You are on page 1of 94

50 Hz

www.francoferrucci.com

BELGIUM

ITALY

UNITED ARAB EMIRATES

Pentair Water

Pentair Pumps

Pentair Water Middle East

Industriepark Wolfstee,
Toekomstlaan 30
B-2200 HERENTALS
Tel. +32.14.25.99.11
Fax. +32.14.25.99.75
www.pentairwater.com

Via Masaccio, 13
56010 Lugnano (Pisa)
Tel. +39.050.71.61.11
Fax. +39.050.70.31.37
www.nocchi.it

Al Diyaffa Center, M Floor Office 104-105


P.O. Box 24670
Dubai, U.A.E.
Tel. +971.43.45.50.74
Fax. +971.43.45.51.04
www.pentairwater.com

Pentair Pumps
BP 92 Vedne - 84965
LE PONTET Cedex - AVIGNON
Tel. 04.90.480.880
Fax 04.90.480.888
www.nocchi.it

Pentair Water
140, avenue Roland Garros
78532 BUC CEDEX
Tel. +33.(0)1.39.24.15.00
Fax. +33.(0)1.39.56.03.90
www.pentairwater.com

GERMANY
Pentair Water
Wiesenstrae 6
Industriegebiet Nord
D-64347 Griesheim
Tel. +49615584170
Fax +496155841799

Via Brughiera 1 - 20010


PREGNANA MILANESE (MI)
Tel. +39.02.93.27.111
Fax. +39.02.93.27.1154
www.pentairwater.com

REPUBLIC OF SOUTH AFRICA


Pentair Water
P.O. Box 11325, Selcourt 1567,
15 Miller Road,
Nuffield, Springs - Gauteng
Tel. +27.11.818.5818
Fax +27.11.818.3710

RUSSIA
Pentair Pumps
4 Luchevoy Prosek
Exhibition Centre Sokolniki
Pav. 5, Off. 30 - Moscow
Tel.+7-095-913 90 22, 956 55 61
Fax +7-095-234 23 50
www.nocchi.ru

UNITED KINGDOM
Pentair Water Filtration
Daimler Drive, Cowpen Lane
Industrial Estate
Billingham - Cleveland, TS23 4DJ
Tel. +44 (0)1 642 370 616
Fax +44 (0)1.642.564.708

SPAIN
Pentair Water
MI I Fontanals 28, 08205
Sabadell - Barcelona
Tel +34 937 10 28 39
Fax +34 937 10 47 67

GB- 3 EDIZIONE 072006 - COD - NV260PB40

FRANCE

Pentair Water

Circulating pumps Catalogue

Circulating pumps Catalogue

Premier supplier of water equipment

Pentair is a diversified operating company headquartered in Minnesota.


Its Water Group is a global leader in providing innovative products and
systems used worldwide in the movement, treatment, storage and
enjoyment of water.
Pentairs Enclosure group is leader in the global market of enclosures
for sensitive electronics and electrical components.
Pentair is a values-driven company that brings superior products to
customers through some of the worlds leading brands. Efforts in
continuous improvement, strong new product development, high
performance, competence, business ethics and market leadership
have contributed greatly to our success. Pentairs employees share
many personal values such as accountability, deep respect for people
and the environment, and a candid and practical work style.
Strong customer relationships and quality products allow Pentair Water
to attain the vision of being the leading provider of water equipment.

Safe, clean water for people to drink and


enjoy, and for industries to use
Pentair Water is playing a key role in making safe, clean water available
to an ever-growing portion of the worlds population: a valuable
organization is engaged to successfully serve our customers trough
superior, decentralized and accountable operations and dedicated sales
and marketing networks.

Pentair Water operates through an organization that includes


4 Business Units:

Pump Systems

Water Treatment

Products range from single and


multistage centrifugals to
shallow and deep well
submersibles for residential,
commercial and agriculture
applications; sump, effluent and
sewage pumps designed for
water and wastewater
applications; pressure boosting
and fire fighting systems as well
as circulating pumps for heating,
ventilation and air conditioning.

Residential, commercial,
industrial, water conditioning
control valves, fiberglass wound
pressure tanks and vessels, brine
cabinets and storage tanks.

Pool and spa


Filtration & purification
Technologies
Residential, commercial, and
industrial filtration housings;
replaceable cartridge elements;
carbon block filtration; drinking
water filtration system
components; pumps for
recreational vehicles, marine,
industrial applications and food
service.

A complete line of commercial


and residential pool/spa
equipment and accessories
including pumps, filters,
heaters, lights, automation,
automatic pool cleaners,
commercial deck equipment,
barbeque deck equipment,
aquatic pond products and
accessories, pool tile and
interior finishing surfaces,
maintenance equipment,
spa/jetted tub hydrotherapy
fittings and pool/spa accessories.

Water Energy

Reliable pumps providing water


energy.
Established in 1977, Nocchi is today a part of Pentair
Water group. For more than 25 years we have been
designing and manufacturing water pumps providing
our customers quality products and concrete solutions.
Nocchi line is dedicated to engineering firms and
plumbing and heating/cooling distributing centres.
Within the full Nocchi range a professional customer
can find products and innovative solutions to suit any
need with regards to water supply and pressurization
in the realm of residential and commercial building,
irrigation and industry applications.

Heating, ventilation
and air-conditioning
Circulator pumps for circulation of hot water in central
heating systems and circulation in domestic hot water
service systems. Pumps for circulation of cold water
and other liquids in cooling and air-conditioning systems.

Pressure boosting and fire fighting


Vertical and horizontal centrifugal pumps.
Multiple pump units for transfer and boosting of water.
Fire-fighting systems.

Sewage and wastewater


Drainage, effluent and sewage pumps, for a wide range
of applications in building services.

Domestic water supply


Submersible pumps, jet pumps, multistage centrifugal
pumps and compact systems for water and rain water
supply in home and garden applications.

Groundwater supply
Submersible pumps for groundwater supply, irrigation
and groundwater lowering.

INDEX
50 Hz
Circulating pumps
SR3

REPLACEMENT PUMP HEAD SR3 - RM4

R2S

R2SD

12

R2X - R2B

16

R2C - R4C

20

R2CD - R4CD

32

R2T - R4T

44

R2TD - R4TD

56

A2L - A4L

68

A2LD - A4LD

78

ACCESSORIES

86

HOW TO CHOOSE PIPE UNIONS AND COUNTERFLANGES

87

SR3
SR3 CIRCULATING PUMPS

Variable speed pumps of the wet runner type are suitable for the circulation of water
in both individual and communal heating systems.

3 SPEED
MANUAL EXTERNAL RELEASE

Applications

Usage limitations

- Civil and industrial pressurized or open


tank heating systems

- Non-aggressive and non-explosive clean


liquids free of suspended solid particles
and fibres
- Permissible fluids (SR3 25/70):
water and water/glycol mixtures in a
ratio up to 1:1.Glycol mixtures
require a reassessment of pump
hydraulic data in line with the increased
viscosity and depending on mixing
ratios.
- Liquid temperature:
from +10 C to +110 C
from -10 C to +110 C (SR3 25/70)
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point
to avoid cavitation: 14 m (at a water
temperature of 110 C)
- The pump must be installed with the
driving shaft in horizontal position (see
drawing below)
- Threaded ports

Motor
- Wet runner with internal separator
sleeve
- Asynchronous single phase with
3 speed operation
- Provided with built in capacitor
- Class H insulation
- Level protection IP 44
- Power supply voltage: single phase
1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise
(motor end view)

DESIGN FEATURES
Component

Material

Pump body

EN-GJL-200 (ex G20) cast iron


Technopolymer
X CrNiMo 17-12-2 ( AISI 316 ) stainless steel

Impeller
Motor sleeve and guide ring
Shaft
Stator casing

X 30 Cr 13 mild steel with hard chrome plating

Thrust bearing

Graphite/Ceramic
Steel with nickel plating

Pump bearing

Aluminium

SR3
Performance range
H
[m]
10

6
SR3 15/25/32-50

4
SR3 15/25/32-60

SR3 25-70
SR3 15/25/32-40

1
0,8

0,4

0,1
0,6

10

Q [m3/h]

SR3

0,3

SR3

MY0708KKK SR3 15/40 1 - 130


1 x 230 1"
MY0700KKK SR3 25/40 1 1/2 - 130 1 x 230 1"1/2
MY0701KKK SR3 25/40 1 1/2 - 180 1 x 230 1"1/2

130
130
180

MY0715KKK SR3 32/40 2 - 180

1 x 230

2"

180

MY0707KKK SR3 15/50 1 - 130

1 x 230

1"

130

MY0705KKK SR3 25/50 1 1/2 - 130 1 x 230 1"1/2

130

MY0706KKK SR3 25/50 1 1/2 - 180 1 x 230 1"1/2

180

MY0714KKK SR3 32/50 2 - 180

1 x 230

2"

180

MY0709KKK SR3 15/60 1 - 130

1 x 230

1"

130

MY0710KKK SR3 25/60 1 1/2 - 130 1 x 230 1"1/2

130

MY0711KKK SR3 25/60 1 1/2 - 180 1 x 230 1"1/2

180

MY0713KKK SR3 32/60 2 - 180

180

2"

1 x 230

MY0717KKK SR3 25/70 1 1/2 - 180 1 x 230 1"1/2

F.

180

2,0

2,5

2,8

3,5

Motor
power

71

0,30 1950

2
1

55

0,24 1550

40

0,18 1150

104

0,45 1850

78

0,35 1400

56

0,26

110

0,48 1800

83

0,37 1400

60

0,27 1050

150

0,67 2230

2
1

132
101

0,62 1800
0,5 1290

N Q
Amp. (min
-1
)

950

10

20

30

40

50

60

70

m3/h 0,6

1,2

1,8

2,4

3,0

3,6

4,2

3,7
3,1
1,9

3,0
2,2
1,0

2,2
1,2

1,4
0,2

0,5

5,4
4,0
2,4

4,5
3,0
1,2

3,5
1,8
0,2

2,6
1,0

1,6

0,8

5,5
4,5
2,8

4,9
3,5
1,6

3,8
2,2
0,5

3,2
1,3

2,4
0,4

1,5

L/1'

Discharge
head head
Discharge
in meters
in meters

VOLT.

SPEED

MODEL

Centre
distance
(mm)

CODE

Connections

PUMP PERFORMANCE

0,5

6,57 6,15 5,63 5,06 4,44 3,73 2,82


6,16 5,52 4,69 3,77 2,8
4,61 3,36 2,09 1,16

Pipe fittings not included

DIMENSIONS AND WEIGHTS


Dimensions mm.

Connect
B

Packing
volume
(dm3)

130

65

105,4

135

46,6

76,7

2,75

SR3 25/40 1 1/2 - 130 1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/40 1 1/2 - 180 1 1/2

180

90

105,4

135

46,6

76,7

3,55

Model

SR3 15/40 1 - 130

SR3 32/40 2 - 180

180

90

105,4

135

46,6

76,7

3,55

SR3 15/50 1 - 130

130

65

105,4

135

46,6

76,7

2,75

SR3 25/50 1 1/2 - 130 1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/50 1 1/2 - 180 1 1/2

180

90

105,4

135

46,6

76,7

3,55

SR3 32/50 2 - 180

180

90

105,4

135

46,6

76,7

3,55

SR3 15/60 1 - 130

130

65

105,4

135

46,6

76,7

2,75

SR3 25/60 1 1/2 - 130 1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/60 1 1/2 - 180 1 1/2

180

90

105,4

135

46,6

76,7

3,55

SR3 32/60 2 - 180

180

90

105,4

135

46,6

76,7

2,75

180

90

121,6

145,5

49

76,7

3,6

SR3 25/70 1 1/2 - 180 1 1/2

Weight
(Kg)
net gross

2,7

2,8

2,7

2,8

2,8

2,9

3,4

3,5

SR3
TABLE OF HYDRAULIC PERFORMANCE
H (m)

P (kPa)

70

SR3 15/25/32-40
6

60

50

40

30

20

10

0
0

0
5 (m3/h)

(l/sec.)

0,5

H (m)

P (kPa)

60

SR3 15/25/32-50
5

50

40

30

20

10
0
5 (m3/h)

0
0

2
0,5

(l/sec.)

SR3

SR3
TABLE OF HYDRAULIC PERFORMANCE
H (m)

P (kPa)

70

SR3 15/25/32-60
6

60

50

40

30

20

10

0
0

0
5 (m3/h)

(l/sec.)

0,5

H (m)

P (kPa)

70
SR3 25-70

60

50

40

30

20
10

1
0
0

2
0,5

5
1

0
6 (m3/h)
2 (l/sec.)

SR3 - RM4
REPLACEMENT PUMP HEAD SR3 - RM4

SR3 MULTIHEAD
Multihead is the motor head equipped with impeller for SR3 circulating pumps. Anticlockwise rotating direction.

GASKET
KIT A

GASKET
KIT B

RM4 MOTORHEAD
RM4 Motorhead is the motor head equipped with impeller with clockwise rotating direction.

CODE

MODEL

VOLTAGE

MY0712KKK

MULTI HEAD SR3

1 x 230 V

2,8

MY0716KKK

RM4 MOTORHEAD

1 x 230 V

2,5

SPEED
3
2
1
4
3
2
1

Motor
power
w

Amp.

n (min -1)

110
74
44
110
83
60
44

0,48
0,32
0,19
0,46
0,37
0,27
0,19

1800
1200
700
1800
1400
1050
700

* Clockwise rotating direction (motor side)


Anticlockwise rotating direction (motor side)
7

SR3 - RM4

PUMP PERFORMANCE

R2S
R2S CIRCULATING PUMPS

Variable speed pumps of the wet runner type are suitable for the circulation of water
in both individual and communal heating systems.

Applications

Usage limitations

- Civil and industrial pressurized or open


tank heating systems

- Non-aggressive and non-explosive clean


liquids free of suspended solid particles
and fibres
- Liquid temperature:
from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point
to avoid cavitation: 2 m (at a water
temperature of 90 C)
- The pump must be installed with the
driving shaft in horizontal position

R2S

Motor
- Wet runner with internal separator
sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
and thermal protection
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase
1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise
(motor end view)

R2S...F

DESIGN FEATURES
Component

Material

Pump body
Impeller
Motor sleeve and guide ring

EN-GJL-200 ( ex G20 ) cast iron


X5 CrNi 1810 ( Aisi 304 ) stainless steel
X5 CrNi 1810 ( Aisi 304 ) stainless steel

Shaft

X 17 CrNi 16-2 ( AISI 431 ) stainless steel

Stator casing

Aluminium

Thrust bearing
Pump bearing

Ceramic
Graphite

R2S
Performance range
H
[m]
10
8
6

R2S 32-90

4
R2S 32-60
R2S 40-90
R2S 42-90 F

R2S 40-60
R2S 42-60 F
0,4

0,2
2

10

Q [m3/h]

R2S

1,2

R2S
F.

N8010000

R2S 32 - 60

1 x 230

2"

180

5,0

N8010001

R2S 32 - 90

1 x 230

2"

180

5,0

N8010002

R2S 40 - 60

1 x 230

2"

180

5,0

N8010003

R2S 40 - 90

1 x 230

2"

180

7,0

N8010004

R2S 42 - 60 F

1 x 230

D N 40
250
PN 6

5,0

N8010005

R2S 42 - 90 F

1 x 230

D N 40
250
PN 6

7,0

Motor
power

3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1

143
121
110
231
198
181
165
159
143
275
253
187
165
159
143
275
253
187

Amp.
(A)

0,8
0,7
0,6
1,1
0,9
0,8
0,9
0,8
0,7
1,2
1,1
0,9
0,9
0,8
0,7
1,2
1,1
0,9

Rpm Q
(min-1)

2600
2300
1500
2600
2100
1400
2700
2400
1550
2600
1900
1300
2600
2300
1600
2250
1800
1600

20

30

40

60

80

m /h 1,2

1,8

2,4

3,6

4,8

4,7
4,5
4,2
7,8
6,8
4,7
4,9
4,7
4,0
8,3
5,0
3,4
4,9
4,7
4,0
7,9
6,7
3,8

4,4
4,0
3,4
7,3
6,0
3,21
4,7
4,4
3,6
7,8
3,9
2,3
4,6
4,3
3,6
7,5
5,7
2,9

4,2
3,6
3,0
6,6
4,9
2,0
4,4
4,1
3,2
7,5
3,0
1,7
4,4
4,0
3,2
7,1
4,7
2,0

2,9
2,3
1,6
4,8
2,6
0,4
3,9
3,4
2,5
6,5
1,7
1,0
3,8
3,3
2,2
6,4
2,8
1,2

1,8

L/1'
3

Discharge head
in meters

VOLT.

SPEED

MODEL

Centre
distance
(mm)

CODE

Connections

PUMP PERFORMANCE
100 150
6

2,6
0,2

0,2

3,3
2,8
1,8
5,6
1,2
0,8
2,9
2,4
1,3
5,5
1,4
0,7

2,4
2,1
1,2
4,7
0,9
0,4
2,0
1,5
0,2
4,4
0,8
0,4

9,0

2,4

1,4

Pipe fittings and counterflanges not included

R2S 42

R2S 32 - 40

DIMENSIONS AND WEIGHTS


Model

Dimensions mm.

connect.
A

Packing
volume
(dm3)

Weight (Kg)
net

gross

R2S 32 - 60

180

90

125

165

120

100

4,8

5,0

R2S 32 - 90

180

90

125

165

120

100

4,8

5,0

R2S 40 - 60

180

90

135

175

120

100

5,3

5,5

R2S 40 - 90

180

90

135

175

120

100

5,3

5,5

250

125

135

190

120

100

11

7,5

7,7

250

125

135

190

120

100

11

7,5

7,7

DN 40
PN 6
DN
40
R2S 42 - 90 F
PN 6
R2S 42 - 60 F

10

Optional
accessories

Pipe fitting kit

R2S
TABLE OF HYDRAULIC PERFORMANCE
P01024244 / 10.07.01

P (kPa)

70

R2S 32-60
6

60

50
40

H (m)

P01024547 / 11.07.01

10
9

R2S 32-90

80

70

60

30

20

10

0
0

0,5

H (m)

1,5

30

0,5

0
6 (m3/h)

H (m)

1,5

P01019193 / 08.05.01

10

R2S 40-90

10
0
0
0

2
0,5

4
1

6
1,5

H (m)

8
2

9
2,5

P19701.3V / 30.07.01

R2S 42-60F

70
60

50
40

30

20
10

(l/sec.)

P (kPa)

H (m)

50

40

30

20

10

0
0

0,5

4
1

6
1,5

0
10 (m3/h)

8
2

2,5

(l/sec.)

0,5

1,5

2,5

0
10 (m3/h)
(l/sec.)

P (kPa)

P010273 / 19.07.01

90

R2S 42-90F

80

70
60

10 (m3/h)

60

100
90
80

P (kPa)

20

(l/sec.)

10

40

20

50

30

(l/sec.)

R2S 40-60

40

60

50

6 (m3/h)

P (kPa)

P010241 / 10.07.01

100
90

P (kPa)

50

40

30

20

10

0
0
0

0,5

4
1

11

6
1,5

8
2

9
2,5

0
10 (m3/h)
(l/sec.)

R2S

H (m)

R2SD
R2SD TWIN HEAD CIRCULATING PUMPS

Variable speed pumps of the wet runner type are suitable for the circulation of water
in both individual and communal heating systems.

Applications

Usage limitations

- Civil and industrial pressurized or open


tank heating systems

- Non-aggressive and non-explosive clean


liquids free of suspended solid particles
and fibres
- Liquid temperature:
from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point
to avoid cavitation: 2 m (at a water
temperature of 90 C)
- The pump must be installed with the
driving shaft in horizontal position
- Series 32 threaded ports
Series 42 flanged ports

Motor
- Wet runner with internal separator
sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase
1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise
(motor end view)

DESIGN FEATURES
Component

Material

Pump body
Impeller
Motor sleeve and guide ring

EN-GJL-200 ( ex G20 ) cast iron


X5 CrNi 1810 ( Aisi 304 ) stainless steel
X5 CrNi 1810 ( Aisi 304 ) stainless steel

Shaft

X 17 CrNi 16-2 ( Aisi 431 ) stainless steel

Stator casing

Aluminium

Thrust bearing
Pump bearing

Ceramic
Graphite

12

R2SD
Performance range
H
[m]
10

R2SD 32-90
R2SD 42-90 F
5

3
R2SD 32-60

R2SD 42-60 F

1
2

10

Q [m3/h]

R2SD

1,2

13

R2SD

N8010006

R2SD 32 - 60

1 x 230

2"

180

N8010007

R2SD 32 - 90

1 x 230

2"

180

N8010008

R2SD 42 - 60 F

N8010009

R2SD 42 - 90 F

MODEL

VOLT.

DN40
1 x 230 PN6 255
PN10
DN40
1 x 230 PN6 255
PN10

Motor
power

3
2
1

143
121
110
231
198
181
165
159
143
275
253
187

3
2
1
3
2
1
3
2
1

n Q
Amp. (min
-1
)

0,8
0,7
0,6
1,1
0,9
0,8
0,9
0,8
0,7
1,2
1,1
0,9

2600
2300
1450
2600
2000
1400
2400
1800
1150
2400
1600
1100

20

30

40

60

80

m /h 1,2

1,8

2,4

3,6

4,8

L/1'
3

Discharge head
in meters

Centre
distance
(mm)

F.

CODE

SPEED

Connections

PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION


100 150
6

5,2
4,8
4,5

4,8
4,5
4,0

4,4
4,0
3,5

3,0
2,6
2,0

0,9
0,6

8,0
7,0
4,8
5,1
4,8
4,1
7,7
6,3
3,6

7,5
6,1
3,4
4,9
4,5
3,6
7,4
5,2
2,7

6,9
5,0
2,2
4,6
4,2
3,1
7,1
4,1
2,0

5,4
2,8
0,8
4,0
3,4
2,1
6,4
2,3
1,1

3,2
0,9

1,0

3,2
2,4
1,3
5,5
1,2
0,7

2,1
1,4
0,6
4,4
0,7

9,0

1,2

Pipe fittings and counterflanges not included

R2SD 32

R2SD 42

DIMENSIONS AND WEIGHTS


Model

Dimensions mm.

Connect
A

Packing
volume
(dm3)

Weight (Kg)
net

gross

R2SD 32 - 60

180

105

135

175

235

100

14,2

9,9

10,1

R2SD 32 - 90

180

105

135

175

235

100

14,2

9,9

10,1

R2SD 42 - 60 F DN 40

250

145

135

195

245

100

21,5

15,7

15,9

R2SD 42 - 90 F DN 40

250

145

135

195

245

100

21,5

15,7

15,9

14

Optional
accessories

Pipe fitting
kit

R2SD
TABLE OF HYDRAULIC PERFORMANCE
H (m)

P22601b / 07.09.01

R2SD 32-90

P (kPa)

90

80

70

H (m)

P230001b / 07.09.01

60

R2SD 32-60
5

60

50

40

50
40

30

20

10

30

20

1
0
0

0
6 (m3/h)

0,5

1,5

0
0

(l/sec.)

(l/sec.)

With only one head in operation

H (m)

P (kPa)

P22302b / 31.08.01

60

R2SD 42-60F
5

50

40

H (m)

P22301e / 28.08.01

R2SD 42-90F

80

70

60
50

30

4
20

10

0
0
0

2
0,5

4
1

With only one head in operation

6
1,5

7
2

40
30

2
1

90

20
10

1
0

8 (m3/h)

(l/sec.)

4
1

0,5

6
1,5

8
2

0
9 (m3/h)
2,5 (l/sec.)

With only one head in operation

R2SD

P (kPa)

10
0
5 (m3/h)

0,5

With only one head in operation

P (kPa)

15

R2X - R2B
R2X - R2B CIRCULATING PUMPS FOR
DOMESTIC WATER

Circulating pumps of the wet runner type are suitable for the
circulation of hot sanitary water in heating systems.

R2X WITH STAINLESS STEEL PUMP CASING


R2B WITH BRONZE PUMP CASING

Applications

Usage limitations

- Sanitary hot water circulation systems,


heating and conditioning systems

- Non-aggressive and non-explosive clean


liquids free of suspended solid
particles and fibres
- Lime-stone free water
(if water exceeds 35 F a softener
device must be installed)
- Suggested water temperature
max 60 C
- The pump must be installed with the
driving shaft in horizontal position
(see picture below)

Motor
-

Wet runner with liner


Asynchronous single phase
One speed operation
Provided with built in capacitor
Class F insulation
Level protection IP 42
Power supply voltage: single phase
1 x 230 V - 50 Hz
- Direction of rotation (motor end view):
R2X series anticlockwise
R2B series anticlockwise

DESIGN FEATURES
Material
Component

Series R2X

Series R2B

Pump casing AISI 304 stainless steel in Al casing B10 bronze ( G CuSn 10 )
X5 CrNi 1810 (AISI 304)stainless steel X5 CrNi 1810 (AISI 304)stainless steel
Impeller
Motor sleeve X5 CrNi 1810 (AISI 304)stainless steel X5 CrNi 1810 (AISI 304)stainless steel
Seal ring

X5 CrNi 1810 (AISI 304)stainless steel X5 CrNi 1810 (AISI 304)stainless steel

Shaft

X17 CrNi 16-2 (AISI 431)stainless steel X17 CrNi 16-2 (AISI 431)stainless steel

Stator casing Aluminium

Aluminium

Pump bearing Graphite

Graphite

Thrust bearing 99% alumina B

99% alumina B

16

R2X - R2B
Performance range
H
[m]
10

R2B 32-90
R2B 30-90

R2B 40-60

R2B 40-90

R2B 32-60
R2B 30-60

R2X 20-30

R2X 20-18
1

0,2
1

10

3
20 Q [m /h]

R2X - R2B

0,6

17

R2X - R2B
Centre
distance
(mm)

F.

SPEED

Connections

PUMP PERFORMANCE
Motor
power

B1641600

R2X 20 - 18

1 x 230 1" 1/4

150

3,0

75

0,36

2200

1,7

1,3

0,7

B1643600

R2X 20 - 30

1 x 230 1" 1/4

150

3,0

87

0,42

2000

2,6

2,0

1,3

0,3

N8010014

R2B 30 - 60

180

5,0

130

0,7

2600

5,3

4,9

4,6

4,1

3,5

2,7

0,5

180

5,0

210

2600

8,2

7,6

7,1

6,6

6,0

5,2

3,0

MODEL

N8010010

R2B 32 - 60

N8010015

R2B 30 - 90

VOLT.

n Q
Amp. (min
-1
)

1" 1/2
1 x 230
1 x 230

2"
1" 1/2

10

20

30

40

50

60

80

m3/h 0,6

1,2

1,8

2,4

3,0

3,6

4,8

L/1'

Discharge head
in meters

CODE

N8010011

R2B 32 - 90

N8010012

R2B 40 - 60

1 x 230

2"

180

5,0

150

0,8

2700

5,3

5,0

4,8

4,5

4,2

3,8

3,2

N8010013

R2B 40 - 90

1 x 230

2"

180

7,0

250

1,1

2600

7,6

7,2

6,8

6,4

6,1

5,8

5,1

2"

Pipe fittings not included

R2X

R2B

DIMENSIONS AND WEIGHTS


Model

Dimensions mm.

Connect
A

1" 1/4

150

90

119

154

120

80

R2B 30 - 60

1" 1/2

180

90

125

165

120

R2B 32 - 60

180

90

125

165

R2B 30 - 90

1" /2

180

90

125

R2B 32 - 90

180

90

R2B 40 - 60

180

R2B 40 - 90

180

Packing
volume
(dm3)

Weight (Kg)
net

gross

4,5

2,0

2,2

100

5,1

5,3

120

100

5,1

5,3

165

120

100

5,1

5,3

125

165

120

100

5,1

5,3

90

135

175

120

100

5,6

5,8

90

135

175

120

100

5,6

5,8

Optional
accessories

R2X 20 - 18
R2X 20 - 30

18

Pipe fitting kit

R2X - R2B
TABLE OF HYDRAULIC PERFORMANCE

P (kPa)

P31001 / 08.11.01

70

R2B 30 / 32 - 60

P31101a / 07.11.01

R2B 30 / 32 - 90

60

50

H (m)

10

40

P (kPa)

100
90

80

70

60

50

30

40

20

30

20

10

10

0
0

0,5

H (m)

6 (m3/h)

5
1,5

60

R2B 40-60
50

40

4
3

30

20

10

0
0
0

2
0,5

4
1

6
1,5

8
2

9
2,5

(l/sec.)

P (kPa)

P010262 / 17.07.01

0
8 (m3/h)

0
1

0,5

1,5

H (m)

P (kPa)

P010265 / 17.07.01

(l/sec.)

90

R2B 40-90

80

70

60

50

40

30

20

10

10 (m3/h)

(l/sec.)

0,5

4
1

19

6
1,5

7
2

9
2,5

0
10 (m3/h)
(l/sec.)

R2X - R2B

H (m)

R2C - R4C
R2C - R4C CIRCULATING PUMPS

Variable speed pumps of the wet runner type are suitable for the circulation of water
in both civil and industrial heating, air-conditioning and refrigeration systems.

Usage limitations

Applications
- Pressurized or open tank heating
systems
- Air-conditioning systems
- Domestic hot water distribution systems

Motor
- With internal separator sleeve 2 poles
(R2CD) or 4 poles (R4CD)
- Two speed operation
- Provided with built in capacitor
(single phase models)
- Class F insulation
- Level of protection IP42
- Power supply voltage :
single phase 1 x 230 V - 50 Hz
three phase 3 x 230 V - 50 Hz
3 x 400 V - 50 Hz
- Direction of rotation: anticlockwise
(motor end view)

- Non-aggressive and non-explosive


clean liquids free of suspended solid
particles and fibres
- Hot water or coolants not containing
mineral oils
- Liquid temperature:
from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the
driving shaft in horizontal position
- Flanged ports:
DN 40-50-65 PN 6/10
DN 80-100
PN 6
DN 80-100
PN 10

DESIGN FEATURES
Component

20

Material

Pump casing
Impeller

EN-GJL 200 ( ex G20 ) cast iron


X5 CrNi 1810 ( Aisi 304 ) stainless steel

Motor sleeve and guide ring


Shaft

X5 CrNi 1810 ( Aisi 304 ) stainless steel


X 17 CrNi 16-2 ( AISI 431 ) stainless steel

Stator casing
Thrust bearing

Aluminium
Ceramic

Pump bearing

Graphite

R2C - R4C
Performance range

H
[m]
20
16
R2C
65 - 180

R2C
50 - 180

R2C
80 - 180

12
10
R2C
40 - 120

R2C
50 - 120
R2C
65 - 120
R2C
80 - 120

6
5

R2C
40 - 60

R2C
R4C
50 - 60

R2C
R4C
65 - 60

R4C
80 - 60

R4C
40 - 30

R4C
100 - 60
2

R4C
50 - 30

R4C
80 - 30

R4C
65 - 30

R4C
100 - 30

1
3

6 7 8

10

20

30

40

50 60

80 100

Q [m3/h]

R2C - R4C

21

R2C - R4C 40
Motor
power
W
max
min

Amp.

6/10

2
1

250
180

210
110

3 x 230

6/10

2
1

200
108

B3420350

3 x 400

6/10

2
1

B3420624

1 x 230

6/10

3 x 230

6/10

B3420600

3 x 400

6/10

2
1
2
1
2
1

B3421224

1 x 230

6/10

2
1

3 x 230

6/10

3 x 400

6/10

CODE

MODEL

B3420602

B3421202

1 x 230

VOLT.

B3420374
B3420352

PN
(bar)

R4C 40 - 30

R2C 40 - 60

R2C 40 - 120

B3421200

L/1'

n
(min-1)

F.

1,14
1,05

1450
1320

12

150
68

1,20
0,48

1410
1190

200
108

150
68

0,70
0,28

1410
1190

2
1

337
290
305
202
305
202
540
450
550
370

250
170
210
132
210
132
390
280
335
245

1,54
1,40
1,34
0,64
0,77
0,37
2,46
2,20
1,85
1,10

2760
2470
2810
2520
2810
2520
2710
2150
2710
2110

2
1

550
370

335
245

1,07
0,63

2710
2110

50

100 150 200 250 300

12

15

3,3
2,8

3,1
2,6

2,6
2,0

2,0
1,2

1,2
0,5

0,3

6,5
5,5

6,2
4,8

5,4
3,7

4,1
2,2

2,7
0,8

1,0

11,8 11,2
9,1 7,3

9,9
5,7

8,3
3,8

6,8
2,3

4,7
0,8

Q
3

m /h

Discharge head
in meters

SPEED

PUMP PERFORMANCE

12
-

18

20
-

2,2

Counterflanges not included

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1

D2

D3

D4

D5 nD5 D6 D7 nD7 H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4C 40 -

30 42

80 100 150

14

110

19

67 218 285 250 75

95

75

90

96 M12

14

16

0,030

R2C 40 -

60 42

80 100 150

14

110

19

67

95

75

90

96 M12

14

16

0,030

R2C 40 - 120 42

80 100 150

14

110

19

67 218 285 250

95

75

90

96 M12

15

17

0,030

22

218 285 250 75


75

R2C - R4C 40

R2C - R4C

TABLE OF HYDRAULIC PERFORMANCE

23

R2C - R4C 50
Motor
power
W
max
min

Amp.

2
1

275
225

235
130

3 x 230 6/10

2
1

230
132

B3520350

3 x 400 6/10

2
1

B3540674

1 x 230 6/10

F.

1,30
1,27

1380
1150

12

160
90

1,28
0,58

1390
1170

230
132

160
90

0,74
0,33

1390
1170

2
1

450
420

290
195

2,10
2,25

1380
1120

20

3 x 230 6/10

2
1

425
290

220
140

1,91
1,04

1390
1170

B3540650

3 x 400 6/10

2
1

425
290

220
140

1,10
0,60

1390
1170

B3520624

1 x 230 6/10

2
1

390
350

250
190

1,80
2,25

2700
2230

12

3 x 230 6/10

2
1

390
243

240
145

1,65
0,75

2700
2280

MODEL

B3520374
B3520352

R4C 50 - 30

B3540652

R4C 50 - 60

B3520602

R2C 50 - 60

1 x 230 6/10

3 x 400 6/10

2
1

390
243

240
145

0,95
0,43

2700
2280

B3541224

1 x 230 6/10

2
1

1020
950

620
450

4,60
4,50

2800
2500

35

3 x 230 6/10

2
1

885
650

480
370

3,02
2,04

2700
2280

R2C 50 - 120

B3541200

3 x 400 6/10

2
1

885
650

480
370

1,75
1,18

2700
2050

B3541802

3 x 230 6/10

2
1

1330
940

730
530

4,42
2,85

2700
2280

3 x 400 6/10

2
1

1330
940

730
530

2,55
1,65

2760
2260

R2C 50 - 180

B3541800

50

100 200 300 400 500

12

18

3,0
2,5

2,8
2,2

2,6
1,9

2,0
1,0

1,0
0,2

5,6

5,4

5,2

4,2

2,9

5,0

4,5

3,9

2,5

1,0

6,9

6,7
4,8

6,3
4,1

4,7
2,4

2,2
0,4

11,6 11,2 10,8

8,4

7,2

4,5

10,1

6,2

4,0

2,0

17,0 16,0 14,8 12,0


14,0 12,4 10,6 7,5

9,0
4,0

4,3

Q
3

m /h

B3520600

B3541202

L/1'

n
(min-1)

CODE

VOLT. PN
(bar)

Discharge head
in meters

SPEED

PUMP PERFORMANCE

5,2

9,1

8,5

24

30

1,0

1,4

0,2

Counterflanges not included

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1

D2

D3

D4 D5 nD5 D6 D7 nD7 H1

H2

H3

L1

B1

B2

B3

B4

B5

75

95

75

Weight (Kg) Packing


volume
(m3)
net gross

R4C 50 -

30

50

90

110 165

14

125

19

75

220 295 280

102

96 M12

17

19

0,030

R4C 50 -

60

50

90

110 165

14

125

19

75

255 330 280 101 115 101 102

96 M12

23

26

0,054

R2C 50 -

60

50

90

110 165

14

125

19

75

220 295 280

102

96 M12

17

19

0,030

R2C 50 - 120

50

90

110 165

14

125

19

75

255 330 280 101 115 101 102

96 M12

24

26

0,054

R2C 50 - 180

50

90

110 165

14

125

19

75

265 340 280 101 115 101 102

96 M12

25

28

0,054

24

75

95

75

R2C - R4C 50

R2C - R4C

TABLE OF HYDRAULIC PERFORMANCE

25

R2C - R4C 65

MODEL

VOLT.

PN
(bar)

3 x 230 6/10

B3620352
R4C 65 - 30
B3620350

3 x 400 6/10
3 x 230 6/10

B3640652
R4C 65 - 60

Motor
power
W
max
min

Amp.

2
1
2
1
2
1

305
185
305
185
540
370

210
120
210
120
280
175

1,52
0,70
0,87
0,40
2,55
1,30

1330
1010
1330
1010
1400
1190

540
370

280
175

1,47
0,55

1400
1190

B3640650

3 x 400 6/10

2
1

B3620602

3 x 230 6/10

2
1

478
328

302
208

1,70
1,02

2780
2270

B3620600

3 x 400 6/10

2
1

478
328

302
208

0,98
0,59

2780
2270

B3641202

3 x 230 6/10

2
1

1330
940

730
530

4,42
2,85

2760
2260

2
1
2
1

1330
940

730
530

2,55
1,65

2760
2260

1970
1510

950
720

6,65
4,50

2810
2420

2
1

1970
1510

950
720

3,85
2,60

2810
2420

R2C 65 - 60

R2C 65 - 120
B3641200

3 x 400 6/10

B3641802

3 x 230 6/10
R2C 65 - 180
3 x 400 6/10

B3641800

100

12

18

24

36

2,9
2,4

2,8
2,1

2,4
1,6

1,9
1,0

1,3
0,5

0,1

5,5
5,0

5,4
4,2

4,8
3,4

4,2
2,5

3,2
1,4

1,0

6,3
5,1

6,0
4,1

5,3
3,2

4,2
2,1

2,6
0,9

11,8 11,4 10,9 10,1


9,5 9,0 7,9 6,9

8,6
4,5

5,7
2,7

18,0 16,9 15,2 12,7


15,5 13,6 11,0 8,8

9,4
6,3

2,5
0,4

L/1'

n
(min-1)

200 300 400 600 800

Q
3

m /h

Discharge head
in meters

CODE

SPEED

PUMP PERFORMANCE

48

1,9

Counterflanges not included

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1

D2

D3

D4 D5 nD5 D6 D7 nD7 H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4C 65 -

30

65

110 130 185

14

145

19

82

230 312 340

75

95

75

124

96

M12

23

26

0,054

R4C 65 -

60

65

110 130 185

14

145

19

82

265 347 340

75

95

75

124

96

M12

29

32

0,054

R2C 65 -

60

65

110 130 185

14

145

19

82

230 312 340 101 115 101 124

96

M12

23

25

0,054

R2C 65 - 120

65

110 130 185

14

145

19

82

265 347 340 101 115 101 124

96

M12

30

33

0,054

R2C 65 - 180

65

110 130 185

14

145

19

82

286 368 340 101

96

M12

33

36

0,054

26

115 101 124

R2C - R4C 65

R2C - R4C

TABLE OF HYDRAULIC PERFORMANCE

27

R2C - R4C 80

PN
(bar)

Motor
power
W
max
min

3 x 230

6
10

2
1

390 270
273 185

1,82
1,00

1405
1200

R4C 80 - 30

3 x 400

6
10

2
1

390 270
273 185

1,05
0,58

1405
1200

R4C 80 - 60

3 x 230

6
10

2
1

975 470
710 290

4,75
2,50

1400
1200

MODEL

B3840352
R4C 80 - 30

B3840100

VOLT.

B3840350
B3840110
B3840652
B3840120
B3840650

Amp.

R4C 80 - 60

3 x 400

6
10

2
1

975 470
710 290

2,75
1,45

1400
1200

R2C 80 - 120

3 x 230

6
10

2
1

1970 730
1510 530

6,65
4,50

2810
2420

B3840130
B3841202
B3840140
B3841200
R2C 80 - 120

3 x 400

6
10

2
1

1970 730
1510 530

3,85
2,60

2810
2420

R2C 80 - 180

3 x 230

6
10

2
1

2520 2320
1780 1040

7,60
5,40

2800
2450

3 x 400

6
10

2
1

2520 2320
1780 1040

4,40
3,10

2800
2450

B3840150
B3841802
B3840160
B3841800
R2C 80 - 180
B3840170

100

15

30

45

3,7
3,1

3,6
2,8

3,2
2,2

1,9
0,7

0,2

6,0

5,9
5,2

5,7
4,8

4,7
3,2

2,9
0,9

0,8

11,2 11,0 10,8

9,8

7,8

5,0

10,2

6,9

4,7

2,2

L/1'

n
(min-1)

250 500 750 1000 1250

Q
3

m /h

5,4

Discharge head
in meters

CODE

SPEED

PUMP PERFORMANCE

9,6

8,8

60

75

1,3

17,8 17,5 16,7 13,1 4,6


15,2 14,6 12,8 7,4

Counterflanges not included

B2

B1

B5

D1
D2
D4

H1

D1
D2
D4

D3
D5

H2
H3

G 1/4"

B2

D3
D5

B1

B3

B4

L1

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Dimensions mm.

PN
bar

Model

D1

D2

D3

D4

D5 nD5 H1

H2

H3

L1

Weight (Kg)
B1

B2

B3

B4

B5

net

gross

Packing
volume
(m3)

R4C 80 -

30

80

128

150

190

19

97

266 363 360

101 115 101

130

96

M12

32

35

0,054

R4C 80 -

60

80

128

150

190

19

97

286 383 360

101 115 101

130

96

M12

36

39

0,054

R2C 80 - 120

80

128

150

190

19

97

286 383 360

101 115 101 130

96

M12

37

40

0,054

R2C 80 - 180

80

128

150

190

19

97

286 383 360

101 115 101

96

M12

37

40

0,054

130

DIMENSIONS AND WEIGHTS PN 10


Dimensions mm.

PN
bar

Model

D1

D2

D3

D4

D5 nD5 H1

H2

H3

L1

Weight (Kg)
B1

B2

B3

B4

B5

net

gross

Packing
volume
(m3)

R4C 80 -

30

10

80

128

160

200

19

97

266 363 360

101 115 101

130

96

M12

32

35

0,054

R4C 80 -

60

10

80

128

160

200

19

97

286 383 360

101 115 101

130

96

M12

36

39

0,054

R2C 80 - 120

10

80

128

160

200

19

97

286 383 360

101 115 101 130

96

M12

37

40

0,054

R2C 80 - 180

10

80

128

160

200

19

97

286 383 360

101 115 101

96

M12

37

40

0,054

28

130

R2C - R4C 80

R2C - R4C

TABLE OF HYDRAULIC PERFORMANCE

29

R4C 100
Motor
power
W
max
min

Amp.

n
(min-1)

2
1

669
420

495
340

2,85
1,55

1370
1130

10

2
1

669
420

495
340

2,85
1,55

1370
1130

2
1

669
420

495
340

1,65
0,90

1370
1130

B3040120

10

2
1

669
420

495
340

1,65
0,90

1370
1130

B3040652

2
1

1235
810

880
595

5,42
2,95

1375
1120

10

2
1

1235
810

880
595

5,42
2,95

1375
1120

2
1

1235
810

880
595

3,12
1,70

1375
1120

10

2
1

1235
810

880
595

3,12
1,70

1375
1120

CODE

MODEL

VOLT.

B3040352
R4C 100 - 30

3 x 230

B3040100
B3040350
R4C 100 - 30

R4C 100 - 60

3 x 400

3 x 230

B3040130
B3040650
R4C 100 - 60

PN
(bar)

3 x 400

B3040140

L/1'

250

500 750 1000 1250 1500

m3/h

15

30

45

60

75

3,7

3,4

3,0

2,3

1,4

0,1

3,0

2,6

2,0

1,2

0,1

6,0

5,7

5,2

4,7

3,8

2,6

4,6

4,2

3,5

2,7

1,6

0,3

90

Discharge head
in meters

SPEED

PUMP PERFORMANCE

1,1

Counterflanges not included

B2

B1

B5

D1
D2
D4

H1

D1
D2
D4

D3
D5

H2
H3

G 1/4"

B2

D3
D5

B1

B3

B4

L1

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Dimensions mm.

PN
bar

Model

D1

D2

D3

D4

D5 nD5 H1

H2

H3

L1

Weight (Kg)
B1

B2

B3

B4

B5

net

gross

Packing
volume
(m3)

R4C 100 -

30

100 148

170 210

19

107 305

412 450

101 115 101

167

144 M16

45

48

0,081

R4C 100 -

60

100 148

170 210

19

107 325

432 450 101 115 101

167

144 M16

46

49

0,081

DIMENSIONS AND WEIGHTS PN 10


Dimensions mm.

PN
bar

Model

D1

D2

D3

D4

D5 nD5 H1

H2

H3

L1

Weight (Kg)
B1

B2

B3

B4

B5

net

gross

Packing
volume
(m3)

R4C 100 -

30

10

100 148

180 220

19

107 305

412 450

101 115 101

167

144 M16

45

48

0,081

R4C 100 -

60

10

100 148

180 220

19

107 325

432 450 101 115 101

167

144 M16

46

49

0,081

30

R4C 100

R4C

TABLE OF HYDRAULIC PERFORMANCE

31

R2CD - R4CD
R2CD - R4CD TWIN HEAD CIRCULATING PUMPS

Variable speed pumps of the wet runner type are suitable for the circulation of water
in both civil and industrial heating, air-conditioning and refrigeration systems.

Applications
- Pressurized or open tank heating
systems
- Air-conditioning systems
- Domestic hot water distribution systems

Motor

Usage limitations

- Asynchronous wet runner with internal


separator sleeve, 2 pole (R2CD) or
4 pole (R4CD)
- Two speed operation
- Provided with built in capacitor
(single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage:
single or three phase
- Direction of rotation: anticlockwise
(motor end view)
- Power supply voltage :
single phase
1 x 230 V -50 Hz
three phase
3 x 230 V -50 Hz
3 x 400 V -50 - Hz

- Non-aggressive and non-explosive


clean liquids free of suspended solid
particles and fibres
- Hot water or coolants not containing
mineral oils
- Liquid temperature: from
-20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the
driving shaft in a horizontal position
- Flanged ports: DN 40-50-65 PN 6/10
DN 80-100
PN 6
DN 80-100
PN 10

DESIGN FEATURES
Component

32

Material

Pump casing
Impeller

EN-GJL 200 ( ex G20 ) cast iron


X5 CrNi 1810 ( Aisi 304 ) stainless steel

Motor sleeve and guide ring


Shaft

X5 CrNi 1810 ( Aisi 304 ) stainless steel


X 17 CrNi 16-2 ( AISI 431 ) stainless steel

Stator casing
Thrust bearing

Aluminium
Ceramic

Pump bearing

Graphite

R2CD - R4CD
Performance range

H
[m]
20
16
R2CD
65 - 180

R2CD
50 - 180

R2CD
80 - 180

12
10
R2CD
40 - 120

R2CD
50 - 120
R2CD
65 - 120
R2CD
80 - 120

6
5

R2CD
40 - 60

R2CD
R4CD
50 - 60

R2CD
R4CD
65 - 60

R4CD
80 - 60

R4CD
40 - 30

R4CD
100 - 60
2

R4CD
50 - 30

R4CD
80 - 30

R4CD
65 - 30

R4CD
100 - 30

1
3

6 7 8

10

20

30

40

50 60

80 100

Q [m3/h]

R2CD - R4CD

33

R2CD - R4CD 40
SPEED

PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION


Motor
power
W
max
min

2
1
2
1

210
110
150
68

1,14
1,05
1,20
0,48

1450
1320
1410
1190

2
1

250
180
200
108
200
108

150
68

0,70
0,28

1410
1190

1 x 230 6/10

2
1

337
290

250
170

1,54
1,40

2760
2470

12

B3420502

R2CD 40 - 60 3 x 230 6/10

2
1

210
132

1,34
0,64

2810
2520

B3420500

3 x 400 6/10

305
202
305
202

210
132

0,77
0,37

2810
2520

B3421124

1 x 230 6/10

540
450

390
280

2,46
2,20

2710
2150

20

B3421102

R2CD 40 - 120 3 x 230 6/10

2
1

550
370

335
245

1,85
1,10

2710
2110

B3421100

3 x 400 6/10

2
1

550
370

335
245

1,07
0,63

2710
2110

MODEL

VOLT.

PN
(bar)

B3420274

1 x 230 6/10

B3420252

R4CD 40 - 30 3 x 230 6/10

B3420250

3 x 400 6/10

B3420524

2
1
2
1

n
(min-1)

Amp.

L/1'

F.

50

100 150 200 250 300

12

15

3,3
2,8

3,1
2,6

2,6
2,0

2,0
1,2

1,2
0,5

0,3

6,5
5,5

6,2
4,8

5,4
3,7

4,1
2,2

2,7
0,8

1,0

11,8 11,2
9,1 7,5

9,9
6,1

8,3
4,2

6,8
2,2

4,7
0,2

Q
3

m /h

18

12
-

Discharge head
in meters

CODE

2,2

Counterflanges not included

B1
L4

B2

L5

B3

H2
H3

M
G 1/4
B4

D7

H1

B4

B5

D5
G1/8
D1
D2
D3

L2

L3
L1

D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1 D2 D3

D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1 L2 L3 L4 L5

B1 B2 B3 B4 B5

Weight (Kg) Pack.


vol.
(m3)
M net gross

R4CD 40 - 30

42

80 100 150 14

4 110 19

68 218 286 250 99 151 97 96 364 184 180 100 200 M12 27 30 0,054

R2CD 40 - 60

42

80 100 150 14

4 110 19

68 218 286 250 99 151 97 96 364 184 180 100 200 M12 27 30 0,054

R2CD 40 - 120

42

80 100 150 14

68 218 286 250 99 151 97 96 364 184 180 100 200 M12 29 32 0,054

34

110 19

R2CD - R4CD 40
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

R2CD - R4CD

With only one head in operation

With only one head in operation

35

R2CD - R4CD 50
Motor
power
W
max
min

1 x 230

6/10

2
1

275
225

235
130

3 x 230

6/10

2
1

230
132

B3520250

3 x 400

6/10

2
1

B3540574

1 x 230

6/10

3 x 230

B3540550

L/1'

n
(min-1)

F.

1,30
1,27

1380
1150

12

160
90

1,28
0,58

1390
1170

230
132

160
90

0,74
0,33

1390
1170

2
1

450
420

290
195

2,10
2,25

1380
1120

20

6/10

2
1

425
290

220
140

1,91
1,04

1390
1170

3 x 400

6/10

2
1

425
290

220
140

1,10
0,60

1390
1170

B3520524

1 x 230

6/10

2
1

390
350

250
190

1,80
2,25

2700
2230

12

B3520502 R2CD 50 - 60

3 x 230

6/10

2
1

390
243

240
145

1,65
0,75

2700
2280

B3520500

3 x 400

6/10

2
1

390
243

240
145

0,95
0,43

2700
2280

B3541124

1 x 230

6/10

2
1

1020
950

620
450

4,60
4,50

2800
2500

35

3 x 230

6/10

2
1

885
650

480
370

3,02
2,04

2700
2280

B3541100

3 x 400

6/10

2
1

885
650

480
370

1,75
1,18

2700
2050

B3541702

3 x 230

6/10

2
1

1330
940

730
530

4,42
2,85

2700
2280

2
1

1330
940

730
530

2,55
1,65

2760
2260

CODE

MODEL

VOLT.

B3520274
B3520252

B3540552

B3541102

R4CD 50 - 30

R4CD 50 - 60

R2CD 50 - 120

R2CD 50 - 180
3 x 400

B3541700

6/10

Amp.

50

100 200 300 400 500

12

18

3,0
2,5

2,8
2,2

2,6
1,9

2,0
1,0

1,0
0,2

5,6
5,0

5,4
4,5

5,2
3,9

4,2
2,5

2,9
1,0

6,9
5,2

6,7
4,8

6,3
4,1

4,7
2,4

2,2
0,4

11,6 11,2 10,8 9,4


10,1 9,1 8,2 6,4

7,2
4,2

4,5
2,0

1,5

17,0 16,0 14,8 12,0


14,0 12,4 10,6 7,5

9,0
3,8

4,3

0,2

Q
3

m /h

Discharge head
in meters

PN
(bar)

SPEED

PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

24

30

1,0

Counterflanges not included


B1
L4

B2

L5

B3

H2
H3

M
G 1/4
B4

D7

H1

B4

B5

D5
G1/8
D1
D2
D3

L2

L3
L1

D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1 L2

L3 L4

L5 B1 B2 B3 B4 B5

Weight (Kg) Pack


vol.
(m3)
M net gross

R4CD 50 - 30

50 90 110 165 14

4 125 19

76 225 301 280 117 163 120 96 380 193 187 100 200 M12 31

34 0,081

R4CD 50 - 60

50 90 110 165 14

4 125 19

76 260 336 280 120 160 120 120 440 220 220 120 240 M12 43

46 0,081

R2CD 50 - 60

50 90 110 165 14

4 125 19

76 225 301 280 120 160 120 96 440 220 220 100 200 M12 31

34 0,081

R2CD 50 - 120

50 90 110 165 14

4 125 19

76 260 336 280 120 160 120 120 440 220 220 120 240 M12 45

48 0,081

R2CD 50 - 180

50 90 110 165 14

4 125 19

76 261 337 280 120 160 120 120 440 220 220 120 240 M12 48

51 0,081

36

R2CD - R4CD 50
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

With only one head in operation

With only one head in operation

R2CD - R4CD

With only one head in operation

With only one head in operation

37

R2CD - R4CD 65
PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
SPEED

max

3 x 230 6/10

2
1

305
185

210
120

1,52
0,70

1330
1010

B3620250

3 x 400 6/10

2
1

305
185

210
120

0,87
0,40

1330
1010

B3640552

3 x 230 6/10

2
1

540
370

280
175

2,55
1,30

1400
1190

B3640550

3 x 400 6/10

2
1

540
370

280
175

1,47
0,55

1400
1190

B3620502

3 x 230 6/10

2
1

478
328

302
208

1,70
1,02

2780
2270

B3620500

3 x 400 6/10

2
1

478
328

302
208

0,98
0,59

2780
2270

B3641102

3 x 230 6/10

2
1

1330
940

730
530

4,42
2,85

2760
2260

B3641100

3 x 400 6/10

2
1

1330
940

730
530

2,55
1,65

2760
2260

B3641702

3 x 230 6/10

2
1

1970
1510

950
720

6,65
4,50

2810
2420

3 x 400 6/10

2
1

1970
1510

950
720

3,85
2,60

2810
2420

CODE

MODEL

VOLT

B3620252

PN
(bar)

R4CD 65 - 30

R4CD 65 - 60

R2CD 65 - 60

R2CD 65 - 120

R2CD 65 - 180
B3641700

min

L/1'

n
(min-1)

Amp.

100

200 300 400 600 800

12

18

24

36

2,9
2,4

2,8
2,1

2,4
1,6

2,1
1,1

1,5
0,5

0,1

5,5
5,1

5,4
4,1

4,8
3,4

4,2
2,4

3,2
1,6

3,2

6,3
5,1

6,0
4,3

5,3
3,2

4,2
2,1

2,8
0,9

Q
3

m /h

Discharge head
in meters

Motor
power
W

11,8 11,4 10,9 10,1 8,7


9,5 9,0 7,9 6,9 5,7

6,1
2,7

48

1,5

18,0 16,9 15,2 12,7 10,6 2,5


15,5 13,6 11,0 8,8 6,3 0,4

Counterflanges not included

B1
L4

B2

L5

B3

H2
H3

M
G 1/4
B4

D7

H1

B4

B5

D5
G1/8
D1
D2
D3

L2

L3
L1

D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1 L2 L3 L4

L5 B1 B2 B3

Weight (Kg) Pack.


vol.
(m3)
B4 B5 M net gross

R4CD 65 - 30

65 110 130 185 14

145 19

84 226 310 340 136 204 140 96 404 208 196 120 240 M12 40

45 0,096

R4CD 65 - 60

65 110 130 185 14

145 19

84 261 345 340 140 200 140 120 455 231 224 100 200 M12 53

58 0,096

R2CD 65 - 60

65 110 130 185 14

145 19

84 226 310 340 140 200 140 96 455 231 224 120 240 M12 40

45 0,096

R2CD 65 - 120

65 110 130 185 14

145 19

84 261 345 340 140 200 140 120 455 231 224 120 240 M12 54

59 0,096

R2CD 65 - 180

65 110 130 185 14

145 19

84 289 373 340 140 200 140 120 455 231 224 120 240 M12 59

64 0,096

38

R2CD - R4CD 65
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

With only one head in operation

With only one head in operation

R2CD - R4CD

With only one head in operation

With only one head in operation

39

R2CD - R4CD 80
Motor
power
W
max
min

R4CD 80 - 30

33x230
x 230

6
10

2
1

390
273

270
185

1,82
1,00

1405
1200

R4CD 80 - 30

33x400
x 400

6
10

2
1

390
273

270
185

1,05
0,58

1405
1200

R4CD 80 - 60 33x230
x 230

6
10

2
1

975
710

470
290

4,75
2,50

1400
1200

MODEL

B3840252
B3840180
B3840250
B3840190
B3840552
B3840200
B3840550
B3840210
B3841102
B3840220
B3841100
B3840230
B3841702

VOLT

PN
(bar)

2
1

975
710

470
290

2,75
1,45

1400
1200

R2CD 80 - 120

33x230
x 230

6
10

2
1

1970
1510

950
720

6,65
4,50

2810
2420

R2CD 80 - 120

6
33x400
x 400
10

2
1

1970
1510

730
530

3,85
2,60

2810
2420

6
10

2
1

2520
1780

2320
1040

7,60
5,40

2800
2450

B3841700

6
x 400
R2CD 80 - 180 33x400
10

2
1

2520
1780

2320
1040

4,40
3,10

2800
2450

B3840260

100

15

30

45

3,7

3,6

3,2

1,9

0,2

3,1

2,8

2,2

0,7

6,0

5,9

5,7

4,7

3,2

5,4

5,2

4,8

3,2

0,9

11,2 11,0 10,8 9,8

7,8

5,4

4,7

2,2

L/1'

n
(min-1)

6
R4CD 80 - 60 33x400
x 400
10

x 230
R2CD 80 - 180 33x230

B3840240

Amp.

250 500 750 1000 1250

Q
3

m /h

Discharge head
in meters

CODE

SPEED

PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

10,2

9,6

8,8

6,9

60

75

0,8

1,3

17,8 17,5 16,7 13,1 4,6


15,2 14,6 12,8 7,4

Counterflanges not included

B1
L4

B1

B2

L5

B3

B2

B3

H2
H3

G1/8

H1

B4

B5

B4

G 1/4

G1/8
D1
D2
D3
D4

D1
D2
D3
D4

PN 6

L2

L3
L1

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1 D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5

B1

B2 B3

B4 B5

Weight (Kg) Packing


volume
(m3)
net gross

R4CD 80 - 30

80 128 150 190 19

98 269 367 360 145 215 143 120 464 236 228 120 240 M12 50

55

0,096

R4CD 80 - 60

80 128 150 190 19

98 289 387 360 145 215 143 120 464 236 228 100 200 M12 60

65

0,096

R2CD 80 - 120

80 128 150 190 19

98 289 387 360 145 215 143 120 464 236 228 120 240 M12 61

66

0,096

R2CD 80 - 180

80 128 150 190 19

98 289 387 360 145 215 143 120 464 236 228 120 240 M12 61

66

0,096

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1 D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5

B1

B2 B3

B4 B5

Weight (Kg) Packing


volume
(m3)
net gross

R4CD 80 - 30 10

80 128 160 200 19

98 269 367 360 145 215 143 120 464 236 228 120 240 M12 50

55

0,096

R4CD 80 - 60 10

80 128 160 200 19

98 289 387 360 145 215 143 120 464 236 228 100 200 M12 60

65

0,096

R2CD 80 - 120 10

80 128 160 200 19

98 289 387 360 145 215 143 120 464 236 228 120 240 M12 61

66

0,096

R2CD 80 - 180 10

80 128 160 200 19

98 289 387 360 145 215 143 120 464 236 228 120 240 M12 61

66

0,096

40

R2CD - R4CD 80
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

With only one head in operation

With only one head in operation

R2CD - R4CD

With only one head in operation

41

R4CD 100

MODEL

VOLT.

PN
(bar)

Motor
power
W
max
min

6
10

2
1

669
420

B3040252
R4CD 100 - 30 3 x 230
B3040150
B3040250

495
340

Amp.

2,85
1,55

6
10

2
1

669
420

495
340

1,65
0,90

1370
1130

R4CD 100 - 60 3 x 230

6
10

2
1

1235
810

880
595

5,42
2,95

1375
1120

B3040160
B3040552
B3040170

m /h

B3040550
R4CD 100 - 60 3 x 400
B3040180

6
10

2
1

1235
810

880
595

3,12
1,70

250

500 750 1000 1250 1500

15

30

45

60

75

3,7

3,4

3,0

2,3

1,4

0,1

3,0

2,6

2,1

1,2

0,1

6,0

5,7

5,2

4,7

3,8

2,6

4,6

4,2

3,5

2,7

1,6

0,3

1370
1130

3 x 400

R4CD 100 - 30

L/1'

n
(min-1)

90

Discharge head
in meters

CODE

SPEED

PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

1,1

1375
1120

Counterflanges not included

B1
L4

B1

B2

L5

B3

B2

B3

H2
H3

G1/8

H1

B4

B5

B4

G 1/4

G1/8
D1
D2
D3
D4

D1
D2
D3
D4

PN 6

L2

L3
L1

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1 D2 D3 D4

D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5

B1

B2 B3 B4

B5

Weight (Kg) Packing


volume
(m3)
M net gross

R4CD 100 - 30

100 148 170 210 19

108 306 414 450 189 261 187 140 560 286 274 140 240 M16 80

87

0,224

R4CD 100 - 60

100 148 170 210 19

108 327 435 450 189 261 187 140 560 286 274 140 240 M16 82

89

0,224

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1 D2 D3 D4

D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5

B1

B2 B3 B4

B5

Weight (Kg) Packing


volume
(m3)
M net gross

R4CD 100 - 30 10 100 148 180 220 19

108 306 414 450 189 261 187 140 560 286 274 140 240 M16 80

87

0,224

R4CD 100 - 60 10 100 148 180 220 19

108 327 435 450 189 261 187 140 560 286 274 140 240 M16 82

89

0,224

42

R4CD 100
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

R4CD

With only one head in operation

43

R2T - R4T
R2T - R4T CIRCULATING PUMPS

Mechanically sealed circulation pumps are suitable for the circulation of hot and cold
water in heating and air-conditioning systems. The type of design: external motor,
mechanical seal and inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2C - R4C series).

Applications

Usage limitations

- Non-aggressive and non-explosive


clean liquids free of suspended solid
particles and fibres
- Hot water or coolants not containing
mineral oils
- Liquid temperature:
from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature:
40 C
- The pump may be installed with the
driving shaft in all positions between
horizontal and vertical
- Flanged ports:
DN 40-50-65 PN 6/10
DN 80-100
PN 6
DN 80-100
PN 10

Heating and air-conditioning systems


Water supply systems
Booster systems
Agriculture and fruit and vegetable
crops

Motor
- Squirrel cage asynchronous three
phase with enclosed stator,
externally ventilated, 2 pole (R2T)
or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise
(motor end view)

DESIGN FEATURES
Component

44

Material

Pump casing
Impeller
Shaft

EN-GJL 200 ( ex G20 ) cast iron


X5 CrNi 1810 ( Aisi 304 ) stainless steel
X 17 CrNi 16-2 ( Aisi 431 ) stainless steel

Mechanical seal

Graphite primary ring,


tungsten carbide secondary ring

O-Ring

EPDM

R2T - R4T
Performance range

H
[m]
20
16
R2T
50 - 180

12

R2T
80 - 180

R2T
65 - 180

R2T
100 - 120

10
R2T
40 - 120

R2T
50 - 120

R2T
80 - 120

6
R2T
40 - 60

R2T
65 - 120

4
R4T
50 - 60

R4T
80 - 60

R4T
65 - 60

R4T
100 - 60

R4T
40 - 30
2
R4T
65 - 30
R4T
50 - 30

R4T
80 30

R4T
100 - 30

1
3

6 7 8

10

20

30

40 50 60

3
80 100 Q [m /h]

R2T - R4T

45

R2T - R4T 40
PUMP PERFORMANCE
MODEL

PN
(bar)

Motor
power
(Kw)

n -1
(min )

Amp.

R4T 40 - 30

6/10

0,25

1,10

1,90

1380

4,6

B2001015

R2T 40 - 60

6/10

0,37

1,00

1,73

2840

4,1

B2001017

R2T 40 - 120

6/10

0,55

1,45

2,50

2810

5,2

25

50

100 150 200 250

1,5

3,3

3,2

3,1

2,7 2,4

1,7

6,8

6,7

6,5

5,8

4,8

3,4

1,8

12,0 11,8 11,4 10,5 9,2

7,4

5,3

Q
3

m /h

3x400V 3x230V

B2001011

L/1'

la/ln
(%)

Discharge head
in meters

CODE

12

15

D4

D1
D2

D3

D6

Counterflanges not included

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D3

D4 D5 nD5 D6 D7 nD7 H1

D1

D2

R4T 40 - 30

42

80 100 150

14

110 19

67

343 410 250 70

R2T 40 - 60

42

80 100 150

14

110 19

67

R2T 40 - 120

42

80 100 150

14

110 19

67

343 410 250 70

46

H2

H3

L1

B1

B2

B3

B4

B5

101 75

90

96 M12 20

22

0,039

343 410 250 70 101 75

90

96 M12 20

22

0,039

90

96 M12 20

22

0,039

101 75

Weight (Kg) Packing


volume
(m3)
net gross

R2T - R4T 40

R2T - R4T

TABLE OF HYDRAULIC PERFORMANCE

47

R2T - R4T 50
PUMP PERFORMANCE
MODEL

PN
(bar)

Motor
power
(Kw)

n -1
(min )

Amp.

R4T 50 - 30

6/10

0,25

1,10

1,90

1380

4,6

B2001023

R4T 50 - 60

6/10

0,37

1,25

2,15

1390

4,2

B2001027

R2T 50 - 120

6/10

0,75

1,90

3,30

2810

4,5

B2001025

R2T 50 - 180

6/10

1,10

2,60

4,50

2860

5,2

50

100 200 300 400 700

12

18

3,1

3,0

2,8

2,5

1,5

5,9

5,7

5,4

4,5

3,3 1,4

12,0 11,9 11,6 10,8

9,1 7,0

3,9

17,5 16,5 15,7 13,3 10,2 6,0

1,2

Q
3

m /h

3x400V 3x230V

B2001021

L/1'

la/ln
(%)

Discharge head
in meters

CODE

24

30

D4

D1
D2

D3

D6

Counterflanges not included

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model

D4 D5 nD5 D6 D7 nD7 H1 H2

D1

D2 D3

R4T 50 - 30

50

90 110 165 14

125

19

75 337 412 280

70 101 75 102

96 M12 23

25

0,039

R4T 50 - 60

50

90 110 165 14

125

19

75 337 412 280

70 101 101 102 96 M12 24

26

0,039

R2T 50 - 120

50

90 110 165 14

125

19

75 337 412 280

80 115 101 102

96 M12 26

29

0,073

R2T 50 - 180

50

90 110 165 14

125

19

75 337 412 280

80 115 101 102

96 M12 28

31

0,073

48

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R2T - R4T 50

R2T - R4T

TABLE OF HYDRAULIC PERFORMANCE

49

R2T - R4T 65
PUMP PERFORMANCE
MODEL

PN
(bar)

Motor
power
(Kw)

n -1
(min )

Amp.

la/ln
(%)

3x400V 3x230V

B2001031

R4T 65 - 30

6/10

0,25

1,10

1,90

1380

4,6

B2001033

R4T 65 - 60

6/10

0,37

1,25

2,15

1390

4,2

B2001037

R2T 65 - 120

6/10

1,10

2,50

4,30

2840

5,8

B2001035

R2T 65 - 180

6/10

1,50

3,40

5,90

2870

6,0

L/1'

100

200 300 400 500 700

m3/h

12

18

24

3,0

2,9

2,7

2,3

1,8 1,2

5,5

5,4

4,9

4,4

3,6 2,7

11,3 11,0 10,4

9,9

9,0 7,8

Discharge head
in meters

CODE

30

42

4,2

17,4 16,8 15,7 13,8 10,8 6,7

D4

D1
D2

D3

D6

Counterflanges not included

D5
D7

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1

D2

D3 D4 D5 nD5 D6 D7 nD7 H1 H2

H3

L1

B1

B3

B4

B5

75 124

96 M12 26

29

0,073

75 124

96 M12 29

32

0,073

82 382 464 340

80 115 101 124

96 M12 33

36

0,073

82 401 483 340

90 115 101 124

96 M12 36

39

0,073

R4T 65 - 30

65

110 130 185

14

145 19

82 347 429 340

R4T 65 - 60

65

110 130 185

14

145 19

82 347 429 340 80

R2T 65 - 120

65

110 130 185

14

145 19

R2T 65 - 180

65

110 130 185

14

145 19

50

B2

Weight (Kg) Packing


volume
(m3)
net gross

70 101
101

R2T - R4T 65

R2T - R4T

TABLE OF HYDRAULIC PERFORMANCE

51

R2T - R4T 80
PUMP PERFORMANCE
PN
(bar)

MODEL

B2001041

n -1
Amp.
(min )
3x400V 3x230V
max
min

Motor
power
(Kw)

la/ln
(%)

L/1'

200

300 400 500 750 1000

12

18

24

30

3,7

3,3

3,0

2,5

2,0

6,0

5,8

5,6

5,3

4,9 3,3

Q
3

m /h

45

60

6
R4T 80 - 30

0,25

1,10

1,90

1380

4,6

0,75

2,25

3,90

1405

5,1

2,20

4,80

8,30

2870

4,8

2,20

4,80

8,30

2870

4,8

10

B2000100
B2001043

6
R4T 80 - 60

B2000110

Discharge head
in meters

CODE

10

B2001047

6
R2T 80 - 120

11,7 11,4 11,2 10,6 10,3 8,4

5,5

10

B2000120

B2001045
R2T 80 - 180

17,6 17,0 16,4 15,0 13,4 6,4

10

B2000130

D4

D2

D1

D3

Counterflanges not included

D5

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4T 80 - 30

80

128

150

190

19

97

348

445

360

70

101

101

130

96

M12

32

35

0,073

R4T 80 - 60

80

128

150

190

19

97

383

480

360

80

115

101

130

96

M12

36

39

0,073

R2T 80 - 120

80

128

150

190

19

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

R2T 80 - 180

80

128

150

190

19

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight(Kg) Packing
volume
(m3)
net gross

R4T 80 - 30

10

80

128

160

200

19

97

348

445

360

70

101

101

130

96

M12

32

35

0,073

R4T 80 - 60

10

80

128

160

200

19

97

383

480

360

80

115

101

130

96

M12

36

39

0,073

R2T 80 - 120

10

80

128

160

200

19

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

R2T 80 - 180

10

80

128

160

200

19

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

52

R2T - R4T 80

R2T - R4T

TABLE OF HYDRAULIC PERFORMANCE

53

R2T - R4T 100


PUMP PERFORMANCE
CODE

MODEL

PN
(bar)

B2001051

Motor
power
(Kw)

n -1 l / l
Amp.
(min ) a n
(%)
3x400V 3x230V
max
min

L/1'

250

500 750 1000 1250 1400

15

30

45

60

4,0

3,7

3,2

2,4

1,3

6,0

5,9

5,7

5,3

4,6

3,4

13,0 12,7 12,4 11,2

9,4

7,4

Q
3

m /h

75

84

6
R4T 100 - 30

B2000140

0,55

1,70

2,90

1390

4,5

1,10

3,00

5,20

1395

4,0

3,00

6,30

10,90

2870

4,2

B2001053

Discharge head
in meters

10
6
R4T 100 - 60

B2000150

10

B2001057

6
R2T 100 - 120

B2000160

4,5

10

D4

D2

D1

D3

Counterflanges not included

D5

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4T 100 - 30

100

148

170

210

19

107

421

528

450

80

115

101

167

144 M16

49

56

0,249

R4T 100 - 60

100

148

170

210

19

107

457

564

450

90

115

101

167

144 M16

57

64

0,249

R2T 100 - 120

100

148

170

210

19

107

507

614

450

100

130

101

167

144 M16

62

69

0,249

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4T 100 - 30

10

100

148

180

220

19

107

421

528

450

80

115

101

167

144 M16

49

56

0,249

R4T 100 - 60

10

100

148

180

220

19

107

457

564

450

90

115

101

167

144 M16

57

64

0,249

R2T 100 - 120

10

100

148

180

220

19

107

507

614

450

100

130

101

167

144 M16

62

69

0,249

54

R2T - R4T 100

R2T - R4T

TABLE OF HYDRAULIC PERFORMANCE

55

R2TD - R4TD
R2TD - R4TD TWIN HEAD CIRCULATING PUMPS

Mechanically sealed circulation pumps are suitable for the circulation of hot and cold
water in heating and air-conditioning systems. The type of design: external motor,
mechanical seal and inline flanged connections, is the alternative type of design and
completes the wet runner circulating pumps (R2CD - R4CD series).

Applications

Usage limitations

- Non-aggressive and non-explosive


clean liquids free of suspended
solid particles and fibres
- Hot water or coolants not containing
mineral oils
- Liquid temperature:
from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature:
40 C
- The pump may be installed with the
driving shaft in all positions between
horizontal and vertical
- Flanged ports:
DN 40-50-65 PN 6/10
DN 80-100
PN 6
DN 80-100
PN 10

Heating and air-conditioning systems


Water supply systems
Booster systems
Agriculture and fruit and vegetable
crops

Motor
- Squirrel cage asynchronous three
phase with enclosed stator,
externally ventilated, 2 pole (R2TD)
or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise
(motor end view)

DESIGN FEATURES
Component

56

Material

Pump casing
Impeller

EN-GJL 200 ( ex G20 ) cast iron


X5 CrNi 1810 ( AISI 304 ) stainless steel

Shaft

X17 CrNi 16-2 ( AISI 431 ) stainless steel

Mechanical seal

Graphite primary ring,


tungsten carbide secondary ring

O-Ring

EPDM

R2TD - R4TD
Performance range

H
[m]
20
16
R2TD
50 - 180

12

R2TD
80 - 180

R2TD
65 - 180

R2TD
100 - 120

10
R2TD
40 - 120

R2TD
50 - 120

R2TD
80 - 120

6
R2TD
40 - 60

R2TD
65 - 120

4
R4TD
50 - 60

R4TD
80 - 60

R4TD
65 - 60

R4TD
100 - 60

R4TD
40 - 30
2
R4TD
65 - 30
R4TD
50 - 30

R4TD
80 30

R4TD
100 - 30

1
3

6 7 8

10

20

30

40 50 60

3
80 100 Q [m /h]

R2TD - R4TD

57

R2TD - R4TD 40
PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
MODEL

PN
(bar)

Motor
power
(Kw)

n -1 l / l
(min ) a n
(%)

Amp.

L/1'
3

m /h

3x400 V 3x230 V

B2001010

R4TD 40 - 30

6 / 10

2 x 0,25

1,10

1,90

1380

4,6

B2001016

R2TD 40 - 60

6 / 10

2 x 0,37

1,00

1,73

2840

4,1

B2001018

R2TD 40 - 120

6 / 10

2 x 0,55

1,45

2,50

2810

5,2

25

50

100

150

200

1,5

12

3,3

3,1

2,8

2,4

1,8

6,8

6,2

5,8

4,8

3,6

2,0

12,0

11,5 11,2

10,0

8,5

6,2

Discharge head
in meters

CODE

Counterflanges not included

D7
D5

D1
D2
D3
D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1

L2 L3 L4

L5 B1

B2 B3 B4 B5

Weight (Kg) Pack.


vol.
(m3)
M net gross

R4TD 40 - 30 42 80 100 150 14

110 19

68 343 411 250 99 151 97

96 184 101 180 100 200 M12 27

30 0,068

R2TD 40 - 60 42 80 100 150 14

110 19

68 343 411 250 99 151 97

96 184 101 180 100 200 M12 27

30 0,068

R2TD 40 - 120 42 80 100 150 14

110 19

68 343 411 250 99 151 97 96 184 101 180 100 200 M12 29

32 0,073

58

R2TD - R4TD 40
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

R2TD - R4TD

With only one head in operation

With only one head in operation

59

R2TD - R4TD 50
PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
MODEL

PN
(bar)

n -1 l / l
Motor
Amp.
(min ) a n
power
(%)
(Kw) 3x400 V 3x230 V

B2001020

R4TD 50 - 30

6 / 10

2 x 0,25

1,10

1,90

1380

4,6

B2001022

R4TD 50 - 60

6 / 10

2 x 0,37

1,25

2,15

1390

4,2

B2001028

R2TD 50 - 120

6 / 10

2 x 0,75

1,90

3,30

2810

4,5

B2001026

R2TD 50 - 180

6 / 10

2 x 1,10

2,60

4,50

2860

5,2

L/1'

50

100

200

300

400

12

18

24

3,1

2,8

2,7

1,9

0,8

5,9

5,7

5,4

4,2

3,6

1,4

12,0

11,8 11,3

9,9

7,8

5,2

17,5

16,1

13,2

10,0

5,8

Q
3

m /h

Discharge head
in meters

CODE

15,3

Counterflanges not included

D7
D5

D1
D2
D3
D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model
D1 D2 D3

D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1

L2

L3 L4

L5 B1 B2 B3 B4 B5

Weight (Kg) Pack.


vol.
(m3)
M net gross

R4TD 50 - 30 50

90 110 165 14

4 125 19

76 337 413 280 117 163 120 96 380 193 187 100 200 M12 31

34 0,073

R4TD 50 - 60 50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12 43

46 0,073

R2TD 50 - 120 50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12 31

34 0,073

R2TD 50 - 180 50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12 35

38 0,073

60

R2TD - R4TD 50

With only one head in operation

With only one head in operation

With only one head in operation

With only one head in operation

61

R2TD - R4TD

TABLE OF HYDRAULIC PERFORMANCE

R2TD - R4TD 65
PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
MODEL

PN
(bar)

n -1 l / l
Motor
Amp.
(min ) a n
power
(%)
(Kw) 3x400 V 3x230 V

B2001030

R4TD 65 - 30

6 / 10

2 x 0,25

1,10

1,90

1380

4,6

B2001032

R4TD 65 - 60

6 / 10

2 x 0,37

1,25

2,15

1390

4,2

B2001038

R2TD 65 - 120

6 / 10

2 x 1,10

2,50

4,30

2840

5,8

B2001036

R2TD 65 - 180

6 / 10

2 x 1,50

3,40

5,90

2870

6,0

L/1'

100

200

300

400

500

12

18

24

30

3,0

2,8

2,4

1,9

1,3

5,3

5,2

4,7

4,0

2,8

1,6

11,0

10,9

10,4

9,3

8,2

7,0

17,4

16,8

15,7

13,8

10,8

7,2

Q
3

m /h

Discharge head
in meters

CODE

Counterflanges not included

D7
D5

D1
D2
D3
D6
D4

DIMENSIONS AND WEIGHTS


Dimensions mm.

Model

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1

L2 L3

L4

L5 B1 B2 B3 B4 B5

Weight (Kg) Pack.


vol.
(m3)
M net gross

R4TD 65 - 30 65 110 130 185 14

4 145 19

84 347 431 340 136 204 120 96 404 208 196 120 240 M12 45

50

0,073

R4TD 65 - 60 65 110 130 185 14

4 145 19

84 347 431 340 140 200 140 120 455 231 224 100 200 M12 40

45

0,073

R2TD 65 - 120 65 110 130 185 14

4 145 19

84 382 466 340 140 200 140 120 455 231 224 120 240 M12 40

45

0,073

R2TD 65 - 180 65 110 130 185 14

4 145 19

84 401 485 340 140 200 140 120 455 231 224 120 240 M12 46

51

0,073

62

R2TD - R4TD 65
TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

With only one head in operation

With only one head in operation

63

R2TD - R4TD

With only one head in operation

R2TD - R4TD 80
PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
CODE

MODEL

PN
(bar)

B2001040

Motor
power
(Kw)

n -1 l / l
(min ) a n
(%)

Amp.

L/1'

200 300 400 500

750 1000

12

18

24

30

45

3,7

3,2

2,7

2,2

1,5

6,0

5,7

5,2

4,7

4,3

2,5

11,7 11,0 10,4

9,8

9,2

6,8

17,6 17,0 16,4 15,5 14,3

6,4

Q
3

m /h

3x400 V 3x230 V

60

6
R4TD 80 - 30

B2000170

2 x 0,25

1,10

1,90

1380

4,6

2 x 0,75

2,25

3,90

1405

5,1

2 x 2,20

4,80

8,30

2870

4,8

2 x 2,20

4,80

8,30

2870

4,8

10

B2001042

10

B2000180
B2001048

6
R2TD 80 - 120

Discharge head
in meters

6
R4TD 80 - 60

3,5

10

B2000190
B2001046

6
R2TD 80 - 180

B2000200

10

D4

D2

D1

D3
D5

Counterflanges not included

G 1/8

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1

D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5 B1

B2 B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4TD 80 - 30 6

80 128 150 190 19

98 348 446 360 145 215 140 120 464 236 228 120 240 M12

54

59

0,073

80 128 150 190 19

98 375 481 360 145 215 143 120 464 236 228 120 240 M12 50

55

0,073

R2TD 80 - 120 6

80 128 150 190 19

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

60

65

0,224

R2TD 80 - 180 6

80 128 150 190 19

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

66

65

0,224

R4TD 80 - 60

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1

D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5 B1

B2 B3

B4

B5

Weight (Kg) Packing


volume
(m3)
net gross

R4TD 80 - 30 10

80 128 160 200 19

98 348 446 360 145 215 140 120 464 236 228 120 240 M12

54

59

0,073

R4TD 80 - 60 10

80 128 160 200 19

98 375 481 360 145 215 143 120 464 236 228 120 240 M12 50

55

0,073

R2TD 80 - 120 10

80 128 160 200 19

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

60

65

0,224

R2TD 80 - 180 10

80 128 160 200 19

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

66

65

0,224

64

R2TD - R4TD 80

With only one head in operation

With only one head in operation

With only one head in operation

With only one head in operation

65

R2TD - R4TD

TABLE OF HYDRAULIC PERFORMANCE

R2TD - R4TD 100


PUMP PERFORMANCE WITH ONLY ONE HEAD IN OPERATION
CODE

MODEL

PN
(bar)

B2001050

n -1 l / l
Motor
Amp.
(min ) a n
power
(%)
(Kw) 3x400 V 3x230 V

250

500

750

1000

15

30

45

60

3,8

3,3

2,8

2,1

6,0

5,6

5,1

4,3

3,4

13,8

13,2

12,1

10,6

8,6

L/1'
Q
3

m /h

6
R4TD 100 - 30

2 x 0,55

1,70

2,90

1390

4,5

2 x 1,10

3,00

5,20

1395

4,0

2 x 3,00

6,30

10,90

2870

4,2

B2001052

6
R4TD 100 - 60

B2000220

10

B2001058

Discharge head
in meters

10

B2000210

6
R2TD 100 - 120

B2000230

10

D4

D2

D1

D3
D5

Counterflanges not included

G 1/8

PN 6

PN 10

DIMENSIONS AND WEIGHTS PN 6


Model

Dimensions mm.

PN
bar
D1

D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5 B1

B2 B3

B4

B5

Weight (Kg) Packing


volume
(m3)
M net gross

R4TD 100 - 30

100 148 170 210 19

108 421 529 450 189 261 143 140 560 286 274 140 280 M16 61

68

0,224

R4TD 100 - 60

6 100 148 170 210 19

108 457 565 450 189 261 187 140 560 286 274 140 280 M16 80

87

0,224

R2TD 100 - 120

6 100 148 170 210 19

108 504 615 450 189 261 187 140 560 286 274 140 280 M16 82

89

0,224

DIMENSIONS AND WEIGHTS PN 10


Model

Dimensions mm.

PN
bar
D1

D2 D3

D4 D5 nD5 H1 H2 H3

L1

L2

L3

L4

L5 B1

B2 B3

B4

B5

Weight (Kg) Packing


volume
(m3)
M net gross

R4TD 100 - 30

10 100 148 180 220 19

108 421 529 450 189 261 143 140 560 286 274 140 280 M16 61

68

0,224

R4TD 100 - 60

10 100 148 180 220 19

108 457 565 450 189 261 187 140 560 286 274 140 280 M16 80

87

0,224

R2TD 100 - 120

10 100 148 180 220 19

108 504 615 450 189 261 187 140 560 286 274 140 280 M16 82

89

0,224

66

R2TD - R4TD 100


TABLE OF HYDRAULIC PERFORMANCE

With only one head in operation

R2TD - R4TD

With only one head in operation

With only one head in operation

67

A2L - A4L
"IN LINE" ELECTRIC PUMPS

Applications

Construction features

- Heating and air-conditioning systems


- Water lifting from lakes, rivers, well etc.
- Irrigation systems on ground surface
or by sprinkling.
- Water supply and distribution for
isolated houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.

It is a single impeller centrifugal pump


coupled by a spindle to a totally enclosed
asynchronous motor. The motor cooling
is obtained by means of external
ventilation. The shaft seal is of the
mechanical type.
Single construction. Performance data as
given on the guidelist and on the
nameplate refer to continuous duty and
clear water ( specific Weight: 1000 Kg /
m3 ) with a manometric suction head of 2
meters

Installation

Pump working limits

Since suction and delivery are in-line,


pump can be installed in line with the
piping, either horizontally or vertically. Do
not install the pump with motor facing
downwards.
On request the pumps can be supplied
with flanged counterflanges.

Tolerances

Asynchronous three
phase motor

- Pump : ISO 2548 class C annex B


- Motor : According to CEI standards

Max working pressure: 10 bar .


Max liquid temperature: +130 C .
Min. liquid temperature : -10 C
Max environmental temperature : +40C
Max liquid viscosity : 5 E

- Protection : IP 54.
- Standard voltage :
50Hz : V 220 / 400 ( +- 10% )
- Insulation : Class F.
- A2L model: 2 poles
- A4L model: 4 poles

DESIGN FEATURES
Component

68

Material

Mechanical seal
Pump casing

Silicum carbide / Silicum carbide EPDM O-Ring


EN-GJL 200 ( ex G20 ) cast iron

Impeller
Shaft

EN-GJL 200 ( ex G20 ) cast iron


AISI 420 stainless steel

Shield, lantern, cover

EN-GJL 200 ( ex G20 ) cast iron

A2L - A4L
Performance range
A2L

2 POLES

SINGLE VERSION

H
[m]

100-250

50
40-200
65-200

40

80-200
100-200

50-200

30
40-160
50-160

25

80-160

65-160

100-160

20
40-125

15

50-125

65-125

10
8
6
5
4
1,2

A4L

12

24

60

3
180 Q [m /h]

120

4 POLES

SINGLE VERSION

H
[m]
125-250

20
100-250

15

150-250

80-200
40-200

10

65-200
100-200

8
80-160

40-160

50-200
65-160

100-160

5
50-160

2
0,6

1,2

12

24

60

120

69

180

240 300 Q [m3/h]

A2L - A4L

A2L - A4L 40
PUMP PERFORMANCE
CODE

MODEL

L/1' 50
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 3

Motor
power
(Kw)

75

100 125 150 175 200 225 250 300 350 400

4,5

7,5

10,5 12 13,5 15

N8020380

A4L 40 - 160 X

0,37

N8020390

A4L 40 - 200 Y

0,75

N8020400

A4L 40 - 200 X

0,9

N8020000

A2L 40 - 125 C

0,75

1,9

3,3

2 poles

N8020010

A2L 40 - 125 B

1,0

2,4

4,2

2 poles

N8020020

A2L 40 - 125 A

1,5

3,6

6,2

2 poles

N8020030

A2L 40 - 160 C

2,0

4,4

7,7

2 poles

N8020040

A2L 40 - 160 B

3,0

6,4

11

2 poles

31

N8020050

A2L 40 - 160 A

3,0

6,4

11

2 poles

38 37,5 37

36

35

N8020060

A2L 40 - 200 C

4,0

8,8

15,2

2 poles

47 46,5 46

45

N8020070

A2L 40 - 200 B

5,5

11,3

2 poles

N8020080

A2L 40 - 200 A

6,3

12,8

2 poles

4 poles

9,4 9,2

3,5

4 poles

13 12,8 12,4 11,9 11,3 10,6 9,8

2,4

4,2

4 poles

8,9

8,3 7,7

6,9

6
8

16,5 15,5 14,5 13,5 12,3 11

9,5

20,5 20

19

21

24

5,8 4,7

14,5 14,3 13,8 13,3 12,7 11,8 10,9 10


Discharge head
in meters

1,15

18

18

17

16

15 11,5 7,5

24,5 24 23,5 23

22

21

20 16,5 13

28,5 28 27,5 26,5 25,5 24

23

20

33,5 33 32,5 32

30

29

26 22,5

34

33

30 26,5

44

43

42 39,5 37,5 35

55 54,5 54 53,5

53

52

51

48

62 61,5 61

59

58

57

54 52,5 49

60

15

45

42

Counterflanges not included

E
B

DN : Flanges

DN

n d holes e

DIMENSIONS AND WEIGHTS


Dimensions mm.

Flanges mm.

Weight
(Kg)

Model

Motor

DNa
DNm
a

A4L 40 - 160 X

71

40 PN10

88

110

150

18

425

100

325

215

103

107

320

170

150

23

A4L 40 - 200 X

80

40 PN10

88

110

150

18

445

100

345

245

127

118

380

200

180

31

A4L 40 - 200 Y

80

40 PN10

88

110

150

18

445

100

345

245

127

118

380

200

180

30

A2L 40 - 125 A

80

40 PN10

88

110

150

18

445

100

345

211

93

118

300

160

140

26

A2L 40 - 125 B

80

40 PN10

88

110

150

18

445

100

345

211

93

118

300

160

140

25

A2L 40 - 125 C

71

40 PN10

88

110

150

18

425

100

325

200

93

107

300

160

140

24

A2L 40 - 160 A

90

40 PN10

88

110

150

18

485

100

385

257

108

149

320

170

150

37

A2L 40 - 160 B

90

40 PN10

88

110

150

18

485

100

385

257

108

149

320

170

150

35

A2L 40 - 160 C

80

40 PN10

88

110

150

18

445

100

345

226

108

118

320

170

150

30

A2L 40 - 200 A

112

40 PN10

88

110

150

18

535

100

435

286

127

159

380

200

180

56

A2L 40 - 200 B

112

40 PN10

88

110

150

18

535

100

435

286

127

159

380

200

180

55

A2L 40 - 200 C

110

40 PN10

88

110

150

18

525

100

425

286

127

159

380

200

180

50

70

A2L - A4L 50
PUMP PERFORMANCE
L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 6 7,5 9 10,5 12 13,5 15 18 21 24 27 30 36

CODE

MODEL

Motor
power
(Kw)

N8020410

A4L 50 - 160 X

0,5

N8020420

A4L 50 - 200 Y

1,1

2,6

4,5

4 poles

12,7 12,5 12,1 11,7 11,2 10,7 10,1 8,5

N8020430

A4L 50 - 200 X

1,1

2,6

4,5

4 poles

14,2 14 13,8 13,4 13 12,5 12

N8020090

A2L 50 - 125 C

1,5

3,6

6,2

2 poles

N8020100

A2L 50 - 125 B

2,0

4,4

7,7

2 poles

N8020110

A2L 50 - 125 A

3,0

8,8

15,2

2 poles

N8020120

A2L 50 - 160 B

3,0

6,4

11

2 poles

N8020130

A2L 50 - 160 A

4,0

8,8

15,2

2 poles

N8020140

A2L 50 - 200 C

5,5

11,3

2 poles

46

44

43 41,5 39

N8020150

A2L 50 - 200 B

6,3

12,8

2 poles

51

50

49 47,5 45 42,5 37

N8020160

A2L 50 - 200 A

7,5

17,3

2 poles

4 poles

2,8

8,8 8,6 8,3 8,0 7,7 7,3 6,9 5,9 4,5


7
8,3

10

15,5 15 14,1 13 11,8 10,5 7

Discharge head
in meters

1,6

19 18,5 17,5 16,5 15,5 14,5 10,5


24,5 24 23,5 23
30

29

22 20,5 17

28 26,5 25

23

18

36,5 35,5 34,5 33,5 32,5 31

27

56,5 55,5 54,5 53

51

37
49

31
44

Counterflanges not included

E
B

DN : Flanges

DN

n d holes e

DIMENSIONS AND WEIGHTS


Motor

Dimensions mm.

Flanges mm.

DNa
DNm

Weight
(Kg)

A4L 50 - 160 X

71

50 PN10

102

125

165

18

435

110

325

220

113

107

340

180

160

25

A4L 50 - 200 X

90

50 PN10

102

125

165

18

495

110

385

280

131

149

400

220

180

36

A4L 50 - 200 Y

90

50 PN10

102

125

165

18

495

110

385

280

131

149

400

220

180

36

A2L 50 - 125 A

90

50 PN10

102

125

165

18

495

110

385

252

103

149

320

180

140

32

A2L 50 - 125 B

80

50 PN10

102

125

165

18

455

110

345

221

103

118

320

180

140

28

A2L 50 - 125 C

80

50 PN10

102

125

165

18

455

110

345

221

103

118

320

180

140

27

A2L 50 - 160 A

100

50 PN10

102

125

165

18

535

110

425

272

113

159

340

180

160

42

A2L 50 - 160 B

90

50 PN10

102

125

165

18

495

110

385

262

113

149

340

180

160

32

A2L 50 - 200 A

132

50 PN10

102

125

165

18

650

110

540

315

131

184

400

220

180

64

A2L 50 - 200 B

112

50 PN10

102

125

165

18

545

110

435

290

131

159

400

220

180

57

A2L 50 - 200 C

112

50 PN10

102

125

165

18

545

110

435

290

131

159

400

220

180

56

71

A2L - A4L

Model

A2L - A4L 65
PUMP PERFORMANCE
L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 12 13,5 15 18 21 24 27 30 36 42 48 54 60

CODE

MODEL

Motor
power
(Kw)

N8020440

A4L 65 - 160 Y

0,75

N8020450

A4L 65 - 160 X

0,9

2,4

4,2

4 poles

9,0 8,9 8,8 8,6 8,4 8,1 7,7 7,2 5,5

N8020460

A4L 65 - 200 Y

1,1

2,6

4,5

4 poles

12,4 12,2 12 11,5 10,8 10

N8020070

A4L 65 - 200 X

1,5

3,5

6,1

4 poles

14,3 14,2 14,1 13,7 13 12,3 11,3 10,2 7,8 5,0

N8020180

A2L 65 - 125 C

2,0

4,4

7,7

2 poles

N8020170

A2L 65 - 125 B

3,0

6,4

11

2 poles

N8020190

A2L 65 - 125 A

4,0

8,8

15,2

2 poles

N8020200

A2L 65 - 160 B

5,5

11,3

2 poles

N8020210

A2L 65 - 160 A

7,5

17,3

2 poles

37 36,5 36

35

N8020220

A2L 65 - 200 B

10

22,5

2 poles

51 50,5 50

48 45,5 42 39,5 37

N8020230

A2L 65 - 200 A

12,5

27

2 poles

58 57,5 57

55

4 poles

3,5

8,2

Discharge head
in meters

7,9 7,7 7,4 7,0 6,6 6,0 4,0

9,0 8,0 5,8

17 16,5 16

15

11

21 20,5 20

19 17,5 16

14

12

23 21,5 20

18

25,5 25,3 25

24

13

32,5 32 31,5 30,5 29,5 28

26 23,5

34 32,5 31

53

29

50 46,5 42,5

Counterflanges not included

E
B

DN : Flanges

DN

n d holes e

DIMENSIONS AND WEIGHTS


Model

Motor

Dimensions mm.

Flanges mm.

DNa
DNm

Weight
(Kg)

A4L 65 - 160 X

80

65 PN10

122

145

185

18

485

140

345

240

122

118

400

220

180

33

A4L 65 - 160 Y

80

65 PN10

122

145

185

18

485

140

345

240

122

118

400

220

180

32

A4L 65 - 200 X

90

65 PN10

122

145

185

18

525

140

385

285

136

149

440

240

200

40

A4L 65 - 200 Y

90

65 PN10

122

145

185

18

525

140

385

285

136

149

440

240

200

38

A2L 65 - 125 A

100

65 PN10

122

145

185

18

565

140

425

267

108

159

360

205

155

43

A2L 65 - 125 B

90

65 PN10

122

145

185

18

525

140

385

257

108

149

360

205

155

39

A2L 65 - 125 C

80

65 PN10

122

145

185

18

485

140

345

226

108

118

360

205

155

32

A2L 65 - 160 A

132

65 PN10

122

145

185

18

680

140

540

306

122

184

400

220

180

61

A2L 65 - 160 B

112

65 PN10

122

145

185

18

575

140

435

281

122

159

400

220

180

54

A2L 65 - 200 A

132

65 PN10

122

145

185

18

680

140

540

320

136

184

440

240

200

77

A2L 65 - 200 B

132

65 PN10

122

145

185

18

680

140

540

320

136

184

440

240

200

70

72

A2L - A4L 80
PUMP PERFORMANCE
CODE

L/1' 300 350 400 450 500 600 700 800 900 1000 1100 1200 1250 1500 1750 2000 2250
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 18 21 24 27 30 36 42 48 54 60 66 72 75 90 105 120 135

Motor
power
(Kw)

MODEL

N8020480 A4L 80 - 160 Y

1,1

2,6

4,5

4 poles

8,6 8,5 8,4 8,3 8,2 8,0 7,5 6,8 6,0 5,0

N8020490 A4L 80 - 160 X

1,5

3,5

6,1

4 poles

10,2 10,1 10 9,9 9,8 9,4 9,0 8,5 7,7 6,5

N8020500 A4L 80 - 200 Y

2,2

5,1

8,9

4 poles

N8020510 A4L 80 - 200 X

3,0

6,9

12

4 poles

N8020240 A2L 80 - 160 C

10

22,5

2 poles

N8020250 A2L 80 - 160 B

Discharge head
in meters

12,5 12,4 12,3 12,1 11,7 11,1 10,5 9,6 8,5


15,2 15 14,6 14,3 13,6 12,8 12 11
30,5 30 29,5 29 28,2 27,3 26,5 24 20,5 16

12,5

27

2 poles

N8020260 A2L 80 - 160 A

15

32

2 poles

N8020270 A2L 80 - 200 D

15

32

2 poles

44 43,5 43 42,6 42 41,5 39 35,5 31,5

N8020280 A2L 80 - 200 C

18,5

38

2 poles

51 50 49,5 49 48,5 48,3 46,5 43,5 39,5 35

N8020290 A2L 80 - 200 B

22

44,5

2 poles

57 56,5 56 55,6 55,4 55 53,5 51 48 42,5

36,5 36 35,5 34,5 34 33,2 33 30

27 23

19

41 40,5 40 39,5 38,7 38 37,5 35,5 33 29

24

Counterflanges not included

E
B

DN : Flanges

DN

n d holes e

DIMENSIONS AND WEIGHTS


Motor

Dimensions mm.

Flanges mm.

DNa
DNm

Weight
(Kg)

A4L 80 - 160 X

90

80 PN10

138

160

200

18

545

140

325

280

131

149

440

240

200

40

A4L 80 - 160 Y

90

80 PN10

138

160

200

18

545

140

325

280

131

149

440

240

200

38

A4L 80 - 200 X

100

80 PN10

138

160

200

18

585

140

345

305

146

159

500

275

225

57

A4L 80 - 200 Y

100

80 PN10

138

160

200

18

585

140

345

305

146

159

500

275

225

51

A2L 80 - 160 A

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

85

A2L 80 - 160 B

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

79

A2L 80 - 160 C

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

72

A2L 80 - 200 B

180

80 PN10

138

160

200

18

860

160

700

375

146

229

500

275

225

142

A2L 80 - 200 C

160

80 PN10

138

160

200

18

860

160

700

375

146

229

500

275

225

124

A2L 80 - 200 D

132

80 PN10

138

160

200

18

700

160

540

330

146

184

500

275

225

91

73

A2L - A4L

Model

A2L - A4L 100


PUMP PERFORMANCE
CODE

MODEL

Motor
power

n -1 L/1' 600 700 800 900 1000 1100 1200 1250 1300 1500 1750 2000 2250 2500 2750 3000 3500
Amp.
(min ) Q
3
3x400V 3x230V
m /h 36 42 48 54 60 66 72 75 78 90 105 120 135 150 165 180 210
(Kw)

N8020520 A4L 100 - 160 Y 1,5

3,5

6,1 4 poles

N8020530 A4L 100 - 160 X 2,2

5,1

8,9 4 poles

9,7 9,5 9,3 9,0 8,8 8,5 8,2

N8020540 A4L 100 - 200 Y 3,0

6,9

12

4 poles

12 11,7 11,5 11,3 11 10,5 10

N8020550 A4L 100 - 200 X 4,0

9,2

16

4 poles

14,5 14,2 14 13,8 13,5 13,1 12,7 12,4 12,2 11 9,0 6,5

N8020560 A4L 100 - 250 Y 5,5

12

4 poles

19 18,5 18 17,5 17,4 17

N8020570 A4L 100 - 250 X 7,5

16

4 poles

Discharge head
in meters

7,7 7,5 7,3 7,0 6,7 6,4 6,1 5,7 5,8 5,0
8

7,9 7,1 6,0

9,8 9,5 8,5 7,0

16

14

12

22 21,9 21,7 21,5 21,1 21,9 20

19

17

21 19,5 18 16,5 15

N8020300 A2L 100 - 160 D 10

22,5

2 poles

N8020310 A2L 100 - 160 C 12,5

27

2 poles

N8020320 A2L 100 - 160 B 15

32

2 poles

34 33,7 33,5 33,3 33,2 32,5 31,8 31

29 27,5 26 24,5

N8020330 A2L 100 - 200 D 18,5

38

2 poles

42 41,5 41,2 41 40,8 40 38,5 37

35

33 30,5 38

N8020340 A2L 100 - 200 C 22

44,5

2 poles

47 46,7 46,5 46,5 46,2 45,5 44,5 43

41

39

N8020350 A2L 100 - 200 B 30

58

2 poles

N8020360 A2L 100 - 200 A 37

71

2 poles

55 54,5 54,3 54 54 53 52
57 56,9 56,8 56,8 56,6 56,5 56

N8020370 A2L 100 - 250 D 37

71

2 poles

24 23,6 23,2 23 22,8 22

26 24,5 23 21,5 20 18,5

28,5 28,3 28 27,8 27,7 27

68 67,5 67

66

37

34

51
55

49 47 45
54 52,5 51

43
48

37
42

65

63

61

55

47

58

Counterflanges not included

F
D

DN
a
b
c

n d holes e
DN : Flanges

DIMENSIONS AND WEIGHTS


Model

Motor

Dimensions mm.

Flanges mm.

DNa
DNm

Weight
(Kg)

A4L 100 - 160 X

100 100 PN10

158

180

220

18

615

190

425

295

136

159

525

300

225

50

A4L 100 - 160 Y

90

100 PN10

158

180

220

18

575

190

385

285

136

149

525

300

225

45

A4L 100 - 200 X

112 100 PN10

158

180

220

18

625

190

435

315

156

159

550

300

250

73

A4L 100 - 200 Y

100 100 PN10

158

180

220

18

615

190

425

315

156

159

550

300

250

66

A4L 100 - 250 X

132 100 PN10

158

180

220

18

730

190

540

360

176

184

600

320

280

106

A4L 100 - 250 Y

132 100 PN10

158

180

220

18

730

190

540

360

176

184

600

320

280

96

A2L 100 - 160 B

132 100 PN10 158

180

220

18

730

190

540

320

136

184

525

300

225

91

A2L 100 - 160 C

132 100 PN10

158

180

220

18

730

190

540

320

136

184

525

300

225

84

A2L 100 - 160 D

132 100 PN10

158

180

220

18

730

190

540

320

136

184

525

300

225

76

A2L 100 - 200 A

200 100 PN10

158

180

220

18

995

190

805

413

156

257

550

300

250

213

A2L 100 - 200 B

200 100 PN10

158

180

220

18

995

190

805

413

156

257

550

300

250

195

A2L 100 - 200 C

180 100 PN10

158

180

220

18

890

190

710

386

156

230

550

300

250

153

A2L 100 - 200 D

160 100 PN10

158

180

220

18

890

190

710

386

156

230

550

300

250

135

A2L 100 - 250 D

200 100 PN10

158

180

220

18

995

190

805

433

176

257

600

320

280

220

74

A2L - A4L 125


PUMP PERFORMANCE
L/1' 1000 1100 1200 1500 1750 2000 2250 2500 2750 3000 3500
Q
n
-1
m3/h 60
(min )

MODEL

N8020960

A4L 125 - 250 Y

10

7,5

380/415

17,3

4 poles

N8020970

A4L 125 - 250 X

12,5

9,2

380/415

19

4 poles

VOLTAGE Amp.

Discharge
head
in meters

Motor
power
HP KW

CODE

66

72

90

105 120 135 150 165 180 210

19,5 19,3 19,1 18,9 18,5 17,5 16,5 15,2 14

12

22 21,9 21,8 21,7 21,5 20,5 19,5 18,5 17

15

13

Counterflanges not included

F
D

DN
a
b
c

n d holes e

DIMENSIONS AND WEIGHTS


Model

Motor

Flanges mm.

DNa
DNm
a

Dimensions mm.

Weight
(Kg)

A4L 125 - 250X

132

125 PN16 188

210

250

18

745

195

550

415

195

220

620

340

280

28

120

A4L 125 - 250Y

132

125 PN16 188

210

250

18

745

195

550

415

195

220

620

340

280

28

120

75

A2L - A4L

DN : Flanges

A2L - A4L 150


PUMP PERFORMANCE
MODEL

Motor
power
HP KW

L/1' 1750 2000 2250 2500 2750 3000 3500 4000 4500 5000

Amp.

VOLTAGE

n Q
3
-1
m /h 105
(min )

N8020980

A4L 150 - 250 Z

15

11

380/415

N8020990

A4L 150 - 250 Y

20

15

380/415

32

4 poles

N8021000

A4L 150 - 250 X

20

15

380/415

32

4 poles

22,5 4 poles

Discharge
head
in meters

CODE

120

135

150

165

180 210

240

17,3 16,6 16,2 15,7 14,7 14,2 12,4


20,2 19,8 19,3

19

18,4

18

270

300

10

16,5 14,8 12,6

20,8 20,2 19,7 19,1 18,6

17

15,2 13,2

11

Counterflanges not included

F
D

DN
a
b
c

n d holes e
DN : Flanges

DIMENSIONS AND WEIGHTS


Model

Motor

Dimensions mm.

Flanges mm.

DNa
DNm
a

Weight
(Kg)

A4L 150 - 250Z

132

150 PN16 212

240

285

22

775

220

555

460

210

250

700

370

330

30

160

A4L 150 - 250Y

132

150 PN16 212

240

285

22

975

220

755

510

210

300

700

370

330

30

195

A4L 150 - 250X

132

150 PN16 212

240

285

22

975

220

755

510

210

300

700

370

330

30

195

76

A2L - A4L
Section view

15

16

16

10

14

13

14

11

16

15

12

14

16

10

13

14

Pump casing

Drain plug

Gland cover

10

Vent plug

Lantern - Cover cap

11

Spring washer

Impeller

12

Hexagonal nut

Baffle

13

Tab

Impeller nut

14

Washer

Mechanical seal

15

Motor

Gasket

16

Screw

A2L - A4L

77

A2LD - A4LD
IN LINE TWIN HEAD CIRCULATING PUMPS

Applications

Design features

- Heating and air-conditioning systems


- Water lifting from lakes , rivers, wells,
etc.
- Irrigation systems on ground surface
or by sprinkling.
- Water supply and distribution for isolated
houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.

It is a single impeller centrifugal pump


coupled by a spindle to a totally enclosed
asynchronous motor. The motor cooling
is obtained by means of external
ventilation. The shaft seal is of the
mechanical type.
Twin construction. Performance data as
given on the guidelist and on the
nameplate refer to continuous duty and
clear water ( specific Weight: 1000 Kg /
m3 ) with a manometric suction head
of 2 meters.

Installation

Pump working limits

Since suction and delivery are in-line,


pump can be installed in line with the
piping, either horizontally or vertically. Do
not install the pump with motor facing
downwards.
On request the pumps can be supplied
with flanged counterflanges.

Tolerances

Asynchronous three
phase motor

- Pump: ISO 2548 class C annex B.


- Motor: according to CEI standards.

Max working pressure: 10 bar .


Max liquid temperature: +130 C .
Min. liquid temperature : -10 C
Max environmental temperature : +40C
Max liquid viscosity : 5 E.

- Protection: IP 54
- Standard voltages:
50 Hz: V. 220 - 400 ( +-10 % )
- Insulation: Class F
- A2LD model: 2 poles
A4LD model: 4 poles

DESIGN FEATURES
Component

78

Material

Mechanical seal
Pump casing

Silicum carbide / Silicum carbide EPDM O-Ring


EN-GJL 200 ( ex G20 ) cast iron

Impeller
Shaft

EN-GJL 200 ( ex G20 ) cast iron


AISI 420 stainless steel

Shield, lantern, cover

EN-GJL 200 ( ex G20 ) cast iron

A2LD - A4LD
Performance range
A2LD

2 POLES

TWIN VERSION

H
[m]
50
40
30
50-160

65-160

80-160

25
20

100-200

50-125
40-125

15

10
8
6
5
4
3

A4LD

12

24

60

180 240 Q [m3/h]

120

4 POLES

TWIN VERSION

H
[m]
20
15
10
8
6
5
4

100-200
50-160

80-160
65-160

40-125

50-125

1
0,8
0,6
0,5
0,6

1,2

12

24

60

79

120

180 Q [m3/h]

A2LD - A4LD

A2LD - A4LD 40
PUMP PERFORMANCE
MODEL

N8020800

A4LD 40 - 125 Y

N8020810
N8020580

L/1' 40
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 2,4

Motor
power
(Kw)
0,25

0,85

1,46

4 poles

A4LD 40 - 125 X

0,25

0,85

1,46

4 poles

A2LD 40 - 125 C

0,75

1,9

3,3

2 poles

N8020590

A2LD 40 - 125 B

1,0

2,4

4,4

2 poles

N8020600

A2LD 40 - 125 A

1,5

3,6

6,2

2 poles

Discharge head
in meters

CODE

50

75

4,5

4,6 4,5

4,1

6,2

6,0

100 125 150 175 200 225 250 300 350


6

7,5

3,6 3,0

2,2

5,8 5,2

4,5

10,5 12 13,5 15

9,5

20,5 20

19

21

3,9 3,0

16,5 15,5 14,5 13,5 12,3 11

24,5 24 23,5

18

18

17

16

15 11,5 7,5

23

22

21

20 16,5 13

Counterflanges not included

DN

n d holes e
DN : Flanges

DIMENSIONS AND WEIGHTS


Model

Motor

Flanges mm.

DNa
DNm

Dimensions mm.

Weight
(Kg)

A4LD 40 - 125 X

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

41

A4LD 40 - 125 Y

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

41

A2LD 40 - 125 A

80

40 PN10

88

110

150

18

445

100

345

397

200

197

340

130

210

100

54

A2LD 40 - 125 B

80

40 PN10

88

110

150

18

445

100

345

397

200

197

340

130

210

100

52

A2LD 40 - 125 C

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

50

80

A2LD - A4LD 50
PUMP PERFORMANCE
L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 6 7,5 9 10,5 12 13,5 15 18 21 24 27 30 36

CODE

MODEL

Motor
power
(Kw)

N8020820

A4LD 50 - 125 X

0,37

N8020830

A4LD 50 - 160 X

0,5

1,6

N8020610

A2LD 50 - 125 C

1,5

3,6

N8020620

A2LD 50 - 125 B

2,0

4,4

7,7

2 poles

N8020630

A2LD 50 - 125 A

3,0

6,4

11

2 poles

N8020640

A2LD 50 - 160 B

3,0

6,4

11

2 poles

N8020650

A2LD 50 - 160 A

4,0

8,8

15,2

2 poles

4 poles

6,3 6,2 6,1 6,0 5,8 5,5 5,2 4,6 3,0

2,8

4 poles

8,8 8,6 8,3 8,0 7,7 7,3 6,9 5,9 4,5

6,2

2 poles

Discharge head
in meters

1,15

15,5 15 14,1 13 11,8 10,5 7


19 18,5 17,5 16,5 15,5 14,5 10,5
24,5 24 23,5 23
30

29

22 20,5 17

28 26,5 25

23

18

36,5 35,5 34,5 33,5 32,5 31

27

Counterflanges not included

DN

n d holes e
DN : Flanges

Model

Motor

Dimensions mm.

Flanges mm.

DNa
DNm
a

Weight
(Kg)

A4LD 50 - 125 X

71

50 PN10 102

125

165

18

435

110

325

427

217

210

365

145

220

105

46

A4LD 50 - 160 X

71

50 PN10 102

125

165

18

435

110

325

480

245

235

410

170

240

120

52

A2LD 50 - 125 A

90

50 PN10 102

125

165

18

495

110

385

427

217

210

365

145

220

105

66

A2LD 50 - 125 B

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

58

A2LD 50 - 125 C

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

56

A2LD 50 - 160 A

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

56

A2LD 50 - 160 B

100

50 PN10 102

125

165

18

535

110

425

480

245

235

410

170

240

120

86

81

A2LD - A4LD

DIMENSIONS AND WEIGHTS

A2LD - A4LD 65
PUMP PERFORMANCE
L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
n -1
Amp.
(min ) Q
3
3x400V 3x230V
m /h 12 13,5 15 18 21 24 27 30 36 42 48 54 60

CODE

MODEL

Motor
power
(Kw)

N8020840

A4LD 65 - 160 Z

0,55

N8020850

A4LD 65 - 160 Y

0,75

3,5

4 poles

N8020860

A4LD 65 - 160 X

0,9

2,4

4,2

4 poles

N8020660

A2LD 65 - 160 D

6,4

11

2 poles

N8020670

A2LD 65 - 160 C

8,8

15,2

2 poles

N8020680

A2LD 65 - 160 B

5,5

11,3

2 poles

N8020700

A2LD 65 - 160 A

7,5

17,3

2 poles

2,7

6,7 6,6 6,4 6,1 5,7 5,1 4,3 3,3

4 poles

8,2 8,0 7,9 7,7 7,4 7,0 6,6 6,0 4,0

Discharge head
in meters

1,6

9,0 8,9 8,8 8,6 8,4 8,1 7,7 7,2 5,5


23 22,5 22 21,5 19,8 17,5 15
26,5 26 25,5 24,3 22,6 20,2 18
32,5 32 31,5 30,5 29,5 28
35

37 36,5 36

26 23,5

34 32,5 31

29

Counterflanges not included

DN

n d holes e
DN : Flanges

DIMENSIONS AND WEIGHTS


Model

Motor

Flanges mm.

DNa
DNm
a

Dimensions mm.

Weight
(Kg)

A4LD 65 - 160 X

80

65 PN10 122

145

185

18

475

130

345

543

275

268

450

180

270

140

67

A4LD 65 - 160 Y

80

65 PN10 122

145

185

18

475

130

345

543

275

268

450

180

270

140

65

A4LD 65 - 160 Z

80

65 PN10 122

145

185

18

475

130

345

543

275

268

450

180

270

140

65

A2LD 65 - 160 A

90

65 PN10 122

145

185

18

495

110

385

480

245

235

410

170

240

120

67

A2LD 65 - 160 B

132

65 PN10 122

145

185

18

670

130

540

543

275

268

450

180

270

140

125

A2LD 65 - 160 C

100

65 PN10 122

145

185

18

565

130

435

543

275

268

450

180

270

140

101

A2LD 65 - 160 D

90

65 PN10 122

145

185

18

485

130

345

543

275

268

450

180

270

140

81

82

A2LD - A4LD 80
PUMP PERFORMANCE
CODE

L/1' 300 350 400 450 500 600 700 800 900 1000 1250 1500 1750 2000 2250
n -1
Motor
Amp.
power 3x400V 3x230V (min ) Q 3
m /h 18 21 24 27 30 36 42 48 54 60 75
90 105 120 135
(Kw)

MODEL

N8020870 A4LD 80 - 160 W

2,25

3,9

4 poles

6,3 6,2 6,1

N8020880 A4LD 80 - 160 Z

0,9

2,7

4,7

4 poles

7,3 7,2 7,1

6,3

5,6 4,8 3,9

N8020890 A4LD 80 - 160 Y

1,1

2,6

4,5

4 poles

8,6 8,5 8,4

8,3 8,2 8,0

7,5 6,8 6,0

5,0

N8020900 A4LD 80 - 160 X

1,5

3,5

6,1

4 poles

10,2 10,1 10

9,9 9,8 9,4

9,0 8,5

6,5

N8020690 A2LD 80 - 160 D

7,5

17,3

2 poles

N8020710 A2LD 80 - 160 C

10

22,5

2 poles

N8020720 A2LD 80 - 160 B

12,5

27

2 poles

36,5 36 35,5 34,5 33

N8020730 A2LD 80 - 160 A

15

32

2 poles

41 40,5 40 39,5 38

Discharge head
in meters

0,75

5,9 5,6

4,9

6,8

4,1 3,2

7,7

25 24,9 24,1 23,4 20,5


30,5 30 29,5 29 26,5

17 12,7
24 20,5 16
27

23

19

35,5 33

29

24

30

Counterflanges not included

DN

n d holes e
DN : Flanges

DIMENSIONS AND WEIGHTS


Motor

Flanges mm.

DNa
DNm
a

Dimensions mm.

Weight
(Kg)

A4LD 80 - 160 X

90

80 PN10 138

160

200

18

535

150

385

550

280

270

510

205

305

135

83

A4LD 80 - 160 Y

90

80 PN10 138

160

200

18

535

150

385

550

280

270

510

205

305

135

79

A4LD 80 - 160 Z

80

80 PN10 138

160

200

18

485

150

335

550

280

270

510

205

305

135

74

A4LD 80 - 160 W

80

80 PN10 138

160

200

18

485

150

335

550

280

270

510

205

305

135

72

A2LD 80 - 160 A

112

80 PN10 138

160

200

18

565

130

435

543

275

268

450

180

270

140

110

A2LD 80 - 160 B

132

80 PN10 138

160

200

18

690

150

540

550

280

270

510

205

305

135

175

A2LD 80 - 160 C

132

80 PN10 138

160

200

18

690

150

540

550

280

270

510

205

305

135

162

A2LD 80 - 160 D

132

80 PN10 138

160

200

18

690

150

540

550

280

270

510

205

305

135

141

83

A2LD - A4LD

Model

A2LD - A4LD 100


PUMP PERFORMANCE
CODE

MODEL

Motor
power

n -1 L/1' 500 600 700 800 900 1000 1100 1200 1300 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000
Amp.
(min ) Q
3x400V 3x230V
m3/h 30 36 42 48 54 60 66 72 78 90 105 120 135 150 165 180 195 210 225 240
(Kw)

N8020910 A4LD 100 - 200W 1,5

3,8

6,6 4 poles

N8020920 A4LD 100 - 200Z 2,2

5,1

8,9 4 poles

10 9,7 9,3 8,9 8,5 8,0 7,5 7,0 6,0

N8020930 A4LD 100 - 200Y 3,0

6,9

12 4 poles

12 11,7 11,5 11,3 11 10,5 10 9,5 8,5 7,0

N8020940 A4LD 100 - 200X 4,0

9,2

16 4 poles

N8020760 A2LD 100 - 200D 10

38

2 poles

Discharge head
in meters

N8020770 A2LD 100 - 200C 12,5 44,5

8,2 7,8 7,4

6,5

5,3 4,6

14,5 14,2 14 13,8 13,5 13,1 12,7 12,2 11 9,0 6,5


23,3 22 20,5 18,5 16 13,5 10,5 7

2 poles

N8020780 A2LD 100 - 200B 15

58

2 poles

N8020790 A2LD 100 - 200A 15

71

2 poles

N8020740 A2LD 100 - 200F 12,5

27

2 poles

32,1 31 29 27 24,5 22 19

N8020750 A2LD 100 - 200E 15

32

2 poles

37,3 36,5 35 33

26,2 25,5 24 22

20 17,5 15

12 8,6

27,8 27 25,5 23,5 21,5 19 16,5 13,8 10,8 7,5

29 28 26 24,5 22 20 17,5 14 11,3 7,5 3,5

31 28,5 26

Counterflanges not included

DN : Flanges

DN

n d holes e

DIMENSIONS AND WEIGHTS


Model

Motor

Flanges mm.

DNa
DNm
a

Dimensions mm.

Weight
(Kg)

A4LD 100 - 200 X

112

100 PN10 158

180

220

18

615

180

435

670

325

345

630

240

390

165

150

A4LD 100 - 200 Y

100

100 PN10 158

180

220

18

605

180

425

670

325

345

630

240

390

165

138

A4LD 100 - 200 Z

100

100 PN10 158

180

220

18

605

180

425

670

325

345

630

240

390

165

130

A4LD 100 - 200 W

90

100 PN10 158

180

220

18

535

180

355

670

325

345

630

240

390

165

110

A2LD 100 - 200 E

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 F

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 D

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 C

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 B

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 A

132

100 PN10 158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

84

A2LD - A4LD
Section view

17

18

18

3
10

16

18

10

12

16
9
13
15
8
4

11
1

Pump casing

10

Gasket

Inspection cover

11

Drain plug

Lantern - cover cap

12

Vent plug

Impeller

13

Spring washer

Baffle

14

Hexagonal nut

Shutter

15

Tab

Shutter pivot

16

Washer

Impeller nut

17

Motor

Mechanical seal

18

Screw

A2LD - A4LD

85

ACCESSORIES
BRASS UNIONS
CODE

DESCRIPTION

MATERIAL

UNION
(PIPE END)

RING NUT

B7012KKK

3/4F

1 1/2

B7016KKK

3/4F

1 1/4

1F

1 1/2

1F L

1 1/2

B7014KKK

1 1/4 M

1 1/2

B7015KKK

1 1/4 F

B7013KKK
Two brass unions
and gaskets

B7009KKK

MATERIAL

DESCRIPTION

CODE
B7058KKK

TYPE

To be
welded

B7098KKK
B7047KKK

Threaded
B7097KKK
B7059KKK

To be
welded

ZB901890

D
B7048KKK
B7050KKK

Threaded
DN

B7060KKK

Steel

B7075KKK
B7049KKK

To be
welded

ZB901950

100

14

DN 40

110

19

10-16

DN 40

100

14

11/2

110

19

10-16

11/2

110

14

DN 50

125

18

10-16

DN 50

110

14

125

18

10-16

130

14

DN 65

145

18

10-16

DN 65
21/2

18

10-16

21/2

150

19

DN 80

160

18

10-16

DN 80

150

18

160

18

10-16

To be
welded

170

19

DN 100

180

18

10-16

DN 100

To be
welded

210

18

10-16

DN 125

240

22

10-16

DN 150

ZB901900

ZB901930

DN

145

Threaded

B7078KKK

PN

B7054KKK

ZB901920

N F

14

To be
welded

B7062KKK

ZB901940

Kit including 2 circular flanges,


bolts and gaskets.

130

Threaded

B7061KKK

Brass

BLIND FLANGES
MATERIAL

INT

N F

G20

133,5

8,5

B7230KKK

G20

180

11

ZB901860

Fe 360

112

CODE
B7231KKK

DESCRIPTION

Blind flange

86

HOW TO CHOOSE PIPE UNIONS AND COUNTERFLANGES

BRASS UNIONS

ROUND FLANGES

10-16

10-16

10-16

B7048KKK

B7050KKK

B7059KKK

ZB901890

B7060KKK

10-16

10-16

6
B7054KKK

10-16

UNION (pipe end) /4F /4F 1F 1FL 1 /4M 1 /4F 1 /2 1 /2 DN 40 DN 40 2

BLIND FLANGES

ZB901940

B7049KKK

B7058KKK

B7098KKK

B7047KKK

B7075KKK

ROUND FLANGES

BRASS UNIONS
3

B7097KKK

ACCESSORY

BLIND FLANGES

2 DN 50 DN 50 DN 65 DN 65 2 /2 2 /2

3 DN 80 DN 80 DN 100 DN 100 DN 125 DN 150

16

16

B7062KKK

B7078KKK

ZB901930

B7230KKK

B7231KKK

10-16

ZB901860

ZB901920

ZB901950

10-16 10-16
ZB901900

B7015KKK

B7014KKK

B7009KKK

B7013KKK

B7016KKK

CODE

TYPE

B7012KKK

PN

B7061KKK

11/2 11/4 11/2 11/2 11/2 2

Ring nut

SR3 15
SR3 25

SR3 32
R2X 20
R2B 30
R2B 32/R2B 40
R2S (D) 32
R2S 40
R2S 40 F
R2S (D) 42 F
R2C/R4C (D) 40

R2CD 50-60/R4CD 50-30


R2C/R4C (D) 50

R2CD 65-60/R4CD 65-30


R2C/R4C (D) 65

R2C/R4C (D) 80 PN6

R2C/R4C (D) 80 PN16

R4C (D) 100 PN6

R4C (D) 100 PN16


R2T/R4T (D) 40

R4T (D) 50-30


R2T/R4T (D) 50

R4T (D) 65-30


R2T/R4T (D) 65

R2T/R4T (D) 80 PN6

R2T/R4T (D) 100 PN16

A2L/A4L (D) 65

A2L/A4L (D) 80
A2L/A4L (D) 100
A4L 125
A4L 150

87

R2T/R4T (D) 100 PN6

A2L/A4L (D) 50

R2T/R4T (D) 80 PN16

A2L/A4L (D) 40

50 Hz

www.francoferrucci.com

BELGIUM

ITALY

UNITED ARAB EMIRATES

Pentair Water

Pentair Pumps

Pentair Water Middle East

Industriepark Wolfstee,
Toekomstlaan 30
B-2200 HERENTALS
Tel. +32.14.25.99.11
Fax. +32.14.25.99.75
www.pentairwater.com

Via Masaccio, 13
56010 Lugnano (Pisa)
Tel. +39.050.71.61.11
Fax. +39.050.70.31.37
www.nocchi.it

Al Diyaffa Center, M Floor Office 104-105


P.O. Box 24670
Dubai, U.A.E.
Tel. +971.43.45.50.74
Fax. +971.43.45.51.04
www.pentairwater.com

Pentair Pumps
BP 92 Vedne - 84965
LE PONTET Cedex - AVIGNON
Tel. 04.90.480.880
Fax 04.90.480.888
www.nocchi.it

Pentair Water
140, avenue Roland Garros
78532 BUC CEDEX
Tel. +33.(0)1.39.24.15.00
Fax. +33.(0)1.39.56.03.90
www.pentairwater.com

GERMANY
Pentair Water
Wiesenstrae 6
Industriegebiet Nord
D-64347 Griesheim
Tel. +49615584170
Fax +496155841799

Via Brughiera 1 - 20010


PREGNANA MILANESE (MI)
Tel. +39.02.93.27.111
Fax. +39.02.93.27.1154
www.pentairwater.com

REPUBLIC OF SOUTH AFRICA


Pentair Water
P.O. Box 11325, Selcourt 1567,
15 Miller Road,
Nuffield, Springs - Gauteng
Tel. +27.11.818.5818
Fax +27.11.818.3710

RUSSIA
Pentair Pumps
4 Luchevoy Prosek
Exhibition Centre Sokolniki
Pav. 5, Off. 30 - Moscow
Tel.+7-095-913 90 22, 956 55 61
Fax +7-095-234 23 50
www.nocchi.ru

UNITED KINGDOM
Pentair Water Filtration
Daimler Drive, Cowpen Lane
Industrial Estate
Billingham - Cleveland, TS23 4DJ
Tel. +44 (0)1 642 370 616
Fax +44 (0)1.642.564.708

SPAIN
Pentair Water
MI I Fontanals 28, 08205
Sabadell - Barcelona
Tel +34 937 10 28 39
Fax +34 937 10 47 67

GB- 3 EDIZIONE 072006 - COD - NV260PB40

FRANCE

Pentair Water

Circulating pumps Catalogue

Circulating pumps Catalogue

You might also like