You are on page 1of 18

Guida Tecnica:

Potenze
Technical Guide:
Ratings Book

Mecc Alte SpA

Via Roma
20 36051 Creazzo
Vicenza ITALY
T: +39 0444 396111
F: +39 0444 396166
E: info@meccalte.it
aftersales@meccalte.it

United Kingdom

Spain

Mecc Alte Espaa S.A.


C/ Rio Taibilla, 2
Polig. Ind. Los Valeros
03178 Benijofar (Alicante)
T: +34 (0) 96 6702152
F: +34 (0) 96 6700103
E: info@meccalte.es
aftersales@meccalte.es

Mecc Alte U.K. LTD


6 Lands End Way
Oakham
Rutland
T: +44 (0) 1572 771160
F: +44 (0) 1572 771161
E: info@meccalte.co.uk
aftersales@meccalte.co.uk

Germany

France

Far East

Mecc Alte International S.A.


Z.E.La Gagnerie
16330 ST.Amant De Boixe
T: +33 (0) 545 397562
F: +33 (0) 545 398820
E: info@meccalte.fr
aftersales@meccalte.fr

Mecc Alte Generatoren GmbH


Ensener Weg 21
D-51149 Kln
T: +49 (0) 2203 503810
F: +49 (0) 2203 503796
E: info@meccalte.de
aftersales@meccalte.de

Mecc Alte (F.E.) PTE LTD


19 Kian Teck Drive
Singapore 628836
T: +65 62 657122
F: +65 62 653991
E: info@meccalte.com.sg
aftersales@meccalte.com.sg

India

Mecc Alte India PVT LTD


Plot NO: 1, Sanaswadi
Talegaon
Dhamdhere Road
Taluka: Shirur, District:
Pune - 412208
Maharashtra, India
T: +91 2137 619600
F: +91 2137 619699
E: info@meccalte.in
aftersales@meccalte.in

U.S.A. and Canada

Mecc Alte Inc.


1229 Adam Drive
McHenry, IL, 60051
T: +1 815 344 0530
F: +1 815 344 0535
E: info@meccalte.us
aftersales@meccalte.us

China

Mecc Alte Alternator Haimen LTD


755 Nanhai East Rd
Jiangsu HEDZ 226100 PRC
T: +86 (0) 513 82325758
F: +86 (0)513 82325768
E: info@meccalte.cn
aftersales@meccalte.cn

Australia

Mecc Alte Alternators PTY LTD


10 Duncan Road, PO Box
1046
Dry Creek, 5094, South
Australia
T: +61 (0)8 8349 8422
F: +61 (0)8 8349 8455
E: info@meccalte.com.au
aftersales@meccalte.com.au

www.meccalte.com
MAUK: 22.10.2012 | V04

E309573

Contents
Ratings Definitions

ECO & ECP Brushless Alternators


with AVR 50 or 60Hz 1Phase or 3Phase
4 Pole Industrial | ECO & ECP /4
4 Pole 50Hz Ratings
AVR Controlled Ratings 3ph 400v or 200v 50Hz 1500rpm

AVR Controlled Ratings 3ph 380v 50Hz 1500rpm

AVR Controlled Ratings 3ph 440v or 220v 50Hz 1500rpm

AVR Controlled Ratings 3ph 380-415v 50Hz 1500rpm - broad voltage

AVR Controlled Ratings 1ph 220v 50Hz 1500rpm

10

AVR Controlled Ratings 1 phase dedicated 220v winding 50Hz 1500rpm

11

4 Pole 60Hz Ratings


AVR Controlled Ratings 3ph 480v or 240v 60Hz 1800rpm

12

AVR Controlled Ratings 3ph 440v or 220v 60Hz 1800rpm

13

AVR Controlled Ratings 3ph 416-480v 60Hz 1800rpm - broad voltage

14

AVR Controlled Ratings 3ph 380v 60Hz 1800rpm

15

AVR Controlled Ratings 3ph 380v dedicated 60Hz 1800rpm

16

AVR Controlled Ratings 3ph dedicated 600v 60Hz 1800rpm

17

AVR Controlled Ratings 1ph 240v 60Hz 1800rpm

18

AVR Controlled Ratings 1ph dedicated 240v 60Hz 1800rpm

19

CTP & ECSO Alternators with Transformer


Control 50 or 60Hz 1Phase or 3Phase
Transformer Controlled | CTO & ECSO
Transformer Regulated Alternator ratings 2 and 4 pole

20

ECP Lister T Connection Brushless Alternators


with AVR 50 or 60Hz 1Phase or 3Phase
Lister Petter T Range | ECO28
Alternators to fit Lister TS/TR

21

LT3 Brushless Alternators


with Capacitor 50 or 60Hz 1Phase
Lighting Tower | LT3
LT3 Lighting Tower Style 4 pole

22

NPE Brushless Alternators


with AVR 50 or 60Hz 1Phase or 3Phase
Space Saver | NPE
NPE Alternator Range 4 Pole

23

NPE Alternator Range 2 Pole

24

Contents (Continued)

Rating Definitions:
TE34 IP54 Brushless Alternators with AVR 50 or 60Hz
Totally Enclosed | TE34
Totally Enclosed Alternators

25

400Hz Brushless Alternators with


AVR 50 or 60Hz 1Phase or 3Phase
400Hz | HC
HC Alternator 14/20/24 Pole 400Hz

26

Standby Rating is selected for supplying emergency


power for the duration of normal power interruption.
Overload on this rating is not allowed.

Prime Rating is the maximum power available at a


variable load for an unlimited number of hours: it
allows the possibility of a 10% overload.

From the generator point of view, if the emergency


power is required continuously for more than one
hour sizing is in accordance with 150/40 or 163/27
conditions. Also, if the overload duration is less than one
hour, then the generator accepts 10% overload above
Prime Ratings for 125/40 or the 125/27 ratings.

This is equivalent to Prime Power in accordance


with ISO8528 and Overload Power in accordance
with ISO3046, AS2789, DIN6271, and BS5514. From
the generator point of view, it is sized according to
the class B, F, H temperature rise requirements or
125/27 rating.

In the Ratings Book you can find ratings for:

In the Ratings Book you can find ratings for:

150/40: Peak continuous ratings according to

80/40: this condition is equivalent to Class B

temperature rise. 10% overload on 1 hour over 6


hours is allowed.

163/27 : Emergency peak continuous rating, not

2 Pole Industrial | ECO/2


27

S15,S16 & S20 Brushless Alternators with Capacitor and


Optional AVR or Brushed with AVR, 50 or 60Hz
2 Pole Portable 1PH | S15, S16, S20
2 Pole Portable Ratings Single Phase

Prime Rating

ISO8528-3.

ECO & ECP Brushless Alternators


with AVR 50 or 60Hz 1Phase or 3Phase
2 Pole Industrial Ratings

Standby Rating

28

defined in ISO specification. Suitable for stand-by


sizing only.
The ratings are then suitable for supplying continuous
electrical power, at variable load, for the duration
of any utility power failure. These ratings allow
temperature to rise above the temperature rise class
H limit which can result in a shorter insulation life.
The 10% overload is not available at these ratings.

105/40: this condition is equivalent to Class F

temperature rise. 10% overload on 1 hour over 6


hours is allowed.
125/40: this condition is equivalent to Class H

temperature rise. 10% overload on 1 hour over 6


hours is allowed.
125/27: ratings at this condition are equivalent to

those listed for the 150/40 condition if not listed.


10% overload on 1 hour over 6 hours is allowed.

T16 & T20 Brushed Alternators with Transformer


or Brushed with AVR, 50 or 60Hz

We suggest that customers contact the local Mecc


Alte Sales representative for guidance on generator
selection.

2 Pole Portable 3PH | T16, T20


2 Pole Portable Ratings Three Phase

29

Additional Information
Wiring Connection Diagram

30

SAE Coupling and Mounting Guide

32

Environmental Considerations

33

ECO & ECP Brushless Alternator


with AVR 50 or 60Hz 1Phase or 3Phase
4 Pole Marine | ECO & ECP
For marine Alternator Range please refer to Marine Ratings Book

AVR Controlled Ratings 3ph 400v or 200v 50Hz 1500rpm

AVR Controlled Ratings 3ph 380v 50Hz 1500rpm

4 Pole | 50Hz | 3Phase

4 Pole | 50Hz | 3Phase

Voltage:

400 or 200

Voltage:

380 or 190

RPM:

1500

RPM:

1500

Insulation:

Class H

Insulation:

Class H

kVA @ Temp. Rise / Ambient C/ 0.8 PF

kVA @ Temp. Rise / Ambient C/ 0.8 PF

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/27

125/40

105/40

80/40

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

7
8.8
11.8
14.5
16
18
21.5
26.5
32.5
39
48
56
71
83
95
116
143
164
175
196
220
250
275
330
370
437
491
546
601
670
735
779
874
1016
1201
1420
1520
1620
1780

6.8
8.3
11.4
14
15.5
17.5
20.5
25.5
30.5
36.7
46
52.5
65.5
78
90
110
137
158
169
188
211
237
264
315
360
417
468
521
576
640
700
740
840
975
1150
1358
1470
1552

6.8
8.3
11.4
14
15.5
17.5
20.5
25.5
30.5
36.7
46
52.5
65.5
78
90
110
138
158
169
188
211
237
264
315
360
417
468
521
567
640
700
740
840
975
1150
1358
1470
1552

6.5
8
11
13.5
15.0
17
20
25
30
35
42.5
50
63
75
85
105
130
150
160
180
200
225
250
300
350
400
450
500
550
620
680
720
800
930
1100
1300
1400
1500

6
7.5
10
12.5
14
16
18.5
23
26
33
39
48
60
67
77
95
118
136
145
170
185
207
230
275
320
370
410
450
500
560
630
660
730
850
1000
1200
1280
1350

5.3
6.4
8.8
10.8
12
13.6
16
20
24
28
34
40
52
60
68
84
104
120
128
144
160
180
200
240
280
320
360
400
440
496
544
576
640
744
880
1040
1120
1200

ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

3440
3870
4260
4380

12
12
12
12

DER1
DER1
DER1
DER1

1944
2268
2480
2700

1700
1863
2173
2380
2588

1700
1863
2173
2380
2588

1650
1800
2100
2300
2500

1480
1600
1900
2050
2250

1320
1440
1680
1840
2000

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

7
8.8
11.8
14.5
16
18
21.5
26.5
32.5
39
48
56
71
83
95
116
143
164
175
196
220
250
278
330
370
438
491
546
601
670
735
779
874
1016
1201
1420
1520
1620
1780
1944
2268
2480
2700

6.8
8.3
11.4
14
15.5
17.5
20.5
25.5
30.5
36.7
46
52.5
65.5
78
90
111
138
158
169
188
211
238
264
315
360
417
468
521
567
640
700
740
840
975
1150
1358
1470
1552
1700
1863
2173
2380
2588

6.5
8
11
13.5
15
17
20
25
30
35
42.5
50
63
75
85
105
130
150
160
180
200
225
250
300
350
400
450
500
550
620
680
720
800
930
1100
1300
1400
1500
1650
1800
2100
2300
2500

6.3
7.5
10
12.5
14
16
18.5
23
26
33
37
39
60
67
78
95
118
136
145
170
185
208
230
275
320
370
410
450
500
560
630
660
730
850
1000
1200
1280
1350
1480
1600
1900
2050
2250

5.3
6.4
8.8
10.8
12
13.6
16
20
24
28
34
40
52
60
68
84
104
120
128
144
160
180
200
240
280
320
360
400
440
496
544
576
640
744
880
1040
1120
1200
1320
1440
1680
1840
2000

All machines have an auxiliary winding standard with 300% short circuit capability.

All machines have an auxiliary winding standard with 300% short circuit capability.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

6 | www.meccalte.com

Technical Guide: Ratings Book | 7

AVR Controlled Ratings 3ph 440v or 220v 50hz 1500rpm

AVR Controlled Ratings 3ph 380-415/190-208 50Hz 1500rpm - Broad Voltage

4 Pole | 50Hz | 3Phase

4 Pole | 50Hz | 3Phase

Voltage:

440 or 220

Voltage:

RPM:

1500

RPM:

1500

Insulation:

Class H

Insulation:

Class H

380-415/190-208 | Broad Voltage

kVA @ Temp. Rise / Ambient C/ 0.8 PF

kVA @ Temp. Rise / Ambient C/ 0.8 PF

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

5.9
7.4
9.6
11.9
12.8
16.4
19.4
NA
NA
31
38
45
58
78
78
94
120
136
175
180
209
234
253
319
360
404
459
503
546
616
681
NA
754
918
1093
1349
NA
NA
NA
NA
NA
NA
NA

5.6
7
9.4
11.4
12.4
16
18.5
NA
NA
30
36
43
56
74
75
90
116
131
140
173
200
221
243
305
350
389
441
483
525
598
661
NA
725
883
1050
1296
NA
NA
NA
NA
NA
NA
NA

5.5
6.8
9
11
12
15.5
18
NA
NA
28
34
40
53
70
70
85
110
125
150
165
190
210
230
290
340
370
420
460
500
570
630
NA
690
840
1000
1235
NA
NA
NA
NA
NA
NA
NA

5
6.4
8
10
10.5
14.5
17
NA
NA
26
32
38
48
56
63
78
99
113
135
155
175
190
215
265
310
343
385
414
454
515
585
NA
610
770
910
1140
NA
NA
NA
NA
NA
NA
NA

4.4
5.4
7.3
8.8
9.6
12.4
14.4
NA
NA
23
28
33
43
56
56
68
88
100
120
133
153
168
184
233
273
296
336
368
400
456
504
NA
553
673
800
988
NA
NA
NA
NA
NA
NA

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

7
8.8
11.8
14.5
16
18
21.5
26.5
29.9
39
48
56
71
83
95
116
143
164
175
196
220
250
275
330
370
438
490
546
590
670
735
768
874
1016
1201
1420
1450
1620
1780
1944
2268
2480
2700

6.8
8.3
11.4
14
15.5
17.5
20.5
25.5
28.9
36.7
46
52.5
65.5
78
90
111
138
158
168
188
210
238
264
315
360
417
468
521
567
640
700
740
840
975
1150
1358
1400
1552
1700
1863
2173
2380
2588

6.5
8
11
13.5
15
17
20
25
28
35
42.5
50
63
75
85
105
130
150
160
180
200
225
250
300
350
400
450
500
540
620
680
710
800
930
1100
1300
1330
1500
1650
1800
2100
2300
2500

6.3
7.5
10
12.5
14
16
18.5
23
25
33
37
48
60
67
78
95
118
136
145
170
185
208
230
275
320
370
410
450
490
560
630
650
730
850
1000
1200
1210
1350
1480
1600
1900
2050
2250

5.3
6.4
8.8
10.8
12
13.6
16
20
22.4
28
34
40
52
60
68
84
104
120
128
144
160
180
200
240
280
320
360
400
433
496
544
568
640
744
880
1040
1064
1200
1320
1440
1680
1840

NA

All machines have an auxiliary winding standard with 300% short circuit capability.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

8 | www.meccalte.com

2000

All machines have an auxiliary winding standard with 300% short circuit capability.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

Technical Guide: Ratings Book | 9

AVR Controlled Ratings 1Ph Reconnected Winding 50Hz 1500rpm

AVR Controlled Ratings 1phase Dedicated Winding 50Hz 1500rpm

4 Pole | 50Hz | 1Phase

4 Pole | 50Hz | 1Phase

Voltage:

220/230/240 110/115/120 | Reconnected

Voltage:

RPM:

1500

RPM:

1500

Insulation:

Class H

Insulation:

Class H

220/230/240 Volts kW @ 1.0 PF

230V 1.0
PF Eff%

220/230/240 Volts kVA @ 0.8 PF

230v 0.8
PF Eff%

220/230/240 110/115/120 | Dedicated

220/230/240 Volts kW @ 1.0 PF

230V 1.0
PF Eff%

220/230/240 Volts kVA @ 0.8 PF

230v 0.8
PF Eff%

MODEL

WEIGHT (kg)

LEADS

AVR

150/40

125/40

105/40

150/40

125/40

105/40

MODEL

WEIGHT (kg)

LEADS

AVR

150/40

125/40

105/40

150/40

125/40

105/40

ECP3-1S/4

63

12

DSR

4.5

4.4

4.1

75.4

4.1

3.7

73.4

ECP3-1S/4

63

12

DSR

5.1

4.6

75.4

4.6

4.5

4.2

73.4

ECP3-2S/4

70

12

DSR

5.7

5.5

5.1

77.4

5.2

4.7

75.4

ECP3-2S/4

70

12

DSR

6.2

5.6

77.4

5.6

5.4

5.0

75.4

ECP3-1L/4

82

12

DSR

7.7

7.5

6.8

78.9

6.9

6.5

6.1

76.9

ECP3-1L/4

82

12

DSR

8.8

8.5

7.7

78.9

7.7

7.5

6.9

76.9

ECP3-2L/4

91.5

12

DSR

9.3

8.3

79.4

8.3

7.4

77.4

ECP3-2L/4

91.5

12

DSR

10.3

10

9.3

79.4

9.3

8.4

77.4

ECP3-3L/4

96

12

DSR

10.3

10

9.1

79.6

9.3

8.2

77.6

ECP3-3L/4

96

12

DSR

11.3

11

9.8

79.6

10.3

10

9.2

77.6

ECP28-S/4

107

12

DSR

11.8

11.5

10.7

81.1

10.8

10.5

9.8

79.1

ECP28-S/4

107

12

DSR

12.8

12.5

11.7

81.1

11.6

11.3

10.6

79.1

ECP28-M/4

122

12

DSR

13.8

13.5

12.3

81.4

12.2

12

11

79.4

ECP28-M/4

122

12

DSR

14.8

14.5

13.2

81.4

13.3

13

12

79.4

ECP28-2L/4

139

12

DSR

16.7

16.5

15.1

82.1

15.2

15

13.7

80.1

ECP28-2L/4

139

12

DSR

18.3

18

16.3

82.1

16.4

16

14.8

80.1

ECP28-VL/4

165

12

DSR

19.5

19

17

82.6

17.5

17

15

80.6

ECP28-VL/4

165

12

DSR

21.6

21

19

82.6

19.5

19

17

80.6

ECO32-2S/4

199

12

DSR

25

23.5

22

82.7

22

21

20

80.7

ECO32-2S/4

199

12

DSR

31

30

28

82.7

27

26

24

80.7

ECO32-3S/4

214

12

DSR

29

26.5

25

83.4

25

24

23

81.4

ECO32-3S/4

214

12

DSR

34

33

30

83.4

29

28

26

81.4

ECO32-1L/4

248

12

DSR

35

33

32

84.0

32

30

29

82.0

ECO32-1L/4

248

12

DSR

39

38

34

84.0

34

34

31

82.0

ECO32-2L/4

282

12

DSR

42

40

38

84.7

38

36

34

82.7

ECO32-2L/4

282

12

DSR

43

42

38

84.7

39

38

33

82.7

ECO32-3L/4

298

12

DSR

48

45

42

84.8

42

41

38

82.8

ECO32-3L/4

298

12

DSR

47.1

46

43

84.8

43.1

42

39

82.8

ECP34-1S/4

341

12

DSR

60

59

55

84.8

55

53

50

82.8

ECP34-1S/4

341

12

DSR

67

65

61

84.8

61

59

56

82.8

ECP34-2S/4

419

12

DSR

64

62

56

86.2

58

56

51

84.2

ECP34-2S/4

419

12

DSR

71

68

62

86.2

64

62

56

84.2

ECP34-1L/4

445

12

DSR

73

71

65

87.2

66

64

58

85.2

ECP34-1L/4

445

12

DSR

82

79

72

87.2

73

71

65

85.2

ECP34-2L/4

491

12

DSR

85

83

74

88.1

75

74

65

86.1

ECP34-2L/4

491

12

DSR

94

92

82

88.1

84

82

72

86.1

ECP34-3L/4

495

12

DSR

87.0

85

76

88.1

78

76

63

86.1

ECP34-3L/4

495

12

DSR

NA

NA

NA

NA

NA

NA

ECO38-1SN/4

510

12

DSR

87

85

76

86.0

78

76

63

84.0

ECO38-1SN/4

510

12

DSR

NA

NA

NA

NA

NA

NA

ECO38-2SN/4

560

12

DSR

89

86

79

86.6

82

79

72

84.6

ECO38-2SN/4

560

12

DSR

99

96

87

86.6

91

88

80

84.6

ECO38-3SN/4

590

12

DSR

100

98

88

86.9

91

89

81

84.9

ECO38-3SN/4

590

12

DSR

112

108

98

86.9

101

98

90

84.9

ECO38-1LN/4

680

12

DSR

116

113

101

87.4

104

101

89

85.4

ECO38-1LN/4

680

12

DSR

129

125

112

87.4

116

113

99

85.4

ECO38-2LN/4

765

12

DSR

131

128

116

87.8

116

113

103

85.8

ECO38-2LN/4

765

12

DSR

146

142

129

87.8

129

125

114

85.8

ECO38-3LN/4

905

12

DSR

154

150

136

87.5

135

131

120

85.5

ECO38-3LN/4

905

12

DSR

172

167

151

87.5

150

146

133

85.5

ECO40-1S/4

1040

12

DER1

199

188

173

87.5

188

176

165

85.5

ECO40-1S/4

1040

12

DER1

221

208

192

87.5

208

196

183

85.5

ECO40-2S/4

1118

12

DER1

225

210

195

87.6

214

203

180

85.6

ECO40-2S/4

1118

12

DER1

250

233

217

87.6

238

225

200

85.6

*ECO40-3S/4

1171

12

DER1

244

236

210

87.7

229

225

199

85.7

ECO40-3S/4

1171

12

DER1

271

263

233

87.7

254

250

221

85.7

ECO40-1L/4

1324

12

DER1

270

259

236

87.9

255

244

225

85.9

ECO40-1L/4

1324

12

DER1

300

288

263

87.9

283

271

250

85.9

*ECO40-1.5L/4

1380

12

DER1

304

293

263

88.0

285

274

248

86.0

ECO40-1.5L/4

1380

12

DER1

338

325

292

88.0

317

304

275

86.0

ECO40-2L/4

1586

12

DER1

334

323

300

88.0

311

300

278

86.0

ECO40-2L/4

1586

12

DER1

371

358

333

88.0

346

333

308

86.0

*ECO40-VL/4

1693

12

DER1

353

338

315

88.1

334

323

300

86.1

ECO40-VL/4

1693

12

DER1

392

375

350

88.1

371

358

333

86.1

*120/115/110 V not available on these three Models.

All machines have an auxiliary winding standard with 300% short circuit capability.

All machines have an auxiliary winding standard with 300% short circuit capability.

Zigzag, Delta, and Double Delta single phase connections available.

Consult Factory to choose for your application.

Consult Factory to choose for your application.

Ratings measured with copper damper cage.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

10 | www.meccalte.com

Technical Guide: Ratings Book | 11

AVR Controlled Ratings 3ph 480v or 240v 60Hz 1800rpm

AVR Controlled Ratings 3ph 440v or 220v 60Hz 1800rpm

4 Pole | 60Hz | 3Phase

4 Pole | 60Hz | 3Phase

Voltage:

480 or 240

Voltage:

RPM:

1800

RPM:

1800

Insulation:

Class H

Insulation:

Class H

440 or 220

kVA @ Temp. Rise / Ambient C/ 0.8 PF

kVA @ Temp. Rise / Ambient C/ 0.8 PF

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/27

125/40

105/40

80/40

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

8.4
10.5
14.3
17.5
19.3
21.5
25.5
31.8
38.4
47
57
67
83.5
100
114
139
171
196
209
236
264
300
330
396
444
525
590
656
722
805
882
935
1050
1220
1442
1704
N.A.
1836
2140

8
10
13.8
16.9
18.8
21
24.6
30.6
36.6
44
54
63
78.5
93.7
108
132
165
189
202
230
253
284
316
378
432
500
563
625
680
770
840
890
1008
1170
1380
1630
N.A.
1766

8
10
13.8
16.9
18.8
21
24.6
30.6
36.6
44
54
63
78.5
93.7
108
132
165
189
202
230
253
284
316
378
432
500
563
625
680
770
840
890
1008
1170
1380
1630
N.A.
1766

7.8
9.6
13.2
16.2
18.0
20.4
24
30
36
42
51
60
75.5
90
102
126
156
180
192
220
240
270
300
360
420
480
540
600
660
744
816
865
960
1116
1320
1560
N.A.
1700

7.2
9
12
15
16.5
19
22
27.5
32
40
49
58
72.5
84
92
114
141
163
173
205
220
250
280
330
385
440
490
540
600
672
756
800
870
1020
1200
1440
N.A.
1530

6.1
7.5
10.6
13
14.4
16.3
19.1
23.8
28.8
34
40
48
61
72
81
101
125
144
154
175
193
216
240
288
336
384
433
480
528
595
653
693
768
893
1056
1248
N.A.
1360

ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

3440
3870
4260
4380

12
12
12
12

DER1
DER1
DER1
DER1

2332
2430
2699
3240

2040
2236
2328
2590
3105

2040
2236
2328
2590
3105

1980
2160
2250
2500
3000

1780
1920
2036
2228
2700

1584
1728
1800
2000
2400

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

8.4
10.5
14.3
17.5
19.3
19.8
25
29
38
47
57
67
78.5
95
114
139
159
186
199
240
264
300
330
374
444
491
556
634
689
756
844
935
1049
1158
1376
1620
1824
1846
2050
2214
2581
2855
3068

8
10
13.8
16.9
18.8
19.1
23.8
28
36.6
44
54
63
74.5
91
108
132
153
178
189
230
253
284
316
358
433
473
536
609
663
734
819
890
1008
1114
1323
1556
1765
1773
1975
2125
2479
2751
2945

7.8
9.6
13.3
16.3
18
18.6
23
27.5
36
42
51
60
71.5
86
102
126
145
170
185
220
240
270
300
340
420
450
510
580
630
700
780
865
960
1060
1260
1483
1700
1710
1880
2050
2390
2620
2840

6.5
8
11
13.5
15
17.5
20
25
32
40
49
58
68.5
80
92
114
130
150
160
205
220
250
280
310
385
410
460
520
570
633
720
800
870
969
1145
1368
1540
1530
1690
1820
2150
2330
2550

6.3
7.8
10.6
13
14.4
15
18.4
22
28.8
34
40
48
58.5
68
81
101
116
136
148
176
193
216
240
273
336
360
408
464
504
560
624
693
768
848
1008
1186
1360
1368
1505
1640
1913
2096
2273

All machines have an auxiliary winding standard with 300% short circuit capability.

All machines have an auxiliary winding standard with 300% short circuit capability.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

12 | www.meccalte.com

Technical Guide: Ratings Book | 13

AVR Controlled Ratings 3ph 416-480v or 208-240v 60hz 1800rpm Broad Voltage

AVR Controlled Ratings 3ph 380v 60Hz 1800rpm

4 Pole | 60Hz | 3Phase

4 Pole | 60Hz | 3Phase

Voltage:

416-480/208-240 | Broad voltage

Voltage:

380 or 190 | Broad voltage

RPM:

1800

RPM:

1800

Insulation:

Class H

Insulation:

Class H

kVA @ Temp. Rise / Ambient C/ 0.8 PF

kVA @ Temp. Rise / Ambient C/ 0.8 PF

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

7.5
9.8
12.9
15
17.1
18.5
22.5
27.5
35
45
56
65
78.5
90
106
128
148
164
175
229
253
289
319
358
401
459
524
590
623
714
779
898
961
1115
1243
1585
1740
NA
1885
NA
NA
2635
NA

7.3
9.4
12.4
14.5
16.5
18
21.3
26.3
33.8
44
53
63
74.5
86
101
121
143
158
168
220
241
274
305
341
391
441
505
568
599
693
756
871
924
1071
1195
1524
1680
NA
1815
NA
NA
2540
NA

7
9
12
14
16
17.5
21
26
33
41
50
58
63.5
80
95
115
135
150
165
210
230
260
290
325
380
420
480
540
570
660
720
830
880
1020
1138
1451
1600
NA
1730
NA
NA
2420
NA

5.5
7.5
10
11.5
13
16.5
19
23.8
29
39
45
56
61.5
72
85
104
120
133
150
195
210
240
270
300
350
383
435
484
515
600
665
760
800
935
1090
1339
1450
NA
1570
NA
NA
2150
NA

5.6
7.3
9.6
11.3
12.5
14
16.8
21.3
26.3
33
38
46
53.8
64
76
93
108
120
132
168
184
208
233
260
304
336
384
433
456
528
576
664
704
816
910
1161
1280
NA
1385
NA
NA
1936

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

7
8.8
11.8
14.5
16
18
21.5
26.5
32
39
48
56
71
83
103
121
143
164
175
196
225
255
275
330
370
448
501
558
613
681
746
791
896
1038
1223
1443
1520
NA
NA
NA
NA
NA
NA

6.8
8.3
11.4
14
15.5
17.5
20.5
25.5
31
37
46
53
65.5
80
97
116
138
158
168
188
215
243
263
315
360
430
484
535
589
660
725
769
861
998
1176
1386
1470
NA
NA
NA
NA
NA
NA

6.5
8
11
13.5
15
17
20
25
30
35
42.5
50
63
75
93
110
130
150
160
180
205
230
250
300
350
410
460
510
560
630
690
733
820
950
1120
1320
1400
NA
NA
NA
NA
NA
NA

6
7.3
10
12.3
13.6
15.5
18.3
22.8
27.4
33
37
46
60
68
84
100
119
136
145
164
188
210
228
274
319
374
419
465
510
575
630
669
748
866
1021
1204
1280
NA
NA
NA
NA
NA
NA

5.3
6.4
8.8
10.8
12
13.6
16
20
24
28
34
40
52
60
74
88
104
120
128
144
164
184
200
240
280
328
368
408
448
504
553
586
656
760
896
1056
1120
NA
NA
NA
NA
NA
NA

NA

All machines have an auxiliary winding standard with 300% short circuit capability.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.
14 | www.meccalte.com

All machines have an auxiliary winding standard with 300% short circuit capability.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.
Consult factory for transient response performances as they may vary from the published data at this rating.
Technical Guide: Ratings Book | 15

AVR Controlled Ratings 3ph 380v dedicated 60Hz 1800rpm

AVR Controlled Ratings 3ph dedicated 600v 60Hz 1800rpm

4 Pole | 60Hz | 3Phase

4 Pole | 60Hz | 3Phase

Voltage:

380 | Dedicated

Voltage:

600 | Dedicated

RPM:

1800

RPM:

1800

Insulation:

Class H

Insulation:

Class H

kVA @ Temp. Rise / Ambient C/ 0.8 PF

kVA @ Temp. Rise / Ambient C/ 0.8 PF


MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

MODEL

WEIGHT (kg)

LEADS

AVR

163/27

150/40

125/40

105/40

80/40

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

8.4
10.5
14.3
17.5
19.3
21.6
25.8
31.8
38.4
47
57
67
83.5
100
114
139
171
196
209
240
264
300
330
396
444
525
589
655
721
804
883
NA
929
1148
1441
1704
NA
1944
2054
2159
2721
NA
2762

8
10
13.8
16.9
18.8
21
24.6
30.5
36.6
44
54
63
78.5
94
108
132
165
189
201
230
253
284
315
378
433
500
563
625
680
770
840
NA
892
1101
1380
1630
NA
1870
1958
2070
2608
NA
2646

7.8
9.6
13.3
16.3
18
20.4
24
30
36
42
51
60
75.5
90
102
126
156
180
192
220
240
270
300
360
420
480
540
600
660
744
816
NA
850
1050
1320
1560
NA
1800
1900
2000
2520
NA
2557

7.3
9
12
15
16.5
19
22
27.5
32
40
49
58
72.5
84
92
114
141
163
173
205
220
250
280
330
385
440
490
540
600
673
756
NA
770
959
1200
1440
NA
1620
1708
1778
2280
NA
2301

6.1
7.5
10.6
13
14.4
16.3
19.1
23.8
28.8
34
40
48
61
72
81
101
125
144
154
175
193
216
240
288
336
384
433
480
528
595
653
NA
680
840
1056
1248
NA
1440
1520
1600
2016
NA
2046

ECP3-1S/4
ECP3-2S/4
ECP3-1L/4
ECP3-2L/4
ECP3-3L/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4
ECO32-2S/4
ECO32-3S/4
ECO32-1L/4
ECO32-2L/4
ECO32-3L/4
ECP34-1S/4
ECP34-2S/4
ECP34-1L/4
ECP34-2L/4
ECP34-3L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-3SN/4
ECO38-1LN/4
ECO38-2LN/4
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-3S/4
ECO40-1L/4
ECO40-1.5L/4
ECO40-2L/4
ECO40-VL/4
ECO43-1SN/4
ECO43-2SN/4
ECO43-1LN/4
ECO43-2LN/4
ECO43-VLN/4
ECO46-1S/4
ECO46-1.5S/4
ECO46-2S/4
ECO46-1L/4
ECO46-1.5L/4
ECO46/2L/4

63
70
82
91.5
96
107
122
139
165
199
214
248
282
298
341
419
445
491
495
510
560
590
680
765
905
1040
1118
1171
1324
1380
1586
1693
1870
2090
2395
2660
2950
2770
3380
3440
3870
4260
4380

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1
DER1

8.4
10.5
14.3
17.5
19.3
21.6
25.8
31.8
37
47
57
67
83.5
100
114
139
171
196
209
240
264
300
330
396
444
525
589
655
721
804
883
NA
990
1215
1420
1700
1815
1944
2140
2333
2721
2980
3240

8
10
13.8
16.9
18.8
21
24.6
30.5
36.6
44
54
64
78.5
94
108
132
165
189
201
230
253
284
315
378
433
500
563
625
680
770
840
NA
940
1162
1355
1600
1740
1870
2040
2236
2608
2860
3105

7.8
9.6
13.3
16.3
18
20.4
24
30
36
42
51
60
75.5
90
102
126
156
180
192
220
240
270
300
360
420
480
540
600
660
744
816
NA
900
1115
1300
1550
1680
1800
1980
2160
2520
2760
3000

7.3
9
12
15
17
19
22
27.5
32
40
49
58
72.5
84
92
114
141
163
173
205
220
250
280
330
385
440
490
540
600
673
756
NA
825
1012
1170
1410
1520
1620
1780
1920
2280
2460
2700

6.1
7.5
10.6
13
14.4
16.3
19.1
23.8
28.8
34
40
48
61
72
81
101
125
144
154
175
193
216
240
288
336
384
433
480
528
595
653
NA
720
893
1040
1240
1345
1440
1584
1728
2016
2208
2400

All machines have an auxiliary winding standard with 300% short circuit capability.
These are special build machines. Check factory for delivery lead times.
Indicated voltage references to series or parallel star connection. Consult factory on connections available for ECO40,
ECO43 and ECO46.
16 | www.meccalte.com

All machines have an auxiliary winding standard with 300% short circuit capability.
ECO46: Refer To Factory before ordering to assure winding is available at 600 Volts at the indicated rating.
These are special build machines. Check factory for delivery lead times.
Indicated voltage references to series or parallel star connection. Consult factory on connections available for
ECO40, ECO43 and ECO46.
Technical Guide: Ratings Book | 17

AVR Controlled Ratings 1Ph Reconnected Winding 60Hz 1800rpm

AVR Controlled Ratings 1Ph Dedicated Winding 60Hz 1800rpm

4 Pole | 60Hz | 1Phase

4 Pole | 60Hz | 1Phase

Voltage:

240/230/220 120/115/110 - 277-138 | Reconnected

Voltage:

240/230/220 120/115/110 | Dedicated

RPM:

1800

RPM:

1800

Insulation:

Class H

Insulation:

Class H

220/230/240 Volts
kW @ 1.0 PF

220/230/240 Volts
kVA @ 0.8 PF

277 Volts
kW @ 1.0 PF

277 Volts
kVA @ 0.8 PF

220/230/240 Volts
kW @ 1.0 PF

220/230/240V
kVA @ 0.8 PF

MODEL

AVR

150/40

125/40

105/40

125/40

105/40

150/40

125/40

105/40

Eff%

125/40

105/40

Eff%

MODEL

AVR

150/40

125/40

105/40

Eff %

150/40

125/40

105/40

Eff %

ECP3-1S/4

DSR

4.6

4.5

4.1

4.1

3.8

5.4

5.3

4.9

76.9

4.8

4.4

74.9

ECP3-1S/4

DSR

6.1

5.6

76.9

5.6

5.5

5.1

74.9

ECP3-2S/4

DSR

5.9

5.7

5.3

5.2

6.8

6.6

6.2

79.1

5.6

77.1

ECP3-2S/4

DSR

7.7

7.5

7.1

79.1

6.7

6.5

77.1

ECP3-1L/4

DSR

7.9

7.7

6.9

6.3

9.3

8.2

80.7

7.3

78.7

ECP3-1L/4

DSR

10.3

10

9.2

80.7

9.3

8.3

78.7

ECP3-2L/4

DSR

9.6

9.3

8.6

8.3

11.1

10.8

10

81.2

9.6

79.2

ECP3-2L/4

DSR

12.4

12

11.1

81.2

11.2

10.8

10.1

79.2

ECP3-3L/4

DSR

10.5

10.2

9.3

9.2

8.4

12.3

12

11

81.5

10.8

10

79.5

ECP3-3L/4

DSR

13.9

14

12.5

81.5

12.4

12

11.2

79.5

ECP28-S/4

DSR

12.3

12.0

11

11

10

13.8

13.5

12.5

82.7

12.5

12

80.7

ECP28-S/4

DSR

15.4

15

13.9

82.7

13.9

13.5

13

80.7

ECP28-M/4

DSR

14.5

14

13

12

11

16.3

16

15

83.0

14.5

13.3

81.0

ECP28-M/4

DSR

17.3

17

15.9

83.0

16

16

14

81.0

ECP28-2L/4

DSR

17.6

17

15

15

14

20.3

20

18.3

83.7

18

16.5

81.7

ECP28-2L/4

DSR

22.3

22

20.4

83.7

19.3

19

17.4

81.7

ECP28-VL/4

DSR

20.1

19.5

18.1

17

15.8

23.7

23

20

84.2

20.5

18

82.2

ECP28-VL/4

DSR

25.7

25

22

84.2

22.6

22

20

82.2

ECO32-2S/4

DSR

25

24

23

22

20

29

28

27

84

25

24

82.3

ECO32-2S/4

DSR

37

36

34

84.3

32

31

29

82.3

ECO32-3S/4

DSR

29

27

26

25

23

34

32

31

85

29

28

82.8

ECO32-3S/4

DSR

41

40

36

84.8

35

34

31

82.8

ECO32-1L/4

DSR

36

34

33

31

30

42

40

38

87

36

35

84.7

ECO32-1L/4

DSR

47

46

41

86.7

42

41

37

84.7

ECO32-2L/4

DSR

42

40

38

36

34

50

48

46

87

43

41

85.3

ECO32-2L/4

DSR

52

50

45

87.3

47

46

40

85.3

ECO32-3L/4

DSR

52

49

46

45

41

63

60

56

87

54

49

85.3

ECO32-3L/4

DSR

57

55

52

87.3

52

50

47

85.3

ECP34-1S/4

DSR

60

58

55

53

50

72

70

66

87

64

60

84.7

ECP34-1S/4

DSR

80

78

73

86.7

73

71

67

84.7

ECP34-2S/4

DSR

63

61

56

55

51

76

74

67

88

67

61

85.8

ECP34-2S/4

DSR

85

82

75

87.8

77

74

68

85.8

ECP34-1L/4

DSR

73

71

64

63

58

88

86

77

89

77

70

86.9

ECP34-1L/4

DSR

98

95

86

88.9

88

85

78

86.9

ECP34-2L/4

DSR

85

82

74

73

64

102

99

89

90

88

78

87.9

ECP34-2L/4

DSR

113

110

99

89.9

101

98

86

87.9

ECP34-3L/4

DSR

86

84

76

75

66.4

104

101

91

90

90

80

87.9

ECP34-2L/4

DSR

NA

NA

NA

NA

NA

NA

ECO38-1SN/4

DSR

86

84

76

75

66

104

101

91

87

90

80

85.0

ECO38-1SN/4

DSR

NA

NA

NA

NA

NA

NA

ECO38-2SN/4

DSR

89

86

78

78

72

107

104

94

88

95

87

86.2

ECO38-2SN/4

DSR

119

115

105

88.2

109

105

96

86.2

ECO38-3SN/4

DSR

100

97

88

88

81

121

117

106

89

106

97

86.8

ECO38-3SN/4

DSR

134

130

118

88.8

121

118

108

86.8

ECO38-1LN/4

DSR

115

112

101

101

89

139

135

121

89

122

107

87.2

ECO38-1LN/4

DSR

154

150

135

89.2

139

135

119

87.2

ECO38-2LN/4

DSR

131

127

116

112

103

158

153

139

90

135

124

87.8

ECO38-2LN/4

DSR

175

170

155

89.8

154

150

137

87.8

ECO38-3LN/4

DSR

154

149

135

131

119.4

185

180

163

89

158

144

86.5

ECO38-3LN/4

DSR

206

200

181

88.5

180

175

160

86.5

ECO40-1S/4

DER1

198

187

172

176

164

239

225

207

89

212

198

86.5

ECO40-1S/4

DER1

265

250

230

88.5

250

235

220

86.5

ECO40-2S/4

DER1

224

209

194

202

179

270

252

234

89

243

216

86.6

ECO40-2S/4

DER1

300

280

260

88.6

285

270

240

86.6

*ECO40-3S/4

DER1

243

235

209

224

198

293

284

252

89

270

239

86.9

ECO40-3S/4

DER1

325

315

280

88.9

305

300

265

86.9

ECO40-1L/4

DER1

269

258

235

243

224

324

311

284

89

293

270

86.9

ECO40-1L/4

DER1

360

345

315

88.9

340

325

300

86.9

*ECO40-1.5L/4

DER1

303

291

261

273

247

365

351

315

89

329

297

87.2

ECO40-1.5L/4

DER1

405

390

350

89.2

380

365

330

87.2

ECO40-2L/4

DER1

332

321

299

299

276

401

387

360

89

360

333

87.3

ECO40-2L/4

DER1

445

430

400

89.3

415

400

370

87.3

*ECO40-VL/4

DER1

351

336

314

321

298.8

423

405

378

89

387

360

87.4

ECO40-VL/4

DER1

470

450

420

89.4

445

430

400

87.4

*120/115/110 V not available on these three Models.

All machines have an auxiliary winding standard with 300% short circuit capability.
Ratings measured with copper damper cage.

All machines have an auxiliary winding standard with 300% short circuit capability.
All the above machines are 12 lead. The Weights are the same as the standard 3 phase Models.
Zigzag, Delta, and Double Delta single phase connections available.
Consult Factory to choose for your application.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

18 | www.meccalte.com

Consult Factory to choose for your application.


Ratings measured with copper damper cage.
Indicated voltage references to series or paralle star connection. Consult factory on voltages available for ECO40,
ECO43 and ECO46 as for some machines the series/parallel connection may result in a different voltage output.

Technical Guide: Ratings Book | 19

Transformer Regulated Alternator Ratings

Alternators to fit Lister TS/TR

4 Pole | 50/60Hz | 1 & 3Phase

4 Pole | 50/60Hz | 1 & 3Phase

Voltage:

Various

Voltage:

Various

RPM:

3000/3600 1500/1800

RPM:

1500/1800

Insulation:

Class H

Insulation:

Class H

3Phase, 50Hz kVA @ 0.8 PF

4 Pole, 1500 RPM

400/230 Volts

380/190 Volts

kVA @ 0.8PF, 125/40 C Rise/Ambient

Lister Petter (TS & TR) 3Phase

50Hz, 1500RPM

60Hz, 1800RPM

MODEL

WEIGHT (kg)

LEADS

AVR

125/40

105/40

125/40

105/40

MODEL

WEIGHT (kg)

LEADS

AVR

380 415 Volts

480 Volts

440 Volts

416 Volts

CTP3-1S/4
CTP3-2S/4
CTP3-1L/4
CTP3-2L/4
ECSP28-S/4
ECSP28-M/4
ECSP28-2L/4
ECSP28-VL/4
ECSO32-2S/4
ECSO32-3S/4
ECSO32-1L/4
ECSO32-2L/4
ECSO32-3L/4

63
70
82
92
107
122
139
165
199
214
248
281
298

6
6
6
6
12
12
12
12
12
12
12
12
12

AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR

6.5
8
10
13
17
20
25
30
35
40
50
58
70

6.3
7.5
9
12
16
18.5
23
26
33
37
48
57
63

6.5
8
10
13
17
20
25
30
35
40
50
58
70

6.3
7.5
9
12
16
18.5
23
26
33
37
48
57
63

ECP28-1VS/4
ECP28-2VS/4
ECP28-OS/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4

98
101
104
107
122
139
165

12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR

7.8
11
13.5
17
20
25
30

9.4
13.3
16.25
19.3
24
30
36

8.9
12.1
15
18.6
23
27.5
36

8.1
11.4
13.8
17.5
21
26
33

3Phase, 60Hz kVA @ 0.8 PF

4 Pole, 1800 RPM

480/240 V

460/208 V

MODEL

WEIGHT (kg)

LEADS

AVR

125/40

105/40

125/40

105/40

CTP3-1S/4
CTP3-2S/4
CTP3-1L/4
CTP3-2L/4
ECSP28-S/4
ECSP28-M/4
ECSP28-2L/4
ECSP28-VL/4
ECSO32-2S/4
ECSO32-3S/4
ECSO32-1L/4
ECSO32-2L/4
ECSO32-3L/4

63
70
82
92
107
122
139
165
199
214
248
281
298

6
6
6
6
12
12
12
12
12
12
12
12
12

AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR

7.8
9.6
12
16
20.4
24
30
36
42
48
60
72
84

7
8.5
11
15
19
22
27.5
32
40
46
58
69
78

7.8
9.6
12
16
20.4
24
30
36
42
48
60
72
84

7
8.5
11
15
19
22
27.5
32
40
46
58
69
78

kVA @ 1.0PF, 125/40 C Rise/Ambient

Lister Petter (TS & TR) 1Phase

50Hz, 1500RPM

60Hz, 1800RPM

MODEL

WEIGHT (kg)

LEADS

AVR

110/220 Volts

120/240 Volts

ECP28-1VS/4
ECP28-2VS/4
ECP28-OS/4
ECP28-S/4
ECP28-M/4
ECP28-2L/4
ECP28-VL/4

98
101
104
107
122
139
165

12
12
12
12
12
12
12

DSR
DSR
DSR
DSR
DSR
DSR
DSR

5.0
7.0
8.5
11.5
13.5
16.5
19

6.3
8.8
10.8
13.5
16
20
23

Special mechanical modification allows the generator to be bolted directly to the engine without an adaptor.

3 Phase, kVA @ 0.8 PF

2 Pole, 3000 RPM 50Hz / 3600rpm 60Hz

400V 50Hz

480V 60Hz

MODEL

WEIGHT (kg)

LEADS

AVR

125/40

105/40

125/40

105/40

CTP3-1SN/2
CTP3-2SN/2
CTP3-3SN/2
CTP3-1LN/2
CTP3-2LN/2
ECSP28-M/2
ECSP28-2L/2
ECSP28-3L/2
ECSO31-2SN/2
ECSO31-3SN/2
ECSO31-1LN/2
ECSO31-2LN/2

51
57
63
72
78
129
136
141
178
204
216
235

6
6
6
6
6
12
12
12
12
12
12
12

AVIR
AVIR
AVIR
AVIR
AVIR
AVIR
AVIR

6.7
8.3
10.4
13.3
15.8
18.8
22.9
26
36
46
55
69

6
7.5
9.2
12.1
14.2
16.7
20.8
25
33
42
50
63

8
10
12.5
16
19
22.5
27.5
31.3
44
55
66
83

7.3
9
11
14.5
17
20
25
30
40
50
60
75

2 Pole, other voltages available. 2 & 4 Pole kW ratings available to 1000 kW. Refer to Factory.
CTO3 is Transformer, Brushless; ECSO is Transformer, Brushless with AVR control. Industrial or Irrigation.
AVIR regulator is available on option on the ECSO range.

20 | www.meccalte.com

Technical Guide: Ratings Book | 21

LT3 Lighting Tower Style 4 pole

NPE Alternator Range 4 Pole | Brushless AVR - Space saver

4 Pole | 50/60Hz | 1 Phase

4 Pole | 50/60Hz | 1 & 3Phase

Voltage:

Voltage:

Various

220/110; 240/120

RPM:

1500/1800

RPM:

1500/1800

Insulation:

Class H

Insulation:

Class H

3Phase

kW @ 220/110V, 50Hz, 1.0 pf

kVA 115/200-230/400V 50 Hz, 0.8pf

kVA 138/240-277/480V 60 Hz, 0.8pf

MODEL

WEIGHT (kg)

LENGTH (mm)

125/40

105/40

80/40

Eff %

MODEL

WEIGHT (kg)

LEADS

125/40

105/40

kVA

105/40

LT3-75/4

32

248

3.5

3.3

2.8

75.8

NPE 32-A/4

77

12

7.5

7.3

9.0

8.4

LT3-100/4

38

273

4.5

4.1

3.6

76.5

NPE 32-B/4

83

12

11.5

10.5

14.0

12.5

LT3-110/4

40

283

5.0

4.6

4.0

76.8

NPE 32-C/4

90

12

13.0

12.0

16.0

14.5

LT3-130/4

46

303

6.0

5.5

4.8

77.5

NPE 32-D/4

102

12

17.0

15.5

21.0

19.0

LT3-160/4

55

333

6.4

78.0

NPE 32-E/4

120

12

25.0

23.0

31.0

28.5

NPE 32-F/4

134

12

27.5

25.0

34

31

kW @ 240/120V, 60Hz, 1.0 pf


MODEL

WEIGHT (kg)

LENGTH (mm)

125/40

105/40

80/40

Eff %

1 Phase (Dedicated Winding)

LT3-75/4

32

248

4.5

4.1

3.6

76.5

MODEL

WEIGHT (kg)

LEADS

125/40

105/40

125/40

105/40

75

6.4

6.2

8.4

81

8.7

8.3

10.5

10

kW 115/230V 50 Hz

kW 120/240V 60 Hz

LT3-100/4

38

273

6.0

5.5

4.8

77.5

NPE 32-A/4

LT3-110/4

40

283

6.5

6.0

5.3

78.0

NPE 32-B/4

LT3-130/4

46

303

7.5

6.9

6.0

78.6

NPE 32-C/4

88

10.8

10.4

13

12.5

LT3-160/4

55

333

10

8.0

79.2

NPE 32-D/4

100

13.8

13.3

17

16

Brushless capacitor excited machines specifically for Metal Halide light tower lamps.
For custom voltages or non-standard lamp striking voltages, please refer to Factory.
2 Pole version of above generators available. Please refer to Factory.

NPE 32-E/4

118

18.5

17.5

22

21

NPE 32-F/4

132

22.5

21

26.5

25

1 Phase (Re-connected)

kW 115/230V 50 Hz

kW 120/240V 60 Hz

MODEL

WEIGHT (kg)

LEADS

125/40

125/40

NPE 32-A/4

75

12

NPE 32-B/4

81

12

7.5

9.3

NPE 32-C/4

88

12

8.6

10.6

NPE 32-D/4

100

12

11.3

14

NPE 32-E/4

118

12

16.6

20.6

NPE 32-F/4

132

12

18.3

22.6

Space Efficient- designed for length reduction.


All the generators on this page come standard with the SR7/2 AVR.

22 | www.meccalte.com

Technical Guide: Ratings Book | 23

NPE Alternator Range 2 Pole | Brushless AVR - Space saver

Totally Enclosed Alternators

2 Pole | 50/60Hz | 1 & 3Phase

4 Pole | 50/60Hz | 3Phase

Voltage:

Voltage:

Various

Various

RPM:

3000/3600

RPM:

1500/1800

Insulation:

Class H

Insulation:

Class H

3Phase

kVA 115/200-230/400V 50 Hz, 0.8pf

kVA 138/240-277/480V 60 Hz, 0.8pf

MODEL

WEIGHT (kg)

LEADS

125/40

105/40

kVA

105/40

NPE 31-A/2

77

12

8.0

7.8

10.0

9.3

NPE 31-B/2

83

12

10.5

9.6

13.0

11.6

NPE 31-C/2

90

12

13.5

12.3

16.5

15.0

NPE 31-D/2

102

12

21.0

19.2

25.2

23.0

NPE 31-E/2

120

12

26.0

23.8

31.5

29.0

NPE 31-F/2

134

12

32.0

28.8

38.4

35.0

1 Phase (Dedicated Winding)

kW 115/230V 50 Hz

kW 120/240V 60 Hz

MODEL

WEIGHT (kg)

LEADS

125/40

105/40

125/40

105/40

NPE 31-A/2

75

5.6

6.7

6.4

NPE 31-B/2

81

7.3

9.2

8.8

Railroad Duty Alternators


Mecc Alte has been building Railroad Duty alternators for
over two decades. Designed and manufactured to meet
harsh environmental demands for line haul locomotives
and switching applications.
Our rugged insulation system, with our unique,
overcoat of Butylh Rubber, provides unparalleled
mechanical strength and superior protection against
airborn rail dust, oil and grease.
Our TE (Totally Enclosed), pre-engineered generators
(some are listed below) are becoming the standard for
other harsh environmental applications, which include
gantry cranes for Asian Port Authorities and off-shore oil
platforms on two continents.

Typical Mechanical and Electrical Specification


Insulation System and mechanical reinforcement:
Stator treatments can include additional mechanical

bracing, additional lacing on the end turns; VPI


treatment, Butylh Rubber overcoat on the windings.
Rotor treatments can include VPI application(s),

closer machining tolerances on the rotor shaft with


shrink collars to prevent core pack movement.
Special Lead termination and configurations (long

leads, bus bars, etc.) as well as special cable glands,


cooling fans, adaptors and mounting reinforcement.

NPE 31-C/2

88

12.0

11

14.4

13.2

NPE 31-D/2

100

14

12.8

16.8

15.4

NPE 31-E/2

118

21.0

19

25.2

23

MODEL

WEIGHT (kg)

LEADS

AVR

125/40

105/40

80/40

95/50

NPE 31-F/2

132

25

23

30

27.5

TE34-1S/4

309

12

DSR

50

45

40

42

TE34-2S/4

375

12

DSR

60

54

48

50

TE34-1L/4

395

12

DSR

70

63

56

58

TE34-2L/4

429

12

DSR

80

72

64

67

1 Phase (Re-connected)

kW 115/230V 50 H

kW 120/240V 60 Hz

MODEL

WEIGHT (kg)

LEADS

125/40

125/40

NPE 31-A/2

75

12

5.3

6.6

kVA @ 50Hz Temp. Rise/Amb. C/ 0.8PF

NPE 31-B/2

81

12

8.6

NPE 31-C/2

88

12

11

MODEL

WEIGHT (kg)

LEADS

AVR

125/40

105/40

80/40

95/50

NPE 31-D/2

100

12

14

16.8

TE34-1S/4

309

12

DSR

60

54

48

50

NPE 31-E/2

118

12

17.3

21

TE34-2S/4

375

12

DSR

72

65

57.5

60

NPE 31-F/2

132

12

21.3

25.5

TE34-1L/4

395

12

DSR

84

76

67

70

TE34-2L/4

429

12

DSR

96

87

77

80

kVA @ 60Hz Temp. Rise/Amb. C/ 0.8PF

Space Efficient- designed for length reduction.


All the generators on this page come standard with the DSR AVR.

*Consult Factory for pricing.


Above generators are built to IP55 standards.
Custom engineered models are available to fit special applications. Consult Factory.

24 | www.meccalte.com

Technical Guide: Ratings Book | 25

Totally Enclosed alternators

2 Pole Industrial Ratings

14/20/24 Pole | 400Hz | 3Phase

2 Pole | 50/60Hz | 1 & 3Phase

Voltage:

115/200 208

Voltage:

Various

RPM:

3400/2400/2000

RPM:

3000/3600

Insulation:

Class H

Insulation:

Class H

Multi-Pole | 400Hz

kVA @ Temp. Rise / Ambient C

MODEL

WEIGHT (kg)

LEADS

AVR

RPM

125/40

105/40

HCO3-1S/14

48

12

UVR6/H

3428

5.5

HCO3-2S/14

54

12

UVR6/H

3428

6.5

HCO3-3S/14

63

12

UVR6/H

3428

8.5

HCO3-2L/14

70

12

UVR6/H

3428

10

10

HCO3-3L/14

79

12

UVR6/H

3428

13

12

HCO32-1S/20

186

12

UVR6/H

2400

45

40

HCO32-2S/20

220

12

UVR6/H

2400

50

45

HCO32-2L/20

274

12

UVR6/H

2400

60

55

HCO32-3L/20

299

12

UVR6/H

2400

70

65

HCP34-1S/20

304

12

UVR6/H

2400

75

70

HCP34-2S/20

344

12

UVR6/H

2400

95

85

HCP34-3S/20

379

12

UVR6/H

2400

125

115

HCP34-2L/20

429

12

UVR6/H

2400

150

135

HCP34-1SN/24*

304

12

UVR6/H

2000

60

55

HCP34-2SN/24*

379

12

UVR6/H

2000

90

80

HCP34-2LN/24*

429

12

UVR6/H

2000

125

110

HCO38-1L/24*

775

12

UVR6/H

2000

150

135

HCO38-2L/24*

837

12

UVR6/H

2000

180

165

HCO38-3L/24*

932

12

UVR6/H

2000

200

180

1 Phase - Reconnected

50Hz, 1.0 PF

60Hz, 1.0 PF

kW @ Temp Rise/Amb
110/120 Volts

kW @ Temp Rise/Amb
%EFF

MODEL

WEIGHT (kg)

AVR

125/40

105/40

ECP3-1S/2
ECP3-2S/2
ECP3-3S/2
ECP3-1L/2
ECP3-2L/2
ECP28-M/2
ECP28-2L/2
ECP28-3L/2
ECP28-VL/2
ECO31-2SN/2
ECO31-3SN/2
ECO31-1LN/2
ECO31-2LN/2
ECP34-1S/2
ECP34-2S/2
ECP34-1L/2
ECP34-2L/2
ECO37-1SN/2
ECO37-1LN/2
ECO37-2LN/2

51
57
63
72
78
129
136
141
156
178
204
216
235
343
412
455
491
508
676
762

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR

5.5
7
8
10
11.5
15
18
21
25.5
29
36
43
54
67
83
104
113
105
140
199

5
6.3
7.2
9
10.4
13
16
19
23
26
32
39
49
60
75
93
103
95
125
182

72.6
73.9
74.0
77.9
78.8
79.5
80.9
81.7
81.9
81.4
82.2
83.0
83.1
85.9
86.5
87.0
87.5
87.7
88.2
88.7

120/240 Volts

%EFF

125/40

105/40

6.6
8.4
9.6
12
13.8
17.5
21.5
25
30.5
35
43
52
65
80
100
125
139
125
209
302

5.9
7.6
8.6
10.8
12.4
16
19
23
27.8
32
39
47
59
72
90
113
125
112
141
156

74.2
75.6
75.7
79.8
80.7
81.1
82.5
83.3
83.5
82.8
84.8
85.5
85.6
88.1
88.4
89.0
89.7
89.7
90.3
91.0

* According BS 2G 219 - EN2292 - ISO 6858 - Mil Stnd 704F

3Phase

50Hz, 0.8 PF

60Hz, 0.8 PF

kVA @ Temp Rise/Amb


415/380 Volts

All machines have an auxiliary winding standard with 300% short circuit capability.
UVR6/H AVR has underfrequency, over voltage protection, 3ph reference; regulation is +/- 1%
Line Drop Compensator is also available as an option.
Custom projects available for dedicated power nodes

The following accessories are available upon request for an additional charge:
Space Heaters
Temperature detectors (thermistors or PT100) for stator windings and bearings.
IP45 or IP54 rated enclosure.
Paralleling CTs for parallel operation.
Black Butylh Rubber overcoat for superior winding protection in hazardous environments as option.
Remote voltage control.

2/3 pitch windings with skewed slots for maximum reduction of harmonic content.
4 layers of polyester in addition to a clear varnish and EG43 overcoat on the main and exciter windings is standard
on 400 Hz machines.

MODEL

WEIGHT (kg)

AVR

125/40

105/40

ECP3-1S/2
ECP3-2S/2
ECP3-3S/2
ECP3-1L/2
ECP3-2L/2
ECP28-M/2
ECP28-2L/2
ECP28-3L/2
ECP28-VL/2
ECO31-2SN/2
ECO31-3SN/2
ECO31-1LN/2
ECO31-2LN/2
ECP34-1S/2
ECP34-2S/2
ECP34-1L/2
ECP34-2L/2
ECO37-1SN/2
ECO37-1LN/2
ECO37-2LN/2

51
57
63
72
78
129
136
141
156
178
204
216
235
343
412
455
491
508
676
762

DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR
DSR

8.0
10.0
12.5
16.0
19.0
22
27
31.5
40
44
55
66
83
100
125
156
170
158
210
300

7.3
9.0
11.0
14.5
17.0
20.0
25.0
30.0
37.0
40.0
50.0
60.0
75.0
90.0
112.5
140.0
153.8
141.8
188.2
271.3

%EFF

78.5
80.5
83.0
84.5
85.8
85.2
86.4
87.2
87.8
87.4
88.1
88.4
89.0
89.7
90.4
90.9
91.5
91.7
92.2
92.8

kVA @ Temp Rise/Amb


480/440 Volts

416/208 Volts

125/40

105/40

125/40

105/40

9.6
12.0
15.0
19.3
22.8
26.5
32.5
38
48
53
66
80
99
120
150
188
208
188
313
360

8.6
10.8
13.0
16.8
20.5
24.0
30.0
36.0
44.0
47.5
60.0
72.5
90.0
107.5
135.0
168.8
187.5
169
211
234

8.3
10.4
12.9
16.5
19.6
23
28
33
45
45
58
69
85
105
130
160
175
163
200
219

7.4
9.3
11.1
14.4
17.6
20.0
26.3
31.3
41.5
41.3
51.3
62.5
77.5
95.0
120.0
145.0
160.0
150
181
200

%EFF

79.9
82.8
84.5
86.1
87.2
86.2
87.9
89.2
89.7
89.2
89.5
90.2
90.5
91.8
92.2
92.8
93.5
94
94
95

*Refer To Factory for pricing. Larger 1 or 3 Phase ratings up to 3 MW are available. Please Consult Factory.

26 | www.meccalte.com

Technical Guide: Ratings Book | 27

2 Pole Portable Ratings Single Phase

2 Pole Portable Ratings Three Phase

2 Pole | 50/60Hz | 1Phase

2 Pole | 50/60Hz | 3Phase

Voltage:

Various

Voltage:

Various

RPM:

3000/3600

RPM:

3000/3600

Insulation:

Class H

Insulation:

Class H

2 Pole | 1Phase (Capacitor)

kW @ 1.0 PF, 50Hz

kW @ 1.0 PF, 60Hz

2 Pole | 3Phase (Transformer)

kVA @ 0.8 PF, 50Hz

kVA @ 0.8 PF, 60Hz

MODEL

WEIGHT (kg)

115/230

%EFF

120/240

%EFF

MODEL

WEIGHT (kg)

230/400

%EFF

277/480

%EFF

S15W-45

8.2

1.2

68.7

1.5

69.7

T16F-130

30.5

6.0

79.8

7.2

80.3

S15W-60

10.4

1.8

70.2

2.2

71.2

T16F-160

34.5

7.5

82.0

9.0

82.5

S15W-75

12.2

2.1

71.4

2.5

71.8

T20FS-130

44.7

10.0

81.5

12.0

83.0

S15W-85

13.2

2.4

71.8

2.9

72.2

T20FS-160

51.7

12.5

82.0

15.0

83.5

S15W-102

15.0

2.8

72

3.4

72.3

T20F-200

59.5

15.0

82.6

18.0

83.8

S16W-75

14.1

2.5

74

74.6

BTP3-1L

69.0

16.0

83.0

19.2

84.5

S16W-90

15.9

3.5

75

4.2

75.6

BTP3-2L

76.0

20.0

84.0

24.0

86.4

S16W-105

17.7

4.1

76

4.9

76.6

S16W-130

20.9

77

77.6

S16W-150

23.6

5.7

78

6.8

78.6

S20W-95

27.2

77.5

7.2

78.2

S20W-110

30.4

78.4

8.4

79.2

S20W-130

34.9

8.5

79

10.2

79.8

S16F-150

28.1

5.5

79

6.6

79.6

S16F-180

30.8

6.5

79.5

7.8

80.1

S20FS-130

41.7

8.5

79

10.5

79.4

S20FS-160

48.5

10.0

79.2

12.0

79.6

S20F-200

56.2

12.0

80.3

14.4

80.8

S20F-230

59.9

13.0

82.1

15.5

82.7

Above machines are brush type with transformer control.

2 Pole | 3Phase (AVR)

kVA @ 0.8 PF, 50Hz

kVA @ 0.8 PF, 60Hz

MODEL

WEIGHT (kg)

230/400

%EFF

277/480

%EFF

ET16F-130

30.0

5.5

80.2

6.6

80.6

ET16F-160

34.0

6.5

82.3

7.8

82.5

ET20FS-130

44.2

9.0

81.9

11.0

83.6

ET20FS-160

51.2

11.5

82.4

14.0

83.9

ET20F-200

59.0

13.5

82.9

16.5

84.1

Above machines are brush type with AVR control.

Above machines are brushless with capacitor control and optional AVR.

2 Pole | 1Phase (AVR)

kW @ 1.0 PF, 50Hz

MODEL

WEIGHT (kg)

115/230

%EFF

120/240

%EFF

ES16F-130

29.0

4.5

79.4

5.5

80

ES16F-160

31.8

5.5

79.8

6.8

80.5

ES20FS-130

43.1

8.0

79.4

9.6

79.8

ES20FS-160

49.9

9.5

79.5

11.4

80

ES20FS-200

58.1

11.0

80.7

13.2

81.2

kW @ 1.0 PF, 60Hz

Above machines are brush type with AVR control.

28 | www.meccalte.com

Technical Guide: Ratings Book | 29

Wiring Connection Diagram

Wiring Connection Diagram

50Hz Connections

60Hz Connections

The following are the most common connection arrangements utilized with Mecc Alte generators. Always verify that
the connections of all the leads from the main stator are consistent with the nameplate voltage required. Connection
diagrams are supplied with every generator and should be used as the primary source of information. Please consult
the factory for any questions regarding these connections.

The following are the most common connection arrangements utilized with Mecc Alte generators. Always verify that
the connections of all the leads from the main stator are consistent with the nameplate voltage required. Connection
diagrams are supplied with every generator and should be used as the primary source of information. Please consult
the factory for any questions regarding these connections.

L1

SERIE STELLA
SERIES STAR

L1

1
2
3

7 6
5

1011

23

67

R
L1

S
L2

T
L3

2 4

L2
L1L2L3: 200V 3
L1L2: 200V
L1L3: 200V
L2L3: 200V
NL1: 115V
NL2: 115V
NL3: 115V

4812

7
24

68

13

57

911

R
L1

S
L2

T
L3

10
12

DOPPIO TRIANGOLO
DOUBLE DELTA

1
3

11

1012

L1L2L3: 115V 3
L1L2: 115V
L1L3: 115V
L2L3: 115V

7
5

24

5 7

9 11

S
L2

T
L3

50Hz

Parallel Delta
Zig-Zag
Single Phase
Parallel Zig-Zag
Single Phase
Double Delta

11

L2

L2

12
4

811

L1L2: 230V
NL1: 115V
NL2: 115V

L1L2L3: 480V 3
L1L2: 480V
L1L3: 480V
L2L3: 400V
NL1: 277V
NL2: 277V
NL3: 277V

67

112

24
54

98

R
L1

S
L2

T
L3

L-L
L-N
L-L
L-N
L-L
L-N
L-L
L-L
L-N
L-L
L-N
L-L
L-N

23

5
2

1 PHASE ZIG-ZAG

5 12

7 4

T
L2

12

1012

L1L2: 230V
NL1: 115V
NL2: 115V
N

24

1 3

5 7

R
L1

S
L2

1
4

67

R
L1

S
L2

T
L3

L1

1012

Series 40 (3S, 1.5L, VL), 43, 46

800
460
400
231
460
230
230
690
400
460
230
460
230

830
480
415
240
480
240
240
720
415
480
240
480
240

24

68

13

57

911

R
L1

S
L2

T
L3

7
5

24

9 11

T
L3

Single Phase
Parallel Zig-Zag
Single Phase
Double Delta

11

L2

12
4

811

L1L2: 240V
NL1: 120V
NL2: 120V

1011

23

67

112

54

98

R
L1

S
L2

T
L3

1 PHASE ZIG-ZAG

L-L
L-N
L-L
L-N
L-L
L-N
L-L
L-L
L-N
L-L
L-N
L-L
L-N

23

5 12

7 4

S
L2

12

10
2

L1L2: 240V
NL1: 120V
NL2: 120V
N

1012

24

68

1 3

5 7

9 11

R
L1

S
L2

120/240 VOLT. 1PHASE

Series 40 (3S, 1.5L, VL), 43, 46

415
240
208
120
240
120
120
359
207
240
120
240
120

830
440
415
240
440
220
220
720
415
440
220
440
220

460
266
230
133
266
133
133
400
230
266
133
266
133

480
277
240
139
277
139
139
415
240
277
139
277
139

L1

120/240 VOLT. 1PHASE

Series 3, 28, 31, 32, 34, 38, 40 (1S, 2S, 1L, 2L)

440
254
220
127
254
127
127
380
220
254
127
254
127

1
4

69

R
L1

L2

9
6 11

880
460
440
254
460
230
230
760
440
460
230
460
230

920
480
460
266
480
240
240
800
460
480
240
480
240

In case of single phase load, it is important that the phase current does not exceed the nominal value.

In case of single phase load, it is important that the phase current does not exceed the nominal value.

In three phase zig-zag connection the rated power must be multiplied by 0.866.

In three phase zig-zag connection the rated power must be multiplied by 0.866.

30 | www.meccalte.com

240 VOLT. 3PHASE


120/240 VOLT. 1PHASE

10

5
2

1 10

120 VOLT. 3PHASE


120 VOLT. 1PHASE (L1-L2)

Parallel Delta
Zig-Zag

L1L2L3: 240V 3
L1L2: 240V
L1L3: 240V
L2L3: 240V
NL1: 120V
NL2: 120V

4
8

68

S
L2

Series Delta

L2

5 7

Parallel Star

208 VOLT. 3PHASE


120 VOLT. 1PHASE

DOPPIO TRIANGOLO
DOUBLE DELTA

R
L1

Series Star

60Hz

880
508
440
254
508
254
254
760
440
508
254
508
254

1012

1
3

1 3

115/230 VOLT. 1PHASE

760
440
380
219
440
220
220
660
380
440
220
440
220

L1L2L3: 208V 3
L1L2: 208V
L1L3: 208V
L2L3: 208V
NL1: 120V
NL2: 120V
NL3: 120V

4812

10 8

11
9

L3

11

L1
10
12

L3
L1L2L3: 125V 3
L1L2: 120V
L1L3: 120V
L2L3: 120V

9 11

L2

10

480 VOLT. 3PHASE

68

380
220
190
110
220
110
110
330
191
220
110
220
110

440
254
220
127
254
127
127
380
220
254
127
254
127

23

11
2

Series 3, 28, 31, 32, 34, 38, 40 (1S, 2S, 1L, 2L)

415
240
208
120
240
120
120
360
208
240
120
240
120

1011

10

115/230 VOLT. 1PHASE

400
230
200
115
230
115
115
346
200
230
115
230
115

PARALLELO TRIANGOLO
PARALLEL DELTA

9
6 11

L2

L1

69

R
L1

7 6

L3

L2

2 4

12

SERIE TRIANGLO
SERIES DELTA

1 3

12

230 VOLT. 3PHASE


115/230 VOLT. 1PHASE

10

1 10

115 VOLT. 3PHASE


115 VOLT. 1PHASE (L1-L2)

Series Delta

1011

68

R
L1

Parallel Star

L1L2L3: 230V 3
L1L2: 230V
L1L3: 230V
L2L3: 230V
NL1: 115V
NL2: 115V

PARALLELO STELLA
PARALLEL STAR

4
12

1011

4
8

L3

1 3

Series Star

L2

L3

L1

1
2
3

L1

PARALLELO TRIANGOLO
PARALLEL DELTA
9

11

SERIE STELLA
SERIES STAR

200 VOLT. 3PHASE


115 VOLT. 1PHASE

400 VOLT. 3PHASE

1012

L1

L1

10

10 8

11
9

L3

12

SERIE TRIANGLO
SERIES DELTA

1 3

12

L3
L1L2L3: 400V 3
L1L2: 400V
L1L3: 400V
L2L3: 400V
NL1: 230V
NL2: 230V
NL3: 230V

4
12

1011

PARALLELO STELLA
PARALLEL STAR

960
554
480
277
554
277
277
830
480
554
277
554
277

Technical Guide: Ratings Book | 31

SAE Coupling and Mounting Guide

Environmental Considerations

SAE Flywheel Housing Dimensions

Altitude Derations/Environmental

Mounting Arrangements.

Temperature
& Altitude
Voltage: 0000000
Environmentla
Concerns
RPM:
0000000
Humidity
& Moisture
Insulation:
Class X

Temperature and Altitude

S. A. E. Flywheel Housing Dimensions (in)


SAE No.

Holes

Size

00
0
1/2
1
2
3
4
5
6

31
25.5
23
20 1/8
17 5/8
16 1/8
14.25
12 3/8
10.5

33.5
26.75
24 3/8
20 7/8
18 3/8
16 7/8
15
13 1/8
11.25

34.75
28
25.5
21.75
19.25
17.75
15 7/8
14
12 1/8

16
16
12
12
12
12
12
8
8

1/2-13
1/2-13
1/2-13
7/16-14
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16

XG

Holes

Size

21
18
16
14
11 1/2
10
8
7 1/2
6 1/2
17.75 D
15.50 D
12.75 D

23
19 5/8
18 1/8
16 1/8
12.375
10 7/8
8 7/8
8 1/8
7.25
----

25.25
21 3/8
19 1/4
17.25
13.125
11 5/8
9 5/8
8.75
7 7/8
15.5
13 7/8
11

26.5
22.5
20 3/8
18 3/8
13 7/8
12 3/8
10 3/8
9 1/2
8 1/2
17.75
15.50
12.75

0
5/8
5/8
1
1 9/16
2 1/8
2 7/16
1 3/16
1 3/16
.72
.72
0

12
6
8
8
8
8
6
8
6
8
8
4

5/8-11
5/8-11
1/2-13
1/2-13
3/8-16
3/8-16
3/8-16
5/16-18
5/16-18
5/8-11
5/8-11
1/2-13

Generators are often exposed to harmful airborne


pollutants, like sand and saltwater which may require
some form of protection to reduce or eliminate these
harmful agents. Common elements like dirt, gravel or
rock dust can create abrasive and potentially damaging
effects on the windings of the generator. While the
addition of filters, baffles, or housings will certainly help
extend the life of the protective insulation, it may be
equally effective to overcoat the windings at point of
manufacture. It is also extremely important to recognize
that filters and other devices can affect the airflow
through the generator and create additional heat in the
windings. It is also important to understand that the use
of filters requires a strict maintenance regime.

Coupling

6.5
7.5
6.5
7.5
8
6.5
7.5
8
10
11.5
8
10
11.5
10
11.5
11.5
14
17.75 D
14
18
17.75 D
14
18
18
21
24

2
1

1/2

0
00

32 | www.meccalte.com

ECO3

Mecc Alte has a variety of insulation treatments which


can add years of life to your generator, and ensure
that the windings are protected in these harmful
environmental applications. Please refer to our separate
Technical guide: Insulation Protection Systems for
further guidance on our; standard, standard +, grey,
total and total + systems. Please note on some specific
models a slight power de-rate is considered when the
total systems are applied.
Please consult your Mecc Alte Representative for
application reviews and recommendations.

Humidity and Moisture

Available Mounting Arrangements


Adaptor

Environmental Concerns

SAE Flywheel Dimensions (in)


Flywheel

Higher altitudes also require a derate, specifically when


it exceeds 3300 ft., or 1000 Meters. Again, please refer
to the Altitude Deration Chart below to determine the
necessary derate.

Temperature and altitude individually or combined, have


an effect on the generator power available. Temperature
may be considered as both the air inlet to the generator
and also the ambient air around the generator. When the
ambient air or air entering the generator exceeds 40C,
or 104 F, it becomes necessary to derate the output of
the generator. The chart below gives the recommended
amount to adjust for the higher temperatures.

ECO28

ECO32

ECP34

ECO38

ECO40

ECO43

ECO46

NPE 32

and operating conditions with proper ventilation are


both important considerations when determining what
protection is required. Once again, please consult your
Mecc Alte Representative for assistance in selecting
proper protection and modifications.

Another common enemy of the insulation system is


high humidity, salt air and moisture. While the windings
are certainly protected against these conditions, space
heaters can be added insurance to promote long life
and trouble free operation. The location of the unit

Altitude & Ambient Temperature Deration Coefficients


Ambient Temperature (0C)
Altitude (meters)

25

40

45

50

55

60

< 1000

1.07

.96

.93

.91

.89

1000 1500

1.01

.96

.92

.89

.87

.84

1500 2000

.96

.91

.87

.84

.83

.79

2000 3000

.90

.85

.81

.78

.76

.73

Technical Guide: Ratings Book | 33