Professional Documents
Culture Documents
<Desktop type>
MODEL
MA-EF503HS-U
MA-EF303HS-U
INSTRUCTION MANUAL
CONTENTS
Page
Maintenance
Troubleshooting.............................15
Specifications ...............(back cover)
Plasma deodorization
For odors that cannot be removed even with
activated charcoal
Troubleshooting
How to Use
Features
Before Using
Safety precautions
The following displays categorize the degree of danger when mishandled.
Always follow
Do not touch
Do not get wet
Do not use
near water
Remove the
power plug
WARNING
Do not repair,
disassemble or
modify.
AC120V
CAUTION
Do not allow the unit to intake
flammable gases.
Do not use where there is
accumulation of such flammable
gases (factories, hair salons, etc.).
Gas
Gas
Oil
Spr
ay
Before Using
Gas
Safety precautions
Oil
Precautions
This air purifier is for household use only. Do not use for business purposes.
When carrying
Turn the power switch to OFF,
unplug the unit, and carry the
unit by the handle.
Notes
How strong are the electromagnetic waves discharged by this air purifier?
The electromagnetic waves produced by this product are lower than mobile phones, and are harmless to the body
and medical equipment.
Can the unit remove odors of newly constructed houses?
The unit may not be able to completely remove odors if the discharge of odors is too much such as with new paint or
carpet glues.
Main unit
Odor sensor
Two AA type
batteries for the
Remote controller remote controller
Reset Switch
Control panel
Press after
replacing the filter.
Intake grill
Before Using
Air fan
Table stand
Grill-release button
Dust sensor
Detects polluted air such
as pollen, etc. 6~7
Spring clips
(On each side
of Plasma unit)
67
Handle
Exhaust air
port
Precautions
HEPA filter
Power cord
<Replacing>
Hook the tabs on the front
side of the table stand,
and then press in the rear
side of the stand.
Control panel
Plasma air deodorization
11
ON Plasma deodorization in
process
FlashingError 13
PLASMA
MICRO
DUST
ODOR
REPLACE FILTER
POLLEN
Remote sensor
How to use the
remote controller
Odor sensor
14
0.01
0.1
Pollen
10
100 (micron)
MICRODUST
POLLEN
Odor sensor
Dust sensor
MICRODUST
Using an optical sensor, the number of particles less than
approximately 1 micron is detected.
POLLEN
Using an optical sensor, the number of particles more than
approximately 1 micron is detected.
FAN
PLASMA
TIMER
11
function ON
HOUR
POLLEN
GUARD NORMAL
POWER
TIMER
FAN
AUTO
Operation
ON/OFF
POWER button
Turns the unit ON
Turns the unit OFF
10
FAN button
AUTO button
Effective usage
Effective usage
10
Before Using
AUTO
Operation switch
Turns the unit ON
Turns the unit OFF
For the best results from your product, install the unit where there is good air
circulation.
If you are
concerned
about
pollen
If you
are
concerned
about
smoke
10
Preparation
Setting the filters
Remove the plastics from the HEPA filter and the
activated charcoal filter before use.
Both sides
Remove
the plastic
3
Hold the spring
clips, and remove
one side at a time.
Caution
Remove the
plastic before
installing.
(White particles within the activated
charcoal filter are titanium oxide, not
mildew.)
Operation
Using the remote controller
HOUR
POLLEN
GUARD NORMAL
POWER
TIMER
FAN
ON/OFF
AUTO
POWER
POWER
AUTO
FAN
PLASMA
TIMER
Press
OFF
ON
beep, beep
beep, beeep
POWER
ON/OFF
MICRO
DUST
POLLEN
Remote controller
Do not cover the remote
sensor with cloths, etc.
If the main unit does not respond properly to the
signals from the remote controller, replace with
the new batteries.
Make sure the remote sensor and the remote
controller are in sight of one another.
ODOR
Before Using
Preparation
Press
MAX
MIN
Clean air
Dirty air
HOUR
POLLEN
GUARD NORMAL
POWER
TIMER
FAN
ON/OFF
AUTO
POWER
FAN
AUTO
FAN
PLASMA
TIMER
AUTO
AUTO
FAN
Press
one of the buttons
Press
one of the buttons
FAN
beep
beep
MIN or LOW
When sleeping
HIGH or MAX
When house cleaning
AUTO
POLLEN GUARD
NORMAL
POLLEN
GUARD NORMAL
10
The unit will return to the previously set mode even after turning the unit off.
The unit will return to the previously set mode even when reinserting the power plug or after having a power failure.
POWER
AUTO
FAN
PLASMA
TIMER
ON
OFF
beep
beeep
PLASMA
Press
HOUR
POLLEN
GUARD NORMAL
POWER
TIMER
FAN
AUTO
ON/OFF
POWER
TIMER
Press
beeep
Continuous
Operation
(Lamp off)
HOUR
AUTO
FAN
PLASMA
TIMER
TIMER
Press
Changing the airflow How to Use Plasma air deodorization/Off timer operation
11
WARNING
Maintenance
Monthly
Yearly
14
Monthly cleaning
For the best performance from your unit, clean approximately once a month.
2
Remove surrounding dust
using the nozzle brush of a
vacuum cleaner.
Intake grill
Remove dust
using a nozzle
brush of a
vacuum cleaner.
f
no
tio ow
c
e
l
Dir airf
Main unit
Dry-wipe with
a soft cloth.
For stubborn dirt,
wipe with a cloth
dampened with
water.
12
WARNING
Before cleaning the unit, turn off the power and
remove the power plug.
Electrical shock and/or injury may occur as a result.
Yearly cleaning
Clean at least once a year. Clean the Plasma unit if the Plasma deodorization lamp flashes.
2
Left side of
main unit
Push in
the lower
section.
13
Maintenance (continued)
Replacing the filters
The filter replacement lamp notifies you of the replacement period of the HEPA filter and the activated charcoal filter.
Replace both the HEPA filter and the activated charcoal filter at the same time.
Replacement period
Although the replacement period depends on
the usage environment and conditions, the
lamp will light after approximately 5 years
when using the unit on constant MIN fan
speed.
(In the case of MAX, the lamp will light in
approximately 1/4 the time.)
When the filter replacement lamp illuminates
When the HEPA filter becomes dirty and the
color is about the same as that indicated on
the label
Reset Switch
Set vertically.
(There is no front or back.)
12~13
Beep
Reset switch
Model
MAPR-E837HFT
Code no. 5D4 C06
To order parts, contact your dealer of purchase
or Mitsubishi Electric @ www.plasmapure.com
14
Troubleshooting
Cause
Symptom
Remedy
12~13
14
12~13
14
Plasma deodorization
lamp flashes
13
Symptom
Cause
During the Plasma deodorization, you may hear a small hissing noise or notice an ozone smell.
(The level of noise and degree of the smell of ozone will vary depending on the environment.
The generated ozone is of low concentration and is harmless to the body.)
Is the room too large?
Use the unit within the range of the applicable floor area.
If there is a large volume of dust or odor, it may
take some time for the air to become clean.
The sensitivity of the sensor differs depending on odor ingredients, and the
monitor display may at times remain unchanged.
The monitor lamp will flash until the sensors become stable, even if the
power is turned on immediately after inserting the power plug.
The sensor may at times respond to a breeze from air conditioners within
the room, and gases that are unnoticeable to the human smell.
Trouble- Troubleshooting
shooting
Should the problem persist after having checked the above list, stop using the unit, remove the power plug and contact
your dealer of purchase or Mitsubishi Electric.
15
Model
MA-EF503HS-U
Power supply
Power consumption
Airflow volume
Room size
Weight
Dimension
(HWD)
Power cord length
Safety devices
Accessories
MA-EF303HS-U
AC120V 60Hz
MAX
66W
36W
HIGH
28W
26W
MED
19W
19W
LOW
17W
17W
MIN
16W
16W
MAX
160 CFM
106 CFM
HIGH
102 CFM
90 CFM
MED
65 CFM
65 CFM
LOW
46 CFM
46 CFM
MIN
34 CFM
34 CFM
233 Sq.FT
13 ft 18 ft
155 Sq.FT
11 ft 14 ft
17.1lbs (7.6 kg)
15-3/4" 22-7/32" 7-7/8"
(400mm 564mm 200mm)
8.2 ft (2.5m)
Current fuse (2A), motor overheat protection device (operational temp: 212F (100C)),
abnormal electric discharge protection device
Remote controller (type AA battery 2)
Specifications