You are on page 1of 4

SKF TMJG 100D

High Precision Digital Gauge


Instructions for use
1. Application
The high precision digital gauge TMJG 100D has been specially
designed to accurately measure the hydraulic pressure when mounting
bearings with the SKF Drive-up program.
The gauge is also suitable for other applications where the pressure has
to be determined with a high accuracy up to pressures of 100 MPa.
2. Description
The TMJG 100D uses the principle of a piezo-electric element which
generates a pressure related voltage.
This signal is converted by the electronics of the instrument into a digital
read out.
The unit is equipped with a special peak function for the possibility of
measuring very sudden pressure peaks.
It fits the SKF pumps 729124, TMJL 50 and TMJL 100 but can also be
connected directly to an SKF hydraulic nut type HMV.
3. Technical data
Connection thread : G 1/4
Measuring range : 0-100 MPa
Resolution : 0,1 MPa
Accuracy : 0 - 70 MPa 0,14 MPa
70 - 100 MPa 0,50 MPa
Response time : 99% in 0,001 s
Sensor : Piezo-electric element
Operating temperature : 10-50C (50-122F)
Functions : ON/OFF with automatic switch off
after 10 minutes
PEAK for indication of sudden pressure
peaks
Battery type : 9 V IEC 6LR61
Battery life : 100 hours (continuous operation)
2 SKF TMJG 100D
4. Operating instructions
1. Screw the gauge into the pressure port.
2. Adjust the face of the gauge to the preferred position by loosening
the counter-nut (fig. 1) between the housing and the shaft.
3. Turn the dial of the gauge to the preferred position (fig.2). The dial
can be rotated over 355.
4. Switch the unit ON by pressing the ON/OFF button.
5. The unit is switched off by pressing the ON/OFF button once more or
automatically after 10 minutes of use.
Figure 1
Figure 2
SKF TMJG 100D 3
6. To facilitate measurements of sudden pressure peaks the units is
supplied with a special PEAK function. The exact function of the
PEAK function is explained in fig. 3. The PEAK function is confirmed
on the display.
Note
1. Due to internal signal noise the peak reading at zero pressure will be
around 2 MPa.
2. If the maximum pressure of 100 MPa exceeded the figure 1 will be
shown on the left hand side of the display.
WARNING!
For safety reasons never apply pressures above 100 MPa.
5. Maintenance
Replace the battery as soon as Battery low is displayed on the gauge.
The instrument is then opened by simply turning the dial face beyond
the limit stop.
6. Accessories
Designation Description
TMJG S76 Rubber protection sleeve
M
P
5
3
7
E
In line with our policy of continuous development of our
products we reserve the right to alter any part of the above
specification without prior notice.
Although care has been taken to ensure the accuracy of
this publication, SKF does not assume any liability for errors
or omissions.
SKF Maintenance Products
Copyright SKF 2001/08 www.mapro.skf.com
Display digitally
frozen (Hold)
Display: highest
value drops with
2 digits/sec.
= 20 digits
= 20 digits
= 20 digits
Switch
point
Pressure profile
(Display in Normal
Operation)
Switch Point
Display value in the
PEAK-mode
Figure 3