WallMaterial:

Compressivestrengthofwall 2 N/mm
2
Allowablecompressivestressofwall 0.67 N/mm
2
Allowabletensilestressofwall 0 N/mm
2
GradeofSteel 415 N/mm
2
Allowabletensilestressofrebar 230 N/mm
2
Allowableshearstressofrebars 230 N/mm
2
Widthofwall 230 mm
Thicknessofmicroconcreting 50 mm
MinimumExpectedshearstrengthofmasonry 0.01 N/mm
2
INPLANERESPONSEOFWALLSSPARALLELTOXAXIS
EnvelopeofmaximumverticalStresses,S22(N/mm
2
)
LoadCase: EnvelopX
Wall2 (WallinXdirection)
Maximumtensilestress 0.275 N/mm
2
Lengthoftensilestresszone 400 mm
Averagetensilestress 0.1375 N/mm
2
Totaltensileforce 12650 N
Areaofverticalsteelrequired 55.00 mm
2
Diameterofreinforcedused 4.75 mm
Areaofonerebar 17.72 mm
2
Numberofrebars 3 nos
Numbersofrebarsineachdirection 2 nos
Widthofverticalband 200 mm
Spacingofbars 200 mm
Provide200mmwideverticalbandatbothsideswith4.75mmdiabar@200mmc/c,fy415.
Wall3 (WallinXdirection)
Maximumtensilestress 0.289 N/mm