You are on page 1of 8

Hitec Power Protection

Ride Through systems


Ride through systems Diesel UPS systems
www.hitec-ups.com
Hitec Power Protection
What we do
frequency
variation
short
interruptions
sags
Quality
Power
RFI
spikes
transients
Mains
Hitec Rotary
UPS systems
C
u
s
t
o
m
e
r
s
Hitec Power Solutions
Your benefits
Turnkey solutions for continuous, high quality power
Reliability: 100% uptime mission critical processes
Over 50 years of experience with rotary UPS solutions
Proven track record in different industries
Core of the solution: Rotary UPS system
Energy & space efficient system
Environmental friendly system (battery free)
Low investment, high quality, cost-efficient operation
Lowest Total Cost of Ownership
Global delivery, installation and support
Q1 Q2
Q3
Mains Load
1500 RPM 50Hz
1800 RPM 60Hz
Hitec Ride Through system
The principle
Hitec Ride Through system
System build up
Flywheel Electro Magnetic Coupling Generator
15 sec ride through time Rotary
filter
Load
Continuous environmental-friendly power solution
Acts as continuous power conditioner
Battery free
Low investment, beneficial life cycle costs
High output values
Single unit modules 400, 750, 1250 kVA
Parallel configuration Up to 30 MVA
Output voltage
LV 380 .. 480 V, 50/60 Hz
MV at request
Complies with IEC 88528-11 classification G3
(controls, IT and telecom)
Ride Through system
Specifications
Hitec Ride Through system
Applications
Secure continuity mission-critical processes
Avoidance of down time
Delivery of quality power secured
Protect against short power disturbances
95% last less than few seconds
RT system acts as voltage/frequency filter
RT system delivers voltage improvement
Power factor improvement
Additional to existing power infrastructure
Complementary to existing gen-sets
Enabling full DUPS functionality
Profitable investment even when costs/risks of
downtime are moderate
System operation
Mains operation
Main power flow
Q2 Q1
AC
DC
AVR
active power provided by mains
Alternator controls and maintains load voltage
IC excitation off (RT system follows mains frequency)
Keep kinetic energy storage charged
AC
AC
Q3
mains
load
1
1
2
3
2
3
4
4
System operation
Ride Through operation
Main power flow
Q2 Q1
AC
DC
AVR
RT power module provides active power
Alternator controls load voltage (reactive power)
IC excitation on (RT system controls load frequency)
kinetic energy storage recharge is switched off
AC
AC
Q3
mains
load
1
1
2
3
2
3
4
4
System operation
Transfer Ride Through to mains operation
Main power flow
Q2 Q1
AC
DC
AVR
RT power module provides active power
Alternator controls load voltage (reactive power)
IC excitation on (RT system synchronizes load to mains)
kinetic energy storage recharge is switched off
AC
AC
Q3
mains
load
1
1
2
3
2
3
4
4
synchronization
System operation
Mains operation
Main power flow
Q2 Q1
AC
DC
AVR
active power provided by mains
Alternator controls and maintains load voltage
IC excitation off (RT system follows mains frequency)
Recharge kinetic energy storage
AC
AC
Q3
mains
load
1
1
2
3
2
3
4
4
recharge
Plug & play system
Easy installation
Small footprint, reduced floor space requirements
Requires modest environmental conditions
No need dedicated climate controlled battery room
No special installation requirements (e.g. exhaust,
fuelling systems)
Easy to parallel
Available as containerized system
Plug & play system
Easy maintenance & operation
Use of long-time proven technology and components
Simplicity of design
No re-investment in batteries every 3 5 years
No chemical waste
Long technical lifetime (no power electronics)
System integrated Condition Monitoring
Easy access touch screen (HMI)
Global 24/7 support from our helpdesk
Remote monitoring software
Hitec Rentals
Discover the power of our Ride Through Systems
Contact our rental service:
+31-546-589589
info@hitec-ups.com
Thank you for your interest
Ride through systems Diesel UPS systems
www.hitec-ups.com

You might also like