You are on page 1of 3

2

3 4 56

7 8 9 10

jomayi kira
estate

12
Notes:-

25,248

5
E

2. All walls less than 200mm thick to be reinforced


with hoop iron at every alternate course.

F
G

to namugongo

SITE LOCATION MAP


SEPTIC TANK SCHEDULE

760mm

H2

1600mm

1750mm

Cu. M

760mm

3.2

900mm

4.5

20

10

1900mm

900mm

1800mm

2000mm

2000mm

1000mm

1800mm

2100mm

1100mm

5.9

30

2400mm

1100mm

1800mm

2100mm

1150mm

7.24

40

1300mm

8.6

50

2700mm

1200mm
1300mm

1800mm

2100mm

1800mm

1400mm

2100mm

ARY WA

Wall outline

11. All manholes within building area, driveway and


parking to have heavy duty air tight covers and double
sealed.
12. Provide G.I. 125 x 100 rainwater down pipes and
125 x 100 G.I.box gutter with brackets etc. where
shown.
13. All painting to be 3 coats.
14. Splash apron of 1000mm along the perimeter of
building.
15. Samples of fittings, materials etc. to be produced
&
approved before commencing work.

3,000 cc

16. All windows to have P.C. cills, built in reinforced


concrete Pelmet boxes & timber internal window cills
& Skirtings.

Expansion joint

17. Steel trusses/portal frames & purlins to be


painted with 2 coats of oil paint.

horizontal pointing of block


work only

18. Fire fighting equipment to be provided and


installed by Building Fire Consultants where shown
on plan.
19.These architectural drawings shall be read in
conjunction with the Structural
drawings,Electrical-Mechanical drawings Bills of
Quantities & Technical Specifications. Any discrepancy
shall be reported immediately to the Architect.

25x25mm vertical

RHS at 150mm c.c to

approved gloss paint.

be painted with

20. The Architect shall not accept any liability for


works which he has not been expressly instructed to
Supervise in writing and has accepted to proceed in
writing, or for any ommissions or deviations from his
drawings/technical specifications. Nor shall he take
responsibility for works handled by other nominated
Consultants or Contractors

40x40mm RHS framing

PROPER
TY LINE

27,800

3 4 56

7 8 9 10

11

12

RC coping

SEPTC TANK

230mm thick

No.

fair faced

TO SCHDULE

block wall.

Damp proof
course

Approved
Precast
Concrete
paving on well
levelled sand
blinding on
well rammed
earth

GARDEN
Approved plant species
planted to specialist's
specifications

175

Mr. and Mrs. KAMURASI


DAVID STEVEN
Mob: 0772 881 664
Client's Signature

Strip concrete
foundation mix 1:3:6
19mm aggregate.

architecture
interior design

350

landscape design

ENTRY GATE

1,385

PROPERTY LINE

200

3,000

SECTION A - A

Y12 06 - 200 C/C

Scale 1:50

10Y12 08 - 200 C/C

+256 0752 445026, +256 0701 445026

1,453
Inlet pipe

jp@imparqtassociates.com,
jonpo44@yahoo.com

Project Name and Address


Y12 02-150 C/C both ways (BOT)

SITE PLAN

60

900

3Y12 05-175C/C
12Y12 04-175C/C
Invert level

GROUND LEVEL

SECTION B - B

Scale 1:50

200
WATER PROOF RENDERING IN
TWO 100mm LAYERS EACH
LAYER BRASHED WITH
VANDEX

SECTION THRU SOAK PIT


Drawing Title
20

175

Selected stone

Y12 06 - 200 C/C

50mm BLINDING
50mm blinding

1:100

Y12 10 - 200 C/C

Y12 10 - 200 C/C

Y12 06 - 200 C/C

PROPOSED RESIDENTIAL HOUSE TO BE


BUILT AT BLOCK 192,
PLOT 562 , BUWAATE, KYADONDO
COUNTY - KIRA TOWN COUNCIL,
WAKISO DISTRICT

Selected stone profile.

750

Y12 10 - 200 C/C

1:3 CEMENT/SAND
45o FILLET
3Y12 05-175C/C
RC BEAM
200
150x400mm
10Y12 07 - 200 C/C

15,927

100mm DIA. OUTLET PIPE


TO DRAINAGE SOAK PIT/
PERCOLATION TRENCHES

150
500

H1

150
800

12Y12 04-175C/C

100mm RC SCUM BOARD


CONC. CLASS 25/12

375 150

150
500

450
H2

TOP WATER LEVEL

150

Reg. No.: 203, P.C No.: 1667

20,381

200

50
200

150mm dia. C.I


dip pipe
12Y12 01-175 C/C
4Y12 03-175 C/C

10Y12 09 - 200 C/C

Arch. johnpaul SSENTONGO

50

Scale 1:50

CAST IRON MEDIUM DUTY COVER AND FRAME FOR CAST IRON MEDIUM DUTY COVER AND
CLEAR 600x450mm OPENING AND BEDDED INTO
FRAME FOR CLEAR 600x450mm OPENNING
CEMENT MORTAR
AND BEDDED INTO CEMENT MORTAR
Y12 02 - 150 C/C both ways (BOT)
GROUND LEVEL

INLET PIPE

ARCHITECT

20

BASE SLAB PLAN

Jumbo Plaza. plot 2.


Parliament Avenue.
p.o box 9290. kampala. uganda

Selected filling well compacted and


consolidated.

BOUNDARY WALL TO SCHEDULE

ssociates

mparqt

BOUNDARY WALL DETAILS

Approved Purpose made Steel


sliding door fabricated to
manufacturer's specifications

300

400
350

0TH
B 20
A
L
ES
BAS

CLEAR 750x600mm OPENNING AND BEDDED


INTO CAST IRON MEDIUM DUTY COVER AND
FRAME FOR CEMENT MORTAR

engineering

SECTION THROUGH
C-C (Scale 1:25)

RC

Date

Revision/Issue

Owner

G.L

DRIVE WAY

19,564

PROPERTY LINE

approved gloss paint

400

400

groove

K
L

Approved Precast concrete slabs on sand blinding on well rammed earth

Scale 1:50

L2

25x25mm RHS

H
I
J

PROPOSED MAIN HOUSE BLOCK

400

10. All internal plaster to be two coats steel float


finished.

40

Insitu cast concrete coping

PAVED WALKWAY

19,449
L1

9. Stair case and lobby doors to be self closing and


1/2 hour fire resistant.

150

to be painted with

CONCRETE BENCHING RETURNED


AT SOFFIT HEIGHT OF PIPE AT
1:12 SLOPE

400

150

0TH
B 15
A
L
S
OOF
RC R

350

8. All door frames to be rebated & moulded & be full


width of wall with moulded architrave to detail,
provide rubber door stops to all doors.

Piers to be plastered and


painted.

M
N

7. All windows and external glazed doors on ground


floor to have burglar proofing to Architect's detail.

230X230mm piers at 3000mm centres

2,115

10mm DIA. OUTLET PIPE TO


DRAINAGE SOAK PIT/
PERCOLATION
TRENCHES

ROOF SLAB PLAN

INLET PIPE

6. All waste pipes and soil pipes are to be in ducts and


the bends to have all cleaning eyes accessible from
outside.

2000mm Dia
SOAK PIT x 3000mm
DEEP

60

10

5. Where drain passes under building or driveway area,


pipe to be of cast iron or encased in 150mm concrete.

5000 min

2500mm

K
L

PART PLAN OF BOUNDARY WALL


(Scale 1:50)

600

CROSS SECTION THRU DRAIN


PIPE TRENCH

INTERNAL WATER PROOF TO


WALLS AND SLABS
Scale 1:25

75

75

175 50

1540mm

H1

4. All sanitary work to be in accordance with M.O.H


rules and regulations.

3,000

37,765

L2

NO. OF USERS

DETAIL X (Scale 1:20)

34,718

L1

CAPACITY

36,103

INTERNAL DIMENSIONS

3. All reinforced concrete work is to be in


accordance with structural engineer's details.

40x25mm RHS

8,270

H
I
J

16,788

BUWAATE TRADING
CENTER

BACK YARD

50mm thick sadle coping

BOUND

KIRA TOWN

8,384

8,64

kira town
council
offices

BOUNDARY WALL TO SCHEDULE

C
KIRA

to kyanja

LL TO S

BUWAATE
SWAMP

1. All dimensions to be checked on site, written


dimensions to be followed in preference to scaled
dimensions.

To detail X

1,500

kasangati namugongo road

6,551

7
14,9

CHEDUL

SITE FOR THE


PROPOSED
DEVELOPMENT

14,671

1,995

6,560

buwaate road

1,554

SWAMP

11

40

to kasangati

CONSTRUCTION
DRAWINGS
Scale

CONC. WEIR
BLOCK DETAIL
Scale 1:25

Sheet

AS SHOWN

Date

DEC 2013

KRS/BWT
L[--]01

Drawn by;

T.HENRY

Design by

T.HENRY

elevation e-01

Notes:-

7 8 9 10

11

12

FLOOR

WALL

3 4 56

7 8 9 10

2. All walls less than 200mm thick to be reinforced


with hoop iron at every alternate course.

945

9,845

1,827

S-23

3 4 56

7 8 9 10

5,326

b.

1,369
2,000

SKIRTING

1,942

100x8mm THICK

1,942

755

647

401

GROUND FLOOR PLAN

382

1,792

10. All internal plaster to be two coats steel float


finished.

11. All manholes within building area, driveway and


parking to have heavy duty air tight covers and double
sealed.

2,957

G
20,069

4,185

1,134 866

9. Stair case and lobby doors to be self closing and


1/2 hour fire resistant.

elevation e-02

1,500
1,291

800 765 1,067

8. All door frames to be rebated & moulded & be full


width of wall with moulded architrave to detail,
provide rubber door stops to all doors.

I
J

485

K
L

2,088
600

4,488

M
6,137

4,488

902

926 1,044
1,630

382

1,622

1,132
1,624

1,833

1,526

230
TERRACE

d2-pvo

1,203 797 799 797

9,845

4,000

1,500
1,291
1,700

600
378
1,692

5,285

230

w7-pvo

w6-pvo
3,425

1,997

2,912

600

7. All windows and external glazed doors on ground


floor to have burglar proofing to Architect's detail.

959

1,115

1,250
230
597
1,873

3,085

4,770

4,488

3,031

4,467
230
230

w6-pvo

600

d2-pvo

230

mini bar
w6-pvo

N
O

1:100

3 4 56

14. Splash apron of 1000mm along the perimeter of


building.
15. Samples of fittings, materials etc. to be produced
&
approved before commencing work.
16. All windows to have P.C. cills, built in reinforced
concrete Pelmet boxes & timber internal window cills
& Skirtings.
17. Steel trusses/portal frames & purlins to be
painted with 2 coats of oil paint.
18. Fire fighting equipment to be provided and
installed by Building Fire Consultants where shown
on plan.
19.These architectural drawings shall be read in
conjunction with the Structural
drawings,Electrical-Mechanical drawings Bills of
Quantities & Technical Specifications. Any discrepancy
shall be reported immediately to the Architect.
20. The Architect shall not accept any liability for
works which he has not been expressly instructed to
Supervise in writing and has accepted to proceed in
writing, or for any ommissions or deviations from his
drawings/technical specifications. Nor shall he take
responsibility for works handled by other nominated
Consultants or Contractors

Date

Revision/Issue

5,326

Owner

5,326

7 8 9 10

13. All painting to be 3 coats.

No.

600

Mr. and Mrs. KAMURASI


DAVID STEVEN
Mob: 0772 881 664

elevation e-03

TILE

12. Provide G.I. 125 x 100 rainwater down pipes and


125 x 100 G.I.box gutter with brackets etc. where
shown.

17,112

TO MATCH FLOOR

12

3,200

5,717
230
1,770
230

4,565

382

670

230
945

MASTER
BEDROOM

230

902

600 445
800
800

2,463

730
d2-pvo

w6-pvo

600

3,200

4,770

1,255 858

635

4,488

6. All waste pipes and soil pipes are to be in ducts and


the bends to have all cleaning eyes accessible from
outside.

TERRACE

(open to hallway below)


3,200
797
1,833

1,986

3,471
230

w2-pvo

2,394

VOID

382

1,833

230
230
783
1,770

230

230
1,894
1,019

627

1,302
925

CEMENT SCREED

1,489

1,770

1,250
1,000

1,500
1,291
959

230
4,333

1,500

2,250
1,697

106
1,141 1,118 1,188

d3-pvo

STUDY/
PRAYER
d6-pvo
ROOM

1,718

5. Where drain passes under building or driveway area,


pipe to be of cast iron or encased in 150mm concrete.

1,038

1,593

1,593

1,369

LOBBY

WALK-IN CLOSET
2,970
230 d6-pvo
w2-pvo

2,167 230

TILE SKIRTING

11

4. All sanitary work to be in accordance with M.O.H


rules and regulations.

5,275

230

100x25mm THICK

230

d2-pvo

230

1,394

SKIRTING
a.

1,291

1,038

2,315

773
d6-pvo
675
658
925
943

902

2,000

902

BATH +
WC

1,624

CEILING BOARDS

1,526

PAINT ON SOFT

5,326

1,842

2,519

w2-pvo

703 627
1,623
1,274
787 983
BATH + d5
WC
d3-pvo

902

WHITE EMULSION

2,762

d3-pvo
314 314 703 1,060
975
804

1,942

w2-pvo

744

230 2,880 230

GIRLS'
BEDROOM

w2-pvo

1,622

6,137

w3-pvo

w2-pvo

THICK PLASTER
b.

1,712

1,986

PAINT ON 12mm

4,000

4,000

1,997

K
L

1,500

BOYS' BEDROOM

150 230
829

WHITE EMULSION

230

1,624

a.

K
L

I
J

873

w3-pvo

2,498

FINISH TO CEILING

1,203 797 799 797

w2-pvo

230

2100mm THEN MATT

1,942

1,526

CERAMIC TILES UPTO

902

4,185

6mm THICK GLAZED

CEILING

2,088
1,526

b.

1,622

elevation e-02

2,957
20,069

WALL

elevation e-03

THICK PLASTERED

17,112

MATT PAINT ON 12mm

945

3,389

3. All reinforced concrete work is to be in


accordance with structural engineer's details.

17,527

3,707
4,563
485
1,526
2,088
1,134 866
1,700
521
579
600
600
600
1,526 727
1,675
1,500

1,291

a.

5,326

WALLS

959

1,500

25mm THICK SCREED

14,569

1,500

20,069

4,000

1,593
1,500
1,997
1,700

I
J

485

1,134 866

CERAMIC TILES ON

1,622

1,624

5,476

1,792

6mm THICK NON - SLIP

902

867

5,476

50mm THICK CEMENT


SCREED

b.

959

1,291

1,239
4,027
600
2,370
600

4,330

300

600

600

127
3,036

3,000

1,527 300

1,038

5,511

1,281

600
2,370
600

3,000

a.

elevation e-04

1,369

1,203 797 799 797

600

FLOOR

2,463

401

230

401

1,488

w6-pvo
w6-pvo
803

984 1,200 776 1,067 1,239

3,035
230

230

w6-pvo

3,424

382

TERRACE

4,565

3,993
647

S-23

1,942

647

1,833

d2-pvo

600

3,000

1,624

798

d1-pvo

1,624

5,200
2,463

2,520

3,071

230

w6-pvo

1,942

230

LIVING
ROOM

445

300

797

230
67 730 1,770

4,565

230

230

2,000

ENTRY
HALLWAY

230
1,394
902

3,983

1,574

755

w5-pvo

1,603

303 730 230

2,500

DINING
ROOM

230

1,770

2,454

382 300
230 588 300

3,071

1,056 1,200

230

150 2,910 230


500

940

1,132

230

2,970

933

600
230
1,252
230 1,885

2,880 230 2,312 230


d6-pvo
d4-pvo

952

2,000

230

GUEST w1-pvo
BEDROOM
2

STAIR
LOBBY d3-pvo

500

230
230
970
2,767

d5

d3-pvo

230

2,458

w4-pvo

1,000 161
365
230

1,770

588 300
382 300
150 2,910 230
300

1,000 230
1,162 150
940

230 302
343 30 730
1,817
780

PANTRY

w1-pvo

230

w3-pvo

230

230

w2-pvo

KITCHEN
d6-pvo

4,230

1,770

230

1,031

w2-pvo

4,870

2,463

1,942

d3-pvo
BEDROOM

w9-pvo
230 500
600 169
2,000
900
1,200 993 1,067

1,533

3,055

230

1,942

CEILING

5,275

230

230

TERRACE

1,842

SKIRTING

w8-pvo

1,770

230

d3-pvo

5,326

4,230

230

150
1,179
1,410

810
1,269 1,029

d5

230

1,252

w8-pvo

240 150d5
800 810

1,574

902

1,203 797 799 797

230
1,770w4-pvo 1,770

230

2,155

1,770

1,624

902

1,526

1,622

1,269
1,852

230

w3-pvo
d6-pvo
230
1,715
230

w2-pvo

902

3,389

KITCHEN

GUEST
BEDROOM
1
230 2,880 230

LAUNDRY

w2-pvo

1,622

865

230 2,155

1,000 2,520
230

1,500
1,291
959

230
1,000
1,115
1,252

1,715
d7-pvo

w2-pvo
230

945

230 1,770

2,162

4,230

4,230
230

952

K
L

2,000

w2-pvo
230

14,569

I
J

1,291

G
20,069

elevation e-04

959

3,707
4,563
485
1,526
2,088
1,134 866
1,700
1,997
521
579
582
493
600
600
600
600
582
1,526 727
1,500
885

1,500

1,500

1,038

1,593

4,000

4,000

1,369

2,463
230

1,942

401

12

17,112

3,993
647

230

2,463

1. All dimensions to be checked on site, written


dimensions to be followed in preference to scaled
dimensions.

17,112
1,942

11

1,394

3 4 56

elevation e-01

230

S-23

S-23

FINISHES SCHEDULE

11

FIRST FLOOR PLAN

12

Client's Signature

1:100

architecture

ROOF NOTES
Stone coated Roofing sheets on
25x50mm timber battens on
secondary and primary100x50mm timber
rafters of the timber trusses on
150x50mm timber wall plate

C D

F G

HI J

KL

N O

interior design
landscape design
engineering

ssociates

mparqt

CEILING NOTES

Jumbo Plaza. plot 2.


Parliament Avenue.
p.o box 9290. kampala. uganda

Cement screed ceiling on expanded metal lath nailed to


600x600mm c.c timber brandering anchored to the timber
truss system

+9.240m

+7.800m

ARCHITECT

+7.200m

Arch. johnpaul SSENTONGO


Reg. No.: 203, P.C No.: 1667

+6.150m
+5.650m

+256 0752 445026, +256 0701 445026

MASTER
BEDROOM

+4.550m

jp@imparqtassociates.com,
jonpo44@yahoo.com

FLOOR SLAB NOTES


200mm thick R.C Floor
slab to S.E's Details

Project Name and Address

+3.150m

PROPOSED RESIDENTIAL HOUSE TO BE


BUILT AT BLOCK 192,
PLOT 562 , BUWAATE, KYADONDO
COUNTY - KIRA TOWN COUNCIL,
WAKISO DISTRICT

+2.650m

ENTRY
HALLWAY

STAIR CASE NOTES


R.C Stair case to S.E's Details

LIVING
ROOM

0.000m
-0.450m

Drawing Title
CONSTRUCTION
DRAWINGS

FLOOR NOTES
FOUNDATION NOTES
All Foundations are to S.E's
Details

SECTION X-X

Indicated floor finish on 25mm cement screed on


100mm thick oversite concrete on
1000gauge DPM on
Sand blinding on hardcore on well rammed earth

Sheet

Scale

1:100

AS SHOWN

Date

DEC 2013

KRS/BWT
L[--]02

Drawn by;

T.HENRY

Design by

T.HENRY

Notes:-

12

11

10 9 8 7

65 4 3

O N

LK

J I

G F

D C

1. All dimensions to be checked on site, written


dimensions to be followed in preference to scaled
dimensions.

2. All walls less than 200mm thick to be reinforced


with hoop iron at every alternate course.
3. All reinforced concrete work is to be in
accordance with structural engineer's details.

+9.590m

4. All sanitary work to be in accordance with M.O.H


rules and regulations.

Clay fired
roofing tiles
on timber
trusses

+8.665m
+7.930m

+9.240m

5. Where drain passes under building or driveway area,


pipe to be of cast iron or encased in 150mm concrete.

Clay fired roofing tiles on timber


trusses

6. All waste pipes and soil pipes are to be in ducts and


the bends to have all cleaning eyes accessible from
outside.

+7.800m

+7.320m

+7.200m

7. All windows and external glazed doors on ground


floor to have burglar proofing to Architect's detail.

+6.000m

+6.150m

+5.400m

+5.650m

+3.000m
+2.500m

10. All internal plaster to be two coats steel float


finished.

+3.150m

11. All manholes within building area, driveway and


parking to have heavy duty air tight covers and double
sealed.

+2.650m

Stone cladding on
brick wall on R.C
column
0.000m
-0.450m

0.000m
-0.450m

ELEVATION E-01

9. Stair case and lobby doors to be self closing and


1/2 hour fire resistant.

+4.550m

25mm Plaster
on block
wall painted
to approval

+3.600m

8. All door frames to be rebated & moulded & be full


width of wall with moulded architrave to detail,
provide rubber door stops to all doors.

250mm high
Plaster ribbons
with 50mm high
groves painted to
approval

25mm Plaster on
block wall painted
to approval

12. Provide G.I. 125 x 100 rainwater down pipes and


125 x 100 G.I.box gutter with brackets etc. where
shown.
13. All painting to be 3 coats.
14. Splash apron of 1000mm along the perimeter of
building.

1:100

ELEVATION E-02

1:100

15. Samples of fittings, materials etc. to be produced


&
approved before commencing work.
16. All windows to have P.C. cills, built in reinforced
concrete Pelmet boxes & timber internal window cills
& Skirtings.
17. Steel trusses/portal frames & purlins to be
painted with 2 coats of oil paint.
18. Fire fighting equipment to be provided and
installed by Building Fire Consultants where shown
on plan.

3 4 56

7 8 9 10

11

12

C D

F G

I J

KL

N O

19.These architectural drawings shall be read in


conjunction with the Structural
drawings,Electrical-Mechanical drawings Bills of
Quantities & Technical Specifications. Any discrepancy
shall be reported immediately to the Architect.

20. The Architect shall not accept any liability for


works which he has not been expressly instructed to
Supervise in writing and has accepted to proceed in
writing, or for any ommissions or deviations from his
drawings/technical specifications. Nor shall he take
responsibility for works handled by other nominated
Consultants or Contractors

Clay fired roofing tiles on timber


trusses

+9.240m
+9.240m

Clay fired
roofing tiles
on timber
trusses

+7.800m
+7.200m

Approved Stack
stone cladding on
block walls to
approval

+7.800m
+7.200m

+6.150m
+5.650m

+3.150m
+2.650m

Date

Revision/Issue

+6.150m

+5.650m

+4.550m

No.

25mm
Plaster on
block wall
painted to
approval

Stone cladding on
brick wall on R.C
column

Owner

+4.550m

25mm Plaster on
block wall painted
to approval

+3.150m
+2.650m

Mr. and Mrs. KAMURASI


DAVID STEVEN
Mob: 0772 881 664
Client's Signature

250mm high
Plaster ribbons
with 50mm high
groves painted to
approval

0.000m
-0.450m

architecture
interior design

0.000m
-0.450m

landscape design

Approved Stack stone


cladding on
foundation walls to
approval

Approved Stack stone


cladding on block
walls to approval

ELEVATION E-03

1:100

ELEVATION E-04

1:100

engineering

ssociates

mparqt

Jumbo Plaza. plot 2.


Parliament Avenue.
p.o box 9290. kampala. uganda

ARCHITECT
Arch. johnpaul SSENTONGO
Reg. No.: 203, P.C No.: 1667
+256 0752 445026, +256 0701 445026
jp@imparqtassociates.com,
jonpo44@yahoo.com

DOOR AND WINDOW SCHEDULE


NOTATION
PARAMETERS
(WxH)

d1-pvo

d2-pvo

d3-pvo

1700 x 2550 mm

3200 x 2200 mm
(+ 3200 x300mm (Vent))

900 x 2550 mm

1200 x 2550 mm

DESCRIPTION

Double Leaf Steel


Casement Glass pane
Swinging door with a
permanent vent over

Quadra pane Double


leaf Aluminium
casement glass pane
sliding door with a
permanent vent over

Single Leaf Timber


Panel door with a
permanent vent over

Single Leaf Timber


and glass Panel door
with a glass side light
and a permanent vent
over

LOCATION

Entry Hall

Living room, study room,


Master Bedroom

Bedrooms

Stair Lobby

Washrooms

QTY

01

03

07

01

04

d4-pvo

d5
800 x 2550 mm
Single Leaf Timber
Panel door with a
fixed glasslight
pane over

d6-pvo

d7-pvo

900 x 2500 mm

900 x 2550 mm

Single Leaf Timber


Casement Glass pane
Swinging door with a
permanent vent over

Single Leaf steel pane


and plate door with a
permanent vent over

Kitchen, Master Bedroom


06

w1-pvo
1200 x 1550mm
Double Pane aluminium
casement glass pane
sliding window with a
permanent vent over

w2-pvo
600 x 1550 mm
aluminium casement
glass pane awning
window

Rear Exit

Bedroom

Washrooms, Kitchen,
Walk-in-Closet, Staircase

01

02

13

w3-pvo
1500 x 1550 mm
Double Pane aluminium
casement glass pane
sliding window with a
permanent vent over

Bedrooms, laundry
04

w4-pvo

w5-pvo

1000 x 1850 mm

2000 x 1850 mm

aluminium casement
glass pane strip
window with awning
window panes

aluminium casement
glass pane strip
window with awning
window panes

w6-pvo
800 x 5350 mm

w7

w8-pvo

1600 x 2100 mm

600 x 900 mm

w9-pvo
1200 x 1550mm

aluminium casement
glass pane strip
window with awning
window panes

aluminium casement
glass pane window
with awning window
panes

aluminium casement
glass pane awning
window

Double Pane aluminium


casement glass pane
sliding window with a
permanent vent over

Entry Hall

Washrooms

Bedroom

Dining

Dining

Living room, Master


Bedroom

01

01

04

01

02

02

Project Name and Address

PROPOSED RESIDENTIAL HOUSE TO BE


BUILT AT BLOCK 192,
PLOT 562 , BUWAATE, KYADONDO
COUNTY - KIRA TOWN COUNCIL,
WAKISO DISTRICT
Drawing Title

Sheet

CONSTRUCTION
DRAWINGS
Scale

AS SHOWN

Date

DEC 2013

KRS/BWT
L[--]03

Drawn by;

T.HENRY

Design by

T.HENRY