POWER CIRCUIT BREAKER


DL 2108T02
DL 2108T02
ver b20130115
1
DL 2108T02 POWER CIRCUIT BREAKER


Three-phase power circuit breaker with normally closed auxiliary contact.


DL 2108T02
ver b20130115
2
1. TECHNICAL VALUES

1.1 Power circuit

Insulation voltage: 750V.
Thermal current: 20A
Permitted power at AC3 load:


Single-phase Three-phase
115 230 230 400 500 690 V
0.37 0.75 1.5 2.2 3 3 kW


1.2 Auxiliary contact

Insulation voltage: 750V.
Rated current: 3A


1.3 Auxiliary power

Single-phase voltage 220V, 50-60Hz





2. DRIVING AND SIGNALLING CIRCUITS

The power breaker switch can be controlled manually using the push-buttons onand off or
externally via the switching contact PLC or RELAY.

This power contacts state is indicated by leds:
Green led = open contacts.
Red led = closed contacts.

While at SIGNAL OUTPUT terminals is available a TTL level:
Low level ( 0V )= open contacts.
High level ( 5V )= closed contacts.

The RS flip-flop state is indicated by a led:
Yellow led = set flip-flop.



DL 2108T02
ver b20130115
3
3. PUSH-BUTTON CONTROL

The PLC and RELAY control inputs must be low (short - circuit).



DL 2108T02
ver b20130115
4
When the module is supplied with the auxiliary voltage, the power breaker K is normally open.


Pressing the push-button S on the RS flip-flop is set and the power breaker K is closed.

At SIGNAL OUTPUT terminals is present a high level, TTL compatible.

Pressing the push-button S off the RS flip-flop is reset and the power breaker driving is inhibited.







DL 2108T02
ver b20130115
5
4. RELAY CONTROL

The PLC control input must be low (short-circuit).

The RELAY control input is connected to a switching contact, normally closed.


DL 2108T02
ver b20130115
6
When the module is supplied with the auxiliary voltage, the power breaker K is normally open.




With closed RELAY contact, pressing the push-button S on the RS flip-flop is set and the power
breaker K is closed.

When the RELAY contact is open the RS flip-flop is reset and the power breaker driving is
inhibited.

Only when the RELAY contact is closed again it is possible to drive the power breaker K by means
of the push-button S on.












DL 2108T02
ver b20130115
7
5. PLC CONTROL

The RELAY control input must be low (short-circuit).

The PLC control input is connected to a switching contact, normally closed.


DL 2108T02
ver b20130115
8
When the module is supplied with the auxiliary voltage the power breaker K is normally open.



With closed PLC contact, pressing the push-button S on the RS flip-flop is set and the power
breaker K is closed.

When the PLC contact is open the drive coil of the power breaker is inhibited and the power contact
K is open. The RS flip-flop remains in set state and when the PLC contact is closed again the power
breaker K is closed.

Only pressing the push-button S off the RS flip-flop is reset and the power breaker driving is
inhibited.




1996 - 2013 DE LORENZO SPA - Printed in Italy - All right reserved