Operating the easYgen-3200


* Brief Information *
Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and


NOTE
This is only a brief operator information. Refer to the respective manuals for detailed information
about installation, configuration and operation of the unit.
Visit www.woodward.com/power/easygen-3000 to download all manuals.

3
1
2
3
4
13 9 10 11 14
5
6
7
8
12

The Stop button is ALWAYS active and stops the
engine when pressed. *
1

2

3

5

6

7

8

9

10

11

The push buttons on the front panel are assigned to
softkeys on the display. Each softkey is assigned to
a function depending on the mode of operation.
12


The LC display contains softkey characters,
measuring values, operating modes, and alarms.
13

14

The left LED indicates that the unit is in STOP
mode. The right LED indicates that alarm
messages are active / present in the control unit.

Alarms


Acknowledge horn
Softkey
8

Alarms may only be acknowledged if they are not active anymore, i.e. their
cause has been removed.
The easYgen stores a list with all active alarms, which may be read out by
the service personnel. The symbol indicates that an alarm condition is
still present.
Display alarm list
Softkey
5


Acknowledge alarm in list
Softkey
8


Operating Modes


AUTOMATIC operating mode
Softkey
2

The operating mode is selected by pressing the , or softkeys. The
active operation mode is displayed in the lower left corner:
The symbol indicates that AUTOMATIC operating mode is enabled.
The symbol indicates that MANUAL operating mode is enabled.
The symbol indicates that STOP operating mode is enabled (LED
13
is
illuminated).

MANUAL operating mode
Softkey
3


STOP operating mode


MANUAL Operating Mode



Start engine
Softkey
9

The "0" symbol indicates that a stop command is active.
The "1" symbol indicates that a start command is active.
The symbol indicates that monitoring functions are enabled.
The symbol indicates that speed is detected and the engine is running.
Stop engine
Softkey
9



Close breaker
Softkeys
10
or
11

The symbol indicates that voltage is detected at the respective
measuring point (generator, busbar, or mains).
The direction of the circular arrow indicates, if the generator or mains
rotating field is clockwise (CW) or counter-clockwise (CCW).
Open breaker
Softkeys
10
or
11


Voltage display


Toggle voltage display
Softkey
1

The voltage display softkey changes the type of voltage display.
The index of the "V" symbol indicates whether delta or wye voltage is
displayed and which phases are displayed.

* Dependent of the settings, this button may also be out of function (operating mode selection via LogicsManager)