default (Real)

ID

Property or Element ID, depending on the TYPE definition


No default (Integer > 0, or "THRU")

Comments
1.

Refer to the User's Guide section on Non-structural Mass for more information on the use
of this card.

2.

Non-structural mass in this format must be selected by the NSM Subcase Information
selector.

3.

This entry will calculated an equivalent non-structural mass per unit area or per unit
length using the lumped mass values provided.
For "area" elements, the calculation is:

and for "line" elements, the calculation is:

4.

You cannot mix "area" and "line" elements on the same entry. The "area" elements are:
CQUAD4, CQUAD8, CTRIA3, CTRIA6, and CSHEAR; and the "line" elements are: CBAR,
CBEAM, CTUBE, CROD, and CONROD.

Altair Engineering

OptiStruct 13.0 Reference Guide 1393


Proprietary Information of Altair Engineering

PAABSF
Bulk Data Entry
PAABSF Frequency-Dependant Fluid Acoustic Absorber Property
Description
Defines the properties of the fluid acoustic absorber element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PAABSF

PID

TZREID

TSIMID

RHOC

Example

(1)

(2)

(3)

(4)

(5)

(6)

PAABSF

1.0

0.5

Field

Contents

PID

Property identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
TZREID

Identification of the TABLEDi entry that defines the resistance as a function of


frequency. The real part of the impedance.
(Integer > 0 or Blank)

TZIMID

Identification of the TABLEDi entry that defines the reactance as a function of


frequency. The imaginary part of impedance.
(Integer > 0 or Blank)

Impedance scale factor.


Default = 1.0 (Real)

1394 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Area factor when 1 or 2 grid points are specified in the CAABSF entry.
Default = 1.0 (Real > 0.0)

Equivalent damping coefficient.


Default = 0.0 (Real)

Equivalent stiffness coefficient.


Default = 0.0 (Real)

RHOC

Constant used in data recovery for calculating an absorption coefficient. RHO is


the media density and C is the speed of sound in the media.
Default = 1.0; current unused (Real)

Input File - mdcaabsf.parm


$$
$$ Optistruct Input Deck Generated by HyperMesh Version : 10.0build60
$$ Generated using HyperMesh-Optistruct Template Version : 10.0-SA1-120
$$
$$
Template: optistruct
$$
$$
$
DISPLACEMENT(PHASE) = 1
OUTPUT,HGFREQ,ALL
OUTPUT,OPTI,ALL
OUTPUT,H3D,ALL
OUTPUT,PUNCH,ALL
$$------------------------------------------------------------------------------$
$$
Case Control Cards
$
$$------------------------------------------------------------------------------$
$
$HMNAME LOADSTEP
1"Piston_Load"
6
$
SUBCASE
1
LABEL Piston_Load
SPC =
12
METHOD(STRUCTURE) =
4
METHOD(FLUID) =
5
FREQUENCY =
3
DLOAD =
9
XYPUNCH DISP 1/
11(T1)
XYPUNCH DISP 1/
43(T1)
XYPUNCH DISP 1/
55(T1)
XYPUNCH DISP 1/
67(T1)
XYPUNCH DISP 1/
79(T1)
XYPUNCH DISP 1/
91(T1)
XYPUNCH DISP 1/
103(T1)
XYPUNCH DISP 1/
115(T1)

Altair Engineering

OptiStruct 13.0 Reference Guide 1395


Proprietary Information of Altair Engineering

XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
XYPUNCH
$
$HMSET
SET 1 =

DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP
DISP

1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/

127(T1)
139(T1)
151(T1)
163(T1)
175(T1)
187(T1)
199(T1)
531(T1)
543(T1)
555(T1)
567(T1)
579(T1)
591(T1)
603(T1)
615(T1)
627(T1)
639(T1)
651(T1)
663(T1)
675(T1)
687(T1)

1
1 "pressure"
43,55,67,79,91,103,115,
127,139,151,163,175,187,199,
531,543,555,567,579,591,603,
615,627,639,651,663,675,687,
6798

$
$$-------------------------------------------------------------$$ HYPERMESH TAGS
$$-------------------------------------------------------------$$BEGIN TAGS
$$END TAGS
$
BEGIN BULK
ACMODL
$$
$$ Stacking Information for Ply-Based Composite Definition
$$
PARAM,AUTOSPC,YES
PARAM,POST,-1
$$
$$ DESVARG Data
$$
$$
$$ GRID Data
$$
GRID
9
GRID
10
GRID
11
GRID
12
GRID
13
GRID
14
GRID
15
GRID
16
GRID
17
GRID
18
GRID
19
GRID
20
GRID
21
GRID
22
GRID
23
GRID
24
GRID
25
GRID
26

0.492
0.246
0.0
-0.246
-0.492
-0.492
-0.492
-0.246
0.0
0.246
0.492
0.492
0.0
-0.246
0.246
0.492
0.492
0.246

0.0
0.0
0.0
0.0
0.0
0.246
0.492
0.492
0.492
0.492
0.492
0.246
0.246
0.246
0.246
-0.246
-0.492
-0.492

-1.72-15
-8.59-16
0.0
8.589-16
1.718-15
1.718-15
1.718-15
8.589-16
0.0
-8.59-16
-1.72-15
-1.72-15
0.0
8.589-16
-8.59-16
-1.72-15
-1.72-15
-8.59-16

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1396 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95

Altair Engineering

0.0
-0.492 0.0
-0.246 -0.492 8.589-16
-0.492 -0.492 1.718-15
-0.492 -0.246 1.718-15
0.0
-0.246 0.0
0.246
-0.246 -8.59-16
-0.246 -0.246 8.589-16
0.246
5.049-29-.300073
-5.99-130.0
-.300073
-5.62-130.246
-.300073
0.246
0.246
-.300073
0.246
2.524-29-.600146
-1.2-12 0.0
-.600146
-1.12-120.246
-.600146
0.246
0.246
-.600146
0.246
2.919-29-0.90022
-1.79-120.0
-.900219
-1.68-120.246
-.900219
0.246
0.246
-0.90022
0.246
3.787-29-1.20029
-2.39-120.0
-1.20029
-2.24-120.246
-1.20029
0.246
0.246
-1.20029
0.246
4.733-29-1.50037
-3.0-12 0.0
-1.50037
-2.81-120.246
-1.50037
0.246
0.246
-1.50037
0.246
5.364-29-1.80044
-3.6-12 0.0
-1.80044
-3.37-120.246
-1.80044
0.246
0.246
-1.80044
0.246
6.311-29-2.10051
-4.2-12 0.0
-2.10051
-3.93-120.246
-2.10051
0.246
0.246
-2.10051
0.246
7.258-29-2.40059
-4.79-120.0
-2.40059
-4.49-120.246
-2.40059
0.246
0.246
-2.40059
0.246
8.204-29-2.70066
-5.39-120.0
-2.70066
-5.06-120.246
-2.70066
0.246
0.246
-2.70066
0.246
8.835-29-3.00073
-5.99-120.0
-3.00073
-5.62-120.246
-3.00073
0.246
0.246
-3.00073
0.246
9.782-29-3.30081
-6.59-120.0
-3.30081
-6.18-120.246
-3.30081
0.246
0.246
-3.30081
0.246
1.073-28-3.60088
-7.19-120.0
-3.60088
-6.74-120.246
-3.60088
0.246
0.246
-3.60088
0.246
1.136-28-3.90095
-7.78-120.0
-3.90095
-7.3-12 0.246
-3.90095
0.246
0.246
-3.90095
0.246
1.231-28-4.20102
-8.38-120.0
-4.20102
-7.86-120.246
-4.20102
0.246
0.246
-4.20102
0.246
1.294-28-4.5011
-8.99-120.0
-4.5011
-8.43-120.246
-4.5011
0.246
0.246
-4.5011
0.246
1.388-28-4.80117
-9.59-120.0
-4.80117

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1397


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164

-8.99-120.246
-4.80117
0.246
0.246
-4.80117
0.246
1.452-28-5.10124
-1.02-110.0
-5.10124
-9.55-120.246
-5.10124
0.246
0.246
-5.10124
0.246
1.515-28-5.40132
-1.08-110.0
-5.40132
-1.01-110.246
-5.40132
0.246
0.246
-5.40132
0.246
1.609-28-5.70139
-1.14-110.0
-5.70139
-1.07-110.246
-5.70139
0.246
0.246
-5.70139
0.246
1.672-28-6.00146
-1.2-11 0.0
-6.00146
-1.12-110.246
-6.00146
0.246
0.246
-6.00146
0.246
1.735-28-6.30154
-1.26-110.0
-6.30154
-1.18-110.246
-6.30154
0.246
0.246
-6.30154
0.246
1.83-28 -6.60161
-1.32-110.0
-6.60161
-1.23-110.246
-6.60161
0.246
0.246
-6.60161
0.246
1.893-28-6.90168
-1.38-110.0
-6.90168
-1.29-110.246
-6.90168
0.246
0.246
-6.90168
0.246
1.956-28-7.20176
-1.44-110.0
-7.20176
-1.35-110.246
-7.20176
0.246
0.246
-7.20176
0.246
2.019-28-7.50183
-1.5-11 0.0
-7.50183
-1.4-11 0.246
-7.50183
0.246
0.246
-7.50183
0.246
2.083-28-7.8019
-1.55-110.0
-7.8019
-1.46-110.246
-7.8019
0.246
0.246
-7.8019
0.246
2.146-28-8.10198
-1.61-110.0
-8.10198
-1.51-110.246
-8.10198
0.246
0.246
-8.10198
0.246
2.209-28-8.40205
-1.67-110.0
-8.40205
-1.57-110.246
-8.40205
0.246
0.246
-8.40205
0.246
2.272-28-8.70212
-1.73-110.0
-8.70212
-1.63-110.246
-8.70212
0.246
0.246
-8.70212
0.246
2.335-28-9.0022
-1.79-110.0
-9.0022
-1.68-110.246
-9.0022
0.246
0.246
-9.0022
0.246
2.398-28-9.30227
-1.85-110.0
-9.30227
-1.74-110.246
-9.30227
0.246
0.246
-9.30227
0.246
2.461-28-9.60234
-1.91-110.0
-9.60234
-1.79-110.246
-9.60234
0.246
0.246
-9.60234
0.246
2.524-28-9.90241
-1.97-110.0
-9.90241
-1.85-110.246
-9.90241

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1398 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553

Altair Engineering

0.246
0.246
-9.90241
0.246
2.556-28-10.2025
-2.03-110.0
-10.2025
-1.91-110.246
-10.2025
0.246
0.246
-10.2025
0.246
2.619-28-10.5026
-2.09-110.0
-10.5026
-1.96-110.246
-10.5026
0.246
0.246
-10.5026
0.246
2.682-28-10.8026
-2.15-110.0
-10.8026
-2.02-110.246
-10.8026
0.246
0.246
-10.8026
0.246
2.745-28-11.1027
-2.21-110.0
-11.1027
-2.07-110.246
-11.1027
0.246
0.246
-11.1027
0.246
2.777-28-11.4028
-2.27-110.0
-11.4028
-2.13-110.246
-11.4028
0.246
0.246
-11.4028
0.246
2.84-28 -11.7029
-2.33-110.0
-11.7029
-2.19-110.246
-11.7029
0.246
0.246
-11.7029
0.246
2.871-28-12.0029
-2.39-110.0
-12.0029
-2.24-110.246
-12.0029
0.246
0.246
-12.0029
0.246
2.935-28-12.303
-2.45-110.0
-12.303
-2.3-11 0.246
-12.303
0.246
0.246
-12.303
0.246
2.966-28-12.6031
-2.51-110.0
-12.6031
-2.35-110.246
-12.6031
0.246
0.246
-12.6031
0.246
2.935-28-12.903
-7.36-110.0
-12.903
-6.9-11 0.246
-12.903
0.246
0.246
-12.903
0.246
2.903-28-13.2031
-7.42-110.0
-13.2031
-6.95-110.246
-13.2031
0.246
0.246
-13.2031
0.246
2.84-28 -13.5032
-7.48-110.0
-13.5032
-7.01-110.246
-13.5032
0.246
0.246
-13.5032
0.246
2.777-28-13.8032
-7.54-110.0
-13.8032
-7.06-110.246
-13.8032
0.246
0.246
-13.8032
0.246
2.745-28-14.1033
-7.6-11 0.0
-14.1033
-7.12-110.246
-14.1033
0.246
0.246
-14.1033
0.246
2.682-28-14.4034
-7.67-110.0
-14.4034
-7.19-110.246
-14.4034
0.246
0.246
-14.4034
0.246
2.619-28-14.7034
-7.73-110.0
-14.7034
-7.24-110.246
-14.7034
0.246
0.246
-14.7034
0.246
2.587-28-15.0035
-7.78-110.0
-15.0035
-7.3-11 0.246
-15.0035
0.246
0.246
-15.0035

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1399


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622

0.246
2.524-28-15.3036
-7.84-110.0
-15.3036
-7.35-110.246
-15.3036
0.246
0.246
-15.3036
0.246
2.461-28-15.6037
-7.9-11 0.0
-15.6037
-7.41-110.246
-15.6037
0.246
0.246
-15.6037
0.246
2.398-28-15.9037
-7.96-110.0
-15.9037
-7.47-110.246
-15.9037
0.246
0.246
-15.9037
0.246
2.335-28-16.2038
-8.02-110.0
-16.2038
-7.52-110.246
-16.2038
0.246
0.246
-16.2038
0.246
2.272-28-16.5039
-8.08-110.0
-16.5039
-7.58-110.246
-16.5039
0.246
0.246
-16.5039
0.246
2.209-28-16.804
-8.14-110.0
-16.804
-7.63-110.246
-16.804
0.246
0.246
-16.804
0.246
2.146-28-17.104
-8.2-11 0.0
-17.104
-7.69-110.246
-17.104
0.246
0.246
-17.104
0.246
2.083-28-17.4041
-8.26-110.0
-17.4041
-7.75-110.246
-17.4041
0.246
0.246
-17.4041
0.246
2.019-28-17.7042
-8.32-110.0
-17.7042
-7.8-11 0.246
-17.7042
0.246
0.246
-17.7042
0.246
1.956-28-18.0042
-8.38-110.0
-18.0042
-7.86-110.246
-18.0042
0.246
0.246
-18.0042
0.246
1.893-28-18.3043
-8.44-110.0
-18.3043
-7.91-110.246
-18.3043
0.246
0.246
-18.3043
0.246
1.83-28 -18.6044
-8.5-11 0.0
-18.6044
-7.97-110.246
-18.6044
0.246
0.246
-18.6044
0.246
1.735-28-18.9045
-8.56-110.0
-18.9045
-8.03-110.246
-18.9045
0.246
0.246
-18.9045
0.246
1.672-28-19.2045
-8.62-110.0
-19.2045
-8.08-110.246
-19.2045
0.246
0.246
-19.2045
0.246
1.609-28-19.5046
-8.68-110.0
-19.5046
-8.14-110.246
-19.5046
0.246
0.246
-19.5046
0.246
1.515-28-19.8047
-8.74-110.0
-19.8047
-8.19-110.246
-19.8047
0.246
0.246
-19.8047
0.246
1.452-28-20.1048
-8.8-11 0.0
-20.1048
-8.25-110.246
-20.1048
0.246
0.246
-20.1048
0.246
1.388-28-20.4048

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1400 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691

Altair Engineering

-8.86-110.0
-20.4048
-8.31-110.246
-20.4048
0.246
0.246
-20.4048
0.246
1.294-28-20.7049
-8.92-110.0
-20.7049
-8.36-110.246
-20.7049
0.246
0.246
-20.7049
0.246
1.231-28-21.005
-8.98-110.0
-21.005
-8.42-110.246
-21.005
0.246
0.246
-21.005
0.246
1.136-28-21.3051
-9.04-110.0
-21.3051
-8.47-110.246
-21.3051
0.246
0.246
-21.3051
0.246
1.073-28-21.6051
-9.1-11 0.0
-21.6051
-8.53-110.246
-21.6051
0.246
0.246
-21.6051
0.246
9.782-29-21.9052
-9.16-110.0
-21.9052
-8.59-110.246
-21.9052
0.246
0.246
-21.9052
0.246
8.835-29-22.2053
-9.22-110.0
-22.2053
-8.64-110.246
-22.2053
0.246
0.246
-22.2053
0.246
8.204-29-22.5053
-9.28-110.0
-22.5053
-8.7-11 0.246
-22.5053
0.246
0.246
-22.5053
0.246
7.258-29-22.8054
-9.34-110.0
-22.8054
-8.75-110.246
-22.8054
0.246
0.246
-22.8054
0.246
6.311-29-23.1055
-9.4-11 0.0
-23.1055
-8.81-110.246
-23.1055
0.246
0.246
-23.1055
0.246
5.364-29-23.4056
-9.46-110.0
-23.4056
-8.87-110.246
-23.4056
0.246
0.246
-23.4056
0.246
4.733-29-23.7056
-9.52-110.0
-23.7056
-8.92-110.246
-23.7056
0.246
0.246
-23.7056
0.246
3.787-29-24.0057
-9.58-110.0
-24.0057
-8.98-110.246
-24.0057
0.246
0.246
-24.0057
0.246
2.84-29 -24.3058
-9.64-110.0
-24.3058
-9.04-110.246
-24.3058
0.246
0.246
-24.3058
0.246
1.893-29-24.6059
-9.7-11 0.0
-24.6059
-9.09-110.246
-24.6059
0.246
0.246
-24.6059
0.246
9.466-30-24.9059
-9.76-110.0
-24.9059
-9.15-110.246
-24.9059
0.246
0.246
-24.9059
0.246
4.151-12-25.206
-9.82-112.767-12-25.206
-9.16-110.246
-25.206
0.246
0.246
-25.206
0.492
4.323-13-.300073
0.492
0.246
-.300073

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1401


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

1.621-13-.600146
0.246
-.600146
1.592-13-0.90022
0.246
-0.90022
2.009-13-1.20029
0.246
-1.20029
2.5-13 -1.50037
0.246
-1.50037
3.004-13-1.80044
0.246
-1.80044
3.51-13 -2.10051
0.246
-2.10051
4.016-13-2.40059
0.246
-2.40059
4.522-13-2.70066
0.246
-2.70066
5.028-13-3.00073
0.246
-3.00073
5.534-13-3.30081
0.246
-3.30081
6.041-13-3.60088
0.246
-3.60088
6.547-13-3.90095
0.246
-3.90095
7.053-13-4.20102
0.246
-4.20102
7.559-13-4.5011
0.246
-4.5011
8.066-13-4.80117
0.246
-4.80117
8.572-13-5.10124
0.246
-5.10124
9.078-13-5.40132
0.246
-5.40132
9.584-13-5.70139
0.246
-5.70139
1.009-12-6.00146
0.246
-6.00146
1.06-12 -6.30154
0.246
-6.30154
1.11-12 -6.60161
0.246
-6.60161
1.161-12-6.90168
0.246
-6.90168
1.212-12-7.20176
0.246
-7.20176
1.262-12-7.50183
0.246
-7.50183
1.313-12-7.8019
0.246
-7.8019
1.363-12-8.10198
0.246
-8.10198
1.414-12-8.40205
0.246
-8.40205
1.465-12-8.70212
0.246
-8.70212
1.515-12-9.0022
0.246
-9.0022
1.566-12-9.30227
0.246
-9.30227
1.616-12-9.60234
0.246
-9.60234
1.667-12-9.90242
0.246
-9.90242
1.718-12-10.2025
0.246
-10.2025
1.768-12-10.5026
0.246
-10.5026
1.819-12-10.8026

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1402 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

761
762
763
764
765
766
767
768
769
770
771
772
773
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989

Altair Engineering

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

0.246
-10.8026
1.87-12 -11.1027
0.246
-11.1027
1.92-12 -11.4028
0.246
-11.4028
1.971-12-11.7029
0.246
-11.7029
2.021-12-12.0029
0.246
-12.0029
2.072-12-12.303
0.246
-12.303
2.123-12-12.6031
0.246
-12.6031
6.223-12-12.903
0.246
-12.903
6.274-12-13.2031
0.246
-13.2031
6.324-12-13.5032
0.246
-13.5032
6.375-12-13.8032
0.246
-13.8032
6.425-12-14.1033
0.246
-14.1033
6.476-12-14.4034
0.246
-14.4034
6.527-12-14.7034
0.246
-14.7034
6.577-12-15.0035
0.246
-15.0035
6.628-12-15.3036
0.246
-15.3036
6.679-12-15.6037
0.246
-15.6037
6.729-12-15.9037
0.246
-15.9037
6.78-12 -16.2038
0.246
-16.2038
6.83-12 -16.5039
0.246
-16.5039
6.881-12-16.804
0.246
-16.804
6.932-12-17.104
0.246
-17.104
6.982-12-17.4041
0.246
-17.4041
7.033-12-17.7042
0.246
-17.7042
7.083-12-18.0042
0.246
-18.0042
7.134-12-18.3043
0.246
-18.3043
7.185-12-18.6044
0.246
-18.6044
7.235-12-18.9045
0.246
-18.9045
7.286-12-19.2045
0.246
-19.2045
7.337-12-19.5046
0.246
-19.5046
7.387-12-19.8047
0.246
-19.8047
7.438-12-20.1048
0.246
-20.1048
7.488-12-20.4048
0.246
-20.4048
7.539-12-20.7049
0.246
-20.7049
7.59-12 -21.005
0.246
-21.005

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1403


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058

0.492
7.64-12 -21.3051
0.492
0.246
-21.3051
0.492
7.691-12-21.6051
0.492
0.246
-21.6051
0.492
7.742-12-21.9052
0.492
0.246
-21.9052
0.492
7.792-12-22.2053
0.492
0.246
-22.2053
0.492
7.843-12-22.5053
0.492
0.246
-22.5053
0.492
7.893-12-22.8054
0.492
0.246
-22.8054
0.492
7.944-12-23.1055
0.492
0.246
-23.1055
0.492
7.995-12-23.4056
0.492
0.246
-23.4056
0.492
8.045-12-23.7056
0.492
0.246
-23.7056
0.492
8.096-12-24.0057
0.492
0.246
-24.0057
0.492
8.146-12-24.3058
0.492
0.246
-24.3058
0.492
8.197-12-24.6059
0.492
0.246
-24.6059
0.492
8.248-12-24.9059
0.492
0.246
-24.9059
0.492
5.534-12-25.206
0.492
0.246
-25.206
-5.24-130.492
-.300073
0.246
0.492
-.300073
-1.05-120.492
-.600146
0.246
0.492
-.600146
-1.57-120.492
-.900219
0.246
0.492
-0.90022
-2.09-120.492
-1.20029
0.246
0.492
-1.20029
-2.63-120.492
-1.50037
0.246
0.492
-1.50037
-3.15-120.492
-1.80044
0.246
0.492
-1.80044
-3.67-120.492
-2.10051
0.246
0.492
-2.10051
-4.19-120.492
-2.40059
0.246
0.492
-2.40059
-4.72-120.492
-2.70066
0.246
0.492
-2.70066
-5.24-120.492
-3.00073
0.246
0.492
-3.00073
-5.76-120.492
-3.30081
0.246
0.492
-3.30081
-6.29-120.492
-3.60088
0.246
0.492
-3.60088
-6.81-120.492
-3.90095
0.246
0.492
-3.90095
-7.33-120.492
-4.20102
0.246
0.492
-4.20102
-7.87-120.492
-4.5011
0.246
0.492
-4.5011
-8.39-120.492
-4.80117
0.246
0.492
-4.80117
-8.91-120.492
-5.10124
0.246
0.492
-5.10124
-9.44-120.492
-5.40132
0.246
0.492
-5.40132
-9.96-120.492
-5.70139
0.246
0.492
-5.70139
-1.05-110.492
-6.00146
0.246
0.492
-6.00146
-1.1-11 0.492
-6.30154

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1404 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287

Altair Engineering

0.246
0.492
-1.15-110.492
0.246
0.492
-1.2-11 0.492
0.246
0.492
-1.26-110.492
0.246
0.492
-1.31-110.492
0.246
0.492
-1.36-110.492
0.246
0.492
-1.41-110.492
0.246
0.492
-1.46-110.492
0.246
0.492
-1.52-110.492
0.246
0.492
-1.57-110.492
0.246
0.492
-1.62-110.492
0.246
0.492
-1.67-110.492
0.246
0.492
-1.73-110.492
0.246
0.492
-1.78-110.492
0.246
0.492
-1.83-110.492
0.246
0.492
-1.88-110.492
0.246
0.492
-1.94-110.492
0.246
0.492
-1.99-110.492
0.246
0.492
-2.04-110.492
0.246
0.492
-2.09-110.492
0.246
0.492
-2.14-110.492
0.246
0.492
-2.2-11 0.492
0.246
0.492
-6.43-110.492
0.246
0.492
-6.49-110.492
0.246
0.492
-6.54-110.492
0.246
0.492
-6.59-110.492
0.246
0.492
-6.64-110.492
0.246
0.492
-6.71-110.492
0.246
0.492
-6.76-110.492
0.246
0.492
-6.81-110.492
0.246
0.492
-6.86-110.492
0.246
0.492
-6.91-110.492
0.246
0.492
-6.97-110.492
0.246
0.492
-7.02-110.492
0.246
0.492
-7.07-110.492
0.246
0.492

-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1405


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356

-7.12-110.492
0.246
0.492
-7.18-110.492
0.246
0.492
-7.23-110.492
0.246
0.492
-7.28-110.492
0.246
0.492
-7.33-110.492
0.246
0.492
-7.39-110.492
0.246
0.492
-7.44-110.492
0.246
0.492
-7.49-110.492
0.246
0.492
-7.54-110.492
0.246
0.492
-7.59-110.492
0.246
0.492
-7.65-110.492
0.246
0.492
-7.7-11 0.492
0.246
0.492
-7.75-110.492
0.246
0.492
-7.8-11 0.492
0.246
0.492
-7.86-110.492
0.246
0.492
-7.91-110.492
0.246
0.492
-7.96-110.492
0.246
0.492
-8.01-110.492
0.246
0.492
-8.07-110.492
0.246
0.492
-8.12-110.492
0.246
0.492
-8.17-110.492
0.246
0.492
-8.22-110.492
0.246
0.492
-8.27-110.492
0.246
0.492
-8.33-110.492
0.246
0.492
-8.38-110.492
0.246
0.492
-8.43-110.492
0.246
0.492
-8.48-110.492
0.246
0.492
-8.54-110.492
0.246
0.492
-8.59-110.492
0.246
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.600146
-0.90022
-1.20029
-1.50037
-1.80044
-2.10051
-2.40059
-2.70066
-3.00073
-3.30081

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1406 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505

Altair Engineering

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-3.60088
-3.90095
-4.20102
-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.0022
-9.30227
-9.60234
-9.90242
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028
-11.7029
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5032
-13.8032
-14.1033
-14.4034
-14.7034
-15.0035
-15.3036
-15.6037
-15.9037
-16.2038
-16.5039
-16.804
-17.104
-17.4041
-17.7042
-18.0042
-18.3043
-18.6044
-18.9045
-19.2045
-19.5046
-19.8047
-20.1048
-20.4048
-20.7049
-21.005
-21.3051
-21.6051
-21.9052
-22.2053
-22.5053
-22.8054
-23.1055
-23.4056
-23.7056
-24.0057

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1407


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574

0.492
0.492
0.492
0.492
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246

0.492
-24.3058
0.492
-24.6059
0.492
-24.9059
0.492
-25.206
0.0
-.300073
8.522-26-.300073
0.246
-.300073
0.246
-.300073
0.0
-.600146
1.441-26-.600146
0.246
-.600146
0.246
-.600146
0.0
-.900219
2.685-27-.900219
0.246
-.900219
0.246
-.900219
0.0
-1.20029
8.709-28-1.20029
0.246
-1.20029
0.246
-1.20029
0.0
-1.50037
6.595-28-1.50037
0.246
-1.50037
0.246
-1.50037
0.0
-1.80044
7.258-28-1.80044
0.246
-1.80044
0.246
-1.80044
0.0
-2.10051
7.936-28-2.10051
0.246
-2.10051
0.246
-2.10051
0.0
-2.40058
8.993-28-2.40058
0.246
-2.40058
0.246
-2.40058
0.0
-2.70066
1.01-27 -2.70066
0.246
-2.70066
0.246
-2.70066
0.0
-3.00073
1.185-27-3.00073
0.246
-3.00073
0.246
-3.00073
0.0
-3.3008
1.313-27-3.3008
0.246
-3.3008
0.246
-3.3008
0.0
-3.60088
1.341-27-3.60088
0.246
-3.60088
0.246
-3.60088
0.0
-3.90095
1.36-27 -3.90095
0.246
-3.90095
0.246
-3.90095
0.0
-4.20102
1.447-27-4.20102
0.246
-4.20102
0.246
-4.20102
0.0
-4.5011
1.549-27-4.5011
0.246
-4.5011
0.246
-4.5011
0.0
-4.80117
1.775-27-4.80117
0.246
-4.80117
0.246
-4.80117
0.0
-5.10124

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1408 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643

Altair Engineering

-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492

1.907-27-5.10124
0.246
-5.10124
0.246
-5.10124
0.0
-5.40132
2.023-27-5.40132
0.246
-5.40132
0.246
-5.40132
0.0
-5.70139
2.136-27-5.70139
0.246
-5.70139
0.246
-5.70139
0.0
-6.00146
2.248-27-6.00146
0.246
-6.00146
0.246
-6.00146
0.0
-6.30154
2.36-27 -6.30154
0.246
-6.30154
0.246
-6.30154
0.0
-6.60161
2.474-27-6.60161
0.246
-6.60161
0.246
-6.60161
0.0
-6.90168
2.551-27-6.90168
0.246
-6.90168
0.246
-6.90168
0.0
-7.20176
2.693-27-7.20176
0.246
-7.20176
0.246
-7.20176
0.0
-7.50183
2.965-27-7.50183
0.246
-7.50183
0.246
-7.50183
0.0
-7.8019
3.113-27-7.8019
0.246
-7.8019
0.246
-7.8019
0.0
-8.10198
3.067-27-8.10198
0.246
-8.10198
0.246
-8.10198
0.0
-8.40205
2.979-27-8.40205
0.246
-8.40205
0.246
-8.40205
0.0
-8.70212
3.233-27-8.70212
0.246
-8.70212
0.246
-8.70212
0.0
-9.0022
3.323-27-9.00219
0.246
-9.00219
0.246
-9.0022
0.0
-9.30227
3.67-27 -9.30227
0.246
-9.30227
0.246
-9.30227
0.0
-9.60234
3.58-27 -9.60234
0.246
-9.60234
0.246
-9.60234
0.0
-9.90241
3.454-27-9.90241
0.246
-9.90241
0.246
-9.90241
0.0
-10.2025
3.782-27-10.2025

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1409


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032

-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492

0.246
-10.2025
0.246
-10.2025
0.0
-10.5026
3.659-27-10.5026
0.246
-10.5026
0.246
-10.5026
0.0
-10.8026
4.003-27-10.8026
0.246
-10.8026
0.246
-10.8026
0.0
-11.1027
4.154-27-11.1027
0.246
-11.1027
0.246
-11.1027
0.0
-11.4028
4.274-27-11.4028
0.246
-11.4028
0.246
-11.4028
0.0
-11.7029
4.388-27-11.7028
0.246
-11.7028
0.246
-11.7029
0.0
-12.0029
4.5-27 -12.0029
0.246
-12.0029
0.246
-12.0029
0.0
-12.303
4.358-27-12.303
0.246
-12.303
0.246
-12.303
0.0
-12.6031
4.424-27-12.6031
0.246
-12.6031
0.246
-12.6031
0.0
-12.903
1.381-26-12.903
0.246
-12.903
0.246
-12.903
0.0
-13.2031
1.395-26-13.2031
0.246
-13.2031
0.246
-13.2031
0.0
-13.5032
1.407-26-13.5031
0.246
-13.5031
0.246
-13.5032
0.0
-13.8032
1.418-26-13.8032
0.246
-13.8032
0.246
-13.8032
0.0
-14.1033
1.429-26-14.1033
0.246
-14.1033
0.246
-14.1033
0.0
-14.4034
1.441-26-14.4034
0.246
-14.4034
0.246
-14.4034
0.0
-14.7034
1.452-26-14.7034
0.246
-14.7034
0.246
-14.7034
0.0
-15.0035
1.463-26-15.0035
0.246
-15.0035
0.246
-15.0035
0.0
-15.3036
1.454-26-15.3036
0.246
-15.3036

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1410 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101

Altair Engineering

-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246

0.246
-15.3036
0.0
-15.6037
1.38-26 -15.6037
0.246
-15.6037
0.246
-15.6037
0.0
-15.9037
1.479-26-15.9037
0.246
-15.9037
0.246
-15.9037
0.0
-16.2038
1.505-26-16.2038
0.246
-16.2038
0.246
-16.2038
0.0
-16.5039
1.519-26-16.5039
0.246
-16.5039
0.246
-16.5039
0.0
-16.804
1.531-26-16.804
0.246
-16.804
0.246
-16.804
0.0
-17.104
1.542-26-17.104
0.246
-17.104
0.246
-17.104
0.0
-17.4041
1.553-26-17.4041
0.246
-17.4041
0.246
-17.4041
0.0
-17.7042
1.564-26-17.7042
0.246
-17.7042
0.246
-17.7042
0.0
-18.0042
1.576-26-18.0042
0.246
-18.0042
0.246
-18.0042
0.0
-18.3043
1.477-26-18.3043
0.246
-18.3043
0.246
-18.3043
0.0
-18.6044
1.58-26 -18.6044
0.246
-18.6044
0.246
-18.6044
0.0
-18.9045
1.606-26-18.9045
0.246
-18.9045
0.246
-18.9045
0.0
-19.2045
1.62-26 -19.2045
0.246
-19.2045
0.246
-19.2045
0.0
-19.5046
1.632-26-19.5046
0.246
-19.5046
0.246
-19.5046
0.0
-19.8047
1.643-26-19.8047
0.246
-19.8047
0.246
-19.8047
0.0
-20.1048
1.655-26-20.1048
0.246
-20.1048
0.246
-20.1048
0.0
-20.4048
1.666-26-20.4048
0.246
-20.4048
0.246
-20.4048

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1411


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170

-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.246
-0.492
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492

0.0
-20.7049
1.677-26-20.7049
0.246
-20.7049
0.246
-20.7049
0.0
-21.005
1.572-26-21.005
0.246
-21.005
0.246
-21.005
0.0
-21.3051
1.68-26 -21.3051
0.246
-21.3051
0.246
-21.3051
0.0
-21.6051
1.708-26-21.6051
0.246
-21.6051
0.246
-21.6051
0.0
-21.9052
1.722-26-21.9052
0.246
-21.9052
0.246
-21.9052
0.0
-22.2053
1.733-26-22.2053
0.246
-22.2053
0.246
-22.2053
0.0
-22.5053
1.745-26-22.5053
0.246
-22.5053
0.246
-22.5053
0.0
-22.8054
1.756-26-22.8054
0.246
-22.8054
0.246
-22.8054
0.0
-23.1055
1.767-26-23.1055
0.246
-23.1055
0.246
-23.1055
0.0
-23.4056
1.778-26-23.4056
0.246
-23.4056
0.246
-23.4056
0.0
-23.7056
1.666-26-23.7056
0.246
-23.7056
0.246
-23.7056
0.0
-24.0057
1.78-26 -24.0057
0.246
-24.0057
0.246
-24.0057
0.0
-24.3058
1.809-26-24.3058
0.246
-24.3058
0.246
-24.3058
0.0
-24.6059
1.823-26-24.6059
0.246
-24.6059
0.246
-24.6059
0.0
-24.9059
1.835-26-24.9059
0.246
-24.9059
0.246
-24.9059
1.384-12-25.206
1.272-26-25.206
0.246
-25.206
0.246
-25.206
0.492
-.300073
0.492
-.300073
0.492
-.600146
0.492
-.600146
0.492
-.900219

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1412 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239

Altair Engineering

-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-.900219
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40058
-2.40058
-2.70066
-2.70066
-3.00073
-3.00073
-3.3008
-3.3008
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.00219
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1413


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468

-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492
-0.246
-0.492

0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492
0.492

-11.4028
-11.4028
-11.7028
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5031
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1414 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537

Altair Engineering

-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.492 0.492
-0.246 0.492
-0.246 -0.246
-5.62-13-0.246
-0.246 -0.246
-1.12-12-0.246
-0.246 -0.246
-1.68-12-0.246
-0.246 -0.246
-2.24-12-0.246
-0.246 -0.246
-2.81-12-0.246
-0.246 -0.246
-3.37-12-0.246
-0.246 -0.246
-3.93-12-0.246
-0.246 -0.246
-4.49-12-0.246
-0.246 -0.246
-5.06-12-0.246
-0.246 -0.246
-5.62-12-0.246
-0.246 -0.246
-6.18-12-0.246
-0.246 -0.246
-6.74-12-0.246
-0.246 -0.246
-7.3-12 -0.246
-0.246 -0.246
-7.86-12-0.246
-0.246 -0.246
-8.43-12-0.246
-0.246 -0.246
-8.99-12-0.246
-0.246 -0.246
-9.55-12-0.246
-0.246 -0.246
-1.01-11-0.246
-0.246 -0.246
-1.07-11-0.246
-0.246 -0.246
-1.12-11-0.246
-0.246 -0.246
-1.18-11-0.246
-0.246 -0.246
-1.23-11-0.246

-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.300073
-.600146
-.600146
-.900219
-.900219
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40058
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.3008
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1415


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766

-0.246 -0.246
-1.29-11-0.246
-0.246 -0.246
-1.35-11-0.246
-0.246 -0.246
-1.4-11 -0.246
-0.246 -0.246
-1.46-11-0.246
-0.246 -0.246
-1.51-11-0.246
-0.246 -0.246
-1.57-11-0.246
-0.246 -0.246
-1.63-11-0.246
-0.246 -0.246
-1.68-11-0.246
-0.246 -0.246
-1.74-11-0.246
-0.246 -0.246
-1.79-11-0.246
-0.246 -0.246
-1.85-11-0.246
-0.246 -0.246
-1.91-11-0.246
-0.246 -0.246
-1.96-11-0.246
-0.246 -0.246
-2.02-11-0.246
-0.246 -0.246
-2.07-11-0.246
-0.246 -0.246
-2.13-11-0.246
-0.246 -0.246
-2.19-11-0.246
-0.246 -0.246
-2.24-11-0.246
-0.246 -0.246
-2.3-11 -0.246
-0.246 -0.246
-2.35-11-0.246
-0.246 -0.246
-6.9-11 -0.246
-0.246 -0.246
-6.95-11-0.246
-0.246 -0.246
-7.01-11-0.246
-0.246 -0.246
-7.06-11-0.246
-0.246 -0.246
-7.12-11-0.246
-0.246 -0.246
-7.19-11-0.246
-0.246 -0.246
-7.24-11-0.246
-0.246 -0.246
-7.3-11 -0.246
-0.246 -0.246
-7.35-11-0.246
-0.246 -0.246
-7.41-11-0.246
-0.246 -0.246
-7.47-11-0.246
-0.246 -0.246
-7.52-11-0.246
-0.246 -0.246
-7.58-11-0.246
-0.246 -0.246
-7.63-11-0.246
-0.246 -0.246

-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1416 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835

Altair Engineering

-7.69-11-0.246
-0.246 -0.246
-7.75-11-0.246
-0.246 -0.246
-7.8-11 -0.246
-0.246 -0.246
-7.86-11-0.246
-0.246 -0.246
-7.91-11-0.246
-0.246 -0.246
-7.97-11-0.246
-0.246 -0.246
-8.03-11-0.246
-0.246 -0.246
-8.08-11-0.246
-0.246 -0.246
-8.14-11-0.246
-0.246 -0.246
-8.19-11-0.246
-0.246 -0.246
-8.25-11-0.246
-0.246 -0.246
-8.31-11-0.246
-0.246 -0.246
-8.36-11-0.246
-0.246 -0.246
-8.42-11-0.246
-0.246 -0.246
-8.47-11-0.246
-0.246 -0.246
-8.53-11-0.246
-0.246 -0.246
-8.59-11-0.246
-0.246 -0.246
-8.64-11-0.246
-0.246 -0.246
-8.7-11 -0.246
-0.246 -0.246
-8.75-11-0.246
-0.246 -0.246
-8.81-11-0.246
-0.246 -0.246
-8.87-11-0.246
-0.246 -0.246
-8.92-11-0.246
-0.246 -0.246
-8.98-11-0.246
-0.246 -0.246
-9.04-11-0.246
-0.246 -0.246
-9.09-11-0.246
-0.246 -0.246
-9.15-11-0.246
-0.246 -0.246
-9.16-11-0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246
-0.492 -0.246

-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300074
-.600146
-.900219
-1.20029
-1.50037
-1.80044
-2.10051
-2.40058
-2.70066
-3.00073
-3.3008
-3.60088
-3.90095
-4.20102

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1417


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.00219
-9.30227
-9.60234
-9.90241
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028
-11.7028
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5031
-13.8032
-14.1033
-14.4034
-14.7034
-15.0035
-15.3036
-15.6037
-15.9037
-16.2038
-16.5039
-16.804
-17.104
-17.4041
-17.7042
-18.0042
-18.3043
-18.6044
-18.9045
-19.2045
-19.5046
-19.8047
-20.1048
-20.4048
-20.7049
-21.005
-21.3051
-21.6051
-21.9052
-22.2053
-22.5053
-22.8054
-23.1055
-23.4056
-23.7056
-24.0057
-24.3058
-24.6059
-24.9059

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1418 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053

Altair Engineering

-0.492 -0.246
-0.246 -0.492
-5.24-13-0.492
-0.246 -0.492
-1.05-12-0.492
-0.246 -0.492
-1.57-12-0.492
-0.246 -0.492
-2.09-12-0.492
-0.246 -0.492
-2.63-12-0.492
-0.246 -0.492
-3.15-12-0.492
-0.246 -0.492
-3.67-12-0.492
-0.246 -0.492
-4.19-12-0.492
-0.246 -0.492
-4.72-12-0.492
-0.246 -0.492
-5.24-12-0.492
-0.246 -0.492
-5.76-12-0.492
-0.246 -0.492
-6.29-12-0.492
-0.246 -0.492
-6.81-12-0.492
-0.246 -0.492
-7.33-12-0.492
-0.246 -0.492
-7.87-12-0.492
-0.246 -0.492
-8.39-12-0.492
-0.246 -0.492
-8.91-12-0.492
-0.246 -0.492
-9.44-12-0.492
-0.246 -0.492
-9.96-12-0.492
-0.246 -0.492
-1.05-11-0.492
-0.246 -0.492
-1.1-11 -0.492
-0.246 -0.492
-1.15-11-0.492
-0.246 -0.492
-1.2-11 -0.492
-0.246 -0.492
-1.26-11-0.492
-0.246 -0.492
-1.31-11-0.492
-0.246 -0.492
-1.36-11-0.492
-0.246 -0.492
-1.41-11-0.492
-0.246 -0.492
-1.46-11-0.492
-0.246 -0.492
-1.52-11-0.492
-0.246 -0.492
-1.57-11-0.492
-0.246 -0.492
-1.62-11-0.492
-0.246 -0.492
-1.67-11-0.492
-0.246 -0.492
-1.73-11-0.492
-0.246 -0.492
-1.78-11-0.492

-25.206
-.300073
-.300073
-.600146
-.600146
-.900219
-.900219
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40058
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.3008
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90241
-10.2025
-10.2025

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1419


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282

-0.246 -0.492
-1.83-11-0.492
-0.246 -0.492
-1.88-11-0.492
-0.246 -0.492
-1.94-11-0.492
-0.246 -0.492
-1.99-11-0.492
-0.246 -0.492
-2.04-11-0.492
-0.246 -0.492
-2.09-11-0.492
-0.246 -0.492
-2.14-11-0.492
-0.246 -0.492
-2.2-11 -0.492
-0.246 -0.492
-6.43-11-0.492
-0.246 -0.492
-6.49-11-0.492
-0.246 -0.492
-6.54-11-0.492
-0.246 -0.492
-6.59-11-0.492
-0.246 -0.492
-6.64-11-0.492
-0.246 -0.492
-6.71-11-0.492
-0.246 -0.492
-6.76-11-0.492
-0.246 -0.492
-6.81-11-0.492
-0.246 -0.492
-6.86-11-0.492
-0.246 -0.492
-6.91-11-0.492
-0.246 -0.492
-6.97-11-0.492
-0.246 -0.492
-7.02-11-0.492
-0.246 -0.492
-7.07-11-0.492
-0.246 -0.492
-7.12-11-0.492
-0.246 -0.492
-7.18-11-0.492
-0.246 -0.492
-7.23-11-0.492
-0.246 -0.492
-7.28-11-0.492
-0.246 -0.492
-7.33-11-0.492
-0.246 -0.492
-7.39-11-0.492
-0.246 -0.492
-7.44-11-0.492
-0.246 -0.492
-7.49-11-0.492
-0.246 -0.492
-7.54-11-0.492
-0.246 -0.492
-7.59-11-0.492
-0.246 -0.492
-7.65-11-0.492
-0.246 -0.492
-7.7-11 -0.492
-0.246 -0.492
-7.75-11-0.492
-0.246 -0.492

-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1420 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351

Altair Engineering

-7.8-11 -0.492
-0.246 -0.492
-7.86-11-0.492
-0.246 -0.492
-7.91-11-0.492
-0.246 -0.492
-7.96-11-0.492
-0.246 -0.492
-8.01-11-0.492
-0.246 -0.492
-8.07-11-0.492
-0.246 -0.492
-8.12-11-0.492
-0.246 -0.492
-8.17-11-0.492
-0.246 -0.492
-8.22-11-0.492
-0.246 -0.492
-8.27-11-0.492
-0.246 -0.492
-8.33-11-0.492
-0.246 -0.492
-8.38-11-0.492
-0.246 -0.492
-8.43-11-0.492
-0.246 -0.492
-8.48-11-0.492
-0.246 -0.492
-8.54-11-0.492
-0.246 -0.492
-8.59-11-0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492
-0.492 -0.492

-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.600146
-.900219
-1.20029
-1.50037
-1.80044
-2.10051
-2.40058
-2.70066
-3.00073
-3.3008
-3.60088
-3.90095
-4.20102
-4.5011
-4.80117
-5.10124
-5.40132
-5.70139
-6.00146
-6.30154
-6.60161
-6.90168
-7.20176
-7.50183
-7.8019
-8.10198
-8.40205
-8.70212
-9.00219
-9.30227
-9.60234
-9.90241
-10.2025
-10.5026
-10.8026
-11.1027
-11.4028

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1421


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3352
3353
3354
3355
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-11.7028
-12.0029
-12.303
-12.6031
-12.903
-13.2031
-13.5031
-13.8032
-14.1033
-14.4034
-14.7034
-15.0035
-15.3036
-15.6037
-15.9037
-16.2038
-16.5039
-16.804
-17.104
-17.4041
-17.7042
-18.0042
-18.3043
-18.6044
-18.9045
-19.2045
-19.5046
-19.8047
-20.1048
-20.4048
-20.7049
-21.005
-21.3051
-21.6051
-21.9052
-22.2053
-22.5053
-22.8054
-23.1055
-23.4056
-23.7056
-24.0057
-24.3058
-24.6059
-24.9059
-25.206
-.300073
-.300074
-.600146
-.600146
-0.90022
-0.90022
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40059
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.30081
-3.30081
-3.60088

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1422 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3722
3723
3724
3725
3726
3727
3728
3729

Altair Engineering

0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227
-9.60234
-9.60234
-9.90241
-9.90242
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1423


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798

0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246

-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047
-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1424 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867

Altair Engineering

0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492

-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.246
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
-.300073
-.300074
-.600146
-.600146
-0.90022
-0.90022
-1.20029
-1.20029
-1.50037
-1.50037
-1.80044
-1.80044
-2.10051
-2.10051
-2.40059
-2.40059
-2.70066
-2.70066
-3.00073
-3.00073
-3.30081
-3.30081
-3.60088
-3.60088
-3.90095
-3.90095
-4.20102
-4.20102
-4.5011
-4.5011
-4.80117
-4.80117
-5.10124
-5.10124
-5.40132
-5.40132
-5.70139
-5.70139
-6.00146
-6.00146
-6.30154
-6.30154
-6.60161
-6.60161
-6.90168
-6.90168
-7.20176
-7.20176
-7.50183
-7.50183
-7.8019
-7.8019
-8.10198
-8.10198
-8.40205
-8.40205
-8.70212
-8.70212
-9.0022
-9.0022
-9.30227
-9.30227

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1425


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096

0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492

-9.60234
-9.60234
-9.90241
-9.90242
-10.2025
-10.2025
-10.5026
-10.5026
-10.8026
-10.8026
-11.1027
-11.1027
-11.4028
-11.4028
-11.7029
-11.7029
-12.0029
-12.0029
-12.303
-12.303
-12.6031
-12.6031
-12.903
-12.903
-13.2031
-13.2031
-13.5032
-13.5032
-13.8032
-13.8032
-14.1033
-14.1033
-14.4034
-14.4034
-14.7034
-14.7034
-15.0035
-15.0035
-15.3036
-15.3036
-15.6037
-15.6037
-15.9037
-15.9037
-16.2038
-16.2038
-16.5039
-16.5039
-16.804
-16.804
-17.104
-17.104
-17.4041
-17.4041
-17.7042
-17.7042
-18.0042
-18.0042
-18.3043
-18.3043
-18.6044
-18.6044
-18.9045
-18.9045
-19.2045
-19.2045
-19.5046
-19.5046
-19.8047

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1426 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
4097
GRID
4098
GRID
4099
GRID
4100
GRID
4101
GRID
4102
GRID
4103
GRID
4104
GRID
4105
GRID
4106
GRID
4107
GRID
4108
GRID
4109
GRID
4110
GRID
4111
GRID
4112
GRID
4113
GRID
4114
GRID
4115
GRID
4116
GRID
4117
GRID
4118
GRID
4119
GRID
4120
GRID
4121
GRID
4122
GRID
4123
GRID
4124
GRID
4125
GRID
4126
GRID
4127
GRID
4128
GRID
4129
GRID
4130
GRID
4131
GRID
4132
GRID
4133
GRID
6776
GRID
6777
GRID
6778
GRID
6779
GRID
6780
GRID
6781
GRID
6782
GRID
6783
GRID
6784
GRID
6785
GRID
6786
GRID
6787
GRID
6788
GRID
6789
GRID
6790
GRID
6791
GRID
6792
GRID
6793
GRID
6794
GRID
6795
GRID
6796
GRID
6797
GRID
6798
GRID
6799
GRID
6800
$$
$$ SPOINT Data
$$
$
$ CQUAD4 Elements
$
CQUAD4
5627

Altair Engineering

0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
0.246
0.492
-0.246
0.246
0.0
-0.492
-0.492
-0.246
0.0
0.246
0.492
0.492
0.246
-0.246
0.0
0.492
0.492
0.246
0.0
-0.246
-0.492
-0.492
-0.492
-0.246
0.0
0.246
0.492

-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.492
-0.246
-0.246
-0.246
-0.246
-0.492
-0.492
-0.492
-0.492
-0.492
-0.246
0.246
0.246
0.246
0.246
0.492
0.492
0.492
0.492
0.492
0.246
0.0
0.0
0.0
0.0
0.0

6778

-19.8047
-20.1048
-20.1048
-20.4048
-20.4048
-20.7049
-20.7049
-21.005
-21.005
-21.3051
-21.3051
-21.6051
-21.6051
-21.9052
-21.9052
-22.2053
-22.2053
-22.5053
-22.5053
-22.8054
-22.8054
-23.1055
-23.1055
-23.4056
-23.4056
-23.7056
-23.7056
-24.0057
-24.0057
-24.3058
-24.3058
-24.6059
-24.6059
-24.9059
-24.9059
-25.206
-25.206
8.589-16
-8.59-16
0.0
1.718-15
1.718-15
8.589-16
0.0
-8.59-16
-1.72-15
-1.72-15
-8.59-16
8.589-16
0.0
-1.72-15
-1.72-15
-8.59-16
0.0
8.589-16
1.718-15
1.718-15
1.718-15
8.589-16
0.0
-8.59-16
-1.72-15

6798

6799

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

6777

OptiStruct 13.0 Reference Guide 1427


Proprietary Information of Altair Engineering

CQUAD4
5629
1
6782
CQUAD4
6116
1
6777
CQUAD4
6122
1
6783
CQUAD4
6125
1
6799
CQUAD4
6520
1
6779
CQUAD4
6521
1
6776
CQUAD4
6523
1
6780
CQUAD4
6528
1
6781
CQUAD4
6954
1
6797
CQUAD4
7220
1
6788
CQUAD4
7647
1
6787
CQUAD4
7652
1
6798
CQUAD4
7945
1
6786
CQUAD4
7948
1
6789
CQUAD4
7955
1
6800
$
$HMMOVE
5
$
5627
5629
6116
$
6528
6954
7220
$
$
$ CHEXA Elements: First Order
$
CHEXA
17
2
10
+
36
37
CHEXA
18
2
34
+
40
41
CHEXA
19
2
38
+
44
45
CHEXA
20
2
42
+
48
49
CHEXA
21
2
46
+
52
53
CHEXA
22
2
50
+
56
57
CHEXA
23
2
54
+
60
61
CHEXA
24
2
58
+
64
65
CHEXA
25
2
62
+
68
69
CHEXA
26
2
66
+
72
73
CHEXA
27
2
70
+
76
77
CHEXA
28
2
74
+
80
81
CHEXA
29
2
78
+
84
85
CHEXA
30
2
82
+
88
89
CHEXA
31
2
86
+
92
93
CHEXA
32
2
90
+
96
97
CHEXA
33
2
94
+
100
101
CHEXA
34
2
98
+
104
105
CHEXA
35
2
102
+
108
109
CHEXA
36
2
106
+
112
113
CHEXA
37
2
110
+
116
117
CHEXA
38
2
114
+
120
121
CHEXA
39
2
118
+
124
125

6778
6799
6777
6798
6796
6797
6779
6776
6796
6787
6795
6797
6788
6786
6799

6777
6800
6785
6788
6797
6798
6776
6778
6795
6793
6794
6787
6792
6791
6786

6783
6785
6784
6786
6776
6778
6781
6782
6787
6792
6793
6788
6791
6790
6789

6122
7647

6125
7652

6520THRU
7945
7948

11

21

23

34

35

35

36

37

38

39

39

40

41

42

43

43

44

45

46

47

47

48

49

50

51

51

52

53

54

55

55

56

57

58

59

59

60

61

62

63

63

64

65

66

67

67

68

69

70

71

71

72

73

74

75

75

76

77

78

79

79

80

81

82

83

83

84

85

86

87

87

88

89

90

91

91

92

93

94

95

95

96

97

98

99

99

100

101

102

103

103

104

105

106

107

107

108

109

110

111

111

112

113

114

115

115

116

117

118

119

119

120

121

122

123

1428 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

6521
7955

6523

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

40
128
41
132
42
136
43
140
44
144
45
148
46
152
47
156
48
160
49
164
50
168
51
172
52
176
53
180
54
184
55
188
56
192
57
196
58
200
139
524
140
528
141
532
142
536
143
540
144
544
145
548
146
552
147
556
148
560
149
564
150
568
151
572
152
576
153
580
154

Altair Engineering

2
129
2
133
2
137
2
141
2
145
2
149
2
153
2
157
2
161
2
165
2
169
2
173
2
177
2
181
2
185
2
189
2
193
2
197
2
201
2
525
2
529
2
533
2
537
2
541
2
545
2
549
2
553
2
557
2
561
2
565
2
569
2
573
2
577
2
581
2

122

123

124

125

126

127

126

127

128

129

130

131

130

131

132

133

134

135

134

135

136

137

138

139

138

139

140

141

142

143

142

143

144

145

146

147

146

147

148

149

150

151

150

151

152

153

154

155

154

155

156

157

158

159

158

159

160

161

162

163

162

163

164

165

166

167

166

167

168

169

170

171

170

171

172

173

174

175

174

175

176

177

178

179

178

179

180

181

182

183

182

183

184

185

186

187

186

187

188

189

190

191

190

191

192

193

194

195

194

195

196

197

198

199

198

199

200

201

522

523

522

523

524

525

526

527

526

527

528

529

530

531

530

531

532

533

534

535

534

535

536

537

538

539

538

539

540

541

542

543

542

543

544

545

546

547

546

547

548

549

550

551

550

551

552

553

554

555

554

555

556

557

558

559

558

559

560

561

562

563

562

563

564

565

566

567

566

567

568

569

570

571

570

571

572

573

574

575

574

575

576

577

578

579

578

579

580

581

582

583

OptiStruct 13.0 Reference Guide 1429


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

584
155
588
156
592
157
596
158
600
159
604
160
608
161
612
162
616
163
620
164
624
165
628
166
632
167
636
168
640
169
644
170
648
171
652
172
656
173
660
174
664
175
668
176
672
177
676
178
680
179
684
180
688
181
37
182
41
183
45
184
49
185
53
186
57
187
61
188
65

585
2
589
2
593
2
597
2
601
2
605
2
609
2
613
2
617
2
621
2
625
2
629
2
633
2
637
2
641
2
645
2
649
2
653
2
657
2
661
2
665
2
669
2
673
2
677
2
681
2
685
2
689
2
691
2
693
2
695
2
697
2
699
2
701
2
703
2
705

582

583

584

585

586

587

586

587

588

589

590

591

590

591

592

593

594

595

594

595

596

597

598

599

598

599

600

601

602

603

602

603

604

605

606

607

606

607

608

609

610

611

610

611

612

613

614

615

614

615

616

617

618

619

618

619

620

621

622

623

622

623

624

625

626

627

626

627

628

629

630

631

630

631

632

633

634

635

634

635

636

637

638

639

638

639

640

641

642

643

642

643

644

645

646

647

646

647

648

649

650

651

650

651

652

653

654

655

654

655

656

657

658

659

658

659

660

661

662

663

662

663

664

665

666

667

666

667

668

669

670

671

670

671

672

673

674

675

674

675

676

677

678

679

678

679

680

681

682

683

682

683

684

685

686

687

10

23

20

690

34

690

34

37

691

692

38

692

38

41

693

694

42

694

42

45

695

696

46

696

46

49

697

698

50

698

50

53

699

700

54

700

54

57

701

702

58

702

58

61

703

704

62

1430 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

189
69
190
73
191
77
192
81
193
85
194
89
195
93
196
97
197
101
198
105
199
109
200
113
201
117
202
121
203
125
204
129
205
133
206
137
207
141
208
145
209
149
210
153
211
157
212
161
213
165
214
169
215
173
216
177
217
181
218
185
219
189
220
193
221
197
222
201
303

Altair Engineering

2
707
2
709
2
711
2
713
2
715
2
717
2
719
2
721
2
723
2
725
2
727
2
729
2
731
2
733
2
735
2
737
2
739
2
741
2
743
2
745
2
747
2
749
2
751
2
753
2
755
2
757
2
759
2
761
2
763
2
765
2
767
2
769
2
771
2
773
2

704

62

65

705

706

66

706

66

69

707

708

70

708

70

73

709

710

74

710

74

77

711

712

78

712

78

81

713

714

82

714

82

85

715

716

86

716

86

89

717

718

90

718

90

93

719

720

94

720

94

97

721

722

98

722

98

101

723

724

102

724

102

105

725

726

106

726

106

109

727

728

110

728

110

113

729

730

114

730

114

117

731

732

118

732

118

121

733

734

122

734

122

125

735

736

126

736

126

129

737

738

130

738

130

133

739

740

134

740

134

137

741

742

138

742

138

141

743

744

142

744

142

145

745

746

146

746

146

149

747

748

150

748

150

153

749

750

154

750

154

157

751

752

158

752

158

161

753

754

162

754

162

165

755

756

166

756

166

169

757

758

170

758

170

173

759

760

174

760

174

177

761

762

178

762

178

181

763

764

182

764

182

185

765

766

186

766

186

189

767

768

190

768

190

193

769

770

194

770

194

197

771

772

198

772

198

201

773

934

522

OptiStruct 13.0 Reference Guide 1431


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

525
304
529
305
533
306
537
307
541
308
545
309
549
310
553
311
557
312
561
313
565
314
569
315
573
316
577
317
581
318
585
319
589
320
593
321
597
322
601
323
605
324
609
325
613
326
617
327
621
328
625
329
629
330
633
331
637
332
641
333
645
334
649
335
653
336
657
337
661

935
2
937
2
939
2
941
2
943
2
945
2
947
2
949
2
951
2
953
2
955
2
957
2
959
2
961
2
963
2
965
2
967
2
969
2
971
2
973
2
975
2
977
2
979
2
981
2
983
2
985
2
987
2
989
2
991
2
993
2
995
2
997
2
999
2
1001
2
1003

934

522

525

935

936

526

936

526

529

937

938

530

938

530

533

939

940

534

940

534

537

941

942

538

942

538

541

943

944

542

944

542

545

945

946

546

946

546

549

947

948

550

948

550

553

949

950

554

950

554

557

951

952

558

952

558

561

953

954

562

954

562

565

955

956

566

956

566

569

957

958

570

958

570

573

959

960

574

960

574

577

961

962

578

962

578

581

963

964

582

964

582

585

965

966

586

966

586

589

967

968

590

968

590

593

969

970

594

970

594

597

971

972

598

972

598

601

973

974

602

974

602

605

975

976

606

976

606

609

977

978

610

978

610

613

979

980

614

980

614

617

981

982

618

982

618

621

983

984

622

984

622

625

985

986

626

986

626

629

987

988

630

988

630

633

989

990

634

990

634

637

991

992

638

992

638

641

993

994

642

994

642

645

995

996

646

996

646

649

997

998

650

998

650

653

999

1000

654

1000

654

657

1001

1002

658

1432 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

338
665
339
669
340
673
341
677
342
681
343
685
344
689
345
1018
346
1020
347
1022
348
1024
349
1026
350
1028
351
1030
352
1032
353
1034
354
1036
355
1038
356
1040
357
1042
358
1044
359
1046
360
1048
361
1050
362
1052
363
1054
364
1056
365
1058
366
1060
367
1062
368
1064
369
1066
370
1068
371
1070
372

Altair Engineering

2
1005
2
1007
2
1009
2
1011
2
1013
2
1015
2
1017
2
1019
2
1021
2
1023
2
1025
2
1027
2
1029
2
1031
2
1033
2
1035
2
1037
2
1039
2
1041
2
1043
2
1045
2
1047
2
1049
2
1051
2
1053
2
1055
2
1057
2
1059
2
1061
2
1063
2
1065
2
1067
2
1069
2
1071
2

1002

658

661

1003

1004

662

1004

662

665

1005

1006

666

1006

666

669

1007

1008

670

1008

670

673

1009

1010

674

1010

674

677

1011

1012

678

1012

678

681

1013

1014

682

1014

682

685

1015

1016

686

23

21

17

18

37

36

37

36

1018

1019

41

40

41

40

1020

1021

45

44

45

44

1022

1023

49

48

49

48

1024

1025

53

52

53

52

1026

1027

57

56

57

56

1028

1029

61

60

61

60

1030

1031

65

64

65

64

1032

1033

69

68

69

68

1034

1035

73

72

73

72

1036

1037

77

76

77

76

1038

1039

81

80

81

80

1040

1041

85

84

85

84

1042

1043

89

88

89

88

1044

1045

93

92

93

92

1046

1047

97

96

97

96

1048

1049

101

100

101

100

1050

1051

105

104

105

104

1052

1053

109

108

109

108

1054

1055

113

112

113

112

1056

1057

117

116

117

116

1058

1059

121

120

121

120

1060

1061

125

124

125

124

1062

1063

129

128

129

128

1064

1065

133

132

133

132

1066

1067

137

136

137

136

1068

1069

141

140

141

140

1070

1071

145

144

OptiStruct 13.0 Reference Guide 1433


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1072
373
1074
374
1076
375
1078
376
1080
377
1082
378
1084
379
1086
380
1088
381
1090
382
1092
383
1094
384
1096
385
1098
386
1100
467
1262
468
1264
469
1266
470
1268
471
1270
472
1272
473
1274
474
1276
475
1278
476
1280
477
1282
478
1284
479
1286
480
1288
481
1290
482
1292
483
1294
484
1296
485
1298
486
1300

1073
2
1075
2
1077
2
1079
2
1081
2
1083
2
1085
2
1087
2
1089
2
1091
2
1093
2
1095
2
1097
2
1099
2
1101
2
1263
2
1265
2
1267
2
1269
2
1271
2
1273
2
1275
2
1277
2
1279
2
1281
2
1283
2
1285
2
1287
2
1289
2
1291
2
1293
2
1295
2
1297
2
1299
2
1301

145

144

1072

1073

149

148

149

148

1074

1075

153

152

153

152

1076

1077

157

156

157

156

1078

1079

161

160

161

160

1080

1081

165

164

165

164

1082

1083

169

168

169

168

1084

1085

173

172

173

172

1086

1087

177

176

177

176

1088

1089

181

180

181

180

1090

1091

185

184

185

184

1092

1093

189

188

189

188

1094

1095

193

192

193

192

1096

1097

197

196

197

196

1098

1099

201

200

201

200

1100

1101

525

524

525

524

1262

1263

529

528

529

528

1264

1265

533

532

533

532

1266

1267

537

536

537

536

1268

1269

541

540

541

540

1270

1271

545

544

545

544

1272

1273

549

548

549

548

1274

1275

553

552

553

552

1276

1277

557

556

557

556

1278

1279

561

560

561

560

1280

1281

565

564

565

564

1282

1283

569

568

569

568

1284

1285

573

572

573

572

1286

1287

577

576

577

576

1288

1289

581

580

581

580

1290

1291

585

584

585

584

1292

1293

589

588

589

588

1294

1295

593

592

593

592

1296

1297

597

596

597

596

1298

1299

601

600

1434 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

487
1302
488
1304
489
1306
490
1308
491
1310
492
1312
493
1314
494
1316
495
1318
496
1320
497
1322
498
1324
499
1326
500
1328
501
1330
502
1332
503
1334
504
1336
505
1338
506
1340
507
1342
508
1344
509
1019
510
1021
511
1023
512
1025
513
1027
514
1029
515
1031
516
1033
517
1035
518
1037
519
1039
520
1041
521

Altair Engineering

2
1303
2
1305
2
1307
2
1309
2
1311
2
1313
2
1315
2
1317
2
1319
2
1321
2
1323
2
1325
2
1327
2
1329
2
1331
2
1333
2
1335
2
1337
2
1339
2
1341
2
1343
2
1345
2
1346
2
1347
2
1348
2
1349
2
1350
2
1351
2
1352
2
1353
2
1354
2
1355
2
1356
2
1357
2

601

600

1300

1301

605

604

605

604

1302

1303

609

608

609

608

1304

1305

613

612

613

612

1306

1307

617

616

617

616

1308

1309

621

620

621

620

1310

1311

625

624

625

624

1312

1313

629

628

629

628

1314

1315

633

632

633

632

1316

1317

637

636

637

636

1318

1319

641

640

641

640

1320

1321

645

644

645

644

1322

1323

649

648

649

648

1324

1325

653

652

653

652

1326

1327

657

656

657

656

1328

1329

661

660

661

660

1330

1331

665

664

665

664

1332

1333

669

668

669

668

1334

1335

673

672

673

672

1336

1337

677

676

677

676

1338

1339

681

680

681

680

1340

1341

685

684

685

684

1342

1343

689

688

20

23

18

19

691

37

691

37

1019

1346

693

41

693

41

1021

1347

695

45

695

45

1023

1348

697

49

697

49

1025

1349

699

53

699

53

1027

1350

701

57

701

57

1029

1351

703

61

703

61

1031

1352

705

65

705

65

1033

1353

707

69

707

69

1035

1354

709

73

709

73

1037

1355

711

77

711

77

1039

1356

713

81

713

81

1041

1357

715

85

OptiStruct 13.0 Reference Guide 1435


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1043
522
1045
523
1047
524
1049
525
1051
526
1053
527
1055
528
1057
529
1059
530
1061
531
1063
532
1065
533
1067
534
1069
535
1071
536
1073
537
1075
538
1077
539
1079
540
1081
541
1083
542
1085
543
1087
544
1089
545
1091
546
1093
547
1095
548
1097
549
1099
550
1101
631
1263
632
1265
633
1267
634
1269
635
1271

1358
2
1359
2
1360
2
1361
2
1362
2
1363
2
1364
2
1365
2
1366
2
1367
2
1368
2
1369
2
1370
2
1371
2
1372
2
1373
2
1374
2
1375
2
1376
2
1377
2
1378
2
1379
2
1380
2
1381
2
1382
2
1383
2
1384
2
1385
2
1386
2
1387
2
1468
2
1469
2
1470
2
1471
2
1472

715

85

1043

1358

717

89

717

89

1045

1359

719

93

719

93

1047

1360

721

97

721

97

1049

1361

723

101

723

101

1051

1362

725

105

725

105

1053

1363

727

109

727

109

1055

1364

729

113

729

113

1057

1365

731

117

731

117

1059

1366

733

121

733

121

1061

1367

735

125

735

125

1063

1368

737

129

737

129

1065

1369

739

133

739

133

1067

1370

741

137

741

137

1069

1371

743

141

743

141

1071

1372

745

145

745

145

1073

1373

747

149

747

149

1075

1374

749

153

749

153

1077

1375

751

157

751

157

1079

1376

753

161

753

161

1081

1377

755

165

755

165

1083

1378

757

169

757

169

1085

1379

759

173

759

173

1087

1380

761

177

761

177

1089

1381

763

181

763

181

1091

1382

765

185

765

185

1093

1383

767

189

767

189

1095

1384

769

193

769

193

1097

1385

771

197

771

197

1099

1386

773

201

773

201

1101

1387

935

525

935

525

1263

1468

937

529

937

529

1265

1469

939

533

939

533

1267

1470

941

537

941

537

1269

1471

943

541

1436 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

636
1273
637
1275
638
1277
639
1279
640
1281
641
1283
642
1285
643
1287
644
1289
645
1291
646
1293
647
1295
648
1297
649
1299
650
1301
651
1303
652
1305
653
1307
654
1309
655
1311
656
1313
657
1315
658
1317
659
1319
660
1321
661
1323
662
1325
663
1327
664
1329
665
1331
666
1333
667
1335
668
1337
669
1339
670

Altair Engineering

2
1473
2
1474
2
1475
2
1476
2
1477
2
1478
2
1479
2
1480
2
1481
2
1482
2
1483
2
1484
2
1485
2
1486
2
1487
2
1488
2
1489
2
1490
2
1491
2
1492
2
1493
2
1494
2
1495
2
1496
2
1497
2
1498
2
1499
2
1500
2
1501
2
1502
2
1503
2
1504
2
1505
2
1506
2

943

541

1271

1472

945

545

945

545

1273

1473

947

549

947

549

1275

1474

949

553

949

553

1277

1475

951

557

951

557

1279

1476

953

561

953

561

1281

1477

955

565

955

565

1283

1478

957

569

957

569

1285

1479

959

573

959

573

1287

1480

961

577

961

577

1289

1481

963

581

963

581

1291

1482

965

585

965

585

1293

1483

967

589

967

589

1295

1484

969

593

969

593

1297

1485

971

597

971

597

1299

1486

973

601

973

601

1301

1487

975

605

975

605

1303

1488

977

609

977

609

1305

1489

979

613

979

613

1307

1490

981

617

981

617

1309

1491

983

621

983

621

1311

1492

985

625

985

625

1313

1493

987

629

987

629

1315

1494

989

633

989

633

1317

1495

991

637

991

637

1319

1496

993

641

993

641

1321

1497

995

645

995

645

1323

1498

997

649

997

649

1325

1499

999

653

999

653

1327

1500

1001

657

1001

657

1329

1501

1003

661

1003

661

1331

1502

1005

665

1005

665

1333

1503

1007

669

1007

669

1335

1504

1009

673

1009

673

1337

1505

1011

677

1011

677

1339

1506

1013

681

OptiStruct 13.0 Reference Guide 1437


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1341
671
1343
672
1345
673
1512
674
1516
675
1520
676
1524
677
1528
678
1532
679
1536
680
1540
681
1544
682
1548
683
1552
684
1556
685
1560
686
1564
687
1568
688
1572
689
1576
690
1580
691
1584
692
1588
693
1592
694
1596
695
1600
696
1604
697
1608
698
1612
699
1616
700
1620
701
1624
702
1628
703
1632
704
1636

1507
2
1508
2
1509
2
1513
2
1517
2
1521
2
1525
2
1529
2
1533
2
1537
2
1541
2
1545
2
1549
2
1553
2
1557
2
1561
2
1565
2
1569
2
1573
2
1577
2
1581
2
1585
2
1589
2
1593
2
1597
2
1601
2
1605
2
1609
2
1613
2
1617
2
1621
2
1625
2
1629
2
1633
2
1637

1013

681

1341

1507

1015

685

1015

685

1343

1508

1017

689

12

13

14

22

1510

1511

1510

1511

1512

1513

1514

1515

1514

1515

1516

1517

1518

1519

1518

1519

1520

1521

1522

1523

1522

1523

1524

1525

1526

1527

1526

1527

1528

1529

1530

1531

1530

1531

1532

1533

1534

1535

1534

1535

1536

1537

1538

1539

1538

1539

1540

1541

1542

1543

1542

1543

1544

1545

1546

1547

1546

1547

1548

1549

1550

1551

1550

1551

1552

1553

1554

1555

1554

1555

1556

1557

1558

1559

1558

1559

1560

1561

1562

1563

1562

1563

1564

1565

1566

1567

1566

1567

1568

1569

1570

1571

1570

1571

1572

1573

1574

1575

1574

1575

1576

1577

1578

1579

1578

1579

1580

1581

1582

1583

1582

1583

1584

1585

1586

1587

1586

1587

1588

1589

1590

1591

1590

1591

1592

1593

1594

1595

1594

1595

1596

1597

1598

1599

1598

1599

1600

1601

1602

1603

1602

1603

1604

1605

1606

1607

1606

1607

1608

1609

1610

1611

1610

1611

1612

1613

1614

1615

1614

1615

1616

1617

1618

1619

1618

1619

1620

1621

1622

1623

1622

1623

1624

1625

1626

1627

1626

1627

1628

1629

1630

1631

1630

1631

1632

1633

1634

1635

1438 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

705
1640
706
1644
707
1648
708
1652
709
1656
710
1660
711
1664
712
1668
713
1672
714
1676
795
2000
796
2004
797
2008
798
2012
799
2016
800
2020
801
2024
802
2028
803
2032
804
2036
805
2040
806
2044
807
2048
808
2052
809
2056
810
2060
811
2064
812
2068
813
2072
814
2076
815
2080
816
2084
817
2088
818
2092
819

Altair Engineering

2
1641
2
1645
2
1649
2
1653
2
1657
2
1661
2
1665
2
1669
2
1673
2
1677
2
2001
2
2005
2
2009
2
2013
2
2017
2
2021
2
2025
2
2029
2
2033
2
2037
2
2041
2
2045
2
2049
2
2053
2
2057
2
2061
2
2065
2
2069
2
2073
2
2077
2
2081
2
2085
2
2089
2
2093
2

1634

1635

1636

1637

1638

1639

1638

1639

1640

1641

1642

1643

1642

1643

1644

1645

1646

1647

1646

1647

1648

1649

1650

1651

1650

1651

1652

1653

1654

1655

1654

1655

1656

1657

1658

1659

1658

1659

1660

1661

1662

1663

1662

1663

1664

1665

1666

1667

1666

1667

1668

1669

1670

1671

1670

1671

1672

1673

1674

1675

1674

1675

1676

1677

1998

1999

1998

1999

2000

2001

2002

2003

2002

2003

2004

2005

2006

2007

2006

2007

2008

2009

2010

2011

2010

2011

2012

2013

2014

2015

2014

2015

2016

2017

2018

2019

2018

2019

2020

2021

2022

2023

2022

2023

2024

2025

2026

2027

2026

2027

2028

2029

2030

2031

2030

2031

2032

2033

2034

2035

2034

2035

2036

2037

2038

2039

2038

2039

2040

2041

2042

2043

2042

2043

2044

2045

2046

2047

2046

2047

2048

2049

2050

2051

2050

2051

2052

2053

2054

2055

2054

2055

2056

2057

2058

2059

2058

2059

2060

2061

2062

2063

2062

2063

2064

2065

2066

2067

2066

2067

2068

2069

2070

2071

2070

2071

2072

2073

2074

2075

2074

2075

2076

2077

2078

2079

2078

2079

2080

2081

2082

2083

2082

2083

2084

2085

2086

2087

2086

2087

2088

2089

2090

2091

2090

2091

2092

2093

2094

2095

OptiStruct 13.0 Reference Guide 1439


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2096
820
2100
821
2104
822
2108
823
2112
824
2116
825
2120
826
2124
827
2128
828
2132
829
2136
830
2140
831
2144
832
2148
833
2152
834
2156
835
2160
836
2164
837
1513
838
1517
839
1521
840
1525
841
1529
842
1533
843
1537
844
1541
845
1545
846
1549
847
1553
848
1557
849
1561
850
1565
851
1569
852
1573
853
1577

2097
2
2101
2
2105
2
2109
2
2113
2
2117
2
2121
2
2125
2
2129
2
2133
2
2137
2
2141
2
2145
2
2149
2
2153
2
2157
2
2161
2
2165
2
36
2
40
2
44
2
48
2
52
2
56
2
60
2
64
2
68
2
72
2
76
2
80
2
84
2
88
2
92
2
96
2
100

2094

2095

2096

2097

2098

2099

2098

2099

2100

2101

2102

2103

2102

2103

2104

2105

2106

2107

2106

2107

2108

2109

2110

2111

2110

2111

2112

2113

2114

2115

2114

2115

2116

2117

2118

2119

2118

2119

2120

2121

2122

2123

2122

2123

2124

2125

2126

2127

2126

2127

2128

2129

2130

2131

2130

2131

2132

2133

2134

2135

2134

2135

2136

2137

2138

2139

2138

2139

2140

2141

2142

2143

2142

2143

2144

2145

2146

2147

2146

2147

2148

2149

2150

2151

2150

2151

2152

2153

2154

2155

2154

2155

2156

2157

2158

2159

2158

2159

2160

2161

2162

2163

11

12

22

21

35

1510

35

1510

1513

36

39

1514

39

1514

1517

40

43

1518

43

1518

1521

44

47

1522

47

1522

1525

48

51

1526

51

1526

1529

52

55

1530

55

1530

1533

56

59

1534

59

1534

1537

60

63

1538

63

1538

1541

64

67

1542

67

1542

1545

68

71

1546

71

1546

1549

72

75

1550

75

1550

1553

76

79

1554

79

1554

1557

80

83

1558

83

1558

1561

84

87

1562

87

1562

1565

88

91

1566

91

1566

1569

92

95

1570

95

1570

1573

96

99

1574

1440 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

854
1581
855
1585
856
1589
857
1593
858
1597
859
1601
860
1605
861
1609
862
1613
863
1617
864
1621
865
1625
866
1629
867
1633
868
1637
869
1641
870
1645
871
1649
872
1653
873
1657
874
1661
875
1665
876
1669
877
1673
878
1677
959
2001
960
2005
961
2009
962
2013
963
2017
964
2021
965
2025
966
2029
967
2033
968

Altair Engineering

2
104
2
108
2
112
2
116
2
120
2
124
2
128
2
132
2
136
2
140
2
144
2
148
2
152
2
156
2
160
2
164
2
168
2
172
2
176
2
180
2
184
2
188
2
192
2
196
2
200
2
524
2
528
2
532
2
536
2
540
2
544
2
548
2
552
2
556
2

99

1574

1577

100

103

1578

103

1578

1581

104

107

1582

107

1582

1585

108

111

1586

111

1586

1589

112

115

1590

115

1590

1593

116

119

1594

119

1594

1597

120

123

1598

123

1598

1601

124

127

1602

127

1602

1605

128

131

1606

131

1606

1609

132

135

1610

135

1610

1613

136

139

1614

139

1614

1617

140

143

1618

143

1618

1621

144

147

1622

147

1622

1625

148

151

1626

151

1626

1629

152

155

1630

155

1630

1633

156

159

1634

159

1634

1637

160

163

1638

163

1638

1641

164

167

1642

167

1642

1645

168

171

1646

171

1646

1649

172

175

1650

175

1650

1653

176

179

1654

179

1654

1657

180

183

1658

183

1658

1661

184

187

1662

187

1662

1665

188

191

1666

191

1666

1669

192

195

1670

195

1670

1673

196

199

1674

199

1674

1677

200

523

1998

523

1998

2001

524

527

2002

527

2002

2005

528

531

2006

531

2006

2009

532

535

2010

535

2010

2013

536

539

2014

539

2014

2017

540

543

2018

543

2018

2021

544

547

2022

547

2022

2025

548

551

2026

551

2026

2029

552

555

2030

555

2030

2033

556

559

2034

OptiStruct 13.0 Reference Guide 1441


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2037
969
2041
970
2045
971
2049
972
2053
973
2057
974
2061
975
2065
976
2069
977
2073
978
2077
979
2081
980
2085
981
2089
982
2093
983
2097
984
2101
985
2105
986
2109
987
2113
988
2117
989
2121
990
2125
991
2129
992
2133
993
2137
994
2141
995
2145
996
2149
997
2153
998
2157
999
2161
1000
2165
1001
2166
1002
2168

560
2
564
2
568
2
572
2
576
2
580
2
584
2
588
2
592
2
596
2
600
2
604
2
608
2
612
2
616
2
620
2
624
2
628
2
632
2
636
2
640
2
644
2
648
2
652
2
656
2
660
2
664
2
668
2
672
2
676
2
680
2
684
2
688
2
2167
2
2169

559

2034

2037

560

563

2038

563

2038

2041

564

567

2042

567

2042

2045

568

571

2046

571

2046

2049

572

575

2050

575

2050

2053

576

579

2054

579

2054

2057

580

583

2058

583

2058

2061

584

587

2062

587

2062

2065

588

591

2066

591

2066

2069

592

595

2070

595

2070

2073

596

599

2074

599

2074

2077

600

603

2078

603

2078

2081

604

607

2082

607

2082

2085

608

611

2086

611

2086

2089

612

615

2090

615

2090

2093

616

619

2094

619

2094

2097

620

623

2098

623

2098

2101

624

627

2102

627

2102

2105

628

631

2106

631

2106

2109

632

635

2110

635

2110

2113

636

639

2114

639

2114

2117

640

643

2118

643

2118

2121

644

647

2122

647

2122

2125

648

651

2126

651

2126

2129

652

655

2130

655

2130

2133

656

659

2134

659

2134

2137

660

663

2138

663

2138

2141

664

667

2142

667

2142

2145

668

671

2146

671

2146

2149

672

675

2150

675

2150

2153

676

679

2154

679

2154

2157

680

683

2158

683

2158

2161

684

687

2162

22

14

15

16

1513

1512

1513

1512

2166

2167

1517

1516

1442 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1003
2170
1004
2172
1005
2174
1006
2176
1007
2178
1008
2180
1009
2182
1010
2184
1011
2186
1012
2188
1013
2190
1014
2192
1015
2194
1016
2196
1017
2198
1018
2200
1019
2202
1020
2204
1021
2206
1022
2208
1023
2210
1024
2212
1025
2214
1026
2216
1027
2218
1028
2220
1029
2222
1030
2224
1031
2226
1032
2228
1033
2230
1034
2232
1035
2234
1036
2236
1037

Altair Engineering

2
2171
2
2173
2
2175
2
2177
2
2179
2
2181
2
2183
2
2185
2
2187
2
2189
2
2191
2
2193
2
2195
2
2197
2
2199
2
2201
2
2203
2
2205
2
2207
2
2209
2
2211
2
2213
2
2215
2
2217
2
2219
2
2221
2
2223
2
2225
2
2227
2
2229
2
2231
2
2233
2
2235
2
2237
2

1517

1516

2168

2169

1521

1520

1521

1520

2170

2171

1525

1524

1525

1524

2172

2173

1529

1528

1529

1528

2174

2175

1533

1532

1533

1532

2176

2177

1537

1536

1537

1536

2178

2179

1541

1540

1541

1540

2180

2181

1545

1544

1545

1544

2182

2183

1549

1548

1549

1548

2184

2185

1553

1552

1553

1552

2186

2187

1557

1556

1557

1556

2188

2189

1561

1560

1561

1560

2190

2191

1565

1564

1565

1564

2192

2193

1569

1568

1569

1568

2194

2195

1573

1572

1573

1572

2196

2197

1577

1576

1577

1576

2198

2199

1581

1580

1581

1580

2200

2201

1585

1584

1585

1584

2202

2203

1589

1588

1589

1588

2204

2205

1593

1592

1593

1592

2206

2207

1597

1596

1597

1596

2208

2209

1601

1600

1601

1600

2210

2211

1605

1604

1605

1604

2212

2213

1609

1608

1609

1608

2214

2215

1613

1612

1613

1612

2216

2217

1617

1616

1617

1616

2218

2219

1621

1620

1621

1620

2220

2221

1625

1624

1625

1624

2222

2223

1629

1628

1629

1628

2224

2225

1633

1632

1633

1632

2226

2227

1637

1636

1637

1636

2228

2229

1641

1640

1641

1640

2230

2231

1645

1644

1645

1644

2232

2233

1649

1648

1649

1648

2234

2235

1653

1652

1653

1652

2236

2237

1657

1656

OptiStruct 13.0 Reference Guide 1443


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2238
1038
2240
1039
2242
1040
2244
1041
2246
1042
2248
1123
2410
1124
2412
1125
2414
1126
2416
1127
2418
1128
2420
1129
2422
1130
2424
1131
2426
1132
2428
1133
2430
1134
2432
1135
2434
1136
2436
1137
2438
1138
2440
1139
2442
1140
2444
1141
2446
1142
2448
1143
2450
1144
2452
1145
2454
1146
2456
1147
2458
1148
2460
1149
2462
1150
2464
1151
2466

2239
2
2241
2
2243
2
2245
2
2247
2
2249
2
2411
2
2413
2
2415
2
2417
2
2419
2
2421
2
2423
2
2425
2
2427
2
2429
2
2431
2
2433
2
2435
2
2437
2
2439
2
2441
2
2443
2
2445
2
2447
2
2449
2
2451
2
2453
2
2455
2
2457
2
2459
2
2461
2
2463
2
2465
2
2467

1657

1656

2238

2239

1661

1660

1661

1660

2240

2241

1665

1664

1665

1664

2242

2243

1669

1668

1669

1668

2244

2245

1673

1672

1673

1672

2246

2247

1677

1676

1677

1676

2248

2249

2001

2000

2001

2000

2410

2411

2005

2004

2005

2004

2412

2413

2009

2008

2009

2008

2414

2415

2013

2012

2013

2012

2416

2417

2017

2016

2017

2016

2418

2419

2021

2020

2021

2020

2420

2421

2025

2024

2025

2024

2422

2423

2029

2028

2029

2028

2424

2425

2033

2032

2033

2032

2426

2427

2037

2036

2037

2036

2428

2429

2041

2040

2041

2040

2430

2431

2045

2044

2045

2044

2432

2433

2049

2048

2049

2048

2434

2435

2053

2052

2053

2052

2436

2437

2057

2056

2057

2056

2438

2439

2061

2060

2061

2060

2440

2441

2065

2064

2065

2064

2442

2443

2069

2068

2069

2068

2444

2445

2073

2072

2073

2072

2446

2447

2077

2076

2077

2076

2448

2449

2081

2080

2081

2080

2450

2451

2085

2084

2085

2084

2452

2453

2089

2088

2089

2088

2454

2455

2093

2092

2093

2092

2456

2457

2097

2096

2097

2096

2458

2459

2101

2100

2101

2100

2460

2461

2105

2104

2105

2104

2462

2463

2109

2108

2109

2108

2464

2465

2113

2112

1444 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1152
2468
1153
2470
1154
2472
1155
2474
1156
2476
1157
2478
1158
2480
1159
2482
1160
2484
1161
2486
1162
2488
1163
2490
1164
2492
1165
2167
1166
2169
1167
2171
1168
2173
1169
2175
1170
2177
1171
2179
1172
2181
1173
2183
1174
2185
1175
2187
1176
2189
1177
2191
1178
2193
1179
2195
1180
2197
1181
2199
1182
2201
1183
2203
1184
2205
1185
2207
1186

Altair Engineering

2
2469
2
2471
2
2473
2
2475
2
2477
2
2479
2
2481
2
2483
2
2485
2
2487
2
2489
2
2491
2
2493
2
1018
2
1020
2
1022
2
1024
2
1026
2
1028
2
1030
2
1032
2
1034
2
1036
2
1038
2
1040
2
1042
2
1044
2
1046
2
1048
2
1050
2
1052
2
1054
2
1056
2
1058
2

2113

2112

2466

2467

2117

2116

2117

2116

2468

2469

2121

2120

2121

2120

2470

2471

2125

2124

2125

2124

2472

2473

2129

2128

2129

2128

2474

2475

2133

2132

2133

2132

2476

2477

2137

2136

2137

2136

2478

2479

2141

2140

2141

2140

2480

2481

2145

2144

2145

2144

2482

2483

2149

2148

2149

2148

2484

2485

2153

2152

2153

2152

2486

2487

2157

2156

2157

2156

2488

2489

2161

2160

2161

2160

2490

2491

2165

2164

21

22

16

17

36

1513

36

1513

2167

1018

40

1517

40

1517

2169

1020

44

1521

44

1521

2171

1022

48

1525

48

1525

2173

1024

52

1529

52

1529

2175

1026

56

1533

56

1533

2177

1028

60

1537

60

1537

2179

1030

64

1541

64

1541

2181

1032

68

1545

68

1545

2183

1034

72

1549

72

1549

2185

1036

76

1553

76

1553

2187

1038

80

1557

80

1557

2189

1040

84

1561

84

1561

2191

1042

88

1565

88

1565

2193

1044

92

1569

92

1569

2195

1046

96

1573

96

1573

2197

1048

100

1577

100

1577

2199

1050

104

1581

104

1581

2201

1052

108

1585

108

1585

2203

1054

112

1589

112

1589

2205

1056

116

1593

116

1593

2207

1058

120

1597

OptiStruct 13.0 Reference Guide 1445


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2209
1187
2211
1188
2213
1189
2215
1190
2217
1191
2219
1192
2221
1193
2223
1194
2225
1195
2227
1196
2229
1197
2231
1198
2233
1199
2235
1200
2237
1201
2239
1202
2241
1203
2243
1204
2245
1205
2247
1206
2249
1287
2411
1288
2413
1289
2415
1290
2417
1291
2419
1292
2421
1293
2423
1294
2425
1295
2427
1296
2429
1297
2431
1298
2433
1299
2435
1300
2437

1060
2
1062
2
1064
2
1066
2
1068
2
1070
2
1072
2
1074
2
1076
2
1078
2
1080
2
1082
2
1084
2
1086
2
1088
2
1090
2
1092
2
1094
2
1096
2
1098
2
1100
2
1262
2
1264
2
1266
2
1268
2
1270
2
1272
2
1274
2
1276
2
1278
2
1280
2
1282
2
1284
2
1286
2
1288

120

1597

2209

1060

124

1601

124

1601

2211

1062

128

1605

128

1605

2213

1064

132

1609

132

1609

2215

1066

136

1613

136

1613

2217

1068

140

1617

140

1617

2219

1070

144

1621

144

1621

2221

1072

148

1625

148

1625

2223

1074

152

1629

152

1629

2225

1076

156

1633

156

1633

2227

1078

160

1637

160

1637

2229

1080

164

1641

164

1641

2231

1082

168

1645

168

1645

2233

1084

172

1649

172

1649

2235

1086

176

1653

176

1653

2237

1088

180

1657

180

1657

2239

1090

184

1661

184

1661

2241

1092

188

1665

188

1665

2243

1094

192

1669

192

1669

2245

1096

196

1673

196

1673

2247

1098

200

1677

200

1677

2249

1100

524

2001

524

2001

2411

1262

528

2005

528

2005

2413

1264

532

2009

532

2009

2415

1266

536

2013

536

2013

2417

1268

540

2017

540

2017

2419

1270

544

2021

544

2021

2421

1272

548

2025

548

2025

2423

1274

552

2029

552

2029

2425

1276

556

2033

556

2033

2427

1278

560

2037

560

2037

2429

1280

564

2041

564

2041

2431

1282

568

2045

568

2045

2433

1284

572

2049

572

2049

2435

1286

576

2053

1446 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1301
2439
1302
2441
1303
2443
1304
2445
1305
2447
1306
2449
1307
2451
1308
2453
1309
2455
1310
2457
1311
2459
1312
2461
1313
2463
1314
2465
1315
2467
1316
2469
1317
2471
1318
2473
1319
2475
1320
2477
1321
2479
1322
2481
1323
2483
1324
2485
1325
2487
1326
2489
1327
2491
1328
2493
1329
35
1330
39
1331
43
1332
47
1333
51
1334
55
1335

Altair Engineering

2
1290
2
1292
2
1294
2
1296
2
1298
2
1300
2
1302
2
1304
2
1306
2
1308
2
1310
2
1312
2
1314
2
1316
2
1318
2
1320
2
1322
2
1324
2
1326
2
1328
2
1330
2
1332
2
1334
2
1336
2
1338
2
1340
2
1342
2
1344
2
2495
2
2497
2
2499
2
2501
2
2503
2
2505
2

576

2053

2437

1288

580

2057

580

2057

2439

1290

584

2061

584

2061

2441

1292

588

2065

588

2065

2443

1294

592

2069

592

2069

2445

1296

596

2073

596

2073

2447

1298

600

2077

600

2077

2449

1300

604

2081

604

2081

2451

1302

608

2085

608

2085

2453

1304

612

2089

612

2089

2455

1306

616

2093

616

2093

2457

1308

620

2097

620

2097

2459

1310

624

2101

624

2101

2461

1312

628

2105

628

2105

2463

1314

632

2109

632

2109

2465

1316

636

2113

636

2113

2467

1318

640

2117

640

2117

2469

1320

644

2121

644

2121

2471

1322

648

2125

648

2125

2473

1324

652

2129

652

2129

2475

1326

656

2133

656

2133

2477

1328

660

2137

660

2137

2479

1330

664

2141

664

2141

2481

1332

668

2145

668

2145

2483

1334

672

2149

672

2149

2485

1336

676

2153

676

2153

2487

1338

680

2157

680

2157

2489

1340

684

2161

684

2161

2491

1342

688

2165

33

12

11

31

2494

1510

2494

1510

35

2495

2496

1514

2496

1514

39

2497

2498

1518

2498

1518

43

2499

2500

1522

2500

1522

47

2501

2502

1526

2502

1526

51

2503

2504

1530

2504

1530

55

2505

2506

1534

OptiStruct 13.0 Reference Guide 1447


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

59
1336
63
1337
67
1338
71
1339
75
1340
79
1341
83
1342
87
1343
91
1344
95
1345
99
1346
103
1347
107
1348
111
1349
115
1350
119
1351
123
1352
127
1353
131
1354
135
1355
139
1356
143
1357
147
1358
151
1359
155
1360
159
1361
163
1362
167
1363
171
1364
175
1365
179
1366
183
1367
187
1368
191
1369
195

2507
2
2509
2
2511
2
2513
2
2515
2
2517
2
2519
2
2521
2
2523
2
2525
2
2527
2
2529
2
2531
2
2533
2
2535
2
2537
2
2539
2
2541
2
2543
2
2545
2
2547
2
2549
2
2551
2
2553
2
2555
2
2557
2
2559
2
2561
2
2563
2
2565
2
2567
2
2569
2
2571
2
2573
2
2575

2506

1534

59

2507

2508

1538

2508

1538

63

2509

2510

1542

2510

1542

67

2511

2512

1546

2512

1546

71

2513

2514

1550

2514

1550

75

2515

2516

1554

2516

1554

79

2517

2518

1558

2518

1558

83

2519

2520

1562

2520

1562

87

2521

2522

1566

2522

1566

91

2523

2524

1570

2524

1570

95

2525

2526

1574

2526

1574

99

2527

2528

1578

2528

1578

103

2529

2530

1582

2530

1582

107

2531

2532

1586

2532

1586

111

2533

2534

1590

2534

1590

115

2535

2536

1594

2536

1594

119

2537

2538

1598

2538

1598

123

2539

2540

1602

2540

1602

127

2541

2542

1606

2542

1606

131

2543

2544

1610

2544

1610

135

2545

2546

1614

2546

1614

139

2547

2548

1618

2548

1618

143

2549

2550

1622

2550

1622

147

2551

2552

1626

2552

1626

151

2553

2554

1630

2554

1630

155

2555

2556

1634

2556

1634

159

2557

2558

1638

2558

1638

163

2559

2560

1642

2560

1642

167

2561

2562

1646

2562

1646

171

2563

2564

1650

2564

1650

175

2565

2566

1654

2566

1654

179

2567

2568

1658

2568

1658

183

2569

2570

1662

2570

1662

187

2571

2572

1666

2572

1666

191

2573

2574

1670

1448 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1370
199
1451
523
1452
527
1453
531
1454
535
1455
539
1456
543
1457
547
1458
551
1459
555
1460
559
1461
563
1462
567
1463
571
1464
575
1465
579
1466
583
1467
587
1468
591
1469
595
1470
599
1471
603
1472
607
1473
611
1474
615
1475
619
1476
623
1477
627
1478
631
1479
635
1480
639
1481
643
1482
647
1483
651
1484

Altair Engineering

2
2577
2
2739
2
2741
2
2743
2
2745
2
2747
2
2749
2
2751
2
2753
2
2755
2
2757
2
2759
2
2761
2
2763
2
2765
2
2767
2
2769
2
2771
2
2773
2
2775
2
2777
2
2779
2
2781
2
2783
2
2785
2
2787
2
2789
2
2791
2
2793
2
2795
2
2797
2
2799
2
2801
2
2803
2

2574

1670

195

2575

2576

1674

2576

1674

199

2577

2738

1998

2738

1998

523

2739

2740

2002

2740

2002

527

2741

2742

2006

2742

2006

531

2743

2744

2010

2744

2010

535

2745

2746

2014

2746

2014

539

2747

2748

2018

2748

2018

543

2749

2750

2022

2750

2022

547

2751

2752

2026

2752

2026

551

2753

2754

2030

2754

2030

555

2755

2756

2034

2756

2034

559

2757

2758

2038

2758

2038

563

2759

2760

2042

2760

2042

567

2761

2762

2046

2762

2046

571

2763

2764

2050

2764

2050

575

2765

2766

2054

2766

2054

579

2767

2768

2058

2768

2058

583

2769

2770

2062

2770

2062

587

2771

2772

2066

2772

2066

591

2773

2774

2070

2774

2070

595

2775

2776

2074

2776

2074

599

2777

2778

2078

2778

2078

603

2779

2780

2082

2780

2082

607

2781

2782

2086

2782

2086

611

2783

2784

2090

2784

2090

615

2785

2786

2094

2786

2094

619

2787

2788

2098

2788

2098

623

2789

2790

2102

2790

2102

627

2791

2792

2106

2792

2106

631

2793

2794

2110

2794

2110

635

2795

2796

2114

2796

2114

639

2797

2798

2118

2798

2118

643

2799

2800

2122

2800

2122

647

2801

2802

2126

2802

2126

651

2803

2804

2130

OptiStruct 13.0 Reference Guide 1449


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

655
1485
659
1486
663
1487
667
1488
671
1489
675
1490
679
1491
683
1492
687
1493
1510
1494
1514
1495
1518
1496
1522
1497
1526
1498
1530
1499
1534
1500
1538
1501
1542
1502
1546
1503
1550
1504
1554
1505
1558
1506
1562
1507
1566
1508
1570
1509
1574
1510
1578
1511
1582
1512
1586
1513
1590
1514
1594
1515
1598
1516
1602
1517
1606
1518
1610

2805
2
2807
2
2809
2
2811
2
2813
2
2815
2
2817
2
2819
2
2821
2
2494
2
2496
2
2498
2
2500
2
2502
2
2504
2
2506
2
2508
2
2510
2
2512
2
2514
2
2516
2
2518
2
2520
2
2522
2
2524
2
2526
2
2528
2
2530
2
2532
2
2534
2
2536
2
2538
2
2540
2
2542
2
2544

2804

2130

655

2805

2806

2134

2806

2134

659

2807

2808

2138

2808

2138

663

2809

2810

2142

2810

2142

667

2811

2812

2146

2812

2146

671

2813

2814

2150

2814

2150

675

2815

2816

2154

2816

2154

679

2817

2818

2158

2818

2158

683

2819

2820

2162

30

13

12

33

2822

1511

2822

1511

1510

2494

2823

1515

2823

1515

1514

2496

2824

1519

2824

1519

1518

2498

2825

1523

2825

1523

1522

2500

2826

1527

2826

1527

1526

2502

2827

1531

2827

1531

1530

2504

2828

1535

2828

1535

1534

2506

2829

1539

2829

1539

1538

2508

2830

1543

2830

1543

1542

2510

2831

1547

2831

1547

1546

2512

2832

1551

2832

1551

1550

2514

2833

1555

2833

1555

1554

2516

2834

1559

2834

1559

1558

2518

2835

1563

2835

1563

1562

2520

2836

1567

2836

1567

1566

2522

2837

1571

2837

1571

1570

2524

2838

1575

2838

1575

1574

2526

2839

1579

2839

1579

1578

2528

2840

1583

2840

1583

1582

2530

2841

1587

2841

1587

1586

2532

2842

1591

2842

1591

1590

2534

2843

1595

2843

1595

1594

2536

2844

1599

2844

1599

1598

2538

2845

1603

2845

1603

1602

2540

2846

1607

2846

1607

1606

2542

2847

1611

1450 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1519
1614
1520
1618
1521
1622
1522
1626
1523
1630
1524
1634
1525
1638
1526
1642
1527
1646
1528
1650
1529
1654
1530
1658
1531
1662
1532
1666
1533
1670
1534
1674
1615
1998
1616
2002
1617
2006
1618
2010
1619
2014
1620
2018
1621
2022
1622
2026
1623
2030
1624
2034
1625
2038
1626
2042
1627
2046
1628
2050
1629
2054
1630
2058
1631
2062
1632
2066
1633

Altair Engineering

2
2546
2
2548
2
2550
2
2552
2
2554
2
2556
2
2558
2
2560
2
2562
2
2564
2
2566
2
2568
2
2570
2
2572
2
2574
2
2576
2
2738
2
2740
2
2742
2
2744
2
2746
2
2748
2
2750
2
2752
2
2754
2
2756
2
2758
2
2760
2
2762
2
2764
2
2766
2
2768
2
2770
2
2772
2

2847

1611

1610

2544

2848

1615

2848

1615

1614

2546

2849

1619

2849

1619

1618

2548

2850

1623

2850

1623

1622

2550

2851

1627

2851

1627

1626

2552

2852

1631

2852

1631

1630

2554

2853

1635

2853

1635

1634

2556

2854

1639

2854

1639

1638

2558

2855

1643

2855

1643

1642

2560

2856

1647

2856

1647

1646

2562

2857

1651

2857

1651

1650

2564

2858

1655

2858

1655

1654

2566

2859

1659

2859

1659

1658

2568

2860

1663

2860

1663

1662

2570

2861

1667

2861

1667

1666

2572

2862

1671

2862

1671

1670

2574

2863

1675

2863

1675

1674

2576

2944

1999

2944

1999

1998

2738

2945

2003

2945

2003

2002

2740

2946

2007

2946

2007

2006

2742

2947

2011

2947

2011

2010

2744

2948

2015

2948

2015

2014

2746

2949

2019

2949

2019

2018

2748

2950

2023

2950

2023

2022

2750

2951

2027

2951

2027

2026

2752

2952

2031

2952

2031

2030

2754

2953

2035

2953

2035

2034

2756

2954

2039

2954

2039

2038

2758

2955

2043

2955

2043

2042

2760

2956

2047

2956

2047

2046

2762

2957

2051

2957

2051

2050

2764

2958

2055

2958

2055

2054

2766

2959

2059

2959

2059

2058

2768

2960

2063

2960

2063

2062

2770

2961

2067

2961

2067

2066

2772

2962

2071

OptiStruct 13.0 Reference Guide 1451


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2070
1634
2074
1635
2078
1636
2082
1637
2086
1638
2090
1639
2094
1640
2098
1641
2102
1642
2106
1643
2110
1644
2114
1645
2118
1646
2122
1647
2126
1648
2130
1649
2134
1650
2138
1651
2142
1652
2146
1653
2150
1654
2154
1655
2158
1656
2162
1657
2495
1658
2497
1659
2499
1660
2501
1661
2503
1662
2505
1663
2507
1664
2509
1665
2511
1666
2513
1667
2515

2774
2
2776
2
2778
2
2780
2
2782
2
2784
2
2786
2
2788
2
2790
2
2792
2
2794
2
2796
2
2798
2
2800
2
2802
2
2804
2
2806
2
2808
2
2810
2
2812
2
2814
2
2816
2
2818
2
2820
2
2987
2
2989
2
2991
2
2993
2
2995
2
2997
2
2999
2
3001
2
3003
2
3005
2
3007

2962

2071

2070

2774

2963

2075

2963

2075

2074

2776

2964

2079

2964

2079

2078

2778

2965

2083

2965

2083

2082

2780

2966

2087

2966

2087

2086

2782

2967

2091

2967

2091

2090

2784

2968

2095

2968

2095

2094

2786

2969

2099

2969

2099

2098

2788

2970

2103

2970

2103

2102

2790

2971

2107

2971

2107

2106

2792

2972

2111

2972

2111

2110

2794

2973

2115

2973

2115

2114

2796

2974

2119

2974

2119

2118

2798

2975

2123

2975

2123

2122

2800

2976

2127

2976

2127

2126

2802

2977

2131

2977

2131

2130

2804

2978

2135

2978

2135

2134

2806

2979

2139

2979

2139

2138

2808

2980

2143

2980

2143

2142

2810

2981

2147

2981

2147

2146

2812

2982

2151

2982

2151

2150

2814

2983

2155

2983

2155

2154

2816

2984

2159

2984

2159

2158

2818

2985

2163

28

33

31

27

2986

2494

2986

2494

2495

2987

2988

2496

2988

2496

2497

2989

2990

2498

2990

2498

2499

2991

2992

2500

2992

2500

2501

2993

2994

2502

2994

2502

2503

2995

2996

2504

2996

2504

2505

2997

2998

2506

2998

2506

2507

2999

3000

2508

3000

2508

2509

3001

3002

2510

3002

2510

2511

3003

3004

2512

3004

2512

2513

3005

3006

2514

1452 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1668
2517
1669
2519
1670
2521
1671
2523
1672
2525
1673
2527
1674
2529
1675
2531
1676
2533
1677
2535
1678
2537
1679
2539
1680
2541
1681
2543
1682
2545
1683
2547
1684
2549
1685
2551
1686
2553
1687
2555
1688
2557
1689
2559
1690
2561
1691
2563
1692
2565
1693
2567
1694
2569
1695
2571
1696
2573
1697
2575
1698
2577
1779
2739
1780
2741
1781
2743
1782

Altair Engineering

2
3009
2
3011
2
3013
2
3015
2
3017
2
3019
2
3021
2
3023
2
3025
2
3027
2
3029
2
3031
2
3033
2
3035
2
3037
2
3039
2
3041
2
3043
2
3045
2
3047
2
3049
2
3051
2
3053
2
3055
2
3057
2
3059
2
3061
2
3063
2
3065
2
3067
2
3069
2
3231
2
3233
2
3235
2

3006

2514

2515

3007

3008

2516

3008

2516

2517

3009

3010

2518

3010

2518

2519

3011

3012

2520

3012

2520

2521

3013

3014

2522

3014

2522

2523

3015

3016

2524

3016

2524

2525

3017

3018

2526

3018

2526

2527

3019

3020

2528

3020

2528

2529

3021

3022

2530

3022

2530

2531

3023

3024

2532

3024

2532

2533

3025

3026

2534

3026

2534

2535

3027

3028

2536

3028

2536

2537

3029

3030

2538

3030

2538

2539

3031

3032

2540

3032

2540

2541

3033

3034

2542

3034

2542

2543

3035

3036

2544

3036

2544

2545

3037

3038

2546

3038

2546

2547

3039

3040

2548

3040

2548

2549

3041

3042

2550

3042

2550

2551

3043

3044

2552

3044

2552

2553

3045

3046

2554

3046

2554

2555

3047

3048

2556

3048

2556

2557

3049

3050

2558

3050

2558

2559

3051

3052

2560

3052

2560

2561

3053

3054

2562

3054

2562

2563

3055

3056

2564

3056

2564

2565

3057

3058

2566

3058

2566

2567

3059

3060

2568

3060

2568

2569

3061

3062

2570

3062

2570

2571

3063

3064

2572

3064

2572

2573

3065

3066

2574

3066

2574

2575

3067

3068

2576

3068

2576

2577

3069

3230

2738

3230

2738

2739

3231

3232

2740

3232

2740

2741

3233

3234

2742

3234

2742

2743

3235

3236

2744

OptiStruct 13.0 Reference Guide 1453


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2745
1783
2747
1784
2749
1785
2751
1786
2753
1787
2755
1788
2757
1789
2759
1790
2761
1791
2763
1792
2765
1793
2767
1794
2769
1795
2771
1796
2773
1797
2775
1798
2777
1799
2779
1800
2781
1801
2783
1802
2785
1803
2787
1804
2789
1805
2791
1806
2793
1807
2795
1808
2797
1809
2799
1810
2801
1811
2803
1812
2805
1813
2807
1814
2809
1815
2811
1816
2813

3237
2
3239
2
3241
2
3243
2
3245
2
3247
2
3249
2
3251
2
3253
2
3255
2
3257
2
3259
2
3261
2
3263
2
3265
2
3267
2
3269
2
3271
2
3273
2
3275
2
3277
2
3279
2
3281
2
3283
2
3285
2
3287
2
3289
2
3291
2
3293
2
3295
2
3297
2
3299
2
3301
2
3303
2
3305

3236

2744

2745

3237

3238

2746

3238

2746

2747

3239

3240

2748

3240

2748

2749

3241

3242

2750

3242

2750

2751

3243

3244

2752

3244

2752

2753

3245

3246

2754

3246

2754

2755

3247

3248

2756

3248

2756

2757

3249

3250

2758

3250

2758

2759

3251

3252

2760

3252

2760

2761

3253

3254

2762

3254

2762

2763

3255

3256

2764

3256

2764

2765

3257

3258

2766

3258

2766

2767

3259

3260

2768

3260

2768

2769

3261

3262

2770

3262

2770

2771

3263

3264

2772

3264

2772

2773

3265

3266

2774

3266

2774

2775

3267

3268

2776

3268

2776

2777

3269

3270

2778

3270

2778

2779

3271

3272

2780

3272

2780

2781

3273

3274

2782

3274

2782

2783

3275

3276

2784

3276

2784

2785

3277

3278

2786

3278

2786

2787

3279

3280

2788

3280

2788

2789

3281

3282

2790

3282

2790

2791

3283

3284

2792

3284

2792

2793

3285

3286

2794

3286

2794

2795

3287

3288

2796

3288

2796

2797

3289

3290

2798

3290

2798

2799

3291

3292

2800

3292

2800

2801

3293

3294

2802

3294

2802

2803

3295

3296

2804

3296

2804

2805

3297

3298

2806

3298

2806

2807

3299

3300

2808

3300

2808

2809

3301

3302

2810

3302

2810

2811

3303

3304

2812

1454 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1817
2815
1818
2817
1819
2819
1820
2821
1821
2494
1822
2496
1823
2498
1824
2500
1825
2502
1826
2504
1827
2506
1828
2508
1829
2510
1830
2512
1831
2514
1832
2516
1833
2518
1834
2520
1835
2522
1836
2524
1837
2526
1838
2528
1839
2530
1840
2532
1841
2534
1842
2536
1843
2538
1844
2540
1845
2542
1846
2544
1847
2546
1848
2548
1849
2550
1850
2552
1851

Altair Engineering

2
3307
2
3309
2
3311
2
3313
2
2986
2
2988
2
2990
2
2992
2
2994
2
2996
2
2998
2
3000
2
3002
2
3004
2
3006
2
3008
2
3010
2
3012
2
3014
2
3016
2
3018
2
3020
2
3022
2
3024
2
3026
2
3028
2
3030
2
3032
2
3034
2
3036
2
3038
2
3040
2
3042
2
3044
2

3304

2812

2813

3305

3306

2814

3306

2814

2815

3307

3308

2816

3308

2816

2817

3309

3310

2818

3310

2818

2819

3311

3312

2820

29

30

33

28

3314

2822

3314

2822

2494

2986

3315

2823

3315

2823

2496

2988

3316

2824

3316

2824

2498

2990

3317

2825

3317

2825

2500

2992

3318

2826

3318

2826

2502

2994

3319

2827

3319

2827

2504

2996

3320

2828

3320

2828

2506

2998

3321

2829

3321

2829

2508

3000

3322

2830

3322

2830

2510

3002

3323

2831

3323

2831

2512

3004

3324

2832

3324

2832

2514

3006

3325

2833

3325

2833

2516

3008

3326

2834

3326

2834

2518

3010

3327

2835

3327

2835

2520

3012

3328

2836

3328

2836

2522

3014

3329

2837

3329

2837

2524

3016

3330

2838

3330

2838

2526

3018

3331

2839

3331

2839

2528

3020

3332

2840

3332

2840

2530

3022

3333

2841

3333

2841

2532

3024

3334

2842

3334

2842

2534

3026

3335

2843

3335

2843

2536

3028

3336

2844

3336

2844

2538

3030

3337

2845

3337

2845

2540

3032

3338

2846

3338

2846

2542

3034

3339

2847

3339

2847

2544

3036

3340

2848

3340

2848

2546

3038

3341

2849

3341

2849

2548

3040

3342

2850

3342

2850

2550

3042

3343

2851

3343

2851

2552

3044

3344

2852

OptiStruct 13.0 Reference Guide 1455


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

2554
1852
2556
1853
2558
1854
2560
1855
2562
1856
2564
1857
2566
1858
2568
1859
2570
1860
2572
1861
2574
1862
2576
1943
2738
1944
2740
1945
2742
1946
2744
1947
2746
1948
2748
1949
2750
1950
2752
1951
2754
1952
2756
1953
2758
1954
2760
1955
2762
1956
2764
1957
2766
1958
2768
1959
2770
1960
2772
1961
2774
1962
2776
1963
2778
1964
2780
1965
2782

3046
2
3048
2
3050
2
3052
2
3054
2
3056
2
3058
2
3060
2
3062
2
3064
2
3066
2
3068
2
3230
2
3232
2
3234
2
3236
2
3238
2
3240
2
3242
2
3244
2
3246
2
3248
2
3250
2
3252
2
3254
2
3256
2
3258
2
3260
2
3262
2
3264
2
3266
2
3268
2
3270
2
3272
2
3274

3344

2852

2554

3046

3345

2853

3345

2853

2556

3048

3346

2854

3346

2854

2558

3050

3347

2855

3347

2855

2560

3052

3348

2856

3348

2856

2562

3054

3349

2857

3349

2857

2564

3056

3350

2858

3350

2858

2566

3058

3351

2859

3351

2859

2568

3060

3352

2860

3352

2860

2570

3062

3353

2861

3353

2861

2572

3064

3354

2862

3354

2862

2574

3066

3355

2863

3355

2863

2576

3068

3436

2944

3436

2944

2738

3230

3437

2945

3437

2945

2740

3232

3438

2946

3438

2946

2742

3234

3439

2947

3439

2947

2744

3236

3440

2948

3440

2948

2746

3238

3441

2949

3441

2949

2748

3240

3442

2950

3442

2950

2750

3242

3443

2951

3443

2951

2752

3244

3444

2952

3444

2952

2754

3246

3445

2953

3445

2953

2756

3248

3446

2954

3446

2954

2758

3250

3447

2955

3447

2955

2760

3252

3448

2956

3448

2956

2762

3254

3449

2957

3449

2957

2764

3256

3450

2958

3450

2958

2766

3258

3451

2959

3451

2959

2768

3260

3452

2960

3452

2960

2770

3262

3453

2961

3453

2961

2772

3264

3454

2962

3454

2962

2774

3266

3455

2963

3455

2963

2776

3268

3456

2964

3456

2964

2778

3270

3457

2965

3457

2965

2780

3272

3458

2966

1456 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

1966
2784
1967
2786
1968
2788
1969
2790
1970
2792
1971
2794
1972
2796
1973
2798
1974
2800
1975
2802
1976
2804
1977
2806
1978
2808
1979
2810
1980
2812
1981
2814
1982
2816
1983
2818
1984
2820
1985
690
1986
692
1987
694
1988
696
1989
698
1990
700
1991
702
1992
704
1993
706
1994
708
1995
710
1996
712
1997
714
1998
716
1999
718
2000

Altair Engineering

2
3276
2
3278
2
3280
2
3282
2
3284
2
3286
2
3288
2
3290
2
3292
2
3294
2
3296
2
3298
2
3300
2
3302
2
3304
2
3306
2
3308
2
3310
2
3312
2
3479
2
3481
2
3483
2
3485
2
3487
2
3489
2
3491
2
3493
2
3495
2
3497
2
3499
2
3501
2
3503
2
3505
2
3507
2

3458

2966

2782

3274

3459

2967

3459

2967

2784

3276

3460

2968

3460

2968

2786

3278

3461

2969

3461

2969

2788

3280

3462

2970

3462

2970

2790

3282

3463

2971

3463

2971

2792

3284

3464

2972

3464

2972

2794

3286

3465

2973

3465

2973

2796

3288

3466

2974

3466

2974

2798

3290

3467

2975

3467

2975

2800

3292

3468

2976

3468

2976

2802

3294

3469

2977

3469

2977

2804

3296

3470

2978

3470

2978

2806

3298

3471

2979

3471

2979

2808

3300

3472

2980

3472

2980

2810

3302

3473

2981

3473

2981

2812

3304

3474

2982

3474

2982

2814

3306

3475

2983

3475

2983

2816

3308

3476

2984

3476

2984

2818

3310

3477

2985

32

10

24

3478

34

3478

34

690

3479

3480

38

3480

38

692

3481

3482

42

3482

42

694

3483

3484

46

3484

46

696

3485

3486

50

3486

50

698

3487

3488

54

3488

54

700

3489

3490

58

3490

58

702

3491

3492

62

3492

62

704

3493

3494

66

3494

66

706

3495

3496

70

3496

70

708

3497

3498

74

3498

74

710

3499

3500

78

3500

78

712

3501

3502

82

3502

82

714

3503

3504

86

3504

86

716

3505

3506

90

3506

90

718

3507

3508

94

OptiStruct 13.0 Reference Guide 1457


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

720
2001
722
2002
724
2003
726
2004
728
2005
730
2006
732
2007
734
2008
736
2009
738
2010
740
2011
742
2012
744
2013
746
2014
748
2015
750
2016
752
2017
754
2018
756
2019
758
2020
760
2021
762
2022
764
2023
766
2024
768
2025
770
2026
772
2107
934
2108
936
2109
938
2110
940
2111
942
2112
944
2113
946
2114
948

3509
2
3511
2
3513
2
3515
2
3517
2
3519
2
3521
2
3523
2
3525
2
3527
2
3529
2
3531
2
3533
2
3535
2
3537
2
3539
2
3541
2
3543
2
3545
2
3547
2
3549
2
3551
2
3553
2
3555
2
3557
2
3559
2
3561
2
3723
2
3725
2
3727
2
3729
2
3731
2
3733
2
3735
2
3737

3508

94

720

3509

3510

98

3510

98

722

3511

3512

102

3512

102

724

3513

3514

106

3514

106

726

3515

3516

110

3516

110

728

3517

3518

114

3518

114

730

3519

3520

118

3520

118

732

3521

3522

122

3522

122

734

3523

3524

126

3524

126

736

3525

3526

130

3526

130

738

3527

3528

134

3528

134

740

3529

3530

138

3530

138

742

3531

3532

142

3532

142

744

3533

3534

146

3534

146

746

3535

3536

150

3536

150

748

3537

3538

154

3538

154

750

3539

3540

158

3540

158

752

3541

3542

162

3542

162

754

3543

3544

166

3544

166

756

3545

3546

170

3546

170

758

3547

3548

174

3548

174

760

3549

3550

178

3550

178

762

3551

3552

182

3552

182

764

3553

3554

186

3554

186

766

3555

3556

190

3556

190

768

3557

3558

194

3558

194

770

3559

3560

198

3560

198

772

3561

3722

522

3722

522

934

3723

3724

526

3724

526

936

3725

3726

530

3726

530

938

3727

3728

534

3728

534

940

3729

3730

538

3730

538

942

3731

3732

542

3732

542

944

3733

3734

546

3734

546

946

3735

3736

550

1458 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

2115
950
2116
952
2117
954
2118
956
2119
958
2120
960
2121
962
2122
964
2123
966
2124
968
2125
970
2126
972
2127
974
2128
976
2129
978
2130
980
2131
982
2132
984
2133
986
2134
988
2135
990
2136
992
2137
994
2138
996
2139
998
2140
1000
2141
1002
2142
1004
2143
1006
2144
1008
2145
1010
2146
1012
2147
1014
2148
1016
2149

Altair Engineering

2
3739
2
3741
2
3743
2
3745
2
3747
2
3749
2
3751
2
3753
2
3755
2
3757
2
3759
2
3761
2
3763
2
3765
2
3767
2
3769
2
3771
2
3773
2
3775
2
3777
2
3779
2
3781
2
3783
2
3785
2
3787
2
3789
2
3791
2
3793
2
3795
2
3797
2
3799
2
3801
2
3803
2
3805
2

3736

550

948

3737

3738

554

3738

554

950

3739

3740

558

3740

558

952

3741

3742

562

3742

562

954

3743

3744

566

3744

566

956

3745

3746

570

3746

570

958

3747

3748

574

3748

574

960

3749

3750

578

3750

578

962

3751

3752

582

3752

582

964

3753

3754

586

3754

586

966

3755

3756

590

3756

590

968

3757

3758

594

3758

594

970

3759

3760

598

3760

598

972

3761

3762

602

3762

602

974

3763

3764

606

3764

606

976

3765

3766

610

3766

610

978

3767

3768

614

3768

614

980

3769

3770

618

3770

618

982

3771

3772

622

3772

622

984

3773

3774

626

3774

626

986

3775

3776

630

3776

630

988

3777

3778

634

3778

634

990

3779

3780

638

3780

638

992

3781

3782

642

3782

642

994

3783

3784

646

3784

646

996

3785

3786

650

3786

650

998

3787

3788

654

3788

654

1000

3789

3790

658

3790

658

1002

3791

3792

662

3792

662

1004

3793

3794

666

3794

666

1006

3795

3796

670

3796

670

1008

3797

3798

674

3798

674

1010

3799

3800

678

3800

678

1012

3801

3802

682

3802

682

1014

3803

3804

686

31

11

10

32

2495

35

OptiStruct 13.0 Reference Guide 1459


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

34
2150
38
2151
42
2152
46
2153
50
2154
54
2155
58
2156
62
2157
66
2158
70
2159
74
2160
78
2161
82
2162
86
2163
90
2164
94
2165
98
2166
102
2167
106
2168
110
2169
114
2170
118
2171
122
2172
126
2173
130
2174
134
2175
138
2176
142
2177
146
2178
150
2179
154
2180
158
2181
162
2182
166
2183
170

3478
2
3480
2
3482
2
3484
2
3486
2
3488
2
3490
2
3492
2
3494
2
3496
2
3498
2
3500
2
3502
2
3504
2
3506
2
3508
2
3510
2
3512
2
3514
2
3516
2
3518
2
3520
2
3522
2
3524
2
3526
2
3528
2
3530
2
3532
2
3534
2
3536
2
3538
2
3540
2
3542
2
3544
2
3546

2495

35

34

3478

2497

39

2497

39

38

3480

2499

43

2499

43

42

3482

2501

47

2501

47

46

3484

2503

51

2503

51

50

3486

2505

55

2505

55

54

3488

2507

59

2507

59

58

3490

2509

63

2509

63

62

3492

2511

67

2511

67

66

3494

2513

71

2513

71

70

3496

2515

75

2515

75

74

3498

2517

79

2517

79

78

3500

2519

83

2519

83

82

3502

2521

87

2521

87

86

3504

2523

91

2523

91

90

3506

2525

95

2525

95

94

3508

2527

99

2527

99

98

3510

2529

103

2529

103

102

3512

2531

107

2531

107

106

3514

2533

111

2533

111

110

3516

2535

115

2535

115

114

3518

2537

119

2537

119

118

3520

2539

123

2539

123

122

3522

2541

127

2541

127

126

3524

2543

131

2543

131

130

3526

2545

135

2545

135

134

3528

2547

139

2547

139

138

3530

2549

143

2549

143

142

3532

2551

147

2551

147

146

3534

2553

151

2553

151

150

3536

2555

155

2555

155

154

3538

2557

159

2557

159

158

3540

2559

163

2559

163

162

3542

2561

167

2561

167

166

3544

2563

171

1460 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

2184
174
2185
178
2186
182
2187
186
2188
190
2189
194
2190
198
2271
522
2272
526
2273
530
2274
534
2275
538
2276
542
2277
546
2278
550
2279
554
2280
558
2281
562
2282
566
2283
570
2284
574
2285
578
2286
582
2287
586
2288
590
2289
594
2290
598
2291
602
2292
606
2293
610
2294
614
2295
618
2296
622
2297
626
2298

Altair Engineering

2
3548
2
3550
2
3552
2
3554
2
3556
2
3558
2
3560
2
3722
2
3724
2
3726
2
3728
2
3730
2
3732
2
3734
2
3736
2
3738
2
3740
2
3742
2
3744
2
3746
2
3748
2
3750
2
3752
2
3754
2
3756
2
3758
2
3760
2
3762
2
3764
2
3766
2
3768
2
3770
2
3772
2
3774
2

2563

171

170

3546

2565

175

2565

175

174

3548

2567

179

2567

179

178

3550

2569

183

2569

183

182

3552

2571

187

2571

187

186

3554

2573

191

2573

191

190

3556

2575

195

2575

195

194

3558

2577

199

2577

199

198

3560

2739

523

2739

523

522

3722

2741

527

2741

527

526

3724

2743

531

2743

531

530

3726

2745

535

2745

535

534

3728

2747

539

2747

539

538

3730

2749

543

2749

543

542

3732

2751

547

2751

547

546

3734

2753

551

2753

551

550

3736

2755

555

2755

555

554

3738

2757

559

2757

559

558

3740

2759

563

2759

563

562

3742

2761

567

2761

567

566

3744

2763

571

2763

571

570

3746

2765

575

2765

575

574

3748

2767

579

2767

579

578

3750

2769

583

2769

583

582

3752

2771

587

2771

587

586

3754

2773

591

2773

591

590

3756

2775

595

2775

595

594

3758

2777

599

2777

599

598

3760

2779

603

2779

603

602

3762

2781

607

2781

607

606

3764

2783

611

2783

611

610

3766

2785

615

2785

615

614

3768

2787

619

2787

619

618

3770

2789

623

2789

623

622

3772

2791

627

2791

627

626

3774

2793

631

OptiStruct 13.0 Reference Guide 1461


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

630
2299
634
2300
638
2301
642
2302
646
2303
650
2304
654
2305
658
2306
662
2307
666
2308
670
2309
674
2310
678
2311
682
2312
686
2313
3479
2314
3481
2315
3483
2316
3485
2317
3487
2318
3489
2319
3491
2320
3493
2321
3495
2322
3497
2323
3499
2324
3501
2325
3503
2326
3505
2327
3507
2328
3509
2329
3511
2330
3513
2331
3515
2332
3517

3776
2
3778
2
3780
2
3782
2
3784
2
3786
2
3788
2
3790
2
3792
2
3794
2
3796
2
3798
2
3800
2
3802
2
3804
2
3807
2
3809
2
3811
2
3813
2
3815
2
3817
2
3819
2
3821
2
3823
2
3825
2
3827
2
3829
2
3831
2
3833
2
3835
2
3837
2
3839
2
3841
2
3843
2
3845

2793

631

630

3776

2795

635

2795

635

634

3778

2797

639

2797

639

638

3780

2799

643

2799

643

642

3782

2801

647

2801

647

646

3784

2803

651

2803

651

650

3786

2805

655

2805

655

654

3788

2807

659

2807

659

658

3790

2809

663

2809

663

662

3792

2811

667

2811

667

666

3794

2813

671

2813

671

670

3796

2815

675

2815

675

674

3798

2817

679

2817

679

678

3800

2819

683

2819

683

682

3802

2821

687

26

32

24

25

3806

3478

3806

3478

3479

3807

3808

3480

3808

3480

3481

3809

3810

3482

3810

3482

3483

3811

3812

3484

3812

3484

3485

3813

3814

3486

3814

3486

3487

3815

3816

3488

3816

3488

3489

3817

3818

3490

3818

3490

3491

3819

3820

3492

3820

3492

3493

3821

3822

3494

3822

3494

3495

3823

3824

3496

3824

3496

3497

3825

3826

3498

3826

3498

3499

3827

3828

3500

3828

3500

3501

3829

3830

3502

3830

3502

3503

3831

3832

3504

3832

3504

3505

3833

3834

3506

3834

3506

3507

3835

3836

3508

3836

3508

3509

3837

3838

3510

3838

3510

3511

3839

3840

3512

3840

3512

3513

3841

3842

3514

3842

3514

3515

3843

3844

3516

1462 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

2333
3519
2334
3521
2335
3523
2336
3525
2337
3527
2338
3529
2339
3531
2340
3533
2341
3535
2342
3537
2343
3539
2344
3541
2345
3543
2346
3545
2347
3547
2348
3549
2349
3551
2350
3553
2351
3555
2352
3557
2353
3559
2354
3561
2435
3723
2436
3725
2437
3727
2438
3729
2439
3731
2440
3733
2441
3735
2442
3737
2443
3739
2444
3741
2445
3743
2446
3745
2447

Altair Engineering

2
3847
2
3849
2
3851
2
3853
2
3855
2
3857
2
3859
2
3861
2
3863
2
3865
2
3867
2
3869
2
3871
2
3873
2
3875
2
3877
2
3879
2
3881
2
3883
2
3885
2
3887
2
3889
2
4051
2
4053
2
4055
2
4057
2
4059
2
4061
2
4063
2
4065
2
4067
2
4069
2
4071
2
4073
2

3844

3516

3517

3845

3846

3518

3846

3518

3519

3847

3848

3520

3848

3520

3521

3849

3850

3522

3850

3522

3523

3851

3852

3524

3852

3524

3525

3853

3854

3526

3854

3526

3527

3855

3856

3528

3856

3528

3529

3857

3858

3530

3858

3530

3531

3859

3860

3532

3860

3532

3533

3861

3862

3534

3862

3534

3535

3863

3864

3536

3864

3536

3537

3865

3866

3538

3866

3538

3539

3867

3868

3540

3868

3540

3541

3869

3870

3542

3870

3542

3543

3871

3872

3544

3872

3544

3545

3873

3874

3546

3874

3546

3547

3875

3876

3548

3876

3548

3549

3877

3878

3550

3878

3550

3551

3879

3880

3552

3880

3552

3553

3881

3882

3554

3882

3554

3555

3883

3884

3556

3884

3556

3557

3885

3886

3558

3886

3558

3559

3887

3888

3560

3888

3560

3561

3889

4050

3722

4050

3722

3723

4051

4052

3724

4052

3724

3725

4053

4054

3726

4054

3726

3727

4055

4056

3728

4056

3728

3729

4057

4058

3730

4058

3730

3731

4059

4060

3732

4060

3732

3733

4061

4062

3734

4062

3734

3735

4063

4064

3736

4064

3736

3737

4065

4066

3738

4066

3738

3739

4067

4068

3740

4068

3740

3741

4069

4070

3742

4070

3742

3743

4071

4072

3744

4072

3744

3745

4073

4074

3746

OptiStruct 13.0 Reference Guide 1463


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

3747
2448
3749
2449
3751
2450
3753
2451
3755
2452
3757
2453
3759
2454
3761
2455
3763
2456
3765
2457
3767
2458
3769
2459
3771
2460
3773
2461
3775
2462
3777
2463
3779
2464
3781
2465
3783
2466
3785
2467
3787
2468
3789
2469
3791
2470
3793
2471
3795
2472
3797
2473
3799
2474
3801
2475
3803
2476
3805
2477
3478
2478
3480
2479
3482
2480
3484
2481
3486

4075
2
4077
2
4079
2
4081
2
4083
2
4085
2
4087
2
4089
2
4091
2
4093
2
4095
2
4097
2
4099
2
4101
2
4103
2
4105
2
4107
2
4109
2
4111
2
4113
2
4115
2
4117
2
4119
2
4121
2
4123
2
4125
2
4127
2
4129
2
4131
2
4133
2
3806
2
3808
2
3810
2
3812
2
3814

4074

3746

3747

4075

4076

3748

4076

3748

3749

4077

4078

3750

4078

3750

3751

4079

4080

3752

4080

3752

3753

4081

4082

3754

4082

3754

3755

4083

4084

3756

4084

3756

3757

4085

4086

3758

4086

3758

3759

4087

4088

3760

4088

3760

3761

4089

4090

3762

4090

3762

3763

4091

4092

3764

4092

3764

3765

4093

4094

3766

4094

3766

3767

4095

4096

3768

4096

3768

3769

4097

4098

3770

4098

3770

3771

4099

4100

3772

4100

3772

3773

4101

4102

3774

4102

3774

3775

4103

4104

3776

4104

3776

3777

4105

4106

3778

4106

3778

3779

4107

4108

3780

4108

3780

3781

4109

4110

3782

4110

3782

3783

4111

4112

3784

4112

3784

3785

4113

4114

3786

4114

3786

3787

4115

4116

3788

4116

3788

3789

4117

4118

3790

4118

3790

3791

4119

4120

3792

4120

3792

3793

4121

4122

3794

4122

3794

3795

4123

4124

3796

4124

3796

3797

4125

4126

3798

4126

3798

3799

4127

4128

3800

4128

3800

3801

4129

4130

3802

4130

3802

3803

4131

4132

3804

27

31

32

26

2987

2495

2987

2495

3478

3806

2989

2497

2989

2497

3480

3808

2991

2499

2991

2499

3482

3810

2993

2501

2993

2501

3484

3812

2995

2503

1464 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

2482
3488
2483
3490
2484
3492
2485
3494
2486
3496
2487
3498
2488
3500
2489
3502
2490
3504
2491
3506
2492
3508
2493
3510
2494
3512
2495
3514
2496
3516
2497
3518
2498
3520
2499
3522
2500
3524
2501
3526
2502
3528
2503
3530
2504
3532
2505
3534
2506
3536
2507
3538
2508
3540
2509
3542
2510
3544
2511
3546
2512
3548
2513
3550
2514
3552
2515
3554
2516

Altair Engineering

2
3816
2
3818
2
3820
2
3822
2
3824
2
3826
2
3828
2
3830
2
3832
2
3834
2
3836
2
3838
2
3840
2
3842
2
3844
2
3846
2
3848
2
3850
2
3852
2
3854
2
3856
2
3858
2
3860
2
3862
2
3864
2
3866
2
3868
2
3870
2
3872
2
3874
2
3876
2
3878
2
3880
2
3882
2

2995

2503

3486

3814

2997

2505

2997

2505

3488

3816

2999

2507

2999

2507

3490

3818

3001

2509

3001

2509

3492

3820

3003

2511

3003

2511

3494

3822

3005

2513

3005

2513

3496

3824

3007

2515

3007

2515

3498

3826

3009

2517

3009

2517

3500

3828

3011

2519

3011

2519

3502

3830

3013

2521

3013

2521

3504

3832

3015

2523

3015

2523

3506

3834

3017

2525

3017

2525

3508

3836

3019

2527

3019

2527

3510

3838

3021

2529

3021

2529

3512

3840

3023

2531

3023

2531

3514

3842

3025

2533

3025

2533

3516

3844

3027

2535

3027

2535

3518

3846

3029

2537

3029

2537

3520

3848

3031

2539

3031

2539

3522

3850

3033

2541

3033

2541

3524

3852

3035

2543

3035

2543

3526

3854

3037

2545

3037

2545

3528

3856

3039

2547

3039

2547

3530

3858

3041

2549

3041

2549

3532

3860

3043

2551

3043

2551

3534

3862

3045

2553

3045

2553

3536

3864

3047

2555

3047

2555

3538

3866

3049

2557

3049

2557

3540

3868

3051

2559

3051

2559

3542

3870

3053

2561

3053

2561

3544

3872

3055

2563

3055

2563

3546

3874

3057

2565

3057

2565

3548

3876

3059

2567

3059

2567

3550

3878

3061

2569

3061

2569

3552

3880

3063

2571

3063

2571

3554

3882

3065

2573

OptiStruct 13.0 Reference Guide 1465


Proprietary Information of Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

3556
2517
3558
2518
3560
2599
3722
2600
3724
2601
3726
2602
3728
2603
3730
2604
3732
2605
3734
2606
3736
2607
3738
2608
3740
2609
3742
2610
3744
2611
3746
2612
3748
2613
3750
2614
3752
2615
3754
2616
3756
2617
3758
2618
3760
2619
3762
2620
3764
2621
3766
2622
3768
2623
3770
2624
3772
2625
3774
2626
3776
2627
3778
2628
3780
2629
3782
2630
3784

3884
2
3886
2
3888
2
4050
2
4052
2
4054
2
4056
2
4058
2
4060
2
4062
2
4064
2
4066
2
4068
2
4070
2
4072
2
4074
2
4076
2
4078
2
4080
2
4082
2
4084
2
4086
2
4088
2
4090
2
4092
2
4094
2
4096
2
4098
2
4100
2
4102
2
4104
2
4106
2
4108
2
4110
2
4112

3065

2573

3556

3884

3067

2575

3067

2575

3558

3886

3069

2577

3069

2577

3560

3888

3231

2739

3231

2739

3722

4050

3233

2741

3233

2741

3724

4052

3235

2743

3235

2743

3726

4054

3237

2745

3237

2745

3728

4056

3239

2747

3239

2747

3730

4058

3241

2749

3241

2749

3732

4060

3243

2751

3243

2751

3734

4062

3245

2753

3245

2753

3736

4064

3247

2755

3247

2755

3738

4066

3249

2757

3249

2757

3740

4068

3251

2759

3251

2759

3742

4070

3253

2761

3253

2761

3744

4072

3255

2763

3255

2763

3746

4074

3257

2765

3257

2765

3748

4076

3259

2767

3259

2767

3750

4078

3261

2769

3261

2769

3752

4080

3263

2771

3263

2771

3754

4082

3265

2773

3265

2773

3756

4084

3267

2775

3267

2775

3758

4086

3269

2777

3269

2777

3760

4088

3271

2779

3271

2779

3762

4090

3273

2781

3273

2781

3764

4092

3275

2783

3275

2783

3766

4094

3277

2785

3277

2785

3768

4096

3279

2787

3279

2787

3770

4098

3281

2789

3281

2789

3772

4100

3283

2791

3283

2791

3774

4102

3285

2793

3285

2793

3776

4104

3287

2795

3287

2795

3778

4106

3289

2797

3289

2797

3780

4108

3291

2799

3291

2799

3782

4110

3293

2801

1466 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
2631
2
3293
2801
3784
4112
3295
2803
+
3786
4114
CHEXA
2632
2
3295
2803
3786
4114
3297
2805
+
3788
4116
CHEXA
2633
2
3297
2805
3788
4116
3299
2807
+
3790
4118
CHEXA
2634
2
3299
2807
3790
4118
3301
2809
+
3792
4120
CHEXA
2635
2
3301
2809
3792
4120
3303
2811
+
3794
4122
CHEXA
2636
2
3303
2811
3794
4122
3305
2813
+
3796
4124
CHEXA
2637
2
3305
2813
3796
4124
3307
2815
+
3798
4126
CHEXA
2638
2
3307
2815
3798
4126
3309
2817
+
3800
4128
CHEXA
2639
2
3309
2817
3800
4128
3311
2819
+
3802
4130
CHEXA
2640
2
3311
2819
3802
4130
3313
2821
+
3804
4132
$
$HMMOVE
2
$
17THRU
58
139THRU
222
303THRU
386
$
467THRU
550
631THRU
714
795THRU
878
$
959THRU
1042
1123THRU
1206
1287THRU
1370
$
1451THRU
1534
1615THRU
1698
1779THRU
1862
$
1943THRU
2026
2107THRU
2190
2271THRU
2354
$
2435THRU
2518
2599THRU
2640
$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name and color information for generic components
$
$$------------------------------------------------------------------------------$
$HMNAME COMP
2"Air"
2 "Air" 5
$HWCOLOR COMP
2
5
$
$HMNAME COMP
5"Piston"
$HWCOLOR COMP
5
8
$
$HMNAME COMP
6"absorber"
$HWCOLOR COMP
6
3
$
$
$HMDPRP
$
17THRU
58
139THRU
222
303THRU
386
$
467THRU
550
631THRU
714
795THRU
878
$
959THRU
1042
1123THRU
1206
1287THRU
1370
$
1451THRU
1534
1615THRU
1698
1779THRU
1862
$
1943THRU
2026
2107THRU
2190
2271THRU
2354
$
2435THRU
2518
2599THRU
2640
5627
5629
6116
$
6122
6125
6520THRU
6521
6523
6528
6954
7220
$
7647
7652
7945
7948
7955
$
$
$$
$$ PSHELL Data
$$
$
$
$
$
$
$
$
$HMNAME PROP
$HWCOLOR PROP
PSHELL
1
$$

Altair Engineering

20.1

1"tube" 4
1
52
2

0.0

OptiStruct 13.0 Reference Guide 1467


Proprietary Information of Altair Engineering

$$ PSOLID Data
$$
$HMNAME PROP
2"Air" 5
$HWCOLOR PROP
2
4
PSOLID
2
1
PFLUID
$$
$$ MAT1 Data
$$
$HMNAME MAT
2"alum" "MAT1"
$HWCOLOR MAT
2
3
MAT1
21.0+7
0.3
0.000254
$$
$$ MAT10 Data
$HMNAME MAT
1"Air" "MAT10"
$HWCOLOR MAT
1
3
MAT10
1
1.21-7 13000.0
$$
$$------------------------------------------------------------------------------$
$$ HyperMesh Commands for loadcollectors name and color information $
$$------------------------------------------------------------------------------$
$HMNAME LOADCOL
2"spc"
$HWCOLOR LOADCOL
2
6
$$
$HMNAME LOADCOL
8"Force"
$HWCOLOR LOADCOL
8
7
$$
$HMNAME LOADCOL
12"SPC"
$HWCOLOR LOADCOL
12
5
$$
$$
$$ FREQi cards
$$
$HMNAME LOADCOL
3"Freq"
$HWCOLOR LOADCOL
3
6
$FREQ1
3
0.0
5.0
600
FREQ
3480.
$
$$
$$ RLOAD1 cards
$$
$HMNAME LOADCOL
6"Rload"
$HWCOLOR LOADCOL
6
6
RLOAD1
6
8
7
0
VELO
$$
$$
$$ TABLED1 cards
$$
$HMNAME LOADCOL
7"Table"
$HWCOLOR LOADCOL
7
6
TABLED1
7 LINEAR LINEAR
+
0.0
1.0 3000.0
1.0ENDT
$$
$HMNAME LOADCOL
10"reactance"
$HWCOLOR LOADCOL
10
5
TABLED1
10 LINEAR LINEAR
+
0.0 0.00154 3000.0 0.00154ENDT
$$
$HMNAME LOADCOL
11"Impedance"
$HWCOLOR LOADCOL
11
5
TABLED1
11 LINEAR LINEAR
+
0.0
0.0 3000.0
0.0ENDT
$$
$$
$$ DLOAD cards
$$
$HMNAME LOADCOL
9"Dload"
$HWCOLOR LOADCOL
9
6
DLOAD
91.0
1.0
6
$$

1468 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$$ EIGRL cards
$$
$HMNAME LOADCOL
4"EigrlTube"
$HWCOLOR LOADCOL
4
6
EIGRL
4
5
MASS
$HMNAME LOADCOL
5"EigrlAir"
$HWCOLOR LOADCOL
5
6
EIGRL
5
30
MASS
$$
$$ SPC Data
$$
SPC1
12123456 6776
thru
6800
spcd
86776
3
1.0
spcd
86777
3
1.0
spcd
86778
3
1.0
spcd
86779
3
1.0
spcd
86780
3
1.0
spcd
86781
3
1.0
spcd
86782
3
1.0
spcd
86783
3
1.0
spcd
86784
3
1.0
spcd
86785
3
1.0
spcd
86786
3
1.0
spcd
86788
3
1.0
spcd
86789
3
1.0
spcd
86790
3
1.0
spcd
86791
3
1.0
spcd
86792
3
1.0
spcd
86793
3
1.0
spcd
86794
3
1.0
spcd
86795
3
1.0
spcd
86796
3
1.0
spcd
86797
3
1.0
spcd
86798
3
1.0
spcd
86799
3
1.0
spcd
86800
3
1.0
$
$ DAREA Data
$
$$
$$ DAREA Data
$$
DAREA
8
6798
3-15.0
$$
$$
CAABSF
7957
5
689
688
687
686
CAABSF
7960
5
1017
689
686
1016
CAABSF
7964
5
1345
1344
688
689
CAABSF
7969
5
1509
1345
689
1017
CAABSF
7972
5
2165
2164
2163
2162
CAABSF
7977
5
688
2165
2162
687
CAABSF
7978
5
4133
3805
3804
4132
CAABSF
7980
5
2493
2492
2164
2165
CAABSF
7984
5
1344
2493
2165
688
CAABSF
7985
5
2821
687
2162
2820
CAABSF
7988
5
2820
2162
2163
2985
CAABSF
7990
5
3313
2821
2820
3312
CAABSF
7994
5
3312
2820
2985
3477
CAABSF
7996
5
3805
1016
686
3804
CAABSF
7998
5
3804
686
687
2821
CAABSF
8003
5
4132
3804
2821
3313
PAABSF
5
11
10
ENDDATA
$$
$$------------------------------------------------------------------------------$$
$$
Data Definition for AutoDV
$$
$$------------------------------------------------------------------------------$$
$$
$$-----------------------------------------------------------------------------$$

Altair Engineering

OptiStruct 13.0 Reference Guide 1469


Proprietary Information of Altair Engineering

$$
Design Variables Card for Control Perturbations
$$
$$-----------------------------------------------------------------------------$$
$
$------------------------------------------------------------------------------$
$
Domain Element Definitions
$
$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$$
$$
Nodeset Definitions
$$
$$------------------------------------------------------------------------------$$
$$ Design domain node sets
$$
$$------------------------------------------------------------------------------$$
$$
Control Perturbation
$$
$$------------------------------------------------------------------------------$$
$$
$$
$$ CONTROL PERTURBATION Data
$$

ALTDOCTAG "0mjpRI@DXd^3_0ASnbi`;l;q6A23R@9_67hgW8R?OiZ]
Eq:PeN``A;WXh3ITgJeq5NZRd5jSHQK3X@:`a12;n4qD_I^RYMo"
ADI0.1.0 2011-02-11T20:16:20 0of1 OSQA
ENDDOCTAG

Comments
1.

PAABSF is referenced by a CAABSF entry only.

2.

If only one grid point is specified on the CAABSF entry, then the impedance Z(f) = ZR +
iZi is the total impedance at the point. If two grids are specified, then the impedance is
the impedance per unit length. If three or four points are specified, then the impedance
is the impedance per unit area. ZR(f) = TZREID(f) + B and Zi(f) = TZIMID(f) K/().

3.

The resistance represents a damper quantity B. The reactance represents a quantity of


the type (M K/). The impedance is defined as: Z = p/u where, p is the pressure and
u is the velocity.

4.

The impedance scale factor S is used in computing element stiffness and damping terms
as:

5.

To create a non-reflecting boundary, set the values of the TABLEDi entry referenced by
the TZREID field (Resistance-real part of Impedance) to be equal to
for all frequencies. This will allow the acoustic wave to propagate normally through the
boundary, without reflection. This condition is called the Sommerfeld boundary condition.
Where,

6.

is the density of the fluid and,

is the speed of sound in the fluid.

This card is represented as a property in HyperMesh.

1470 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PACABS
Bulk Data Entry
PACABS Frequency-Dependant Structural Acoustic Absorber Property
Description
Defines the properties of the structural acoustic absorber element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PAC ABS

PID

SYNTH

TID1

TID2

TID3

TESTAR

C UTFR

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PAC ABS

YES

1.

200.

Field

Contents

PID

Property identification number.

(9)

(10)

(Integer > 0)
SYNTH

Request the calculation of B, K, and M from the specified tables TIDi.


Default = YES (Character = YES or NO)

TID1

Identification of the TABLEDi entry that defines the resistance.


(Integer > 0 or Blank)

TID2

Identification of the TABLEDi entry that defines the reactance.

Altair Engineering

OptiStruct 13.0 Reference Guide 1471


Proprietary Information of Altair Engineering

Field

Contents
(Integer > 0 or Blank)

TID3

Identification of the TABLEDi entry that defines the weighting function.


(Integer > 0 or Blank)

TESTAR Area of the test specimen.


Default = 1.0 (Real > 0.0)
CUTFR

Cutoff frequency for tables referenced above.


(Real > 0.0)

B, K, M

Equivalent damping, stiffness and mass values per unit area.


K and M (Real > 0.0), B (Real)

Input File - chacab.fem


$$------------------------------------------------------------------------------$
$$
$
$$ NASTRAN Input Deck Generated by HyperMesh Version : 8.0SR1
$
$$ Generated using HyperMesh-Nastran Template Version : 8.0sr1
$$
$
$$
Template: general
$
$$
$
$$------------------------------------------------------------------------------$
$$------------------------------------------------------------------------------$
$$
Executive Control Cards
$
$$------------------------------------------------------------------------------$
SOL 111
CEND
$$------------------------------------------------------------------------------$
$$
Case Control Cards
$
$$------------------------------------------------------------------------------$
SET 1 = 1734
DISPLACEMENT = 1
$
$HMNAME LOADSTEP
1"Load2"
SUBCASE
1
LABEL=
Load2
SPC =
4
FREQUENCY =
5
DLOAD =
2
$$------------------------------------------------------------------------------$
$$
Bulk Data Cards
$
$$------------------------------------------------------------------------------$
BEGIN BULK
$CHEXA
$+

1056
1683

2
1672

1650

1661

1662

1651

1671

1472 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

1682+

Altair Engineering

CHACAB
1056
100
1650
1645
1657
+
1671
1672
PACABS,100,YES,1,2,3,1.5,10.0,2.0
PARAM,G,0.001
PARAM,COUPMASS,-1
PARAM,POST,-1
$ACMODL
DIFF
0.1
$$
EIGRL,20,,,300
EIGRL,21,,,300
$$ GRID Data
$$
GRID
1
2.0
2.0
0.0
GRID
2
2.0
1.5
0.0
GRID
3
2.0
1.0
0.0
GRID
4
2.0
0.5
0.0
GRID
5
2.0
0.0
0.0
GRID
6
2.0
-0.5
0.0
GRID
7
2.0
-1.0
0.0
GRID
8
2.0
-1.5
0.0
GRID
9
2.0
-2.0
0.0
GRID
10
1.5
2.0
0.0
GRID
11
1.5
1.5
0.0
GRID
12
1.5
1.0
0.0
GRID
13
1.5
0.5
0.0
GRID
14
1.5
0.0
0.0
GRID
15
1.5
-0.5
0.0
GRID
16
1.5
-1.0
0.0
GRID
17
1.5
-1.5
0.0
GRID
18
1.5
-2.0
0.0
GRID
19
1.0
2.0
0.0
GRID
20
1.0
1.5
0.0
GRID
21
1.0
1.0
0.0
GRID
22
1.0
0.5
0.0
GRID
23
1.0
0.0
0.0
GRID
24
1.0
-0.5
0.0
GRID
25
1.0
-1.0
0.0
GRID
26
1.0
-1.5
0.0
GRID
27
1.0
-2.0
0.0
GRID
28
0.5
2.0
0.0
GRID
29
0.5
1.5
0.0
GRID
30
0.5
1.0
0.0
GRID
31
0.5
0.5
0.0
GRID
32
0.5
0.0
0.0
GRID
33
0.5
-0.5
0.0
GRID
34
0.5
-1.0
0.0
GRID
35
0.5
-1.5
0.0
GRID
36
0.5
-2.0
0.0
GRID
37
0.0
2.0
0.0
GRID
38
0.0
1.5
0.0
GRID
39
0.0
1.0
0.0
GRID
40
0.0
0.5
0.0
GRID
41
0.0
0.0
0.0
GRID
42
0.0
-0.5
0.0
GRID
43
0.0
-1.0
0.0
GRID
44
0.0
-1.5
0.0
GRID
45
0.0
-2.0
0.0
GRID
46
-0.5
2.0
0.0
GRID
47
-0.5
1.5
0.0
GRID
48
-0.5
1.0
0.0
GRID
49
-0.5
0.5
0.0
GRID
50
-0.5
0.0
0.0
GRID
51
-0.5
-0.5
0.0
GRID
52
-0.5
-1.0
0.0
GRID
53
-0.5
-1.5
0.0
GRID
54
-0.5
-2.0
0.0
GRID
55
-1.0
2.0
0.0
GRID
56
-1.0
1.5
0.0
GRID
57
-1.0
1.0
0.0

Altair Engineering

1658

1676

1675+

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1473


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
727
728
729
730
731

-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
1.5
1.5
1.0
1.0
0.5
0.5
0.0
0.0
-0.5
-0.5
-1.0
-1.0
-1.5
-1.5
-2.0
-2.0
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5

0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
-2.5
2.5
2.0
2.0
2.5
1.5

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
1.0
1.0
1.0
1.0
1.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1474 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800

Altair Engineering

2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5

1.5
1.0
1.0
1.0
1.0
1.0
0.5
1.0
0.5
1.0
-4.2E-191.0
-6.5E-201.0
-0.5
1.0
-0.5
1.0
-1.0
1.0
-1.0
1.0
-1.5
1.0
-1.5
1.0
-2.0
1.0
-2.0
1.0
-2.5
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-9.8E-211.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-1.5E-211.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-2.3E-221.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-3.5E-231.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-5.3E-241.0
-0.5
1.0
-1.0
1.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1475


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869

-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0

-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-8.1E-251.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-9.3E-181.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-2.0E-181.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.0
1.0
2.5
1.0
1.5
1.0
1.0
1.0
0.5
1.0
-1.0E-181.0
-0.5
1.0
-1.0
1.0
-1.5
1.0
-2.0
1.0
-2.5
1.0
2.5
2.0
2.0
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.5
2.0
1.0
2.0
1.0
2.0
0.5
2.0
0.5
2.0
-6.0E-192.0
-1.2E-192.0
-0.5
2.0
-0.5
2.0
-1.0
2.0
-1.0
2.0
-1.5
2.0
-1.5
2.0
-2.0
2.0
-2.0
2.0
-2.5
2.0
-2.5
2.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1476 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938

Altair Engineering

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5

2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-2.1E-202.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-3.8E-212.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-6.7E-222.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-1.2E-222.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-2.0E-232.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-1.4E-182.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1477


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007

-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.5
2.5
2.0
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
1.0
1.0

1.0
2.0
0.5
2.0
-1.3E-172.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-4.1E-182.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.0
2.0
2.5
2.0
1.5
2.0
1.0
2.0
0.5
2.0
-2.5E-182.0
-0.5
2.0
-1.0
2.0
-1.5
2.0
-2.0
2.0
-2.5
2.0
2.5
3.0
2.0
3.0
2.0
3.0
2.5
3.0
1.5
3.0
1.5
3.0
1.0
3.0
1.0
3.0
0.5
3.0
0.5
3.0
-6.7E-193.0
-1.5E-193.0
-0.5
3.0
-0.5
3.0
-1.0
3.0
-1.0
3.0
-1.5
3.0
-1.5
3.0
-2.0
3.0
-2.0
3.0
-2.5
3.0
-2.5
3.0
2.0
3.0
2.5
3.0
1.5
3.0
1.0
3.0
0.5
3.0
-3.1E-203.0
-0.5
3.0
-1.0
3.0
-1.5
3.0
-2.0
3.0
-2.5
3.0
2.0
3.0
2.5
3.0
1.5
3.0
1.0
3.0
0.5
3.0
-6.2E-213.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1478 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076

Altair Engineering

1.0
-0.5
3.0
1.0
-1.0
3.0
1.0
-1.5
3.0
1.0
-2.0
3.0
1.0
-2.5
3.0
0.5
2.0
3.0
0.5
2.5
3.0
0.5
1.5
3.0
0.5
1.0
3.0
0.5
0.5
3.0
0.5
-1.2E-213.0
0.5
-0.5
3.0
0.5
-1.0
3.0
0.5
-1.5
3.0
0.5
-2.0
3.0
0.5
-2.5
3.0
1.50E-322.0
3.0
3.80E-332.5
3.0
2.67E-331.5
3.0
4.07E-341.0
3.0
6.20E-350.5
3.0
6.35E-32-2.3E-223.0
1.29E-31-0.5
3.0
-4.0E-32-1.0
3.0
-5.5E-32-1.5
3.0
-3.2E-32-2.0
3.0
-4.8E-33-2.5
3.0
-0.5
2.0
3.0
-0.5
2.5
3.0
-0.5
1.5
3.0
-0.5
1.0
3.0
-0.5
0.5
3.0
-0.5
-2.2E-193.0
-0.5
-0.5
3.0
-0.5
-1.0
3.0
-0.5
-1.5
3.0
-0.5
-2.0
3.0
-0.5
-2.5
3.0
-1.0
2.0
3.0
-1.0
2.5
3.0
-1.0
1.5
3.0
-1.0
1.0
3.0
-1.0
0.5
3.0
-1.0
-2.6E-183.0
-1.0
-0.5
3.0
-1.0
-1.0
3.0
-1.0
-1.5
3.0
-1.0
-2.0
3.0
-1.0
-2.5
3.0
-1.5
2.0
3.0
-1.5
2.5
3.0
-1.5
1.5
3.0
-1.5
1.0
3.0
-1.5
0.5
3.0
-1.5
-1.5E-173.0
-1.5
-0.5
3.0
-1.5
-1.0
3.0
-1.5
-1.5
3.0
-1.5
-2.0
3.0
-1.5
-2.5
3.0
-2.0
2.0
3.0
-2.0
2.5
3.0
-2.0
1.5
3.0
-2.0
1.0
3.0
-2.0
0.5
3.0
-2.0
-5.3E-183.0
-2.0
-0.5
3.0
-2.0
-1.0
3.0
-2.0
-1.5
3.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1479


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145

-2.0
-2.0
3.0
-2.0
-2.5
3.0
-2.5
2.0
3.0
-2.5
2.5
3.0
-2.5
1.5
3.0
-2.5
1.0
3.0
-2.5
0.5
3.0
-2.5
-3.3E-183.0
-2.5
-0.5
3.0
-2.5
-1.0
3.0
-2.5
-1.5
3.0
-2.5
-2.0
3.0
-2.5
-2.5
3.0
2.5
2.5
4.0
2.5
2.0
4.0
2.0
2.0
4.0
2.0
2.5
4.0
2.5
1.5
4.0
2.0
1.5
4.0
2.5
1.0
4.0
2.0
1.0
4.0
2.5
0.5
4.0
2.0
0.5
4.0
2.5
-1.0E-164.0
2.0
-1.8E-164.0
2.5
-0.5
4.0
2.0
-0.5
4.0
2.5
-1.0
4.0
2.0
-1.0
4.0
2.5
-1.5
4.0
2.0
-1.5
4.0
2.5
-2.0
4.0
2.0
-2.0
4.0
2.5
-2.5
4.0
2.0
-2.5
4.0
1.5
2.0
4.0
1.5
2.5
4.0
1.5
1.5
4.0
1.5
1.0
4.0
1.5
0.5
4.0
1.5
-3.1E-164.0
1.5
-0.5
4.0
1.5
-1.0
4.0
1.5
-1.5
4.0
1.5
-2.0
4.0
1.5
-2.5
4.0
1.0
2.0
4.0
1.0
2.5
4.0
1.0
1.5
4.0
1.0
1.0
4.0
1.0
0.5
4.0
1.0
-3.6E-164.0
1.0
-0.5
4.0
1.0
-1.0
4.0
1.0
-1.5
4.0
1.0
-2.0
4.0
1.0
-2.5
4.0
0.5
2.0
4.0
0.5
2.5
4.0
0.5
1.5
4.0
0.5
1.0
4.0
0.5
0.5
4.0
0.5
-2.8E-164.0
0.5
-0.5
4.0
0.5
-1.0
4.0
0.5
-1.5
4.0
0.5
-2.0
4.0
0.5
-2.5
4.0
-1.7E-162.0
4.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1480 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214

Altair Engineering

-2.3E-162.5
4.0
-2.7E-171.5
4.0
-3.0E-171.0
4.0
-7.0E-170.5
4.0
2.16E-17-1.4E-164.0
1.65E-16-0.5
4.0
3.53E-16-1.0
4.0
2.86E-16-1.5
4.0
-5.5E-17-2.0
4.0
-2.5E-16-2.5
4.0
-0.5
2.0
4.0
-0.5
2.5
4.0
-0.5
1.5
4.0
-0.5
1.0
4.0
-0.5
0.5
4.0
-0.5
-2.5E-174.0
-0.5
-0.5
4.0
-0.5
-1.0
4.0
-0.5
-1.5
4.0
-0.5
-2.0
4.0
-0.5
-2.5
4.0
-1.0
2.0
4.0
-1.0
2.5
4.0
-1.0
1.5
4.0
-1.0
1.0
4.0
-1.0
0.5
4.0
-1.0
9.63E-174.0
-1.0
-0.5
4.0
-1.0
-1.0
4.0
-1.0
-1.5
4.0
-1.0
-2.0
4.0
-1.0
-2.5
4.0
-1.5
2.0
4.0
-1.5
2.5
4.0
-1.5
1.5
4.0
-1.5
1.0
4.0
-1.5
0.5
4.0
-1.5
2.14E-164.0
-1.5
-0.5
4.0
-1.5
-1.0
4.0
-1.5
-1.5
4.0
-1.5
-2.0
4.0
-1.5
-2.5
4.0
-2.0
2.0
4.0
-2.0
2.5
4.0
-2.0
1.5
4.0
-2.0
1.0
4.0
-2.0
0.5
4.0
-2.0
1.84E-164.0
-2.0
-0.5
4.0
-2.0
-1.0
4.0
-2.0
-1.5
4.0
-2.0
-2.0
4.0
-2.0
-2.5
4.0
-2.5
2.0
4.0
-2.5
2.5
4.0
-2.5
1.5
4.0
-2.5
1.0
4.0
-2.5
0.5
4.0
-2.5
1.10E-164.0
-2.5
-0.5
4.0
-2.5
-1.0
4.0
-2.5
-1.5
4.0
-2.5
-2.0
4.0
-2.5
-2.5
4.0
2.5
2.5
5.0
2.5
2.0
5.0
2.0
2.0
5.0
2.0
2.5
5.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1481


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283

2.5
1.5
5.0
2.0
1.5
5.0
2.5
1.0
5.0
2.0
1.0
5.0
2.5
0.5
5.0
2.0
0.5
5.0
2.5
-1.8E-165.0
2.0
-2.4E-165.0
2.5
-0.5
5.0
2.0
-0.5
5.0
2.5
-1.0
5.0
2.0
-1.0
5.0
2.5
-1.5
5.0
2.0
-1.5
5.0
2.5
-2.0
5.0
2.0
-2.0
5.0
2.5
-2.5
5.0
2.0
-2.5
5.0
1.5
2.0
5.0
1.5
2.5
5.0
1.5
1.5
5.0
1.5
1.0
5.0
1.5
0.5
5.0
1.5
-2.8E-165.0
1.5
-0.5
5.0
1.5
-1.0
5.0
1.5
-1.5
5.0
1.5
-2.0
5.0
1.5
-2.5
5.0
1.0
2.0
5.0
1.0
2.5
5.0
1.0
1.5
5.0
1.0
1.0
5.0
1.0
0.5
5.0
1.0
-3.0E-165.0
1.0
-0.5
5.0
1.0
-1.0
5.0
1.0
-1.5
5.0
1.0
-2.0
5.0
1.0
-2.5
5.0
0.5
2.0
5.0
0.5
2.5
5.0
0.5
1.5
5.0
0.5
1.0
5.0
0.5
0.5
5.0
0.5
-2.4E-165.0
0.5
-0.5
5.0
0.5
-1.0
5.0
0.5
-1.5
5.0
0.5
-2.0
5.0
0.5
-2.5
5.0
-2.4E-162.0
5.0
-2.4E-162.5
5.0
-1.4E-161.5
5.0
-1.1E-161.0
5.0
-6.8E-170.5
5.0
-2.1E-17-1.4E-165.0
1.13E-16-0.5
5.0
2.64E-16-1.0
5.0
2.07E-16-1.5
5.0
-8.9E-18-2.0
5.0
-1.0E-16-2.5
5.0
-0.5
2.0
5.0
-0.5
2.5
5.0
-0.5
1.5
5.0
-0.5
1.0
5.0
-0.5
0.5
5.0
-0.5
-2.9E-175.0
-0.5
-0.5
5.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

1482 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352

Altair Engineering

-0.5
-0.5
-0.5
-0.5
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-1.5
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
-2.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0

-1.0
5.0
-1.5
5.0
-2.0
5.0
-2.5
5.0
2.0
5.0
2.5
5.0
1.5
5.0
1.0
5.0
0.5
5.0
8.84E-175.0
-0.5
5.0
-1.0
5.0
-1.5
5.0
-2.0
5.0
-2.5
5.0
2.0
5.0
2.5
5.0
1.5
5.0
1.0
5.0
0.5
5.0
1.34E-165.0
-0.5
5.0
-1.0
5.0
-1.5
5.0
-2.0
5.0
-2.5
5.0
2.0
5.0
2.5
5.0
1.5
5.0
1.0
5.0
0.5
5.0
1.09E-165.0
-0.5
5.0
-1.0
5.0
-1.5
5.0
-2.0
5.0
-2.5
5.0
2.0
5.0
2.5
5.0
1.5
5.0
1.0
5.0
0.5
5.0
5.75E-175.0
-0.5
5.0
-1.0
5.0
-1.5
5.0
-2.0
5.0
-2.5
5.0
2.0
0.0
1.5
0.0
1.0
0.0
0.5
0.0
-2.2E-180.0
-0.5
0.0
-1.0
0.0
-1.5
0.0
-2.0
0.0
2.0
0.0
1.5
0.0
1.0
0.0
0.5
0.0
-1.9E-180.0
-0.5
0.0
-1.0
0.0
-1.5
0.0
-2.0
0.0
2.0
0.0
1.5
0.0
1.0
0.0

-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1

OptiStruct 13.0 Reference Guide 1483


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421

1.0
0.5
0.0
1.0
-1.9E-180.0
1.0
-0.5
0.0
1.0
-1.0
0.0
1.0
-1.5
0.0
1.0
-2.0
0.0
0.5
2.0
0.0
0.5
1.5
0.0
0.5
1.0
0.0
0.5
0.5
0.0
0.5
-1.9E-180.0
0.5
-0.5
0.0
0.5
-1.0
0.0
0.5
-1.5
0.0
0.5
-2.0
0.0
-2.8E-182.0
0.0
-2.8E-181.5
0.0
-2.5E-181.0
0.0
-2.8E-180.5
0.0
-3.1E-18-1.7E-180.0
-2.8E-18-0.5
0.0
-3.1E-18-1.0
0.0
-1.9E-18-1.5
0.0
-2.8E-18-2.0
0.0
-0.5
2.0
0.0
-0.5
1.5
0.0
-0.5
1.0
0.0
-0.5
0.5
0.0
-0.5
-1.7E-180.0
-0.5
-0.5
0.0
-0.5
-1.0
0.0
-0.5
-1.5
0.0
-0.5
-2.0
0.0
-1.0
2.0
0.0
-1.0
1.5
0.0
-1.0
1.0
0.0
-1.0
0.5
0.0
-1.0
-1.9E-180.0
-1.0
-0.5
0.0
-1.0
-1.0
0.0
-1.0
-1.5
0.0
-1.0
-2.0
0.0
-1.5
2.0
0.0
-1.5
1.5
0.0
-1.5
1.0
0.0
-1.5
0.5
0.0
-1.5
-1.7E-180.0
-1.5
-0.5
0.0
-1.5
-1.0
0.0
-1.5
-1.5
0.0
-1.5
-2.0
0.0
-2.0
2.0
0.0
-2.0
1.5
0.0
-2.0
1.0
0.0
-2.0
0.5
0.0
-2.0
-2.2E-180.0
-2.0
-0.5
0.0
-2.0
-1.0
0.0
-2.0
-1.5
0.0
-2.0
-2.0
0.0
2.4964642.0
0.004472
2.4964641.5
0.004472
2.4964641.0
0.004472
2.4964640.5
0.004472
2.496464-2.6E-180.004472
2.496464-0.5
0.004472
2.496464-1.0
0.004472
2.496464-1.5
0.004472
2.496464-2.0
0.004472

1484 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1493

Altair Engineering

-2.496462.0
0.004472
-2.496461.5
0.004472
-2.496461.0
0.004472
-2.496460.5
0.004472
-2.49646-2.6E-180.004472
-2.49646-0.5
0.004472
-2.49646-1.0
0.004472
-2.49646-1.5
0.004472
-2.49646-2.0
0.004472
2.4961522.4961520.005963
2.496152-2.496150.005963
2.0
2.4964640.004472
2.0
-2.496460.004472
1.5
2.4964640.004472
1.5
-2.496460.004472
1.0
2.4964640.004472
1.0
-2.496460.004472
0.5
2.4964640.004472
0.5
-2.496460.004472
-2.6E-182.4964640.004472
-2.6E-18-2.496460.004472
-0.5
2.4964640.004472
-0.5
-2.496460.004472
-1.0
2.4964640.004472
-1.0
-2.496460.004472
-1.5
2.4964640.004472
-1.5
-2.496460.004472
-2.0
2.4964640.004472
-2.0
-2.496460.004472
-2.496152.4961520.005963
-2.49615-2.496150.005963
-2.49615-2.496154.994037
-2.49646-2.0
4.995528
-2.49646-1.5
4.995528
-2.49646-1.0
4.995528
-2.49646-0.5
4.995528
-2.496465.58E-174.995528
-2.496460.5
4.995528
-2.496461.0
4.995528
-2.496461.5
4.995528
-2.496152.4961524.994037
-2.496462.0
4.995528
-2.0
-2.496464.995528
-2.0
-2.0
5.0
-2.0
-1.5
5.0
-2.0
-1.0
5.0
-2.0
-0.5
5.0
-2.0
1.05E-165.0
-2.0
0.5
5.0
-2.0
1.0
5.0
-2.0
1.5
5.0
-2.0
2.4964644.995528
-2.0
2.0
5.0
-1.5
-2.496464.995528
-1.5
-2.0
5.0
-1.5
-1.5
5.0
-1.5
-1.0
5.0
-1.5
-0.5
5.0
-1.5
1.32E-165.0
-1.5
0.5
5.0
-1.5
1.0
5.0
-1.5
1.5
5.0
-1.5
2.4964644.995528
-1.5
2.0
5.0
-1.0
-2.496464.995528
-1.0
-2.0
5.0
-1.0
-1.5
5.0
-1.0
-1.0
5.0
-1.0
1.0
5.0

OptiStruct 13.0 Reference Guide 1485


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1494
1495
1496
1497
1498
1499
1500
1504
1505
1506
1507
1508
1509
1510
1511
1515
1516
1517
1518
1519
1520
1521
1522
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571

-1.0
1.5
5.0
-1.0
2.4964644.995528
-1.0
2.0
5.0
-0.5
-2.496464.995528
-0.5
-2.0
5.0
-0.5
-1.5
5.0
-0.5
-1.0
5.0
-0.5
1.0
5.0
-0.5
1.5
5.0
-0.5
2.4964644.995528
-0.5
2.0
5.0
-1.0E-16-2.496464.995528
-1.1E-17-2.0
5.0
2.04E-16-1.5
5.0
2.61E-16-1.0
5.0
-1.2E-161.0
5.0
-1.4E-161.5
5.0
-2.4E-162.4964644.995528
-2.4E-162.0
5.0
0.5
-2.496464.995528
0.5
-2.0
5.0
0.5
-1.5
5.0
0.5
-1.0
5.0
0.5
1.0
5.0
0.5
1.5
5.0
0.5
2.4964644.995528
0.5
2.0
5.0
1.0
-2.496464.995528
1.0
-2.0
5.0
1.0
-1.5
5.0
1.0
-1.0
5.0
1.0
-0.5
5.0
1.0
-3.0E-165.0
1.0
0.5
5.0
1.0
1.0
5.0
1.0
1.5
5.0
1.0
2.4964644.995528
1.0
2.0
5.0
1.5
-2.496464.995528
1.5
-2.0
5.0
1.5
-1.5
5.0
1.5
-1.0
5.0
1.5
-0.5
5.0
1.5
-2.8E-165.0
1.5
0.5
5.0
1.5
1.0
5.0
1.5
1.5
5.0
1.5
2.4964644.995528
1.5
2.0
5.0
2.0
-2.496464.995528
2.496152-2.496154.994037
2.0
-2.0
5.0
2.496464-2.0
4.995528
2.0
-1.5
5.0
2.496464-1.5
4.995528
2.0
-1.0
5.0
2.496464-1.0
4.995528
2.0
-0.5
5.0
2.496464-0.5
4.995528
2.0
-2.4E-165.0
2.496464-1.8E-164.995528
2.0
0.5
5.0
2.4964640.5
4.995528
2.0
1.0
5.0
2.4964641.0
4.995528
2.0
1.5
5.0
2.4964641.5
4.995528
2.0
2.4964644.995528
2.0
2.0
5.0

1486 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640

Altair Engineering

2.4964642.0
4.995528
2.4961522.4961524.994037
-2.49776-2.497764.0
-2.5
-2.0
4.0
-2.5
-1.5
4.0
-2.5
-1.0
4.0
-2.5
-0.5
4.0
-2.5
1.07E-164.0
-2.5
0.5
4.0
-2.5
1.0
4.0
-2.5
1.5
4.0
-2.497762.4977644.0
-2.5
2.0
4.0
-2.0
-2.5
4.0
-2.0
2.5
4.0
-1.5
-2.5
4.0
-1.5
2.5
4.0
-1.0
-2.5
4.0
-1.0
2.5
4.0
-0.5
-2.5
4.0
-0.5
2.5
4.0
-2.5E-16-2.5
4.0
-2.3E-162.5
4.0
0.5
-2.5
4.0
0.5
2.5
4.0
1.0
-2.5
4.0
1.0
2.5
4.0
1.5
-2.5
4.0
1.5
2.5
4.0
2.0
-2.5
4.0
2.497764-2.497764.0
2.5
-2.0
4.0
2.5
-1.5
4.0
2.5
-1.0
4.0
2.5
-0.5
4.0
2.5
-1.0E-164.0
2.5
0.5
4.0
2.5
1.0
4.0
2.5
1.5
4.0
2.0
2.5
4.0
2.5
2.0
4.0
2.4977642.4977644.0
-2.49776-2.497763.0
-2.5
-2.0
3.0
-2.5
-1.5
3.0
-2.5
-1.0
3.0
-2.5
-0.5
3.0
-2.5
-5.4E-183.0
-2.5
0.5
3.0
-2.5
1.0
3.0
-2.5
1.5
3.0
-2.497762.4977643.0
-2.5
2.0
3.0
-2.0
-2.5
3.0
-2.0
2.5
3.0
-1.5
-2.5
3.0
-1.5
2.5
3.0
-1.0
-2.5
3.0
-1.0
2.5
3.0
-0.5
-2.5
3.0
-0.5
2.5
3.0
-2.9E-18-2.5
3.0
-3.1E-182.5
3.0
0.5
-2.5
3.0
0.5
2.5
3.0
1.0
-2.5
3.0
1.0
2.5
3.0
1.5
-2.5
3.0
1.5
2.5
3.0

OptiStruct 13.0 Reference Guide 1487


Proprietary Information of Altair Engineering

GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID
GRID

1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709

2.0
-2.5
3.0
2.497764-2.497763.0
2.5
-2.0
3.0
2.5
-1.5
3.0
2.5
-1.0
3.0
2.5
-0.5
3.0
2.5
-3.4E-183.0
2.5
0.5
3.0
2.5
1.0
3.0
2.5
1.5
3.0
2.0
2.5
3.0
2.5
2.0
3.0
2.4977642.4977643.0
-2.49776-2.497762.0
-2.5
-2.0
2.0
-2.5
-1.5
2.0
-2.5
-1.0
2.0
-2.5
-0.5
2.0
-2.5
-5.0E-182.0
-2.5
0.5
2.0
-2.5
1.0
2.0
-2.5
1.5
2.0
-2.497762.4977642.0
-2.5
2.0
2.0
-2.0
-2.5
2.0
-2.0
2.5
2.0
-1.5
-2.5
2.0
-1.5
2.5
2.0
-1.0
-2.5
2.0
-1.0
2.5
2.0
-0.5
-2.5
2.0
-0.5
2.5
2.0
-2.5E-18-2.5
2.0
-2.5E-182.5
2.0
0.5
-2.5
2.0
0.5
2.5
2.0
1.0
-2.5
2.0
1.0
2.5
2.0
1.5
-2.5
2.0
1.5
2.5
2.0
2.0
-2.5
2.0
2.497764-2.497762.0
2.5
-2.0
2.0
2.5
-1.5
2.0
2.5
-1.0
2.0
2.5
-0.5
2.0
2.5
-3.1E-182.0
2.5
0.5
2.0
2.5
1.0
2.0
2.5
1.5
2.0
2.0
2.5
2.0
2.5
2.0
2.0
2.4977642.4977642.0
-2.49776-2.497761.0
-2.5
-2.0
1.0
-2.5
-1.5
1.0
-2.5
-1.0
1.0
-2.5
-0.5
1.0
-2.5
-3.5E-181.0
-2.5
0.5
1.0
-2.5
1.0
1.0
-2.5
1.5
1.0
-2.497762.4977641.0
-2.5
2.0
1.0
-2.0
-2.5
1.0
-2.0
2.5
1.0
-1.5
-2.5
1.0
-1.5
2.5
1.0
-1.0
-2.5
1.0

1488 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

GRID
1710
-1.0
2.5
1.0
GRID
1711
-0.5
-2.5
1.0
GRID
1712
-0.5
2.5
1.0
GRID
1713
-2.5E-18-2.5
1.0
GRID
1714
-2.5E-182.5
1.0
GRID
1715
0.5
-2.5
1.0
GRID
1716
0.5
2.5
1.0
GRID
1717
1.0
-2.5
1.0
GRID
1718
1.0
2.5
1.0
GRID
1719
1.5
-2.5
1.0
GRID
1720
1.5
2.5
1.0
GRID
1721
2.0
-2.5
1.0
GRID
1722
2.497764-2.497761.0
GRID
1723
2.5
-2.0
1.0
GRID
1724
2.5
-1.5
1.0
GRID
1725
2.5
-1.0
1.0
GRID
1726
2.5
-0.5
1.0
GRID
1727
2.5
-2.9E-181.0
GRID
1728
2.5
0.5
1.0
GRID
1729
2.5
1.0
1.0
GRID
1730
2.5
1.5
1.0
GRID
1731
2.0
2.5
1.0
GRID
1732
2.5
2.0
1.0
GRID
1733
2.4977642.4977641.0
GRID
1734
-0.25
3.33E-165.0
$$
$$ SPOINT Data
$$
$$
$$------------------------------------------------------------------------------$
$$
Group Definitions
$
$$------------------------------------------------------------------------------$
$$
$$ RBE2 Elements - Multiple dependent nodes
$$
RBE2
1553
1734 123456
1478
1479
1480
1481
1482+
+
1489
1493
1500
1504
1511
1515
1522
1526+
+
1533
1534
1535
1536
1537
$
$HMMOVE
6
$
1553
$
$ CQUAD4 Elements
$
CQUAD4
1101
4
1332
1341
1342
1333
CQUAD4
1102
4
1333
1342
1343
1334
CQUAD4
1103
4
1334
1343
1344
1335
CQUAD4
1104
4
1335
1344
1345
1336
CQUAD4
1105
4
1336
1345
1346
1337
CQUAD4
1106
4
1337
1346
1347
1338
CQUAD4
1107
4
1338
1347
1348
1339
CQUAD4
1108
4
1339
1348
1349
1340
CQUAD4
1109
4
1341
1350
1351
1342
CQUAD4
1110
4
1342
1351
1352
1343
CQUAD4
1111
4
1343
1352
1353
1344
CQUAD4
1112
4
1344
1353
1354
1345
CQUAD4
1113
4
1345
1354
1355
1346
CQUAD4
1114
4
1346
1355
1356
1347
CQUAD4
1115
4
1347
1356
1357
1348
CQUAD4
1116
4
1348
1357
1358
1349
CQUAD4
1117
4
1350
1359
1360
1351
CQUAD4
1118
4
1351
1360
1361
1352
CQUAD4
1119
4
1352
1361
1362
1353
CQUAD4
1120
4
1353
1362
1363
1354
CQUAD4
1121
4
1354
1363
1364
1355
CQUAD4
1122
4
1355
1364
1365
1356
CQUAD4
1123
4
1356
1365
1366
1357
CQUAD4
1124
4
1357
1366
1367
1358
CQUAD4
1125
4
1359
1368
1369
1360

Altair Engineering

OptiStruct 13.0 Reference Guide 1489


Proprietary Information of Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1360
1361
1362
1363
1364
1365
1366
1368
1369
1370
1371
1372
1373
1374
1375
1377
1378
1379
1380
1381
1382
1383
1384
1386
1387
1388
1389
1390
1391
1392
1393
1395
1396
1397
1398
1399
1400
1401
1402
1413
1414
1415
1416
1417
1418
1419
1420
1404
1405
1406
1407
1408
1409
1410
1411
1431
1433
1421
1340
1435
1349
1437
1358
1439
1367
1441
1376
1443
1385

1369
1370
1371
1372
1373
1374
1375
1377
1378
1379
1380
1381
1382
1383
1384
1386
1387
1388
1389
1390
1391
1392
1393
1395
1396
1397
1398
1399
1400
1401
1402
1404
1405
1406
1407
1408
1409
1410
1411
1332
1333
1334
1335
1336
1337
1338
1339
1422
1423
1424
1425
1426
1427
1428
1429
1433
1435
1340
1349
1437
1358
1439
1367
1441
1376
1443
1385
1445
1394

1370
1371
1372
1373
1374
1375
1376
1378
1379
1380
1381
1382
1383
1384
1385
1387
1388
1389
1390
1391
1392
1393
1394
1396
1397
1398
1399
1400
1401
1402
1403
1405
1406
1407
1408
1409
1410
1411
1412
1333
1334
1335
1336
1337
1338
1339
1340
1423
1424
1425
1426
1427
1428
1429
1430
1332
1341
1434
1436
1350
1438
1359
1440
1368
1442
1377
1444
1386
1446

1361
1362
1363
1364
1365
1366
1367
1369
1370
1371
1372
1373
1374
1375
1376
1378
1379
1380
1381
1382
1383
1384
1385
1387
1388
1389
1390
1391
1392
1393
1394
1396
1397
1398
1399
1400
1401
1402
1403
1414
1415
1416
1417
1418
1419
1420
1421
1405
1406
1407
1408
1409
1410
1411
1412
1413
1332
1432
1434
1341
1436
1350
1438
1359
1440
1368
1442
1377
1444

1490 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263

Altair Engineering

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1445
1394
1447
1403
1449
1412
1431
1413
1414
1433
1415
1416
1417
1418
1419
1420
1421
1432
1434
1436
1435
1438
1437
1440
1439
1442
1441
1444
1443
1446
1445
1448
1447
1450
1449
1452
1451
1422
1423
1424
1425
1426
1427
1428
1429
1430
1732
1733
1730
1731
1729
1728
1727
1726
1725
1724
1723
1722
1721
1719
1720
1717
1718
1715
1716
1713
1714
1711
1712

1447
1403
1449
1412
1451
1430
1733
1732
1730
1731
1729
1728
1727
1726
1725
1724
1723
1722
1721
1719
1720
1717
1718
1715
1716
1713
1714
1711
1712
1709
1710
1707
1708
1705
1706
1694
1703
1704
1702
1701
1700
1699
1698
1697
1696
1695
1692
1693
1690
1691
1689
1688
1687
1686
1685
1684
1683
1682
1681
1679
1680
1677
1678
1675
1676
1673
1674
1671
1672

1395
1448
1404
1450
1422
1452
1731
1733
1732
1720
1730
1729
1728
1727
1726
1725
1724
1723
1722
1721
1718
1719
1716
1717
1714
1715
1712
1713
1710
1711
1708
1709
1706
1707
1703
1705
1704
1702
1701
1700
1699
1698
1697
1696
1695
1694
1693
1691
1692
1680
1690
1689
1688
1687
1686
1685
1684
1683
1682
1681
1678
1679
1676
1677
1674
1675
1672
1673
1670

1386
1446
1395
1448
1404
1450
1433
1431
1413
1435
1414
1415
1416
1417
1418
1419
1420
1421
1432
1434
1437
1436
1439
1438
1441
1440
1443
1442
1445
1444
1447
1446
1449
1448
1451
1450
1422
1423
1424
1425
1426
1427
1428
1429
1430
1452
1733
1731
1732
1720
1730
1729
1728
1727
1726
1725
1724
1723
1722
1721
1718
1719
1716
1717
1714
1715
1712
1713
1710

OptiStruct 13.0 Reference Guide 1491


Proprietary Information of Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1709
1710
1707
1708
1705
1706
1694
1703
1704
1702
1701
1700
1699
1698
1697
1696
1695
1692
1693
1690
1691
1689
1688
1687
1686
1685
1684
1683
1682
1681
1679
1680
1677
1678
1675
1676
1673
1674
1671
1672
1669
1670
1667
1668
1665
1666
1654
1663
1664
1662
1661
1660
1659
1658
1657
1656
1655
1652
1653
1650
1651
1649
1648
1647
1646
1645
1644
1643
1642

1669
1670
1667
1668
1665
1666
1654
1663
1664
1662
1661
1660
1659
1658
1657
1656
1655
1652
1653
1650
1651
1649
1648
1647
1646
1645
1644
1643
1642
1641
1639
1640
1637
1638
1635
1636
1633
1634
1631
1632
1629
1630
1627
1628
1625
1626
1614
1623
1624
1622
1621
1620
1619
1618
1617
1616
1615
1612
1613
1610
1611
1609
1608
1607
1606
1605
1604
1603
1602

1671
1668
1669
1666
1667
1663
1665
1664
1662
1661
1660
1659
1658
1657
1656
1655
1654
1653
1651
1652
1640
1650
1649
1648
1647
1646
1645
1644
1643
1642
1641
1638
1639
1636
1637
1634
1635
1632
1633
1630
1631
1628
1629
1626
1627
1623
1625
1624
1622
1621
1620
1619
1618
1617
1616
1615
1614
1613
1611
1612
1600
1610
1609
1608
1607
1606
1605
1604
1603

1711
1708
1709
1706
1707
1703
1705
1704
1702
1701
1700
1699
1698
1697
1696
1695
1694
1693
1691
1692
1680
1690
1689
1688
1687
1686
1685
1684
1683
1682
1681
1678
1679
1676
1677
1674
1675
1672
1673
1670
1671
1668
1669
1666
1667
1663
1665
1664
1662
1661
1660
1659
1658
1657
1656
1655
1654
1653
1651
1652
1640
1650
1649
1648
1647
1646
1645
1644
1643

1492 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401

Altair Engineering

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1641
1639
1640
1637
1638
1635
1636
1633
1634
1631
1632
1629
1630
1627
1628
1625
1626
1614
1623
1624
1622
1621
1620
1619
1618
1617
1616
1615
1612
1613
1610
1572
1611
1569
1609
1567
1608
1565
1607
1563
1606
1561
1605
1559
1604
1557
1603
1555
1602
1601
1553
1599
1571
1568
1600
1566
1564
1562
1560
1558
1556
1554
1552
1597
1551
1549
1598
1548
1547

1601
1599
1600
1597
1598
1595
1596
1593
1594
1591
1592
1589
1590
1587
1588
1585
1586
1574
1583
1584
1582
1581
1580
1579
1578
1577
1576
1575
1572
1573
1569
1571
1570
1568
1567
1566
1565
1564
1563
1562
1561
1560
1559
1558
1557
1556
1555
1554
1553
1552
1552
1541
1551
1549
1550
1548
1547
1546
1545
1544
1543
1542
1541
1530
1540
1538
1539
1537
1536

1602
1601
1598
1599
1596
1597
1594
1595
1592
1593
1590
1591
1588
1589
1586
1587
1583
1585
1584
1582
1581
1580
1579
1578
1577
1576
1575
1574
1573
1570
1572
1570
1550
1571
1569
1568
1567
1566
1565
1564
1563
1562
1561
1560
1559
1558
1557
1556
1555
1553
1554
1552
1550
1551
1539
1549
1548
1547
1546
1545
1544
1543
1542
1541
1539
1540
1528
1538
1537

1642
1641
1638
1639
1636
1637
1634
1635
1632
1633
1630
1631
1628
1629
1626
1627
1623
1625
1624
1622
1621
1620
1619
1618
1617
1616
1615
1614
1613
1611
1612
1573
1600
1572
1610
1569
1609
1567
1608
1565
1607
1563
1606
1561
1605
1559
1604
1557
1603
1602
1555
1601
1570
1571
1598
1568
1566
1564
1562
1560
1558
1556
1554
1599
1550
1551
1596
1549
1548

OptiStruct 13.0 Reference Guide 1493


Proprietary Information of Altair Engineering

CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4
CQUAD4

1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1417
1418
1419
1420
1421
1422
1423
1424
1429
1430
1431
1432
1433
1434
1435
1436
1441
1442
1443
1444
1445
1446
1447
1448
1453
1454
1455
1456
1457
1458
1459
1460
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

1546
1545
1544
1543
1542
1541
1595
1540
1538
1596
1537
1532
1531
1530
1593
1529
1527
1594
1526
1521
1520
1519
1591
1518
1516
1592
1515
1510
1509
1508
1589
1507
1505
1590
1504
1499
1498
1497
1587
1496
1494
1588
1493
1488
1487
1486
1585
1485
1483
1586
1482
1481
1480
1479
1478
1477
1476
1475
1574
1583
1474
1584
1472
1582
1471
1581
1470
1580
1469

1535
1534
1533
1532
1531
1530
1519
1529
1527
1528
1526
1521
1520
1519
1508
1518
1516
1517
1515
1510
1509
1508
1497
1507
1505
1506
1504
1499
1498
1497
1486
1496
1494
1495
1493
1488
1487
1486
1475
1485
1483
1484
1482
1477
1476
1475
1464
1474
1472
1473
1471
1470
1469
1468
1467
1466
1465
1464
1453
1462
1463
1463
1461
1461
1460
1460
1459
1459
1458

1536
1535
1534
1533
1532
1531
1530
1528
1529
1517
1527
1522
1521
1520
1519
1517
1518
1506
1516
1511
1510
1509
1508
1506
1507
1495
1505
1500
1499
1498
1497
1495
1496
1484
1494
1489
1488
1487
1486
1484
1485
1473
1483
1478
1477
1476
1475
1473
1474
1462
1472
1471
1470
1469
1468
1467
1466
1465
1464
1463
1462
1461
1463
1460
1461
1459
1460
1458
1459

1547
1546
1545
1544
1543
1542
1597
1539
1540
1594
1538
1533
1532
1531
1595
1528
1529
1592
1527
1522
1521
1520
1593
1517
1518
1590
1516
1511
1510
1509
1591
1506
1507
1588
1505
1500
1499
1498
1589
1495
1496
1586
1494
1489
1488
1487
1587
1484
1485
1583
1483
1482
1481
1480
1479
1478
1477
1476
1585
1584
1473
1582
1474
1581
1472
1580
1471
1579
1470

1494 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD4
1491
4
1579
CQUAD4
1492
4
1468
CQUAD4
1493
4
1578
CQUAD4
1494
4
1467
CQUAD4
1495
4
1577
CQUAD4
1496
4
1466
CQUAD4
1497
4
1576
CQUAD4
1498
4
1465
CQUAD4
1499
4
1575
CQUAD4
1500
4
1464
$
$ CHEXA Elements: First Order
$
CHEXA
601
1
100
+
729
728
CHEXA
602
1
82
+
732
731
CHEXA
603
1
83
+
734
733
CHEXA
604
1
84
+
736
735
CHEXA
605
1
85
+
738
737
CHEXA
606
1
86
+
740
739
CHEXA
607
1
87
+
742
741
CHEXA
608
1
88
+
744
743
CHEXA
609
1
89
+
746
745
CHEXA
610
1
90
+
748
747
CHEXA
611
1
102
+
749
729
CHEXA
612
1
1
+
751
732
CHEXA
613
1
2
+
752
734
CHEXA
614
1
3
+
753
736
CHEXA
615
1
4
+
754
738
CHEXA
616
1
5
+
755
740
CHEXA
617
1
6
+
756
742
CHEXA
618
1
7
+
757
744
CHEXA
619
1
8
+
758
746
CHEXA
620
1
9
+
759
748
CHEXA
621
1
104
+
760
749
CHEXA
622
1
10
+
762
751
CHEXA
623
1
11
+
763
752
CHEXA
624
1
12
+
764
753
CHEXA
625
1
13
+
765
754
CHEXA
626
1
14
+
766
755
CHEXA
627
1
15
+
767
756
CHEXA
628
1
16
+
768
757

Altair Engineering

1458
1457
1457
1456
1456
1455
1455
1454
1454
1453

1457
1458
1456
1457
1455
1456
1454
1455
1453
1454

1578
1469
1577
1468
1576
1467
1575
1466
1574
1465

102

82

727

730+

83

728

729+

84

731

732+

85

733

734+

86

735

736+

87

737

738+

88

739

740+

89

741

742+

90

743

744+

103

101

745

746+

104

10

730

750+

10

11

729

749+

11

12

732

751+

12

13

734

752+

13

14

736

753+

14

15

738

754+

15

16

740

755+

16

17

742

756+

17

18

744

757+

18

105

103

746

758+

106

19

10

750

761+

19

20

11

749

760+

20

21

12

751

762+

21

22

13

752

763+

22

23

14

753

764+

23

24

15

754

765+

24

25

16

755

766+

25

26

17

756

767+

OptiStruct 13.0 Reference Guide 1495


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

629
769
630
770
631
771
632
773
633
774
634
775
635
776
636
777
637
778
638
779
639
780
640
781
641
782
642
784
643
785
644
786
645
787
646
788
647
789
648
790
649
791
650
792
651
793
652
795
653
796
654
797
655
798
656
799
657
800
658
801
659
802
660
803
661
804
662
806
663

1
758
1
759
1
760
1
762
1
763
1
764
1
765
1
766
1
767
1
768
1
769
1
770
1
771
1
773
1
774
1
775
1
776
1
777
1
778
1
779
1
780
1
781
1
782
1
784
1
785
1
786
1
787
1
788
1
789
1
790
1
791
1
792
1
793
1
795
1

17

26

27

18

757

768+

18

27

107

105

758

769+

106

108

28

19

761

772+

19

28

29

20

760

771+

20

29

30

21

762

773+

21

30

31

22

763

774+

22

31

32

23

764

775+

23

32

33

24

765

776+

24

33

34

25

766

777+

25

34

35

26

767

778+

26

35

36

27

768

779+

27

36

109

107

769

780+

108

110

37

28

772

783+

28

37

38

29

771

782+

29

38

39

30

773

784+

30

39

40

31

774

785+

31

40

41

32

775

786+

32

41

42

33

776

787+

33

42

43

34

777

788+

34

43

44

35

778

789+

35

44

45

36

779

790+

36

45

111

109

780

791+

110

112

46

37

783

794+

37

46

47

38

782

793+

38

47

48

39

784

795+

39

48

49

40

785

796+

40

49

50

41

786

797+

41

50

51

42

787

798+

42

51

52

43

788

799+

43

52

53

44

789

800+

44

53

54

45

790

801+

45

54

113

111

791

802+

112

114

55

46

794

805+

46

55

56

47

793

804+

47

56

57

48

795

806+

1496 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

807
664
808
665
809
666
810
667
811
668
812
669
813
670
814
671
815
672
817
673
818
674
819
675
820
676
821
677
822
678
823
679
824
680
825
681
826
682
828
683
829
684
830
685
831
686
832
687
833
688
834
689
835
690
836
691
837
692
839
693
840
694
841
695
842
696
843
697
844

Altair Engineering

796
1
797
1
798
1
799
1
800
1
801
1
802
1
803
1
804
1
806
1
807
1
808
1
809
1
810
1
811
1
812
1
813
1
814
1
815
1
817
1
818
1
819
1
820
1
821
1
822
1
823
1
824
1
825
1
826
1
828
1
829
1
830
1
831
1
832
1
833

48

57

58

49

796

807+

49

58

59

50

797

808+

50

59

60

51

798

809+

51

60

61

52

799

810+

52

61

62

53

800

811+

53

62

63

54

801

812+

54

63

115

113

802

813+

114

116

64

55

805

816+

55

64

65

56

804

815+

56

65

66

57

806

817+

57

66

67

58

807

818+

58

67

68

59

808

819+

59

68

69

60

809

820+

60

69

70

61

810

821+

61

70

71

62

811

822+

62

71

72

63

812

823+

63

72

117

115

813

824+

116

118

73

64

816

827+

64

73

74

65

815

826+

65

74

75

66

817

828+

66

75

76

67

818

829+

67

76

77

68

819

830+

68

77

78

69

820

831+

69

78

79

70

821

832+

70

79

80

71

822

833+

71

80

81

72

823

834+

72

81

119

117

824

835+

118

120

91

73

827

838+

73

91

92

74

826

837+

74

92

93

75

828

839+

75

93

94

76

829

840+

76

94

95

77

830

841+

77

95

96

78

831

842+

78

96

97

79

832

843+

OptiStruct 13.0 Reference Guide 1497


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

698
845
699
846
700
847
701
850
702
853
703
855
704
857
705
859
706
861
707
863
708
865
709
867
710
869
711
870
712
872
713
873
714
874
715
875
716
876
717
877
718
878
719
879
720
880
721
881
722
883
723
884
724
885
725
886
726
887
727
888
728
889
729
890
730
891
731
892
732

1
834
1
835
1
836
1
849
1
852
1
854
1
856
1
858
1
860
1
862
1
864
1
866
1
868
1
850
1
853
1
855
1
857
1
859
1
861
1
863
1
865
1
867
1
869
1
870
1
872
1
873
1
874
1
875
1
876
1
877
1
878
1
879
1
880
1
881
1

79

97

98

80

833

844+

80

98

99

81

834

845+

81

99

121

119

835

846+

727

730

729

728

848

851+

728

729

732

731

849

850+

731

732

734

733

852

853+

733

734

736

735

854

855+

735

736

738

737

856

857+

737

738

740

739

858

859+

739

740

742

741

860

861+

741

742

744

743

862

863+

743

744

746

745

864

865+

745

746

748

747

866

867+

730

750

749

729

851

871+

729

749

751

732

850

870+

732

751

752

734

853

872+

734

752

753

736

855

873+

736

753

754

738

857

874+

738

754

755

740

859

875+

740

755

756

742

861

876+

742

756

757

744

863

877+

744

757

758

746

865

878+

746

758

759

748

867

879+

750

761

760

749

871

882+

749

760

762

751

870

881+

751

762

763

752

872

883+

752

763

764

753

873

884+

753

764

765

754

874

885+

754

765

766

755

875

886+

755

766

767

756

876

887+

756

767

768

757

877

888+

757

768

769

758

878

889+

758

769

770

759

879

890+

761

772

771

760

882

893+

760

771

773

762

881

892+

1498 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

894
733
895
734
896
735
897
736
898
737
899
738
900
739
901
740
902
741
903
742
905
743
906
744
907
745
908
746
909
747
910
748
911
749
912
750
913
751
914
752
916
753
917
754
918
755
919
756
920
757
921
758
922
759
923
760
924
761
925
762
927
763
928
764
929
765
930
766
931

Altair Engineering

883
1
884
1
885
1
886
1
887
1
888
1
889
1
890
1
891
1
892
1
894
1
895
1
896
1
897
1
898
1
899
1
900
1
901
1
902
1
903
1
905
1
906
1
907
1
908
1
909
1
910
1
911
1
912
1
913
1
914
1
916
1
917
1
918
1
919
1
920

762

773

774

763

883

894+

763

774

775

764

884

895+

764

775

776

765

885

896+

765

776

777

766

886

897+

766

777

778

767

887

898+

767

778

779

768

888

899+

768

779

780

769

889

900+

769

780

781

770

890

901+

772

783

782

771

893

904+

771

782

784

773

892

903+

773

784

785

774

894

905+

774

785

786

775

895

906+

775

786

787

776

896

907+

776

787

788

777

897

908+

777

788

789

778

898

909+

778

789

790

779

899

910+

779

790

791

780

900

911+

780

791

792

781

901

912+

783

794

793

782

904

915+

782

793

795

784

903

914+

784

795

796

785

905

916+

785

796

797

786

906

917+

786

797

798

787

907

918+

787

798

799

788

908

919+

788

799

800

789

909

920+

789

800

801

790

910

921+

790

801

802

791

911

922+

791

802

803

792

912

923+

794

805

804

793

915

926+

793

804

806

795

914

925+

795

806

807

796

916

927+

796

807

808

797

917

928+

797

808

809

798

918

929+

798

809

810

799

919

930+

OptiStruct 13.0 Reference Guide 1499


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

767
932
768
933
769
934
770
935
771
936
772
938
773
939
774
940
775
941
776
942
777
943
778
944
779
945
780
946
781
947
782
949
783
950
784
951
785
952
786
953
787
954
788
955
789
956
790
957
791
958
792
960
793
961
794
962
795
963
796
964
797
965
798
966
799
967
800
968
801

1
921
1
922
1
923
1
924
1
925
1
927
1
928
1
929
1
930
1
931
1
932
1
933
1
934
1
935
1
936
1
938
1
939
1
940
1
941
1
942
1
943
1
944
1
945
1
946
1
947
1
949
1
950
1
951
1
952
1
953
1
954
1
955
1
956
1
957
1

799

810

811

800

920

931+

800

811

812

801

921

932+

801

812

813

802

922

933+

802

813

814

803

923

934+

805

816

815

804

926

937+

804

815

817

806

925

936+

806

817

818

807

927

938+

807

818

819

808

928

939+

808

819

820

809

929

940+

809

820

821

810

930

941+

810

821

822

811

931

942+

811

822

823

812

932

943+

812

823

824

813

933

944+

813

824

825

814

934

945+

816

827

826

815

937

948+

815

826

828

817

936

947+

817

828

829

818

938

949+

818

829

830

819

939

950+

819

830

831

820

940

951+

820

831

832

821

941

952+

821

832

833

822

942

953+

822

833

834

823

943

954+

823

834

835

824

944

955+

824

835

836

825

945

956+

827

838

837

826

948

959+

826

837

839

828

947

958+

828

839

840

829

949

960+

829

840

841

830

950

961+

830

841

842

831

951

962+

831

842

843

832

952

963+

832

843

844

833

953

964+

833

844

845

834

954

965+

834

845

846

835

955

966+

835

846

847

836

956

967+

848

851

850

849

969

972+

1500 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

971
802
974
803
976
804
978
805
980
806
982
807
984
808
986
809
988
810
990
811
991
812
993
813
994
814
995
815
996
816
997
817
998
818
999
819
1000
820
1001
821
1002
822
1004
823
1005
824
1006
825
1007
826
1008
827
1009
828
1010
829
1011
830
1012
831
1013
832
1015
833
1016
834
1017
835
1018

Altair Engineering

970
1
973
1
975
1
977
1
979
1
981
1
983
1
985
1
987
1
989
1
971
1
974
1
976
1
978
1
980
1
982
1
984
1
986
1
988
1
990
1
991
1
993
1
994
1
995
1
996
1
997
1
998
1
999
1
1000
1
1001
1
1002
1
1004
1
1005
1
1006
1
1007

849

850

853

852

970

971+

852

853

855

854

973

974+

854

855

857

856

975

976+

856

857

859

858

977

978+

858

859

861

860

979

980+

860

861

863

862

981

982+

862

863

865

864

983

984+

864

865

867

866

985

986+

866

867

869

868

987

988+

851

871

870

850

972

992+

850

870

872

853

971

991+

853

872

873

855

974

993+

855

873

874

857

976

994+

857

874

875

859

978

995+

859

875

876

861

980

996+

861

876

877

863

982

997+

863

877

878

865

984

998+

865

878

879

867

986

999+

867

879

880

869

988

1000+

871

882

881

870

992

1003+

870

881

883

872

991

1002+

872

883

884

873

993

1004+

873

884

885

874

994

1005+

874

885

886

875

995

1006+

875

886

887

876

996

1007+

876

887

888

877

997

1008+

877

888

889

878

998

1009+

878

889

890

879

999

1010+

879

890

891

880

1000

1011+

882

893

892

881

1003

1014+

881

892

894

883

1002

1013+

883

894

895

884

1004

1015+

884

895

896

885

1005

1016+

885

896

897

886

1006

1017+

OptiStruct 13.0 Reference Guide 1501


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

836
1019
837
1020
838
1021
839
1022
840
1023
841
1024
842
1026
843
1027
844
1028
845
1029
846
1030
847
1031
848
1032
849
1033
850
1034
851
1035
852
1037
853
1038
854
1039
855
1040
856
1041
857
1042
858
1043
859
1044
860
1045
861
1046
862
1048
863
1049
864
1050
865
1051
866
1052
867
1053
868
1054
869
1055
870

1
1008
1
1009
1
1010
1
1011
1
1012
1
1013
1
1015
1
1016
1
1017
1
1018
1
1019
1
1020
1
1021
1
1022
1
1023
1
1024
1
1026
1
1027
1
1028
1
1029
1
1030
1
1031
1
1032
1
1033
1
1034
1
1035
1
1037
1
1038
1
1039
1
1040
1
1041
1
1042
1
1043
1
1044
1

886

897

898

887

1007

1018+

887

898

899

888

1008

1019+

888

899

900

889

1009

1020+

889

900

901

890

1010

1021+

890

901

902

891

1011

1022+

893

904

903

892

1014

1025+

892

903

905

894

1013

1024+

894

905

906

895

1015

1026+

895

906

907

896

1016

1027+

896

907

908

897

1017

1028+

897

908

909

898

1018

1029+

898

909

910

899

1019

1030+

899

910

911

900

1020

1031+

900

911

912

901

1021

1032+

901

912

913

902

1022

1033+

904

915

914

903

1025

1036+

903

914

916

905

1024

1035+

905

916

917

906

1026

1037+

906

917

918

907

1027

1038+

907

918

919

908

1028

1039+

908

919

920

909

1029

1040+

909

920

921

910

1030

1041+

910

921

922

911

1031

1042+

911

922

923

912

1032

1043+

912

923

924

913

1033

1044+

915

926

925

914

1036

1047+

914

925

927

916

1035

1046+

916

927

928

917

1037

1048+

917

928

929

918

1038

1049+

918

929

930

919

1039

1050+

919

930

931

920

1040

1051+

920

931

932

921

1041

1052+

921

932

933

922

1042

1053+

922

933

934

923

1043

1054+

923

934

935

924

1044

1055+

1502 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1056
871
1057
872
1059
873
1060
874
1061
875
1062
876
1063
877
1064
878
1065
879
1066
880
1067
881
1068
882
1070
883
1071
884
1072
885
1073
886
1074
887
1075
888
1076
889
1077
890
1078
891
1079
892
1081
893
1082
894
1083
895
1084
896
1085
897
1086
898
1087
899
1088
900
1089
901
1092
902
1095
903
1097
904
1099

Altair Engineering

1045
1
1046
1
1048
1
1049
1
1050
1
1051
1
1052
1
1053
1
1054
1
1055
1
1056
1
1057
1
1059
1
1060
1
1061
1
1062
1
1063
1
1064
1
1065
1
1066
1
1067
1
1068
1
1070
1
1071
1
1072
1
1073
1
1074
1
1075
1
1076
1
1077
1
1078
1
1091
1
1094
1
1096
1
1098

926

937

936

925

1047

1058+

925

936

938

927

1046

1057+

927

938

939

928

1048

1059+

928

939

940

929

1049

1060+

929

940

941

930

1050

1061+

930

941

942

931

1051

1062+

931

942

943

932

1052

1063+

932

943

944

933

1053

1064+

933

944

945

934

1054

1065+

934

945

946

935

1055

1066+

937

948

947

936

1058

1069+

936

947

949

938

1057

1068+

938

949

950

939

1059

1070+

939

950

951

940

1060

1071+

940

951

952

941

1061

1072+

941

952

953

942

1062

1073+

942

953

954

943

1063

1074+

943

954

955

944

1064

1075+

944

955

956

945

1065

1076+

945

956

957

946

1066

1077+

948

959

958

947

1069

1080+

947

958

960

949

1068

1079+

949

960

961

950

1070

1081+

950

961

962

951

1071

1082+

951

962

963

952

1072

1083+

952

963

964

953

1073

1084+

953

964

965

954

1074

1085+

954

965

966

955

1075

1086+

955

966

967

956

1076

1087+

956

967

968

957

1077

1088+

969

972

971

970

1090

1093+

970

971

974

973

1091

1092+

973

974

976

975

1094

1095+

975

976

978

977

1096

1097+

OptiStruct 13.0 Reference Guide 1503


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

905
1101
906
1103
907
1105
908
1107
909
1109
910
1111
911
1112
912
1114
913
1115
914
1116
915
1117
916
1118
917
1119
918
1120
919
1121
920
1122
921
1123
922
1125
923
1126
924
1127
925
1128
926
1129
927
1130
928
1131
929
1132
930
1133
931
1134
932
1136
933
1137
934
1138
935
1139
936
1140
937
1141
938
1142
939

1
1100
1
1102
1
1104
1
1106
1
1108
1
1110
1
1092
1
1095
1
1097
1
1099
1
1101
1
1103
1
1105
1
1107
1
1109
1
1111
1
1112
1
1114
1
1115
1
1116
1
1117
1
1118
1
1119
1
1120
1
1121
1
1122
1
1123
1
1125
1
1126
1
1127
1
1128
1
1129
1
1130
1
1131
1

977

978

980

979

1098

1099+

979

980

982

981

1100

1101+

981

982

984

983

1102

1103+

983

984

986

985

1104

1105+

985

986

988

987

1106

1107+

987

988

990

989

1108

1109+

972

992

991

971

1093

1113+

971

991

993

974

1092

1112+

974

993

994

976

1095

1114+

976

994

995

978

1097

1115+

978

995

996

980

1099

1116+

980

996

997

982

1101

1117+

982

997

998

984

1103

1118+

984

998

999

986

1105

1119+

986

999

1000

988

1107

1120+

988

1000

1001

990

1109

1121+

992

1003

1002

991

1113

1124+

991

1002

1004

993

1112

1123+

993

1004

1005

994

1114

1125+

994

1005

1006

995

1115

1126+

995

1006

1007

996

1116

1127+

996

1007

1008

997

1117

1128+

997

1008

1009

998

1118

1129+

998

1009

1010

999

1119

1130+

999

1010

1011

1000

1120

1131+

1000

1011

1012

1001

1121

1132+

1003

1014

1013

1002

1124

1135+

1002

1013

1015

1004

1123

1134+

1004

1015

1016

1005

1125

1136+

1005

1016

1017

1006

1126

1137+

1006

1017

1018

1007

1127

1138+

1007

1018

1019

1008

1128

1139+

1008

1019

1020

1009

1129

1140+

1009

1020

1021

1010

1130

1141+

1010

1021

1022

1011

1131

1142+

1504 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1143
940
1144
941
1145
942
1147
943
1148
944
1149
945
1150
946
1151
947
1152
948
1153
949
1154
950
1155
951
1156
952
1158
953
1159
954
1160
955
1161
956
1162
957
1163
958
1164
959
1165
960
1166
961
1167
962
1169
963
1170
964
1171
965
1172
966
1173
967
1174
968
1175
969
1176
970
1177
971
1178
972
1180
973
1181

Altair Engineering

1132
1
1133
1
1134
1
1136
1
1137
1
1138
1
1139
1
1140
1
1141
1
1142
1
1143
1
1144
1
1145
1
1147
1
1148
1
1149
1
1150
1
1151
1
1152
1
1153
1
1154
1
1155
1
1156
1
1158
1
1159
1
1160
1
1161
1
1162
1
1163
1
1164
1
1165
1
1166
1
1167
1
1169
1
1170

1011

1022

1023

1012

1132

1143+

1014

1025

1024

1013

1135

1146+

1013

1024

1026

1015

1134

1145+

1015

1026

1027

1016

1136

1147+

1016

1027

1028

1017

1137

1148+

1017

1028

1029

1018

1138

1149+

1018

1029

1030

1019

1139

1150+

1019

1030

1031

1020

1140

1151+

1020

1031

1032

1021

1141

1152+

1021

1032

1033

1022

1142

1153+

1022

1033

1034

1023

1143

1154+

1025

1036

1035

1024

1146

1157+

1024

1035

1037

1026

1145

1156+

1026

1037

1038

1027

1147

1158+

1027

1038

1039

1028

1148

1159+

1028

1039

1040

1029

1149

1160+

1029

1040

1041

1030

1150

1161+

1030

1041

1042

1031

1151

1162+

1031

1042

1043

1032

1152

1163+

1032

1043

1044

1033

1153

1164+

1033

1044

1045

1034

1154

1165+

1036

1047

1046

1035

1157

1168+

1035

1046

1048

1037

1156

1167+

1037

1048

1049

1038

1158

1169+

1038

1049

1050

1039

1159

1170+

1039

1050

1051

1040

1160

1171+

1040

1051

1052

1041

1161

1172+

1041

1052

1053

1042

1162

1173+

1042

1053

1054

1043

1163

1174+

1043

1054

1055

1044

1164

1175+

1044

1055

1056

1045

1165

1176+

1047

1058

1057

1046

1168

1179+

1046

1057

1059

1048

1167

1178+

1048

1059

1060

1049

1169

1180+

OptiStruct 13.0 Reference Guide 1505


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA

974
1182
975
1183
976
1184
977
1185
978
1186
979
1187
980
1188
981
1189
982
1191
983
1192
984
1193
985
1194
986
1195
987
1196
988
1197
989
1198
990
1199
991
1200
992
1202
993
1203
994
1204
995
1205
996
1206
997
1207
998
1208
999
1209
1000
1210
1001
1213
1002
1216
1003
1218
1004
1220
1005
1222
1006
1224
1007
1226
1008

1
1171
1
1172
1
1173
1
1174
1
1175
1
1176
1
1177
1
1178
1
1180
1
1181
1
1182
1
1183
1
1184
1
1185
1
1186
1
1187
1
1188
1
1189
1
1191
1
1192
1
1193
1
1194
1
1195
1
1196
1
1197
1
1198
1
1199
1
1212
1
1215
1
1217
1
1219
1
1221
1
1223
1
1225
1

1049

1060

1061

1050

1170

1181+

1050

1061

1062

1051

1171

1182+

1051

1062

1063

1052

1172

1183+

1052

1063

1064

1053

1173

1184+

1053

1064

1065

1054

1174

1185+

1054

1065

1066

1055

1175

1186+

1055

1066

1067

1056

1176

1187+

1058

1069

1068

1057

1179

1190+

1057

1068

1070

1059

1178

1189+

1059

1070

1071

1060

1180

1191+

1060

1071

1072

1061

1181

1192+

1061

1072

1073

1062

1182

1193+

1062

1073

1074

1063

1183

1194+

1063

1074

1075

1064

1184

1195+

1064

1075

1076

1065

1185

1196+

1065

1076

1077

1066

1186

1197+

1066

1077

1078

1067

1187

1198+

1069

1080

1079

1068

1190

1201+

1068

1079

1081

1070

1189

1200+

1070

1081

1082

1071

1191

1202+

1071

1082

1083

1072

1192

1203+

1072

1083

1084

1073

1193

1204+

1073

1084

1085

1074

1194

1205+

1074

1085

1086

1075

1195

1206+

1075

1086

1087

1076

1196

1207+

1076

1087

1088

1077

1197

1208+

1077

1088

1089

1078

1198

1209+

1090

1093

1092

1091

1211

1214+

1091

1092

1095

1094

1212

1213+

1094

1095

1097

1096

1215

1216+

1096

1097

1099

1098

1217

1218+

1098

1099

1101

1100

1219

1220+

1100

1101

1103

1102

1221

1222+

1102

1103

1105

1104

1223

1224+

1104

1105

1107

1106

1225

1226+

1506 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1228
1009
1230
1010
1232
1011
1233
1012
1235
1013
1236
1014
1237
1015
1238
1016
1239
1017
1240
1018
1241
1019
1242
1020
1243
1021
1244
1022
1246
1023
1247
1024
1248
1025
1249
1026
1250
1027
1251
1028
1252
1029
1253
1030
1254
1031
1255
1032
1257
1033
1258
1034
1259
1035
1260
1036
1261
1037
1262
1038
1263
1039
1264
1040
1265
1041
1266
1042
1268

Altair Engineering

1227
1
1229
1
1231
1
1213
1
1216
1
1218
1
1220
1
1222
1
1224
1
1226
1
1228
1
1230
1
1232
1
1233
1
1235
1
1236
1
1237
1
1238
1
1239
1
1240
1
1241
1
1242
1
1243
1
1244
1
1246
1
1247
1
1248
1
1249
1
1250
1
1251
1
1252
1
1253
1
1254
1
1255
1
1257

1106

1107

1109

1108

1227

1228+

1108

1109

1111

1110

1229

1230+

1093

1113

1112

1092

1214

1234+

1092

1112

1114

1095

1213

1233+

1095

1114

1115

1097

1216

1235+

1097

1115

1116

1099

1218

1236+

1099

1116

1117

1101

1220

1237+

1101

1117

1118

1103

1222

1238+

1103

1118

1119

1105

1224

1239+

1105

1119

1120

1107

1226

1240+

1107

1120

1121

1109

1228

1241+

1109

1121

1122

1111

1230

1242+

1113

1124

1123

1112

1234

1245+

1112

1123

1125

1114

1233

1244+

1114

1125

1126

1115

1235

1246+

1115

1126

1127

1116

1236

1247+

1116

1127

1128

1117

1237

1248+

1117

1128

1129

1118

1238

1249+

1118

1129

1130

1119

1239

1250+

1119

1130

1131

1120

1240

1251+

1120

1131

1132

1121

1241

1252+

1121

1132

1133

1122

1242

1253+

1124

1135

1134

1123

1245

1256+

1123

1134

1136

1125

1244

1255+

1125

1136

1137

1126

1246

1257+

1126

1137

1138

1127

1247

1258+

1127

1138

1139

1128

1248

1259+

1128

1139

1140

1129

1249

1260+

1129

1140

1141

1130

1250

1261+

1130

1141

1142

1131

1251

1262+

1131

1142

1143

1132

1252

1263+

1132

1143

1144

1133

1253

1264+

1135

1146

1145

1134

1256

1267+

1134

1145

1147

1136

1255

1266+

OptiStruct 13.0 Reference Guide 1507


Proprietary Information of Altair Engineering

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1043
1269
1044
1270
1045
1271
1046
1272
1047
1273
1048
1274
1049
1275
1050
1276
1051
1277
1052
1279
1053
1280
1054
1281
1055
1282

1
1258
1
1259
1
1260
1
1261
1
1262
1
1263
1
1264
1
1265
1
1266
1
1268
1
1269
1
1270
1
1271

1136

1147

1148

1137

1257

1268+

1137

1148

1149

1138

1258

1269+

1138

1149

1150

1139

1259

1270+

1139

1150

1151

1140

1260

1271+

1140

1151

1152

1141

1261

1272+

1141

1152

1153

1142

1262

1273+

1142

1153

1154

1143

1263

1274+

1143

1154

1155

1144

1264

1275+

1146

1157

1156

1145

1267

1278+

1145

1156

1158

1147

1266

1277+

1147

1158

1159

1148

1268

1279+

1148

1159

1160

1149

1269

1280+

1149

1160

1161

1150

1270

1281+

CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+
CHEXA
+

1057
1284
1058
1285
1059
1286
1060
1287
1061
1288
1062
1290
1063
1291
1064
1292
1065
1293
1066
1294
1067
1295
1068
1296
1069
1297
1070
1298
1071
1299
1072
1301
1073
1302
1074
1303
1075
1304
1076
1305
1077
1306

1
1273
1
1274
1
1275
1
1276
1
1277
1
1279
1
1280
1
1281
1
1282
1
1283
1
1284
1
1285
1
1286
1
1287
1
1288
1
1290
1
1291
1
1292
1
1293
1
1294
1
1295

1151

1162

1163

1152

1272

1283+

1152

1163

1164

1153

1273

1284+

1153

1164

1165

1154

1274

1285+

1154

1165

1166

1155

1275

1286+

1157

1168

1167

1156

1278

1289+

1156

1167

1169

1158

1277

1288+

1158

1169

1170

1159

1279

1290+

1159

1170

1171

1160

1280

1291+

1160

1171

1172

1161

1281

1292+

1161

1172

1173

1162

1282

1293+

1162

1173

1174

1163

1283

1294+

1163

1174

1175

1164

1284

1295+

1164

1175

1176

1165

1285

1296+

1165

1176

1177

1166

1286

1297+

1168

1179

1178

1167

1289

1300+

1167

1178

1180

1169

1288

1299+

1169

1180

1181

1170

1290

1301+

1170

1181

1182

1171

1291

1302+

1171

1182

1183

1172

1292

1303+

1172

1183

1184

1173

1293

1304+

1173

1184

1185

1174

1294

1305+

1508 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA
1078
1
1174
1185
1186
1175
1295
1306+
+
1307
1296
CHEXA
1079
1
1175
1186
1187
1176
1296
1307+
+
1308
1297
CHEXA
1080
1
1176
1187
1188
1177
1297
1308+
+
1309
1298
CHEXA
1081
1
1179
1190
1189
1178
1300
1311+
+
1310
1299
CHEXA
1082
1
1178
1189
1191
1180
1299
1310+
+
1312
1301
CHEXA
1083
1
1180
1191
1192
1181
1301
1312+
+
1313
1302
CHEXA
1084
1
1181
1192
1193
1182
1302
1313+
+
1314
1303
CHEXA
1085
1
1182
1193
1194
1183
1303
1314+
+
1315
1304
CHEXA
1086
1
1183
1194
1195
1184
1304
1315+
+
1316
1305
CHEXA
1087
1
1184
1195
1196
1185
1305
1316+
+
1317
1306
CHEXA
1088
1
1185
1196
1197
1186
1306
1317+
+
1318
1307
CHEXA
1089
1
1186
1197
1198
1187
1307
1318+
+
1319
1308
CHEXA
1090
1
1187
1198
1199
1188
1308
1319+
+
1320
1309
CHEXA
1091
1
1190
1201
1200
1189
1311
1322+
+
1321
1310
CHEXA
1092
1
1189
1200
1202
1191
1310
1321+
+
1323
1312
CHEXA
1093
1
1191
1202
1203
1192
1312
1323+
+
1324
1313
CHEXA
1094
1
1192
1203
1204
1193
1313
1324+
+
1325
1314
CHEXA
1095
1
1193
1204
1205
1194
1314
1325+
+
1326
1315
CHEXA
1096
1
1194
1205
1206
1195
1315
1326+
+
1327
1316
CHEXA
1097
1
1195
1206
1207
1196
1316
1327+
+
1328
1317
CHEXA
1098
1
1196
1207
1208
1197
1317
1328+
+
1329
1318
CHEXA
1099
1
1197
1208
1209
1198
1318
1329+
+
1330
1319
CHEXA
1100
1
1198
1209
1210
1199
1319
1330+
+
1331
1320
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name information for generic property collectors
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Property Definition for 1-D Elements
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name and color information for generic components
$
$$------------------------------------------------------------------------------$
$HMNAME COMP
6"auto1"
$HWCOLOR COMP
6
3
$
$$
$$------------------------------------------------------------------------------$
$$
Property Definition for Surface and Volume Elements
$
$$------------------------------------------------------------------------------$
$$
$$ PSHELL Data
$
$HMNAME COMP
4"shells"

Altair Engineering

OptiStruct 13.0 Reference Guide 1509


Proprietary Information of Altair Engineering

$HWCOLOR COMP
4
7
PSHELL
4
20.2
2
2
$$
$$ PSOLID Data
$
$HMNAME COMP
1"solids"
$HWCOLOR COMP
1
26
PSOLID
1
1
PFLUID
PSOLID
2
2
$$
$$------------------------------------------------------------------------------$
$$
Material Definition Cards
$
$$------------------------------------------------------------------------------$
$$-------------------------------------------------------------$$ HYPERMESH TAGS
$$-------------------------------------------------------------$$BEGIN TAGS
$$END TAGS
$$
$$ MAT1 Data
$
$HMNAME MAT
2"MAT1"
$HWCOLOR MAT
2
18
MAT1
2200000.0
0.3
0.9e-5
$$
$$
$$ MAT10 Data
$HMNAME MAT
1"MAT10_1"
$HWCOLOR MAT
1
3
MAT10
11.0
0.01
$$
$$
$$------------------------------------------------------------------------------$
$$
HyperMesh name information for generic materials
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Material Definition Cards
$
$$------------------------------------------------------------------------------$
$$
$$------------------------------------------------------------------------------$
$$
Loads and Boundary Conditions
$
$$------------------------------------------------------------------------------$
$$
$$HyperMesh name and color information for generic loadcollectors
$$
$HMNAME LOADCOL
4"SPC"
$HWCOLOR LOADCOL
4
3
$
$HMNAME LOADCOL
6"spcd"
$HWCOLOR LOADCOL
6
4
$
$$
$$
$$
$$
$$ FREQ1 cards
$$
$HMNAME LOADCOL
5"freq"
$HWCOLOR LOADCOL
5
4
FREQ1
50.1
10.0
5
$$
$$
$$
$$
$$
$$ RLOAD2 cards
$$
$HMNAME LOADCOL
2"rload2"

1510 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$HWCOLOR LOADCOL
RLOAD2
2
6
$$
$HMNAME LOADCOL
$HWCOLOR LOADCOL
RLOAD2
3
3
$$
$$
$$
$$ TABLED1 cards
$$
$HMNAME LOADCOL
$HWCOLOR LOADCOL
TABLED1
1 LINEAR
+
0.0
0.0
$$
TABLED1
2 LINEAR
+
0.0
0.0
$$
TABLED1
3 LINEAR
+
0.0
5.0
$$ DLOAD cards
$$
$HMNAME LOADCOL
$HWCOLOR LOADCOL
DLOAD
111.0
$$
$$
$$
$$
$$
$$
$$
$$ SPC Data
$$
SPC
4
1431
SPC
4
1432
SPC
4
1451
SPC
4
1452
SPC
4
1734
$$
$$ SPCD Data
$$
SPCD
6
1734
$
$ DAREA Data
$
$$
$$ DAREA Data
$$
DAREA
3
1734
ENDDATA

5
1

ACCE

LOAD

1.0

3"darea"
3
5

1"tab"
1
41
LINEAR
1000.0
1.0ENDT
LINEAR
1000.0

1.0ENDT

LINEAR
1000.0

5.0ENDT

11"DLOAD11"
11
3
1.0
2

1234560.0
1234560.0
1234560.0
1234560.0
3
0.0

3.0

3-10.0

ALTDOCTAG "HqTD_ARNMI\S\pMpN13G;5oANN]l[enE7fmSbTJro20LOpNriZFOQfUk]
_`5hfS5ATf6pT7RXMjA3e@k_r^K?GP;?OeEbD0"
ADI0.1.0 2011-05-13T19:57:45 0of1 OSQA
ENDDOCTAG

Altair Engineering

OptiStruct 13.0 Reference Guide 1511


Proprietary Information of Altair Engineering

Comments
1.

PACABS is referenced by a CHACAB entry only.

2.

If SYNTH = YES, then TID1 and TID2 must be supplied (TID3 is optional) and the
equivalent structural model will be derived from tables TIDi. If TID3 is blank, then the
weighting function defaults to 1.0.

3.

If SYNTH=NO, then the equivalent structural model will be derived from B, K and M.

4.

This card is represented as a property in HyperMesh.

1512 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PANEL
Bulk Data Entry
PANEL Panel Definition for Panel Participation Output
Description
Defines up to four sets of grid points or elements as panels for panel participation output for a
frequency response analysis of a coupled fluid-structural model.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PANEL

NAME1

SID1

NAME2

SID2

NAME3

SID3

NAME4

SID4

Field

Contents

NAME#

Panel label.

(10)

No default (Character string)


SID#

Set identification number for a set of grids or elements.


No default (Integer > 0)

Comments
1.

If a set of elements is defined, the panel will consist of all grid points connected to these
elements.

Altair Engineering

OptiStruct 13.0 Reference Guide 1513


Proprietary Information of Altair Engineering

PANELG
Bulk Data Entry
PANELG Generic Panel Definition
Description
Defines a set of grid points and/or elements as generic panel.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PANELG

ID

NAME

TYPE

ESID

GSID

Field

Contents

ID

Unique panel identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


NAME

Panel label.
No default (Character string)

TYPE

Panel type.
Default = blank (PFP, ERP, SOUND, or blank, See comment 1)

ESID

Set identification number for a set of elements.


No default (Integer > 0 or blank)

GSID

Set identification number for a set of grids.


No default (Integer > 0 or blank)

Comments
1.

The panel type indicates the context in which the panel should be used. PFP indicates
that the panel should be considered for panel participation output (similar to PANEL). ERP
indicates that the panel should be considered for equivalent radiated power output

1514 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(similar to ERPPNL). SOUND indicates that the panel should be considered for radiated
sound output. Blank indicates that the panel should be considered in any context
involving panels.
2.

Panels of type ERP/SOUND (or blank) may be defined as a set of elements, a set of grid
points, or both. If a set of elements is defined, the panel will consist of all grid points
connected to these elements. If both sets are defined, the panel will consist of the
intersection of those sets.

3.

Panels of type PFP must be defined as a set of grid points exclusively.

4.

The element set can also consist of solid elements. In such cases, grids on the wetted
surface are automatically detected to define the panel.

Altair Engineering

OptiStruct 13.0 Reference Guide 1515


Proprietary Information of Altair Engineering

PARAM
Bulk Data Entry
PARAM Solution Control Parameter
Description
Defines values for parameters used during analysis and optimization.
Format
(1)

(2)

(3)

PARAM

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

PARAM

C OUPMASS

YES

Field

Contents

Name of Parameter.

Value of Parameter.

(4)

(5)

(6)

(7)

(8)

(9)

(10)

The available parameters and their values are listed below (click the parameter name for
parameter descriptions).

Parameter

Description

Values

ACMODL12

Used to restore the ACMODL formulation used in


version 12.0 and earlier for the Fluid-Structure
Interface.

YES, NO
Default = NO

AGGPCH

To support output of the fluid-structure coupling


matrix to the Punch (.pch) file as a matrix defined

YES, NO

1516 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Description

Values

using DMIG data entry.

Default = NO

AKUSMOD

Use external fluid-structure coupling matrix


generated by AKUSMOD.

YES, NO
Default = NO

ALPHA1

Adds Rayleigh damping to viscous damping for


structural mesh.

<REAL>
Default = 0.0

ALPHA2

Adds Rayleigh damping to viscous damping for


structural mesh.

<REAL>
Default = 0.0

ALPHA1FL

Adds Rayleigh damping to viscous damping for fluid


mesh.

<REAL>
Default = 0.0

ALPHA2FL

Adds Rayleigh damping to viscous damping for fluid


mesh.

<REAL>
Default = 0.0

AMLS

Use external AMLS eigenvalue solver.

YES, NO
Default = NO

AMLSMAXR

Used to determine singularities in the stiffness matrix <REAL>


for AMLS eigenvalue solver.
Default = 1.0e-8

AMLSMEM

Defines the amount of memory in Gigabytes to be


used by the external AMLS eigenvalue solver.

<REAL>
No default

AMLSNCPU

Identify number of cpu's to be used by AMLS


eigenvalue solver.

1, 2, 4
Default = no. of cpus
used by the solver

AMLSUCON

Constrain unconnected grids for AMLS eigenvalue


solver.

1, 0
Default = 0

AMSESLM

Indicate if the AMSES numerical mode for enforced


motion based modal dynamic analysis with large
mass method will be activated or not.

<YES, NO>
Default = NO

ASCOUP

Generates the fluid-structure coupling (area) matrix


for use in the solution.

<YES, NO>
Default = YES

AUTOMSET

Automatically convert dependent degrees-of-

<YES, NO>

Altair Engineering

OptiStruct 13.0 Reference Guide 1517


Proprietary Information of Altair Engineering

Parameter

Description

Values

freedom of rigid elements to independent degreesof-freedom.

Default = YES

AUTOSPC

Automatically constrain degrees-of-freedom with no


stiffness.

YES, NO
Default = YES

AUTOSPRT

Activate inertia relief and auto-support degree-offreedom generation.

1, 0
Default = 1

BUSHRLMT

Issues a WARNING when the stiffness value for


rotational components on the PBUSH entry exceeds
the specified limit (BUSHRLMT).

<Real Number > 0.0>


Default = 1.0E+09

BUSHSTIF

Specifies a value to replace large stiffness values


(>1.0E+07) input in field K of the PBUSH data entry.

<Real Number > 0.0>


No default

BUSHTLMT

Issues a WARNING when the stiffness value for


translational components on the PBUSH entry
exceeds the specified limit (BUSHTLMT).

<Real Number > 0.0>


Default = 1E+07

CB2

Scale factor for direct input damping matrices.

Real
Default = 1.0

CHECKEL

Activate element quality checking.

NO, YES, FULL


Default = YES

CHECKMAT

Activate material property checking.

YES, NO, FULL


Default = YES

CHKGPDIR

Activate gap direction alignment checking.

YES, NO, WARN,


FULL, REVERSE
Default = YES

CK2

Scale factor for direct input stiffness matrices.

Real
Default = 1.0

CK3

Specifies factors for the stiffness matrix produced


by GENEL cards.

Real
Default = 1.0

CM2

Scale factor for direct input mass matrices.

Real
Default = 1.0

1518 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Description

Values

CMFTINIT

Defines lower threshold for *.HM.comp.cmf and


*.HM.ent.cmf HyperMesh command files.

0.0 < REAL < 1.0


Default = 0.0

CMFTSTEP

Defines step or interval value for *.HM.comp.cmf


and *.HM.ent.cmf HyperMesh command.

0.0 < REAL < 1.0


Default = 0.1

CMSALOD

Controls the inclusion of mass contribution from the


mass matrix stored in the PUNCH DMIG or the H3D
DMIG files for the generation of RFORCE and Gravity
Loads.

<YES, NO>
Default = YES

CMSDIRM

Allows flexible body generation when directional


masses are defined in the input file.

YES, NO
Default = NO

CMSOFST

Consider shell offsets for flexbody generation.

<YES, NO>
Default - NO

COEFFC

Friction coefficient on curvatures for one-step


stamping simulation.

Real > 0.0

COMP2SHL

Results of homogenization of composite properties.

CONTFEL

Activates Contact-friendly elements. This is


recommended when second order solids/gaskets are
used with contact analysis in OptiStruct.

<YES, NO>
Default = NO

COUPMASS

Use coupled mass matrix approach for eigenvalue


analysis.

-1, 0, 1, YES, NO
Default = NO

CP2

Scale factor for direct input load matrices.

Real
Default = 1.0

CSTEVAL

Use wall time based cost evaluation for Lanczos


steps.

<YES, NO>
Default = YES

CSTOL

Specifies how many decimal digits may be lost to


cancellation in one operation during the
eigensolution process.

Real
Default = 3.5

DFREQ

Used to determine duplicate frequencies.

Real

Altair Engineering

YES, NO,
BULK
Default = NO

OptiStruct 13.0 Reference Guide 1519


Proprietary Information of Altair Engineering

Parameter

Description

Values

Default = 10-5
DISIFMCK

Skip indefinite mass matrix check.

<YES, NO>
Default = NO

DISJOINT

Used to allow AMLS to handle disconnected parts.


This can also be accomplished with
PARAM,AMLSUCON.

Integer
Default = NONE

DUPTOL

Level of accuracy used in determining duplicate


grids.

<0, 1, 2, 3, 4, 5>
Default = 0

EFFMAS

Output modal participation factors and effective


mass for normal modes analyses.

YES, NO, Integer


Default = NO

EHD

Prints the inverse of the stiffness matrix created by


static reduction to FORTRAN unit 3

<YES,NO>
Default = NO

ELASRLMT

Issues a WARNING when the stiffness value for


rotational components on the CELAS2/4 or PELAS
entry exceeds the specified limit (ELASRLMT).

<Real Number > 0.0>


Default = 1.0E + 09

ELASSTIF

Specifies a value to replace large stiffness values


(>1.0E+07) input in field K of the PELAS data entry.

<Real Number > 0.0>


No default

ELASTLMT

Issues a WARNING when the stiffness value for


translational components on the CELAS2/4 or PELAS
entry exceeds the specified limit (ELASTLMT).

<Real Number > 0.0>


Default = 1E+07

ENFMOTN

Switch between relative and absolute displacement


output in Modal Frequency Response Analysis with
enforced motion.

<REL, ABS>
Default = ABS

ERPC

The speed of sound used in the ERP calculation

Real > 0.0


Default = 1.0

ERPREFDB

The reference value in decibels (dB) used in ERP


calculations.

Real > 0.0


Default = 1.0

ERPRHO

The fluid density used in ERP calculations.

Real > 0.0


Default = 1.0

1520 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Description

Values

ERPRLF

The Radiation Loss Factor used in ERP calculation.

Real > 0.0


Default = 1.0

EXCEXB

Controls the output of the AVL/EXCITE .exb file


directly from OptiStruct.

<YES, BOTH, NO>


Default = BOTH

EXCOUT

Outputs of condensed superelement information for


AVL/EXCITE.

<-1, 0, 1, 3, 4, 5, 6>
Default = 0

EXPERTNL

Activates nonlinear expert system to aid in the


convergence of small displacement nonlinear
problems.

YES, NO
Default = NO

EXTOUT

Output reduced matrices to .pch or .dmg file.

<DMIGPCH, DMIGBIN>
No default

FASTFR

Controls the activation of a faster, alternative


method (FASTFR) for Modal Frequency Response
Analysis.

<YES, NO>
Default = AUTO

FFRS

Used to invoke the external FastFRS (Fast


Frequency Response Solver).

<YES, NO>
Default = NO

FFRSLFREQ

Defines a frequency cut-off value in Hertz used to


partition the structural system into low frequency
and high frequency parts.

Real
Default = 1.0

FFRSMEM

Defines the amount of memory in Gigabytes to be


<Real>
used by the external FastFRS modal equation solver. Default = 2.0 (GB)

FFRSNCPU

Defines the number of cpus to be used by the


external FastFRS solver.

<INTEGER>
Default = number of
cpu's used by
OptiStruct.

FLEXH3D

Generate flexh3d files for flexible bodies in an MBD


analysis.

<AUTO, YES, NO>


Default = AUTO

FLIPOK

Allows tetrahedral elements to invert during shape


optimization.

NO, YES
Default = NO

Altair Engineering

OptiStruct 13.0 Reference Guide 1521


Proprietary Information of Altair Engineering

Parameter

Description

Values

FRIC

Define multiplier for K2PP reference.

<REAL>
Default = 1.0

FZERO

Identify the maximum frequency of a rigid body


mode.

<REAL>
Default = 0.1

Specifies the uniform structural damping coefficient


for dynamic analyses.

<REAL>
Default = 0.0

GE_MOD

Modifies specified GE values.

<REAL> or NO_GE>
No default

GFL

Specifies the uniform fluid damping coefficient for


dynamic analyses.

<REAL>
Default = 0.0

GMAR

Controls the accuracy of the external AMLS


eigenvalue solution.

<REAL>
Default = 1.1

GMAR1

Controls the accuracy of the external AMLS


eigenvalue solution.

<REAL>
Default = 1.7

GPSLOC

Controls where the grid point stresses are calculated Z1, Z2 and MID
for output to the .mnf file.
Default = Z1

GRDPNT

Obsolete NASTRAN parameter that will give


information about the mass properties of the
structure.

<-1, 0>
Default = -1

GRIDFORM

This parameter controls the output format of the


.grid file.

<LONG, SHORT>
Default = SHORT

GYROAVG

Used to select the frequency response analysis


formulation type for rotor dynamics analysis.

<0, -1>
Default = 0

HASHASSM

Enable hash-table based assembly.

<YES, NO>
Default = NO

HFREQ

Specifies the upper bound of the frequency range of


interest for modal combination.

<REAL>
Default = None

HFREQFL

Excludes modes with frequencies greater than

<REAL>

1522 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Description

Values

HFREQFL in Coupled Modal Frequency Response


Analysis (Acoustic Analysis).

(Hertz)

I64SLV

Enforces the activation of internal long (64-bit)


integer sparse direct solver.

<YES, NO>
Default = NO

INREL

Controls the calculation of inertia relief.

0, -1, -2
Default = 0, for static
subcases
Default = -2, for modal
frequency response
subcases

ITAPE

Writes the Tape Label at the beginning of the


OUTPUT2 results file.

-1, 0
Default = -1

INTRFACE

Generates the .interface file to verify if proper


connection has been established between the Fluid
and Structure meshes at the interface.

YES, NO
Default = YES

K4CUTOFF

Sets cut-off value if the low rank representation for


the structural damping matrix is selected.

<REAL>
Default = 0.1

KDAMP

Enter viscous modal damping into the stiffness


matrix as structural damping.

1, -1
Default = 1

KGRGD

Include contributions from rigid elements in the


geometric stiffness matrix.

YES, NO
Default = NO

LFREQ

Can be used to remove the Rigid Body Modes from


the Modal Space.

<REAL>
Default = None

LFREQFL

Excludes modes with frequencies lower than


LFREQFL in Coupled Modal Frequency Response
Analysis (Acoustic Analysis).

<REAL> (Hertz)

LGDISP

Activates Large Displacement Nonlinear Analysis.

<1, 0, -1>
Default = 0

LMSOUT

Output the condensed Flex Body Modes, full Diagonal YES, NO, STRESS
Mass Matrix, and modal stresses to the .op2 file.
Default = NO

Altair Engineering

Default = None

Default = None

OptiStruct 13.0 Reference Guide 1523


Proprietary Information of Altair Engineering

Parameter

Description

Values

LOWRANK

Indicates to FastFRS which solution strategy to use


to handle the modal structural damping matrix.

<0, -1, 1>


Default = 0

MASSDMIG

For static condensation with ASET of a static


loadcase, the reduced stiffness matrix [k] and load
vector {p} are created.

<YES, NO>
Default = NO

MAXDAMP

Identify the maximum number of residual vectors to


be calculated.

<INTEGER>
Default = 400

MBDH3D

Choose the type of the results output to the .h3d


file for MBD analyses.

NODAL, MODAL, BOTH,


NONE
Default = BOTH

MBDREC

Create a small and large flexible body files during


Component Mode Synthesis (CMS).

MEMTRIM

Activate/deactivate the memory-trim feature when


using AMLS eigensolver.

<YES, NO>
Default = YES

MFILTER

Defines a threshold for the mode tracking matrix to


check eigenvector correspondence.

<0.0 < real number <


1.0>

MODETRAK

Track mode numbers by comparing eigenvectors


between iterations.

-1, 0, 1, YES, NO
Default = NO

NEGMASS

Allows run to proceed with negative diagonal mass


terms.

<0, 1>
Default = 0

NLAFILE

Controls the output of animation files (A-File) in


geometric nonlinear analysis.

<YES, NO>
Default = NO

NLFAT

Forces OptiStruct to run models in which fatigue


solutions reference nonlinear quasi-static analysis
(NLSTAT) subcases.

<YES, NO>
Default = NO

YES, NO
Default = NO

This is not recommended; refer to the complete


PARAM, NLFAT documentation for details.
NLRFILE

Controls the output of restart files (R-File) in


geometric nonlinear analysis.

1524 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

<YES, NO>
Default = NO

Altair Engineering

Parameter

Description

NLRUN

Controls the run of geometric nonlinear analysis after <YES, NO>


bulk to block conversion.
Default = YES

NPRBAR

Controls the number of the output INFORMATION


#741 for RBAR element.

<INTEGER>
Default = 3

NPRBE2

Controls the number of the output INFORMATION


#741 for RBE2 element.

<INTEGER>
Default = 3

NPRGDE

Controls the number of the output INFORMATION


#742.

<INTEGER>
Default = 3

NUMEG

Specifies the anticipated number of modes to be


calculated in order to estimate disk space usage.

<INTEGER>
1000

OGEOM

Output model data to the OUTPUT2 results file.

<YES, NO>
Default = YES

OMACHPR

Select newer version of certain OUTPUT2


datablocks.

<YES, NO>
Default = NO

OMID

Output stress and strain results for shell and


membrane elements with reference to the material
coordinate system.

<YES, NO>
Default = NO

OP2GM34

Controls the output of GEOM3 and GEOM4 data


blocks to the .op2 file.

<TRUE, FALSE>
Default = TRUE

PLIGEXT

Print the applied load vector in DMIG form to the


.pligext file.

<YES,NO>
Default = NO

POST

Generate an OUTPUT2 results file.

0, -1, -2, -5
Default = 0

POSTEXT

Output the modal complex stiffness matrix and modal YES, NO


viscous damping matrix to the OUTPUT2 results file. Default = NO

PRESUBNL

Forces OptiStruct to run models in which Linear


Buckling Analysis or Preloaded Analysis is defined, in
conjunction with nonlinear materials (MATS1,
MATHE, or MGASK) or Large Displacement Nonlinear

Altair Engineering

Values

YES, NO
Default = NO

OptiStruct 13.0 Reference Guide 1525


Proprietary Information of Altair Engineering

Parameter

Description

Values

Analysis.
This is not recommended. Refer to the complete
PARAM, PRESUBNL documentation for details.
PRGPST

Output AutoSPC information to the .out file.

<YES, NO>
Default = YES

PRINFACC

Controls the output of inertial relief rigid body forces


and accelerations.

<1, 0>

RBE2FREE

Used to convert ERROR 725 into WARNING 825 when


singular RBE2 elements are present in the model.

<YES, NO>
Default = NO

RBE3FREE

Used to convert ERROR 772 into WARNING 824 when


free spiders on RBE3 elements are present in the
model. These free spiders may contain singular
degrees of freedom.

<YES, NO>
Default = NO

RBMEIG

Defines the cut-off eigenvalue for determining rigid


body modes calculated by AMLS.

<REAL>
Default = 0.1

REANAL

Reanalyze the final iteration of a topology


optimization without penalization.

0.0 < REAL < 1.0


No default

RECOVER

Allows you to request full-structure mode shape


output instead of the modes of the condensed
system generated during Component Mode Synthesis
(CMS) within the specified range of frequencies.

<LB, UB>
Default for LB = 0.0,
and UB must be
specified

RENUMOK

Allows you to correctly renumber the reversed (but


acceptable) sequence of element grids without
having to run (import and re-export) the model
through HyperMesh.

<YES, NO, BLANK>


Default = NO

RFIOUT

This parameter controls the output of modal super


element for use in the RecurDyn multibody dynamics
software from FunctionBay.

<YES, NO>
Default = NO

RHOCP

The scale factor used to calculate ERP in decibels


(dB).

Real > 0.0


Default = 1.0

RSPLICOR

RSPLINE end rotation correction.

0, 1, REAL > 1.0


Default = 0

1526 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Description

Values

SEP1XOVR

The old and new location of moved shell grid points


are printed if SEP1XOVR = 16.

0, 16
Default = 0

SEPLOT

Output display model to .seplot file, from a CMS


run.

<YES, NO>
Default = YES

SH4NRP

Controls the full projection of 4-node shell elements


in NLGEOM implicit analysis.

0, 1, 2
Default = 0 in NLGEOM
subcases
Default = 1 in IMPDYN
subcases

SHELOS11

Allows you to revert to the first order shell element


<YES, NO>
formulation (for CQUAD4 and CTRIA3) used in version Default = NO
11.0.240 and earlier.

SHL2MEM

A shell property (defined by the PSHELL bulk data


entry) is automatically converted into a membrane
property if the membrane thickness (field T) of the
PSHELL bulk data entry is less than the value
specified using PARAM, SHL2MEM.

<Real Number > 0.0>


No default

SHPBCKOR

Defines the type and order of approximation used in


plate bending geometric stiffness for linear shell
elements (CQUAD4, CTRIA3).

1, 2
Default = 1

SIMPACK

Requests generation of the SIMPACK .fbi file


containing flexible body information for SIMPACK
analysis.

0, 1, 2, 3, 4, 5
Default =0

SMDISP

Controls if small displacement formulation or large


displacement formulation is used.

0, 1
Default = 0

SNAPTHRU

Controls the output of the force-deflection curve in


geometric nonlinear analysis.

<YES,NO>
Default = NO

SORTCON

Controls the output of violated constraints to the


.out file from an optimization.

<INTEGER>
Default = 20

SPLC

Specifies the speed of sound used in the wave


number and the complex particle velocity vector
calculations.

Real > 0.0


Default = 1.0

Altair Engineering

OptiStruct 13.0 Reference Guide 1527


Proprietary Information of Altair Engineering

Parameter

Description

Values

SPLFAC

Specifies the scale factor (q ) used to calculate the


Sound Pressure Level in Radiated Sound Analysis.

Real > 0.0


Default = 1.0

SPLREFDB

Specifies the reference sound pressure value used


to calculate the Sound Pressure Level (SPL) in
decibels (dB).

Real > 0.0


Default = 1.0

SPLRHO

Specifies the density of the acoustic medium in the


calculation of the complex acoustic sound pressure
and the complex particle velocity vector.

Real > 0.0


Default = 1.0

SRCOMPS

Outputs the strength ratios for composite elements


that have failure indices requested.

<YES, NO>
Default = NO

SS2GCR

Controls the accuracy of the external AMLS


eigenvalue solution.

<REAL>
Default = 5.0

STRTHR

Specifies the von Mises stress threshold value above


which the stress results are output for a model.
Default = 0.0

THCNTPEN

Controls the penalty factor used in thermal contact


analysis.

AUTO, LOW, HIGH


Default = AUTO

TOLRSC

Connecting grid points of the shell element are


moved onto the solid face.

<REAL>
Default = 0.05

TRAKMETH

Used to select the criterion employed for mode


tracking.

<0, 1, 2>
Default = 0

TRAKMTX

Controls output of the mode tracking matrix during


optimization.

<0, 1>
Default = 0

TPS

Activate fast transient response analysis (only shell


stress results output).

<YES, NO>
Default = YES

UCORD

Specifies the coordinate system in which the mass


moment of inertia is output. It also can be used to
control the point about which the mass moment of
inertia is calculated.

<CID>

Allows you to prevent the inclusion of the Virtual

<Integer = 0, 1, 2>

VMOPT

1528 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Default = -1

Altair Engineering

Parameter

Description

Values

Mass Matrix in the Regular Mass Matrix for Modal


Dynamic Subcases. In such cases, the virtual mass
is added after the eigen solution and modes are
modified based on the virtual mass matrix.

Default = 0

W3

Convert structural damping to equivalent viscous


damping for transient analysis.

<REAL>
Default = 0.0

W4

Convert structural damping to equivalent viscous


damping for transient analysis.

<REAL>
Default = 0.0

WR3

Used to include or exclude frequency dependent


damping in rotor dynamics analysis.

<REAL>
Default = 0.0

WR4

Used to include or exclude frequency dependent


damping in rotor dynamics analysis.

<REAL>
Default = 0.0

WTMASS

Convert weights to masses using this multiplier.

REAL > 0.0


Default = 1.0

Comments
1.

This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1529


Proprietary Information of Altair Engineering

PARAM, ACMODL12
Parameter
ACMODL

Values

Description

<YES, NO>
Default = NO

PARAM, ACMODL12, YES can be used to restore the


ACMODL formulation used in version 12.0 and earlier for the
Fluid-Structure Interface.
Note
In OptiStruct 13.0 the new and improved ACMODL
formulation will couple the fluid grids at the interface to only
a single layer of structural grids. This parameter can be
used to restore the formulation used prior to 13.0. The old
formulation coupled the fluid face to every structural grid in
the search box.

1530 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, AGGPCH
Parameter
AGGPCH

Values

Description

<YES, NO>
Default = NO

If YES, OptiStruct will output the Fluid-Structure


coupling matrix to the Punch file (.pch) as a matrix
defined using the DMIG data entry, with the name
AGGAX. This DMIG can be used in a subsequent
OptiStruct run using the A2GG Solution Control
Command.
If NO, the Fluid-Structure coupling matrix will not be
output to the Punch file (.pch).

Altair Engineering

OptiStruct 13.0 Reference Guide 1531


Proprietary Information of Altair Engineering

PARAM, AKUSMOD
Parameter
AKUSMOD

Values

Description

<YES, NO>
Default = NO

If YES, this indicates that OptiStruct should use a fluidstructure coupling matrix generated by AKUSMOD. In this
case, the ACMODL data is ignored.
By default it is presumed that the AKUSMOD coupling matrix
is to be found in the same directory as the solver input file
and is given the file name ftn.70. However an alternate
file name and location may be assigned via the
ASSIGN,AKUSMOD command.

1532 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ALPHA1
Parameter
ALPHA1

Values

Description

<REAL>
Default = 0.0

PARAM, ALPHA1 is used in frequency response,


transient response and modal complex eigenvalue
analyses.
If PARAM, ALPHA1 and/or PARAM, ALPHA2 are not equal
to zero, then Rayleigh damping is added to the viscous
damping. ALPHA1 is the scale factor applied to the
mass matrix and ALPHA2 to the structural stiffness
matrix as in:

Altair Engineering

OptiStruct 13.0 Reference Guide 1533


Proprietary Information of Altair Engineering

PARAM, ALPHA2
Parameter
ALPHA2

Values

Description

<REAL>
Default = 0.0

PARAM, ALPHA2 is used in frequency response, transient


response and modal complex eigenvalue analyses.
If PARAM, ALPHA1 and/or PARAM, ALPHA2 are not equal to
zero, then Rayleigh damping is added to the viscous
damping. ALPHA1 is the scale factor applied to the mass
matrix and ALPHA2 to the structural stiffness matrix as in:

1534 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ALPHA1FL
Parameter
ALPHA1FL

Values

Description

<REAL>
Default = 0.0

PARAM, ALPHA1FL is used in frequency and transient


response analysis.
If PARAM, ALPHA1FL and/or PARAM, ALPHA2FL are not equal
to zero, then Rayleigh damping is added to the viscous
damping. ALPHA1FL is the scale factor applied to the mass
matrix and ALPHA2FL to the fluid stiffness matrix as in:

Altair Engineering

OptiStruct 13.0 Reference Guide 1535


Proprietary Information of Altair Engineering

PARAM, ALPHA2FL
Parameter
ALPHA2FL

Values

Description

<REAL>
Default = 0.0

PARAM, ALPHA2FL is used in frequency and transient


response analysis.
If PARAM, ALPHA1FL and/or PARAM, ALPHA2FL are not equal
to zero, then Rayleigh damping is added to the viscous
damping. ALPHA1FL is the scale factor applied to the mass
matrix and ALPHA2FL to the fluid stiffness matrix as in:

1536 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, AMLS
Parameter

Values

Description

AMLS

YES, NO
Default = NO

This parameter is used to invoke the external AMLS


eigenvalue solver. This solver is faster than the Lanczos
solver for large eigenvalue problems. Note that AMLS must
be installed on the system and the environment variable
AMLS_EXE must point to the AMLS executable for this
setting to work.
If YES, then the external AMLS eigenvalue solver is used.
If NO, then the internal Lanczos eigenvlaue solver is used.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1537


Proprietary Information of Altair Engineering

PARAM, AMLSMAXR
Parameter

Values

Description

AMLSMAXR

<REAL>
PARAM, AMLSMAXR is used to determine singularities in
Default = 1.0e-8 the stiffness matrix.
If the value of AMLSMAXR is exceeded in the process of
factoring a stiffness matrix, this indicates a singularity in
K. If the mass of this degree-of-freedom is zero, there
is a "massless mechanism"; an SPC is applied and a
message is written to the .out file. If there is mass,
then this is a mechanism which is treated as a rigid body
mode and a message is written to the .out file.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

1538 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, AMLSMEM
Parameter

Values

AMLSMEM

<REAL>

Description

This parameter is used to define the amount of memory


in Gigabytes to be used by the external AMLS eigenvalue
Default =
solver. This parameter is only valid for AMLS versions 5
Memory used by and higher.
OptiStruct for a
Note
particular run.
1.

If this parameter is not set, AMLS will use the


amount of memory that OptiStruct is using for the
run.

2.

OptiStruct and AMLS can be run with different


allocations of memory. For example, OptiStruct can
be run with 10.0 Gigabytes and AMLS with 20.0
Gigabytes in the same run.

3.

If the environment variable AMLS_MEM is set, it will


override the value set using PARAM,AMLSMEM.

4.

This parameter can be used only if PARAM, AMLS is


set to YES.

Refer to the Users Guide section, Using the AMLS


(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1539


Proprietary Information of Altair Engineering

PARAM, AMLSNCPU
Parameter

Values

Description

AMLSNCPU

1, 2, 4
Default = no. of
cpus
used by the solver

This parameter is used to define the number of cpus


to be used by the external AMLS eigenvalue solver.
This parameter will set the environment variable
OMP_NUM_THREADS.
The default value is the current value of
OMP_NUM_THREADS. Note that this value can be set
through the command line arguments nproc or
ncpu.
OptiStruct and AMLS can be run with different
allocations of processors. For example, OptiStruct
can be run with 1 processor and AMLS with 4
processors in the same run.
Only valid when PARAM, AMLS is set to YES.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver
for more details.

1540 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, AMLSUCON
Parameter
AMLSUCON

Values

Description

0, 1
Default = 0

This parameter is used to indicate whether or not


unconnected grids are to be constrained for AMLS run.
If 0, then unconnected grids are not constrained.
If 1, then unconnected grids are to be constrained.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1541


Proprietary Information of Altair Engineering

PARAM, AMSESLM
Parameter
AMSESLM

Values

Description

<YES, NO>
Default = NO

YES: The EIGRA (AMSES) numerical method for enforced


motion based modal dynamic analysis with large mass
method will be activated.
NO: The EIGRA (AMSES) numerical method for enforced
motion based modal dynamic analysis with large mass
method will not be activated.

1542 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ASCOUP
Parameter
ASCOUP

Values

Description

<YES, NO>
Default = YES

If YES, the fluid-structure coupling (area) matrix will


be calculated and used in the solution.
If NO, the fluid-structure (area) matrix is not
calculated.
Note: PARAM,AGGPCH,YES should be used to output
the matrix to the Punch (.pch) file.
PARAM,ASCOUP,NO is required when the fluidstructure coupling (area) matrix is read in from
the Punch (.pch) file.

Altair Engineering

OptiStruct 13.0 Reference Guide 1543


Proprietary Information of Altair Engineering

PARAM, AUTOMSET
Parameter
AUTOMSET

Values

Description

<YES, NO>
Default = YES
Defaults
1. The default is NO
when the
parameter is not
present in the
deck.
2. The default is YES
when PARAM,
AUTOMSET is
input without
specifying a
value.

If YES, the dependent degrees-of-freedom of rigid


elements may be converted to independent degreesof-freedom when conversion is necessary for the
model to run.
If NO, the above conversion will not be performed.
The model may not run when multiple constraint
equations reference the same dependent degree-offreedom more than once.
Note:
1.

This parameter can be used if the dependent


degree-of-freedom (DOF) of a rigid element is
SPCed, part of the ASET, or if it is a dependent
DOF of another constraint equation (MPC
equation or another rigid element).

2.

PARAM, AUTOMSET, YES can be used in models


with SPCed dependent rigid element grids, only
if multiple SPC sets are present in multiple
subcases.

3.

AUTOMSET cannot be used to convert the


dependent degrees of freedom (DOFs) of a rigid
element constrained by global SPCs to
independent DOFs. In such situations, it is
recommended to create another subcase with a
different SPC set.

4.

AUTOMSET cannot be used if Direct Matrix Input


(DMIG) generation is performed using the Static
Condensation method (Component Mode
Synthesis (CMSMETH entry) is not used).

1544 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, AUTOSPC
Parameter

Values

Description

AUTOSPC

YES, NO
Default = YES

If YES, the global stiffness matrix is checked for


degrees-of-freedom with no stiffness. If found, these
degrees-of-freedom are automatically constrained.
If NO, the degrees of freedom with no stiffness are not
automatically constrained.

Altair Engineering

OptiStruct 13.0 Reference Guide 1545


Proprietary Information of Altair Engineering

PARAM, AUTOSPRT
Parameter

Values

Description

AUTOSPRT

<1, 0>
Default = 1

This parameter applies to residual vector calculation in


inertia relief analysis.
If 1, rigid body modes from the eigenvalue analysis
(PARAM,FZERO defines cut-off for determination of rigid
body modes) are used to automatically generate
SUPORT dofs.
If 0, SUPORT dofs are automatically generated using the
6 geometric rigid body modes.

1546 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, BUSHRLMT
Parameter
BUSHRLMT

Values

Description

<Real Number > This parameter is used to issue a WARNING when the
0.0>
stiffness value for rotational components on the PBUSH
entry exceeds the specified limit (BUSHRLMT).
Default = 1.0E +
09
Note: This check is overridden when PARAM, BUSHSTIF
is used to control the maximum stiffness value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1547


Proprietary Information of Altair Engineering

PARAM, BUSHSTIF
Description
This parameter can accept two arguments. If only one argument is specified, the same value
is used for the second argument.
Format
PARAM, BUSHSTIF, <BUSHSTIFT>, <BUSHSTIFR>
Parameter
BUSHSTIFT

Values

Description

<Real Number > This parameter controls the value of field K in the
0.0>
PBUSH property entries.
No default

BUSHSTIFR

BUSHSTIFT:
This value applies to translational stiffness fields on the
property entry (first three values).

<Real Number >


BUSHSTIFR:
0.0>
This value applies to rotational stiffness values on the
Default =
property entry.
<BUSHSTIFT>
Note:
1.

Any value on the field K on the PBUSH entry which


exceeds BUSHSTIFT or BUSHSTIFR, respectively will
be replaced by BUSHSTIFT or BUSHSTIFR.

2.

Either BUSHSTIFT or BUSHSTIFR (or both) can be


set to 0.0. This will disable stiffness control for the
corresponding translational or rotational stiffnesses.

3.

Defaults:
a. If BUSHSTIFT is input without specifying a value,
then OptiStruct will error out (no default). The
default for BUSHSTIFR is BUSHSTIFT.
b. If PARAM, BUSHSTIF is not included in the deck,
the stiffness value (Field K) is not replaced
regardless of its value (no stiffness control).

4.

This parameter applies, in a similar fashion, to the


PBUSH1D Rod-type Spring-and-Damper Property as
well (using BUSHSTIFT).

1548 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, BUSHTLMT
Parameter
BUSHTLMT

Values

Description

<Real Number > This parameter is used to issue a WARNING when the
0.0>
stiffness value for translational components on the
PBUSH entry exceeds the specified limit (BUSHTLMT).
Default = 1E+07
Note: This check is overridden when PARAM, BUSHSTIF
is used to control the maximum stiffness value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1549


Proprietary Information of Altair Engineering

PARAM, CB2
Parameter

Values

Description

CB2

Real
Default = 1.0

CB2 specified factors for the direct input damping matrix.


The total damping matrix is:

where

is selected via the subcase information

command B2GG, and


comes from CDAMP1, CDAMP2,
CDAMP3, CDAMP4, or CVISC element bulk data entries.

1550 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CHECKEL
Parameter
CHECKEL

Values

Description

NO, YES, FULL


Default = YES

If NO, element quality checks are not performed, but


mathematical validity checks are performed.
If YES, the geometric quality of each element is
checked. Any violation of the error limits is counted as a
fatal error and the run will stop. Any violation of warning
limits is non-fatal. Error or warning messages are printed
for elements violating the limits along with the offending
property values. The amount of output is limited to the
first 3 occurrences for each individual case, plus a
summary table of all errors.
If FULL, the same checks are performed as for YES, but
the error or warning messages are printed for all of the
elements violating the error or warning limits.
See Element Quality Check for an overview of the
element quality checking performed by the solver.
The ELEMQUAL bulk data entry may be used to control
the values for warning and error limits for each quality
check, but validity limits cannot be altered by the user.

Altair Engineering

OptiStruct 13.0 Reference Guide 1551


Proprietary Information of Altair Engineering

PARAM, CHECKMAT
Parameter
CHECKMAT

Values

Description

YES, NO, FULL


Default = YES

If YES, the material properties for all referenced material


definitions are checked for adherence to the default
material requirements as described on the Material
Property Check page. The amount of output is limited.
If NO, mathematical requirement checks only are
performed for all referenced material definitions.
If FULL, material property checks are performed as when
the value is YES, but all violations are output.

1552 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CHKGPDIR
Parameter
CHKGPDIR

Values

Description

YES, NO, WARN,


FULL, REVERSE
Default = YES

If YES, all gap elements of non-zero length (distance


between GA-GB) that have a prescribed coordinate
system CID are checked for misalignment of gap
prescribed axis (x-axis of CID) with the vector GA->GB
(angles larger than 30 degrees produce errors). The
amount of output is limited to the first ten occurrences.
Note that this check applies correctly to the most
typical situations where in there is an initial opening
between bodies A and B, and the gap element is used
to enforce non-penetration condition (for other cases,
see the REVERSE option below).
If NO, no gap CID direction checks are performed.
If WARN, only warnings are issued.
If FULL, the error or warning messages are printed for
all gap elements violating this check.
If REVERSE, orientations of vector GA->GB generally
opposite to the prescribed x-axis of CID system are also
accepted (this can be used in cases when gap is used
to model rope behavior or when there is initial
penetration, rather than gap, between bodies A and B).
The tolerance levels are the same as for YES, except
that they are measured from either 0 or 180 degrees
reference angle.
For more details, refer to the CGAP description.
PARAM, CHKGPDIR is superseded by the CKGAPDIR
parameter on the GAPPRM bulk data entry if present.

Altair Engineering

OptiStruct 13.0 Reference Guide 1553


Proprietary Information of Altair Engineering

PARAM, CK2
Parameter
CK2

Values

Description

Real
Default = 1.0

CK2 specifies factors for the direct input stiffness matrix.


The total stiffness matrix is:

where

is selected via the subcase information

command K2GG, and


is generated from structural
element entries in the bulk data section.

1554 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CK3
Parameter
CK3

Values

Description

Real
Default = 1.0

CK3 specifies factors for the stiffness matrix produced by


GENEL cards. The total stiffness matrix is:

where

is the stiffness generated by all GENEL cards

and
is the combination of the stiffness generated
from structural element entries in the bulk data section and
the stiffness generated by the subcase information
command K2GG and scaled by PARAM,CK2.

Altair Engineering

OptiStruct 13.0 Reference Guide 1555


Proprietary Information of Altair Engineering

PARAM, CM2
Parameter
CM2

Values

Description

Real
Default = 1.0

CM2 specifies factors for the direct input mass matrix. The
total mass matrix is:

where

is selected via the subcase information

command M2GG, and


is generated from the mass
element entries in the bulk data section.

1556 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CMFTINIT
Parameter
CMFTINIT

Values

Description

0.0 < REAL < 1.0 PARAM, CMFTINIT defines the lower threshold value used
Default = 0.0
for the HyperMesh command files *.HM.comp.cmf and
*.HM.ent.cmf.
These command files are used to organize elements,
which formed a topology or free-size design space, into
components (.comp.cmf) or sets (.ent.cmf), based on
their optimized densities/thicknesses.

Altair Engineering

OptiStruct 13.0 Reference Guide 1557


Proprietary Information of Altair Engineering

PARAM, CMFTSTEP
Parameter
CMFTSTEP

Values

Description

0.0 < REAL < 1.0


Default = 0.1

PARAM, CMFTSTEP defines the step or interval value


used for the HyperMesh command files *.HM.comp.cmf
and *.HM.ent.cmf.
These command files are used to organize elements,
which formed a topology or free-size design space, into
components (.comp.cmf) or sets (.ent.cmf), based on
their optimized densities/thicknesses.

1558 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CMSALOD
Parameter
CMSALOD

Values

Description

<YES, NO>
Default = YES

PARAM, CMSALOD controls the generation of RFORCE and


Gravity loads from the mass matrix stored in the PUNCH
DMIG or H3DDMIG file.
If YES, the RFORCE and Gravity loads include the
contribution from the mass matrix stored in the PUNCH
DMIG or H3DDMIG file.
If NO, the DMIG mass contribution is ignored when
generating the RFORCE and Gravity loads.
Refer to Direct Matrix Input and DMIG.

Altair Engineering

OptiStruct 13.0 Reference Guide 1559


Proprietary Information of Altair Engineering

PARAM, CMSDIRM
Parameter
CMSDIRM

Values

Description

YES, NO
Default = NO

PARAM, CMSDIRM allows flexible body generation when


directional masses are defined in the input file.
If YES, the existence of directional mass will be allowed
for flexbody generation runs. A warning will be issued for
the ignored or approximated CMASS1, CMASS2, and
CONM1.
If NO, the run will be terminated with an ERROR if the
input file contains directional mass definitions and flexible
body generation is requested.
See the Users Guide entry on Flexible Body Generation.

1560 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CMSOFST
Parameter
CMSOFST

Values

Description

<YES, NO>
Default = NO

PARAM, CMSOFST applies to Component Mode Synthesis


(CMS) runs for flexbody generation.
While element offsets are valid for DMIG generation, that
is performing CMS with METHOD = CBN or GUYAN, they
are undesirable for flexbody generation, that is
performing CMS with METHOD = CC or CB, as it may
introduce approximation error into the generated
flexh3d file, and so in general, you will not solve these
problems.
However, the approximation error for plates offset by
half of their thickness, such that the grids can be
aligned on one side of the plate surface, is tolerable.
Setting this parameter to YES will allow problems with
this kind of offset to be solved.

Altair Engineering

OptiStruct 13.0 Reference Guide 1561


Proprietary Information of Altair Engineering

PARAM, COEFFC
Parameter

Values

Description

COEFFC

Real > 0.0

Value of the friction coefficient on curvatures for onestep stamping simulation.

1562 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, COMP2SHL
Parameter

Values

Description

COMP2SHL

YES, NO,
BULK
Default = NO

If YES or blank, results of homogenization of composite


properties (equivalent shell and material, PSHELL and
MAT2) will be printed in a descriptive form in the
.out file.
If NO, echo of composite homogenization will not be
printed.
If BULK, then results of composite homogenization
(equivalent PSHELL and MAT2) will be printed in a
version corresponding to bulk data input in large field
(long) format. This version can be cut and pasted
directly into an OptiStruct input deck.
Note: The equivalent shell and materials represent
composite properties as they are defined in the
input deck. In optimization runs involving
composites, OptiStruct internally adjusts and
changes the composite properties. Such
changes are not reflected in the equivalent
shell results printed by this command.

Altair Engineering

OptiStruct 13.0 Reference Guide 1563


Proprietary Information of Altair Engineering

PARAM, CONTFEL
Parameter

Values

Description

CONTFEL

<YES, NO>
Default = NO

If YES, Contact-friendly elements are activated.


PARAM, CONTFEL, YES is recommended when second
order solids/gaskets are used with contact analysis in
OptiStruct.
If NO, Contact-friendly elements are not activated.

1564 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, COUPMASS
Parameter

Values

Description

COUPMASS

-1, 0, 1, YES,
NO
Default = NO

If -1, 0 or NO, the lumped mass matrix approach is used


for eigenvalue analysis.
If 1 or YES, the coupled mass matrix approach is used
for eigenvalue analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide 1565


Proprietary Information of Altair Engineering

PARAM, CP2
Parameter

Values

Description

CP2

Real
Default = 1.0

CP2 specifies factors for the direct input load matrix.


The total load matrix is:

where

is selected via the subcase information

command P2G, and


is generated from the static
load entries in the bulk data section.

1566 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, CSTEVAL
Parameter

Values

Description

CSTEVAL

YES, NO
Default = YES

This parameter controls whether to use wall time based


cost evaluation to provide the optimal performance in
running Lanczos steps.
The wall time based cost evaluation is a function of
system performance, hence it could be influenced by the
system load. Although it rarely happens, this influence
could result in a different number of Lanczos steps,
which could cause the resulting eigenvalues having a
round off difference. In most cases, this small difference
in solution is completely negligible for analysis. However,
it can produce visible differences in optimization runs or
in any solution that is sensitive to the small difference of
the obtained eigenvalues and eigenvectors.
If Yes, the wall time based cost evaluation is performed.
If NO, the wall time based cost evaluation is not
performed.

Altair Engineering

OptiStruct 13.0 Reference Guide 1567


Proprietary Information of Altair Engineering

PARAM, CSTOL
Parameter

Values

Description

CSTOL

<Real>
Default = 3.5

PARAM, CSTOL relates to the FastFRS interface.


If the low rank representation is not selected, then a
cancellation tolerance must be provided. The CSTOL
value specifies how many decimal digits may be lost to
cancellation in one operation during the eigensolution
process. Since double precision arithmetic maintains
nearly 16 digits of precision, the recommended limit of
3.5 on the number of digits lost leaves more than 12
digits, which is quite conservative for maintaining
adequate accuracy for engineering purposes. You may
choose to increase this value to speed computation, at
the risk of introducing inaccuracy from uncorrected
cancellation error. Setting it to 16 turns off the
capability to address cancellation error in the
eigensolution, and this has consistently been found to
give very satisfactory results when the number of modes
is under three thousand.
Refer to the Users Guide section, FastFRS Usage (Fast
Frequency Response Solver) for more details.

1568 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, DFREQ
Parameter

Values

Description

DFREQ

Real
Default = 10-5

DFREQ specified the threshold for the elimination of


duplicate frequencies on all FREQi bulk data entries.
and

are considered duplicated if

where
and
are the maximum and minimum
excitation frequencies of the combined FREQi entries.

Altair Engineering

OptiStruct 13.0 Reference Guide 1569


Proprietary Information of Altair Engineering

PARAM, DISIFMCK
Parameter

Values

Description

DISIFMCK

<YES, NO>
Default = NO

For vibrational eigenvalue analysis, the mass matrix must be


positive semi-definite. However, if this is simply caused by
numerical ill-conditioning, then PARAM,DISIFMCK may be used
to skip the indefinite mass matrix check.
YES

Skip indefinite mass matrix checking.

NO

Perform indefinite mass matrix checking.

1570 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, DISJOINT
Parameter

Values

Description

DISJOINT

<Integer>
DISJOINT is used to allow AMLS to handle disconnected
Default = NONE parts. This can also be accomplished with
PARAM,AMLSUCON.
PARAM, DISJOINT should be set to one larger than the
number of disconnected parts as determined by AMLS.
PARAM, DISJOINT causes the environment variable
AMLS_NPART to be set to the value of PARAM, DISJOINT.
AMLS will read the value of AMLS_NPART and handle the
disconnected structure.
PARAM, DISJOINT can be set to a real value for
compatibility, but it is recommended to use an integer
value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1571


Proprietary Information of Altair Engineering

PARAM, DUPTOL
Parameter

Values

Description

DUPTOL

<0, 1, 2, 3, 4, 5> PARAM, DUPTOL controls how many decimal places


Default = 0
can differ when comparing X, Y, and Z coordinates on
GRID and CORDxx cards with identical ID. Obsolete,
use SYSSETTINGS,DUPTOL command.

1572 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, EFFMAS
Param
eter

Values

Description

EFFMA
S

<YES,
NO,
Integer>
Default =
NO

When EFFMAS < 0 or NO, the modal participation factors, modal


participation factor ratio, and modal effective mass are not output for
normal modes analysis.
When EFFMAS > 0 or YES, the modal participation factors, modal
participation factor ratio, and modal effective mass will be computed and
output to the .out and .pch files for normal modes analysis. They are
computed as follows:

Modal Participation Factor =


The Modal Participation Factor is a measure of how close each mode is
to a rigid body mode.
The Modal Participation Factor Ratio is the Modal Participation Factor for
each rotational and translational direction divided by the maximum Modal
Participation Factor of all the modes for that direction. So, each of the
six directions will have a value of 1.0 for the mode that has the
maximum Modal Participation Factor and the other modes will have a
value less than 1.0.

Modal Effective Mass =


The Modal Effective Mass is a measure of how much mass is associated
with each mode.
whe
re

Altair Engineering

is the matrix of eigenvectors.


[m]

is the system mass matrix.

[V]

is the objective function matrix. Six rigid body modes are


used as objective function in normal modes analysis to
obtain [PF] and [EFFMAS].

[M]

is the diagonal modal mass matrix.

OptiStruct 13.0 Reference Guide 1573


Proprietary Information of Altair Engineering

PARAM, EHD
Parameter

Values

Description

EHD

<YES, NO>
Default = NO

This parameter is used to print the inverse of the


stiffness matrix created by static reduction to FORTRAN
unit 3. The inverse reduced stiffness matrix is written in
NASTRAN MATPRN format.
To perform static reduction there must be ASET data
and PARAM,EXTOUT,DMIGPCH in the input data. After
the stiffness matrix is reduced to the ASET DOF, its
inverse is calculated and written using NASTRAN
MATPRN format to FORTRAN unit 3.
PARAM,EXTOUT,DMIGPCH must also be specified when
this parameter is used in order to trigger the static
reduction.

1574 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ELASRLMT
Parameter
ELASRLMT

Values

Description

<Real Number >


0.0>
Default = 1.0E +
09

This parameter is used to issue a WARNING when the


stiffness value for rotational components on the
CELAS2/4 or PELAS entry exceeds the specified limit
(ELASRLMT).
Note: This check is overridden when PARAM, ELASSTIF
is used to control the maximum stiffness value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1575


Proprietary Information of Altair Engineering

PARAM, ELASSTIF
Description
This parameter can accept two arguments. If only one argument is specified, the same value
is used for the second argument.
Format
PARAM, ELASSTIF, <ELASSTIFT>, <ELASSTIFR>
Parameter
ELASSTIFT

ELASSTIFR

Values

Description

<Real Number > This parameter controls the value of field K in the
0.0>
PELAS scalar elastic property entry and the CELAS2/
CELAS4 scalar spring property and connection entries.
No default
ELASSTIFT:
This value applies to translational stiffness fields on the
PELAS scalar elastic property entry and the CELAS2/
CELAS4 scalar spring property and connection entries.
ELASSTIFR:
This value applies to rotational stiffness values on the
<Real Number > PELAS scalar elastic property entry and the CELAS2/
0.0>
CELAS4 scalar spring property and connection entries.
Default =
<ELASSTIFT>

Note:
1.

Any value on the field K on the PELAS or CELAS2/


CELAS4 entry which exceeds ELASSTIFT or
ELASSTIFR, respectively will be replaced by
ELASSTIFT or ELASSTIFR.

2.

Either ELASSTIFT or ELASSTIFR (or both) can be set


to 0.0. This will disable stiffness control for the
corresponding translational or rotational stiffnesses.

3.

Defaults:
a. If ELASSTIFT is input without specifying a value,
then OptiStruct will error out (no default). The
default for ELASSTIFR is ELASSTIFT.
b. If PARAM, BUSHSTIF is not included in the deck,
the elastic property value (Field K) is not replaced
regardless of its value (no stiffness control).

1576 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ELASTLMT
Parameter
ELASTLMT

Values

Description

<Real Number >


0.0>
Default = 1E+07

This parameter is used to issue a WARNING when the


stiffness value for translational components on the
CELAS2/4 or PELAS entry exceeds the specified limit
(ELASTLMT).
Note: This check is overridden when PARAM, ELASSTIF
is used to control the maximum stiffness value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1577


Proprietary Information of Altair Engineering

PARAM, ENFMOTN
Parameter

Values

Description

ENFMOTN

<REL, ABS,
TOTAL>
Default = ABS

If ABS, TOTAL or blank, the displacements/velocities/


accelerations output during Modal Frequency Response
Analysis and Modal Transient Response Analysis are the
total/absolute displacements/velocities/accelerations
that include the specified enforced motion. Stresses/
forces will be calculated (if requested) based on the
total displacements/velocities/accelerations.
If REL, the displacements/velocities/accelerations output
during Modal Frequency Response Analysis and Modal
Transient Response Analysis are relative to the enforced
motion specified in the model. Stresses/forces will be
calculated (if requested) based on the relative
displacements/velocities/accelerations.

1578 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ERPC
Parameter

Values

Description

ERPC

Real > 0.0


Default = 1.0

The speed of sound used in the ERP calculation:

Altair Engineering

OptiStruct 13.0 Reference Guide 1579


Proprietary Information of Altair Engineering

PARAM, ERPREFDB
Parameter

Values

Description

ERPREFDB

Real > 0.0


Default = 1.0

This parameter can be used to specify the reference


power value used to calculate Equivalent Radiated Power
(ERP) in decibels (dB).
Note:
The Equivalent Radiated Power (ERP) in decibels can be
calculated using the following equation:

Where,
ERPdB is the Equivalent Radiated Power in decibels.
RHOCP is the value of the scale factor specified using
the parameter PARAM, RHOCP.
ERPREFDB is the reference power value specified using
this parameter.

1580 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, ERPRHO
Parameter

Values

Description

ERPRHO

Real > 0.0


Default = 1.0

The fluid density used in ERP calculations:

Altair Engineering

OptiStruct 13.0 Reference Guide 1581


Proprietary Information of Altair Engineering

PARAM, ERPRLF
Parameter

Values

Description

ERPRLF

Real > 0.0


Default = 1.0

The Radiation Loss Factor used in the ERP calculation:

1582 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, EXCEXB
Parameter
EXCEXB

Values

Description

<YES, BOTH, NO> This parameter controls the output of the AVL/EXCITE
.exb file directly from OptiStruct.
Defaults
If this parameter If YES, the AVL/EXCITE .exb file is output.
is included in the
If BOTH, the AVL/EXCITE .exb file and the old files
input file, but, no
(.doft, .geom, _mff.out4, _x2oa.out4, and .out4)
value is provided,
are output.
then the default
value is YES.
If NO, the AVL EXCITE interface output files are not
If this parameter output.
is not included in Note: PARAM, EXCEXB, YES/BOTH should be used in
the input file (and
conjunction with PARAM, EXCOUT. OptiStruct will
PARAM, EXCOUT
error out if PARAM, EXCEXB, YES/BOTH is
is present), then
specified without PARAM, EXCOUT in the model.
the default value
is BOTH.

Altair Engineering

OptiStruct 13.0 Reference Guide 1583


Proprietary Information of Altair Engineering

PARAM, EXCOUT
Parameter

Values

Description

EXCOUT

<-1, 0, 1, 3, 4, 5,
6>
Default = 0

Output of condensed superelement information for AVL/


EXCITE.
-1

No output.

All output.

DOF, geometry, and elements tables (GEOM1,


GEOM2, EQEXIN, and USET), as well as the
reduced mass and stiffness matrices (MAA and
KMAA).

1 + eigenvectors of the full system (GOA


transpose).

3 + unreduced mass matrix (MFF).

1 + eigenvectors of condensed system (PHA) and


the grid point stress table (OGS1).

4 + eigenvectors of condensed system (PHA) and


the grid point stress table (OGS1).

1.

When PARAM,EXCOUT,1 is defined, only the ASET


dofs are output when the MODEL card is not
present. Otherwise, the entire model is output when
the MODEL card is not present.

2.

PARAM, EXCEXB, BOTH is automatically activated if


PARAM, EXCOUT is present in the input deck.

1584 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, EXPERTNL
Parameter

Values

Description

EXPERTNL

YES, NO,
CNTSTB,
AUTO

YES activates a nonlinear "expert system" that aids in the


convergence of small displacement nonlinear problems
(NLSTAT). This version is designed to facilitate obtaining
converged, high accuracy solutions without much concern
for computational time. The system monitors the
convergence of nonlinear processes and, if needed,
implements measures designed to improve convergence for
poorly converging cases. These measures include:
performing additional iterations, under-relaxation, automatic
adjustment of the load increment, as well as backing off to
the last convergent solution and retrying. This may lead to
a large number of nonlinear iterations for poorly converging
problems.

Default =
AUTO

CNTSTB additionally introduces temporary stabilization on


contact interfaces (CONTACT or GAP(G) elements) that may
improve nonlinear convergence, especially in cases where
individual parts lack full support and are supported only by
contact. The stabilization is applied only during incremental
loading and is not present in the final solution for the
respective nonlinear subcase.
AUTO activates a light version of the expert system, which
is designed to facilitate converging nonlinear process in
reasonably close to minimum number of iterations. In
particular, this version may adjust the time step, including
increasing the time step beyond that prescribed on the
NLPARM card.
This parameter does not apply to geometric nonlinear
solution sequences (NLGEOM, IMPDYN or EXPDYN).

Altair Engineering

OptiStruct 13.0 Reference Guide 1585


Proprietary Information of Altair Engineering

PARAM, EXTOUT
Parameter

Values

Description

EXTOUT

DMIGPCH,
DMIGBIN
No default

EXTOUT controls the output of reduced matrices to


external data files for use in subsequent analyses.
If DMIGPCH, the matrices are written to an ASCII .pch
file.
If DMIGBIN, the matrices are written to a binary .dmg
file.
See the User's Guide section The Direct Matrix Approach
for more detailed information.

1586 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, FASTFR
Parameter

Values

Description

FASTFR

<YES, NO>
If, AUTO (Default), the faster method is automatically
Default = AUTO chosen by the program for Modal Frequency Response
Analysis. If the FASTFR method is not activated, the
standard method is used (see comments).
If YES, and if FASTFR is allowed (see comments), it
activates an alternative method to run Modal Frequency
Response Analysis that enhances the performance.
If NO, the FASTFR method is deselected and the program
is run using the standard solution method.
Comments:
The FASTFR method will be ignored for Modal Frequency
Response Analysis, if:
1.

Multiple modal spaces exist in the model.

2.

Single Program, Multiple Data (SPMD) parallelization


has been requested.

3.

Viscous degrees of freedom are significantly large.

The FASTFR method will be allowed, if Shared Memory


Parallelism (SMP) parallelization has been requested by
specifying the number of processors using the nproc run
option.

Altair Engineering

OptiStruct 13.0 Reference Guide 1587


Proprietary Information of Altair Engineering

PARAM, FFRS
Parameter

Values

Description

FFRS

<YES, NO>
Default = NO

This parameter is used to invoke the external FastFRS


(Fast Frequency Response Solver). This solver is very
efficient for a certain class of large modal frequency
response problems, such as those common in automotive
NVH analysis. Note that FastFRS must be installed on the
system and the environment variable FASTFRS_EXE must
point to the FastFRS executable for this setting to work.
If YES, then the external FastFRS solver is used.
If NO, then the internal solver is used.
Refer to the Users Guide section, FastFRS Usage (Fast
Frequency Response Solver) for more details.

1588 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, FFRSLFREQ
Parameter

Values

Description

FFRSLFREQ

<Real>
Default = 1.0

PARAM, FFRSLFREQ relates to the FastFRS interface.


It defines a frequency cut-off value in Hertz used to
partition the structural system into low frequency and
high frequency parts, to improve matrix condition
numbers and solution accuracy at a very small
computational cost.
If the value is defined as 0.0, then FastFRS will set
FFRSLFREQ to 1.0.
Refer to the Users Guide section, FastFRS Usage (Fast
Frequency Response Solver) for more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1589


Proprietary Information of Altair Engineering

PARAM, FFRSMEM
Parameter

Values

Description

FFRSMEM

<Real>

This parameter is used to define the amount of memory in


Gigabytes to be used by the external FastFRS modal
equation solver. This parameter is only valid for FastFRS
versions 2 and higher.

Default =
Memory used
by OptiStruct
for a particular
run.

Note:
1.

If this parameter is not set, FastFRS will use the


amount of memory that OptiStruct is using for the
run.

2.

If the environment variable FFRS_MEM is set, it will


override the value set using PARAM, FFRSMEM.

3.

OptiStruct and FastFRS can be run with different


allocations of memory. For example, OptiStruct can
be run with 10.0 Gigabytes and FastFRS with 20.0
Gigabytes in the same run.

4.

This parameter is only valid when PARAM, FFRS is set


to YES.

Refer to the Users Guide section, FastFRS Usage (Fast


Frequency Response Solver) for more details.

1590 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, FFRSNCPU
Parameter
FFRSNCPU

Values

Description

<Integer>
Default =
number of cpu's
used by
OptiStruct.

PARAM, FFRSNCPU relates to the FastFRS interface.


This parameter is used to define the number of cpus to
be used by the external FastFRS solver. This parameter
will set the environment variable OMP_NUM_THREADS.
The default value is the current value of
OMP_NUM_THREADS.
Note
1.

If FFRSNCPU is not set, but AMLSNCPU is set, the


FastFRS will use the number of cpus specified by
AMLSNCPU.

2.

OptiStruct and FastFRS can be run with different


allocations of processors. For example, OptiStruct
can be run with one processor and FastFRS with four
processors in the same run.

3.

This parameter is only valid when PARAM, FFRS or


the run option ffrs is set to YES.

Refer to the Users Guide section, FastFRS Usage (Fast


Frequency Response Solver) for more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1591


Proprietary Information of Altair Engineering

PARAM, FLEXH3D
Parameter

Values

Description

FLEXH3D

AUTO, YES, NO
Default = AUTO

This parameter controls the generation of flexh3d files


for flexible bodies in an MBD analysis.
If AUTO, flexh3d files are generated only for those
flexible bodies for which no previously generated
flexh3d file exists. Previously generated flexh3d files
are checked for validity; if the file is valid for the
corresponding flex-body definition, the run will
continue using the existing flexh3d file. If the file is
found to be invalid (has a different mass or the wrong
number of grids), an error termination will occur.
If YES, flexh3d files are generated for all flexible
bodies, overwriting existing files (if present).
If NO, flexh3d files are not generated. The run makes
use of previously generated files. An error termination
will occur if no such files exist.

1592 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, FLIPOK
Parameter

Values

Description

FLIPOK

NO, YES
Default = NO

If YES, severely distorted and possibly inverted elements


will be accepted by the solver. This is limited to first
order tetra (CTETRA) and tria (CTRIA3) elements.
If NO, severely distorted elements will not be accepted
by the solver, and the solution will be terminated with an
error to avoid inaccurate results.

Altair Engineering

OptiStruct 13.0 Reference Guide 1593


Proprietary Information of Altair Engineering

PARAM, FRIC
Parameter

Values

Description

FRIC

<REAL>
Default = 1.0

PARAM, FRIC defines a multiplier for matrices (DMIG)


referenced by K2PP.

1594 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, FZERO
Parameter

Values

Description

FZERO

<Real>
Default = 0.1

This parameter defines the maximum frequency for a rigid


body mode for the Lanczos eigensolver. That is all
eigenmodes with frequency at or below this cutoff will be
regarded as rigid body modes in the inertia relief
analysis.
Note:
To set the rigid body mode cutoff eigenvalue for the
AMSES and AMLS eigensolvers, use PARAM, RBMEIG.

Altair Engineering

OptiStruct 13.0 Reference Guide 1595


Proprietary Information of Altair Engineering

PARAM, G
Parameter

Values

Description

<Real>
Default = 0.0

G specifies the uniform structural damping coefficient in


the formulation of dynamics problems.
To obtain the value for the parameter G, multiply the
critical damping ratio, C/C0 by 2.0.
Note:
To achieve identical displacements in Modal frequency
response or Modal transient analyses when the SDAMPING
bulk data entry is used instead of PARAM, G, the steps
described here can be followed:
1.

The TYPE field in the TABDMP1 bulk data entry should


be set to CRIT. This TABDMP1 bulk data entry is
referenced by the SDAMPING subcase information
entry.

2.

Set the damping value (field gi) in the TABDMP1 bulk


data entry equal to half of the value of PARAM, G
(that is set the constant value to C/C0).

3.

Set PARAM, KDAMP,-1.

1596 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, GE_MOD
Parameter

Values

Description

GE_MOD

<Real or
NO_GE>
No default

The real value of GE_MOD overrides the value of GE


specified in all MATx material data, sets the table ID for
GE on the MATTx material data to zero, and overrides the
value of GE specified on the PCOMP, PCOMPP, and
PCOMPG data. GE_MOD can be set to 0.0 to remove all
material-based structural damping from the model. The
damping from PARAM, G will also be applied when GE_MOD
is present.
The GE_MOD setting of NO_GE is used to remove all
structural damping from the model. When NO_GE is
specified, the value of GE will be set to zero on all MATx
material data and the GE values specified in the CELAS2,
PELAS, PELAST, PBUSH, PBUSHT, PCOMP, PCOMPP, and
PCOMPG data will also be set to zero. In addition, the
table ID for GE on MATTx material data will be set to
zero. PARAM, G can be used to set the value to a
constant value for the entire structure.

Altair Engineering

OptiStruct 13.0 Reference Guide 1597


Proprietary Information of Altair Engineering

PARAM, GFL
Parameter

Values

Description

GFL

<Real>
Default = 0.0

GFL specifies the uniform fluid damping coefficient in the


formulation of dynamics problems. To obtain the value
for the parameter GFL, multiply the critical damping
ration, C/C0, by 2.0.
In coupled fluid-structure models, PARAM, G is applied to
structural portion and PARAM, GFL to the fluid portion.

1598 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, GMAR
Parameter

Values

Description

GMAR

<REAL>
Default = 1.1

PARAM, GMAR is used to control the accuracy of the


AMLS solution.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1599


Proprietary Information of Altair Engineering

PARAM, GMAR1
Parameter

Values

Description

GMAR1

<REAL>
Default = 1.7

PARAM, GMAR1 is used to control the accuracy of the


AMLS solution.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

1600 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, GPSLOC
Parameter
GPSLOC

Values

Description

Z1, Z2 and MID Used to control the where grid point stresses are
calculated for output to the .mnf file.
Default = Z1
The highest stresses are at the bottom (Z1) or top (Z2)
surface of the shell. For pure bending, they have the
same magnitude.
GPSLOC is used to specify the location of the calculation
of the grid point stresses. They can be calculated at the
bottom surface (Z1), top surface (Z2), or at the midplane (MID).

Altair Engineering

OptiStruct 13.0 Reference Guide 1601


Proprietary Information of Altair Engineering

PARAM, GRDPNT
Parameter
GRDPNT

Values

Description

<GID>

If = -1, no output from grid point weight generator.

Default = -1

If = 0, the center of gravity coordinates are relative to


the origin of the basic coordinate system and are
expressed in the coordinate system CID.
If > 0, the center of gravity coordinates are relative to
GID and are expressed in the coordinate system CID.
Note:
1.

The coordinate system CID is defined by PARAM,


UCORD.

2.

If PARAM, UCORD is not specified, CID = -1, or CID


given is not found, all values are calculated relative
to the basic coordinate system.

3.

If PARAM, GRDPNT is not specified in the input deck,


then the center of gravity and moment of inertia are
not output regardless of the value of PARAM, UCORD.

1602 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, GRIDFORM
Parameter

Values

Description

GRODFORM

< LONG, SHORT >


Default = SHORT

This parameter controls the output format of the


.grid file.
If LONG, the Large Field Fixed Format is used to
output the .grid file.
If SHORT (Default), the Fixed Format is used to
output the .grid file.

Altair Engineering

OptiStruct 13.0 Reference Guide 1603


Proprietary Information of Altair Engineering

PARAM, GYROAVG
Parameter
GYROAVG

Values

Description

<0, -1>
Default = 0

This parameter is used to select the frequency


response analysis formulation type for rotor dynamics
analysis.
PARAM, GYROAVG, 0
If this formulation is selected, the frequencydependent rotor dynamics terms are calculated for
each frequency. A frequency-dependent looping
option is activated, however, the run time is higher
compared to PARAM, GYROAVG, -1 as the calculation
process has to be repeated for each frequency in
the specified range.
PARAM, GYROAVG, -1
If this formulation is selected, frequency-dependent
looping does not occur and an average frequency
method is used to calculate the rotor dynamic terms.
The run time is lower compared to PARAM, GYROAVG,
0 as this option avoids intensive calculations for
each frequency. PARAM, WR3 and PARAM, WR4 must
be specified for this formulation to include rotor
damping.
Refer to the Users Guide section, Rotor Dynamics
for more details.

1604 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, HASHASSM
Parameter

Values

Description

HASHASSM

YES, NO
Default = NO

This parameter is used to enable the hash-table based


assembly method.
The hash-table based assembly method reduces the
memory requirement of the assembly module by about a
factor of 3 for linear static analyses, by about a factor of
5 for eigenvalue analyses, and by about a factor of 7 for
frequency response analyses involving material damping.
The reduction in the overall memory requirement is
problem-dependant. For problems where modules other
than the assembly module are dictating the overall
memory requirement, using this alternative assembly
method will not result in a reduction in the overall memory
requirement.
Using the hash-table based assembly method while
possibly reducing memory requirements may result in
longer run times.
If YES, hash-table based assembly method is used.
If NO, hash-table based assembly method is not used.

Altair Engineering

OptiStruct 13.0 Reference Guide 1605


Proprietary Information of Altair Engineering

PARAM, HFREQ
Parameter

Values

Description

HFREQ

Real>
(Hertz)

Modes with frequencies higher than HFREQ are not used


in Modal Frequency Response and Modal Transient
Analysis.

Default = None
Defaults

HFREQ is used in Response Spectrum Analysis to specify


the upper bound of the frequency range of interest for
modal combination.

If PARAM,
HFREQ is input Note:
without
1. The Residual Vector (RESVEC) calculation still
specifying a
includes the modes above HFREQ so that they are
value, then the
normalized correctly.
solution runs
into an error
2. Modes that are eliminated by PARAM, HFREQ will
display:

a) an S next to the mode number if the mode is


eliminated by MODESELECT in one subcase and
PARAM, HFREQ in another subcase, or
b) an H next to the mode number if the mode is
eliminated only by PARAM, HFREQ.

1606 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, HFREQFL
Parameter

Values

Description

HFREQFL

Real>
(Hertz)

Modes with frequencies greater than HFREQFL are not


used in Coupled Modal Frequency Response Analysis.
HFREQFL can be used to remove Rigid Body Modes from
the Modal Space.

Default = None
Defaults
If PARAM,
HFREQFL is
input without
specifying a
value, then the
solution runs
into an error

Altair Engineering

Note: Modes that are eliminated by PARAM, HFREQFL will


display an H next to the mode number.

OptiStruct 13.0 Reference Guide 1607


Proprietary Information of Altair Engineering

PARAM, I64SLV
Parameter

Values

Description

I64SLV

YES, NO
Default = NO

This parameter is used to enforce the activation of


internal long (64-bit) integer sparse direct solver. With
automatic memory allocation mode, the solver
automatically decides whether or not to switch the 64-bit
integer solver on. However, even if the 64-bit integer
solver is not the preferred choice in certain scenarios,
this parameter can still be used to enforce activation.
YES: the long (64-bit) integer sparse direct solver is
used.
NO: the short (32-bit) integer sparse direct solver is
used.

1608 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, INREL
Parameter

Values

Description

INREL

< 0, -1, -2 >

INREL controls the calculation of inertia relief.

Default = 0, for
static subcases

-2 requests inertia relief analysis without the need


for a SUPORT/SUPORT1 entry.

Default = -2, for


modal frequency
response subcases

-1 requests that inertia relief be performed.


SUPORT or SUPORT1 cards are required in the bulk
data section to restrain rigid body motion. The total
number of degrees-of-freedom specified on SUPORT
and SUPORT1 cards must be less than or equal to
six.
0 requests that constrained analysis be performed.
SUPORT and SUPORT1 cards are treated like SPC in
this case.

Altair Engineering

OptiStruct 13.0 Reference Guide 1609


Proprietary Information of Altair Engineering

PARAM, ITAPE
Parameter

Values

Description

ITAPE

-1, 0
Default = -1

If ITAPE = -1, then the Tape Label is written at the


beginning of the OUTPUT2 results file.

1610 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, INTRFACE
Parameter

Values

Description

INTRFACE

YES, NO
Default = YES

If YES, OptiStruct generates the .interface file which


contains data about the Fluid-Structure Coupling. The
.interface file can then be loaded into HyperMesh to
verify if the Fluid and Structure meshes are properly
connected at the interface. The parameters that
determine the Fluid-Structure coupling are set in the
ACMODL Data.
If NO, the .interface file is not generated.

Comments
1.

When the fluid domain is represented by an MFLUID card, and PARAM, INTRFACE, YES is
specified, OptiStruct generates the .wetel file which contains data about the wet
elements resulting from MFLUID cards. The .wetel file can then be loaded into HyperMesh
to visualize the locations of submerged/damp elements in the model.

Altair Engineering

OptiStruct 13.0 Reference Guide 1611


Proprietary Information of Altair Engineering

PARAM, K4CUTOFF
Parameter

Values

Description

K4CUTOFF

<Real>
Default = 0.1

PARAM, K4CUTOFF relates to the FastFRS interface.


If the low rank representation for the structural damping
matrix is selected, a cut-off value must be set. The
value is set using K4CUTOFF.
Refer to the Users Guide section, FastFRS Usage (Fast
Frequency Response Solver) for more details.

1612 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, KDAMP
Parameter

Values

Description

KDAMP

< 1, -1 >
Default = 1

If KDAMP is set to 1, modal damping is entered into the


complex stiffness matrix as material damping.
If KDAMP is set to 1, modal damping is entered into the
complex stiffness matrix as viscous damping.
Note:
To achieve identical displacements in Modal frequency
response or Modal transient analyses when the SDAMPING
subcase information entry is used instead of PARAM, G, the
steps described here can be followed:

Altair Engineering

1.

The TYPE field in the TABDMP1 bulk data entry should


be set to CRIT. This TABDMP1 bulk data entry is
referenced by the SDAMPING subcase information entry.

2.

Set the damping value (field gi) in the TABDMP1 bulk


data entry equal to half of the value of PARAM, G (that
is set the constant value to C/C0).

3.

Set PARAM, KDAMP,-1 (See description above).

OptiStruct 13.0 Reference Guide 1613


Proprietary Information of Altair Engineering

PARAM, KGRGD
Parameter

Values

Description

KGRGD

YES, NO
Default = NO

If YES, the rigid elements contribution to the geometric


stiffness matrix is included. This may result in missing
buckling modes that are found in other codes.
If NO, the rigid elements contribution to the geometric
stiffness matrix is omitted. This is the default.

1614 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, LFREQ
Parameter

Values

Description

LFREQ

<Real>
(Hertz)

Modes with frequencies less than LFREQ are not used in


Modal Frequency Response and Modal Transient Analysis.
LFREQ can be used to remove Rigid Body Modes from the
Modal Space.

Default = None
Defaults
If PARAM,
LFREQ is input
without
specifying a
value, then the
solution runs
into an error.

LFREQ is used in Response Spectrum Analysis to specify


the lower bound of the frequency range of interest for
modal combination.
Note:
1.

The Residual Vector (RESVEC) calculation still includes


the modes below LFREQ so that they are normalized
correctly.

2.

Modes that are eliminated by PARAM, LFREQ will


display:
a) an S next to the mode number, if the mode is
eliminated by MODESELECT in one subcase and
PARAM, LFREQ in another subcase, or
b) an L next to the mode number, if the mode is
eliminated only by PARAM, LFREQ.

Altair Engineering

OptiStruct 13.0 Reference Guide 1615


Proprietary Information of Altair Engineering

PARAM, LFREQFL
Parameter

Values

Description

LFREQFL

Real>
(Hertz)

Modes with frequencies less than LFREQFL are not used


in Coupled Modal Frequency Response Analysis. LFREQFL
can be used to remove Rigid Body Modes from the Modal
Space.

Default = None
Defaults
If PARAM,
LFREQFL is
input without
specifying a
value, then the
solution runs
into an error

Note: Modes that are eliminated by PARAM, LFREQFL will


display an L next to the mode number.

1616 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, LGDISP
Parameter

Values

Description

LGDISP

<0, 1, -1>
Default = 0

If LGDISP = 1, Large displacement nonlinear static analysis


is activated. The corresponding nonlinear solution
parameters should be specified in the NLPARM bulk data
entry.
If LGDISP = 0 or -1, Large displacement nonlinear static
analysis is deactivated (Small displacement nonlinear static
analysis is the default). The corresponding nonlinear
solution parameters should be specified in the NLPARM bulk
data entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1617


Proprietary Information of Altair Engineering

PARAM, LMSOUT
Parameter

Values

Description

LMSOUT

<YES, NO,
This parameter controls the output of the condensed flex
STRESS>
body modes, full diagonal mass matrix, and modal stresses
Default = NO to the .op2 file.
If YES, the condensed flex body modes and the full diagonal
mass matrix are output to the .op2 file.
If STRESS, the modal stresses are also output to the .op2
file.
If NO, the condensed flex body modes, full diagonal mass
matrix and the modal stresses are not output to the .op2
file.

1618 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, LOWRANK
Parameter

Values

Description

LOWRANK

<0,-1 or 1> PARAM, LOWRANK relates to the FastFRS interface.


Default = 0
It indicates to FastFRS which solution strategy to use to
handle the modal structural damping matrix.
If the value is 0, then FastFRS computes a full eigensolution
using the data found in either the optimization FSPSD data
block or the diagonal stiffness and structural damping data
blocks.
If the value is -1, a low rank representation of the matrix
found in structural damping is used.
A special case of this option occurs when acoustic fluid is
present in the model and the matrices found in the fluid
mass matrix, fluid stiffness matrix, and fluid viscous damping
matrix data blocks are all diagonal. FastFRS takes
advantage of this special case when the value of LOWRANK
is set to 1 by treating the matrix found in the structural
damping data block and the fluid matrices as low rank
representations. Note that for optimization problems, the
mass and stiffness matrices are full and a low rank
representation cannot be used.
Refer to the Users Guide section, FastFRS Usage (Fast
Frequency Response Solver) for more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1619


Proprietary Information of Altair Engineering

PARAM, MASSDMIG
Parameter

Values

Description

MASSDMIG

YES, NO
Default = NO

For static condensation with ASET of a static loadcase,


the reduced stiffness matrix [k] and load vector {p} are
created. If the reduced mass matrix is also desired,
then set PARAM, MASSDMIG to YES.

1620 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, MAXDAMP
Parameter
MAXDAMP

Values

Description

<Integer>
Default = 400

Identifies the maximum number of viscous residual vectors


that are to be calculated. If MAXDAMP is exceeded, a
WARNING message is issued and no viscous residual
vectors are calculated.
Solution times can be greatly extended due to the
calculation of large numbers of viscous residual vectors, if
this is not intended by the user.

Altair Engineering

OptiStruct 13.0 Reference Guide 1621


Proprietary Information of Altair Engineering

PARAM, MBDH3D
Parameter

Values

Description

MBDH3D

NODAL, MODAL,
BOTH, NONE
Default = BOTH

This parameter controls the type of results output


to the .h3d results format for MBD analyses.
If NODAL, nodal based results are output to the
.h3d results file.
If MODAL, modal based results are output to the
_mbd.h3d results file.
If BOTH, nodal results are output to the .h3d
results file and modal results are output to the
_mbd.h3d file.
If NONE, MBD results are not output to either the
.h3d or _mbd.h3d results file.
Note: If the HyperMesh output format is requested,
nodal based results will be output to the
.res file, regardless of this parameter
setting.

1622 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, MBDREC
Parameter

Values

Description

MBDREC

YES, NO
Default = NO

PARAM, MBDREC creates two flexible body files


during Component Mode Synthesis (CMS).
A small *.h3d is generated that contains the
minimum amount of information required for MBD
simulation in MotionSolve.
A larger file *_recov.h3d will also be generated that
contains the information from the small file as well as
recovery information for displacement, velocity,
acceleration, stress, and strain.
The large file is used along with the MotionSolve
calculated result (.mrf) file specified with the
ASSIGN, MBDINP data in an OptiStruct transient
analysis to recover displacement, velocity,
acceleration, stress, and strain results of the flex
body. These results can be output in the .op2 and
.h3d files.
See the Users Guide entry on Flexible Body
Generation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1623


Proprietary Information of Altair Engineering

PARAM, MEMTRIM
Parameter
MEMTRIM

Values

Description

YES, NO
This parameter is used to activate/deactivate the memory
Default = YES trim feature for AMLS runs.
AMLS is an external program that requires its own memory
and disk space to perform eigenvalue analysis. Without
memory trim, the total memory requirement (T) to perform
eigenvalue analysis using AMLS was the sum of the memory
required by OptiStruct (O), the memory exclusively
allocated for AMLS (A), and other miscellaneous memory
requirements; for example, MIO library requirement, (M).
Thus:
T = O + A + M.
With memory trim enabled, the total memory requirement is
reduced to:
T = max(O,A) + M.
If YES, memory trim is active.
If NO, memory trim is inactive.

1624 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, MFILTER
Parameter

Values

Description

MFILTER

<0.0 < real


number < 1.0>

This parameter defines a threshold for the mode tracking


matrix to check eigenvector correspondence.

Defaults:

If an entry of the mode tracking matrix is greater than


the specified threshold, the eigenvectors of previous and
current iterations (corresponding to the row number and
column number of the entry) are assumed to have
correspondence.

-If this
parameter is
included in the
input file, but, no
value is
provided, then
running the
program will
result in an
error. In such
cases a real
value between
0.0 and 1.0 must
be specified.
- If this
parameter is not
included in the
input file, then:

If PARAM, TRAKMETH is set to 0, the mass matrix based


cross-orthogonality criterion (CORC) is used to check for
eigenvector correspondence, and PARAM, MFILTER is set
to 0.7.
If PARAM, TRAKMETH is set to 1, the modal assurance
criterion square root (MACSR) is used, and PARAM,
MFILTER is set to 0.7.
If PARAM, TRAKMETH is set to 2, the modal assurance
criterion (MAC) is used and PARAM, MFILTER is set to be
0.5.

The value of
PARAM,
MFILTER is
equal to 0.7 if
PARAM,
TRAKMETH is
set to 0 or 1.
The value of
PARAM,
MFILTER is
equal to 0.5 if
PARAM,
TRAKMETH is
set to 2.

Altair Engineering

OptiStruct 13.0 Reference Guide 1625


Proprietary Information of Altair Engineering

PARAM, MODETRAK
Parameter

Values

Description

MODETRAK

-1, 0, 1, YES,
NO
Default = NO

If -1, 0 or NO, mode tracking is not used. Mode numbers


are determined by frequency.
If 1 or YES, mode tracking is used. Mode numbers are
tracked by comparing eigenvectors between iterations.
Concerning mode tracking, the following symbols are used
in the output format:

Indicates that the tracked mode was not found in


the modes retrieved for that iteration. If this mode
is not a part of the objective, optimization will
continue and mode will be tracked if found in later
iterations, otherwise optimization will stop. If
optimization is halted for this reason, increase the
number of modes or range of modes being retrieved.

Indicates that the tracked mode was found but


does not correlate well with the original mode.
Optimization will continue.

Note: In topology optimization, mode shapes can


change greatly due to the reorganization of
material within the design domain. For some
models, mode tracking may be of limited
effectiveness. Also, the values of optimized
modes may increase substantially during the
optimization process. You are advised to provide
a wide range or large number of modes in the
EIGRL card to protect against optimized modes
being lost.
Note: This parameter is ignored if a MODTRAK subcase
information entry is present in the input.

1626 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, NEGMASS
Parameter
NEGMASS

Values

Description

0, 1
Default = 0

This parameter is used to check for negative


diagonal mass.
If 0, an error termination will occur if negative
diagonal mass is discovered.
If 1, negative diagonal mass or inertia from CONM2 is
allowed.

Altair Engineering

OptiStruct 13.0 Reference Guide 1627


Proprietary Information of Altair Engineering

PARAM, NLAFILE
Parameter
NLAFILE

Values

Description

<YES, NO>
Default = NO

This parameter controls the output of animation files (A-File)


in geometric nonlinear analysis.
If YES, the animation files are retained after geometric
nonlinear analysis;
If NO, the animation files are removed after geometric
nonlinear analysis.

1628 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, NLFAT
Parameter
NLFAT

Values

Description

<YES, NO>
Default = NO
Defaults:
1. If this
parameter
does not
exist in the
deck, the
default
behavior is
NO.
2. If this
parameter
exists in the
deck,
however, no
value (YES/
NO) is
specified,
then the
default
behavior is
NO.

PARAM, NLFAT, YES, forces OptiStruct to run models in which


fatigue solutions (using the FATLOAD entry) reference
nonlinear quasi-static analysis (NLSTAT) subcases.
PARAM, NLFAT, NO, does not allow NLSTAT subcases to be
referenced by the FATLOAD data entry and the solution
errors out if such models are run.
Note:
PARAM, NLFAT, YES can be introduced to force OptiStruct to
run fatigue analysis based on a nonlinear subcase
(ANALYSIS=NLSTAT). Nonlinear analysis results are not
recommended for use in a fatigue analysis because
nonlinear stresses and strains cannot be scaled and
superimposed, however, acceptable results may be generated
in the following cases:
During a nonlinear run (ANALYSIS=NLSTAT),
acceptable results may be generated if a model uses
elasto-plastic material and NEUBER correction is turned
OFF (Plasticity field on FATPARM bulk data entry). This
statement is based on the assumption that nonlinear
analysis is run until shakedown is achieved. If strain
results from the nonlinear analysis are used prior to
shakedown, the fatigue results will most likely be
incorrect since the magnitude of plastic strain may not
be close to the steady state strain value.
Additionally, acceptable results may be generated if
contact based nonlinearity exists in the model
(ANALYSIS=NLSTAT) and the contact area is not
expected to change appreciably as the load increases
(for example, surfaces that match from the beginning).
In both cases, the Scale and Offset fields on the FATLOAD
entry should be left blank as the stresses and strains cannot
be scaled and superimposed.
Regardless of the model type, fatigue results based on
nonlinear results using PARAM, NLFAT, YES should always be
interpreted with caution.

Altair Engineering

OptiStruct 13.0 Reference Guide 1629


Proprietary Information of Altair Engineering

PARAM, NLRFILE
Parameter
NLRFILE

Values

Description

<YES, NO>
Default = NO

This parameter controls the output of restart files (R-File) in


geometric nonlinear analysis.
If YES, the restart files are retained after geometric
nonlinear analysis;
If NO, the restart files are removed after geometric
nonlinear analysis.

1630 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, NLRUN
Parameter
NLRUN

Values

Description

<YES, NO>
Default = YES

The parameter controls if geometric nonlinear analysis


subcases run automatically after these subcases in bulk
format are converted into block format.
If YES, geometric nonlinear analysis subcases run
automatically after conversion.
If NO, geometric nonlinear analysis subcases do not run
automatically after conversion.

Altair Engineering

OptiStruct 13.0 Reference Guide 1631


Proprietary Information of Altair Engineering

PARAM, NPRBAR
Parameter
NPRBAR

Values

Description

<INTEGER>
Default = 3

Controls the number of the output INFORMATION #741 for


RBAR elements.
Example of INFORMATION #741,
*** INFORMATION # 741
No need to constrain the rotational dof of this dependent
grid.
RBAR element id = 20436260
independent grid id = 20374048
dependent grid id = 20367448
This is because there isn't any stiffness and load on the
rotational dof of the dependent grid.

1632 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, NPRBE2
Parameter
NPRBE2

Values

Description

<INTEGER>
Default = 3

Controls the number of the output INFORMATION #741 for


RBE2 elements.
Example of INFORMATION #741,
*** INFORMATION # 741
No need to constrain the rotational dof of this dependent
grid.
RBE2 element id = 20436260
independent grid id = 20374048
dependent grid id = 20367448
This is because there isn't any stiffness and load on the
rotational dof of the dependent grid.

Altair Engineering

OptiStruct 13.0 Reference Guide 1633


Proprietary Information of Altair Engineering

PARAM, NPRGDE
Parameter
NPRGDE

Values

Description

<INTEGER>
Default = 3

Controls the number of the output INFORMATION #742.


Example of INFORMATION #742,
*** INFORMATION # 742
The dependent rotational dof of this rigid element is
removed.
RBE2 element id = 20436262
independent grid id = 20374050
a dependent grid id = 20367345
This is because there is no need to constrain the rotational
dof of any of the dependent grids.

1634 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, NUMEG
Parameter
NUMEG

Values
<Integer>
1000

Altair Engineering

Description
When ND on the EIGRL/EIGRA data is blank, the disk space
estimate in the .out file for modal frequency response and
the transient analysis is based on the number of modes
specified by PARAM,NUMEG. When Lanczos is used, the disk
space estimate is based on this value plus the number of the
potential residual vectors. When AMLS/AMSES is used, the
disk space estimate is based only on the value of
PARAM,NUMEG. In this case, it is assumed that
PARAM,NUMEG includes the number of potential residual
vectors.

OptiStruct 13.0 Reference Guide 1635


Proprietary Information of Altair Engineering

PARAM, OGEOM
Parameter

Values

Description

OGEOM

<YES, NO>
Default = YES

PARAM, OGEOM controls the output of model (geometry)


data to the .op2 file. This functionality is also
controlled by the MODEL/NOMODEL option on the
OUTPUT, OP2 I/O option, but this parameter setting will
override the OUTPUT, OP2 setting.
PARAM, OGEOM, YES will output model data to the .op2
file.
PARAM, OGEOM, NO will not output model data to the
.op2 file.

1636 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, OMACHPR
Parameter

Values

Description

OMACHPR

<YES, NO>
Default = NO

PARAM, OMACHPR controls the Nastran version for some


OP2 datablocks.
YES means that the new Nastran version should be used.
NO means that the old Nastran version should be used.

Altair Engineering

OptiStruct 13.0 Reference Guide 1637


Proprietary Information of Altair Engineering

PARAM, OMID
Parameter

Values

Description

OMID

<YES, NO>
Default = YES

Controls the coordinate system used by shell and


membrane elements for stress and strain results.
This affects the recovery of optimization responses as
well as results output to the HM, PUNCH, and OPTI
output formats.
Stress and strain results are always output to OUTPUT2
and H3D output formats with reference to the elemental
system.
YES indicates that shell and membrane stresses/strains
are with reference to the material coordinate system, as
defined by the MID/THETA field of the element card.
NO indicates that shell and membrane stresses/strains are
with reference to the elemental coordinate system,
regardless of what is defined on the MID/THETA field of
the element card.

1638 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, OP2GM34
Parameter

Values

Description

OP2GM34

<TRUE, FALSE> PARAM, OP2GM34 controls the output of GEOM3 and


Default = TRUE GEOM4 data blocks to the .op2 file if PARAM, POST, -1 is
specified.
PARAM, OP2GM34, TRUE will output GEOM3 and GEOM4
data blocks to the .op2 file if PARAM, POST, -1 is
specified.
PARAM, OP2GM34, FALSE will not output GEOM3 and
GEOM4 data blocks to the .op2 file.

Altair Engineering

OptiStruct 13.0 Reference Guide 1639


Proprietary Information of Altair Engineering

PARAM, PLIGEXT
Parameter

Values

Description

PLIGEXT

<YES, NO>
Default = NO

This parameter is used to print the applied load vector in


DMIG form to the .pligext file. The DMIG NAME is
PLIGEXT.
To generate the .pligext file the oload(opti)=all
command must also be requested.

1640 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, POST
Parameter

Values

Description

POST

<0, -1, -2, -5>


Default = 0

Adding PARAM, POST to the bulk data section of the


input deck will activate the creation of the .op2 file.
PARAM, POST, -1 will create the .op2 file with
displacement results output in the analysis system
and PARAM, ITAPE set to -1.
PARAM, POST, -2 will create the .op2 file with
displacement results output in the basic coordinate
system and PARAM, ITAPE set to 0. The GEOM3,
GPDT and GPL data blocks are also included in the
.op2 file when PARAM, POST, -2 is used.
PARAM, POST, -5 will write the stiffness and mass
matrices to the .k.op2 and the .m.op2 files,
respectively, in addition to creating the .op2 file with
displacement results output in the analysis system
and PARAM, ITAPE set to -1.

Altair Engineering

OptiStruct 13.0 Reference Guide 1641


Proprietary Information of Altair Engineering

PARAM, POSTEXT
Parameter

Values

Description

POSTEXT

YES, NO
Default = NO

If PARAM,POSTEXT,YES, the modal complex stiffness matrix


(KHH) and, if it exists, the modal viscous damping matrix
(BHH) are written to the .op2 file when frequency
response analysis is performed.
The modal complex stiffness matrix is:

Where G is the PARAM,G structural damping value and


[Kge] is the structural damping matrix based on the
structural damping values on the MATi data.
The modal viscous damping matrix is:

1642 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, PRESUBNL
Parameter
PRESUBNL

Values

Description

YES, NO
Default = NO
Defaults:
If this
parameter
does not exist
in the deck,
the default
behavior is NO.
If this
parameter
exists in the
deck,
however, no
value (YES/
NO) is
specified,
then the
default
behavior is NO.

Altair Engineering

PARAM, PRESUBNL, YES forces OptiStruct to run models, in


which Linear Buckling Analysis or Preloaded Analysis is
defined, in conjunction with nonlinear materials (MATS1,
MATHE, or MGASK) or large displacement nonlinear
analysis.
PARAM, PRESUBNL, NO does not allow Linear Buckling
Analysis or Preloaded Analysis with nonlinear materials or
large displacement nonlinear analysis to be defined and the
solution errors out if such models are run.
Note: Linear Buckling Analysis or Preloaded Analysis is not
recommended in models with nonlinear materials or
large displacement nonlinear analysis. It is the users
responsibility to interpret such results with caution.

OptiStruct 13.0 Reference Guide 1643


Proprietary Information of Altair Engineering

PARAM, PRGPST
Parameter
PRGPST

Values

Description

< YES, NO, ALL,


PRGPST controls the printing of AUTOSPC information
NONE,< number of to the .out file.
DOFs> >
PARAM, PRGPST, YES
Default = YES

A maximum of 100 degrees of freedom (DOF) of


AUTOSPC data will be printed in the .out file.
PARAM, PRGPST, NO
No AUTOSPC data will be printed.
PARAM, PRGPST, NONE
Works exactly like PARAM, PRGPST, NO - No AUTOSPC
data will be printed.
PARAM, PRGPST, ALL
All AUTOSPC data will be printed in the .out file.
PARAM, PRGPST, <number of DOF>
A maximum of <number of DOF> degrees of freedom
(DOF) of AUTOSPC data will be printed in the .out file.

1644 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, PRINFACC
Parameter
PRINFACC

Values

Description
If 1, the inertia relief rigid body forces and
accelerations are printed to the .out file.

<1, 0>
Defaults
1. The default is
0, when the
parameter is
not present in
the deck.

If 0, the inertia relief rigid body forces and


accelerations are NOT printed to the .out file.

2. The default is
1, when
PARAM,
PRINFACC is
input without
specifying a
value.

Altair Engineering

OptiStruct 13.0 Reference Guide 1645


Proprietary Information of Altair Engineering

PARAM, RBE2FREE
Parameter

Values

Description

RBE2FREE

<YES, NO>

Modeling errors can result in the creation of RBE2 elements


with rigid body rotations. This parameter can be used to
convert ERROR 725 into WARNING 825 when singular RBE2
elements, with rotational rigid body modes in all three
directions, are present in the model.

Default = NO

YES
If PARAM, RBE2FREE, YES is specified, ERROR 725 is
converted into WARNING 825. For AMSES/AMLS SUBCASEs
the free rotational degrees of freedom are AUTOSPCed.
For static analysis and Lanczos eigenvalue analysis, the
run may fail due to singularities and ERROR 153 or 155 will
be issued.
NO
If PARAM, RBE2FREE, NO is specified, ERROR 725 is not
converted into WARNING 825 and models containing
singular RBE2 elements will error out.
Note:
To solve a problem with Lanczos or static analysis, AMSES
can used first to determine which RBE2 degrees of freedom
are AUTOSPCed. Single point constraints (SPC) can be
added to manually constrain such degrees of freedom in
subsequent static analysis or Lanczos eigenvalue analysis.

1646 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, RBE3FREE
Parameter

Values

Description

RBE3FREE

<YES, NO>

Modeling errors can result in the creation of RBE3 elements


with free spiders. This parameter can be used to convert
ERROR 772 into WARNING 824 when free spiders on RBE3
elements are present in the model. These free spiders may
contain singular degrees of freedom.

Default = NO

YES
If PARAM, RBE3FREE, YES is specified, ERROR 772 is
converted into WARNING 824.
For AMSES/AMLS runs the free spiders will be AUTOSPCed
if they are singular. This will cause invalid results as the
RBE3 will be constrained to ground. Check the AUTOSPC
output to make sure the free spiders are not AUTOSPCed.
If the free spiders are singular, Lanczos eigenvalue
solutions and static analysis runs will fail with ERRORs 155
or 153.
NO
If PARAM, RBE3FREE, NO is specified, ERROR 772 is not
converted into WARNING. Models containing RBE3 elements
with free spiders will error out.

Altair Engineering

OptiStruct 13.0 Reference Guide 1647


Proprietary Information of Altair Engineering

PARAM, RBMEIG
Parameter

Values

Description

RBMEIG

<REAL>
Default = 1.0

PARAM, RBMEIG defines the cutoff eigenvalue for


determination of rigid body modes calculated by the AMLS
and AMSES eigensolvers.

Default

Note:
The default
1. PARAM, RBMEIG functions in a similar manner to
cutoff
PARAM, FZERO, which is used in models solved by the
eigenvalue
Lanczos eigensolver.
(AMSES and
AMLS) is 1.0, if 2. The default cutoff eigenvalue of 1.0 is equivalent to a
this parameter
natural frequency of 0.16 Hz.
is not present
in the deck.
3. For the Lanczos eigensolver, use PARAM,FZERO to set
the cutoff frequency for rigid body modes.

1648 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, REANAL
Parameter
REANAL

Values

Description

0.0 < Real < 1.0


No default

This parameter is for restart runs of topology


optimizations only.
Inclusion of this parameter on a restart run will cause
the last iteration to be reanalyzed without penalization.
If the value given is less than the value of MINDENS
(default = 0.01) used in the optimization, all elements
will be assigned the densities they had during the final
iteration of the optimization. As there is no
penalization, stiffness will now be proportional to
density.
If the value given is greater than the value of MINDENS,
those elements whose density is less than the given
value will have density equal to MINDENS, all others will
have a density of 1.0.

Altair Engineering

OptiStruct 13.0 Reference Guide 1649


Proprietary Information of Altair Engineering

PARAM, RECOVER
Param
eter

Value
s

RECOVE <LB,
UB>
R

Description

<LB, UB>:
They represent the Lower Bound (LB) and the Upper Bound (UB) of
the frequencies between which the full-structure mode shapes are
requested instead of the modes of the condensed system generated
during Component Mode Synthesis (CMS).
LB (real > 0.0, optional):
Mode shapes of the full-structure, at frequencies greater than LB,
will be output to the .op2 file.
UB (real > 0.0, mandatory):
Mode shapes of the full-structure, at frequencies lower than UB, will
be output to the .op2 file.
Note:
1.

The following example implementations are incorrect and will


result in an ERROR:
PARAM, RECOVER, 30.0, 20.0 (as UB < LB)
PARAM, RECOVER, ,0.0 (as UB 0)

Defaults
1.

The mode shapes of the condensed system (only) generated during CMS are output when
this parameter is not present in the deck.

2.

If PARAM, RECOVER is input without specifying a value, the program results in an ERROR.

3.

LB is optional and the default for LB is 0.0, if it is left blank.

1650 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, RENUMOK
Parameter
RENUMOK

Values

Description

<YES, NO,
BLANK>
Default = NO

If YES or BLANK, when the solid element grids are listed


in the order that would make the element inside out,
they are automatically re-ordered. In this way, running
(importing and exporting) the model through HyperMesh
to get the corrected element grid sequence can be
avoided.
If NO, when the element grids are input in reverse
order, they are not re-sequenced to the correct order.
OptiStruct will error out if such element grid ordering
exists.
Note:
1.

If the element grids are input in a random order,


then PARAM, RENUMOK will not be able to correct
the sequence. OptiStruct will error out in such
cases.

2. If PARAM, RENUMOK is not specified (default), then


the default is NO. This is different from specifying
PARAM, RENUMOK and leaving the value field blank,
which implies YES.
3. If PARAM,RENUMOK is used and the .fem file is used
for the model information file in HyperView, then
corner stresses for the solid elements will be wrong
when the .h3d or .op2 files are used for the results
file. So, if PARAM,RENUMOK is used, HyperView
should use the .op2 or .h3d file for the model
information file.

Altair Engineering

OptiStruct 13.0 Reference Guide 1651


Proprietary Information of Altair Engineering

PARAM, RFIOUT
Parameter
RFIOUT

Values

Description

<YES, NO>
Default = NO

This parameter controls the output of modal super


element for use in the RecurDyn multibody dynamics
software from FunctionBay. This information is written
to the .rfi file. This should be used with CMSMETH
CBN and ASET DOF for the connection points.
If YES, the modal super element is output to the .rfi
file.
If NO, the .rfi file is not created.
Note:
This .rfi file can be created only by OptiStruct
executables running on 64-bit Windows machines. This
file cannot be created while using OptiStruct on Linux or
Mac OS X machines.

1652 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, RHOCP
Parameter

Values

Description

RHOCP

Real > 0.0


Default = 1.0

The scale factor used to calculate ERP in decibels (dB).


The calculation is:

Altair Engineering

OptiStruct 13.0 Reference Guide 1653


Proprietary Information of Altair Engineering

PARAM, RSPLICOR
Parameter
RSPLICOR

Values

Description

0, 1, REAL > 1.0


Default = 0

RSPLINE end rotation correction.


0: No correction
1: two RSPLINE ends have rotation correction
>1: Defines cut-off angle. Two RSPLINE ends have
rotation correction. If two consecutive RSPLINE
sections have an angle larger then the cut-off angle,
rotation correction is applied to the shared RESPLINE
node.

1654 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SEP1XOVR
Parameter
SEP1XOVR

Values

Description

0, 16
Default = 0

The old and new location of moved shell grid points are
printed if SEP1XOVR = 16. When the RSSCON shell-tosolid element connector is used. By default, the moved
shell grid points are not printed, SEP1XOVR = 0.
See the description of PARAM,TOLRSC for more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1655


Proprietary Information of Altair Engineering

PARAM, SEPLOT
Parameter
SEPLOT

Values

Description

<YES, NO>
Default = YES
Defaults:

PARAM, SEPLOT can be used during CMS analysis (only


with the CBN method) to create a .seplot file that
contains the ASET grid data as well as the GRID and
PLOTEL data defined using the MODEL I/O Option. The
data is written to the .seplot file in OptiStruct.

The value of this


parameter is YES,
YES: The .seplot file is created.
if it is included in
the input file, but
NO: The .seplot file is not created.
no value is
provided.
The value of this
parameter is NO,
if it is not
included in input
file.

1656 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SH4NRP
Parameter
SH4NRP

Values

Description

0, 1, 2

This parameter controls the full projection of 4-node shell


elements in NLGEOM implicit analysis.

Default = 0 in
NLGEOM
subcase
Default = 1 in
IMPDYN
subcase

If 0, the full projection for warped QEPH shell elements will


be deactivated. This option may improve the implicit
nonlinear analysis with QEPH warped shell elements if the
rigid rotation of warped elements is small enough.
If 1, the full projection for warped elements will be applied
only for internal force calculation; the option gives
accurate results if it converges successfully, but
convergence issue could be encountered with very warped
elements.
If 2, the full projection for warped QEPH shell elements will
be activated for the stiffness matrix to stay consistent
with the internal force calculation. This option can
improve the convergence of implicit nonlinear analysis with
QEPH warped shell elements at the cost of some additional
calculations.
In the case of finite rigid rotations with warped shell
elements, PARAM, SH4NRP, 1 gives accurate results. If
convergence difficulties are encountered, PARAM, SH4NRP,
2 should be used.
If PARAM SMDISP 1 is present, SH4NRP is always set as 0
internally.

Altair Engineering

OptiStruct 13.0 Reference Guide 1657


Proprietary Information of Altair Engineering

PARAM, SHELOS11
Parameter
SHELOS11

Values

Description

YES, NO
Default = NO

YES can be used to restore the formulation used in version


11.0.240 and earlier for first-order shell elements (CQUAD4
and CTRIA3).
Note: In Release 12.0 the first order shell elements have
been improved to:
Eliminate inaccuracies in transverse shear and
inter-laminar stress calculation that could occur for
cases with membrane-bending coupling, especially
composites.
Improve robustness and stability of buckling
formulation by changing the default order for plate
buckling to first order.
The behavior of shells from earlier releases can be
recovered using this parameter.

1658 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SHL2MEM
Parameter

Values

Description

SHL2MEM

<Real Number >


0.0>

A shell property (defined by the PSHELL bulk data


entry) is automatically converted into a membrane
property if the membrane thickness (field T) of the
PSHELL bulk data entry is less than or equal to the
value specified using PARAM, SHL2MEM. This is done by
setting MID2 and MID3 to blank for the PSHELL.

No default
(see note 6)

Note:
1. With regard to determining the conversion from a
PSHELL shell to membrane property, the nodal
thicknesses defined using the Ti fields of the
CTRIA3/6 or the CQUAD4/8 bulk data entries are
ignored.
2. If the value of the field T in the referenced PSHELL
entry is less than or equal to the value of
PARAM,SHL2MEM then the shell property is
converted to a membrane property regardless of
the Ti field values.
3. PARAM, SHL2MEM should be used with caution in
optimization runs, as this parameter will also apply
to design properties. If the shell thickness on such
design properties (in PSHELL) is lower than the
value specified with PARAM, SHL2MEM, they will
automatically be converted to membrane properties
(regardless of the value of their corresponding
design variables).
4. If PARAM, SHL2MEM is used in optimization runs
with the shell thickness (T) of the PSHELL design
property equal to zero or blank, then the shell
property is automatically converted into a
membrane property.
5. PARAM, SHL2MEM is intended for use with skin
elements, which are useful for stress calculation on
the surface of solid (3D) elements.
6. Defaults:
If PARAM,SHL2MEM is input without specifying a
value, then the code will error out (no default).
If PARAM,SHL2MEM is not used, the conversion
from shell property to a membrane property will
not occur.

Altair Engineering

OptiStruct 13.0 Reference Guide 1659


Proprietary Information of Altair Engineering

PARAM, SHPBCKOR
Parameter
SHPBCKOR

Values

Description

1, 2
Default = 1

PARAM,SHPBCKOR defines the type and order of


approximation used in plate bending geometric stiffness for
linear shell elements (CQUAD4 and CTRIA3).
1: First order approximation, expressed using displacement
degrees of freedom in the geometric stiffness matrix. It is
more numerically stable and includes both bending and
transverse shear contributions. Being first order, this
option may over-estimate buckling loads, especially when
the mesh is coarse relative to the buckling wavelength
(only a few elements per wave length).
2: Second order approximation, expressed using rotational
degrees of freedom in the geometric stiffness matrix. This
option ignores contributions of transverse shear to
buckling.
Note:
Second order approximation is appropriate and provides
better accuracy for buckling of thin shells, which is
dominated by bending.
For thick shells or for composites with soft cores (where
transverse shear contributions are significant), it is
advisable to use PARAM,SHPBCKOR,1, which captures both
bending and transverse shear effects. Since
PARAM,SHPBCKOR,1 is more numerically stable, it can also
help if there are difficulties in the eigensolver.

1660 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SIMPACK
Parameter
SIMPACK

Values

Description

0, 1, 2, 3, 4
Default = 0

Requests generation of the SIMPACK .fbi file containing


flexible body information for SIMPACK analysis.
PARAM,SIMPACK,1
Writes CMS Matrices [k] and [m] to the SIMPACK
.fbi file.
Writes modes and eigenvectors of the SE to the
SIMPACK .fbi file.
PARAM,SIMPACK,2
This option writes out all the information specified in
PARAM, SIMPACK,1 (above) and additionally writes
model information to the SIMPACK .fbi file. See
Comment 2 about MODEL data.
PARAM,SIMPACK,3
This option writes out all the information specified in
PARAM, SIMPACK, 2 (above) to the SIMPACK .fbi
file and additionally includes the following:
Writes the Interior point recovery GRID SET to the
SIMPACK .fbi file.
Writes the Interior point recovery matrix to the to
the SIMPACK .fbi file.
PARAM,SIMPACK,4
This option writes out all the information specified in
PARAM, SIMPACK, 3 (above) to the SIMPACK .fbi
file and additionally includes the following:
Writes rotational forces to the SIMPACK .fbi file.

Comments
1.

Refer to the SIMPACK section of Coupling OptiStruct with Third Party Software in the
Users Guide for more information.

2.

If PARAM, SIMPACK, 2 is specified, the MODEL I/O Options Entry does not have any effect
on the output. The entire model is written to the SIMPACK .fbi file.

Altair Engineering

OptiStruct 13.0 Reference Guide 1661


Proprietary Information of Altair Engineering

PARAM, SMDISP
Parameter
SMDISP

Values

Description

< 0, 1 >
Default = 0

This parameter is used to specify that small displacement


formulation or large displacement formulation is used. It
affects Geometric Nonlinear Implicit Static Analysis
(ANALYSIS = NLGEOM) and Geometric Nonlinear Implicit
Dynamic Analysis (ANALYSIS = IMPDYN).
When large displacement effects are negligible, PARAM,
SMDISP, 1 could be used to improve the convergence and
performance.
If 0, use large displacement formulation.
If 1, use small displacement formulation.

1662 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SNAPTHRU
Parameter
SNAPTHRU

Values

Description

YES, NO
Default = NO

PARAM, SNAPTHRU controls the output of the forcedeflection curve in geometric nonlinear analysis.
If YES, the converter will generate rigid bodies internally
and output the time history for rigid body forces in the
Time-History (TH) file. This is valid only when grids are
defined on XHIST bulk data entry with TYPE = GRID and
ENTRY=DEF simultaneously. The force-deflection curve
can be cross plotted with the grid displacements and
corresponding rigid body forces in HyperGraph.
If NO, output of the force-deflection curve is not
requested and the internal rigid bodies are not generated.

Altair Engineering

OptiStruct 13.0 Reference Guide 1663


Proprietary Information of Altair Engineering

PARAM, SORTCON
Parameter

Values

Description

SORTCON

<Integer>
Default = 20

This parameter controls the output of violated constraints


to the .out file (and to screen).
By default, the 20 most violated constraints are printed in
a separate table and sorted by percentage violation. This
behavior can be modified with PARAM, SORTCON, N; where
N is the number of constraints to be printed. (N = 0
disables this feature).

1664 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SPLC
Parameter
SPLC

Values

Description

Real > 0.0


Default = 1.0

This parameter is used to specify the speed of sound used


in the wave number and the complex particle velocity
vector calculations, as shown below (see the Radiated
Sound Analysis section in the Users Guide for further
information):
Wave Number
The wave number k is defined as follows:

2 f
c

Where,
c is the speed of sound defined by PARAM, SPLC.

f is the frequency of the sound wave in the medium.


Complex Particle Velocity Vector
The complex particle velocity vector is defined for each
frequency as follows:

uuur
( pv) j ( f )

pj ( f ) X
j
c

i
krj

Where,

pj ( f )

is the complex acoustic pressure due to source grid

j at the microphone location.

X
j

is the unit vector from the source grid j to the


microphone grid

X
j

r
Xj
r
Xj

r
Xj
rj

(see Figure 1)

is the density of the acoustic medium defined by


PARAM, SPLRHO.

c is the speed of sound defined by PARAM, SPLC.


k is the wave number defined above under Wave Number.

rj

Altair Engineering

is the distance from the acoustic source grid j on the

OptiStruct 13.0 Reference Guide 1665


Proprietary Information of Altair Engineering

Parameter

Values

Description
panel to the microphone grid (see Figure 1).

i is the square root of -1


Note:
1.

This parameter is used to specify the speed of sound


used in Radiated Sound Analysis. The same value is
used in the Equivalent Radiated Power (ERP)
calculations (See PARAM, ERPC).

2.

If both PARAM, SPLC and PARAM, ERPC are specified in


the same input deck, then the last instance
dominates.

1666 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SPLFAC
Parameter
SPLFAC

Values

Description

Real > 0.0


Default = 1.0

This parameter specifies the scale factor (q ) used to


calculate the Sound Pressure Level in Radiated Sound
Analysis. The equation used for the calculation is:
Sound Pressure
Total Complex Acoustic Sound Pressure requested by SPL
is:
np

ptotal f
j 1

f q
V flux f
rj

ie

ikr j

Where,

f is the frequency of the sound wave in the medium.


is the density of the acoustic medium defined by
PARAM, SPLRHO.

rj

is the distance from the acoustic source grid j on the


panel to the microphone location grid (see Figure 1).

V flux f

is the velocity flux of the source grid j .

k is the wave number as defined in Wave Number.


i is the square root of -1
np is the number of source grids (see Figure 1).
q is the value of the scale factor specified using the
parameter PARAM, SPLFAC.

Altair Engineering

OptiStruct 13.0 Reference Guide 1667


Proprietary Information of Altair Engineering

PARAM, SPLREFDB
Parameter
SPLREFDB

Values

Description

Real > 0.0


Default = 1.0

This parameter can be used to specify the reference sound


pressure value used to calculate the Sound Pressure Level
(SPL) in decibels (dB).
Note:
The Sound Pressure Level (SPL) in decibels can be
calculated using the following equation:

SPLdB

20.0 * log10 (

SPL
SPLREFDB

Where,

SPLdB

is the Sound Pressure Level in decibels.

SPL

is the magnitude of the acoustic sound pressure


specified in the Radiated Sound Analysis section of the
Users Guide.

SPLREFDB is the reference sound pressure value specified


using this parameter.

1668 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SPLRHO
Parameter
SPLRHO

Values

Description

Real > 0.0


Default = 1.0

This parameter is used to specify the density of the


acoustic medium in the calculation of the complex acoustic
sound pressure and the complex particle velocity vector,
as shown below (see the Radiated Sound Analysis section
of the Users Guide for further information):
Sound Pressure Level
Total Complex Acoustic Sound Pressure requested by SPL
is:
np

ptotal f
j 1

f q
V flux f
rj

ie

ikr j

Where,

f is the frequency of the sound wave in the medium.


is the density of the acoustic medium defined by
PARAM, SPLRHO.

rj

is the distance from the acoustic source grid j on the


panel to the microphone location grid (see Figure 1).

V flux f

is the velocity flux of the source grid j .

k is the wave number as defined in Wave Number.


i is the square root of -1
np is the number of source grids (see Figure 1).
q is the value of the scale factor specified using the
parameter PARAM, SPLFAC.
Complex Particle Velocity Vector
The complex particle velocity vector is defined for each
frequency as follows:

uuur
( pv) j ( f )

pj ( f ) X
j
c

i
krj

Where,

pj ( f )

Altair Engineering

is the complex acoustic pressure due to source

OptiStruct 13.0 Reference Guide 1669


Proprietary Information of Altair Engineering

Parameter

Values

Description
grid j at the microphone location.

X
j

is the unit vector from the source grid j to the


microphone grid

r
Xj
r
Xj

X
j

r
Xj
rj

(see Figure 1)

is the density of the acoustic medium defined by


PARAM, SPLRHO.

c is the speed of sound defined by PARAM, SPLC.


k is the wave number defined above under Wave Number.

rj

is the distance from the acoustic source grid j on the


panel to the microphone grid (see Figure 1).

i is the square root of -1


Note:
1.

This parameter is used to specify the acoustic medium


density used in Radiated Sound Analysis. The same
value is used in the Equivalent Radiated Power (ERP)
calculations (See PARAM, ERPRHO).

2.

If both PARAM, SPLRHO and PARAM, ERPRHO are


specified in the same input deck, then the last
instance dominates.

1670 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, SRCOMPS
Parameter
SRCOMPS

Values

Description

<YES, NO>
Default = NO

If YES, the strength ratios are output for composite


elements that have failure indices requested. (The
Output formats currently supported are: H3D, HM, OP2,
PCH and OPT)
If NO or blank, the strength ratio will not be output.
Note:
The Strength Ratios that are output as a result of
PARAM, SRCOMPS, YES depend on the Failure Theory
specified by the user. The following equations show the
relationship between the Failure Index and the Strength
Ratio for different Failure Theories.
Hill Failure Theory:

Strength Ratio

1
Failure Index

Hoffman Failure Theory: There is no direct relationship


between the Strength Ratio and Failure Index. (refer to
the Composite Laminates section of the Users Guide for
more information).
Tsai-Wu Failure Theory: There is no direct relationship
between the Strength Ratio and Failure Index. (refer to
the Composite Laminates section of the Users Guide for
more information).
Maximum Stress (Strain) Failure Theory:

Strength Ratio

1
Failure Index

For the Transverse Shear Failure Theory:

Strength Ratio

Altair Engineering

1
Failure Index

OptiStruct 13.0 Reference Guide 1671


Proprietary Information of Altair Engineering

PARAM, SS2GCR
Parameter

Values

Description

SS2GCR

<REAL>
Default = 5.0

PARAM, SS2GCR is used to control the accuracy of the


AMLS solution.
Refer to the Users Guide section, Using the AMLS
(Automatic Multi-Level Sub-structuring) Eigensolver for
more details.

1672 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, STRTHR
Parameter

Values

Description

STRTHR
Default = 0.0

This parameter can be used to specify the von Mises


stress threshold above which the stress results are output
for a model.
Note
1.

PARAM, STRTHR applies to all static subcases defined


within a model. The stress results for a particular
element are not output ONLY if its von Mises stress
value falls below STRTHR for ALL static subcases.
For example, if the von Mises stress results for
elements ID=1 and ID=2 fall below the threshold for
subcase 1, but are above the threshold for subcase 2;
then the stress results for both elements (ID=1 and
ID=2) are output for both subcases.

Altair Engineering

2.

PARAM, STRTHR applies to stress results output in all


active formats.

3.

PARAM, STRTHR is supported for static analysis only.

4.

If PARAM, STRTHR is defined in a model, then 1D


element stresses are not output, regardless of their
stress level or the specified threshold.

OptiStruct 13.0 Reference Guide 1673


Proprietary Information of Altair Engineering

PARAM, THCNTPEN
Parameter
THCNTPEN

Values

Description

AUTO, LOW,
HIGH
Default = AUTO

PARAM, THCNTPEN controls the penalty factor used in


thermal contact analysis.
AUTO:
Determines the value of conductivity for each contact/
gap element based on the conductivity of surrounding
elements.
LOW:
Imposes a lower penalty factor that reduces the
conductivity of each contact/gap element compared to
the conductivities of the surrounding elements. It can be
used when the program runs into convergence
difficulties.
HIGH:
Imposes a higher penalty factor that increases the
conductivity of each contact/gap element compared to
the conductivities of the surrounding elements. It can be
used to enforce stronger conduction.
Note:
1.

Theoretically, while higher conductivity values


enforce a perfect conductor, excessively high values
may result in poor conditioning of the conductivity
matrix. In such cases, it may be beneficial to reduce
the value of conductivity, or use conductivity based
contact clearance and pressure.

2.

This parameter influences the KC field of the


PCONTHT bulk data entry and the KAHT field of the
PGAPHT bulk data entry.

1674 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, TOLRSC
Parameter
TOLRSC

Values

Description

Real
Default = 0.05

When the RSSCON shell-to-solid element connector is


used, the connecting grid points of the shell element
are moved onto the solid face if the grid points are
close enough. The tolerable distance of the shell grid
point to the solid edge or face is
where h is the
height of the solid edge. Rigid body invariance is
satisfied with double-precision accuracy if the shell grid
points are adjusted.

Altair Engineering

OptiStruct 13.0 Reference Guide 1675


Proprietary Information of Altair Engineering

PARAM, TRAKMETH
Parameter

Values

Description

TRAKMETH

<0, 1, 2>

TRAKMETH is a parameter that can be used to select


the criterion employed for mode tracking.

Default = 0
Defaults:
-The value of
this parameter is
0 if it is not
included in input
file.
-If this parameter
is included in the
input file, but no
value is provided,
then running the
program will
result in an error.

There are three tracking criteria available for selection


in the current implementation:
Mass cross-orthogonality check (CORC)
Modal assurance criterion (MAC)
Modal assurance criterion square root (MACSR).
If TRAKMETH = 0
The Mass cross-orthogonality check (CORC) criterion is
used for mode tracking. This performs a mass
orthogonality check of the current and previous
eigenvectors after reanalysis. CORC is implemented as
follows:

If TRAKMETH = 1
The Modal assurance criterion square root (MACSR)
criterion is used for mode tracking. This criterion
essentially calculates the dot product of the two unit
vectors associated with the current and previous
eigenvectors. MACSR is implemented as follows:

If TRAKMETH = 2
The standard modal assurance criterion (MAC) is used
for mode tracking. MAC is implemented as follows:

Where,
is the current eigenvector.
is the previous eigenvector.
is the mass matrix.

1676 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, TRAKMTX
Parameter

Values

Description

TRAKMTX

<0, 1>
Default = 0

TRAKMTX is a parameter that controls the output of the


mode tracking matrix during optimization.

If TRAKMTX = 1
The mode tracking matrix will be printed to the output file
-The value of this at each iteration.
parameter is 0 if
If TRAKMTX = 0
it is not included
The mode tracking matrix will not be printed to the
in input file.
output file.
-If this parameter
is included in the Note:
input file, but no
Each element of the mode tracking matrix stores the
value is provided, correlation value of two eigenvectors which is calculated
then running the
using certain mode tracking criteria (see PARAM,
program will result TRAKMETH).
Defaults:

in an error.

Example
The following is an example of the mode tracking matrix.
For this example, assume that:
1.

The first 5 modes are being tracked.

2.

10 modes are calculated for each analysis

3.

PARAM, MFILTER is set to 0.7.

Mode Tracking Matrix

Based on the above matrix, mode 1 (of the previous


iteration) will get tracked to mode 1 (of current
iteration). Mode 2 will get tracked to mode 2. Mode 3 will
get tracked to mode 4. Mode 4 will get tracked to mode
3. And mode 5 could not be tracked to any of the 10
modes in the current iteration (out of bounds).

Altair Engineering

OptiStruct 13.0 Reference Guide 1677


Proprietary Information of Altair Engineering

PARAM, TPS
Parameter

Values

Description

TPS

<YES, NO>
Default = YES

PARAM, TPS may be used with transient response


analysis. When only shell stress results are required from
a transient response analysis, significant speed
improvements in run time can be obtained with the use of
this parameter.
YES: fast transient response analysis is activated only
shell stress results output may be requested in this case.
that is, no displacement results are output.
NO: normal transient response analysis is performed.

1678 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, UCORD
Parameter
UCORD

Values

Description

<CID>

If = -1, the mass moment of inertia is calculated about the


center of gravity and is output in the basic coordinate
system.

Default = -1

If = 0, the mass moment of inertia is calculated about the


origin of the basic coordinate system. The output values
are expressed in the basic coordinate system.
the center of gravity coordinates are expressed in
the coordinate system CID. The mass moment of inertia is
calculated about the center of gravity and expressed in
the coordinate system CID.
Note:

Altair Engineering

1.

If PARAM, UCORD is not specified, CID = -1, or CID


given is not found, all values in PARAM, GRDPNT are
calculated relative to the basic coordinate system.

2.

If PARAM, GRDPNT is not specified in the input deck,


then the center of gravity and moment of inertia are
not output regardless of the value of PARAM, UCORD.

OptiStruct 13.0 Reference Guide 1679


Proprietary Information of Altair Engineering

PARAM, VMOPT
Parameter
VMOPT

Values

Description

<Integer = 0, 1,
2>
Default = 0

If PARAM,VMOPT is set to 0 or 1, then the virtual mass


of the fluid is included in the mass matrix for all
calculations. This can increase the calculation time
because of the dense mass matrix on the damp surface
of the structure.
If PARAM,VMOPT,2 is specified, the eigenvalue solution
is performed without adding the mass contribution from
MFLUID, so that dry modes are calculated. A second
eigenvalue analysis is performed to get the damp modes,
which are used in modal dynamic solution. This solution
is much faster with only a slight loss of accuracy.
Note: Dry mode output in the .out file is available only
when PARAM,VMOPT,2 is specified.

1680 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, W3
Parameter

Values

Description

W3

<Real>
Default = 0.0

Used in transient analyses to convert structural damping to


equivalent viscous damping.
The damping matrix [B] for transient analysis is assembled
from:

where:
is the contribution from damping elements (CDAMP#,
CVSIC) and B2GG.
is the overall structural damping coefficient (PARAM,
G).
is the frequency of interest in radians per unit time
(PARAM, W3) for the conversion of overall structural
damping into equivalent viscous damping.

[K]

is the global stiffness matrix.


is the element structural damping coefficient (GE on
the MAT# entry).
is the frequency of interest in radians per unit time
(PARAM, W4) for the conversion of element structural
damping into equivalent viscous damping.
is the element stiffness matrix.

Altair Engineering

OptiStruct 13.0 Reference Guide 1681


Proprietary Information of Altair Engineering

PARAM, W4
Parameter

Values

Description

W4

<Real>
Default = 0.0

Used in transient analyses to convert structural damping to


equivalent viscous damping.
The damping matrix [B] for transient analysis is assembled
from:

where:
is the contribution from damping elements (CDAMP#,
CVSIC) and B2GG.
is the overall structural damping coefficient (PARAM,
G).
is the frequency of interest in radians per unit time
(PARAM, W3) for the conversion of overall structural
damping into equivalent viscous damping.

[K]

is the global stiffness matrix.


is the element structural damping coefficient (GE on
the MAT# entry).
is the frequency of interest in radians per unit time
(PARAM, W4) for the conversion of element structural
damping into equivalent viscous damping.
is the element stiffness matrix.

1682 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, WR3
Parameter
WR3

Values

Description

<Real>
Default = 0.0

This parameter is used to include or exclude frequency


dependent damping in rotor dynamics analysis.
PARAM, WR3, <Real>
If any real value except 0.0 (default) is specified, then it
is included in the rotor dynamics equation as the
average excitation frequency. PARAM, WR3, <Real>
should be specified to activate frequency dependent
damping if PARAM, GYROAVG is set to -1.
PARAM, WR3, 0
If 0.0 is specified, then frequency dependent damping
terms are not included in rotor dynamics analysis.
Refer to the Users Guide section, Rotor Dynamics for more
details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1683


Proprietary Information of Altair Engineering

PARAM, WR4
Parameter
WR4

Values

Description

<Real>
Default = 0.0

This parameter is used to include or exclude frequency


dependent damping in rotor dynamics analysis.
PARAM, WR4, <Real>
If any real value except 0.0 (default) is specified, then it
is included in the rotor dynamics equation as the
average excitation frequency. PARAM, WR4, <Real>
should be specified to activate frequency dependent
damping if PARAM, GYROAVG is set to -1.
PARAM, WR4, 0
If 0.0 is specified, then frequency dependent damping
terms are not included in rotor dynamics analysis.
Refer to the Users Guide section, Rotor Dynamics for more
details.

1684 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, WTMASS
Parameter

Values

Description

WTMASS

Real > 0.0


Default = 1.0

The WTMASS (Weight-To-MASS) parameter is used as a


multiplier for the terms of the structural mass matrix.
Note
PARAM, WTMASS cannot be applied to superelements
(.h3d or .pch) that are read into the model. If the unit of
mass is incorrect on the MAT# entries and PARAM,
WTMASS is required to update the structural mass
matrix; then this should be done in the creation run.

Altair Engineering

OptiStruct 13.0 Reference Guide 1685


Proprietary Information of Altair Engineering

PAXI
Bulk Data Entry
PAXI Axisymmetric Element Property
Description
Defines the properties of axisymmetric elements. Referenced by CTAXI entry.
Format
(1)

(2)

(3)

(4)

PAXI

PID

MID

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

PAXI

203

(4)

(5)

(6)

(7)

(8)

(9)

Field

Contents

PID

Unique axisymmetric element property identification number.

(10)

No default (Integer > 0)


MID

Identification number of a MAT1 or MAT3 entry.


No default (Integer > 0)

Comments
1.

All axisymmetric element property entries must have unique ID numbers.

2.

This card is represented as a property in HyperMesh.

1686 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PBAR
Bulk Data Entry
PBAR Simple Beam Property
Description
The PBAR bulk data entry defines the properties of a simple beam (bar), which is used to
create bar elements via the CBAR entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PBAR

PID

MID

I1

I2

NSM

C1

C2

D1

D2

E1

E2

F1

K1

K2

I12

(9)

(10)

F2

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

PBAR

39

2.9

8.4

5.97

1.1

2.0

4.0

Field

Contents

PID

Unique simple beam property identification number.

(8)

(9)

(10)

No default (Integer > 0)


MID

Material identification number. See comment 1.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1687


Proprietary Information of Altair Engineering

Field

Contents

Area of bar cross-section.


No default (Real > 0.0)

I1

Area moment inertia in plane 1 about the neutral axis.


No default (Real > 0.0)

I2

Area moment inertia in plane 2 about the neutral axis.


No default (Real > 0.0)

I12

Area product of inertia.


Default = 0.0 (Real) (

Torsional constant.
Default = 0.0 (Real > 0.0)

NSM

Nonstructural mass per unit length.


Default = 0.0 (Real)

K1, K2

Area factor for shear.


Default = 0.0 (Real)

Ci, Di,
Ei, Fi

Stress recovery coefficients.


Default = 0.0 (Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

2.

The transverse shear stiffness in planes 1 and 2 are (K1)AG and (K2)AG, respectively.
The default values for K1 and K2 are infinite; in other words, the transverse shear
used for K1 and K2, the transverse shear flexibilities are set to 0.0 (K1 and K2 are
interpreted as infinite).

1688 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

The stress recovery coefficients C1 and C2, and so on, are the y and z coordinates in the
BAR element coordinate system of a point at which stresses are computed. Stresses are
computed at both ends of the BAR.

Fig 1: C oordinate System for Bar Element (PBAR).

4.

The moments of inertia are defined as follows:

5.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1689


Proprietary Information of Altair Engineering

PBARL
Bulk Data Entry
PBARL Simple Beam Property
Description
Defines the properties of a simple beam (bar) by cross-sectional dimensions, which is used to
create bar elements via the CBAR entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PBARL

PID

MID

GROUP

TYPE/
NAME

ND

DIM1

DIM2

DIM3

DIM4

DIM5

DIM9

NSM

(7)

(8)

(9)

(10)

DIM6

DIM7

DIM8

Example

(1)

(2)

(3)

PBARL

12

10.

6.

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BOX

.5

.5

Field

Contents

PID

Unique simple beam property identification number.


No default (Integer > 0)

MID

Material identification number. See comment 1.


No default (Integer > 0)

1690 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

GROUP

Indicates if an arbitrary beam section definition is to be used. Refer to


Arbitrary Beam Section Definition in the Users Guide. If the value of this field is
HYPRBEAM, the following field is NAME; otherwise it is TYPE.
Default = blank (blank or HYPRBEAM)

TYPE

Cross-section type. When GROUP field is blank, this field is TYPE.


No default ("BAR", "BOX", "BOX1", "CHAN", "CHAN1", "CHAN2", "CROSS", "H",
"HAT", "I", "I1", "ROD", "T", "T1", "T2", "TUBE", "Z")

NAME

Name of arbitrary beam section definition. Refer to Arbitrary Beam Section


Definition in the Users Guide. When the value of GROUP is HYPRBEAM, this field
is NAME.
No default (Character string)

ND

Number of dimensions used to specify the Cross-section shape. This is required


when the value of the GROUP field is HYPRBEAM. ND represents the total number
of dimensions used to define an Arbitrary Beam Section.
Default = blank

DIMi

Cross-sectional dimensions.
No default (Real > 0.0)

NSM

Nonstructural mass per unit length. NSM is specified after the last DIMi.
Default 0.0 (Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

2.

The cross-sectional properties, shear flexibility factors, and stress recovery points (C, D,
E, and F) are computed using the TYPE and DIMi as shown below. The origin of the
element coordinate system is centered at the shear center of the cross-section oriented
as shown. The PBARL does not account for offsets between the neutral axis and the
shear center. Therefore, the CHAN cross-sections may produce incorrect results. The
PBEAML entry is recommended.

Altair Engineering

OptiStruct 13.0 Reference Guide 1691


Proprietary Information of Altair Engineering

Type = BAR

Type = BOX

Type = BOX1

Type = CHAN

1692 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type = CHAN1

Type = CHAN2

Type = CROSS

Type = H

Altair Engineering

OptiStruct 13.0 Reference Guide 1693


Proprietary Information of Altair Engineering

Type = HAT

Type = I

Type = I1

Type = ROD

1694 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type = T

Type = T2

Altair Engineering

Type = T1

Type = TUBE

OptiStruct 13.0 Reference Guide 1695


Proprietary Information of Altair Engineering

Type = Z
3.

This card is represented as a property in HyperMesh.

1696 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PBARX
Bulk Data Entry
PBARX Optional BAR Property Extension for Geometric Nonlinear Analysis
Description
Defines additional BAR properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PBARX

PID

ISMSTR

ISTRAIN

DM

DB

(7)

(8)

(9)

(10)

Field

Contents

PID

Property identification number of the associated PBAR or PBARL card. See


comment 1.
No default (Integer > 0)

ISMSTR

Flag for small strain formulation.


Default = 2 (Integer = 1, 2)
1 - Small strain from time =0
2 - Full geometric nonlinearity

ISTRAIN

Flag for shear in beam formulation.


Default = ON (ON or OFF)

DM

Beam membrane damping.


Default = 0.0 (Real > 0)

DB

Beam bending damping.


Default = 0.01 (Real > 0)

Comments
1.

The property identification number must be that of an existing PBAR bulk data entry. Only
one PBARX property extension can be associated with a particular PBAR.

Altair Engineering

OptiStruct 13.0 Reference Guide 1697


Proprietary Information of Altair Engineering

2.

PBARX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

If the small strain option is activated (ISMSTR = 1), the strain and stress are engineering
strain and stress; otherwise they are true strain and stress.

4.

This card is represented as an extension to a PBAR property in HyperMesh.

1698 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PBEAM
Bulk Data Entry
PBEAM Beam Property
Description
The PBEAM bulk data entry defines the properties of beam elements defined via the CBEAM
entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PBEAM

PID

MID

A(A)

I1(A)

I2(A)

I12(A)

J(A)

NSM(A)

C 1(A)

C 2(A)

D1(A)

D2(A)

E1(A)

E2(A)

F1(A)

F2(A)

(10)

The following two continuation lines may be repeated up to ten times. They are used to
define stations along the beam element.
SO

X/XB

I1

I2

I12

NSM

C1

C2

D1

D2

E1

E2

F1

F2

NSIA

NSIB

N1A

N2A

N1B

N2B

The last two continuation lines are:


K1

K2

M1A

M2A

Altair Engineering

M1B

M2B

OptiStruct 13.0 Reference Guide 1699


Proprietary Information of Altair Engineering

Fig 1: Beam Element C oordinate System (for PBEAM entry)

Example 1

This example represents a straight beam with stress recovery, only at end A.
(1)

(2)

(3)

(4)

(5)

(6)

PBEAM

9.5

18.073

98.792

0.0

2.0

0.0

-2.0

NO

1.0

(7)

(8)

(9)

(10)

0.813

2.1

0.5

Example 2

This example represents a tapered beam with an intermediate section defined halfway
along its length and stress recovery at both end A and end B.

1700 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Note that the blank line after YES is entered for Stress Output (SO) at end B.
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PBEAM

9.5

18.073

98.792

0.813

0.0

2.0

0.0

-2.0

NO

0.5

6.5

5.385

35.542

0.563

YES

1.0

3.5

0.698

7.292

0.313

(9)

(10)

2.1

0.5

Field

Contents

PID

Property identification number.


No default (Integer > 0)

MID

Material identification number. See comment 1.


No default (Integer > 0)

A(A)

Area of beam cross-section at end A.


No default (Real > 0.0)

I1(A)

Area moment inertia in plane 1 about the neutral axis at end A.


No default (Real > 0.0)

I2(A)

Area moment inertia in plane 2 about the neutral axis at end A.


No default (Real > 0.0)

I12(A)

Area product inertia at end A (

).

Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1701


Proprietary Information of Altair Engineering

Field

Contents

J(A)

Torsional stiffness parameter at end A.


Default = 0.0 (Real > 0.0)

NSM(A)

Nonstructural mass per unit length at end A.


Default = 0.0 (Real)

Ci(A), Di(A),
Ei(A), Fi(A)

The y and z locations in element coordinates for stress data recovery at


end A. (i=1 is y and i=2 is z)
Default = 0.0 for all entries (Real)

SO

Stress output request option for intermediate stations and end B. See
comments 5 through 8.
If set to NO, the following continuation line (containing fields C1 through
F2) must be omitted for that intermediate station, and no stresses are
recovered for that intermediate station.
If set to YESA, the following continuation line (containing fields C1
through F2) must be omitted for that intermediate station, and stresses,
for that intermediate station, are recovered at the stress recovery
locations identified for end A.
If set to YES, the following continuation line (containing fields C1 through
F2) must contain the same stress recovery locations as the first
continuation line (containing fields C1(A) through F2(A)) or must be
entirely blank.
Default = YES (YES, YESA, or NO)

X/XB

Fractional distance of the intermediate station from end A.


Default = 1.0 (Real > 0.0)

Area of beam cross-section for intermediate stations.


Default = A(A) (Real > 0.0)

I1

Area moment inertia in plane 1 about the neutral axis for intermediate
stations.
Default = I1(A) (Real > 0.0)

1702 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

I2

Area moment inertia in plane 2 about the neutral axis for intermediate
stations.
Default = I2(A) (Real > 0.0)

I12

Area product inertia for intermediate stations (

).

Default = I12(A) (Real)


J

Torsional stiffness parameter for intermediate stations.


Default = J(A) (Real > 0.0)

NSM

Nonstructural mass per unit length for intermediate stations.


Default = NSM(A) (Real)

Ci, Di, Ei, Fi

The y and z locations in element coordinates for stress data recovery for
intermediate stations. (i=1 is y and i=2 is z). See comments 5 through 8.
Default = 0.0 for all entries. (Real)

K1,K2

Shear stiffness factor K in K*A*G for plane 1 and plane 2.


Default = 1.0 for both (Real)

NSIA

Nonstructural mass moment of inertia per unit length about nonstructural


mass center of gravity at end A.
Default = 0.0 (Real)

NSIB

Nonstructural mass moment of inertia per unit length about nonstructural


mass center of gravity at end B.
Default = NSIA (Real)

M1A, M2A

(y,z) coordinates of center of gravity of nonstructural mass at end A.


Default = 0.0, 0.0 (Real)

M1B, M2B

(y,z) coordinates of center of gravity of nonstructural mass at end B.


Default = M1A, M2A (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1703


Proprietary Information of Altair Engineering

Field

Contents

N1A, N2A

(y,z) coordinates of neutral axis at end A.


Default = 0.0, 0.0 (Real)

N1B, N2B

(y,z) coordinates of neutral axis at end B.


Default = N1A, N2A (Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

2.

Blank fields for K1 and K2 are defaulted to 1.0. If a value of 0.0 is used for K1 and K2,
the transverse shear flexibilities are set to 0.0.

3.

One value for X/XB must be 1.0.

4.

The moments of inertia are defined as follows:

5.

Stress recovery is only allowed at end A and end B. Stress recovery at intermediate
stations is not supported.

6.

If no stress data at end A is to be recovered, but a stress recovery location is defined for
end B, then the first continuation entry, which contains the fields C1(A) through F2(A),
may be omitted.

7.

If the continuation line containing values C1 through F2 is entirely blank for end B, then
the stress recovery locations defined for end A are used. However, if any entry is defined
on this line, then all blank entries will default to 0.0 and not the corresponding entry for
end A.

8.

Stress recovery locations must be the same for end A and end B.

9.

OSDIAG, 166, 1 may be input in the I/O options section of the input deck to bypass error
terminations caused by PBEAM definitions which violate the rules outlined in comments 5
and 8. In such instances, the following occurs:
Warning messages regarding the violations are echoed to the .out file.
Stress is not recovered at intermediate stations.
Recovery locations defined for end A are also used for end B.

10. For tapered beams, a single prismatic beam is created with properties obtained by
weighted averaging of all station properties.

1704 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

11. The cross-sectional properties have to be specified fully for end A. For end B, blank fields
mean that the properties are the same as for end A. For intermediate stations, blank
fields result in a linear interpolation between the property value at end A and end B being
used.
12. The NSM specified at end A is the default value for NSM at end B. The default for all
other stations is a linear interpolation between end A and end B. So, for a constant NSM
over the length of the beam, only NSM at end A is required.
The mass of the element is calculated as:
Mass = density * beam_area * beam_length + NSM * beam_length
If the NSM value is different in different stations, it is averaged over all the stations and
the average is used in the element calculation.
13. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1705


Proprietary Information of Altair Engineering

PBEAML
Bulk Data Entry
PBEAML Beam Property
Description
Defines the properties of a beam element by cross-sectional dimensions that are used to
create beam elements via the CBEAM entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PBEAML

PID

MID

GROUP

TYPE/
NAME

ND

DIM1(A)

DIM2(A)

NSM(A)

NSM(1)

SO(B)

(10)

SO(1)

X(1)/XB

DIM1(1)

DIM2(1)

X(B)/XB

DIM1(B)

DIM2(B)

NSM(B)

* The format of this bulk data


entry is somewhat unusual as
the field locations can vary
depending on the number of
dimensions used to define the
cross-section.

Example

(1)

(2)

(3)

(4)

PBEAML

99

21

12.

14.8

2.5

7.

1.2

2.6

5.6.

2.3

(5)

(6)

(7)

(8)

(9)

NO

0.4

6.

0.6

6.

7.8

(10)

26.

YES

YES

1706 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

PID

Property identification number.


No default (Integer > 0)

MID

Material identification number. See comment 1.


No default (Integer > 0)

GROUP

Indicates if an arbitrary beam section definition is to be used. Refer to


Arbitrary Beam Section Definition in the Users Guide. If the value of
this field is HYPRBEAM, the following field is NAME; otherwise it is TYPE.
Default = blank (blank or HYPRBEAM)

TYPE

Cross-section shape. When GROUP field is blank, this field is TYPE.


No default ("BAR", "BOX", "BOX1", "CHAN", "CHAN1", "CHAN2", "CROSS",
"H", "HAT", "I", "I1", "L", "ROD", "T", "T1", "T2", "TUBE", "Z")

NAME

Name of arbitrary beam section definition. Refer to Arbitrary Beam


Section Definition in the Users Guide. When the value of GROUP is
HYPRBEAM, this field is NAME.
No default (Character string)

ND

Number of dimensions used to specify the Cross-section shape. This is


required when the value of the GROUP field is HYPRBEAM. ND represents
the total number of dimensions used to define an Arbitrary Beam
Section.
Default = blank

DIMi(A)

Cross-section dimensions at end A.


No default (Real > 0.0)

NSM(A)

Nonstructural mass per unit length at end A.


Default = 0.0 (Real)

SO(#)

Stress output request option for intermediate station #.


Stress output is not supported for intermediate stations so this field
must be set to NO.

X(#)/XB

Distance from end A to intermediate station # in the element coordinate

Altair Engineering

OptiStruct 13.0 Reference Guide 1707


Proprietary Information of Altair Engineering

Field

Contents
system, divided by the length of the element.
Default = 1.0 (Real > 0.0)

DIMi(#)

Cross-section dimensions at intermediate station #.


(Real > 0.0)

NSM(#)

Nonstructural mass per unit length at intermediate station #.


Default = 0.0 (Real)

SO(B)

Stress output request option for end B.


Default = YES (YES or NO)

X(B)/XB

Distance form end A to end B in the element coordinate system, divided


by the length of the element.
This must be 1.0

DIMi(B)

Cross-section dimensions at end B


(Real > 0.0)

NSM(B)

Nonstructural mass per unit length at end B.


Default = 0.0 (Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

2.

Up to eleven stations are allowed (end A and B, and nine intermediate stations #).

3.

The cross-sectional properties, shear flexibility factors, and stress recovery points (C, D,
E, and F) are computed using the TYPE and DIMi as shown below. The element
coordinate system is located at the shear center.

1708 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type = BAR

Type = BOX

Type = BOX1

Type = CHAN

Altair Engineering

OptiStruct 13.0 Reference Guide 1709


Proprietary Information of Altair Engineering

Type = CHAN1

Type = CHAN2

Type = CROSS

Type = H

1710 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type = HAT

Type = I

Type = I1

Type = L

Altair Engineering

OptiStruct 13.0 Reference Guide 1711


Proprietary Information of Altair Engineering

Type = ROD

Type = T

Type = T1

Type = T2

1712 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type = TUBE

Type = Z

4.

For PBEAML entries with more than one section, an equivalent PBEAM entry is derived. An
echo request will cause a printout of the derived PBEAM.

5.

Stress recovery is only allowed at end A and end B. Stress recovery at intermediate
stations is not supported.

6.

For tapered beams, a single prismatic beam is created with dimensions obtained by
weighted averaging of all station dimensions.

7.

DIMi and NSM have to be specified fully on station A. On station B, blank means that the
dimensions are the same as at A. On other stations, it is a linear interpolation between A
and B.

8.

The NSM specified at end A is the default value for NSM at end B. The default for all
other stations is a linear interpolation between end A and end B. So, for a constant NSM
over the length of the beam, only NSM at end A is required.
The mass of the element is calculated as:
Mass = density * beam_area * beam_length + NSM * beam_length
If the NSM value is different in different stations, it is averaged over all the stations and
the average is used in the element calculation.

9.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1713


Proprietary Information of Altair Engineering

PBEAMX
Bulk Data Entry
PBEAMX Optional BEAM Property Extension for Geometric Nonlinear Analysis
Description
Defines additional BEAM properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PBEAMX

PID

ISMSTR

ISTRAIN

DM

DB

(7)

(8)

(9)

(10)

Field

Contents

PID

Property identification number of the associated PBEAM, PBEAML. See


comment 1.
No default (Integer > 0)

ISMSTR

Flag for small strain formulation.


Default = 2 (Integer = 1, 2)
1 - Small strain from time =0
2 - Full geometric non-linearity

ISTRAIN

Flag for shear in beam formulation.


Default = ON (ON or OFF)

DM

Beam membrane damping.


Default = 0.0 (Real > 0.0)

DB

Beam bending damping.


Default = 0.01 (Real > 0.0)

Comments
1.

The property identification number must be that of an existing PBEAM bulk data entry.
Only one PBEAMX property extension can be associated with a particular PBEAM.

1714 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

PBEAMX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

If the small strain option is activated (ISMSTR = 1), the strain and stress are engineering
strain and stress; otherwise they are true strain and stress.

4.

This card is represented as an extension to a PSOLID property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1715


Proprietary Information of Altair Engineering

PBUSH
Bulk Data Entry
PBUSH Generalized Spring-Damper-Mass Property
Description
Defines the nominal property values for a generalized spring-damper-mass structural element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PBUSH

PID

K1

K2

K3

K4

K5

K6

B1

B2

B3

B4

B5

B6

GE

GE1

GE2

GE3

GE4

GE5

GE6

M1

M2

M3

M4

M5

M6

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

PBUSH

35

4.35

2.4

RIGID

GE

0.02

(5)

(6)

(7)

(8)

(9)

(10)

3.1

Example 2

(1)

(2)

(3)

(4)

PBUSH

35

4.35

1.2

(7)

(8)

(9)

(10)

7.1

1716 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

PID

Property identification number.


No default (Integer > 0)

Flag indicating that the next 1 to 6 fields are stiffness values.


No default (Character)

Ki

Nominal stiffness values in directions 1 through 6. See comments 3, 6, and


8.
Default = 0.0 (Real or RIGID)

Flag indicating that the next 1 to 6 fields are force-per-velocity damping.


No default (Character)

Bi

Nominal damping coefficients in directions 1 through 6 in units of force per


unit velocity.
Default = 0.0 (Real)

GE

Flag indicating that the next 1 to 6 fields are the structural damping
constants.
No default (Character)

GEi

Nominal structural damping constants in directions 1 through 6. See


comments 3, 5, and 6.
Default = 0.0 (Real)

Flag indicating that the next 1 to 6 fields are directional masses.

Mi

Nominal mass values in directions 1 through 6. See comment 7.


Default = 0.0 (Real)

Comments
1.

All generalized spring-damper-mass property entries must have unique ID numbers.

2.

The K, B, GE, and M lines may be specified in any order.

Altair Engineering

OptiStruct 13.0 Reference Guide 1717


Proprietary Information of Altair Engineering

3.

Ki, Bi, GEi, or Mi may be made frequency dependent for both direct and modal frequency
response by use of the PBUSHT entry.
The nominal values are used for all analysis types except frequency response. For modal
frequency response, the normal modes are computed using the nominal Ki values. The
frequency-dependent values are used at every excitation frequency.

4.

To obtain the damping coefficient GE, multiply the critical damping ratio C/C0 by 2.0.

5.

If PARAM, W4 is not specified, GEi is ignored in transient analysis.

6.

For upward compatibility, if ONLY GE1 is specified on a PBUSH entry and GEi, i = 2 to 6 are
blank on that PBUSH entry, then a single structural damping is assumed and applied to all
Ki of that PBUSH. If a PBUSH entry has a GEi, i = 2 to 6 specified, then the GEi fields are
considered variable for that PBUSH entry.

7.

The Mi fields do not contribute to mass and inertia properties. Their contributions to
gravity and/or centrifugal loading are also not included.

8.

The keyword RIGID may be used in place of a stiffness value for Ki entries. When RIGID is
defined, a very high relative stiffness (relative to the surrounding structure) is selected
for that degree-of-freedom simulating a rigid connection.

9.

This card is represented as a property in HyperMesh.

1718 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PBUSH1D
Bulk Data Entry
PBUSH1D Rod-type Spring-and-Damper Property
Description
Defines the linear and nonlinear properties for a one-dimensional spring-and-damper structural
element.
Format
(1)

(2)

(3)

(4)

(5)

PBUSH1D

PID

SPRING

TYPE

IDT

(6)

(7)

(8)

(9)

(10)

Example 1

(1)

(2)

(3)

(4)

PBUSH1D

35

4.35

0.5

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example 2

(1)

(2)

(3)

PBUSH1D

35

4.35

SPRING

TABLE

(5)

(6)

(7)

(8)

(9)

(10)

43

Field

Contents

PID

Property identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1719


Proprietary Information of Altair Engineering

Field

Contents

Stiffness.
Default = 0.0 (Real > 0)

Viscous damping.
Default = 0.0 (Real > 0)

Total mass.
Default = 0.0 (Real > 0)

SPRING String indicating that a function defining the spring characteristics follows.
TYPE

Type of input definition.


Default = TABLE (Character = TABLE)

IDT

Identification number of a TABLEDi table entry.


No default (Integer > 0)

Comments
1.

Either the stiffness K, or the damping B, or the mass M must be specified. B and M are
ignored in static subcases.

2.

The SPRING continuation line is used in nonlinear analysis solution sequences only. The
table input supersedes the stiffness K.

3.

PBUSH1D may only be referenced by CBUSH1D elements.

4.

In all linear subcases, as well as small displacement nonlinear quasi-static


(ANALYSIS=NLSTAT) subcases, PBUSH1D and CBUSH1D are converted internally to the
equivalent PBUSH (with PBUSHT, if necessary) and CBUSH.

5.

This card is represented as a property in HyperMesh.

1720 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PBUSHT
Bulk Data Entry
PBUSHT Generalized Spring and Damper Property
Description
Defines property values for a generalized spring and damper structural element.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PBUSHT

PID

TYPE

TID1

TID2

TID3

TID4

TID5

TID6

TYPE

TID1

TID2

TID3

TID4

TID5

TID6

TYPE

TID1

TID2

TID3

TID4

TID5

TID6

TYPE

TID1

TID2

...

...

Field

Contents

PID

Property identification number. Must match with a PID of a PBUSH Bulk


Data Entry.

(10)

No default (Integer > 0)


TYPE

Identifies what the following six fields reference.


If TYPE is K, then the following six fields are stiffness vs. frequency table
references for dofs 1 through 6, respectively.
If TYPE is B, then the following six fields are viscous damping vs. frequency
table references for dofs 1 through 6, respectively.
If TYPE is GE, then the following six fields are structural damping vs.
frequency table references for dofs 1 through 6, respectively.

Altair Engineering

OptiStruct 13.0 Reference Guide 1721


Proprietary Information of Altair Engineering

Field

Contents
If TYPE is M, then the following six fields are directional mass vs. frequency
table references for dofs 1 through 6, respectively.
If TYPE is KN, then the following six fields are force vs. deflection table
references for dofs 1 through 6, respectively.
See comment 4.
No default (K, B, GE, M, or KN)

TID#

Identification number of a TABLED# entry. The type of the referenced


table is defined by the TYPE keyword given on the same line. The six
references on each line represent the 6 degrees-of-freedom in sequence
from 1 through 6.
Default = 0 (Integer > 0)

Comments
1.

The K, B, GE, and M fields are associated with the same entries on the PBUSH entry

2.

PBUSHT may only be referenced by CBUSH elements in the residual structure which do not
attach to any omitted degrees-of-freedom.

3.

The TYPEs can be defined in any order, but may only appear once per PBUSH definition.

4.

TYPE=K, B, GE and M are allowed for frequency response analysis only, while TYPE=KN is
allowed only for nonlinear analysis.

5.

For upward computability, if ONLY the dof1 field for the GE line (line where TYPE=GE) is
specified on ALL PBUSHT entries and the other dofs for the GE line are blank on ALL
PBUSH entries, then a single structural damping table for each PBUSHT applied to all
defined dofs on the K line for each PBUSH is assumed. If ANY PBUSHT entry has a dof
field other than dof1 for the GE line specified, then the GE fields are considered variable
on ALL PBUSH and PBUSHT entries.

6.

This card is represented as a property in HyperMesh.

1722 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCNTX2
Bulk Data Entry
PCNTX2 Extended CONTACT Property type 2 for Geometric Nonlinear Analysis
Description
Defines properties TYPE2 tied CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

PC NTX2

PID

IGNROE

(3)

(4)

(5)

(6)

FSPOT

LEVEL

ISRC H

IDELG

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

MAXND

MAXTD

(8)

(9)

If FSPOT = 20, 21, or 22, two continuation lines


(1)

(2)

(3)

(4)

(5)

(6)

RUPT

IFILT

SRTID

SNTID

STTID

FSTR

FSTRATE

FDIST

ALPHA

If FSPOT = 25, one continuation line


(1)

(2)

(3)

(4)

STFAC

VISC

(5)

(6)

(7)

(10)

Example

(1)

(2)

PC ONT

34

PC NTX2

34

Altair Engineering

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 1723


Proprietary Information of Altair Engineering

Field

Contents

PID

Property identification number of the associated PCONT.


No default (Integer > 0)

IGNORE

Flag to ignore slave nodes if no master segment found for TIE contact
(See comment 7).
Default as defined by CONTPRM (Integer = 0, 1, or 2)
0 - No deletion of slave nodes;
1 - Slave nodes with no master segment found are deleted from the
interface;
2 - Slave nodes with no master segment found are deleted from the
interface, if SRCHDIS is blank, then it would be new calculated internally.

FSPOT

Flag for spotweld formulation. (Integer).


Default = 5.
1 - Formulation is optimized for spotweld or rivets.
2 - Same formulation as standard formulation. Required when using
hierarchy levels. Not compatible with nodal time step (TSTYP= GRID, TSC
= CST).
4 - Rotational degrees of freedom are not transmitted (if shells are
used).
5 - Standard formulation.
20, 21, 22 - formulation with failure. Not compatible with nodal time step
GRID(CST) on XSTEP card. The stress is computed for each slave node
according to the "equivalent" surface around the node. The equivalent
surface is defined accordingly:
20 - Surface computed using shell and brick faces attached to the node.
21 - Surface computed using only the shell attached to the node.
22 - Surface computed using only the brick faces attached to the node.
25 - Penalty formulation.
30 - Formulation with cubic curvature of master segment. Not compatible
with nodal time step GRID(CST) on XSTEP card.

LEVEL

Hierarchy level of the interface.


No default (Integer > 0)

ISRCH

Search formulation flag for the closest master segment.


Default = 2 (Integer)
1 - Old formulation (only used for previous version)
2 - New improved formulation

1724 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

IDELG

Flag for node deletion.


0 - No deletion.
1 - The kinematic condition is suppressed on slave node, if the master
element is deleted. (The slave node is removed from the interface).

RUPT

Failure model (only available with FSPOT = 20, 21, 22) (Integer).
See comment 7.
0 - Failure when MAXND or MAXTD are reached;
1 - See comment 10.

IFILT

Filter flag (See comment 13)


Default = 0 (Integer = 0, 1)
0 - No filtering
1 - Filtering (alpha filter)

SRTID

Identification number of TABLEDi entry defining stress factor vs stress


rate (See comment 9).
No default (Integer > 0)

SNTID

Identification number of TABLEDi entry defining maximum normal stress vs


normal relative displacement(ND).
This function must be defined. (See comment 9)
No default (Integer > 0)

STTID

Identification number of TABLEDi entry defining maximum tangential


stress vs tangential relative displacement (TD).
This function must be defined. (See comment 9)
No default (Integer > 0)

MAXND

Maximum normal relative displacement.


Default = 1.0E20 (Real)

MAXTD

Maximum tangential relative displacement.


Default = 1.0E20 (Real)

FSTR

Stress scale factor (See comment 9)

Altair Engineering

OptiStruct 13.0 Reference Guide 1725


Proprietary Information of Altair Engineering

Field

Contents
Default = 1.00 (Real)

FSTRATE

Stress rate scale factor (See comment 9)


Default = 1.00 (Real)

FDIST

Distance scale factor (See comment 9)


Default = 1.00 (Real)

ALPHA

Stress filter alpha value


Default = 1.00 (Real)

STFAC

Interface stiffness scale factor. (Only used with FSPOT = 25)


Default = 1.00 (Real)

VISC

(Optional) Critical damping coefficient on interface stiffness (Only used


with FSPOT = 25)
Default = 0.05 (Real)

Comments
1. The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX2 property extension can be associated with a particular PCONT.
2. PCNTX2 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.
3. If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.
4. PCNXT2 is only valid for tied contact on TIE card.
5. Interface type 2 is a kinematic condition, no other kinematic condition should be set on
any nodes of the slave surface.
6. The default value for SRCHDIS is the average of the mater segments.
7. If IGNORE = 1 or 2, the slave nodes without a master segment found during the searching
are deleted from the interface;
If INGORE = 1 and SRCHDIS is blank, then the default value of the distance for searching
closest master segment is the average size of the master segments;
If IGNORE = 2 and SRCHDIS is blank, then the distance for searching closest master
segment is computed as follows for each slave node:

1726 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

d1 = 0.6 * (T s + T m)
d2 = 0.05 * T md
SRCHDIS = max(d1 , d2)
where,
T s - Thickness of the element connected to the slave node, for solids T s = 0.0
T m - Thickness of master segment, for solids T m = Element volume / Segment area
T md - Master segment diagonal
8. Master nodes of an interface type 2 may be slave nodes of another interface type 2 if the
hierarchy level of the first interface is lower than the hierarchy level of the second
interface. Hierarchy levels are only available with FSPOT=2.
9. For failure (FSPOT = 20, 21, 22), it could model glue connection. In this case, the force in
slave node will be scaled by reduced force coefficient f N (f T ), which is computed as;

The reduced force is compared to the maximum value:


If

, then N = 1, which means the force will not be reduced.

If
reduced.

, then

, which means the force will be then

Here the maximum value will be defined by you with:

Altair Engineering

OptiStruct 13.0 Reference Guide 1727


Proprietary Information of Altair Engineering

Where:
: maximum normal stress value defined by SNTID
: normal stress
: maximum tangential stress value defined by STTID
: tangential stress
FSTR: the input constant stress factor
SRTID: the input variable coefficient
SNTID and STTID: the input stress-displacement tables.
Once the rupture criterion (defined by Rupt) is reached, the contact will be deleted.
10. If RUPT = 1, the failure criterion is as follows:

11. If FSPOT = 30, slave mass/inertia/stiffness distribution to the master node is based on
the Kirschoff model: bi-cubic form functions are used instead of linear (standard
formulation). It allows a softer contact behavior since the element shape curvature is
taken into account in the force/moment transmission.
12. If IDELG = 1, then when a 4-node shell, a 3-node shell or a solid element is deleted, it is
also removed from the master side of the interface (kinematic condition is suppressed on
relative slave nodes).
13. If IFILT is set to 1, the normal and tangential stresses are filtered with an alpha filter, as
follows:

1728 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

14. FSPOT = 25 (penalty formulation) will keep the penalty formulation during the whole run.
The slave node (of this contact) could also be the slave node of another kinematic
option, like rigid body. The penalty stiffness is constant, calculated as the mean nodal
stiffness of master and slave side. The stiffness factor, STFAC, may be used to modify it,
if needed. The penalty stiffness will be multiplied by STFAC. A critical viscous damping
coefficient (VISC) allows damping to be applied to the interface stiffness.

Altair Engineering

OptiStruct 13.0 Reference Guide 1729


Proprietary Information of Altair Engineering

PCNTX5
Bulk Data Entry
PCNTX5 Extended CONTACT Property type 5 for Geometric Nonlinear Analysis
Description
Defines properties type 5 of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

(3)

PC NTX5

PID

STFAC

(4)

FRIC

IBC

(5)

(6)

GAP

TSTART

IRM

INAC TI

IFRIC

IFILT

FFAC

FRIC DAT

C1

C2

C3

(7)

(8)

IBAG

IDEL

C5

C6

(9)

(10)

TEND

C4

Example

(1)

(2)

PC ONT

34

PC NTX5

34

(3)

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property identification number of the associated PCONT.

(9)

(10)

No default (Integer > 0)


IBAG

Airbag vent holes closure flag in case of contact.


Default = 0 (Integer)

1730 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
0 - No closure
1 - Closure

IDEL

Flag for node and segment deletion. (See comment 5)


Default as defined by CONTPRM (Integer = 0, , 2)
0 - No deletion.
1 - When all the elements (shells, solids) associated to one segment are
deleted, the segment is removed from the master side of the interface.
Additionally, non-connected nodes are removed from the slave side of
the interface.
2 - When a shell or a solid element is deleted, the corresponding
segment is removed from the master side of the interface. Additionally,
non-connected nodes are removed from the slave side of the interface.

STFAC

Interface stiffness scale factor.


Default = 0.2 (Real > 0)

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

GAP

Gap for impact activation (See comment 4).


Default as defined by CONTPRM (Real > 0)

TSTART

Start time
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

IRM

Renumbering flag for segments of the master surface (Integer = 0, 1, 2).


0 - If segment is connected to a solid element its normal is reversed if
entering the solid element (the segment is renumbered).
1 - Normal is always reversed (segment 1234 is read 2143).

Altair Engineering

OptiStruct 13.0 Reference Guide 1731


Proprietary Information of Altair Engineering

Field

Contents
2 - Normal is never reversed (segment connected to a solid element are
not renumbered).

INACTI

Flag for handling of initial penetrations (See comment 6).


Default as defined by CONTPRM (Integer = 0, 3, 4)
0 - No action.
3 - Change slave node coordinates to avoid small initial penetrations.
4 - Change master node coordinates to avoid small initial penetrations.
Invalid entries are ignored.

IFRIC

Friction formulation flag (See comment 7).


Default as defined by CONTPRM (Character = COUL, GEN, DARM, REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.

IFILT

Friction filtering flag (See comment 8).


Default as defined by CONTPRM (Character = NO, SIMP, PER, CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

Friction filtering factor.


Default as defined by CONTPRM (Real = 0.0 < FFAC < 1.0)

FRICDAT

FRICDAT flag indicates that additional information for IFRIC will follow.
Only available when IFRIC = GEN, DARM or REN.

C1, C2, C3, Coefficients to define variable friction coefficient in IFRIC = GEN, DARM,
C4, C5, C6 REN.
Default as defined by CONTPRM (Real > 0)
Comments
1.

The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX5 property extension can be associated with a particular PCONT.

2.

PCNTX5 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM or IMPDYN. It is ignored for all other subcases.

1732 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

4.

In implicit analysis, different contact formulations are used for contact where slave and
master set do not overlap and where they overlap (self-contact).
In the case of self-contact, the gap cannot be zero and a constant gap is used. For
small initial gaps, the convergence will be more stable and faster if GAP is larger than the
initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example,
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.

5. Flag IDEL = 1 has a CPU cost higher than IDEL = 2.


6. INACTI = 3, 4 are only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations if several surface layers are defined in the
interfaces.
it may create initial energy if the node belongs to a spring element.
7.

IFRIC defines the friction model.


IFRIC = COUL Coulomb friction with F T < FRIC * F N.
For IFRIC > 0 the friction coefficient is set by a function ( = (p, V)), where p is the
pressure of the normal force on the master segment and V is the tangential velocity of
the slave node.
The following formulations are available:
IFRIC = 1 - Generalized viscous friction law
= FRIC + C1 * p + C2 * V + C3 * p * v + C4 * p2 + C5 * v2
IFRIC = 2 - Darmstad law
= C1 * e(C 2V ) * p2 + C3 * e(C 4V ) * p + C5 * e(C 6V )
IFRIC = 3 - Renard law

0 < V < C5

Altair Engineering

OptiStruct 13.0 Reference Guide 1733


Proprietary Information of Altair Engineering

C5 < V < C6

C6 < V

where:

The first critical velocity Vcr1


second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2, must be lower
than the maximum friction C3 (C1 < C3 and C2 < C3).
The minimum friction coefficient C4, must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2).
8.

IFILT defines the method for computing the friction filtering coefficient. If IFILT
the tangential friction forces are smoothed using a filter:

NO,

F T = * F'T + (1 - ) * F'T-1
where,
F T - Tangential force
F'T - Tangential force at time t
F'T-1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2
IFILT = CUTF = 2
9.

dt/FFAC, where dt/T = FFAC, T is the filtering period


* FFAC * dt, where FFAC is the cutting frequency

This card is represented as an extension to a PCONT property in HyperMesh.

1734 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCNTX7
Bulk Data Entry
PCNTX7 Extended CONTACT Property type 7 for Geometric Nonlinear Analysis
Description
Defines properties type 7 of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

PC NTX7

PID

ISTF

ITHE

IGAP

GAPFAC

GAPMAX

FPENMAX

STMIN

STMAX

MESHSIZ
E

DTMIN

IREMGAP

STFAC

FRIC

GAP

TSTART

TEND

INAC TI

VISS

IFORM

SENSID

IBC

(5)

IFRIC

IFILT

FFAC

C URVDA
T

G1

G2

FRIC DAT

C1

C2

C3

ADMDAT

NRADM

PADM

ANGLAD
M

THEDAT

RTHE

FRAD

DRAD

FHEATS

(6)

(7)

(8)

(9)

IBAG

IDEL

IC URV

IADM

VISF

BMULT

C4

C5

C6

TINT

ITHEF

(10)

FHEATM

Example

Altair Engineering

OptiStruct 13.0 Reference Guide 1735


Proprietary Information of Altair Engineering

(1)

(2)

PC ONT

34

PC NTX7

34

(3)

(4)

(5)

(6)

(7)

Field

Contents

PID

Property identification number of the associated PCONT.

(8)

(9)

(10)

No default (Integer > 0)


ISTF

Flag for stiffness definition (See comment 5).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - The stiffness is computed according to the master side
characteristics.
1 - STIF1 is used as interface stiffness.
2, 3, 4 and 5 - The interface stiffness is computed from both master and
slave characteristics.

ITHE

Heat contact flag (Integer).


Default = 0.
0 - No heat transfer.
1 - Heat transfer activated.

IGAP

Flag for gap definition.


Default as defined by CONTPRM (Character = CONST, VAR, VAR2, VAR3)
CONST - Gap is constant and equal to GAP (See comment 6).
VAR, VAR2, VAR3 - Gap is variable (in space, not in time) according to
the characteristics of the impacting surfaces and nodes (See comment
7).

IBAG

Airbag vent holes closure flag in case of contact.


Default = 0 (Integer).
0 - No closure.
1 - Closure.

IDEL

Flag for node and segment deletion.


Default as defined by CONTPRM (Integer = 0, , 2)

1736 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
0 - No deletion.
1 - When all the elements (shells, solids) associated to one segment are
deleted, the segment is removed from the master side of the interface.
Additionally, non-connected nodes are removed from the slave side of
the interface.
2 - When a shell or a solid element is deleted, the corresponding
segment is removed from the master side of the interface. Additionally,
non-connected nodes are removed from the slave side of the interface.

ICURV

Gap envelope with curvature (See comment 8).


Integer 0, ..., 3.
0 - No curvature.
1 - Spherical curvature.
2 - Cylindrical curvature.
3 - Automatic bicubic surface.

IADM

Computing local curvature flag for adaptive meshing (See comments 9


and 10).
Default = 0 (Integer 0, 1, 2).
0 - Not activated.
1 - Interface update according mesh size.
2 - Interface update according mesh size, penetration and angle.

GAPFAC

Gap scale factor (used only when IGAP = VAR2 and VAR3).
Default as defined by CONTPRM (Real > 0)

GAPMAX

Maximum gap (used only when IGAP = VAR2 and VAR3).


Default as defined by CONTPRM (Real > 0)

FPENMAX

Maximum fraction of initial penetration (See comment 13).


(Real)

STMIN

Minimum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

STMAX

Maximum stiffness (Only with ISTF > 1).

Altair Engineering

OptiStruct 13.0 Reference Guide 1737


Proprietary Information of Altair Engineering

Field

Contents
Default as defined by CONTPRM (Real > 0)

MESHSIZE

Percentage of mesh size (used only when IGAP = VAR3).


Default = 0.4 (Real, 0.0 < MESHSIZE < 1.0)

DTMIN

Limiting nodal time step (see comment 19)

IREMGAP

Flag to deactivate slave nodes if element size < gap value, in case of
self-impact contact (See comment 20).
Default = 1 (Integer)
1 - No slave node deactivation
2 - Deactivate slave nodes.

STFAC

Interface stiffness scale factor.


Default as defined by CONTPRM (Real > 0)

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

GAP

Gap for impact activation (See comments 4 and 6).


Default as defined by CONTPRM (Real > 0)

TSTART

Start time
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

INACTI

Flag for handling of initial penetrations (See comment 13).


Default as defined by CONTPRM (Integer = 0, 1, 2, 3, 5, or 6)
0
1
2
3

No action.
Deactivation of stiffness on nodes.
Deactivation of stiffness on elements.
Change slave node coordinates to avoid small initial penetrations.

1738 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
5 - GAP is variable with time and initial gap is adjusted as follows:
gap0 = gap - P0
6 - Gap is variable with time but initial gap is slightly de-penetrated as
follows:
gap0 = gap - P0 0.05*(gap - P0)
Invalid entries are ignored.

VISS

Critical damping coefficient on interface stiffness.


Default as defined by CONTPRM (Real > 0)

VISF

Critical damping coefficient on interface friction.


Default as defined by CONTPRM (Real > 0)

BMULT

Sorting factor. Can be used to speed up the sorting algorithm. Is


machine-dependent.
Default as defined by CONTPRM (Real > 0)

IFRIC

Friction formulation flag (See comment 14).


Default as defined by CONTPRM (Character = COUL, GEN, DARM, or REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.

IFILT

Friction filtering flag (See comment 15).


Default as defined by CONTPRM (Character = NO, SIMP, PER, or CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

Friction filtering factor.


Default as defined by CONTPRM (Real = 0.0 < FFAC < 1.0)

IFORM

Type of friction penalty formulation (See comment 16).


Default as defined by CONTPRM (Character = VISC, STIFF)
VISC - Viscous (total) formulation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1739


Proprietary Information of Altair Engineering

Field

Contents
STIFF - Stiffness (incremental) formulation.

SENSID

Sensor identifier to Activate/Deactivate the interface (See comment 21)


No default (Integer)
If a sensor identifier is defined, the activation/deactivation of the
interface is based on SENSID instead of TSTART or TSTOP.

CURVDAT

CURVDAT flag indicates that additional information about ICURV will


follow. Only available when ICURV = 1 or 2.

G1

First grid identifier (used only when ICURV = 1 or 2)


(Integer)

G2

Second grid identifier (used only when ICURV = 2, ignored when ICURV =
1)
(Integer)

FRICDAT

FRICDAT flag indicates that additional information for IFRIC will follow.
Only available when IFRIC = GEN, DARM or REN.

C1, C2, C3, Coefficients to define variable friction coefficient in IFRIC = GEN, DARM,
C4, C5, C6 REN.
Default as defined by CONTPRM (Real > 0)
ADMDAT

ADMDAT flag indicates that additional information about IADM will follow.
Only available when IADM = 2.

NRADM

Number of elements through a 90 degree radius 3 (used only when IADM


= 2)
(Integer)

PADM

Criteria on the percentage of penetration (used only when IADM = 2).


Default = 1.0 (Real)

ANGLADM

Angle criteria (used only when IADM = 2)


(Real)

THEDAT

THEDAT flag indicates that additional information about ITHE will follow.
Only available when ITHE = 1.

1740 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

RTHE

Heat conduction coefficient (used only when ITHE = 1, see comment 18)
(Real).

TINT

Interface temperature (used only when ITHE = 1)


(Real)

ITHEF

Heat contact formulation flag (used only when ITHE = 1, Integer).


0 - Exchange between constant temperature in the interface and shells
(slave side).
1 - Heat exchange between pieces in contact.

FRAD

Radiation factor (used only when ITHE = 1)


No default (Real)

DRAD

Maximum distance for radiation computation (used only when ITHE = 1)


No default (Real)

FHEATS

Frictional heating factor of the slave (used only when ITHE = 1, see
comment 25)
No default (Real)

FHEATM

Frictional heating factor of the master (used only when ITHE = 1, see
comment 25)
No default (Real)

Comments
1.

The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX7 property extension can be associated with a particular PCONT.

2.

PCNTX7 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

4.

In implicit analysis, different contact formulations are used for contact where slave and
master set do not overlap and where they overlap (self-contact).
In the case of self-contact, the gap cannot be zero and a constant gap is used. For
small initial gaps, the convergence will be more stable and faster if GAP is larger than the

Altair Engineering

OptiStruct 13.0 Reference Guide 1741


Proprietary Information of Altair Engineering

initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example,
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.
5.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V-3 for
solids, Ks = 0.5 * STFAC * E * t for shells.
In these equations, B is the Bulk Modulus, S is the segment area, and V is the volume of a
solid. There is no limitation to the value of stiffness factor (but a value larger than 1.0
can reduce the initial time step).
The interface stiffness is then K = max (STMIN, min (STMAX, K1)) with:
ISTF = 0, K1 = Km
ISTF = 2, K1 = 0.5 * (Km + Ks)
ISTF = 3, K1 = max (Km, Ks)
ISTF = 4, K1 = min (Km, Ks)
ISTF = 5, K1 = Km * Ks / (Km + Ks)
6. The default for the constant gap (IGAP = CONST) is the minimum of:
t, average thickness of the master shell elements;
l/10, l average side length of the master solid elements;
lmin/2, lmin smallest side length of all master segments (shell or solid).
7.

If IGAP = VAR, the variable gap is computed as gs + gm;


If IGAP = VAR2, the variable gap is computed as max(GAP, min(GAPFAC * (gs+gm),
GAPMAX);
If IGAP = VAR3, the variable gap is computed as max(GAP, min(GAPFAC * (gs+gm),
MESHSIZE * (gsl+gml), GAPMAX).
with:
gm - master element gap, with:
gm = t/2, t: thickness of the master element for shell elements.
gm = 0 for solid elements.
gs - slave node gap:
gs = 0 if the slave node is not connected to any element or is only connected to solid

1742 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

or spring elements.
gs = t/2, t - largest thickness of the shell elements connected to the slave node.
element.
gml - length of the smaller edge of element.
gsl - length of the smaller edge of elements connected to the slave nodes.
If the slave node is connected to multiple shells and/or beams or trusses, the largest
computed slave gap is used.
The variable gap is always at least equal to GAP.
8.

If ICURV = 1, a spherical curvature is defined for the gap with node_ID1 (center of the
sphere).
If ICURV = 2, a cylindrical curvature is defined for the gap with node_ID1 and node_ID2
(on the axis of the cylinder).
If ICURV = 3, the master surface shape is obtained with a bicubic interpolation, respecting
continuity of the coordinates and the normal from one segment to the other.
In case of a large change in curvature, this formulation might become unstable (will be
improved in future version).

9.

In case of adaptive meshing and IADM =1:


If the contact occurs in a zone (master side) whose radius of curvature is lower than the
element size (slave side), the element on the slave side will be divided (if not yet at
maximum level).

10. In case of adaptive meshing and IADM =2:

Altair Engineering

OptiStruct 13.0 Reference Guide 1743


Proprietary Information of Altair Engineering

If the contact occurs in a zone (master side) whose radius of curvature is lower than
NRadm times the element size (slave side), the element on the slave side will be divided
(if not yet at maximum level).
If the contact occurs in a zone (master side) where the angles between the normals are
greater than Angladm and the percentage of penetration is greater than Padm, the
element on the slave side will be divided (if not yet at maximum level).

11. The coefficients NRADM, PADM, and ANGLADM are used only adaptive meshing and IADM
= 2.
12. If GAPMAX is equal to zero, there is no maximum value for the gap.
13. INACTI = 3, is only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations if several surface layers are defined in the
interfaces.
it may create initial energy if the node belongs to a spring element.
INACTI = 5 is recommended for airbag simulation deployment.
INACTI = 6 is recommended instead of INACTI = 5, in order to avoid high frequency effects
into the interfaces.

1744 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

If FPENMAX is not equal to zero, nodes stiffness is deactivated if penetration >


FPENMAX*GAP, regardless of the value of INACTI.
14. IFRIC defines the friction model.
IFRIC = COUL Coulomb friction with F T < FRIC * F N.
For IFRIC > 0 the friction coefficient is set by a function ( =
(p, V)), where p is the
pressure of the normal force on the master segment and V is the tangential velocity of
the slave node.
The following formulations are available:
IFRIC = 1 - Generalized viscous friction law
= FRIC + C1 * p + C2 * V + C3 * p * v + C4 * p2 + C5 * v2
IFRIC = 2 - Darmstad law
= C1 * e(C 2V) * p2 + C3 * e(C 4V) * p + C5 * e(C 6V)
IFRIC = 3 - Renard law

0 < V < C5

C5 < V < C6

C6 < V

where:

The first critical velocity Vcr1


second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2, must be lower
than the maximum friction C3 (C1 < C3) and C2 < C3).

Altair Engineering

OptiStruct 13.0 Reference Guide 1745


Proprietary Information of Altair Engineering

The minimum friction coefficient C4, must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2).
15.
the tangential friction forces are smoothed using a filter:
F T = * F'T + (1 - ) * F'T-1
where,
F T - Tangential force
F'T - Tangential force at time t
F'T-1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2 dt/FFAC, where dt/T = FFAC, T is the filtering period
IFILT = CUTF = 2

* FFAC * dt, where FFAC is the cutting frequency

16. IFORM selects two types of contact friction penalty formulation.


The viscous (total) formulation (IFORM = VISC) computes an adhesive force as:
F adh

F T = min (F N, F adh)
The stiffness (incremental) formulation (IFORM = STIFF) computes an adhesive force as:
F adh = F Told + F T
F T = K * VT * dt
F Tnew = min (F N, F adh)
17. Exchange between shell and constant temperature contact TINT.
18. RTHE is the inverse of thermal resistance (units: [W/(m2K)]).
19. Slave segment contact is deactivated when the segment kinematic time step calculated
for this contact is lower than DTMIN.
20. With IREMGAP = 2, this allows the element size < gap values:

1746 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

In case of self-impact contact, when curvilinear distance (from a node of the master
segment to a slave node) is < gap*sqrt(2) (in initial configuration), then this slave node
will not be taken into account by this master segment, and it will not be deleted from the
contact for the other master segments.
21. When SENSID is defined for activation/deactivation of the interface, TSTART and TSTOP
are not taken into account.
22. If FRAD is not equal to zero, and d, the distance from the slave node to the master
segment, is in the range: Gap < d < DRAD, then radiation is calculated. The radiant heat
transfer conductance is calculated as:

Where,
2

is the Stefan Boltzman constant,

is the emissivity of the slave surface, and

is the emissivity of the master surface.

23. If FRAD is not equals to zero, then the default value of DRAD is calculated as the
maximum of:
upper value of the gap (at time 0) among all nodes;
smallest side length of slave element.
24. A very high value of DRAD is not recommended as it may reduce the performance of the
solver
25. Frictional energy is converted into heat when heat transfer is activated (ITHE > 0) on the
interface. Options FHEATS and FHEATM are used to control this option.
When FHEATS and FHEATM = 0, the conversion of the frictional sliding energy to heat is
not activated. Non-zero values of FHEATS and FHEATM define the fraction of this energy
which is converted into heat and transferred to the slave and master respectively.
The frictional heat QFric is defined as follows:

Altair Engineering

OptiStruct 13.0 Reference Guide 1747


Proprietary Information of Altair Engineering

If IFORM = 2 (a stiffness formulation):

Slave:

Master:

(ITHEF=1)

If IFORM = 1 (a penalty formulation):


Slave:
Master:

(ITHEF=1)

26. This card is represented as an extension to a PCONT property in HyperMesh.

1748 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCNTX11
Bulk Data Entry
PCNTX11 Extended Contact (CONTX11) Property type 11 for Geometric Nonlinear Analysis
Description
Defines properties type 11 of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

PC NTX11

PID

(3)

(4)

(5)

(6)

ISTF

(7)

(9)

IGAP

(10)

IDEL

STMIN

STMAX

MESHSIZE

DTMIN

STFAC

FRIC

GAP

TSTART

TEND

STF1

INAC TI

VISS

VISF

IBC

(8)

BMULT

Example

(1)

(2)

PC ONT

34

PC NTX11

34

(3)

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property identification number of the associated PCONT.

(9)

(10)

No default (Integer > 0)


ISTF

Flag for stiffness definition (See comment 6).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - STFAC is a stiffness scale factor and the stiffness is computed
according to the master side characteristics.
1 - STIF1 is used as interface stiffness.
2, 3, 4 and 5 - STFAC is a stiffness scale factor and the interface

Altair Engineering

OptiStruct 13.0 Reference Guide 1749


Proprietary Information of Altair Engineering

Field

Contents
stiffness is computed from both master and slave characteristics.

IGAP

Flag for gap definition.


Default as defined by CONTPRM (Character = CONST, VAR, VAR3)
CONST - Gap is a constant and equal to GAP (See comment 7).
VAR - Gap is a variable (in space, not in time) according to the
characteristics of the impacted master line and the impacting slave
nodes (See comment 8).
VAR3 - Gap is a variable according to the characteristics of the impacted
master line and impacting slave node + gap is taken into account the
size of the elements.

IDEL

Flag for node and segment deletion.


Default as defined by CONTPRM (Integer = 0, , 2)
0 - No deletion.
1 - When all the elements (shells and solids) associated to one segment
are deleted, the segment is removed from the master side of the
interface. Additionally, non-connected nodes are removed from the
slave side of the interface.
2 - When a shell or a solid element is deleted, the corresponding
segment is removed from the master side of the interface. Additionally,
non-connected nodes are removed from the slave side of the interface.

STMIN

Minimum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

STMAX

Maximum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

MESHSIZE

Percentage of mesh size (Used only when IGAP = VAR3).


Default = 0.4 (Real, 0.0 < MESHSIZE < 1.0)

DTMIN

Limiting nodal time step (see comment 10)


No default (Real > 0)

STFAC
Default as defined by CONTPRM (Real > 0)

1750 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

GAP

Gap for impact activation (See comments 7 and 8).


Default as defined by CONTPRM (Real > 0)

TSTART

Start time.
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

STIF1

Interface stiffness (Only with ISTF = 1).


Default = 0.0 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

INACTI

Flag for handling of initial penetrations (See comment 8).


Default as defined by CONTPRM (Integer = 0, 1, 2, 3, 5, or 6)
0
1
2
3
5

No action.
Deactivation of stiffness on nodes.
Deactivation of stiffness on elements.
Change slave node coordinates to avoid small initial penetrations.
GAP is a variable with time and initial gap is adjusted as follows:
gap0 = gap - P0

6 - Gap is variable with time but initial gap is slightly de-penetrated as


follows:
gap0 = gap - P0 0.05*(gap - P0)
Invalid entries are ignored.
VISS

Critical damping coefficient on interface stiffness.


Default as defined by CONTPRM (Real > 0)

VISF

Critical damping coefficient on interface friction.


Default as defined by CONTPRM (Real > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1751


Proprietary Information of Altair Engineering

Field

Contents

BMULT

Sorting factor. Can be used to speed up the sorting algorithm and is


machine-dependent.
Default as defined by CONTPRM (Real > 0)

Comments
1. The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX11 property extension can be associated with a particular PCONT.
2. PCNTX11 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.
3. If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.
4. PCNTX11 defines the properties of contact interface type CONTX11, it describes the edge
to edge or line to line interface. This interface simulates impact between lines, a line can
be a beam or truss element or a shell edge or spring elements. The interface properties
are:
impacts occur between a master and a slave line;
a slave line can impact on one or more master lines;
a line can belong to the master and the slave side. This allows self impact;
this interface can be used in addition to the interface type 7 PCNTX7 to solve the
edge to edge limitation of interface type 7.
5.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V-3 for
solids, Ks = 0.5 * STFAC * E * t for shells.
In these equations, B is the Bulk Modulus, S is the segment area, and V is the volume of a
solid. There is no limitation to the value of stiffness factor (but a value larger than 1.0
can reduce the initial time step).
The interface stiffness is then, K = max (STMIN, min (STMAX, K1)) with:
ISTF = 0, K1 = Km
ISTF = 2, K1 = 0.5 * (Km + Ks)
ISTF = 3, K1 = max (Km, Ks)
ISTF = 4, K1 = min (Km, Ks)

1752 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

ISTF = 5, K1 = Km * Ks / (Km + Ks)


6. The default for the constant gap (IGAP = CONST) is equal to GAP.
7. If IGAP = VAR, the variable gap is computed as: gm + gs
with:
gm - master element gap with
gm = t/2, t: thickness of the master element for shell elements.
gm = L/10, L - length of the smallest side of a solid element.
element.
gm = 0 for spring elements.
gs - slave element gap is computed as the same way.
If the slave node is connected to multiple shells and/or beams or trusses, the largest
computed slave gap is used.
The variable gap is always at least equal to GAP.
8. INACTI = 3, is only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations, if several surface layers are defined in the
interfaces.
it may create initial energy, if the node belongs to a spring element.
INACTI = 5 is recommended for airbag simulation deployment.
INACTI = 6 is recommended instead of INACTI = 5, in order to avoid high frequency effects
into the interfaces.

9. The sorting factor BUMULT is used to speed up the sorting algorithm, it is machine
dependent.

Altair Engineering

OptiStruct 13.0 Reference Guide 1753


Proprietary Information of Altair Engineering

10. Slave segment is deactivated from the contact when the segment kinematic time step
calculated for this contact becomes smaller than DTMIN.

1754 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCNTX20
Bulk Data Entry
PCNTX20 Extended CONTACT Property type 20 for Geometric Nonlinear Analysis
Description
Defines properties type 20 of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PC NTX20

PID

ISYM

IEDGE

GRNDID

(7)

(8)

(9)

(10)

EDGEAngle

IGAP

IBAG

IDEL

FPENMAX

STFAC

FRIC

GAP

IBC

TSATAT

TEND

INAC TI

VISS

VISF

C4

C5

IFRIC

IFILT

FFAC

IFORM

FRIC DAT

C1

C2

C3

C6

Example

(1)

(2)

PC ONT

34

PC NTX20

34

(3)

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property identification number of the associated PCONT.

(9)

(10)

No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1755


Proprietary Information of Altair Engineering

Field

Contents

ISYM

Flag for symmetric contact.


Default as defined by CONTPRM (Character = SYM or UNSYM)
SYM Symmetric contact.
UNSYM Master-slave contact.
If SSID defines a grid set, the contact is always a master-slave contact.

IEDGE

Flag for edge generation from slave and master surfaces.


Default as defined by CONTPRM (Character = NO, ALL, BORD, FEAT)
NO No edge generation.
All All segment edges are included.
BORD External border of slave and master surface is used.
FEAT External border as well as features defined by FANG are used.

GRNDID

Optional nodes group identifier (Integer).

EdgeAngle

Edges angle (used only if IEDGE = FEAT)


Default = 91 (Real).
If angle between two edges is smaller than EdgeAngle, the edge is
considered.

IGAP

Flag for gap definition.


Default as defined by CONTPRM (Character = CONST or VAR)
CONST - Gap is constant and equal to GAP (See comment 6).
VAR - Gap is variable (in space, not in time) according to the
characteristics of the impacting surfaces and nodes (See comment 7).

IBAG

Airbag vent holes closure flag in case of contact.


Default = 0 (Integer).
0 - No closure.
1 - Closure.

IDEL

Flag for node and segment deletion.


Default as defined by CONTPRM (Integer = 0, , 2)
0 - No deletion.
1 - When all the elements (shells and solids) associated to one segment
are deleted, the segment is removed from the master side of the

1756 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
interface. Additionally, non-connected nodes are removed from the
slave side of the interface.
2 - When a shell or a solid element is deleted, the corresponding
segment is removed from the master side of the interface. Additionally,
non-connected nodes are removed from the slave side of the interface.

FPENMAX

Maximum initial penetration factor (0 < FPENMAX < 1) (See comment 8).
Default = 1.0 (Real)

STFAC

Interface stiffness scale factor.


Default as defined by CONTPRM (Real > 0)

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

GAP

Gap for impact activation (See comments 4 and 6).


Default as defined by CONTPRM (Real > 0)

TSTART

Start time.
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

INACTI

Flag for handling of initial penetrations (See comment 9).


Default as defined by CONTPRM (Integer = 0, 1, 2, 3, or 5)
0 - No action.
1 - Deactivation of stiffness on nodes.
2 - Deactivation of stiffness on elements.
3 - Change slave node coordinates to avoid small initial penetrations.
5 - Gap is variable with time but initial gap is slightly de-penetrated as
follows:
gap0 = gap - P0 0.05 * (gap - P0)
Valid in explicit analysis: 0, 1, 2, 3 and 5.

Altair Engineering

OptiStruct 13.0 Reference Guide 1757


Proprietary Information of Altair Engineering

Field

Contents
Invalid entries are ignored.

VISS

Critical damping coefficient on interface stiffness.


Default as defined by CONTPRM (Real > 0)

VISF

Critical damping coefficient on interface friction.


Default as defined by CONTPRM (Real > 0)

IFRIC

Friction formulation flag (See comment 10).


Default as defined by CONTPRM (Character = COUL, GEN, DARM, REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.

IFILT

Friction filtering flag (See comment 11).


Default as defined by CONTPRM (Character = NO, SIMP, PER, CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

Friction filtering factor.


Default as defined by CONTPRM (Real = 0.0 < FFAC < 1.0)

IFORM

Type of friction penalty formulation (See comment 12).


Default as defined by CONTPRM (Character = VISC, STIFF)
VISC - Viscous (total) formulation.
STIFF - Stiffness (incremental) formulation.

FRICDAT

FRICDAT flag indicates that additional information for IFRIC will follow.
Only available when IFRIC = GEN, DARM or REN.

C1, C2, C3, Coefficients to define variable friction coefficient in IFRIC = GEN, DARM,
C4, C5, C6 REN.
Default as defined by CONTPRM (Real > 0)
Comments
1.

The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX20 property extension can be associated with a particular PCONT.

1758 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

PCNTX20 is only applied in geometric nonlinear explicit dynamic analysis subcase which is
defined by ANALYSIS = EXPDYN, but not supported in NLGEOM or IMPDYN subcases. It is
ignored for all other subcases.

3.

If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

4.

In implicit analysis, different contact formulations are used for contact where slave and
master set do not overlap and where they overlap (self-contact).
In the case of self-contact, the gap cannot be zero and a constant gap is used. For
small initial gaps, the convergence will be more stable and faster if GAP is larger than the
initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example,
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.

5.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V-3 for
solids, Ks = 0.5 * STFAC * E * t for shells.
In these equations, B is the Bulk Modulus, S is the segment area, and V is the volume of a
solid. There is no limitation to the value of stiffness factor (but a value larger than 1.0
can reduce the initial time step).
The interface stiffness is then K = max (STMIN, min (STMAX, K1)) with:
ISTF = 0, K1 = Km
ISTF = 2, K1 = 0.5 * (Km + Ks)
ISTF = 3, K1 = max (Km, Ks)
ISTF = 4, K1 = min (Km, Ks)
ISTF = 5, K1 = Km * Ks / (Km + Ks)
6. The default for the constant gap (IGAP = CONST) is the minimum of:
t, average thickness of the master shell elements;
l/10, l average side length of the master solid elements;
lmin/2, lmin smallest side length of all master segments (shell or solid).
7. The variable gap (IGAP = VAR) is computed as: gs + gm
with:

Altair Engineering

OptiStruct 13.0 Reference Guide 1759


Proprietary Information of Altair Engineering

gm - master element gap with


gm = t/2, t: thickness of the master element for shell elements.
gm = 0 for solid elements.
gs - slave node gap:
gs = 0 if the slave node is not connected to any element or is only connected to solid
or spring elements.
gs = t/2, t - largest thickness of the shell elements connected to the slave node.
element.
If the slave node is connected to multiple shells and/or beams or trusses, the largest
computed slave gap is used.
8. Maximum penetration value is set as a fraction of the actual gap (including variable gap):
Penmax = FPENMAX * gap
If the initial penetration of a slave node is greater than the calculated maximum value
(Penmax), the node will be deactivated from the interface (node stiffness deactivation).
9. INACTI = 3, is only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations if several surface layers are defined in the
interfaces.
it may create initial energy if the node belongs to a spring element.
INACTI = 5 works as follows:

10. IFRIC defines the friction model.


IFRIC = COUL Coulomb friction with F T < FRIC * F N.
For IFRIC > 0, the friction coefficient is set by a function (

p, V

1760 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

where, p is the pressure of the normal force on the master segment and V is the
tangential velocity of the slave node.
The following formulations are available:
IFRIC = 1 - Generalized viscous friction law
= FRIC + C1 * p + C2 * V + C3 * p * v + C4 * p2 + C5 * v2
IFRIC = 2 - Darmstad law
= C1 * e(C 2V ) * p2 + C3 * e(C 4V ) * p + C5 * e(C 6V )
IFRIC = 3 - Renard law

0 < V < C5

C5 < V < C6

C6 < V

where:

The first critical velocity Vcr1


second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2, must be lower
than the maximum friction C3 (C1 < C3 and C2 < C3).
The minimum friction coefficient C4, must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2).
11. IFILT defines the method for computing the friction filtering coefficient. If IFILT
the tangential friction forces are smoothed using a filter:

NO,

F T = * F'T + (1 - ) * F'T-1

Altair Engineering

OptiStruct 13.0 Reference Guide 1761


Proprietary Information of Altair Engineering

where,
F T - Tangential force
F'T - Tangential force at time t
F'T-1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2

dt/FFAC, where dt/T = FFAC, T is the filtering period

IFILT = CUTF = 2

* FFAC * dt, where FFAC is the cutting frequency

12. IFORM selects two types of contact friction penalty formulation.


The viscous (total) formulation (IFORM = VISC) computes an adhesive force as:
F adh

F T = min (F N, F adh)
The stiffness (incremental) formulation (IFORM = STIFF) computes an adhesive force as:
F adh = F Told + F T
F T = K * VT * dt
F Tnew = min (F N, F adh)
13. This card is represented as an extension to a PCONT property in HyperMesh.

1762 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCNTX24
Bulk Data Entry
PCNTX24 Extended CONTACT Property type 24 for Geometric Nonlinear Analysis
Description
Defines properties type 24 of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

PC NTX24

PID

(3)

(4)

(5)

(6)

(7)

(8)

GAPMAXs

GAPMAXm

(9)

(10)

ISTF

STMIN

STMAX

STFAC

FRIC

IGAP0

IBC

IFRIC

IFILT

FFAC

FRIC DAT

C1

C2

IPEN0

IPENMAX

TSTART

TEND

INAC TI

VISS

IPENMIN

SENSID

C3

C4

C5

C6

Example

(1)

(2)

PC ONT

34

PC NTX24

34

Altair Engineering

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 1763


Proprietary Information of Altair Engineering

Field

Contents

PID

Property identification number of the corresponding PCONT entry.


No default (Integer > 0)

ISTF

Flag for stiffness definition (See comment 5).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - The stiffness is computed according to the master side
characteristics.
2, 3, 4 and 5 - The interface stiffness is computed from both master and
slave characteristics.

GAPMAXs

Slave maximum gaps.


No default (Real)

GAPMAXm

Master maximum gaps.


No default (Real)

STMIN

Minimum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

STMAX

Maximum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

IGAP0

Gap modification flag for slave shell nodes on the free edges.
(Integer)
0 - No change
1 - Set gap to zero for the slave shell nodes

IPEN0

Initial penetration detection flag (See comment 14)


(Integer)
0 - default method (excluding auto-impact in each part)
1 - method 1 (including auto-impact in each part)

IPENMAX

Maximum initial penetration: Penetration higher than this value will not be
taken into account.
(Real)

IPENMIN

Minimum initial penetration: Penetration higher than this value will be

1764 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
taken into account.
(Real)

STFAC

Interface stiffness scale factor.


Default as defined by CONTPRM (Real > 0)

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

TSTART

Start time
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

INACTI

Flag for handling of initial penetrations (See comment 8).


Default as defined by CONTPRM (Integer = 0, 1, -1, 5)
0 - only tiny initial penetrations (1.0e-08) will be taken into account.
1 - all initial penetrations will be ignored.
-1 - all initial penetrations will be taken into account.
5 - GAP is variable with time and initial gap is adjusted as follows:
gap0 = gap - P0 , where P0 is the initial penetration

VISS

Critical damping coefficient on interface stiffness.


Default as defined by CONTPRM (Real > 0)

IFRIC

Friction formulation flag (See comment 9).


Default as defined by CONTPRM (Character = COUL, GEN, DARM, REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.

IFILT

Friction filtering flag (See comment 10).

Altair Engineering

OptiStruct 13.0 Reference Guide 1765


Proprietary Information of Altair Engineering

Field

Contents
Default as defined by CONTPRM (Character = NO, SIMP, PER, CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

Friction filtering factor.


Default as defined by CONTPRM

SENSID

Sensor identifier to Activate/Deactivate the interface (See comment 12)


No default (Integer)
If a sensor identifier is defined, the activation/deactivation of interface is
based on the sensor and not on Tstart or Tstop.

FRICDAT

FRICDAT flag indicates that additional information for IFRIC will follow.
Only available when IFRIC = GEN, DARM or REN.

C1, C2, C3, Coefficients to define variable friction coefficient in IFRIC = GEN, DARM,
C4, C5, C6 REN.
Default as defined by CONTPRM (Real > 0)
Comments
1.

The property identification number must be that of an existing PCONT bulk data entry.
Only one PCNTX24 property extension can be associated with a particular PCONT.

2.

PCNTX24 is only supported for geometric nonlinear explicit dynamic analysis subcase
defined by ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

4.

In implicit analysis, different contact formulations are used for contact where slave and
master set do not overlap and where they overlap (self-contact).
In the case of self-contact, the gap cannot be zero and a constant gap is used. For
small initial gaps, the convergence will be more stable and faster if GAP is larger than the
initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example,
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.

1766 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V-3 for
solids, Ks = 0.5 * STFAC * E * t for shells.
In these equations, B is the Bulk Modulus, S is the segment area, and V is the volume of a
solid. There is no limitation to the value of stiffness factor (but a value larger than 1.0
can reduce the initial time step).
The interface stiffness is then K = max (STMIN, min (STMAX, K1)) with:
ISTF = 0, K1 = Km
ISTF = 2, K1 = 0.5 * (Km + Ks)
ISTF = 3, K1 = max (Km, Ks)
ISTF = 4, K1 = min (Km, Ks)
ISTF = 5, K1 = Km * Ks / (Km + Ks)
6.

The gap is computed automatically (similar with IGAP = VAR on PCNTX7) for each impact
as gs + gm;
with:
gm - master element gap, with:
gm = t/2, t: thickness of the master element for shell elements.
gm = 0 for solid elements.
gs - slave node gap:
gs = 0 if the slave node is not connected to any element or is only connected to solid
or spring elements.
gs = t/2, t - largest thickness of the shell elements connected to the slave node.
element.
gm and gs are limited separately by GAPMAXm and GAPMAXs before the gap
computation.

7.

The coefficients C1 - C6 are used to define a variable friction coefficient

8.

INACTI = 0 ignores the initial penetrations, but the contacts are not deleted, new
contact will be well detected once the penetrations are disappeared. INACTI = 5 is similar
to the one of interface type 7, but once the initial penetration is gone, the new contact
will be detected using not-adjusted gap (P0 is reset to zero).

9.

IFRIC defines the friction model.


IFRIC = COUL Coulomb friction with F T < FRIC * F N.

Altair Engineering

OptiStruct 13.0 Reference Guide 1767


Proprietary Information of Altair Engineering

p, V

For IFRIC > 0 the friction coefficient is set by a function (

where, p is the pressure of the normal force on the master segment and V is the
tangential velocity of the slave node.
The following formulations are available:
IFRIC = GEN - Generalized viscous friction law
FRIC + C1 * p + C2 * V + C3 * p * v + C4 * p2 + C5 * v2
IFRIC = DARM - Darmstad law
= C1 * e(C 2V) * p2 + C3 * e(C 4V) * p + C5 * e(C 6V)
IFRIC = REN - Renard law

0 < V < C5

C5 < V < C6

C6 < V

where:

The first critical velocity Vcr1


second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2, must be lower
than the maximum friction C3 (C1 < C3 and C2 < C3).
The minimum friction coefficient C4, must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2).
10. IFILT defines the method for computing the friction filtering coefficient. If IFILT
the tangential friction forces are smoothed using a filter:

1768 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

NO,

Altair Engineering

F T = * F'T + (1 - ) * F'T-1
where,
F T - Tangential force
F'T - Tangential force at time t
F'T-1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2

dt/FFAC, where dt/T = FFAC, T is the filtering period

IFILT = CUTF = 2

* FFAC * dt, where FFAC is the cutting frequency

11. IFORM selects two types of contact friction penalty formulation.


The viscous (total) formulation (IFORM = VISC) computes an adhesive force as:
F adh

F T = min (F N, F adh)
The stiffness (incremental) formulation (IFORM = STIFF) computes an adhesive force as:
F adh = F Told + F T
F T = K * VT * dt
F Tnew = min (F N, F adh)
12. When SENSID is defined for activation/deactivation of the interface, TSTART and TSTOP
are not taken into account.
13. When the contact type is the symmetric surface to surface, the output normal contact
forces in TH file are correctly calculated if the two surfaces are well separated.
14. IPEN0 = 0 excludes the initial auto-impacts in the same part (shell and solid elements
only). IPEN0 = 1 takes into account the initial auto-impacts in the same part, but in some
complex situations, wrong initial penetrations might be given.
15. For implicit test: Interface type24 is now only available with SMP. The default of ISTF will
be set to 4. The default INACTI will be set to -1 .
16. This card is represented as an extension to a PCONT property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1769


Proprietary Information of Altair Engineering

PCOMP
Bulk Data Entry
PCOMP Composite Laminate Property
Description
Defines the structure and properties of an n-ply composite laminate material.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PC OMP

PID

Z0

NSM

SB

FT

TREF

GE

LAM

MID1

T1

THETA1

SOUT1

MID2

T2

THETA2

SOUT2

MID3

T3

THETA3

SOUT3

etc.

DS

Example

(1)

(2)

(3)

PC OMP

100

-0.5

120

0.2

120

0.2

(4)

(5)

(6)

(7)

1.E5

STRN

100.

0.0

YES

120

0.6

0.0

YES

(8)

(9)

0.0

NO

(10)

1.0

Field

Contents

PID

Unique composite property identification number.


No default (Integer > 0)

1770 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Z0

Real number or character input (Top/Bottom)


Real Number - It represents the distance from the shell element reference
plane to the bottom surface of the shell (Default = -0.5 * Thick, Thick
being the composite total thickness (Real or blank)).
Character Input - See comment 17

NSM

Nonstructural mass per unit area.


No default (Real)

SB

Allowable inter-laminar shear stress (shear stress in the bonding material).


Disregarded if blank or 0.0.
No default (Real > 0.0)

FT

Failure theory code. If blank, no failure calculations are performed. The


following failure theory codes are supported:
HILL for Hill theory,
HOFF for Hoffman theory,
TSAI for Tsai-Wu theory,
STRN for Maximum Strain Theory.
See comments 13 through 15.
Default = no failure calculations are performed (HILL, HOFF, TSAI, or
STRN)

TREF

Reference (stress free) temperature. See comment 1.


Default = 0.0 (Real)

GE

Damping coefficient. See comments 10 and 11.


Default = 0.0 (Real)

LAM

Laminate option. If blank, all plies must be specified and all stiffness
terms are developed. The following options are supported:
SYM: Only plies on the bottom half of the composite lay-up needs to be
specified. These plies are automatically symmetrically reflected to the top
half of the composite and given consecutive numbers from bottom to top.

Altair Engineering

OptiStruct 13.0 Reference Guide 1771


Proprietary Information of Altair Engineering

Field

Contents
MEM: All plies must be specified, but only membrane terms MID1 are
developed. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
BEND: All plies must be specified, but only bending terms MID2 are
developed. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
SMEAR: All plies must be specified, stacking sequence is ignored, and
MID1 is set equal to MID2 on the derived equivalent PSHELL, while MID3,
MID4, TS/T, and 12I/T**3 are set to zero. Prescribed Z0 is ignored
(assumed to be: -0.5* Thick).
SMEARZ0: All plies must be specified, stacking sequence is ignored. While
the laminate is still considered to be made of homogenized (smeared)
material, the effect of offset Z0 is taken into account. Hence, if Z0 is not
equal to -0.5*Thick, the equivalent PSHELL will include MID1, MID2 and
MID4. MID3 is still set to zero, that is no transverse shear deformation is
considered.
SMCORE: All plies must be specified. The last ply specifies core properties
and the previous plies specify face sheet properties. The face sheet
properties are calculated without regard for stacking sequence; half of the
total face sheet thickness is then placed on top of the core, and half is
placed on the bottom, to produce a symmetric laminate. Stiffness of the
core is ignored while its density is included in inertia calculations.
Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
SYMEM: Only plies on the bottom half of the composite lay-up needs to
be specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom to
top. Only membrane terms are developed for the full laminate. Prescribed
Z0 is ignored (assumed to be: -0.5* Thick).
SYBEND: Only plies on the bottom half of the composite lay-up needs to
be specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom to
top. Only bending terms are developed for the full laminate. Prescribed
Z0 is ignored (assumed to be: -0.5* Thick).
SYSMEAR: Only plies on the bottom half of the composite lay-up needs to
be specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom to
top. Stacking sequence is ignored, and MID1 is set equal to MID2 on the
derived equivalent PSHELL, while MID3, MID4, TS/T and 12I/T**3 are set
to zero. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
Default = blank, that is all plies must be specified (SYM, MEM, BEND,
SMEAR, SMCORE, SYMEM, SYBEND or SYSMEAR)

1772 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

MIDi

Material IDs of individual plies. The plies are identified by consecutively


numbering them from 1 at the bottom layer. The MIDs must refer to
MAT1, MAT2, MAT4, MAT5, or MAT8 bulk data entries. If MIDi is not
specified, default is the last defined MIDi.
Default = last defined MIDi (Integer>0 or blank, except that MID1 must be
specified)

Ti

Thicknesses of individual plies. If Ti is not specified, default is the last


defined Ti.
Default = last defined Ti (Real > 0.0 or blank, except that T1 must be
specified)

THETAi

Orientation angle, in degrees, of the longitudinal direction of each ply


relative to the x-axis of the material coordinate system associated with a
given element. If no material coordinate system is prescribed for the
element, the angle is measured relative to side 1-2 of this element.
Default = 0.0 (Real or blank)

SOUTi

Stress, Strain and Failure Index output request for individual plies. See
comments 2 and 3.
Default = NO (YES or NO)

DS

Design switch. If non-zero (1.0), the elements associated with this


PCOMP data are included in the topology design volume or space.
Default = blank (Real = 1.0 or blank)

Comments
1.

TREF specified on the PCOMP entry overrides reference temperatures given for individual
ply materials. If TREF is not specified (blank) on the PCOMP card, then all the ply
materials must have the same reference temperature.

2.

Stress, Strain and Failure Index output for individual plies is activated by setting SOUTi to
YES for a given ply. In addition, the I/O Options CSTRESS (controlling Stress and Failure
Index output) and/or CSTRAIN (controlling Strain output) must be defined. Failure Index
output also requires that the FT and SB fields be defined and that stress/strain allowables
on the referenced materials are defined.

3.

An additional piece of information available with ply results is "failure index for the
element," which is the maximum of failure indices for individual plies in this element. Note
that only the plies with SOUTi set to YES are considered in the evaluation of this
maximum.

Altair Engineering

OptiStruct 13.0 Reference Guide 1773


Proprietary Information of Altair Engineering

4.

If all plies specify zero transverse shear coefficients (G1Z, G2Z on MAT8 card, isotropic G
for MAT1, not available for MAT2), the in-plane shear modulus will be used to determine
transverse shear stiffness of the composite.
Note: If just one layer has a nonzero value specified for
transverse shear modulus, this substitution is not
being performed, and user-specified values are being
used for all plies.

5.

The signs given to stress limits for compression and tension (ST, SC, for MAT1; Xt, Xc,
and so on for MAT8) are of no relevance. Absolute values are taken and used in the
appropriate context to calculate failure indices.

6.

For com
bottom and top surfaces of the shell are produced.
Note: These shell stresses are calculated using
homogenized shell properties, and should be
interpreted with caution.

7.
This is because the membrane-bending coupling resulting from composite offset is not
included in the differential stiffness matrix. Hence, the preferred method of incorporating
offset in buckling analysis is the element offset ZOFFS.
8.

Element GRID thicknesses cannot be defined for elements that reference PCOMP data.

9.

Plies are listed from the bottom surface upwards, in respect to the elements normal
direction. In the image below, (a) shows the stacking sequence for a non-symmetrical
laminate, and (b) shows the stacking sequence for a symmetrical laminate.

10. GE given on the PCOMP entry will be used for the element, and the values supplied on
material entries for individual plies are ignored. You are responsible for supplying the
equivalent damping value on the PCOMP entry.
11. To obtain the damping coefficient GE, multiply the critical damping ratio C/C0 by 2.0.
12. For convenience, element output for the SMEAR and SMCORE options includes both
homogenized shell stresses and individual ply stresses. However, because stacking
sequence is ignored in these options, individual ply stresses will only be valid in cases of

1774 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

pure membrane deformation.


13. Note that Hills failure theory does not differentiate between compressive and tensile
strength. Hence, while different values of respective strength limits are accepted, it is
still recommended that Xt is set to be equal to Xc and Yt is set to be equal to Yc when
this criteria is used. Xt and Xc are allowable tensile and compressive stresses in the
principle x direction of the material. Yt and Yc are allowable tensile and compressive
stresses in the principle y direction of the material.
14.

Failure index calculation according to Maximum Strain Theory is based on mechanical


component of strain only, not on total strain. This is because only the mechanical strain
contributes to actual damage of the respective ply (pure thermal expansion produces no
damaging effects).

15. According to the formula, some failure criteria (for example, Tsai-Wu and Hoffman) would
produce a negative ply failure, depending on the problem.
16. If PARAM, SRCOMPS, YES is added to the input file, strength ratios with respect to
designated failure theory are output for composite elements that have failure indices
requested.
17. The following two formats are permissible for the Z0 field:
Real Number:
It represents the distance from the shell element reference plane to the bottom surface
of the shell (Default = -0.5 * Thick, Thick being the composite total thickness (Real or
blank)).
Surface:
Top:
The shell reference plane, the plane defined by the grid points, and the top surface of the
shell are coplanar.
This makes the effective "Real" Z0 value equal to the composite total thickness (-1.0 *
Thick). See Figure 1.

Figure 1: Top option for Z0

Bottom:
The shell reference plane, the plane defined by the grid points, and the bottom surface of
the shell are coplanar.

Altair Engineering

OptiStruct 13.0 Reference Guide 1775


Proprietary Information of Altair Engineering

This makes the effective "Real" Z0 value equal to 0. See Figure 2.

Figure 2: Bottom option for Z0

Automatic offset control is available in composite free-size and sizing optimization where
the specified offset values are automatically updated based on thickness changes.
18. This card is represented as a property in HyperMesh.

1776 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PCOMPG
Bulk Data Entry
PCOMPG Composite Laminate Property
Description
Defines the structure and properties of a composite laminate material, allowing for global ply
identification.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PC OMPG

PID

Z0

NSM

SB

FT

TREF

GE

LAM

GPLYID1

MID1

T1

THETA1

SOUT1

GPLYID2

MID2

T2

THETA2

SOUT2

DS

Example

(1)

(2)

(3)

PC OMP

100

-0.5

101

120

103

(4)

(5)

(6)

(7)

1.E5

STRN

100.

0.2

0.0

YES

120

0.6

0.0

NO

120

0.2

0.0

YES

(8)

(9)

(10)

1.0

Altair Engineering

OptiStruct 13.0 Reference Guide 1777


Proprietary Information of Altair Engineering

Field

Contents

PID

Unique composite property identification number.


No default (Integer > 0)

Z0

Real number or character input (Top/Bottom)


Real Number - It represents the distance from the shell element
reference plane to the bottom surface of the shell (Default = -0.5 *
Thick, Thick being the composite total thickness (real or blank)).
Character Input - See comment 18.

NSM

Nonstructural mass per unit area.


No default (Real)

SB

Allowable interlaminar shear stress (shear stress in the bonding


material). Disregarded if blank or 0.0.
No default (Real > 0.0)

FT

Failure theory code. If blank, no failure calculations are performed.


The following failure theory codes are supported:
HILL for Hill theory,
HOFF for Hoffman theory,
TSAI for Tsai-Wu theory,
STRN for Maximum Strain Theory.
See comments 14 through 16.
Default = no failure calculations are performed (HILL, HOFF, TSAI, or
STRN)

TREF

Reference (stress free) temperature. See comment 1.


Default = 0.0 (Real)

GE

Damping coefficient. See comments 10 and 11.


Default = 0.0 (Real)

1778 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

LAM

Laminate option. If blank, all plies must be specified and all stiffness
terms are developed. The following options are supported:
MEM: All plies must be specified, but only membrane terms MID1 are
developed. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
BEND: All plies must be specified, but only bending terms MID2 are
developed. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
SMEAR: All plies must be specified, stacking sequence is ignored, and
MID1 is set equal to MID2 on the derived equivalent PSHELL, while
MID3, MID4, TS/T, and 12I/T**3 are set to zero. Prescribed Z0 is
ignored (assumed to be: -0.5* Thick).
SMEARZ0: All plies must be specified, stacking sequence is ignored.
While the laminate is still considered to be made of homogenized
(smeared) material, the effect of offset Z0 is taken into account.
Hence, if Z0 is not equal to -0.5*Thick, the equivalent PSHELL will
include MID1, MID2 and MID4. MID3 is still set to zero, that is no
transverse shear deformation is considered.
SMCORE: All plies must be specified. The last ply specifies core
properties and the previous plies specify face sheet properties. The
face sheet properties are calculated without regard for stacking
sequence; half of the total face sheet thickness is then placed on top
of the core, and half is placed on the bottom, to produce a symmetric
laminate. Stiffness of the core is ignored while its density is included in
inertia calculations. Prescribed Z0 is ignored (assumed to be: -0.5*
Thick).
SYMEM: Only plies on the bottom half of the composite lay-up needs to
be specified. These plies are automatically symmetrically reflected to
the top half of the composite and given consecutive numbers from
bottom to top. Only membrane terms are developed for the full
laminate. Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
SYBEND: Only plies on the bottom half of the composite lay-up needs
to be specified. These plies are automatically symmetrically reflected
to the top half of the composite and given consecutive numbers from
bottom to top. Only bending terms are developed for the full laminate.
Prescribed Z0 is ignored (assumed to be: -0.5* Thick).
SYSMEAR: Only plies on the bottom half of the composite lay-up needs
to be specified. These plies are automatically symmetrically reflected
to the top half of the composite and given consecutive numbers from
bottom to top. Stacking sequence is ignored, and MID1 is set equal to
MID2 on the derived equivalent PSHELL, while MID3, MID4, TS/T and
12I/T**3 are set to zero. Prescribed Z0 is ignored (assumed to be: 0.5* Thick).

Altair Engineering

OptiStruct 13.0 Reference Guide 1779


Proprietary Information of Altair Engineering

Field

Contents
Default = blank, that is all plies must be specified (SYM, MEM, BEND,
SMEAR, SMCORE, SYMEM, SYBEND or SYSMEAR)

GPLYID#

Global Ply identification number, See comment 12.


No default (Integer > 0)

MID#

Material IDs of individual plies. The plies are identified by consecutively


numbering them from 1 at the bottom layer. The MIDs must refer to
MAT1, MAT2, MAT4, MAT5, or MAT8 bulk data entries. If MID# is not
specified, default is the last defined MID#.
Default = last defined MID# (Integer > 0 or blank, except that MID1
must be specified)

T#

Thicknesses of individual plies. If T# is not specified, default is the last


defined T#.
Default = last defined T# (Real > 0.0 or blank, except that T1 must be
specified)

THETA#

Orientation angle, in degrees, of the longitudinal direction of each ply


relative to the x-axis of the material coordinate system associated with
a given element. If no material coordinate system is prescribed for the
element, the angle is measured relative to side 1-2 of this element.
Default = 0.0 (Real or blank)

SOUT#

Stress and failure index output request for individual plies. See
comments 2 and 3.
Default = NO (YES or NO)

DS

Design switch. If non-zero (1.0), the elements associated with this


PCOMP data are included in the topology design volume or space.
Default = blank (Real = 1.0 or blank)

Comments
1.

TREF specified on the PCOMPG entry overrides reference temperatures given for individual
ply materials. If TREF is not specified (blank) on the PCOMPG card, then all the ply
materials must have the same reference temperature.

2.

For SOUTi to take effect, CSTRESS must be requested in the I/O options section of the
input deck. Individual ply results will be available in addition to shell stresses and strains

1780 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

based on the homogenized composite properties.


3.

An additional piece of information available with ply results is "failure index for the
element", which is the maximum of failure indices for individual plies in this element. Note
that only the plies with SOUTi set to YES are considered in the evaluation of this
maximum.

4.

If all plies specify zero transverse shear coefficients (G1Z, G2Z on MAT8 card, isotropic G
for MAT1, not available for MAT2), the in-plane shear modulus will be used to determine
transverse shear stiffness of the composite.
Note: If just one layer has a nonzero value specified for
transverse shear modulus, this substitution is not
being performed, and user-specified values are being
used for all plies.

5.

The signs given to stress limits for compression and tension (ST, SC, for MAT1; Xt, Xc,
and so on for MAT8) are of no relevance. Absolute values are taken and used in the
appropriate context to calculate failure indices.

6.
bottom and top surfaces of the shell are produced.
Note: These shell stresses are calculated using
homogenized shell properties, and should be
interpreted with caution.
7.
This is because the membrane-bending coupling resulting from composite offset is not
included in the differential stiffness matrix. Hence, the preferred method of incorporating
offset in buckling analysis is the element offset ZOFFS.
8.

Element GRID thicknesses cannot be defined for elements that reference PCOMPG data.

9.

Plies are listed from the bottom surface upwards, in respect to the elements normal
direction. The image below shows the stacking sequence for a non-symmetrical
laminate.

10. GE given on the PCOMP entry will be used for the element, and the values supplied on
material entries for individual plies are ignored. You are responsible for supplying the
equivalent damping value on the PCOMPG entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1781


Proprietary Information of Altair Engineering

11. To obtain the damping coefficient GE, multiply the critical damping ratio C/C0 by 2.0.
12. The global ply identification number must be unique with respect to other plies in the
entry.
13. For convenience, element output for the SMEAR and SMCORE options includes both
homogenized shell stresses and individual ply stresses. However, because stacking
sequence is ignored in these options, individual ply stresses will only be valid in cases of
pure membrane deformation.
14. Note that Hills failure theory does not differentiate between compressive and tensile
strength. Hence, while different values of respective strength limits are accepted, it is
still recommended that Xt is set to be equal to Xc and Yt is set to be equal to Yc when
this criteria is used. Xt and Xc are allowable tensile and compressive stresses in the
principle x direction of the material. Yt and Yc are allowable tensile and compressive
stresses in the principle y direction of the material.
15. Failure index calculation according to Maximum Strain Theory is based on mechanical
component of strain only, not on total strain. This is because only the mechanical strain
contributes to actual damage of the respective ply (pure thermal expansion produces no
damaging effects).
16. According to the formula, some failure criteria (for example, Tsai-Wu and Hoffman) would
produce a negative ply failure, depending on the problem.
17. If PARAM, SRCOMPS, YES is added to the input file, strength ratios with respect to
designated failure theory are output for composite elements that have failure indices
requested.
18. The following two formats are permissible for the Z0 field:
Real Number:
It represents the distance from the shell element reference plane to the bottom surface
of the shell (Default = -0.5 * Thick, Thick being the composite total thickness (Real or
blank)).
Surface:
Top:
The shell reference plane, the plane defined by the grid points, and the top surface of the
shell are coplanar.
This makes the effective "Real" Z0 value equal to the composite total thickness (-1.0 *
Thick). See Figure 1.

1782 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1: Top option for Z0

Bottom:
The shell reference plane, the plane defined by the grid points, and the bottom surface of
the shell are coplanar.
This makes the effective "Real" Z0 value equal to 0. See Figure 2.

Figure 2: Bottom option for Z0

Automatic offset control is available in composite free-size and sizing optimization where
the specified offset values are automatically updated based on thickness changes.
19. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1783


Proprietary Information of Altair Engineering

PCOMPP
Bulk Data Entry
PCOMPP Composite Laminate Property for Ply-Based Composite Definition
Description
Defines the properties of a composite laminate material used in ply-based composite definition.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PC OMPP

PID

Z0

NSM

SB

FT

TREF

GE

(9)

(10)

Example

(1)

(2)

(3)

PC OMPP

-0.1

(4)

(5)

(6)

(7)

HILL

20

Field

Contents

PID

Unique composite property identification number.

(8)

(9)

(10)

No default (Integer > 0)


Z0

Real number or character input (Top/Bottom)


Real Number - It represents the distance from the shell element
reference plane to the bottom surface of the shell (Default = -0.5 *
Thick, Thick being the composite total thickness (Real or blank)).
Character Input - See comment 12.

NSM

Nonstructural mass per unit area.


No default (Real)

SB

Allowable interlaminar shear stress (shear stress in the bonding


material). Disregarded if blank or 0.0.
No default (Real > 0.0)

1784 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

FT

Failure theory code. If blank, no failure calculations are performed.


The following failure theory codes are supported:
HILL for Hill theory,
HOFF for Hoffman theory,
TSAI for Tsai-Wu theory,
STRN for Maximum Strain Theory.
See comment 10.
Default = no failure calculations are performed (HILL, HOFF, TSAI or
STRN).

TREF

Reference (stress free) temperature. See comment 2.


Default = 0.0 (Real)

GE

Damping coefficient. See comments 6 and 7.


Default = 0.0 (Real)

Comments
1.

The PCOMPP card is used in combination with the STACK and PLY cards to create
composite properties through the ply-based definition.

2.

TREF specified on the PCOMPP entry overrides reference temperatures given for individual
ply materials. If TREF is not specified (blank) on the PCOMPP card, then all the ply
materials must have the same reference temperature.

3.
bottom and top surfaces of the shell are produced.
Note: These shell stresses are calculated using
homogenized shell properties, and should be
interpreted with caution.
4.
correct. This is because the membrane-bending coupling resulting from composite offset
is not included in the differential stiffness matrix. Hence, the preferred method of
incorporating offset in buckling analysis is the element offset ZOFFS.
5.

Element GRID thicknesses cannot be defined for elements that reference PCOMPP data.

6.

GE given on the PCOMPP entry will be used for the element, and the values supplied on
material entries for individual plies are ignored. You are responsible for supplying the
equivalent damping value on the PCOMPP entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1785


Proprietary Information of Altair Engineering

7.

To obtain the damping coefficient GE, multiply the critical damping ratio C/C0 by 2.0.

8.

Note that Hills failure theory does not differentiate between compressive and tensile
strength. Hence, while different values of respective strength limits are accepted, it is
still recommended that Xt is set to be equal to Xc and Yt is set to be equal to Yc when
this criteria is used. Xt and Xc are allowable tensile and compressive stresses in the
principle x direction of the material. Yt and Yc are allowable tensile and compressive
stresses in the principle y direction of the material.

9.

Failure index calculation according to Maximum Strain Theory is based on mechanical


component of strain only, not on total strain. This is because only the mechanical strain
contributes to actual damage of the respective ply (pure thermal expansion produces no
damaging effects).

10. According to the formula, some failure criteria (for example, Tsai-Wu and Hoffman) would
produce a negative ply failure, depending on the problem.
11. If PARAM, SRCOMPS, YES is added to the input file, strength ratios with respect to
designated failure theory are output for composite elements that have failure indices
requested.
12. The following two formats are permissible for the Z0 field:
Real Number:
It represents the distance from the shell element reference plane to the bottom surface
of the shell (Default = -0.5 * Thick, Thick being the composite total thickness (Real or
blank)).
Surface:
Top:
The shell reference plane, the plane defined by the grid points, and the top surface of the
shell are coplanar.
This makes the effective "Real" Z0 value equal to the composite total thickness (-1.0 *
Thick). See Figure 1.

Figure 1: Top option for Z0

Bottom:
The shell reference plane, the plane defined by the grid points, and the bottom surface of

1786 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

the shell are coplanar.


This makes the effective "Real" Z0 value equal to 0. See Figure 2.

Figure 2: Bottom option for Z0

Automatic offset control is available in composite free-size and sizing optimization where
the specified offset values are automatically updated based on thickness changes.
13. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1787


Proprietary Information of Altair Engineering

PCOMPX
Bulk Data Entry
PCOMPX Optional Composite Laminate Property Extension for Geometric Nonlinear Analysis
Description
Defines additional composite laminate properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PC OMPX

PID

ISHELL

ISH3N

ISMSTR

DM

DN

ITHIC K

IPLAS

(7)

(8)

(9)

HM

HF

HR

(10)

Example

(1)

(2)

PC OMP

73

PC OMPX

(3)

(4)

(5)

(6)

(7)

(8)

(9)

120

0.2

0.0

YES

120

0.6

45.0

YES

73

24

Field

Contents

PID

Property ID of the associated PSHELL. See comment 1.

(10)

No default (Integer > 0)


ISHELL

Flag for CQUAD4 element formulation.


1 - Q4, visco-elastic hourglass modes orthogonal to deformation and rigid
modes (Belytschko)
2 - Q4, visco-elastic hourglass without orthogonality (Hallquist)
3 - Q4, elastic-plastic hourglass with orthogonality

1788 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
4 - Q4 with improved type 1 formulation (orthogonalization for warped
elements)
12 - QBAT or DKT18 shell formulation
24 - QEPH shell formulation
Default as defined by XSHLPRM (Integer)

ISH3N

Flag for CTRIA3 element formulation.


1 - Standard triangle (C0)
2 - Standard triangle (C0) with modification for large rotation
30 - DKT18
31 - DKT_S3
Default as defined by XSHLPRM (Integer)

ISMSTR

Flag for shell small strain formulation.


1 - Small strain from time = 0
2 - Full geometric non-linearity with optional small strain formulation
activation by time step XSTEP, TYPEi = SHELL, TSCi = CST
3 - Alternative small strain formulation from time = 0 (ISHELL =2 only).
4 - Full geometric non-linearity (Time step limit has no effect)
Default as defined by XSHLPRM (Integer)

HM

Shell membrane hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (Real, 0.0 < HM < 0.05)
Except ISHELL = 3: Default = 0.1 (Real)

HF

Shell out of plane hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (Real, 0.0 < HF < 0.05)

HR

Shell rotation hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (Real, 0.0 < HR < 0.05)
Except ISHELL = 3: Default = 0.1 (Real)

DM

Shell membrane damping (with MATX27, MATX36 only).


Default: See comment 7 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1789


Proprietary Information of Altair Engineering

Field

Contents

DN

Shell numerical damping (ISHELL = 12, 24; ISH3N = 30 only).


Default: See comment 8 (Real)

ITHICK

Flag for shell resultant stresses calculation.


CONST - Thickness is constant
VAR - Thickness change is taken into account
Default as defined by XSHLPRM (CONST or VAR)

IPLAS

Flag for shell plane stress plasticity (with MATX27 only).


RAD - Radial return
NEWT - Iterative projection with 3 Newton iterations
Default as defined by XSHLPRM (RAD or NEWT)

Comments
1.

The property identification number must be that of an existing PCOMP, PCOMPG, or


PCOMPP bulk data entry. Only one PCOMPX property extension can be associated with a
particular PCOMP, PCOMPG, or PCOMPP.

2.

PCOMPX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

Q4: Original 4 node OptiStruct shell with hourglass perturbation stabilization.


QEPH: Formulation with physical hourglass stabilization for general use.
QBAT: Modified BATOZ Q4 24 shell with 4 Gauss integration points and reduced
integration for in-plane shear. No hourglass control is needed for this shell.
DKT18: BATOZ DKT18 thin shell with 3 Hammer integration points.

4.

If the small strain option (ISMSTR) is set to 1 or 3, engineering strain and stress are
used; otherwise they are true strain and stress.

5.

For ITHICK = VAR it is recommended to use IPLAS = NEWT.

6.

If ITHICK = VAR or IPLAS = NEWT, the small strain option is automatically deactivated.

7.

Defaults for DM:


Material

Element type

ISHELL/ISH3N

Default

MATX27

except QEPH, QBAT

except 12, 24

5%

QEPH

24

1.5%

QBAT

12

0%

1790 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

8.

9.

Material

Element type

ISHELL/ISH3N

Default

MATX36

except QEPH

except 24

0%

QEPH

24

1.5%

Defaults for DN:


Element
type

ISHELL/
ISH3N

Default

Usage

QBAT

12

0.1%

All stress terms, except


transverse shear

QEPH

24

1.5%

Hourglass stress

DKT18

12/30

0.01%

Membrane stress only

This card is represented as extension to a PCOMP, PCOMPG, and PCOMPP property in


HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1791


Proprietary Information of Altair Engineering

PCONT
Bulk Data Entry
PCONT Contact Property
Description
Defines properties of CONTACT interface.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PC ONT

PID

GPAD

STIFF

MU1

MU2

C LEARANC E

(9)

(10)

FRIC ESL

Examples

(1)

(2)

PC ONT

34

(3)

(4)

(5)

(6)

0.3

0.25

(7)

(8)

(9)

(10)

Enforced stick condition:


PC ONT

34

STIC K

Field

Contents

PID

Property identification number.


No default (Integer > 0)

GPAD

Padding of the interface to account for additional layers, such as shell


thickness. This value is subtracted from the contact gap opening as
calculated from the location of nodes. See comment 1.
Default = THICK (Real, NONE or THICK)

1792 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

STIFF

Relative stiffness of contact interface. See comment 2.


Default = AUTO (AUTO, SOFT, HARD or Real > 0.0)

MU1

Coefficient of static friction ( s). See comments 3 and 4.


Default = 0.0 (Real > 0.0 or STICK or FREEZE)

MU2

Coefficient of kinetic friction ( k). (Ignored in linear analysis).


Default = MU1 (0.0 < Real < MU1)

CLEARANCE

Prescribed initial gap opening between master and slave, irrespective of


the actual distance between the nodes. See comment 11.
Default = not prescribed. (Real or blank).

FRICESL

Frictional elastic slip distance of sliding up to which the frictional


transverse force increases linearly with slip distance. Specified in
physical distance units (similar to U0 and GPAD). See Comment 7.

Non-zero value or blank activates respective friction model based


on Elastic Slip Distance.

Zero value activates friction model based on fixed transverse


stiffness KT.

Default = AUTO (Real > 0.0 or AUTO)


Comments
1.

The initial contact gap opening is calculated automatically based on the relative location
of slave and master nodes (in the original, undeformed mesh). To account for additional
material layers covering master and slave objects, the GPAD entry can be used. GPAD
option THICK automatically accounts for shell thickness on both sides of the contact
interface (this also includes the effects of shell element offset ZOFFS or composite offset
Z0).

2.

Option STIFF=AUTO determines the value of normal stiffness for each contact element
using the stiffness of surrounding elements. Additional options SOFT and HARD create
respectively softer or harder penalties. SOFT can be used in cases of convergence
difficulties and HARD can be used if undesirable penetration is detected in the solution.

3.

Prescribing MU1=STICK is interpreted in OptiStruct as an enforced stick condition such


contact interfaces will not enter the sliding phase. Of course, the enforced stick only
applies to contacts that are closed. Note that, in order to effectively enforce the stick
condition, frictional offset may need to be turned off (See comment 8).

4.

Prescribing MU1=FREEZE enforces zero relative motion on the contact surface the
contact gap opening remains fixed at the original value and the sliding distance is zero.
Also, rotations at the slave node are matched to the rotations of the master patch. The

Altair Engineering

OptiStruct 13.0 Reference Guide 1793


Proprietary Information of Altair Engineering

FREEZE condition applies to all respective contact elements, no matter whether open or
closed (hence, GPAD is of no relevance in this case). Also, this condition is effective
irrespective of the frictional offset setting.
If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.
5.

The CONTACT element force-displacement behavior is different in linear and nonlinear


analysis (see Nonlinear Gap and CONTACT Analysis for more information on nonlinear
solutions). In linear analysis, the contact stiffness is constant and depends on the initial
contact gap opening U0 as calculated from the positions of Slave and Master (and
considering padding GPAD). Note that for open contact elements, a very small stiffness
value of KB =10-14 *STIFF is used to avoid numerical singularities.

C ONTAC T element force deflection curve for linear analysis

The CONTACT force displacement behavior in nonlinear analysis is illustrated in the figure
below. While the contact is open, its normal stiffness is essentially zero (a small value of
KB =10-14 *STIFF is used to avoid singularities). When the contact element closes, the
stiffness becomes STIFF.

1794 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C ONTAC T element force deflection curve for nonlinear analysis

6.

When contact is open, there is no transverse stiffness. When the contact is closed,
friction is activated and the contact has stiffness KT=mu1*STIFF in the transverse
direction (KT=0.1*STIFF in case of STICK). This acts as a linear spring in linear solution
sequences. For nonlinear solution sequences, frictional force increases with sliding
distance in proportion to KT until it reaches static friction force MU1 * Fx, Fx being the
normal force in the contact element. With further transverse deformation, friction
becomes kinetic and the friction force is MU2 * Fx. See the figure below for a onedimensional illustration.

C ONTAC T element frictional behavior in nonlinear analysis

Note that the nonlinear contact element's force-displacement behavior may produce
negative contributions to the compliance of the structure. As an example, when slave
and master bodies have initial overlap and the contact releases elastic energy during the
solution.
7.

Effective in Release 12.0, two models of friction are available in nonlinear analysis:
(a) Model based on fixed slope KT (previously existing),

Altair Engineering

OptiStruct 13.0 Reference Guide 1795


Proprietary Information of Altair Engineering

(b) Model based on Elastic Slip Distance FRICESL (introduced in v12.0 and current
default).
This latter model typically shows better performance in solution of frictional problems
thanks to more stable handling of transitions from stick to slip. Key differences between
the two available models are illustrated in the figure below (F 1 and F 2 represent two
different values of normal force F x ):

C omparison of the two available friction models for contact elements.

Model (a), based on fixed stiffness KT, is relatively simple, yet has certain drawback in
modeling nonlinear friction. Namely, in Coulomb friction the frictional resistance depends
upon normal force. Using fixed KT will predict different range of stick/slip boundary for
different normal forces, and thus may qualify the same configuration as stick or slip,
depending on normal force.
Model (b), based on Elastic Slip Distance, provides unique identification of stick or slip
and generally performs better in solution of problems with friction. This model does
require prescribing elastic slip distance FRICESL for contact interfaces this value is
determined automatically as 0.5% of typical element size on all Master contact
surfaces.
The model (b), which is currently the default, is recommended for solution of nonlinear
problems with friction. For backwards compatibility, the model based on fixed KT can be
activated by prescribing FRICESL=0 on PCONT or CONTPRM card.
8.

The model of friction in OptiStruct is relatively simple. The frictional force is always
directed back to the point where the slave and master first came into contact (changed
status from open to closed). Its location is estimated using proportional interpolation
between the current position and the last converged solution before penetration.
OptiStruct CONTACT should not be used for modeling frictional problems with complex
deformation paths and changing sliding directions.

9.

The presence of friction can introduce moment loadings and counter-intuitive results into
the problem by way of frictional offset. The reason for this is that, for contact elements
with non-zero length (distance between slave node and master segment), the actual
location of the contact interface is presumed to be in the middle of the contact elements
length (see figure below).

1796 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C ONTAC T presumed contact surface

The frictional forces act along this contact surface. Transferring these forces to the
slave and master objects requires an offset operation that produces both forces and
moments at slave and master. Similarly, the sliding distance at the contact interface is a
result of nodal displacements and rotations of the slave node and master segment (see
figure below).

C ONTAC T sliding with friction

Master segments, which consist of several nodes, can effectively resist these offset
forces and moments. However, for slave bodies that do not support moments (nodes of
solid elements, for example), this offset may render friction ineffective because the free
rotations at slave nodes offer no effective resistance to friction. With the stick condition
formally satisfied, for example, slave and master can move relative to each other (see
figure below).

Altair Engineering

OptiStruct 13.0 Reference Guide 1797


Proprietary Information of Altair Engineering

C ONTAC T stick (zero sliding distance)

In practice, for contact interfaces that are initially open, AUTOSPC will effectively fix
respective unsupported rotations. However, for contacts that are initially closed (for
example, pre-penetrating contact with MORIENT=NORMAL) the frictional terms will
prevent AUTOSPC from being effective. Hence, respective SPC on rotations need to be
applied manually to respective slave nodes.
Effective in the Release 12.0, to avoid such counter-intuitive behavior, the frictional
offset operation is by default turned off if the model involves friction or stick and contains
at least one nonlinear subcase (of NLSTAT type). (Note that for consistency, this affects
both linear and nonlinear contact elements.) This produces more intuitive results with
friction. However, it may violate the rigid body balance of the body.
Note: FREEZE condition is enforced using a special
formulation where the above caveat does not apply
and the offset operation is always applied.
The above default setting can be changed via the GAPOFFS command on the GAPPRM
card.
10. The presence of friction, due to its strongly nonlinear, non-conservative nature, may
cause difficulties in nonlinear convergence, especially when sliding is present. If frictional
resistance is essential to the solution of the problem and convergence problems are
encountered, enforcing the stick condition (by prescribing KT>0 and MU=0) may be a
viable solution that will often result in better convergence than with Coulomb friction.
Note however, that this only applies to problems in which minimal sliding is expected. In
the case of larger sliding motions, the stick condition may lead to divergence through a
"tumbling" mode.
11. Prescribing CLEARANCE overrides the default contact behavior of calculating initial gap
opening from the actual distance between Slave and Master. CLEARANCE now becomes
the distance that Slave and Master have to move towards each other in order to close
the contact. Negative value of CLEARANCE means that the bodies have initial prepenetration.

1798 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Warning: When prescribing CLEARANCE, it is important to


correctly restrict the contact zones and pick
search distance SRCHDIS so that only desired
Slave-Master pairs are involved. With
prescribed CLEARANCE, all contact elements
created on a given interface, even those
where Slaves are geometrically distant from
the respective Master surface, will be
considered to be at prescribed initial gap and
participate in resolving the contact condition.

Note: CLEARANCE cannot be prescribed together with (nonzero) GPAD. Blank GPAD field in presence of
CLEARANCE is interpreted as NONE.
12. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1799


Proprietary Information of Altair Engineering

PCONTHT
Bulk Data Entry
PCONTHT Define Conductivity for Contact in Heat Transfer Analysis
Description
Defines conductivity for CONTACT elements in heat transfer analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

PC ONTHT

PID

KC

KO

TPID

TC ID

(8)

(9)

(10)

Examples

(1)

(2)

(3)

PC ONTHT

1E6

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Contact with automatic determination of KC:


PC ONTHT

AUTO

Minimum data required to prescribe pressure based conductivity for contact:


PC ONTHT

10

Clearance and pressure based conductivity for contact (see comments 3 and 4):
PC ONTHT

1E6

10

20

Field

Contents

PID

Property identification number. Must match with a PID of a PCONT bulk


data entry. See comment 1.

1800 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
No default (Integer > 0)

KC

Conductivity for the closed contact. See comment 2.

KO

Conductivity for the open contact. See comment 2.


Default = 10-14 * KC (Real > 0.0) This default is also set when KO =0.

TPID

Identification number of a TABLED# entry. This table specifies


conductivity based on contact pressure. See comments 2, 3, and 4.
Default = 0 (Integer > 0)

TCID

Identification number of a TABLED# entry. This table specifies


conductivity based on contact clearance. See comments 2, 3, and 4.
Default = 0 (Integer > 0)

Comments
1.

PCONTHT provides heat transfer conductivity for CONTACT element. PCONTHT must
match PID with an existing PCONT.

2.

KC and KO represent conductivity values for closed and open contacts. Theoretically,
while higher conductivity values enforce a perfect conductor, excessively high values may
cause poor conditioning of the conductivity matrix. If any such symptoms are observed,
it may be beneficial to reduce the value of conductivity, or use conductivity based
contact clearance and pressure.
To facilitate reasonable values for KC, automatic calculation is supported, specifically:
Option KC=AUTO determines the value of KC for each contact element using the
conductivity of surrounding elements.

3.

TPID points to a TABLED# entry that specifies conductivity based on contact pressure.
TPID overrides KC.

4.

TCID points to a TABLED# entry that specifies contact based on contact clearance. TCID
overrides KO. TPID can be specified together with TCID. When TPID is specified together
with TCID, conductivity is determined from the table with TCID for open contact, and
from the table with TPID for closed contact.

5.

PCONTHT is not supported for surface-to-surface contact (DISCRET=S2S on CONTACT/


TIE).

6.

Thermal-structural analysis problems involving contact are fully coupled since contact/gap
status changes thermal conductivity. Refer to Contact-based Thermal Analysis in the
Users Guide for more information.

7.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1801


Proprietary Information of Altair Engineering

PCONTX
Bulk Data Entry
PCONTX Extended CONTACT Property for Geometric Nonlinear Analysis
Description
Defines properties of a CONTACT interface for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

PC ONTX

PID

STFAC

FRIC

GAP

IDEL

INAC TI

TSTART

TEND

ISYM

IEDGE

FANG

IGAP

ISTF

STIF1

VISS

VISF

BMULT

IBC

MULTIMP

IFRIC

IFORM

IFILT

FFAC

C1

C2

C3

C4

C5

(8)

(9)

(10)

C TYPE

STMIN

STMAX

C6

Example

(1)

(2)

PC ONT

34

PC ONTX

34

(3)

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property identification number of the associated PCONT.

(9)

(10)

No default (Integer > 0)

1802 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

STFAC

Interface stiffness scale factor.


Default as defined by CONTPRM (Real > 0)

FRIC

Coulomb friction.
Default as defined by CONTPRM (Real > 0)

GAP

Gap for impact activation (See comments 4 and 6).


Default as defined by CONTPRM (Real > 0)

IDEL

Flag for node and segment deletion.


Default as defined by CONTPRM (Integer = 0, , 2)
0 - No deletion.
1 - When all the elements (shells, solids) associated to one segment are
deleted, the segment is removed from the master side of the interface.
Additionally, non-connected nodes are removed from the slave side of
the interface.
2 - When a shell or a solid element is deleted, the corresponding
segment is removed from the master side of the interface. Additionally,
non-connected nodes are removed from the slave side of the interface.

INACTI

Flag for handling of initial penetrations (See comment 8).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - No action.
1 - Deactivation of stiffness on nodes.
2 - Deactivation of stiffness on elements.
3 - Change slave node coordinates to avoid small initial penetrations.
4 - Change master node coordinates to avoid small initial penetrations.
5 - Gap is variable with time but initial gap is slightly de-penetrated as
follows:
gap0 = gap - P0 0.05*(gap - P0 )
Valid in explicit analysis: 0, 1, 2, 3 and 5.
Valid in implicit analysis: 0, 3 and 4.
Invalid entries are ignored.

CTYPE

Implicit contact type.


Default = TYPE7 (Character = TYPE5, TYPE7)

Altair Engineering

OptiStruct 13.0 Reference Guide 1803


Proprietary Information of Altair Engineering

Field

Contents

TSTART

Start time
Default = 0.0 (Real > 0)

TEND

Time for temporary deactivation.


Default = 1030 (Real > 0)

The following entries are relevant for explicit analysis only.


ISYM

Flag for symmetric contact.


Default as defined by CONTPRM (Character = SYM, UNSYM)
SYM Symmetric contact.
UNSYM Master-slave contact.
If SSID defines a grid set, the contact is always a master-slave contact.

IEDGE

Flag for edge generation from slave and master surfaces.


Default as defined by CONTPRM (Character = NO, ALL, BORD, FEAT)
NO No edge generation.
All All segment edges are included.
BORD External border of slave and master surface is used.
FEAT External border as well as features defined by FANG are used.

FANG

Feature angle for edge generation (Only with IEDGE = FEAT).


Default as defined by CONTPRM (Real > 0)

IGAP

Flag for gap definition.


Default as defined by CONTPRM (Character = CONST, VAR)
CONST - Gap is constant and equal to GAP (See comment 6).
VAR - Gap is variable (in space, not in time) according to the
characteristics of the impacting surfaces and nodes (See comment 7).

ISTF

Flag for stiffness definition (See comment 5).


Default as defined by CONTPRM (Integer = 0, , 5)
0 - The stiffness is computed according to the master side
characteristics.
1 - STIF1 is used as interface stiffness.
2, 3, 4 and 5 - The interface stiffness is computed from both master and
slave characteristics.

1804 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

STIF1

Interface stiffness (Only with ISTF = 1)


Default = 0.0 (Real > 0)

STMIN

Minimum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

STMAX

Maximum stiffness (Only with ISTF > 1).


Default as defined by CONTPRM (Real > 0)

IBC

Flag for deactivation of boundary conditions at impact applied to the


slave grid set.
Default as defined by CONTPRM (Character = X, Y, Z, XY, XZ, YZ, XYZ)

MULTIMP

Maximum average number of impacted master segments per slave node


Default = 4 for SMP; 12 for SPMD (Integer > 0)

VISS

Critical damping coefficient on interface stiffness.


Default as defined by CONTPRM (Real > 0)

VISF

Critical damping coefficient on interface friction.


Default as defined by CONTPRM (Real > 0)

BMULT

Sorting factor. Can be used to speed up the sorting algorithm. Is


machine-dependent.
Default as defined by CONTPRM (Real > 0)

IFRIC

Friction formulation flag (See comment 8).


Default as defined by CONTPRM (Character = COUL, GEN, DARM, REN)
COUL - Static Coulomb friction law.
GEN - Generalized viscous friction law.
DARM - Darmstad friction law.
REN - Renard friction law.

IFORM

Type of friction penalty formulation (See comment 9).


Default as defined by CONTPRM (Character = VISC, STIFF)
VISC - Viscous (total) formulation.
STIFF - Stiffness (incremental) formulation.

Altair Engineering

OptiStruct 13.0 Reference Guide 1805


Proprietary Information of Altair Engineering

Field

Contents

IFILT

Friction filtering flag (See comment 10).


Default as defined by CONTPRM (Character = NO, SIMP, PER, CUTF)
NO - No filter is used.
SIMP - Simple numerical filter.
PER - Standard -3dB filter with filtering period.
CUTF - Standard -3dB filter with cutting frequency.

FFAC

Friction filtering factor.


Default as defined by CONTPRM (Real = 0.0 < FFAC < 1.0)

C1, C2, C3, Coefficients to define variable friction coefficient in IFRIC = GEN, DARM,
C4, C5, C6 REN.
Default as defined by CONTPRM (Real > 0)
Comments
1.

The property identification number must be that of an existing PCONT bulk data entry.
Only one PCONTX property extension can be associated with a particular PCONT.

2.

PCONTX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

If FRIC is not explicitly defined on the PCONTX/PCNTX# entries, the MU1 value on the
CONTACT or PCONT entry is used for FRIC in the /INTER entries for Geometric Nonlinear
Analysis. Otherwise, FRIC on PCONTX/PCNTX# overwrites the MU1 value on CONTACT/
PCONT.

4.

In implicit analysis, different contact formulations are used for contact where slave and
master set do not overlap and where they overlap (self-contact).
In the case of self-contact, the gap cannot be zero and a constant gap is used. For
small initial gaps, the convergence will be more stable and faster if GAP is larger than the
initial gap.
In implicit analysis, sometimes a stiffness with scaling factor reduction (for example,
STFAC = 0.01) or reduction in impacted thickness (if rigid one) might reduce unbalanced
forces and improve convergence, particularly in shell structures under bending where the
effective stiffness is much lower than membrane stiffness; but it should be noted that too
low of a value could also lead to divergence.

5.
and/or the slave segment stiffness Ks.
The master stiffness is computed from Km = STFAC * B * S * S/V for solids, Km = 0.5 *
STFAC * E * t for shells.
The slave stiffness is an equivalent nodal stiffness computed as Ks = STFAC * B * V- 3 for
solids, Ks = 0.5 * STFAC * E * t for shells.

1806 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

In these equations, B is the Bulk Modulus, S is the segment area, and V is the volume of a
solid. There is no limitation to the value of stiffness factor (but a value larger than 1.0
can reduce the initial time step).
The interface stiffness is then K = max (STMIN, min (STMAX, K1)) with
ISTF = 0, K1 = Km
ISTF = 2, K1 = 0.5 * (Km + Ks)
ISTF = 3, K1 = max (Km, Ks)
ISTF = 4, K1 = min (Km, Ks)
ISTF = 5, K1 = Km * Ks / (Km + Ks)
6.

The default for the constant gap (IGAP = CONST) is the minimum of
t, average thickness of the master shell elements;
l/10, l average side length of the master solid elements;
lmin/2, lmin smallest side length of all master segments (shell or solid).

7.

The variable gap (IGAP = VAR) is computed as gs + gm


with:
gm - master element gap with
gm = t/2, t: thickness of the master element for shell elements.
gm = 0 for solid elements.
gs - slave node gap:
gs = 0 if the slave node is not connected to any element or is only connected to solid or
spring elements.
gs = t/2, t - largest thickness of the shell elements connected to the slave node.

If the slave node is connected to multiple shells and/or beams or trusses, the largest
computed slave gap is used.
8.

INACTI = 3, 4 are only recommended for small initial penetrations and should be used with
caution because:
the coordinate change is irreversible.
it may create other initial penetrations if several surface layers are defined in the
interfaces.
it may create initial energy if the node belongs to a spring element.
INACTI = 5 works as follows:

Altair Engineering

OptiStruct 13.0 Reference Guide 1807


Proprietary Information of Altair Engineering

9.

IFRIC defines the friction model.


IFRIC = COUL Coulomb friction with F T < FRIC * F N .
For IFRIC > 0 the friction coefficient is set by a function (m = m (p, V)), where p is the
pressure of the normal force on the master segment and V is the tangential velocity of
the slave node.
The following formulations are available:
IFRIC = 1 - Generalized viscous friction law
m = FRIC + C1 * p + C2 * V + C3 * p * v + C4 * p2 + C5 * v2
IFRIC = 2 - Darmstad law
m = C1 e(C 2 V ) p2 + C3 e(C 4 V ) p + C5 e(C 6 V )
IFRIC = 3 - Renard law

0 < V < C5

C5 < V < C6

C6 < V

where:

1808 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

The first critical velocity Vcr1


second critical velocity Vcr2 (C5 < C6).
The static friction coefficient C1 and the dynamic friction coefficient C2, must be lower
than the maximum friction C3 (C1 < C3) and C2 < C3).
The minimum friction coefficient C4, must be lower than the static friction coefficient
C1 and the dynamic friction coefficient C2 (C4 < C1 and C4 < C2).
10. IFORM selects two types of contact friction penalty formulation.
The viscous (total) formulation (IFORM = VISC) computes an adhesive force as
F adh

F T = min (F N , F adh)
The stiffness (incremental) formulation (IFORM = STIFF) computes an adhesive force as
F adh = F T old + F T
F T = K * VT * dt
F T new = min (F N , F adh)
11.
the tangential friction forces are smoothed using a filter:
F T = * F'T + (1 - ) * F'T - 1
where,
F T - Tangential force
F'T - Tangential force at time t
F'T - 1 - Tangential force at time t-1
- filtering coefficient
IFILT = SIMP = FFAC
IFILT = PER = 2 dt/FFAC, where dt/T = FFAC, T is the filtering period
IFILT = CUTF = 2

* FFAC * dt, where FFAC is the cutting frequency

12. This card is represented as an extension to a PCONT property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1809


Proprietary Information of Altair Engineering

PCONV
Bulk Data Entry
PCONV Free Convection Property Definition
Description
Defines a free convection boundary condition properties.
Format
(1)

(2)

(3)

(4)

(5)

PC ONV

PC ONID

MID

FORM

EXPF

(6)

(7)

(8)

Field

Contents

PCONID

Convection property identification number of a PCONV card.

(9)

(10)

No default (Integer > 0)


MID

Material property identification number of MAT4 card.


No default (Integer > 0)

FORM

Types of formula used for free convection.


Default = 0, Integer 0, 1, 10, 11, 20, 21

EXPF

Free convection exponent.


For FORM = 0, 10, and 20, EXPF = 0.0
For FORM = 1, 11, and 21, EXPF = 1.0

Comments
1.

Every CONV card must refer a PCONV card.

2.

Heat transfer coefficient (H) is specified on MAT4 card with MID.

3.

FORM specifies the convection formula type.


If FORM = 0, 10, 20,
q = H * (T - TAMB)E XP F * (T - TAMB)
If FORM = 1, 11, 21
q = H * (T E XP F - TAMBE XP F ))
where, T is grid temperature and TAMB is the ambient temperature.

1810 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

EXPF is the free convection temperature exponent.


If FORM = 0, 10, 20, EXPF = 0.0 for linear convection.
If FORM = 1, 11, 21, EXPF = 1.0 for linear convection.
Therefore, linear convection formula is:
q = H * (T-TAMB)

5.

This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1811


Proprietary Information of Altair Engineering

PDAMP
Bulk Data Entry
PDAMP Scalar Damper Property
Description
Specifies the damping of a scalar damper element using defined CDAMP1 or CDAMP3 entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PDAMP

PID1

B1

PID2

B2

PID3

B3

PID4

B4

(10)

Example

(1)

(2)

(3)

(4)

(5)

PDAMP

14

2.3

6.1

Field

Contents

PID#

Property identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


B#

Force per unit velocity.


No default (Real)

Comments
1.

Damping values are defined directly on the CDAMP2 entry and therefore do not require a
PDAMP entry.

2.

A structural viscous damper, CVISC, may also be used for geometric grid points.

3.

Up to four damping properties may be defined on a single entry.

4.

This card is represented as a property in HyperMesh.

1812 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PEAKOUT
Bulk Data Entry
PEAKOUT Peak Identification Criteria
Description
Defines criteria used for the automatic identification of loading frequencies at which result
peaks occur. Other result output may then be requested at these peak loading frequencies.
This feature is only supported for frequency response solution sequences.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PEAKOUT

SID

NPEAK

NEAR

FAR

LFREQ

HFREQ

RTYPE

PSC ALE

GRIDC

GID1

C ID1

C UTOFF1

GID2

C ID2

C UTOFF2

GID3

C ID3

C UTOFF3

...

...

...

...

...

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PEAKOUT

396

0.5

100.0

0.0

200.0

DISP

DB

GRIDC

65

11

66

10

67

11

68

11

Field

Contents

SID

Set identification number.

(10)

No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1813


Proprietary Information of Altair Engineering

Field

Contents

NPEAK

Desired number of peaks. See comment 2.


Default = 5 (Integer > 0)

NEAR

Minimum allowed distance between two peaks. If two peaks are closer
than this value, the loading frequency of the lower peak will be ignored.
See comment 2.
Default = 0.0 (Real > 0.0)

FAR

Maximum allowed distance between two peaks. Additional peaks will be


selected (in addition to NPEAK) if the distance between the peaks is
greater than this value. See comment 2.
Default = largest applied loading frequency (Real > 0.0)

LFREQ

Starting loading frequency for peak identification. See comment 2.


Default = 0.0 (Real > 0.0)

HFREQ

Ending loading frequency for peak identification. See comment 2.


Default = largest applied loading frequency (Real > 0.0)

RTYPE

Result type for peak identification for the structural domain.


The result for a structural degree of freedom can be displacement (DISP),
velocity (VELO), or acceleration (ACCE).
Default = DISP (DISP, VELO or ACCE)

PSCALE

Pressure scaling method for peak identification for the fluid domain.
The result for a fluid grid can be the scale of pressure, decibels (DB) or Aweighted decibels (DBA). See comment 3 for decibel calculations and
reference pressure settings. For DBA, standard A-weighting is used.
Default = DBA (DB, DBA or NONE)

GRIDC

Flag indicating that a degree-of-freedom list for peak identification is to


follow.

GID#

Grid identification number.


No default (Integer > 0)

1814 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

CID#

Component identification number.


No default (1 < Integer < 6)

CUTOFF#

The cutoff value can be a real value or an integer value. See comment 2.
If the entry is a real value, then this is the value of the cutoff (in the
same unit specified by RTYPE and PSCALE).
If the entry is an integer value, then this is the identification number of a
TABLED1, TABLED2, TABLED3, or TABLED4 entry defining the cutoff as a
function of frequency (in the same unit specified by RTYPE and PSCALE).
Default = 0.0 (Real or Integer > 0)

Comments
1.

There can be multiple PEAKOUT cards with the same SETID.

2.

The following example shows how the different criteria work in identifying peaks.

Figure 1: Plot of the Acoustic Response vs. Frequency

Altair Engineering

OptiStruct 13.0 Reference Guide 1815


Proprietary Information of Altair Engineering

Figure 1 shows a plot of the Acoustic Response versus frequency for a chosen degree-offreedom. The total frequency range can be reduced to the frequency range of interest by
defining LFREQ and HFREQ. The search area can be further reduced by defining CUTOFF
such that low magnitude peaks can be ignored. In the remaining region, 5 peaks (P1, P2,
P3, P4, and P5) can easily be identified. Should NPEAK be set to 4, the resulting
frequency set would consist of the frequencies corresponding to the peaks P4, P5, P1,
and P3, with P5 being omitted.
In order to ensure that peaks are neither too far apart nor too close together, the FAR
and NEAR criteria, respectively, may be used.
In the above example, should a value of 50HZ be defined for FAR, P4 would be selected in
addition to the other peaks because D2 (~54 Hz) is greater than 50Hz, and so an
additional peak is required to satisfy the FAR criterion.
Similarly, should a value of 15Hz be defined for NEAR, then P2 will be omitted, as D1 (~11
Hz) is less than 15Hz.
3.

The dB value is calculated using 20 * log10 (P/P0), where P0 is the reference pressure.
The reference pressure is dependent on the units specified on the UNITS input data. If
the units are SI, the value is set as 2.0E-5 Pa. If they are CGS, it is set as 2.0E-4 barye.
If they are MPa, it is set as 2.0E-11 MPa. If they are BG or EE, then it is set as 4.17E-7
lbf/ft 2. If no UNITS data is present, the default value is 2.0E-11 MPa.

4.

If you wish to include interior points of a superelement (in a CMS model) for the purposes
of peak identification using the PEAKOUT bulk data entry, the SEINTPNT entry can be
used in the subcase information section to convert the interior grid points to exterior grid
points (since points referenced by PEAKOUT should be exterior points only).

1816 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PELAS
Bulk Data Entry
PELAS Scalar Elastic Property
Description
Used to define the stiffness and stress coefficient of a scalar elastic element (spring) by
means of the CELAS1 or CELAS3 entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PELAS

PID

GE

PID

GE

(10)

Example

(1)

(2)

(3)

PELAS

4.29

(4)

(5)

(6)

(7)

7.92

27

2.17

Field

Contents

PID

Unique scalar elastic property identification number.

(8)

(9)

(10)

No default (Integer > 0)


K

Elastic property value.


No default (Real)

GE

Damping Coefficient. See comments 3 and 4.


Default = 0.0 (Real)

Stress coefficient.
Default = 0.0 (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1817


Proprietary Information of Altair Engineering

Comments
1.

Be careful using negative spring values.

2.

One or two elastic spring properties may be defined on a single entry.

3.

To obtain the damping coefficient GE, multiply the critical damping ratio, C/C0, by 2.

4.

If PARAM, W4 is not specified, GE is ignored in transient analysis.

5.

The element force of a spring is calculated from the equation:

F = k * (u1 u2)
Where, k is the stiffness coefficient for the scalar element and u1 is the displacement of
the first degree-of-freedom listed on the CELAS entry. Element stresses are calculated
from the equation: s = S * F, where, S is the stress coefficient as defined above.
6.

This card is represented as a property in HyperMesh.

1818 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PELAST
Bulk Data Entry
PELAST Frequency-dependent Elastic Spring Property
Description
Defines the frequency dependent property values for a PELAS bulk data entry.
Format
(1)

(2)

(3)

(4)

(5)

PELAST

PID

TKID

TGEID

TKNID

(6)

(7)

(8)

(9)

(10)

Field

Contents

PID

Property identification number. Must match with a PID of a PELAS bulk data
entry.
No default (Integer > 0)

TKID

Identification number of a TABLED# entry that defines the force per unit
displacement versus frequency relationship.
Default = 0 (Integer > 0)

TGEID

Identification number of a TABLED# entry that defines the element structural


damping coefficient versus frequency relationship.
Default = 0 (Integer > 0)

TKNID

Identification number of a TABLED# entry that defines the nonlinear force


versus displacement relationship.
Default = 0 (Integer > 0)

Comments
1.

Each PELAST entry must have a matching PELAS entry.

2.

PELAST is ignored in all solution sequences except frequency response analysis. Nominal
values from the PELAS entry are used in all the analyses except frequency response
analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide 1819


Proprietary Information of Altair Engineering

3.

If a particular TABLED id is blank or 0, the corresponding nominal value from the PELAS
entry will be used.

4.

The TKNID table is currently unused in nonlinear analysis and is ignored.

5.

This card is represented as a property in HyperMesh.

1820 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PERBC
Bulk Data Entry
PERBC Defines a connection between opposite edges/faces of the structure (Periodic
Boundary Conditions).
Description
The PERBC bulk data entry can be used to define a connection between opposite edges/faces
of the structure. This entry is used to apply Periodic Boundary Conditions to the model.
Format
(1)

(2)

(3)

(4)

(5)

PERBC

ID

GSID

RLID

TOL

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

PERBC

45

32

0.01

Field

Contents

ID

Set identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
GSID

Identification number of a SET of grid points on one side of the structure.


(Integer > 0)

RLID

Identification number of a RELOC bulk data entry that maps the nodes on one
side of the structure to the other. An exact one-to-one match between the two
sides is required.
(Integer > 0)

TOL

Specifies the numeric value defining the maximum distance between two grid
points to allow equivalence. All grid points in the set defined by GSID and the
set of grid points on the other side of the structure (mapping defined by the
RELOC entry) are considered for equivalence based on the tolerance.
(Real > 0.0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1821


Proprietary Information of Altair Engineering

Comments
1.

The PERBC entry can be used to apply periodic boundary conditions, to match results
from one side of the structure to another.

2.

The referenced RELOC Bulk Data Entry should be defined with TYPE=MOVE or
TYPE=ROTATE. For TYPE=ROTATE, a simple rotation about a single axis should only be
defined. All grids on one side of the structure (defined via GSID) and matching grids on
the other side should cannot have a coordinate system (Field CD on GRID entry) defined.
If RELOC(ROTATE) is specified, then all matching grids will have CD assigned automatically
to match the structure.

3.

Periodic Boundary Conditions are supported for all solution sequences (except OptiStructMulti-body Dynamics (OS-MBD) and Geometric Nonlinear Analysis (ANALYSIS=NLGEOM/
IMPDYN/EXPDYN)) and all optimization types. In shape optimization, when GRIDs identified
on the PERBC entry are in or near the optimized zone, their location changes should be
properly linked through DVGRID, otherwise the results may be incorrect.

1822 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFAST
Bulk Data Entry
PFAST CFAST Element Property
Description
Define properties of connector (CFAST) elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PFAST

PID

MC ID

MFLAG

KT1

KT2

KT3

KR1

KR2

KR3

MASS

GE

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PFAST

0.3

20

12800.0

8000.0

8000.0

(9)

(10)

0.8

Field

Contents

PID

Identification number of a PFAST entry.


No default (Integer > 0)

Diameter of the connector. See comment 2.


No default (Real > 0.0)

MCID

Identification number of the element stiffness coordinate system. See


comment 3.

Altair Engineering

OptiStruct 13.0 Reference Guide 1823


Proprietary Information of Altair Engineering

Field

Contents

MFLAG

Flag to indicate how the coordinate system specified by MCID will be


used.
If MFLAG = 0, MCID defines a relative coordinate system.
If MFLAG = 1, MCID defines an absolute coordinate system.
Default = 0 (Integer)

KTi

Stiffness values in directions 1 through 3.


Default = 0.0 (Real)

KRi

Rotational stiffness values in directions 4 through 6.


Default = 0.0 (Real)

MASS

Mass of the fastener. See comment 5.


Default = 0.0 (Real)

GE

Structural damping.
Default = 0.0 (Real)

Comments
1.

For a CFAST element, no material needs to be specified in the corresponding PFAST card
- the stiffness of the element is directly specified in the PFAST card with KTi and KRi
entries.

2.

The diameter D will not be involved in the stiffness calculation directly. It is used along
with GA and GB to find appropriate auxiliary points and related shell elements and grids. In
this case, the stiffness contribution of the fastener depends not only on the stiffness
values specified for KTi and KRi, but also the diameter D, because the location of the
auxiliary points will be used to weight the contribution of the shell element grids to GA and
GB of the fastener.

3.

Element stiffness coordinate system. The three stiffness values KT1, KT2 and KT3 will be
applied along the three axes of the element coordinate system. The unit vectors of the
three axes are denoted as e1, e2 and e3.
a) If MCID = -1, MFLAG will be ignored and e1 will be defined as:

e2 is defined as being perpendicular to e1 and lined up with the closest axis of the basic
system. This is accomplished by taking the inner product of e1 with the basic system unit
vectors. The smallest will define the basic system direction which is closest to the plane

1824 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

perpendicular to e1* e2 is then defined as the projection of the basic direction onto this
perpendicular plane. For example, assume m is the unit vector of the closest axis of the
basic system. The direction of e2 can be calculated as:

Unify this vector, then

At last, e3 can be calculated by the cross product of e1 and e2 as follows:


e3 = e1 x e2
b) If MCID > 0 and MFLAG = 0, e1 will be defined as:

in which XA and XB are the coordinates of GA and GB.


The T2 direction specified by MCID will be used to define the orientation vector v of the
fastener.
Then, e3 can be obtained as:

At last, the e2 can be easily calculated by the cross product of e3 and e1 as follows:
e2 = e3 x e1
c)
used directly as e1, e2 and e3. The element forces will be computed in the coordinate
system defined in comment 3(a).
d) If MCID refers to a cylindrical or spherical coordinate system, the local origin used to
locate the system is selected as follow: (i) if GA of the CFAST is specified, use GA as
the local origin; (ii) if GA is not specified but GS is specified, use GS as the local origin;
(iii) if neither GA nor GS is specified, use the point (XS, YS, ZS) as the local origin.
4.

The final length of the CFAST element is defined by the distance between GA and GB. If
the length is zero, the normal to shell patch A is used to define the axis of the fastener.

5.

For the mass of the fastener, half of the value defined in the MASS entry is placed
directly onto the translational degrees-of-freedom of GA and GB. Then they are
distributed, via auxiliary points, to corresponding shell grids. As the result, while the mass
will be represented correctly for general representation of the fastener in the vibrations of
the structure, the moments of inertia relative to the local axes of the fastener will only be

Altair Engineering

OptiStruct 13.0 Reference Guide 1825


Proprietary Information of Altair Engineering

roughly approximated.

1826 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFAT
Bulk Data Entry
PFAT Fatigue Properties
Description
Defines element properties for fatigue analysis
Format
(1)

(2)

(3)

(4)

(5)

(6)

PFAT

ID

Layer

Finish

Treatme
nt

Kf

(7)

(8)

(9)

Field

Contents

ID

Each PFAT card must have a unique ID. This ID may be referenced from a
FATDEF definition.

(10)

No default (Integer > 0)


Finish

Material Surface Finish, a result of manufacturing process. See comment 3.


Default = NONE (NONE, POLISH, GROUND, MACHINE, HOTROLL, FORGE or any
float value between 0.0 and 1.0)
When it is a float value, it will be used to modify the fatigue limit by multiplied
with the original fatigue limit.

Treatment

Material Surface Treatment for Material S-N Curve, a process used to enhance
the fatigue life. See comment 3.
Default = NONE (NONE, NITRIDED, SHOTPEEN, COLDROLL or any float value
great than 0.0)
When it is a float value, it will be used to modify the fatigue limit by multiplied
with the original fatigue limit.

Layer

Region Layer for shell elements. See comment 1.


Default = 0 (0 = Worst, 1 = Top, 2 = Bottom).

Kf

Fatigue strength reduction factor. See comments 2 and 3.


Default = 1.0 (Real > 1.0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1827


Proprietary Information of Altair Engineering

Comments
1.

If shell elements are used, it is necessary to specify the appropriate layer or Surface of
results to use Top or Bottom. Worst is the worst result of Top and Bottom (the one with
larger damage).

2.

Fatigue strength reduction factor takes into account the effect of notch effects, size
effects, and loading type influence,

where, Cnotch , Csize, and Cloading are correction factors for notch effect, size effect, and
loading type influence.
3.

Finish, Treatment and Kf are ignored in FOS analysis (TYPE=FOS on FATPARM).

4.

This card is represented as a loadcollector in HyperMesh.

1828 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFPATH
Bulk Data Entry
PFPATH Transfer Path Analysis
Description
Bulk Data Entry for One-Step Transfer Path Analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PFPATH

SID

C ONPT

RID

RTYPE

C ONEL

C ONREL

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

PFPATH

10

11

12

DISP

18

23

(8)

(9)

(10)

Argument

Options

SID

<INTEGER>

setid

The SID is referenced by a PFPATH


card in the control section.

CONPT

<INTEGER>

gsid

The connection points with a SID of


type GRID SET.

RID

<INTEGER>

rsid

The response SID of type GRIDC.


Contribution to each response DOF
through the connection points will be
calculated.

Altair Engineering

Description

OptiStruct 13.0 Reference Guide 1829


Proprietary Information of Altair Engineering

Argument

Options

Description

RPTYPE

DISP/VELO/ACCE
Default = DISP

Criterion for the type of the response; the response type


corresponding to a structural degree of freedom could be
displacement, velocity or acceleration.

CONEL

<INTEGER>

esid

The ELEMENT set consists of elements


connected to the connection GRIDs in
CONPT. These elements represent
connecting paths from the rest of the
system to the user-defined control
volume.

CONREL

<INTEGER>

rsid

The RIGID set consists of the RIGID


elements, connected to the connection
GRIDs in CONPT. These rigid elements
represent connecting paths from the
rest of the system to the user defined
control volume.

Comments
1.

There can be multiple PFPATH cards with the same SID.

2.

If CONREL is specified in the 7th entry, the RIGID element IDs must be unique.

1830 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PFBODY
Bulk Data Entry
PFBODY Flexible Body Definition for Multi-body Simulation
Description
Defines a flexible body out of a list of finite element properties, elements, and grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PFBODY

BID

BODY_NAME

TYPE1

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

TYPE2

ID9

ID10

TYPE#

G4

G5

G6

(10)

C MS

C TYPE

UB_FREQ

NMODES

FLXNODE

NOAUTO/C 1

G1

G2

G3

FLXNODE

C2

G8

G9

DTYPE

DVAL

DAMPING

Altair Engineering

OptiStruct 13.0 Reference Guide 1831


Proprietary Information of Altair Engineering

Example 1

(1)

(2)

PFBODY

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(10)

C ontrol_arm

PSHELL

23

21

PBEAM

59

48

C ONM2

2345

GRID

400

401

402

C MS

CB

FLXNODE

123

400

499

FLXNODE

123456

402

300

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PFBODY

901

902

903

1000

1001

50

Example 2

Linkage

PSOLID

13

15

C MS

CB

2000.0

FLXNODE

NOAUTO

FLXNODE

123

900

1832 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

FLXNODE

123456

11

12

13

DAMPING

C RATIO

0.8

Field

Contents

BID

Unique body identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


BODY_NAME

Unique body name.


This name is used as the Flex H3D file name to which the reduced
flexible body information will be written out for the PFBODY.
Default = OUTFILE_body_<BID>.h3d (Character string)

TYPE#

Flag indicating that the following list of IDs refer to entities of this
type. All property definitions; CELAS2, CONM2, PLOTEL, RBE2, RBE3,
RBAR, RROD, and GRID are valid types for this field.
No default (PBAR, PBARL, PBEAM, PBEAML, PBUSH, PCOMP, PCOMPP,
PCOMPG, PDAMP, PELAS, PGAP, PROD, PSHEAR, PSHELL, PSOLID,
PVISC, PWELD, CELAS2, CONM2, PLOTEL, RBE2, RBE3, RBAR, RROD, or
GRID)

ID#

Identification numbers of entities of the preceding TYPE flag.


No default (Integer > 0)

CMS

CMS flag indicating that information on the method used for reducing
the flexible body is to follow.

CTYPE

Component Mode Synthesis method to be employed.


CB - Craig-Bampton
CC - Craig-Chang
Default = CB (CB or CC)

UB_FREQ

Upper bound frequency for the eigenvalue analysis. If 0.0 or blank, no

Altair Engineering

OptiStruct 13.0 Reference Guide 1833


Proprietary Information of Altair Engineering

Field

Contents
upper bound is used. See comments 8 and 9.
Default = blank (Real > 0.0, or blank)

NMODES

Number of modes to be extracted from eigenvalue analysis. If set to -1


or blank, number of modes is limitless. See comments 8 and 9.
Default = blank (Integer > -1, or blank)

FLXNODE

FLXNODE flag indicating that flexible body interface node information is


to follow. See comment 11.

NOAUTO

NOAUTO flag to not automatically determine the interface nodes for the
flexible body.

C#

Component number indicating the interface degrees-of-freedom for the


following list of grids.
No default (up to 6 unique digits (0 < digit < 6) may be placed in the
field with no embedded blanks)

G#

Grid identification numbers.


(Integer > 0)

DAMPING

DAMPING flag indicating the flexible body modal damping.

DTYPE

Damping option.
Default = DEFAULT (DEFAULT or CRATIO)

DVAL

Damping ratio value if DTYPE is specified as CRATIO.


(Real > 0.0)

Comments
1.

A maximum of 56 characters may be given for BODY_NAME.

2.

Flex H3D file name will be <BODY_NAME>.h3d or OUTFILE_body_<BID>.h3d in the outfile


directory.

3.

Any number of property definitions; CELAS2, CONM2, PLOTEL, RBAR, RBE2, RBE3 or RROD
elements or grid points can be given.

1834 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

At least one property definition, element, or grid point must be given.

5.

A property definition; CELAS2, CONM2, PLOTEL, RBE2, RBE3, RBAR or RROD element or grid
point can only belong to one body (flexible or rigid).

6.

All property definitions, elements and grid points defined on a PFBODY bulk data entry
form one flexible body.

7.

CMS definition defines the component mode synthesis method to reduce the flexible body
for the multi-body analysis. Exactly one must be defined for each PFBODY.

8.

UB_FREQ and NMODES cannot both be blank.

9.

When UB_FREQ = 0.0 and NMODES = 0, this is a special case where no eigen modes will
be included in CMS mode generation.

10. If FLXNODE is not defined, a default set of interface nodes and degrees-of-freedom. will
be generated based on the actual interface nodes and degrees-of-freedom of the flexible
body.
11. One FLXNODE line can have up to six interface grid IDs. No continuation lines are
allowed. Add multiple FLXNODE lines to add more than six interface nodes.
12. This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1835


Proprietary Information of Altair Engineering

PGAP
Bulk Data Entry
PGAP Gap Element Property
Description
Defines properties of the gap (CGAP or CGAPG) elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PGAP

PID

U0

F0

KA

KB

KT

MU1

MU2

GPAD

FRIC ESL

Examples

(1)

(2)

(3)

(4)

(5)

PGAP

.025

2.5

1E6

(6)

(7)

(8)

(9)

1E6

0.25

0.25

0.3

0.3

(10)

Frictionless contact with automatic determination of U0 and KA:


PGAP

AUTO

AUTO

Minimum data required to prescribe Coulomb friction:


PGAP

1E6

Enforced stick condition (See comment 8):


PGAP

1E6

AUTO

1836 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

PID

Property identification number.


No default (Integer > 0)

U0

Initial gap opening.


Default = 0.0 (Real or AUTO). See comment 2.

F0

Preload. (Ignored in linear analysis).


Default = 0.0 (Real > 0.0)

KA

Axial stiffness for the closed gap. See comments 3 and 7.


No default (Real > 0.0 or AUTO, SOFT or HARD)

KB

Axial stiffness for the open gap. See comment 3.


Default = 10-14 * KB (Real > 0.0). This default is also set when KB=0.

KT

Transverse stiffness when the gap is closed. See comments 4 and 7.


Default = MU1 * KA (Real > 0.0 or AUTO)

MU1

Coefficient of static friction (ms). See comments 8 through 10. (Ignored in


linear analysis).
Default = 0.0 (Real > 0.0 or STICK or FREEZE)

MU2

Coefficient of kinetic friction (mk). (Ignored in linear analysis).


Default = MU1 (0.0 < Real < MU1)

GPAD

Padding to be added to account for additional layers on the surface of


obstacles A and B. Positive value reduces the initial gap opening. See
comment 11.
Default = NONE (Real or NONE or THICK; THICK applies only to CGAPG
elements)

FRICESL

Frictional elastic slip distance of sliding up to which the frictional


transverse force increases linearly with slip distance. Specified in physical
distance units (similar to U0 and GPAD). See comment 5.

Altair Engineering

OptiStruct 13.0 Reference Guide 1837


Proprietary Information of Altair Engineering

Field

Contents
Non-zero value activates respective friction model based on Elastic
Slip Distance.
Zero value or blank activates friction model based on prescribed
transverse stiffness KT.
Default = 0.0 (Real > 0.0)

Comments
1.

The gap element coordinate system is presented in the following figure. See the CGAP or
CGAPG entry for a more detailed description.

The C GAP or C GAPG Element C oordinate System

2.

With the optional value AUTO, the initial gap opening U0 is calculated automatically,
based on the distance between nodes GA and GB (in the original, undeformed mesh). For
gap elements with prescribed coordinate systems, this becomes a projection of vector
GA->GB onto the prescribed axis on the gap element (axis 1 of the coordinate system).

3.

The gap element force-displacement behavior is different in linear and nonlinear analysis
(see Nonlinear Quasi-Static Analysis for more information on nonlinear solutions). In linear
analysis, the gap stiffness is constant and depends on the initial gap opening U0 (as
shown in the figure below).

1838 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C GAP or C GAPG Element Force Deflection C urve for Linear Analysis

The gap force displacement behavior in nonlinear analysis is illustrated in the figure below.
While the gap is open, its normal stiffness is defined by KB. When the gap relative
displacement UA - UB becomes equal to the initial opening U0, first contact occurs. The
gap stiffness becomes KA upon contact.

C GAP or C GAPG Element Force Deflection C urve for Nonlinear Analysis

4.

When the gap is open, there is no transverse stiffness. When the gap is closed, friction
is activated and the gap has stiffness KT in the transverse direction (see 5 below for
alternative version). KT acts as a linear spring in linear solution sequences. For nonlinear
solution sequences, frictional force increases with sliding distance in proportion to KT until
it reaches static friction force MU1 * Fx, Fx being the normal force in the gap element.
With further transverse deformation, friction becomes kinetic and the friction force is MU2
* Fx. See the figure below for a one-dimensional illustration.

Altair Engineering

OptiStruct 13.0 Reference Guide 1839


Proprietary Information of Altair Engineering

C GAP or C GAPG Element Frictional Behavior in Nonlinear Analysis

5. In addition to the above formulation, in Release 12.0 an additional model of friction has
been introduced, based on Elastic Slip Distance and activated by presence of non-zero
FRICESL. This model typically has better performance in solution of frictional problems
thanks to more stable handling of transitions from stick to slip. Key differences between
the two available models are illustrated in the figure below (F 1 and F 2 represent two
different values of normal force F x ):

C omparison of the two available friction models for gap elements.

Model (a), based on fixed stiffness KT, is relatively simpler and only requires prescribing
coefficient of friction MU1 and MU2 (while KT can be determined automatically).
However, in Coulomb friction the frictional resistance depends upon normal force. Using
fixed KT will predict different range of stick/slip boundary for different normal forces,
and thus may qualify the same configuration as stick or slip, depending on normal
force.

1840 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Model (b), based on Elastic Slip Distance, provides unique identification of stick or slip
and generally performs better in solution of problems with friction. This model does
require prescribing elastic slip distance FRICESL (for gap elements, there is no
automatic determination of FRICESL a recommended value is about 0.5% of typical
element size in the neighborhood of the gap element).
6. Note that the nonlinear gap element's force-displacement behavior may produce negative
contributions to the compliance of the structure. For example, if KB > 0 and initial gap
opening U0 > 0, then the gap is essentially "preloaded" with an attractive force KB*U0. As
such a gap closes, the work done (and, hence, the gap's contribution to compliance) is
negative. Such very small negative contributions may even be produced if the KB field is
blank or zero this is due to the default non-zero value of KB applied in such cases. In
most situations, such small negative contributions get overridden by the overall positive
compliance of the entire structure. However, in some cases they may lead to negative
total compliance.
7. Reasonable gap stiffness: the gap stiffness values KA and KT essentially represent penalty
springs that are hard enough to prevent perceptible penetration of contacting nodes.
While, theoretically, higher stiffness values enforce the contact conditions more precisely,
excessively high values may cause difficulties in convergence or poor conditioning of the
stiffness matrix (this is especially true for KT). If any such symptoms are observed, it may
be beneficial to reduce the value of gap stiffness. A reasonable range of gap stiffness is
of the order of:
(103 to 106 ) * E * h
where, E is the typical value of elastic modulus and h is the typical element size in the
area surrounding the gap elements. Such a range will generally keep the gap penetration
below one thousandth / one millionth of the element size, respectively. A good value for
KT is of the order of 0.1*KA.
To facilitate reasonable values of KA and KT, automatic calculation of these parameters is
supported, specifically:
Option KA=AUTO determines the value of KA for each gap element using the stiffness
of surrounding elements. Additional options SOFT and HARD create respectively softer
or harder penalties. SOFT can be used in cases of convergence difficulties and HARD
can be used if undesirable penetration is detected in the solution.
Option KT=AUTO automatically calculates the value of KT. If MU1>0, the result here is
the same as with blank KT -- its value is calculated as MU1*KA. However, if MU1=0 or
blank, KT=AUTO produces a non-zero value of KT, calculated as KT=0.1*KA.
Therefore, KT=AUTO can be used to prescribe enforced stick conditions (see below).
8.

Prescribing MU1=STICK is interpreted as an enforced stick condition. (This can also be


accomplished by prescribing KT>0 or KT=AUTO with MU1=0 or blank). Such gap elements
will not enter the sliding phase. Of course, the enforced stick only applies to gaps that
are closed. Note that, in order to effectively enforce stick condition on gaps of non-zero
length,frictional offset may need to be turned off (See comment 10).

9.

Prescribing MU1=FREEZE enforces zero relative motion of the gap the gap opening
remains fixed at the original value and the sliding distance is zero. Also, rotations at GA
node are matched to the rotations of GB or the obstacle patch B. The FREEZE conditions
applies no matter whether the gap is open or closed (hence, U0 is of no relevance in this
case). The prescribed values of KB and KT are ignored. The value of KA is respected,

Altair Engineering

OptiStruct 13.0 Reference Guide 1841


Proprietary Information of Altair Engineering

although it is recommended that it is set to AUTO or HARD, to assure good connection.


Also, this condition is effective irrespective of the frictional offset setting.
10. The presence of friction or stick can introduce moment loadings and counter-intuitive
results into the problem by way of frictional offset. The reason is that for gap elements
with non-zero length (distance between GA and GB), the actual location of the contact
interface is presumed to be in the middle of the gap length (see figure below).

C GAP or C GAPG Presumed C ontact Surface

The frictional forces act along this contact surface. Transferring these forces to the grid
points GA and GB requires an offset operation that produces both forces and moments at
the gap grid points. Similarly, the sliding distance at the gap interface is a result of nodal
displacements and rotations at GA and GB (see figure below).

C GAP or C GAPG Sliding with Friction

For contact between bodies that do not support moments (solid elements, for example),
this offset may render friction ineffective because the free rotations at gap nodes offer
no effective resistance to friction. With the stick condition formally satisfied, for
example, nodes GA and GB can move relative to each other (see figure below).

1842 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

C GAP or C GAPG Stick (Zero Sliding Distance)

In practice, for gaps that are initially open, AUTOSPC will effectively fix respective
unsupported rotations. However, for gap elements that are initially closed (U0 < 0 or
U0=AUTO with CID=FLIP), the frictional terms will prevent AUTOSPC from being effective.
Hence, respective SPC on rotations need to be applied manually. (Note that this only
applies to "individual" gap end nodes GA and GB and is not needed for elements or patches
of nodes on the obstacle side of GAPG elements).
Effective in the Release 12.0, to avoid such counter-intuitive behavior, the frictional
offset operation is by default turned off if the model involves friction or stick and contains
at least one nonlinear subcase (of NLSTAT type). (Note that for consistency, this affects
both linear and nonlinear gap elements.) This produces more intuitive results with friction.
However, it may violate the rigid body balance of the body.
For linear gap analysis and for FREEZE condition, the offset operation is applied by default
(this produces correct rigid body balance, especially in natural frequency analysis).
The above default setting can be changed via the GAPOFFS command on the GAPPRM
card.
11. The GPAD option allows you to account for additional layers on the surface on obstacles
A and B, such as shell thickness or coatings on the surface of solids. Positive value
substracts from the gap opening U0, when calculated using AUTO option (GPAD is only
allowed when U0 is set to AUTO).
The GPAD option THICK automatically accounts for shell thickness on both sides of the
gap (this also includes the effects of shell element offset ZOFFS or composite offset Z0).
The THICK option applies only to CGAPG elements and is ignored for CGAP.
12. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1843


Proprietary Information of Altair Engineering

PGAPHT
Bulk Data Entry
PGAPHT Gap Element Heat Transfer Conduction Property for Heat Transfer Analysis
Description
Defines heat transfer conduction properties of the gap (CGAP or CGAPG) elements for heat
transfer analysis.
Format
(1)

(2)

(3)

(4)

PGAPHT

PID

KAHT

KBHT

(5)

(6)

(7)

(8)

(9)

(10)

TC ID

Examples

(1)

(2)

(3)

PGAPHT

1E6

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Contact with automatic determination of KAHT:


PGAPHT

AUTO

Minimum data required to prescribe clearance based contact conduction (see comments 2
and 3):
PGAPHT

10

Field

Contents

PID

Property identification number.


No default (Integer > 0)

KAHT

Total conduction for the closed gap. See comment 2.

1844 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
No default (Real > 0.0 or AUTO)

KBHT

Total conduction for the open gap. See comment 2.


Default = 10-14 * KAHT (Real > 0.0) This default is also set when KBHT=0.

TCID

Identification number of a TABLED# entry. This table specifies total gap


conduction based on gap clearance. See comments 2, 3, and 4.
Default = 0 (Integer > 0)

Comments
1.

PGAPHT provides heat transfer conductivity for CGAP/CGAPG element. PGAPHT must
match PID with an existing PGAP.

2.

KAHT and KBHT represent total gap conduction values for closed and open gaps.
Theoretically, while higher conduction values enforce a perfect conductor, excessively
high values may cause poor conditioning of the conductivity matrix. If any such
symptoms are observed, it may be beneficial to reduce the value of gap conduction, or
use conduction based contact clearance and pressure.
To facilitate reasonable values of KAHT, automatic calculation is supported, specifically:
Option KAHT=AUTO determines the value of KAHT for each gap element using the
conduction of surrounding elements.

3. TCID points to a TABLED# entry that specifies total conduction based on gap clearance.
TCID overrides KBHT. TCID is ignored for linear CGAP/CGAPG elements.
4. Thermal-structural analysis problems involving contact are fully coupled since contact/gap
status changes thermal conductivity. Refer to Contact-based Thermal Analysis in the
Users Guide for more information.
5. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1845


Proprietary Information of Altair Engineering

PGASK
Bulk Data Entry
PGASK Gasket Element Property Definition
Description
Defining the properties for solid gasket elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PGASK

PID

MIDG

MID1

C ORDM

H0

GAP

VOID

LEAKP

STABMT

Example

(1)

(2)

(3)

(4)

(5)

PGASK

(6)

(7)

(8)

(9)

(10)

0.5

Field

Contents

PID

Unique gasket element property identification number.


No default (Integer > 0)

MIDG

A MGASK entry identification number that defines thickness-direction and


transverse shear behaviors of the gasket.
No default (Integer > 0)

MID1

A MAT1 entry identification number that defines membrane properties and


mass density of the gasket.
Blank means zero membrane stiffness, zero membrane thermal expansion
coefficient, and zero mass density.
Default = blank (Integer > 0 or blank)

1846 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

CORDM

Material coordinate system identification number. See comment 3.


-1 means the element local coordinate system, while 0 means the basic
coordinate system.
Default = -1 (Integer > -1)

H0

Prescribed initial thickness of the gasket. See comment 4.


0.0 or blank means using initial thickness of the gasket element.
Default = 0.0 (Real > 0.0)

GAP

Initial open gap of the gasket. See comment 5.


Default = 0.0 (Real > 0.0)

VOID

Initial void of the gasket. See comment 5.


Default = 0.0 (Real > 0.0)

LEAKP

Leakage pressure. See comment 6.


Default = blank (Real > 0.0 or blank)

STABMT

Membrane and transverse shear stabilization flag.


0 - no stabilization.
1 - a stabilization stiffness is used if membrane or transverse shear stiffness
is zero.
Default = 0 (Integer = 0 or 1)

Comments
1.

All gasket element property entries must have unique identification numbers.

2.

PGASK refers to two material entries, MGASK and MAT1. MGASK defines the thicknessdirection and transverse shear behaviors of the gasket material, and MAT1 defines the
membrane behavior of the gasket material.
The thickness-direction stiffness is defined with the unit of stress per unit displacement
(the pressureclosure distance relationship for the thickness compression), the
transverse shear stiffness is defined with either the unit of stress per unit displacement
or the unit of force per unit area, and the membrane stiffness is defined with the unit of
force per unit area (the stressstrain relationship).

Altair Engineering

OptiStruct 13.0 Reference Guide 1847


Proprietary Information of Altair Engineering

3.

The gasket material coordinate system can be defined as the element local coordinate
system (CORDM = -1) or a prescribed system (CORDM = Integer > 0). The material local
3-direction is taken as the gasket thickness direction, and the material local 1-direction
and 2-direction are taken as the gasket membrane principle directions. If the angle
between the prescribed thickness direction (the material local 3-direction) and the default
one (the element local 3-direction) is larger than 20 degrees, a warning will be provided.

4.

The initial thickness includes initial open gap and initial void of the gasket.

5.

The total closure of a gasket element consists of the mechanical closure and the thermal
closure, that is:

Ctotal = Cmech + Cthermal


The thermal closure, Cthermal, is calculated as:

Cthermal = ALPHA * (Tref - T) * (H0 - GAP - VOID)


The effective closure, C, which is used to determine pressure with the loading/unloading
of tables defined in the MGASK card, is calculated as:

C = Cmech GAP
If there is no initial open gap (GAP=0), C and Cmech are identical.
6.

The sealing status of gasket is detected with the leakage pressure. If the gasket pressure
is larger than the leakage pressure, it is detected to be sealed the output status index
value is 1; otherwise, it is leaking the output status index value is 0.

7.

For gasket in contact, STABMT is recommended to be 1, if its membrane or transverse


shear stiffness is zero.

8.

The continuation entry is optional.

9.

This card is represented as a property in HyperMesh.

1848 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PHFSHL
Bulk Data Entry
PHFSHL Shell Element Property for One-Step Stamping Simulation
Description
Defines the thickness, material, blank holder, binder and Forming Limit Curve references for a
shell property in a one-step stamping simulation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PHFSHL

PID

MID

BHID

(7)

(8)

(9)

(10)

FLDID

Example

(1)

(2)

(3)

(4)

(5)

PHFSHL

0.01

(6)

(7)

(8)

(9)

(10)

Field

Contents

PID

Unique shell element property identification number.


No default (Integer > 0)

MID

Material identification number of a MATHF entry.


No default (Integer > 0)

Thickness
No default (Real > 0.0)

BHID

Blank holder ID referring to a BLKHDF entry.


No default (Integer > 0 or blank)

FLDID

User-defined Forming Limit Curve ID referring to FLDATA entry.


No default (Integer > 0 or blank)

Altair Engineering

OptiStruct 13.0 Reference Guide 1849


Proprietary Information of Altair Engineering

Comments
1.

This entry is only valid with an @HyperForm statement in the first line of the input file.

2.

All shell element property entries must have unique identification numbers.

3.

PHFSHL is referenced by CTRIA3 and CQUAD4 entries.

1850 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOAD
Bulk Data Entry
PLOAD Static Pressure Load
Description
Defines a static pressure load on a triangular or quadrilateral element. It can also be used to
define the EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and
TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

PLOAD

SID

G1

G2

G3

G4

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

PLOAD

-4.0

16

32

11

Field

Contents

SID

Load set identification number.

(8)

(9)

(10)

(Integer > 0)
P

Pressure.

G1,...G4 Grid point identification numbers.


(Integer > 0; G4 may be 0)
Comments
1.

The grid points define either a triangular or a quadrilateral element to which a pressure is
applied. If G4 is zero or blank, the element is triangular.

Altair Engineering

OptiStruct 13.0 Reference Guide 1851


Proprietary Information of Altair Engineering

In the case of a triangular element, the assumed direction of the pressure is computed
according to the right-hand rule using the sequence of grid points G1, G2, and G3.
2.

The total load on the element, AP, is divided into three equal parts and applied to the grid
points as concentrated loads. A minus sign in field 3 reverses the direction of the load.

3.

In the case of a quadrilateral element, the grid points G1, G2, G3, and G4 should form a
consecutive sequence around the perimeter. The right-hand rule is applied to find the
assumed direction of the pressure.

4.

This card is represented as a pressure load in HyperMesh.

1852 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOAD1
Bulk Data Entry
PLOAD1 Applied Load on CBAR or CBEAM Elements
Description
Defines concentrated, uniformly distributed, or linearly distributed applied loads to the CBAR or
CBEAM elements at user-chosen points along the axis. It can also be used to define the
EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk
data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD1

SID

EID

TYPE

SC ALE

X1

P1

X2

P2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD1

25

1065

MY

FRPR

0.2

2.5E3

0.8

3.5E3

Field

Contents

SID

Load set identification number.

(10)

No default (Integer > 0)


EID

CBAR or CBEAM element identification number.


No default (Integer > 0)

TYPE

Load type. See comment 5.


No default (FX, FY, FZ, FXE, FYE, FZE, MX, MY, MZ, MXE, MYE or MZE)

SCALE

Determines scale factor for X1, X2. See comments 6, 7, 8 and 9.


No default (LE, FR, LEPR or FRPR)

Altair Engineering

OptiStruct 13.0 Reference Guide 1853


Proprietary Information of Altair Engineering

Field

Contents

X1, X2

Distances along the CBAR or CBEAM element axis from end A.


For X1: No default; For X2: Default = blank (Real, 0 < X1 < X2)

P1, P2

Load factors at positions X1, X2.


Default = blank (Real or blank)

Comments
1.

In the static solution sequences, the load set ID (SID) is selected by the LOAD command
in the Subcase Information section.

2.
positions X1 and X2, having an intensity per unit length of bar equal to P1 at X1 and
equal to P2 at X2, except as noted in comments 8 and 9.
3.

If X2 is blank or equal to X1, a concentrated load of value P1 will be applied at position


X1.

4.
will be applied between positions X1 and X2, except as noted in comments 8 and 9.
5.

Load TYPE is used as follows to define loads:


"FX", "FY" or "FZ": Force in the x, y, or z direction of the basic coordinate system.
"MX", "MY" or "MZ": Moment in the x, y, or z direction of the basic coordinate system.
"FXE", "FYE" or "FZE": Force in the x, y, or z direction of the elements coordinate system.
"MXE", "MYE" or "MZE": Moment in the x, y, or z direction of the elements coordinate
system.

6.

If SCALE = "LE" (length), the xi values are actual distances along the element axis, and, if

7.

If SCALE = "FR" (fractional), the xi values are ratios of the distance along the axis to the

8.

If SCALE = "LEPR" (length projected), the xi values are actual distances along the element
element.

1854 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOAD1 C onvention on Beam or Bar Elements

If SCALE = "LE", the total load applied to the bar is P1 (X2 X1) in the y-basic direction.
If SCALE = "LEPR", the total load applied to the bar is P1 (X2 X1) cos in the y-basic
direction.
9.

If SCALE = "FRPR" (fractional projected), the Xi values are ratios of the actual distance to
in terms of the projected length of the bar.

10. Element identification numbers for CBAR and CBEAM entries must be unique.
11. Loads on CBEAM elements defined with PLOAD1 entries are applied along the line of the
shear centers.
12. If on the TYPE field of the PLOAD1 entry, the element coordinate system direction (for
example, TYPE = FYE) option is selected, then the projection (SCALE=FRPR or LEPR)
option is ignored and the result is the same as the SCALE=FR (or LE) option.
13. This card is represented as a pressure load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1855


Proprietary Information of Altair Engineering

PLOAD2
Bulk Data Entry
PLOAD2 Pressure Load on a Two-Dimensional Structural Element
Description
Defines a uniform static pressure load applied to two-dimensional elements. Only QUAD4 or
TRIA3 elements may have a pressure load applied to them via this entry. It can also be used
to define the EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1
and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD2

SID

EID

EID

EID

EID

EID

EID

(10)

Example

(1)

(2)

(3)

PLOAD2

21

-3.6

(4)

(5)

(6)

16

(7)

(8)

(9)

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD2

SID

EID1

THRU

EID2

blank

blank

blank

PLOAD2

30.4

16

THRU

48

Field

Contents

SID

Load set identification number.

(10)

(Integer > 0)

1856 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Pressure value.

EID, EID1, EID2

Element identification number.


(Integer > 0; EID1<EID2)

Comments
1.

EID must be 0 or blank for omitted entries.

2.

At least one positive EID must be present on each PLOAD2 entry.

3.

If the alternate form is used, all elements EID1 through EID2 must be two-dimensional.

4.

The direction of the pressure is computed according to the right-hand rule using the grid
point sequence specified on the element entry. Refer to the PLOAD entry.

5.

All elements referenced must exist.

6.

Continuations are not allowed.

7.

This card is represented as a pressure load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1857


Proprietary Information of Altair Engineering

PLOAD4
Bulk Data Entry
PLOAD4 Pressure Loads on Face of Structural Elements
Description
Defines a load on a face of a HEXA, PENTA, TETRA, PYRA, TRIA3, TRIA6, QUAD4, or QUAD8
element. It can also be used to define the EXCITEID field (Amplitude A) of dynamic loads in
RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PLOAD4

SID

EID

P1

P2

P3

P4

G1

G3 or
G4

C ID

N1

N2

N3

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD4

1106

10.0

8.0

5.0

1.0

48

0.0

1.0

0.0

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOAD4

SID

EID1

P1

P2

P3

P4

THRU

EID2

C ID

N1

N2

N3

1106

10.0

8.0

THRU

1143

0.0

1.0

0.0

PLOAD4

5.0

1858 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

Altair Engineering

Field

Contents

SID

Load set identification number.


(Integer > 0)

EID1, EID2

Element identification number.


(Integer > 0, EID1 < EID2)

P1, P2, P3, P4

Load per unit surface area (pressure) at the corners of the face of the
element (real or blank). (P1 is the default for P2, P3, and P4).

G1

Identification number of a grid point connected to a corner of the face.


Required data for solid elements only (Integer or blank). For PYRA
elements, this grid must be on an edge of the quadrilateral face.

G3

Identification number of a grid point connected to a corner diagonally


opposite to G1 on the same face of a HEXA or PENTA element. Required
data for quadrilateral faces of HEXA and PENTA elements only (Integer or
blank). G3 must be omitted for a triangular surface on a PENTA element
and the quadrilateral face on a PYRA element. For triangular faces of
PYRA elements, this grid must be on the edge next to the quadrilateral
face. G1 and G3 must define a positive direction into the element using
the right hand rule.

G4

Identification number of the TETRA grid point located at the corner not
on the face being loaded. This is required data and is used for TETRA
elements only.

CID

Coordinate system identification number.


(Integer > 0)

N1, N2, N3

Components of vector measured in coordinate system defined by CID


(Real). Used to define the direction (but not the magnitude) of the load
intensity. See comment 10.

Comments
1.

The continuation is optional. If fields 2, 3, 4, and 5 of the continuation are blank, the
load is assumed to be a pressure acting normal to the face. If these fields are not blank,
the load acts in the direction defined in these fields. Note that, if CID is a curvilinear
coordinate system, the direction of load may vary over the surface of the element. The
load intensity is the load per unit of surface area, not the load per unit of area normal to

Altair Engineering

OptiStruct 13.0 Reference Guide 1859


Proprietary Information of Altair Engineering

the direction of loading.


2.

For solid elements the direction of positive pressure (defaulted continuation card) is
inward. The load intensity P1 acts at grid point G1 and load intensities P2, P3 (and P4)
act at the other corners in a sequence determined by applying the right hand rule to the
outward normal.

3.

For plate elements the direction of positive pressure (defaulted continuation) is in the
direction of positive normal, determined by applying the right hand rule to the sequence of
connected grid points. The load intensities PI, P2, P3 (and P4) act respectively at corner
points G1, G2, G3 (and G4). (See plate connection).

4.

If P2, P3 (and P4) are blank fields, the load intensity is uniform and equal to P1. P4 has
no meaning for a triangular face and may be left blank in this case.

5.

Equivalent grid point loads are computed by linear (or bilinear) interpolation of load
intensity, followed by numerical integration using isoperimetric shape functions. Note that
uniform load intensity does not necessarily result in equal equivalent grid point loads.

6.

G1 and G3 are ignored for TRIA3, TRIA6, QUAD4, and QUAD8 elements.

7.

The alternate form is available only for TRIA3, TRIA6, QUAD4, and QUAD8 elements. The
continuation card may be used in the alternate form.

8.

For triangular faces of PENTA elements, G1 is an identification number of a corner grid


point that is on the face being loaded and the G3 or G4 field is left blank. For faces of
TETRA elements, G1 is an identification number of a corner grid point that is on the face
being loaded and G4 is an identification number of the corner grid point that is not on the
face being loaded. Since a TETRA has only four corner points, this point, G4, is unique
and different for each of the four faces of a TETRA element.

9.

For the quadrilateral face of the PYRA element, G1 is an identification number of a corner
grid point on the face and the G3 or G4 field is left blank. For the triangular faces, G1 and
G3 must specify the grids on the edge of the face that borders the quadrilateral face and
the grids must be ordered so that they define an inward normal using the right hand rule.

10. N1, N2, and N3 are not supported in NLGEOM subcases.


11. This card is represented as a pressure load in HyperMesh.

1860 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOADX1
Bulk Data Entry
PLOADX1 Static Pressure Load on Axisymmetric Element
Description
Defines a static surface traction on the CTAXI and CTRIAX6 axisymmetric elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PLOADX1

SID

EID

PA

PB

GA

GB

Theta

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PLOADX1

20

10.5

12.5

11

13

15.0

Field

Contents

SID

Load set identification number.

(9)

(10)

(Integer > 0)
EID

Element identification number.


(Integer > 0)

PA

Surface traction at grid point GA.


No default (Real)

PB

Surface traction at grid point GB.


Default = PA (Real or blank)

GA, GB

Identification numbers of two adjacent corner grid points on the element


side.

Altair Engineering

OptiStruct 13.0 Reference Guide 1861


Proprietary Information of Altair Engineering

Field

Contents
No default (Integer > 0)

Theta

Angle between surface traction and inward normal to the line segment.
Default = 0.0 (Real or blank)

Comments
1.

The surface traction is assumed to vary linearly along the element side between GA and
GB.

2.

The surface traction is input as force per unit area.

3.

Theta is measured counter-clockwise from the inward normal of the straight line
between GA and GB, to the vector of the applied load, as shown in the figure below.
Positive pressure is in the direction of inward normal to the line segment.

Pressure Load on C TRAX6 and C TAXI Elements

4.

This card is represented as a pressure load in HyperMesh.

1862 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOTEL
Bulk Data Entry
PLOTEL Dummy Plot Element Definition
Description
Defines a one-dimensional dummy element for use in plotting.
Format
(1)

(2)

(3)

(4)

PLOTEL

EID

G1

G2

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

PLOTEL

29

35

16

(5)

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


G1,G2

Grid point identification numbers of connection points.

Comments
1.

This element is not used in the model during any of the solution phases of a problem. It is
used to simplify the plotting of structures with large numbers of collinear grid points,
where the plotting of each grid point along with the elements connecting them would
result in a confusing plot.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

Only one PLOTEL element may be defined on a single entry.

4.

This card is represented as a plot element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1863


Proprietary Information of Altair Engineering

PLOTEL3
Bulk Data Entry
PLOTEL3 Dummy Plot Element Definition
Description
Defines a three-noded, two-dimensional dummy element for use in plotting.
Format
(1)

(2)

(3)

(4)

(5)

PLOTEL3

EID

G1

G2

G3

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

PLOTEL3

29

35

16

22

(6)

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


G1, G2, G3

Grid point identification numbers of connection points.

Comments
1.

This element is not used in the model during any of the solution phases of a problem. It is
used to simplify the plotting of large structures.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

This card is represented as a tria3 element in HyperMesh.

1864 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLOTEL4
Bulk Data Entry
PLOTEL4 Dummy Plot Element Definition
Description
Defines a four-noded, two-dimensional dummy element for use in plotting.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PLOTEL4

EID

G1

G2

G3

G4

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

PLOTEL4

29

35

16

22

23

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


G1, G2, G3, G4

Grid point identification numbers of connection points.

Comments
1.

This element is not used in the model during any of the solution phases of a problem. It is
used to simplify the plotting of large structures.

2.

Element identification numbers should be unique with respect to all other element
identification numbers.

3.

This card is represented as a quad4 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1865


Proprietary Information of Altair Engineering

PLSOLID
Bulk Data Entry
PLSOLID Nonlinear Hyperelastic Solid Element Property
Description
The PLSOLID bulk data entry defines the properties of nonlinear hyperelastic solid elements,
referenced by CHEXA, CPENTA, and CTETRA bulk data entries. The MATHE hyperelastic
material can be referenced to define corresponding material properties.
Format
(1)

(2)

(3)

PLSOLID

PID

MID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PLSOLID

Field

Contents

PEID

Unique solid element property identification number.


No default (Integer > 0)

MID

Identification number of a MATHE bulk data entry.


No default (Integer > 0)

Comments
1.

All solid element property entries must have unique identification numbers.

2.

The PLSOLID bulk data entry can be referenced by a CHEXA, CPENTA or CTETRA bulk
data entry.

3.

This card is represented as a property in HyperMesh.

1866 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PLY
Bulk Data Entry
PLY Ply Information for Ply-based Composite Definition
Description
Defines the properties of a ply used in ply-based composite definition.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PLY

ID

MID

THETA

SOUT

TMANUF

DID

ESID1

ESID2

ESID3

ESID4

ESID5

ESID6

ESID7

ESID9

(9)

(10)

ESID8

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

PLY

0.1

45

YES

0.01

(8)

(9)

(10)

Field

Contents

ID

Unique ply identification number.


No default (Integer > 0)

MID

Material identification number. Must refer to a MAT1, MAT2 or MAT8 bulk data
entry.
No default (Integer > 0)

Ply thickness.
No default (Real > 0.0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1867


Proprietary Information of Altair Engineering

Field

Contents

THETA

Ply orientation angle, in degrees, of the longitudinal direction relative to the xaxis of the material coordinate system associated with a given element. If no
material coordinate system is prescribed for the element, the angle is measured
relative to side 1-2 of this element.
Default = 0.0 (Real or blank)

SOUT

Stress, Strain, and Failure Index output request. See comments 2 and 3.
Default = NO (YES or NO)

TMANUF

Thickness of one manufacturable ply. See comment 4.


Default = blank (Real or blank)

DID

Draping identification number. Must refer to a DRAPE bulk data entry.


Default = blank (Integer > 0)

ESID#

Element SET identification numbers. Lists the elements for which this PLY card
is defined. No continuation line indicates that all elements should be included.
Default = blank (Integer > 0)

Comments
1.

The PLY card is used in combination with the PCOMPP and STACK cards to create
composite properties through the ply-based definition.

2.

Stress, Strain and Failure Index output for the PLY is activated by setting SOUT to YES.
In addition, the I/O Options CSTRESS (controlling Stress and Failure Index output) and/or
CSTRAIN (controlling Strain output) must be defined. Failure Index output also requires
that the FT and SB fields be defined on the corresponding PCOMPP card, and that stress/
strain allowables on the referenced materials are defined.

3.

An additional piece of information available with ply results is "failure index for the
element," which is the maximum of failure indices for individual plies in this element. Note
that only the plies with SOUT set to YES are considered in the evaluation of this
maximum.

4.

TMANUF defines the thickness of one manufacturable ply. This parameter is used during
sizing optimization to automatically create discrete design variables such that the
thickness of the ply bundle is equal to a multiple of TMANUF.

5.

This card is represented as a ply in HyperMesh.

1868 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PMASS
Bulk Data Entry
PMASS Scalar Mass Property
Description
Defines the mass value of a scalar mass element (CMASS1 or CMASS3 entry).
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PMASS

PID1

M1

PID2

M2

PID3

M3

PID4

M4

(10)

Example

(1)

(2)

(3)

(4)

(5)

PMASS

4.29

13.2

Field

Contents

PIDi

Property identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
Mi

Value of scalar mass.


(Real)

Comments
1.

Mass values are defined directly on the CMASS2 entry, and therefore do not require a
PMASS entry.

2.

Up to four mass values may be defined by this entry.

3.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1869


Proprietary Information of Altair Engineering

PRBODY
Bulk Data Entry
PRBODY Rigid Body Definition for Multi-body Simulation
Description
Defines a rigid body out of a list of finite element properties, elements and grid points.
Format
(1)

(2)

PRBODY

BID

(3)

(4)

(5)

(6)

(7)

(8)

(9)

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

TYPE2

ID1

ID2

TYPE#

IXY

IXZ

IYZ

C ID

(10)

BODY_NAME

TYPE1

MASS

INERTIA

IXX

IYY

IZZ

C OG

X,G

Example 1

(1)

(2)

PRBODY

3
PSHELL

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

ARM1
23

21

1870 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PBEAM

59

48

C ONM2

2345

GRID

400

401

402

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PRBODY

11

13

15

22

99

88

130.0

123.0

0.0

0.0

0.0

Example 2

PBAR

LEVER
10

44

MASS

100.0

INERTIA

120.0

C OG

29

Field

Contents

BID

Unique body identification number.


No default (Integer > 0)

BODY_NAME

Unique body name. This body name for this PRBODY.


Default = OUTFILE_body_<BID> (Character string)

TYPE#

Flag indicating that the following list of IDs refer to entities of this
type. All property definitions; CELAS2, CONM2, PLOTEL, RBE2, RBE3,
RBAR, RROD, and GRID are valid types for this field.

Altair Engineering

OptiStruct 13.0 Reference Guide 1871


Proprietary Information of Altair Engineering

Field

Contents
No default (PBAR, PBARL, PBEAM, PBEAML, PBUSH, PCOMP, PCOMPP,
PCOMPG, PDAMP, PELAS, PGAP, PROD, PSHEAR, PSHELL, PSOLID,
PVISC, PWELD, CELAS2, CONM2, PLOTEL, RBE2, RBE3, RBAR, RROD,
GRID)

ID#

Identification numbers of entities of the preceding TYPE flag.


No default (Integer > 0)

MASS

Flag to overwrite the finite element mass of the body. Indicates that
a mass value is to follow.

Mass.
(Real > 0.0)

INERTIA

Flag to overwrite the finite element inertia of the body. Indicates


that the inertia properties are to follow.

IXX,IYY,IZZ,
IXY,IXZ,IYZ

Moments of inertia.
(For IXX, IYY, IZZ Real > 0.0; For IXY, IXZ, IYZ Real)

CID

Coordinate system identification number to define the orientation of


the inertia tensor.
(Integer > 0 or blank)

COG

Flag to overwrite the finite element center of gravity of the body.


Indicates that the center of gravity is to follow.

X, Y, Z

Location of the center of gravity.


(Real)

Grid point identification number to optionally supply X, Y, and Z.


(Integer > 0)

Comments
1.

Any number of property definitions; CELAS2, CONM2, PLOTEL, RBAR, RBE2, RBE3 or RROD
elements or grid points can be given.

1872 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

At least one property definition, element, or grid point must be given.

3.

A property definition; CELAS2, CONM2, PLOTEL, RBE2, RBE3, RBAR or RROD element or grid
point can only belong to one rigid or flexible body.

4.

All property definitions, elements and grid points defined on a PRBODY bulk data entry
form one rigid body. The mass and inertia properties are defined by the finite element and
mass properties unless they are overwritten by the mass and inertia properties given on
the continuation lines.

5.

The mass, inertia and center of gravity input is optional if element/property information is
provided in the PRBODY definition.

6.

If one of MASS, INERTIA or COG continuations is provided, all three continuations must be
provided.

7.

A CID of zero or blank references the basic coordinate system.

8.

MASS must be positive non-zero values.

9.

If just the principal inertia is specified, IXX, IYY, and IZZ must be positive non-zero
values and they must satisfy the condition: the sum of two inertia values must be greater
than the third (IXX + IYY > IZZ, IYY+IZZ > IXX, IZZ+IXX > IYY).

10. This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1873


Proprietary Information of Altair Engineering

PRETENS
Bulk Data Entry
PRETENS 1D or 3D Bolt Pretension Section
Description
Defines 1D or 3D pretensioned bolt section.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PRETENS

SID

EID

SURFID

NTYP

G1/X1/
C ID

G2 / X2

G3 / X3

SPNTID

Examples

1D pretensioned bolt:
(1)

(2)

(3)

PRETENS

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

3D pretensioned bolt:
(1)

(2)

PRETENS

(3)

Field

Contents

SID

Unique section identification number.

EID

Element identification number of a bar, beam or rod element for defining


1D pretensioned bolt.
(Integer > 0 for 1D pretensioned bolt, or blank for 3D pretensioned bolt)

1874 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

SURFID

Identifier of SURF card which defines cutting section of 3D pretensioned


bolt.
(Integer > 0 for 3D pretensioned bolt, or blank for 1D pretensioned bolt)
See comment 2.

NTYP

Type of determination of normal to the pretension section. See


comment 3.
AUTO automatic determination based on the configuration of the
pretension section.
GRIDS use G1, G2, G3 to define the plane of pretension normal to
this plane defines the pretension direction.
VECTOR use the vector X1, X2, X3 to define pretension direction.
CID use prescribed coordinate system.
Default = blank = AUTO (AUTO, GRIDS, VECTOR, or CID).

G1, G2, G3

Three grid identifiers that define the plane where its normal is the
direction of the bolt.
Default = blank (Integer > 0). When prescribed, all three nodes must
be prescribed.

X1, X2, X3

Coordinates, in basic system, of the vector that defines direction of


pretension.
Default = blank (Real). The length of the vector must be non-zero.

CID

Identifier of a coordinate system that defines direction of pretension.


For rectangular system, the local x-axis defines the pretension
direction;
For cylindrical and spherical systems, the local z-axis defines the
pretension direction.
Default = blank (Integer > 0).

SPNTID

SPOINT that defines the DOF containing the pretension deformation and
load.
Default is not to output the pretension deformation in results files.

Comments
1.

Each 1D pretension section defines only one element.

Altair Engineering

OptiStruct 13.0 Reference Guide 1875


Proprietary Information of Altair Engineering

2.

A surface defined by SURFID should be constructed by solid elements on the same side of
the surface.

3.

The default direction of pretension is defined automatically from the configuration of the
pretension section.
For 1D elements, it is along the axis of the respective 1D element.
For 3D pretension, it is defined as the average normal to the respective SURFace
(average of respective element normals).

1876 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PRETPRM
Bulk Data Entry
PRETPRM Parameters for 1D and 3D bolt pretensioning
Description
Defines parameters that control initial loading conditions on pretension sections for 1D and 3D
bolt pretensioning. These parameters also control the printing of diagnostic information about
pretension sections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

PRETPRM

PARAM1

VAL1

PARAM2

VAL2

- etc -

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

PRETPRM

INILOAD

ZEROF

PRTSW

YES

Field

Contents

PARM#

Name of the parameter

VAL#

Value of the parameter

(6)

(7)

(8)

(9)

(10)

The available parameters and their values are listed below (click the parameter name for
parameter descriptions).

Parameter

Description

Values

INILOAD

Defines the handling of initial loading conditions


on pretension sections that have been defined,
but not yet explicitly loaded via PRETENSION
command.

"ZEROF or ZEROA
Default = ZEROF

Altair Engineering

OptiStruct 13.0 Reference Guide 1877


Proprietary Information of Altair Engineering

Parameter

Description

Values

PRTSW

Switch for printing diagnostic information about


pretension sections.

<YES, NO>
Default = NO

1878 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PRETPRM, INILOAD
Parameter
INILOAD

Values

Description

"ZEROF or ZEROA
Default = ZEROF

Defines the handling of initial loading conditions


on pretension sections that have been defined,
but not yet explicitly loaded via PRETENSION
command.
If ZEROF, in a pretensioning subcase, for any
pretension section without pretension load, zero
force will be applied. This is equivalent to
prescribing zero PTFORCE.
If ZEROA, zero relative deformation is
enforced on the pretension section defined
above. This is equivalent to prescribing zero
PTADJST.

Altair Engineering

OptiStruct 13.0 Reference Guide 1879


Proprietary Information of Altair Engineering

PRETPRM, PRTSW
Parameter
PRTSW

Values

Description

<YES, NO>
Default = NO

Switch for printing diagnostic information about


pretension sections.
If NO, diagnostic information will not be printed.
If YES, diagnostic information will be printed to
the .out file.

1880 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PROD
Bulk Data Entry
PROD Rod Property
Description
Defines the properties of a rod, which is referenced by the CROD entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PROD

PID

MID

NSM

(9)

(10)

Example

(1)

(2)

(3)

(4)

PROD

17

23

42.6

(5)

(6)

(7)

(8)

(9)

(10)

0.5

Field

Contents

PID

Unique rod property identification number.


No default (Integer > 0)

MID

Material identification number. See comment 1.


No default (Integer > 0)

Area of rod.
No default (Real)

Torsional constant.
No default (Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1881


Proprietary Information of Altair Engineering

Field

Contents

Coefficient to determine torsional stress.


Default = 0.0 (Real)

NSM

Nonstructural mass per unit length.


No default (Real)

Comments
1.

For structural problems, MID may reference only a MAT1 material entry. For heat transfer
problems, MID may reference only a MAT4 material entry.

2.

All rod property entries must have unique property identification numbers.

3.

Torsional stress is calculated as follows:

CM
J
Where,

is the torsional moment

C is the coefficient specified in field C


J is the torsional constant specified in field J
4.

This card is represented as a property in HyperMesh.

1882 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PSEAM
Bulk Data Entry
PSEAM CSEAM Element Property
Description
Define properties of connector (CSEAM) elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

PSEAM

PID

MID

TYPE

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

PSEAM

30

LINE

0.8

Field

Contents

PID

Property identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


MID

Material identification number of a MAT1 or MAT9 entry. See comment 1.


No default (Integer > 0)

TYPE

Type of seam weld generated.


Default = LINE (Character)

Width of the seam weld. See comment 2.


No default (Real > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1883


Proprietary Information of Altair Engineering

Field

Contents

Thickness of the seam weld. See comment 3.


No default (Real > 0)

Comments
1.

Material MID is used to calculate the stiffness of the connector (the fictitious CHEXA).
MID can only refer to the MAT1 or MAT9 bulk data entry.

2.

The distance between GS and GE is the length of the element. The width of the seam
weld is measured perpendicular to the length and lies in the plane of Shell A or B. See
figure below.

3.

If the entry of T is left blank, the thickness of this seam weld will be calculated as the
averaged thickness of Shell A and B.

4.

This card is represented as a property in HyperMesh.

1884 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PSEC
Bulk Data Entry
PSEC Section Property Definition
Description
Defines property information for planar section elements used in the definition of arbitrary
beam cross-sections.
Format
(1)

(2)

(3)

(4)

PSEC

PID

MID

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

PSEC

100

0.1

(5)

Field

Contents

PID

Property identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


MID

Identification number of a material definition.


No default (Integer > 0)

Thickness.
No default (Real > 0.0)

Comments
1.

All property identification numbers within a section definition must be unique with respect
to all other property identification numbers within the same section definition.

Altair Engineering

OptiStruct 13.0 Reference Guide 1885


Proprietary Information of Altair Engineering

2.

This entry is only valid when it appears between the BEGIN and END statements.

1886 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PSHEAR
Bulk Data Entry
PSHEAR Shear Panel Property
Description
Defines the properties of a shear panel.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

PSHEAR

PID

MID

NSM

F1

F2

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

PSHEAR

21

.001

(5)

(6)

Field

Contents

PID

Unique shear property identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
MID

Material identification number of a MAT1 entry.


(Integer > 0)

Thickness of shear panel.

NSM

Nonstructural mass per unit area.


(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 1887


Proprietary Information of Altair Engineering

Field

Contents

F1

Effectiveness factor for extensional stiffness along edges 1-2 and 3-4. See
comment 2.
Default = 0.0 (Real > 0.0)

F2

Effectiveness factor for extensional stiffness along edges 2-3 and 1-4. See
comment 2.
Default = 0.0 (Real > 0.0)

Comments
1.

The effective extensional area is defined by means of equivalent rods on the perimeter of
the element. If F1 < 1.01, the areas of the rods on edges 1-2 and 3-4 are set equal to
(F1 T PA)/(L12 + L34), where PA is the panel surface areas - half the vector
cross product area of the diagonals - and L12 and L34 are the lengths of sides 1-2 and 34. Thus, if F1 = 1.0, the panel is fully effective for extension in the 1-2 direction. If F1 >
1.01, the areas of the rods on edges 1-2 and 3-4 are each set equal to 0.5 F1 T.

Extensional Area for Shear Panel

Thus, if F1 = 30, the effective width of skin contributed by the panel to the flanges on
edges 1-2 and 3-4 is equal to 15T. The significance of F2 for edges 2-3 and 1-4 is
similar.
2.

Poisson's ratio coupling for extensional effects is ignored.

3.

This card is represented as a property in HyperMesh.

1888 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PSHELL
Bulk Data Entry
PSHELL Shell Element Property
Description
Defines the membrane, bending, transverse shear, and membrane-bending coupling of shell
elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PSHELL

PID

MID1

MID2

12I/T3

MID3

TS/T

NSM

Z1

Z2

MID4

T0

ZOFFS

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PSHELL

203

204

1.90

205

1.2

206

0.8

6.32

+.95

-.95

(10)

0.1

Field

Contents

PID

Unique shell element property identification number.


(Integer > 0)

MID1

Material identification number for membrane. See comment 3.


(Integer > 0)

Default value for the membrane thickness (Real > 0.0). If T0 is defined for
topology optimization, T is the total thickness.

Altair Engineering

OptiStruct 13.0 Reference Guide 1889


Proprietary Information of Altair Engineering

Field

Contents

MID2

Material identification number for bending. See comment 3.


(Integer > -1 or blank)

12I/T3

Bending stiffness parameter.


Default = 1.0 (Real > 0.0 or blank)

MID3

Material identification number for transverse shear. See comment 3.


(Integer > 0 or blank, must be blank unless MID2 > 0)

TS/T

Transverse shear thickness divided by the membrane thickness.


Default = .833333 (Real > 0.0 or blank)

NSM

Nonstructural mass per unit area.


(Real)

Z1,Z2

Fiber distances for stress computation. The positive direction is determined by


the right hand rule and the order in which the grid points are listed on the
connection entry.
(Real or blank, See comment 7 for defaults)

MID4

Material identification number for membrane-bending coupling.


(Integer > 0 or blank, must be blank unless MID1>0 and MID2>0, may not be
equal to MID1 or MID2). See comments 10 and 11.

T0

The base thickness of the elements in topology optimization. Only for MAT1,
T0 can be >0.0. If T0 is blank, then the elements are not included in the
topology design volume or space.
(Real > 0.0 or blank for MAT1, Real = 0.0 or blank for MAT2, MAT8)

ZOFFS

Offset from the plane defined by element grid points to the shell reference
plane.
Real or Character Input (Top/Bottom). See comment 15.

Comments
1.

All shell element property entries must have unique identification numbers.

1890 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

The structural mass is computed from the density using the membrane thickness and
membrane material properties.

3.

MID1 cannot be left blank. The effect of leaving an MID2 or MID3 field blank is:
MID2
(If left blank)

Pure membrane in plane stress no bending, coupling, or transverse


shear stiffness. MID3 and MID4 must also be blank.

MID3
(If left blank)

No transverse shear deformation is considered (this is actually


accomplished by enforcing very high transverse shear stiffness).

If MID2 = -1

Plane strain. In-plane stiffness only. No bending or transverse shear


stiffness. See comments 13 and 14.

4.

The continuation is not required.

5.

This entry is used in connection with the CTRIA3, CQUAD4, CTRIA6, and CQUAD8 entries.

6.

PSHELL entries may reference MAT1, MAT2, MAT4, MAT5, and MAT8 material property
entries.

7.

The default for Z1 is -T/2, and for Z2 it is +T/2. T is the local plate thickness, defined by
T on this entry. For free-sizing optimization, Z1 and Z2 definitions are ignored and the
defaults of T/2 and +T/2 are used for each element.

8.

If MID3 references a MAT2 material, then G33 on the MAT2 data must be blank.

9.

If MID3 references a MAT8 material, then G1Z and G2Z must not be blank.

10. MID4 provides a way to represent shells with offset (shell element centerline being offset
from the plane of the grid points) or shells with material properties that are not symmetric
with respect to the middle surface of the shell. However, whenever possible, the
preferred method of representing such shells is through the use of element offset ZOFFS
or the composite property PCOMP. This is because MID4 does not provide sufficient
information about the shell structure to correctly calculate all respective results,
specifically:
The shell stresses calculated in the presence of MID4 are generally incorrect, as they
do not reflect the actual shell offset or the non-uniform material structure.
The effects of MID4 are not considered in the calculation of differential stiffness.
Hence, it is recommended that MID4 be left blank in buckling analysis.
11. If MID4 points to a MAT2 card with a material ID greater than 400,000,000, then the
thermal membrane-bending coefficients A1, A2, and A12 have a modified interpretation,
and represent [G]*[alpha] rather then [alpha]. Here, [G] is a matrix composed of G11,
G22,G33. This is to maintain consistency with respective terms generated internally by
the PCOMP card.
12. Thermal expansion coefficients provided for materials referenced as MID2 or MID3 are
ignored in shell analysis - only the thermal expansion terms for materials referenced as
MID1 (membrane) and MID4 (coupling) are considered. Furthermore, the reference
temperature (TREF) for the shell property is taken from the material referenced as MID1 TREF's provided for other MID's are ignored.

Altair Engineering

OptiStruct 13.0 Reference Guide 1891


Proprietary Information of Altair Engineering

13. Plane strain (MID2=-1) MID1 must reference a MAT1 entry.


14. In plane strain computations, in-plane loads are interpreted as line loads with a value
equal to the load, divided by the thickness. Thus, if a thickness of "1.0" is used, the
value of the line-load equals the load value. Pressure can be approximated with multiple
line loads where the pressure value equals the line-load, divided by the length between
the loads.
15. The shell reference plane can be offset from the plane defined by the element nodes by
means of ZOFFS. In this case all other information, such as material matrices or fiber
locations for the calculation of stresses, is given relative to the offset reference plane.
Shell results, such as shell element forces, are output on the offset reference plane.
ZOFFS can be used in all types of analysis and optimization.
ZOFFS can be input in two different formats:
1. Real:
A positive or a negative value of ZOFFS is specified in this format. A positive value of
ZOFFS implies that the reference plane of each shell element is offset a distance of
ZOFFS along the positive z-axis of its element coordinate system.
2. Surface:
This format allows you to select either Top or Bottom option to specify the offset
value.
Top:
The top surface of the shell element and the plane defined by the element nodes are
coplanar.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
element. (The sign of the ZOFFS value would depend on the direction of the offset with
respect to the positive z-axis of the element coordinate system, as defined in the Real
section). See Figure 1.

Figure 1: Top option in ZOFFS

Bottom:
The bottom surface of the shell element and the plane defined by the element nodes are
coplanar.
This makes the effective "Real" ZOFFS value equal to half of the thickness of the PSHELL
element. (The sign of the ZOFFS value would depend on the direction of the offset with

1892 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

respect to the positive z-axis of the element coordinate system, as defined in the Real
section). See Figure 2.

Figure 2: Bottom option in ZOFFS

When ZOFFS is used, both MID1 and MID2 must be specified; otherwise singular matrices
would result.
Moreover, while offset is correctly applied in geometric stiffness matrix and thus can be
used in linear buckling analysis, caution is advised in interpreting the results. Without
offset, a typical simple structure will bifurcate and loose stability instantly at the critical
load, shown in Figure (a). With offset though, the loss of stability is gradual and
asymptotically reaches a limit load, as shown below in Figure (b).

Thus, the structure with offset can reach excessive deformation before the limit load is
reached. Note that the above illustrations apply to linear buckling in a fully nonlinear
limit load simulation, additional instability points may be present on the load path.
16. This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1893


Proprietary Information of Altair Engineering

PSHELLX
Bulk Data Entry
PSHELLX Optional SHELL Property Extension for Geometric Nonlinear Analysis
Description
Defines additional SHELL properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PSHELLX

PID

ISHELL

ISH3N

ISMSTR

NIP

HM

HF

HR

DM

DN

ITHIC K

IPLAS

(10)

Example

(1)

(2)

(3)

(4)

(5)

PSHELL

73

1.0

PSHELLX

73

24

(6)

(7)

(8)

(9)

(10)

Field

Contents

PID

Property ID of the associated PSHELL. See comment 1.


No default (Integer > 0)

ISHELL

Flag for CQUAD4 element formulation.


Default as defined by XSHLPRM (Integer)
1 - Q4, visco-elastic hourglass modes orthogonal to deformation and rigid
modes (Belytschko).
2 - Q4, visco-elastic hourglass without orthogonality (Hallquist).

1894 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
3 - Q4, elastic-plastic hourglass with orthogonality.
4 - Q4 with improved type 1 formulation (orthogonalization for warped
elements).
12 - QBAT or DKT18 shell formulation.
24 - QEPH shell formulation.

ISH3N

Flag for CTRIA3 element formulation.


Default as defined by XSHLPRM (Integer)
1 - Standard triangle (C0).
2 - Standard triangle (C0) with modification for large rotation.
30 - DKT18.
31 - DKT_S3.

ISMSTR

Flag for shell small strain formulation.


Default as defined by XSHLPRM (Integer)
1 - Small strain from time = 0.
2 - Full geometric non-linearity with optional small strain formulation activation
by time step XSTEP, TYPEi = SHELL, TSCi = CST.
3 - Alternative small strain formulation from time = 0 (ISHELL =2 only).
4 - Full geometric non-linearity (Time step limit has no effect).

NIP

Number of integration points through the thickness. NIP = 0 defines global


integration.
Default as defined by XSHLPRM (0 < Integer < 10)

HM

Shell membrane hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (Real, 0.0 < HM < 0.05)
Except ISHELL = 3: Default = 0.1 (Real)

HF

Shell out of plane hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (0.0 < Real < 0.05)

Altair Engineering

OptiStruct 13.0 Reference Guide 1895


Proprietary Information of Altair Engineering

Field

Contents

HR

Shell rotation hourglass coefficient (ISHELL = 1, 2, 3, and 4 only).


Default = 0.01 (0.0 < Real < 0.05)
Except ISHELL = 3: Default = 0.1 (Real)

DM

Shell membrane damping (with MATX27 and MATX36 only).


Default: See comment 11 (Real)

DN

Shell numerical damping (ISHELL = 12, 24, ISH3N = 30 only)


Default: See comment 12 (Real)

ITHICK

Flag for shell resultant stresses calculation.


Default as defined by XSHLPRM (CONST or VAR)
CONST - Thickness is constant.
VAR - Thickness change is taken into account.

IPLAS

Flag for shell plane stress plasticity (with MATX2, MATX27, and MATX36 only).
Default as defined by XSHLPRM (RAD or NEWT)
RAD - Radial return.
NEWT - Iterative projection with 3 Newton iterations.

Comments
1.

The property identification number must be that of an existing PSHELL bulk data entry.
Only one PSHELLX property extension can be associated with a particular PSHELL.

2.

PSHELLX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

Q4: Original 4 node OptiStruct shell with hourglass perturbation stabilization.


QEPH: Formulation with physical hourglass stabilization for general use.
QBAT: Modified BATOZ Q4g 24 shell with 4 Gauss integration points and reduced
integration for in-plane shear. No hourglass control is needed for this shell.
DKT18: BATOZ DKT18 thin shell with 3 Hammer integration points.

1896 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

If the small strain option (ISMSTR) is set to 1 or 3, engineering strain and stress are
used; otherwise they are true strain and stress.

5.

ISHELL = 2 is incompatible with NIP = 1.

6.

Global integration (NIP = 0) is only compatible with MAT1, MATS1, MATX2, and MATX36.

7.

For MAT1, membrane only behavior happens if NIP = 1. Otherwise, NIP is ignored and
global integration (NIP = 0) is used.

8.

For ITHICK = VAR it is recommended to use IPLAS = NEWT.

9.

If ITHICK = VAR or IPLAS = NEWT, the small strain option is automatically deactivated.

10. For MATX2, the default value for IPLAS and global integration (NIP=0) is IPLAS = RAD.
11. For MATS1, MATX36 the default value for IPLAS and global integration (NIP=0) is IPLAS =
NEWT.
12. Defaults for DM:
Material

Element type

ISHELL/ISH3N Default

MATX27

except QEPH, QBAT

except 12, 24

5%

QEPH

24

1.5%

QBAT

12

0%

except QEPH

except 24

0%

QEPH

24

1.5%

MATX36

13. Defaults for DN:


Element type ISHELL/ISH3N

Default

Usage

QBAT

12

0.1%

All stress terms, except transverse


shear.

QEPH

24

1.5%

Hourglass stress.

DKT18

12/30

0.01%

Membrane stress only.

14. This card is represented as an extension to a PSHELL property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1897


Proprietary Information of Altair Engineering

PSLDX6
Bulk Data Entry
PSLDX6 Optional SOLID Property Extension for Geometric Nonlinear Analysis
Description
Defines additional orthotropic SOLID properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PSLDX6

PID

ISOLID

NIP

ISMSTR

IC PRE

IFRAME

DN

QS

QB

HV

DTMIN

C ID

IP

IORTH

Vx

Vy

Vz

THETA

(10)

Example

(1)

(2)

(3)

PSOLID

77

PSLDX6

77

24

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property ID of the associated PSOLID. See comment 1.

(9)

(10)

No default (Integer > 0)


ISOLID

Flag for solid elements formulation.


Default as defined by XSOLPRM (Integer)
1 - Standard 8-node solid element, 1 integration point. Viscous
hourglass formulation with orthogonal and rigid deformation modes
compensation (Belytschko).
2 - Standard 8-node solid element, 1 integration point. Viscous

1898 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
hourglass formulation without orthogonality (Hallquist).
12 - Standard 8-node solid, full integration (no hourglass).
14 - HA8 locking-free 8-node solid element, co-rotational, full
integration, variable number of Gauss points.
17 - H8C compatible solid full integration formulation.
24 - HEPH 8-node solid element. Co-rotational, under-integrated (1
Gauss point) with physical stabilization.

NIP

Number of integration points (ISOLID = 14 and 16 only).


Default as defined by XSOLPRM (Integer = ijk)
2 < i, j, k < 9
< 3, 2 < j < 9

for ISOLID =14


for ISOLID =16

where:
i = Number of integration points in local x direction.
j = Number of integration points in local y direction.
k = Number of integration points in local z direction.
ISMSTR

Flag for small strain formulation (ISOLID = 1, 2, 14, and 24 only).


Default as defined by XSOLPRM (Integer)
1 - Small strain from time = 0.
2 - Full geometric non-linearity with small strain formulation activation
by time step.
3 - Simplified small strain formulation from time=0 (non-objective
formulation).
4 - Full geometric non-linearity. Time step limit has no effect.
10 - Lagrange type total strain.

ICPRE

Flag for reduced pressure integration (ISOLID = 14 and 24 only).


Default = OFF (ON, OFF, or VAR)
VAR - Variable state between ICPRE = ON and ICPRE = OFF in
function of plasticity state.

Altair Engineering

OptiStruct 13.0 Reference Guide 1899


Proprietary Information of Altair Engineering

Field

Contents

IFRAME

Flag for element coordinate system formulation (ISOLID = 1, 2, 12,


and 17 only).
Default as defined by XSOLPRM (ON or OFF)

DN

Numerical damping for stabilization (ISOLID =24 only).


Default = 0.1 (Real)

QS

Quadratic bulk viscosity.


Default = 1.1 (Real)

QB

Linear bulk viscosity.


Default = 0.05 (Real)

HV

Hourglass viscosity coefficient.


Default = 0.1 (0.0 < Real < 0.15)

DTMIN

Minimum time step.


Default = 0.0 (Real)

CID

Coordinate system identification number to define orthotropic


directions.
(Integer > 0)

IP

Reference plane.
Default = 0 (Integer)
0 - Use CID (CID must be different from 0)
1 - Plane (r,s) and angle THETA
2 - Plane (s,t) and angle THETA
3 - Plane (t,r) and angle THETA
11 - Plane (r,s) and orthogonal projection of reference vector (Vx,
Vy, and Vz) on plane (r,s)
12 - Plane (s,t) and orthogonal projection of reference vector (Vx,

1900 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Vy, and Vz) on plane (s,t)
13 - Plane (t,r) and orthogonal projection of reference vector (Vx,
Vy, and Vz) on plane (t,r)

IORTH

Flag for orthotropic system formulation.


(Integer = 0, 1)
0 - The first axis of orthotropy is maintained at constant angle with
respect to the orthonormal co-rotational element coordinate system.
1 - The first orthotropy direction is constant with respect to a nonorthonormal isoparametric coordinates.

Vx

X component for reference vector.


(Real)

Vy

Y component for reference vector.


(Real)

Vz

Z component for reference vector.


(Real)

THETA

Orientation angle in degrees of orthotropic with first reference plane


direction.
Default = 0.0 (Real)

Comments
1.

The property identification number must be that of an existing PSOLID bulk data entry.
Only one PSLDX6 property extension can be associated with a particular PSOLID.

2.

PSLDX6 is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

PSLDX6 is only compatible with 8-node linear solid elements. Quadratic 20-node brick and
6-node pentahedron elements are not compatible, these element types should only be
used with PSOLIDX.

4.

The ISOLID flag is not used with CTETRA elements. For elements with 4 and 10 nodes,
the number of integration points is fixed at 1 and 4, respectively.

Altair Engineering

OptiStruct 13.0 Reference Guide 1901


Proprietary Information of Altair Engineering

5.

For fully-integrated solids (SOLID =12), the deviatoric behavior is computed using 8 Gauss
points; bulk behavior is under-integrated to avoid element locking. It is currently
compatible with material MAT1, MATS1, MATX33, and MATX36.

6.

With the small strain option (ISMSTR), strain and stress is engineering strain and stress.
Otherwise, it is true strain and stress.

7.

In time history and animation files, the stress tensor is written in the co-rotational frame.

8.

Fully-integrated elements (ISOLID =12) only use full geometric non-linearity (corresponds
to ISMSTR = 4). Time step limit has no effect.

9.

ISMSTR =10 is only compatible with materials using total strain formulation (MATX42).

10. The time step control XSTEP, TYPEi = SOLID, TSCi = CST only works on elements with
ISMSTR =2.
11. Co-rotational formulation: For ISOLID = 1, 2, 12 and IFRAME = ON, the stress tensor is
computed in a co-rotational coordinate system. This formulation is more accurate if large
rotations are involved. It comes at the expense of higher computation cost. It is
recommended in case of elastic or visco-elastic problems with important shear
deformations. The co-rotational formulation is compatible with 8 node solids.
12. For HA8 (ISOLID = 14) elements: this element uses a locking-free general solid
formulation, co-rotational. The number of Gauss points is defined by NIP flag: for
example, combined with NIP = 222 gives an 8 Gauss integration point element, similar to
ISOLID = 12. The HA8 formulation is compatible with all material laws. Under-integration
for pressure should be used (ICPRE = ON in case of elastic or visco-elastic material; ICPRE
= VAR in case of elasto-plastic material).
13. For H8C (SOLID = 17) elements: Their brick deviatoric behavior is the same as ISOLID =
12, but the bulk behavior can be chosen with ICPRE, and is compatible with all solid type
material laws. ICPRE = VAR is the default value and ICPRE = OFF will not reduce pressure
integration.
14. For HEPH (ISOLID = 24) elements: This element uses an hourglass formulation similar to
QEPH shell elements.
15. ICPRE = VAR is only available for elasto-plastic material law.
16. The hourglass formulation is viscous for ISOLID = 0, 1, and 2.
17. Hourglass viscosity coefficient, HV is not active with 8 point integration.
18. This card is represented as an extension to a PSOLID property in HyperMesh.

1902 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PSOLID
Bulk Data Entry
PSOLID Solid Element Property
Description
Defines the properties of solid elements, referenced by CHEXA, CPENTA, CPYRA and CTETRA
bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

PSOLID

PID

MID

C ORDM

(6)

(7)

(8)

(9)

ISOP

FC TN

DS

(10)

Example

(1)

(2)

(3)

PSOLID

100

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Field

Contents

PID

Unique solid element property identification number.


No default (Integer > 0)

MID

Identification number of a MAT1, MAT4, MAT5, MAT9, MAT10 or


MATPE1 bulk data entry.
No default (Integer > 0)

CORDM

MID of material coordinate system. The default is 0, which is the


basic coordinate system.
Default = 0 (Integer > -1)

ISOP

Special integration schemes for elasto-plastic nonlinear quasi-static


analysis. The values available are:

Altair Engineering

OptiStruct 13.0 Reference Guide 1903


Proprietary Information of Altair Engineering

Field

Contents
FULL full integration, using the same integration schemes as for
linear applications.
MODPLAST (default) uses special handling of pressure
approximation, designed to circumvent the volumetric locking due to
incompressibility of plastic flow. The specific details differ depending
on the type and order of the element.
REDPLAST besides special handling for pressure approximation, uses
reduced integration for second-order hexa and penta, and for 8noded hexa elements (reduced integration is not practically viable in
other element types, since it would create extensive spurious
modes).
See comments 2 and 3.
(Character: FULL, MODPLAST, REDPLAST or blank)

FCTN

Fluid element flag.


SMECH indicates a structural element; PFLUID indicates a fluid
element. PORO indicates poro-elastic material.
Default = SMECH (SMECH, PFLUID or PORO)

DS

Design switch. If non-zero, the elements associated with this PSOLID


data are included in the topology design volume or space.
Not valid for fluid elements.
Default = blank (Integer or blank)

Comments
1.

All solid element property entries must have unique ID numbers.

2.

Special integration flags MODPAST and REDPLAST affect only elasto-plastic materials (as
identified by presence of MATS1) in nonlinear quasi-static subcases. They do not affect
element behavior in linear analysis.

3.

The FULL option in the ISOP field provides stable and convergent results, although it may
appear stiff and converge rather slowly in cases of significant plastic deformation.
MODPLAST uses special handling for volumetric pressure term, in effect providing good
resolution of plastic flow while avoiding excessive flexibility that would lead to spurious
modes. REDPLAST adds further release of locking tendencies and usually the softest
behavior. It may, theoretically, exhibit spurious deformation modes in single unattached
elements, although in practice these modes should vanish in fields of many elements.

1904 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

If FCTN = 'PFLUID', then the MID must reference a MAT10 entry. If FCTM=PORO, then
MID must reference a poro-elastic material entry.

5.

Stresses are calculated in the material coordinate system. The material coordinate
system may be defined as the basic coordinate system (CORDM = 0), a defined system
(CORDM = Integer > 0), or the element coordinate system (CORDM = -1). Refer to the
CHEXA, CPENTA, CPYRA and CTETRA pages of the Reference Guide for details on how the
material coordinate system is defined for each element.

6.

If the material referenced by MID is a MAT9 material definition, then CORDM defines the
material coordinate system for Gij on the MAT9 entry.

7.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1905


Proprietary Information of Altair Engineering

PSOLIDX
Bulk Data Entry
PSOLID Optional SOLID Property Extension for Geometric Nonlinear Analysis
Description
Defines additional SOLID properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PSOLIDX

PID

ISOLID

NIP

ISMSTR

IC PRE

IFRAME

DN

QS

QB

HV

DTMIN

LAMBDAV

MUV

IHKT

(10)

Example

(1)

(2)

(3)

PSOLID

77

PSOLIDX

77

24

(4)

(5)

(6)

(7)

(8)

Field

Contents

PID

Property ID of the associated PSOLID. See comment 1.

(9)

(10)

No default (Integer > 0)


ISOLID

Flag for solid elements formulation.


Default as defined by XSOLPRM (Integer)
1 - Standard 8-node solid element, 1 integration point. Viscous
hourglass formulation with orthogonal and rigid deformation modes
compensation (Belytschko).
2 - Standard 8-node solid element, 1 integration point. Viscous

1906 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
hourglass formulation without orthogonality (Hallquist).
12 - Standard 8-node solid, full integration (no hourglass).
14 - HA8 locking-free 8-node solid element, co-rotational, full
integration, variable number of Gauss points.
16 - Quadratic 20-node solid, full integration, variable number of
Gauss points.
17 - H8C compatible solid full integration formulation.
24 - HEPH 8-node solid element. Co-rotational, under-integrated (1
Gauss point) with physical stabilization.

NIP

Number of integration points (ISOLID = 14, 16 only).


Default as defined by XSOLPRM (Integer = ijk)
2 < i, j, k < 9
< 3, 2 < j < 9

for ISOLID =14


for ISOLID =16

where:
i = Number of integration points in local x direction.
j = Number of integration points in local y direction.
k = Number of integration points in local z direction.
ISMSTR

Flag for small strain formulation (ISOLID = 1, 2, 14, and 24 only).


Default as defined by XSOLPRM (Integer)
1 - Small strain from time = 0.
2 - Full geometric non-linearity with small strain formulation activation
by time step.
3 - Simplified small strain formulation from time=0 (non-objective
formulation).
4 - Full geometric non-linearity. Time step limit has no effect.
10 - Lagrange type total strain.

ICPRE

Flag for reduced pressure integration (ISOLID = 14, 17, and 24 only).
Default = OFF for ISOLID = 14, 24, ON for ISOLID = 17 (ON, OFF, or
VAR)

Altair Engineering

OptiStruct 13.0 Reference Guide 1907


Proprietary Information of Altair Engineering

Field

Contents
VAR - Variable state between ICPRE = ON and ICPRE = OFF in
function of plasticity state.

IFRAME

Flag for element coordinate system formulation (ISOLID = 1, 2, 12, 17


only).
Default as defined by XSOLPRM (ON or OFF)

DN

Numerical damping for stabilization (ISOLID =24 only).


Default = 0.1 (Real)

QS

Quadratic bulk viscosity.


Default = 1.1 (Real)

QB

Linear bulk viscosity.


Default = 0.05 (Real)

HV

Hourglass viscosity coefficient.


Default = 0.1 (0.0 < Real < 0.15)

DTMIN

Minimum time step.


Default = 0.0 (Real)

LAMBDAV

Numerical Navier Stokes viscosity


No default (Real)

MUV

Numerical Navier Stokes viscosity


No default (Real)

IHKT

Hourglass tangent modulus flag (ISOLID = 24 only)


Default = 1 (Integer = 1, 2)
1 - Elastic modulus or numerical tangent modulus estimation.
2 - Advanced tangent modulus estimation.

1908 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The property identification number must be that of an existing PSOLID bulk data entry.
Only one PSOLIDX property extension can be associated with a particular PSOLID.

2.

PSOLIDX is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The ISOLID flag is not used with CTETRA elements. For these elements with four and ten
nodes, the number of integration points is fixed at one and four, respectively.

4.

For fully integrated solids (SOLID =12), the deviatoric behavior is computed using 8 Gauss
points; bulk behavior is under-integrated to avoid element locking. It is currently
compatible with material MAT1, MATS1, MATX33, and MATX36.

5.

With the small strain option (ISMSTR), strain and stress is engineering strain and stress.
Otherwise, it is true strain and stress.

6.

In time history and animation files, the stress tensor is written in the co-rotational frame.

7.

Fully integrated elements (ISOLID =12) only uses full geometric non-linearity (corresponds
to ISMSTR = 4). Time step limit has no effect.

8.

ISMSTR = 10 is only compatible with materials using total strain formulation (MATX42).

9.

The time step control XSTEP, TYPEi = SOLID, TSCi = CST only works on elements with
ISMSTR = 2.

10. Co-rotational formulation: For ISOLID = 1, 2, 12 and IFRAME = ON, the stress tensor is
computed in a co-rotational coordinate system. This formulation is more accurate if large
rotations are involved. It comes at the expense of higher computation cost. It is
recommended in case of elastic or visco-elastic problems with important shear
deformations. The co-rotational formulation is compatible with 8 node solids.
11. HA8 (ISOLID = 14) elements: this element uses a locking-free general solid formulation,
co-rotational. The number of Gauss points is defined by NIP flag: for example, combined
with NIP = 222 gives an 8 Gauss integration point element, similar to ISOLID = 12. The
HA8 formulation is compatible with all material laws. Under-integration for pressure should
be used (ICPRE = ON in case of elastic or visco-elastic material; ICPRE = VAR in case of
elasto-plastic material).
12. H8C (SOLID = 17) elements: Their brick deviatoric behavior is the same as ISOLID = 12,
but the bulk behavior can be chosen with ICPRE, and is compatible with all solid type
material laws. ICPRE = VAR is the default value and ICPRE = OFF will not reduce pressure
integration.
13. HEPH (ISOLID = 24) elements: This element uses an hourglass formulation similar to QEPH
shell elements.
14. ICPRE = VAR is only available for elasto-plastic material law.
15. The hourglass formulation is viscous for ISOLID = 0, 1, and 2.
16. Hourglass viscosity coefficient HV is not active with 8 point integration.

Altair Engineering

OptiStruct 13.0 Reference Guide 1909


Proprietary Information of Altair Engineering

17. It is recommended to use IHKT=2 (ISOLID=24) and Lagrange type total strain, ISMSTR=10
for foam or rubber materials, like MATX42 and MATX82. For elasto-plastic type material,
IHKT=2 will have a tighter yield stress criterion for an hourglass stress computation.
18. This card is represented as an extension to a PSOLID property in HyperMesh.

1910 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTADD
Bulk Data Entry
PTADD Pretension Load Combination (Superposition)
Description
Defines a pretension load as a linear combination of load sets defined via PTFORCE, PTFORC1,
PTADJST and PTADJS1 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PTADD

PSID

S1

L1

S2

L2

S3

L3

S4

L4

(10)

-etc-

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

PTADD

2.0

3.0

2.0

Field

Contents

PSID

Pretensioning load set identification number.

Scale factor. (See comment 1)

(8)

(9)

(10)

No default (Real)
Si

Scale factor. (See comment 1)


No default (Real)

Li

Pretension load set identification number defined via entry types


enumerated above. (See comment 1)
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1911


Proprietary Information of Altair Engineering

Comments
1. The pretension load as a linear combination is defined by:

Where,
S and Si are the scale factors.
Li is the pretension load set defined via PTFORCE, PTFORC1, PTADJST andPTADJS1
entries.

1912 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTADJS1
Bulk Data Entry
PTADJS1 Pretension Adjustment Definition, Alternate Form
Description
Defines adjustment (additional shortening) on a set of pretension sections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PTADJS1

PSID

ADJ

SID1

SID2

SID3

SID4

SID5

SID6

SID7

SID8

SID9

-etc-

Example

(1)

(2)

(3)

(4)

(5)

(6)

PTADJS1

0.05

(7)

Field

Contents

PSID

Pretensioning load set identification number.

(8)

(9)

(10)

(Integer > 0)
ADJ

Adjustment applied on this section (positive value means shortening).


See comment 2.
(Real)

SIDi

Pretension section identification number.


(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1913


Proprietary Information of Altair Engineering

Comments
1.

PTADJS1 can be referred by PTADD or by the PRETENSION command in the subcase


directly.

2.

Pretensioning adjustment shortens the pretensioned bolt by removing the prescribed


amount of material. This represents the effect of turning the nut by a prescribed
distance (number of turns).

3.

Pretensioning adjustment is an additional shortening applied to a pretension section. This


means that, when adjustment is applied to a section that has already been pretensioned,
the final effect will be a sum of the status reached in the preceding pretensioning
subcase plus the amount of ADJ.

1914 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTADJST
Bulk Data Entry
PTADJST Pretensioning Adjustment
Description
PTADJST defines the adjustment (shortening) on a pretension section.
Format
(1)

(2)

(3)

(4)

(5)

PTADJST

PSID

SID

ADJ

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

PTADJST

0.5

(5)

(6)

(7)

Field

Contents

PSID

Pretensioning load set identification number.

(8)

(9)

(10)

(Integer > 0)
SID

Pretension section identification number.


(Integer > 0)

ADJ

Adjustment applied on this section (positive value means shortening).


See comment 2.
(Real)

Comments
1.

PTADJST can be referred by PTADD or by the PRETENSION command in the subcase


directly.

Altair Engineering

OptiStruct 13.0 Reference Guide 1915


Proprietary Information of Altair Engineering

2.

Pretensioning adjustment shortens the pretensioned bolt by removing the prescribed


amount of material. This represents the effect of turning the nut by a prescribed
distance (number of turns).

3.

Pretensioning adjustment using PTADJST can also be used to define additional shortening
to a pretensioned section. Therefore, when adjustment is applied to a section that has
already been pretensioned, the final effect will be a sum of the status reached in the
preceding pretensioning subcase plus the amount of adjustment through PTADJST.

1916 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTFORCE
Bulk Data Entry
PTFORCE Pretensioning Force
Description
Defines pretensioning force on pretension section.
Format
(1)

(2)

(3)

(4)

PTFORC E

PSID

SID

(5)

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

PTFORC E

0.5

(5)

(6)

(7)

Field

Contents

PSID

Pretensioning load set identification number.

(8)

(9)

(10)

(Integer > 0)
SID

Pretension section identification number.


(Integer > 0)

Pretensioning force applied on this section. (Positive value creates


tension). See comment 2.
(Real)

Comments
1.

PTFORCE can be referred by PTADD or by the PRETENSION command in the subcase


directly.

Altair Engineering

OptiStruct 13.0 Reference Guide 1917


Proprietary Information of Altair Engineering

2.

Pretensioning force is actually a pair of forces, applied to the opposite sides of the
pretension section. This represents the effect of tightening the nut by a prescribed
longitudinal force (which is related to the applied torque).

1918 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTFORC1
Bulk Data Entry
PTFORC1 Pretensioning Force Definition, Alternate Form
Description
Defines pretensioning force on a set of pretension sections.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

PTFORC 1

PSID

SID1

SID2

SID3

SID4

SID5

SID6

SID7

SID8

SID9

-etc-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

PTFORC 1

500.0

(7)

Field

Contents

PSID

Pretensioning load set identification number.

(8)

(9)

(10)

(Integer > 0)
F

Pretensioning force applied on this set of sections. (Positive value


creates tension). See comment 2.
(Real)

SIDi

Pretension section identification number.


(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1919


Proprietary Information of Altair Engineering

Comments
1. PTFORC1 can be referred by PTADD or by the PRETENSION command in the subcase
directly.
2. Pretensioning force is actually a pair of forces, applied to the opposite sides of the
pretension section. This represents the effect of tightening the nut by a prescribed
longitudinal force (which is related to the applied torque).

1920 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PTUBE
Bulk Data Entry
PTUBE Tube Property
Description
PTUBE defines the properties of a thin-walled cylindrical tube element, referenced by a CTUBE
entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

PTUBE

PID

MID

OD

NSM

OD2

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

PTUBE

6.29

0.25

Field

Contents

PID

Unique identification number.

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
MID

Material identification number.


(Integer > 0)

OD

Outside diameter of tube.


(Real > 0.0)

Thickness of tube.
(Real; T < OD)

Altair Engineering

OptiStruct 13.0 Reference Guide 1921


Proprietary Information of Altair Engineering

Field

Contents

NSM

Nonstructural mass per unit length.


(Real)

OD2

Diameter of tube at second grid point G2 on CTUBE entry. See comment


4.
Default = OD (OD or blank)

Comments
1.

If T is zero, a solid circular rod is assumed.

2.

All PTUBE entries must have unique property identification numbers.

3.

For structural problems, PTUBE entries may only reference MAT1 material entries.

4.

Tapered tubes are not allowed.

5.

PTUBE data is converted to PROD data as it is read. CTUBE data is converted to CROD
data.

6.

This card is represented as a property in HyperMesh.

1922 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PVISC
Bulk Data Entry
PVISC Viscous Damping Element Property
Description
Defines properties of a one-dimensional viscous damping element (CVISC entry).
Format
(1)

(2)

(3)

(4)

(5)

PVISC

PID1

C E1

C R1

(6)

(7)

(8)

(9)

PID2

C E2

C R2

(10)

Example

(1)

(2)

(3)

(4)

PVISC

6.2

3.94

(5)

Field

Contents

PID#

Property identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


CE1, CE2

Viscous damping values for extension in units of force per unit


velocity.
No default (Real)

CR1, CR2

Viscous damping values for rotation in units of force per unit velocity.
No default (Real)

Comments
1.

Viscous properties are material independent; in particular, they are temperature


independent.

Altair Engineering

OptiStruct 13.0 Reference Guide 1923


Proprietary Information of Altair Engineering

2.

One or two viscous element properties may be defined on a single entry.

3.

This card is represented as a property in HyperMesh.

1924 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PWELD
Bulk Data Entry
PWELD WELD Element Property
Description
Defines properties of connector (CWELD) elements.
Format
(1)

(2)

(3)

(4)

PWELD

PID

MID

(5)

(6)

(7)

(8)

(9)

MSET

(10)

TYPE

Example

(1)

(2)

(3)

(4)

PWELD

30

2.5

(5)

Field

Contents

PID

Property identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


MID

Material identification number. See comment 1.


No default (Integer > 0)

Diameter of the connector. See comment 1.


No default (Real > 0.0)

MSET

Flag to eliminate m-set degrees-of-freedom. See comment 2.


Default = OFF (ON or OFF)

Altair Engineering

OptiStruct 13.0 Reference Guide 1925


Proprietary Information of Altair Engineering

Field

Contents

TYPE

Indicates type of connection. See comment 3.


SPOT indicates spot weld connector.
blank indicates general connector.
Default = blank (SPOT or blank)

Comments
1.

Material MID, diameter D, and the length are used to calculate the stiffness of the
connector in 6 directions. MID can only refer to the MAT1 bulk data entry. The length is
the distance of GA to GB (see below).

Length and Diameter of Weld connector

2.

MSET = ON generates explicit m-set constraints. MSET = OFF (default) incorporates


constraints at the element stiffness matrix level avoiding explicit m-set constraint
equations. The exact same results will be obtained regardless of this choice.

3.

If TYPE="SPOT" and if the formats PARTPAT, ELPAT, or ELEMID on the CWELD entry are
used, then the effective length for the stiffness of the CWELD element is set to
regardless of the distance GA to GB. t A and t B are the shell thicknesses of
shell A and B respectively. For all other cases, the effective length of the CWELD
element is equal to the true length, the distance of GA and GB, as long as the ratio of

1926 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

length to diameter is in the range 0.2 < L/D 5.0. If L is below the range, the effective
length is set to Le = 0.2D and if L is above the range, the effective length is set to Le =
5.0D.
4.

This card is represented as a property in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1927


Proprietary Information of Altair Engineering

QBDY1
Bulk Data Entry
QBDY1 Heat Flux Boundary Condition (Form 1)
Description
Defines a uniform heat flux for CHBDYE elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

QBDY1

SID

Q0

EID1

EID2

EID3

EID4

EID5

EID6

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

(5)

(6)

QBDY1

SID

Q0

EID1

THRU

EID2

Field

Contents

SID

Load set identification number.

(10)

No default (Integer > 0)


Q0

Heat flux into element.


No default (Real)

EID#

CHBDYE surface element identification numbers. With alternate format using


THRU EID2 > EID1.

Comments
1.

QBDY1 entries must be selected with the Case Control command LOAD=SID in order to be
used in static analysis. The total power into an element is given by the equation:

2.

The sign convention for Q0 is positive for heat input.

1928 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

This card is represented as a flux load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1929


Proprietary Information of Altair Engineering

QVOL
Bulk Data Entry
QVOL Volume Heat Addition
Description
Defines a rate of volumetric heat addition in a conduction element.
Format
(1)

(2)

(3)

QVOL

SID

QVOL

EID6

...

(4)

...

(5)

(6)

(7)

(8)

(9)

EID1

EID2

EID3

EID4

EID5

...

...

...

...

...

(10)

...

Field
SID

Contents
Load set identification number.
No default (Integer > 0)

QVOL

Power input per unit volume produced by a heat conduction element.


No default (Real)

EID#

A list of heat conduction elements.


No default (Integer > 0 or THRU or BY)

Comments
1.

EID# has material properties (MAT4/MAT5) that include HGEN, the scale factor for
volumetric heat generation. This association is made through the element EID.

2.

QVOL provides the constant volumetric heat generation rate. QVOL is positive for heat
generation. For steady-state analysis, the total power into an element is:

Where, HGEN is the scale factor from the MAT4 and MAT5 data.

1930 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

For use in steady-state analysis, the load set is selected with the Case Control command
LOAD=SID.

4.

This card is represented as a flux load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1931


Proprietary Information of Altair Engineering

RADPRM
Bulk Data Entry
RADPRM Parameters definition entry for Geometric Nonlinear Analysis
Description
Defines the parameters for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

RADPRM

PARAM1

VALUE1

PARAM5

VALUE5

(5)

(6)

PARAM2 VALUE2 PARAM3

(7)

(8)

(9)

(10)

VALUE3

PARAM4

VALUE4

Example

(1)

(2)

(3)

(4)

(5)

RADPRM

HMNAME

YES

RBE2RBD

YES

(6)

(7)

Field

Contents

PARAMi

Name of parameter. See below for allowable names.

VALi

Value of parameter.

(8)

(9)

(10)

The available parameters and their values are listed below (click the parameter name for
detailed parameter descriptions).

Parameter

Brief Description

Value

HMNAME

RADPRM, HMNAME controls the conversion of the YES or NO


component, property and material names in
Default = NO
geometric nonlinear analysis.

RBE2RBD

RBE2 is converted to /RBE2 by default in


YES or NO
geometric nonlinear analysis. This parameter can

1932 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Parameter

Brief Description

Value

be used to convert RBE2 to /RBODY, instead of / Default = NO


RBE2.
Comments
1.

The parameters defined by RADPRM bulk card are only applied in geometric nonlinear
analysis subcases which are defined by ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is
ignored for all other subcases.

Altair Engineering

OptiStruct 13.0 Reference Guide 1933


Proprietary Information of Altair Engineering

RADPRM, HMNAME
Parameter
HMNAME

Values

Description

YES or NO
Default = NO

RADPRM, HMNAME controls the conversion of


the component, property and material names in
geometric nonlinear analysis.
If YES, the converter will keep the component,
property and material names defined by
HyperMesh comments in the bulk model file, and
print them in a RADIOSS Starter file.
If NO, the converter will print intermediate
names automatically.

1934 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RADPRM, RBE2RBD
Parameter
RBE2RBD

Values

Description

YES or NO
Default = NO

RBE2 is converted to /RBE2 by default in


geometric nonlinear analysis. This parameter
can be used to convert RBE2 to /RBODY,
instead of /RBE2.
Note
RBE2 can be converted to /RBODY only if all six
degrees of freedom of the slave nodes are
dependent on the master node. Otherwise, the
solver errors out when RBE2RBD = YES. Note
that if the master node of the RBE2 is
connected to other elements or in the case of
hierarchical RBE2s, RADPRM, RBE2RBD activation
is not recommended.

Altair Engineering

OptiStruct 13.0 Reference Guide 1935


Proprietary Information of Altair Engineering

RADSND
Bulk Data Entry
RADSND Defines Grids (microphone locations) where sound levels will be calculated and the
locations of the corresponding source (vibrating panel) grids.
Description
Defines a set of grid points where the sound will be calculated as well as the panels that are
generating the sound.
Format
(1)

(2)

(3)

RADSND

RSID

MSET

"PANEL"

PID

(4)

(5)

(6)

(7)

PID

PID

- etc. -

(8)

(9)

(10)

Example

(1)

(2)

(3)

RADSND

10

100

PANEL

101

(4)

(5)

(6)

(7)

(8)

(9)

(10)

103

Field

Contents

RSID

Radiated sound set ID.


No default (Integer > 0)

MSET

ID of a SET of field grids (microphone locations) at which sound levels


will be calculated. The sound levels output at these grid points are due
to panel vibrations (specified separately in the PANEL and PIDi fields,
see comment 4).
No default (Integer > 0)

PANEL

Flag indicating that the following panel IDs will contribute to the sound
at the MSET grids (see comment 4).

1936 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Character (No default)

PIDi

Panel ID of the "PANELG" data entry of type "SOUND" data.


No default (Integer > 0)

Comments
1.

At least the first panel ID is required.

2.

Multiple continuations or multiple RADSND with the same SID are allowed if more than 7
SOUND panels need to be defined.

3.

The RADSND bulk data entry is referenced by the RADSND command in the Subcase
Information section of the input data.

4.

The MSET and PIDi fields are used to specify the microphone locations (receiving grids)
and the vibrating panels (source grids) respectively.
RADSND data entry field
MSET

Description
References microphone grid sets (receiving grids).
Outputs are generally calculated at these locations.

PANEL, PIDi

Reference vibrating panel IDs (source grids).


Outputs can also be requested at these locations.

Altair Engineering

OptiStruct 13.0 Reference Guide 1937


Proprietary Information of Altair Engineering

RANDPS
Bulk Data Entry
RANDPS Power Spectral Density Specification
Description
Defines load set power spectral density factors for use in random analysis having the
frequency dependent form S (F) = (X + iY) G(F).

jk

Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

RANDPS

SID

TID

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

RANDPS

2.0

2.5

Field

Contents

SID

Random analysis set identification number.

(8)

(9)

(10)

(Integer > 0)
J

Subcase identification number of excited load set.


(Integer > 0)

Subcase identification number of applied load set.


(Integer > 0; K > J)

X, Y

Components of complex number.


(Real)

1938 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

TID

Identification number of a TABRNDi entry which defines G(F).


Integer > 0

Comments
1.

If J = K, then Y must be 0.0.

2.

For TID = 0, G(F) = 1.0.

3.

Set identification number must be selected in the Subcase Information section (RANDOM
= SID) to activate the RANDPS data.

Altair Engineering

OptiStruct 13.0 Reference Guide 1939


Proprietary Information of Altair Engineering

RANDT1
Bulk Data Entry
RANDT1 Autocorrelation Function Time Lag
Description
Defines time lag constants for use in random analysis autocorrelation function computation.
Format
(1)

(2)

(3)

(4)

(5)

(6)

RANDT1

SID

T0

TMAX

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

RANDT1

10

3.2

9.6

(6)

(7)

Field

Contents

SID

Random analysis set identification number.

(8)

(9)

(10)

(Integer > 0)
N

Number of time lag intervals.


(Integer > 0)

TO

Starting time lag.


(Real > 0.0)

TMAX

Maximum time lag.


(Real > TO)

1940 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

At least one RANDPS entry must be present with the same set identification number.

2.

The time lags defined on this entry are given by

3.

Time lag sets must be selected in the Subcase Information section (RANDOM = SID) to
activate the RANDT1 data.

Altair Engineering

OptiStruct 13.0 Reference Guide 1941


Proprietary Information of Altair Engineering

RBAR
Bulk Data Entry
RBAR Rigid Bar
Description
Defines a rigid bar with six degrees-of-freedom at each end.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RBAR

EID

GA

GB

C NA

C NB

C MA

C MB

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

RBAR

234

123

(7)

Field

Contents

EID

Unique element identification number.

GA,GB

Grid point identification number of connection points.

(8)

(9)

(10)

(Integer > 0 or <PartName.number>) See comment 6.


CNA,CNB

Independent degrees-of-freedom in the global coordinate system for the


element at grid points GA and GB. Up to six unique digits (0 < digit < 6)
may be placed in each field with no embedded blanks, or the field may be
left blank. See comment 1.

CMA,CMB

Component numbers of dependent degrees-of-freedom in the global


coordinate system assigned by the element at grid points GA and GB. Up
to six unique digits (0 < digit < 6) may be placed in each field with no
embedded blanks, or the field may be left blank. See comment 2.

1942 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The total number of components in CNA and CNB must equal six, for example, CNA =
1236, CNB = 34. Furthermore, they must jointly be capable of representing any general
rigid body motion of the element.

2.

If both CMA and CMB are zero or blank, all of the degrees-of-freedom not in CNA and CNB
are made dependent.

3.

The degree of freedom declared dependent on this entry may not be:
Included in a single point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any other RBAR, RBE1, RBE2, RBE3, or
RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced by a subcase.

4.

Element identification numbers must be unique.

5.

Rigid elements are ignored in heat transfer analysis.

6.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on RBAR entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

7.

This card is represented as a weld element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1943


Proprietary Information of Altair Engineering

RBE1
Bulk Data Entry
RBE1 Rigid Body Element, Form 1
Description
Defines a rigid body connected to an arbitrary number of grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

RBE1

EID

GN1

C N1

GN2

C N2

GN3

C N3

GN4

C N4

GN5

C N5

GN6

C N6

GM1

C M1

GM2

C M2

GM3

C M3

GM4

C M4

GM5

C M5

etc.

"UM"

(9)

(10)

Example

(1)

(2)

(3)

(4)

RBE1

14

100

123456

UM

101

123

(5)

(6)

102

123

Field

Contents

EID

Unique element identification number.

(7)

(8)

(9)

(10)

No default (Integer)
GNi

Grid points at which independent degrees-of-freedom for the element are


assigned.
No default (Integer or <PartName.number>) See comment 7.

1944 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

CNi

Independent degrees-of-freedom in the global coordinate system for the


rigid element at grid point(s) GNi.

UM

UM flag indicating the start of the dependent degrees-of-freedom.

GMi

Grid points at which dependent degrees-of-freedom for the element are


assigned.
No default (Integer or <PartName.number>) See comment 7.

CMi

Dependent degrees-of-freedom in the global coordinate system for the


rigid elements at grid point(s) GMi.
No default (Integers 1 through 6 with no embedded blanks)

Comments
1.

The total number of components in CN1 to CN6 must equal six; furthermore, they must
jointly be capable of representing and general rigid body motion of the element. The first
continuation entry is not required if there are fewer than four GN points.

2.

The degree-of-freedom declared dependent on this entry may not be:


Included in a single point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any other RBAR, RBE1, RBE2, RBE3, or
RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced by a subcase.

3.

A degree-of-freedom cannot be both independent and dependent for the same element.
However, both independent and dependent components can exist at the same grid point.

4.

Element identification numbers must be unique.

5.

Rigid elements, unlike MPCs, may not be selected for use in individual subcases; they
apply to all subcases.

6.

Rigid elements are ignored in heat transfer analysis.

7.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on RBE1 entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

Altair Engineering

OptiStruct 13.0 Reference Guide 1945


Proprietary Information of Altair Engineering

RBE2
Bulk Data Entry
RBE2 Rigid Body Element, Form 2
Description
Defines a rigid body whose independent degrees-of-freedom are specified at a single grid point
and whose dependent degrees-of-freedom are specified at an arbitrary number of grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RBE2

EID

GN

CM

GM1

GM2

GM3

GM4

GM5

GM6

GM7

GM8

-etc.-

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RBE2

12

10

12

14

15

16

(10)

20

Field

Contents

EID

Unique element identification number.

GN

The grid point to which all six independent degrees-of-freedom for the
element are assigned.
(Integer > 0 or <PartName.number>) See comment 5.

CM

Component number of the dependent degrees of freedom in the global


coordinate system (local output coordinate system) at grid points GM1,
GM2, and so on. Up to six unique digits (1 < digit < 6) may be placed in
the field with no embedded blanks.

1946 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

GM1,GM2, etc. Grid points at which dependent degrees-of-freedom are assigned.


(Integer > 0 or <PartName.number>) See comment 5.
Comments
1.

The components indicated by CM are made dependent at all grid points, GMi.

2.

The degree-of-freedom declared dependent on this entry may not be:


Included in a single point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any other RBAR, RBE1, RBE2, RBE3, or
RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced by a subcase.

3.

Element identification numbers must be unique.

4.

Rigid elements are ignored in heat transfer analysis.

5.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on RBE2 entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

6.

This card is represented as a rigid or rigidlink element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1947


Proprietary Information of Altair Engineering

RBE3
Bulk Data Entry
RBE3 Interpolation Constraint Element
Description
Defines the motion at a "reference" grid point as the weighted average of the motions at a set
of other grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RBE3

EID

blank

REFGRID

REFC

WT1

C1

G1,1

G1,2

G1,3

WT2

C2

G2,1

G2,2

etc.

WT3

C3

G3,1

G3,2

etc.

WT4

C4

G4,1

G4,2

etc.

"UM"

GM1

C M1

GM2

C M2

GM3

C M3

blank

blank

GM4

C M4

GM5

C M5

etc.

blank

Example

(1)

(2)

RBE3

14

(3)

(4)

(5)

(6)

(7)

(8)

(9)

100

1234

1.0

123

4.7

5.2

5.1

15

16

UM

15

123

13

1948 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

Altair Engineering

Field

Contents

EID

Unique element identification number.

REFGRID

Reference grid point. This is the dependent GRID. Some, or all, of the
dependent degrees-of-freedom of this grid can be made independent by
redefining all of the dependent degrees-of-freedom following the UM flag.
(Integer > 0 or <PartName.number>) See comment 9.

REFC

Global components of motion whose values will be computed at the reference


grid point. Any of the digits 1, 2, ..., 6 with no embedded blanks.
(Integer > 0)

WTi

Weighting factor for components of motion on the following entry at grid points
Gi,j.
(Real)

Ci

Global components of motion that have weighting factor WTi, at grid points Gi,j.
Any of the digits 1, 2, ..., 6, with no embedded blanks.
(Integer > 0)

Gi,j

Grid point whose components Ci have weighting factor WTi in the averaging
equations.
(Integer > 0 or <PartName.number>) See comment 9.

UM

Optional flag indicating that a data set redefining the entire dependent degreeof-freedom set is to follow. The default is that all of the components in REFC at
the reference grid point form the dependent degree-of-freedom set. See
comments 4, 5 and 6.

GMi

Grid points with components in the redefined dependent degree-of-freedom set.


(Integer > 0 or <PartName.number>) See comment 9.

CMi

Components of motion at GMi in the redefined dependent degree-of-freedom set.


Any of the digits 1 through 6, with no embedded blanks.
(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1949


Proprietary Information of Altair Engineering

Comments
1.

It is recommended that for most applications only the translation components 123 be
used for Ci. An exception is the case where the Gij are collinear. A rotation component
may then be added to one grid point, to stabilize its associated rigid body mode for the
element.

2.

Blank spaces may be left at the end of a Gij sequence.

3.

The default for the dependent degree-of-freedom set should be used except in cases
where you want to redefine some or all REFC components as the dependent degree-offreedom set. If the default is not used for the dependent degree-of-freedom set:
The total number of components therein (that is, the total number of dependent
degrees-of-freedom defined by the element) must be equal to the number of
components in REFC (four components in the example).
The components therein must be a subset of the components mentioned in REFC and
Gij_Ci.
The coefficient matrix [Rm] in the constraints equation [RM] {um} + [Rn] {un} = 0
must be nonsingular, where um denotes the dependent degree-of-freedom set and un
denotes the independent degree-of-freedom set.

4. When the AMSES or AMLS eigenvalue solver is used, the UM data should be used when
loaded RBE3 have more than 500 DOF. Large loaded RBE3 will dramatically increase the
run times for AMSES or AMLS because the residual vectors will contain many DOF, unless
the UM data is used to make the loaded center GRID independent. When UM data is used,
the stiffness matrix becomes full for all the independent DOF of the RBE3, which can
increase the run time for very large RBE3. The number of grids can be reduced using a
HyperMesh macro. The macro is listed as Script 1068 in the Altair HyperWorks Script
Exchange:
www.altairhyperworks.com
5. UM data should not be used on large unloaded RBE3, as this will lead to an increase in the
run time.
6. Dependent degrees-of-freedom assigned by one rigid element may not also be assigned
dependent by another rigid element or by a multi-point constraint, and may not be
specified on SPC data.
7. In version 5.0, the RBE3 element calculation was modified in order to make the results
independent of the units used in the model. For this purpose, the weights of the
rotational degrees-of-freedom have been scaled by the square of the average distance
between the independent grid points and the reference point. This change will only affect
the results if independent grid points with rotational degrees-of-freedom exist in the RBE3
element. The previous RBE3 formulation can be enforced with the debug statement
debug, OLDRBE3,1.0.
8. Rigid elements are ignored in heat transfer analysis.
9. Supported local entries in specific parts can be referenced by the use of fully qualified
references on RBE3 entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry

1950 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.
10. This card is represented as an rbe3 element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1951


Proprietary Information of Altair Engineering

RCROSS
Bulk Data Entry
RCROSS Cross-Power Spectral Density Functions Output
Description
Defines a pair of response quantities for computing the cross-power spectral density functions
in random response analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RC ROSS

SID

RTYPE1

ID1

C OMP1

RTYPE2

ID2

C OMP2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RC ROSS

20

DISP

50

STRESS

150

Field

Contents

SID

RCROSS set identification number.

(10)

No default (Integer > 0)


RTYPE#

Type of response quantity. At least one field must be selected. If


either RTYPE1 or RTYPE2 is blank, then the blank field takes the
default from the defined field. See comment 2.

ID#

Element, grid, or scalar point identification number.


No default (Integer > 0)

COMP#

Component code (item) identification number. See comment 3.


No default (Integer > 0)

1952 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

This entry is required for computing the cross-power spectral density function. SID must
be selected with the I/O Option RCROSS. Fields RTYPE1, ID1, and COMP1 represent the
first response quantity and fields RTYPE2, ID2, and COMP2 represent the second response
quantity.

2.

The keywords for field RTYPE# are listed as follows:

3.

Keyword

Description

DISP

Displacement vector

VELO

Velocity vector

ACCEL

Acceleration vector

STRESS

Element Stress

STRAIN

Element Strain

For elements, COMP# represents a component of the element stress or strain as


described in the following table.
Element

Stress/Strain Item

Number code

All Solid Elements

Normal X

6 or 12

Normal Y

7 or 13

Normal Z

8 or 14

Shear XY

9 or 15

Shear YZ

10 or 16

Shear XZ

11 or 17

Normal X at Z1

3 or 4

Normal X at Z2

10 or 11

Normal Y at Z1

5 or 6

Normal Y at Z2

12 or 13

Shear XY at Z1

7 or 8

All Shell Elements

Altair Engineering

OptiStruct 13.0 Reference Guide 1953


Proprietary Information of Altair Engineering

Element

Stress/Strain Item

Number code

Shear XY at Z2

14 or 15

For grid points, COMP# represents a component of the displacement, velocity or


acceleration as described in the following table:
Response

Number code

Translation X

1 or 7

Translation Y

2 or 8

Translation Z

3 or 9

Rotation X

4 or 10

Rotation Y

5 or 11

Rotation Z

6 or 12

For scalar points, COMP# should always be 1.

1954 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RELOC
Bulk Data Entry
RELOC Grid Point Relocation
Description
The RELOC bulk data entry can be used to map grid points from one location to another. This
entry allows you to translate, match, rotate or mirror grid points. The grid ID fields can be
input as either numeric or fully qualified references to grid points in the model.
Format
The format of this entry depends on the TYPE field input; the various versions are listed as
follows:
Translation (TYPE = MOVE)
Format 1
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RELOC

ID

TYPE

GID1

GID2

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RELOC

ID

TYPE

dx

dy

dz

(8)

(9)

(10)

(10)

Format 2

Rotation (TYPE = ROTATE)


Format 1
(1)

(2)

(3)

(4)

(5)

(6)

(7)

RELOC

ID

TYPE

GID1

ang_x

ang_y

ang_z

Matching (TYPE = MATCH)


Format 1
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RELOC

ID

TYPE

GIDA1

GIDA2

GIDA3

GIDB1

GIDB2

GIDB3

Altair Engineering

OptiStruct 13.0 Reference Guide 1955


Proprietary Information of Altair Engineering

Mirroring (TYPE = MIRROR)


Format 1
(1)

(2)

(3)

(4)

(5)

(6)

(7)

RELOC

ID

TYPE

GIDA1

GIDA2

GIDA3

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RELOC

MATC H

1001

1012

3992

123

564

665

Field

Contents

ID

Set identification number.

(10)

(Integer > 0)
TYPE

This field specifies the type of mapping between grid points in a model. The
format of the RELOC card is different for different values of the TYPE field (see
Comment 2 for detailed information on each option).
(MOVE, ROTATE, MATCH, or MIRROR)

Translation (Format 1)
GID1

Grid point identification number for translation to the reference point location.
Grid point GID1 is moved from its original location to the GID2 location.
(Integer > 0 or <PartName.number>) See comment 4.

GID2

Reference grid point identification number for translation. GID2 is used as a


reference point to move another grid point (GID1) from its original location to
the GID2 location.
(Integer > 0 or <PartName.number>) See comment 4.

Translation (Format 2)
dx, dy, dz

Defines the distance that the referenced part (INSTNCE entry) should be
translated in the basic coordinate system. Each entry specifies the
corresponding distance moved in the X, Y, and Z axes, respectively (see
Comment 2).
(Real or blank)

1956 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Rotation (Format 1)
GID1

Specifies the identification number of a grid point that will be used as a center
of rotation based on the angles specified in the following fields.
(Integer > 0 or <PartName.number>) See comment 4.

ang_x,
ang_y,
ang_z

Defines the angle (in degrees) of rotation about the X, Y, and Z axes,
respectively with the grid point (GID1) as the center of rotation. In a 2D
model, only ang_z is specified (see Comment 2).
(Real or blank)

Matching (Format 1)
GIDA1,
GIDA2,
GIDA3

Specifies the identification numbers of grid points (initial location) that will be
moved to match with the corresponding grid points GIDB1,2,3 (final location,
defined in the following fields). Any rotation, translation or mirroring required
to complete this matching process is accomplished internally by OptiStruct.
These three grid points cannot be collinear.
(Integer > 0 or <PartName.number>) See comment 4.

GIDB1,
GIDB2,
GIDB3

Specifies the identification numbers of grid points which will be matched with
the corresponding grid points defined in the GIDA1,2,3 fields. Any rotation,
translation or mirroring required to complete this matching process is
accomplished internally by OptiStruct. These three grid points cannot be
collinear.
(Integer > 0 or <PartName.number>) See comment 4.

Mirroring (Format 1)
GIDA1,
GIDA2,
GIDA3

Specifies the identification numbers of grid points about which the entire part
(defined via INSTNCE) will be laterally mirrored (flipped) by 180 degrees. The
grid points GIDA1,2,3 define an absolute plane of symmetry flip. Any rotation
or translation required to complete this mirroring process is accomplished
internally by OptiStruct. The three grid points specified for mirroring cannot be
collinear. In a 2D model, only GIDA1 and GIDA2 should be specified.
(Integer > 0 or <PartName.number>) See comment 4.

Comments
1.

A RELOC entry can be referenced by a INSTNCE entry to define the location of a part in
the full model.

2.

The following illustrations depict part relocation examples for each of the four TYPE field
options. All grid point IDs used on the RELOC entry can belong to any part in the model.
Only their initial locations are relevant. All RELOC entries are evaluated before any parts

Altair Engineering

OptiStruct 13.0 Reference Guide 1957


Proprietary Information of Altair Engineering

are moved. This may not always produce the expected result in some cases as the
sequence of moves affects the final part locations. For example, if RELOC, MATCH is
defined using three grid points on part A and three grid points in part B, this may not
result in a final structure with the two parts being connected, if part B is moved again
after this matching process. To avoid such cases, it is strongly recommended to assign
the grid points that define the initial location to a part that has to be moved and the grid
points that define the final location, to a part that will not be moved (for example, the
global structure).
Translation - Format 1:

Format 1 (Special case, assumes that Part B does not relocate)

1958 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Translation - Format 2:

dx

dy

dz

Where,

D is the distance moved by the part referenced on the INSTNCE entry.


dx, dy and dz are the distances moved by the part along the X, Y and Z axes.
Rotation - Format 1:

Altair Engineering

OptiStruct 13.0 Reference Guide 1959


Proprietary Information of Altair Engineering

Matching - Format 1:

Format 1 (Special case Part B does not relocate)

1960 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Mirroring - Format 1:

3.

In a 2D model, only two TYPE options are allowed: ROTATE and MIRROR. All grid points in
the model should have the same Z coordinate. Rotation and mirroring are defined in the XY plane.
Rotation in a 2D model defined in the X-Y plane
(1)

(2)

(3)

(4)

RELOC

ID

ROTATE

GID1

(5)

(6)

(7)

(8)

(9)

(10)

(8)

(9)

(10)

ang_z

Mirroring in a 2D model defined in the X-Y plane

4.

(1)

(2)

(3)

(4)

(5)

RELOC

ID

MIRROR

GIDA1

GIDA2

(6)

(7)

Supported local entries in specific parts can be referenced by the use of fully qualified
references on RELOC entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN bulk data entry in the model). number is the identification number of a referenced
local entry in the part PartName. See Parts and Instances in the Users Guide for
detailed information on the use of fully qualified references.

Altair Engineering

OptiStruct 13.0 Reference Guide 1961


Proprietary Information of Altair Engineering

RFORCE
Bulk Data Entry
RFORCE Rotational Force
Description
Defines a static loading condition due to a centrifugal force field. It can also be used to define
the EXCITEID field (Amplitude A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2
bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

RFORC E

SID

C ID

R1

R2

R3

(9)

(10)

RAC C

Example

(1)

(2)

(3)

RFORC E

(4)

(5)

(6)

(7)

(8)

0.0

0.0

1.0

2.2

(9)

(10)

1.0

Field

Contents

SID

Load set identification number.


No default (Integer > 0)

Grid point identification number through which the rotation vector acts.
Default = 0 (Integer > 0)

CID

Coordinate system defining the components of the rotation vector.

1962 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 0 (Integer > 0)

Scale factor of the rotational velocity in revolutions per unit time.


Default = 0.0 (Real)

R1,R2,R3

Rectangular components of rotation direction vector. The vector defined


will pass through point G.
No default (Real; R12 + R22 + R32 > 0.0)

RACC

Scale factor of the rotational acceleration in revolutions per unit time


squared.
(Real)

Comments
1.

The rotational forces that are created with an RFORCE entry for a constant angular
velocity (A), act in the positive radial direction. They represent the initial forces on the
structure due to a constant angular velocity. The rotational forces defined for a
constant angular acceleration (RACC), act in the same direction as the angular
acceleration. They would be opposite to the inertia forces on the structure due to a
constant angular acceleration.
The following plot shows that the RFORCE vector at node Gi is given by:

where,
angular velocity =

angular acceleration =

Altair Engineering

OptiStruct 13.0 Reference Guide 1963


Proprietary Information of Altair Engineering

RFORC E vector at node Gi

2.

G = 0 or blank means the basic coordinate system origin.

3.

CID = 0 or blank signifies that the rotation vector acts at the origin of the basic
coordinate system.

4.

The RFORCE load is selected for use in a subcase by the Subcase Information entry LOAD.

5.

The load vector generated by this entry can be printed using the I/O Option OLOAD.

6.

The continuation line containing RACC is optional.

7.

For CONM1 and CONM2 entries, OptiStruct calculates the torque, due to rotation, as
follows:

where, I is the moment of inertia.


8.

This card is represented as a loadcollector in HyperMesh.

1964 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RGYRO
Bulk Data Entry
RGYRO Rotor Dynamics
Description
Bulk Data Entry for the inclusion of data required to perform Rotor Dynamics analysis in Modal
Frequency Response Analysis and/or Modal Complex Eigenvalue Analysis. The RGYRO Bulk Data
Entry is referenced by a corresponding RGYRO Subcase Information Entry in a specific
subcase.
Format
(1)

(2)

(3)

(4)

RGYRO

RID

SYNC FLG

(5)

REFROTR SPDUNIT

(6)

(7)

(8)

(9)

SPDLOW

SPDHIGH

SPEED

(10)

Example

(1)

(2)

(3)

(4)

(5)

RGYRO

14

ASYNC

FREQ

(6)

(7)

(8)

(9)

(10)

55

Argument

Options

Description

RID

<INTEGER>

setid:

The SID is referenced by a RGYRO card


in the subcase information section.

SYNCFLG

<SYNC, ASYNC >

SYNC:

Synchronous Rotor dynamic analysis is


selected, if SYNC is input in this field.

ASYNC:

Asynchronous Rotor dynamic analysis is


selected, if ASYNC is input in this field.

rotid:

Reference rotor ID. This field selects


the rotor that will be used in THE Rotor
dynamic analysis.

(no default)

REFROTR

<INTEGER > 0>

Altair Engineering

OptiStruct 13.0 Reference Guide 1965


Proprietary Information of Altair Engineering

Argument

Options

Description

(no default)

SPDUNIT

<RPM, FREQ>

RPM:

RPM specifies that the entries SPDLOW,


SPDHIGH and SPEED are input in
Revolutions Per Minute.

FREQ:

FREQ specifies that the entries


SPDLOW, SPDHIGH and SPEED are input
in revolutions per unit time.

(No default)

SPDLOW

<INTEGER>

Minimum rotor speed for synchronous analysis.

Default = 0.0

SPDHIGH

<INTEGER>

Maximum rotor speed for synchronous analysis.

Default = 99999.0

SPEED

<INTEGER, Real>

<INTEGER>

If an integer value is input, it references


a RSPEED bulk data entry that specifies
a set of reference rotor speeds for
asynchronous analysis (See comment
2).

<Real>

If a real number is input, the value is


considered constant and a single
reference rotor speed value is specified
(See comment 2).

Default = 0

Default = 0.0

Comments
1.

Multiple RGYRO bulk data entries with the same RID cannot exist.

2.

The values entered on some optional fields of the RGYRO bulk data entry depend on
factors such as: solution sequence used, type of analysis performed, and the value of
specific parameters. The following table shows some of the optional fields and their
relevance based on the listed factors. Synchronous analysis is performed when the rotor
speed is equal to the modal frequency (Complex eigenvalue analysis) or the frequency of
the forcing function (Frequency response analysis) and Asynchronous analysis is

1966 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

performed when the user specified rotor speed is used for the analysis.
Synchronous/
Solution Sequence Asynchronous
Analysis
Modal Frequency
Response Analysis

Modal Complex
Eigenvalue Analysis

3.

Required
Entry

PARAM,
GYROAVG

Comment

Synchronous

None

Synchronous

SPDLOW,
SPDHIGH

-1

3, 4

Asynchronous

SPEED

Asynchronous

SPEED

-1

Synchronous

SPDLOW,
SPDHIGH

3, 4

Asynchronous

SPEED

When multiple rotors are present within the system being modeled, one of the rotors is
chosen as a reference rotor. The speeds of the rest of the rotors are linearly dependent
of the reference rotor. Scale factors S1 and S2 are used to relate the speeds.

S1 S 2 *

ref

Where,
is the speed of a rotor (different from the reference rotor)
S1 and S2 are scale factors
ref

is the speed of the reference rotor

The scale factors S1 and S2 will be calculated by a least-mean-square fit of the relative
rotor speeds specified on the RSPINR entries (between SPDLOW to SPDHIGH of the
reference rotor). If the SPDLOW or SPDHIGH values are beyond the range specified on
the RSPINR entry, the values will be extrapolated from the RSPINR entry values.
4.

PARAM, WR3 and PARAM, WR4 are necessary for rotor damping.

Altair Engineering

OptiStruct 13.0 Reference Guide 1967


Proprietary Information of Altair Engineering

RLOAD1
Bulk Data Entry
RLOAD1 Frequency Response Dynamic Load, Form1
Description
Defines a frequency-dependent dynamic load of the form
for use in frequency response problems.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RLOAD1

SID

EXC ITEID

DELAY

DPHASE

TC

TD

TYPE

(10)

Example

(1)

(2)

(3)

RLOAD1

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Field

Contents

SID

Set identification number.


No default (Integer > 0)

EXCITEID

Identification number of the DAREA, SPCD, FORCEx, MOMENTx,


PLOADx, RFORCE, or GRAV entry set that defines A.
No default (Integer > 0)

DELAY

Defines time delay . If it is a non-zero integer, it represents the


identification number of a DELAY bulk data entry that defines . If
it is real, then it directly defines the value of
that will be used for
all degrees-of-freedom that are excited by this dynamic load entry.
Default = 0 (Integer > 0, or Real)

1968 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

DPHASE

Defines phase . If it is a non-zero integer, it represents the


identification number of a DPHASE bulk data entry that defines . If
it is real, then it directly defines the value of that will be used for
all degrees-of-freedom that are excited by this dynamic load entry.
Default = 0 (Integer > 0, or Real)

TC

Set identification number of the TABLED1, TABLED2, TABLED3 or


TABLED4 entry that gives C( ). See comment 2.
Default = 0 if TD is non-zero (Integer > 0)

TD

Set identification number of the TABLED1, TABLED2, TABLED3 or


TABLED4 entry that gives D( ). See comment 2.
Default = 0 if TC is non-zero (Integer > 0)

TYPE

Identifies the type of the dynamic excitation.


Default = 0 (See comment 5)

Comments
1.

Dynamic load sets must be selected in the I/O Options or Subcase Information sections
with the command DLOAD = SID.

2.

If any DELAY, DPHASE, TC, or TD fields are blank or zero, the corresponding , , C( ), or
D( ) will be zero. Either TC or TD may be blank or zero, but not both.

3.

RLOAD1 loads may be combined with RLOAD2 loads only by specification on a DLOAD
entry. This means that the SID on a RLOAD1 entry must not be the same as that on a
RLOAD2 entry.

4.

SID must be unique for all RLOAD1 and RLOAD2 entries.

5.

The type field identifies the type of dynamic excitation. Valid entries for this field are
listed alongside a description of the dynamic excitation with they invoke.
Type

Description

0, L, LO, LOA, LOAD

Applied load; EXCITEID references DAREA data.

1, D, DI, DIS, DISP

Enforced displacement; EXCITEID references SPCD data.

2, V, VE, VEL, VELO

Enforced velocity; EXCITEID references SPCD data.

Altair Engineering

OptiStruct 13.0 Reference Guide 1969


Proprietary Information of Altair Engineering

Type

Description

3, A, AC, ACC, ACCE

Enforced acceleration; EXCITEID references SPCD data.

6.

When EXCITEID refers to an SPCD entry, the modal space will be augmented with
displacement vector(s) from linear static analysis with unit prescribed displacement at
each of the SPCD degrees-of-freedom.

7.

All static structural loads can be referenced by EXCITEID by referring to the SID on the
structural load. The structural loads are FORCE, FORCE1, FORCE2, MOMENT, MOMENT1,
MOMENT2, PLOAD, PLOAD1, PLOAD2, PLOAD4, RFORCE, and GRAV. EXCITEID cannot
reference the LOAD and LOADADD Bulk Data entries.

8.

This card is represented as a loadcollector in HyperMesh.

1970 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RLOAD2
Bulk Data Entry
RLOAD2 Frequency Response Dynamic Load, Form 2
Description
Defines a frequency-dependent dynamic load of the form:

for use in frequency response problems.


Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RLOAD2

SID

EXC ITEID

DELAY

DPHASE

TB

TP

TYPE

(10)

Example

(1)

(2)

(3)

RLOAD2

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Field

Contents

SID

Set identification number.


No default (Integer > 0)

EXCITEID

Identification number of the DAREA, SPCD, FORCEx, MOMENTx,


PLOADx, RFORCE, or GRAV entry set that defines A.
No default (Integer > 0)

DELAY

Defines time delay . If it is a non-zero integer, it represents the


identification number of a DELAY bulk data entry that defines . If
it is real, then it directly defines the value of
that will be used for
all degrees-of-freedom that are excited by this dynamic load entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1971


Proprietary Information of Altair Engineering

Field

Contents
Default = 0 (Integer > 0, or Real)

DPHASE

Defines phase . If it is a non-zero integer, it represents the


identification number of a DPHASE bulk data entry that defines . If
it is real, then it directly defines the value of that will be used for
all degrees-of-freedom that are excited by this dynamic load entry.
Default = 0 (Integer > 0, or Real)

TB

Set identification number of the TABLED1, TABLED2, TABLED3 or


TABLED4 entry that gives B( ).
No default (Integer > 0)

TP

Set identification number of the TABLED1, TABLED2, TABLED3 or


TABLED4 entry that gives
in degrees.
Default = 0 (Integer > 0)

TYPE

Identifies the type of the dynamic excitation.


Default = 0 (See comment 5)

Comments
1.

Dynamic load sets must be selected in the I/O Options or Subcase Information sections
with the command DLOAD = SID.

2.

If any DELAY, DPHASE, or TP fields are blank or zero, the corresponding , , or


be zero.

3.

RLOAD2 loads may be combined with RLOAD1 loads only by specification on a DLOAD
entry. This means that the SID on a RLOAD2 entry must not be the same as that on a
RLOAD1 entry.

4.

SID must be unique for all RLOAD1 and RLOAD2 entries.

5.

The TYPE field identifies the type of dynamic excitation. Valid entries for this field are
listed below alongside a description of the dynamic excitation which they invoke.
Type

Description

0, L, LO, LOA, LOAD

Applied load; EXCITEID references DAREA data.

1, D, DI, DIS, DISP

Enforced displacement; EXCITEID references SPCD data.

1972 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

will

Altair Engineering

Type

Description

2, V, VE, VEL, VELO

Enforced velocity; EXCITEID references SPCD data.

3, A, AC, ACC, ACCE

Enforced acceleration; EXCITEID references SPCD data.

6.

When EXCITEID refers to an SPCD entry, the modal space will be augmented with
displacement vector(s) from linear static analysis with unit prescribed displacement at
each of the SPCD degrees-of-freedom.

7.

All static structural loads can be referenced by EXCITEID by referring to the SID on the
structural load. The structural loads are FORCE, FORCE1, FORCE2, MOMENT, MOMENT1,
MOMENT2, PLOAD, PLOAD1, PLOAD2, PLOAD4, RFORCE, and GRAV. EXCITEID cannot
reference the LOAD and LOADADD Bulk Data entries.

8.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1973


Proprietary Information of Altair Engineering

ROTORG
Bulk Data Entry
ROTORG Grids for the Rotor Line Model (Rotor Dynamics).
Description
This Bulk Data Entry is used for the specification of grids that determine the Rotor Line model.
Format
(1)

(2)

ROTORG ROTORID

(3)

(4)

(5)

(6)

GRID1

GRID2

GRIDn

(3)

(4)

(5)

(6)

GRID1

THRU

GRID2

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

ROTORG ROTORID

Example

(1)

(2)

(3)

(4)

(5)

(6)

ROTORG

25

2345

2356

2400

2450

(6)

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Example (Alternate Format)

(1)

(2)

(3)

(4)

(5)

ROTORG

30

2300

THRU

2400

Argument

Options

Description

ROTORID

<INTEGER > 0>

setid:

The identification number of a rotor.

1974 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

GRIDi

<INTEGER > 0>

List of grids that define the rotor line model.

No default

THRU
(Optional)

Flag indicating that a range of grid identification numbers is defined. The


initial and final grids are specified on the fields either side of the field
containing the THRU flag.

Comments
1.

All grid point entries specified on the ROTORG entry must be unique. The program will run
into an error, if duplicate grid entries are specified.

2.

Multiple ROTORG entries can be defined with the same ROTORID.

3.

This ROTORG entry is used to define a Rotor Line model; therefore, for a specific
ROTORID, all grids specified on the ROTORG entry must be collinear. OptiStruct
automatically checks if the grids are collinear during a run.

4.

If superelements are not used, connections between grids in the Rotor Line model and
those not listed on the ROTORG entry must be defined using MPCs or rigid elements.

5.

If superelements are used, connections between grids in the Rotor Line model and those
in the residual structure must be defined using MPCs or rigid elements.

6.

The mass of the Rotor Line model should be defined on the grids defined on the grids
specified by the ROTORG bulk data entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 1975


Proprietary Information of Altair Engineering

RROD
Bulk Data Entry
RROD Rigid Pin-Ended Rod
Description
Defines a pin-ended rod that is rigid in extension.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

RROD

EID

GA

GB

C MA

C MB

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

RROD

14

1115

(6)

(7)

(8)

Field

Contents

EID

Unique element identification number.

GA,GB

Grid point identification numbers of connection points.

(9)

(10)

(Integer > 0 or <PartName.number>) See comment 6.


CMA,CMB

Component number of one and only one dependent translational degreeof-freedom in the global coordinate system assigned by you to either
GA or GB. Integer equal to 1, 2, or 3, or blank. Either CMA or CMB
must contain the integer and the other must be blank.

Comments
1.

Element identification numbers must be unique.

2.

Forces of constraint are not recovered.

1976 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

The degree-of-freedom selected to be dependent must have a non-zero component along


the axis of the rod. This implies that the rod must have finite length.

4.

The degree-of-freedom declared dependent on this entry may not be:


Included in a single point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any other RBAR, RBE1, RBE2, RBE3, or
RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced by a subcase.

5.

Rigid elements are ignored in heat transfer analysis.

6.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on RROD entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

7.

This card is represented as a rod element in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1977


Proprietary Information of Altair Engineering

RSPEC
Bulk Data Entry
RSPEC Response Spectrum Analysis Specifications
Description
Specifies directional combination method, modal combination method, excitation direction(s),
response spectra and scale factors.
Format
(1)

(2)

(3)

(4)

(5)

(6)

RSPEC

RID

DC OMB

MC OMB

C LOSE

DTISPEC 1

SC ALE1

X11

X12

X13

DTISPEC 2

SC ALE2

X21

X22

X23

DTISPEC 3

SC ALE3

X31

X32

X33

(7)

(8)

(9)

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

RSPEC

35

ALG

SRSS

1.0

1.3

0.5

0.5

(1)

(2)

(3)

(4)

(5)

RSPEC

35

SRSS

C QC

0.0

(6)

(7)

(8)

(9)

(10)

-1.

Example 2

(6)

(7)

1978 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(8)

(9)

(10)

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

1.3

0.5

0.5

-1.

2.0

-2

-0.0

-1.

17.

0.5

-2.5

-1.

Field

Contents

RID

RSPEC identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


DCOMB

Method for directional combination. Can be either algebraic (ALG) or


square root of sum of squares (SRSS).
Default = ALG (ALG or SRSS)

MCOMB

Method for modal combination. Can be either absolute sum (ABS),


square root of sum of squares (SRSS), complete quadratic combination
(CQC), or Navy Reseach Laboratorys SRSS (NRL).
Default = ABS (ABS, SRSS, CQC, or NRL)

CLOSE

Modal frequency closeness parameter.


Default = 1.0 (Real)

DTISPECi

Response spectrum reference. ID of a DTI,SPECSEL entry.


No default (Integer > 0)

SCALEi

Scale factor for excitation.


No default (Real <> 0.0)

Xij

Components of a vector representing ground excitation i, j = 1..3

Comments
1.

All RSPEC cards must have unique ID numbers.

2.

DTISPEC2/SCALE2/X21/X22/X23 and DTISPEC3/SCALE3/X31/X32/X33 are optional ground


excitations for multi-directional excitation. The directions of excitation have to be
orthogonal to each other and will be reported as error otherwise.

3.

Refer to Response Spectrum Analysis in the Users Guide for more details.

Altair Engineering

OptiStruct 13.0 Reference Guide 1979


Proprietary Information of Altair Engineering

RSPEED
Bulk Data Entry
RSPEED Reference Rotor Speed Values
Description
This bulk data entry is used to specify a set of reference rotor speed values for asynchronous
analysis in Rotor Dynamics.
Format
(1)

(2)

(3)

(4)

(5)

(6)

RSPEED

SID

S1

DS

NDS

(7)

(8)

(9)

(10)

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

RSPEED

25

1500

50

(6)

Argument

Options

Description

SID

<Integer > 0>

Set identification number.

No default

S1

<Real > 0.0>

Specifies the first reference rotor speed in the set.

No default

DS

<Real > 0.0>


No default

Specifies the increment in reference rotor speed.


This value is added to each successive entry
starting from the first entry (S1).

1980 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

NDS

<Integer > 0>

Number of reference rotor speed increments.

Default = 1
Comments
1.

The RSPEED bulk data entry is referenced by the SPEED field on the RGYRO bulk data
entry. If an integer value is specified in the SPEED field, multiple reference rotor speeds
specified in the RSPEED entry are used in asynchronous analysis.

2.

In asynchronous frequency response analysis, if the RSPEED bulk data entry is referenced
in RGYRO, only the first frequency is considered. In complex eigenvalue analysis, the full
range specified by RSPEED is considered.

3.

The following formula is used to populate the set of reference rotor speeds:

Ri

( S1 ( DS ) * i)

i 1 to NDS

R1 , R2 , RNDS represent the set of reference rotor speeds


S1 is the first reference rotor speed
DS is the reference rotor speed increment
NDS is the number of reference rotor speed increments

Altair Engineering

OptiStruct 13.0 Reference Guide 1981


Proprietary Information of Altair Engineering

RSPINR
Bulk Data Entry
RSPINR Relative Rotor Spin Rates (Rotor Dynamics)
Description
This entry defines the relative spin rates between rotors during a rotor dynamic analysis in
Modal Complex Eigenvalue or Frequency Response solution sequences.
Format
(1)

(2)

(3)

(4)

(5)

(6)

SPINR

ROTORID

GRIDA

GRIDB

SPDUNIT

SPTID

GR

(7)

(8)

(9)

(10)

ALPHAR1 ALPHAR2

Example

(1)

(2)

(3)

(4)

(5)

(6)

RSPINR

130

2400

2401

FREQ

200

0.03

(7)

(8)

(9)

(10)

5600

Argument

Options

Description

ROTORID

<Integer > 0>

setid

Rotor identification number

No default

GRIDA

<Integer > 0>

GRIDA identifies a grid on the Rotor Line Model.

No default

GRIDA and GRIDB define the positive rotor spin


direction. The vector connecting GRIDA and GRIDB is
the positive direction vector. The rotor axis is
defined using the ROTORG bulk data entry and the
two grids (GRIDA, GRIDB) are also specified on the
ROTORG bulk data entry.

1982 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

GRIDB

<Integer > 0>

GRIDB identifies a grid on the Rotor Line Model.

No default

GRIDA and GRIDB define the positive rotor spin


direction. The vector connecting GRIDA and GRIDB is
the positive direction vector. The rotor axis is
defined using the ROTORG bulk data entry and the
two grids (GRIDA, GRIDB) are also specified on the
ROTORG bulk data entry.

<RPM, FREQ>

RPM:

RPM specifies that the relative spin


rates are input in Revolutions Per
Minute.

FREQ:

FREQ specifies that the relative spin


rates are input in revolutions
(cycles) per unit time.

SPDUNIT

Description

(No default)

SPTID

<Integer > 0/Real>


(No default)

<Integer > 0> If an integer value (must be greater


than 0) is input, it references a
DDVAL bulk data entry that specifies
the relative rotor spin rates (see
comment 3).
<Real>

GR

<Real>
Default = 0.0

ALPHAR1

<Real>
Default = 0.0

Altair Engineering

If a real number is input, the value is


considered constant.

Rotor Structural Damping Factor (see comments 4


and 6).

Scale factor applied to the rotor mass matrix for


Rayleigh Damping (see comments 5 and 6).

OptiStruct 13.0 Reference Guide 1983


Proprietary Information of Altair Engineering

Argument

Options

ALPHAR2

<Real>

Description

Scale factor applied to the rotor stiffness matrix for


Rayleigh Damping (see comments 5 and 6).

Default = 0.0
Comments
1.

A RSPINR entry must exist for each rotor line model defined using the ROTORG bulk data
entry.

2.

GRIDA and GRIDB define the positive rotor spin direction. The vector connecting GRIDA
and GRIDB is the positive direction vector. The rotor axis is defined using the ROTORG bulk
data entry and the two grids (GRIDA, GRIDB) are also specified on the ROTORG bulk data
entry.

3.

An integer or a real number can be input in the SPTID field. If SPTID is an integer, it
references a DDVAL bulk data entry that specifies the relative rotor spin rates. Each rotor
must be assigned the same number of spin rates. To determine relative spin rates, the
table entries which contain the sequence of spin rates are correlated. The ith entry for
each rotor corresponds to the relative spin rates between rotors at RPMi/FREQi. The spin
rates for the reference rotor must be specified in ascending or descending order.

4.

Rotor structural damping factor (GR) can be incorporated as either equivalent viscous
damping or structural damping depending on the solution sequence.

BRotor

structural

GR
WR3

K rotor

Or,

K rotor

(1 iGR ) K rotor

Where,

WR3 is a parameter defined by PARAM, WR3


GR is defined as a field on the RSPINR bulk data entry.
The selection depends on the following factors:
Modal frequency response or Complex eigenvalue analysis.
Synchronous or Asynchronous solutions.
Value of PARAM, GYROAVG.
5.

The Rayleigh damping value for the rotor is calculated as:

Brotor

Rayleigh

R1

( M rotor )

R2

(K rotor )

1984 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

The damping and circulation terms added to the corresponding analysis equations are
listed in the table below. Refer to the Rotor Dynamics section in the User's Guide for
detailed information.
Solution Sequence Analysis

Damping

i ([ BR ]

Frequency Response
(ASYNC)

Circulation

R1 [ M R ]

R 2 [ K R ])

i (GR[ K R ] [ K 4 R ])

[ BR ]
Frequency Response
(ASYNC + GYROAVG, -1)

Frequency Response
(SYNC)

i ([ BR ]

R1

[M R ]

R2

[ BRC ]
(

ref

GR

R1 [ M R ]

R 2 [ K R ])

i (GR[ K R ] [ K 4 R ])

Frequency Response
(SYNC + GYROAVG, -1)

Altair Engineering

[M R ]

GR
[KR ]
WR3

[ BR ]
Complex Eigenvalue
(ASYNC)

R1

R1

[M R ]

GR
[KR ]
WR3

R2

[KR ]

R1

GR

1
[ K 4 R[ B
] C]
R
WR 4
GR
R

R2

R1

GR

[ BRC ]
[ BR ]

[KR ]

R1

[ M RC ]

R1

(
)
1
[RK 4 Rref]
WR 4

[ M RC ]

R1

[ K RC ]

[ K 4CR ]

[ K RC ]

[ K RC ]

[ K 4CR ]

[ M RC ]

GR
[ K RC ]
WR3

[ K RC ]

[ K 4CR ]
R2

[ K RC ]

[ BRC ]

R2

[ K RC ]

R2

R2

[ M RC ]

[ K 4CR ]

1
[ K 4CR ]
WR 4

[ M RC ]

[ K RC ]

[ K RC ]

R2

GR
[ K RC ]
WR3

[ BRC ]
( )

[ M RC ]

[ K RC ]

[ BRC ]

[KR ]

1
R ( ref )
[ K 4R ]
WR 4

GR
[KR ]
WR3

R1

R2

[ K RC ]

1
[ K 4CR ]
WR 4

OptiStruct 13.0 Reference Guide 1985


Proprietary Information of Altair Engineering

Solution Sequence Analysis

Damping

Circulation

[ BRC ]
[ BR ]
Complex Eigenvalue
(SYNC)

R1

[M R ]

GR
[KR ]
WR3

R2

[KR ]

GR

1
[ K 4 R[ B
] C]
R
WR 4
GR
R

R1

[ M RC ]

[ K RC ]
R1

R2

[ M RC ]

[ K RC ]

[ K 4CR ]
R2

[ K RC ]

[ K RC ]

[ K 4CR ]

Where,

[ BR ]

is the rotor viscous damping

[M R ]

is the rotor mass

[K R ]

is the rotor stiffness

[ K 4R ]
C
R

[B ]

is the circulation, due to rotor viscous damping

C
R

[M ]
[ K RC ]
C
R

[K 4 ]
R1

is the rotor material damping

is the circulation, due to rotor mass


is the circulation, due to rotor structural stiffness
is the circulation, due to rotor material damping

and

R2

[ BR ]Rayleigh

are used to define the Rayleigh viscous damping, as follows:


R1

[M R ]

R2

[K R ]

WR3 and WR4 are defined by the parameters PARAM, WR3 and PARAM, WR4,
respectively.
7.

Rotor damping is cumulative and caution should be exercised when multiple damping
effects are assigned.

1986 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RSPLINE
Bulk Data Entry
RSPLINE Interpolation Constraint Element
Description
Defines multi-point constraints for the interpolation of displacements at grid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RSPLINE

EID

D/L

G1

G2

C2

G3

C3

G4

C4

G5

C5

G6

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

RSPLINE

73

0.05

27

28

123456

29

123

75

123

71

Field

Contents

EID

Unique element identification number.

(8)

(9)

(10)

30

No default (Integer > 0)


D/L

Ratio of the diameter of the elastic tube to the sum of the lengths of all
segments.
Default = 0.1 (Real > 0.0)

G#

Grid point identification number.


No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1987


Proprietary Information of Altair Engineering

Field

Contents

C#

Components to be constrained. See comment 2.


Default = blank (blank or any combination of the Integers 1 through 6)

Comments
1.

Displacements are interpolated from the equations of an elastic beam passing through the
grid points. This is a linear method only element.

2.

A blank field for C# indicates that all six degrees-of-freedom at G# are independent.
Since G1 must be independent, no field is provided for C1. Since the last grid point must
also be independent, the last field must be a G#, not a C#. For the example shown G1,
G3 and G6 are independent. G2 has six constrained degrees-of-freedom, while G4 and G5
each have three.

3.

Dependent (that is constrained) degrees-of-freedom assigned by one rigid element may


not also be assigned dependent by another rigid element or by a multi-point constraint.

4.

Degrees-of-freedom declared to be independent by one rigid body element can be made


dependent by another rigid body element or by a multi-point constraint.

5.

Rigid elements (including RSPLINE), unlike MPCs, form part of the model and do not need
to be selected from within a subcase definition.

6.

Rigid elements are ignored in heat transfer problems.

7.

The constraint coefficient matrix is affected by the order of the Gi Ci pairs on the RSPLINE
entry. The order of the pairs should be specified in the same order that they appear
along the line that joins the two regions. If this order is not followed, then the RSPLINE
will have folds in it that may yield some unexpected interpolation results.

8.

The independent degrees-of-freedom that are the rotation components most nearly
parallel to the line joining the regions should not normally be constrained.

9.

The default RSPLINE implementation has larger-than-expected in-plane rotation at the


two RSPLINE end nodes and where RSPLINE have sharp angles. Applying
PARAM,RSPLICOR reduces such rotation and yields better results.

10. Rigid elements are ignored in heat transfer analysis.

1988 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

RSSCON
Bulk Data Entry
RSSCON Shell-to-Solid Element Connector
Description
Defines multi-point constraints to model clamped connections of shell-to-solid elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RSSC ON

RBID

TYPE

ES1

EA1

EB1

ES2

EA2

EB2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RSSC ON

110

GRID

11

12

13

14

15

16

Field

Contents

RBID

Unique element identification number.

(10)

No default (Integer > 0)


TYPE

Type of connectivity.
ELEM - connection is described with element identification numbers.
GRID - connection is described with grid point.
Default = ELEM (GRID or ELEM)

ES1

Shell element identification number if TYPE = ELEM.


Shell grid point identification number if TYPE = GRID.
No default (Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 1989


Proprietary Information of Altair Engineering

Field

Contents

EA1

Solid element identification number if TYPE = ELEM.


Solid grid point identification number if TYPE = GRID.
No default (Integer > 0)

EB1

Solid grid-point identification number for TYPE = GRID only.


Default = blank (Integer > 0 or blank)

ES2

Shell grid-point identification number for TYPE = GRID only.


Default = blank (Integer > 0 or blank)

EA2

Solid grid-point identification number for TYPE = GRID only.


Default = blank (Integer > 0 or blank)

EB2

Solid grid-point identification number for TYPE = GRID only.


Default = blank (Integer > 0 or blank)

Comments
1.

RSSCON generates a multipoint constraint that models a clamped connection between a


shell and a solid element. The shell degrees-of- freedom are considered dependent. The
translational degrees-of- freedom of the shell edge are connected to the translational
degrees-of- freedom of the upper and lower solid edge. The rotational degrees-offreedom of the shell are connected to the translational degrees-of-freedom of the lower
and upper edges of the solid element face. Poissons ratio effects are considered in the
translational degrees-of-freedom.

2.

The shell grid point must lie on the line connecting the two solid grid points. It can have
an offset from this line, which can not be more than 5% of the distance between the two
solid grid points. The shell grid points that are out of the tolerance will not be
constrained, and a fatal message will be issued. This tolerance is adjustable. Refer to
PARAM,TOLRSC and PARAM,SEPIXOVR.

3.

When using the TYPE = ELEM option:


The elements may be first or second order.
When a straight shell element edge and a solid element are connected, the geometry
of the shell edge is not changed to fit the solid face. When a curved shell element
edge and a solid element are connected, the two solid edges and solid face are not
changed to match the shell edge.

1990 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

It is not recommended to connect more than one shell element to the same solid using
the ELEM option. If attempted, conflicts in the multipoint constraint relations may lead
to UFM 6692.
4.

When using TYPE = GRID option:


The GRID option does not verify that the grids used are valid shell and/or solid grids.
The GRID option is not recommended for 2nd order elements.

5.

It is recommended that the height of the solid elements face is approximately equal to
the shell elements thickness of the shell. The shell edge should then be placed in the
middle of the solid face.

6.

The shell edge may coincide with the upper or lower edge of the solid face.

7.

The RSSCON entry, unlike MPCs, is part of the model and does not need to be selected in
a subcase definition.

8.

RSSCON is ignored in heat-transfer problems.

Altair Engineering

OptiStruct 13.0 Reference Guide 1991


Proprietary Information of Altair Engineering

RWALADD
Bulk Data Entry
RWALADD Rigid Wall Combination for Geometric Nonlinear Analysis
Description
Defines a rigid wall set as a union of rigid walls defined via RWALL entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

RWALADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

etc.

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

RWALADD

101

Field

Contents

SID

Set identification number.

(8)

(9)

(10)

(Integer > 0)
Sj

Set identification numbers of rigid wall sets defined via RWALL entries.
(Integer > 0)

Comments
1.

Multipoint constraint sets must be selected with the Subcase Information command
RWALL=SID.

2.

The Sj must be unique and may not be the identification number of a rigid wall set defined
by another RWALADD entry.

1992 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

RWALADD entries take precedence over RWALL entries. If both have the same SID, only
the RWALADD entry will be used.

4.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1993


Proprietary Information of Altair Engineering

RWALL
Bulk Data Entry
RWALL Rigid Wall for Geometric Nonlinear Analysis
Description
Defines a rigid wall for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

RWALL

SID

RWTYPE

SLID

GISD1

GSID2

FRIC

DIST

G0/X0

Y0

Z0

IFILT

FFAC

X1

Y1

Z1

X2

Y2

Z2

DIA

MASS

VX

VY

VZ

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

RWALL

PLANE

SLIDE

23

21

11

24

12

340

13

(7)

(8)

(9)

(10)

32

Field

Contents

SID

Load set identification number.


No default (Integer > 0)

1994 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

RWTYPE

Rigid wall type.


PLANE Infinite plane.
CYL Infinite cylinder of diameter DIA.
SPHER Sphere of diameter DIA.
PARAL - Parallelogram.
Default = PLANE (PLANE, CYL, SPHERE, or PARAL)

SLID

Flag for sliding.


SLIDE Sliding.
TIED Tied.
SLFRIC Sliding with friction.
Default = SLIDE (SLIDE, TIED, or SLFRIC)

GSID1

Grid set ID defining slave grids to be added to the rigid wall.


(Integer > 0)

GSID2

Grid set ID defining slave grids to be deleted from the rigid wall.
(Integer > 0)

FRIC

Friction coefficient (ignored if SLID = TIED, SLIDE).


Default = 0.0 (Real > 0)

DIST

Distance for slave search (See comment 2).


(Real > 0)

G0

Grid identifier defining M, definition ignores Y0, Z0. Moving rigid wall.
(Integer > 0)

X0, Y0, Z0

Coordinates of a point M defining rigid wall location if G0 not defined.


Rigid wall does not move.
(Real)

IFILT

Friction filtering flag (See comment 4).

Altair Engineering

OptiStruct 13.0 Reference Guide 1995


Proprietary Information of Altair Engineering

Field

Contents
Default = 0 (Integer = 0, , 3)
1 Direct user input of filtering coefficient.
2 Filtering coefficient corresponds to a 3dB filtering level.
3 - Filtering coefficient corresponds to a 3dB filtering level for user
defined frequency (frequency defined in terms of time step number).

FFAC

Friction filtering factor.


Default = 0.0 (Real)

X1, Y1, Z1

Coordinates of a point defining M1 for RWTYPE = PLANE, CYL, PARAL.


(Real)

X2, Y2, Z2

Coordinates of a point defining M2 for RWTYPE = PARAL.


(Real)

DIA

Diameter for RWTYPE = CYL, SPHER.


(Real > 0)

MASS

Mass of moving rigid wall if G0 is defined.


(Real > 0)

VX, VY, VZ

Components of initial velocity if G0 is defined.


(Real)

Comments
1.

RWALL must be selected in the subcase with RWALL = SID or by RWALADD. It can only
be selected in geometric nonlinear analysis subcases which are defined by an ANALYSIS =
NLGEOM, IMPDYN or EXPDYN subcase entry.

2.

Initially the slave nodes can be defined at a distance lower than DIST.

3.

Nodal thickness of rigid wall slave nodes is not taken into account.

4.

IFILT defines the method for computing the friction filtering coefficient. Friction filtering
slave node in contact are filtered using a simple rule:
F T = * F'T + (1 - ) * F'T-1

1996 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

where,
F T - Tangential force
F'T - Tangential force at time t
F'T-1 - Tangential force at time t-1
- filtering coefficient
IFILT = 1 = FFAC
IFILT = 2 = 2 dt * freq, where dt = time step, and freq = FFAC
IFILT = 3 = 2
5.

6.

/ N, with 1/freq = T = N * dt, and N = FFAC

Surface input type


Type

Description

PLANE

MM1 defines the normal direction.

CYL

MM1 defines the axis of the cylinder.

SPHER

M is the center of the sphere.

PARAL

MM1 and MM2 define the parallelogram with the normal


as cross product MM1 x MM2.

This card is represented as a rigid wall in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 1997


Proprietary Information of Altair Engineering

SECT
Bulk Data Entry
SECT Section Definition for Section Force Output in Geometric Nonlinear Analysis
Description
Defines a section for force output in geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SEC T

SC ID

G0

G1

G2

GRSET

ELSET

IFRAME

C ID

(10)

DT

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

SEC T

234

665

723

Field

Contents

SCID

Section identification number.

(8)

(9)

(10)

No default (Integer > 0)


G0, G1, G2

Grid points defining the local axes of the section. G0 and G1 define
the local x-axis while G0, G1, and G3 define the local xy-plane.
No default (Integer > 0)

GRSET

Grid set ID.


No default (Integer > 0)

ELSET

Element set ID. Only sets of SOLID, SHELL, ROD, BAR, and BEAM
elements can be used.
(Integer > 0)

1998 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

IFRAME

Flag for computing the center of the output coordinate system.


The local system is defined by G0, G1, and G2.
Default = 0 (Integer = 0, 1, 2, 3, 10, 11, 12, 13)
0 Origin of the local system defined by G0, G1, and G2
1 Geometrical center of the section grid in the local system
defined by G0, G1, and G2
2 Center of gravity of the section in the local system defined by
G0, G1, and G2
3 Origin of the basic system in the local system defined by G0,
G1, and G2
10 Origin of the basic system
11 Geometrical center of the section in the basic system
12 Center of gravity of the section in the basic system
13 Origin of the basic system

CID

Moving coordinate system identifier for automatic definition of a


section. Only CORD1R and CORD3R can be selected (See comment
4).
Default = 0 (Integer > 0)

DT

Time step for saving the data.


Default = DTTH defined on XSOM (Real > 0)

Comments
1.

SECT output must be selected for time history output with XHIST. It is only available for
geometric nonlinear analysis subcases which are defined by an ANALYSIS = NLGEOM,
IMPDYN or EXPDYN subcase entry.

2.

Moments are computed with respect to the section center defined by the parameter
IFRAME and expressed in the local section frame.

3.

Normal force is the component normal to the XY plane of the section. The tangential
force is the component in the plane of the section.

4.

For CID > 0:


G0, G1, G2 blank the local system of the section is built from the grid points defining
the CORD1R or CORD3R.
The element set is created automatically from the elements intersected by the xyplane of CID.

Altair Engineering

OptiStruct 13.0 Reference Guide 1999


Proprietary Information of Altair Engineering

The grid set is created automatically from the grid points of the intersected elements
on the positive z-axis defined by the xy-plane plane of the frame.
5.

This card is represented as an interface in HyperMesh.

2000 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SENSOR
Bulk Data Entry
SENSOR Sensor Definition
Description
Defines a sensor for geometric nonlinear analysis. Sensors may be used to activate loads
(see NLOAD1).
Format
(1)

(2)

(3)

(4)

(5)

SENSOR

SID

STYPE

DELAY

NAC C

(6)

(7)

(8)

(9)

(10)

Continuation lines if STYPE = ACCEL (number of continuation lines = NACC)


AID1

DIR1

AMIN1

TMIN1

AID2

DIR2

AMIN2

TMIN2

Continuation line if STYPE = DIST


G1

G2

DMIN

DMAX

Continuation line if STYPE = SENS, AND, OR


SID1

SID2

Continuation line if STYPE = NOT


SID1

Continuation line if STYPE = INTER


C ID

Altair Engineering

OptiStruct 13.0 Reference Guide 2001


Proprietary Information of Altair Engineering

Continuation line if STYPE = RWAL


RWID

Example

(1)

(2)

(3)

(4)

SENSOR

100

AC C EL

500.0

(5)

(6)

(7)

(8)

(9)

(10)

0.03

Field

Contents

SID

Unique sensor identification number.


No default (Integer > 0)

STYPE

Sensor type. May be one of:


TIME Start Time
ACCE Accelerometer
DIST Nodal distance
SENS Activation with sensor SID1, deactivation with sensor SID2
INTER Interface activation and deactivation
RWAL Rigid wall activation and deactivation
AND ON as long as sensors SID1 and SID2 are ON
NOT ON as long as sensor SID1 is OFF
OR ON as long as sensors SID1 and SID2 are ON
No default (ACCEL, AND, DIST, INTER, NOT, OR, RWAL, SENS, or
TIME)

DELAY

Time delay.
(Real > 0)

NACC

Number of accelerometers ACCEL.


(0 < Integer < 6)

AID#

Accelerometer identifier, references the ID of an ACCLR bulk data


entry.
(Integer > 0)

2002 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

DIR#

Direction of accelerometer #. May be one of:


X X direction
Y Y direction
Z Z direction

XY XY plane

YZ YZ plane

ZX ZX plane

XYZ total acceleration


No default (X, Y, Z, XY, XZ, YZ, or XYZ)
AMIN#

Minimum absolute value for acceleration for accelerometer #.


(Real > 0)

TMIN#

Minimum duration of AMIN for accelerometer #.


(Real > 0)

G1

Grid ID 1.
(Integer > 0)

G2

Grid ID 2.
(Integer > 0)

DMIN

Distance minimum.
(Real > 0)

DMAX

Distance maximum.
(Real > 0)

SID1

Activation sensor identifier, references the ID of another SENSOR


bulk data entry.
(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 2003


Proprietary Information of Altair Engineering

Field

Contents

SID2

Deactivation sensor identifier, references the ID of another SENSOR


bulk data entry.
(Integer > 0)

CID

Contact identifier, references the ID of a CONTACT bulk data entry.


(Integer > 0)

RWID

Rigid Wall identifier, references the ID of a RWALL bulk data entry.


(Integer > 0)

Comments
1.

A sensor can only be activated once.

2.

For STYPE=TIME, the sensor is activated after the time delay (DELAY).

3.

For STYPE=ACCE, the sensor is activated if one of the accelerometers gives an


acceleration greater than AMIN during a time greater than TMIN.
The time of activation of the sensor is the time at which the above criteria is first met
plus the time delay (DELAY).

4.

For STYPE=DIST, the sensor is activated once the distance between G1 and G2 moves
outside the allowable range (between DMIN and DMAX).
The time of activation of the sensor is the time at which the above criteria is first met,
plus the time delay (DELAY).

5.

For STYPE=SENS, the sensor is activated once the referenced sensor SID1 is activated.
The minimum activation duration is given by the time delay (DELAY). After this minimum
activation duration, the sensor is deactivated if referenced sensor SID2 is activated. If
there is no SID2 referenced, then the sensor is deactivated after the time delay.

2004 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

6.

For STYPE=AND, the sensor is activated once both the referenced sensors (SID1 and
SID2) are activated.

7.

For STYPE=OR, the sensor is activated once either of the referenced sensors (SID1 or
SID2) are activated.

8.

For STYPE=NOT, the sensor is active whenever the referenced sensor SID1 is not active.

Altair Engineering

OptiStruct 13.0 Reference Guide 2005


Proprietary Information of Altair Engineering

9.

For STYPE=INTER, the sensor is activated once the referenced contact (CID) is impacted.
The sensor is deactivated if there is no impact during a time equal to the time delay
(DELAY).

10. For STYPE=RWAL, the sensor is activated once the referenced rigid wall (RWID) is
impacted. The sensor is deactivated if there is no impact during a time equal to the time
delay (DELAY).

2006 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SET
Bulk Data Entry
SET Set Definition
Description
Defines a set of grids, elements, design variables, MBD entities, mode numbers, frequencies or
times for reference by other input definitions.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET

SID

TYPE

SUBTYPE/
OPERATOR

ID1/
MODE1/
REAL1/
NAME1/
SID1/
X1/G1/
ALL

ID2/
MODE2/
REAL2/
NAME2/
SID2/
Y1

ID3/
MODE3/
REAL3/
NAME3/
SID3/
Z1

ID4/
MODE4/
REAL4/
NAME4/
SID4/
X2/G2

ID5/
MODE5/
REAL5/
NAME5/
SID5/
Y2

ID6/
MODE6/
REAL6/
NAME6/
SID6/
Z2

ID7/
MODE7/
REAL7/
NAME7/
SID7

ID8/
MODE8/
REAL8/
NAME8/
SID8

ID9/
MODE9/
REAL9/
NAME9/
SID9

(10)

Alternate Format for ID Ranges


(1)

(2)

(3)

(4)

SET

SID

TYPE

SUBTYPE

ID1

THRU

ID2

ID7

ENDTHRU

(5)

(6)

(7)

(8)

(9)

EXC EPT

ID3

ID4

ID5

ID6

(10)

Altair Engineering

OptiStruct 13.0 Reference Guide 2007


Proprietary Information of Altair Engineering

Example 1
The following set contains the grids 1, 17, 22, 23, 29, 33, 35, 48, 88, 93 and 102. It is
defined using a simple ID list (assuming that these GRID cards are present in the Bulk
Data).
(1)

(2)

(3)

(4)

SET

56

GRID

LIST

88

93

17

33

102

22

(5)

(6)

(7)

(8)

(9)

23

29

35

48

(10)

Example 2
The following set contains the elements 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 33,
34, 34, 35, 36, 37, 38, 41, 42, 43, 44, 45, 94, 95, 96. 97, 98, 99, 106, 107, 108, 109, 110,
111, 120, 121 and 125. It is defined using a combination of ID ranges and lists.
(1)

(2)

(3)

(4)

(5)

(6)

(7)

SET

56

ELEM

LIST

11

THRU

22

33

THRU

45

EXC EPT

39

40

94

THRU

111

EXC EPT

100

101

104

105

ENDTHR
U

120

121

125

(8)

(9)

102

103

(10)

Example 3
The following set includes any element included in sets 29, 30 or 31. It is defined as
Boolean set.

2008 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

SET

50

ELEM

OR

29

30

31

(5)

(6)

(7)

(8)

(9)

(10)

Example 4
The following set defines GRID/Component list; intended for use by PFMODE.
(1)

(2)

(3)

SET

11

GRIDC

12

T1

(4)

(5)

(6)

(7)

15

R2

128

T3

(8)

(9)

(10)

(8)

(9)

(10)

(9)

(10)

Example 5
The following set defines list of strings.
(1)

(2)

(3)

SET

11

LABEL

LABEL1

LABEL2

(4)

(5)

(6)

(7)

TOP

UPPER

LOWER

LEFT

Example 6
The following set defines list of all elements with specific properties.
(1)

(2)

(3)

(4)

(5)

(6)

SET

11

ELEM

PROP

EXC EPT

PHSELL

12

15

thru

128

(7)

(8)

555

Example 7

Altair Engineering

OptiStruct 13.0 Reference Guide 2009


Proprietary Information of Altair Engineering

The following set outputs all of the grids on PLOTEL.


(1)

(2)

(3)

(4)

SET

ID

GRID

ELTYPE

(5)

(6)

(7)

(8)

(9)

(10)

PLOTEL

Field

Contents

SID

Unique set identification number. See comment 1.


No default (Integer > 0)

TYPE

Identifies what type of entities the set is comprised of. See comment 2
for description of the types.
No default (GRID, ELEM, RIGID, GRIDC, DESVAR, MODE, FREQ, TIME,
LABEL or PLY)

SUBTYPE

Indicates how the set is defined. See comment 2 for description of


subtypes.
Default = LIST (LIST, BBOX, PROP, MAT or ELTYPE)

OPERATOR

Operators supported in defining Boolean sets (see comments 4, 5, and


6.)
No default (OR, AND, NOT, MINUS)

ID#

ID list. Only valid for certain combinations of TYPE and SUBTYPE. The
entity to which the ID corresponds depends on the TYPE and SUBTYPE
of the set (see comment 2).
ID ranges may be used in combination with ID lists. The keywords
EXCEPT and THRU are used to define ID ranges. The keyword ENDTHRU
identifies the end of an ID range and is required if an ID list is to follow
where the first value is within the previous range.
ID lists following EXCEPT must be in ascending order and must exist
within the previous range.
No default (Integer > 0)

MODE#

Mode number list. Only valid when TYPE is MODE (see comment 2).
Mode number ranges may be used in combination with Mode number
lists. The same rules apply as for ID ranges.
No default (Integer > 0)

2010 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

REAL#

Real value list. Only valid when TYPE is FREQ or TIME (see comment
2).
No default (Real)

NAME#

Keyword list. Only valid for certain combinations of TYPE and SUBTYPE.
The keyword EXCEPT is allowed only as the first entry in a keyword list.
Default = Undefined (see comment 2)

SID#

Identification number of another SET definition. Used in defining Boolean


sets. Only valid when OPERATOR is defined in SUBTYPE/OPERATOR field
(see comments 4, 5, 6, and 7).
No default (Integer > 0 or <PartName.number>)

X1, Y1, Z1
X2, Y2, Z2

X, Y & Z coordinates of two opposing corners of a cuboid. Only valid


when SUBTYPE is BBOX (see comment 2).
No default (Real)

G1, G2

Grid IDs (G1, G2) can be used instead of (X1, Y1, Z1), (X2, Y2, Z2)
data (see field descriptions above). G1, G2 should be defined in the
basic coordinate system (CP field on the GRID entries should be blank).

ALL

Keyword used for ID lists to indicate that all IDs of the appropriate
entity type are to be included in the set.
Only valid in first field of ID list.
May be followed by keyword EXCEPT (see below).

THRU

Keyword used for ID ranges to indicate that all IDs between the
preceding ID and the following ID are to be included in the set.
Definition of range may contain list of exceptions in the following form:
N1 THRU N2 EXCEPT N3 N4 ... ENDTHRU
where N1 < N3 < N4... < N2; N1 < N2

EXCEPT

Keyword used for ID ranges and keyword lists to indicate that the
following IDs or keywords are to be excluded from the set.
Only valid in first field for keyword lists.
When ALL is given as the first entry for an ID list, EXCEPT may be given
as the second entry, in which case all subsequent IDs are excluded from
the set of ALL entities of the defined TYPE.

Altair Engineering

OptiStruct 13.0 Reference Guide 2011


Proprietary Information of Altair Engineering

Field

Contents

ENDTHRU

Optional keyword used after EXCEPT to indicate the end of an excluded


ID list definition.

Comments
1.

SID must be unique with respect to all other SET definitions (regardless of type). It must
also be unique with respect to any SURF entries and any legacy SET/PSET I/O Options
definitions.

2.

The following table describes subtype combinations and the set TYPEs for which they are
valid.
TYPE

SUBTYPE

Description

GRID

LIST
or
undefined

This is a set of grids - structural grids (GRID) or scalar


points (SPOINT) - defined either as a simple list of grid
IDs, or as some combination of ranges of grid IDs and
lists of grid IDs.

BBOX

This is a set of grids defined by a bounding box. The


fields X1, Y1, and Z1 provide the coordinates of one
corner and X2, Y2, and Z2 the coordinates of an
opposing corner of a cuboid. All grids contained within
this cuboid are included in the set.
The bounding box can also be defined using the G1 and
G2 fields instead of (X1, Y1, and Z1) and (X2, Y2, and
Z2), respectively.

ELEM

LIST
or
undefined

This is a set of elements defined either as a simple list of


element IDs, or as some combination of ranges of
element IDs and lists of element IDs.

BBOX

This is a set of elements defined by a bounding box. The


fields X1, Y1, and Z1 provide the coordinates of one
corner and X2, Y2, and Z2 the coordinates of an
opposing corner of a cuboid. All elements whose
centroids are contained within this cuboid are included in
the set.
The bounding box can also be defined using the G1 and
G2 fields instead of (X1, Y1, and Z1) and (X2, Y2, and
Z2), respectively.

PROP

This is a set of elements defined in one of the following


ways:
1.

Through a list of property IDs, or some combination

2012 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TYPE

SUBTYPE

Description
of ranges of property IDs and lists of property IDs.
If multiple properties have the same ID (as PBAR and
PSHELL may), they are all considered. All elements
referencing the selected properties are included in
the set.
2.

Through a list of property types. All elements


referencing properties of the listed type (PBAR,
PCOMP, PSHELL, and so on) are included in the set.

3.

Through a list of excluded property types. All


elements except those referencing properties of the
listed type, following the keyword EXCEPT, are
included in the set.

4.

List of property types or list of excluded property


types may be followed by some combination of
ranges of property IDs and lists of property IDs. All
elements referencing properties satisfying both
requirements (type and ID) are included in (or
accepted from) the set.

MAT

This is a set of elements defined through a list of


material IDs, or some combination of ranges of material
IDs and lists of material IDs. All elements referencing
properties, that in turn reference the selected materials,
are included in the set.

ELTYPE

This is a set of elements defined in one of the following


ways:
1.

Through a list of element types. All elements of the


listed type (CQUAD4, CHEXA, CBEAM, and so on) are
included in the set.

2.

Through a list of excluded element types. All


elements except those of the listed type, following
the keyword EXCEPT, are included in the set.

In addition to all valid element types, the following


element type groupings may be used:

Altair Engineering

SOLID

for CTETRA, CPYRA, CPENTA and CHEXA


elements referencing structural property
definitions

FLAT

for CQUAD4, CQUAD8, CTRIA3 and CTRIA6


elements.

OptiStruct 13.0 Reference Guide 2013


Proprietary Information of Altair Engineering

TYPE

SUBTYPE

Description
SHELL

for FLAT elements referencing properties


with non-zero MID2.

MEMBRANE for FLAT elements referencing properties


with zero MID2.
BEAM

for CBAR and CBEAM elements.

ROD

for CONROD and CROD elements.

FLUID

for CTETRA, CPYRA, CPENTA and CHEXA


elements referencing fluid property
definitions.

For rigid elements (RROD, RBAR, RBE1, RBE2 and RBE3).


See RIGID below.
RIGID

LIST
or
undefined

This is a set of Rigid elements defined either as a simple


list of Rigid element IDs, or as a combination of ranges of
Rigid element IDs and lists of Rigid element IDs.

GRIDC

LIST
or
undefined

This is a set of GRID/Component pairs.

DESVAR

LIST
or
undefined

This is a set of design variables defined either as a


simple list of design variable IDs, or as some combination
of ranges of design variable IDs and lists of design
variable IDs.

MODE

LIST
or
undefined

This is a set of mode numbers defined as a simple list of


mode numbers, or as some combination of ranges of
mode numbers and lists of mode numbers.

FREQ

LIST
or
undefined

This is a set of real values representing frequencies


defined simply as a list of real values.

TIME

LIST
or
undefined

This is a set of real values representing times defined


simply as a list of real values.

LABEL

LIST
or
undefined

List of arbitrary labels. Each label must start with a


letter and contain only letters or digits.

2014 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TYPE

SUBTYPE

Description

PLY

LIST
or
undefined

This is a set of ply IDs defined in the PLY or PCOMPG


data entries.

3.

SET definitions using IDs may refer to non-existing entities. This is allowed, but the
actual SET will contain only grids or elements which are actually present in the structure.

4.

The Boolean operators OR, AND, NOT and MINUS are recognized for SET combinations.
These operators are described here:
Operator Description
OR

An entity is included in the SET if it is included in at least one of the


constituent sets. Is the entity in set1 or set2 or set3 ?

AND

An entity is included in the SET if it is included in all of the listed sets. Is


the entity in set1 and set2 and set3 ?

NOT

An entity is included in the SET if it is not included in the listed set. Is


the entity in set1?; if not then it is included in this set.
Only one set may be listed for the NOT operator.

MINUS

An entity is included in the SET if it is included in the first set, but not in
the second set. Only two sets may be listed for when this operator is
used.

5.

Boolean SET definitions can only be used when all listed sets are of the same TYPE.

6.

Boolean SET definitions can reference other Boolean sets, but circular references must be
avoided. Boolean SET can be defined only for GRID, ELEM, or RIGID set types.

7.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on SET entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN bulk data entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.
The SET bulk data entry can be used in the global part to reference SETs defined within
different parts. These SET entries in the global part can contain fully qualified references
to part-specific SET data only if logical operators (OPERATOR field) are used. For
example:
The following SET entry exists in part A:
BEGIN, FEMODEL, A
SET, 29, ELEM, LIST

Altair Engineering

OptiStruct 13.0 Reference Guide 2015


Proprietary Information of Altair Engineering

15 THRU 30

END, FEMODEL, A
Referencing SET, 29 in the global part G:
BEGIN, FEMODEL, G
SET, 78, ELEM, OR
A.29

END, FEMODEL, G
8.

This card is represented as a set in HyperMesh.

2016 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SET1
Bulk Data Entry
SET1 Set Definition
Description
Defines a list of structural grid points or element identification numbers.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET1

SID

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

etc.

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET1

31

62

93

124

16

17

18

(10)

19

Example 2

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET1

29

32

THRU

50

61

THRU

70

17

57

Field

Contents

SID

Unique identification number.

(10)

(Integer > 0)

Altair Engineering

OptiStruct 13.0 Reference Guide 2017


Proprietary Information of Altair Engineering

Field

Contents

IDi

List of structural grid point or element identification numbers.


(Integer > 0 or "THRU, ENDTHRU, and EXCEPT"; for the "THRU" option,
ID1 < ID2)

Comments
1.

When using "THRU," missing ID's are ignored.

2.

All set IDs must be unique for all bulk data SET, SET1, SET3, and solution control SET
data.

3.

The use of keywords THRU, ENDTHRU, and EXCEPT are allowed.

4.

This card is represented as a set in HyperMesh.

2018 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SET3
Bulk Data Entry
SET3 Set Definition
Description
Defines a set of grids or elements.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET3

SID

TYPE

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

etc.

(10)

Example 1

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SET3

PROP

11

12

13

15

18

21

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

SET3

SID

TYPE

ID1

"THRU"

ID2

SET3

33

GRID

20

THRU

60

Field

Contents

SID

Unique identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
TYPE

Set type (Character). Valid options include "GRID," "ELEM," and "PROP."

Altair Engineering

OptiStruct 13.0 Reference Guide 2019


Proprietary Information of Altair Engineering

Field

Contents

IDi

Identifiers of grid points, elements, or properties.


(Integer > 0)

Comments
1.

If the set type is PROP, then a list of elements associated with the property ID's listed is
created.

2.

All set IDs must be unique for all bulk data SET, SET1, SET3, and solution control SET
data.

3.

The use of keywords THRU, ENDTHRU, and EXCEPT are allowed.

4.

This card is represented as a set in HyperMesh.

2020 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SLOAD
Bulk Data Entry
SLOAD Static Scalar Load
Description
Defines concentrated static loads on scalar, grid or fluid points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

SLOAD

SID

S1

F1

S2

F2

S3

F3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

SLOAD

21

4.5

29.0

Field

Contents

SID

Load set identification number.

(7)

(8)

(9)

(10)

No default (Integer > 0)


S#

Identification number of a scalar, grid or fluid point.


No default (Integer > 0)

F#

Load magnitude.
No default (Real)

Comments
1.

SLOAD may be referenced as the EXCITEID on an ACSRCE bulk data entry.

2.

Up to three loads may be defined on a single entry.

Altair Engineering

OptiStruct 13.0 Reference Guide 2021


Proprietary Information of Altair Engineering

SOLVTYP
Bulk Data Entry
SOLVTYP Solver Selection for Static Analysis and Geometric Nonlinear Implicit Analysis
Description
This bulk data entry can be used to define the solver type to be used for linear and nonlinear
static analysis and geometric nonlinear implicit analysis.
Format
(1)

(2)

(3)

(4)

SOLVTYP

SID

SOLVER

(5)

(6)

(7)

(8)

(9)

(10)

Continuation line for SOLVER = PCG, MIXED and AUTO


PC ON

MAXIT

ITOL

TOL

Continuation line for SOLVER = MUMPS


ORDM

Example

(1)

(2)

(3)

SOLVTYP

PC G

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FAI

Alternate Example

(1)

(2)

(3)

SOLVTYP

MUMPS

2022 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PORD

Field

Contents

SID

Unique set identification number.


No default (Integer > 0)

SOLVER

Indicates the solver to be used. See comments 2, 3 and 4.


BCS Boeing Solver (direct solver).
MUMPS MUMPS Solver (direct solver).
PCG - Preconditioned Conjugate Gradient (iterative solver).
MIXED Mixed solver using both BCS and PCG.
AUTO Select automatic between BCS and PCG.
Default = BCS - for linear static analysis and geometric nonlinear implicit
dynamic analysis (ANALYSIS = IMPDYN);
Default = MIXED - for geometric nonlinear implicit static analysis
(ANALYSIS = NLGEOM).

PCON

Indicates the type of pre-conditioner to be used.


NO - No Pre-conditioner
DJ - Diagonal Jacobi
ICH - Incomplete Cholesky
SICH - Stabilized Incomplete Cholesky
FAI - Factored Approximate Inverse
Default = FAI (Character)

MAXIT

Maximum number of iterations


Default = Number of degrees-of-freedom of the system (Integer > 0 or
blank)

ITOL

Convergence criteria for preconditioned iterative solver.


RROM - Relative residual of original matrices ||r|| < TOL * ||b||
RRPM1 - Relative residual of preconditioned matrices ||r|| < TOL * ||

Altair Engineering

OptiStruct 13.0 Reference Guide 2023


Proprietary Information of Altair Engineering

Field

Contents
b||
RRPM2 - Relative residual of preconditioned matrices ||r|| < TOL * ||
A|| * ||x||
If the solver solves Ax = b, the residual is r = Ax - b.
Default = RRPM2 (Character)

TOL

Convergence tolerance.
Default = 1.0e-5 for ITOL = RROM, RRPM1 or
single precision machine precision (3.0e-8) for ITOL = RRPM2 (Real > 0
or blank)

ORDM

Ordering method for the MUMPS solver (see comments 8 and 9).
AMD Approximate minimum degree method (AMD)
PORD PORD package
METIS METIS package
AUTO Automatically select between PORD and METIS.
Default = METIS (Character)

Comments
1.

SOLVTYP bulk data must be referenced by a SOLVTYP subcase statement. It only applies
to linear static subcases, geometric nonlinear implicit static analysis (ANALYSIS=NLGEOM)
and geometric nonlinear implicit dynamic analysis (ANALYSIS=IMPDYN).

2.

In optimization of linear static subcases, if iterative solver is selected, and if the


responses DRESP1, RTYPE = DISP, LAMA, STRESS, STRAIN, CSTRESS, CSTRAIN,
CFAILURE, or FORCE are present the solver is automatically reverted to the direct solver.

3.

MUMPS is the default non-symmetric solver for nonlinear contact analysis when friction is
present; it is also available as an optional symmetric solver for static runs. MUMPS is SMP
parallelized. Generally, MUMPS performance is similar to or better than the performance of
BCS, especially for 2D models.
MUMPS stands for Multifrontal Massively Parallel sparse direct Solver.
For more details, see http://graal.ens-lyon.fr/MUMPS/index.php?page=home

4.

Overview of default settings and options for the SOLVER field:

2024 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SOLVER
=BCS

SOLVER
=MUMPS

SOLVER
=PCG

SOLVER
=MIXED

SOLVER
=AUTO

Linear static
analysis

Default

Optional

Optional

N/A

N/A

Nonlinear static
analysis

Default

Optional

N/A

N/A

N/A

Nonlinear contact
analysis (when
friction is
present)

Optional

Default

N/A

N/A

N/A

Geometric
nonlinear implicit
static analysis
(NLGEOM)

Optional

N/A

Optional

Default

Optional

Geometric
nonlinear implicit
dynamic analysis
(IMPDYN)

Default

N/A

Optional

Optional

Optional

Subcase type

5.

The iterative solver is a preconditioned conjugate gradient solver. A Factored


Approximate Inverse Preconditioner is the default method. This solver is also SMP
parallelized.

6.

The performance of the iterative solver depends on the conditioning of the stiffness
matrix. For compact solid models, the iterative solver may perform considerably better
than the direct solver in terms of memory usage and elapsed times for a single linear
static subcase. In the case of multiple linear static subcases, the iterative solver may
perform worse than the direct solver. The breakeven point is at about 4-6 subcases.
The performance depends on model, hardware, operating system, and potentially the
system load. The performance may be below expectations on Itanium-based computers.

7.

When the automatic solver option (SOLVER = AUTO) has been chosen, PCG is used first,
the solver will be changed automatically to direct solver (BCS) if PCG performance is
estimated slower than direct solver. In this case, direct solver will be used for the
remainder of the run.

8.

ORDM = PORD provides better performance for a shell-type model.

9.

For further information about the MUMPS solver ordering method (ORDM) options, refer to
the MUMPS 4.10 manual.

10. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2025


Proprietary Information of Altair Engineering

SPC
Bulk Data Entry
SPC Single-Point Constraint
Description
Defines sets of single-point constraints, enforced displacements for static analysis, and
thermal boundary conditions for heat transfer analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

SPC

SID

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

SPC

32

436

0.0

(6)

(7)

Field

Contents

SID

Identification number of single-point constraint set.

(8)

(9)

(10)

(Integer > 0)
G

Grid or scalar point identification number.


(Integer > 0 or <PartName.number>)

Component numbers.
(Integer zero or blank for scalar points, or up to six unique digits (0 < digit <
6) may be placed in the field with no embedded blanks for grid points. The
components refer to the coordinate system referenced by the grid points.)

Value of enforced displacement for all coordinates designated by G and C.


(Real)

Comments

2026 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

1.

The degree-of-freedom declared dependent on this entry may not be:


Included in a single point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any RBAR, RBE1, RBE2, or RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced in the same
subcase.

2.

Single-point forces of constraint are recovered during stress data recovery.

3.

Up to twelve single-point constraints may be defined on a single entry.

4.

Continuations are not allowed.

5.

SPC degrees-of-freedom may be redundantly specified as permanent constraints on the


GRID entry.

6.

For static analyses, SPCs can be used to define enforced displacements.

7.

For static and dynamic analyses, when the SPSYNTAX setting on the SYSSETTING I/O
option is set to CHECK (default) or STRICT, it is required for grid/component pairs (G#/
C#) that the component be 0 or blank when the grid reference is a scalar point (SPOINT),
and that the component be > 1 when the grid reference is a structural grid point (GRID).
When SPSYNTAX is set to MIXED, it is allowed for grid/component pairs (G#/C#) that the
grid reference be either a scalar point (SPOINT) or a structural grid point (GRID) when the
component is 0, 1 or blank; interpreting all of these as 0 for scalar points and as 1 for
structural grids. When the component is greater than 1, the grid reference must always
be a structural grid (GRID).

8.

For linear steady-state heat transfer analysis, an SPC may be used to define a
temperature boundary condition. For thermal boundary conditions, the component should
be 0 or blank when the SPSYNTAX setting on the SYSSETTING I/O option is set to
CHECK(default) or STRICT. When SPSYNTAX is set to MIXED 1 is also accepted as the
component.

9.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on SPC entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

10. This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2027


Proprietary Information of Altair Engineering

SPC1
Bulk Data Entry
SPC1 Single-Point Constraint, Alternate Form
Description
Defines sets of single-point constraints and thermal boundary conditions.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SPC 1

SID

G1

G2

G3

G4

G5

G6

G7

G8

G9

-etc.-

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

(5)

(6)

SPC 1

SID

G1

"thru"

G2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SPC 1

10

THRU

33

71

87

thru

SPC 1

(10)

100

Field

Contents

SID

Identification number of single-point constraint set.


(Integer > 0)

2028 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Component number.
(Integer zero or blank for scalar points, or up to six unique digits (0 < digit <
6) may be placed in the field with no embedded blanks for grid points. The
components refer to the coordinate system referenced by the grid points.)

Gi

Grid or scalar point identification numbers.


(Integer > 0)

Comments
1.

The degree-of-freedom declared dependent on this entry may not be:


Included in another single-point constraint (SPC or SPC1).
Declared a dependent degree-of-freedom on any RBAR, RBE1, RBE2, or RROD entry.
Declared a dependent degree-of-freedom on an MPC set referenced in the same
subcase.

2.

Note that enforced displacements are not available via this entry.

3.

Any number of continuations may appear.

4.

Multiple thru sequences can be used on a single card, and can span across continuation
lines.

5.

SPC degrees-of-freedom may be redundantly specified as permanent constraints on the


GRID entry.

6.

If the "thru" comment is used, G1 and G2 must exist, but the grid points between G1 and
G2 are not required to exist.

7.

For static and dynamic analyses, when the SPSYNTAX setting on the SYSSETTING I/O
option is set to CHECK (default) or MIXED, it is allowed that when grid lists are provided
for a given component, that the grid references be either scalar points (SPOINT) or
structural grid points (GRID) when the component is 0, 1 or blank; interpreting all of these
as 0 for scalar points and as 1 for structural grids. When SPSYNTAX is set to STRICT, it
is required for grid/component pairs (G#/C#) that the component be 0 or blank when the
grid references are to scalar points (SPOINT), and that the component be > 1 when the
grid references are to structural grid points (GRID). When the component is greater than
1, the grid references must always be a structural grid (GRID).

8.

For linear steady-state heat transfer analysis, SPC1 may be used to define temperature
boundary conditions; however, unless paired with an SPCD entry, the enforced
temperature is 0.0. For thermal boundary conditions, the component should be 0 or blank
when the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT. When SPSYNTAX is set to MIXED, 1 is also accepted as the component.

9.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2029


Proprietary Information of Altair Engineering

SPCADD
Bulk Data Entry
SPCADD Single-Point Constraint Set Combination
Description
Defines a single-point constraint set as a union of single-point constraint sets defined via SPC
or SPC1 entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SPC ADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

(10)

-etc-

Example

(1)

(2)

(3)

(4)

(5)

(6)

SPC ADD

101

(7)

Field

Contents

SID

Identification number for new single-point constraint set.

(8)

(9)

(10)

(Integer > 0)
Si

Identification numbers of single-point constraint sets defined via SPC or SPC1


entries.
(Integer > 0 or <PartName.number>) See comment 5.

Comments
1.

The Si field should not reference the identification number of a single-point constraint set
defined by another SPCADD entry.

2.

The Si values must be unique.

2030 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

SPCADD entries take precedence over SPC or SPC1 entries. If both have the same set
ID, only the SPCADD entry is used.

4.

If all Si are non-existent the solver will exit with an error termination.

5.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on SPCADD entries in the model. A fully qualified reference
(PartName.number) is similar to the format of a numeric reference. PartName is the
name of the part that contains the referenced local entry (part names are defined on the
BEGIN Bulk Data Entry in the model). number is the identification number of a
referenced local entry in the part PartName. See Parts and Instances in the Users
Guide for detailed information on the use of fully qualified references.

6.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2031


Proprietary Information of Altair Engineering

SPCD
Bulk Data Entry
SPCD Enforced Motion Value
Description
Defines an enforced displacement value for static analysis, an enforced displacement, velocity
or acceleration for dynamic analysis and a thermal boundary condition for heat transfer (or
transient heat transfer) analysis. It can also be used to define the EXCITEID field (Amplitude
A) of dynamic loads in RLOAD1, RLOAD2, TLOAD1 and TLOAD2 bulk data entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

SPC D

SID

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

SPC D

100

32

436

-2.6

+2.9

Field

Contents

SID

Identification number of a static load set.

(9)

(10)

(Integer > 0)
G

Grid or scalar point identification number.


(Integer > 0 or <PartName.number>) See comment 9.

Component numbers in the global coordinate system.


(6 > Integer > 0; up to six unique such digits may be placed in the field with
no embedded blanks)

Value of enforced motion for all grids and components designated by G and
C.

2032 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Real)

Comments
1.

The degree-of-freedom (G and C) referenced on this entry must also be referenced on an


SPC or SPC1 bulk data entry and selected by the SPC subcase information command in
the same subcase.

2.

For use in linear static and linear steady state heat transfer analyses, the load set
identification number must be selected by the LOAD subcase information command.

3.

Values of D will override the values specified on an SPC bulk data entry if selected for use
in the same subcase.

4.

For use in dynamic analysis, the load set identification number must be referenced by the
EXCITEID field of an RLOAD1, RLOAD2, TLOAD1, or TLOAD2 bulk data entry that has
enforced motion specified in its TYPE field.

5.

The bulk data LOAD combination entry cannot combine an SPCD load.

6.

This method of applying enforced displacements in static analysis is equivalent to that of


using an SPC entry. For static and dynamic analyses, when the SPSYNTAX setting on
the SYSSETTING I/O option is set to CHECK (default) or STRICT, it is required for grid/
component pairs (G#/C#) that the component be 0 or blank when the grid reference is a
scalar point (SPOINT), and that the component be > 1 when the grid reference is a
structural grid point (GRID). When SPSYNTAX is set to MIXED, it is allowed for grid/
component pairs (G#/C#) that the grid reference be either a scalar point (SPOINT) or a
structural grid point (GRID) when the component is 0, 1 or blank; interpreting all of these
as 0 for scalar points and as 1 for structural grids. When the component is greater than
1, the grid reference must always be a structural grid (GRID).

7.

The SPCD units for rotational degrees of freedom is radians.

8.

For use in transient heat transfer analysis, the load set identification number must be
referenced by the EXCITEID field of a TLOAD1 or TLOAD2 bulk data entry that has
enforced temperature specified in its TYPE field (TYPE = 1).

9.

Supported local entries in specific parts can be referenced by the use of fully qualified
references on SPCD entries in the model. A fully qualified reference (PartName.number)
is similar to the format of a numeric reference. PartName is the name of the part that
contains the referenced local entry (part names are defined on the BEGIN Bulk Data Entry
in the model). number is the identification number of a referenced local entry in the part
PartName. See Parts and Instances in the Users Guide for detailed information on the
use of fully qualified references.

10. This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2033


Proprietary Information of Altair Engineering

SPOINT
Bulk Data Entry
SPOINT Scalar-Point
Description
Defines scalar points.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SPOINT

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

(5)

(6)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

SPOINT

ID1

"THRU"

ID2

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SPOINT

18

16

THRU

47

99

THRU

128

Field

Contents

ID#

Scalar point identification number.

(10)

No default (0 < Integer)


Comments
1.

A scalar point defined by its appearance on the connection entry for a scalar element
(see the CELAS, CMASS, and CDAMP entries) need not appear on an SPOINT entry.

2034 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

All scalar point identification numbers must be unique with respect to all other scalar and
grid points.

3.

This entry is used primarily to define scalar points appearing in single-point or multipoint
constraint equations to which no scalar elements are connected.

4.

If the alternate format is used, all scalar points ID1 through ID2 are defined. ID1 must be
less than ID2.

5.

Alternate format can be combined with regular format, and it can span across
continuation lines.

6.

This card is represented as a node in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2035


Proprietary Information of Altair Engineering

STACK
Bulk Data Entry
STACK Stacking Information for Ply-Based Composite Definition
Description
Defines the stacking information and stacking sequence for ply-based composite definition.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

STAC K

ID

LAM

PLYID1

PLYID2

PLYID3

PLYID4

PLYID5

PLYID6

PLYID7

(10)

Optional continuation lines for substack definitions:


SUB

SID1

SNAME1

SPLYID1
1

SPLYID1
2

SPLYID1
3

SPLYID1
4

SPLYID1
5

SPLYID1
6

SPLYID1
7

...

...

...

...

...

...

...

Optional continuation lines for interface definitions:


INT

IPLYID11 IPLYID12

Example 1

Defines a stack consisting of 8 plies with the SMEAR option


(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

STAC K

SMEAR

1010100

1020100

1010200

1020200

1010300

1020300

1010400

1020400

(10)

Example 2

2036 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Defines a stack with substack and interface information. They ply layout is shown below.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

STAC K

SUB

top

11

12

13

14

SUB

left

21

22

23

24

SUB

right

31

32

33

34

SUB

middle

41

42

43

INT

14

21

INT

14

31

INT

21

41

INT

43

31

Altair Engineering

(9)

(10)

OptiStruct 13.0 Reference Guide 2037


Proprietary Information of Altair Engineering

Field

Contents

ID

Unique stack identification number.


No default (Integer > 0)

LAM

Laminate option. If blank, all plies must be specified and all stiffness terms are
developed. The following options are supported:
SYM:

Only plies on the bottom half of the composite lay-up need to be


specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom
to top.

MEM:

All plies must be specified, but only membrane terms are developed.

BEND:

All plies must be specified, but only bending terms are developed.

SMEAR:

All plies must be specified, stacking sequence is ignored, and MID1 is


set equal to MID2 on the derived equivalent PSHELL, while MID3, MID4,
TS/T, and 12I/T**3 are set to zero.

SMEARZ0:

All plies must be specified, stacking sequence is ignored. While the


laminate is still considered to be made of homogenized (smeared)
material, the effect of offset Z0 is taken into account. Hence, if Z0 is
not equal to -0.5*Thick, the equivalent PSHELL will include MID1,
MID2 and MID4. MID3 is still set to zero, that is no transverse shear
deformation is considered.

SMCORE:

All plies must be specified. The last ply specifies core properties and
the previous plies specify face sheet properties. The face sheet
properties are calculated without regard for stacking sequence; half of
the total face sheet thickness is then placed on top of the core, and
half is placed on the bottom, to produce a symmetric laminate.
Stiffness of the core is ignored while its density is included in inertia
calculations.

SYMEM:

Only plies on the bottom half of the composite lay-up need to be


specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom
to top. Only membrane terms are developed for the full laminate.

SYBEND:

Only plies on the bottom half of the composite lay-up need to be


specified. These plies are automatically symmetrically reflected to the
top half of the composite and given consecutive numbers from bottom
to top. Only bending terms are developed for the full laminate.

SYSMEAR:

Only plies on the bottom half of the composite lay-up need to be


specified. These plies are automatically symmetrically reflected to the

2038 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
top half of the composite and given consecutive numbers from bottom
to top. Stacking sequence is ignored, and MID1 is set equal to MID2
on the derived equivalent PSHELL, while MID3, MID4, TS/T and 12I/
T**3 are set to zero.
Default = blank, that is all plies must be specified (SYM, MEM, BEND, SMEAR,
SMCORE, SYMEM, SYBEND or SYSMEAR)

PLYID#

PLY identification number.


No default (Integer > 0)

SUB

SUB flag indicating that substack data is to follow.

SID#

Substack identification number.


No default (Integer > 0)

SNAME
#

Substack user-defined name.

SPLYID
#

PLY identification number.

INT

INT flag indicating that interface data is to follow.

No default (Character)

No default (Integer > 0)

IPLYID# PLY identification number.


No default (Integer > 0)
Comments
1.

The STACK card is used in combination with the PCOMPP and PLY cards to create
composite properties through the ply-based definition.

2.

Plies are listed from the bottom surface upward, in respect to the elements normal
direction. In the image below, (a) shows the stacking sequence for a non-symmetrical
laminate, and (b) shows the stacking sequence for a symmetrical laminate.

Altair Engineering

OptiStruct 13.0 Reference Guide 2039


Proprietary Information of Altair Engineering

3.

For convenience, element output for the SMEAR and SMCORE options includes both
homogenized shell stresses and individual ply stresses. However, because stacking
sequence is ignored in these options, individual ply stresses will only be valid in cases of
pure membrane deformation.

4.

Multiple instances of substack and interface continuations are allowed.

5.

This card is represented as a laminate in HyperMesh.

2040 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SUPORT
Bulk Data Entry
SUPORT Fictitious Support
Description
Defines determinate reaction degrees-of-freedom in a free body.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SUPORT

ID1

C1

ID2

C2

ID3

C3

ID4

C4

(10)

Example

(1)

(2)

(3)

SUPORT

16

215

(4)

(5)

Field

Contents

ID#

Grid point identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


C#

Component numbers.
No default (Any unique combination, with no embedded blanks, of
the integers 1 through 6 for grid points; or 0 for scalar points)

Comments
1.

The SUPORT entry specifies reference degrees-of-freedom for rigid body motion. It is not
intended to be used in place of a constraint (SPCi entry or PS on the GRID entry, for
example).

2.

SUPORT and/or SUPORT1 entries are required to activate inertia relief unless PARAM,
INREL, -2 is specified, then SUPORT and/or SUPORT1 entries are not required.

3.

Be careful not to spell SUPORT with two Ps.

Altair Engineering

OptiStruct 13.0 Reference Guide 2041


Proprietary Information of Altair Engineering

4.

Degrees-of-freedom specified on this entry cannot be defined as dependent degrees-offreedom in rigid body element or constrained in SPCi entry or PS on the GRID entry.

5.

An alternative to SUPORT is the SUPORT1 entry, which is requested by the SUPORT1 I/O
Options and Subcase Information command.

6.

This card is represented as a constraint load in HyperMesh.

2042 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SUPORT1
Bulk Data Entry
SUPORT1 Fictitious Support, Alternate Form
Description
Defines determinate reaction degrees-of-freedom in a free body. The SUPORT1 bulk data
entry must be requested in the I/O Options or Subcase Information sections by the SUPORT1
data selection command.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

SUPORT1

SID

ID1

C1

ID2

C2

ID3

C3

(9)

(10)

Example

(1)

(2)

(3)

(4)

SUPORT1

16

215

(5)

(6)

Field

Contents

SID

Set identification number. See comment 1.

(7)

(8)

(9)

(10)

No default (Integer > 0)


ID#

Grid point identification number.


No default (Integer > 0)

C#

Component numbers.
No default (Any unique combination, with no embedded blanks, of the
integers 1 through 6 for grid points; or 0 for scalar points)

Altair Engineering

OptiStruct 13.0 Reference Guide 2043


Proprietary Information of Altair Engineering

Comments
1.

SUPORT1 bulk data entries will not be used unless specifically selected in a subcase
definition by the SUPORT1 subcase information entry.

2.

SUPORT bulk data entries are applied in all subcases.

3.

The SUPORT1 bulk data entry must be requested in the I/O Options or Subcase
Information sections by the SUPORT1 data selection command. The degrees-of-freedom
specified on SUPORT1 will be combined with those on the SUPORT entry.

4.

Be careful not to spell SUPORT with two Ps.

5.

Degrees of freedom specified on this entry cannot be defined as dependent degrees-offreedom in rigid body element or constrained in SPCi entry or PS on the GRID entry.

6.

This card is represented as a constraint load in HyperMesh.

2044 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SURF
Bulk Data Entry
SURF Surface Definition
Description
Defines a face of a 2D or 3D element as part of a surface.
Format
(1)

(2)

(3)

(4)

(5)

SURF

SRFID

ELFAC E

EID1

GA1

GB1

NORMAL1

EID2

GA2

GB2

NORMAL2

EID3

...

...

...

...

...

(6)

(7)

(8)

(9)

(10)

Alternative Format (faceted surface)


In this format, surface is represented as collection of 3- or 4-noded polygons (facets). Each
facet is defined by 3 or 4 GRID IDs.
(1)

(2)

(3)

(4)

(5)

SURF

SRFID

FAC E

GA1

GB1

GC 1

GD1

GA2

GB2

GC 2

GD2

GA3

...

...

...

...

...

Altair Engineering

(6)

(7)

(8)

(9)

(10)

OptiStruct 13.0 Reference Guide 2045


Proprietary Information of Altair Engineering

Alternative Format (SET Format)


A surface may also be defined using a form of the SET bulk data entry. With this approach,
the surface is composed of all selected 2D elements and the external faces of all selected 3D
elements; that is, those faces that are not connected to any other 3D elements faces in the
model.
To use this format, the SURF keyword is used in place of the SET keyword and the TYPE must
be ELEM. All methods for defining a set of type ELEM are valid for this form of surface
definition. Refer to the SET bulk data entry.
Field

Contents

SRFID

Surface identification number.


No default (Integer > 0)

ELFACE

Flag indicating that the surface is composed of an element face.

EID#

2D or 3D element identification number.


No default (Integer > 0)

GA#

Identification number of a grid point at the corner of the desired face of a


3D element.
This field must be blank for 2D elements.
Default = blank (Integer > 0, blank)

GB#

Optional grid point identification number. Used to identify face of 3D


elements. See comment 1.
Default = blank (Integer > 0, blank)

NORMAL Identifies the normal direction for a face of the surface. The normal of a
face of a surface may be different from the normal of the underlying
elements.
0: normal matches the normal of the underlying element. For 3D elements,
this is pointing into the element.
1: normal direction is opposite of the underlying element. For 3D elements,
this is pointing out of the element.
Default = 0 (0 or 1)
Comments
1.

GB is used to identify faces of solid elements based on the following table:

2046 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

For HEXA elements:

Identification number of a grid point at a corner of the desired


face that is diagonally opposite GA.

For PENTA elements: Quad faces:

Tria faces:

2.

Identification number of a grid point at a corner of


the desired face that is diagonally opposite GA.
Leave blank.

For TETRA
elements:

Identification number of a grid point at the corner opposite the


desired face.

For PYRA elements:

Quad faces:

Leave blank

Tria faces:

GA and GB must specify the grids on the edge of the


face that borders the quadrilateral face, and the
grids must be ordered so that they define an inward
normal using the right hand rule.

This card is represented as a contactsurface in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2047


Proprietary Information of Altair Engineering

SWLDPRM
Bulk Data Entry
SWLDPRM Parameters for CWELD and CSEAM Connector Elements
Description
Defines values of parameters used during the CWELD and CSEAM connectivity search.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SWLDPR
M

PARAM1

VAL1

PARAM2

VAL2

PARAM3

VAL3

PARAM4

VAL4

PARAM5

VAL5

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

SWLDPRM

GSPROJ

15.0

PRTSW

(6)

(7)

(8)

(9)

(10)

Alternate Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SWLDPR
M

PARAM1

VAL1

PARAM2

VAL2

C TYPE1

PARAM3

VAL3

PARAM4

VAL4

C TYPE2

PARAM5

VAL5

PARAM6

VAL6

PARAM7

VAL7

(10)

-etc.-

Example (Alternate Format)

2048 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

SWLDPRM

GSPROJ

15.0

PRTSW

C WELD

GSMOVE

NREDIA

PROJTO
L

0.03

C SEAM

C NRAGLI

150.0

GSPROJ

20.0

SHOWAU
X

Field

Contents

PARAM#

Name of parameter.

VAL#

Value of parameter

CTYPE

Connector type keyword to control the element specific parameters.


Parameters following a keyword will only be applied to the element type
specified by the keyword.

(10)

Supported connector types: CWELD or CSEAM


While textual values are recommended for clarity, their integer equivalents will
also be read. The available parameters and their values are listed below (click
the parameter name for parameter descriptions).
Parameter

Value

CHKRUN

NO, 0, YES, or 1
Default = NO

CNRAGLI

90.0 < Real < 160.0 or -1.0


Default = 160.0

CNRAGLO

0.0 < Real < 90.0 or -1.0


Default = 20.0

GMCHK

NO, 0, YES, 1, FULL, or 2


Default = NO

GSMOVE

Integer > 0
Default = 0

Altair Engineering

OptiStruct 13.0 Reference Guide 2049


Proprietary Information of Altair Engineering

Parameter

Value

GSPROJ

0.0 < Real < 90.0 or -1.0


Default = 20.0

GSTOL

Real > 0.0


Default = 0.0

NREDIA

O < Integer < 4


Default = 0

PROJTOL

0.0 < Real < 0.5


Default = 0.05

PRTSW

NO, 0, YES, or 1
Default = NO

SHOWAUX

0, 1, 2, 3
Default = 0

Comments
1.

The SWLDPRM entry changes the default settings of parameters for the CWELD and
CSEAM connectivity entries. None of the parameters of this entry are required. The
default settings should be changed only for diagnostic and debug purposes. Only one
SWLDPRM entry is allowed in the bulk data section.

2.

Connectivities are created for the CSEAM element and for the CWELD element with
PARTPAT, ELPAT, ELEMID and GRIDID formats. With the parameters on this entry, you
can debug and alter the search algorithm which creates these connector elements.

3.

Before the presence of any keyword of the connector, that is CWELD and CSEAM, the
parameter set on the entry will be regarded as global, and it will be applied to all of the
connector elements unless it only serves a specific type of connector.

4.

Any parameter following a connector keyword will only be applied to the element type
specified by the keyword until the presence of another keyword.

5.

Blank fields are allowed in this entry. However, blank fields are not allowed between the
parameter name and the corresponding parameter value or between the connector
keyword and the parameter name followed. If the parameter name or the connector
keyword is located just before the continuation field, then the following content must be
placed in the first field after the continuation marker.

6.

Further detailed information about the individual connector elements can be found on the
pertinent CWELD and CSEAM bulk data entries.

7.

Some of the above parameters apply only to selected connector types. Such information
is provided within the detailed description of individual parameters.

2050 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, CHKRUN
Parameter
CHKRUN

Values

Description

NO, 0, YES, or 1
Default = NO

Stop or allow the run after the connectivities of all the


connector elements have been generated. This
parameter must be global, meaning it should be placed
before the presence of the first connector keyword.
If NO or 0, the solver will run to completion, unless other
errors are present.
If YES or 1, the solver will stop after connectivity of all
connector elements has been checked.

Altair Engineering

OptiStruct 13.0 Reference Guide 2051


Proprietary Information of Altair Engineering

SWLDPRM, CNRAGLI
Parameter
CNRAGLI

Values

Description

90.0 < Real < 180.0 For CSEAM element only. Minimum angle allowed
or -1.0
between the free edges (no other element shares
these edges) of shell elements EIDSA and EIDEA or
Default = 160.0
EIDSB and EIDEB. The CSEAM element will be rejected
if this minimum angle is violated. See the following
figure.

If < CNRAGLI, this CSEAM element is rejected (for


clarity suppose that the bold lines are the only couple
of free edges, while the others are connected with
shell elements not shown in this figure).
If CNRAGLI is set to -1.0, the program will skip the
checking of CNRAGLI.

2052 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, CNRAGLO
Parameter
CNRAGLO

Values

Description

0.0 < Real < 90.0


or -1.0
Default = 20.0

For CSEAM element only. Maximum angle allowed


between the normal vectors of EIDSA and EIDEA or
EIDSB and EIDEB. The CSEAM element will not be
generated if the angle between these two normal
vectors is greater than the value of CNRAGLO. This
prevents generating single CSEAM element across a very
curved shell configuration. See the following figure.

If > CNRAGLO, this CSEAM element is rejected. The


same check is also applied to the angle between the
normal vectors of EIDSB and EIDEB.
If CNRAGLO is set to -1.0, the program will skip the
checking of CNRAGLO.

Altair Engineering

OptiStruct 13.0 Reference Guide 2053


Proprietary Information of Altair Engineering

SWLDPRM, GMCHK
Parameter
GMCHK

Values

Description

NO, 0, YES, 1, FULL, or


2

A switch to perform geometry check for certain


types of connector elements (presently it only
applies to CSEAM).

Default = NO
If NO or 0, no geometry check.
If YES or 1, perform geometry checks for
connector elements.
If FULL or 2, perform geometry checks for
connector elements and output the shell element
ID(s) if an error is found.
If GMCHK=1 or 2, the program will check whether
the CSEAM element spans a cutout or a corner.
If the CSEAM element does, an error will be
issued.
If GMCHK=1 or 2 and GSPROJ > 0, the program
will check the angle between the normal vectors
of Shell A and Shell B. If the angle is larger than
the value defined by GSPROJ, an error will be
issued.
If GMCHK=1 or 2 and CNRAGLO > 0, the program
will check the angle between the normal vectors
of EIDSA and EIDEA or EIDSB and EIDEB. If the
angle is larger than the value defined by
CNRAGLO, an error will be issued.
If GMCHK=1 or 2 and CNRAGLI > 0, the program
will check the angle between the free edges of
shell elements EIDSA and EIDEA or EIDSB and
EIDEB. If the angle is smaller than the value
defined by CNRAGLI, an error will be issued.

2054 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, GSMOVE
Parameter
GSMOVE

Values

Description

Integer > 0
Default = 0

Altair Engineering

Maximum number of times GS for the CWELD (PARTPAT or


ELPAT format) or GS/GE for the CSEAM is moved in cases
when not all auxiliary points have projections onto the patch
of shells.

OptiStruct 13.0 Reference Guide 2055


Proprietary Information of Altair Engineering

SWLDPRM, GSPROJ
Parameter
GSPROJ

Values

Description

0.0 < Real < 90.0


or -1.0
Default = 20.0

Maximum angle allowed between the normal vectors of


Shell A and Shell B. Shell A and Shell B are located on
the two different shell surfaces that need to be
connected by the connector element. The connector
element will not be generated if the angle between
these two normal vectors is greater than the value of
GSPROJ. This prevents the generation of connector
elements between shell components that depart from
being parallel to each other. See the following figure.

If > GSPROJ, this connector element is rejected.


Meanwhile, for CSEAM, when locating possible
candidate shell elements to support the auxiliary points,
the program will also check the angle between the
normal vector of the candidate and the thickness
direction of the CSEAM element. If the angle is larger
than the value defined by GSPROJ, this candidate will
be ignored. If the ignored candidate is one of EIDSA,
EIDSB, EIDEA or EIDEB, a warning will be issued.
If GSPROJ is set to -1.0, the program will skip the
checking of GSPROJ.

2056 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, GSTOL
Parameter
GSTOL

Values

Description

Real > 0.0


Default = 0.0

Presently it only applies to CSEAM. Maximum distance


between GS-SA, GS-SB, GE-EA and GE-EB for CSEAM.
See the following figure.

If the distance is greater than GSTOL, then the


connector element will not be generated and an error will
be issued.
If GSTOL is set to 0.0, the program will skip the checking
of GSTOL.

Altair Engineering

OptiStruct 13.0 Reference Guide 2057


Proprietary Information of Altair Engineering

SWLDPRM, NREDIA
Parameter
NREDIA

Values

Description

0 < Integer < 4 Maximum number of times the diameter (which is used in
locating auxiliary points) is reduced by half when not all
Default = 0
auxiliary points have projections onto the patch of shells.
This parameter is for CWELD (PARTPAT and ELPAT) only.

2058 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, PROJTOL
Parameter
PROJTOL

Values

Description

0.0 < Real < 0.5


Default = 0.05

Altair Engineering

Tolerance to accept the projected points (from GS for


CWELD and from GS/GE for CSEAM) if the computed
coordinates of the projection point lies outside the shell
element but is located within PROJTOL(dimension of
the shell element). PROJTOL is only activated when a
search without PROJTOL finds no candidate shell to
build connectivity for a connector element. This
prevents the search from picking the wrong shell
element in cases when PROJTOL is not needed.

OptiStruct 13.0 Reference Guide 2059


Proprietary Information of Altair Engineering

SWLDPRM, PRTSW
Parameter
PRTSW

Values

Description

NO, 0, YES, or 1

Print diagnostic output for connector elements.

Default = NO

If NO or 0, diagnostic information is not output.


If YES or 1, diagnostic information is written to the .out
file.

2060 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

SWLDPRM, SHOWAUX
Parameter
SHOWAUX

Values

Description

NO, 0, YES, or 1
Default = NO

Output fictitious grids representing auxiliary points


generated for CWELD and fictitious hexa corner points
generated for CSEAM into a file which can be directly
imported into HyperMesh to visualize the connector
elements. For clarity of visualization, this file also
includes the eight-node CHEXA elements with corners
at respective auxiliary points for CWELD or at
respective fictitious hexa corner points for CSEAM.
For each CWELD element, this data will only be output
in cases where no error is issued before the definition
of auxiliary points. For the CSEAM element, this data
will only be output if all seam elements are built
successfully.
For CWELD, the root file name will be followed with
.weldaux.fem.
For CSEAM, the root file name will be followed with
.seamaux.fem. If SHOWAUX = YES, the
displacement/corner stress/grid point stress of the
fictitious hexa element will also be output into an H3D
file if requested.
If NO or 0, no data for the fictitious hexa will be
output.
If YES or 1, the fictitious grids and hexas will be
output (these are the final locations, including all the
adjustments due to connector element radius or
thickness).

Altair Engineering

OptiStruct 13.0 Reference Guide 2061


Proprietary Information of Altair Engineering

TABDMP1
Bulk Data Entry
TABDMP1 Modal Damping Table
Description
Defines modal damping as a tabular function of natural frequency.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABDMP
1

TID

TYPE

f1

g1

f2

g2

f3

g3

f4

g4

f5

g5

(7)

(8)

(9)

(10)

Example

(1)

(2)

TABDMP
1

2.5

(3)

(4)

(5)

(6)

0.01057

2.6

0.1362

ENDT

Field

Contents

TID

Table identification number.

(10)

No default (Integer > 0)


TYPE

Type of damping units.


Default = G (G, CRIT, or Q)

2062 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Natural frequency value in cycles per unit time.
No default (Real > 0.0)
Damping value.
No default (Real)

Comments
1.

Modal damping tables must be selected in the Subcase Information section, using the
SDAMPING command. This form of damping is used only in the modal method of frequency
response analysis.

2.

A METHOD statement must be present in the SUBCASE.

3.

The frequency values,


not both.

4.

Discontinuities may be specified between any two points except the two starting points
or two end points. For example, in Figure 1 discontinuities are allowed only between
points f2 through f7. Also, if g is evaluated at a discontinuity, then the average value of
g is used. In Figure 1, the value of g at f=f3 is g = (g3+g4)/2.

5.

At least one continuation entry must be specified.

6.

Any
or
that entry.

7.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

8.

The TABDMP1 uses the algorithm:

, must be specified in either ascending or descending order, but

entry may be ignored by placing 'SKIP' in either of the two fields used for

where, f is input to the table and g is returned. The table look-up


is performed
using linear interpolation within the table and linear extrapolation outside the table using
the two starting or end points. See Figure 1. No warning messages are issued if table
data is input incorrectly.

Altair Engineering

OptiStruct 13.0 Reference Guide 2063


Proprietary Information of Altair Engineering

Figure 1. Example of Table Extrapolation and Discontinuity

9.

The KDAMP option, on the PARAM card, may be used to switch between viscous and
structural damping. Viscous is the default and is used when PARAM, KDAMP is not
present.
KDAMP

Result

1 (default)

B matrix

-1

(1+ig)K matrix

10. If TYPE is 'G' or blank, the damping values


as follows:

If TYPE is 'CRIT', the damping values

are in units of equivalent viscous dampers

are in units of fraction of critical damping C/C0.

If TYPE is 'Q', the damping values


are in the units of amplification or quality factor, Q.
These constants are related by the following equations:

2064 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

11. To achieve identical displacements in Modal frequency response or Modal transient


analyses when the SDAMPING bulk data entry is used instead of PARAM, G , the steps
described here can be followed:
The TYPE field in the TABDMP1 bulk data entry should be set to CRIT. This TABDMP1 bulk
data entry is referenced by the SDAMPING subcase information entry.
Set the damping value (field
) in the TABDMP1 bulk data entry equal to half of the
value of PARAM, G (set the constant value to C/C0).
Set PARAM, KDAMP,-1.
12. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2065


Proprietary Information of Altair Engineering

TABLED1
Bulk Data Entry
TABLED1 Dynamic Load Tabular Function, Form 1
Description
Defines a tabular function for use in generating frequency-dependent and time-dependent
dynamic loads.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLED1

TID

XAXIS

YAXIS

x1

y1

x2

y2

x3

y3

x4

y4

x5

y5

(10)

Example

(1)

(2)

TABLED1

32

-3.0

(3)

(4)

(5)

(6)

(7)

(8)

6.9

2.0

5.6

3.0

5.6

ENDT

Field

Contents

TID

Table identification number.

(9)

(10)

No default (Integer > 0)


XAXIS

Specifies a linear or logarithmic interpolation for the x-axis. See


comment 6.
Default = LINEAR (LINEAR or LOG)

2066 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

YAXIS

Specifies a linear or logarithmic interpolation for the y-axis. See


comment 6.
Default = LINEAR (LINEAR or LOG)

x#, y#

Tabular values.
No default (Real or ENDT)

Comments
1.

xi must be in either ascending or descending order, but not both.

2.

Discontinuities may be specified between any two points except the two starting points
or two end points. For example, in Figure 1 discontinuities are allowed only between
points x2 through x7 . Also, if y is evaluated at a discontinuity, the average value of y is
used. In Figure 1, the value of y at x = x3 is y = (y3+y4)/2 .

3.

At least one continuation entry must be specified.

4.

Any x, y pair may be ignored by placing 'SKIP' in either of the two fields used for that
entry.

5.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

6.

The TABLED1 uses the algorithm:

where, x is input to the table and y is returned. The table look-up is performed using
interpolation within the table and linear extrapolation outside the table using the two
starting or end points. See Figure 1. The algorithms used for interpolation or
extrapolation are:

Altair Engineering

OptiStruct 13.0 Reference Guide 2067


Proprietary Information of Altair Engineering

where, xj and yj follow xi and yi.


No warning messages are issued if table data is input incorrectly.

Figure 1. Example of Table Extrapolation and Discontinuity

7.

Linear extrapolation is not used for Fourier transform methods. The function is zero
outside the range of the table.

8.

For frequency-dependent loads, x# is measured in cycles per unit time.

9.

Tabular values on an axis if X-Axis or Y-Axis = LOG must be positive. A fatal message will
be issued if an axis has a tabular value < 0.

2068 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

10. This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2069


Proprietary Information of Altair Engineering

TABLED2
Bulk Data Entry
TABLED2 Dynamic Load Tabular Function, Form 2
Description
Defines a tabular function for use in generating frequency-dependent and time-dependent
dynamic loads. Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLED2

TID

X1

x1

y1

x2

y2

x3

y3

x4

y4

x5

y5

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLED2

15

-10.5

1.0

-4.5

2.0

-4.2

2.0

2.8

7.0

6.5

SKIP

SKIP

9.0

6.5

ENDT

Field

Contents

TID

Table identification number.

(10)

No default (Integer > 0)


X1

Table parameter. See comment 6.


No default (Real)

2070 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

x#, y#

Tabular values.
No default (Real)

Comments
1.

xi must be in either ascending or descending order, but not both.

2.

Discontinuities may be specified between any two points except the two starting points
or two end points. For example, in Figure 1 discontinuities are allowed only between
points x2 through x7 . Also, if y is evaluated at a discontinuity, the average value of y is
used. In Figure 1, the value of y at x = x3 is y = (y3+y4)/2.

3.

At least one continuation entry must be specified.

4.

Any x, y pair may be ignored by placing 'SKIP' in either of the two fields used for that
entry.

5.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

6.

The TABLED2 uses the algorithm:

where, x is input to the table and y is returned. The table look-up is performed using
interpolation within the table and linear extrapolation outside the table using the two
starting or end points. See Figure 1. No warning messages are issued if table data is
input incorrectly.

Altair Engineering

OptiStruct 13.0 Reference Guide 2071


Proprietary Information of Altair Engineering

Figure 1. Example of Table Extrapolation and Discontinuity

7.

Linear extrapolation is not used for Fourier transform methods. The function is zero
outside the range of the table.

8.

For frequency-dependent loads, X1 and x# are measured in cycles per unit time.

9.

This card is represented as a loadcollector in HyperMesh.

2072 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TABLED3
Bulk Data Entry
TABLED3 Dynamic Load Tabular Function, Form 3
Description
Defines a tabular function for use in generating frequency-dependent and time-dependent
dynamic loads. Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLED3

TID

X1

X2

x1

y1

x2

y2

x3

y3

x4

y4

x5

y5

(10)

Example

(1)

(2)

(3)

(4)

TABLED3

15

126.9

30.0

2.9

2.9

3.6

(5)

(6)

(7)

(8)

4.7

5.2

5.7

ENDT

Field

Contents

TID

Table identification number.

(9)

(10)

No default (Integer > 0)


X1, X2

Table parameters.

Altair Engineering

OptiStruct 13.0 Reference Guide 2073


Proprietary Information of Altair Engineering

Field

Contents

x#, y#

Tabular values.
No default (Real)

Comments
1.

xii must be in either ascending or descending order, but not both.

2.

Discontinuities may be specified between any two points except the two starting points
or two end points. For example, in Figure 1 discontinuities are allowed only between
points x2 through x7 . Also, if y is evaluated at a discontinuity, the average value of y is
used. In Figure 1, the value of y at x = x3 is y = (y3+y4)/2.

3.

At least one continuation entry must be specified.

4.

Any x, y pair may be ignored by placing 'SKIP' in either of the two fields used for that
entry.

5.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

6.

The TABLED3 uses the algorithm:

where, x is input to the table and y is returned. The table look-up is performed using
interpolation within the table and linear extrapolation outside the table using the two
starting or end points. See Figure 1. No warning messages are issued if table data is
input incorrectly.

2074 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1. Example of Table Extrapolation and Discontinuity

7.

Linear extrapolation is not used for Fourier transform methods. The function is zero
outside the range of the table.

8.

For frequency-dependent loads, X1, X2, and x# are measured in cycles per unit time.

9.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2075


Proprietary Information of Altair Engineering

TABLED4
Bulk Data Entry
TABLED4 Dynamic Load Tabular Function, Form 4
Description
Defines the coefficients of a power series for use in generating frequency-dependent and
time-dependent dynamic loads. Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLED4

TID

X1

X2

X3

X4

A0

A1

A2

A3

A4

A5

A6

A7

A8

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

TABLED4

28

0.0

1.0

0.0

100

2.91

-0.0329

6.51e-5

0.0

-3.4-7

Field

Contents

TID

Table identification number.

(7)

(8)

(9)

(10)

ENDT

No default (Integer > 0)


X#

Table parameters.

2076 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

A#

Coefficients.
No default (Real)

Comments
1.

At least one continuation entry must be specified.

2.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

3.

TABLED4 uses the algorithm:

where, x is input to the table, y is returned and N is the number of pairs. Whenever x <
X3, use X3 for x; whenever x > X4, use X4 for x. There are N + 1 entries in the table.
There are no error returns from this table look-up procedure.
4.

For frequency-dependent loads, x# is measured in cycles per unit time.

5.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2077


Proprietary Information of Altair Engineering

TABFAT
Bulk Data Entry
TABFAT - Fatigue Loading Time History Definition
Description
Defines y values of each point on the loading time history.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABFAT

ID

y1

y2

y3

y4

y5

y6

y7

y8

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABFAT

0.000

-0.601

0.968

0.515

-0.263

-0.090

-0.582

-0.592

-0.877

-0.726

0.297

-0.899

-0.899

-0.165

0.907

0.936

-0.308

-0.308

-0.689

0.592

0.609

-0.600

-0.492

-0.492

-0.224

2078 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

(10)

Altair Engineering

Field

Contents

ID

Unique identification number.


No default (Integer > 0)

y#

Y value of each point on the loading time history curve.


No default (Real)

Comments
1.

The TABFAT ID may be referenced by a FATLOAD definition.

2.

This card is represented as a loadcollector in HyperMesh.

3.

Prior to OptiStruct version 11.0, TABFAT was named TABLEFAT.

Altair Engineering

OptiStruct 13.0 Reference Guide 2079


Proprietary Information of Altair Engineering

TABLEM1
Bulk Data Entry
TABLEM1 Material Property Table, Form 1
Description
Defines a tabular function for use in generating temperature-dependent material properties.
Format
(1)

(2)

TABLEM1

TID

x1

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

y1

x2

y2

x3

y3

-etc.-

"ENDT"

Example

(1)

(2)

TABLEM1

32

-3.0

(3)

(4)

(5)

(6)

(7)

(8)

6.9

2.0

5.6

3.0

5.6

ENDT

Field

Contents

TID

Table identification number.

(9)

(10)

(Integer > 0)
xi, yi

Tabular values.
(Real)

"ENDT"

Flag indicating the end of the table.

2080 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

xi must be in either ascending or descending order, but not both.

2.

Discontinuities may be specified between any two points except the two start points or
two end points. For example, in the figure below, discontinuities are allowed only
between points x2 through x7 . Also, if y is evaluated at a discontinuity, then the average
value of y is used. In the figure, the value of y at x = x3 is y = (y3 +y4)/2.

3.

At least one continuation entry must be specified.

4.

Any xi- yi pair may be ignored by placing 'SKIP' in either of the two fields.

5.

The end of the table is indicated by the existence of "ENDT" in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag "ENDT".

6.

The TABLEM1 uses the algorithm (see comment 7):

y= yT(x)
where, x is input to the table and y is returned. The table look-up is performed using
linear interpolation within the table and linear extrapolation outside the table using the
two start or end points (see figure). No warning messages are issued, if the table data is
input incorrectly.

Example of table extrapolation and discontinuity

7. In a nonlinear heat transfer analysis, TABLEM1 uses the following algorithm:

y = zyT(x)
Where. x is input to the table, y is returned, and z is supplied from the MAT4 entry.
8.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2081


Proprietary Information of Altair Engineering

TABLEM2
Bulk Data Entry
TABLEM2 Material Property Table, Form 2
Description
Defines a tabular function for use in generating temperature-dependent material properties.
Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

TABLEM2

TID

X1

x1

y1

(4)

(5)

(6)

(7)

(8)

(9)

x2

y2

x3

y3

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLEM2

15

-10.5

1.0

-4.5

2.0

-4.5

2.0

2.8

7.0

6.5

SKIP

SKIP

9.0

6.5

ENDT

Field

Contents

TID

Table identification number.

(10)

(Integer > 0)
X1

Table parameter.
(Real)

2082 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

xi, yi

Tabular values.
(Real)

Comments
1.

xi must be in either ascending or descending order, but not both.

2.

Discontinuities may be specified between any two points except the two starting points
or two end points. For example, in the figure below, discontinuities are allowed only
between points x2 through x7 . Also, if y is evaluated at a discontinuity, then the average
value of y is used. In the figure, the value of y at x = x3 is y = (y3+y4)/2 .

3.

At least one continuation entry must be specified.

4.

Any xi-yi pair may be ignored by placing 'SKIP' in either of the two fields.

5.

The end of the table is indicated by the existence of "ENDT" in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag "ENDT".

6.

The TABLEM2 uses the algorithm:

y= zyT(x X1)
where, x is input to the table, y is returned, and z is supplied from the MATi entry. The
table look-up is performed using linear interpolation within the table and linear
extrapolation outside the table using the two start or end points (see figure). No warning
messages are issued if table data is input incorrectly.

Example of table extrapolation and discontinuity

Altair Engineering

OptiStruct 13.0 Reference Guide 2083


Proprietary Information of Altair Engineering

7.

This card is represented as a loadcollector in HyperMesh.

2084 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TABLEM3
Bulk Data Entry
TABLEM3 Material Property Table, Form 3
Description
Defines a tabular function for use in generating temperature-dependent material properties.
Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

(4)

TABLEM3

TID

X1

X2

x1

y1

x2

(5)

(6)

(7)

(8)

(9)

y2

x3

y3

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

TABLEM3

62

126.9

30.0

2.9

2.9

3.6

(5)

(6)

(7)

(8)

4.7

5.2

5.7

ENDT

Field

Contents

TID

Table identification number.

(9)

(10)

(Integer > 0)
X1, X2

Table parameters. See comment 6.

xi, yi

Tabular values.
(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 2085


Proprietary Information of Altair Engineering

Comments
1.

Tabular values for xi must be specified in either ascending or descending order, but not
both.

2.

Discontinuities may be specified between any two points except the two start points or
two end points. For example, in the figure below, discontinuities are allowed only
between points x2 through x7 . Also, if y is evaluated at a discontinuity, then the average
value of y is used. In the figure, the value of y at x = x3 is y = (y3+y4)/2 .

3.

At least one continuation entry must be specified.

4.

Any xi-yi pair may be ignored by placing 'SKIP' in either of the two fields.

5.

The end of the table is indicated by the existence of "ENDT" in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag "ENDT".

6.

TABLEM3 uses the algorithm:

where, x is input to the table, y is returned and z is supplied from the MATi entry. The
table look-up is performed using linear interpolation within the table and linear
extrapolation outside the table using the two starting or end points (see figure). No
warning messages are issued if table data is input incorrectly.

Example of table extrapolation and discontinuity

7.

This card is represented as a loadcollector in HyperMesh.

2086 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TABLEM4
Bulk Data Entry
TABLEM4 Material Property Table, Form 4
Description
Defines coefficients of a power series for use in generating temperature-dependent material
properties. Also contains parametric data for use with the table.
Format
(1)

(2)

(3)

(4)

(5)

(6)

TABLEM4

TID

X1

X2

X3

X4

A0

A1

A2

A3

A4

(7)

(8)

(9)

A5

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

TABLEM4

28

0.0

1.0

0.0

100.

2.91

-0.0329

6.51-5

0.0

-3.4-7

Field

Contents

TID

Table identification number.

(7)

(8)

(9)

(10)

ENDT

(Integer > 0)
Xi

Table parameters.

Ai

Coefficients.
(Real)

Altair Engineering

OptiStruct 13.0 Reference Guide 2087


Proprietary Information of Altair Engineering

Comments
1.

At least one continuation entry must be specified.

2.

The end of the table is indicated by the existence of "ENDT" in the field following the last
entry. An error is detected if any continuations follow the entry containing the end-oftable flag "ENDT".

3.

TABLEM4 uses the algorithm:

where, x is input to the table, y is returned, and z is supplied from the MATi entry.
Whenever x < X3 , use X3 for x; whenever x > X4 , use X4 for x. There are N + 1 entries in
the table. There are no error returns from this table look-up procedure.
4.

This card is represented as a loadcollector in HyperMesh.

2088 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TABLES1
Bulk Data Entry
TABLES1 Material Property Tabular Function, Form 1
Description
Defines a tabular function for use as stress-strain curve in elasto-plastic material properties
MATS1, MATX33, MATX65, MATHF, as well as material curve in nonlinear material properties
MATX36, MATX42, and MATX70.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TABLES1

TID

x1

y1

x2

y2

x3

y3

x4

y4

x5

y5

(9)

(10)

Example

(1)

(2)

TABLES1

32

-3.0

(3)

(4)

(5)

(6)

(7)

(8)

6.9

2.0

5.6

3.0

5.6

ENDT

Field

Contents

TID

Table identification number.

(10)

No default (Integer > 0)


x#, y#

Tabular values.
No default (Real, or ENDT)

Comments
1.

xi must be in either ascending or descending order, but not both.

Altair Engineering

OptiStruct 13.0 Reference Guide 2089


Proprietary Information of Altair Engineering

2.

Discontinuities between any two points except the two starting points or two end points.
For example, in Figure 1 discontinuities are allowed only between points x2 through x7 .
Also, if y is evaluated at a discontinuity, the average value of y is used. In Figure 1, the
value of y at x = x3 is y = (y3+y4)/2 .

3.

At least one continuation entry must be specified.

4.

Any x, y pair may be ignored by placing 'SKIP' in either of the two fields used for that
entry.

5.

The end of the table is indicated by the existence of 'ENDT' in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag 'ENDT'.

6.

The TABLES1 uses the algorithm:

where, x is input to the table and y is returned. The table look-up is performed using
interpolation within the table and linear extrapolation outside the table using the two
starting or end points. See Figure 1. The algorithms used for interpolation or
extrapolation is:

where, xj and yj follow xi and yi.


7.

For TABLES1 referenced by elasto-plastic material property MATS1, additional


requirements apply. See the description of MATS1 for details.

2090 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Figure 1. Example of Table Extrapolation and Discontinuity

8.

Linear extrapolation is not used for Fourier transform methods. The function is zero
outside the range of the table.

9.

For frequency-dependent loads, x# is measured in cycles per unit time.

10. Some warning or error messages are issued if table data in input incorrectly. However,
since TABLES1 can serve different and distinct purposes, error checking is limited.

Altair Engineering

OptiStruct 13.0 Reference Guide 2091


Proprietary Information of Altair Engineering

TABLEST
Bulk Data Entry
TABLEST Material Property Temperature-Dependence Table
Description
Specifies the material property tables for elasto-plastic, temperature-dependent materials.
Format
(1)

(2)

TABLEST

TID

T1

(3)

(4)

(5)

(6)

(7)

TID1

T2

TID2

T3

-etc.-

(8)

(9)

(10)

(9)

(10)

Example

(1)

(2)

TABLEST

101

150.0

(3)

(4)

(5)

(6)

10

175.0

20

ENDT

Field

Contents

TID

Table identification number.

(7)

(8)

(Integer > 0)
Ti

Temperature values.
(Real)

TIDi

Table identification numbers of TABLES1 entries.


(Integer > 0)

2092 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

TIDi must be unique with respect to all TABLES1 and TABLEST table identification
numbers.

2.

Temperature values must be listed in ascending order.

3.

The end of the table is indicated by the existence of ENDT in either of the two fields
following the last entry. An error is detected if any continuations follow the entry
containing the end-of-table flag ENDT.

4.

This table is referenced by MATS1 entries that define elasto-plastic (TYPE = "PLASTIC")
materials.

Altair Engineering

OptiStruct 13.0 Reference Guide 2093


Proprietary Information of Altair Engineering

TABRND1
Bulk Data Entry
TABRND1 Power Spectral Density Table
Description
Defines power spectral density as a tabular function of frequency for use in random analysis.
Referenced on the RANDPS entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TABRND1

ID

XAXIS

YAXIS

blank

blank

blank

blank

blank

f1

g1

f2

g2

f3

g3

f4

g4

Example

(1)

(2)

TABRND1

2.5

(3)

(4)

(5)

(6)

.01057

2.6

.01362

ENDT

(7)

(8)

(9)

(10)

etc.

Field

Contents

ID

Table identification number.


(Integer > 0)

XAXIS

Specifies a linear or logarithmic interpolation for the x-axis. See comment


6.
Default = LINEAR (LINEAR or LOG)

2094 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

YAXIS

Specifies a linear or logarithmic interpolation for the y-axis. See comment


6.
Default = LINEAR (LINEAR or LOG)

fi

Frequency value in cycles per unit time.


(Real > 0.0)

gi

Power Spectral Density.


(Real)

Comments
1.

The fi must be in either ascending or descending order, but not both.

2.

Jumps between two points (

3.

At least two entries must be present.

4.

Any f-g entry may be ignored by placing the BCD string "SKIP" in either of the two field
used for that entry.

5.

The end of the table is indicated by the existence of the BCD string "ENDT" in either of
the two fields following the last entry. An error is detected if any continuations follow
the entry containing the end-of-table flag "ENDT".

6.

The TABRND1 mnemonic infers the use of the algorithm:

) are allowed, but not at the end points.

G = g T(F)
where, F is input to the table and G is returned. The table look-up gT(f) is performed
using linear extrapolation outside the table using the last two end points at the
appropriate table end. At jump points, the average gT(F) is used. There are no error
returns from this table look-up procedure.

Altair Engineering

OptiStruct 13.0 Reference Guide 2095


Proprietary Information of Altair Engineering

TEMP
Bulk Data Entry
TEMP Grid Point Temperature Field
Description
Defines temperature at grid points for determination of Thermal Loading and Stress recovery.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TEMP

SID

blank

{N.C .}

Example

(1)

(2)

(3)

(4)

(5)

(6)

TEMP

94

316.2

49

219.8

Field

Contents

SID

LOAD set identification.

(7)

(8)

(9)

(10)

(Integer > 0)
G

Grid point identification number.


(Integer > 0)

Temperature.
(Real)

Comments
1.

Temperature sets may be selected for use in a subcase by the TEMPERATURE(LOAD) or


TEMPERATURE(BOTH) subcase information entry.

2.

From one to three grid point temperatures may be defined on a single entry.

2096 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

In versions of OptiStruct prior to 8.0, thermal loads were selected in the Subcase
Information section using the LOAD data selector. In version 8.0, the TEMPERATURE data
selector was added to perform this function. It is possible to revert to the old behavior
mode by setting the LOADTEMP option to SHAREID in the OptiStruct Configuration File.

4.

This card is represented as a temperature load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2097


Proprietary Information of Altair Engineering

TEMPD
Bulk Data Entry
TEMPD Grid Point Temperature Field Default
Description
Defines a temperature value for all grid points of the structural model that have not been
given a temperature on a TEMP entry.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TEMPD

SID

SID

SID

SID

(10)

Example

(1)

(2)

(3)

TEMPD

216.3

(4)

Field

Contents

SID

LOAD set identification.

(5)

(6)

(7)

(8)

(9)

(10)

(Integer > 0)
T

Default temperature value.


(Real)

Comments
1.

Temperature sets may be selected for use in a subcase by the TEMPERATURE(LOAD) or


TEMPERATURE(BOTH) subcase information entry.

2.

From one to four default temperatures may be defined on a single entry.

2098 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

In versions of OptiStruct prior to 8.0, thermal loads were selected in the Subcase
Information section using the LOAD data selector. In version 8.0, the TEMPERATURE data
selector was added to perform this function. It is possible to revert to the old behavior
mode by setting the LOADTEMP option to SHAREID in the OptiStruct Configuration File.

4.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2099


Proprietary Information of Altair Engineering

TIC
Bulk Data Entry
TIC Transient and Explicit Analysis Initial Condition
Description
Defines values for the initial conditions of variables used in structural transient analysis and
explicit analysis. Both displacement and velocity values may be specified at independent
degrees-of-freedom.
Format
(1)

(2)

(3)

(4)

(5)

(6)

TIC

SID

U0

V0

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

TIC

100

10

0.1

0.5

Field

Contents

SID

Set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
G

Grid or scalar point identification number. See comment 4.


(Integer > 0)

Component numbers.
(Any one of the integers 1 through 6 for grid points, integer zero or blank for
scalar points)

U0

Initial displacement. Not applicable in geometric nonlinear analysis.

2100 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Real or blank)

V0

Initial velocity.
(Real or blank)

Comments
1.

Transient analysis initial condition sets must be selected with the IC subcase information
command.

2.

If no TIC set is selected in the Subcase Information section, all initial conditions are
assumed to be zero.

3.

Initial conditions for coordinates not specified on TIC entries will be assumed to be zero.

4.

In direct transient analysis, wherein the TIC bulk data entry is selected by an IC subcase
information command, G may reference only grid or scalar points.

5.

Initial displacement definition is not applicable in explicit analysis. If U0 is defined, a fatal


error message will be issued.

6.

The initial conditions for the independent degrees-of-freedom specified by this bulk data
entry are distinct from, and may be used in conjunction with, the initial conditions for the
enforced degrees-of-freedom specified by NLOAD1, TLOAD1 and/or TLOAD2 bulk data
entries.

7.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

8.

Each degree-of-freedom (grid/component pair: G#/C#) should define a unique value for
U0 and/or V0 within any TIC ID set, but U0 and V0 may be specified on separate TIC
cards. When multiple cards with the same degree-of-freedom are present, only non-zero
values for U0 and V0 are used by the solver. When two non-zero values are defined for
U0 or for V0 for the same degree-of-freedom, a fatal error message will be issued, even if
values match.

9.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2101


Proprietary Information of Altair Engineering

TICA
Bulk Data Entry
TICA Explicit Analysis Initial Velocity Relative to an Axis
Description
Defines values for the initial velocity of a set of grids along and about an axis for explicit
analysis.
Format
(1)

(2)

(3)

(4)

(5)

TIC A

SID

GSID

VT

VR

GA/XA

YA

ZA

GB/XB

(6)

(7)

YB

ZB

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

TIC A

100

10

3.0

4.0

123

0.0

Field

Contents

SID

Set identification number.

(6)

(7)

0.0

1.0

(8)

(9)

(10)

(Integer > 0)
GSID

Grid point set identification number.


Default = all grids in the model (blank or Integer > 0)

VT

Initial velocity along the axis.


(Real)

2102 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

VR

Initial velocity about the axis.


(Real)

GA/ XA,
YA, ZA

Axis origin. These fields define the origin of the axis. The point may be
defined by entering a grid ID in the GA field or by entering X, Y, and Z
coordinates in the XA, YA, and ZA fields; these coordinates will be in the
basic coordinate system.
Default is the origin of the basic system (Real in all three fields or Integer in
first field)

GB/ XB,
YB, ZB

Direction of vector for axis definition. These fields define a point. The
vector goes from the anchor point to this point. The point may be defined
by entering a grid ID in the GB field or by entering X, Y, and Z coordinates in
the XB, YB, and ZB fields; these coordinates will be in the basic coordinate
system.
No default (Real in all three fields or Integer in first field)

Comments
1.

Explicit analysis initial condition sets must be selected with the Subcase Information
command IC = SID. It can only be selected in explicit subcases which are defined by an
ANALYSIS = NLGEOM subcase entry.

2.

TICA is primarily used for simulating the uniform rotation of a structure about an axis by
defining VR and an axis. A helical (or spiral) shaped motion can also be achieved by
defining VR, VT and an axis.

3.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2103


Proprietary Information of Altair Engineering

TIE
Bulk Data Entry
TIE Tied Definition
Description
Defines a tied contact.
Format
(1)

(2)

(3)

TIE

TID

(4)

(5)

(6)

SSID

MSID

(7)

(8)

SRC HDIS

ADJUST

(7)

(8)

(9)

(10)

DISC RET

Example

(1)

(2)

TIE

(3)

(4)

(5)

(6)

(9)

(10)

0.01

N25

Field

Contents

TID

Tied interface identification number. See comment 1.


(Integer > 0)

SSID

Identification number of slave entity. See comments 3 and 10.


(Integer > 0)

MSID

Identification number of master entity. See comments 4 and 11.


(Integer > 0)

2104 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

SRCHDIS Search distance criterion for creating contact condition. When specified,
only slave nodes that are within SRCHDIS distance from master surface will
have contact condition checked.
Default = All slave nodes checked (Real > 0 or blank)
ADJUST

Adjustment of slave nodes onto the master surface at the start of a


simulation.
<NO, AUTO, Real > 0.0, or Integer > 0>
Default = NO.
NO no adjustment.
AUTO A real value equal to 5% of the average edge length on the master
surface is internally assigned as the depth criterion (see Comment 7).
Real > 0.0 Value of the depth criterion which defines the zone in which a
search is conducted for slave nodes (for which contact elements have been
created). These slave nodes (with created contact elements) are then
adjusted onto the master surface. The assigned depth criterion is used to
define the searching zone in the pushout direction (see Comment 7).
Integer > 0 Identification number of a SET entry with TYPE = GRID.
Only the nodes on the slave entity, which also belong to this SET will be
selected for adjustment.

DISCRET Discretization approach type for the construction of contact elements.


<N2S, S2S>
Default = N2S.
N2S node-to-surface discretization
S2S surface-to-surface discretization

Comments
(Nonlinear quasi-static analysis)
1.

TIE contact needs to keep a unique ID from all CONTACT definitions.

2.

The TIE contact is constructed by searching for each slave node for a respective facet of
the master surface, which contains the normal projection of the slave and is within
SRCHDIS distance from the slave node. If no master segment with normal projection is
found, then the nearest segment is picked if the direction from slave to master is within a
certain angle (30 degrees) relative to the normal to the master segment. Having found a
feasible master segment for the slave node, a tie element is created.

Altair Engineering

OptiStruct 13.0 Reference Guide 2105


Proprietary Information of Altair Engineering

Figure 1: C reation of a TIE element

If the surface-to-surface (DISCRET=S2S) discretization approach is selected, the


CONTACT interface is constructed by searching, for each facet of the slave surface,
respective facets of the master surface which contain the normal projection of sample
points on the slave facet and is within SRCHDIS distance from the sample points. For a
slave node, a contact element is created with the surrounding slave facets and the
master facets found by projection of the sample points on the slave facets (Figure 2).

Figure 2: C reation of a contact element (surface-to-surface discretization)

3.

The slave entity (SSID) always consists of grid nodes. It may be specified as:
a set of grid nodes defined using SET card.
a surface defined using SURF card (the slave nodes are picked from the respective
nodes of the SURF faces).
a set of elements (shells or solids) defined using SET card. Slave nodes are picked
from the respective nodes of the elements in the set. For 3D solids, only nodes on the
surface of the solid body are selected; internal nodes are not considered.
DISCRET = N2S is recommended if the slave entity is a set of grids (nodes) or a set of
solid elements.

4.

The master entity (MSID) may be defined as:


a surface defined using SURF card.
a set of elements (shells or solids) defined using SET card. For sets of 3D solids,

2106 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

element faces on the surface are automatically found and selected as master surface.
5.

TIE element is created of a same structure as FREEZE CONTACT element. TIE element
enforces zero relative motion on the contact surface the contact gap opening remains
fixed at the original value and the sliding distance is forced to be zero. Also, rotations at
the slave node are matched to the rotations of the master patch.

6.

Presently one TIE element is created for each slave node. This assures reasonably
efficient numerical computations without creating an excessive number of tie elements.
However, this may require special handling in some cases, such as when a master surface
wraps around the slave set. In such cases, switching the role of slave and master may
be recommended. Alternatively, multiple TIE elements can be created in order to cover all
possible directions of relative motion (a simplified illustration is shown in Figure 3).

Figure 3: Special case - Master surface wraps around a slave node set.

7.

The adjustment of slave nodes doesnt create any strain in the model. If DISCRET=N2S is
selected, it is treated as a change in the initial model geometry. If DISCRET=S2S is
selected, it is treated as a change in the initial contact opening/penetration.
If a node on the slave entity lies outside the projection zone of the master surface, it will
always be skipped during adjustment since no contact element has been constructed for
it.
If different contact interfaces involve the same nodes, nodal adjustment definitions are
processed sequentially in the order of identification numbers of the contact interfaces.
Care must be taken to avoid conflicts between the nodal adjustments; otherwise, contact
element errors or lack of compliance may occur.
a) The ADJUST field must be set to NO for self-contact.
b) If a real value (the searching depth criterion for adjustment) is input for the ADJUST
field, a searching zone for adjustment is defined. The slave nodes in this searching
zone, for which contact elements have been created, will be adjusted. If ADJUST is
larger than or equal to SRCHDIS, all the slave nodes, for which contact elements have
been created, will be adjusted.

Altair Engineering

OptiStruct 13.0 Reference Guide 2107


Proprietary Information of Altair Engineering

Figure 4: An illustration depicting how ADJUST works.

Depth Criterion
The depth criterion (A non-negative real value for ADJUST) is used to define the searching
zone for adjustment as shown in Figure 4. This searching zone is created in the pushout
direction up to a distance equal to the value of the ADJUST field. The slave nodes within
the searching zone (with defined contact elements) are then considered for adjustment
based on the rules specified within this comment (Comment 7).
c) If the ADJUST field is set to an integer value (the identification number of a grid SET
entry), the nodes shared by the slave entity and the grid SET will be checked for
contact creation, that is SRCHDIS will be ignored for these nodes, and then adjusted if a
projection is found. The nodes belonging to the grid SET but not to the slave entity will
be simply ignored.
8.

This card is represented as a group in HyperMesh.

(Geometric nonlinear analysis (ANALYSIS = NLGEOM subcases))


9.

TIE is implemented as a Tied Contact in geometric nonlinear subcases. A geometric


nonlinear subcase is one that has an ANALYSIS = NLGEOM entry in the subcase
definition.

10. The slave entity (SSID) always consists of grid nodes. It may be specified as:

2108 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

a set of grid nodes defined using SET card.


a surface defined using SURF card (the slave nodes are picked from the respective
nodes of the SURF faces).
a set of elements (shells or solids) defined using SET card. Slave nodes are picked
from the respective nodes of the elements in the set. For 3D solids, only nodes on the
surface of the solid body are selected; internal nodes are not considered.
11. The master entity (MSID) may be defined as:
a surface defined using SURF card.
a set of elements (shells or solids) defined using SET card.
12. This card is represented as a group in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2109


Proprietary Information of Altair Engineering

TLOAD1
Bulk Data Entry
TLOAD1 Transient Response Dynamic Excitation, Form 1
Description
Defines a time-dependent dynamic load or enforced motion of the form:

for use in transient response analysis.


Where,

f(t) is the time-dependent dynamic load or enforced motion.

A defines the amplitude of the dynamic excitation and is referenced by the EXCITEID field.
(F)t is a user-defined function that defines the time-variant nature of f(t). It is specified by
referencing a predefined TABLEDi entry in the TID field.
is the time delay defined in the DELAY field.
Format
(1)

(2)

(3)

(4)

(5)

(6)

TLOAD1

SID

EXC ITEID

DELAY

TYPE

TID

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

TLOAD1

(4)

(5)

(6)

LOAD

13

Field

Contents

SID

Set identification number.

(7)

(8)

(9)

(10)

(Integer > 0)

2110 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

EXCITEID

Identification number of the DAREA, SPCD, FORCEx, MOMENTx,


PLOADx, RFORCE, QVOL, QBDY1 or GRAV entry set that defines {A}.
See comments 2 and 3.
(Integer > 0)

DELAY

Defines time delay . If it is a non-zero integer, it represents the


identification number of DELAY bulk data entry that defines . If it is
real, then it directly defines the value of that will be used for all
degrees-of-freedom that are excited by this dynamic load entry. See
comment 7.
(Integer > 0, real or blank)

TYPE

Defines the type of the dynamic excitation. See comments 2 and 3.


(Integer, character or blank; Default = 0)

TID

Identification number of TABLEDi entry that gives F(t).


(Integer > 0)

Comments
1.

Dynamic excitation sets must be selected with the subcase information command
DLOAD=SID.

2.

The type of dynamic excitation is specified by TYPE (field 5) based on the following table:
TYPE
TYPE of Dynamic Excitation
Integer

Character

L, LO, LOA, or Applied load (force or moment)


LOAD
(Default)

D, DI, DIS, or
DISP

V, VE, VEL, or Enforced velocity; EXCITEID references SPC/SPCD data.


VELO

A, AC, ACC,
or ACCE

Altair Engineering

Enforced displacement or temperature; EXCITEID references


SPC/SPCD data.

Enforced acceleration; EXCITEID references SPC/SPCD


data.

OptiStruct 13.0 Reference Guide 2111


Proprietary Information of Altair Engineering

3.

TYPE (field 5) also determines the manner in which EXCITEID (field 3) is used by the
program as described below.
Excitation specified by TYPE is applied load. The EXCITEID must reference DAREA,
FORCEx, MOMENTx, PLOAD, RFORCE, GRAV, QVOL or QBDY1 entries.
Excitation specified by TYPE is enforced motion. The EXCITEID must reference SPC/SPCD
entries.
TYPE = 1 must be specified if the EXCITEID field references SPCD data used in transient
heat transfer analysis to define time-dependent thermal boundary conditions.

4.

TLOAD1 loads may be combined with TLOAD2 loads only by specification on a DLOAD
entry. That is, the SID on a TLOAD1 entry may not be the same as that on a TLOAD2
entry.

5.

SID must be unique for all TLOAD1, TLOAD2, RLOAD1, and RLOAD2 entries.

6.

If TLOAD1 entries are selected for Fourier analysis, then the time-dependent loads on the
TLOAD1 entries are transformed to the frequency domain. Then the analysis is performed
as a frequency response analysis, but the solution and the output are converted to and
printed in the time domain.

7.

If DELAY is blank or zero,

8.

When EXCITEID refers to an SPCD entry, the modal space will be augmented with
displacement vector(s) from linear static analysis with unit prescribed displacement at
each of the SPCD degrees-of-freedom. EXCITEID cannot reference the LOAD and
LOADADD bulk data entries.

9.

This card is represented as a loadcollector in HyperMesh.

will be zero.

2112 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TLOAD2
Bulk Data Entry
TLOAD2 Transient Response Dynamic Excitation, Form 2
Description
Defines a time-dependent dynamic excitation or enforced motion of the form:

for use in a transient response analysis, where

Where,
is the time-dependent dynamic load or enforced motion.

A defines the amplitude of the dynamic excitation and is referenced by the EXCITEID field.
is the time delay defined in the DELAY field.
T1 and T2 are time constants defined in the T1 and T2 fields.
B, C,
and
are the growth coefficient, exponential coefficient, frequency and phase angle
respectively and are defined in the corresponding B, C, F and P fields.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

TLOAD2

SID

EXC ITEID

DELAY

TYPE

T1

T2

(10)

Example

(1)

(2)

(3)

TLOAD2

10

Altair Engineering

(4)

(5)

(6)

(7)

(8)

2.1

4.7

12.0

(9)

(10)

OptiStruct 13.0 Reference Guide 2113


Proprietary Information of Altair Engineering

2.0

Field

Contents

SID

Set identification number.


(Integer > 0)

EXCITEID

Identification number of the DAREA, SPCD, FORCEx, MOMENTx,


PLOADx, RFORCE, QVOL, QBDY1 or GRAV entry set that defines {A}.
See comments 2 and 3.
(Integer > 0)

DELAY

Defines time delay . If it is a non-zero integer, it represents the


identification number of DELAY bulk data entry that defines . If it is
real, then it directly defines the value of that will be used for all
degrees-of-freedom that are excited by this dynamic load entry. See
comment 4.
(Integer > 0, real or blank)

TYPE

Defines the type of the dynamic excitation. See comments 2 and 3.


(Integer, character or blank; Default = 0)

T1

Time constant.
(Real > 0.0)

T2

Time constant.
(Real; T2>T1)

Frequency in cycles per unit time.


(Real > 0.0; Default = 0.0)

Phase angle in degrees.


(Real; Default = 0.0)

Exponential coefficient.

2114 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
(Real; Default = 0.0)

Growth coefficient.
(Real; Default = 0.0)

Comments
1.

Dynamic excitation sets must be selected with the subcase information command with
DLOAD=SID.

2.

The type of dynamic excitation is specified by TYPE (field 5) based on the following
table:
TYPE
TYPE of Dynamic Excitation
Integer
0

3.

Character
L, LO, LOA,
or LOAD

Applied load (force or moment)

D, DI, DIS,
or DISP

Enforced displacement or temperature; EXCITEID references


SPC/SPCD data.

V, VE, VEL,
or VELO

Enforced velocity; EXCITEID references SPC/SPCD data.

A, AC, ACC,
or ACCE

Enforced acceleration; EXCITEID references SPC/SPCD data.

(Default)

TYPE (field 5) also determines the manner in which EXCITEID (field 3) is used by the
program as described below.
If the type of dynamic excitation specified by TYPE is applied load, then EXCITEID must
reference DAREA, FORCEx, MOMENTx, PLOAD, RFORCE, GRAV, QVOL or QBDY1 entries.
If the type of dynamic excitation specified by TYPE is enforced motion, then EXCITEID
must reference SPC/SPCD entries.
TYPE = 1 must be specified if the EXCITEID field references SPCD data used in transient
heat transfer analysis to define time-dependent thermal boundary conditions

4.

If DELAY is blank or zero,

5.

TLOAD1 loads may be combined with TLOAD2 loads only by specification on a DLOAD
entry. That is, the SID on a TLOAD1 entry may not be the same as that on a TLOAD2
entry.

Altair Engineering

will be zero.

OptiStruct 13.0 Reference Guide 2115


Proprietary Information of Altair Engineering

6.

SID must be unique for all TLOAD1, TLOAD2, RLOAD1, and RLOAD2 entries.

7.

TLOAD2 entries cannot be used with Fourier analysis.

8.

The continuation entry is optional.

9.

When EXCITEID refers to an SPCD entry, the modal space will be augmented with
displacement vector(s) from linear static analysis with unit prescribed displacement at
each of the SPCD degrees-of-freedom. EXCITEID cannot reference the LOAD and
LOADADD bulk data entries.

10. This card is represented as a loadcollector in HyperMesh.

2116 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TSTEP
Bulk Data Entry
TSTEP Transient Time Step
Description
Defines time step intervals at which a solution will be generated and output in transient
analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

TSTEP

SID

N1

DT1

N01

W3,1

W4,1

N2

DT2

N02

W3,2

W4,2

(9)

(10)

-etc.-

Example

(1)

(2)

(3)

(4)

(5)

TSTEP

10

.001

0.01

Field

Contents

SID

Set identification number.

(6)

(7)

(8)

(9)

(10)

No default (Integer > 0)


N#

Number of time steps of value DT#.


No default (Integer > 1)

Altair Engineering

OptiStruct 13.0 Reference Guide 2117


Proprietary Information of Altair Engineering

Field

Contents

DT#

Time increment.
No default (Real > 0.0)

N0#

Skip factor for output. Every N0i-th step will be saved for output.
Default = 1 (Integer > 0)

W3,#

The frequency of interest in radians per unit time; used for the conversion of
overall structural damping into equivalent viscous damping. See comment 3.
Default = blank (Real > 0.0, or blank)

W4,#

The frequency of interest in radians per unit time; used for the conversion of
element structural damping into equivalent viscous damping. See comment 3.
Default = blank (Real > 0.0, or blank)

Comments
1.

TSTEP entries must be selected with the Subcase Iinformation command TSTEP = SID.

2.

Note that the entry permits changes in the size of the time step during the course of the
solution. Thus, in the example shown, there are 10 time steps of value .001, followed by
9 time steps of value .01. Also, in the case of this example, you have requested that the
output be recorded for t = 0.0, .005, .01, .02, .03, and so on.

3.

W3 and W4 define frequencies used in transient analyses to convert structural damping to


equivalent viscous damping. See the Reference Guide entries for PARAM,W3 and
PARAM,W4 for more details.

4.

Different values for W3 and W4 may be set for each set of time increments. If any of the
fields are left blank then the value is taken from the PARAM, W3 or PARAM, W4 definition.

5.

This card is represented as a loadcollector in HyperMesh.

2118 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TSTEPNL
Bulk Data Entry
TSTEPNL Parameters for Geometric Nonlinear Implicit Dynamic Analysis Control
Description
Defines parameters for geometric nonlinear implicit dynamic analysis strategy.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

TSTEPNL

ID

NDT

DT

KSTEP

C ONV

EPSU

EPSP

EPSW

MAXLS

LSTOL

Example

(1)

(2)

TSTEPNL

99

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

0.01

Field

Contents

ID

Each TSTEPNL bulk data card must have a unique ID.


No default (Integer > 0)

NDT

Number of implicit load sub-increments.


No default (Integer > 0)

DT

Initial time step.


No default (Real > 0)

KSTEP

Number of iterations before stiffness update. See comment 3.

Altair Engineering

OptiStruct 13.0 Reference Guide 2119


Proprietary Information of Altair Engineering

Field

Contents
Default = 6 for BCS solver
Default = 3 for PCG solver
(Integer > 0)

CONV

Flags to select implicit convergence criteria.


Default = UPW
(Any combination of U, P and W)

EPSU

Error tolerance for displacement (U) criterion.


Default = 1.0E-2
(Real > 0.0)

EPSP

Error tolerance for load (P) criterion.


Default = 1.0E-2
(Real > 0.0)

EPSW

Error tolerance for work (W) criterion.


Default = 1.0E-3
(Real > 0.0)

MAXLS

Maximum number of line searches allowed for each iteration.


Default = 20 (Integer > 0)

LSTOL

Line search tolerance.


Default = 1.0E-3 (Real > 0.0)

Comments
1.

The TSTEPNL bulk data entry is selected by the Subcase Information command TSTEPNL
= option. Each subcase for which nonlinear implicit dynamic analysis is desired requires a
TSTEPNL command.

2.

Additional control for geometric nonlinear implicit dynamic solution schemes (ANALYSIS =
IMPDYN) can be defined using TSTEPNX bulk data entry. Defaults will be used if TSTEPNX
is not present.

3.

The solution method for geometric nonlinear implicit dynamic analysis (ANALYSIS =
IMPDYN) is modified or Quasi-Newton. The frequency of stiffness matrix updates is
controlled by KSTEP. For highly nonlinear problems, it is recommended to reduce KSTEP

2120 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

for better performance. KSTEP = 1 means full Newton. The initial implicit time step is DT.
All subsequent time steps will be determined automatically. Termination time, TTERM, is
defined by a TTERM subcase entry or computed from TTERM = NDT*DT. TTERM takes
precedence.
4.

The time integration scheme for implicit transient is defined on TSTEPNX. The default
method is -HHT.

5.

For more information about geometric nonlinear analysis, refer to the Geometric Nonlinear
Analysis section.

6.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2121


Proprietary Information of Altair Engineering

TSTEPNX
Bulk Data Entry
TSTEPNX Optional Parameters for Geometric Nonlinear Implicit Dynamic Analysis Control
Description
Defines additional parameters for geometric nonlinear implicit dynamic analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

TSTEPNX

ID

TA0

DTA

DTTH

NPRINT

RFILE

SOLV

TSC TRL

DTMIN

DTMAX

LSMETH

RREFIF

DYNA

ALFA

BETA

GAMA

SMDISP

ITW

DTSC I

LDTN

DTSC D

LARC

(8)

(9)

(10)

NC YC LE

FIXTID/
TOUT

Example 1

(1)

(2)

TSTEPNL

99

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(5)

(6)

(7)

(8)

(9)

(10)

0.01

Example 2

(1)

(2)

TSTEPNL

99

0.01

TSTEPNX

99

0.1

NEWT

(3)

ARC

(4)

1.e-4

0.1

2122 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Example 3

(1)

(2)

TSTEPNL

99

(3)

99

NEWT

(5)

(6)

0.01

0.01

TSTEPNX

(4)

(7)

(8)

(9)

(10)

PW

0.01

0.1

ARC

NEWM

1.e-4

0.1

0.25

0.5

Field

Contents

ID

Identification number of an associated TSTEPNL entry.


No default (Integer > 0)

TA0

Start time for writing animation files.


Default = 0.0 (Real > 0)

DTA

Output time step for animation files. If zero, no output (See comment 3).
Default = DT (Real > 0)

DTTH

Output time step for time history files. If zero, no output (See comment
3).
Default = 0.1*DT (Real > 0)

NPRINT

Print every NPRINT iterations. If negative, to .out and standard output;


if positive, only to .out file.
Default = -1 (Integer)

RFILE

Cycle frequency to write restart file for nonlinear iteration.

Altair Engineering

OptiStruct 13.0 Reference Guide 2123


Proprietary Information of Altair Engineering

Field

Contents
Default = 5000 (Integer > 0)

SOLV

Geometric nonlinear implicit solution method.


NEWT Modified Newton.
BFGS BFGS quasi-Newton method.
Default = NEWT (Character = NEWT, or BFGS)

TSCTRL

Time step control.


ARC Arc-length is used to accelerate and control the convergence. The
time step is determined by displacement norm control (arc-length).
SIMP Simple time step control.
NONE No time step control. A warning will be issued. In the case of
divergence, the time step will be repeated with half the step size. The
run will be terminated according to DTMIN and NCYCLE.
Default = ARC (Character)

DTMIN

Minimum geometric nonlinear implicit time step. If DTMIN is reached,


simulation will be terminated (See comment 3).
Default = 1e-5*DT (Real > 0)

DTMAX

Maximum geometric nonlinear implicit time step from which time step is set
constant (See comment 3).
Default = 3*DT (Real > 0)

LSMETH

Line search method.


Default = ENERGY (Character = NONE, FORCE, ENERGY, or AUTO)

RREFIF

Special residual force computation with contact interfaces present.


Default = no special treatment (Integer = 0, , 5)
0
1
2
3
4

Aggressive (modified entirely by the out-of-balance value).


Average (modified each time with 200% maximum).
Light (modified each time with 20% maximum).
No change.
No change; except for the first contact.

2124 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
5

NCYCLE

Modified automatically (for imposed displacement only).

Maximum number of time steps. If reached, solution will be terminated.


NCYCLE = 0 means no limit.
Default = no limit (Integer > 0)

FIXTID

Identification number of a TABLEDi entry. The x values of the table define


fixed time points that the automatic time step control will adhere to.
(Integer > 0)

TOUT

The method to determine the fixed time point.


AUTO Fully automatic time step control.
NLOAD - The time points in all TABLEDi that are referenced by NLOAD1 in
one subcase.
Default = AUTO (AUTO or NLOAD)

DYNA

Implicit transient solution methods.


HHT -HHT method.
NEWM General Newmark method.
Default = HHT (Character = HHT or NEWM)

ALFA

Parameter in -HHT Method (DYNA = HHT).


Default = -0.05 (Real, -1/3 < ALFA < 0.0)

BETA

Parameter in general Newmark method (DYNA = NEWM).


Default = 0.25 (Real, -2 * BETA < GAMA < 0.5)

GAMA

Parameter in general Newmark method (DYNA = NEWM).


Default = 0.5 (Real, -2 * BETA < GAMA < 0.5)

SMDISP

Perform small displacement and rotation analysis instead of geometric


nonlinear analysis. PARAM, SMDISP, YES overwrites this definition.
OFF Geometric nonlinear analysis.

Altair Engineering

OptiStruct 13.0 Reference Guide 2125


Proprietary Information of Altair Engineering

Field

Contents
ON Small displacements and small rotations analysis.
Default = OFF (Character = ON, OFF)

ITW

If the solution of a time step converges within ITW iterations, the next
time step will be increased by a factor controlled by DTSCI.
Default = 6 for TSCTRL = ARC
Default = 2 for TSCTRL = SIMP
(Integer > 0)

DTSCI

Maximum scale factor for increasing the time step (TSCTRL = ARC). Scale
factor for TSCTRL = SIMP.
Default = 1.1 (Real > 0)

LDTN

Maximum number of iterations before resetting and decreasing the time


step by a factor of DTSCD.
Default = 20 for TSCTRL = ARC
Default = 15 for TSCTRL = SIMP
(Integer > 0)

DTSCD

Scale factor for decreasing the time step (TSCTRL = ARC, SIMP).
Default = 0.67 (Real > 0)

LARC

Input arc-length for TSCTRL = ARC.


Default = automatic computation (Real)

Comments
1.

The TSTEPNX bulk data entry is selected by the Subcase Information command TSTEP =
option. There must also be a TSTEPNL bulk data entry with the same ID. It is only used
in geometric nonlinear implicit dynamic analysis (ANALYSIS = IMPDYN); it is ignored in
other analyses.

2.

The solution method for geometric nonlinear implicit analysis is selected by SOLV. The
frequency of stiffness matrix updates is controlled by TSTEPNL, KSTEP. For highly
nonlinear problems, it is recommended to reduce KSTEP for better performance. KSTEP =
1 means full Newton.

3.

The initial time step DTINI = DT is defined by TSTEPNL.

2126 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

For more information about geometric nonlinear analysis, refer to the Geometric Nonlinear
Analysis section.

5.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2127


Proprietary Information of Altair Engineering

UNBALNC
Bulk Data Entry
UNBALNC Unbalanced Load (Rotor Dynamics)
Description
This entry defines the unbalanced rotating load during a rotor dynamic analysis in Frequency
Response solution sequences. The unbalanced load is specified in a cylindrical system where
the rotor rotation axis is the Z-axis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

UNBALNC

SID

MASS

GRID

X1

X2

X3

ROFFSET

THETA

ZOFFSET

FON

FOFF

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

UNBALNC

200

1.2

3103

1.0

0.0

0.0

0.3

45.0

0.1

110

Argument

Options

SID

<Integer > 0>

(8)

(9)

(10)

Description
setid

Set identification number.

No default

MASS

<Integer > 0/Real>

Defines the magnitude of unbalanced mass (see


comment 4).

(No default)

2128 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

GRID

<Integer>

Description
Grid Point identification number of node at which the
unbalanced load is applied.

No default

X1, X2, X3

<Real>

Components of a vector that are used to define a


cylindrical coordinate system centered at GRID. The
vector components are defined from GRID in the
displacement coordinate system of the grid point at
GRID (see comment 6).

No default

ROFFSET

<Integer > 0/Real> <Integer > 0>


Default = 1.0

<Real>

If an integer value (must be greater


than 0) is input, it references the
identification number of a TABLEDi
entry that specifies the offset values
as a function of frequency (see
comment 4).
This field defines the distance by
which the unbalanced mass is offset in
the X-Y plane perpendicular to the Z
direction (spin axis, Figure 1).
If a real number is input, the offset
value is considered constant.

THETA

<Real>
Default = 0.0

ZOFFSET

Angular position (in degrees) of the unbalanced mass in


the cylindrical coordinate system defined by X1, X2, and
X3.

<Integer > 0/Real> <Integer > 0>


Default = 0.0

<Real>

Altair Engineering

If an integer value (must be greater than


0) is input, it references the identification
number of a TABLEDi entry that specifies
the offset values as a function of
frequency (see comment 4).
This field defines the distance by which
the unbalanced mass is offset in the Z

OptiStruct 13.0 Reference Guide 2129


Proprietary Information of Altair Engineering

Argument

Options

Description
direction (spin axis, Figure 1).
If a real number is input, the offset value
is considered constant.

F ON

<Real > 0>

This field defines the starting frequency at which the


unbalanced load is applied (see comment 5).

Default = 0.0

F OFF

<Real > 0>

This field defines the stopping (final) frequency at which


the unbalanced load is applied (see comment 5).

Default = 999999.0
Comments
1.

Currently, models containing multiple UNBALNC bulk data entries with the same set
identification number (SID) are not supported. Each UNBALNC bulk data entry must have a
unique SID.

2.

For frequency response analysis, the UNBALNC bulk data entry is referenced by a DLOAD
Subcase Information entry.

3.

An unbalanced load on the rotating system is generated as a consequence of these three


factors:
Unbalanced mass of the system (rotor) about its axis of rotation (MASS field on the
UNBALNC entry).
The magnitude of separation between the rotating axis and the unbalanced mass
(ZOFFSET and ROFFSET fields on the UNBALNC entry).
The angular spin speed of the rotor (specific fields on the RGYRO and RSPINR bulk data
entries).

4.

ROFFSET field:
Each entry in the TABLEDi entry specifies the distance by which the unbalanced mass is
offset in the X-Y plane (perpendicular to the axis of rotation of the rotor).
ZOFFSET field:
Each entry in the TABLEDi entry specifies the distance by which the unbalanced mass is
offset in the Z direction (axis of rotation of the rotor).

2130 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

5.

The rotation of the unbalanced load occurs in the positive Z direction which is defined by
GRIDA and GRIDB on the RSPINR bulk data entry.

6.

The initial position of the unbalanced mass and the direction of its subsequent rotation
are defined with respect to a cylindrical coordinate system. Its angular position is
measured from the plane defined by both the Z-axis and the vector (X1, X2, and X3) with
THETA=0.0 being the direction of the vector (X1, X2, and X3) itself. The rotation of the
unbalanced load occurs in the positive Z direction.

Altair Engineering

OptiStruct 13.0 Reference Guide 2131


Proprietary Information of Altair Engineering

USET
Bulk Data Entry
USET Set of Degrees-of-Freedom for Residual Vector Calculation
Description
Defines a set of degrees-of-freedom.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

USET

SNAME

G1

C1

G2

C2

G3

C3

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

USET

U6

564

765

1456

Field

Contents

SNAME

Set name

(9)

(10)

(Character, only U6, ZEROU6 are allowed)


Gi

Grid or scalar point identification numbers.


No default (Integer > 0)

Ci

Component numbers.
(Integer zero or blank for scalar points, or up to 6 unique digits (0 <
integer < 6) may be placed in the field with no embedded blanks for
grid points. The components refer to the coordinate system
referenced by the grid points.)

2132 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

A maximum of 18 degrees-of-freedom can be defined on one USET entry.

2.

If SNAME=ZEROU6, then the degrees-of-freedom are omitted from the set.

3.

For normal modes analysis with the Lanczos eigensolver, the case control command
RESVEC=YES must be used to create residual vectors based on the USET DOF . If the
AMSES or AMLS eigensolvers are used, the residual vectors will always be created. The
residual vectors are calculated using the unit load method.

4.

For modal frequency response and modal transient analysis, the USET residual vectors are
always calculated if the AMSES and AMLS eigensolvers are used, and are not calculated if
the Lanczos eigensolver is used.

5.

The residual vectors are then exported together with the eigenvectors to the H3D,
PUNCH, and OUTPUT2 files. If stress output is requested, the stress state for each mode
is output to the H3D, PUNCH, and OUTPUT files.

6.

If SNAME is not U6 or ZEROU6, USET will be ignored.

7.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank
when the grid reference is a scalar point (SPOINT), and that the component be > 1 when
the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is
allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point
(SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank;
interpreting all of these as 0 for scalar points and as 1 for structural grids. When the
component is greater than 1, the grid reference must always be a structural grid (GRID).

8.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2133


Proprietary Information of Altair Engineering

USET1
Bulk Data Entry
USET1 Set of Degrees-of-Freedom for Residual Vector Calculation, Alternate Form
Description
Defines a set of degrees-of-freedom.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

USET1

SNAME

G1

G2

G3

G4

G5

G6

G7

G8

G9

-etc.-

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

USET1

U6

123

34

88

12

19

1234

65

(10)

Alternate Format and Example


(1)

(2)

(3)

(4)

(5)

(6)

USET1

SNAME

G1

THRU

G2

USET1

U6

123456

88

THRU

207

Field

Contents

SNAME

Set name

(7)

(8)

(9)

(10)

(Character, only U6, ZEROU6 are allowed)

2134 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

Component number.
(Integer zero or blank for scalar points, or up to 6 unique digits (0 <
integer < 6) may be placed in the field with no embedded blanks for
grid points. The components refer to the coordinate system
referenced by the grid points.)

Gi

Grid or scalar point identification numbers.


(Integer > 0, for THRU option, G1 < G2)

Comments
1.

If the alternate format is used, all points in the sequence G1 through G2 are not required
to exist, but there must be at least one boundary degree-of-freedom for the model or a
fatal error will result. Any grids implied in the THRU that do not exist will collectively
produce a warning message, but will otherwise be ignored.

2.

If SNAME=ZEROU6, then the degrees-of-freedom are omitted from the set.

3.

For normal modes analysis with the Lanczos eigensolver, the case control command
RESVEC=YES must be used to create residual vectors based on the USET1 DOF. If the
AMSES or AMLS eigensolvers are used, the residual vectors will always be created. The
residual vectors are calculated using the unit load method.

4.

For modal frequency response and modal transient analysis, the USET1 residual vectors
are always calculated if the AMSES and AMLS eigensolvers are used, and are never
calculated if the Lanczos eigensolver is used.

5.

USET1 is applied to normal modes analysis subcases that have the case control
RESVEC=YES specified. In such cases, residual vectors are calculated using the unit load
method. The residual vectors are then exported together with the eigenvectors to the
H3D, PUNCH, and OUTPUT2 files. If stress output is requested, the stress state for each
mode is output to the H3D, PUNCH, and OUTPUT files.

6.

If SNAME is not U6 or ZEROU6, USET1 will be ignored.

7.

When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or
MIXED, it is allowed that when grid lists are provided for a given component, that the grid
references be either scalar points (SPOINT) or structural grid points (GRID) when the
component is 0, 1 or blank; interpreting all of these as 0 for scalar points and as 1 for
structural grids. When SPSYNTAX is set to STRICT it is required for grid/component pairs
(G#/C#) that the component be 0 or blank when the grid references are to scalar points
(SPOINT), and that the component be > 1 when the grid references are to structural grid
points (GRID). When the component is greater than 1, the grid references must always
be a structural grid (GRID).

8.

This card is represented as a constraint load in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2135


Proprietary Information of Altair Engineering

XDAMP
Bulk Data Entry
XDAMP Raleigh Damping for Geometric Nonlinear Dynamic Analysis
Description
Defines values for Raleigh damping for geometric nonlinear dynamic analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

XDAMP

DID

GSID

ALFA

BETA

(7)

(8)

(9)

(10)

Example

(1)

(2)

(3)

(4)

(5)

XDAMP

100

34

3.0

1.0

(6)

Field

Contents

DID

Unique damping identification number.

(7)

(8)

(9)

(10)

(Integer > 0)
GSID

Grid set identification number. Damping is applied to the grid points


in this set.
Default = all grids in the model (blank or Integer > 0)

ALFA

Factor for the stiffness matrix contribution.


(Real > 0)

BETA

Factor for the mass matrix contribution.


(Real > 0)

2136 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

Rayleigh damping is applied to all geometric nonlinear dynamic analysis subcases, implicit
and explicit. It is ignored in all other subcases.

2.

In implicit dynamic analysis damping is applied to all grid points and GSID is ignored.
Multiple XDAMP is not allowed in implicit dynamic analysis.

3.

XDAMP and PARAM W3/G are mutually exclusive.

4.

Grid sets in all XDAMP statements must contain unique sets of grid points.

5.

The viscous damping matrix B is calculated from the mass matrix M and stiffness matrix K
using:
B = ALFA * M + BETA * K

6.

This card is represented as an interface in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2137


Proprietary Information of Altair Engineering

XHISADD
Bulk Data Entry
XHISADD Time History Output Combination for Geometric Nonlinear Analysis
Description
Defines a time history output set as a union of time history outputs defined via XHIST
entries.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

XHISADD

SID

S1

S2

S3

S4

S5

S6

S7

S8

S9

etc.

(10)

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

XHISADD

101

Field

Contents

SID

Set identification number.

(8)

(9)

(10)

(Integer > 0)
Sj

Set identification numbers of time history output defined via XHIST


entries.
(Integer > 0)

Comments
1.

Multipoint constraint sets must be selected with the Subcase Information command
XHIST=SID.

2138 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

2.

The Sj must be unique and may not be the identification number of a rigid wall set defined
by another XHISADD entry.

3.

XHISADD entries take precedence over XHIST entries. If both have the same SID, only
the XHISADD entry will be used.

4.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2139


Proprietary Information of Altair Engineering

XHIST
Bulk Data Entry
XHIST Time History Output Request for Geometric Nonlinear Analysis
Description
Defines the time history output request for geometric nonlinear analysis.
Format
(1)

(2)

(3)

XHIST

SID

(4)

(5)

(6)

(7)

(8)

(9)

(10)

LABEL

FILE

TYPE

C ID

DTTHM

DATA

VAR1

VAR2

VAR3

VAR4

VAR5

VAR6

VAR7

VAR8

...

ID1

ID2

ID3

ID4

ID5

ID6

ID7

ID8

...

ENTRY

Example

(1)

(2)

XHIST

100

(3)

(4)

(5)

AY

(6)

(7)

(8)

(9)

(10)

GRID

DATA

DEF

AX

ENTRY

345

6687

2140 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

SID

Set identification number.


(Integer > 0)

LABEL

(Character or blank)

FILE

Creation of different time history files runnameTnnx(n:0-1,x:blank or a-i).


(Characters A, B, C, and I, or blank)

TYPE

Entity type. See table 1.


(Character according to table)

CID

Frame coordinate system identification.


(Integer > 0)

DTTHM

Output time step for time history files. Once it is specified, it will
overwrite DTTH on NLPARMX, TSTEPNX and XSTEP to control the output
time step of history file specified by FILE in this card.

DATA

DATA flag indicating that data labels follow. If no DATA is specified, the
default is VAR1 = DEF.

VARi

Output data label. See table 1.


(Character)

ENTRY

ENTRY flag indicating that a list of identifiers is following.

IDi

Entry identifier for TYPE. See table 1.


(Integer > 0)

Comments
1.

XHIST sets must be selected with the Subcase Information command XHIST = SID or by
XHISADD. It can only be selected in geometric nonlinear analysis subcases which are
defined by an ANALYSIS = NLGEOM, IMPDYN or EXPDYN subcase entry.

2.

Table 1 below gives the definitions of TYPE, VARi, and IDi. The notation DEF (DX, DY, DZ,
VX, VY, VZ) means that if DEF is selected, all six values following in parenthesis are
written at once. However, instead of requesting DEF each value can be requested
individually. Details on the output requests can be found in Table 2.

Altair Engineering

OptiStruct 13.0 Reference Guide 2141


Proprietary Information of Altair Engineering

3.

A property cannot be in several time history groups. In this case, the only variables
output in time history are the variables declared in the last option which refers to the
property.

4.

It is not possible to have the same grid point several times in the same GRID group.
OptiStruct provides an error message in such cases.

5.

If an output coordinate system GRID, CD is specified: coordinates, displacement, linear


and angular velocities, linear and angular accelerations of the grid are projected to that
system.

6.

If a reference frame is specified: local coordinates, relative displacement, relative linear


and angular velocities, relative linear and angular accelerations of the node with respect
to the frame are output.

7.

Global results are always written.

8.

The OFF element status information works as follows:


OFF = 0 Element deleted.
OFF = 1 Element active.
OFF = 2 Element active using small strain.
OFF = -1 Element is sleeping (turned rigid).

Table 1: Output Requests


TYPE

VARi

IDi

GRID

DEF (DX, DY, DZ, VX, VY, VZ), D (DX, DY, DZ),
V (VX, VY, VZ), A (AX, AY, AZ), VR (VRX, VRY,
VRZ) AR (ARX, ARY, ARZ), XYZ (X, Y, Z),
REACX, REACY, REACZ, REACXX, REACYY,
REACZZ

Grid ID

PROP

DEF (IE, KE, XMOM, YMOM, ZMOM, MASS, HE),


XCG, YCG, ZCG, XXMOM, YYMOM, ZZMOM, IXX,
IYY, IZZ, IXY, IYZ, IZX, RIE, KERB, RKERB, RKE

Property ID

SHELL

DEF (F1, F2, F12, M1, M2, M12, IEM, IEB, EMIN,
EMAX, OFF), STRESS (F1, F2, F12, Q1, Q2, M1,
M2, M12), STRAIN (E1, E2, E12, SH1, SH2, K1,
K2, K12), PLAS (EMIN, EMAX)

Element ID

SOLID

DEF (SX , SY, SZ, SXY, SYZ, SXZ, IE, DENS,


PLAS, TEMP, OFF), STRESS (SX, SY, SZ, SXY,
SYZ, SXZ), LOCSTRS (LSX, LSY, LSZ, LSXY,
LSYZ, LSXZ), BULK, VOL, DAM1, DAM2, DAM3,
DAM4, DAM5, DAMA, EPSXX, EPSYY, EPSZZ,
EPSXY, EPSXZ, EPSYZ

Element ID

2142 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

TYPE

VARi

IDi

RWALL

DEF (FNX, FNY, FNZ, FTX, FTY, FTZ), FN (FNX,


FNY, FNZ), FT (FTX, FTY, FTZ)

Load set ID of
RWALL

CONTCT

DEF (FNX, FNY, FNZ, FTX, FTY, FTZ), FN (FNX,


FNY, FNZ), FT (FTX, FTY, FTZ), M (MX, MY,
MZ)

Contact ID

SECT

DEF (FNX, FNY, FNZ, FTX, FTY, FTZ, M1, M2,


Load set ID of
M3), FN (FNX, FNY, FNZ), FT (FTX, FTY, FTZ),
XSECT
M (MX, MY, MZ), GLOBAL (FNX, FNY, FNZ, FTX,
FTY, FTZ, MX, MY, MZ), LOCAL (F1, F2, F3, M1,
M2, M3), CENTER (CX, CY, CZ)

SPRING,
BUSH

DEF (FX, FY, FZ, MX, MY, MZ, LX, LY, LZ, RX,
RY, RZ, IE, OFF)

Element ID

BEAM, BAR

DEF (F1, F2, M2, M3, IE, OFF), F3, M1

Element ID

ROD

DEF(F, M, IE)

Element ID

Table 2: Output Request Descriptions


Type

Output Data Label

Description and Remarks

Global

IE

Internal energy.
Global internal energy includes all
material internal energy and global
spring internal energy, but not spring
rotational internal energy.

KE

Kinetic energy.

RKE

Rotational kinetic energy.

CE

Contact energy.

HE

Hourglass energy.

SIE

Spring internal energy.

EFW

External forces work.

TE

Energy sum IE + KE.

Altair Engineering

OptiStruct 13.0 Reference Guide 2143


Proprietary Information of Altair Engineering

Type

Output Data Label

Description and Remarks

RTE

Total rotational energy IE + KE + RKE.

TTE

Total energy sum IE + KE + RKE + CE +


HE.

DTE

Delta energy TTE - EFW.

XMOM, YMOM, ZMOM

Momentum.

DT

Time step.

TER
DTE_REL

GRID

PROP

VX, VY, VZ

Velocities.

X, Y, Z

Coordinates.

DX, DY, DZ

Displacement components.

VX, VY, VZ

Velocity components.

AX, AY, AY

Acceleration components.

VRX, VRY, VRZ

Angular velocity components.

ARX, ARY, ARZ

Angular acceleration components.

REACX, REACY, REACZ

Reaction force components

REACXX, REACYY, REACZZ

Reaction moment components

IE

Internal energy.

KE

Kinetic energy.

XMOM, YMOM, ZMOM

Momentum components.

HE

Hourglass energy.

XCG, YCG, ZCG

Center of gravity.

XXMOM, YYMOM, ZZMOM

Rotational momentum components.

2144 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type

SHELL

Output Data Label

Description and Remarks

IXX, IYY, IZZ, IXY, IYZ,


IZX

Inertia matrix components.

RIE

Shear internal energy.

KERB, RKERB

Translational and rotational rigid body


energy.

RKE

Rotational kinetic energy.

F1, F2, F12

Stress in direction 1, 2, 12.

Q1, Q2

Mean stress in direction 13, 23.

M1, M2, M12

Moments per unit length per thickness


square in direction 1, 2, 12.

IEM, IEB

Internal membrane and bending energy.

EMIN, EMAX

Minimum, maximum equivalent plastic


strain.

OFF

Element status.
See comment 8.

SOLID

THIC

Thickness.

E1, E2, E12

Stress in direction 1, 2, 12.

SH1, SH2

Shear strain in direction 1, 2.

K1, K2, K12

Curvature in direction 1, 2, 12.

SX , SY, SZ, SXY, SYZ,


SXZ

Stress tensor components.

LSX, LSY, LSZ, LSXY,


LSYZ, LSXZ

Local stress tensor components.

IE

Internal energy.

DENS

Density.

BULK

Bulk viscosity.

Altair Engineering

Only ISOLID = 1, 2, 12

OptiStruct 13.0 Reference Guide 2145


Proprietary Information of Altair Engineering

Type

Output Data Label

Description and Remarks

VOL

Volume.

PLAS

Plastic strain.
Only MATX02.

TEMP

Temperature.

OFF

Element status.
See comment 8.

CONTCT

FNX, FNY, FNZ, FTX, FTY,


FTZ

Normal and tangential force


components.

MX, MY, MZ

Moment components.

RWALL

FNX, FNY, FNZ, FTX, FTY,


FTZ

Normal and tangential force


components.

SECT

FNX, FNY, FNZ, FTX, FTY,


FTZ

Normal and tangential force


components.

MX, MY, MZ

Moment components.

F1, F2, F3, M1, M2, M3

Forces and moments in section


coordinates.

CX, CY, CZ

Center of the section.

FX, FY, FZ, MX, MY, MZ

Forces and moment components.

LX, LY, LZ

Elongation.

RX, RY, RZ

Rotation.

IE

Internal energy.

OFF

Element status.

F1, F2, F3, M1, M2, M3

Forces and moments in element


coordinates

IE

Internal energy

OFF

Element status

SPRING, BUSH

BEAM, BAR

2146 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type

Output Data Label

Description and Remarks

ROD

Axial force

Torsional moment

IE

Internal energy

Altair Engineering

OptiStruct 13.0 Reference Guide 2147


Proprietary Information of Altair Engineering

XSHLPRM
Bulk Data Entry
XSHLPRM Default Definition for Shell Element Properties for Geometric Nonlinear Analysis
Description
Defines default shell element parameters for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

XSHLPRM

ISHELL

ISH3N

ISMSTR

ITHIC K

IPLAS

NIP

IDRIL

(10)

Example

(1)

(2)

XSHLPRM

14

(3)

(4)

(5)

(6)

(7)

NEWT

Field

Contents

ISHELL

Flag for 4-node shell element formulation.

(8)

(9)

(10)

Default = 24 (Integer)
1 - Q4, visco-elastic hourglass modes orthogonal to deformation and
rigid modes (Belytschko).
2 - Q4, visco-elastic hourglass without orthogonality (Hallquist).
3 - Q4, elastic-plastic hourglass with orthogonality.
4 - Q4 with improved type 1 formulation (orthogonalization for
warped elements).
12 - QBAT or DKT18 shell formulation.
24 - QEPH shell formulation.
ISH3N

Flag for 3-node shell element formulation.

2148 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
Default = 2 (Integer)
1 - Standard triangle (C0).
2 - Standard triangle (C0) with modification for large rotation.
30 - DKT18.
31 - DKT_S3.

ISMSTR

Flag for shell small strain formulation.


Default = 2 (Integer)
1 - Small strain from time =0
(new formulation compatible with all other formulation flags).
2 - Full geometric non-linearity with optional small strain formulation
activation by time step.
3 - Old small strain formulation (only compatible with ISHELL =2).
4 - Full geometric non-linearity (Time step limit has no effect).

ITHICK

Flag for shell resultant stresses calculation.


Default = VAR (CONST or VAR)
CONST - Thickness is constant.
VAR - Thickness change is taken into account.

IPLAS

Flag for shell plane stress plasticity (MATX2, MATX27, and MATX36
only).
Default = NEWT (RAD or NEWT)
RAD - Radial return.
NEWT - Iterative projection with 3 Newton iterations.

NIP

Number of integration points through the thickness. NIP = 0 defines


global integration.
Default = 5 (Integer 0 < N < 10)

IDRIL

Flag for drilling degree of freedom stiffness.

Altair Engineering

OptiStruct 13.0 Reference Guide 2149


Proprietary Information of Altair Engineering

Field

Contents
If NLGEOM or IMPDYN subcase exists, default = 1,
Otherwise, default = 0 (Integer)
0 = No
1 = Yes

Comments
1.

XSHLPRM defines default settings for solid properties that can be overwritten by PSHELLX.

2.

XSHLPRM is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

Q4: Original 4 node OptiStruct shell with hourglass perturbation stabilization.


QEPH: Formulation with physical hourglass stabilization for general use.
QBAT: Modified BATOZ Q4 24 shell with 4 Gauss integration points and reduced
integration for in-plane shear. No hourglass control is needed for this shell.
DKT18: BATOZ DKT18 thin shell with 3 Hammer integration points.

4.

ISHELL = 2 is incompatible with one integration point for shell element.

5.

If the small strain option (ISMSTR) is set to 1 or 3, the strain and stress are engineering
strain and stress; otherwise they are true strain and stress.

6.

Global integration (NIP = 0) is only compatible with MAT1, MATX2, and MATX36.

7.

For MAT1, membrane only behavior happens if NIP = 1. Otherwise, NIP is ignored and
global integration (NIP = 0) is used.

8.

For ITHICK = VAR, it is recommended to use IPLAS = NEWT.

9.

For MATX2, the default value for IPLAS and global integration (NIP=0) is IPLAS = RAD.

10. For MATX36, the default value for IPLAS and global integration (NIP=0) is IPLAS = NEWT.
11. This card is represented as a control card in HyperMesh.

2150 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

XSOLPRM
Bulk Data Entry
XSOLPRM Default SOLID Properties for Geometric Nonlinear Analysis
Description
Defines default SOLID properties for geometric nonlinear analysis.
Format
(1)

(2)

(3)

(4)

(5)

XSOLPRM

ISOLID

ISMSTR

IFRAME

NIP

(6)

(7)

(8)

(9)

(10)

Example

(1)

(2)

XSOLPRM

24

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

222

Field

Contents

ISOLID

Flag for solid elements formulation.


Default = 1 for explicit analysis and 14 for implicit analysis (Integer).
1 - Standard 8-node solid element, 1 integration point. Viscous
hourglass formulation with orthogonal and rigid deformation modes
compensation (Belytschko).
2 - Standard 8-node solid element, 1 integration point. Viscous
hourglass formulation without orthogonality (Hallquist).
12 - Standard 8-node solid, full integration (no hourglass).
14 - HA8 locking-free 8-node solid element, co-rotational, full
integration, variable number of Gauss points.
16 - Quadratic 20-node solid, full integration, variable number of
Gauss points.
17 - H8C compatible solid full integration formulation.

Altair Engineering

OptiStruct 13.0 Reference Guide 2151


Proprietary Information of Altair Engineering

Field

Contents
24 - HEPH 8-node solid element. Co-rotational, under-integrated.
(1 Gauss point) with physical stabilization.

ISMSTR

Flag for small strain formulation (ISOLID = 1, 2, 14, and 24 only).


Default = 4 (Integer)
1 - Small strain from time=0.
2 - Full geometric non-linearity with small strain formulation
activation by time step.
3 - Simplified small strain formulation from time=0 (non-objective
formulation).
4 - Full geometric non-linearity. Time step limit has no effect.
10 - Lagrange type total strain.

IFRAME

Flag for co-rotational element formulation (ISOLID = 1, 2, 12, and


17 only).
Default = OFF (ON or OFF)

NIP

Number of integration points (ISOLID = 14, 16 only).


Default = 222 (Integer = ijk):
2 < i,j,k < 9

for ISOLID =14

2 < i,k < 3, 2 < j < 9

for ISOLID =16

where:
i = Number of integration points in local x direction.
j = Number of integration points in local y direction.
k = Number of integration points in local z direction.
Comments
1.

XSOLPRM defines default settings for solid properties that can be overwritten by PSOLIDX.

2.

XSOLPRM is only applied in geometric nonlinear analysis subcases which are defined by
ANALYSIS = NLGEOM, IMPDYN, or EXPDYN. It is ignored for all other subcases.

3.

The ISOLID flag is not used with CTETRA elements. For these, elements with four and
ten nodes the number of integration points is fixed at one and four, respectively.

2152 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

For fully integrated solids (SOLID =12), the deviatoric behavior is computed using 8 Gauss
points; bulk behavior is under-integrated to avoid element locking. It is currently
compatible with material MAT1, MATS1, MATX33, and MATX36.

5.

With the small strain option (ISMSTR), strain and stress is engineering strain and stress.
Otherwise, it is true strain and stress.

6.

In time history and animation files, the stress tensor is written in the co-rotational frame.

7.

Fully integrated elements (ISOLID =12) only uses full geometric non-linearity (corresponds
to ISMSTR = 4). Time step limit has no effect.

8.

ISMSTR = 10 is only compatible with materials using total strain formulation (MATX42).

9.

The time step control XSTEP, TYPEi = SOLID, TSCi = CST only works on elements with
ISMSTR = 2.

10. Co-rotational formulation: For ISOLID = 1, 2, 12 and IFRAME = ON, the stress tensor is
computed in a co-rotational coordinate system. This formulation is more accurate if large
rotations are involved. It comes at the expense of higher computation cost. It is
recommended in case of elastic or visco-elastic problems with important shear
deformations. The co-rotational formulation is compatible with 8 node solids.
11. HA8 (ISOLID = 14) elements: this element uses a locking-free general solid formulation,
co-rotational. The number of Gauss points is defined by NIP flag: for example, combined
with NIP = 222 gives an 8 Gauss integration point element, similar to ISOLID = 12. The
HA8 formulation is compatible with all material laws.
12. HEPH (ISOLID = 24) elements: This element uses an hourglass formulation similar to QEPH
shell elements.
13. The hourglass formulation is viscous for ISOLID = 0, 1, and 2.
14. This card is represented as a control card in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2153


Proprietary Information of Altair Engineering

XSTEP
Bulk Data Entry
XSTEP Parameters for Explicit Analysis Control
Description
Defines explicit analysis control.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

XSTEP

SID

TA0

DTA

DTTH

NPRINT

RFILE

NITER

NPAMS

DTSC A

DTMIN

TSTYP

TAC T

TYPE1

TSC 1

DT1

DTM1

ESID1

AMST1

TYPE2

TSC 2

DT2

DTM2

ESID2

AMST2

-etc.-

Example

(1)

(2)

XSTEP

(3)

0.9

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DETAIL

GRID

C ST

0.9

0.1e-6

Field

Contents

SID

Set identification number.


(Integer > 0)

2154 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

TA0

Start time for writing animation files.


Default = 0.0 (Real > 0)

DTA

Output time step for animation files. If zero, no output (See


comment 3).
Default = 0.01*TTERMS (Real > 0)

DTTH

Output time step for time history files. If zero, no output (See
comment 3).
Default = 0.001*TTERMS (Real > 0)

NPRINT

Print every NPRINT iteration. If negative, to .out and standard


output; if positive, only to .out file.
Default = -1000 (Integer)

RFILE

Cycle frequency to write restart file for nonlinear iteration.


Default = 5000 (Integer > 0)

NITER

Maximum number of iterations in conjugate gradient.


Only valid when TSTYP = GRID and TACT = AMS.
Default = 1000 (Integer > 0)

NPAMS

Frequency (number of cycles) for writing additional output about


the number of iterations before convergence in the conjugate
gradient.
No default (Integer > 0)

DTSCA

Default scale factor on explicit time step for all elements.


Default = 0.9 (Real > 0)

DTMIN

Default minimum explicit time step.


Default = 0.0 (Real > 0)

TSTYP

Type of time step control (See comment 2).

Altair Engineering

OptiStruct 13.0 Reference Guide 2155


Proprietary Information of Altair Engineering

Field

Contents

ELEM

Elemental time step.

GRID

Nodal time step.

CONTACT

Contact interface time step

DETAIL

From definition in continuation lines.

Default = GRID (Character = GRID, ELEM, CONTACT or DETAIL)


TACT

Action if minimum time step is reached (For TSTYP = GRID, ELEM,


CONTACT, See comment 3).
DEF

Default (TSTYP = GRID, CONTACT Do nothing, ELEM


(Shells) = DEL, ELEM (Solids) = STOP).

DEL

Delete (TSTYP = ELEM and CONTACT only).

STOP

Stop run.

CST

Standard mass scaling. Continue with constant time step.

AMS

Advanced mass scaling. Continue with constant time step


(TSTYP = GRID and CONTACT only).

Default = DEF (Character = DEF, STOP, DEL, CST, or AMS)


TYPEi

Entity type selection (See comment 4).


No default (Character = GRID, CONTACT, SHELL, and SOLID)

TSCi

Time step control method (See comment 4).


STOP

Stop after reaching DTMi. A restart file will be written.


This option is the default for brick and quad elements.

DEL

Element deletion. Elements reaching DTMi are removed.


This option is the default for shell elements. For TYPEi =
CONTACT, the impacted grid that fixes the time step will
be removed from the interface.

CST

Constant time step after reaching DTMi.


For TYPEi = SHELL, SOLID (except 8 integration points
hexas) the formulation switches to small strain for each

2156 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents

element that reaches the DTMi.


For TYPEi = GRID, CONTACT, the mass of the grid that
reaches DTMi is increased. You should check the evolution
of the mass of the model.
AMS

Advanced mass scaling. Constant time step after reaching


DTMi. Advanced Mass Scaling does not modify the global
mass so that the global momentum of the related nodes is
conserved. More accurate than TSCi = CST (TYPEi = GRID
and CONTACT only).

SET

Forces are reduced to keep constant time step (TYPEi =


GRID only).

Default = according to table (blank or Character = STOP, DEL, CST,


AMS, SET)
DTi

Time step scale factor for entity type (See comment 4).
Default = 0.9 (Real > 0.0)

DTMi

Minimum time step for entity type.


Default = 0.0 (Real > 0.0)

ESIDi
AMS).
No default (blank, Integer > 0)
AMSTi

Tolerance for advanced mass scaling convergence (Only for TYPEi =


AMS).
Default = 10-4 (REAL > 0.0)

Comments
1.

The XSTEP bulk data entry is selected by the Subcase Information command XSTEP =
option. It is only used in explicit analysis (ANALYSIS = EXPDYN); it is ignored in other
analyses.

2.

Any number of continuation lines can be used.

3.

Time step control for explicit analysis

Altair Engineering

OptiStruct 13.0 Reference Guide 2157


Proprietary Information of Altair Engineering

TSTYP

Elements

Default

Options

Do nothing

AMS, CST, STOP

Shells

DEL

CST, STOP

Solids

STOP

CST, DEL

GRID
ELEM

With TSTYP = GRID, the nodal time step is used. With this option, the computation of
each cycle is slightly more expensive, but the time step can be higher, mainly for nonoptimized meshes and therefore the overall runtime shorter.
For TSTYP = GRID, TACT = CST, the mass of the grid that reaches DTMIN1 is increased.
You should check the evolution of the mass of the model.
For TSTYP = ELEM, TACT = CST, the element formulation switches to small strain for
each element that reaches the DTMIN1.
4.

Overview of default settings and options for TYPEi:


Do Nothing

STOP

DEL

CST

AMS

SET

SHELL

N/A

Optional

Default

Optional

N/A

N/A

SOLID

N/A

Default

Optional

Optional

N/A

N/A

CONTACT

Default

Optional

Optional

Optional

Optional

N/A

GRID

Default

Optional

N/A

Optional

Optional

Optional

With TYPEi = GRID, the nodal time step is used. With this option, the computation of
each cycle is slightly more expensive, but the time step can be higher, mainly for nonoptimized meshes and therefore the overall runtime shorter.
With TYPEi = GRID and TSCi = CST, DTi = 0.67 is recommended.
With TYPEi = CONTACT and TSCi = DEL, the impacted node which fixes the time step is
removed from the interface.
TYPEi = SOLID and TSCi = CST is only active for solid elements with the flag ISMSTR = 2
set on PSOLIDX. This option is not available for 8 integration points.
5.

For more information about geometric nonlinear analysis, refer to the Geometric Nonlinear
Analysis section.

6.

TSTYP = NODA and TACT = AMS can activate elementary time step for Advanced Mass
Scaling, as well as TYPEi = NODA and TSCi = AMS.

7.

NITER and NPAMS are only valid for Advanced Mass Scaling (AMS). If more NITER
iterations have been performed before convergence of the conjugate gradient, the
computation stops and error out. If NPAMS is specified, at each NPAMS cycle an
additional output is provided including: the number of iterations before convergence of

2158 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

the conjugate gradient at this cycle, the final residual norm and the force vector norm.
8.

This card is represented as a loadcollector in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2159


Proprietary Information of Altair Engineering

Element Quality Check


In order to prevent analyses from being carried out on badly discretized models, an element
quality check is incorporated into the pre-processing phase. The element quality check is
controlled jointly by the CHECKEL parameter (see PARAM, CHECKEL) and the ELEMQUAL bulk
data entry.
Three types of element quality checks are performed:
1.

Validity check of maximum allowable limits a bound based on mathematical limitations.


Violation will cause singular or ill-conditioned element matrices. Examples are: a reentrant angle (equal to or greater than 180 degrees) in quadrilateral element/surface, 0
collapse in tetra.

2.

Quality check of error limits whether an element is in the acceptable range.

3.

Quality check of warning limits whether an element is in the recommended range.


Violation may cause poor result quality, but will not stop the solution process.

With the CHECKEL parameter, type 2 and 3 checks may be controlled and the ELEMQUAL bulk
data entry may be used to set the error and warning limits. However, the "validity" check,
type 1, is always performed even when the value of PARAM, CHECKEL is NO.
A check for collapsed element nodes is performed for all elements. All other property checks
are performed after this collapsed node check, and will be skipped if collapsed nodes are
found. If the element quality check is activated, the checks for each element are performed
according to the following precedence: (1) validity check, (2) quality check for error limits,
and (3) quality check for warning limits. Violation of any check will skip the subsequent
check(s).
The warp angle check on CQUAD4 elements is relaxed for topography optimization. This
relaxation prevents premature error termination of the optimization due to element quality
concerns. However, be aware that the resulting mesh from a topography optimization may fail
the CQUAD4 warp angle check when reanalyzed.
The checks performed and the default bound values for each element type are outlined in the
following topics:
CGASK6 Element Checks and Default Bound Values
CGASK8 Element Checks and Default Bound Values
CGASK12 Element Checks and Default Bound Values
CGASK16 Element Checks and Default Bound Values
CTRIA3 Element Checks and Default Bound Values
CTRIA6 Element Checks and Default Bound Values
CQUAD4 Element Checks and Default Bound Values
CQUAD8 Element Checks and Default Bound Values
CTAXI / CTRIAX6 Element Checks and Default Bound Values
CTETRA Element Checks and Default Bound Values
CPENTA Element Checks and Default Bound Values
CHEXA Element Checks and Default Bound Values

2160 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CPYRA Element Checks and Default Bound Values

Altair Engineering

OptiStruct 13.0 Reference Guide 2161


Proprietary Information of Altair Engineering

CGASK6 Element Checks and Default Bound Values


CGASK6 Element Check and Default Bounds
The element check and default bounds of the CGASK6 element are identical as those of the
first-order (6-noded) CPENTA element.

2162 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CGASK8 Element Checks and Default Bound Values


CGASK8 Element Check and Default Bounds
The element check and default bounds of the CGASK8 element are identical as those of the
first-order (8-noded) CHEXA element.

Altair Engineering

OptiStruct 13.0 Reference Guide 2163


Proprietary Information of Altair Engineering

CGASK12 Element Checks and Default Bound Values


CGASK12 Element Check and Default Bounds
The element check and default bounds of the CGASK12 element are identical as those of the
second-order (15-noded) CPENTA element. Notice that CGASK12 has six 3-node edges of
which Hoe Normal Offset and Hoe Tangent Offset are checked.

2164 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CGASK16 Element Checks and Default Bound Values


CGASK16 Element Check and Default Bounds
The element check and default bounds of the CGASK16 element are identical as those of the
second-order (20-noded) CHEXA element. Notice that CGASK16 has 8 3-node edges of which
Hoe Normal Offset and Hoe Tangent Offset are checked.

Altair Engineering

OptiStruct 13.0 Reference Guide 2165


Proprietary Information of Altair Engineering

CTRIA3 Element Checks and Default Bound Values


CTRIA3 Element Check
The following qualities of the CTRIA3 element are checked:
Aspect Ratio
The aspect ratio of a CTRIA3 element is defined as the ratio of the maximum side
length to the minimum side length.
Skew Angle
The skew angle of a CTRIA3 element is the difference between 90 degrees and the
minimum of three angles: a1, a2 and a3. These angles are defined, for the CTRIA3
element, as the smallest of the angles created when a line drawn from a node to the
midpoint of the opposing side intersects a line connecting the midpoints of the
adjacent two sides. The skew angle has a range from 0 degrees for a perfect triangle
to 90 degrees for a collapsed triangle.
SKEW = 90 - MIN(a1,a2,a2 )

Vertex Angle
For each vertex, the angle is measured between its two adjacent edges. The minimum
and maximum values of the three nodes are reported for the element.
CTRIA3 Default Bounds
Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

50.0

500.0

1.0E5

Skew Angle

75.0

85.0

90.0

Vertex Angle

15.0

165.0

3.0

177.0

0.0

180.0

Information

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2166 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Altair Engineering

OptiStruct 13.0 Reference Guide 2167


Proprietary Information of Altair Engineering

CQUAD4 Element Checks and Default Bound Values


CQUAD4 Element Check
The following qualities are checked for CQUAD4 elements:
Vertex Angle
For each vertex, the angle is measured between its two adjacent edges. The minimum
and maximum values of the four nodes are reported for the element.
Aspect Ratio
The aspect ratio of a CQUAD4 element is the length of its longest side, divided by the
length of its shortest side.
Skew Angle
The skew angle in a CQUAD4 element is calculated by finding the minimum angle
between two lines joining opposite mid-sides of the element. Ninety degrees minus the
minimum angle found is reported.
Warp Angle
The warpage of a CQUAD4 element is calculated by splitting the quad into two trias
and finding the angle between the two planes which the trias form. The quad is then
split again, this time using the opposite corners and forming the second set of trias.
The angle between the two planes, which the trias form, is then found. The maximum
angle found between the planes is the warp angle of the element.

CQUAD4 Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

100.0

1000.0

1.0E5

Skew Angle

60.0

75.0

90.0

Warp Angle*

30.0

60.0

180.0

Vertex Angle

15.0

165.0

3.0

177.0

0.0

180.0

Information

*Warp angle limits are relaxed to 140/160/179 in topography optimization problems.


The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2168 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CQUAD8 Element Checks and Default Bound Values


CQUAD8 Element Check
The following qualities are checked for CQUAD8 elements:
Vertex Angle
This quality is calculated using only the corner nodes. For each vertex, the angle is
measured between its two adjacent edges. The minimum and maximum values of the
four nodes are reported for the element.
Aspect Ratio
This quality is calculated using only the corner nodes. The aspect ratio of a CQUAD8
element is the length of its longest side, divided by the length of its shortest side.
Skew Angle
This quality is calculated using only the corner nodes. The skew angle in a CQUAD8
element is calculated by finding the minimum angle between two lines joining opposite
mid-sides of the element. Ninety degrees minus the minimum angle found is reported.
Warp Angle
This quality is calculated using only the corner nodes. The warpage of a CQUAD8
element is calculated by splitting the quad into two trias and finding the angle between
the two planes which the trias form. The quad is then split again, this time using the
opposite corners and forming the second set of trias. The angle between the two
planes, which the trias form, is then found. The maximum angle found between the
planes is the warp angle of the element.
Hoe Normal Offset
The hoe normal offset is the maximum of its edges normal offset values. See the
definition of hoe normal offset of 3-node edge.
Hoe Tangent Offset
The hoe tangent offset is the maximum of its edges tangent offset values. See the
definition of hoe tangent offset of 3-node edge.

CQUAD8 Default Bounds


Default values for
warning message

Information

Default values for


error message

Default values for


validity check

Lower Limit Upper Limit Lower Limit Upper Limit Lower Limit Upper Limit
Aspect Ratio

100.0

1000.0

1.0E5

Skew Angle

60.0

75.0

90.0

Altair Engineering

OptiStruct 13.0 Reference Guide 2169


Proprietary Information of Altair Engineering

Information

Default values for


warning message

Default values for


error message

Default values for


validity check

Lower Limit Upper Limit Lower Limit Upper Limit Lower Limit Upper Limit
Warp Angle

90.0

175.0

180.0

Vertex Angle

15.0

165.0

3.0

177.0

0.0

180.0

Hoe Normal Offset

0.30

0.60

1.0E5

Hoe Tangent
Offset

0.20

0.24

0.25

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2170 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTAXI / CTRIAX6 Element Checks and Default Bound


Values
3-node CTAXI / CTRIA6 Element Check and Default Bounds
The element check and default bounds of the 3-node CTAXI or CTRIAX6 element are identical
as those of the CTRIA3 element.

6-node CTAXI / CTRIA6 Element Check and Default Bounds


The element check and default bounds of the 6-node CTAXI or CTRIAX6 element are identical
as those of the CTRIA3 element.

Altair Engineering

OptiStruct 13.0 Reference Guide 2171


Proprietary Information of Altair Engineering

CTRIA6 Element Checks and Default Bound Values


CTRIA6 Element Check
The following qualities of the CTRIA6 element are checked:
Aspect Ratio
This quality is calculated using only the corner nodes. It is defined as the ratio of the
maximum side length to the minimum side length.
Skew Angle
This quality is calculated using only the corner nodes. It is the difference between 90
degrees and the minimum of three angles: a1, a2 and a3. These angles are defined, for
the CTRIA6 element, as the smallest of the angles created when a line drawn from a
node to the midpoint of the opposing side intersects a line connecting the midpoints of
the adjacent two sides. The skew angle has a range from 0 degrees for a perfect
triangle to 90 degrees for a collapsed triangle.
Vertex Angle
This quality is calculated using only the corner nodes. For each vertex, the angle is
measured between its two adjacent edges. The minimum and maximum values of the
three nodes are reported for the element.
Hoe Normal Offset
The hoe normal offset is the maximum of its edges normal offset values. See the
definition of hoe normal offset of 3-node edge.
Hoe Tangent Offset
The hoe tangent offset is the maximum of its edges tangent offset values. See the
definition of hoe tangent offset of 3-node edge.

CTRIA6 Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

50.0

500.0

1.0E5

Skew Angle

75.0

85.0

90.0

Vertex Angle

15.0

165.0

3.0

177.0

0.0

180.0

Hoe Normal
Offset

0.30

0.60

1.0E5

Information

2172 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Default values for


warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

0.20

0.24

0.25

Information

Hoe Tangent
Offset

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

Altair Engineering

OptiStruct 13.0 Reference Guide 2173


Proprietary Information of Altair Engineering

Hoe Tangent Offset of 3-node Edge


The hoe tangent offset of a 3-node edge is defined as the ratio of the distance between the
real and ideal mid-side node and the distance between the corner nodes of the edge. If the
mid-side node does not lie on the line connecting the corner nodes (that is the edge has a
non-zero normal offset), then its projection on the line is used in the calculation.
HTEi

Hoe tangent offset of edge i

di / li

2174 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Hoe Normal Offset of 3-node Edge


The hoe normal offset of a 3-node edge is defined as the ratio between the mid-side nodes
normal offset distance (distance between the mid-side node and the line connecting the two
corner nodes of the edge) and the distance between the two corner nodes.
HNEi

Hoe normal offset of edge i

hi / li

Altair Engineering

OptiStruct 13.0 Reference Guide 2175


Proprietary Information of Altair Engineering

CTETRA Element Checks and Default Bound Values


CTETRA 1st-order (4-noded) Element Checks
The following qualities of the CTETRA 1st-order element are checked:
Aspect Ratio
The aspect ratio of a CTETRA 1st-order element is defined as the maximum of the aspect
ratio of its four triangular faces. Each face is treated as a CTRIA3 element.
Face Skew Angle
The face skew angle of a CTETRA 1st-order element is defined as the maximum of the
skew angles of its four triangular faces. Each face is treated as a CTRIA3 element.
Vertex Angle
The same vertex angle check is performed for all of the faces, and each is treated as a
triangular (CTRIA3) or quadrilateral (CQUAD4) element. The minimum and maximum values
reported for the element.
Collapse
The collapse of a CTETRA 1st-order element is defined as the minimum of four values,
each calculated as the ratio between the distance from a vertex to its opposing face, and
the square root of the area of the opposing face.
collapse = MIN (hi / sqrt(Ai))

i = 1,2,3,4

The reported value is normalized by 1.2408, which gives the equilateral tetra a collapse
value of 1. As the tetra collapses, the collapse value approaches 0.
Edge Angle
An edge angle is the absolute value of the angle between two faces sharing a common
edge subtracted from 90 degrees. The edge angle (EA) of a CTETRA 1st-order element is
defined as the maximum of its six edge angles.
EA = MAX | 90 - ANGLE(Nki, Nli)

i = 1, ... 6

Where, Nki and Nli are the normal vectors of faces k and l that have a common edge i.

2176 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CTETRA 2nd-order (10-noded) Element Checks


The following qualities of the CTETRA 2nd-order element are checked:
Aspect Ratio
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CTETRA 1st-order element.
Face Skew Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CTETRA 1st-order element.
Vertex Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CTETRA 1st-order element.
Collapse
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CTETRA 1st-order element.
Edge Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CTETRA 1st-order element.
Hoe Normal Offset
The hoe normal and tangent offsets of the CTETRA 2nd-order element are defined as the
maximum of the hoe normal and tangent offsets of its 6 edges, respectively. See the
definition of hoe normal offset of 3-node edge.
Hoe Tangent Offset
The hoe normal and tangent offsets of the CTETRA 2nd-order element are defined as the
maximum of the hoe normal and tangent offsets of its 6 edges, respectively. See
definition of hoe tangent offset of 3-node edge.

Altair Engineering

OptiStruct 13.0 Reference Guide 2177


Proprietary Information of Altair Engineering

CTETRA Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

100.0

1000.0

1.0E5

Face Skew Angle

75.0

85.0

90.0

C ollapse

0.001

100.0

0.0

100.0

0.0

1000.0

Edge Angle

75.0

87.0

90.0

Hoe Normal Offset

0.30

0.60

1.0E5

Hoe Tangent Offset

0.20

0.25

0.50

Information

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2178 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CPENTA Element Checks and Default Bound Values


CPENTA 1st-order (6-noded) Element Checks
The following qualities of the CPENTA 1st-order element are checked:
Aspect Ratio
The aspect ratio of a CPENTA 1st-order element is defined as the maximum of the aspect
ratios of its three quadrilateral faces and two triangular faces. Each quadrilateral face is
treated as a CQUAD4 element and each triangular face as a CTRIA3 element.
Face Skew Angle
The skew angle of a CPENTA 1st-order element is defined as the maximum skew angle
among its three quadrilateral faces and two triangular faces. Each quadrilateral face is
treated as a CQUAD4 element and each triangular face as a CTRIA3 element.
Vertex Angle
The same vertex angle check is performed for all of the faces, and each is treated as a
triangular (CTRIA3) or quadrilateral (CQUAD4) element. The minimum and maximum values
reported for the element.
Face Warpage
The face warpage of a CPENTA 1st-order element is defined as the maximum warpage
among the three quadrilateral faces, each treated as a CQUAD4 element.
Twist Angle
The twist angle is defined as the rotation of one triangular face with respect to the
opposite triangular face. The rotation is computed as follows: first construct a reference
plane perpendicular to the line connecting the centroids of the two triangular faces. The
three edges of each triangular are then projected to this reference plane. The maximum
angle between the corresponding edges of the two projected triangles is reported as the
twist angle of the CPENTA 1st-order element.
Edge Angle
The edge angle is the absolute value of the angle between two faces sharing a common
edge, subtracted from 90 degrees. For warped quadrilateral faces, the projected planes
defined by the plane vectors are used to compute the face normals (see definition of
reference plane for quadrilateral element or face), which are used in the angle calculation.
The edge angle of a CPENTA 1st-order is defined as the maximum edge angles in the
element.

CPENTA 2nd-order (15-noded) Element Checks


The following qualities of the CPENTA 2nd-order element are checked:
Aspect Ratio
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.

Altair Engineering

OptiStruct 13.0 Reference Guide 2179


Proprietary Information of Altair Engineering

Face Skew Angle


This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.
Vertex Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.
Face Warpage
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.
Twist Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.
Edge Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPENTA 1st-order element.
Hoe Normal Offset
The hoe normal offset is the maximum of its edges normal offset values. See the definition
of hoe normal offset of 3-node edge.
Hoe Tangent Offset
The hoe tangent offset is the maximum of its edges tangent offset values. See the
definition of hoe tangent offset of 3-node edge.

CPENTA Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

100.0

1000.0

1.0E5

Skew Angle

60.0

75.0

90.0

Face Warp Angle

30.0

60.0

180.0

Twist Angle

30.0

75.0

90.0

Edge Angle

75.0

87.0

90.0

Information

2180 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Default values for


warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Hoe Normal Offset

0.30

0.60

1.0E5

Hoe Tangent
Offset

0.20

0.25

0.5

Information

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

Altair Engineering

OptiStruct 13.0 Reference Guide 2181


Proprietary Information of Altair Engineering

Reference Plane for Quadrilateral Element or Face


In order to measure the distortion of the quadrilateral face of a solid element, a unique
reference plane is defined by two auxiliary plane vectors. The plane vectors are calculated
as:
PL1 = (V3 + V2 ) - (V1 + V4 )
PL2 = (V3 + V4 ) - (V1 + V2 )
where, V1, V2, V3, and V4 are the vectors that connect the four corner nodes with the
centroid of the quadrilateral. These two plane vectors and the centroid are then used to
construct the reference plane. These vectors of a non-warping quadrilateral face are shown
below:

2182 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CHEXA Element Checks and Default Bound Values


CHEXA 1st-order (8-noded) Element Checks
The following qualities of the CHEXA 1st-order element are checked:
Aspect Ratio
The aspect ratio of a CHEXA 1st-order element is defined as the maximum aspect ratio
among its six faces; each treated as a CQUAD4 element.
Face Skew Angle
The face skew angle of a CHEXA 1st-order element is defined as the maximum skew angle
among its six faces; each treated as a CQUAD4 element.
Vertex Angle
The same vertex angle check is performed for all of the faces, and each is treated as a
quadrilateral (CQUAD4) element. The minimum and maximum values reported for the
element.
Face Warpage
The face warpage of a CHEXA 1st-order element is defined as the maximum warpage
among its six faces; each treated as a CQUAD4 element.
Twist Angle
The twist angle of a CHEXA 1st-order element is defined as the maximum rotation of one
face with respect to its opposite face. The calculation is done as follows:
For each face, define two diagonal vectors as:
D1 = 0.25 * (PL1 + PL2)
D2 = 0.25 * (PL1 + PL2)
where, PL1 and PL2 are the place vectors of the face treated as CQUAD4. See the
definition of reference plane for quadrilateral element or face. The diagonal vectors for a
planar parallelogram can be show below:

Then, for each pair of opposing faces, a reference plane that is perpendicular to the axis
connecting the centroids of the faces is constructed. The diagonal vectors D1 and D2 of
each of the two opposite faces are projected onto this reference plane. The angles
between the projected
and the projected
are computed as t 1 and t 2. The
maximum of t 1 and t 2 is defined as the relative rotation between these two opposite faces
(TAF). Finally, the twist angle (TA) of a CHEXA 1st-order is calculated as the maximum
relative rotation of its three pairs of opposing faces.

Altair Engineering

OptiStruct 13.0 Reference Guide 2183


Proprietary Information of Altair Engineering

Edge Angle
An edge angle is the absolute value of the angle between two faces sharing a common
edge, subtracted from 90 degrees. For warped faces, the projected planes are used to
compute the face normals used for the angle calculation. The edge angle of a CHEXA 1storder is defined as the maximum edge angle in the element.

CHEXA 1st-order Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Information
Lower Limit Upper Limit Lower Limit Upper Limit Lower Limit Upper Limit
Aspect Ratio

100.0

1000.0

2184 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

1.0E5

Altair Engineering

Default values for


warning message

Default values for


error message

Default values for


validity check

Information
Lower Limit Upper Limit Lower Limit Upper Limit Lower Limit Upper Limit
Face Skew Angle

60.0

75.0

90.0

Face Warp Angle

30.0

60.0

180.0

Twist Angle

30.0

90.0

180.0

Edge Angle

60.0

85.0

90.0

CHEXA 2nd-order (20-noded) Element Checks


The following qualities of the CHEXA 2nd-order element are checked:
Aspect Ratio
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Face Skew Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Vertex Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Face Warpage
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Twist Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Edge Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CHEXA 1st-order element.
Hoe Normal Offset
The hoe normal offset is the maximum of its edges normal offset values. See the definition
of hoe normal offset of 3-node edge.

Altair Engineering

OptiStruct 13.0 Reference Guide 2185


Proprietary Information of Altair Engineering

Hoe Tangent Offset


The hoe tangent offset is the maximum of its edges tangent offset values. See the
definition of hoe tangent offset of 3-node edge.

CHEXA 2nd-order Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

100.0

1000.0

1.0E5

Face Skew Angle

60.0

75.0

90.0

Face Warp Angle

30.0

60.0

180.0

Twist Angle

30.0

75.0

180.0

Edge Angle

60.0

89.0

90.0

Hoe Normal
Offset

0.30

0.60

1.0E5

Hoe Tangent
Offset

0.20

0.25

0.50

Information

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2186 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CPYRA Element Checks and Default Bound Values


CPYRA 1st-order (5-noded) Element Checks
The following qualities of the CPYRA 1st-order element are checked:
Aspect Ratio
The aspect ratio of a CPYRA 1st-order element is defined as the maximum of the aspect
ratios of its four triangular faces and the quadrilateral base face. Each triangular face is
treated as a CTRIA3 element and the quadrilateral face as a CQUAD4 element.
Face Skew Angle
The face skew angle of a CPYRA 1st-order element is defined as the maximum of the skew
angles of its four triangular faces and the quadrilateral base face. Each triangular face is
treated as a CTRIA3 element and the quadrilateral face as a CQUAD4 element.
Vertex Angle
The same vertex angle check is performed for all of the faces, and each is treated as a
triangular (CTRIA3) or quadrilateral (CQUAD4) element. The minimum and maximum values
reported for the element.
Face Warpage
The face skew angle of a CPYRA 1st-order element is defined as the warpage of its
quadrilateral base face, which is treated as a CQUAD4 element.

CPYRA 2nd-order (13-noded) Element Checks


The following qualities of the CPYRA 2nd-order element are checked:
Aspect Ratio
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPYRA 1st-order element.
Face Skew Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPYRA 1st-order element.
Vertex Angle
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPYRA 1st-order element.
Face Warpage
This quality is calculated using only the corner nodes. Its definition is the same as that
used for the CPYRA 1st-order element.

Altair Engineering

OptiStruct 13.0 Reference Guide 2187


Proprietary Information of Altair Engineering

Hoe Normal Offset


The hoe normal offset is the maximum of its edges normal offset values. See the definition
of hoe normal offset of 3-node edge.
Hoe Tangent Offset
The hoe tangent offset is the maximum of its edges tangent offset values. See the
definition of hoe tangent offset of 3-node edge.

CPYRA Default Bounds


Default values for
warning message

Default values for


error message

Default values for


validity check

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Lower
Limit

Upper
Limit

Aspect Ratio

100.0

1000.0

1.0E5

Skew Angle

60.0

75.0

90.0

Face Warp Angle

30.0

60.0

180.0

Hoe Normal Offset

0.30

0.60

1.0E5

Hoe Tangent Offset

0.20

0.25

0.5

Information

The values used for warning and error checks may be adjusted by the ELEMQUAL bulk data
entry, but validity checks are hard-coded.

2188 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Material Property Check


In order to prevent analyses from being carried out on models with poor material definitions, a
material property check is incorporated into the pre-processing phase. The material property
check is controlled by the CHECKMAT parameter (see the PARAM input format).
There are several levels of requirements that material data needs to satisfy:
1.

Symmetry requirements - These are assured by the input formats.

2.

Mathematical requirements - These have to be satisfied so that the stiffness matrix can
be formulated at all, and are usually not very strict. For example, to avoid division by
zero, MAT1 in 3D must have n-1 and n0.5. Composite homogenization adds additional
mathematical requirements. Failure to meet these criteria will always result in an error
termination.

3.

Stability requirements - By default, "semi-stability" combined with "not-all-zeros" stability


based on the following definitions is required:
Full stability - This means that the material is stable; when pulled it stretches rather
than shrinks, etc. For example, E>0 assures stability for a rod. In a mathematical
sense, stability assures that the stiffness matrix (with proper support) will be SemiPositive Definite (SPD).
Semi-stability - This is a slight extension of stability to include borderline cases such as
allowing E=0. It guarantees that the stiffness matrix (with proper support) will be
Semi-Positive Semi-Definite (SPSD). However, this can lead to infinite or very large
compliances.
Not all zeros - This is an additional requirement that at least one deformation mode of
the material is active (non-zero stiffness). This avoids element stiffness matrices that
are identically zero. However, It does not prevent infinite or very large compliances.
An error termination will occur if a material has negative stiffness.
A warning is produced if any individual mode of deformation has zero stiffness.
An error termination will occur if all modes of deformation have zero stiffness.

4.

Consistency requirements - This is a requirement that user provided data be internally


consistent. For example, specifying E, G and Nu for isotropic material may lead to
inconsistent data.

5.

Practical material requirements - These are requirements that correspond to typical


practical materials. For example, while stability requirements allow for negative Poisson's
ratio, the natural materials usually have positive n (although some composites and nanomaterials with negative n exist).

You may choose to perform only those checks that are necessary to avoid crashes in the
element routines (that is the Mathematical Requirement checks). This is facilitated through
the specification of PARAM,CHECKMAT,NO in the bulk data section of the input deck.
The checks performed for MAT1, MAT2, MAT3, MAT8, and MAT9 are outlined in the following
topics:
Material Property Checks for MAT1
Material Property Checks for MAT2

Altair Engineering

OptiStruct 13.0 Reference Guide 2189


Proprietary Information of Altair Engineering

Material Property Checks for MAT3


Material Property Checks for MAT8
Material Property Checks for MAT9

2190 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Material Property Checks for MAT1


In addition to the property requirements, there are usage and recalculation rules for MAT1
data.

Usage Rules for MAT1 Data


Element Type

ROD, BEAM,
BAR

Used for bending and


tension.

Used for torsion.

Unused.

QUAD, TRIA

Used in combination with


n for bending and
membrane.

Used for transverse


shear.

Used in combination with


E for bending and
membrane.

SOLID

Used in combination with


n.

Unused.

Used in combination with


n.

Recalculation Rules for MAT1


In cases when not all material parameters are given for MAT1, here are the recalculation rules
for the remaining parameters. Note that in cases of two prescribed parameters, this is
obvious; while in cases of a single prescribed parameter, you are making an assumption as to
which one is assumed to be zero.
Given
E

given
given

Mean
n

given

as given

G = E / 2(1 + n)

as given

as given

as given

n = E/2G - 1

E = 2G(1 + n)

as given

as given

as given

0.0

0.0

0.0

as given

0.0

given
given

given

given
given
given

Altair Engineering

not allowed

OptiStruct 13.0 Reference Guide 2191


Proprietary Information of Altair Engineering

Material Requirements for MAT1


The property requirements on MAT1 vary depending on whether it is used for 1D, 2D, or 3D
elements. The details are provided in the table below.
Material
Requirements

MAT1 - 1D

MAT1 - 2D

MAT1 - 3D

Mathematical

n = -1 results in error
termination.

n = -1 or n = 1
results in error
termination.

Semi-stability

E < 0 or G < 0 results


in error termination.

E < 0, G < 0, n < -1 E < 0, n < -1, or n >


> or -n > 0.5 results 0.5 results in error
in error termination. termination.

PARAM,CHECKMAT,NO
will disable this error.

PARAM,CHECKMAT,N
O will disable this
error.

PARAM,CHECKMAT,N
O will disable this
error.

If both E = 0 and G =
0, an error termination
occurs.

If both E = 0 and G
= 0, an error
termination occurs.

E < 0 results in error


termination.

If either E = 0 or G =
0, a warning is given.

If either E = 0 or G =
0, a warning is
given.

A warning is provided

A warning is provided A warning is

n < -1 or n > 0.5


results in a warning
(however, this is
unused in 1D).
Not all zeros

Consistency

n = -1 or n = 0.5
results in error
termination.

n).
Mathematical for
composites

/ 2(1 + n).

After
homogenization, if
either E = 0 or G =
0, an error
termination occurs.

2192 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Material Property Checks for MAT2


MAT2 only applied to 2D elements.
Material Requirements

MAT2

Mathematical

none

Semi-stability

If any eigenvalues of [G] < 0, an error termination will occur.


PARAM,CHECKMAT,NO will disable this error.

Not all zeros

If all eigenvalues of [G] = 0, an error termination will occur.


If any eigenvalue of [G] = 0, a warning is provided.

Consistency

none

Mathematical for
composites

After homogenization, if Det[G] = 0, an error termination will


occur.

Altair Engineering

OptiStruct 13.0 Reference Guide 2193


Proprietary Information of Altair Engineering

Material Property Checks for MAT3


MAT3 only applies to axisymmetric elements.
Material Requirements
Mathematical

MAT3
If EX = 0, ETH = 0, EZ = 0 or
NUXTH * NUTHX + NUTHZ * NUZTH + NUZX * NUXZ + 2 *
NUXTH * NUTHZ * NUZX = 1,
an error termination will occur (See comment 1).

Semi-stability

If EX < 0, ETH < 0, EZ < 0 or GZX < 0, an error termination


will occur.
PARAM,CHECKMAT,NO will disable this error.

Not all zeros

If GZX = 0, a warning is provided.

Consistency

none

Comments
1.

By substitution of

into
NUXTH * NUTHX + NUTHZ * NUZTH + NUZX * NUXZ + 2 * NUXTH * NUTHZ * NUZX = 1,
it can be expressed in terms of

2194 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Material Property Checks for MAT8


MAT8 only applies to 2D elements.
Material Requirements
Mathematical

MAT8
If n1 2 *n2 1 = 1, an error termination will occur (See comment
1).

Semi-stability

E1 < 0, E2 < 0, G1 2 < 0, G1 ,Z < 0, or G2 ,Z < 0 will result in an


error termination.
PARAM,CHECKMAT,NO will disable this error.

Not all zeros

If E1 = 0, E2 = 0 , and G1 2 = 0, an error termination will


occur.
If E1 = 0, E2 = 0 , or G1 2 = 0, a warning is provided.

Consistency

E1 *n2 1 = E2 *n1 2 is assured as only n12 is input.

Mathematical for
composites

After homogenization, if Det[G] = 0, an error termination will


occur.

Comments
1.

By substitution of E1*n21 = E2*n12 into n12*n21 = 1, it can be expressed in terms of


n12*n12*E2/E1 = 1.

Altair Engineering

OptiStruct 13.0 Reference Guide 2195


Proprietary Information of Altair Engineering

Material Property Checks for MAT9


MAT9 only applies to 3D elements.
Material Requirements

MAT9

Mathematical

none

Semi-stability

If any eigenvalues of [G] < 0, an error termination will occur.


PARAM,CHECKMAT,NO will disable this error.

Not all zeros

If all eigenvalues of [G] = 0, an error termination will occur.


If any eigenvalue of [G] = 0, a warning is provided.

Consistency

none

2196 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Output Data
Descriptions for individual output files can be accessed by selecting from the links for each
entry, listed below in groups according to type and alphabetically on the Files Created by
OptiStruct page.
The filenames listed on this page contain only the tail part of the name. For most files, the
full filename is controlled by the OUTFILE command (ASSIGN,OUTFILE), and in the absence of
OUTFILE, they use the root of input filename. Unless otherwise noted for a specific file type
(.#.eigv), all output files have the same root and are located in the same folder. The only
exception is <BODY_NAME>.h3d; these files may not have a common root in the filename.
HyperMesh

OptiStruct

.amls_singularity.cmf file

.#.asens file

.HM.comp.cmf file

.#.eigv file

.HM.conn.cmf file

.#.sens file

.HM.elcheck.cmf file

.#.grid file

.HM.elcheck.###.cmf file

.#.sh file

.HM.ent.cmf file

.cstr file

.HM.gapstat.cmf file

.dens file

.res file

.disp file
.dvgrid file

HyperView/HyperGraph

.echo file

.#.h3d file

.force file

.h3d file

.fsthick file

.hgdata file

.gpf file

_des.h3d file

.grid file

_freq.mvw file

.hist file

_gauge.h3d file

.interface file

_hist.mvw file

.load file

_mass.mvw file

.mass file

_modal.#.mvw file

.mpcf file

_modal.mvw file

.out file

_rand.mvw file

.pret file

_topol.h3d file

.prop file

_tran.mvw file

.rand file

_s#.h3d file

.seplot file

_sens.#.mvw file

.sh file

Altair Engineering

OptiStruct 13.0 Reference Guide 2197


Proprietary Information of Altair Engineering

_freq.#.mvw file

.spcd file

_mass.#.mvw file

.spcf file
.stat file

Nastran

.strn file

.k.op2 file

.strs file

.m.op2 file

_err.grid file

.op2 file

_s#_a.frf file

.pch file

_s#_a.mbd file

.peak file

_s#_a.trn file
_s#_d.frf file

OSSmooth

_s#_d.mbd file

.oss file

_s#_d.trn file
_s#_v.frf file

Multi-body Dynamics

_s#_v.mbd file

_mbd.h3d file

_s#_v.trn file

_mbd.log file

.#.#.fat file

_mbd.mrf file

.#.mass file

_mbd.mvw file

.desvar file

_mbd.xml file

.pcomp file

<BODY_NAME>.h3d file

_s#_a.#.frf file

.mnf file

_s#_d.#.frf file
_s#_v.#.frf file
_shuffling.#.fem file
_sizing.#.fem file

Patran

Alternative Patran

.#.#.#.dis file

.#.#.dis.# file

.#.#.dis file

.#.dis.# file

.#.#.els file

.#.els.# file

.#.dis file

.dis.# file

.#.els file

.els.# file

HTML
Microsoft Excel

2198 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.html file
_frames.html file

.#.slk file
_gso.slk file

_menu.html file

Altair Engineering

OptiStruct 13.0 Reference Guide 2199


Proprietary Information of Altair Engineering

List of Files Created by OptiStruct (Alphabetical)


The filenames listed on this page contain only the tail part of the name. For most files, the
full filename is controlled by the OUTFILE command (ASSIGN,OUTFILE), and in the absence of
OUTFILE, they use the root of input filename. Unless otherwise noted for a specific file type
(.#.eigv), all output files have the same root and are located in the same folder. The only
exception is <BODY_NAME>.h3d; these files may not have a common root in the filename.
.#.#.#.dis file
.#.#.dis file
.#.#.dis.# file
.#.#.els file
.#.#.fat file
.#.asens file
.#.dis file
.#.dis.# file
.#.eigv file
.#.els file
.#.els.# file
.#.grid file
.#.h3d file
.#.mass file
.#.sens file
.#.sh file
.#.slk file
.amls_singularity.cmf file
.cntf file
.contgap.fem file
.cstr file
.dens file
.desvar file
.dis.# file
.disp file
.dvgrid file
.echo file
.els.# file
.force file
.fsthick file
.gpf file
.grid file

2200 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.h3d file
.hgdata file
.hist file
.HM.comp.cmf file
.HM.conn.cmf file
.HM.elcheck.cmf file
.HM.elcheck.###.cmf file
.HM.ent.cmf file
.HM.gapstat.cmf file
.html file
.interface file
.k.op2 file
.load file
.m.op2 file
.mass file
.mnf file
.mpcf file
.op2 file
.oss file
.out file
.pch file
.pcomp file
.peak file
.pret file
.prop file
.rand file
.res file
.seplot file
.sh file
.spcd file
.spcf file
.stat file
.strn file
.strs file
_des.h3d file
_err.grid file
_frames.html file
_freq.#.mvw file

Altair Engineering

OptiStruct 13.0 Reference Guide 2201


Proprietary Information of Altair Engineering

_freq.mvw file
_gauge.h3d file
_gso.slk file
_hist.mvw file
_mass.#.mvw file
_mass.mvw file
_mbd.h3d file
_mbd.log file
_mbd.mrf file
_mbd.mvw file
_mbd.xml file
_menu.html file
_modal.#.mvw file
_modal.mvw file
_rand.mvw file
_s#.h3d file
_s#_a.#.frf file
_s#_a.frf file
_s#_a.mbd file
_s#_a.trn file
_s#_d.#.frf file
_s#_d.frf file
_s#_d.mbd file
_s#_d.trn file
_s#_v.#.frf file
_s#_v.frf file
_s#_v.mbd file
_s#_v.trn file
_sens.#.mvw file
_shuffling.#.fem file
_sizing.#.fem file
_topol.h3d file
_tran.mvw file
<BODY_NAME>.h3d file

2202 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.#.#.dis file
The .#.#.#.dis file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the PATRAN format is chosen and normal modes analyses are
performed. (See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Eigenvector

Eigenvector results from normal modes analyses. Output is


controlled by the I/O Option DISPLACEMENT.

Comments
1.

One such file is created for each calculated mode at each iteration where the I/O Option
RESULTS requests analytical results to be output.

2.

The first # in the file name is the iteration number.

3.

The second # in the file name is the user-defined Subcase ID.

4.

The third # in the file name is the mode number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2203


Proprietary Information of Altair Engineering

.#.#.dis file
The .#.#.dis file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the PATRAN format is chosen and linear static analysis is performed.
(See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Displacement

Displacement results from linear static analysis. Output is


controlled by the I/O Option DISPLACEMENT.

Comments
1.

One such file is created for each subcase at each iteration where the I/O Option RESULTS
requests analytical results to be output.

2.

The first # in the file name is the iteration number.

3.

The second # in the file name is the user-defined Subcase ID.

2204 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.#.dis.# file
The .#.#.dis.# file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the APATRAN format is chosen and normal modes analyses are
performed. (See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Eigenvector

Eigenvector results from normal modes analyses. Output is controlled


by the I/O Option DISPLACEMENT.

Comments
1.

One such file is created for each calculated mode at each iteration where the I/O Option
RESULTS requests analytical results to be output.

2.

The first # in the file name is the user-defined Subcase ID.

3.

The second # in the file name is the mode number.

4.

The third # in the file name is the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2205


Proprietary Information of Altair Engineering

.#.#.els file
The .#.#.els file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the PATRAN format is chosen and linear static analysis is performed.
(See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Stress

Stress results from linear static analysis. Output is controlled by the I/O
Option STRESS (or ELSTRESS).

Comments
1.

One such file is created for each subcase at each iteration where the I/O Option RESULTS
requests analytical results to be output.

2.

The first # in the file name is the iteration number.

3.

The second # in the file name is the user-defined Subcase ID.

2206 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.#.fat file
The .#.#.fat file is an ASCII format result file.
File Creation
This file is created for fatigue analysis and optimization.
File Contents
This file contains the average fatigue life/damage, top five damaged elements, and the
detailed damage information (contribution from each static loadcase).
Comments
1.

The first # in the file name is the iteration number.

2.

The second # in the file name is the user-defined fatigue subcase ID.

3.

If a fatigue optimization is performed, this file is created for each fatigue subcase at the
first and last iterations.

Altair Engineering

OptiStruct 13.0 Reference Guide 2207


Proprietary Information of Altair Engineering

.#.asens file
The .#.asens file is an OptiStruct ASCII format results file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O option OUTPUT.
File Contents
The file contains sensitivity information for all responses with respect to topology design
variables (density) at a given iteration (denoted by the # in the file name).
File Format
The sensitivities are listed in a single column and are grouped by response. A blank line
separates each response grouping.
Comments
1.

The # in the file name is the iteration number.

2208 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.dis file
The .#.dis file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the PATRAN format is chosen and shape or topography design
variables are present. (See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Shape

Shape results from topography or shape optimizations. Output is


controlled by the I/O Option DENSRES.

Comments
1.

One such file is created for each iteration where the I/O Option DENSRES requests
topography or shape results to be output.

2.

The # in the file name is the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2209


Proprietary Information of Altair Engineering

.#.dis.# file
The .#.dis.# file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the APATRAN format is chosen and linear static analysis is performed.
(See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Displacement

Displacement results from linear static analysis. Output is controlled


by the I/O Option DISPLACEMENT.

Comments
1.

One such file is created for each subcase at each iteration where the I/O Option RESULTS
requests analytical results to be output.

2.

The first # in the file name is the user-defined Subcase ID.

3.

The second # in the file name is the iteration number.

2210 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.eigv file
The _#.eigv file is an OptiStruct binary data file.
File Creation
This file is created by the subcase information entry EIGVSAVE. The prefix for the file name is
controlled by the I/O option EIGVNAME.
File Contents

Result

Description

Eigenvalue

Eigenvalue results from normal modes analyses.

Comments
1.

This file is used to store eigenvalue results from normal modes analyses for retrieval by
modal frequency response subcases. The EIGVRETRIEVE subcase information entry is
used to retrieve values from this file.

2.

The # in the file name is the integer argument given to EIGVSAVE.

Altair Engineering

OptiStruct 13.0 Reference Guide 2211


Proprietary Information of Altair Engineering

.#.els file
The .#.els file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the PATRAN format is chosen and topology design variables are
present. (See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Density

Density results from topology optimizations. Output is controlled by the


I/O Option DENSRES.

Comments
1.

One such file is created for each iteration where the I/O Option DENSRES requests
topology results to be output.

2.

The # in the file name is the iteration number.

2212 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.els.# file
The .#.els.# file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the APATRAN format is chosen and linear static analysis is performed.
(See documentation for the I/O Option FORMAT).
File Contents

Result

Description

Stress

Stress results from linear static analysis. Output is controlled by the I/O
option STRESS (or ELSTRESS).

Comments
1.

One such file is created for each subcase at each iteration where the I/O option RESULTS
requests analytical results to be output.

2.

The first # in the file name is the user-defined Subcase ID.

3.

The second # in the file name is the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2213


Proprietary Information of Altair Engineering

.#.grid file
The .#.grid file is an OptiStruct ASCII format results file.
File Creation
This file is created when topography or shape optimization is performed. Output of this file is
controlled by the I/O Option SHRES.
File Contents

Result

Description

Nodal locations

The nodal coordinates of the model at iteration # of the


optimization.

File Format
The file uses the following format for each grid in the model:
GRID

Id

Cp

X1

X2

X3

GRID

identifies this as a GRID card image.

Id

is the unique grid point identification number.

Cp

is blank.

Cd

Ps

where:

X1, X2, X3 provide the location of the grid point in the global coordinate
system.
Cd

is the identification number of the coordinate system in which the


displacements, degrees-of-freedom, constraints, and solution
vectors are defined at the grid point.

Ps

is the SPC associated with the grid.

Comments
1.

The # in the file name is the iteration number.

2214 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.h3d file
The .#.h3d files are compressed binary files, containing model, analysis, and optimization
result data. They can be used to post-process results in HyperView or when using the
HyperView Player.
File Creation
The .#.h3d files are created when the OUTPUT, H3D, <frequency>, BYITER output option is
present and an optimization is performed.
File Contents
The .#.h3d files contain node and element definitions. In the case of shape optimization, the
model is updated to the shape of the respective iteration. The following results are included:

Result

Description

Acceleration

Acceleration results from frequency response, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option ACCELERATION.

Composite ply strain

Ply strain results for composite materials from static


analyses.
Output is controlled by the I/O option STRAIN and by the
SOUTi field on the PCOMP definition.

Composite ply stress

Ply stress results for composite materials from static and


analyses.
Output is controlled by the I/O option STRESS and by the
SOUTi field on the PCOMP definition.

Composite failure indices

Failure indices for composite materials from static


analyses.
Output is controlled by the I/O option STRESS, by the
SOUTi, SB and FT fields on the PCOMP definition and by
the related fields on the relevant material definition (see
MAT1, MAT2, MAT8).

Density

Density results from topology optimizations.


Output is controlled by the I/O option DENSITY.

Altair Engineering

OptiStruct 13.0 Reference Guide 2215


Proprietary Information of Altair Engineering

Result

Description

Displacement

Displacement results from static, frequency response,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option DISPLACEMENT.

Eigenvector

Eigenvector results from normal modes and linear buckling


analyses.
Output is controlled by the I/O option DISPLACEMENT.

Element force

Element force results from static, frequency response,


acoustic, and transient response analyses.
Output is controlled by the I/O option FORCE (or
ELFORCE).

Element strain energy

Element strain energy results from static and normal


modes analyses.
Output is controlled by the I/O option ESE.

Grid point stress

Grid point stress results for 3D elements from static


analyses.
Output is controlled by the I/O option GPSTRESS (or
GSTRESS).

Shape

Shape results from topography or shape optimizations.


Output is controlled by the I/O option SHAPE.

Single-point force of
constraint

Single-point force of constraint results from static


analyses.
Output is controlled by the I/O option SPCFORCE.

Strain

Strain results from static, frequency response, transient


response, and multi-body dynamics analyses. Output is
controlled by the I/O option STRAIN.

Stress

Stress results from static, frequency response, transient


response, and multi-body dynamics analyses.

2216 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Result

Description
Output is controlled by the I/O option STRESS (or
ELSTRESS).

Thickness

Thickness results from size and topology optimizations.


Output is controlled by the I/O option THICKNESS.

Velocity

Velocity results from frequency response, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option VELOCITY.

Comments
1.

The # in the file name is the iteration number.

2.

Grid point stresses are output for the entire model and for each individual component.
This allows grid point stresses to be accurately obtained at the interface of two
components referencing different material definitions.

Altair Engineering

OptiStruct 13.0 Reference Guide 2217


Proprietary Information of Altair Engineering

.#.mass file
The .#.mass file is an ASCII format results file.
File Creation
This file is created when modal optimization is performed and OUTPUT,HGEFFMASS is
presented.
File Contents
This file contains the total effective mass fraction.
File Format
The file is formatted into blocks separated by blank lines. Each block represents a modal
subcase. The subcases are in order of occurrence in the input deck.
Each block contains six columns and a number of rows. The number of rows is equal to the
number of requested modes for this subcase. The columns, from left to right, contain the
total effective mass fraction for X-translation, Y-translation, Z-translation, X-rotation, Yrotation, and Z-rotation. The summary of each column is 100%.
Comments
1.

The # in the file name is the iteration number.

2.

This file is used by the _mass.#.mvw session file which automatically creates bar charts
for the results.

2218 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.sens file
The .#.sens file is an OptiStruct ASCII format results file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O Option OUTPUT.
File Content
The file contains sensitivity information for all responses to size and shape design variables at
a given iteration (denoted by the # in the file name).
File Format
The sensitivities are listed in a single column and are grouped by response. A blank line
separates each response grouping.
Comments
1.

The # in the file name is the iteration number.

2.

The _sens.#.mvw HyperView script file automatically creates histogram plots for the
results contained in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2219


Proprietary Information of Altair Engineering

.#.sh file
The .#.sh file is an OptiStruct ASCII format results file.
File Creation
This file is created when an optimization is performed. Output of this file is controlled by the
I/O Option SHRES.
File Contents
Contains information necessary to restart the optimization from a given iteration.
Comments
1. The # in the file name is the iteration number.

2220 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.#.slk file
The .slk file is a Microsoft Excel SYLK Format results file.
File Creation
This file is only created when size or shape optimization is performed. Output of this file is
controlled by the SENSITIVITY and SENSOUT I/O options.
File Contents
The file contains sensitivity information for size and shape design variables.
File Format
The only values that can be changed in this file are those listed in the "New" column. All
other values are either fixed or their calculation is fixed. When the .slk file is created, the
values in the "New" column match those in the "Reference" column. These values may be
adjusted, but should always remain within the design variable's bounds.
Each size and shape design variable in the model is listed in the left-hand column of the
sensitivity table. Information concerning a particular design variable is given in the row where
its label is listed. The current value and the upper and lower bounds of the design variables
are given in the columns, "Reference," "Lower," and "Upper" respectively.
Each referenced response in the model has its own column. These response columns are on
the right-hand side of the sensitivity table. The calculated sensitivity of a response to
changes in a design variable at the current iteration is given in the row corresponding to that
design variable and the column corresponding to that response.
Beneath the list of design variables, in the left-hand column, are the headings "Response lower
bound," "Response reference," and "Response upper bound". If a response is constrained, the
constraint value will be given in either the "Response lower bound" or the "Response upper
bound" row of the column corresponding to that response. The value given in the "Response
reference" row is the calculated value of the response using the design variable reference
values.
At the bottom of the left-hand column are the headings: "Response linear," "Response
reciprocal," and "Response conservative". The response values in these rows are the
predicted values of the responses for three different approximations. Initially, these values
will match one another and the "Response reference" value for each response. This is
because these are the predicted values of the response at the given variable settings, which
initially are the same settings used to calculate the "Response reference" value. Once the
design variable values in the "New" column are altered, these values will change.
The "Response linear" row predicts the response value using linear approximation. This is
calculated as:

where:

Altair Engineering

OptiStruct 13.0 Reference Guide 2221


Proprietary Information of Altair Engineering

R1

is the predicted response value.

R0

is the response reference value.


are the new values of the design variables.
are the reference values of the design variables.

are the sensitivities of the response to the design variables.

The "Response reciprocal" row predicts the response value using reciprocal approximation.
This is calculated as:

where:
R1

is the predicted response value.

R0

is the response reference value.


are the new values of the design variables.

are the reference values of the design variables.

are the sensitivities of the response to the design variables.

The "Response conservative" row predicts the response value using a combination of the
above approximations where linear approximation is used, when the sensitivity is positive, and
reciprocal approximation is used when the sensitivity is negative. Therefore, if all sensitivities
are positive, the conservative prediction will match the linear prediction. If all sensitivities are
negative, it will match the reciprocal prediction, but if there is a mixture of positive and
negative sensitivities for a given response then the conservative prediction will match neither
the linear nor the reciprocal prediction.
The normalized values simply show the predicted response as a fraction of the response
reference value.

2222 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Comments
1.

The # in the file name refers to the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2223


Proprietary Information of Altair Engineering

.amls_singularity.cmf file
The .amls_singularity.cmf file is a HyperMesh command file.
File Creation
This file is created when an AMLS run is performed and singular grid points are detected by
AMLS.
File Contents
This file contains a list of GRID point identification numbers which are found to be singular
during an AMLS run.
Format
*entitysetcreate("^AMLS singular grids",nodes,#)
*createmark(nodes,#)
List of GRID Identification numbers
*entitysetupdate("^AMLS singular grids",nodes,#)
Comments
1.

Verify that the corresponding model is loaded in HyperMesh when executing the command
file.

2224 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.cntf file
The .cntf file is an OptiStruct ASCII format results file.
File Creation
This file is created when the OPTI format is selected in the CONTF I/O Options Entry for
nonlinear quasi-static analysis (NLSTAT) runs.
File Contents
Result

Description

Contact Forces Contact force results from nonlinear quasi-static analysis (with
contact) runs. Output is controlled by the I/O option CONTF.
File Format
The .cntf file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numel

iter

is a keyword identifying that the next field is the iteration number.

Iteration

is the Iteration number.

Numel

is the total number of nonlinear quasi-static subcases (with


contact) in the entire model.

where:

Within the iteration section, the following information is provided for each subcase:
SUBCASE: <Subcase ID> <Number of Contact Interfaces>
LOAD: <Load ID>
LABEL: <Label>
CONTACT INTERFACE: TOTAL FORCE ACTING ON MASTER SURFACE (BASIC SYSTEM)
CONTACT#

Altair Engineering

FORCE-X

FORCE-Y

FORCE-Z

MAGNITUDE

OptiStruct 13.0 Reference Guide 2225


Proprietary Information of Altair Engineering

where:
CONTACT#

is the Contact Interface identification number (CTID on the


CONTACT Bulk Data Entry).

FORCE-X

is the component of the total contact force along the X-axis


of the Basic System.

FORCE-Y

is the component of the total contact force along the Y-axis


of the Basic System.

FORCE-Z

is the component of the total contact force along the Z-axis


of the Basic System.

MAGNITUDE

is the magnitude of the total contact force acting on the


Master Surface

2226 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.contgap.fem file
The .contgap.fem file is an ASCII format file. It is used to visualize the internally created
contact elements. The contact elements are presented as CGAPG elements.
File Creation
This file is created when CONTPRM,CONTGAP,YES is used.
File Contents
The file contains CGAPG elements, PGAP properties, and the auxiliary GRIDs for contact
visualization.
File Format
The formats of GRID, CGAPG, and PGAP are the same as for the bulk data entries.
Comments
1.

To visualize the configuration of the contact elements, load the original FEA model in
HyperMesh and import this file. Ensure that the FE overwrite option is turned on in the
import panel.

2.

During optimization, this file contains the contact elements at the latest iteration. To
visualize this configuration correctly for shape optimization, the shape of the FEA model
should be updated by applying shape change results.

3.

The parameter GAPPRM,GPCOINC is automatically included in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2227


Proprietary Information of Altair Engineering

.cstr file
The .cstr file is an OptiStruct ASCII format results file.
File Creation
This file is created when the OPTI, OS or BOTH formats are chosen. (See documentation for
the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Composite stress or strain

Composite stress and strain results from linear static.


Output is controlled by the I/O options CSTRESS or
CSTRAIN. On PCOMP, SOUT=YES needs to be selected.

File Format
The composite stress file format is self-explanatory. It gives the stress, strain and composite
failure for each element and its plies.
Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

2228 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.dens file
The .dens file is an OptiStruct ASCII format results file.
File Creation
This file is created when the OPTI, OS or BOTH formats are chosen and a topology
optimization is performed. (See documentation for the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Density

Density results from topology optimizations. Output is controlled by the


I/O option DENSRES.

File Format
The density file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numel

iter

is a keyword identifying that the next field is the iteration number.

Iteration

is the Iteration number.

Numel

is the total number of elements in entire model.

where:

Within the iteration section, the following information is provided for each element:
EID

Mat_dens

EID

is the element identification number.

where:

Altair Engineering

OptiStruct 13.0 Reference Guide 2229


Proprietary Information of Altair Engineering

Mat_dens

is the element material density. Non-design elements are


assigned a material density of 1.0.

2230 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.desvar file
The .desvar file is an ASCII format result file.
File Creation
This file is created when OUTPUT,DESVAR is requested in size or shape optimization.
File Contents
This file contains the updated design variables at last iteration.
File Format
The format for design variable output is the same as for the bulk data entries.

Altair Engineering

OptiStruct 13.0 Reference Guide 2231


Proprietary Information of Altair Engineering

.dis.# file
The .dis.# file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the APATRAN format is chosen and shape or topography design
variables are present. (See documentation for the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Shape

Shape results from topography or shape optimizations. Output is controlled


by the I/O option DENSRES.

Comments
1.

One such file is created for each iteration where the I/O option DENSRES requests
topography or shape results to be output.

2.

The # in the file name is the iteration number.

2232 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.disp file
The .disp file is an OptiStruct ASCII format results file.
File Creation
This file is created when the OPTI, OS or BOTH formats are chosen. (See documentation for
the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Acceleration

Acceleration results from frequency response analyses. Output is


controlled by the I/O option ACCELERATION.

Displacement

Displacement results from linear static, inertia relief, and frequency


response analyses. Output is controlled by the I/O option
DISPLACEMENT.

Eigenvector

Eigenvector results from normal modes and linear buckling analyses.


Output is controlled by the I/O option DISPLACEMENT.

Velocity

Velocity results from frequency response analyses. Output is


controlled by the I/O option VELOCITY.

File Format
The displacement file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numids

iter

is a keyword identifying that the next field is the iteration


number.

Iteration

is the iteration number.

Numids

is the number of linear static subcases plus the number of


calculated normal and buckling modes.

where:

Altair Engineering

OptiStruct 13.0 Reference Guide 2233


Proprietary Information of Altair Engineering

Within the iteration section, the following header is used for each linear static subcase,
normal or linear buckling mode, or direct modal frequency response:
LCID

Numnod

Freq

Result: SPCcase (Datatype)

LCID

is the output ID for the subcase or mode. This is not


necessarily the same as the subcase ID defined in the input
data.

Numnod

is the number of grids in the model.

Freq

is the frequency or Buckling eigenvalue (1.0 for static


subcases).

Result

is a keyword declaring the result type given.

where:

DISP indicates displacement result.


VELO indicates a velocity result (for frequency response
analysis only).
ACCE indicates an acceleration result (for frequency response
analysis only).
SPCcase

is the SPC set identification number for linear static, inertia


relief, or frequency response subcases or 1 for eigenvectors.

Datatype

is a keyword indicating the type of subcase involved.


(LOAD) declares data is from a static subcase.
(EIGV) declares data is from a normal modes subcase.
(BKLV) declares data is from a linear buckling subcase.
(DFRQ) declares data is from a direct frequency response
subcase.
(MFRQ) declares data is from a modal frequency response
subcase.

2234 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Within the subcase or mode section, the following information is provided for each
node:
NID

X disp

Y disp

Z disp

NID

is the node identification number.

is the X displacement of the node.

is the Y displacement of the node.

is the Z displacement of the node.

where:

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2235


Proprietary Information of Altair Engineering

.dvgrid file
The .dvgrid file is an OptiStruct ASCII format results file.
File Creation
This file is only created when an analysis is performed. Creation of this file is controlled by
the I/O Option OUTPUT.
File Contents
The file contains shape variable definitions for the displacements or eigenvectors resulting
from linear static, inertia relief, or normal modes analyses.
File Format
DESVAR and DVGRID definitions are provided for each linear static subcase and for each
calculated normal mode.
Output for linear static subcases begins with a header in the following format:
$
$ DESVAR and DVGRIDs for static load case
$

subcase_id

where:
subcase_id

is the user-defined subcase identification number.

Output for calculated normal modes begins with a header in the following format:
$
$ DESVAR and DVGRIDs for eigenvalue load case subcase_id, Mode Number
mode_number
$
where:
subcase_id

is the user-defined subcase identification number.

mode_number is the mode number.


The DESVAR and DVGRID definitions are formatted as per the bulk data descriptions.

2236 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.echo file
The .echo file is an OptiStruct input file.
File Creation
Creation of this file is controlled by the I/O option ECHO = PUNCH.
File Contents
The file represents a copy of the input deck in a form suitable to use for another solution
which, when used with the same subcase information and I/O options entries, should generate
identical results (round off error may be noticeable if the original input deck uses large field
format).

Altair Engineering

OptiStruct 13.0 Reference Guide 2237


Proprietary Information of Altair Engineering

.els.# file
The .els.# file is a Patran 2.5 ASCII format results file.
File Creation
This file is created when the APATRAN format is chosen and topology design variables are
present. (See documentation for the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Density

Density results from topology optimizations. Output is controlled by the


I/O option DENSRES.

Comments
1.

One such file is created for each iteration where the I/O option DENSRES requests
topology results to be output.

2.

The # in the file name is the iteration number.

2238 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.force file
The .force file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the FORCE (ELFORCE) I/O option.
File Contents

Result

Description

Force

Force results from linear static analysis for ELAS (CELAS1, CELAS2,
CELAS3, CELAS4), ROD (CROD), BAR (CBAR, CBEAM), BUSH (CBUSH),
PLATE (CQUAD, CTRIA), and GAP (CGAP) elements.

File Format
The file is divided up by iteration. Output from each iteration starts with a line in the following
format:
ITER

Iteration_number

Number_of_subcases

where:
ITER

is a keyword denoting the beginning of a new iteration.

Iteration_number

is the Iteration number.

Number_of_subcases is the number of subcases for which this output is created.

Each iteration section is divided up by subcase. Output for each subcase starts with a line in
the following format:
Id
Number_of_elements
subcase_label

Frequency

LOAD:Spc_id(Datatype)

where:
ID

is the output identification number for the subcase.


This is not the same as the subcase ID used in the input data.

Number_of_elem is the number of elements for which this output is requested.


ents
Frequency

Altair Engineering

is 1.0 for static analysis.

OptiStruct 13.0 Reference Guide 2239


Proprietary Information of Altair Engineering

LOAD

is a keyword declaring applied load information.

Spc_id

is the SID for SPC's referenced by this subcase.

(Datatype)

is a keyword indicating the type of subcase involved.


(LOAD) declares data is for a linear static subcase.

Each subcase section is divided up by element-type. Output for each element-type section
starts with one of the following formats (depending on the elements present in the model):
ELAS #

FORC E

ROD#

FORC E-A FORC E-B

BUSH#

F-X

F-Y

F-Z

BAR#

END

AXIAL

SHEAR-1 SHEAR-2 TORQUE BENDING BENDING


-1
-2

PLATE#

MEMB-X MEMB-Y

GAP#

C OMP-X SHEAR-Y SHEAR-Z

M-X

MEMB-XY BEND-X

M-Y

BEND-Y

M-Z

TWISTXY

SHEARXZ

SHEARYZ

Element force output is then listed under these headings, depending on the type of elements
for which this output was selected. The format of the element output matches the
corresponding header, that is for ROD elements you would get FORCE-A and FORCE-B;
whereas, for PLATE elements you would get MEMB-X, MEMB-Y, MEMB-XY, BEND-X, BEND-Y,
TWIST-XY, SHEAR-XZ, SHEAR-YZ.
The format is:
Eid

value1

value2

value3

where:
Eid

is the element identification number.

value#

is the Force result corresponding to the column header.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

2240 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.fsthick file
The .fsthick file is an OptiStruct ASCII format file.
File Creation
This file is created when free size optimization is performed and OUTPUT, FSTHICK, YES is
present in the I/O Options section.
File Contents

Result

Description

Element definition

The element definitions for those elements that were part of a free
size design space. The optimized thickness of these elements are
provided as nodal thickness values (Ti).

File Format
The format for the .fsthick file is the same as for the corresponding bulk data entries.

Altair Engineering

OptiStruct 13.0 Reference Guide 2241


Proprietary Information of Altair Engineering

.gpf file
The .gpf file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the GPFORCE I/O option.
File Contents

Result

Description

Grid point force


balance table

Grid point force balance table for linear static analysis.

File Format
The file is divided up by iteration. Output from each iteration starts with a line in the following
format:
ITERATION

Iteration_number

ITERATION

is a keyword denoting the beginning of a new iteration.

Iteration_number

is the Iteration number.

where:

Each iteration section contains a force balance table for each node, for which this output
format was selected, in each linear static subcase.
These tables are given the following header:
Grid point forces for
node

Node_id

Subcase ID =

Subcase_id

where:
Node_id

is the ID of the node to which the force balance table applies.

Subcase_id

is the user-defined subcase ID to which the force balance


table applies.

2242 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

And the force information is provided, for each contributing element, constraint or load, in
the following format:
Force_type Element_id x-force

y-force

z-force

xmoment

y-moment

z-moment

where:
Force_type

is one of:
SPC

Force contribution of single-point constraints.

Appl.

Force contribution of Applied loads.

F-MPC

Force contribution of rigid elements or multi-point


constraints.

Elem

Force contribution of elastic elements.

Total

The sum of all the force contributions.

Element_id

is only valid for force contributions from elastic elements. This is


the element's ID.

x-force

is the x-translational component of the force.

y-force

is the y-translational component of the force.

z-force

is the z-translational component of the force.

x-moment

is the x-rotational component of the force.

y-moment

is the y-rotational component of the force.

z-moment

is the z-rotational component of the force.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2243


Proprietary Information of Altair Engineering

.grid file
The .grid file is an OptiStruct ASCII format results file.
File Creation
This file is created when topography or shape optimization is performed. Output of this file is
controlled by the I/O Option SHRES or by the GRID keyword on the OUTPUT card.
File Contents

Result

Description

Nodal locations

The nodal coordinates of the model for the last iteration of the
optimization.

File Format
The file uses the following format for each grid in the model:
GRID

Id

Cp

X1

X2

X3

Cd

Ps

where:
GRID

identifies this as a GRID card image.

Id

is the unique grid point identification number.

Cp

is the identification number of the coordinate system in which the


location of the grid point is defined.

X1, X2, X3 provide the location of the grid point in the global coordinate
system.
Cd

is the identification number of the coordinate system in which the


displacements, degrees-of-freedom, constraints and solution
vectors are defined at the grid point.

Ps

is the SPC associated with the grid.

2244 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.h3d file
The .h3d file is a compressed binary file, containing both model and result data. It can be
used to post-process results in HyperView or when using the HyperView Player.
File Creation
The .h3d file is created when the H3D format is chosen (see I/O options FORMAT and
OUTPUT), and an analysis only run is performed (meaning no design variables or design spaces
are defined in the model); the I/O option ANALYSIS is present; or the command line switch analysis is used (see Run Options for OptiStruct).
File Contents
The .h3d file contains node and element definitions in addition to the following results:

Result

Description

Acceleration

Acceleration results from frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option ACCELERATION.

Composite ply strain

Ply strain results for composite materials from static


analyses.
Output is controlled by the I/O option STRAIN and by
the SOUTi field on the PCOMP definition.

Composite ply stress

Ply stress results for composite materials from static


and analyses.
Output is controlled by the I/O option STRESS and by
the SOUTi field on the PCOMP definition.

Composite failure indices

Failure indices for composite materials from static


analyses.
Output is controlled by the I/O option STRESS, by the
SOUTi, SB and FT fields on the PCOMP definition and by
the related fields on the relevant material definition
(see MAT1, MAT2, MAT8).

Density

Density results from topology optimizations.


Output is controlled by the I/O option DENSITY.

Altair Engineering

OptiStruct 13.0 Reference Guide 2245


Proprietary Information of Altair Engineering

Result

Description

Displacement

Displacement results from static, frequency response,


acoustic, transient response, and multi-body dynamics
analyses.
Output is controlled by the I/O option DISPLACEMENT.

Eigenvector

Eigenvector results from normal modes and linear


buckling analyses.
Output is controlled by the I/O option DISPLACEMENT.

Element energy loss per cycle Element energy loss per cycle and energy loss per cycle
density output from frequency response analysis.
Output is controlled by the I/O option EDE.
Element force

Element force results from static, frequency response,


acoustic, and transient response analyses.
Output is controlled by the I/O option FORCE (or
ELFORCE).

Element kinetic energy

Element kinetic energy and kinetic energy density


output from frequency response analysis.
Output is controlled by the I/O option EKE.

Element strain energy

Element strain energy and strain energy density results


from static, normal modes and frequency response
analyses.
Output is controlled by the I/O option ESE.

Grid point stress

Grid point stress results for 3D elements from static and


normal modes analyses.
Output is controlled by the I/O option GPSTRESS (or
GSTRESS).

Power flow field

Power flow field output from frequency response and


acoustic analyses.
Output is controlled by the I/O option POWERFLOW.

2246 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Result

Description

Shape

Shape results from topography or shape optimizations.


Output is controlled by the I/O option SHAPE.

SPC force

Single-point force of constraint results from static,


frequency response, acoustic, and transient response
analyses.
Output is controlled by the I/O option SPCFORCE.

Strain

Strain results from static, frequency response,


acoustic, transient response, and multi-body dynamics
analyses. Output is controlled by the I/O option
STRAIN.

Stress

Stress results from static, frequency response,


acoustic, transient response, and multi-body dynamics
analyses.
Output is controlled by the I/O option STRESS (or
ELSTRESS).

Thickness

Thickness results from size and topology optimizations.


Output is controlled by the I/O option THICKNESS.

Velocity

Velocity results from frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option VELOCITY.

Comments
1.

Grid point stresses are output for the entire model and for each individual component.
This allows grid point stresses to be accurately obtained at the interface of two
components referencing different material definitions.

2.

For dynamic analyses like frequency response, transient response, and multi-body
dynamics, it is recommended that sets be used to reduce the amount of model and
results output data. The output file can become very large since results are output for
each frequency or time step.

Altair Engineering

OptiStruct 13.0 Reference Guide 2247


Proprietary Information of Altair Engineering

.hgdata file
The .hgdata file is a HyperGraph ASCII results file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O Option DESHIS.
File Contents
This file may contain the iteration history of the objective function, constraint functions,
design variables, and response functions. Contents of this file are controlled by the I/O
option HISOUT.

2248 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.hist file
The .hist file is an OptiStruct ASCII format results file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O Option DESHIS.
File Contents
This file contains the iteration history of the objective function, maximum constrain violation,
design variables, DRESP1 type responses, and DRESP2 type responses. Contents of this file
are controlled by the I/O option HISOUT.
File Format
The section outlines the format of the .hist OptiStruct ASCII file.

The file uses the following format:


iteration Objective

Max_Const_Violation

Design_variables

DRESP1s

DESP2s

where:
iteration

is the iteration number.

Objective

is the value of the objective function.

Max_Const_Violation is the Maximum constraint violation in %.


Design_variables

is the value of the design variables. Each design variable


is given its own column.

DRESP1s

is the value of the DRESP1s. Each DRESP1 type response


is given its own column.

DESP2s

is the value of the DRESP2s. Each DRESP2 type response


is given its own column.

Comments
1.

The value of each design variable, DRESP1 response and DRESP2 response, is provided in
its own column.

Altair Engineering

OptiStruct 13.0 Reference Guide 2249


Proprietary Information of Altair Engineering

.HM.comp.cmf file
The .HM.comp.cmf file is a HyperMesh command file.
File Creation
The .HM.comp.cmf file is created when a topology optimization is performed (see Topology
Optimization in the OptiStruct User's Guide).
File Contents
When executed in HyperMesh, the .HM.comp.cmf file organizes all elements in the model into
ten new components based on their material densities at the final iteration. The components
are named 0.0-0.1, 0.1-0.2, 0.2-0.3, and so on, up to 0.9-1.0. All elements with a material
density between 0% and 10% are contained in 0.0-0.1. All elements with a material density
between 10% and 20% are contained in 0.1-0.2, and so on. This helps you visualize results
by turning components on and off.
Comments
1.

Ensure the corresponding model is loaded in HyperMesh when executing the command file.

2.

Since elements cannot be in more than one component in HyperMesh, the original
components do not contain any elements.

2250 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.HM.conn.cmf file
The .HM.conn.cmf file is a HyperMesh command file.
File Creation
The .HM.conn.cmf file is created when a topology optimization is performed and 1D elements
form part of the topological design space (see Topology Optimization in the OptiStruct Users
Guide).
File Contents
When executed in HyperMesh, the .HM.conn.cmf file creates connector definitions for those
1D elements which formed part of the topological design space and organizes these
connectors into ten new components based on their material densities at the final iteration.
The components are named 0.0-0.1, 0.1-0.2, 0.2-0.3, and so on, up to 0.9-1.0. The
connector corresponding to those elements with a material density between 0% and 10% are
contained in the 0.0-0.1 component. The connectors corresponding to those elements with a
material density between 10% and 20% are contained in the 0.1-0.2 component, and so on.
This helps you to visualize results by turning components on and off.
Comments
1.

Make sure that the corresponding model is loaded in HyperMesh when executing the
command file.

2.

Connectors are geometric entities in HyperMesh.

Altair Engineering

OptiStruct 13.0 Reference Guide 2251


Proprietary Information of Altair Engineering

.HM.elcheck.cmf file
The .HM.elcheck.cmf file is a HyperMesh command file.
File Creation
The file is created when an element quality check is performed.
File Contents
This file contains results from the following tests:
1.

Element quality tests using ELEMQUAL entry and PARAM, CHECKEL.

2.

Incorrectly formed CFAST and CWELD elements.

3.

CBUSH or CELAS elements with excessive stiffness values (PARAM, BUSHSTIF and PARAM,
ELASSTIF).

When executed in HyperMesh, the .HM.elcheck.cmf file organizes all elements into separate
sets depending on which quality check they fail. One set is created for each failed quality
check. This helps you to visualize results by finding (displaying) elements by set.
Comments
1.

Ensure the corresponding model is loaded in HyperMesh when executing the command file.

2252 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.HM.elcheck.###.cmf file
The .HM.elcheck_###.cmf file is a HyperMesh command file.
File Creation
The file is created, as required, when an element quality check is performed for optimization
iterations.
File Contents
This file contains results from the following tests:
1.

Element quality tests using ELEMQUAL entry and PARAM, CHECKEL.

2.

Incorrectly formed CFAST and CWELD elements.

3.

CBUSH or CELAS elements with excessive stiffness values (PARAM, BUSHSTIF and PARAM,
ELASSTIF).

When executed in HyperMesh, the .HM.elcheck_###.cmf file organizes all elements into
separate sets depending on which quality check they fail. One set is created for each failed
quality check. This helps you to visualize results by finding (displaying) elements by set.
Comments
1.

Ensure the corresponding model is loaded in HyperMesh when executing the command file.

2.

The ### in the file name represents the optimization iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2253


Proprietary Information of Altair Engineering

.HM.ent.cmf file
The .HM.ent.cmf file is a HyperMesh command file.
File Creation
The .HM.ent.cmf file is created when a topology optimization is performed (see Topology
Optimization in the OptiStruct User's Guide).
File Contents
When executed in HyperMesh, the .HM.ent.cmf file organizes all elements in the model into
ten new entity sets based on their material densities at the final iteration. The sets are
named 0.0-0.1, 0.1-0.2, 0.2-0.3, and so on, up to 0.9-1.0. All elements with a material
density between 0% and 10% are contained in 0.0-0.1. All elements with a material density
between 10% and 20% are contained in 0.1-0.2, and so on. You can then visualize the
results by masking the entity sets which contain those elements with lower density.
Comments
1.

Ensure the corresponding model is loaded in HyperMesh when executing the command file.

2.

The advantage of this method over the .HM.comp.cmf method is that the elements
remain in their original components, but can still be selected and masked by entity set.

2254 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.HM.gapstat.cmf file
The .HM.gapstat.cmf file is a HyperMesh command file.
File Creation
This file is created when a nonlinear gap analysis is performed and GAPPRM, HMGAPST is set
as YES or 1.
File Contents
When executed in HyperMesh, the .HM.gapstat.cmf file organizes gap elements into two
sets, open or closed, depending on the status of the gap at the end of the analysis.
Comments
1.

Be sure that the corresponding model is loaded in HyperMesh when executing the
command file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2255


Proprietary Information of Altair Engineering

.html file
The .html file is a HyperText Markup Language file.
File Creation
This file is always output.
File Contents
This file contains a problem summary and results summary of the run.
The problem summary contains information on the finite element model, subcase definitions,
and optimization parameters.
The results summary lists the following results for an analysis or the final iteration of an
optimization:
For linear static subcases:
The maximum displacement and the node where this occurs
The maximum strain energy density and the element where this occurs
The maximum stress and strain for 1D, 2D, and 3D elements and the elements where
these occur
For normal modes subcases:
The frequencies of the calculated modes
The maximum deformation and the node where this occurs
The maximum strain energy density and the element where this occurs
For linear buckling subcases:
The buckling factor for the calculated modes
The maximum deformation and the node where this occurs

2256 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.interface file
The .interface file is an ASCII format results file.
File Creation
This file is always created when acoustic analysis is performed.
File Contents
This acoustic coupling interface matrix visualization file contains element definitions.
Comments
1.

This file is used to verify the fluid/structure coupling matrix.

2.

Import this file into HyperMesh with the acoustic model already loaded. For best
performance, ensure that the FE overwrite option is turned on in the HyperMesh import
panel.

Altair Engineering

OptiStruct 13.0 Reference Guide 2257


Proprietary Information of Altair Engineering

.k.op2 file
The .k.op2 file is a Nastran output2 format file containing the stiffness matrix.
File Creation
This file is created when PARAM, POST, -5 is present in the bulk data section.
File Contents
This file contains the stiffness matrix.

2258 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.load file
The .load file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the OLOAD I/O option.
File Contents

Result

Description

Applied Load

Applied load vectors for linear static analysis.

File Format
The applied load file has the following format:
For each iteration, the following header is used:
iter

Iteration

NumIds

iter

is a keyword denoting the beginning of a new iteration.

Iteration

is the iteration number.

Numids

is the number of subcases for which this output is created.

where:

Each iteration section is divided up by subcase. Output for each subcase starts with a line
in the following format:
Id

Number_of_node
s

Frequency

LOAD:Spc_id(Datatype)

subcase_label

where:
Id

Altair Engineering

is the output identification number for the subcase. This is


not the same as the subcase ID used in the input data.

OptiStruct 13.0 Reference Guide 2259


Proprietary Information of Altair Engineering

Number_of_nodes is the number of nodes for which this output is requested.


Frequency

is 1.0 for static analysis.

LOAD

is a keyword declaring applied load information.

Spc_id

is the SID for SPC's referenced by this subcase.

Datatype

is a keyword indicating the type of subcase involved.


(LOAD) declares data is for a linear static subcase.

The following information is then provided for each node, for which this output was
requested:
NID

X force

Y force

Z force

NID

is the node identification number.

X force

is the X force at the node.

Y force

is the Y force at the node.

Z force

is the Z force at the node.

X mom

is the X moment at the node.

Y mom

is the Y moment at the node.

Z mom

is the Z moment at the node.

X mom

Y mom

Z mom

where:

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
Optimization.

2260 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.m.op2 file
The .m.op2 file is a Nastran output2 format file containing the mass matrix.
File Creation
This file is created when PARAM, POST, -5 is present in the bulk data section.
File Contents
This file contains the mass matrix.

Altair Engineering

OptiStruct 13.0 Reference Guide 2261


Proprietary Information of Altair Engineering

.mass file
The .mass file is an OptiStruct ASCII format results file.
File Creation
This file is only created when modal analyses are performed. Creation of this file is controlled
by the I/O Option OUTPUT.
File Contents

Result

Description

Modal Effective Masses

Modal effective mass results from modal analyses.


Output is controlled by the I/O option OUTPUT,HGEFFMASS.

File Format
The file is formatted into blocks separated by blank lines. Each block represents a modal
subcase; the subcases are in order of occurrence in the input deck.
Each block contains a number of rows equal to the number of requested modes for that
subcase.
The columns, from left to right, contain results for modal effective mass for X-translation, Ytranslation, Z-translation, X-rotation, Y-rotation, and Z-rotation.
Comments
1.

The _mass.mvw HyperView script file automatically creates plots for the results contained
in this file.

2262 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.mnf file
The .mnf file is ADAMS modal neutral file.
File Creatio n
This file is created when OUTPUT, ADAMSMNF is presented during flexible body generation.
File Contents
This file contains the flexible body models.
Comments
1.

If GPSTRESS output is requested in addition to OUTPUT, ADAMSMNF, nodal stress results


for solid elements will be written to this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2263


Proprietary Information of Altair Engineering

.mpcf file
The .mpcf file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the MPCFORCES I/O option.
File Contents

Result

Description

Multi-point force of
constraint

Multi-point force of constraints for linear static analysis.

File Format
The file is divided up by iteration. Output from each iteration starts with a line in the following
format:
ITERATION

Iteration_number

ITERATION

is a keyword denoting the beginning of a new iteration.

Iteration_number

is the iteration number.

where:

Each iteration section contains the multi-point force of constraint for each node, for which
this output format was selected, in each linear static subcase. Each subcase section is
given the following header:
MPC forces for
Subcase

Subcase_id

where:
Subcase_id

is the user-defined subcase ID to which the mpc forces apply.

MPC force information is then provided, for each node, in the following format:

2264 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Node_id

x-force

y-force

z-force

x-moment

y-moment

z-moment

where:
Node_id

is the node identification number.

x-force

is the x-translational component of the force at the node.

y-force

is the y-translational component of the force at the node.

z-force

is the z-translational component of the force at the node.

x-moment

is the x-rotational component of the force at the node.

y-moment

is the y-rotational component of the force at the node.

z-moment

is the z-rotational component of the force at the node.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
Optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2265


Proprietary Information of Altair Engineering

.op2 file
The .op2 file is a Nastran output2 format for model and results data.
File Creation
This file is created when the O2, OUT2, or OUTPUT2 formats are chosen. (See documentation
for the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Acceleration

Acceleration results from frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option ACCELERATION.

Composite ply strain

Ply strain results for composite materials from static analyses.


Output is controlled by the I/O option CSTRAIN and by the
SOUTi field on the PCOMP definition.

Composite ply stress

Ply stress results for composite materials from static analyses.


Output is controlled by the I/O option CSTRESS and by the
SOUTi field on the PCOMP definition.

Composite failure
indices

Failure indices for composite materials from static analyses.


Output is controlled by the I/O option CSTRESS, by the SOUTi,
SB and FT fields on the PCOMP definition, and by the related
fields on the relevant material definition (see MAT1, MAT2,
MAT8).

Density

Density results from topology optimizations.


Output is controlled by the I/O option DENSITY.
Note: Density results are reported as element strain energy.

Displacement

Displacement results from static, frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option DISPLACEMENT.

2266 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Result

Description

Eigenvector

Eigenvector results from normal modes and linear buckling


analyses.
Output is controlled by the I/O option DISPLACEMENT.

Element energy
loss per cycle

Element energy loss per cycle and energy loss per cycle density
output from frequency response analysis.
Output is controlled by the I/O option EDE.

Element force

Element force results from static, frequency response, acoustic,


and transient response analyses.
Output is controlled by the I/O option FORCE (or ELFORCE).

Element kinetic
energy

Element kinetic energy and kinetic energy density output from


frequency response analysis.
Output is controlled by the I/O option EKE.

Element strain
energy

Element strain energy and strain energy density results from


static, normal modes, frequency response, and transient
response analyses.
Output is controlled by the I/O option ESE.

Grid point stress

Grid point stress results for 3D elements from static analyses.


Output is controlled by the I/O option GPSTRESS (or GSTRESS).

MPC force

Multi-point force of constraint results from static, frequency


response, acoustic, and transient response analyses.
Output is controlled by the I/O option MPCFORCE.

PSD element strain

Power spectral density function of element strains from random


response analysis.
Output is controlled by the I/O option STRAIN.

PSD element stress

Altair Engineering

Power spectral density function of element stresses from


random response analysis.

OptiStruct 13.0 Reference Guide 2267


Proprietary Information of Altair Engineering

Result

Description
Output is controlled by the I/O option STRESS.

RMS element strain

Root mean square value of element strains from random


response analysis.
Output is controlled by the I/O option STRAIN.

RMS element stress

Root mean square value of element stresses from random


response analysis.
Output is controlled by the I/O option STRESS.

SPC force

Single-point force of constraint results from static, frequency


response, acoustic, and transient response analyses.
Output is controlled by the I/O option SPCFORCE.

Strain

Strain results from static, frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRAIN.

Stress

Stress results from static, frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRESS (or ELSTRESS).

Velocity

Velocity results from frequency response, acoustic, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option VELOCITY.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

2.

In addition to the analysis and optimization results, the finite element model description
(nodes, elements, coordinates systems, and properties) is written to the .op2 file. This
model can be read by HyperView and fatigue codes. To turn off the model output, use
the NOMODEL option on OUTPUT, OP2.

3.

To be able to read the model directly from the .op2 file, newer versions of FEMFAT,
Medina (7.4.8 or newer), and Animator (3.0.6.6c or newer) must be used.

2268 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

4.

For dynamic analyses like frequency response, transient response, and multi-body
dynamics, it is recommended that sets be used to reduce the amount of model and
results output data. The output file can become very large since results are output for
each frequency or time step.

Altair Engineering

OptiStruct 13.0 Reference Guide 2269


Proprietary Information of Altair Engineering

.oss file
The .oss file is an OSSmooth parameter file.
File Creation
This file is created when a topology, topography, or shape optimization is performed.
File Contents
The file contains default settings for running OSSmooth after a successful optimization.
Comments
1.

The format of this file is described on the OSSmooth Input Data page.

2270 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.out file
The .out file is an ASCII format results file.
File Creation
This file is always created.
File Contents
This file provides a commentary on the solution process.
File Format
The file starts with an OptiStruct banner, and is followed by three sections which outline the
problem definition:
Optimization File and Parameter Information
Finite Element Model Data Information
Optimization Problem Parameters
Following these, calculated estimates on required memory and disk space are provided under
the headings:
Memory Estimation Information
Disk Space Estimation Information
The Analysis Results or Optimization History information sections provide the following
information (Some information is output for each iteration during optimization, or as a summary
for nonlinear analysis):
Element quality information (If any of the warning or error limits are exceeded).
Global force balance tables for each linear static subcase. (When SPCFORCE or
GPFORCE is a requested output).
Objective function value
Maximum constrain violation % and the ID of this constraint.
Design volume fraction value if topology design variables are present, otherwise the
total volume is given, and the total mass.
Individual subcase compliances and weightings and the total weighted compliance.
Retained responses table
If the constraint violation is higher than 1%, the constraint is flagged as V (violated). If the
violation is lower than 1%, it is flagged as A (active). For stress constraint in topology
optimization, if there is no violation, it is flagged as Inactive; otherwise, it is flagged as
Active.
User-requested responses table (when RESPRINT or DREPORT is a requested output).

Altair Engineering

OptiStruct 13.0 Reference Guide 2271


Proprietary Information of Altair Engineering

Most violated constraints table.


Design variable values and bounds if shape or size design variables are present.
Designed property/material/connectivity items table if size design variables are present.
A list of calculated buckling modes and their eigenvalues.
A list of calculated normal modes, their frequencies, eigenvalues and weighting and the
value of the frequencies weighted across the reciprocal eigenvalues.
Center of Gravity table
Moment of Inertia table
Regional compliance table

Manufacturing Constraints table for Composite Optimization


An example table is shown below:
COMPOSITE MANUFACTURING CONSTRAINTS
---------------------------------------------------------------------------User-ID
Constraint Information
Status
Max Avg
Pct
Type
Bound Group Elem
Viol. Viol. Viol.
---------------------------------------------------------------------------1 PLYPCT
LOWER
0.0 ALL
Violated
12.1
2.6
2.5
1 PLYPCT
LOWER
90.0 ALL
Violated
3.0
1.6
0.2
1 PLYPCT
UPPER
90.0 ALL
Violated
31.8
5.3 14.6
---------------------------------------------------------------------------Where,
Max Viol. Represents the maximum violation of the specified manufacturing constraint
(Type).
Avg Viol. Represents the average violation of all the violated elements for the
specified manufacturing constraint (Type).
Pct Viol. Represents the percentage of the total number of elements in the design
space for which the specified manufacturing constraint (Type) is violated.
The Constraint Information columns are self-explanatory and may vary from one
constraint type to the other.

Nonlinear Iteration Summary table for Nonlinear Analysis


An example table is shown below:

2272 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Where,
Avg. U Represents the average displacement of all elements for a particular iteration
for a subcase
EUI Represents the relative error in displacements
EPI Represents the error in terms of loads
EWI Represents the error in terms of work
Refer to the Nonlinear Convergence Criteria section of Nonlinear Quasi-Static Analysis
in the Users Guide for more information.
Maximum Plststrn Represents the Maximum Plastic Strain
The Gap and Contact Element Status columns are self-explanatory.
At the end of the file, the following information is provided:
Resource usage information
Compute time information

Altair Engineering

OptiStruct 13.0 Reference Guide 2273


Proprietary Information of Altair Engineering

.pch file
The .pch file is a Nastran punch format results file.
File Creation
This file is created when the NASTRAN or PUNCH formats are chosen. (See documentation for
the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Acceleration

Acceleration results from frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option ACCELERATION.

Density

Density results from topology optimizations.


Output is controlled by the I/O option DENSRES.
Note: Density results are reported as von Mises Strains.

Displacement

Displacement results from static, frequency response, acoustic,


and transient response analyses.
Output is controlled by the I/O option DISPLACEMENT.

Eigenvector

Eigenvector results from normal modes analyses.


Output is controlled by the I/O option DISPLACEMENT.

Element energy
loss per cycle

Element energy loss per cycle and energy loss per cycle density
output from frequency response analysis.
Output is controlled by the I/O option EDE.

Element force

Element force results from static, frequency response, acoustic,


and transient response analyses.
Output is controlled by the I/O option FORCE (or ELFORCE).

Element kinetic
energy

Element kinetic energy and kinetic energy density output from


frequency response analysis.

2274 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Result

Description
Output is controlled by the I/O option EKE.

Element strain
energy

Element strain energy and strain energy density results from


static, normal modes and frequency response analyses.
Output is controlled by the I/O option ESE.

Grid point stress

Grid point stress results for 3D elements from static analysis.


Output is controlled by the I/O option GPSTRESS (or GSTRESS).

MPC force

Multi-point force of constraint results from static, frequency


response, acoustic, and transient response analyses.
Output is controlled by the I/O option MPCFORCE.

PSD acceleration

Power spectral density function of accelerations from random


response analysis. (see comment 2)
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

PSD displacement

Power spectral density function of displacements from random


response analysis. (see comment 2)
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

PSD velocity

Power spectral density function of velocities from random


response analysis. (see comment 2)
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

PSD element strain

Power spectral density function of element strains from random


response analysis. (see comment 2)
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

PSD element stress

Altair Engineering

Power spectral density function of element stresses from


random response analysis. (see comment 2)

OptiStruct 13.0 Reference Guide 2275


Proprietary Information of Altair Engineering

Result

Description
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

RMS element strain

Root mean square value of element strains from random


response analysis.
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

RMS element stress

Root mean square value of element stresses from random


response analysis.
Output is controlled by the I/O options XYPEAK, XYPLOT, and
XYPUNCH.

SPC force

Single-point force of constraint results from linear static


analysis.
Output is controlled by the I/O option SPCFORCE.

Strain

Strain results from static, frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRAIN.

Stress

Stress results from static, frequency response, acoustic,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRESS (or ELSTRESS).

Velocity

Velocity results from frequency response analyses, acoustic,


transient response, and multi-body dynamics.
Output is controlled by the I/O option VELOCITY.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

2.

Multiple RANDOM subcase information entries with non-unique IDs are allowed in a single
model. Therefore, if the plot-type field on the XYPUNCH output request is set to PSDF,
then the RANDOM ID will be added to the XYPUNCH headers in the corresponding result
sections of the .pch file when multiple RANDOM entries are present in the same deck. If
only one RANDOM entry is present, the RANDOM ID is not printed.

2276 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Altair Engineering

OptiStruct 13.0 Reference Guide 2277


Proprietary Information of Altair Engineering

.pcomp file
The .pcomp file is an ASCII format result file.
File Creation
This file is created when OUTPUT,PCOMP is requested in composite sizing optimization.
File Contents
This file contains elements and PCOMPG property information for each STACK.

2278 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.peak file
The .peak file is an ASCII format results file.
File Creation
This file is created when XYPLOT, XYPEAK, or XYPUNCH is requested in random response
analysis.
File Contents
This file contains the root mean square value, the number of positive crossings, and the peak
power spectral density and responses.

Altair Engineering

OptiStruct 13.0 Reference Guide 2279


Proprietary Information of Altair Engineering

.pret file
The .pret file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the PRETBOLT I/O Options Entry.
File Contents
Result

Description

Pretension force/
adjustment

Pretension force/adjustment values for pretension bolts in


pretensioning and pretensioned subcases.

File Format
The file is sorted by iteration. Output from each iteration starts in the following format:
PRETENSION FORCE/ADJUSTMENT VALUES ON THE PRENTESION SECTIONS

ITERATION

Iteration_number

Where:
ITERATION is a keyword denoting the beginning of a new iteration.
Iteration_number is the iteration number.

Each iteration section contains the force/adjustment values for each pretension bolt in
each static subcase. Each such subcase section is given the following header:
Subcase

Subcase_id

Subcase_label

Where:
Subcase is a keyword denoting the beginning of the current subcase section.
Subcase_id is the user-defined subcase ID
Subcase_label is the user-defined subcase label

2280 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Pretension force/adjustment information is then provided, for each bolt, in the following
format:
Pretension
section ID
(PRETENS #)

Force-incr

Adjust-incr

Force-tot

Adjusttot

Where:
Pretension section ID denotes the pretension section ID (SID of the PRETENS bulk data
entry).
Force-incr is the incremental pretension force value when compared to the previous
subcase in the loading sequence.
Adjust-incr is the incremental pretension adjustment value when compared to the
previous subcase in the loading sequence.
Force-tot is the total pretension force value.
Adjust-tot is the total pretension adjustment value.
Comments
1. The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2281


Proprietary Information of Altair Engineering

.prop file
The .prop file is an OptiStruct ASCII format result file.
File Creation
This file is output when sizing optimization is performed. Creation of this file is controlled by
the PROPERTY I/O option.
File Contents

Result

Description

Property definition

The property definitions, for those properties that were affected


in the sizing optimization, used for the final iteration of the
optimization.

File Format
The format for the property output is the same as for the bulk data entries.

2282 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.rand file
The .rand file is an OptiStruct ASCII format results file.
File Creation
This file is only created for random response subcases. This file is only created if XYPLOT is
defined in random response.
File Contents

Result

Description

Random response results

Results from random response analyses.

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _rand.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2283


Proprietary Information of Altair Engineering

.res file
The .res file is a HyperMesh binary results file.
File Creation
The .res file is created when either no format statement is given or when the HM, HYPER, or
BOTH formats are chosen. (See documentation for the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Acceleration

Acceleration results from frequency response, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option ACCELERATION.

Composite ply strain

Ply strain results for composite materials from static


analyses.
Output is controlled by the I/O option STRAIN and by the
SOUTi field on the PCOMP definition.

Composite ply stress

Ply stress results for composite materials from static


analyses.
Output is controlled by the I/O option STRESS and by the
SOUTi field on the PCOMP definition.

Composite failure indices

Failure indices for composite materials from static analyses.


Output is controlled by the I/O option STRESS, by the
SOUTi, SB and FT fields on the PCOMP definition, and by the
related fields on the relevant material definition (see MAT1,
MAT2, MAT8).

Density

Density results from topology optimizations.


Output is controlled by the I/O option DENSITY.

Displacement

Displacement results from static, frequency response,


transient response, and multi-body dynamics analyses.
Output is controlled by the I/O option DISPLACEMENT.

2284 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Result

Description

Eigenvector

Eigenvector results from normal modes and linear buckling


analyses.
Output is controlled by the I/O option DISPLACEMENT.

Element strain energy

Element strain energy results from static and normal modes


analyses.
Output is controlled by the I/O option ESE.

Grid point stress

Grid point stress results for 3D elements from static


analyses.
Output is controlled by the I/O option GPSTRESS (or
GSTRESS).

Shape

Shape results from topography or shape optimizations.


Output is controlled by the I/O option SHAPE.

Single-point force of
constraint

Single-point force of constraint results from static analyses.


Output is controlled by the I/O option SPCFORCE.

Strain

Strain results from static, frequency response, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRAIN.

Stress

Stress results from static, frequency response, transient


response, and multi-body dynamics analyses.
Output is controlled by the I/O option STRESS (or
ELSTRESS).

Thickness

Thickness results from size and topology optimizations.


Output is controlled by the I/O option THICKNESS.

Velocity

Velocity results from frequency response analyses, transient


response, and multi-body dynamics.
Output is controlled by the I/O option VELOCITY.

Altair Engineering

OptiStruct 13.0 Reference Guide 2285


Proprietary Information of Altair Engineering

Comments
1.

If an optimization is terminated abruptly due to an error such as a full disk or power


failure, the HyperMesh binary results file (*.res) may become corrupted. In this event,
run the program "recover," included with OptiStruct, to clean up the results file.

2.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

3.

Grid point stresses are output for the entire model and for each individual component.
This allows grid point stresses to be accurately obtained at the interface of two
components referencing different material definitions.

4.

For dynamic analyses, like frequency response, transient response, and multi-body
dynamics, it is recommended that sets be used to reduce the amount of model and
results output data. The output file can become very large since results are output for
each frequency or time step.

2286 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.seplot file
The .seplot file is an ASCII format output file.
File Creation
This file is created when the MODEL, PLOT, and PARAM, SEPLOT, YES options are presented
and the CBN method is used to reach a Component Mode Synthesis solution.
File Contents
This file contains grid and plot element definitions.
Comments
1.

By including this file in a residual run, the results of the superelement part will be
recovered and post-processed.

Altair Engineering

OptiStruct 13.0 Reference Guide 2287


Proprietary Information of Altair Engineering

.sh file
The .sh file is an OptiStruct ASCII format results file.
File Creation
This file is created when an optimization is performed. Output of this file is controlled by the
I/O option SHRES.
File Contents
Contains information necessary to restart the optimization from the final iteration.

2288 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.spcd file
The .spcd file is an OptiStruct ASCII format results file.
File Creation
This file is created in a residual run when DMIG's are present in the model. The .spcd file
contains displacement results at interface grid points.
File Contents
Result

Description

Displacement

Displacement results from a residual run. Output is controlled by


the I/O option DISPLACEMENT.

File Format
The .spcd file has the following format:
For each iteration, the following header is used:
SUBCASE

SID

SID

is the identification number of the corresponding subcase.

where:

Under each applicable subcase header, we have the following columns:


SPC

####SID GRID ID

Component

Displacement

SID

is the identification number of the corresponding subcase.

GRID ID

is the identification number of the interface grid at which


the displacement results are output.

Component

is the component in which the displacement result output.

where:

Displacement is the displacement result for a give grid in the


corresponding component.

Altair Engineering

OptiStruct 13.0 Reference Guide 2289


Proprietary Information of Altair Engineering

Comments
1.

Only one .spcd file is created even if there are multiple DMIGs in the model.

2290 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.spcf file
The .spcf file is an OptiStruct ASCII format results file.
File Creation
Creation of this file is controlled by the SPCFORCES I/O option.
File Contents

Result

Description

Single-point force of
constraint

Single-point force of constraints for linear static


analysis.

File Format
The SPC reaction force file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numlds

iter

is a keyword denoting the beginning of a new iteration.

Iteration

is the iteration number.

Numlds

is the number of subcases for which this output is created.

where:

Each iteration section is divided up by subcase. Output for each subcase starts with a line
in the following format:
Id

Number_of_nodes

Frequency

SPCF:Spc_id(Datatype)

subcase_label

where:
Id

Altair Engineering

is the output identification number for the subcase. This is


not the same as the subcase ID used in the input data.

OptiStruct 13.0 Reference Guide 2291


Proprietary Information of Altair Engineering

Number_of_nodes

is the number of nodes for which this output is requested.

Frequency

is 1.0 for static analysis.

SPCF

is a keyword declaring SPC-force information.

Spc_id

is the SID for SPC's referenced by this subcase.

Datatype

is a keyword indicating the type of subcase involved.


(LOAD) declares data is for a linear static subcase.

SPC-force information is then provided, for each node, in the following format:
Node_id

x-force

y-force

z-force

x-moment

y-moment z-moment

where:
Node_id

is the node identification number.

x-force

is the x-translational component of the force at the node.

y-force

is the y-translational component of the force at the node.

z-force

is the z-translational component of the force at the node.

x-moment

is the x-rotational component of the force at the node.

y-moment

is the y-rotational component of the force at the node.

z-moment

is the z-rotational component of the force at the node.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
Optimization.

2292 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

.stat file
The .stat file is an ASCII format results file.
File Creation
This file is always created.
File Contents
This file provides details on CPU and elapsed time for each solver module.
File Format
Information on CPU and elapsed time is provided in the following format:
TOTAL TIME SPENT IN MODULE: module_name; CPU= cpu_time; WALL= wall_time
where:

module_name is the name of the module.


cpu_time

is the amount of CPU time spent in this module.

wall_time

is the total elapsed time spent in this module.

Altair Engineering

OptiStruct 13.0 Reference Guide 2293


Proprietary Information of Altair Engineering

.strn file
The .strn file is an ASCII format results file.
File Creation
This file is created when OPTI, OS, or ASCII formats are chosen. (See documentation for the
I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Strain

Strain results from linear static analysis. Output is controlled by the I/O
option STRAIN.

File Format
The strain file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numlds

iter

is a keyword denoting the beginning of a new iteration.

Iteration

is the Iteration number.

Numlds

is the number of load cases for which this output is created.

where:

Each iteration section is divided up by subcase. Output for each subcase starts with a line
in the following format:
Id

Number_of_els

STRN:Spc_id

where:
Id

is the output identification number for the subcase. This is


not the same as the subcase ID used in the input data.

2294 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Number_of_els

is the number of elements for which this output is requested.

STRN

is a fixed keyword.

Spc_id

is the SID for SPC's referenced by this subcase.

Datatype

is a keyword indicating the type of subcase involved.


(LOAD) declares data is for a linear static subcase.

Strain information is then provided, for each element, in the following format:
EID

Strain1

Strain2

Strain3

Strain4

Strain5

Strain6

Strain7

where:
EID

is the element identification number.

Strain1

is von Mises strain for 2D and 3D elements, or Axial strain for 1D


elements.

Strain2

is Normal X-strain at Z1 for 2D elements, Normal X-strain for 3D


elements, or Axial strain for 1D elements.

Strain3

is Normal X-strain at Z2 for 2D elements, Normal Y-strain for 3D


elements, or Axial strain for 1D elements.

Strain4

is Normal Y-strain at Z1 for 2D elements, Normal Z-strain for 3D


elements, or Axial strain for 1D elements.

Strain5

is Normal Y-strain at Z2 for 2D elements, Shear XY-strain for 3D


elements, or Axial strain for 1D elements.

Strain6

is Shear XY-strain at Z1 for 2D elements, Shear YZ-strain for 3D


elements, or Axial strain for 1D elements.

Strain7

is Shear XY-strain at Z2 for 2D elements, Shear XZ-strain for 3D


elements, or Axial strain for 1D elements.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2295


Proprietary Information of Altair Engineering

.strs file
The .strs file is an OptiStruct ASCII format results file.
File Creation
This file is created when the OPTI, OS or BOTH formats are chosen. (See documentation for
the I/O options FORMAT and OUTPUT).
File Contents

Result

Description

Stress

Stress results from linear static analysis. Output is controlled by the I/O
option STRESS (or ELSTRESS).

File Format
The stress file has the following format:
For each iteration, the following header is used:
iter

Iteration

Numlds

iter

is a keyword denoting the beginning of a new iteration.

Iteration

is the Iteration number.

Numlds

is the number of load cases for which this output is created.

where:

Each iteration section is divided up by subcase. Output for each subcase starts with a line
in the following format:
Id

Number_of_els

STRS:Spc_id(Datatype)

where:
Id

is the output identification number for the subcase. This is not


the same as the subcase ID used in the input data.

2296 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Number_of_els

is the number of elements for which this output is requested.

STRS

is a fixed keyword.

Spc_id

is the SID for SPC's referenced by this subcase.

Datatype

is a keyword indicating the type of subcase involved.


(LOAD) declares data is for a linear static subcase.

Stress information is then provided, for each element, in the following format:
EID

Stress1

S Stress3
t
r
e
s
s
2

S Stress5
t
r
e
s
s
4

Stress6

Stress7

Stress8

Stress9

where:
EID

Element identification number.

Stress1

von Mises stress for 2D and 3D elements, Maximum Axial stress for 1D
elements, or maximum stress in CWELD elements.

Stress2

Normal X-stress at Z1 for 2D elements, Normal X-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at C at end A. Axial Stress for CWELD
elements.

Stress3

Normal X-stress at Z2 for 2D elements, Normal Y-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at D at end A. Maximum tensile stress at
end A for CWELD elements.

Stress4

Normal Y-stress at Z1 for 2D elements, Normal Z-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at E at end A. Minimum tensile stress at

Altair Engineering

OptiStruct 13.0 Reference Guide 2297


Proprietary Information of Altair Engineering

end A for CWELD elements.


Stress5

Normal Y-stress at Z2 for 2D elements, Shear XY-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at F at end A. Maximum tensile stress at
end B for CWELD elements.

Stress6

Shear XY-stress at Z1 for 2D elements, Shear YZ-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at C at end B. Minimum tensile stress at
end B for CWELD elements.

Stress7

Shear XY-stress at Z2 for 2D elements, Shear XZ-stress for 3D


elements, or Axial stress for 1D elements.
For BAR/BEAM it is the stress at D at end B. Maximum shear stress for
CWELD elements.

Stress8

Maximum shear stress for CWELD elements.


For BAR/BEAM it is the stress at E at end B. Bearing stress for CWELD
elements.

Stress9

Bearing stress for CWELD elements.


For BAR/BEAM it is the stress at F at end B.

Comments
1.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

2298 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_des.h3d file
The _des.h3d file is a compressed binary file, containing both model and result data. It can
be used to post-process results in HyperView or when using the HyperView Player.
File Creation
The _des.h3d file is created when the H3D format is chosen (see documentation for the I/O
option FORMAT), and an optimization run is performed.
File Contents
The _des.h3d file contains node and element definitions in addition to the following results:

Result

Description

Density

Density results from topology optimizations. Output is controlled by the


I/O option DENSRES.

Shape

Shape results from topography or shape optimizations. Output is


controlled by the I/O option DENSRES.

Thickness

Thickness results from size and topology optimizations. Output is


controlled by the I/O option DENSRES.

Altair Engineering

OptiStruct 13.0 Reference Guide 2299


Proprietary Information of Altair Engineering

_err.grid file
The _err.grid file is an OptiStruct ASCII format results file.
File Creation
This file is automatically created when freeshape and topography (or shape) optimization runs
are terminated due to mesh distortion.
File Contents
Result

Description

Nodal locations

It contains the nodal coordinates of the distorted mesh for


freeshape and topography (or shape) optimization.

File Format
The file uses the following format for each grid in the model:
GRID

Id

Cp

X1

X2

X3

GRID

identifies this as a GRID card image.

Id

is the unique grid point identification number.

Cp

is blank.

Cd

Ps

where:

X1, X2, X3 provide the location of the grid point in the global coordinate
system.
Cd

is the identification number of the coordinate system in which the


displacements, degrees-of-freedom, constraints, and solution
vectors are defined at the grid point.

Ps

is the SPC associated with the grid.

2300 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_frames.html file
The _frames.html file is a HyperText Markup Language file.
File Creation
This file is output when the H3D FORMAT is chosen.
File Contents
The file contains two frames. The top frame opens one of the .h3d files using the HyperView
Player browser plug-in. The .h3d file opened depends on the results selected for display in
the bottom frame. The bottom frame opens the _menu.html file, which facilitates the
selection of results to be displayed.
Comments
1.

Requires HyperView Player plug-in to be installed.

2.

This file is linked to from the "Results summary" section of the .html file and is created
primarily for this purpose.

Altair Engineering

OptiStruct 13.0 Reference Guide 2301


Proprietary Information of Altair Engineering

_freq.#.mvw file
The _freq.#.mvw file is a HyperView session file.
File Creation
This file is created when frequency response optimization is performed and OUTPUT,HGFREQ is
requested.
Comments
1.

The # in the file name is the iteration number.

2.

This file may be opened from the File menu in HyperView or HyperGraph. It automatically
creates plots for the results contained in the files: _s#_a.#.frf, _s#_d.#.frf, and
_s#_v.#.frf.

2302 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_freq.mvw file
The _freq.mvw file is a HyperView session file.
File Creation
This file is only created when frequency response analysis is performed. Creation of this file is
controlled by the I/O option OUTPUT.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates plots for each of the results contained in the
files: _s#_a.frf, _s#_d.frf, and _s#_v.frf.

Altair Engineering

OptiStruct 13.0 Reference Guide 2303


Proprietary Information of Altair Engineering

_gauge.h3d file
The _gauge.h3d file is a compressed binary file containing both model and result data. It can
be used to post-process shell thickness (gauge) sensitivity in HyperView.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O option OUTPUT.
File Contents
The _gauge.h3d file contains node and element definitions in addition to the following results:

Result

Description

Sensitivity

Sensitivity of response vs. shell thickness (gauge) of PSHELL property.


Output is controlled by the I/O option OUTPUT.

Comments
1.

The # in the file name is the iteration number.

2304 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_gso.slk file
The _gso.slk file is a Microsoft SLK Data Import format results file.
File Creation
This file is created when Global Search Option (GSO) is activated and executed using the
DGLOBAL I/O entry and the DGLOBAL Bulk Data entry, respectively. This file outputs the
results of Global Search Option (GSO).
File Contents
Result

Description

Optimized Designs

It contains the list of unique and similar optimized designs based


on the Global Search Option (GSO) method. The designs in this
resulting subset of the total design space are then sorted based
on their rank (based on the number of convergences from unique
starting points to result in a specific design).

File Format
The file uses the following format for the designs optimized from specified starting points:
Unique Designs
Design
Rank

Startin
g Point

Times
Found

Directo
ry
Name

Objecti
ve
Functio
n

C onstr
aint
Violatio
n

Max.
Obj.
Deviati
on

Avg.
Obj.
Deviati
on

Max.
DV
Deviati
on

Avg.
DV
Deviati
on

DV1

DVN

All Designs
Design
Rank

Starting
Point

Unique
Design

Directory
Name

Objective
Function

C onstraint DV1
Violation

DVN

Where,
Design Rank

Denotes the rank of the design. This is assigned based initially on the values
of Constraint Violation and then the Objective Function values.

Starting Point

Denotes the starting point of the optimization for a design in the design
space.

Times Found

The number of times designs (from unique starting points) converge to the
same design.

Directory
Name

Name of the Directory where the output files associated with the specified
design are stored.

Altair Engineering

OptiStruct 13.0 Reference Guide 2305


Proprietary Information of Altair Engineering

Objective
Function

The value of the Objective Function for the current design.

Constraint
Violation

The value of the Constraint Violation for the current design

Maximum
Objective
Deviation

The maximum deviation (of a design) from the objective function among
designs from unique starting points that converged to this unique design.

Average
Objective
Deviation

The average deviation (of a design) from the objective function among
designs from unique starting points that converged to this unique design.

Maximum DV
Deviation

The maximum deviation between two design variables in the design space
among designs from unique starting points that converged to this unique
design.

Average DV
Deviation

The average deviation between design variables in the design space among
designs from unique starting points that converged to this unique design.

DV#

The various design variables values represented by DV1, DV2,.., DVN.

Unique Design This represents the Design Rank used in the UNIQUE DESIGN Table.

2306 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_hist.mvw file
The _hist.mvw file is a HyperView session file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O option DESHIS.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates individual plots for each of the results contained in
the .hist file. Each plot occupies its own page within HyperView (HyperGraph).

Altair Engineering

OptiStruct 13.0 Reference Guide 2307


Proprietary Information of Altair Engineering

_mass.#.mvw file
The _mass.#.mvw file is a HyperView session file.
File Creation
This file is created when modal optimization is performed and OUTPUT,HGEFFMASS is
requested.
Comments
1.

The # in the file name is the iteration number.

2.

This file may be opened from the File menu in HyperView or HyperGraph. It automatically
creates bar charts for the results contained in .#.mass file.

2308 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_mass.mvw file
The _mass.mvw file is a HyperView session file.
File Creation
This file is only created when modal analyses are performed. Creation of this file is controlled
by the I/O option OUTPUT.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates plots for the results contained in the .mass file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2309


Proprietary Information of Altair Engineering

_mbd.h3d file
The _mbd.h3d file is a compressed binary file containing both model and result data from a
multi-body dynamics analysis. It can be used to post-process results in HyperView.
File Creation
This file is created when a multi-body dynamics subcase is executed.
File Contents
The _mbd.h3d file contains node and element definitions in addition to the following results:

Result

Description

Displacement

Displacement results from static, frequency response,


transient response, and multi-body dynamics analyses.

Deformation > Displacement

Deformations (deflections) of flexible bodies from multibody dynamics analyses in the body reference frame.

Deformation > Rotation

Deformation (rotations) of flexible bodies from multi-body


dynamics analyses in the body reference frame.

Strain

Strain results of flexible bodies from a multi-body


dynamics analysis.

Stress

Stress results of flexible bodies from a multi-body


dynamics analysis.

Comments
1.

This file format is the most compressed animation output for multi-body dynamics
analyses. It generates the smallest files compared to other formats.

2310 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_mbd.log file
The _mbd.log file is an ASCII format log file from a multi-body dynamics analysis.
File Creation
This file is created when a multi-body dynamics subcase is executed. It is a direct output file
of MotionSolve.
File Contents
The file provides commentary on the multi-body dynamics solution progress.

Altair Engineering

OptiStruct 13.0 Reference Guide 2311


Proprietary Information of Altair Engineering

_mbd.mrf file
The _mbd.mrf file is a Multi-body Results File.
File Creation
This file is created when a multi-body dynamics subcase is defined. The file contains time
history data that can be used for 2D plotting in HyperGraph. Some data is written by default,
and some needs to be requested.
File Contents
Data output by default.

Type

Component

Description

Rigid Body

X, Y, Z

Position

E0, E1, E2, E3

Orientation in Euler parameters.

VM, VX, VY, VZ

Magnitude and X, Y, Z components


of velocity.

WM, WX, WY, WZ

Magnitude and X, Y, Z components


of angular velocity.

ACCM, ACCX, ACCY, ACCZ

Magnitude and X, Y, X components


of acceleration.

WDTM, WDTX, WDTY, WDTZ

Magnitude and X, Y, Z components


of angular acceleration.

KE

Kinetic energy

Flex Body

All Rigid Body results


Q/i, i = 1,2,,n

Modal participation factors.

XD/i, i=1,2,,N

Modal velocity.

2312 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Type

Component

Description

System

KE

Kinetic energy

CPU Usage

Total CPU time used.

CPU/Sim. Time Ratio

The ration between the total CPU


time used and the simulation time.

Stepsize

Actual step size used in the


integration.

Integration Order

Order of the integrator used in the


integration.

Data output by request. The request needs to be defined through a REQUEST I/O statement.

Type

Component

Description

Marker Displacement DM, DX, DY, DZ

Marker Velocity

Marker Acceleration

Altair Engineering

Magnitude and X, Y, Z components


of displacement.

E0, E1, E2, E3

Orientation in Euler parameters.

VM, VX, VY, VZ

Magnitude and X, Y, Z components


of velocity.

WM, WX, WY, WZ

Magnitude and X, Y, Z components


of angular velocity.

ACCM, ACCX, ACCY, ACCZ

Magnitude and X, Y, Z components


of acceleration.

WDTM, WDTX, WDTY, WDTZ

Magnitude and X, Y, Z components


of angular acceleration.

OptiStruct 13.0 Reference Guide 2313


Proprietary Information of Altair Engineering

Type

Marker Force

Expressions

Component

Description

FM, FX, FY, FZ

Magnitude and X, Y, Z components


of force.

TM, TX, TY, TZ

Magnitude and X, Y, Z components


of torque.

F1, F2, , F8

Vectors containing evaluated


expressions.

2314 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_mbd.mvw file
The _mbd.mvw file is a HyperView session file.
File Creation
This file is only created when a multi-body dynamics analysis is performed. Creation of this
file is controlled by the I/O option OUTPUT.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates plots for each of the results contained in the
files: _s#_a.mbd, _s#_d.mbd, and _s#_v.mbd.

Altair Engineering

OptiStruct 13.0 Reference Guide 2315


Proprietary Information of Altair Engineering

_mbd.xml file
The _mbd.xml file is a MotionSolve XML file from a multi-body dynamics analysis.
File Creation
This file is created when a multi-body dynamics subcase is executed.
File Contents
The file format is documented in the MotionSolve manual. The purpose is the communication
between the OptiStruct core and the integrated MotionSolve. This file, together with the
<BODY_NAME>.h3d files, forms a full representation of the multi-body dynamics model which
can be run separately in MotionSolve.

2316 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_menu.html file
The _menu.html file is a HyperText Markup Language file.
File Creation
This file is output when the H3D FORMAT is chosen.
File Contents
This file facilitates the selection of the appropriate .h3d file, for the HyperView Player browser
plug-in in the top frame of the _frames.html file, based on chosen results.
Comments
1.

This file serves no purpose on its own.

Altair Engineering

OptiStruct 13.0 Reference Guide 2317


Proprietary Information of Altair Engineering

_modal.#.mvw file
The _modal.#.mvw file is a HyperView session file.
File Creation
This file is only created for frequency response and transient analyses. Creation of this file is
controlled by the I/O option OUTPUT (with the HGMODFAC keyword).
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph3D. The file contains HyperGraph3D plots of modal participation factors. The plots
display the mode number on the x-axis, the frequency (for frequency response analyses) or
time (for transient analyses) on the y-axis, and the modal participation factor on the z-axis.
In HyperGraph3D, it is possible to define cross-sections to generate 2D plots of either:
Modal participation factor vs. frequency or time for a given mode number
Modal participation factor vs. mode number at a given frequency or time
For frequency response analyses, plots are generated for the real part, the imaginary part and
the magnitude of the participation factors. Magnitude plot is visible by default, while real and
imaginary plots are hidden by default.
Comments
1.

The # in the file name is the iteration number.

2318 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_modal.mvw file
The _modal.mvw file is a HyperView session file.
File Creation
This file is only created for frequency response and transient analyses. Creation of this file is
controlled by the I/O option OUTPUT (with the HGMODFAC keyword).
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph3D. The file contains HyperGraph3D plots of modal participation factors. The plots
display the mode number on the x-axis, the frequency (for frequency response analyses) or
time (for transient analyses) on the y-axis, and the modal participation factor on the z-axis.
In HyperGraph3D, it is possible to define cross-sections to generate 2D plots of either:
Modal participation factor vs. frequency or time for a given mode number
Modal participation factor vs. mode number at a given frequency or time
For frequency response analyses, plots are generated for the real part, the imaginary part and
the magnitude of the participation factors. Magnitude plot is visible by default, while real and
imaginary plots are hidden by default.
Comments
1.

This file is generated for an analysis-only run; the _modal.#.mvw is generated for
optimization runs where # is the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2319


Proprietary Information of Altair Engineering

_rand.mvw file
The _rand.mvw file is a HyperView session file.
File Creation
This file is only created when random response analysis is performed. This file is only created
if XYPLOT is defined in random response.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates plots for each of the results contained in .rand
files.

2320 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_s#.h3d file
The _s#.h3d file is a compressed binary file, containing both model and result data. It can be
used to post-process results in HyperView or using the HyperView Player.
File Creation
The _s#.h3d file is created when the H3D format is chosen (See documentation for the I/O
option FORMAT), and an optimization is performed containing a linear static subcase. A similar
file is created for each static subcase.
File Contents
The _s#.h3d file contains node and element definitions in addition to the following results:

Result

Description

Displacement

Displacement results from linear static analysis. Output is


controlled by the I/O option DISPLACEMENT.

Element strain energy

Element strain energy results from linear static analysis.


Output is controlled by the I/O option ESE.

Stress

Stress results from linear static analysis. Output is controlled


by the I/O option STRESS (or ELSTRESS).

Density

Density results from topology optimization. Output is controlled


by the I/O option DENSITY.

Shape

Shape results from topography, shape, and free shape


optimization. Output is controlled by the I/O option SHAPE.

Comments
1.

The # in the file name is the user-defined subcase ID.

2.

The I/O option RESULTS controls the frequency of output for analytical results during an
optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2321


Proprietary Information of Altair Engineering

_s#_a.#.frf file
The _s#_a.#.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response optimization. Output is controlled by the I/O
option ACCELERATION and OUTPUT,HGFREQ.
File Contents
This file contains the acceleration results from frequency response optimization.
File Format
If the real and imaginary format was selected on the ACCELERATION card, the file starts with
the following header:
Frequency "REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans
If the phase and magnitude format was selected on the DISPLACEMENT card, the file starts
with the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case, the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle


in the x-direction component.

X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

2322 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The first # in the file name is the user-defined subcase ID.

2.

The second # in the file name is the iteration number.

3.

The_freq.#.mvw HyperView script file automatically creates plots for the results
contained in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2323


Proprietary Information of Altair Engineering

_s#_a.frf file
The _s#_a.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Acceleration

Acceleration results from frequency response analyses. Output is


controlled by the I/O option ACCELERATION.

File Format
If the real and imaginary format was selected on the ACCELERATION card, the file starts with
the following header:
Frequency"REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans

If the phase and magnitude format was selected on the ACCELERATION card, the file starts
with the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle

2324 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

in the x-direction component.


X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _freq.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2325


Proprietary Information of Altair Engineering

_s#_a.mbd file
The _s#_a.mbd file is an OptiStruct ASCII format results file.
File Creation
This file is only created for Multi-Body Dynamics subcases. Creation of this file is controlled
by the I/O option OUTPUT.
File Contents

Result

Description

Acceleration

Acceleration results from multi-body dynamics analyses. Output is


controlled by the I/O option ACCELERATION.

File Format
Time"X Trans"Y Trans"Z Trans
Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _mbd.mvw HyperView script file automatically creates plots for the results contained
in this file.

2326 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_s#_a.trn file
The _s#_a.trn file is an OptiStruct ASCII format results file.
File Creation
This file is only created for transient response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Acceleration

Acceleration results from frequency response analyses. Output is


controlled by the I/O option ACCELERATION.

File Format
Time"X Trans"Y Trans"Z Trans

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _tran.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2327


Proprietary Information of Altair Engineering

_s#_d.#.frf file
The _s#_d.#.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response optimization. Output is controlled by the I/O
option DISPLACEMENT and OUTPUT,HGFREQ.
File Contents
This file contains the displacement results from frequency response optimization.
File Format
If the real and imaginary format was selected on the DISPLACEMENT card, the file starts with
the following header:
Frequency"REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans
If the phase and magnitude format was selected on the DISPLACEMENT card, the file starts
with the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case, the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle


in the x-direction component.

X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

2328 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The first # in the file name is the user-defined subcase ID.

2.

The second # in the file name is the iteration number.

3.

The _freq.#.mvw HyperView script file automatically creates plots for the results
contained in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2329


Proprietary Information of Altair Engineering

_s#_d.frf file
The _s#_d.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Displacement

Displacement results from frequency response analyses. Output is


controlled by the I/O option DISPLACEMENT.

File Format
If the real and imaginary format was selected on the DISPLACEMENT card, the file starts with
the following header:
Frequency"REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans

If the phase and magnitude format was selected on the DISPLACEMENT card, the file starts
with the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case, the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle

2330 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

in the x-direction component.


X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _freq.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2331


Proprietary Information of Altair Engineering

_s#_d.mbd file
The _s#_d.mbd file is an OptiStruct ASCII format results file.
File Creation
This file is only created for Multi-Body Dynamics subcases. Creation of this file is controlled
by the I/O option OUTPUT.
File Contents

Result

Description

Displacement

Displacement results from multi-body dynamics analyses. Output is


controlled by the I/O option DISPLACEMENT.

File Format
Time"X Trans"Y Trans"Z Trans
Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _mbd.mvw HyperView script file automatically creates plots for the results contained
in this file.

2332 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_s#_d.trn file
The _s#_d.trn file is an OptiStruct ASCII format results file.
File Creation
This file is only created for transient response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Displacement

Displacement results from frequency response analyses. Output is


controlled by the I/O option DISPLACEMENT.

File Format
Time"X Trans"Y Trans"Z Trans

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _tran.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2333


Proprietary Information of Altair Engineering

_s#_v.#.frf file
The _s#_v.#.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response optimization. Output is controlled by the I/O
option VELOCITY and OUTPUT,HGFREQ.
File Contents
This file contains the velocity results from frequency response optimization.
File Format
If the real and imaginary format was selected on the VELOCITY card, the file starts with the
following header:
Frequency "REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans
If the phase and magnitude format was selected on the DISPLACEMENT card, the file starts
with the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case, the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle


in the x-direction component.

X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

2334 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The first # in the file name is the user-defined subcase ID.

2.

The second # in the file name is the iteration number.

3.

The _freq.#.mvw HyperView script file automatically creates plots for the results
contained in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2335


Proprietary Information of Altair Engineering

_s#_v.frf file
The _s#_v.frf file is an OptiStruct ASCII format results file.
File Creation
This file is only created for frequency response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Velocity

Velocity results from frequency response analyses. Output is controlled


by the I/O option VELOCITY.

File Format
If the real and imaginary format was selected on the VELOCITY card, the file starts with the
following header:
Frequency"REA | X Trans"IMA | X Trans"REA | Y Trans"IMA | Y Trans"REA | Z Trans"IMA | Z
Trans
If the phase and magnitude format was selected on the VELOCITY card, the file starts with
the following header:
Frequency"PHA | X Trans"MAG | X Trans"PHA | Y Trans"MAG | Y Trans"PHA | Z Trans"MAG |
Z Trans
In either case, the results are grouped by node with results for different nodes separated by a
blank line. The format of each line after the header is as follows:
Frequency

X-rl/ph

X-im/mag

Y-rl/ph

Y-im/mag

Z-rl/ph

Z-im/mag

where:
Frequency

is the frequency at which results are calculated.

X-rl/ph

is either the real component in the x-direction or the phase angle


in the x-direction component.

2336 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

X-im/mag

is either the imaginary component in the x-direction or the


magnitude in the x-direction component.

Y-rl/ph

is either the real component in the y-direction or the phase angle


in the y-direction component.

Y-im/mag

is either the imaginary component in the y-direction or the


magnitude in the y-direction component.

Z-rl/ph

is either the real component in the z-direction or the phase angle


in the z-direction component.

Z-im/mag

is either the imaginary component in the z-direction or the


magnitude in the z-direction component.

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _freq.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2337


Proprietary Information of Altair Engineering

_s#_v.mbd file
The _s#_v.mbd file is an OptiStruct ASCII format results file.
File Creation
This file is only created for multi-body dynamics subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Velocity

Velocity results from multi-body dynamics analyses. Output is controlled


by the I/O option VELOCITY.

File Format
Time"X Trans"Y Trans"Z Trans
Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _mbd.mvw HyperView script file automatically creates plots for the results contained
in this file.

2338 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_s#_v.trn file
The _s#_v.trn file is an OptiStruct ASCII format results file.
File Creation
This file is only created for transient response subcases. Creation of this file is controlled by
the I/O option OUTPUT.
File Contents

Result

Description

Velocity

Velocity results from frequency response analyses. Output is


controlled by the I/O option VELOCITY.

File Format
Time"X Trans"Y Trans"Z Trans

Comments
1.

The # in the file name is the user-defined subcase ID from which these results are
obtained.

2.

The _tran.mvw HyperView script file automatically creates plots for the results contained
in this file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2339


Proprietary Information of Altair Engineering

_sens.#.mvw file
The _sens.#.mvw file is a HyperView session file.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O option OUTPUT.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates a histogram for each of the results contained in
the .#.sens file. The plots are grouped so that design variable sensitivities for different
responses are given on separate pages.
Comments
1.

The # in the file name is the iteration number.

2340 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_shuffling.#.fem file
The _shuffling.#.fem file is an ASCII format file.
File Creation
This file is created when OUTPUT, SZTOSH (sizing to shuffling) is requested during the plybased sizing optimization phase.
File Contents
This file is a ply-based stacking optimization input deck. It contains the updated PLY and
STACK cards describing the stacking model, as well as a DSHUFFLE card defining shuffling
design variables.
Comments
1.

The # in the file name is the number of the last iteration.

Altair Engineering

OptiStruct 13.0 Reference Guide 2341


Proprietary Information of Altair Engineering

_sizing.#.fem file
The _sizing.#.fem file is an ASCII format file.
File Creation
This file is created when OUTPUT, FSTOSZ (free-sizing to sizing) is requested during the freesizing optimization phase.
File Contents
This file is a ply-based sizing optimization input deck. It contains PCOMPP, STACK, PLY, and
SET cards describing the ply-based composite model, as well as DCOMP, DESVAR, and DVPREL
cards defining the optimization data.
Comments
1.

The # in the file name is the number of the last iteration.

2342 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

_topol.h3d file
The _topol.h3d file is a compressed binary file containing both model and result data. It can
be used to post-process topology (density) sensitivity in HyperView.
File Creation
This file is created when an optimization is performed. Creation of this file is controlled by the
I/O option OUTPUT.
File Contents
The _topol.h3d file contains node and element definitions in addition to the following results:

Result

Description

Sensitivity Sensitivity of response vs. element density from topology optimization.


Output is controlled by the I/O option OUTPUT.

Comments
1.

The # in the file name is the iteration number.

Altair Engineering

OptiStruct 13.0 Reference Guide 2343


Proprietary Information of Altair Engineering

_tran.mvw file
The _tran.mvw file is a HyperView session file.
File Creation
This file is only created when a transient response analysis is performed. Creation of this file
is controlled by the I/O option OUTPUT.
File Contents
This file is a HyperView session file and may be opened from the File menu in HyperView or
HyperGraph. The file automatically creates plots for each of the results contained in the files
_s#_a.trn, _s#_d.trn, and _s#_v.trn.

2344 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

<BODY_NAME>.h3d file
The <BODY_NAME>.h3d file is a compressed binary file from a multi-body dynamics analysis
that uses flexible bodies defined through a PFBODY bulk data entry.
File Creation
This file is created when a multi-body dynamics subcase is executed. One file for each
PFBODY entry is generated. BODY_NAME is taken directly from PFBODY, BODY_NAME. If no
BODY_NAME is given, the default is OUTFILE_body_<BID>.h3d. By default, the flexible body is
only generated once; and if a file already exists in the execution directory, the flexible body
generation is not repeated. The default can be changed by the parameter PARAM, FLEXH3D.
File Contents
This file contains the modal representation of the flexible body for direct use in the multi-body
dynamics solution sequence or in MotionSolve. It is generated using a Component Mode
Synthesis. Each flexible body is written to a separate file.

Altair Engineering

OptiStruct 13.0 Reference Guide 2345


Proprietary Information of Altair Engineering

Results Output by OptiStruct


The tables in this section summarize the results output for different analysis types. They
show the formats available for each result and the I/O option entry that controls the output
of the result.
The columns in the tables represent the major output streams:
H3D

Hyper3D format (.h3d file)

HM

HyperMesh format (.res file)

OP2

Nastran Output2 format (.op2 file)

PCH

Nastran Punch format (.pch file)

OPT

OptiStruct ASCII format (multiple files)

PAT

Patran and Alternative-Patran formats (multiple files)

H3D (MBD)

Hyper3D format for body results (_mbd.h3d)

MRF

Multi-body results file (_mbd.mrf)

Results for Linear Static Analysis and Nonlinear Quasi-Static Analysis

H3D

HM

OP2

PCH

OPT

PAT

Nodal Displacements

Controlling
I/O Option
DISPLACEMENT

Element Strain Energy

ESE

Element Stresses *

STRESS

Element Strains *

STRAIN

Ply Stresses

CSTRESS

Composite Failure
Indices

CSTRESS

Ply Strains

CSTRAIN

2346 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

H3D

HM

OP2

PCH

OPT

PAT

Controlling
I/O Option

Element Forces

FORCE

Grid Point Stresses

GPSTRESS

SPC Forces

SPCFORCE

MPC Forces

MPCFORCE

Grid Point Forces

GPFORCE

Applied Loads

OLOAD

Results for Linear Steady-state Heat Transfer Analysis


H3D

OP2

PCH

Controlling I/O Option

Nodal Temperatures

THERMAL

Element Fluxes and


Gradients

FLUX

Results for Linear Transient Heat Transfer Analysis


H3D
Nodal Temperatures

Altair Engineering

OP2

PCH

Controlling I/O Option


THERMAL

OptiStruct 13.0 Reference Guide 2347


Proprietary Information of Altair Engineering

Results for Normal Modes Analysis

H3D

HM

OP2

PCH

OPT

PAT

Eigenvectors

Controlling
I/O Option
DISPLACEMENT

Element Kinetic Energy

EKE

Element Strain Energy

ESE

Grid Point Energy

GPKE

Grid Point Stress

GPSTRESS

Element Stresses *

STRESS

SPC Forces

SPCFORCE

MPC Forces

MPCFORCE

Grid Point Forces

GPFORCE

Nodal Pressures (Fluid)

PRESSURE

Ply Stresses

CSTRESS

Ply Strains

CSTRAIN

Results for Complex Eigenvalue Analysis

H3D

OP2

Eigenvectors

PCH

Controlling
I/O Option
DISPLACEMENT

2348 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Results for Linear Buckling Analysis

H3D

HM

OP2

PCH

OPT

Eigenvectors

Controlling
I/O Option
DISPLACEMENT

Results for Frequency Response Analysis

H3D HM OP2 PCH OPT

XYPUNCH

Nodal Displacements

Controlling
I/O Option
DISPLACEMENT

Modal Participation
Displacements

SDISPLACEMENT

Element Energy Loss Per


Cycle

EDE

Element Kinetic Energy

EKE

Element Strain Energy

ESE

Nodal Velocities

VELOCITY

Modal Participation Velocities

SVELOCITY

Nodal Accelerations

ACCELERATION

Modal Participation
Accelerations

SACCELERATION

Element Stresses *

STRESS

Element Strains *

STRAIN

Altair Engineering

OptiStruct 13.0 Reference Guide 2349


Proprietary Information of Altair Engineering

H3D HM OP2 PCH OPT

Controlling
I/O Option

XYPUNCH

Element Forces

FORCE

SPC Forces

SPCFORCE

MPC Forces

MPCFORCE

Grid Point Forces

GPFORCE

Power Flow Field

POWERFLOW

Ply Stresses

CSTRESS

Ply Strains

CSTRAIN

Sound Power

SPOWER

Sound Intensity

SINTENS

Sound Pressure Level

SPL

Applied Load Vectors

OLOAD

Results for Coupled Frequency Response Analysis of Fluid-structural Models (Acoustic


Analysis)
H3D OP2 PCH
Nodal Displacements

Controlling I/O Option


DISPLACEMENT

Modal Participation
Displacements

SDISPLACEMENT

Nodal Velocities

VELOCITY

2350 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

H3D OP2 PCH


Modal Participation Velocities

Controlling I/O Option


SVELOCITY

Nodal Accelerations

ACCELERATION

Modal Participation
Accelerations

SACCELERATION

Nodal Pressures (Fluid)

PRESSURE

Element Stresses *

STRESS

Element Strains *

STRAIN

Element Forces

FORCE

SPC Forces

SPCFORCE

MPC Forces

MPCFORCE

Grid Point Forces

GPFORCE

Power Flow Field

POWERFLOW

Ply Stress

CSTRESS

Ply Strain

CSTRAIN

Results for Transient Analysis


H3D

Nodal Displacements

Altair Engineering

HM

OP2 PCH OPTI

Controlling
I/O Option
DISPLACEMENT

OptiStruct 13.0 Reference Guide 2351


Proprietary Information of Altair Engineering

H3D

HM

OP2 PCH OPTI

Modal Participation
Displacements

Controlling
I/O Option
SDISPLACEMENT

Nodal Velocities

VELOCITY

Modal Participation Velocities

SVELOCITY

Nodal Accelerations

ACCELERATION

Modal Participation
Accelerations

SACCELERATION

Element Stresses *

STRESS

Element Strains *

STRAIN

Element Forces

FORCE

MPC Forces

MPCFORCE

Ply Stresses

CSTRESS

Ply Strains

CSTRAIN

Composite Failure Indices

CSTRESS

Applied Load Vectors

OLOAD

Results for Random Response Analysis (PSDF Request)

XYPUNCH

XYPLOT
PUNCH
(HyperGraph)

OP2

H3D

DISP / VELO / ACCE

2352 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

XYPUNCH

XYPLOT
PUNCH
(HyperGraph)

OP2

H3D

Shell Stress
Shell Strain
Solid Stress
Solid Strain
CBUSH Force
CELAS / CDAMP / CVISC
Forces

Results for Random Response Analysis


OP2 PCH

H3D

Controlling I/O Option

Displacement PSD and


RMS

DISP, XYPEAK, XYPLOT, XYPUNCH

Velocity PSD and RMS

VELO, XYPEAK, XYPLOT, XYPUNCH

Acceleration PSD and


RMS

ACCEL, XYPEAK, XYPLOT, XYPUNCH

PSD Element Force and


RMS

FORCE, XYPEAK, XYPLOT, XYPUNCH

PSD Element Stress

STRESS, XYPEAK, XYPLOT, XYPUNCH

PSD Element Strain

STRAIN, XYPEAK, XYPLOT, XYPUNCH

RMS Element Stress

STRESS

Altair Engineering

OptiStruct 13.0 Reference Guide 2353


Proprietary Information of Altair Engineering

STRAIN

RMS Element Strain

Results for Multi-body Dynamics Analysis


H3D

HM

OP2

H3D
(MBD)

MRF

Nodal Displacements

Controlling
I/O Option
DISPLACEMENT

Nodal Velocities

VELOCITY

Nodal Accelerations

ACCELERATION

Element Stresses *

STRESS

Element Strains *

STRAIN

Body time history


System time history
Marker time history

REQUEST

Results for Fatigue Analysis


H3D

Controlling I/O Option

Element Life

LIFE

Element Damage

DAMAGE

2354 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Results for Geometric Nonlinear Analysis (ANALYSIS=NLGEOM, IMPDYN or EXPDYN)


Controlling
I/O Option

Controlling
I/O Option
(Block Format)

Nodal Displacements

DISPLACEMENT

/ANIM/VECT/DISP
/ANIM/VECT/DROT

Nodal Velocities

VELOCITY

/ANIM/VECT/VEL

Nodal Accelerations

ACCELERATION

/ANIM/VECT/ACC

STRESS

/ANIM/BRICK/TENS/
STRESS
/ANIM/SHELL/TENS/
STRESS/UPPER
/ANIM/SHELL/TENS/
STRESS/LOWER
/ANIM/BEAM/VONM
/ANIM/TRUSS/SIGX

STRAIN

/ANIM/BRICK/TENS/
STRAIN
/ANIM/SHELL/TENS/
STRAIN/UPPER
/ANIM/SHELL/TENS/
STRAIN/LOWER

Ply Stresses

CSTRESS

/ANIM/SHELL/TENS/
STRESS/N
/ANIM/SHELL/TENS/
STRESS/ALL

Ply Strains

CSTRAIN

/ANIM/SHELL/TENS/
STRAIN/ALL

Composite Failure
Indices

CSTRESS

N/A

Element Forces

FORCE

/ANIM/Eltyp/FORC

Grid Point Stresses

GPSTRESS

/ANIM/GPS1/TENS
/ANIM/GPS1/SHELL/

H3D OP2 PCH

Element Stresses*

Element Strains*

Altair Engineering

OptiStruct 13.0 Reference Guide 2355


Proprietary Information of Altair Engineering

Controlling
I/O Option

H3D OP2 PCH

Controlling
I/O Option
(Block Format)
UPPER
/ANIM/GPS1/SHELL/
LOWER

SPC Forces

SPCFORCE

/ANIM/VECT/FREAC
/ANIM/VECT/MREAC

MPC Forces

MPCFORCE

/ANIM/VECT/FINT

Applied Loads

OLOAD

/ANIM/VECT/FEXT

Plastic Strain

STRAIN
(PLASTIC)

/ANIM/ELEM/EPSP
/ANIM/SHELL/EPSP/
UPPER
/ANIM/SHELL/EPSP/
LOWER

Contact Force and


Pressure

CONTF

/ANIM/VECT/CONT
/ANIM/VECT/PCONT

Element Thinning and


Thickness

THIN

/ANIM/ELEM/THIC
/ANIM/SHELL/THIN

Element Energy

ENERGY

/ANIM/ELEM/ENER
/ANIM/ELEM/HOURG

Optimization Results

H3D

HM

OP2

PCH

OPT

PAT

Element Density

Controlling
I/O Option
DENSITY

Element Thickness

THICKNESS

2356 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

H3D

HM

OP2

PCH

OPT

PAT

Controlling
I/O Option

Ply Thickness

THICKNESS

% Thickness

THICKNESS

Shape

SHAPE

* The element stress and strain results written to the various output streams are not
always the same. Refer to the following pages for more details on the stress results
available in the different output streams:
Strain Results Written in HyperView .h3d Format
Strain Results Written in Nastran .op2 and .pch Formats
Strain Results Written in HyperMesh .res Format
Stress Results Written in HyperView .h3d Format
Stress Results Written in Nastran .op2 and .pch Format
Stress Results Written in HyperMesh .res Format

Altair Engineering

OptiStruct 13.0 Reference Guide 2357


Proprietary Information of Altair Engineering

Strain Results Written in HyperView .h3d Format


1D Elements
ALL, DIRECT and TENSOR options
Von Mises Strain
CELAS Strain
CROD Axial Strain
CBAR Longitudinal Strain SAC
CBAR Longitudinal Strain SAD
CBAR Longitudinal Strain SAE
CBAR Longitudinal Strain SAF
CBAR Longitudinal Strain SAMIN
CBAR Longitudinal Strain SAMAX
CBAR Longitudinal Strain SBC
CBAR Longitudinal Strain SBD
CBAR Longitudinal Strain SBE
CBAR Longitudinal Strain SBF
CBAR Longitudinal Strain SBMIN
CBAR Longitudinal Strain SBMAX
CWELD Axial Strain
CWELD Maximum Strain A
CWELD Minimum Strain A
CWELD Maximum Strain B
CWELD Minimum Strain B
CWELD Maximum Shear Strain
VON and PRINC options
Von Mises Strain
1D Elements (CBAR/CBEAM via PBARL/PBEAML)
The following strain results are output for CBAR/CBEAM elements defined via PBARL/PBEAML
property entries. The Result type: HyperView is CBAR/CBEAM Strains (<TYPE>), where the
<TYPE> entry is based on the selected cross-section (TYPE/NAME field) on the PBARL/PBEAML
entries. The element strain results can be reviewed for each cross-section type,
corresponding evaluation point, at element ends (A or B). The maximum normal/shear/von
Mises strains can also be reviewed.
Syntax
-

CBAR/CBEAM Strains (<Type>)


<Strain Result Output> <evaluation point> (A/B)

Where,
<Type> = BAR, BOX, BOX1, CHAN, CHAN1, CHAN2, CROSS, H, HAT, I, I1, ROD, T, T1,
T2, TUBE, Z.
<Strain Result Output> = normal, shear, and von Mises
<evaluation point> = evaluation point of the element

2358 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Examples
-

CBAR/CBEAM Strains(BAR)
Normal S1N(A)
Normal S1N(B)
Shear S4S(A)
Shear S4S(B)
von Mises S8V(A)
von Mises S8V(B)

Example descriptions
Normal S3N(B): normal strain at the 3rd evaluation point of the beam element (end B);
Shear S6S(A): shear strain at the 6th evaluation point of the beam element (end A);
von Mises S5V(B): von Mises strain at the 5th evaluation point of the beam element (end
B).
Review evaluation points via: DRESP1 - Static Strain Item Codes for Bar Elements using
PBARL, PBEAML Properties
The von Mises strains for all CBEAM/CBAR elements with PBARL/PBEAML properties at the same
time can be output using the Result type: CBAR/CBEAM vonMises Strains.
Syntax
-

CBAR/CBEAM vonMises Strains


<Strain Result Output>

Where,
<Strain Result Output> = Von Mises

2D Elements
ALL and TENSOR options
Results are calculated by HyperView.

DIRECT option
Von Mises Strain
Maximum Principal Strain
Von Mises Strain (Z1)
Von Mises Strain (Z2)
Von Mises Strain (mid)
P1 (major) Strain (Z1)
P1 (major) Strain (Z2)
P1 (major) Strain (mid)

Altair Engineering

OptiStruct 13.0 Reference Guide 2359


Proprietary Information of Altair Engineering

P3 (minor) Strain (Z1)


P3 (minor) Strain (Z2)
P3 (minor) Strain (mid)
Normal X Strain (Z1)
Normal X Strain (Z2)
Normal X Strain (mid)
Normal Y Strain (Z1)
Normal Y Strain (Z2)
Normal Y Strain (mid)
Shear XY Strain (Z1)
Shear XY Strain (Z2)
Shear XY Strain (mid)
Principal Strain Angle (Z1)
Principal Strain Angle (Z2)
Principal Strain Angle (mid)

VON option
Von Mises Strain - This is equal to max[Von Mises Strain (Z1), Von Mises Strain
(Z2)]
PRINC option
Von Mises Strain
Maximum Principal Strain

3D Elements
ALL and TENSOR options
Results are calculated by HyperView.

DIRECT option
Von Mises Strain
Signed Von Mises Strain
P1 (major) Strain (solid)
P2 (mid) Strain (solid)
P3 (minor) Strain (solid)
Normal X Strain (solid)
Normal Y Strain (solid)
Normal Z Strain (solid)
Shear XY Strain (solid)
Shear YZ Strain (solid)
Shear XZ Strain (solid)
VON option
Von Mises Strain
PRINC option

2360 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Von Mises Strain


Maximum Principal Strain
Comments
1.

In the TENSOR mode, pass tensor components to HyperView which then calculates derived
results on-the-fly.

2.

For frequency response loadcases, only the TENSOR mode is available.

Altair Engineering

OptiStruct 13.0 Reference Guide 2361


Proprietary Information of Altair Engineering

Strain Results Written in Nastran .op2 and .pch Formats


Static, Transient and Multi-body Loadcases
1D elements
CROD Axial Strain
CELAS Strain
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM

SA1
SA2
SA3
SA4
Axial
SA-maximum
SA-minimum
SB1
SB2
SB3
SB4
SB-maximum
SB-minimum
Long Strain at Point
Long Strain at Point
Long Strain at Point
Long Strain at Point
Maximum Strain1
Minimum Strain1
Long Strain at Point
Long Strain at Point
Long Strain at Point
Long Strain at Point
Maximum Strain2
Minimum Strain2

C1
D1
E1
F1

C2
D2
E2
F2

2D elements
Fibre Distance (Z1)
Normal XX Strain (Z1)
Normal YY Strain (Z1)
Shear XY Strain (Z1)
Principal Strain Angle (Z1)
Major Principal Strain (Z1)
Minor Principal Strain (Z1)
Von Mises Strain (Z1)
Fibre Distance (Z2)
Normal XX Strain (Z2)
Normal YY Strain (Z2)
Shear XY Strain (Z2)

2362 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Principal Strain Angle (Z2)


Major Principal Strain (Z2)
Minor Principal Strain (Z2)
Von Mises Strain (Z2)
3D elements
Normal XX Strain
Shear XY Strain
Major Principal Strain
Major Principal X Cosine
Mid Principal X Cosine
Minor Principal X Cosine
Mean Strain
Von Mises Strain
Normal YY Strain
Shear YZ Strain
Mid Principal Strain
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine
Normal ZZ Strain
Shear XZ Strain
Minor principal Strain
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine

Eigenvalue Loadcases
1D elements
None.
2D elements
Fibre Distance (Z1)
Normal XX Strain (Z1)
Normal YY Strain (Z1)
Shear XY Strain (Z1)
Principal Strain Angle
Major Principal Strain
Minor Principal Strain
Von Mises Strain (Z1)
Fibre Distance (Z2)
Normal XX Strain (Z2)
Normal YY Strain (Z2)
Shear XY Strain (Z2)
Principal Strain Angle
Major Principal Strain
Minor Principal Strain

Altair Engineering

(Z1)
(Z1)
(Z1)

(Z2)
(Z2)
(Z2)

OptiStruct 13.0 Reference Guide 2363


Proprietary Information of Altair Engineering

Von Mises Strain (Z2)


3D elements
Normal XX Strain
Shear XY Strain
Major Principal Strain
Major Principal X Cosine
Mid Principal X Cosine
Minor Principal X Cosine
Mean Strain
Von Mises Strain
Normal YY Strain
Shear YZ Strain
Mid Principal Strain
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine
Normal ZZ Strain
Shear XZ Strain
Minor principal Strain
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine

Frequency Response Loadcases


1D elements
CROD Axial Strain
CELAS Strain
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBEAM
CBEAM
CBEAM
CBEAM

SA1
SA2
SA3
SA4
Axial
SA-maximum
SA-minimum
SB1
SB2
SB3
SB4
SB-maximum
SB-minimum
Long
Long
Long
Long

Strain
Strain
Strain
Strain

at
at
at
at

Point
Point
Point
Point

C1
D1
E1
F1

2364 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM

Maximum Strain1
Minimum Strain1
Long Strain at Point
Long Strain at Point
Long Strain at Point
Long Strain at Point
Maximum Strain2
Minimum Strain2

2D elements
Fibre Distance (Z1)
Normal XX Strain (real)
Normal XX Strain (imag)
Normal YY Strain (real)
Normal YY Strain (imag)
Shear XY Strain (real)
Shear XY Strain (imag)
Fibre Distance (Z2)
Normal XX Strain (real)
Normal XX Strain (imag)
Normal YY Strain (real)
Normal YY Strain (imag)
Shear XY Strain (real)
Shear XY Strain (imag)
3D elements
Normal XX Strain
Normal YY Strain
Normal ZZ Strain
Shear XY Strain
Shear YZ Strain
Shear XZ Strain
Normal XX Strain
Normal YY Strain
Normal ZZ Strain
Shear XY Strain
Shear YZ Strain
Shear XZ Strain

C2
D2
E2
F2

(Z1)
(Z1)
(Z1)
(Z1)
(Z1)
(Z1)
(Z2)
(Z2)
(Z2)
(Z2)
(Z2)
(Z2)

(real)
(real)
(real)
(real)
(real)
(real)
(imag)
(imag)
(imag)
(imag)
(imag)
(imag)

Comments
1.

The order above reflects the contents of the OP2 file, but post-processors such as
HyperView may display results in a different manner.

Altair Engineering

OptiStruct 13.0 Reference Guide 2365


Proprietary Information of Altair Engineering

Strain Results Written in HyperMesh .res Format


Static, Eigenvalue, Transient and Multi-body Loadcases
ALL, DIRECT and TENSOR options
Von Mises Strain
Maximum Principal Strain
Von Mises Strain (Z1)
Von Mises Strain (Z2)
Von Mises Strain (mid)
P1 (major) Strain (Z1)
P1 (major) Strain (Z2)
P1 (major) Strain (mid)
P1 (major) Strain (max)
P3 (minor) Strain (Z1)
P3 (minor) Strain (Z2)
P3 (minor) Strain (mid)
P3 (minor) Strain (min)
Normal X Strain (Z1)
Normal X Strain (Z2)
Normal X Strain (mid)
Normal Y Strain (Z1)
Normal Y Strain (Z2)
Normal Y Strain (mid)
Shear XY Strain (Z1)
Shear XY Strain (Z2)
Shear XY Strain (mid)
Principal Strain Angle (Z1)
Principal Strain Angle (Z2)
Principal Strain Angle (mid)
Signed Von Mises Strain (solid)
P1 (major) Strain (solid)
P2 ( mid ) Strain (solid)
P3 (minor) Strain (solid)
Normal X Strain (solid)
Normal Y Strain (solid)
Normal Z Strain (solid)
Shear XY Strain (solid)
Shear YZ Strain (solid)
Shear XZ Strain (solid)
VON option
Von Mises Strain
PRINC option
Von Mises Strain
Maximum Principal Strain

2366 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Frequency Response Loadcases


Normal X
Normal X
Normal Y
Normal Y
Shear XY
Shear XY
Normal X
Normal Y
Normal Z
Shear XY
Shear YZ
Shear XZ

Strain
Strain
Strain
Strain
Strain
Strain
Strain
Strain
Strain
Strain
Strain
Strain

(Z1) (comp)
(Z2) (comp)
(Z1) (comp)
(Z2) (comp)
(Z1) (comp)
(Z2) (comp)
(solid) (comp)
(solid) (comp)
(solid) (comp)
(solid) (comp)
(solid) (comp)
(solid) (comp)

Comments
1. "von Mises Strain" and "Maximum Principal Strain" apply to 1D, 2D, and 3D elements
simultaneously. Other results apply to 2D or 3D elements exclusively. There are no
specific results for 1D elements.
2. For frequency response loadcases, (comp) may be replaced by (real) (imag) (magn) and/or
(phas), depending on the complex format request.
3. "Maximum Principal Strain" is the maximum absolute principal strain:
max(abs(P1(Z1)),abs(P1(Z2)),abs(P3(Z1)),abs(P3(Z2)))
max(abs(P1),abs(P2),abs(P3))

for shells.
for solids.

4. "P1 (major) Strain (max)" is the maximum major principal strain:


max(P1(Z1),P1(Z2)).
5. "P3 (minor) Strain (min)" is the minimum minor principal strain:
min(P3(Z1),P3(Z2)).
6. "Signed von Mises Strain" is the von Mises strain with traction/compression sign:
sign(P1+P2+P3) * VonMises.

Altair Engineering

OptiStruct 13.0 Reference Guide 2367


Proprietary Information of Altair Engineering

Stress Results Written in HyperView .h3d Format


1D Elements
ALL, DIRECT and TENSOR options
Von Mises Stress
CELAS Stress
CROD Axial Stress
CBAR Longitudinal Stress SAC
CBAR Longitudinal Stress SAD
CBAR Longitudinal Stress SAE
CBAR Longitudinal Stress SAF
CBAR Longitudinal Stress SAMIN
CBAR Longitudinal Stress SAMAX
CBAR Longitudinal Stress SBC
CBAR Longitudinal Stress SBD
CBAR Longitudinal Stress SBE
CBAR Longitudinal Stress SBF
CBAR Longitudinal Stress SBMIN
CBAR Longitudinal Stress SBMAX
CWELD Axial Stress
CWELD Maximum Stress A
CWELD Minimum Stress A
CWELD Maximum Stress B
CWELD Minimum Stress B
CWELD Maximum Shear Stress
CWELD Bearing Stress
VON and PRINC options
Von Mises Stress
1D Elements (CBAR/CBEAM via PBARL/PBEAML)
The following stress results are output for CBAR/CBEAM elements defined via PBARL/PBEAML
property entries. The Result type: HyperView is CBAR/CBEAM Stresses (<TYPE>), where the
<TYPE> entry is based on the selected cross-section (TYPE/NAME field) on the PBARL/PBEAML
entries. The element stress results can be reviewed for each cross-section type,
corresponding evaluation point, at element ends (A or B). The maximum normal/shear/von
Mises stresses can also be reviewed.
Syntax
-

CBAR/CBEAM Stresses (<Type>)


<Stress Result Output> <evaluation point> (A/B)

Where,
<Type> = BAR, BOX, BOX1, CHAN, CHAN1, CHAN2, CROSS, H, HAT, I, I1, ROD, T, T1,
T2, TUBE, Z.

2368 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

<Stress Result Output> = normal, shear, and von Mises


<evaluation point> = evaluation point of the element
Examples
-

CBAR/CBEAM Stresses(BAR)
Normal S1N(A)
Normal S1N(B)
Shear S4S(A)
Shear S4S(B)
von Mises S8V(A)
von Mises S8V(B)

Example descriptions
Normal S3N(B): normal stress at the 3rd evaluation point of the beam element (end B);
Shear S6S(A): shear stress at the 6th evaluation point of the beam element (end A);
von Mises S5V(B): von Mises stress at the 5th evaluation point of the beam element (end
B).
Review evaluation points via: DRESP1 - Static Stress Item Codes for Bar Elements using
PBARL, PBEAML Properties
The von Mises stresses for all CBEAM/CBAR elements with PBARL/PBEAML properties at the
same time can be output using the Result type: CBAR/CBEAM vonMises Stresses.
Syntax
-

CBAR/CBEAM vonMises Stresses


<Stress Result Output>

Where,
<Stress Result Output> = Von Mises

2D Elements
ALL and TENSOR options
Results are calculated by HyperView.

DIRECT option
Von Mises Stress
Maximum Principal Stress
Von Mises Stress (Z1)
Von Mises Stress (Z2)

Altair Engineering

OptiStruct 13.0 Reference Guide 2369


Proprietary Information of Altair Engineering

Von Mises Stress (mid)


P1 (major) Stress (Z1)
P1 (major) Stress (Z2)
P1 (major) Stress (mid)
P3 (minor) Stress (Z1)
P3 (minor) Stress (Z2)
P3 (minor) Stress (mid)
Normal X Stress (Z1)
Normal X Stress (Z2)
Normal X Stress (mid)
Normal Y Stress (Z1)
Normal Y Stress (Z2)
Normal Y Stress (mid)
Shear XY Stress (Z1)
Shear XY Stress (Z2)
Shear XY Stress (mid)
Principal Stress Angle (Z1)
Principal Stress Angle (Z2)
Principal Stress Angle (mid)
VON option - This is equal to max[Von Mises Stress (Z1), Von Mises Stress (Z2)]
PRINC option
Von Mises Stress
Maximum Principal Stress

3D Elements
ALL and TENSOR options
Results are calculated by HyperView.

DIRECT option
Von Mises Stress
Signed Von Mises Stress
P1 (major) Stress (solid)
P2 (mid) Stress (solid)
P3 (minor) Stress (solid)
Normal X Stress (solid)
Normal Y Stress (solid)
Normal Z Stress (solid)
Shear XY Stress (solid)
Shear YZ Stress (solid)
Shear XZ Stress (solid)
VON option
Von Mises Stress

2370 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PRINC option
Von Mises Stress
Maximum Principal Stress
Comments
1.

In the TENSOR mode, pass tensor components to HyperView, which then calculates
derived results on-the-fly.

2.

For frequency response loadcases, only the TENSOR mode is available.

Altair Engineering

OptiStruct 13.0 Reference Guide 2371


Proprietary Information of Altair Engineering

Stress Results Written in Nastran .op2 and .pch Formats


Static, Transient and Multi-body Loadcases
1D elements
CROD Axial Stress
CELAS Stress
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM

SA1
SA2
SA3
SA4
Axial
SA-maximum
SA-minimum
SB1
SB2
SB3
SB4
SB-maximum
SB-minimum
Long Stress at Point
Long Stress at Point
Long Stress at Point
Long Stress at Point
Maximum Stress1
Minimum Stress1
Long Stress at Point
Long Stress at Point
Long Stress at Point
Long Stress at Point
Maximum Stress2

C1
D1
E1
F1

C2
D2
E2
F2

CBEAM Minimum Stress2

2D elements
Fibre Distance (Z1)
Normal XX Stress (Z1)
Normal YY Stress (Z1)
Shear XY Stress (Z1)
Principal Stress Angle (Z1)
Major Principal Stress (Z1)
Minor Principal Stress (Z1)
Von Mises Stress (Z1)
Fibre Distance (Z2)
Normal XX Stress (Z2)
Normal YY Stress (Z2)

2372 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Shear XY Stress (Z2)


Principal Stress Angle (Z2)
Major Principal Stress (Z2)
Minor Principal Stress (Z2)
Von Mises Stress (Z2)

3D elements
Normal XX Stress
Shear XY Stress
Major Principal Stress
Major Principal X Cosine
Mid Principal X Cosine
Minor Principal X Cosine
Mean Stress
Von Mises Stress
Normal YY Stress
Shear YZ Stress
Mid Principal Stress
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine
Normal ZZ Stress
Shear XZ Stress
Minor principal Stress
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine

Eigenvalue Loadcases
1D elements
None
2D elements
Fibre Distance (Z1)
Normal XX Stress (Z1)
Normal YY Stress (Z1)
Shear XY Stress (Z1)
Principal Stress Angle
Major Principal Stress
Minor Principal Stress
Von Mises Stress (Z1)
Fibre Distance (Z2)
Normal XX Stress (Z2)
Normal YY Stress (Z2)
Shear XY Stress (Z2)
Principal Stress Angle
Major Principal Stress
Minor Principal Stress

Altair Engineering

(Z1)
(Z1)
(Z1)

(Z2)
(Z2)
(Z2)

OptiStruct 13.0 Reference Guide 2373


Proprietary Information of Altair Engineering

Von Mises Stress (Z2)


3D elements
Normal XX Stress
Shear XY Stress
Major Principal Stress
Major Principal X Cosine
Mid Principal X Cosine
Minor Principal X Cosine
Mean Stress
Von Mises Stress
Normal YY Stress
Shear YZ Stress
Mid Principal Stress
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine
Normal ZZ Stress
Shear XZ Stress
Minor principal Stress
Major Principal Y Cosine
Mid Principal Y Cosine
Minor Principal Y Cosine

Frequency Response Loadcases


1D elements
CROD Axial Stress
CELAS Stress
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBAR
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM

SA1
SA2
SA3
SA4
Axial
SA-maximum
SA-minimum
SB1
SB2
SB3
SB4
SB-maximum
SB-minimum
Long Stress at Point
Long Stress at Point
Long Stress at Point
Long Stress at Point
Maximum Stress1
Minimum Stress1

C1
D1
E1
F1

2374 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

CBEAM
CBEAM
CBEAM
CBEAM
CBEAM
CBEAM

Long Stress at Point


Long Stress at Point
Long Stress at Point
Long Stress at Point
Maximum Stress2
Minimum Stress2

2D elements
Fibre Distance (Z1)
Normal XX Stress (real)
Normal XX Stress (imag)
Normal YY Stress (real)
Normal YY Stress (imag)
Shear XY Stress (real)
Shear XY Stress (imag)
Fibre Distance (Z2)
Normal XX Stress (real)
Normal XX Stress (imag)
Normal YY Stress (real)
Normal YY Stress (imag)
Shear XY Stress (real)
Shear XY Stress (imag)
3D elements
Normal XX Stress
Normal YY Stress
Normal ZZ Stress
Shear XY Stress
Shear YZ Stress
Shear XZ Stress
Normal XX Stress
Normal YY Stress
Normal ZZ Stress
Shear XY Stress
Shear YZ Stress
Shear XZ Stress

C2
D2
E2
F2

(Z1)
(Z1)
(Z1)
(Z1)
(Z1)
(Z1)
(Z2)
(Z2)
(Z2)
(Z2)
(Z2)
(Z2)

(real)
(real)
(real)
(real)
(real)
(real)
(imag)
(imag)
(imag)
(imag)
(imag)
(imag)

Comments
1.

The order above reflects the contents of the OP2 file, but post-processors such as
HyperView may display results in a different manner.

2.

For 2D elements, results are printed at the center of the element, followed by results at
each grid when corner stresses are requested.

3.

For 3D elements, results are printed at the center of the element, followed by results at
each grid when corner stresses are requested. In the OP2 format, regardless of the
corner stress request, results are printed at each grid by duplicating results at the
center.

Altair Engineering

OptiStruct 13.0 Reference Guide 2375


Proprietary Information of Altair Engineering

Stress Results Written in HyperMesh .res Format


Static, Eigenvalue, Transient and Multi-body Loadcases
ALL, DIRECT and TENSOR options
Von Mises Stress
Maximum Principal Stress
Von Mises Stress (Z1)
Von Mises Stress (Z2)
Von Mises Stress (mid)
P1 (major) Stress (Z1)
P1 (major) Stress (Z2)
P1 (major) Stress (mid)
P1 (major) Stress (max)
P3 (minor) Stress (Z1)
P3 (minor) Stress (Z2)
P3 (minor) Stress (mid)
P3 (minor) Stress (min)
Normal X Stress (Z1)
Normal X Stress (Z2)
Normal X Stress (mid)
Normal Y Stress (Z1)
Normal Y Stress (Z2)
Normal Y Stress (mid)
Shear XY Stress (Z1)
Shear XY Stress (Z2)
Shear XY Stress (mid)
Principal Stress Angle (Z1)
Principal Stress Angle (Z2)
Principal Stress Angle (mid)
Signed Von Mises Stress (solid)
P1 (major) Stress (solid)
P2 ( mid ) Stress (solid)
P3 (minor) Stress (solid)
Normal X Stress (solid)
Normal Y Stress (solid)
Normal Z Stress (solid)
Shear XY Stress (solid)
Shear YZ Stress (solid)
Shear XZ Stress (solid)
VON option
Von Mises Stress
PRINC option
Von Mises Stress
Maximum Principal Stress

2376 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Frequency response loadcases


Normal X Stress (Z1) (comp)
Normal X Stress (Z2) (comp)
Normal Y Stress (Z1) (comp)
Normal Y Stress (Z2) (comp)
Shear XY Stress (Z1) (comp)
Shear XY Stress (Z2) (comp)
Normal X Stress (solid) (comp)
Normal Y Stress (solid) (comp)
Normal Z Stress (solid) (comp)
Shear XY Stress (solid) (comp)
Shear YZ Stress (solid) (comp)
Shear XZ Stress (solid) (comp)
Comments
1. "von Mises Stress" and "Maximum Principal Stress" apply to 1D, 2D, and 3D elements
simultaneously. Other results apply to 2D or 3D elements exclusively. There are no
specific results for 1D elements.
2. For frequency response loadcases, (comp) may be replaced by (real) (imag) (magn) and/or
(phas), depending on the complex format request.
3. "Maximum Principal Stress" is the maximum absolute principal stress:
max(abs(P1(Z1)),abs(P1(Z2)),abs(P3(Z1)),abs(P3(Z2)))
for shells.
max(abs(P1),abs(P2),abs(P3))
for solids.
4. "P1 (major) Stress (max)" is the maximum major principal stress:
max(P1(Z1),P1(Z2)).
5. "P3 (minor) Stress (min)" is the minimum minor principal stress:
min(P3(Z1),P3(Z2)).
6. "Signed von Mises Stress" is the von Mises stress with traction/compression sign:
sign(P1+P2+P3) * VonMises.

Altair Engineering

OptiStruct 13.0 Reference Guide 2377


Proprietary Information of Altair Engineering

Legacy Data
Previous (OS3.5) Input Format
Setting Up Decks in OptiStruct 5.0 and higher with OptiStruct 3.5 Objectives and Constraints
Previously Supported Input

2378 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Previous (OS3.5) Input Format


OptiStruct will continue to support the old input format from version 3.5. The new
optimization capabilities will not be available if the old format is used for the set up of the
optimization problem, that is, if matfrac, mini, maxi, ubcon or lbcon are present.
This section is intended to be used for the purpose of debugging or re-running older decks.
OptiStruct Version 3.5 Parameters:
Checkerboard

0,1,2, or blank
(default = 0,
if card not in deck)
(Default = 1, if blank)

Controls checkerboarding. Use 0 for no


checkerboard control. Use 1 or blank for global
averaging over the entire design domain. This
option generally yields a large number of semidense elements around fully dense elements.
To reduce the number of semi-dense elements
in the solution, restart the final iteration with
checkerboard control off and run for 10-20
iterations. This may reintroduce some local
checkerboarding. This method is used with
plate/shell and solid design elements and is
highly recommended for tetra elements. Nodal
densities are output to the .res file if this
option is used. Use 2 for averaging at local
areas identified as checkerboarded. Since
averaging is only applied locally, a much smaller
number of semi-dense elements are found in the
final iteration compared to the global averaging
method. This method applies only to plate/shell
design elements. If used in models with solid
design elements, checkerboard control is not
applied to solid elements.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Discrete

<real>default = 1.0

Discreteness parameter. Influences the


tendency for elements to converge to a
material density of 0 or 1. Higher values
decrease the number of elements that remain
between 0 and 1. Recommended bounds are
0.0 and 2.0.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Dcomp

<integer>

Altair Engineering

Shell elements with PCOMP PID given on this


card will be placed in the topology design
domain. This card overrides declarations in the
bulk data deck.

OptiStruct 13.0 Reference Guide 2379


Proprietary Information of Altair Engineering

Dshell

<integer>no
def<real>def=0.0

Shell elements with PSHELL PID given in first


field of DSHELL card will be placed into the
topology design domain with T0 given in the
second field. This card overrides declarations in
the bulk data deck.

Dsolid

<integer>

Solid elements with PSOLID PID given on this


card will be placed into the topology design
domain. This card overrides declarations in bulk
data deck.

Matinit

<real>def. = 0.9 or
constraint val.

This card declares the initial material fraction.


For runs with mass as the objective, default is
0.9. For runs with constrained mass, default is
reset to constraint value.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Maxiter

<integer>default = 30 Maximum number of iterations. Sets an upper


limit on the number of iterations OptiStruct can
perform before completion. If maxiter = 0,
baseline analysis is conducted after initializing
material fractions of all design elements at the
matfrac value. If check is present, it overrides
maxiter = 0. If analysis is present, it overrides
maxiter = 0.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Mindens

<real>default = 0.01

Minimum element material density. Sets a lower


limit on the amount of material that can be
assigned to any design element. Extremely low
values for this parameter can result in an illconditioned stiffness matrix.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Minmember

<real>no
default<method>
default= 2

Specifies the minimum diameter of members


formed by OptiStruct. This also eliminates
checkerboard results. This command is used to
eliminate small members. Method is either 1 or
2. Method 2 is set as default since it achieves
more discrete solutions for most examples.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

2380 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Mmcheck

No input

The use of this card will ensure a checkerboard


free solution, although with the undesired side
effect of achieving a solution that involves a
large number of semi-dense elements, similar to
the result of using CHECKER=1. Therefore, use
this card only when it is necessary.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Objtol

<real>default = 0.005 Tolerance in objective function. If the


fractional change in objective function is below
this quantity for two consecutive iterations, the
optimization is considered converged and is
stopped.
OptiStruct errors out if this parameter is
repeated on DOPTPRM in the bulk data section.

Smooth

<real>default =
0.7071

Solution smoothness. Influences the step size


of the optimization iterations if the optimality
criteria method is used for topology
optimization. Changing this parameter generally
results in changes in the solution topology.
Larger values of this parameter create smoother
topologies for shell element models. Leave this
parameter at the default value, unless a
different solution topology is desired.
Recommended bounds are 0.5 and 0.9.

OptiStruct Version 3.5 Subcase Information:


lbcon

<real>
<string>
no
defaults

Mass

<real>

Altair Engineering

<integer*> Sets a lower bound constraint of value given


<integer*> in the first field of this card for the response
given in the second field of the card.
Supported responses are: volume, mass, disp,
comp, freq, wcomp, wfreq, and comb. Global
responses (volume, mass, wcomp, wfreq, and
comb) must be located outside of all subcase
declarations. Local responses (comp, freq,
and disp) must be located within a subcase
declaration. The third field is used for mode
number declarations for freq responses or grid
number declarations for disp responses. The
fourth field is used for grid component
declarations for disp responses.
Mass of total model. If present, the matfrac
parameter is not used. Input the total target

OptiStruct 13.0 Reference Guide 2381


Proprietary Information of Altair Engineering

no default

mass for the part and OptiStruct calculates


the material fraction automatically. If the
computed material fraction is below 0.0 or
above 1.0, OptiStruct returns an error. Not
available if using multiple material types in the
design domain.

Matfrac

<real>
default = 0.30
range = 0.0-1.0

Material fraction. Defines the amount of


material to be distributed within the design
domain as a fraction of the design domain.
For shell elements, design volume is equal to
(T - T0) * area. For solid elements, design
volume is equal to the sum of the volume of
the elements designated as design space.
The design volume multiplied by the material
fraction is the total amount of design material
available. Material fractions for all design
elements in the design space are initialized to
matfrac value.

maxi

<string>
<integer*> Sets objective function to maximize a
no default <integer*> response. Supported responses are: volume,
mass, disp, comp, freq, wcomp, wfreq, and
comb. Global responses (volume, mass,
wcomp, wfreq, and comb) must be located
outside of all subcase declarations. Local
responses (comp, freq, and disp) must be
located within a subcase declaration. The
second field is used for mode number
declarations for freq responses or grid number
declarations for disp responses. The fourth
field is used for grid component declarations
for disp responses.

mini

<string>
<integer*> Sets objective function to minimize a
no default <integer*> response. Supported responses are: volume,
mass, disp, comp, freq, wcomp, wfreq, and
comb. Global responses (volume, mass,
wcomp, wfreq, and comb) must be located
outside of all subcase declarations. Local
responses (comp, freq, and disp) must be
located within a subcase declaration. The
second field is used for mode number
declarations for freq responses or grid number
declarations for disp responses. The fourth
field is used for grid component declarations
for disp responses.

Primary

<integer

This card sets which mode of eigenvalue


solution is used to set material orientation

2382 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

or blank>
default=
lowest
mode with
highest
weight if
eigen.
Subcase
no default
if static.
ubcon

<real>
<string>
no
defaults

Altair Engineering

angles. Primary mode declaration only applies


to runs without static analyses and must be
placed in the subcase declaration. If the card
is placed in a static subcase, only that
subcase is used to determine material
orientation angle - no fields are necessary.

<integer*> Sets an upper bound constraint of value given


<integer*> in the first field of this card for the response
given in the second field of the card.
Supported responses are: volume, mass, disp,
comp, freq, wcomp, wfreq, and comb. Global
responses (volume, mass, wcomp, wfreq, and
comb) must be located outside of all subcase
declarations. Local responses (comp, freq,
and disp) must be located within a subcase
declaration. The third field is used for mode
number declarations for freq responses or grid
number declarations for disp responses. The
fourth field is used for grid component
declarations for disp responses.

OptiStruct 13.0 Reference Guide 2383


Proprietary Information of Altair Engineering

Setting Up Decks in OptiStruct 5.0 with OptiStruct 3.5


Objectives and Constraints
Setting up an optimization was simpler in OptiStruct 3.5, but it was also very limited. Starting
with OptiStruct 5.0, a lot more flexibility has been added to the way objectives and
constraints are set up, but the problem setup is more complex. Although versions of
OptiStruct (including and beyond 5.0) will execute OptiStruct 3.5 decks flawlessly, users are
urged to create decks using the new optimization format. This section demonstrates how
objectives and constraints in OptiStruct 3.5 (such as comp, freq, wcomp, wfreq, and comb)
can be set up in OptiStruct 5.0 and higher.
The new optimization capabilities of OptiStruct 5.0 and higher will not be available if the old
format is used for the setup of the optimization problem (if matfrac, mini, maxi, ubcon, or
lbcon are present in the setup).
Minimize Compliance for Constrained Mass Fraction
In OptiStruct 3.5, two cards were used to do this kind of optimization: mini, comp and ubcon,
0.3, volume.
The new setup is as follows: mini, comp is replaced by DESOBJ(MIN) = 1 and ubcon, 0.3,
volume is replaced by DESGLB = 101. Three cards (two DRESP1s and one DCONSTR) defining
the responses and constraint values referenced in the header are added after the BEGIN BULK
statement as shown below:
$
DESGLB = 101
$
SUBCASE 1
LOAD = 2
SPC = 1
DESOBJ(MIN) = 1
$
BEGIN BULK
$
DRESP1, 1, comp, COMP
DRESP1, 100, massf, MASSFRAC
DCONSTR, 101, 100, , 0.300
$
Minimize Mass for Constrained Displacement
The deck setup for this problem is similar to the previous one. Since the objective is global
(mass), the DESOBJ statement goes outside of the load case definition. The constraint on
displacement is only active for the first load case; thus a DESSUB statement is used within
that load case.
$
DESOBJ(MIN) = 1
$
SUBCASE 1
LOAD = 2
SPC = 1
DESSUB = 101

2384 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

$
BEGIN BULK
$
DRESP1, 1, weight, MASS
$
DRESP1, 100, disp, DISP, , , 7, , 1202
DCONSTR, 101, 100, , 1.4e-6
$

Minimize Weighted Compliance for Constrained Mass


OptiStruct provides the response type WCOMP, weighted
DRESP1 card. In addition, you need to define the weight
in the weighted compliance function. Note that both the
quantities (not specific to any single load case) and thus
occur before the load case declarations.

compliance, to be defined on the


factors for each load case included
objective and constraint are global
the DESOBJ and DESGLB statements

$
DESOBJ = 50
DESGLB = 101
$
SUBCASE 1
LOAD
= 2
SPC
= 1
WEIGHT = 2.0
$
SUBCASE 2
LOAD
= 3
SPC
= 1
WEIGHT = 1.0
$
BEGIN BULK
$
DRESP1, 50, wcomp, WCOMP
$
DRESP1, 100, weight, MASS
DCONSTR, 101, 100, , 1.560
$
Maximize Frequency for Constrained Volume
The setup for this deck is similar to that for the first two decks except that, starting with
OptiStruct 5.0, the volume response now refers to the actual volume (not the volume
fraction).
$
DESGLB = 101
$
SUBCASE 1
METHOD = 2
SPC = 1
DESOBJ(MAX) = 1
$

Altair Engineering

OptiStruct 13.0 Reference Guide 2385


Proprietary Information of Altair Engineering

BEGIN BULK
$
DRESP1, 1, freq1, FREQ, , , 1
$
DRESP1, 100, vol, VOLUME
DCONSTR, 101, 100, , 20000.0
$

Maximize Weighted Frequencies for Constrained Volume


In OptiStruct 3.5, the weighted frequency response (wfreq), was minimized since the inverse
of the eigenvalues was being summed together. This was done so that increasing the
frequencies of the lower modes would have a larger effect on the objective function than
increasing the frequencies of the higher modes. If the frequencies of all modes are simply
added together, OptiStruct will put more effort into increasing the higher modes than the
lower modes. Note that the DESOBJ statement goes above the first load case since wfreq is
a global response. To duplicate the frequency weighting and summing in OptiStruct 3.5, use
the following approach:
$
DESGLB = 101
$
DESOBJ(MIN) = 11
SUBCASE 1
METHOD
= 2
SPC
= 1
MODEWEIGHT, 1, 1.0
MODEWEIGHT, 2, 1.0
$
BEGIN BULK
$
DRESP1, 11, wfreq, WFREQ
$
DRESP1, 100, vol, VOLUME
DCONSTR, 101, 100, , 20000.0
$

Minimize Combined Compliance and Frequencies for Constrained Volume Fraction


In OptiStruct 3.5, the combined reciprocal frequency and compliance response (comb)
required a normalization factor in order to properly add frequency values and compliance. The
equivalent setup for OptiStruct 5.0 and higher is shown below.
If no NORM is given, OptiStruct will evaluate the frequencies and compliances in the initial
iteration step to automatically select a NORM factor.
$
DESOBJ(MIN) = 50
DESGLB
= 101
$
NORM = 1000.0
$
SUBCASE 1

2386 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

LOAD
= 2
SPC
= 1
WEIGHT = 1.0
$
SUBCASE 2
LOAD
= 3
SPC
= 1
WEIGHT = 1.0
$
SUBCASE 3
METHOD = 10
SPC
= 1
MODEWEIGHT, 1, 1.5
MODEWEIGHT, 2, 1.0
$
BEGIN BULK
$
DRESP1, 50, comp, COMB
$
DRESP1, 100, volf, VOLFRAC
DCONSTR, 101, 100, , 0.300
$

Altair Engineering

OptiStruct 13.0 Reference Guide 2387


Proprietary Information of Altair Engineering

Previously Supported Input


BEAD (Not Supported in 8.0 or Later Versions)
MASSTOH3D (Not Supported in 8.0 or Later Versions)
ROTATION (Not Supported in 8.0 or Later Versions)
DOPTPRM, MINMETH (Not Supported in 8.0 or Later Versions)
PARAM, PRTRENUM (Not Supported in 9.0 or Later Versions)
INFILE (Not Supported in 10.0 or Later Versions)
PARAM, GAPOFFST (Not Supported in 10.0 or Later Versions)
SET/PSET (Not Recommended for use in 10.0 or Later Versions)
DENSRES (Not Recommended for use in 10.0 or Later Versions)
SHRES (Not Recommended for use in 10.0 or Later Versions)
FLSPOUT (Not Supported in 11.0 or Later Versions)
PARAM, INRGAP (Not Supported in 11.0 or Later Versions)
MODELMPC (Not Supported in 12.0 or Later Versions)
PARAM, AMLSASPC (Not Supported in 12.0 or Later Versions)
UPDATE (Not Supported in 12.0 or Later Versions)

2388 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

BEAD (Not Supported in 8.0 or Later Versions)


Bulk Data Entry
BEAD Topography Design Variables
Description
Defines parameters for the generation of topography design variables.
Format
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BEAD

BID

MW

ANG

BF

HGT

norm/
XD

YD

ZD

SKIP

FID/XF

YF

ZF

AID/XA

YA

ZA

LB

UB

TYP

SID/XS

YS

ZS

UC YC

Example
(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

BEAD

3.0

60.0

yes

5.0

norm

both

0.0

1.0

0.0

0.0

25.0

0.0

50

1.0

0.0

0.0

Field

Contents

BID

PID or DID (Integer > 0; no default). This field can contain the PSHELL
or PCOMP property ID of the elements or the desvar number of any set
of DVGRIDs present in the deck to be optimized for topography. If field
6 contains data, OptiStruct will assume that the BEAD card references
a property, otherwise it assumes that the card references a DESVAR
and its corresponding DVGRIDs.

Altair Engineering

OptiStruct 13.0 Reference Guide 2389


Proprietary Information of Altair Engineering

Field

Contents

MW

Bead minimum width (Real > 0.0; no default). This parameter controls
the width of the beads in the model [recommended value between 1.5
and 2.5 times the average element width]. See comment 1.

ANG

Draw angle in degrees (1.0 < Real < 89.0; no default). This parameter
controls the angle of the sides of the beads [recommended value
between 60 and 75 degrees]. See comment 1.

BF

Buffer zone (yes or no; default = yes). This parameter will establish
a buffer zone between elements in the design domain and elements
outside the design domain.

HGT

Draw height: (Real > 0.0; no default). This parameter sets the
maximum height of the beads to be drawn. This field is only valid if a
PID is declared in field 2.

norm/XD,YD,ZD Draw direction (norm in field 7 or Real in all three fields; default =
norm). If field 7 is norm, the shape variables will be created in the
normal directions of the elements. If all the fields are real, the shape
variable will be created in the direction specified by the xyz vector
defined by fields 7, 8, and 9. The X, Y, and Z values are in the basic
coordinate system. This field is only valid if a PID is declared in field 2.
SKIP

Boundary skip (both, bc, spc, load, or none; default = both). This
parameter tells OptiStruct to leave certain nodes out of the design
domain. If none, all nodes attached to elements whose PID was
specified in field 2 will be a part of the shape variables. If bc or spc,
any nodes which have SPC or SPC1 declarations are omitted from the
design domain. If load, any nodes which have FORCE, FORCE1,
MOMENT, MOMENT1, or SPCD declarations are omitted from the design
domain. If both, nodes with either spc or load declarations are
omitted from the design domain. This field is only valid if a PID is
declared in field 2.

FID/XF,YF,ZF

Direction of first vector for variable pattern grouping (Real in all three
fields or Integer in field 12; default = blank). These fields define an xyz
vector which determines how grids are grouped into variables. The X,
Y, and Z values are in the global coordinate system. You may put a
grid ID in field 12 to define the first vector. This vector goes from the
anchor point to this grid. If all fields are blank and field 20 is not blank
or zero, OptiStruct gives an error.

AID/XA,YA,ZA

Variable grouping pattern anchor point (Real in all three fields or integer
in field 15; default = blank). These fields define a point which

2390 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Field

Contents
determines how grids are grouped into variables. The X, Y, and Z
values are in the global coordinate system. You may put a grid ID in
field 15 to define the anchor point.

LB

Lower bound on variables controlling grid movement (Real < UB, default
= 0.0). This sets the lower bound on grid movement equal to LB*HGT.

UB

Upper bound on variables controlling grid movement (Real > LB, default
= 1.0). This sets the upper bound on grid movement equal to UB*HGT.

TYP

Type of variable grouping pattern. (Integer > 0, default = 0) Required


if any symmetry or variable pattern grouping is desired. If zero or
blank, anchor node, first vector, and second vector definitions are
ignored. If less than 20, second vector definition is ignored.

SID/XS,YS,ZS

Direction used to determine second vector for variable pattern grouping


(Real in all three fields or Integer in field 22; default = blank). These
fields define an xyz vector which, when combined with the first vector,
form a plane. The second vector is calculated to lie in that plane and
is perpendicular to the first vector. The second vector is sometimes
required to determine how grids are grouped into variables. The X, Y,
and Z values are in the global coordinate system. You may put a grid
ID in field 22 to define the second vector. This vector goes from the
anchor point to this grid. If all fields are blank and field 20 contains a
value of 20 or higher, OptiStruct gives an error.

UCYC

Number of cyclical repetitions for cyclical symmetry (Integer > 0 or


blank; default = 0). This field defines the number of radial "wedges" for
cyclical symmetry. The angle of each wedge is computed as 360.0 /
UCYC.

Comments
1. The BEAD bulk data entry will no longer be supported for the definition of topography
optimization. All definitions must be provided using the DTPG bulk data entry. HyperMesh
will continue to read BEAD entries, but will convert them into DTPG entries.

Altair Engineering

OptiStruct 13.0 Reference Guide 2391


Proprietary Information of Altair Engineering

DOPTPRM, MINMETH (Not Supported in 8.0 or Later


Versions)
Parameter

Values

Description

MINMETH

Integer = 1,2
Default = 2

Specifies the method of minimum member size control.


Method 2 is set as default since it achieves more
discrete solutions for most examples.

2392 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MASSTOH3D (Not Supported in 8.0 or Later Versions)


I/O Options Entry
MASSTOH3D - Output Request
Description
The MASSTOH3D command can be used in the I/O Options section to request the output of the
mass matrix to the .h3d file.
Format
MASSTOH3D = option

Argument Options

Description

option

YES, ALL, blank: Mass matrix is output to .h3d


file.

<YES, ALL, NO, NONE,


blank>
Default = ALL

Mass matrix is not output.

NO, NONE:

Comments
1.

Mass matrix is not output if this card is not present.

2.

This option is only for use with MotionView's MBD Flexbody utility.

Altair Engineering

OptiStruct 13.0 Reference Guide 2393


Proprietary Information of Altair Engineering

ROTATION (Not Supported in 8.0 or Later Versions)


I/O Options Entry
ROTATION - Output Request
Description
The ROTATION command can be used in the I/O Options or Subcase Information sections to
request the output of rotation information for all subcases or individual subcases respectively.
Format
ROTATION (format, form) = option

Argument

Options

Description

format

<HM, H3D, OPTI,


PUNCH, OUTPUT2,
PATRAN, APATRAN,
blank>

HM:

Results are output in HyperMesh


results format (.res file).

H3D:

Results are output in Hyper3D


format (.h3d file).

OPTI:

Results are output in OptiStruct


results format (.disp file).

PUNCH:

Results are output in Nastran punch


results format (.pch file).

OUTPUT2:

Results are output in Nastran


output2 format (.op2 file).

PATRAN:

Results are output in Patran format


(multiple files).

APATRAN:

Results are output in Alternative


Patran format (multiple files).

blank:

Results are output in all active


formats for which the result is
available.

Default = blank

2394 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

Argument

Options

Description

form

<COMPLEX, REAL,
IMAG, PHASE,
BOTH>

COMPLEX, blank: Provides a combined magnitude/


phase form of complex output to
the .res file if HM output format is
chosen. The REAL form of complex
output is used for other formats, if
they are not specifically defined.
(Phase output is in degrees).

Default = COMPLEX

option

REAL, IMAG:

Provides rectangular format (real


and imaginary) of complex output.

PHASE:

Provides polar format (magnitude


and phase) of complex output.
Phase output is in degrees.

BOTH:

Provides both polar and rectangular


formats of complex output.

<YES, ALL,
NO, NONE, SID>

YES, ALL, blank: Rotations are output for all nodes.

Default = ALL

NO, NONE:

Rotations are not output.

SID:

If a set ID is given, rotations are


output only for nodes listed in that
set.

Comments
1. When a ROTATION command is not present, rotations are not output.
2. The form argument is only applicable for frequency response analysis. It is ignored for
other analysis types.
3. The form BOTH does not apply to the .frf output files. Results are output to these files
using the rectangular form of complex output when BOTH is the chosen form.
4. Multiple formats are allowed on the same entry; these should be comma separated. If no
format is specified, then this output control applies to all formats defined by OUTPUT or
FORMAT commands for which the result is available. See Results Output for information on
which results are available in which formats.

Altair Engineering

OptiStruct 13.0 Reference Guide 2395


Proprietary Information of Altair Engineering

5. Multiple instances of this card are allowed; if instances are conflicting, the last instance
dominates.
6. For optimization, the frequency of output to a given format is controlled by the I/O option
OUTPUT. In previous versions of OptiStruct, a combination of the I/O options FORMAT
and RESULTS were used; this method is still supported, but not recommended as it does
not allow different frequencies for different formats.

2396 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

FLSPOUT (Not Supported in 11.0 or Later Versions)


I/O Options and Subcase Information Entry
FLSPOUT Output Request
Description
The FLSPOUT command can be used in the I/O Options section to control output of modal
participation factors for coupled fluid-structure models.
Format
FLSPOUT(argument = option, argument = option, ...)

Argument

Options

Description

FLUIDMP

<ALL, NONE>

Requests fluid participation calculation of fluid response on


selected fluid points.

Default = NONE

GRIDFMP

ALL:

Requests that all the fluid modes extracted be


used.

NONE:

Requests no participation calculation.

Requests inclusion or exclusion of specific fluid grids to be


used in all the requested types of participation
calculations.

<SID>
No default

SID:

FEPS

<Real>

Set identification number - Results are output


only for fluid grids listed in the selected set.

Filter Threshold for fluid participation.

Default = 1.0e-11

ARF

<Real>

Acceptance ratio for fluid participation.

Default = 1.0e-11

Altair Engineering

OptiStruct 13.0 Reference Guide 2397


Proprietary Information of Altair Engineering

Argument

Options

Description

STRUCTMP

<ALL, NONE>

Requests structural, load, and panel participation


calculations on the selected fluid points.

Default = NONE

PANELMP

<ALL>
Default = ALL

ALL:

Requests that all the structural modes extracted


be used.

NONE:

Requests no participation calculation.

Requests inclusion or exclusion of panel participation


calculations on the selected fluid points.
ALL:

SEPS

<Real>

Requests that all the panels defined be included


in the participation calculations on the selected
fluid points.

Filter Threshold for structural participation.

Default = 1.0e-11

ARS

<Real>

Acceptance ratio for structural participation.

Default = 1.0e-11

PSORT

<ABSOLUTE>

Requests type of sort.

Default =
ABSOLUTE
Comments
1.

GRIDFMP is required for all FLSPOUT statements.

2.

FLUIDMP and STRUCTMP are required when PANELMP is defined.

3.

The output file name for modal participation is *.modal.

2398 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

MODELMPC (Not Supported in 12.0 or Later Versions)


Subcase Information Entry
MODELMPC
Description
MODELMPC command can be used in the Subcase Information section while including h3d DMIG
in residual runs. This card converts interior DOFs of the DMIG to exterior DOFs.
Format
MODELMPC = setdof
Examples
MODELMPC = 100
SET,100,GRIDC,
+,10643,T1,10643,T2,10643,T3

Argument

Option

Description

setdof

< SID >

Interior DOF of h3d DMIG to be converted into exterior


DOF. SID refers to the ID of a SET of type GRIDC.

Comments
1.

After the conversion with MODELMPC, these DOFs are part of the analysis DOFs and can be
used as connection points, load DOFs, response DOFs during optimization.

Altair Engineering

OptiStruct 13.0 Reference Guide 2399


Proprietary Information of Altair Engineering

PARAM, AMLSASPC (Not Supported in 12.0 or Later


Versions)
Parameter
AMLSASPC

Values

Description

0, 1
Default = 0

This parameter is used to indicate when to automatically


constrain degrees-of-freedom with no stiffness for AMLS
run.
If 0, then the constraints are applied before constraint
reduction.
If 1, then the constraints are applied after constraint
reduction.

2400 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, GAPOFFST (Not Supported in 10.0 or Later


Versions)
Parameter

Values

Description

GAPOFFST

YES, NO
Default = YES

If YES, frictional offset for nonlinear gap analysis is


active.
If NO, frictional offset for nonlinear gap analysis in
inactive.
For more details, refer to the PGAP description.

Altair Engineering

OptiStruct 13.0 Reference Guide 2401


Proprietary Information of Altair Engineering

PARAM, INRGAP (Not Supported in 11.0 or Later


Versions)
Parameter

Values

Description

INRGAP

<YES, NO>
Default = NO

PARAM, INRGAP can be used during nonlinear gap analysis


to improve the performance for some models. In this
method, an internal super element which includes all of
the gap elements is created automatically, and the
nonlinear iterations are only processed in this super
element. If the degrees-of-freedom associated with gap
elements make up less than 3% of the total degrees-offreedom and the gap elements are concentrated in one
area of the model, this approach may be beneficial.
However, a performance gain is not guaranteed.

2402 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

PARAM, PRTRENUM (Not Supported in 9.0 or Later


Versions)
Parameter

Values

Description

PRTRENUM

<YES, NO, LIST>


Default = YES

If YES, prints a warning message when element


nodes have been renumbered, including the number
of such elements. (Renumbering is applied to
elements that have node sequence reversed with
respect to the standard numbering as described on
respective bulk data cards).
If NO, no such message is printed.
If LIST, the warning message is printed for every
element where renumbering was necessary. The
message includes the node list before and after
renumbering.

Altair Engineering

OptiStruct 13.0 Reference Guide 2403


Proprietary Information of Altair Engineering

UPDATE (Not Supported in 12.0 or Later Versions)


I/O Options and Subcase Information Entry
UPDATE Input Definition
Description
The UPDATE command controls the behavior of ASSIGN,UPDATE,<filename>.
Format
UPDATE option
Option

Description

off

Disable update.

permissive

Allow all cards and repeat IDs.

quiet

Less output [default].

strict

Do not allow non-supported cards in update deck


[default].

unique

Each ID only once.

verbose

More output including old and new values.

Example
UPDATE verbose,unique
Comments
1.

Choose only one option: verbose or quiet.

2.

Choose only one option: unique, strict, permissive, or off.

2404 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

INFILE (Not Supported in 10.0 or Later Versions)


I/O Options Entry
INFILE - File Selection
Description
The INFILE command is used in the I/O Options section to identify the file containing the bulk
data entries.
Format
INFILE = option

Argument

Option

Description

option

<file prefix>

file prefix: The path to and prefix of the .fem


file containing the bulk data entries.

Default = passed
in from the
command line.
Comments
1. This card is used in the obsolete two-file setup; the one-file or multiple-file setups are
recommended (see The Input File for more information).
2. Prefixes specified on the INFILE card can be arbitrary file prefixes with optional paths
appropriate to the operating system (Windows or UNIX). They may be enclosed in
quotes (double or single quotes can be used), and either forward slash (/) or back slash
(\) characters can be used to separate parts of the path name.
The following rules are used to locate a file referenced on the INFILE card:
When the argument contains the absolute path of the file (if it starts with "/" on UNIX
or a drive letter, such as "D:", on Windows, for example), the file at the given location
is used.
When only the file prefix is given (without the path), the file has to be located in the
same directory as the file containing the INFILE command.
When the argument contains a relative path (../filename or sub/filename, for
example), it is located in the directory relative to the file containing the INFILE
command and is NOT relative to the directory in which the solver was executed, or to
the directory where the main file is located.
3. The total length of information on this card is limited to 200 characters (including the card
name and spaces between arguments). This data can be on a single line or span multiple
continuation lines. See Guidelines for I/O Options and Subcase Information Entries for an
example showing how to enter long file names on multiple lines.

Altair Engineering

OptiStruct 13.0 Reference Guide 2405


Proprietary Information of Altair Engineering

SET/PSET (Not Recommended for use in 10.0 or Later


Versions)
I/O Options and Subcase Information Entry
SET - Set Definition
PSET - Set Definition
Description
The SET and PSET commands can be used in the I/O Options or Subcase Information section
input deck to define sets of grids, elements, properties, or frequencies.
Format
SET n = i1, i2, , in

Integer sets are used for sets of grids,


elements, modes, and design variables.

SET n = r1, r2, , rn

Real value sets are used for frequencies or


times.

SET n = i1, c1, i2, c2, , in, cn

Sets of Gird/Component pairs are used for


PFMODE data.
Example:
SET 24 = 12, T1, 15, R2, 128, T3
(alternatively 12/T1, 15/R2, 128/T3 is
acceptable, see Guidelines for I/O Options
and Subcase Information Entries).

PSET n = PID1, PID2, , PIDn

Property identification numbers are used for


property set definition.

Comments
1.

Every SET must have a unique identification number, n, regardless of whether the SET is
defined within a subcase or in the I/O Options section. Also, a SET cannot have the same
ID as a PSET or the bulk data entries SET, SET1, or SURF.

2.

From 10.0 onwards, it is recommended to use the SET bulk data entry for set definitions.

2406 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

DENSRES (Not Recommended for use in 10.0 or Later


Versions)
I/O Options Entry
DENSRES - Output Control
Description
The DENSRES command can be used in the I/O Options section to control the frequency of
output of design results (density, shape, or thickness).
Format
DENSRES = frequency

Argument Options

Description

frequency

FIRST:

Optimization results are output for the first


iteration only.

LAST:

Optimization results are output for the final


iteration only.

FL:

Optimization results are output for the first


and last iterations only.

ALL, blank:

Optimization results are output for all


iterations.

N:

Optimization results are output for the first


and last iterations and every Nth iteration.
If N = 5, output occurs for iterations 0, 5,
10, 15, 20, and so on, and the final
iteration.

<FIRST, LAST,
FL, ALL, N>
Default = ALL

Comments
1.

This output control is ignored if OUTPUT, DESIGN is present.

2.

When the DENSRES command is not present, results are output for all iterations.

3.

From 10.0 onwards, it is recommended to use the OUTPUT I/O Option entry to control this
output.

Altair Engineering

OptiStruct 13.0 Reference Guide 2407


Proprietary Information of Altair Engineering

SHRES (Not Recommended for use in 10.0 or Later


Versions)
I/O Options Entry
SHRES - Output Control
Description
The SHRES command can be used in the I/O Options section to control the frequency of
output of the state files (.sh file and the .grid file).
Format
SHRES = frequency

Argument

Options

Description

frequency

<FIRST, LAST,
FL, ALL, NONE, N>

FIRST:

The files are output for the first


iteration only.

LAST, blank:

The files are output for the final


iteration only.

FL:

The files are output for both the


first and last iterations.

ALL:

The files are output for all


iterations.

NONE:

The files are not output.

N:

The files are output for the first


and last iterations and for every
Nth iteration. If N = 5, output
occurs for iterations 0, 5, 10, 15,
20, and so on, and the final
iteration. All equation and
combination responses are output.

Default = LAST

Comments
1.

When a SHRES command is not present, state files are output for the final iteration only.

2.

The .grid file is only output for shape, topography, and free-shape optimization.

2408 OptiStruct 13.0 Reference Guide


Proprietary Information of Altair Engineering

Altair Engineering

3.

For all .sh and .grid output files bar the last one, the files are named
<prefix><iter#>.sh(.grid). The last one is just named <prefix>.sh(.grid).

4.

The .grid file output may also be controlled by the GRID keyword on the OUTPUT card.

5.

From 10.0 onwards, it is recommended to use the OUTPUT I/O Option entry to control this
output.