Safety I s al ways a no. 1 pri ori ty in substation design, operation and maintenance. There are numerous laws, rules, codes, etc. Governing safety requirements. The main mission of all these regulations is safeguarding of personnel from hazards arising from the installation, maintenance or operation of substation equipment.
Safety I s al ways a no. 1 pri ori ty in substation design, operation and maintenance. There are numerous laws, rules, codes, etc. Governing safety requirements. The main mission of all these regulations is safeguarding of personnel from hazards arising from the installation, maintenance or operation of substation equipment.
Safety I s al ways a no. 1 pri ori ty in substation design, operation and maintenance. There are numerous laws, rules, codes, etc. Governing safety requirements. The main mission of all these regulations is safeguarding of personnel from hazards arising from the installation, maintenance or operation of substation equipment.
To: genks_81@yahoo.com; Date: Monday, January 27, 2014 6:11 PM Technical articles receive 26,249 electrical engineers worldwide. Don't want to receive'em any more? Unsubscribe Here. Email not displaying correctly? View it in your browser. Published on J an 27, 2014 06:11 am by Edvard | Subscribe to Monthly Download Updates Downl oad - World Smart Grid Forum 2013 Recommendations Print https://us-mg5.mail.yahoo.com/neo/launch?retry_ssl=1#mail 1 of 4 1/28/2014 7:28 PM 6 Simple Rules to Ensure Substation Safety Importance of safety protection Another extremely important substation engineering aspect is associated with safety protection. It is fair to say that safety i s al ways a No. 1 pri ori ty in substation design, operation and maintenance. Unlike the case where a higher reliability required a larger investment, we cant put a price tag on safety since there is no such thing like working conditions being more or less safe. It should always be 100% safe to work at or visit the substation. There are numerous laws, rules, codes, etc. governing safety requirements; of the most important being IEEE Standard C2-2012. 2012 Nati onal El ectri cal Safety Code (NESC) The main mission of all these regulations is safeguarding of personnel from hazards arising from the installation, maintenance or operation of substation equipment. Safety standards contai n requi rements for: Enclosure of electrical equipment Rooms and spaces Illumination Floors, floor openings, passageways, stairs Print https://us-mg5.mail.yahoo.com/neo/launch?retry_ssl=1#mail 2 of 4 1/28/2014 7:28 PM Exits Installation of equipment: Protective grounding Guarding live parts Working space above electrical equipment Specific rules for installation of all typical substation equipment All these measures are based on common sense and the goal to provide a safe envi ronment for substati on personnel . 6 rules to provide substation safety Rule no. 1 (clearance) Enough clearance from energized parts should be provided to avoid accidental contact with them. If that cant be met, live parts should be guarded or enclosed. Rule no. 2 (minimum height) A mi ni mum hei ght from the ground to any ungrounded part of an electrical installation should be 8-6, so a person staying on the ground cant touch a substation element or its part which may become energized accidentally. For example, the bottom of a post insulator supporting an energized bus does not normally have any potential. However, if bus fl ashover to the ground over i nsul ator occurs, touching the bottom of the insulator may become unsafe. Thats why an 8 -6 di stance from the bottom of insulator to the ground should be provided. Rule no. 3 (illumination) There should be sufficient illumination for personnel to clearly see their surroundings and perform any work safely. Required illumination levels are specified in NESC [1]. Rule no. 4 (passageways) All passageways and stai rs should be wide enough for personnel to navigate them safely, adequate railing should be provided, and floor openings should have guard rails. Rule no. 5 (evacuation routes) Exits should be cl earl y marked and evacuation routes should be free from obstructi ons. Depending on the function of the building (for example, control house), it may require several exits to avoid personnel being trapped during equipment fault, fire, etc. Rule no. 6 (grounding, as always) All substation metallic structures, fences, and equipment tanks should be connected to a stati on ground gri d which should be designed to ensure that step and touch potential values are lower than the ones stipulated in the applicable standards. Print https://us-mg5.mail.yahoo.com/neo/launch?retry_ssl=1#mail 3 of 4 1/28/2014 7:28 PM Reference: Fundamentals of Modern Electrical Substations; Part 3: Electrical Substation Engineering Aspects by Boris Shvartsberg, Ph.D., P.E., P.M.P. Jump to original technical article at EEP - 6 Simple Rules to Ensure Substation Safety Category & Tags: Power Substation, Safety, clearance, evacuation routes, grounding, passageways, station ground grid, subsation, substation safety Subscribe to Monthly Download Updates Recently published technical articles: Dimensioning of Power Distribution Systems (2) Power Transformer Capacitance and Dissipation Factor Test Dimensioning of Power Distribution Systems (1) Power Transformer Turns Ratio Test Automatic transfer switch (ATS) between two low-voltage utility supplies Calculating the short-circuit current across the terminals of a synchronous generator 8 Main Disadvantages of HVDC Transmission U.S. Renewable Energy The Facts! Example of MV/LV network structure with dual fed main MV switchboard Share with your friends!
Copyright 2014 EEP - Electrical Engineering Portal, All rights reserved. You're receiving this newsletter because you opted in at our website EEP for receiving technical articles. Our mailing address is: EEP - Electrical Engineering Portal Murska 10 Belgrade 11000 Serbia Add us to your address book unsubscribe fromthis list | update subscription preferences Print https://us-mg5.mail.yahoo.com/neo/launch?retry_ssl=1#mail 4 of 4 1/28/2014 7:28 PM