Professional Documents
Culture Documents
2. Quick-Start Checklist
TABLE OF CONTENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Channel Setting
Center Frequency
Center Frequency Offset
Attenuation Setting
3
4
4
5
7
7
7
3.
Mechanical Installation
4. Wall Mounting
Wall
Mounting
bracket
miniRepeater
V1550_X03
M0041AFM.doc
6. Functional Description
G0783ZR
MR2003D
7. Cabinet Drawing
Channel Setting
CF setting (positions 0 - B)
G0825Z8
CF switch
8. Mechanical Specification
Height x Width x Depth:
MR2003B/D:
114 x 154 x 51.5 mm
(4.5 x 6 x 2 inch)
MR2003B/D-SMS: 226 x 310 x 75 mm
(8.9 x 12 x 3 inch)
Weight:
MR2003B/D:
0.7 kg (1.5 lb)
MR2003B/D-SMS: 2 kg (4.4 lb)
Sealing Class:
MR2003B/D:
MR2003B/D-SMS:
CFO switch
LEDs
IP30
IP20
CF setting (positions 0 - B)
M0041AFM.doc
Page 3
10.2.
Center Frequency
The position of the CF rotary switch and the type of SAW filter used (5 MHz, 10 MHz or 15 MHz) decide which
channel(s) of the UMTS band will be amplified.
1
0
2
1
3
2
4
3
5
4
6
5
7
6
8
7
9
8
10
9
11
10
12
11
UMTS-Channel
CF-Setting
1920
1930
1940
1950
1960
1970
1980
MHz (UL)
2110
2120
2130
2140
2150
2160
2170
MHz (DL)
0
0
1
1
2
2
3
3
4
4
0
0,1
1
1,2
2
2,3
3
3,4
4
4,5
0
0-2
1
1-3
2
2-4
3
3-5
4
4-6
5 MHz
6
7
6
7
10 MHz
5
6
7
5,6
6,7
7,8
15 MHz
5
6
7
5-7
6-8
7-9
5
5
8
8
9
9
A
10
B
11
8
8,9
9
9, 10
A
10,11
B
---
8
8-10
9
9-11
A
---
B
---
CF setting
10.3.
A center frequency offset from 0 to 700 kHz (+ or -) may be set in steps of 100 kHz. Each rotary switch position
equals one step, no CFO is set at positions 0 and 8. Positions 1-7 set a CFO of +100 kHz per step, positions F-9
set a CFO of -100 kHz per step.
Rotary
switch pos.
CFO in 100
kHz
+1
+2
+3
+4
+5
+6
+7
-1
-2
-3
-4
-5
-6
-7
CFO setting
10.4.
Attenuation Setting
Output connector
LED 1
LED 2
Output-Contact Configuration
6 GND
Output1
(TTL level)
Output2
(Optocoupler
output)
Output3
(Optocoupler
output)
5 Heartbeat
Hardware1
Alarm C
Hardware3
Alarm E
2 ALC-Alarm C
4 ALC-Alarm E
Output-contact configuration
LED 1
LED 2
M0041AFM.doc
Page 5
11.3.
Output-Contact Descriptions
Output1:
+5
1kOhm
not allowed
1h
24 h
not allowed
3
4
5
6
7
8
2h
3h
4h
5h
6h
12 h
B
C
D
E
F
30 h
36 h
48 h
60 h
72 h
18 h
Heartbeat-switch settings
MR2003B
In a remote control system, heartbeat signalling is a
very useful method to monitor whether the supervision
connection to a device is still alive. Without heartbeat
signalling, there would be no indication in case the
supervision connection broke down and the OMC
would show no alarm because it no longer received
any information.
For simple remote control, a standard SMS alarm
transmitter is provided. Connecting this SMS alarm
transmitter to the heartbeat signalling output will
initiate regular SMS sending to the OMC, thus,
indicating that the connection to the device is still alive
and able to report an alarm if there is one. If the
connection is down or the device is malfunctioning,
there will be NO heartbeat SMS and an alarm is
raised at the OMC.
Output2: This optocoupler output, which is signalling
the operating condition, represents the same
functionality as LED1.
Collector-emitter voltage......50 V max.
Collector current..................20 mA max
o open
o close
13.2.
miniRepeater
o open
o close
Heartbeat
(output1)
HW
( t t2)
ALC Alarm
Alarm
Heartbeat
HW
(output2)
(output3)
(output1)
Alarm
ALC Alarm
(output3)
13. Application
miniRepeater
miniRepeater
13.1.
(output1)
HW Alarm (output2)
ALC Alarm
(output3)
SMS Transmitter
S
M
S
GSMMODEM
G
e
n
e
r
a
t
o
r
PSU
Heartbeat
HW
(output2)
ALC Alarm
(output1)
Heartbeat
Alarm
HW
(output2)
ALC Alarm
(output3)
HW ALC
Alarm Alarm
(output1)
Alarm
(output3)
Summary
Alarm
M0041AFM.doc
Page 7
14.
Directional
coupler
MO9/18
SMS GSM
Transmitter
Heartbeat switch
Directional
coupler
Connector for
donor antenna
MO9/18
SMS GSM
Transmitter
Heartbeat switch
15.
List of Changes
Version
Changes
M0041AFL
M0041AF
M
- Chapter 14 updated
Release
Date
15-Nov.2006
26-June2007
M0041AFM.doc
Page 9