You are on page 1of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

Last Modified: 3-17-2014

6.6 N

Doc ID: RM000004GKI022X

Model Year: 2010

Model: LS600H

Prod Date Range: [11/2009 -

Title: HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

]
]

CHARGING
1. INSPECT AUXILIARY BATTERY VOLTAGE
(a) Measure the voltage between the terminals of the auxiliary battery.
Standard voltage:
Approximately 11 V or more
HINT:
The horn should sound clearly.
If the voltage is 10 V or less, either charge the auxiliary battery (charging usually takes about 1 hour), or
replace it with an auxiliary battery that is already charged.

2. PREPARATION FOR HV BATTERY CHARGING


CAUTION:
The hybrid system has high-voltage circuits. Accidents, such as electric shock, or electric leaks may result
if the hybrid system is not operated in a correct manner. Make sure to follow the correct procedure
Wear insulated gloves.

HINT:
Removing the service plug grip interrupts the high voltage circuit.
High voltage wiring connectors are orange.
(a) Check the charge level of the HV battery.

(1) Check whether the HV battery warning message is shown in


the multi-information display.

(2) Confirm if the engine starts. If the engine starts, leave it idling with the shift lever in P until the engine
stops (self charge has completed).
If the engine cannot start, follow the procedure and charge the HV battery.
HINT:
Before performing external charging, always use the Techstream to perform troubleshooting.
Charging time using the THS charger is 10 minutes per charge cycle. The charging time when using a THS
charger is a short charging time (when the battery temperature is 25C (77F), 10 minutes may be

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 1 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

sufficient, if the battery temperature is 0C (32F), then three 10 minute charge cycles may be required)
for putting the engine in a condition where it can be started (the system can enter the READY-on state).
(The THS charger will automatically stop 10 minutes after charging starts.)
(b) Remove the service plug grip

(c) Remove the V-bank cover sub-assembly

(d) Remove the engine room side cover RH

(e) Remove the cowl top ventilator louver RH


(f) Remove the motor cable cover RH
(g) Remove the inverter cover assembly RH

.
.

(h) Remove the 2 bolts and connector cover assembly.

(i) Check terminal voltage

(j) Remove the inverter terminal cover.


NOTICE:
Lift the inverter terminal cover, keeping it horizontal so that it will not tilt. Failure to do so may break the
inverter cover guide pins.

(1) Remove the 2 bolts.

(2) Insert and gradually rotate a screwdriver between the inverter terminal cover and inverter case near
bolt hole A to raise the terminal cover by approximately 2 mm (0.08in.). (*1)

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 2 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

NOTICE:
Tape the screwdriver tip before use.
(3) Insert and gradually rotate a screwdriver between the inverter terminal cover and inverter case near
bolt hole B to raise the terminal cover by approximately 2 mm (0.08in.). (*2)
NOTICE:
Tape the screwdriver tip before use.
HINT:
Repeat the preceding steps (*1) and (*2) until the inverter cover can be easily removed by hand.
(k) Remove the inverter terminal cover by hand.
NOTICE:
Do not allow any objects to get on the rubber waterproofing seals of the inverter terminal cover.
Do not touch the rubber waterproofing seals.
When removing the inverter terminal cover, do not end the connector terminals for the interlock part.
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry
of foreign matter.
HINT:
The interlock terminals connect to the inverter terminal cover and are located inside the inverter, close to
the guide pin that is beside the three bolts that secure the motor cable terminals.

(l) Remove the 3 bolts and separate the motor cable brackets.

(m) Remove the 5 bolts and pull out the motor cable from the
inverter with converter assembly.
NOTICE:
Cover the hole where the cable was connected with tape or
equivalent (non-residue type) to prevent entry of foreign matter.
When removing the bolts that secure the cable, do not damage
anything inside the inverter with converter assembly.

(n) Remove the 5 bolts and pull out the generator cable from the

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 3 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

inverter with converter assembly.


NOTICE:
Cover the hole where the cable was connected with tape or
equivalent (non-residue type) to prevent entry of foreign matter.
When removing the bolts that secure the cable, do not damage
anything inside the inverter with converter assembly.

(o) Remove the bolt and disconnect the frame wire.

(p) Temporarily reinstall the inverter terminal cover.

(1) Set the inverter terminal cover to the inverter with converter
assembly.
NOTICE:
Check that the sealing rubber is securely installed to the inverter
terminal cover before installing the cover.
Make sure that there are no foreign objects on the rubber
waterproofing seals before installing the inverter terminal cover.
Install the inverter terminal cover while inserting the guide pins
on the both sides of the cover into guide pin holes of the inverter
case.
When installing the inverter terminal cover, do not bend the
connector terminals for the interlock part.

(2) Push in both ends of the inverter terminal cover by hand, keeping it horizontal.
NOTICE:
Insert the inverter terminal cover, keeping it horizontal, preventing it from tilting.
Make sure that both the inverter terminal bolt holes are aligned and in contact with the holes in the
inverter case.
(q) Secure the inverter terminal cover to the inverter with converter assembly with the 2 bolts.
Torque:
8.0 Nm {82 kgfcm, 71inlbf}

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 4 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(r) Measure the resistance according to the value(s) in the table


below.
HINT:
If the shield line of the frame wire is not securely connected to
body ground, the THS charger will not operate. The "FAULT" and
"CABLE CONNECTION" warning lights will illuminate on the THS
charger.
Standard Resistance:
TESTER CONNECTION

CONDITION

SPECIFIED
CONDITION

Frame wire connector housing - Body


ground

Always

Below 1

(s) If the result is not as specified, inspect the connection shown in


the illustration for proper installation.

(t) Connect the THS charger in the order shown by the circled numbers in the illustration.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 5 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

SST: 09880-10021
09881-10041
SST: 09882-10040
SST: 09882-10070
SST: 09881-10081
NOTICE:
Make sure to connect the EV bonding cable first to prevent electrical shock.
Connect all THS charger cables in the order shown in the illustration to prevent electrical shock.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 6 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(u) Connect the EV bonding cable to the installation bolt of the No.
1 motor cooling pipe.
Torque:
13 Nm {133 kgfcm, 10ftlbf}

(v) Connect the EV bonding cable to the THS charger.

(w) Install the connector cover assembly to the inverter with


converter assembly.

(x) Connect the low voltage cable to the installation bolt of the connector cover.
Torque:
8.0 Nm {82 kgfcm, 71inlbf}

(y) Connect the high voltage cable to the frame wire with the bolt.
Torque:
8.0 Nm {82 kgfcm, 71inlbf}

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 7 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(z) Connect the low voltage cable and high voltage cable to the THS
charger in the order shown in the illustration.

(aa) Install the service plug grip

(ab) Connect the negative (-) auxiliary battery terminal.


(ac) Connect the power input plug of the charger to a grounded AC 100 to 240 V receptacle.
NOTICE:
Always use an AC 100 to 240 V receptacle with a properly functioning ground. The ground is designed to
reduce the chance of electric shock if a malfunction occurs. Do not use the charger if any of the pins on its
plug have been damaged or removed.

3. HV BATTERY CHARGING
(a) Turn the power switch of the vehicle on (IG).
(b) Connect the Techstream to the DLC3.
(c) Enter the following menus: Powertrain / Hybrid Control / Active Test / Battery Charge
HINT:
During the "Battery Charge" Active Test, check "System Main Relay Status - SMRB" and "System Main
Relay Status - SMRG" in the Data List.
If the Data List values are not as specified in the table below, turn the Techstream and the power switch off
and then perform the HV battery charging procedure again.
"SMRB" and "SMRG" in Data List during "Battery Charge" Active Test:
STEP

ACTIVE TEST
BATTERY
CHARGE

THS CHARGER
START

DATA LIST

DATA LIST

SWITCH

SYSTEM MAIN RELAY STATUS SMRB

SYSTEM MAIN RELAY STATUS SMRG

OFF

OFF

OFF

OFF

OFF ON

OFF

OFF ON

OFF ON

ON

OFF ON

ON

ON

(d) Make sure that the EMERGENCY STOP switch is in the reset condition (the switch is turned clockwise and
released).
https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 8 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(e) Make sure that the BREAKER is in the ON position.

(f) Turn the THS charger MAIN switch on.


HINT:
The MAIN indicator will illuminate green.

(g) Press the START switch.

HINT:
When the START switch is turned on, the INITIAL CHECK indicator illuminates and an initial check starts.
When the initial check completes successfully, the INITIAL CHECK indicator turns off, the CHARGING
indicator illuminates and charging will start at the same time.
While the INITIAL CHECK indicator is illuminated, the insulation, 400 V output, emergency stop switch,
connector connections and ground connection are inspected.
(h) Repeat the charge cycle 3 times. When the last cycle has finished, turn the THS charger MAIN switch off.
HINT:
Charging time using the THS charger is 10 minutes per charge cycle. The charging time when using a THS
charger is a short charging time (when the battery temperature is 25C (77F), 10 minutes may be
sufficient, if the battery temperature is 0C (32F), then three 10 minute charge cycles may be required)
for putting the engine in a condition where it can be started (the system can enter the READY-on state).
(The THS charger will automatically stop 10 minutes after charging starts.)
There is very little chance of overcharging the HV battery during the second or third charging cycle. The
SOC will not likely increase beyond the upper limit because it was low enough to prevent the engine from
starting. Even if the SOC was to increase enough to exceed the limit, the hybrid vehicle control ECU will
stop the active test to prevent overcharging.
Cranking the engine once causes the SOC to drop approximately 1%.
Charging the HV battery once (10 minutes) using the THS charger restores the SOC approximately 2%.
(i) Turn the power switch off.
(j) Remove the THS charger and install the frame wire.
NOTICE:
Make sure to disconnect the EV bonding cable last.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 9 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(1) Disconnect the power inlet plug of the charger from the grounded AC 100 to 240 V receptacle.
(2) Disconnect the negative (-) terminal of the auxiliary battery.
(3) Remove the service plug grip

(4) Disconnect the high voltage cable and low voltage cable from
the THS charger in the order shown in the illustration.

(5) Remove the bolt and disconnect the high voltage cable from
the frame wire.

(6) Disconnect the low voltage cable from the installation bolt of
the connector cover.

(7) Remove the connector cover assembly from the inverter with converter assembly.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 10 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

(8) Disconnect the EV bonding cable from the THS charger.

(9) Disconnect the EV bonding cable from the installation bolt of


the No. 1 motor cooling pipe.

(10) Install the cooling pipe with the bolt.


Torque:
13 Nm {133 kgfcm, 10ftlbf}

(11) Install the frame wire to the inverter with converter


assembly with the bolt.
Torque:
8.0. Nm {82 kgfcm, 71inlbf}

(12) Remove the inverter terminal cover.


NOTICE:
Lift the inverter terminal cover, keeping it horizontal so that it will not tilt. Failure to do so may break the
inverter cover guide pins.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 11 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

1. Remove the 2 bolts.


2. Insert and gradually rotate a screwdriver between the inverter terminal cover and inverter
case near bolt hole A to raise the terminal cover by approximately 2 mm (0.08in.). (*1)
NOTICE:
Tape the screwdriver tip before use.
3. Insert and gradually rotate a screwdriver between the inverter terminal cover and inverter
case near bolt hole B to raise the terminal cover by approximately 2 mm (0.08in.). (*2)
NOTICE:
Tape the screwdriver tip before use.
HINT:
Repeat the preceding steps (*1) and (*2) until the inverter cover can be easily
removed by hand.
4. Remove the inverter terminal cover by hand.
NOTICE:
Do not allow any objects to get on the rubber waterproofing seals of the inverter
terminal cover.
Do not touch the rubber waterproofing seals.
When removing the inverter terminal cover, do not bend the connector terminals for
the interlock part.

(13) Connect the generator cable to the inverter with converter


assembly.

(14) Secure the generator cable to the inverter with converter assembly with the 5 bolts.
https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 12 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

Torque:
8.0 Nm {82 kgfcm, 71inlbf}
NOTICE:
When installing the bolts that secure the cable, do not damage anything inside the inverter with converter
assembly.
Make sure that no foreign matter is present on the terminal block.
Make sure to tighten each bolt to the specified torque. Failure to do so may result in damage to the bolt,
cable or inverter with converter assembly.

(15) Connect the motor cable to the inverter with converter


assembly.

(16) Secure the motor cable to the inverter with converter assembly with the 5 bolts.
Torque:
8.0 Nm {82 kgfcm, 71inlbf}
NOTICE:
When installing the bolts that secure the cable, do not damage anything inside the inverter with converter
assembly.
Make sure that no foreign matter is present on the terminal block.
Make sure to tighten each bolt to the specified torque. Failure to do so may result in damage to the bolt,
cable or inverter with converter assembly.

(17) Install the motor cable brackets with the 3 bolts.


Torque:
8.0 Nm {82 kgfcm, 71inlbf}

(18) Install the inverter terminal cover.


1. Set the inverter terminal cover to the inverter with converter assembly.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 13 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

NOTICE:
Check that the sealing rubber is securely installed to the inverter terminal cover before
installing the cover.
Make sure that there are no foreign objects on the rubber waterproofing seals before
installing the inverter terminal cover.
Install the inverter terminal cover while inserting the guide pins on the both sides of
the cover into guide pin holes of the inverter case.
When installing the inverter terminal cover, do not bend the connector terminals for
the interlock part.
2. Push in both ends of the inverter terminal cover by hand, keeping it horizontal.
NOTICE:
Insert the inverter terminal cover, keeping it horizontal, preventing it from tilting.
Make sure that both the inverter terminal bolt holes are aligned and in contact with the
holes in the inverter case.
3. Secure the inverter terminal cover to the inverter with converter assembly with the 2 bolts.
Torque:
8.0 Nm {82 kgfcm, 71inlbf}

(19) Install the connector cover with the 2 bolts.


Torque:
8.0 Nm {82 kgfcm, 71inlbf}

(20) Install the service plug grip

(21) Connect the negative (-) auxiliary battery terminal.


(22) Check if the engine starts.
https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 14 of 15

HYBRID BATTERY CONTROL: HV BATTERY: CHARGING; 2010 MY LS600H [11/2009 -

11/4/14, 4:48 PM

HINT:
If the engine does not start, perform the HV battery charging operation again.
(23) Return the vehicle to its original condition.

4. CHECK HV BATTERY AFTER HV BATTERY CHARGE


(a) Check for DTCs.
(b) Perform the self-charging operation.
(1) Start the engine and leave it idling with the shift lever in P until the engine stops.
HINT:
When the engine stops idling, this indicates that self-charging is complete. Perform any initialization
required after the negative terminal of the auxiliary battery is disconnected and reconnected.

https://techinfo.toyota.com/t3Portal/document/rm/RM14G0U/xhtml/RM000004GKI022X.html?locale=en

Page 15 of 15

You might also like