You are on page 1of 6

OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
1


Evolution Rotator Drive Systems






This document is intended to provide operating instructions for the Evolution Rotator Drive
Systems line of Evolution Oil Tool products. This guide is property of Evolution Oil Tools Inc.
and is provided to the customer for information purposes only. It is requested that the document
not be reproduced in any way, in whole or in part, or distributed without the express written
consent of Evolution Oil Tools Inc. The document is uncontrolled if printed.

OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
This document is intended to provide operating instructions for the Evolution
Rotator Drive Systems line of Evolution Oil Tool products. This guide is
property of Evolution Oil Tools Inc. and is provided to the customer for
information purposes only. It is requested that the document not be
reproduced in any way, in whole or in part, or distributed without the express
written consent of Evolution Oil Tools Inc. The document is uncontrolled if
printed.
2

The Evolution line of tubing rotators, including the CTR, E-Plus and E-Style models all require a drive
system to operate. There are three available systems: manual drive, mechanical drive, and, electrical
drive.


Progressive Cavity
Pump (PCP) Beam Pump

Manual Drive


Mechanical Drive


Electrical Drive



Recommended


Possible

Rotator Input vs. Output



Input
Rotations
Output
Rotations
Input in
Degrees
Output In
Degrees
Gear
Ratio of
Drive
Gear
Ratio of
Rotator
Motor
RPM
(Rotations
per
Minute)
Motor
RPD
(Rotations
Per Day)
Rotator
Speed
RPM
Rotator
Speed
RPD
Manual Drive 70 1 360 5.14286 Direct 70 to 1 na na na na
Mechanical
Drive
700 1 360 0.51429 10 to 1 70 to 1 na na na na
Electric Drive 1,680,000 1 360 0.00021 24000 to 1 70 to 1 1,750 2,520,000 0.001042 1.50

OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
This document is intended to provide operating instructions for the Evolution
Rotator Drive Systems line of Evolution Oil Tool products. This guide is
property of Evolution Oil Tools Inc. and is provided to the customer for
information purposes only. It is requested that the document not be
reproduced in any way, in whole or in part, or distributed without the express
written consent of Evolution Oil Tools Inc. The document is uncontrolled if
printed.
3

Manual Drive
The Manual Drive system allows the operator to rotate the tubing on a periodic basis. A daily operation
of three or four (3-4) rotations is recommended. For exact turning ratios, see the table on page 2. The
Manual Drive system is mostly used with progressive cavity pump (PCP) installations.

OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
This document is intended to provide operating instructions for the Evolution
Rotator Drive Systems line of Evolution Oil Tool products. This guide is
property of Evolution Oil Tools Inc. and is provided to the customer for
information purposes only. It is requested that the document not be
reproduced in any way, in whole or in part, or distributed without the express
written consent of Evolution Oil Tools Inc. The document is uncontrolled if
printed.
4

Mechanical Drive
Installation
Attach Walking Beam Clamp approximately 6" from pivot point on pump jack. Set Ratchet Handle to do
1 or 2 clicks each stroke of the pump jack. Adjust cable length using the cable adjustment screw at the
end of the Ratchet Handle Clevis.
Maintenance
Check oil once per year. Fill with 80w90 Gear Oil.
Grease Ratchet Handle once every six months.


OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
This document is intended to provide operating instructions for the Evolution
Rotator Drive Systems line of Evolution Oil Tool products. This guide is
property of Evolution Oil Tools Inc. and is provided to the customer for
information purposes only. It is requested that the document not be
reproduced in any way, in whole or in part, or distributed without the express
written consent of Evolution Oil Tools Inc. The document is uncontrolled if
printed.
5

Electrical Drive
The Electrical Drive System is used with progressive cavity pumps and beam pumps that have an
electric surface drive. The drive system is run by a 1750 rpm explosion proof 12V, 110V/220V or 460V
motor. For turning ratios, see the table on page 2.


OPERATING INSTRUCTIONS

Product -
Evolution Rotator Drive Systems
261-10-OI-Rev-A
This document is intended to provide operating instructions for the Evolution
Rotator Drive Systems line of Evolution Oil Tool products. This guide is
property of Evolution Oil Tools Inc. and is provided to the customer for
information purposes only. It is requested that the document not be
reproduced in any way, in whole or in part, or distributed without the express
written consent of Evolution Oil Tools Inc. The document is uncontrolled if
printed.
6



If you have any other questions or concerns, do not hesitate to contact us:

www.eotools.com
Canada

#3, 1820 30
th
Avenue NE
Calgary, Alberta, Canada
T2E 7M5
Toll Free: 1-800-265-TOOL (8665)
Main: (403) 243-1442
Fax: (403) 258-2614


6415A 63 St. Close
Lloydminster, Alberta
Tel: 780-875-1570
Cell: 780-522-8294
Cell: 780-870-1126


4512 81 Ave
Edmonton, Alberta
Tel: 587-758-9091
Cell: 780-919-1722
Cell: 780-893-1019


US

P.O. Box 5363
2908 Coffey Street
Victoria, Texas 77903
Main: (361) 575-7900
Fax: (361) 575-8081

3400 Kermit Hwy
Odessa, Texas 79764
Tel: 432-337-7900
Fax: 432-337-7901
Cell: 432-638-7902