Argentina. Tel +54 11 4502-3535 Fax +54 11 4502-7040 Tormene Americana DDI S.A. presents their new 8 Input Digital Module. To use with any PLC or RTU and every application. It is used to isolate the DI Input module of your PLC or RTU from field devices. Offers per-channel surge and transient discharge, fuse based protection and cut blade terminal block. Offered in metal housings, these proximity sensors are interchangeable with existing sensors of similar characteristics or can be designed specifically for individual application needs. Model TADDI -8-DI Exclusive Distributor: Tormene Americana DDI A member of the Tormene Americana Group DIGITAL INPUT CIRCUITRY The digital input circuitry has a relay protection for the digital inputs. The relay has the function to isolate the field connections from the cabinet equipments or PLCs digital input boards. This relay isolation is provided for each channel plus a green led indicator of input active. There are three configuration jumpers per channel to make the digital input powered or not. It is very important in using active or passive indicators bringing a great design versatility. It is useful with sensors that drives different voltages, the board can be customized at factory for each application. Contact: E-Mail: info@ddei.com.ar Website: www.ddei.com.ar
CHANNEL PROTECTION The digital output protection circuitry includes a fast acting fuse with a red led indication of fuse blowed. The field terminal block contains a cut blade per input and per channel. This characteristic is very useful at field to isolate a individual channel without the need of disconnection of any cable. An digital ground connection input is provided per channel. 8 Digital Input Module FEATURES These TADDI-8 I/O protection modules provides an integral solution in connectivity and protection of digital input signals from field. They have an built-on field terminal block (FTB) with cut blades and ground connection for each input. These FTBs eliminates the use of external terminals to connect field elements to the controllers or PLCs. So, the use of these modules saves costs and space in complex cabinets. On the other side, they have a pin type connector with a bus line cable to route the protected fields elements to controllers terminal screws. In this way, the cable routing is more reliable and simple with the add of save time and costs. SPECIFICATIONS Mounting: Standard 35 mm. DIN Rail. Dimensions: 147mm. x 110 mm. x 60mm. Fuse Protection: BUSSMAN type 250 mA. 250 VAC Fast acting per channel. With fuse holder on board. Electrical Loop: Configurable via set jumpers powered or not per channel. Supported Digital Signal Types: Dry contacts or voltage powered. Input Voltage Ratings: 0-200 VDC @ 1 A. Surge Protection: First Stage: Continuos voltage breakdown 100 V. peak breakdown voltage 500 V(1kv/s) current discharge pulse 2.5 KA. - Second Stage: Clamping voltage 92 v energy 1.8 joules current 250 A.- Third Stage: Clamping 33.2 V @ 40 A (For 24 V. supply) voltage breakdown 27 V @ 1A (For 24 V Supply). Fuse Blow Indication: Per channel 3 mm. on board red led. Field Terminal Block: Cable size AWG 24-12 - max. current 15 A max Voltage 320 V. Operating Temperature: -40 to 70 degrees Celsius. 40 to 158 degrees Fahrenheit. Weight: 468 Grs. - 1.03 Lb. MOUNTING The board is provided to mount directly on a industrial standard DIN rail, easy to accommodate in cabinets or industrial equipments. CONNECTIONS A 24 points terminal input block with individual cut blades is provided for field instrumentation connection labeled TB1.A dedicated point for digital ground conection is included per channel without cut blade. They are numbered on the overlay of the board per each channel input. A 3 points terminal input block is used to power up the board (TB4) and a power ground connection is provided too. The output connection is a 10 pin in line connector(TB2 & TB3),TB2 is the common relay outputs and TB3 is the normal open outputs. SURGE PROTECTION Surge protection circuitry is built-in provided with three step protection technology. The TADDI-8 has an individual surge protection circuitry for each channel. This technology is based in a three stage level of protection. The first step is a fast gas discharger, intended basically for lightning discharges. The second stage is a sensitive varistor type discharger, especially indicated for surge line protections. The last stage is a MOV type discharger, it provides protection against undesirables voltage levels. The component values for each model are provided according to the application to be implemented. The surge protection modules are mounted on I/O boards with solded terminals for easy replace and repair after a surge event. This eliminates the need of replace the entire board.
Approval Standard For Intrinsically Safe Apparatus and Associated Apparatus For Use in Class I, II, and III, Division 1, Hazardous (Classified) Locations