You are on page 1of 68

Product

Data

40RM,
40RMQ,
40RMS
Packaged Air-Handling Units
50/60 Hz
6 to 30 Nominal Tons (21 to 105 kW) Cooling

Quality Assurance:
SAMCO
TUV CERT DIN ISO 9001
Certificate Reg. No. 041005420
Deutscher Akkreditierungs Rat (DAR)

Approvals:
ISO 9001
EN ISO 9001
ANSI/ASQC Q9001

Features / Benefits

40RM007S-012S
40RMQ008S,012S
40RMS008S-012S

40RM014S-034S
40RMQ016S
40RMS014S-034S

Carrier Corporation

Multiposition design can be installed


horizontally or vertically without
modification
Standard double skin units for a
better indoor air quality (IAQ)
Polyester powder painted zinc coated
steel panels provide additional protection against rusting & discoloration
in areas with high UV factor
High-static design meets a wider
range of applications than competitive packagedair handler lines
Economizer accessory provides ventilation air and ``free'' cooling
Cooling coils with mechanicallybonded fins provide peak heat
transfer
Hot water coil, steam coil, and electric heat accessoriesare available
Standard factory-installed thermostatic expansion valves(TXVs) on
40RM; 40RMQ units include TXVs
and check valves for heat pump duty
with matching 38AQS units
Standard sloped drain pans
1" WASHABLE filters having frontal
access to remove them
Easy installation and maintenance;
removal of one side panel allows
access to serviceable components;
external piping connections
The 40RM Seriesis your best choice
for packagedair handlers. Model
40RM and 40RMQ units have directexpansion coils and model 40RMS
units have chilled water coils. All models offer excellent fan performance,
a unique combination of indoor air
quality features, easy installation, and
affordable prices. Their versatility
and state-of-the-art features will provide economical performance now
and in the future.
Form 40RM-3PD-S

Indoor air quality features:


The unique combination of features
in the 40RM Series air handlers ensuresthat clean, fresh, conditioned air
is deliveredto the occupied space.
Cooling coils prevent the build-up
of humidity in the room, even during
part-load conditions. Unit sizes of
10 tons and above feature dual-circuit
face-split coils.
1 inch (25.4 mm) WASHABLE
air filters remove dust and airborne
particles from the occupied space.
Standard double skin units provide
an excellent resistance from the
air-borne particles off the insulation
thus maintaining an excellent indoor
air quality (IAQ).
Pitched drain pan can be adjusted
for a right- or left-hand connection to
provide positive drainage and prevent
standing condensate.
Accessory economizer can provide
ventilation air to improve indoor air
quality. When used with CO2 sensors,
the economizer admits fresh outdoor
air to replace stale, recirculated
indoor air.

Economy
The 40RM Series packaged air
handlers have low initial costs, and
they continue to savemoney by providing reducedinstallation expense
and energy-efficient performance.

Quick installation is ensuredby the


multiposition design. Units can be
installed in either the horizontal or
vertical (upflow) configuration without
modifications. All units have drainpan connections on both sides,and
pans can be pitched for right- or lefthand operation with a simple adjustment. Fan motors and contactors
are prewired and TXVs are factoryinstalled on 40RM and 40RMQ
models.
High efficiency, precision- balanced
fans minimize air turbulence, surging
and unbalanced operation, thereby
cutting operating expenses.
Economizer accessory precisely
controls the blend of outdoor air and
room air to achieve comfort levels.
When the outside air enthalpy is suitable, outside air dampers can fully
open to provide ``free'' cooling.

Coil flexibility
Model 40RM and 40RMQ (directexpansion coils) and 40RMS (chilled
water coils) have galvanized steel
casings; inlet and outlet connections
are external & on the same end.
Chilled water coils have 1/2 in.
(12.7 mm) diameter copper tubes mechanically bonded to aluminum sinewave fins. All coils have non-ferrous
headers.
Direct expansion (DX) coils are
designed for use with Refrigerant 22
and have copper tubes mechanically bonded to aluminum sine-wave
fins. Direct-expansion coils include
matched, factory-installed thermostatic
expansion valves(TXVs) with matching
distributor nozzles.

Easier installation and service:

The multi-position design and component layout help you to get the unit
Polyester powder painted (zinc coated)
installed and running quickly. The DX
panels provide excellent resistance to
coils have factory-installedTXVs with
corrosion and also protect the colour
matching distributor nozzles.Units can
in the areas where ultra-violet (UV)
be converted from horizontal to vertiradiation factor is high.
cal operation by simply repositionMechanically bonded coil fins pro- ing the unit. Drain pan connections
vide improved heat transfer.
are duplicated on both sidesof the
Galvanized steel fan housings are
unit. The filters, motor, drive, TXVs,
securely mounted to a die-formed
and coil connections are easily accessed
galvanized steel deck.
by removing a single side panels.
Rugged pillow-block bearings
(014-034 sizes) are securely fastened to the solid steel fan shaft with
split collets and clamp locking devices.

Rugged dependability

Table of contents
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PhysicalData . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Smaller unit sizeshave spider-type


bearings.

Page
1,2
3
4-9
10-12
13-22
23,24
25-43
44-50
51-54
55-63
64,65

Model number nomenclature


4 0 R M - 0 1 6 S D

40RM

B 5

E D

Commercial Packaged
Air Handler

Factory-Installed Options
GC
Unpainted, Standard Motor and
Standard Drive
HC
Unpainted, Standard Motor and
Medium-Static Drive (Not available
for 028 size for 60 Hz units and
016-028 for 50 Hz units)
TC
Unpainted, Alternate Motor and
Medium-Static Drive (Available for
50 Hz sizes 016,024,028 and
60 Hz size 028 only)
YC
Unpainted, Alternate Motor and
High-Static Drive
ED
Painted, Standard Motor and
Standard Drive
FD
Painted, Standard Motor and
Medium-Static Drive (Not available
for 028 size for 60 Hz units and
016-028 for 50 Hz units)
RD
Painted, Alternate Motor and
Medium-Static Drive (Available for
50 Hz sizes 016,024,028 and
60 Hz size 028 only)
WD
Painted, Alternate Motor and
High-Static Drive

Cooling Coil
Direct Expansion
Q
Direct Expansion for Heat Pump Duty*
S
Chilled Water
Nominal Capacity
007
6 (21)
008
7-1/2 (26)
010
8-1/2 (29)
012
10 (35)
014
12-1/2 (43)

Tons (kW)
016
15 (52)
024
20 (70)
028
25 (87)
034
30 (105)

S: SAMCO
D: Double Skin
Expansion Device
None (40RMS)
B
Thermostatic Expansion Valves (40RM, 40RMQ)
Voltage Designation (V-Ph-Hz)
1
575-3-60
3
208/230-1-60 (007-010 sizes only)
5
208/230-3-60
6
208/230/460-3-60 (all sizes 007-014; size 016
except YC and WD options)
460-3-60 (sizes 016 with YC or WD options and
all size 024-034 units)
8
230-3-50
9
400-3-50

Packaging
1
Standard Domestic
3
Export

Revision Number
0
Original Model
*For 40RMQ heat pump system performance information, refer to 38AQS Product Data catalog.
YC and WD option codes for all 034 size units and 008, 010 units with 208/230-1-60 power designate
standard motor and high-static drive.
NOTE: See the following table for the sizes available for each unit.

UNIT SIZE AVAILABILITY


UNIT
40RM
40RMQ
40RMS

007
X

008
X
X
X

010

012
X
X
X

014
X
X

016
X
X
X

024
X

028
X

034
X

Physical data
40RM - ENGLISH
UNIT 40RM
007SD
008SD
012SD
014SD
016SD
024SD
028SD
034SD
NOMINAL CAPACITY (Tons)
6
71/2
10
121/2
15
20
25
30
OPERATING WEIGHT (lb)
Base Unit (Double skin) with TXV
448
452
472
804
819
824
1188
1198
Plenum
97
97
97
140
140
140
180
180
FANS
Qty...Diam. (in.)
1...15
1...15
1...15
2...15
2...15
2...15
2...18
2...18
Nominal Airflow (cfm)
2400
3000
4000
5000
6000
8000
10,000
12,000
Airflow Range (cfm)
1800-3000 2250-3750 3000-5000 3750-6250 4500-7500 6000-10,000 7500-12,500 9000-15,000
Nominal Motor Hp (Standard Motor)*
208/230-1-60
1.3
2.4
208/230-3-60 and 460-3-60
2.4
2.4
2.4
2.9
3.7
5.0
7.5
10.0
575-3-60
1.0
2.0
2.0
3.0
3.0
5.0
7.5
10.0
230-3-50, 400-3-50
2.4
2.4
2.9
2.9
2.9
5.0
7.5
10.0
Motor Speed (rpm)
208/230-1-60
1725
1725
208/230-3-60 and 460-3-60
1725
1725
1725
1725
1725
1745
1745
1745
575-3-60
1725
1725
1725
1725
1725
1745
1755
1755
230-3-50, 400-3-50
1425
REFRIGERANT
R-22
Operating charge (lb)
3.0
3.0
1.5/1.5
2.0/2.0
2.5/2.5
3.5/3.5
4.5/4.5
5.0/5.0
(approx per circuit)
DIRECT-EXPANSION COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (psig)
435
Face Area (sq ft)
6.67
8.33
10.0
13.25
17.67
19.88
24.86
29.83
No. of Splits
1
1
2
2
2
2
2
2
Split Type...Percentage
Face...50/50
No. of Circuits per Split
12
15
9
9
12
13
15
18
Rows...Fins/in.
3...15
3...15
3...17
3...15
3...15
3...17
3...15
3...15
STEAM COIL
Max Working Pressure (psig at 400 F)
175
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
1...9
1...9
1...9
1...10
1...10
1...10
1...10
1...10
HOT WATER COIL
Max Working Pressure (psig)
150
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...12.5
2...12.5
Water Volume
(gal)
8.3
13.9
14.3
(ft3)
1.1
1.85
1.90
PIPING CONNECTIONS
Quantity...Size (in.)
DX Coil - Suction (ODF)
1...11/8
1...11/8
2...11/8
2...11/8
2...11/8
2...11/8
2...13/8
2...13/8
DX Coil - Liquid Refrigerant (ODF)
1...5/8
2...5/8
Steam Coil, In (MPT)
1...21/2
1...21/2
Steam Coil, Out (MPT)
1...11/2
1...11/2
Hot Water Coil, In (MPT)
1...11/2
1...11/2
1...2
Hot Water Coil, Out (MPT)
1...11/2
1...11/2
1...2
1/4
Condensate (PVC)
1...1 ODM/1 IDF
FILTERS
Washable - Factory Supplied
4...16 x 20 x 1
4...20 x 24 x 1
Quantity...Size (in.)
4...16 x 24 x 1
4...16 x 24 x 1
4...20 x 25 x 1
Access Location
Front
DX TXV -

LEGEND
Direct Expansion
Thermostatic Expansion Valve

*Refer to alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
Units are shipped without refrigerant charge.
Please contact your local Carrier sales office for the weights of single skin units.

40RM -

SI

UNIT 40RM
007SD
008SD
012SD
014SD
016SD
024SD
028SD
034SD
NOMINAL CAPACITY (kW)
21
26
35
43
52
70
87
105
OPERATING WEIGHT (kg)
Base Unit (Double skin) with TXV
203
205
214
364
371
373
538
542
Plenum
44
44
44
63
63
63
82
82
FANS
Qty...Diam. (mm)
1...381
1...381
1...381
2...381
2...381
2...381
2...457
2...457
Nominal Airflow (L/s)
1133
1604
1888
2360
2831
3775
4719
5663
Airflow Range (L/s)
850-1416 1203-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079
Nominal Motor kW (Standard Motor)*
208/230-1-60
0.97
1.79
208/230-3-60 and 460-3-60
1.79
1.79
1.79
2.16
2.76
3.73
5.59
7.46
575-3-60
0.75
1.49
1.49
2.24
2.24
3.73
5.59
7.46
230-3-50, 400-3-50
1.79
1.79
2.16
2.16
2.16
3.73
5.59
7.46
Motor Speed (r/s)
208/230-1-60
28.8
28.8
208/230-3-60 and 460-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.1
29.1
575-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.3
29.3
230-3-50, 400-3-50
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
REFRIGERANT
R-22
Operating charge (kg)
1.36
1.36
0.68/0.68 0.90/0.90 1.13/1.13 1.59/1.59 2.04/2.04 2.27/2.27
(approx per circuit)
DIRECT-EXPANSION COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (kPag)
2999
Face Area (sq m)
0.62
0.77
0.93
0.93
1.64
1.85
2.30
2.77
No. of Splits
1
1
2
2
2
2
2
2
No. of Circuits per Split
12
15
9
9
12
13
15
18
Split Type...Percentage
Face...50/50
Rows...Fins/m
3...591
3...591
3...670
3...591
3...591
3...670
3...591
3...591
STEAM COIL
Max Working Pressure (kPag at 204.4 C)
1207
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
1...355
1...355
1...355
1...394
1...394
1...394
1...394
1...394
HOT WATER COIL
Max Working Pressure (kPag)
1034
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
2...335
2...335
2...335
2...335
2...335
2...335
2...493
2...493
Water Volume
(L)
31.4
52.6
54.1
(m3)
0.031
0.052
0.054
PIPING CONNECTIONS**
Quantity...Size (in.)
DX Coil - Suction (ODF)
1...11/8
1...11/8
2...11/8
2...11/8
2...11/8
2...11/8
2...13/8
2...13/8
DX Coil - Liquid Refrigerant (ODF)
1...5/8
2...5/8
Steam Coil, In (MPT)
1...21/2
1...21/2
Steam Coil, Out (MPT)
1...11/2
1...11/2
Hot Water Coil, In (MPT)
1...11/2
1...11/2
1...2
Hot Water Coil, Out (MPT)
1...11/2
1...11/2
1...2
1/4
Condensate (PVC)
1...1 ODM/1 IDF
FILTERS
Washable - Factory Supplied
4...406 x 508 x 25.4
4...508 x 610 x 25.4
Quantity...Size
4...406 x 610 x 25.4
4...406 x 610 x 25.4
4...508 x 635 x 25.4
Access Location
Front
DX TXV -

LEGEND
Direct Expansion
Thermostatic Expansion Valve

*Refer to Alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
Units are shipped without refrigerant charge.
**All piping sizes are OD inches; equivalent sizes in millimeters follow:
in.
5/8

1
11/8
11/4
13/8
11/2
2
21/8
21/2

mm
15.9
25.4
28.6
31.8
34.9
38.1
50.8
54.0
63.5

Please contact your local Carrier sales office for the weights of single skin units.

Physical data (cont)


40RMQ - ENGLISH
UNIT 40RMQ
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
Base Unit (Double skin) with TXV
Plenum
FANS
Qty...Diam. (in.)
Nominal Airflow (cfm)
Airflow Range (cfm)
Nominal Motor Hp (Standard Motor)*
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
Motor Speed (rpm)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
REFRIGERANT
Operating charge (lb)
(approx per circuit)
DIRECT-EXPANSION COIL
Max Working Pressure (psig)
Face Area (sq ft)
No. of Splits
Split Type...Percentage
No. of Circuits per Split
Rows...Fins/in.
STEAM COIL
Max Working Pressure (psig at 400 F)
Total Face Area (sq ft)
Rows...Fins/in.
HOT WATER COIL
Max Working Pressure (psig)
Total Face Area (sq ft)
Rows...Fins/in.
Water Volume
(gal)
(ft3)
PIPING CONNECTIONS
Quantity...Size (in.)
DX Coil - Suction (ODF)
DX Coil - Liquid Refrigerant (ODF)
Steam Coil, In (MPT)
Steam Coil, Out (MPT)
Hot Water Coil, In (MPT)
Hot Water Coil, Out (MPT)
Condensate (PVC)
FILTERS
Quantity...Size (in.)
Access Location
DX TXV -

008SD
71/2

012SD
10

016SD
15

452
97

494
97

847
140

1...15
3000
2250-3750

1...15
4000
3000-5000

2...15
6000
4500-7500

2.4
2.4
2.0
2.4

2.4
2.0
2.9

3.7
3.0
2.9

1725
1725
1725

1725
1725
1425
R-22

3.0

1725
1725

2.0/2.0

3.0/3.0

Enhanced Copper Tubes, Aluminum Sine-Wave Fins


435
8.33
10.0
17.67
1
2
2
Face...50/50
15
9
16
3...15
4...15
4...15
6.67
1...9

175
6.67
1...9

13.33
1...10

6.67
2...8.5

150
6.67
2...8.5

13.33
2...8.5

8.3
1.1
1...11/8
1...5/8
1...21/2
1...11/2
1...11/2
1...11/2

13.9
1.85
2...11/8
2...5/8

2...11/8
2...5/8
1...21/2
1...11/2

1...11/2
1...2
1...11/2
1...2
1/4
1...1 ODM/1 IDF
Washable - Factory Supplied
4...16 x 20 x 1
4...16 x 24 x 1
4...16 x 24 x 1
Front

LEGEND
Direct Expansion
Thermostatic Expansion Valve

*Refer to the Alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
Units are shipped without refrigerant charge.
Please contact your local Carrier sales office for the weights of single skin units.

40RMQ - SI
UNIT 40RMQ
NOMINAL CAPACITY (kW)
OPERATING WEIGHT (kg)
Base Unit (Double skin) with TXV
Plenum
FANS
Qty...Diam. (mm)
Nominal Airflow (L/s)
Airflow Range (L/s)
Nominal Motor kW (Standard Motor)*
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
Motor Speed (r/s)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
REFRIGERANT
Operating charge (kg)
(approx per circuit)
DIRECT-EXPANSION COIL
Max Working Pressure (kPag)
Face Area (sq m)
No. of Splits
No. of Circuits per Split
Split Type...Percentage
Rows...Fins/m
STEAM COIL
Max Working Pressure (kPag at 204.4 C)
Total Face Area (sq m)
Rows...Fins/m
HOT WATER COIL
Max Working Pressure (kPag)
Total Face Area (sq m)
Rows...Fins/m
Water Volume
(L)
(m3)
PIPING CONNECTIONS**
Quantity...Size (in.)
DX Coil - Suction (ODF)
DX Coil - Liquid Refrigerant (ODF)
Steam Coil, In (MPT)
Steam Coil, Out (MPT)
Hot Water Coil, In (MPT)
Hot Water Coil, Out (MPT)
Condensate (PVC)
FILTERS
Quantity...Size
Access Location
DX TXV -

008SD
26

012SD
35

016SD
52

205
44

224
44

383
63

1...381
1604
1203-2006

1...381
1888
1416-2360

2...381
2831
2124-3539

1.79
1.79
1.49
1.79

1.79
1.49
2.16

2.76
2.24
2.16

28.8
28.8
28.8
23.8

28.8
28.8
23.8
R-22

28.8
28.8
23.8

1.36

0.91/0.91

1.36/1.36

2999
0.93
2
9

0.77
1
15
3...591

1.64
2
16

4...591

4...591

0.62
1...355

1207
0.62
1...355

1.24
1...394

0.62
2...335

1034
0.62
2...335

1.24
2...335

Face...50/50

31.4
0.031
1...11/8
1...5/8
1...21/2
1...11/2
1...11/2
1...11/2

52.6
0.052
2...11/8
2...5/8

2...11/8
2...5/8
1...21/2
1...11/2

1...11/2
1...2
1...11/2
1...2
1/4
1...1 ODM/1 IDF
Washable - Factory Supplied
4...406 x 508 x 25.4
4...406 x 610 x 25.4
4...406 x 610 x 25.4
Front

LEGEND
Direct Expansion
Thermostatic Expansion Valve

*Refer to the Alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
Units are shipped without refrigerant charge.
**All piping sizes are OD inches; equivalent sizes in millimeters follow:
in.
5/8

1
11/8
11/4
13/8
11/2
2
21/8
21/2

mm
15.9
25.4
28.6
31.8
34.9
38.1
50.8
54.0
63.5

Please contact your local Carrier sales office for the weights of single skin units.

Physical data (cont)


40RMS - ENGLISH
UNIT 40RMS
008SD
010SD
012SD
014SD
016SD
024SD
028SD
034SD
NOMINAL CAPACITY (Tons)
71/2
81/2
10
121/2
15
20
25
30
OPERATING WEIGHT (lb)
Base Unit (Double skin)
457
458
458
795
811
817
1203
1210
Plenum
97
97
97
140
140
140
180
180
FANS
Qty...Diam. (in.)
1...15
1...15
1...15
2...15
2...15
2...15
2...18
2...18
Nominal Airflow (cfm)
3000
3400
4000
5000
6000
8000
10,000
12,000
Airflow Range (cfm)
2250-3750 2250-4250 3000-5000 3750-6250 4500-7500 6000-10,000 7500-12,500 9000-15,000
Nominal Motor Hp
(Standard Motor)*
208/230-1-60
2.4
2.4
208/230-3-60 and 460-3-60
2.4
2.4
2.4
2.9
3.7
5.0
7.5
10.0
575-3-60
2.0
2.0
2.0
3.0
3.0
5.0
7.5
10.0
230-3-50, 400-3-50
2.4
2.4
2.9
2.9
2.9
5.0
7.5
10.0
Motor Speed (rpm)
208/230-1-60
1725
1725
208/230-3-60 and 460-3-60
1725
1725
1725
1725
1725
1745
1745
1745
575-3-60
1725
1725
1725
1725
1725
1745
1755
1755
230-3-50, 400-3-50
1425
CHILLED WATER COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (psig)
435
Face Area (sq ft) - Upper
8.3
9.0
9.8
8.3
8.3
11.0
12.4
15.5
Face Area (sq ft) - Lower
5.5
8.3
8.3
12.4
12.4
Rows...Fins/in.
3...15
Water Volume
(gal)
3.0
3.3
3.5
4.7
5.6
6.4
8.9
9.9
(ft3)
0.40
0.47
0.46
0.63
0.75
0.85
1.19
1.32
STEAM COIL
Max Working Pressure
175
(psig at 400 F)
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
1...9
1...9
1...9
1...10
1...10
1...10
1...10
1...10
HOT WATER COIL
Max Working Pressure (in. wg)
150
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...12.5
2...12.5
Water Volume
(gal)
8.3
13.9
14.3
(ft3)
1.1
1.85
1.90
PIPING CONNECTIONS
Quantity...Size (in.)
Chilled Water - In
1...13/8 ODF 1...13/8 ODF 1...13/8 ODF 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 2...21/8 ODM 2...21/8 ODM
Chilled Water - Out
1...13/8 ODF 1...13/8 ODF 1...13/8 ODF 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 2...21/8 ODM 2...21/8 ODM
Steam Coil, In (MPT)
1...21/2
1...21/2
Steam Coil, Out (MPT)
1...11/2
1...11/2
Hot Water Coil, In (MPT)
1...11/2
1...11/2
1...2
Hot Water Coil, Out (MPT)
1...11/2
1...11/2
1...2
1/4
Condensate (PVC)
1...1 ODM/1 IDF
FILTERS
Washable - Factory Supplied
4...16 x 20 x 1
4...20 x 24 x 1
Quantity...Size (in.)
4...16 x 24 x 1
4...16 x 24 x 1
4...20 x 25 x 1
Access Location
Front
*Refer to the Alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
Please contact your local Carrier sales office for the weights of single skin units.

40RMS - SI
UNIT 40RMS
NOMINAL CAPACITY (kW)
OPERATING WEIGHT (kg)
Base Unit (Double skin)
Plenum
FANS
Qty...Diam. (mm)
Nominal Airflow (L/s)
Airflow Range (L/s)

008SD
26

010SD
29

012SD
35

014SD
43

016SD
52

024SD
70

028SD
87

034SD
105

207
44

207
44

207
44

360
63

367
63

370
63

544
82

548
82

1...381
1416
10621770

1...381
1605
12042006

1...381
1888
14162360

2...381
2360
17702949

2...381
2831
21243539

2...381
3775
28314719

2...457
4719
35395899

2...457
5663
42477079

Nominal Motor kW
(Standard Motor)*
208/230-1-60
1.79
1.79
208/230-3-60, 460-3-60
1.79
1.79
1.79
1.79
2.76
3.73
5.59
7.46
575-3-60
1.49
1.49
1.49
1.49
2.24
3.73
5.59
7.46
230-3-50, 400-3-50
1.79
1.79
2.16
2.16
2.16
3.73
5.59
7.46
Motor Speed (r/s)
208/230-1-60
28.8
28.8
208/230-3-60, 460-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.1
29.1
575-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.3
29.3
230-3-50, 400-3-50
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
CHILLED WATER COIL
Max Working Pressure
2999
(kPag)
Face Area (sq m) - Upper
0.77
0.84
0.91
0.77
0.77
1.02
1.15
1.44
Face Area (sq m) - Lower
0.51
0.77
0.77
1.15
1.15
Rows...Fins/m
3...591
3...591
3...591
3...591
3...591
3...591
3...591
3...591
Water Volume
(L)
11.4
12.5
13.2
17.8
21.2
24.2
33.7
37.5
(M3)
0.011
0.013
0.013
0.018
0.021
0.024
0.032
0.037
STEAM COIL
Max Working Pressure
1207
(kPag at 204.4 C)
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
1...355
1...355
1...355
1...355
1...394
1...394
1...394
1...394
HOT WATER COIL
Max Working Pressure
1034
(kPag)
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
2...335
2...335
2...335
2...335
2...335
2...335
2...493
2...493
Water Volume
(L)
31.4
52.6
54.1
(m3)
0.031
0.052
0.054
PIPING CONNECTIONS
Quantity...Size (in.)
Chilled Water - In
1...13/8 ODF 1...13/8 ODF 2...13/8 ODF 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 2...21/8 ODM 2...21/8 ODM
Chilled Water - Out
1...13/8 ODF 1...13/8 ODF 2...13/8 ODF 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 2...21/8 ODM 2...21/8 ODM
Steam Coil, In (MPT)
1...21/2
1...21/2
Steam Coil, Out (MPT)
1...11/2
1...11/2
Hot Water Coil, In (MPT)
1...11/2
1...11/2
1...2
Hot Water Coil, Out (MPT)
1...11/2
1...11/2
1...2
1/4
Condensate (PVC)
1...1 ODM/1 IDF
FILTERS
Washable - Factory Supplied
4...406 x 508 x 25.4
4...508 x 610 x 25.4
Quantity...Size (mm)
4...406 x 610 x 25.4
4...406 x 610 x 25.4
4...508 x 635 x 25.4
Access Location
Front
*Refer to the Alternate Fan Motor Data table, pages 56 and 57, for alternate motor data.
All piping sizes are OD inches; equivalent sizes in millimeters follow:
in.
5/8

1
11/8
11/4
13/8
11/2
2
21/8
21/2

mm
15.9
25.4
28.6
31.8
34.9
38.1
50.8
54.0
63.5

Please contact your local Carrier sales office for the weights of single skin units.

Options and accessories


Factory-installed

options

Alter nate fan motors and drives are available to provide the widest possiblerange of performance.
Unpainted galvanized steel units are available from
the factory for applications that require unpainted units.
Please check for the availability & lead time.

Field-installed accessories
Two-row hot water coils have copper tubes mechanically bonded to aluminum plate fins and non-ferrous
headers.
One-row steam coil has copper tubes and aluminum fins.
The Inner Distributing Tube (IDT) design provides uniform
temperaturesacrossthecoil face.The steam coil hasa broad
operating pressure range; up to 175 psig (1207 kPag) at
400 F (204.4 C) and up to 300 psig (2069 kPag)at 300 F
(148.9 C). The IDT steam coils are especiallysuited to applications where sub-freezingair enters the unit.
Electric r esistance heat coils have an open-wire design
and are mounted in a rigid frame. Safety cutouts for high
temperature conditions are standard. Terminal block for
single-point power connection is included.
Economizer (enthalpy contr olled) provides ventilation
air and ``free'' cooling if outside ambient temperature and
humidity are suitable. Can also be used with CO2 sensors
to help meet indoor air quality requirements.
Discharge plenum directs the air discharge directly into
the occupied space; integral horizontal and vertical louvers
enable redirection of airflow. Accessory is available unpainted or painted. Field assemblyrequired.
Standard units available from the factory are in
Double skin, however units in Single skin can
also be ordered. Please check for the availability
and lead time.

10

Return-air grille provides a protective barrier over the


return-air opening and givesa finished appearanceto units
installed in the occupied space. Accessory is availableunpainted or painted.
Subbase provides a stable, raised platform and room for
condensatedrain trap connection for verticalfloor-mounted
units. Accessoryis availableunpainted or painted.
Over head suspension package includes necessary brackets to support units in horizontal ceiling installations.
CO 2 sensors can be used in conjunction with the economizer accessoryto help meet indoor air quality requirements. The sensor signals the economizer to open when
the CO2 level in the spaceexceedsthe set point. A Carrier
Comfort Systemprogrammable thermostat can be usedto
override the sensorif the outsideair temperature is too high
or too low.
Carrier's line of ther mostats provide both programmable and non-programmable capability with the new
Debonair line of commercial programmable thermostats,
the TEMP System controls offer communication capability with stagedheating and cooling, the Commercial Electronic thermostats provide 7-day programmable capability
for economicalapplications,while the Non-Programmable
thermostatsoffer a multitude of stagedheating and cooling
subbaseoptions.
Condensate drain trap includesan overflow shutoff switch
that can be wired to turn off the unit if the trap becomes
plugged. Kit also includesa wire harnessthat can be connected to an alarm if desired. The transparent trap is designed for easy serviceand maintenance.

CARRIER THERMOSTATS
DEBONAIR COMMERCIAL PROGRAMMABLE
THERMOSTAT

COMMERCIAL ELECTRONIC
THERMOSTAT

Carrier

Pm
COOL

AUTO
HEAT

TEMP SYSTEM THERMOSTAT

NON-PROGRAMMABLE THERMOSTAT
H

11

Options and accessories (cont)


40RM WITH DISCHARGE PLENUM,
RETURN-AIR GRILLE AND SUBBASE

40RM WITH HOT WATER OR STEAM COIL


HOT WATER OR
STEAM COIL

DISCHARGE
PLENUM

RETURN-AIR
GRILLE

SUBBASE
FAN
COIL
UNIT

40RM WITH ECONOMIZER

ECONOMIZER

12

FAN COIL
UNIT

40RM WITH CONDENSATE TRAP

Dimensions
40RM007SD-012SD
40RMQ008SD,012SD
40RMS008SD-012SD

UNIT

40RM007SD
40RM008SD
40RM012SD
40RMQ008SD
40RMQ012SD
40RMS008SD
40RMS010SD
40RMS012SD

UNIT WEIGHT
lb (kg)
448 (203)
452 (205)
472 (214)
452 (205)
494 (224)
457 (207)
458 (207)
458 (207)

All the above mentioned weights


are for double skin units.

TXV -

Thermostatic Expansion
Valve

NOTES:
1. Dimensions in [
millimeters.
2.

] are in

Direction of airow .

3. Recommended clearance:
Rear: 39(76.2 mm) (28-69[762 mm]
with electric heat accessory)
Front: 28-69 (762 mm)
Right side: 28-69 (762 mm)
Left Side: 28-69 (762 mm)
Local codes or jurisdiction may
prevail.
4. Liquid piping not supplied by
Carrier.
5. Duct flange is factory supplied and
field installed.

13

Dimensions (cont)
40RM014SD-024SD
40RMQ016SD
40RMS014SD-024SD

TXV -

Thermostatic Expansion
Valve

NOTES:
1. Dimensions in [ ] are in
millimeters.
2.
Direction of airflow.
3. Recommended clearance:
Rear: 39 (76.2 mm) (28-69
[762 mm] with electric heat
accessory)
Front: 28-69 (762 mm)
Right side: 28-69 (762 mm)
Left Side: 28-69 (762 mm)
Local codes or jurisdiction may
prevail.
4. Liquid piping not supplied by
Carrier.
5. Duct flange is factory supplied
and field installed.
UNIT

All the weights mentioned in the table


are for double skin
units.

14

40RM014SD
40RM016SD
40RM024SD
40RMQ016SD
40RMS014SD
40RMS016SD
40RMS024SD

UNIT WEIGHT
lb (kg)
804 (364)
819 (371)
824 (373)
847 (383)
795 (360)
811 (367)
817 (370)

40RM028SD,034SD
40RMS028SD,034SD

TXV -

Thermostatic Expansion
Valve

NOTES:
1. Dimensions in [ ] are in
millimeters.
2.
Direction of airflow.
3. Recommended clearance:
Rear: 39 (76.2 mm)
Front: 28-69 (762 mm)
Right side: 28-69 (762 mm)
Left Side: 28-69 (762 mm)
Local codes or jurisdiction may
prevail.
4. Liquid piping not supplied by
Carrier.
5. Duct flange is factory supplied
and field installed.
UNIT WEIGHT
lb (kg)
40RM028SD
1188 (538)
40RM034SD
1198 (542)
40RMS028SD
1203 (544)
40RMS034SD
1210 (548)
UNIT

All the above mentioned weights are for


double skin units.

15

Dimensions (cont)
OVERHEAD SUSPENSION ACCESSORY
UNIT SIZES 007-012

UNIT SIZES 014-024

UNIT SIZES 028,034

NOTE: Dimensions in [

16

] are millimeters.

PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES


UNIT SIZES 007-012

UNIT SIZES 014-024

NOTE: Dimensions in [

] are millimeters.

17

Dimensions (cont)
PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES (cont)
UNIT SIZES 028,034

NOTE: Dimensions in [

18

] are millimeters.

HOT WATER AND STEAM COIL ACCESSORIES


UNIT SIZES 007-012

NOTE: Dimensions in [

] are millimeters.

DIMENSION
A
B
C
D
E
F
G

HOT WATER COIL


1129 MPT [38.1]
1129 MPT [38.1]
[60.3]
2389
[123.8]
4789
[54.0]
2189
18-11149 [590.6]
38- 49 [1016.0]

STEAM COIL
1129 MPT [38.1]
2129 MPT [63.5]
3189
[79.4]
3189
[79.4]
49169
[115.8]
18-99
[584.2]
38-49 [1016.0]

DIMENSION
A
B
C
D
E
F
G

HOT WATER COIL


29 MPT [50.8]
29 MPT [50.8]
[60.3]
2389
[123.8]
4789
[54.0]
2189
18-11149 [590.6]
68- 89 [2032.0]

STEAM COIL
1129 MPT [38.1]
2129 MPT [63.5]
3189
[79.4]
3189
[79.4]
49169
[115.8]
18-99
[584.2]
68-89 [2032.0]

UNIT SIZES 014-024

NOTE : Dimensions in [

] are millimeters.

19

Dimensions (cont)
HOT WATER AND STEAM COIL ACCESSORIES (cont)
UNIT SIZES 028,034

DIMENSION
A
B
C
D
E
F
G
NOTE: Dimensions in [

20

] are millimeters.

HOT WATER COIL


29 MPT [50.8]
29 MPT [50.8]
[60.3]
2389
[123.8]
4789
[54.0]
2189
18-11149 [590.6]
78- 69 [2286.0]

STEAM COIL
1129 MPT [38.1]
2129 MPT [63.5]
3189
[79.4]
3189
[79.4]
49169
[115.8]
18-99
[584.2]
78-69 [2286.0]

ECONOMIZER ACCESSORY
UNIT SIZES 007-012

UNIT SIZES 014-024

UNIT SIZES 028,034

NOTES:
1. For horizontal unit applications, economizer can be attached to end of unit opposite duct connections.
2. Dimensions in [ ] are millimeters.

21

Dimensions (cont)
ELECTRIC HEAT ACCESSORY
UNIT SIZES 007-012

UNIT SIZES 014-034

UNIT SIZE
014-024
028,034

A
18-3149
[387.4]
18-3389
[390.5]

NOTE: Dimensions in [

22

B
48-6389
[1381.1]
58-47169
[1636.8]

] are millimeters.

C
25169
[58.7]
21169
[26.9]

D
28-1149
[641.4]
28-63169
[766.8]

E
10589
[269.9]
18-149
[311.2]

F
18-49
[406.4]
18-79
[482.6]

G
18-45169
[414.3]
18-45169
[414.0]

H
18-6349
[476.3]
18-109
[558.8]

J
18-789
[327.0]
18-47169
[417.1]

Selection procedure (with example)


English (60 Hz)
Cooling (DX)
I Determine the cooling load and temperature and
quantity of air entering the evaporator.
Given:
Total Capacity . . . . . . . . . . . . . . . . . . . . 200,000 Btuh
Sensible Heat Capacity . . . . . . . . . . . . . 130,000 Btuh
Air Temperature Entering Indoor
Coil . . . . . . . . . . . . . . . . . . . . . . . . 80 F db, 67 F wb
Air Quantity Entering Indoor Coil . . . . . . . 6000 cfm
Ductwork Static Pressure Loss . . . . . . . . . . 0.8 in. wg
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 230-3-60
II Determine unit selection and coil refrigerant
temperature.
Enter the Cooling Capacities table at 6000 cfm. Select a 40RM016 unit which has a total capacity of
207,000 and 174,000 Btuh at 40 and 45 F coil refrigerant temperature, respectively. By interpolation,
coil refrigerant temperature of 41.1 F is needed to give
a total capacity of 200,000 Btuh. Sensible capacity is
approximately 149,000 Btuh. Cooling load is
satisfied.

Heating (Hot Water Coil)


I Determine heating load and temperature of air
entering the indoor coil.
Given:
Load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425,000 Btuh
Entering-Air Temperature . . . . . . . . . . . . . . . . . . . 70 F
Coils. . . . . . . . . . . . . . . . . . . . . . . . . . 2-Row Hot Water
Coil Entering-Water Temperature . . . . . . . . . . . 200 F
Water Temperature Drop . . . . . . . . . . . . . . . . . . . 20 F
II Find the heating capacity.
Enter Hydronic Heating Capacities table for the
40RM016 unit at 6000 cfm. A 2-row hot water coil
delivers 471,000 Btuh (based on 60 F entering air
temperature and 20 F water temperature drop). Since
existing entering air temperature is 70 F, enter the
Heating Correction Factors table for hot water coils at
200 F entering water temperature, 20 F water temperature drop and 70 F entering air. Read a constant
of 0.93.
471,000 x 0.93 = 438,000
The 438,000 Btuh rating satisfies the heating load.

Fan
I Determine fan speed and brake horsepower:
From the Accessory Pressure Drop table, read a loss
of 0.23 in. wg for a hot water coil at 6000 cfm.
External static pressure = 0.80 + 0.23
= 1.03 in. wg
Enter 40RM016 Fan Performance table at 6000 cfm
and 1.03 in. wg. Interpolate and determine fan speed
of 866 rpm and 2.7 bhp.
II Determine motor and drive.
Enter the fan motor data tables on page 56, and find
that the 230 v standard motor for a 40RM016 unit is
rated at 3.7 Hp. Since the bhp required is 2.7, a standard motor satisfies the requirement and should be used.
Next, find the type of drive that satisfies the 866 rpm
requirement in the Drive Data tables on pages 58-60.
For a 40RM016 unit, the Medium-Static Drive table
on page 58 shows an rpm range of 742 to 943. Since
the rpm required is 866, the medium-static drive satisfies the requirement and should be used. Select the
standard motor and medium-static drive combination
(option code HC or FD).
To select an outdoor unit for this 40RM016 indoor
section, refer to the Combination Rating sheets for
Carrier condensing units in the condensing unit Product Data Digest, or consult the Carrier Electronic
Catalog.

Cooling (Chilled Water)


NOTE: Chilled water coils (40RMS) can be selected by using Carriers Electronic Catalog software program.

23

Selection procedure (with example)


SI (50 Hz)
Cooling (DX)
I Determine the cooling load and temperature and
quantity of air entering the evaporator.
Given:
Total Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . 37 kW
Sensible Heat Capacity . . . . . . . . . . . . . . . . . . . 29 kW
Air Temp Entering
Indoor Coil . . . . . . . . . . . . . . . . . 26.7 C db, 19 C wb
Air Quantity Entering Indoor Coil . . . . . . . 1900 L/s
Ductwork Static Pressure Loss . . . . . . . . . . . . 200 Pa
II Determine unit selection and coil refrigerant
temperature.
Enter the Cooling Capacities table at 1900 L/s.
Select a 40RM012 unit which has a total capacity of
37.35 kW at 6 C coil refrigerant temperature. Sensible
capacity is 29.61 kW. Cooling load is satisfied.

Heating (Hot Water Coil)


I Determine heating load and temperature of air
entering the indoor coil.
Given:
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 kW
Entering-Air Temperature . . . . . . . . . . . . . . . . 15.6 C
Coils . . . . . . . . . . . . . . . . . . . . . . . . . 2-Row Hot Water
Coil Entering-Water Temperature . . . . . . . . . . 93.3 C
Water Temperature Drop . . . . . . . . . . . . . . . . . 11.1 C
II Find the heating capacity.
Enter Hydronic Heating Capacities table for the
40RM012 unit at 1900 L/s. A 2-row hot water coil
delivers 90 kW (based on 15.6 C entering air temperature and 11.1 C water temperature drop).
The 90 kW rating satisfies the heating load.

24

Fan
I Determine fan speed and brake horsepower.
From the Accessory Pressure Drop table, read a loss
of 93 Pa for a hot water coil at 1900 L/s.
External static pressure = 200 + 93
= 293 Pa
Enter 40RM012 Fan Performance table at 1900 L/s
and 293 Pa. Interpolate and determine fan speed of
15.79 r/s and 1.41 kW.
II Determine motor and drive.
Enter the Fan Motor Data tables on page 57, and find
that the standard motor for a 40RM012 unit is rated
at 2.16 kW. Since the kW required is 1.41, a standard
motor satisfies the requirement and should be used.
Next, find the type of drive that satisfies the 15.79 r/s
requirement in the Drive Data tables on page 61-63.
For a 40RM012 unit, the Medium-Static Drive table
on page 63 shows an r/s range of 13.5 to 17.4. Since
the r/s required is 15.79, the medium-static drive satisfies the requirement and should be used. Select the
standard motor and medium-static drive combination
(option code HC or FD).
To select an outdoor unit for this 40RM012 indoor
section, refer to the Combination Rating sheets for Carrier condensing units in the condensing unit Product
Data Digest, or consult the latest Carrier Electronic
Catalog.

Cooling (Chilled Water)


NOTE: Select chilled water coils (40RMS) by using Carriers
Electronic Catalog software program.

Performance data
40RM COOLING CAPACITIES ENGLISH

UNIT
40RM

EVAPORATOR
AIR
Airflow
Ewb
(Cfm)
(F)
BF
1,800
0.06

007

2,400
0.10
3,000
0.12
2,250
0.06

008

3,000
0.10
3,750
0.12
3,000
0.05

012

4,000
0.07
5,000
0.12
3,750
0.06

014

5,000
0.08
6,250
0.10
4,500
0.03

016

6,000
0.05
7,500
0.08
6,000
0.03

024

8,000
0.06
10,000
0.07

72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62

COIL REFRIGERANT TEMP (F)


30

35

40

45

50

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

116
96
80
135
112
94
150
125
105
144
120
100
169
140
118
187
157
132
193
161
134
223
186
157
246
207
175
223
188
154
259
220
178
284
242
197
282
233
192
320
276
225
358
305
251
365
309
250
416
354
290
454
376
316

55
61
66
65
73
81
73
85
95
69
76
83
81
92
101
92
106
118
92
102
111
108
122
136
122
140
159
107
121
133
126
146
163
142
166
188
134
149
163
156
181
200
177
208
232
174
198
216
203
237
264
228
266
303

104
85
69
121
99
81
135
112
90
130
106
87
151
124
102
168
140
112
174
143
116
201
166
136
222
185
149
204
169
136
234
194
156
257
209
172
254
209
169
293
243
198
319
263
218
330
274
221
378
305
253
413
338
279

50
56
61
60
68
75
68
78
86
63
70
76
75
85
94
85
97
108
81
93
102
99
113
126
112
131
145
99
112
123
117
136
150
132
154
172
123
138
151
145
167
185
163
192
215
161
182
200
189
217
245
213
251
278

93
74
57
108
86
67
120
96
75
116
92
71
135
108
84
150
120
94
154
123
96
179
143
113
198
159
126
183
144
114
210
166
134
230
183
150
228
178
141
263
207
167
290
229
188
296
234
186
338
269
218
373
296
244

46
50
55
54
62
67
62
71
75
57
63
69
68
77
84
78
89
94
76
85
93
91
104
113
103
120
126
91
102
111
108
124
134
122
145
150
112
125
138
134
153
167
152
178
188
147
166
182
174
202
218
198
235
244

79
61
46
92
71
56
102
80
64
99
76
57
114
89
70
127
100
80
132
102
78
153
119
95
169
132
109
157
118
94
180
138
114
198
153
130
194
149
116
223
174
140
248
193
161
254
195
155
291
224
187
319
250
213

40
45
46
48
56
56
56
65
64
50
56
57
61
69
70
70
81
80
67
76
78
81
93
95
93
109
109
81
90
94
97
112
114
111
131
130
100
112
116
119
137
140
137
160
161
131
150
155
157
183
187
179
214
213

64
47
39
75
55
47
83
61
54
80
59
49
94
69
59
104
77
68
108
79
66
125
92
80
138
102
92
127
94
80
145
110
97
160
119
111
162
117
98
179
137
119
197
153
136
206
153
132
235
179
159
259
194
182

35
40
39
42
49
47
49
57
54
43
50
49
53
62
59
61
72
68
58
67
66
71
82
80
81
97
92
70
81
80
85
100
97
98
117
111
89
99
98
104
123
119
120
144
136
114
132
132
138
163
159
160
189
182

25

Performance data (cont)


40RM COOLING CAPACITIES ENGLISH (cont)

UNIT
40RM

EVAPORATOR
AIR
Airflow
Ewb
(Cfm)
(F)
BF
7,500
0.04

028

10,000
0.06
12,500
0.08
9,000
0.04

034

12,000
0.06
15,000
0.08

72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62

COIL REFRIGERANT TEMP (F)


30

35

45

50

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

440
374
303
498
425
350

456
380
527
449
364
598
510
420

547
456

211
241
265
246
288
325

327
375
253
290
318
295
346
390

392
450

394
385
270
454
373
306
495
408
336
473
402
323
545
448
367
594
490
403

193
225
247
229
267
302
258
308
336
232
270
297
275
321
362
309
370
403

361
287
229
408
327
267
445
359
299
433
345
275
490
393
321
534
431
359

180
205
226
212
249
267
240
289
299
216
246
271
254
298
321
288
347
359

312
235
193
354
271
232
385
304
264
375
282
232
425
326
279
462
365
317

162
184
193
193
226
232
220
265
264
194
221
232
232
271
279
264
318
317

255
191
165
288
220
199
318
239
226
306
229
198
346
263
238
382
287
271

142
166
165
170
203
199
198
235
226
170
199
198
205
244
238
237
282
271

LEGEND
BF
Bypass Factor
db
Dry-Bulb Temp (F)
Ewb Entering Wet-Bulb Temp (F)
lwb Leaving Wet-Bulb Temp (F)
SHC Sensible Heat Capacity (1000 Btuh)
TC
Total Capacity (1000 Btuh)
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. Evaporator fan heat not deducted from ratings.
3. Ratings based on approximately 15 F superheat leaving coil.
4. Dashes indicate coil loading limits are exceeded.
5. Formulas:
sensible heat capacity (Btuh)
Leaving db = entering db
1.1 x cfm
Leaving wb = wet-bulb temperature corresponding to enthalpy of
air leaving coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
where hewb = enthalpy of air entering coil

26

40

6. SHC is based on 80 F db temperature of air entering evaporator coil.


Below 80 F db, subtract (corr factor x cfm) from SHC.
Above 80 F db, add (corr factor x cfm) to SHC. See italic type
below.

BYPASS
FACTOR

79
81

0.02
0.05
0.10
0.15
0.20
0.25
0.30

1.08
1.05
0.99
0.94
0.88
0.83
0.77

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
Under 75
82
83
84
85
Over 85
Correction Factor
2.16 3.23 4.31 5.39
2.09 3.14 4.18 5.23
1.98 2.97 3.96 4.95
use formula
1.87 2.81 3.74 4.68
1.76 2.64 3.52 4.40 shown below
1.65 2.48 3.30 4.13
1.54 2.31 3.08 3.85

Interpolation is permissible.
Correction Factor = 1.1 x (1 BF) x (db 80)

40RM COOLING CAPACITIES SI

UNIT
40RM

EVAPORATOR
AIR
Airflow
Ewb
(L/s)
(C)
BF
850
.06

007

1150
.10
1450
.12
1000
.06

008

1400
.10
1800
.12
1450
.05

012

1900
.07
2350
.12
1750
.06

014

2350
.08
2950
.10
2100
.03

016

2800
.05
3500
.08
2900
.03

024

3800
.06
4700
.07

22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
16
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16

COIL REFRIGERANT TEMP (C)


1

10

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

33.73
27.79
22.73
39.24
32.37
26.41
43.88
36.69
29.14
42.12
34.64
28.76
49.07
40.52
33.30
54.60
45.87
36.21
56.46
46.83
38.11
65.14
54.26
44.18
71.98
60.62
47.82
65.89
55.70
44.35
75.61
63.64
50.09
83.01
67.98
54.67
82.25
68.47
55.23
94.97
79.48
64.12
102.66
85.35
69.63
106.58
89.80
71.75
122.11
99.07
80.95
133.27
109.55
88.34

16.27
18.51
21.09
19.50
22.21
25.86
21.85
25.31
29.14
20.58
23.22
26.41
24.22
27.88
32.38
27.31
31.43
36.21
26.00
30.42
34.82
31.89
36.83
43.13
35.85
42.44
47.82
31.93
36.93
42.14
37.49
44.28
50.09
42.04
49.45
54.67
39.79
45.43
51.82
46.65
54.48
63.23
51.90
62.06
69.63
52.05
59.51
68.29
60.50
69.97
80.95
67.86
80.54
88.34

32.43
26.56
21.58
37.73
30.93
25.15
42.16
35.04
27.82
40.51
33.11
27.26
47.14
38.72
31.70
52.46
43.80
34.59
54.28
44.73
36.21
62.64
51.85
42.12
69.21
57.89
45.79
63.44
53.09
42.24
72.79
60.75
47.97
79.93
65.08
52.53
79.12
65.39
52.57
91.32
75.93
61.19
98.96
81.75
66.75
102.62
85.74
68.44
117.57
94.89
77.60
128.35
104.99
84.97

15.75
17.93
20.29
18.87
21.58
24.85
21.22
24.63
27.82
19.89
22.48
25.39
23.49
27.04
31.12
26.52
30.60
34.59
25.26
29.53
33.56
30.94
35.78
41.49
34.85
41.30
45.79
30.98
35.77
40.60
36.44
43.02
47.97
40.94
48.26
52.53
38.58
44.06
49.96
45.28
52.91
60.85
50.54
60.40
66.75
50.46
57.82
65.88
58.81
68.20
77.60
66.08
78.62
84.97

29.83
24.10
19.27
34.70
28.06
22.64
38.71
31.74
25.19
37.29
30.05
24.26
43.29
35.13
28.48
48.17
39.68
31.35
49.91
40.53
32.39
57.64
47.03
37.99
63.67
52.41
41.72
58.55
47.85
38.02
67.15
54.97
43.71
73.75
59.28
48.24
72.88
59.24
47.23
84.03
68.84
55.34
91.55
74.54
60.99
94.70
77.63
61.79
108.48
86.53
70.90
118.51
95.88
78.24

14.69
16.78
18.70
17.60
20.32
22.64
19.97
23.30
25.19
18.52
21.01
23.38
22.02
25.38
28.48
24.95
28.96
31.35
23.80
27.76
31.04
29.05
33.70
37.99
32.86
39.02
41.72
29.09
33.46
37.55
34.34
40.53
43.71
38.75
45.89
48.24
36.16
41.32
46.25
42.55
49.78
55.34
47.82
57.09
60.99
47.29
54.44
61.08
55.45
64.66
70.90
62.52
74.79
78.24

27.23
21.64
16.95
31.68
25.18
20.11
35.26
28.44
22.55
34.07
26.97
21.25
39.43
31.54
25.25
43.89
35.55
28.10
45.53
36.32
28.56
52.64
42.19
33.85
58.13
46.93
37.66
53.65
42.61
33.78
61.51
49.19
39.44
67.58
53.48
43.96
66.62
53.07
41.88
76.72
61.73
49.48
84.14
67.33
55.23
86.78
69.50
55.13
99.38
78.16
64.19
108.68
86.76
71.50

13.64
15.63
16.95
16.34
19.08
20.11
18.72
21.99
22.55
17.16
19.55
21.25
20.56
23.74
25.25
23.40
27.35
28.10
22.33
26.01
28.55
27.17
31.64
33.85
30.89
36.77
37.66
27.21
31.18
33.78
32.26
38.06
39.44
36.57
43.57
43.96
33.74
38.61
41.88
39.83
46.68
49.48
45.12
53.84
55.23
44.13
51.08
55.13
52.11
61.17
64.19
58.97
71.01
71.50

24.62
19.17
14.62
28.66
22.30
17.58
31.82
25.14
19.91
30.84
23.89
18.22
35.57
27.94
22.01
39.61
31.42
24.85
41.15
32.10
24.71
47.63
37.35
29.71
52.59
41.45
33.59
48.75
37.35
29.53
55.87
43.40
35.17
61.41
47.68
39.67
60.37
46.89
36.52
69.42
54.62
43.61
76.73
60.11
49.45
78.85
61.37
48.45
90.29
69.79
57.48
98.84
77.65
64.76

12.60
14.51
14.62
15.09
17.86
17.58
17.50
20.73
19.91
15.80
18.12
18.22
19.12
22.15
22.01
21.87
25.81
24.85
20.89
24.29
24.71
25.30
29.61
29.71
28.93
34.59
33.59
25.34
28.93
29.53
30.19
35.64
35.17
34.42
41.33
39.67
31.34
35.94
36.52
37.13
43.64
43.61
42.46
50.69
49.45
40.98
47.75
48.45
48.79
57.74
57.48
55.46
67.33
64.76

22.02
16.70
12.28
25.63
19.41
15.04
28.37
21.83
17.26
27.61
20.80
15.17
31.71
24.33
18.76
35.32
27.28
21.59
36.77
27.87
20.85
42.62
32.51
25.55
47.05
35.97
29.52
43.85
32.09
25.27
50.23
37.61
30.90
55.23
41.88
35.38
54.10
40.70
31.13
62.11
47.50
37.72
69.32
52.89
43.67
70.92
53.21
41.75
81.19
61.41
50.76
89.00
68.53
58.02

11.57
13.41
12.28
13.89
16.79
15.04
16.33
19.63
17.26
14.46
16.74
15.17
17.72
20.67
18.76
20.41
24.47
21.59
19.47
22.64
20.85
23.47
27.68
25.55
27.03
32.55
29.52
23.49
26.75
25.27
28.16
33.33
30.90
32.34
39.29
35.38
28.97
33.33
31.13
34.48
40.72
37.72
39.90
47.79
43.67
37.84
44.47
41.75
45.52
54.46
50.76
52.01
63.85
58.02

19.40
14.22
9.93
22.60
16.51
12.49
24.92
18.52
14.61
24.37
17.71
12.10
27.85
20.71
15.50
31.04
23.14
18.33
32.38
23.64
16.97
37.61
27.65
21.37
41.51
30.49
25.44
38.94
26.81
20.98
44.58
31.81
26.62
49.06
36.08
31.10
47.84
34.50
25.73
54.80
40.37
31.82
61.90
45.66
37.88
62.99
45.05
35.03
72.10
53.03
44.03
79.16
59.41
51.28

10.57
12.41
9.93
12.66
15.64
12.49
23.63
18.52
14.61
13.18
15.49
12.10
16.48
19.62
15.50
19.32
23.14
18.33
18.13
21.21
16.97
21.73
26.01
21.37
25.31
30.49
25.44
21.73
24.76
20.98
26.26
31.36
26.62
30.52
36.08
31.10
26.65
30.88
25.73
31.95
38.14
31.82
37.72
45.66
37.88
34.74
41.29
35.03
42.39
51.58
44.03
48.77
59.41
51.28

27

Performance data (cont)


40RM COOLING CAPACITIES SI (cont)

UNIT
40RM

EVAPORATOR
AIR
Airflow Ewb
(L/s)
(C)
BF
3500
.04

028

4700
.06
5900
.08
4250
.04

034

5650
.06
7050
.08

22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16

COIL REFRIGERANT TEMP (C)


1

TC

SHC

125.95
131.38
86.95
146.03
121.55
97.09
159.37
131.94
105.39
151.16
132.16
103.92
175.30
145.93
116.36
191.24
158.48
126.37

61.58
73.49
83.51
72.86
85.85
97.09
81.76
98.52
105.39
74.13
88.16
100.45
87.47
103.33
116.36
97.85
118.39
126.37

TC

2
SHC

TC

SHC

TC

6
SHC

121.69
59.95 113.17
56.69 104.65
53.45
123.70
71.33 108.30
67.03
92.87
62.76
83.12
80.66 75.43
74.98
67.71
67.71
140.80
70.97 130.35
67.19 119.89
63.44
116.28
83.71 105.73
79.45
95.19
75.24
93.33
93.33 85.80
85.80
78.27
78.27
153.60
79.77 142.08
75.79 130.55
71.82
126.54
96.29 115.74
91.83 104.94
87.43
101.70 101.70 94.30
94.30
86.91
86.91
146.07
72.13 135.88
68.13 125.69
64.15
126.02
85.58 113.73
80.44 101.41
75.33
99.38
97.00 90.28
90.14
81.14
81.14
169.02
85.21 156.48
80.70 143.93
76.21
139.63 100.72 127.01
95.52 114.39
90.38
111.88 111.88 102.92 102.92
93.96
93.96
184.33
95.48 170.49
90.77 156.66
86.08
151.99 115.68 139.01 110.30 126.02 104.97
121.95 121.95 113.12 113.12 104.29 104.29

LEGEND
BF
Bypass Factor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
Ldb Leaving Dry Bulb
Lwb Leaving Wet Bulb
SHC Sensible Heating Capacity (kW)
TC
Total Capacity (kW)
NOTES:
1. Ratings based on approximately 8.3 C superheat leaving coil.
2. Direct interpolation is permissible. Do not extrapolate.
3. The SHC is based on 26.7 C db temperature of air entering the unit.
At any other temperature, correct the SHC reading from the table of
cooling capacities as follows:
Correction factor = 1.23 x 103 x (1 BF) x (db 26.7)
Above 26.7 C, add SHC correction to SHC. Below 26.7 C, subtract
SHC correction from SHC.

28

TC

SHC

TC

96.11
77.40
59.95
109.43
84.63
70.74
119.02
94.14
79.52
115.49
89.07
71.97
131.38
101.76
85.00
142.82
113.04
95.45

50.22
58.55
59.95
59.71
71.12
70.74
67.89
83.12
79.52
60.19
70.27
71.97
71.76
85.34
85.00
81.42
99.75
95.45

87.57
61.89
52.17
98.98
74.08
63.20
107.49
83.34
72.13
105.27
76.70
62.77
118.83
89.14
76.03
128.99
100.05
86.62

10
SHC

TC

SHC

47.04
79.02 43.94
54.43
46.34 46.34
52.17
44.34 44.34
56.05
88.52 52.56
67.17
63.52 63.52
63.20
55.66 55.66
64.01
95.96 60.28
78.97
72.54 72.54
72.13
64.73 64.73
56.27
95.05 52.43
65.32
64.29 60.59
62.77
53.52 53.52
67.38 106.28 63.19
80.49
76.50 76.18
76.03
67.06 67.06
76.84 115.15 72.42
94.74
87.07 87.07
86.62
77.78 77.78

4. Gross capacities shown do not include a deduction for evaporatorfan motor heat.
5. Formulas (cooling):
sensible heat capacity (kW)
tldb = tedb
1.23 x 10-3 x (L/s)
tlwb = wet-bulb temperature corresponding to enthalpy of air leaving coil (hlwb)
total capacity (kW)
hlwb = hewb
1.20 x 103 x (L/s)
where hewb = enthalpy of air entering coil (kJ/kg)

40RMQ COOLING CAPACITIES ENGLISH

UNIT
40RMQ

EVAPORATOR
AIR
Airflow
Ewb
(Cfm)
(F)
BF
2250
0.06

008

3000
0.10
3750
0.12
3000
0.05

012

4000
0.07
5000
0.12
4500
0.04

016

6000
0.04
7500
0.05

72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62

COIL REFRIGERANT TEMP (F)


30

35

40

45

50

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

144
120
100
169
140
118
187
157
132
193
161
134
223
186
157
246
207
175
310
258
213
366
304
254
409
339
285

69
76
83
81
92
101
92
106
118
92
102
111
108
122
136
122
140
159
147
161
175
176
196
217
199
227
255

130
106
87
151
124
102
168
140
112
174
143
116
201
166
136
222
185
149
282
231
185
331
272
219
371
303
244

63
70
76
75
85
94
85
97
108
81
93
102
99
113
126
112
131
145
135
148
161
161
182
201
185
211
236

116
92
71
135
108
84
150
120
94
154
123
96
179
143
113
198
159
126
250
199
154
293
234
181
327
263
205

57
63
69
68
77
84
78
89
94
76
85
93
91
104
113
103
120
126
122
135
146
146
166
181
168
194
205

99
76
57
114
89
70
127
100
80
132
102
78
153
119
95
169
132
109
212
165
122
248
194
148
277
217
172

50
56
57
61
69
70
70
81
80
67
76
78
81
93
95
93
109
109
107
120
122
130
149
148
150
176
172

80
59
49
94
69
59
104
77
68
108
79
66
125
92
80
138
102
92
175
126
102
205
149
125
228
168
146

43
50
49
53
62
59
61
72
68
58
67
66
71
82
80
81
97
92
93
105
102
114
132
125
132
156
146

LEGEND
BF
Bypass Factor
db
Dry-Bulb Temp (F)
Ewb Entering Wet-Bulb Temp (F)
lwb Leaving Wet-Bulb Temp (F)
SHC Sensible Heat Capacity (1000 Btuh)
TC
Total Capacity (1000 Btuh)
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. Evaporator fan heat not deducted from ratings.
3. Ratings based on approximately 15 F superheat leaving coil.
4. Formulas:
sensible heat capacity (Btuh)
Leaving db = entering db
1.1 x cfm
Leaving wb = wet-bulb temperature corresponding to enthalpy of
air leaving coil (hlwb)
total capacity (Btuh)
hlwb = hewb
4.5 x cfm
where hewb = enthalpy of air entering coil

5. SHC is based on 80 F db temperature of air entering evaporator coil.


Below 80 F db, subtract (corr factor x cfm) from SHC.
Above 80 F db, add (corr factor x cfm) to SHC. See italic type
below.

BYPASS
FACTOR

79
81

0.02
0.05
0.10
0.15
0.20
0.25
0.30

1.08
1.05
0.99
0.94
0.88
0.83
0.77

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
Under 75
82
83
84
85
Over 85
Correction Factor
2.16 3.23 4.31 5.39
2.09 3.14 4.18 5.23
1.98 2.97 3.96 4.95
use formula
1.87 2.81 3.74 4.68 shown
below
1.76 2.64 3.52 4.40
1.65 2.48 3.30 4.13
1.54 2.31 3.08 3.85

Interpolation is permissible.
Correction Factor = 1.1 x (1 BF) x (db 80)

29

Performance data (cont)


40RMQ COOLING CAPACITIES SI

UNIT
40RMQ

EVAPORATOR
AIR
Airflow
Ewb
(L/s)
(C)
BF
1000
.06

008

1400
.10
1800
.12
1450
.05

012

1900
.07
2350
.12
2100
.04

016

2800
.04
3500
.05

BF
Edb
Ewb
Ldb
Lwb
SHC
TC

22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16
22
19
16

COIL REFRIGERANT TEMP (C)


1

10

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

TC

SHC

42.12
34.64
28.76
49.07
40.52
33.30
54.60
45.87
36.21
56.46
46.83
38.11
65.14
54.26
44.18
71.98
60.62
47.82
91.80
75.66
61.18
107.87
89.13
71.93
121.08
99.24
79.29

20.58
23.22
26.41
24.22
27.88
32.38
27.31
31.43
36.21
26.00
30.42
34.82
31.89
36.83
43.13
35.85
42.44
47.82
44.17
48.99
56.01
52.14
59.53
69.52
59.76
68.38
79.29

40.51
33.11
27.26
47.14
38.72
31.70
52.46
43.80
34.59
54.28
44.73
36.21
62.64
51.85
42.12
69.21
57.89
45.79
88.16
72.28
58.01
103.54
85.12
68.35
116.17
94.81
75.63

19.89
22.48
25.39
23.49
27.04
31.12
26.52
30.60
34.59
25.26
29.53
33.56
30.94
35.78
41.49
34.85
41.30
45.79
42.69
47.51
53.92
50.51
57.81
66.73
57.92
66.56
75.63

37.29
30.05
24.26
43.29
35.13
28.48
48.17
39.68
31.35
49.91
40.53
32.39
57.64
47.03
37.99
63.67
52.41
41.72
80.87
65.51
51.67
94.89
77.11
61.19
106.35
85.93
68.32

18.52
21.01
23.38
22.02
25.38
28.48
24.95
28.96
31.35
23.80
27.76
31.04
29.05
33.70
37.99
32.86
39.02
41.72
39.73
44.55
49.75
47.27
54.40
61.19
54.26
62.96
68.32

34.07
26.97
21.25
39.43
31.54
25.25
43.89
35.55
28.10
45.53
36.32
28.56
52.64
42.19
33.85
58.13
46.93
37.66
73.57
58.73
45.31
86.24
69.08
54.01
96.52
77.04
61.00

17.16
19.55
21.25
20.56
23.74
25.25
23.40
27.35
28.10
22.33
26.01
28.55
27.17
31.64
33.85
30.89
36.77
37.66
36.78
41.62
45.31
44.04
51.05
54.01
50.62
59.43
61.00

30.84
23.89
18.22
35.57
27.94
22.01
39.61
31.42
24.85
41.15
32.10
24.71
47.63
37.35
29.71
52.59
41.45
33.59
66.27
51.94
38.92
77.57
61.05
46.81
86.70
68.15
53.67

15.80
18.12
18.22
19.12
22.15
22.01
21.87
25.81
24.85
20.89
24.29
24.71
25.30
29.61
29.71
28.93
34.59
33.59
33.84
38.73
38.92
40.86
47.81
46.81
47.03
56.05
53.67

27.61
20.80
15.17
31.71
24.33
18.76
35.32
27.28
21.59
36.77
27.87
20.85
42.62
32.51
25.55
47.05
35.97
29.52
58.97
45.13
32.51
68.91
53.00
39.59
76.87
59.26
46.33

14.46
16.74
15.17
17.72
20.67
18.76
20.41
24.47
21.59
19.47
22.64
20.85
23.47
27.68
25.55
27.03
32.55
29.52
30.93
35.92
32.51
37.79
44.90
39.59
43.59
53.09
46.33

24.37
17.71
12.10
27.85
20.71
15.50
31.04
23.14
18.33
32.38
23.64
16.97
37.61
27.65
21.37
41.51
30.49
25.44
51.65
38.31
26.06
60.23
44.93
32.34
67.04
50.35
38.98

13.18
15.49
12.10
16.48
19.62
15.50
19.32
23.14
18.33
18.13
21.21
16.97
21.73
26.01
21.37
25.31
30.49
25.44
28.08
33.27
26.06
35.23
43.44
32.34
63.63
50.35
38.98

LEGEND
Bypass Factor
Entering Dry Bulb
Entering Wet Bulb
Leaving Dry Bulb
Leaving Wet Bulb
Sensible Heating Capacity (kW)
Total Capacity (kW)

NOTES:
1. Ratings based on approximately 8.3 C superheat leaving coil.
2. Direct interpolation is permissible. Do not extrapolate.
3. The SHC is based on 26.7 C db temperature of air entering the unit.
At any other temperature, correct the SHC reading from the table of
cooling capacities as follows:
Correction factor = 1.23 x 103 x (1 BF) x (db 26.7)
Above 26.7 C, add SHC correction to SHC. Below 26.7 C, subtract
SHC correction from SHC.

30

4. Gross capacities shown do not include a deduction for evaporatorfan motor heat.
5. Formulas (cooling):
sensible heat capacity (kW)
tldb = tedb
1.23 x 10-3 x (L/s)
tlwb = wet-bulb temperature corresponding to enthalpy of air leaving coil (hlwb)
total capacity (kW)
hlwb = hewb
1.20 x 103 x (L/s)
where hewb = enthalpy of air entering coil (kJ/kg).

HYDRONIC HEATING CAPACITIES ENGLISH

40RM
007

1,800
2,400
3,000

146
173
209

134
126
123

2-ROW
HOT WATER COIL
Water
Cap.
Ldb
Flow
(Gpm)
156.0
140
15.6
183.0
131
18.3
206.0
124
20.6

40RM
40RMQ
40RMS
008

2,250
3,000
3,750

168
209
240

129
123
117

174.0
206.0
238.0

133
124
118

40RMS
010

2,550
3,400
4,250

183
229
254

125
121
114

199.0
233.0
271.0

40RM
40RMS
40RMQ
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

3,000
4,000
5,000

209
243
279

123
115
111

3,750
5,000
6,250

370
425
465

4,500
6,000
7,500
6,000
8,000
10,000
7,500
10,000
12,500
9,000
12,000
15,000

AIRFLOW
(Cfm)

UNIT

1-ROW
STEAM*
Cap.

Ldb

HYDRONIC HEATING CAPACITIES SI


AIRFLOW
(L/s)

UNIT
PD

1-ROW
STEAM*
Cap.

Ldb

2-ROW
HOT WATER COIL
Water
Cap.
Ldb
Flow
(L/s)
46
59
1.0
53
53
1.2
61
50
1.3

PD

3.4
4.3
5.2

40RM
007

850
1150
1450

43
53
62

57
53
51

10.2
12.8
16.0

17.4
20.6
23.8

4.0
5.2
6.5

40RM
40RMQ
40RMS
008

1000
1400
1800

48
59
71

55
50
47

50
60
70

56
50
47

1.1
1.3
1.5

11.5
15.3
19.5

132
123
119

19.9
23.3
27.1

4.5
5.7
7.2

40RMS
010

1200
1600
2000

54
64
74

52
48
46

58
69
79

55
50
48

1.3
1.5
1.7

13.4
17.3
21.4

299.0
275.0
316.0

152
124
119

29.9
27.5
31.6

5.0
6.6
8.2

1450
1900
2350

62
72
82

50
46
44

88
90
93

65
54
48

1.9
2.0
2.0

15.0
24.7
24.5

150
137
128

362.0
409.0
456.0

149
136
128

36.2
40.9
45.6

4.2
5.1
6.0

1750
2350
2950

108
122
136

66
58
53

106
120
134

65
57
52

2.3
2.6
2.9

12.4
15.2
17.9

402
458
479

141
129
118

412.0
471.0
529.0

145
133
125

41.2
47.1
52.9

4.5
5.5
6.6

2100
2800
3500

117
129
140

61
53
48

120
137
154

62
55
51

2.6
3.0
3.3

13.3
16.2
19.5

458
487
499
511
575
626
560
621
670

129
115
105
122
112
106
117
107
101

506.0
584.0
652.0
649.0
752.0
842.0
735.0
850.0
950.0

138
128
120
140
130
122
136
126
119

50.6
58.4
65.2
64.9
75.2
84.2
73.5
85.0
95.0

5.1
6.3
7.5
5.7
7.1
8.5
6.2
7.8
9.3

40RM
40RMS
40RMQ
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

2900
3800
4700
3500
4700
5900
4250
5650
7050

135
140
146
149
166
183
164
180
196

53
46
41
50
44
41
47
41
38

150
170
191
189
218
247
215
247
278

58
52
49
60
53
50
57
51
48

3.3
3.7
4.1
4.1
4.7
5.4
4.7
5.4
6.0

15.6
18.6
22.3
16.9
20.8
25.4
18.5
22.8
27.7

LEGEND
Cap. Capacity (Btuh in thousands)
Ldb Leaving-Air Dry-Bulb Temp (F)
PD
Pressure Drop (ft water)

LEGEND
Cap. Capacity (kW)
Ldb Leaving-Air Dry-Bulb Temp (C)
PD
Pressure Drop (kPa)

*Based on 5 psig steam, 60 F entering-air temperature. All steam coils are nonfreeze type.
Based on 200 F entering water, 20 F water temperature drop, 60 F entering-air
temperature.

*Based on 34.5 kPag steam, 15.6 C entering-air temperature. All steam coils are
non-freeze type.
Based on 93.3 C entering-water temperature, 11.1 C water temperature drop,
15.6 C entering-air temperature.

NOTES:
1. Maximum operating limits for heating coils: 175 psig at 400 F.
Capacity (Btuh)
2. Leaving db = ent db (F) +
1.1 x cfm
3. See Heating Correction Factors table.

NOTES:
1. Maximum operating limits for heating coils: 1207 kPag at 204.4 C.
Capacity (kW)
2. Leaving db = ent db (C) +
1.23 x 10-3 x L/s
3. See Heating Correction Factors table.

HEATING CORRECTION FACTORS SI

HEATING CORRECTION FACTORS ENGLISH


Water Temp
Drop
(F)
10

20

30

HOT WATER
Ent Water
Temp
40
(F)
140
0.72
160
0.89
180
1.06
200
1.22
220
1.39
140
0.64
160
0.81
180
0.98
200
1.15
220
1.32
140
0.56
160
0.74
180
0.91
200
1.08
220
1.25

Steam Pressure
(psig)
0
2
5

COIL
Entering-Air Temp (F)
50

60

70

80

0.64
0.81
0.98
1.15
1.32
0.57
0.74
0.91
1.08
1.25
0.49
0.66
0.83
1.00
1.18

0.57
0.74
0.90
1.07
1.24
0.49
0.66
0.83
1.00
1.17
0.41
0.58
0.76
0.93
1.10

0.49
0.66
0.83
1.00
1.17
0.41
0.58
0.75
0.93
1.10
0.33
0.51
0.68
0.85
1.03

0.41
0.58
0.75
0.92
1.09
0.33
0.51
0.68
0.85
1.02
0.24
0.43
0.60
0.78
0.95

STEAM COIL
Entering-Air Temp
40
50
60
1.06
0.98
0.91
1.09
1.02
0.95
1.13
1.06
1.00

(F)
70
0.85
0.89
0.93

80
0.78
0.82
0.87

NOTE: Multiply capacity given in the Hydronic Heating Capacities table by the
correction factor for conditions at which unit is actually operating. Correct leavingair temperature using formula in Note 2 of Hydronic Heating Capacities table.

Water Temp
Drop
(C)
5

11

16

HOT WATER
Ent Water
Temp
4
(C)
60
0.72
70
0.87
80
1.02
90
1.17
100
1.32
60
0.65
70
0.80
80
0.95
90
1.10
100
1.26
60
0.56
70
0.72
80
0.87
90
1.02
100
1.18

Steam Pressure
(kPag)
0
14
35

COIL
Entering-Air Temp (C)
10

16

20

25

0.64
0.79
0.94
1.09
1.24
0.56
0.72
0.87
1.02
1.18
0.48
0.63
0.79
0.94
1.10

0.55
0.71
0.86
1.01
1.16
0.48
0.63
0.79
0.94
1.09
0.39
0.55
0.70
0.86
1.02

0.50
0.65
0.80
0.95
1.10
0.42
0.58
0.73
0.89
1.04
0.33
0.49
0.65
0.81
0.97

0.43
0.58
0.73
0.89
1.04
0.35
0.51
0.66
0.82
0.97
0.26
0.42
0.58
0.74
0.90

STEAM COIL
Entering-Air Temp
4
10
16
1.07
0.99
0.91
1.10
1.02
0.95
1.14
1.07
0.99

(C)
20
0.86
0.90
0.95

25
0.80
0.84
0.89

NOTE: Multiply capacity given in the Hydronic Heating Capacities table by the
correction factor for conditions at which unit is actually operating. Correct leavingair temperature using formula in Note 2 of Hydronic Heating Capacities table.

31

Performance data (cont)


FAN PERFORMANCE DATA 0.0-1.2 in. wg ESP 60 Hz, ENGLISH

Rpm

Bhp

Rpm

Bhp

EXTERNAL STATIC PRESSURE (in. wg)


0.4
0.6
0.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp

40RM
007

1,800
2,100
2,400
2,700
3,000

320
373
427
480
533

0.22
0.31
0.42
0.54
0.69

442
483
526
570
616

0.32
0.42
0.53
0.67
0.82

534
569
606
646
687

0.42
0.53
0.64
0.78
0.94

611
642
676
712
750

0.52
0.63
0.75
0.89
1.05

678
708
739
773
808

40RM
40RMQ
40RMS
008

2,250
2,600
3,000
3,400
3,750

359
415
478
542
598

0.32
0.45
0.62
0.82
1.03

472
516
569
624
673

0.44
0.57
0.75
0.95
1.17

560
599
645
695
740

0.55
0.68
0.86
1.08
1.29

634
669
712
758
800

0.65
0.79
0.98
1.20
1.42

40RMS
010

2,550
2,975
3,400
3,825
4,250

396
462
527
593
659

0.42
0.60
0.80
1.05
1.33

502
556
612
670
729

0.54
0.72
0.93
1.18
1.47

586
634
684
737
791

0.65
0.84
1.06
1.31
1.60

658
701
748
797
848

40RM
40RMS
012

3,000
3,500
4,000
4,500
5,000

444
518
592
666
740

0.58
0.82
1.11
1.44
1.83

541
604
669
735
803

0.71
0.95
1.25
1.59
1.98

621
677
736
797
861

0.83
1.08
1.38
1.72
2.12

40RMQ
012

3,000
3,500
4,000
4,500
5,000

471
550
628
706
785

0.61
0.87
1.17
1.53
1.93

564
632
701
772
845

0.74
1.00
1.31
1.67
2.08

642
703
766
832
900

40RM
40RMS
014

3,750
4,300
5,000
5,700
6,250

363
416
484
552
605

0.37
0.53
0.81
1.17
1.51

475
517
573
631
678

0.58
0.78
1.08
1.47
1.83

40RM
40RMS
016

4,500
5,300
6,000
6,800
7,500

391
460
521
590
651

0.51
0.80
1.13
1.60
2.10

495
551
602
663
718

40RMQ
016

4,500
5,300
6,000
6,800
7,500

405
476
539
611
674

0.54
0.85
1.20
1.69
2.22

40RM
40RMS
024

6,000
7,000
8,000
9,000
10,000

503
586
670
754
838

40RM
40RMS
028

7,500
8,750
10,000
11,250
12,500

40RM
40RMS
034

9,000
10,500
12,000
13,500
15,000

UNIT

AIRFLOW
(Cfm)

0.0

1.0

1.2

Rpm

Bhp

Rpm

Bhp

0.61
0.73
0.86
1.00
1.16

739
767
796
828
862

0.70
0.82
0.96
1.11
1.28

795
821
849
880
912

0.80
0.92
1.06
1.21
1.39

700
732
773
815
855

0.75
0.90
1.09
1.31
1.60

759
790
828
869
906

0.86
1.01
1.20
1.43
1.66

814
843
879
918
954

0.96
1.11
1.32
1.55
1.78

0.76
0.95
1.18
1.44
1.73

722
762
806
852
901

0.87
1.06
1.30
1.56
1.86

780
818
860
904
950

0.97
1.18
1.41
1.68
1.98

833
870
910
952
997

1.08
1.29
1.53
1.80
2.11

691
742
797
854
914

0.94
1.20
1.51
1.86
2.26

753
801
853
907
964

1.05
1.32
1.63
1.99
2.39

809
855
904
956
1010

1.17
1.44
1.75
2.12
2.53

862
906
953
1003
1055

1.28
1.56
1.88
2.24
2.66

0.86
1.13
1.44
1.81
2.22

710
766
825
887
952

0.97
1.25
1.57
1.94
2.36

771
824
879
938
1000

1.09
1.37
1.69
2.07
2.50

827
877
930
987
1045

1.20
1.49
1.82
2.20
2.63

878
926
978
1032
1089

1.31
1.60
1.94
2.33
2.76

566
601
650
702
744

0.80
1.02
1.35
1.76
2.15

645
676
719
766
805

1.02
1.26
1.62
2.06
2.47

715
743
782
826
862

1.24
1.50
1.89
2.36
2.79

779
805
841
881
915

1.47
1.74
2.16
2.66
3.11

839
862
896
934
966

1.69
1.99
2.44
2.96
3.43

0.75
1.08
1.43
1.93
2.45

581
629
675
730
779

1.00
1.35
1.73
2.26
2.81

657
700
741
791
837

1.25
1.63
2.04
2.59
3.16

725
764
801
847
890

1.50
1.91
2.34
2.92
3.52

787
823
858
901
941

1.76
2.20
2.65
3.26
3.88

845
878
911
951
990

2.02
2.48
2.96
3.60
4.24

507
566
620
683
740

0.79
1.13
1.50
2.03
2.58

592
643
691
748
800

1.03
1.40
1.81
2.36
2.93

667
713
756
809
857

1.28
1.68
2.11
2.69
3.29

735
776
816
865
910

1.54
1.97
2.42
3.03
3.65

797
835
872
918
960

1.80
2.26
2.73
3.37
4.02

854
890
924
968
1008

2.06
2.55
3.05
3.71
4.38

1.07
1.64
2.37
3.28
4.39

587
660
735
812
891

1.37
1.98
2.74
3.69
4.83

661
726
795
867
941

1.67
2.31
3.12
4.09
5.27

727
787
851
918
988

1.97
2.65
3.49
4.50
5.70

789
844
904
967
1034

2.28
2.99
3.86
4.90
6.14

846
898
954
1014
1077

2.59
3.33
4.23
5.31
6.85

900
948
1001
1059
1120

2.90
3.67
4.61
5.72
7.02

412
481
549
618
687

1.15
1.76
2.55
3.52
4.71

492
550
610
672
735

1.53
2.17
2.99
4.00
5.22

568
616
669
725
783

2.00
2.66
3.50
4.53
5.78

640
680
726
777
830

2.56
3.22
4.07
5.12
6.38

710
742
782
827
876

3.22
3.86
4.70
5.76
7.04

776
802
836
876
922

3.98
4.58
5.40
6.45
7.74

840
860
889
925
966

4.83
5.38
6.17
7.21
8.49

471
550
628
707
785

1.78
2.72
3.93
5.44
7.27

539
608
679
752
826

2.17
3.15
4.40
5.94
7.81

604
665
730
797
867

2.63
3.64
4.92
6.49
8.39

667
720
779
841
907

3.17
4.18
5.48
7.08
9.01

728
774
827
885
947

3.78
4.79
6.09
7.71
9.66

788
827
874
928
986

4.46
5.45
6.76
8.38
10.35

845
878
921
970
1024

5.22
6.18
7.47
9.10
11.07

See Legend and Notes on page 36.

32

0.2

FAN PERFORMANCE DATA 1.4-2.4 in. wg ESP 60 Hz, ENGLISH

Rpm

Bhp

Rpm

EXTERNAL STATIC PRESSURE (in. wg)


1.8
2.0
2.2
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp

40RM
007

1,800
2,100
2,400
2,700
3,000

847
872
899
928
959

0.89
1.02
1.16
1.32
1.49

896
920
946
974
1004

0.98
1.11
1.26
1.42
1.60

942
965
990
1018
1046

1.07
1.21
1.36
1.52
1.71

986
1008
1033
1059
1087

1.16
1.30
1.46
1.63
1.81

1027
1050
1073
1099
1126

40RM
40RMQ
40RMS
008

2,250
2,600
3,000
3,400
3,750

865
893
928
965
1000

1.06
1.22
1.43
1.66
1.90

913
940
973
1010
1043

1.16
1.33
1.54
1.78
2.02

958
984
1017
1052
1084

1.27
1.43
1.65
1.89
2.13

1001
1027
1058
1092
1124

1.37
1.54
1.76
2.00
2.25

40RMS
010

2,550
2,975
3,400
3,825
4,250

884
919
957
998
1041

1.18
1.40
1.64
1.92
2.23

931
965
1002
1041
1083

1.29
1.51
1.76
2.04
2.35

975
1009
1044
1082
1123

1.40
1.62
1.87
2.16
2.48

1018
1050
1085
1122
1161

40RM
40RMS
012

3,000
3,500
4,000
4,500
5,000

911
953
999
1047
1097

1.39
1.67
2.00
2.37
2.79

958
998
1042
1089
1138

1.50
1.79
2.12
2.50
2.92

1002
1041
1084
1129
1177

1.61
1.90
2.24
2.62
3.05

40RMQ
012

3,000
3,500
4,000
4,500
5,000

927
973
1023
1075
1130

1.43
1.72
2.06
2.45
2.90

973
1018
1066
1116
1170

1.54
1.84
2.19
2.58
3.03

1017
1060
1107
1156

40RM
40RMS
014

3,750
4,300
5,000
5,700
6,250

894
916
948
984
1014

1.91
2.23
2.71
3.25
3.75

947
967
997
1031
1060

2.14
2.48
2.98
3.55
4.07

40RM
40RMS
016

4,500
5,300
6,000
6,800
7,500

899
930
961
999
1036

2.29
2.78
3.28
3.94
4.60

951
980
1009
1045
1080

40RMQ
016

4,500
5,300
6,000
6,800
7,500

908
941
974
1015
1054

2.33
2.84
3.36
4.05
4.75

40RM
40RMS
024

6,000
7,000
8,000
9,000
10,000

950
996
1047
1102
1160

40RM
40RMS
028

7,500
8,750
10,000
11,250
12,500

40RM
40RMS
034

9,000
10,500
12,000
13,500
15,000

UNIT

AIRFLOW
(Cfm)

1.4

1.6

2.4
Rpm

Bhp

1.25
1.40
1.55
1.73
1.92

1042
1067
1098
1131
1162

1.47
1.65
1.87
2.12
2.37

1.50
1.73
1.98
2.27
2.60

1059
1090
1124
1160
1199

1.61
1.84
2.10
2.39
2.72

1044
1082
1124
1168

1.72
2.02
2.36
2.74

1084
1122
1162

1.83
2.13
2.48

1123
1159
1199

1.94
2.25
2.60

1.65
1.95
2.31
2.71

1058
1101
1146
1194

1.76
2.07
2.43
2.83

1098
1139
1184

1.87
2.18
2.55

1137
1177

1.98
2.30

996
1016
1044
1076
1104

2.37
2.73
3.26
3.86
4.39

1044
1062
1089
1120
1147

2.60
2.98
3.53
4.16
4.71

1089
1107
1133
1162
1188

2.83
3.24
3.81
4.46
5.03

2.56
3.08
3.60
4.28
4.97

999
1027
1055
1089
1123

2.84
3.38
3.92
4.63
5.34

1046
1072
1098
1132
1164

3.12
3.68
4.24
4.98
5.71

1091
1116
1141
1173

3.41
3.99
4.57
5.33

1133
1157
1181

3.70
4.30
4.91

959
991
1022
1061
1098

2.61
3.14
3.69
4.40
5.12

1008
1038
1067
1104
1140

2.89
3.45
4.01
4.75
5.49

1054
1082
1111
1146
1181

3.17
3.75
4.34
5.10
5.86

1098
1126
1153
1187

3.46
4.06
4.67
5.46

1141
1167
1193

3.75
4.38
5.00

3.21
4.02
4.99
6.13
7.46

999
1042
1091
1143
1200

3.53
4.37
5.37
6.54
7.91

1045
1086
1133
1183

3.85
4.72
5.75
6.96

1089
1129
1173

4.17
5.07
6.13

1131
1169

4.50
5.43

1172

4.83

903
917
941
972
1010

5.79
6.26
7.01
8.02
9.29

963
972
991
1019
1053

6.83
7.22
7.91
8.89
10.15

1021
1025
1040
1064
1095

7.98
8.26
8.89
9.83
11.05

1078
1078
1089

9.21
9.38
9.93

901
928
966
1011
1062

6.07
6.98
8.24
9.86
11.84

955
978
1011
1052

6.98
7.84
9.07
10.67

1008
1026
1055
1092

7.98
8.76
9.95
11.52

1060
1073
1098

9.05
9.74
10.88

See Legend and Notes on page 36.

33

Performance data (cont)


FAN PERFORMANCE DATA 0.0-1.2 in. wg ESP 50 HZ, ENGLISH

Rpm

Bhp

Rpm

Bhp

EXTERNAL STATIC PRESSURE (in. wg)


0.4
0.6
0.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp

40RM
007

1,800
2,100
2,400
2,700
3,000

320
373
427
480
533

0.22
0.31
0.42
0.54
0.69

442
483
526
570
616

0.32
0.42
0.53
0.67
0.82

534
569
606
646
687

0.42
0.53
0.64
0.78
0.94

611
642
676
712
750

0.52
0.63
0.75
0.89
1.05

678
708
739
773
808

0.61
0.73
0.86
1.00
1.16

739
767
796
828
862

40RM
40RMQ
40RMS
008

2,250
2,600
3,000
3,400
3,750

359
415
478
542
598

0.32
0.45
0.62
0.82
1.03

472
516
569
624
673

0.44
0.57
0.75
0.95
1.17

560
599
645
695
740

0.55
0.68
0.86
1.08
1.29

634
669
712
758
800

0.65
0.79
0.98
1.20
1.42

700
732
773
815
855

0.75
0.90
1.09
1.31
1.60

40RMS
010

2,550
2,975
3,400
3,825
4,250

396
462
527
593
659

0.42
0.60
0.80
1.05
1.33

502
556
612
670
729

0.54
0.72
0.93
1.18
1.47

586
634
684
737
791

0.65
0.84
1.06
1.31
1.60

658
701
748
797
848

0.76
0.95
1.18
1.44
1.73

722
762
806
852
901

40RM
40RMS
012

3,000
3,500
4,000
4,500
5,000

444
518
592
666
740

0.58
0.82
1.11
1.44
1.83

541
604
669
735
803

0.71
0.95
1.25
1.59
1.98

621
677
736
797
861

0.83
1.08
1.38
1.72
2.12

691
742
797
854
914

0.94
1.20
1.51
1.86
2.26

40RMQ
012

3,000
3,500
4,000
4,500
5,000

471
550
628
706
785

0.61
0.87
1.17
1.53
1.93

564
632
701
772
845

0.74
1.00
1.31
1.67
2.08

642
703
766
832
900

0.86
1.13
1.44
1.81
2.22

710
766
825
887
952

40RM
40RMS
014

3,750
4,300
5,000
5,700
6,250

363
416
484
552
605

0.37
0.53
0.81
1.17
1.51

475
517
573
631
678

0.58
0.78
1.08
1.47
1.83

566
601
650
702
744

0.80
1.02
1.35
1.76
2.15

40RM
40RMS
016

4,500
5,300
6,000
6,800
7,500

391
460
521
590
651

0.51
0.80
1.13
1.60
2.10

495
551
602
663
718

0.75
1.08
1.43
1.93
2.45

581
629
675
730
779

40RMQ
016

4,500
5,300
6,000
6,800
7,500

405
476
539
611
674

0.54
0.85
1.20
1.69
2.22

507
566
620
683
740

0.79
1.13
1.50
2.03
2.58

40RM
40RMS
024

6,000
7,000
8,000
9,000
10,000

503
586
670
754
838

1.07
1.64
2.37
3.28
4.39

587
660
735
812
891

40RM
40RMS
028

7,500
8,750
10,000
11,250
12,500

412
481
549
618
687

1.15
1.76
2.55
3.52
4.71

40RM
40RMS
034

9,000
10,500
12,000
13,500
15,000

471
550
628
707
785

1.78
2.72
3.93
5.44
7.27

UNIT

AIRFLOW
(Cfm)

0.0

0.2

See Legend and Notes on page 36.

34

1.0
Rpm

1.2
Bhp

Rpm

Bhp

0.70
0.82
0.96
1.11
1.28

795
821
849
880
912

0.80
0.92
1.06
1.21
1.39

759
790
828
869
906

0.86
1.01
1.20
1.43
1.66

814
843
879
918
954

0.96
1.11
1.32
1.55
1.78

0.87
1.06
1.30
1.56
1.86

780
818
860
904
950

0.97
1.18
1.41
1.68
1.98

833
870
910
952
997

1.08
1.29
1.53
1.80
2.11

753
801
853
907
964

1.05
1.32
1.63
1.99
2.39

809
855
904
956
1010

1.17
1.44
1.75
2.12
2.53

862
906
953
1003
1055

1.28
1.56
1.88
2.24
2.66

0.97
1.25
1.57
1.94
2.36

771
824
879
938
1000

1.09
1.37
1.69
2.07
2.50

827
877
930
987
1045

1.20
1.49
1.82
2.20
2.63

878
926
978
1032
1089

1.31
1.60
1.94
2.33
2.76

645
676
719
766
805

1.02
1.26
1.62
2.06
2.47

715
743
782
826
862

1.24
1.50
1.89
2.36
2.79

779
805
841
881
915

1.47
1.74
2.16
2.66
3.11

839
862
896
934
966

1.69
1.99
2.44
2.96
3.43

1.00
1.35
1.73
2.26
2.81

657
700
741
791
837

1.25
1.63
2.04
2.59
3.16

725
764
801
847
890

1.50
1.91
2.34
2.92
3.52

787
823
858
901
941

1.76
2.20
2.65
3.26
3.88

845
878
911
951
990

2.02
2.48
2.96
3.60
4.24

592
643
691
748
800

1.03
1.40
1.81
2.36
2.93

667
713
756
809
857

1.28
1.68
2.11
2.69
3.29

735
776
816
865
910

1.54
1.97
2.42
3.03
3.65

797
835
872
918
960

1.80
2.26
2.73
3.37
4.02

854
890
924
968
1008

2.06
2.55
3.05
3.71
4.38

1.37
1.98
2.74
3.69
4.83

661
726
795
867
941

1.67
2.31
3.12
4.09
5.27

727
787
851
918
988

1.97
2.65
3.49
4.50
5.70

789
844
904
967
1034

2.28
2.99
3.86
4.90
6.14

846
898
954
1014
1077

2.59
3.33
4.23
5.31
6.85

900
948
1001
1059
1120

2.90
3.67
4.61
5.72
7.02

492
550
610
672
735

1.53
2.17
2.99
4.00
5.22

568
616
669
725
783

2.00
2.66
3.50
4.53
5.78

640
680
726
777
830

2.56
3.22
4.07
5.12
6.38

710
742
782
827
876

3.22
3.86
4.70
5.76
7.04

776
802
836
876
922

3.98
4.58
5.40
6.45
7.74

840
860
889
925
966

4.83
5.38
6.17
7.21
8.49

539
608
679
752
826

2.17
3.15
4.40
5.94
7.81

604
665
730
797
867

2.63
3.64
4.92
6.49
8.39

667
720
779
841
907

3.17
4.18
5.48
7.08
9.01

728
774
827
885
947

3.78
4.79
6.09
7.71
9.66

788
827
874
928
986

4.46
5.45
6.76
8.38
10.35

845
878
921
970
1024

5.22
6.18
7.47
9.10
11.07

FAN PERFORMANCE DATA 1.4-2.4 in. wg ESP 50 Hz, ENGLISH

Rpm

Bhp

Rpm

EXTERNAL STATIC PRESSURE (in. wg)


1.8
2.0
2.2
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp

40RM
007

1,800
2,100
2,400
2,700
3,000

847
872
899
928
959

0.89
1.02
1.16
1.32
1.49

896
920
946
974
1004

0.98
1.11
1.26
1.42
1.60

942
965
990
1018
1046

1.07
1.21
1.36
1.52
1.71

986
1008
1033
1059
1087

1.16
1.30
1.46
1.63
1.81

1027
1050
1073
1099
1126

40RM
40RMQ
40RMS
008

2,250
2,600
3,000
3,400
3,750

865
893
928
965
1000

1.06
1.22
1.43
1.66
1.90

913
940
973
1010
1043

1.16
1.33
1.54
1.78
2.02

958
984
1017
1052
1084

1.27
1.43
1.65
1.89
2.13

1001
1027
1058
1092
1124

1.37
1.54
1.76
2.00
2.25

40RMS
010

2,550
2,975
3,400
3,825
4,250

884
919
957
998
1041

1.18
1.40
1.64
1.92
2.23

931
965
1002
1041
1083

1.29
1.51
1.76
2.04
2.35

975
1009
1044
1082
1123

1.40
1.62
1.87
2.16
2.48

1018
1050
1085
1122
1161

40RM
40RMS
012

3,000
3,500
4,000
4,500
5,000

911
953
999
1047
1097

1.39
1.67
2.00
2.37
2.79

958
998
1042
1089
1138

1.50
1.79
2.12
2.50
2.92

1002
1041
1084
1129
1177

1.61
1.90
2.24
2.62
3.05

40RMQ
012

3,000
3,500
4,000
4,500
5,000

927
973
1023
1075
1130

1.43
1.72
2.06
2.45
2.90

973
1018
1066
1116
1170

1.54
1.84
2.19
2.58
3.03

1017
1060
1107
1156

40RM
40RMS
014

3,750
4,300
5,000
5,700
6,250

894
916
948
984
1014

1.91
2.23
2.71
3.25
3.75

947
967
997
1031
1060

2.14
2.48
2.98
3.55
4.07

40RM
40RMS
016

4,500
5,300
6,000
6,800
7,500

899
930
961
999
1036

2.29
2.78
3.28
3.94
4.60

951
980
1009
1045
1080

40RMQ
016

4,500
5,300
6,000
6,800
7,500

908
941
974
1015
1054

2.33
2.84
3.36
4.05
4.75

40RM
40RMS
024

6,000
7,000
8,000
9,000
10,000

950
996
1047
1102
1160

40RM
40RMS
028

7,500
8,750
10,000
11,250
12,500

40RM
40RMS
034

9,000
10,500
12,000
13,500
15,000

UNIT

AIRFLOW
(Cfm)

1.4

1.6

2.4
Rpm

Bhp

1.25
1.40
1.55
1.73
1.92

1042
1067
1098
1131
1162

1.47
1.65
1.87
2.12
2.37

1.50
1.73
1.98
2.27
2.60

1059
1090
1124
1160
1199

1.61
1.84
2.10
2.39
2.72

1044
1082
1124
1168

1.72
2.02
2.36
2.74

1084
1122
1162

1.83
2.13
2.48

1123
1159
1199

1.94
2.25
2.60

1.65
1.95
2.31
2.71

1058
1101
1146
1194

1.76
2.07
2.43
2.83

1098
1139
1184

1.87
2.18
2.55

1137
1177

1.98
2.30

996
1016
1044
1076
1104

2.37
2.73
3.26
3.86
4.39

1044
1062
1089
1120
1147

2.60
2.98
3.53
4.16
4.71

1089
1107
1133
1162
1188

2.83
3.24
3.81
4.46
5.03

2.56
3.08
3.60
4.28
4.97

999
1027
1055
1089
1123

2.84
3.38
3.92
4.63
5.34

1046
1072
1098
1132
1164

3.12
3.68
4.24
4.98
5.71

1091
1116
1141
1173

3.41
3.99
4.57
5.33

1133
1157
1181

3.70
4.30
4.91

959
991
1022
1061
1098

2.61
3.14
3.69
4.40
5.12

1008
1038
1067
1104
1140

2.89
3.45
4.01
4.75
5.49

1054
1082
1111
1146
1181

3.17
3.75
4.34
5.10
5.86

1098
1126
1153
1187

3.46
4.06
4.67
5.46

1141
1167
1193

3.75
4.38
5.00

3.21
4.02
4.99
6.13
7.46

999
1042
1091
1143
1200

3.53
4.37
5.37
6.54
7.91

1045
1086
1133
1183

3.85
4.72
5.75
6.96

1089
1129
1173

4.17
5.07
6.13

1131
1169

4.50
5.43

1172

4.83

903
917
941
972
1010

5.79
6.26
7.01
8.02
9.29

963
972
991
1019
1053

6.83
7.22
7.91
8.89
10.15

1021
1025
1040
1064
1095

7.98
8.26
8.89
9.83
11.05

1078
1078
1089

9.21
9.38
9.93

901
928
966
1011
1062

6.07
6.98
8.24
9.86
11.84

955
978
1011
1052

6.98
7.84
9.07
10.67

1008
1026
1055
1092

7.98
8.76
9.95
11.52

1060
1073
1098

9.05
9.74
10.88

See Legend and Notes on page 36.

35

Performance data (cont)


Bhp ESP -

LEGEND
Brake Horsepower Input to Fan
External Static Pressure

Bold indicates field supplied drive is required.


Plain type indicates standard motor and standard drive.
Underline indicates a different motor and drive combination other than
the standard motor and standard drive combination is required. Refer to
fan motor and drive tables, pages 56-63, to complete selection.
NOTES:
1. Maximum allowable fan speed is 1100 rpm for unit sizes 028 and
034; 1200 rpm for all other sizes.
2. Fan performance is based on deductions for wet coil, clean 1-in.
filters, and unit casing. See table at right for factory-supplied filter
pressure drop.
3. For 60 Hz units, the medium-static drive and standard motor combination is not available for 028 size. For 50 Hz units, the mediumstatic drive and standard motor combination is not available for
016-028 sizes. Use alternate motor if medium-static drive is required
for these sizes.

36

FACTOR Y-SUPPLIED FILTER PRESSURE DROP


- ENGLISH
AIRFLOW
(Cfm)
1,800
2,400
3,000

PRESSURE DROP
(in. wg)
0.05
0.08
0.11

40RM
40RMQ
40RMS
008

2,250
3,000
3,750

0.07
0.11
0.15

40RMS
010

2,550
3,400
4,250

0.09
0.13
0.18

3,000
4,000
5,000

0.11
0.17
0.23

3,750
5,000
6,250

0.06
0.10
0.13

4,500
6,000
7,500

0.08
0.12
0.17

6,000
8,000
10,000
7,500
10,000
12,500
9,000
12,000
15,000

0.12
0.19
0.26
0.15
0.22
0.30
0.19
0.29
0.40

UNIT
40RM
007

40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

FAN PERFORMANCE DATA 0-300 Pa ESP 60 Hz, SI


UNIT

AIRFLOW
(L/s)

50

EXTERNAL STATIC PRESSURE (Pa)


100
150
200
r/s
kW
r/s
kW
r/s
kW

r/s

kW

r/s

kW

40RM
007

850
1000
1150
1300
1450

5.34
6.28
7.22
8.17
9.11

0.17
0.24
0.33
0.43
0.55

7.38
8.10
8.86
9.64
10.50

0.25
0.32
0.41
0.52
0.64

8.91
9.53
10.20
10.90
11.60

0.32
0.40
0.50
0.61
0.73

10.20
10.80
11.40
12.00
12.70

0.39
0.48
0.58
0.69
0.82

11.30
11.80
12.40
13.00
13.60

40RM
40RMQ
40RMS
008

1000
1200
1400
1600
1800

5.63
6.76
7.89
9.01
10.10

0.22
0.32
0.46
0.62
0.80

7.61
8.49
9.42
10.40
11.40

0.30
0.41
0.55
0.71
0.90

9.11
9.88
10.70
11.60
12.50

0.38
0.50
0.64
0.80
0.10

10.40
11.10
11.80
12.60
13.50

0.45
0.57
0.72
0.89
1.09

40RMS
010

1200
1400
1600
1800
2000

6.58
7.67
8.77
9.86
11.00

0.31
0.44
0.60
0.78
0.99

8.35
9.25
10.20
11.10
12.10

0.40
0.54
0.70
0.88
1.09

9.76
10.60
11.40
12.30
13.20

0.49
0.63
0.79
0.98
1.19

11.00
11.70
12.50
13.30
14.10

40RM
40RMS
012

1450
1670
1900
2120
2350

7.58
8.73
9.93
11.10
12.30

0.46
0.63
0.84
1.08
1.36

9.18
10.20
11.20
12.20
13.30

0.56
0.73
0.95
1.18
1.17

10.50
11.40
12.30
13.30
14.30

0.65
0.83
1.05
1.29
1.57

40RMQ
012

1450
1670
1900
2120
2350

8.04
9.26
10.50
11.80
13.00

0.49
0.67
0.89
1.14
1.43

9.57
10.60
11.80
12.90
14.00

0.58
0.77
0.99
1.24
1.54

10.90
11.80
12.80
13.90
15.00

40RM
40RMS
014

1750
2050
2350
2650
2950

5.99
7.01
8.04
9.07
10.10

0.27
0.41
0.60
0.84
1.13

7.88
8.68
9.53
10.40
11.30

0.43
0.60
0.81
1.06
1.37

40RM
40RMS
016

2100
2450
2800
3150
3500

6.43
7.51
8.58
9.65
10.70

0.37
0.57
0.82
1.14
1.52

8.19
9.06
9.96
10.90
11.90

40RMQ
016

2100
2450
2800
3150
3500

6.65
7.76
8.87
9.98
11.10

0.39
0.60
0.86
1.19
1.59

40RM
40RMS
024

2900
3350
3800
4250
4700

8.58
9.91
11.30
12.60
13.90

40RM
40RMS
028

3500
4100
4700
5300
5900

40RM
40RMS
034

4250
4950
5650
6350
7050

250

300

r/s

kW

r/s

kW

0.46
0.55
0.66
0.77
0.91

12.30
12.80
13.40
13.90
14.50

0.53
0.63
0.73
0.85
0.99

13.30
13.70
14.20
14.80
15.40

0.60
0.70
0.81
0.93
1.07

11.50
12.10
12.80
13.60
14.40

0.53
0.66
0.81
0.98
1.18

12.50
13.10
13.80
14.50
15.20

0.61
0.74
0.89
1.07
1.27

13.40
14.00
14.60
15.30
16.00

0.68
0.82
0.97
1.16
1.36

0.57
0.71
0.88
1.07
1.29

12.00
12.70
13.40
14.20
15.00

0.65
0.80
0.97
1.16
3.38

13.00
13.60
14.30
15.10
15.80

0.73
0.88
1.05
1.25
1.48

13.90
14.50
15.20
15.90
16.60

0.81
0.96
1.14
1.34
1.57

11.60
12.50
13.30
14.20
15.20

0.73
0.92
1.14
1.39
1.68

12.70
13.40
14.30
15.10
16.00

0.82
1.01
1.24
1.48
1.78

13.60
14.30
15.10
15.90
16.80

0.90
1.10
1.33
1.58
1.88

14.50
15.20
15.90
16.70
17.60

0.99
1.18
1.42
1.68
1.98

0.67
0.86
1.09
1.35
1.65

12.00
12.90
13.80
14.80
15.80

0.76
0.95
1.19
1.45
1.75

13.00
13.80
14.70
15.60
16.60

0.85
1.04
1.28
1.55
1.85

13.90
14.70
15.60
16.40
17.40

0.93
1.13
1.38
1.64
1.95

14.80
15.50
16.40
17.20
18.10

1.02
1.22
1.47
1.74
2.05

9.41
10.10
10.80
11.60
12.40

0.59
0.78
1.01
1.28
1.61

10.70
11.30
12.00
12.70
13.40

0.75
0.96
1.21
1.50
1.85

11.90
12.40
13.00
13.70
14.40

0.92
1.14
1.41
1.72
2.08

13.00
13.50
14.00
14.60
15.30

1.08
1.33
1.61
1.94
2.32

14.00
14.40
14.90
15.50
16.10

1.25
1.51
1.82
2.16
2.56

0.55
0.77
1.05
1.38
1.78

9.65
10.40
11.20
12.00
12.90

0.73
0.97
1.27
1.63
2.05

10.90
11.60
12.30
13.10
13.90

0.92
1.18
1.49
1.87
2.31

12.10
12.70
13.30
14.00
14.80

1.11
1.39
1.72
2.12
2.58

13.10
13.70
14.30
14.90
15.60

1.30
1.60
1.95
2.36
2.84

14.10
14.60
15.10
15.80
16.40

1.50
1.81
2.18
2.61
3.11

8.39
9.30
10.20
11.20
12.20

0.58
0.81
1.09
1.44
1.86

9.83
10.60
11.50
12.30
13.20

0.76
1.01
1.32
1.70
2.14

11.10
11.80
12.50
13.40
14.20

0.95
1.22
1.55
1.95
2.41

12.20
12.90
13.60
14.30
15.10

1.13
1.43
1.78
2.20
2.68

13.30
13.80
14.50
15.20
15.90

1.31
1.63
2.01
2.45
2.95

14.20
14.80
15.40
16.00
16.70

1.50
1.84
2.24
2.70
3.22

0.86
1.28
1.81
2.46
3.24

9.96
11.10
12.30
13.60
14.80

1.09
1.53
2.09
2.76
3.57

11.20
12.20
13.30
14.50
15.60

1.32
1.79
2.37
3.07
3.90

12.30
13.20
14.30
15.30
16.40

1.55
2.04
2.64
3.37
4.22

13.30
14.20
15.10
16.10
17.20

1.78
2.30
2.93
3.67
4.55

14.20
15.10
16.00
16.90
17.90

2.01
2.55
3.21
3.98
4.88

15.10
15.90
16.80
17.70
18.60

2.25
2.81
3.49
4.28
5.21

6.79
7.95
9.12
10.30
11.40

0.84
1.29
1.88
2.62
3.52

8.14
9.12
10.10
11.20
12.30

1.12
1.60
2.21
3.00
3.90

9.42
10.20
11.10
12.10
13.10

1.47
1.96
2.59
3.37
4.32

10.70
11.30
12.10
12.90
13.90

1.89
2.38
3.02
3.81
4.77

11.80
12.40
13.00
13.80
14.60

2.39
2.86
3.49
4.29
5.26

12.90
13.40
13.90
14.60
15.40

2.96
3.40
4.02
4.82
5.79

14.00
14.30
14.80
15.40
16.10

3.61
4.00
4.60
5.38
6.35

7.86
9.15
10.40
11.70
13.00

1.33
2.03
2.92
4.02
5.37

8.99
10.10
11.30
12.50
13.70

1.63
2.35
3.27
4.40
5.77

10.10
11.10
12.20
13.30
14.40

1.97
2.72
3.66
4.81
6.21

11.10
12.00
13.00
14.00
15.10

2.37
3.12
4.08
5.25
6.66

12.20
12.90
13.80
14.70
15.70

2.83
3.58
4.54
5.72
7.15

13.20
13.80
14.60
15.50
16.40

3.34
4.08
5.04
6.23
7.67

14.10
14.70
15.40
16.20
17.10

3.92
4.62
5.57
6.77
8.21

See Legend and Notes on page 41.

37

Performance data (cont)


FAN PERFORMANCE DATA 350-600 Pa ESP 60 Hz, SI
UNIT

AIRFLOW
(L/s)

350

400

EXTERNAL STATIC PRESSURE (Pa)


450
500
r/s
kW
r/s
kW

r/s

kW

r/s

kW

40RM
007

850
1000
1150
1300
1450

14.10
14.60
15.10
15.60
16.10

0.67
0.77
0.88
1.01
1.15

15.00
15.40
15.90
16.40
16.90

0.74
0.84
0.96
1.09
1.24

15.70
16.10
16.60
17.10
17.60

0.81
0.91
1.03
1.17
1.32

16.50
16.90
17.30
17.80
18.30

40RM
40RMQ
40RMS
008

1000
1200
1400
1600
1800

14.30
14.80
15.40
16.10
16.80

0.76
0.90
1.06
1.24
1.45

15.10
15.60
16.20
16.80
17.50

0.83
0.98
1.14
1.33
1.54

15.80
16.40
16.90
17.50
18.20

0.91
1.05
1.22
1.41
1.63

40RMS
010

1200
1400
1600
1800
2000

14.70
15.30
16.00
16.60
17.30

0.89
1.05
1.23
1.43
1.66

15.50
16.10
16.70
17.40
18.00

0.97
1.13
1.31
1.52
1.76

16.30
16.80
17.40
18.10
18.70

40RM
40RMS
012

1450
1670
1900
2120
2350

15.30
16.00
16.70
17.50
18.30

1.07
1.27
1.51
1.77
2.07

16.10
16.70
17.40
18.20
19.00

1.15
1.36
1.60
1.86
2.17

40RMQ
012

1450
1670
1900
2120
2350

15.60
16.30
17.10
17.90
18.80

1.10
1.31
1.56
1.83
2.15

16.30
17.00
17.80
18.60
19.50

40RM
40RMS
014

1750
2050
2350
2650
2950

14.90
15.30
15.80
16.30
16.90

1.42
1.70
2.02
2.39
2.80

40RM
40RMS
016

2100
2450
2800
3150
3500

15.00
15.50
16.00
16.60
17.20

40RMQ
016

2100
2450
2800
3150
3500

40RM
40RMS
024

550

600

r/s

kW

r/s

kW

0.87
0.98
1.11
1.25
1.40

17.20
17.60
18.00
18.40
18.90

0.94
1.06
1.18
1.32
1.48

16.60
17.10
17.60
18.20
18.90

0.99
1.13
1.30
1.50
1.72

17.30
17.80
18.30
18.90
19.50

1.06
1.21
1.39
1.58
1.80

1.05
1.21
1.40
1.61
1.85

17.00
17.50
18.10
18.70
19.40

1.12
1.29
1.48
1.70
1.94

17.70
18.20
18.80
19.40

1.20
1.37
1.57
1.79

16.80
17.40
18.10
18.80
19.60

1.24
1.44
1.69
1.96
2.27

17.50
18.10
18.80
19.50

1.32
1.53
1.78
2.05

18.20
18.80
19.40

1.40
1.62
1.87

18.80
19.40

1.48
1.70

1.18
1.40
1.65
1.93
2.25

17.10
17.80
18.50
19.30

1.27
1.48
1.74
2.02

17.80
18.40
19.20
19.90

1.35
1.57
1.83
2.11

18.40
19.10
19.80

1.43
1.66
1.92

19.10
19.70

1.52
1.74

15.80
16.20
16.60
17.10
17.70

1.58
1.88
2.22
2.61
3.04

16.60
17.00
17.40
17.90
18.40

1.75
2.07
2.43
2.83
3.28

17.40
17.80
18.20
18.60
19.10

1.93
2.26
2.64
3.06
3.53

18.20
18.50
18.90
19.30
19.80

2.10
2.45
2.84
3.28
3.77

1.70
2.03
2.42
2.87
3.38

15.80
16.30
16.80
17.40
18.00

1.90
2.25
2.66
3.12
3.65

16.70
17.10
17.60
18.10
18.70

2.11
2.47
2.90
3.38
3.93

17.40
17.80
18.30
18.80
19.40

2.32
2.70
3.14
3.64
4.20

18.20
18.60
19.00
19.50

2.53
2.93
3.38
3.90

18.90
19.30
19.70

2.74
3.16
3.63

15.10
15.60
16.20
16.80
17.50

1.68
2.05
2.47
2.95
3.49

16.00
16.40
17.00
17.60
18.20

1.87
2.25
2.69
3.19
3.76

16.80
17.20
17.80
18.30
19.00

2.06
2.46
2.92
3.44
4.03

17.50
18.00
18.50
19.00
19.60

2.24
2.67
3.15
3.69
4.30

18.30
18.70
19.20
19.70

2.43
2.88
3.38
3.94

19.00
19.40
19.80

2.62
3.09
3.61

2900
3350
3800
4250
4700

16.00
16.70
17.50
18.40
19.30

2.49
3.08
3.77
4.59
5.54

16.80
17.50
18.20
19.10
20.00

2.73
3.34
4.06
4.90
5.87

17.50
18.20
18.90
19.80

2.97
3.61
4.35
5.21

18.30
18.90
19.60

3.22
3.87
4.64

19.00
19.60

3.47
4.14

19.70

3.72

40RM
40RMS
028

3500
4100
4700
5300
5900

15.10
15.30
15.70
16.20
16.90

4.33
4.67
5.23
5.99
6.95

16.10
16.20
16.50
17.00
17.60

5.12
5.39
5.91
6.65
7.59

17.10
17.10
17.40
17.80
18.30

5.98
6.18
6.64
7.35
8.27

18.00
18.00
18.20

6.92
7.02
7.43

40RM
40RMS
034

4250
4950
5650
6350
7050

15.00
15.50
16.10
16.90
17.70

4.55
5.22
6.16
7.34
8.79

16.00
16.30
16.90
17.50
18.30

5.24
5.86
6.77
7.94
9.39

16.80
17.10
17.60
18.20

5.99
6.56
7.43
8.58

17.70
17.90
18.30

6.79
7.30
8.13

See Legend and Notes on page 41.

38

FAN PERFORMANCE DATA 0-300 Pa ESP 50 Hz, SI


UNIT

AIRFLOW
(L/s)

50

EXTERNAL STATIC PRESSURE (Pa)


100
150
200
r/s
kW
r/s
kW
r/s
kW

r/s

kW

r/s

kW

40RM
007

850
1000
1150
1300
1450

5.34
6.28
7.22
8.17
9.11

0.17
0.24
0.33
0.43
0.55

7.38
8.10
8.86
9.64
10.50

0.25
0.32
0.41
0.52
0.64

8.91
9.53
10.20
10.90
11.60

0.32
0.40
0.50
0.61
0.73

10.20
10.80
11.40
12.00
12.70

0.39
0.48
0.58
0.69
0.82

11.30
11.80
12.40
13.00
13.60

40RM
40RMQ
40RMS
008

1000
1200
1400
1600
1800

5.63
6.76
7.89
9.01
10.10

0.22
0.32
0.46
0.62
0.80

7.61
8.49
9.42
10.40
11.40

0.30
0.41
0.55
0.71
0.90

9.11
9.88
10.70
11.60
12.50

0.38
0.50
0.64
0.80
0.10

10.40
11.10
11.80
12.60
13.50

0.45
0.57
0.72
0.89
1.09

40RMS
010

1200
1400
1600
1800
2000

6.58
7.67
8.77
9.86
11.00

0.31
0.44
0.60
0.78
0.99

8.35
9.25
10.20
11.10
12.10

0.40
0.54
0.70
0.88
1.09

9.76
10.60
11.40
12.30
13.20

0.49
0.63
0.79
0.98
1.19

11.00
11.70
12.50
13.30
14.10

40RM
40RMS
012

1450
1670
1900
2120
2350

7.58
8.73
9.93
11.10
12.30

0.46
0.63
0.84
1.08
1.36

9.18
10.20
11.20
12.20
13.30

0.56
0.73
0.95
1.18
1.17

10.50
11.40
12.30
13.30
14.30

0.65
0.83
1.05
1.29
1.57

40RMQ
012

1450
1670
1900
2120
2350

8.04
9.26
10.50
11.80
13.00

0.49
0.67
0.89
1.14
1.43

9.57
10.60
11.80
12.90
14.00

0.58
0.77
0.99
1.24
1.54

10.90
11.80
12.80
13.90
15.00

40RM
40RMS
014

1750
2050
2350
2650
2950

5.99
7.01
8.04
9.07
10.10

0.27
0.41
0.60
0.84
1.13

7.88
8.68
9.53
10.40
11.30

0.43
0.60
0.81
1.06
1.37

40RM
40RMS
016

2100
2450
2800
3150
3500

6.43
7.51
8.58
9.65
10.70

0.37
0.57
0.82
1.14
1.52

8.19
9.06
9.96
10.90
11.90

40RMQ
016

2100
2450
2800
3150
3500

6.65
7.76
8.87
9.98
11.10

0.39
0.60
0.86
1.19
1.59

40RM
40RMS
024

2900
3350
3800
4250
4700

8.58
9.91
11.30
12.60
13.90

40RM
40RMS
028

3500
4100
4700
5300
5900

40RM
40RMS
034

4250
4950
5650
6350
7050

250

300

r/s

kW

r/s

kW

0.46
0.55
0.66
0.77
0.91

12.30
12.80
13.40
13.90
14.50

0.53
0.63
0.73
0.85
0.99

13.30
13.70
14.20
14.80
15.40

0.60
0.70
0.81
0.93
1.07

11.50
12.10
12.80
13.60
14.40

0.53
0.66
0.81
0.98
1.18

12.50
13.10
13.80
14.50
15.20

0.61
0.74
0.89
1.07
1.27

13.40
14.00
14.60
15.30
16.00

0.68
0.82
0.97
1.16
1.36

0.57
0.71
0.88
1.07
1.29

12.00
12.70
13.40
14.20
15.00

0.65
0.80
0.97
1.16
3.38

13.00
13.60
14.30
15.10
15.80

0.73
0.88
1.05
1.25
1.48

13.90
14.50
15.20
15.90
16.60

0.81
0.96
1.14
1.34
1.57

11.60
12.50
13.30
14.20
15.20

0.73
0.92
1.14
1.39
1.68

12.70
13.40
14.30
15.10
16.00

0.82
1.01
1.24
1.48
1.78

13.60
14.30
15.10
15.90
16.80

0.90
1.10
1.33
1.58
1.88

14.50
15.20
15.90
16.70
17.60

0.99
1.18
1.42
1.68
1.98

0.67
0.86
1.09
1.35
1.65

12.00
12.90
13.80
14.80
15.80

0.76
0.95
1.19
1.45
1.75

13.00
13.80
14.70
15.60
16.60

0.85
1.04
1.28
1.55
1.85

13.90
14.70
15.60
16.40
17.40

0.93
1.13
1.38
1.64
1.95

14.80
15.50
16.40
17.20
18.10

1.02
1.22
1.47
1.74
2.05

9.41
10.10
10.80
11.60
12.40

0.59
0.78
1.01
1.28
1.61

10.70
11.30
12.00
12.70
13.40

0.75
0.96
1.21
1.50
1.85

11.90
12.40
13.00
13.70
14.40

0.92
1.14
1.41
1.72
2.08

13.00
13.50
14.00
14.60
15.30

1.08
1.33
1.61
1.94
2.32

14.00
14.40
14.90
15.50
16.10

1.25
1.51
1.82
2.16
2.56

0.55
0.77
1.05
1.38
1.78

9.65
10.40
11.20
12.00
12.90

0.73
0.97
1.27
1.63
2.05

10.90
11.60
12.30
13.10
13.90

0.92
1.18
1.49
1.87
2.31

12.10
12.70
13.30
14.00
14.80

1.11
1.39
1.72
2.12
2.58

13.10
13.70
14.30
14.90
15.60

1.30
1.60
1.95
2.36
2.84

14.10
14.60
15.10
15.80
16.40

1.50
1.81
2.18
2.61
3.11

8.39
9.30
10.20
11.20
12.20

0.58
0.81
1.09
1.44
1.86

9.83
10.60
11.50
12.30
13.20

0.76
1.01
1.32
1.70
2.14

11.10
11.80
12.50
13.40
14.20

0.95
1.22
1.55
1.95
2.41

12.20
12.90
13.60
14.30
15.10

1.13
1.43
1.78
2.20
2.68

13.30
13.80
14.50
15.20
15.90

1.31
1.63
2.01
2.45
2.95

14.20
14.80
15.40
16.00
16.70

1.50
1.84
2.24
2.70
3.22

0.86
1.28
1.81
2.46
3.24

9.96
11.10
12.30
13.60
14.80

1.09
1.53
2.09
2.76
3.57

11.20
12.20
13.30
14.50
15.60

1.32
1.79
2.37
3.07
3.90

12.30
13.20
14.30
15.30
16.40

1.55
2.04
2.64
3.37
4.22

13.30
14.20
15.10
16.10
17.20

1.78
2.30
2.93
3.67
4.55

14.20
15.10
16.00
16.90
17.90

2.01
2.55
3.21
3.98
4.88

15.10
15.90
16.80
17.70
18.60

2.25
2.81
3.49
4.28
5.21

6.79
7.95
9.12
10.30
11.40

0.84
1.29
1.88
2.62
3.52

8.14
9.12
10.10
11.20
12.30

1.12
1.60
2.21
3.00
3.90

9.42
10.20
11.10
12.10
13.10

1.47
1.96
2.59
3.37
4.32

10.70
11.30
12.10
12.90
13.90

1.89
2.38
3.02
3.81
4.77

11.80
12.40
13.00
13.80
14.60

2.39
2.86
3.49
4.29
5.26

12.90
13.40
13.90
14.60
15.40

2.96
3.40
4.02
4.82
5.79

14.00
14.30
14.80
15.40
16.10

3.61
4.00
4.60
5.38
6.35

7.86
9.15
10.40
11.70
13.00

1.33
2.03
2.92
4.02
5.37

8.99
10.10
11.30
12.50
13.70

1.63
2.35
3.27
4.40
5.77

10.10
11.10
12.20
13.30
14.40

1.97
2.72
3.66
4.81
6.21

11.10
12.00
13.00
14.00
15.10

2.37
3.12
4.08
5.25
6.66

12.20
12.90
13.80
14.70
15.70

2.83
3.58
4.54
5.72
7.15

13.20
13.80
14.60
15.50
16.40

3.34
4.08
5.04
6.23
7.67

14.10
14.70
15.40
16.20
17.10

3.92
4.62
5.57
6.77
8.21

See Legend and Notes on page 41.

39

Performance data (cont)


FAN PERFORMANCE DATA 350-600 Pa ESP 50 Hz, SI
UNIT

AIRFLOW
(L/s)

350

400

EXTERNAL STATIC PRESSURE (Pa)


450
500
r/s
kW
r/s
kW

r/s

kW

r/s

kW

40RM
007

850
1000
1150
1300
1450

14.10
14.60
15.10
15.60
16.10

0.67
0.77
0.88
1.01
1.15

15.00
15.40
15.90
16.40
16.90

0.74
0.84
0.96
1.09
1.24

15.70
16.10
16.60
17.10
17.60

0.81
0.91
1.03
1.17
1.32

16.50
16.90
17.30
17.80
18.30

40RM
40RMQ
40RMS
008

1000
1200
1400
1600
1800

14.30
14.80
15.40
16.10
16.80

0.76
0.90
1.06
1.24
1.45

15.10
15.60
16.20
16.80
17.50

0.83
0.98
1.14
1.33
1.54

15.80
16.40
16.90
17.50
18.20

0.91
1.05
1.22
1.41
1.63

40RMS
010

1200
1400
1600
1800
2000

14.70
15.30
16.00
16.60
17.30

0.89
1.05
1.23
1.43
1.66

15.50
16.10
16.70
17.40
18.00

0.97
1.13
1.31
1.52
1.76

16.30
16.80
17.40
18.10
18.70

40RM
40RMS
012

1450
1670
1900
2120
2350

15.30
16.00
16.70
17.50
18.30

1.07
1.27
1.51
1.77
2.07

16.10
16.70
17.40
18.20
19.00

1.15
1.36
1.60
1.86
2.17

40RMQ
012

1450
1670
1900
2120
2350

15.60
16.30
17.10
17.90
18.80

1.10
1.31
1.56
1.83
2.15

16.30
17.00
17.80
18.60
19.50

40RM
40RMS
014

1750
2050
2350
2650
2950

14.90
15.30
15.80
16.30
16.90

1.42
1.70
2.02
2.39
2.80

40RM
40RMS
016

2100
2450
2800
3150
3500

15.00
15.50
16.00
16.60
17.20

40RMQ
016

2100
2450
2800
3150
3500

40RM
40RMS
024

550

600

r/s

kW

r/s

kW

0.87
0.98
1.11
1.25
1.40

17.20
17.60
18.00
18.40
18.90

0.94
1.06
1.18
1.32
1.48

16.60
17.10
17.60
18.20
18.90

0.99
1.13
1.30
1.50
1.72

17.30
17.80
18.30
18.90
19.50

1.06
1.21
1.39
1.58
1.80

1.05
1.21
1.40
1.61
1.85

17.00
17.50
18.10
18.70
19.40

1.12
1.29
1.48
1.70
1.94

17.70
18.20
18.80
19.40

1.20
1.37
1.57
1.79

16.80
17.40
18.10
18.80
19.60

1.24
1.44
1.69
1.96
2.27

17.50
18.10
18.80
19.50

1.32
1.53
1.78
2.05

18.20
18.80
19.40

1.40
1.62
1.87

18.80
19.40

1.48
1.70

1.18
1.40
1.65
1.93
2.25

17.10
17.80
18.50
19.30

1.27
1.48
1.74
2.02

17.80
18.40
19.20
19.90

1.35
1.57
1.83
2.11

18.40
19.10
19.80

1.43
1.66
1.92

19.10
19.70

1.52
1.74

15.80
16.20
16.60
17.10
17.70

1.58
1.88
2.22
2.61
3.04

16.60
17.00
17.40
17.90
18.40

1.75
2.07
2.43
2.83
3.28

17.40
17.80
18.20
18.60
19.10

1.93
2.26
2.64
3.06
3.53

18.20
18.50
18.90
19.30
19.80

2.10
2.45
2.84
3.28
3.77

1.70
2.03
2.42
2.87
3.38

15.80
16.30
16.80
17.40
18.00

1.90
2.25
2.66
3.12
3.65

16.70
17.10
17.60
18.10
18.70

2.11
2.47
2.90
3.38
3.93

17.40
17.80
18.30
18.80
19.40

2.32
2.70
3.14
3.64
4.20

18.20
18.60
19.00
19.50

2.53
2.93
3.38
3.90

18.90
19.30
19.70

2.74
3.16
3.63

15.10
15.60
16.20
16.80
17.50

1.68
2.05
2.47
2.95
3.49

16.00
16.40
17.00
17.60
18.20

1.87
2.25
2.69
3.19
3.76

16.80
17.20
17.80
18.30
19.00

2.06
2.46
2.92
3.44
4.03

17.50
18.00
18.50
19.00
19.60

2.24
2.67
3.15
3.69
4.30

18.30
18.70
19.20
19.70

2.43
2.88
3.38
3.94

19.00
19.40
19.80

2.62
3.09
3.61

2900
3350
3800
4250
4700

16.00
16.70
17.50
18.40
19.30

2.49
3.08
3.77
4.59
5.54

16.80
17.50
18.20
19.10
20.00

2.73
3.34
4.06
4.90
5.87

17.50
18.20
18.90
19.80

2.97
3.61
4.35
5.21

18.30
18.90
19.60

3.22
3.87
4.64

19.00
19.60

3.47
4.14

19.70

3.72

40RM
40RMS
028

3500
4100
4700
5300
5900

15.10
15.30
15.70
16.20
16.90

4.33
4.67
5.23
5.99
6.95

16.10
16.20
16.50
17.00
17.60

5.12
5.39
5.91
6.65
7.59

17.10
17.10
17.40
17.80
18.30

5.98
6.18
6.64
7.35
8.27

18.00
18.00
18.20

6.92
7.02
7.43

40RM
40RMS
034

4250
4950
5650
6350
7050

15.00
15.50
16.10
16.90
17.70

4.55
5.22
6.16
7.34
8.79

16.00
16.30
16.90
17.50
18.30

5.24
5.86
6.77
7.94
9.39

16.80
17.10
17.60
18.20

5.99
6.56
7.43
8.58

17.70
17.90
18.30

6.79
7.30
8.13

See Legend and Notes on page 41.

40

ESP -

LEGEND
External Static Pressure

Bold indicates field-supplied drive is required.


Plain type indicates standard motor and standard drive.
Underline indicates a different motor and drive combination other than
the standard motor and standard drive combination is required. Refer to
fan motor and drive tables, pages 56-63, to complete the selection.
NOTES:
1. Maximum allowable fan speed is 18.3 r/s for unit sizes 028 and 034;
20 r/s for all other sizes.
2. Fan performance is based on deductions for wet coil, clean 25.4 mm
filters, and unit casing. See table below for factory-supplied filter pressure drop.
3. For 60 Hz units, the medium-static drive and standard motor combination is not available for 028 size. For 50 Hz units, the mediumstatic drive and standard motor combination is not available for
016-028 sizes. Use alternate motor if medium-static drive is required
for these sizes.

FACTOR Y-SUPPLIED FILTER PRESSURE DROP - SI


AIRFLOW
(L/s)
850
1150
1450

PRESSURE DROP
(Pa)
13
20
28

40RM
40RMQ
40RMS
008

1000
1400
1800

17
27
38

40RMS
010

1200
1600
2000

21
32
45

1450
1900
2350

28
42
56

1750
2350
2950

15
24
33

2100
2800
3500

20
30
42

2900
3800
4700
3500
4700
5900
4250
5650
7050

32
47
64
36
55
76
47
71
98

UNIT
40RM
007

40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

41

Performance data (cont)


ACCESSORY PLENUM AIR THROW DATA ENGLISH
(Ft)
VANE DEFLECTION
Straight
2112
45

UNIT

AIRFLOW
(Cfm)

40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

2,400

39

33

24

3,000

45

38

28

3,400

49

41

30

4,000

55

46

33

5,000

45

38

28

6,000

50

43

31

8,000

60

51

37

10,000

76

65

47

12,000

85

72

52

NOTE: Throw distances shown are for 75 fpm terminal velocity. Use
the following multipliers to determine throw values for other terminal
velocities.
TERMINAL VELOCITY
(Fpm)
50
100
150

42

THROW FACTOR
X
X
X

1.50
0.75
0.50

ACCESSORY PLENUM AIR THROW DATA SI


(m)
VANE DEFLECTION
Straight
2112
45

UNIT

AIRFLOW
(L/s)

40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

1150

11.71

9.91

7.20

1400

13.87

11.71

8.63

1600

14.98

12.53

9.17

1900

16.65

13.93

9.99

2350

13.77

11.63

8.57

2800

15.41

13.25

9.55

3800

18.17

15.44

11.20

4700

23.26

19.89

14.38

5650

25.97

22.00

15.89

NOTE: Throw distances shown are for 0.381 m/sec terminal velocity.
Use the following multipliers to determine throw values for other terminal velocities.
TERMINAL VELOCITY
(m/sec)
0.254
0.508
0.762

THROW FACTOR
X
X
X

1.50
0.75
0.50

ACCESSORY PRESSURE DROP ENGLISH


(in. wg)
HEATING COILS
Steam
0.10
0.16
0.23

UNIT

AIRFLOW
(Cfm)

DISCHARGE
PLENUM

RETURN AIR
GRILLE

40RM
007

1,800
2,400
3,000

0.06
0.10
0.14

0.01
0.01
0.02

Hot Water
0.10
0.16
0.23

40RM
40RMQ
40RMS
008

2,250
3,000
3,750

0.09
0.14
0.21

0.01
0.02
0.03

0.15
0.23
0.35

0.15
0.23
0.35

0.06
0.10
0.15

0.06
0.09
0.15

40RMS
010

2,550
3,400
4,250

0.11
0.17
0.24

0.02
0.03
0.04

0.18
0.28
0.41

0.18
0.28
0.41

0.07
0.12
0.19

0.07
0.13
0.19

40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

3,000
4,000
5,000

0.14
0.22
0.32

0.02
0.04
0.06

0.23
0.37
0.53

0.23
0.37
0.53

0.10
0.17
0.26

0.09
0.17
0.28

3,750
5,000
6,250

0.07
0.12
0.17

0.01
0.02
0.02

0.11
0.17
0.25

0.11
0.17
0.25

0.04
0.07
0.11

0.05
0.07
0.11

4,500
6,000
7,500

0.10
0.16
0.23

0.01
0.02
0.03

0.15
0.23
0.33

0.15
0.23
0.33

0.06
0.10
0.15

0.06
0.09
0.15

6,000
8,000
10,000
7,500
10,000
12,500
9,000
12,000
15,000

0.16
0.26
0.37
0.15
0.24
0.34
0.20
0.32
0.46

0.02
0.04
0.06
0.02
0.03
0.05
0.03
0.05
0.07

0.23
0.37
0.53
0.28
0.44
0.63
0.37
0.59
0.85

0.23
0.37
0.53
0.28
0.44
0.63
0.37
0.59
0.85

0.10
0.17
0.26
0.09
0.16
0.24
0.13
0.22
0.34

0.09
0.17
0.28
0.06
0.09
0.14
0.08
0.14
0.21

Electric
0.04
0.06
0.10

ECONOMIZER
0.05
0.07
0.09

ACCESSORY PRESSURE DROP SI


(Pa)
HEATING COILS
Steam
25
41
60

UNIT

AIRFLOW
(L/s)

DISCHARGE
PLENUM

RETURN AIR
GRILLE

40RM
007

850
1150
1450

15
25
36

2
3
5

Hot Water
25
41
60

40RM
40RMQ
40RMS
008

1000
1400
1800

20
34
51

2
5
8

33
57
85

33
57
85

12
24
39

13
22
39

40RMS
010

1200
1600
2000

26
42
61

5
7
10

44
70
101

44
70
101

18
31
48

17
32
47

40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034

1450
1900
2350

36
56
79

5
10
15

60
93
132

60
93
132

26
43
65

23
43
69

1750
2350
2950

18
29
43

2
5
5

26
43
62

26
43
62

10
17
26

12
17
27

2100
2800
3500

24
39
56

2
5
7

36
57
82

36
57
82

14
24
37

15
22
37

2900
3800
4700
3500
4700
5900
4250
5650
7050

41
64
91
37
59
86
50
80
114

5
10
15
5
7
12
7
12
17

60
93
132
67
109
157
92
147
210

60
93
132
67
109
157
92
147
210

26
43
65
22
39
60
32
56
85

23
43
69
15
22
35
20
35
52

Electric
9
16
26

ECONOMIZER
12
18
23

43

Electrical data
STANDARD MOTORS
FAN MOTOR
UNIT

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

V*-PH-Hz

VOLTAGE
LIMITS

Hp (kW)

FLA

208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50

187-253
187-253
414-506
518-632
207-253
360-440
187-253
187-253
414-506
518-632
207-253
360-440
187-253
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440

1.3 (0.97)
2.4 (1.79)
2.4 (1.79)
1.0 (0.75)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.0 (1.49)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.0 (1.49)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.0 (1.49)
2.9 (2.16)
2.9 (2.16)
2.9 (2.16)
2.9 (2.16)
3.0 (2.24)
2.9 (2.16)
2.9 (2.16)
3.7 (2.76)
3.7 (2.76)
3.0 (2.24)
2.9 (2.16)
2.9 (2.16)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)

7.6
5.2
2.6
1.4
5.2
2.6
11.0
5.2
2.6
2.3
5.2
2.6
11.0
5.2
2.6
2.3
5.2
2.6
5.2
2.6
2.3
7.5
3.4
7.5
3.4
3.8
7.5
3.4
10.2
4.8
3.8
7.5
3.4
15.3/12.8
6.4
5.1
15.2
7.6
22.4/19.4
9.7
7.8
22.8
11.4
29.3/26.8
13.4
10.3
32.2
16.1

See Legend and Notes on page 43.

44

POWER SUPPLY
Minimum
Circuit
MOCP
Amps
9.5
15
6.5
15
3.3
15
8.0
15
6.5
15
3.3
15
13.8
20
6.5
15
3.3
15
2.9
15
6.5
15
3.3
15
13.8
20
6.5
15
3.3
15
2.9
15
6.5
15
3.3
15
6.5
20
3.3
15
2.9
15
9.4
15
4.3
15
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
12.8
20
6.0
15
4.8
15
9.4
15
4.3
15
19.1/16.0
30/25
8.0
15
6.4
15
19.0
30
9.5
15
28.0/24.3
50/40
12.1
20
9.8
15
28.5
50
14.3
25
36.6/33.5
60/60
16.8
30
12.9
20
40.3
70
20.1
30

ALTERNATE MOTORS
FAN MOTOR
UNIT

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

V*-PH-Hz

VOLTAGE
LIMITS

Hp (kW)

FLA

208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50

187-253
187-253
414-506
518-632
207-253
360-440
187-253
187-253
414-506
518-632
207-253
360-440
187-253
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440
187-253
414-506
518-632
207-253
360-440

2.4 (1.79)
2.9 (2.16)
2.9 (2.16)
2.0 (1.49)
2.4 (1.79)
2.4 (1.79)
2.4 (1.79)
2.9 (2.16)
2.9 (2.16)
3.0 (2.24)
2.9 (2.16)
2.9 (2.16)
2.4 (1.79)
2.9 (2.16)
2.9 (2.16)
3.0 (2.24)
2.9 (2.16)
2.9 (2.16)
3.7 (2.76)
3.7 (2.76)
3.0 (2.24)
5.0 (3.73)
5.0 (3.73)
3.7 (2.76)
3.7 (2.76)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
5.0 (3.73)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
7.5 (5.59)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)
10.0 (7.46)

11.0
7.5
3.4
2.3
5.2
2.6
11.0
7.5
3.4
3.8
7.5
3.4
11.0
7.5
3.4
3.8
7.5
3.4
10.2
4.8
3.8
15.2
7.6
10.2
4.8
5.1
15.2
7.6
15.3/12.8
6.4
5.1
15.2
7.6
22.4/19.4
9.7
7.8
22.8
11.4
29.3/26.8
13.4
10.3
32.2
16.1

LEGEND
FLA
Full Load Amps
MOCP Maximum Overcurrent Protection
*Motors are designed for satisfactory operation within 10% of nominal voltages
shown. Voltages should not exceed the limits shown in the Voltage Limits column.
NOTES:
1. Minimum circuit amps (MCA) and MOCP values are calculated in accordance
with NEC (National Electrical Code) (U.S.A. standard), Article 440.
2. Motor FLA values are established in accordance with UL (Underwriters Laboratories) Standard 1995 (U.S.A. standard).
3. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater
than 2%. Use the following formula to determine the percentage of voltage
imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
EXAMPLE: Supply voltage is 400-3-50.
AB = 393 v
BC = 403 v
AC = 396 v
393 + 403 + 396
Average Voltage =
3
1192
=
3
= 397

POWER SUPPLY
Minimum
Circuit
MOCP
Amps
13.8
20
9.4
15
4.3
15
2.9
15
6.5
15
3.3
15
13.8
15
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
13.8
20
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
12.8
20
6.0
15
4.8
15
19.0
30
9.5
15
12.7
20
6.0
15
6.4
15
19.0
30
9.5
15
19.1/16.0
30/25
8.0
15
6.4
15
19.0
30
9.5
15
28.0/24.3
50/40
12.1
20
9.8
15
28.5
50
14.3
25
36.6/33.5
60/60
16.8
30
12.9
20
40.3
60
20.1
30

Determine maximum deviation from average voltage.


(AB) 397 393 = 4 v
(BC) 403 397 = 6 v
(AC) 397 396 = 1 v
Maximum deviation is 6 v.
Determine percent voltage imbalance.
6
% Voltage Imbalance = 100 x
397
= 1.5%
This amount of phase imbalance is satisfactory because it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

45

Electrical data (cont)


ELECTRIC HEATER DATA
HEATER
PART NO.

UNIT

V-PH-Hz

208-3-60

CAELHEAT001A00
240-3-60

240-3-50

480-3-60
CAELHEAT002A00
400-3-50

CAELHEAT003A00

575-3-60

208-3-60

CAELHEAT004A00
240-3-60
40RM007-012
40RMQ008-012
40RMS008-012

240-3-50

480-3-60
CAELHEAT005A00
400-3-50

CAELHEAT006A00

575-3-60

208-3-60

CAELHEAT007A00
240-3-60

240-3-50

480-3-60
CAELHEAT008A00
400-3-50

CAELHEAT009A00

46

575-3-60

FAN MOTOR
Hp
1.3
2.4
2.4
2.9
3.7
1.3
2.4
2.4
2.9
3.7
2.4
2.9
5.0
2.4
2.9
3.7
2.4
2.9
5.0
1.0
2.0
3.0
1.3
2.4
2.4
2.9
3.7
1.3
2.4
2.4
2.9
3.7
2.4
2.9
5.0
2.4
2.9
3.7
2.4
2.9
5.0
1.0
2.0
3.0
1.3
2.4
2.4
2.9
3.7
1.3
2.4
2.4
2.9
3.7
2.4
2.9
5.0
2.4
2.9
3.7
2.4
2.9
5.0
1.0
2.0
3.0

kW
0.97
1.79
1.79
2.16
2.76
0.97
1.79
1.79
2.16
2.76
1.79
2.16
3.73
1.79
2.16
2.76
1.79
2.16
3.73
0.75
1.49
2.24
0.97
1.79
1.79
2.16
2.76
0.97
1.79
1.79
2.16
2.76
1.79
2.16
3.73
1.79
2.16
2.76
1.79
2.16
3.73
0.75
1.49
2.24
0.97
1.79
1.79
2.16
2.76
0.97
1.79
1.79
2.16
2.76
1.79
2.16
3.73
1.79
2.16
2.76
1.79
2.16
3.73
0.75
1.49
2.24

FLA
7.6
11.0
5.2
7.5
10.2
7.6
11.0
5.2
7.5
10.2
5.2
7.5
15.2
2.6
3.4
4.8
2.6
3.4
7.6
1.4
2.3
3.8
7.6
11.0
5.2
7.5
10.2
7.6
11.0
5.2
7.5
10.2
5.2
7.5
15.2
2.6
3.4
4.8
2.6
3.4
7.6
1.4
2.3
3.8
7.6
11.0
5.2
7.5
10.2
7.6
11.0
5.2
7.5
10.2
5.2
7.5
15.2
2.6
3.4
4.8
2.6
3.4
7.6
1.4
2.3
3.8

Nominal
Capacity (kW)
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

ELECTRIC HEATER(S)
Actual Capacity (kW)
Stage 1
Stage 2
Total
3.8

3.8
3.8

3.8
3.8

3.8
3.8

3.8
3.8

3.8
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
5.0

5.0
3.5

3.5
3.5

3.5
3.5

3.5
5.0

5.0
5.0

5.0
5.0

5.0
7.5

7.5
7.5

7.5
7.5

7.5
7.5

7.5
7.5

7.5
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
6.9

6.9
6.9

6.9
6.9

6.9
10.0

10.0
10.0

10.0
10.0

10.0
11.3

11.3
11.3

11.3
11.3

11.3
11.3

11.3
11.3

11.3
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
10.4

10.4
10.4

10.4
10.4

10.4
15.0

15.0
15.0

15.0
15.0

15.0

FLA
10.4
10.4
10.4
10.4
10.4
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
6.00
6.00
6.00
5.00
5.00
5.00
5.00
5.00
5.00
20.8
20.8
20.8
20.8
20.8
24.1
24.1
24.1
24.1
24.1
24.1
24.1
24.1
12.0
12.0
12.0
10.0
10.0
10.0
10.0
10.0
10.0
31.3
31.3
31.3
31.3
31.3
36.1
36.1
36.1
36.1
36.1
36.1
36.1
36.1
18.0
18.0
18.0
15.0
15.0
15.0
15.1
15.1
15.1

MCA*

MOCP*

22.5
26.8
19.5
22.4
25.8
24.5
28.8
21.5
24.4
27.8
21.5
24.4
34.0
10.8
11.8
13.5
9.5
10.5
15.8
8.0
9.2
11.0
35.6
39.8
32.6
35.4
38.8
39.6
43.8
36.6
39.4
42.8
36.6
39.4
49.1
18.3
19.3
21.0
15.8
16.8
22.0
14.3
15.4
17.3
48.6
52.9
45.6
48.5
51.9
54.6
58.9
51.6
54.5
57.9
51.6
54.5
64.1
25.8
26.8
28.6
22.0
23.0
28.3
20.6
21.7
23.6

25
35
20
25
30
25
35
25
25
30
25
25
40
15
15
15
15
15
20
15
15
15
40
40
35
40
40
40
50
40
40
50
40
40
50
20
20
25
20
20
25
15
20
20
50
60
50
50
60
60
60
60
60
60
60
60
70
30
30
30
25
25
30
25
25
25

ELECTRIC HEATER DATA (cont)


HEATER
PART NO.

UNIT

V-PH-Hz

208-3-60

CAELHEAT010A00
240-3-60
40RM007-012
40RMQ008-012
40RMS008-012

240-3-50

480-3-60
CAELHEAT011A00
400-3-50

CAELHEAT012A00

575-3-60

208-3-60

CAELHEAT013A00

240-3-60
40RM008,012
40RMQ008,012
40RMS008-012

240-3-50

480-3-60
CAELHEAT014A00
400-3-50
CAELHEAT015A00

FLA
Hp
MCA
MOCP

575-3-60

FAN MOTOR
Hp
1.3
2.4
2.4
2.9
3.7
1.3
2.4
2.4
2.9
3.7
2.4
2.9
5.0
2.4
2.9
3.7
2.4
2.9
5.0
1.0
2.0
3.0
2.4
2.4
2.9
3.7
2.4
2.4
2.9
3.7
2.4
2.9
5.0
2.4
2.9
3.7
2.4
2.9
5.0
2.0
3.0

kW
0.97
1.79
1.79
2.16
2.76
0.97
1.79
1.79
2.16
2.76
1.79
2.16
3.73
1.79
2.16
2.76
1.79
2.16
3.73
0.75
1.49
2.24
1.79
1.79
2.16
2.76
1.79
1.79
2.16
2.76
1.79
2.16
3.73
1.79
2.16
2.76
1.79
2.16
3.73
1.49
2.24

FLA
7.6
11.0
5.2
7.5
10.2
7.6
11.0
5.2
7.5
10.2
5.2
7.5
15.2
2.6
3.4
4.8
2.6
3.4
7.6
1.4
2.3
3.8
11.0
5.2
7.5
10.2
11.0
5.2
7.5
10.2
5.2
7.5
15.2
2.6
3.4
4.8
2.6
3.4
7.6
2.3
3.8

LEGEND
Full Load Amps
Horsepower
Minimum Circuit Amps
Maximum Overcurrent Protection (Amps)

*Values shown are for single-point connection of electric heat accessory and air
handler.
Single-phase motors. All other motors are 3-phase.

Nominal
Capacity (kW)
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35

ELECTRIC HEATER(S)
Actual Capacity (kW)
Stage 1
Stage 2
Total
11.3
7.5
18.8
11.3
7.5
18.8
11.3
7.5
18.8
11.3
7.5
18.8
11.3
7.5
18.8
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
10.4
6.9
17.4
10.4
6.9
17.4
10.4
6.9
17.4
15.0
10.0
25.0
15.0
10.0
25.0
15.0
10.0
25.0
15.0
11.3
26.3
15.0
11.3
26.3
15.0
11.3
26.3
15.0
11.3
26.3
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
20.0
15.0
35.0
13.9
10.4
24.3
13.9
10.4
24.3
13.9
10.4
24.3
20.0
15.0
35.0
20.0
15.0
35.0

FLA
52.1
52.1
52.1
52.1
52.1
60.1
60.1
60.1
60.1
60.1
60.1
60.1
60.1
30.1
30.1
30.1
25.1
25.1
25.1
25.1
25.1
25.1
73.0
73.0
73.0
73.0
84.2
84.2
84.2
84.2
84.2
84.2
84.2
42.1
42.1
42.1
35.1
35.1
35.1
35.1
35.1

MCA*

MOCP*

74.7
78.9
71.7
74.5
77.9
84.7
88.9
81.7
84.6
87.9
81.7
84.6
94.2
40.8
41.8
43.6
34.6
35.6
40.8
33.1
34.3
36.1
105.0
97.7
100.6
104.0
119.0
111.7
114.6
118.0
111.7
114.6
124.2
55.9
56.9
58.6
47.1
48.1
53.4
46.8
48.7

80
80
80
80
80
90
90
90
90
90
90
90
100
50
50
50
25
40
50
35
35
40
110
100
110
110
125
125
125
125
125
125
125
60
60
60
50
50
60
50
50

2. The following equation converts kW of heat energy to Btuh:


kW x 3,412 = Btuh.
3. Heater contactor coils are 24 v and require 8 va holding current.
4. Electric heaters are tested and ETL approved at maximum total external static
pressure of 1.9 in. wg.
5. MCA and MOCP values apply to both standard and alternate factory-supplied
motors.

NOTES:
1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine
heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage.
HEATER
ACTUAL HEATER VOLTAGE
RATING
200
208
230
240 400 440 460 480 550
VOLTAGE
240
0.694 0.751 0.918 1

480

0.694 0.84 0.918 1

575

0.915

575 600

1 1.089

47

Electrical data (cont)


ELECTRIC HEATER DATA (cont)
HEATER
PART NO.

UNIT

208-3-60

CAELHEAT016A00

240-3-60

240-3-50

480-3-60
CAELHEAT017A00
400-3-50

CAELHEAT018A00

575-3-60

208-3-60

CAELHEAT019A00

240-3-60

40RM014-024
40RMQ016
40RMS014-024

240-3-50

480-3-60
CAELHEAT020A00
400-3-50

CAELHEAT021A00

575-3-60

208-3-60

CAELHEAT022A00

240-3-60

240-3-50

480-3-60
CAELHEAT023A00
400-3-50

CAELHEAT024A00

48

FAN MOTOR

V-PH-Hz

575-3-60

Hp
2.9
3.7
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
3.0
5.0
7.5
2.9
3.7
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
3.0
5.0
7.5
2.9
3.7
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
2.9
3.7
5.0
7.5
2.9
5.0
7.5
3.0
5.0
7.5

kW
2.16
2.76
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.24
3.73
5.59
2.16
2.76
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.24
3.73
5.59
2.16
2.76
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.16
2.76
3.73
5.59
2.16
3.73
5.59
2.24
3.73
5.59

FLA
7.5
10.2
15.3
22.4
7.5
10.2
12.8
19.4
7.5
15.2
22.8
3.4
4.8
6.4
9.7
3.4
7.6
11.4
3.8
5.1
7.8
7.5
10.2
15.3
22.4
7.5
10.2
12.8
19.4
7.5
15.2
22.8
3.4
4.8
6.4
9.7
3.4
7.6
11.4
3.8
5.1
7.8
7.5
10.2
15.3
22.4
7.5
10.2
12.8
19.4
7.5
15.2
22.8
3.4
4.8
6.4
9.7
3.4
7.6
11.4
3.8
5.1
7.8

Nominal
Capacity (kW)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30

ELECTRIC HEATER(S)
Actual Capacity (kW)
Stage 1
Stage 2
Total
7.5

7.5
7.5

7.5
7.5

7.5
7.5

7.5
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
10.0

10.0
6.9

6.9
6.9

6.9
6.9

6.9
10.0

10.0
10.0

10.0
10.0

10.0
15.0

15.0
15.0

15.0
15.0

15.0
15.0

15.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
13.9

13.9
13.9

13.9
13.9

13.9
20.0

20.0
20.0

20.0
20.0

20.0
15.0
7.5
22.5
15.0
7.5
22.5
15.0
7.5
22.5
15.0
7.5
22.5
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0
13.9
6.9
20.8
13.9
7.9
20.8
13.9
7.9
20.8
20.0
10.0
30.0
20.0
10.0
30.0
20.0
10.0
30.0

FLA
20.8
20.8
20.8
20.8
24.1
24.1
24.1
24.1
24.1
24.1
24.1
12.0
12.0
12.0
12.0
10.0
10.0
10.0
10.0
10.0
10.0
41.7
41.7
41.7
41.7
48.1
48.1
48.1
48.1
48.1
48.1
48.1
24.1
24.1
24.1
24.1
20.0
20.0
20.0
20.1
20.1
20.1
62.5
62.5
62.5
62.5
72.2
72.2
72.2
72.2
72.2
72.2
72.2
36.1
36.1
36.1
36.1
30.1
30.1
30.1
30.1
30.1
30.1

MCA*

MOCP*

35.4
38.8
45.1
54.4
39.4
42.8
46.1
54.4
39.4
49.1
58.6
19.3
21.0
23.0
27.2
16.8
22.0
26.8
17.3
19.6
22.1
61.5
65.4
71.1
79.6
69.5
73.4
76.1
84.4
69.5
79.1
86.4
34.3
36.1
39.1
43.2
29.3
45.1
49.2
29.9
31.5
34.9
87.5
90.9
97.2
106.2
99.6
103.0
106.2
114.5
99.6
109.2
118.7
49.4
51.1
53.1
57.2
41.8
47.1
51.8
42.4
44.0
47.4

40
40
50
70
40
50
50
70
40
50
70
20
25
25
30
20
25
35
20
20
25
70
70
80
90
70
80
80
90
70
80
90
35
40
40
50
30
50
50
30
35
35
90
100
100
110
100
110
110
125
100
110
125
50
60
60
60
50
50
60
50
50
50

ELECTRIC HEATER DATA (cont)


HEATER
PART NO.

UNIT

V-PH-Hz

208-3-60

CAELHEAT025A00

240-3-60

40RM016,024
40RMQ016
40RMS016,024

240-3-50

480-3-60

CAELHEAT026A00
400-3-50

CAELHEAT027A00

575-3-60
208-3-60

CAELHEAT028A00

240-3-60
240-3-50
480-3-60

CAELHEAT029A00
400-3-50
CAELHEAT030A00

CAELHEAT031A00

40RM028,034
40RMS028,034

575-3-60
208-3-60
240-3-60
240-3-50
480-3-60

CAELHEAT032A00
400-3-50
CAELHEAT033A00

FLA
Hp
MCA
MOCP

575-3-60

FAN MOTOR
Hp
3.7
5.0
7.5
3.7
5.0
7.5
2.9
5.0
7.5
3.7
5.0
7.5
2.9
5.0
7.5
3.0
5.0
7.5
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0

kW
2.76
3.73
5.59
2.76
3.73
5.59
2.16
3.73
5.59
2.76
3.73
5.59
2.16
3.73
5.59
2.24
3.73
5.59
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46

FLA
10.2
15.3
22.4
10.2
12.8
19.4
7.5
15.2
22.8
4.8
6.4
9.7
3.4
7.6
11.4
3.8
5.1
7.8
22.4
29.3
19.4
26.8
22.8
32.2
9.7
13.4
11.4
16.1
7.8
10.3
22.4
29.3
19.4
26.8
22.8
32.2
9.7
13.4
11.4
16.1
7.8
10.3

LEGEND
Full Load Amps
Horsepower
Minimum Circuit Amps
Maximum Overcurrent Protection (Amps)

*Values shown are for single-point connection of electric heat accessory and air
handler.
Single-phase motors. All other motors are 3-phase.

Nominal
Capacity (kW)
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
20
20
20
20
20
20
20
20
20
20
20
20
40
40
40
40
40
40
40
40
40
40
40
40

ELECTRIC HEATER(S)
Actual Capacity (kW)
Stage 1
Stage 2
Total
22.6
15.0
37.6
22.6
15.0
37.6
22.6
15.0
37.6
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
20.8
13.9
34.7
20.8
13.9
34.7
20.8
13.9
34.7
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
15.0

15.0
15.0

15.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
20.0

20.0
13.9

13.9
13.9

13.9
20.0

20.0
20.0

20.0
15.0
15.0
30.0
15.0
15.0
30.0
20.0
20.0
40.0
20.0
20.0
40.0
20.0
20.0
40.0
20.0
20.0
40.0
20.0
20.0
40.0
20.0
20.0
40.0
13.9
13.9
27.8
13.9
13.9
27.8
20.0
20.0
40.0
20.0
20.0
40.0

FLA
104.3
104.3
104.3
120.3
120.3
120.3
120.3
120.3
120.3
60.1
60.1
60.1
50.1
50.1
50.1
50.2
50.2
50.2
41.7
41.7
48.1
48.1
48.1
48.1
24.1
24.1
20.0
20.0
20.1
20.1
83.4
83.4
96.2
96.2
96.2
96.2
48.1
48.1
40.1
40.1
40.2
40.2

MCA*

MOCP*

143.1
149.5
158.4
163.1
166.4
174.6
159.7
169.4
178.9
81.2
83.2
87.3
66.9
72.1
76.9
67.5
69.1
72.5
80.1
88.7
84.3
94.0
88.6
100.4
42.2
46.8
39.3
45.2
34.9
38.0
132.2
140.9
144.5
153.8
148.8
160.5
72.3
76.9
64.4
70.2
60.0
63.1

150
150
175
175
175
200
175
175
200
90
90
90
70
80
80
70
70
80
90
100
90
110
90
110
50
50
40
50
35
40
150
150
150
175
150
175
80
80
70
80
60
70

2. The following equation converts kW of heat energy to Btuh:


kW x 3,412 = Btuh.
3. Heater contactor coils are 24 v and require 8 va holding current.
4. Electric heaters are tested and ETL approved at maximum total external static
pressure of 1.9 in. wg.
5. MCA and MOCP values apply to both standard and alternate factory-supplied
motors.

NOTES:
1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine
heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage.
HEATER
ACTUAL HEATER VOLTAGE
RATING
VOLTAGE 200 208 230 240 400 440 460 480 550
240
0.694 0.751 0.918 1

480

0.694 0.84 0.918 1

575

0.915

575 600

1 1.089

49

Electrical data (cont)


ELECTRIC HEATER DATA (cont)
HEATER
PART NO.

UNIT

V-PH-Hz
208-3-60

CAELHEAT034A00

240-3-60
240-3-50
480-3-60

CAELHEAT035A00
400-3-50
CAELHEAT036A00

CAELHEAT037A00

40RM028,034
40RMS028,034

575-3-60
208-3-60
240-3-60
240-3-50
480-3-60

CAELHEAT038A00
400-3-50
CAELHEAT039A00

FLA
Hp
MCA
MOCP

575-3-60

FAN MOTOR
Hp
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0
7.5
10.0

kW
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46
5.59
7.46

FLA
22.4
29.3
19.4
26.8
22.8
32.2
9.7
13.4
11.4
16.1
7.8
10.3
22.4
29.3
19.4
26.8
22.8
32.2
9.7
13.4
11.4
16.1
7.8
10.3

LEGEND
Full Load Amps
Horsepower
Minimum Circuit Amps
Maximum Overcurrent Protection (Amps)

*Values shown are for single-point connection of electric heat accessory and air
handler.
Single-phase motors. All other motors are 3-phase.
NOTES:
1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine
heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage.
HEATER
ACTUAL HEATER VOLTAGE
RATING
VOLTAGE 200 208 230 240 400 440 460 480 550 575 600
240
0.694 0.751 0.918 1
480
- 0.694 0.84 0.918 1
575
- 0.915 1 1.089

50

Nominal
Capacity (kW)
50
50
50
50
50
50
50
50
50
50
50
50
70
70
70
70
70
70
70
70
70
70
70
70

ELECTRIC HEATER(S)
Actual Capacity (kW)
Stage 1
Stage 2
Total
22.6
15.0
37.6
22.6
15.0
37.6
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
30.0
20.0
50.0
20.8
13.9
34.7
20.8
13.9
34.7
30.0
20.0
50.0
30.0
20.0
50.0
30.0
22.6
52.6
30.0
22.6
52.6
40.0
30.0
70.0
40.0
30.0
70.0
40.0
30.0
70.0
40.0
30.0
70.0
40.0
30.0
70.0
40.0
30.0
70.0
27.8
20.8
48.6
27.8
20.8
48.6
40.0
30.0
70.0
40.0
30.0
70.0

FLA
104.3
104.3
120.3
120.3
120.3
120.3
60.1
60.1
50.1
50.1
50.2
50.2
145.9
145.9
168.4
168.4
168.4
168.4
84.2
84.2
70.2
70.2
70.3
70.3

MCA*

MOCP*

158.3
166.9
174.6
183.9
178.9
190.6
87.3
91.9
76.9
82.8
72.5
75.6
173.9
182.6
192.6
201.9
196.9
208.6
96.3
100.9
84.4
90.3
80.0
83.2

175
175
200
200
200
200
90
100
80
90
80
80
175
200
200
225
200
225
100
110
90
100
90
90

2. The following equation converts kW of heat energy to Btuh:


kW x 3,412 = Btuh.
3. Heater contactor coils are 24 v and require 8 va holding current.
4. Electric heaters are tested and ETL approved at maximum total external static
pressure of 1.9 in. wg.
5. MCA and MOCP values apply to both standard and alternate factory-supplied
motors.

Typical piping and wiring


VERTICAL INST ALLA TION - 40RM (TYPICAL)

NEC TXV -

LEGEND
National Electrical Code
Thermostatic Expansion Valve
Piping

*Field supplied.
Double riser may be required. Consult condensing unit product data catalog for
details.

NOTES:
1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design
Manual for details.
2. All wiring must comply with the applicable local and national codes.
3. Wiring and piping shown are general points-of-connection guides only and are not intended
for, or to include all details for, a specific installation.
4. Liquid line solenoid valve (solenoid drop control) is recommended to prevent refrigerant
migration to the compressor.
5. Internal factory-supplied TXVs not shown.

51

Typical piping and wiring (cont)


HORIZONT AL INST ALLA TION - 40RM (TYPICAL)

NEC TXV -

LEGEND
National Electrical Code
Thermostatic Expansion Valve

*Accessory item.
Field supplied.
NOTES:
1. All piping must follow standard refrigerant piping techniqes. Refer
to Carrier System Design Manual for details.

52

2. All wiring must comply with the applicable local and national codes.
3. Wiring and piping shown are general points-of-connection guides
only and are not intended for, or to include all details for, a specific installation.
4. Liquid line solenoid valve (solenoid drop control) is recommended
to prevent refrigerant migration to the compressor.
5. Internal factory-supplied TXVs not shown.

WIRE ROUTING, BASE UNIT - 40RM, 40RMS

WIRE ROUTING, UNIT WITH ELECTRIC HEAT - 40RM, 40RMS

NEC -

National Electrical Code

53

Typical piping and wiring (cont)


CONTROL WIRING SCHEMA TIC - TYPICAL

EQUIP
GND
HC
HTR
IFC
IFM
TB

54

LEGEND
Equipment
Ground
Heater Contactor
Heater Element
Indoor Fan Contactor
Indoor Fan Motor
Terminal Block
Factory Wiring
Field Wiring

Application data
Operating limits
Maximum fan speed - 40RM007-024,
40RMQ, 40RMS008-024 . . . . . . . . . 1200 rpm (20 r/s)
Maximum fan speed - 40RM and
40RMS028,034 . . . . . . . . . . . . . . . . 1100 rpm (18.3 r/s)

General
Select equipment to match or to be slightly lessthan peak
load. This providesbetter humidity control, lessunit cycling,
and lesspart-load operation. Equipment should be selected
to perform at no lessthan 300 cfm/ton (40 L/s per kW).

The air handler fan must always be operating when the


condensingunit is operating.
Ductwork should be sized according to unit size, not
building load. For larger units with two fans, a split duct
transition is recommendedat the fan outlets, but a plenum
can be usedwith slight reduction in external static pressure
capability.
For variable air volume (VAV) systems with supply-toreturn air recycling, usethe equipment room as a return air
plenum.

FACTOR Y-INST ALLED NOZZLE AND DISTRIBUTOR DATA


UNIT

TXV
Qty...Part No.*

DISTRIBUTOR
Qty...Part No.*

40RM007
40RM008
40RMQ008
40RM012
40RMQ012
40RM014
40RM016
40RMQ016
40RM024
40RM028
40RM034

1...XVE-5
1...SVE-8
1...SVE-8
2...XVE-4
2...XVE-4
2...XVE-5
2...XVE-8
2...SVE-8
2...XVE-10
2...EBSVE-11
2...SVE-15

1...1116
1...1126
1...1657
2...1115
2...1655
2...1115
2...1116
2...1657
2...1116
2...1126
2...1126

FEEDER TUBES
PER DISTRIBUTOR
Qty...Size (in.)
12...1/4
15...1/4
15...1/4
9...1/4
9...1/4
9...1/4
12...1/4
16...1/4
13...1/4
15...1/4
18...1/4

NOZZLE
Qty...Part No.
1...E5
1...C6
1...C6
2...E4
2...E4
2...E5
2...E6
2...C6
2...E8
2...C10
2...C12

*Sporlan Valve Co. part numbers shown.


NOTE: Hot gas bypass applications require field-supplied auxiliary side connector.

55

Application data (cont)


FAN MOTOR DATA
STANDARD MOTOR -

UNIT

40RM
007

208/230-1-60
Speed (rpm)
1725
Hp
1.3
Frame (NEMA)
56Y
5/8
Shaft Dia (in.)
208/230-3-60 and 460-3-60
Speed (rpm)
1725
Hp
2.4
Frame (NEMA)
56Y
5/8
Shaft Dia (in.)
575-3-60
Speed (rpm)
1725
Hp
1.0
Frame (NEMA)
56
5/8
Shaft Dia (in.)
230-3-50 and 400-3-50
Speed (rpm)
1425
Hp
2.4
Frame (NEMA)
56Y
5/8
Shaft Dia (in.)
NEMA -

40RM
40RMQ
40RMS
012

ENGLISH

40RM
40RMQ
40RMS
008

40RMS
010

1725
2.4
56Y

1725
2.4
56Y

5/8

5/8

1725
2.4
56Y

1725
2.4
56Y

1725
2.4
56Y

1725
2.9
56Y

1725
3.7
56Y

5/8

5/8

5/8

7/8

7/8

1725
2.0
56HZ

1725
2.0
56HZ

1725
2.0
56HZ

1725
3.0
56HZ

1725
3.0
56HZ

7/8

7/8

7/8

7/8

7/8

1425
2.4
56Y

1425
2.4
56Y

1425
2.9
56Y

1425
2.9
56Y

1425
2.9
56Y

5/8

5/8

7/8

7/8

7/8

UNIT

40RM
007

208/230-1-60
Speed (rpm)
1725
Hp
2.4
Frame (NEMA)
56Y
5/8
Shaft Dia (in.)
208/230-3-60 and 460-3-60
Speed (rpm)
1725
Hp
2.9
Frame (NEMA)
56Y
7/8
Shaft Dia (in.)
575-3-60
Speed (rpm)
1725
Hp
2.0
Frame (NEMA)
56HZ
7/8
Shaft Dia (in.)
230-3-50 and 400-3-50
Speed (rpm)
1425
Hp
2.4
Frame (NEMA)
56Y
7/8
Shaft Dia (in.)

56

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034
-

1745
5.0
S184T
11/8

1745
7.5
S213T
13/8

1745
10.0
S215T
13/8

1745
5.0
184T
11/8

1755
7.5
S213T
13/8

1755
10.0
D215T
13/8

1425
5.0
184T
11/8

1425
7.5
S213T
13/8

1425
10.0
S215T
13/8

National Electrical Manufacturers Association (U.S.A.)

ALTERNA TE MOTOR -

NEMA -

40RM
40RMQ
40RMS
016

40RM
40RMS
014

40RM
40RMQ
40RMS
008

40RMS
010

1725
2.4
56Y

1725
2.4
56Y

7/8

7/8

1725
2.9
56Y

1725
2.9
56Y

1725
3.7
Y56Y

1725
3.7
Y56Y

7/8

7/8

7/8

7/8

1725
3.0
56HZ

1725
3.0
56HZ

1725
3.0
56HZ

7/8

7/8

7/8

1425
2.9
56Y

1425
2.9
56Y

1425
5.0
S184T

7/8

7/8

7/8

National Electrical Manufacturers Association (U.S.A.)

40RM
40RMQ
40RMS
012

ENGLISH

40RM
40RMS
014
-

40RM
40RMQ
40RMS
016
-

40RM
40RMS
024
-

40RM
40RMS
028
-

1725
5.0
S184T
11/8

1745
7.5
S213T
13/8

1745
10.0
S215T
13/8

1745
5.0
184T
11/8

1745
5.0
184T
11/8

1755
7.5
S213T
13/8

1750
10.0
D215T
13/8

1425
5.0
S184T
11/8

1425
5.0
S184T
11/8

1425
7.5
S213T
13/8

1425
10.0
S215T
13/8

FAN MOTOR DRIVE (cont)


STANDARD MOTOR -

UNIT

40RM
007

208/230-1-60
Speed (r/s)
28.75
Shaft kW
0.97
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
208/230-3-60 and 460-3-60
Speed (r/s)
28.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
575-3-60
Speed (r/s)
28.75
Shaft kW
0.75
Frame (NEMA)
56
Shaft Dia (mm)
15.9
230-3-50 and 400-3-50
Speed (r/s)
23.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
NEMA -

40RM
40RMQ
40RMS
012

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
016

28.75
1.79
56Y
15.9

28.75
1.79
56Y
15.9

28.75
1.79
56Y
15.9

28.75
1.79
56Y
15.9

28.75
1.79
56Y
15.9

28.75
2.16
56Y
22.2

28.75
2.76
56Y
22.2

29.08
3.73
S184T
28.6

29.08
5.60
S213T
34.9

29.08
7.46
S215T
34.9

28.75
1.49
56HZ
22.2

28.75
1.49
56HZ
22.2

28.75
1.49
56HZ
22.2

28.75
2.24
56HZ
22.2

28.75
2.24
56HZ
22.2

29.08
3.73
184T
28.6

29.25
5.60
S213T
34.9

29.25
7.46
S215T
34.9

23.75
1.79
56Y
15.9

23.75
1.79
56Y
15.9

23.75
2.16
56Y
22.2

23.75
2.16
56Y
22.2

23.75
2.16
56Y
22.2

23.75
3.73
184T
28.6

23.75
5.60
S213T
34.9

23.75
7.46
S215T
34.9

40RM
40RMS
014

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034
-

National Electrical Manufacturers Association (U.S.A.)

ALTERNA TE MOTOR -

UNIT

40RM
007

208/230-1-60
Speed (r/s)
28.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
208/230-3-60 and 460-3-60
Speed (r/s)
28.75
Shaft kW
2.16
Frame (NEMA)
56Y
Shaft Dia (mm)
22.2
575-3-60
Speed (r/s)
28.75
Shaft kW
1.50
Frame (NEMA)
56HZ
Shaft Dia (mm)
22.2
230-3-50 and 400-3-50
Speed (r/s)
23.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
22.2
NEMA -

SI

40RM
40RMQ
40RMS
012

SI

40RM
40RMQ
40RMS
008

40RMS
010

28.75
1.79
56Y
22.2

28.75
1.79
56Y
22.2

28.75
2.16
56Y
22.2

28.75
2.16
56Y
22.2

28.75
2.76
Y56Y
22.2

28.75
2.76
Y56Y
22.2

29.08
3.73
S184T
28.6

29.08
5.60
S213T
34.9

29.17
7.46
S215T
34.9

28.75
2.24
56HZ
22.2

28.75
2.24
56HZ
22.2

28.75
2.24
56HZ
22.2

29.08
3.73
184T
28.6

29.08
3.73
184T
28.6

29.25
5.60
S213T
34.9

29.17
7.46
D215T
34.9

23.75
2.16
56Y
22.2

23.75
2.16
56Y
22.2

23.75
3.73
S184T
22.2

23.75
3.73
S184T
28.6

23.75
3.73
S184T
28.6

23.75
5.60
S213T
34.9

23.75
7.46
S215T
34.9

40RM
40RMS
014
-

40RM
40RMQ
40RMS
016
-

40RM
40RMS
024
-

40RM
40RMS
028
-

National Electrical Manufacturers Association (U.S.A.)

57

Application data (cont)


STANDARD DRIVE DATA, 6 0 Hz - ENGLISH

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

2.4-3.4

2.8-3.8

2.8-3.8

3.4-4.4

2.8-3.8

2.8-3.8

3.7-4.7

4.3-5.3

4.3-5.3

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

8.8
1
1-A

8.8
1
1-A

8.8
1
1-A

8.8
1
1-A

9.0
1 7/16
1-A

9.0
1 7/16
1-A

9.4
1 7/16
2-B

40.3

41.3

41.3

42.3

42.3

42.3

41.8

11.0
1 15/16
2-B*
(2) 42.8
(2) 43.8

11.0
1 15/16
2-B*
(2) 42.8
(2) 43.8

568
470-666
1200

647
549-745
1200

647
549-745
1200

764
666-863
1200

632
537-728
1200

632
537-728
1200

771
679-863
1200

752
682-841
1100

752
674-831
1100

19.6

19.6

19.6

19.7

19.1

19.1

15.3

13.1

13.1

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

9.1210.99

6.679.43

6.679.43

*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.

MEDIUM-ST ATIC DRIVE DATA, 6 0 Hz - ENGLISH

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.7-4.7

4.3-5.3

4.3-5.3

4.3-5.3

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

3.0

8.8
1
1-A

8.0
1
1-A

8.0
1
1-A

8.0
1
1-A

8.2
1 7/16
1-A

8.6
1 7/16
1-B

9.4
1 7/16
2-B

42.3

40.3

40.3

40.3

41.3

41.8

41.8

9.4
1 15/16
2-B*
(2) 38.8
(2) 39.8

9.4
1 15/16
2-B*
(2) 38.8
(2) 39.8

764
666-863
1200

841
733-949
1200

841
733-949
1200

841
733-949
1200

820
715-926
1200

842
742-943
1200

881
798-984
1200

881
798-984
1100

881
798-984
1100

19.7

21.6

21.6

21.6

21.1

16.7

15.3

15.3

15.3

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

9.1610.99

6.679.43

6.679.43

*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.

58

HIGH-ST ATIC DRIVE DATA, 6 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

ENGLISH

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.7-4.7

4.3-5.3

4.3-5.3

4.3-5.3

4.3-5.3

2.5

2.5

2.5

2.5

3.0

3.0

3.0

3.0

3.0

7.0
1
1-A
41.3

6.0*
1
1-A
37.3

6.0
1
1-A
37.3

6.0
1
1-A
37.3

7.4
1 7/16
1-B
39.8

7.9
1 7/16
1-B
39.8

7.4
1 7/16
2-B
36.8

8.6
1 15/16
2-B
37.8

8.6
1 15/16
2-B
37.8

961
8381084
1200

1121
9781200*
1200

1121
9781200
1200

1121
9781200
1200

979
8731096
1200

1060
9501171
1200

1118
10141200
1200

1024
8731075
1100

1024
8731075
1100

24.6

28.7

28.7

28.7

19.4

18.4

19.4

16.7

16.7

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32**

9.1610.99

8.1610.02

6.679.43

6.679.43

*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 7 in.
and resulting fan speed is 837-1096 rpm.
It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 1200 rpm.
**575-v unit has a center distance of 9.16-10.99.

STANDARD DRIVE DATA, 5 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

ENGLISH

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

2.4-3.4

2.8-3.8

2.8-3.8

3.4-4.4

3.4-4.4

3.4-4.4

4.3-5.3

4.3-5.3

4.3-5.3

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

8.0
1
1-A
39.3

8.0
1
1-A
39.3

8.0
1
1-A
39.3

8.0
1
1-A
40.3

9.0
1 7/16
1-A
42.3

9.0
1 7/16
1-A
42.3

8.6
1 7/16
1-B
41.8

11.0
1 15/16
2-B
43.8

11.0
1 15/16
2-B
43.8

517
428-606
1200

588
499-677
1200

588
449-677
1200

695
606-784
1200

618
538-697
1200

618
538-697
1200

795
713-878
1200

622
557-687
1100

622
557-687
1100

17.8

17.8

17.8

17.8

15.9

15.9

13.8

10.8

10.8

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

9.1210.99

6.679.43

6.679.43

59

Application data (cont)


MEDIUM-ST ATIC DRIVE DATA, 5 0 Hz - ENGLISH

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.7-4.7

4.0-5.0

4.3-5.3

4.3-5.3

2.5

2.5

2.5

2.5

2.5

3.0

2.5

3.0

3.0

8.0
1
1-A
40.3

7.0
1
1-A
41.3

7.0
1
1-A
41.3

6.0
1
1-A
37.3

7.5
1 7/16
1-A
39.3

7.9
1 7/16
1-B
39.8

7.0
1 7/16
2-A
36.8

9.4
1 15/16
2-B
39.8

9.4
1 15/16
2-B
39.8

695
606-784
1200

794
692-896
1200

794
692-896
1200

926
808-1045
1200

741
646-836
1200

756
667-848
1200

916
814-1018
1200

728
652-803
1100

728
652-803
1100

17.8

20.4

20.4

23.7

19.0

15.1

20.4

12.6

12.6

10.4412.32

10.4412.32

10.4412.32

10.4412.32

10.4412.32

9.1610.99

9.1610.99

6.679.43

6.679.43

HIGH-ST ATIC DRIVE DATA, 5 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. - Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

3.4-4.4

3.4-4.4

3.4-4.4

4.0-5.0

3.4-4.4

4.0-5.0

4.0-5.0

4.3-5.3

4.3-5.3

2.5

2.5

2.5

3.0

2.5

3.0

3.0

3.0

3.0

6.0
1
1-A
37.3

5.5
1
1-A
37.3

5.5
1
1-A
37.3

5.5
1
1-A
36.3

6.0
1 7/16
2-A
36.3

7.0
1 7/16
2-A
39.3

6.4
1 7/16
2-A
34.3

8.0
1 15/16
2-B
36.8

8.6
1 15/16
2-B
37.8

926
8081045
1200

1010
8811140
1200

1010
8811140
1200

1166
10361200*
1200

926
8081045
1200

916
8141018
1200

1002
8911113
1200

855
766944
1100

795
713878
1100

23.7

25.9

25.9

21.6

23.7

17.0

18.5

14.8

13.8

10.4412.32

10.4412.32

10.4412.32

91610.99

9.1610.99

9.1610.99

8.1610.02

6.679.43

6.679.43

*It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 1200 rpm.

60

ENGLISH

STANDARD DRIVE DATA, 6 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

SI

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

61.086.4

71.196.5

71.196.5

86.4111.8

71.196.5

71.196.5

94.0119.4

109.2134.6

109.2134.6

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

224
25.4
1-A

224
25.4
1-A

224
25.4
1-A

224
25.4
1-A

229
36.5
1-A

229
36.5
1-A

239
36.5
2-B

1024

1049

1049

1074

1074

1074

1062

279
49.2
2-B*
(2) 1087
(2) 1113

279
49.2
2-B*
(2) 1087
(2) 1113

9.5
7.8-11.1
20.0

10.8
9.2-12.4
20.0

10.8
9.2-12.4
20.0

12.7
11.1-14.4
20.0

10.5
9.0-12.1
20.0

10.5
9.0-12.1
20.0

12.9
11.3-14.4
20.0

12.5
11.4-14.0
18.3

12.5
11.2-13.9
18.3

0.327

0.327

0.327

0.328

0.318

0.318

0.255

0.218

0.218

265-313

265-313

265-313

265-313

265-313

265-313

232-279

169-240

169-240

*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.

MEDIUM-ST ATIC DRIVE DATA, 6 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

SI

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

86.4111.8

86.4111.8

86.4111.8

86.4111.8

86.4111.8

94.0119.4

109.2134.6

109.2134.6

109.2134.6

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

3.0

224
25.4
1-A

203
25.4
1-A

203
25.4
1-A

203
25.4
1-A

208
36.5
1-A

218
36.5
1-B

239
36.5
2-B

1074

1024

1024

1024

1049

1062

1062

239
49.2
2-B*
(2) 986
(2) 1011

239
49.2
2-B*
(2) 986
(2) 1011

12.7
11.114.4
20.0

14.0
12.215.8
20.0

14.0
12.215.8
20.0

14.0
12.215.8
20.0

13.7
11.915.4
20.0

14.0
12.415.7
20.0

14.7
13.316.4
20.0

14.7
13.316.4
18.3

14.7
13.316.4
18.3

0.328

0.360

0.360

0.360

0.352

0.278

0.255

0.255

0.255

265-313

265-313

265-313

265-313

265-313

265-313

232-279

169-240

169-240

*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.

61

Application data (cont)


HIGH-ST ATIC DRIVE DATA, 6 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

SI

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

86.4111.8

86.4111.8

86.4111.8

86.4111.8

94.0119.4

109.2
134.6

109.2134.6

109.2134.6

109.2134.6

2.5

2.5

2.5

2.5

3.0

3.0

3.0

3.0

3.0

178
25.4
1-A
1049

152*
25.4
1-A
947

152
25.4
1-A
947

152
25.4
1-A
947

188
36.5
1-B
1011

201
36.5
1-B
1011

188
36.5
2-B
935

203
49.2
2-B
935

203
49.2
2-B
960

16.0
14.018.1
20.0

18.7
16.320.0*
20.0

18.7
16.320.0
20.0

18.7
16.320.0
20.0

16.3
14.418.3
20.0

17.7
15.819.5
20.0

18.6
16.920.0
20.0

17.1
14.617.9
18.3

17.1
14.617.9
18.3

0.410

0.478

0.478

0.478

0.323

0.307

0.323

0.278

0.278

265-313

265-313

265-313

265-313

265-313**

232-279

207-255

169-240

169-240

*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm
and resulting fan speed is 14.0-18.3 r/s.
It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed
20 r/s.
**575-v unit has a center distance of 233-279.

STANDARD DRIVE DATA, 5 0 Hz - SI

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

62

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

61.086.4

71.196.5

71.196.5

86.4111.8

86.4111.8

86.4111.8

109.2134.6

109.2134.6

109.2134.6

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

203
25.4
1-A
998

203
25.4
1-A
998

203
25.4
1-A
998

203
25.4
1-A
1024

229
36.5
1-A
1074

229
36.5
1-A
1074

218
36.5
1-B
1062

279
49.2
2-B
1113

279
49.2
2-B
1113

8.6
7.110.1
20.0

9.8
8.311.3
20.0

9.8
8.311.3
20.0

11.6
10.113.1
20.0

10.3
9.011.6
20.0

10.3
9.011.6
20.0

13.3
11.914.6
20.0

10.4
9.311.5
18.3

10.4
9.311.5
18.3

0.297

0.297

0.297

0.297

0.265

0.265

0.230

0.180

0.180

265-313

265-313

265-313

265-313

265-313

265-313

232-279

169-240

169-240

MEDIUM-ST ATIC DRIVE DATA, 5 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

86.4111.8

86.4111.8

86.4111.8

86.4111.8

86.4111.8

94.0119.4

101.6127.0

109.2134.6

109.2134.6

2.5

2.5

2.5

2.5

2.5

3.0

2.5

3.0

3.0

203
25.4
1-A
1024

178
25.4
1-A
1049

178
25.4
1-A
1049

152
25.4
1-A
947

191
36.5
1-A
998

201
36.5
1-B
1011

178
36.5
2-A
922

239
49.2
2-B
1011

239
49.2
2-B
1011

11.6
10.113.1
20.0

13.2
11.514.9
20.0

13.2
11.514.9
20.0

15.4
13.517.4
20.0

12.4
10.813.9
20.0

12.6
11.114.1
20.0

15.3
13.617.0
20.0

12.1
10.913.4
18.3

12.1
10.913.4
18.3

0.297

0.340

0.340

0.395

0.317

0.252

0.340

0.210

0.210

265-313

265-313

265-313

265-313

265-313

232-279

232-279

169-240

169-240

HIGH-ST ATIC DRIVE DATA, 5 0 Hz -

UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. - Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1/2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)

SI

SI

40RM
007

40RM
40RMQ
40RMS
008

40RMS
010

40RM
40RMQ
40RMS
012

40RM
40RMS
014

40RM
40RMQ
40RMS
016

40RM
40RMS
024

40RM
40RMS
028

40RM
40RMS
034

86.4111.8

86.4111.8

86.4111.8

101.6127.0

86.4111.8

101.6127.0

101.6127.0

109.2134.6

109.2134.6

2.5

2.5

2.5

3.0

2.5

3.0

3.0

3.0

3.0

152
25.4
1-A
947

140
25.4
1-A
947

140
25.4
1-A
947

140
25.4
1-A
922

152
36.5
2-A
922

178
36.5
2-A
998

163
36.5
2-A
871

203
49.2
2-B
935

218
49.2
2-B
960

15.4
13.517.4
20.0

16.8
14.719.0
20.0

16.8
14.719.0
20.0

19.4
17.320.0*
20.0

15.4
13.517.4
20.0

15.3
13.617.0
20.0

16.7
14.918.6
20.0

14.3
12.815.7
18.3

13.3
11.914.6
18.3

0.395

0.432

0.432

0.360

0.395

0.283

0.308

0.247

0.230

265-313

265-313

265-313

234-279

232-279

232-279

207-255

169-240

169-240

*It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 20 r/s.

63

Guide specifications
Commercial Packaged Air-Handling Unit
HVAC Guide Specifications
SizeRange: 2,400 to 12,000 CFM (1150 to 5650 L/s),
Nominal Airflow 6 t o 3 0 Tons (21 to
105 kW), Nominal Cooling
Carrier Model Numbers: 40RM (Direct-Expansion Coil)
40RMQ (Direct-Expansion
Heat Pump Coil)
40RMS (Chilled Water Coil)
Part 1 - GENERAL
1.01 SYSTEM DESCRIPTION
A. Indoor, packaged air-handling unit for use in commercial split systems.Unit shall have a multiposition design and shall be capable of horizontal or vertical
installation on a floor or in a ceiling, with or without
ductwork. (Only vertical units are to be applied without ductwork.)
B. Unit with direct-expansioncoil shall be used in a refrigerant circuit with a matching air-cooled condensing unit. Unit with chilled water coil shall be used
in a chilled water circuit.
1.02 QUALITY ASSURANCE
A. Coils shall be designed & tested in accordance with
ASHRAE 15 Safety Code for Mechanical Refrigeration (U.S.A.), latest edition.
B. Unit shall be constructed in accordance with ETL
(U.S.A.) and ETL, Canada, standardsand shall carry
the ETL and ETL, Canada, labels.
C. Unit insulation and adhesive shall comply with
NFPA-90A (U.S.A.)requirements for flame spread
and smoke generation.

D. Unit shall be manufactured in a facility registered to


the ISO 9002 manufacturing quality standard.
E. Direct-expansionand chilled water coils shallbe burst
and leak tested at 435 psi (2999 kPa).
1.03 DELIVERY AND STORAGE
Units shall be stored and handled per manufacturer's
recommendations.
Par t 2 - Products
2.01 EQUIPMENT
Indoor mounted, draw-thru, packaged air-handling unit
that can be used in a suspended horizontal configuration or a vertical configuration. Unit shall consistof
forward-curved belt-driven centrifugal fan(s), motor &
drive assembly,prewired fan motor contactor, factoryinstalledrefrigerant metering devices(direct-expansion
coil units), cooling coil, 1-in. (25.4-mm) washable air
filters, and condensate drain pans for vertical or horizontal configurations.

64

A. Base Unit (Painted):


1. Cabinetshall be constructed of zinc coated steel
and polyester powder painted to protect them
from corrosion in the harsh Middle Eastern climate
and also to increase the colour life in high ultraviolet (UV) radiation regions.
2. Cabinet panels shall be fully insulated with 1/2 in.
(12.7-mm) fire-retardant material.
3. Unit shall contain PVC condensate drain pans for
both vertical and horizontal applications. Drain
pans shallhave connectionson right and left sides
of unit to facilitate field connection. Drain pans
shall have the ability to be sloped toward the right
or left side of the unit to prevent standing water
from accumulatingin pans.
4. Unit shall have factory-supplied 1-in. (25.4 mm)
washable-type filters installed upstream from the
cooling coil. Filter access shall be from the front
of the unit.
B. Coils:
Coils shall consist of 3 rows (40RM, 40RMQ008,
40RMS), or 4 rows (40RMQ012,016) of copper tubes
with sine-wave aluminum fins bonded to the tubes by
mechanical expansion. Suction and liquid line connectionsor supply and discharge connectionsshallbe
made on the same side of the coil.
1. Direct-expansioncoilsshallfeaturefactory-installed
thermostatic expansion valves (TXVs) for refrigerant control. The TXVs shall be capable of external adjustment. Direct-expansion heat pump
coils shall have a factory-installedbypassline and
check valve assemblyaround the TXVs to allow
liquid flow from the coil to the outdoor unit during
the heating mode. Coil tubing shall be internally
rifled to maximize heat transfer.
2. Chilled water coils shall be rated for an operating
pressureof not lessthan 300 psig (2069 kPag).
C. Operating Characteristics:
cfm (L/s)
Unit shall be capable of providing
in. wg
airflow at an external static pressureof
(kPag).
D. Motor:
Fan motor of the size and electrical characteristics
specified on the equipment scheduleshall be factory
supplied and installed.
Motors rated at 1.3 through 3.7 hp (0.97 through
2.76 kW) shall have internal thermal overload protection. Motors rated at 5, 7 1/2 , and 10 hp (3.73,
5.60, and 7.46 kW) shall be protected by a circuit
breaker.

E. Factory-InstalledOptions:
1. Alternate Motor and Drive:
An alternate motor and/or medium- or high-static
drive shall be available to meet the airflow and
external static pressure requirements specified
on the equipment schedule.
2. Unpainted Units:
Where conditions require, units can be provided
unpainted. However check for the availability.
F. Field-InstalledAccessories (ordered from NAO):
1. Hot Water Coil:
Coil shallbe 2-row, U-bendcoil with copper tubes
and aluminum plate fins bonded to the tubes by
mechanicalexpansion. Coil shall be mounted in
a galvanizedsteel housing that shall be fastened
to the unit's fan deck for blow-thru heating operation. Coil shall have maximum working pressure of 150 psig (1034 kPag).
2. Steam Distributing Coil:
Coil shallconsistof one row of copper tubeswith
aluminum plate fins, and shall have inner steam
distributing tubes.Coil shallbe mounted in a galvanizedsteelhousingand shallbe fastenedto the
unit's fan deck for blow-thru heating operation.
Coil shall have maximum working pressure of
175 psig at 400 F (1207 kPag at 204.4 C).
3. Electric Heaters:
Heaters for nominal 240, 480, or 575-volt,
3-phase, 60 Hz; and 240, 400-volt, 3 phase,
50 Hz power supply shallbe factory-suppliedfor
field installationasshown on the equipmentdrawings. Electricheat assemblyshallbe ETL (U.S.A.)
and ETL, Canada, agency approved, and shall
have single-point power wiring. Heater assembly shallincludecontactorswith 24-V coils, power
wiring, 24-v control wiring terminal blocks, and
a hinged accesspanel. Electric heaters shall not
be used with air discharge plenum.
4. Air Discharge Plenum:
Plenum shall be factory supplied to provide freeblow air distribution for vertical floor-mounted
units. A grille with moveable vanes for horizontal or vertical airflow adjustment shall be
included. Plenum shall be field-assembledand
field-installedon the unit's fan deck for blow-thru
air distribution. Plenum shall not be used with
electric heaters.
5. Return Air Grille:
Grille shall be factory supplied for field installation on the unit's return air opening.

6. Unit Subbase:
Subbaseassemblyshall be factory supplied for
field installation. Subbase shall elevate floormounted vertical units to provide access for
correct condensate drain connection.
7. Economizer:
Economizerfor ventilation or ``free'' cooling shall
be factory provided for field installation on either
return air opening of air handler. For free cooling applications, economizershallbe compatible
with separate thermostat; economizer dampers
shall open when outdoor air enthalpy is suitable
for free cooling. Economizershall be compatible
with separate CO2 sensor accessory; economizer
dampersshall open when indoor CO2 level rises
abovepredetermined setpoint. Economizershall
include enthalpy control and damper actuator.
8. Thermostat Controls:
a. Debonair programmablemulti-stagethermostatwith 7-dayclock, holiday scheduling,large
Thermoglow display, remote sensorcapability, and Title 24 compliance.
b. TEMP System programmable communicating multi-stage thermostat with fan switch,
time clock, LCD display,F/C capability,and
CCN compatiblity.
c. CommercialElectronicThermostatwith 7-day
time clock, auto-changeover, multi-stagecapability, and large LCD temperature display.
d. Non-programmablethermostatwith fan switch
subbase.
9. Overhead SuspensionPackage:
Package shall include necessary brackets to
support units in a horizontal ceiling installation.
10. CO2 Sensor:
Sensorshallprovide the ability to signalthe economizer to open when the spaceCO2 levelexceeds
the predetermined set point. Sensor shall have
the capability of being connected to Comfort
System relay pack or to economizer using fieldsupplied and -installed Honeywell dc adapter
no. Q769C1004.
11. CondensateDrain Trap:
Trap shall have transparent, serviceabledesign
for easycleaning. Kit shallinclude overflow shutoff switch and wiring harnessfor connection to
an alarm if desired.

65

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Copyright 2000 Carrier Corporation

Form 40RM-3PD-S Replaces: New

You might also like