You are on page 1of 2

Inverter 4-Way Cassette

Economical, energy-efficient eco-friendly


airconditioning for larger areas

Energy-efficient Inverter heating/cooling for larger areas


Available in sizes from 24 000 BTU to 48 000 BTU
Single and 3-phase models
75m piping length to outdoor unit/30m elevation
Environmentally-friendly R410A gas
Supported nationwide by Samsung Air

Inverter 4-Way Cassette


Economical, energy-efficient eco-friendly
airconditioning for larger areas
W ith electricity prices constantly on the increase, the modern trend is
towards Inverter technology. The range of Samsung Inverter 4-Way Cassettes
is the quality route to airconditioning of larger upmarket domestic areas or
commercial applications.
S P E C I F I C AT I O N S
Model
Capacity (Min./Standard/Max)
Power Input (Min./Standard/Max)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
INDOOR UNIT
Model
Panel
Fan Type
Air Flow Rate
Set
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Panel
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Sound Pressure Level *3)
Indoor Filter
OUTDOOR UNIT
Model
Compressor
Refrigerant
Set
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.

Indoor unit
CH070EAV1
Outdoor unit
UH070EAV1
2,100/7,100/8,400
Cooling *1) Watts
2,000/8,000/11,600
Heating *2) Watts
510/2,120/2,700
Cooling
Watts
500/2,190/3,750
Heating
Watts
3.35(A)
Cooling
W/W
3.65(A)
Heating
W/W
2.8/9.3/12.1
Cooling
Amps
2.6/9.6/16.9
Heating
Amps
6.35(1/4)
Liquid
mm (inch)
15.88(5/8)
Gas
mm (inch)
1/220-240/50
/V/Hz

WxHxD
WxHxD
WxHxD
WxHxD
High/Low

Type
WxHxD
WxHxD

Cooling
Heating

m3/min
mm
mm
kg
mm
mm
kg
dB(A)

mm
mm
kg
dB(A)
C
C
g
m
m
m
g/m

CH090EAV
UH090EAV
3,200/9,000/10,000
3,000/10,000/13,900
750/2,800/3,200
580/2,770/4,660
3.21(A)
3.61(A)
3.5/12.5/14.1
2.8/12.2/20.6
9.52(3/8)
15.88(5/8)
1/220-240/50

CH105EAV
UH105EAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
3.3/14.5/16.8
3.6/13.7/24.3
9.52(3/8)
15.88(5/8)
1/220-240/50

CH105EAV
UH105GAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
1.3/5.0/6.0
1.1/5.0/8.6
9.52(3/8)
15.88(5/8)
3/380-415/50

CH140EAV
UH140EAV
3,800/14,000/15,400
3,450/16,000/18,500
900/4,650/5,400
750/4,690/5,800
3.01(B)
3.41(B)
4/20.6/23.5
3.6/20.8/26.5
9.52(3/8)
19.05(3/4)
1/220-240/50

CH140EAV
UH140GAV
3,800/14,000/15,400
3,450/16,000/18,500
900/4,650/5,400
750/4,690/5,800
3.01(B)
3.41(B)
1.4/7.2/8.5
1.3/7.3/10.2
9.52(3/8)
19.05(3/4)
3/380-415/50

CH070EAV1
P4SMA
TURBO FAN
17.2
840x218x840
926x280x925
31/35
950x35x950
1,042x103x1,042
7.0/10.3
36/30
DEFAULT

CH090EAV
P4SMA
TURBO FAN
24
840x298x840
925x360x925
29/35
950x35x950
1,042x103x1,042
7.0/10.3
39/32
DEFAULT

CH105EAV
P4SMA
TURBO FAN
25.7
840x298x840
925x360x925
29/35
950x35x950
1,042x103x1,042
7.0/10.3
40/33
DEFAULT

CH105EAV
P4SMA
TURBO FAN
22.2/25.7
840x298x840
925x360x925
29/35
950x35x950
1,042x103x1,042
7.0/10.3
40/33
DEFAULT

CH140EAV
P4SMA
TURBO FAN
30
840x298x840
925x360x925
29/35
950x35x950
1,042x103x1,042
7.0/10.3
45/38
DEFAULT

CH140EAV
P4SMA
TURBO FAN
28/30
840x298x840
925x360x925
29/35
950x35x950
1,042x103x1,042
7.0/10.3
45/38
DEFAULT

UH070EAV1
TWIN BLDC
R410A
880x798x310
1,038x861x413
57/61
52
-15~43
-20~24
1,900
50
30
5
30

UH090EAV
TWIN BLDC
R410A
932x1,128x375
1,091x1,286x472
95/110
56
-15~50
-20~24
2,600
75
30
7.5
40

UH105EAV
TWIN BLDC
R410A
932x1,128x375
1,091x1,286x472
95/110
56
-15~50
-20~24
2,800
75
30
7.5
40

UH105GAV
TWIN BLDC
R410A
932x1,128x375
1,091x1,286x472
88/93
56
-15~50
-20~24
2,800
75
30
7.5
40

UH140EAV
TWIN BLDC
R410A
932x1,128x375
1,091x1,286x472
105/120
59
-15~50
-20~24
3,100
75
30
7.5
40

UH140GAV
TWIN BLDC
R410A
932x1,128x375
1,091x1,286x472
105/120
59
-15~50
-20~24
2,800
75
30
7.5
40

1. Nominal cooling capacities are based on: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB, 24 CWB; Equivalent ref. piping: 7.5m. Level differences: 0m
2. Nominal heating capacities are based on: Indoor temp: 20 CDB, 15 CWB; Outdoor temp: 7 CDB, 6 CWB; Equivalent ref. piping: 7.5m. Level differences: 0m.
3. Sound pressure acquired in a dead room; actual noise level may differ depending on installation conditions.

S o l d a n d s u p p o r t e d n a t i o n w i d e by :

w w w. s a m s u n g a i r. c o. z a

Gauteng &
Central region
(011) 704-6320

Pretoria
(012) 661-2002

Western, Eastern &


Northern Cape
(021) 556-8292

Due to Samsung's policy of constant improvement, specifications are subject to change without notice. E&OE

Kwa-Zulu Natal
(031) 579-1895

You might also like