You are on page 1of 3

HAReview

1:

CanyouunlicenseaNetappCluster?

Yes,iftheclusterisfirstdisabled.Frombothconsoles,runthefollowingcommands:
1. Typecfdisable.Thismanuallydisablesclusterfunctionality.
2. Removelicensecodesandpermanentlydisableclusteringcapability.Typelicense
deletecluster.ForDataONTAP6.4andearlier,typelicensecluster=DISABLE.
3. Reviewthe/etc/rcfileforeachfiler,andmodifyanycommandsthatuseapartner
statement
2:

InaMetroClusterwhorunsthedisksinswitchbank1

TheFilerpluggedintoswitchbank2
3:

Whatconditionmustsyncmirrorbeinbeforesplitting

AllPlexesmustbeonlineandoperational
4:

Whatdoesdiskshowvprovide?

Usedtodisplayinformationabouttheownershipofthedisks.
5:

HowisdisasterdefinedinMetroClusterdoumentation?

Prolongedcommunicationdisruption
6:

Inclustertakeovermodedoesthelocalinterfacebecomethefailedpartnerinterface?

Inclustertakeovermodethesharedinterfaceassumestheidentityofboththelocalandfailed
partnerinterfaces.
7:

InaMetroClusterwhatdoestheCLIstorageshowdiskpprovide?

Ifthisparameterisspecified,thecommanddisplaysthefollowingpathrelatedinformation:
Primarypathtothediskandportname
Secondarypathtothediskandportnameinamultipathconfiguration
Type,shelf,andbayinformationforthedisks
8:

InSyncMirrordothedisksforplex0andplex1comefromthesamepool?

No.Aplexcanonlypullsparesfromitsownpool.Thismeansthatifoneplexisoutofsparesanda
differentplexhassparesthefirstplexcannotusethem.Youwillbealertedbutthesystemwillnot
shutdownasitwouldhaveiftherewereonlyoneplex.

Page1of3

HAReview

9:

OntheFAS270cisitpossiblefordiskstonotbeowned?

Yes,butanydiskthatisnotownedcannotbeusedfordataorforaspare.
10:

IsthereaspecialHBArequiredforIPoverFC?

Yes,theNetAppX1024
11:

InSyncMirroriftherearenosparesinthepoolfortheplexthathaslostadisk,whathappens?

Itwarnsyoutherearenosparesavailablebutdoesntdoanythingelse.
12:

InMetroCluster,howdoyouisolatethedisastersitenode?

YoucanuseManualFencingorTurnoffthepowertothedisastersitenode
13:

Whyusethevolsplitcommand?

Twosplitthesyncmirroredvolumeintotwounmirroredvolumes
14:

WhatarethenetworkaccessrequirementsforaNetAppcluster?

Eachnodeintheclustermusthaveaccesstothesamesetofsubnets.
15:

Whataretheresultsofrunningacfforcetakeoverd

Thesurvivingclusternodetakesoverthefunctionsofthefailedpartnerandanymirroredvolumesare
implicitlysplit
16:

WhatisaNegotiatedFailover?

Negotiatedfailoverisafeaturethatenableseachfilerinaclustertonegotiatetakeoverfromonefiler
toitspartnerintheeventofadiskshelffailure.Commonlyhappensifoneheadcanseebothsides
buttheotherheadcanonlyseeitsown.
17:

Whatdoesvolstatusbprovide?

ThebisusedtogetthesizeofsourceanddestinationtraditionalvolumesforusewithSnapMirror.
Theoutputcontainsthesizeofthetraditionalvolumeandthesizeofthefilesysteminthevolume
18:

CanyoudisabletheSyncMirrorlicense?

Yes,aslongasnomirroredvolumesexist
19:

HowmanylicensesdoyouneedtosetupFabricAttachedMetroCluster?

Syncmirror_local,Cluster,Cluster_Remote

Page2of3

HAReview

20:

WhichfilerscannotrunSnapMirrorSync?

F87,F700Series,F810,F820
21:

Whatarethestepstoteardownacluster?
1. Typecfdisable
2. Unlicensedcluster.
3. Removepartnerentriesfornetworkinterfacesfromthe/etc/rcfile.
4. Haltandmakesurethepartnersysidisblank.
5. Powerdownandremovetheclusterinterconnectcard.
6. Performthestepsaboveonthepartnernode.

22:

Isthereanydangerwhenrunningacfforcetakeoverd

Youneedtopoweroffremotenodestoavoiddatacorruption
23:

Whatdoeswaitingforgivebackmean?

Indicatesthestorageapplianceisreadytoreinstatethecluster
24:

InaFabricAttachedMetroClusterhowisdiskownershipdetermined?

DiskownershipisdeterminedbytheSwitchnumberandportstheheadanddisksarepluggedinto.
25:

Howdoyourecoverfromalevel0resynchronizationstate?

ThiserroroccursinaMetroClusterandtherecommendedfixistorecreatethesynchronousmirror.
26:

UsingaFAS960SyncMirrorsolutionwhatslotswouldtheadaptorsfordiskpool0bein?

Slots2,3,4,5,6

Page3of3