You are on page 1of 3

Page 1 of 3

Fanuc 11 M
NCnet 7.0 settings

Set these parameters on the machine

Parameter No. Value Parameter No. Value
5001 1 5120 4
5002 2 5121 2
5003 3 5122 9
5110 4 5130 4
5111 2 5131 2
5112 9 5132 9

Setting data

TV CHECK = 0 (0:Off; 1:On)
Punch code = 0 (0:ISO; 1:EIA)
Input device = 1 (1 ~3:RS232C; 10:RMFBUF; 13:RS422)
Output device = 1 (1 ~3:RS232C; 10:RMFBUF; 13:RS422)

To set the controller in the Drip feed mode

Set the Tape mode on.

Note: The Dripfeed (Blockwise) program transfer works only when the dripfeed facility is
enabled on the machine controller.
Parameters for the various baud rates

For baud rates other than 2400 set the parameter 5112, 5122, 5132 as follows

Baud rate Parameter
50
100
110
150
200
300
600
1200
2400
4800
9600
1
2
3
4
5
6
7
8
9
10
11









Page 2 of 3
Set the following parameters on the PC

Machine details

Machine name MCH-1
Control system Fanuc
Machine ID 01
Communication Channel Serial Port
Port Number Any free COM port
Folder for PC to Machine transfer Transmit directory
Folder for Machine to PC transfer Receive directory
Baud rate 2400
Data bits 7
Parity Even
Stop bits 2
Handshake Hardware



General settings
Ignore this. Leave all data as it is.

Transmit settings

Wait period at start of transmission 10.00
Wait period after transmitting program 5.0
Size of transmit packet 0
Delay period after each packet 0
Wait for XON before transmitting program No
Transmit comments? Yes
Comment start character (
Comment end character )
Translation mode for CR Transmit as CR
Translation mode for LF Transmit as LF
Acknowledgement and error (Mode of transmission) Transmit descriptive message
ACK/ERR Message start text %
O1234
ACK/ERR Message start text M30
%
Filter Null Character Yes



NC Program settings

Program start string
Program end string
Characters to transmit at start 0 Number of Characters 0
Characters to transmit at start 0 Number of Characters 0

Receive settings

Wait period before receiving program 45.0
Wait period after receiving program 5.0
Transmit XON before transmitting program No
Auto compare and save Yes
Acknowledgements and errors Transmit descriptive messages
Translation mode for CR Ignore

Page 3 of 3
Translation mode for LF Save as CRLF
Ignore control characters other than CR-LF Yes
Save Program between Start Characters and End Characters No
Start Program reception after these characters are received
End Program reception after these characters are received

To set the PC in the Drip feed mode

Set Handshake to =Software
Set Drip feed =ON






Cable connections

If the PC has 9 pin connector

Null modem Full Handshake
PC
9 pin
1
2
3
4
5
6
7
8
8
2
3
20
7
6
4
5
CNC
25 pin

PC
9 pin
1
2
3
4
5
6
7
8
8
2
3
6
7
20
5
4
CNC
25 pin


If the PC has 25 pin connector


Null modem Full Handshake
PC
25 pin
8
2
3
20
7
6
4
5
8
3
2
20
7
6
4
5
CNC
25 pin

PC
25 pin
8
2
3
20
7
6
4
5
8
3
2
6
7
20
5
4
CNC
25 pin

You might also like