Professional Documents
Culture Documents
iO Series
Intelligent Control
iO Series
Initiating
Devices
Submittal Guide
An EDWARDS brand.
Se
w.
e w
no
w
h a ha ts possible
..
t
w.
's
possible
no
Door Holders
& Relays
iO Series
Intelligent Control
Project: ___________________________
Contact: ___________________________
Date:
___________________________
Initiating
Devices
Notification
Appliances
_____________________________
Door Holders
& Relays
Hazardous Location
Devices
to each product. All these sheets, along with guide specifications and other
iO Series
Intelligent Control
Initiating
Devices
Submittal Guide
iO Series
Notification
Appliances
Hazardous Location
Devices
Door Holders
& Relays
iii
iO Series
Life Safety Systems
System Specifications....................................................... 2
Control Panels................................................................... 3
Option Cards..................................................................... 4
Power Supplies................................................................. 6
Remote annunciation........................................................ 8
Accessories..................................................................... 10
Notification Appliances
23
Firefighters Telephones................................................... 31
Accessories..................................................................... 34
Audible Signals................................................................ 33
35
Initiating Devices............................................................. 36
Notification Appliances.................................................... 37
38
Door Holders................................................................... 38
Relays............................................................................. 39
SPDT Relays................................................................... 39
Door Holders
& Relays
Hazardous Location
Devices
Notification
Appliances
Initiating
Devices
iO Series Analog
iO Series
Intelligent Control
Cohesive,
comprehensive
analog addressable
fire alarm for small
buildings.
See whats
possible now.
D e t e c t i o n
&
A l a r m
S i n c e
1 8 7 2 .
Mass Notification Smoke Detection Graphical Monitoring and Control Instant Messaging Aspirating Smoke Detectors Industrial
Signaling Voice Evacuation Smoke Control Fire Suppression Intercom Timekeeping CO Detection Heat Detection
Audible & Visible Signaling Voicemail Messaging Duct Smoke Detection Giant Voice Electronic Signage Area of Rescue
iO Series
Intelligent Control
Specifications p. 2
Control Panels p. 3
Option Cards p. 4
Power Supplies p. 6
Remote annunciation p. 8
Accessories p. 10
iO Series
Intelligent Control
iO Series life safety systems are a powerful intelligent solution for small to mid-sized buildings. Advanced analog technology delivers the benefits of flexible system installation,
while a clean and easy-to-operatate user interface makes
panel operation and system maintenance quick and intuitive.
Door Holders
& Relays
Hazardous Location
Devices
Notification
Appliances
iO Series
iO Series
Intelligent Control
Intelligent Control
Specifications
Device loops
Notification appliance
circuits
Power supply
NAC Operating
SLC Loop operating
Primary power
Aux Power 1
Aux Power 2
Auxiliary output
Base panel current
Battery placement
Batteries
Loop circuit
iO64
iO500
1 loop Class B, Class A optional,
1 loop, expandable to 2, Class A or B,
supports up to 64 devices
each loop supports up to 250 devices
2 Class B, Class A optional, 2.5 amps 4 Class B or 2 Class A, 2.5 amps each
each
3.75 A FWR total at 120/230 VAC 60
6.0 A total, 2.5 A max. per circuit at
Hz
120/230 VAC 60 Hz. 5.0 A total at
3.0 A FWR total at 230 VAC 50 Hz
230VAC 50 Hz, 2.5 A max. per circuit
0.5 amps aux power
0.5 amps aux power
24 VDC. NAC minimum voltage: 19.5 VDC @ 20.4 V battery voltage
20 V peak-to-peak
120 VAC, 60 Hz, 230 VAC 50-60 Hz
Continuous circuit: 24 VDC nominal at 500 mA. A SMK module is required when
using the SIGA-UM module to support two-wire smoke detectors.
Resettable circuit: 24 VDC nominal at 500 mA.
19 to 25.7 VDC
Standby: 155 mA Alarm: 204 mA
Standby: 172 mA, Alarm: 267 mA
Accommodates up to 10 A/H
Accommodates up to 18 A/H batteries.
batteries. Use external cabinet for
Use external cabinet for larger batteries.
larger batteries.
Batteries must be sealed lead acid type only. Maximum charging capacity = 26
Ah.
Maximum loop resistance: 66 .
Maximum loop resistance: 66 .
Maximum loop capacitance: 0.7 F.
Maximum loop capacitance: 0.5 F.
Style 4, 6, and 7 wiring. 64 isolators
Style 4, 6, and 7 wiring. 64 isolators
maximum
maximum.
1.5 mA (see the UL and ULC compatibility list for your panel
for the maximum quantity of detectors per circuit)
100
Form C 24 VDC @ 1 A (resistive load)
Form C 24 VDC @ 1 A (resistive load)
Form A 24 VDC @ 1 A (resistive load)
Temperature: 0 to 49C (32 to 120F). Humidity: 0 to 93% RH, noncondensing
All terminals rated for 12 to 18 AWG (0.75 to 2.5 sq mm)
Voltage: 2.55 V. Current: 30 mA max
8 drops max, RS-485 Class B, Class A
16 max.
32 max.
UL, CSFM and ULC
Specifications
DACT/Dialer
RS-232
Diagram represents an
iO500 system wired for
Class A operation with
a full complement of
option cards.
iO Series
Intelligent Control
SUBMIT
Control Panels
All iO Series life safety systems feature an attractive design that
fits with any decor. Its distinctive doorfront offers a contemporary
look thats available with red or silver finishes. All LED indicators
and its large backlit display remain easy to see at all times.
Dimensions
Surface mounting holes
D3
D2
D1
D4
D5
D6
Notification
Appliances
Initiating
Devices
Standard Features
iO Series
Intelligent Control
Hazardous Location
Devices
iO500GD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Gray door, surface enclosure, 115VAC, English.
1 Loop System, 500 analog point capacity, 4 NACs, red Door, surface enclosure, 115VAC, English.
iO500R-2 1 Loop System, 500 analog point capacity, 4 NACs, red door, surface enclosure, 230VAC, English
iO500RD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Red Door, surface enclosure, 115VAC, English.
D16L-iO-2 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to right of display.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM2 Flush mount trim, black
iO64 Intelligent Single Loop Systems, Data Sheet 85005-0131
iO64G
1 Loop System, 64 analog point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English.
iO64GD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Gray door, surface enclosure, 115VAC, English.
iO64R
1 Loop System, 64 analog point capacity, 2 Class B NACs, Red Door, surface enclosure, 115VAC, English.
Door Holders
& Relays
iO64RD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Red Door, surface enclosure, 115VAC, English.
iO64G-2 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 230VAC, English.
iO64R-2 1 Loop System, 64 point capacity, 2 Class B NACs, Red door, surface enclosure, 230VAC, English.
iO64GL
1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English, Canadian.
iO64GL-F 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, French, Canadian.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM1 Flush mount trim, black
iO Series
Intelligent Control
iO Series
Intelligent Control
SUBMIT
Option Cards
SA-232 RS-232
interface
SA-CLA Class A
Module
iO-Series panels are supported by a complete line of modules and related equipment that
enhance performance and extend system capabilities. Option cards are easy to install and set
up. They simply plug directly into the control panel main circuit board or are connected to it
with a ribbon cable. After installation, terminals remain easily accessible for quick connection of
field wiring. The cabinet provides ample room for wire routing, keeping wiring neat and easy to
service at all times.
SA-CLA wiring
NAC1
TB2 on main
circuit board
NAC1+
NAC2
NAC2+
+
+
Class A card installed
on main circuit board
SA-CLA
Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board.
SA-ETH wiring
Network cable
To network
connection
The SA-ETH card provides a standard 10/100 Base T Ethernet network connection
for connecting to an intranet, a local network, or the Internet. The card can be used
to upload and download panel configuration, history, and current status from the
iO-CU to the panel over the network.
The Ethernet card is installed on the plastic assembly and connects to the main
circuit board via a ribbon cable.
Ethernet card
SA-ETH
Ethernet Port, Slave, for Ethernet connection to local area networks. Mounts in cabinet on base plate.
SA-232 wiring
GND (black wire)
TXD (white wire)
RXD (red wire)
SA-232
Serial Port (RS-232), for connection to printers & computers, mounts in cabinet to base plate
iO Series
Intelligent Control
SUBMIT
SA-DACT
wiring
Phone line 1
Phone line 2
Phone cables
(supplied)
To wall
phone jack
RJ31 jacks
SA-DACT Dialer
Initiating
Devices
The SA-DACT provides communications between the control panel and the central
station over a telephone line system. It transmits system status changes (events)
to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to
two different account and telephone numbers. The modem feature of the SA-DACT
can also be used for uploading and downloading panel configuration, history, and
current status to a PC running the iO-CU.
The dialer phone lines connect to connectors on the dialers main circuit board.
Phone line 1 connects to connector J4 and phone line 2 connects to connector J1.
SA-DACT
Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate
The SMK Smoke Power Converter Module provides a backup power source for
two-wire smoke circuits connected to a Signature data circuit. The SMK monitors
the operating power from the power supply. When power begins to degrade, the
SMK provides the necessary operating voltage to the two-wire smoke detection
circuits.
SMK
24 VDC
auxilliary
24
VDC
power
(notauxilliary
resettable)
power
(not resettable)
+
_
+
_
8 7 6 5
SMK
Loop
device
Loop
device
Loop card
Class A wiring
Class B Wiring
Loop 1 SEC
Data Line
-+
Loop
Loop
device Loopdevice
card
Loop card
Data Line
Loop
device
Loop
device
XAL250
Data Line
Loop
device
8 7 6 5
4 3 2 1
8 7 6 5
4 3 2 1
Data in +
Data in
+
Two-wire smoke
detectors
Two-wire smoke
detectors
16 15 14 13 3 2 1 12 11 10 9
3 2 1 12 11 10 9
16 15 14 13 JP1
JP1
8 7 6 5
4 3 2 1
8 7 6 5
4 3 2 1
Loop
device
Signature Loop Expansion Module. Adds second loop to iO500 systems, 250 point capacity.
Door Holders
& Relays
Class AXAL250
wiring
The
Loop Expander Card provides an additional Signature
Series device loop on the control panel. The card expands the control
panels device
capacity to 500 total device addresses, 250 per loop.
Loop 1 SEC
The card is+compatible with Class B or Class A wiring. It is compatible
with iO500 -control panels+only. The
+ loop expander card mounts in
Loop 1 PRI
the cabinet+and connects to
J7 on the main circuit board.
- connector
Loop card
16 15 14 13 3 2 1 12 11 10 9
JP1
+Loop 1 PRI
Two-wire smoke
detectors
Two-wire smoke
detectors
+
4 3 2 1
JP1
2 1 12 11 10 9
16 15 14 13 3
Class A Wiring
+
Power+out
Power
+
+ in
Power
4 3 2 out
1
+ +
Data Line
Hazardous Location
Devices
Loop 1 PRI
+ +
Power
8 7 6 in5
SMK
Loop 1 SEC
Loop 1 PRI
Notification
Appliances
Loop 1 SEC
iO Series
Intelligent Control
Terminate
or to next
UM
Terminate
or to next
UM
Data out
Data out
iO Series
Intelligent Control
iO Series
Intelligent Control
SUBMIT
Power Supplies
Remote Booster Power Supply
The Remote Booster Power Supply is a self-contained 24 Vdc power supply designed to
augment fire alarm audible and visual power requirements as well as provide power for
auxiliary, access control and security applications. The booster contains all of the necessary
circuits to monitor and charge batteries, control and supervise four Class B or two Class A
NAC circuits and monitor two controlling inputs from external sources.
Simple switch selection provides a wide variety of operational configurations. Each remote
booster power supply is supplied with its own enclosure providing ample space for additional
interface modules and battery compartment.
NAC
Circuit
Sense
NAC
Booster
Power Supply
Sense
NAC
Booster
Power Supply
When used with Genesis Notification appliances, the booster provides the ability to synchronize strobes as well as horn signals. The booster flexibility allows synchronization with
upstream devices, or, the booster may be used to synchronize downstream devices, as
NAC
Series Connection
well as otherSense
boosters andUptheir
connected devices.
to ten boosters
can be connected
together
Booster
BPS notification
circuits easily configure for either of two signaling rates: 3-3-3
Powerappliance
Supply
temporal or continuous. This makes the BPS ideal for applications requiring signaling rates
not available from the main panel. It also allows independent setup of a notification appliance circuit without interfering with the main panel and its initiating circuits. In addition to
the generated
signal rates, the BPS can also be configured to follow the signal rate of the
Parallel Connection
The number of boosters
can be connected
mainthatpanels
notification appliance circuit. This allows seamless expansion of existing NACs.
together is limited by wire
run length and available current
For comprehensive configuration and wiring details, refer to the BPS Application Guide,
85001-0582.
Parallel Connection
The number of boosters
that can be connected
together is limited by wire
run length and available current
BPS6A
BPS6A/230
BPS10A
BPS10A/230
3-TAMP
Tamper switch
iO Series
Intelligent Control
SUBMIT
NAC2
Notification
appliance
circuit (NAC)
NAC3
NAC4
TB5
EOL
[3]
AC power fail
monitoring
TB2
APS6A
APS6A/230
APS10A
APS10A/230
Data Sheet 85005-0127
Data Sheet 85005-0127
6 Volt Batteries
6V8A (8 Ah)
Data Sheet 85005-0127
Data Sheet 85005-0127
Hazardous Location
Devices
Battery Cabinet
Notification
Appliances
NAC
The Auxiliary Power Supply (APS) is a selfcontained 24 Vdc power supply designed
to augment fire alarm audible and visual
power requirements as well as provide
auxiliary power for life safety and security
applications. The APS contains all of the
necessary circuits to monitor and charge
batteries, control and supervise four Class
B or two Class A NAC circuits and monitor two controlling inputs from external
sources.
Initiating
Devices
200 mA AUX
Continuous
IN
Sense 1 COM
OUT
IN
Sense 2 COM
OUT
NO
Trouble COM
NC
Notification
appliance
circuit (NAC)
NAC1
iO Series
Intelligent Control
Door Holders
& Relays
7
iO Series
Intelligent Control
iO Series
Intelligent Control
SUBMIT
annunciation
Remote
Edwards R-Series Annunciators are highperformance remote annunciators that provide
status indication and common controls for
compatible fire alarm control panels, including iOSeries small analog fire alarm systems. This family
of annunciators offers LCD or LED annunciation.
Models are available with and without common
controls.
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Reset
Signal Silence
Drill
Lamp Test
RLCD-C
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Lamp Test
RLCD
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Ack/Silence
Reset
Reset
Signal Silence
Signal Silence
Drill
Drill
Lamp Test
Lamp Test
RLED-C
RLCD-C
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
CH1
Lamp Test
RLED24
RLCD
24V () IN
24V () IN
Ack/Silence
24 VDC
(+) OUT
24V (+) OUT enA keyswitch and graphic annunciator interface is available for R-Series annunciator24Vapplications.
The keyswitch
24V () OUT
24V () OUT
ables or disables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on
GROUND
GROUND
the graphic panel display.
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Reset
Signal Silence
Wiring, Class A
FACP
RS-485
RLED-C
Lamp Test
Annunciator
Annunciator
CH1 (+) IN
CH1 (+) IN
CH1 +
CH1 () IN
CH1 () IN
CH1
CH2 +
CH1 () OUT
CH1 () OUT
CH2
CH2 (+) IN
CH2 (+) IN
CH2 () IN
CH2 () IN
CH2 () OUT
CH2 () OUT
24 VDC +
24V (+) IN
24V (+) IN
24 VDC
24V () IN
24V () IN
24V () OUT
24V () OUT
GROUND
GROUND
LISTED 24 VDC
SUPPLY
RLED24
FACP
Annunciator
Annunciator
RS-485
CH1 (+) IN
CH1 (+) IN
CH1 +
CH1 () IN
CH1 () IN
CH1
CH1 () OUT
CH1 () OUT
CH2 (+) IN
CH2 (+) IN
CH2 () IN
CH2 () IN
CH2 () OUT
CH2 () OUT
24 VDC +
24V (+) IN
24V (+) IN
24 VDC
24V () IN
24V () IN
24V () OUT
24V () OUT
GROUND
GROUND
LISTED 24 VDC
SUPPLY
RLCD
FACP
RLCD-R
RLCDF
CH1
RS-485
CH1 +
CH1 (+) IN
CH1 (+) IN
CH1 () IN
CH1 () IN
(+) OUT
CH1 (+) OUT
LCD text CH1
annunciator
without common
controls. French.
RLCD-C
RLCD-CF
24 VDC +
V ()
V ()
V ()
V (+)
V (+)
V (+)
V ()
V ()
CH2 () IN
CH2 () OUT
CH2 () OUT
24V () IN
24V () IN
24V () OUT
24V () OUT
GROUND
GROUND
24 VDC
Second Expander
OUT
CH2 () IN
(+) OUT
CH2controls.
(+) OUT
LCD text CH2
annunciator
with common
English. Red.
SUPPLY
IN
CH1 () OUT
(+) IN
CH2controls.
(+) IN
LCD text CH2
annunciator
with common
English.
RLCD-CR
LISTED 24 VDC
First Expander
CH1 () OUT
RLED-C
16-pair LED
annunciator with24Vcommon
controls. English.
24V (+)zone
OUT
(+) OUT
RLED-CR
Data
Sheet 85005-0128
E
E
E
Data
Sheet 85005-0128
C
C
C
Data
Sheet 85005-0128
A
A
A
B
RLED-CF
RLED24
24-pair LED zone expander with expander cable and zone card insert.
Expander
Expander
RLED24R Annunciator24-pair LEDFirst
zone
expander withSecond
expander
cable and zone card insert. Red.
RKEY
OUT
V ()
V (+)
Wiring, Class B
Drill
IN
OUT
IN
OUT
)
V () on plate for enabling
V ()
V () or disabling common controls (Lock/Unlock).
Remote keyV (switch
Data Sheet 85005-0128
V (+)
V (+)
V (+)
V (+)
iO Series
Intelligent Control
SUBMIT
Annunciator Enclosures
The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each consists of a back plate, hinged cover,
and key lock. The enclosures are 16-gauge welded steel with a white, painted
finish. Each enclosure includes a security lock and two keys. The two- and threeposition enclosures have wiring channels for correct routing of interconnections.
The enclosures attach to a standard electrical box, and provide a mounting lip
that takes the place of the integral mounting ring supplied with the annunciators
and expanders.
RA-ENC1
Initiating
Devices
RA-ENC3
RA-ENC2
RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander.
RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders.
Notification
Appliances
Graphic Annunication
The GCI series of graphic annunicator drivers allow iO control panels to
display events on an LED-based graphic annunciator. The GCI annunciator card supports 32 LEDs on the graphic panel display. It includes
status LEDs and an internal buzzer. The graphic card is supplied with
snap track mounting. It is attached to a plastic mounting rail that requires
two EIA panels.
GCI
Hazardous Location
Devices
iO Series
Intelligent Control
24VDC TO NEXT
POWER MODULE
Door Holders
& Relays
9
iO Series
Intelligent Control
iO Series
Intelligent Control
SUBMIT
Accessories
Riser out to next device
or EOL Relay
CTM
Riser in
from
Panel
Alarm/Supervisory Wiring
Master Box
CC1
/MCC1
CTM
Data in
Municipal
Circuit
Data out
RPM
PT-1S
PT-1S/220
10
Serial Printer
iO Series
Intelligent Initiating Devices
Signature Series
Intelligent Analog
Initiating Devices
intelligent analogaddressable system is an entire family of life safety detectors
as well as mounting bases, multiple-function input and output
modules, and user-friendly maintenance
and service tools.
Making the best of true multisensor capability, Signature Series detectors continually monitor the protected space with their
on-board sensors, each of which is finely
tuned to detect a different characteristic
of combustion. All this informat ion is
gathered and run through a sophisticated
algorithm that compares the sensor readings over time to known signatures of fires.
Only when a match is found will an alarm
condition occur. This means that a single
multisensor detector can distinguish between a harmless puff of dust and a wisp
of smoke; between hot, humid weather
and a serious life safety condition.
Fire Detectors p. 13
Detector Bases p. 14
Detector Accessories p. 15
Input/Output Modules p. 16
Pull Stations p. 22
Initiating
Devices
Automatic Device Mapping The Signature Loop Controller learns where each devices serial number address is
installed relative to other devices on the circuit. This mapping function is invaluable for tracking down unexpected
or missing device addresses, or finding changes to wiring.
The System Definition Utility program also uses this mapping feature to produce system layout or As-Built drawings
showing such details as banch wiring (T-taps), device types
and their addresses.
Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a dirty detector
message. The detectors sensitivity measurement can also
be transmitted to the loop controller. A sensitivity report may
be printed to satisfy NFPA sensitivity measurements. The
user-friendly maintenance program shows the current state
of each detector and other pertinent messages. When the
CO sensors electrochemical cell reaches its end of life, the
detector signals a trouble condition to the control panel. The
sensor/daughterboard module is field-replaceable.
Hazardous Location
Devices
Self-diagnostics and History Log Signature Series devices constantly run self-checks to provide
important maintenance information. The results of these
checks are automatically updated and permanently stored
in the devices non-volatile memory.
Notification
Appliances
Class B wiring
Class B wiring
Class A wiring
Class B
Class A
Loop 1 SEC
Typical Wiring
Loop 1 PRI
Door Holders
& Relays
Circuit specifications
1 SEC
Data
Device loops
1 loop,Loop
expandable
to 2, Class
ALine
or B, each loop
+
supporting up to 250 device addresses
+
+
LoopMaximum
1 PRI
Com. line voltage
20 V peek-to-peek
+
Circuit current
0.5 A max Loop
Loop
device
device
Circuit impedance
Loop66
card total, 0.5 F, max
Isolators
64 maximum
Loop 1 SEC
Data Line
+Loop 1 PRI
Loop
device
Loop
device
Loop card
-+
Loop
Loop
device Loopdevice
card
Data Line
Class A wiring
Loop 1 SEC
11
iO Series
Intelligent Initiating Devices
iO Series
Intelligent Control
SUBMIT
In addition to integrated smoke and heat sensors, Signature Series combination life safety
devices include electrochemical carbon dioxide sensors. CO detection has rapidly become
a standard part of life safety strategies everywhere. Monitored CO detection is becoming
mandated with increasing frequency in all types of commercial applications, but particularly
in occupancies such as hotels, rooming houses, dormitories, day care facilities, schools,
hospitals, assisted living facilities, and nursing homes. In fact, more than half of the U.S.
population already lives in states requiring the installation of CO detectors in some commercial occupancies. This is because carbon monoxide is the leading cause of accidental
poisoning deaths in America. Known as the Silent Killer, CO is odorless, tasteless, and
colorless. It claims nearly 500 lives, and results in more than 15,000 hospital visits annually.
SIGA2-COS
SIGA2-PHCOS
SIGA2-HCOS
12
SIGA2-PCOS
iO Series
Intelligent Initiating Devices
SUBMIT
Fire Detectors
Intelligent Multisensor Photoelectric/Heat Detector
Contains a fixed-temperature heat sensor to detect heat from fire and a photoelectric smoke sensor to detect smoke.
Unlike simple multi-criteria detectors, the SIGA2-PHS can report the heat and photo elements as separate event types
or together. This permits the photo element of the detector to report, for example, a supervisory event during the
day, and an alarm event at night while the heat element always reports an alarm.
SIGA2-PHS
SIGA-PHS
Initiating
Devices
SIGA2-PS
SIGA-PS
SIGA-HRS
Notification
Appliances
SIGA2-HFS
SIGA-HFS
Hazardous Location
Devices
Duct smoke
detector
Return
air
Duct smoke
detector
Supply
air
HVAC
unit
Remote
test station
SIGA-SD
SD-PH
Sampling Tubes
SD-T8 (8)
SD-T42 (42)
SD-T18 (18)
SD-T60 (60)
SD-T24 (24)
SD-T78 (78)
SD-TRM (magnetic)
SD-TRM (keyed)
Accessories
Door Holders
& Relays
FACP
Less than two inches deep, SuperDuct intelligent smoke detectors are ideal
for installation in ductwork, where space is always at a premium. Offering
the most advanced and most reliable performance in its class, SuperDuct
represents the perfect balance of practical design and advanced technology.
SD-T36 (36)
SD-T120 (120)
13
iO Series
Intelligent Initiating Devices
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
Detector Bases
AB4GT
AB4GT
AB4GT
AB4GT
Listed 24 V
EOL
supervising
equipment
AUX_RISER +
AUX_RISER -
TCDR
SLC +
SLC -
SIGA-AB4GT
SIGA-TCDR
SIGA-AB4G
AB4G-SB
SIGA-SB
SIGA-IB
14
SIGA-RB
iO Series
Intelligent Initiating Devices
Detector Accessories
AUX_RISER_IN +
SUBMIT
AUX_RISER_OUT +
A
To next device
SLC_OUT +
Initiating
Devices
Notification
Appliances
Remote LED
The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base. It features a North
American size one-gang plastic faceplate with a white finish and red alarm LED.
SIGA-LED
Hazardous Location
Devices
Trim Skirt
Use the SIGA-TS Trim Skirt to give Signature detectors a finished look and hide surface
imperfections around the detectors base. Supplied with all four-inch detector bases, the
SIGA-TS4 can also be ordered separately. Use the black model with SIGA-IPHSB.
SIGA-TS
SIGA-TSB
SIGA-TS4
Detector Guard
Door Holders
& Relays
Constructed of sturdy 16-guage steel, the SIGA-DG Smoke Detector Guard is designed
SIGA-PS smoke detectors from damage or tampering. The advanced louver system allows
smoke detectors to be installed at their listed spacing and has no effect on operating sensitivity.
SIGA-DG
SIGA-DGSB
15
iO Series
Intelligent Initiating Devices
iO Series
Intelligent Control
SUBMIT
Signature Series
Input/Output Modules
Signature Series input/output modules are extremely flexible and
Initiating
Devices
powerful devices that gather analog information from the slave devices
Plug-in UIOs
connected to them and convert this data into digital signals. They are
with motherboard
available in models that mount in standard one- or two-gang electrical
boxes, as well as versions that plug into UIO motherboards.
Standard two-gang mount
The actual function of each module is determined by its installerselected personality code. This is downloaded to the module from the
Signature Loop Controller during system configuration. Because they are intelligent devices, all decisions are made
at the module. This allows lower communication speed but very fast control panel response time and less sensitivity
to line noise and loop wiring properties. As a result, twisted or shielded wire is not required.
Application
Waterflow Switches
Class A indicating and initiating circuits,
two-wire smoke detectors
Class B Initiating Circuits:
Door Closers, Fans, Dampers
Telephone Power and Audible/Visual Signal
Power Selector, Strobe Synchronization
Sounder Base power
Fire Suppression
Fault detection
Module
Waterflow/Tamper Module
Universal Class A/B
Module
Class B Input Module
Monitor Module
Control Relay Module
Signal Module
UIO Motherboard
Plug-in UIO
RM
ALA
FIRE DULE
MO
16
iO Series
Intelligent Initiating Devices
SUBMIT
SIGA-UM
SIGA-MAB
SIGA-UM
Initiating
Devices
The Universal Class A/B Module is used to connect initiating, appliance, or two-wire smoke
circuits in either Class A or Class B configurations. The plug-in version can also be used as a
Class A dry contact initiating device circuit. The actual function of this module is determined
by the personality code selected by the installer. Up to fifteen personalities are available.
SIGA-MAB
SIGA-CT1
SIGA-CT1HT
SIGA-CT2
SIGA-MCT2
SIGA-CT1/CT2
Notification
Appliances
The Class B Input Module is used to connect Class B normally-open Alarm, Supervisory, or
Monitor type dry contact initiating device circuits. The standard-mount version is available with
either one or two input connections. The plug-in version accepts two input connections. The
actual function of this module is determined by the personality code selected by the installer.
A total of four personalities are available.
SIGA-MCT2
Single Input Module, high temperature rating (One-gang standard mount) Data Sheet: 85001-0241
Dual Input Module (One-gang standard mount)
Hazardous Location
Devices
SIGA-CC1S
SIGA-MCC1S
Door Holders
& Relays
17
iO Series
Intelligent Initiating Devices
iO Series
Intelligent Control
SUBMIT
Signature Series
Input/Output Modules
Initiating
Devices
Signal Module
The Signal Module is used to connect, upon command from the loop controller, supervised
Class B signal or telephone circuits to their respective power inputs. Models are available with
one or two power inputs. These may be either polarized 24 Vdc to operate audible and visual
signal appliances, or 25 and 70Vrms to operate audio evacuation speakers and firefighters
telephones. The actual function of this module is determined by the personality code selected
by the installer. A total of three personalities are available.
SIGA-CC1
SIGA-MCC1
SIGA-CC2
SIGA-MCC2
SIGA-CC2A
SIGA-MCC2A
SIGA-CR
SIGA-MCR
SIGA-CRR
SIGA-MCRR
SIGA-RM1
SIGA-MRM1
18
iO Series
Intelligent Initiating Devices
SUBMIT
Input/Output Module
SIGA-IO
SIGA-MIO
Initiating
Devices
Waterflow/Tamper Module
SIGA-WTM
Notification
Appliances
The SIGA-WTM Waterflow/Tamper Module is a two circuit intelligent module. Circuit 1 is for Class
B normally-open waterflow alarm switches. When the input contact is closed for approximately 16
seconds, an alarm signal is sent to the loop controller. Circuit 2 is for Class B normally open dry
contact supervisory and tamper switches. When the input contact is closed, an active signal is
sent to the loop controller. Conditions on both circuits are latched at the module.
Data Sheet: 85001-0297
Isolator Module
SIGA-IM
Hazardous Location
Devices
The SIGA-IM Isolator Module is an intelligent device that allows part of the Signature data loop
to continue operating in the event of a short circuit. The module can be wired into a Class
A data loop at any point. A maximum of 96 isolator modules can be installed on one circuit.
If a fault occurs, the isolator cuts power to all devices beyond the isolator on the loop. Once
activated, the line fault isolator continuously checks the faulted side of the loop to determine
if the short still exists. When the fault is cleared, the module automatically restores the entire
data loop to its normal condition.
Data Sheet: 85001-0271
Monitor Module
The SIGA-MM1 is a single-circuit intelligent module that includes a Class B normally-open dry
contact. This is used for monitoring input from devices such as fans, dampers, and doors.
When the input contact is closed, an active signal is sent to the loop controller. The active
condition is not latched at the module.
SIGA-MM1
Door Holders
& Relays
19
iO Series
Intelligent Initiating Devices
iO Series
Intelligent Control
SUBMIT
Signature Series
Input/Output Modules
Universal Input/Output (UIO) Motherboards
Initiating
Devices
Data In
Signature
Data
Circuit
Riser 2 Input
common to
all SIGA-UIO
Modules
Data Out
Jumpers Connect
Riser Input #1
Between Modules
Individual Riser 1 Input to each SIGA-UIO module
SIGA-UIO2R Universal Input/Output Module Board with Riser Inputs 2 Module Positions
SIGA-UIO6R Universal Input/Output Module Board with Riser Inputs 6 Module Positions
SIGA-UIO6
Related Equipment
MFC-A
27193-11
27193-16
27193-21
27193-26
235196P
SIGA-MP1
SIGA-MP2
SIGA-MP2L
20
iO Series
Intelligent Initiating Devices
SUBMIT
Releasing Module
Initiating
Devices
SW1-SW8
TB3
TB6
TB1
+
_
24 Vdc out
DS1
DS2
DS4
DS3
DS5
DS6 DS7
TB5
_
_
+
+
TB4 _
_
+
RELA-EOL
1
2
3
4
Release CCT1
RELA-EOL
1
2
3
4
Release CCT2
SIGA-REL
RELA-ABT
Abort station
RELA-SRV
276A-REL
278A-REL
RELA-EOL
Hazardous Location
Devices
Available releasing module accessories include dedicated pull stations, abort switches and service switches. Together with the SIGAREL, they comprise a complete fire suppression package.
24 Vdc in
Notification
Appliances
The releasing module includes a built-in timer that inhibits the deluge
function during the pre-action routine. One of four pre-action routines,
may be selected by means of dip-switches on the module. The
duration of automatic and manual time delays, as well as the abort
time settings are also selectable with dip-switches. The SIGA-REL
mounts inside an MFC-A cabinet or other suitable UL-listed electrical
enclosure. Each MFC-A will hold one SIGA-REL.
Signature data in
_
+
_
TB2
Door Holders
& Relays
21
iO Series
Intelligent Initiating Devices
AL
NORM
LIF
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
Signature Series
SIGA-270
SIGA-270P
276-K2
270-GLR
276B-RSB
TB2
REAR VIEW
Red LED
(Alarm/Active)
3 2 1
Green LED
(Normal)
TB1
DATA IN (+)
DATA IN (-)
TB2
Red LED
(Alarm/Active)
3 2 1
Green LED
(Normal)
TB1
DATA IN (+)
DATA IN (-)
To Next Device
SIGA-278
276B-RSB
276-GLR
RR-32RL
Stopper II
This unique device helps prevent false alarms without restricting legitimate ones. It consists of a tamperproof clear LEXAN polycarbonate shield and frame that fits easily over manual pull stations. When lifted,
it sounds a piercing warning horn.
STI-1100 (Flush)
STI-1130 (Surface)
STI-1200 (Flush)
STI-1230 (Surface)
Spacers
STI-3002 (Gasket)
Weatherproofing
22
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Notification
Appliances
Firefighters Telephones p. 31
Audible Signals p. 33
Accessories p. 34
+
+
retrofit+
-
- they
applications, these devices are durable, dependable, and virtually maintenance-free.
And
NAC1+
support a wide range of mounting options that make them ideal for
NAC2 +
NAC2
new
construction
+and
NAC2+
NAC2+
TB2
TB2
Class B wiring
Class B wiring
TB2
TB2
iO Series NACs may be individually configured for continuous, temporal, synchronized, and coded output.
TB6
TB6
Class A wiring
Class A wiring-
TB2
TB2
+
+
+
+
+
+
+
++
+
++
-
+
+
+
+
-
+
+
+
-+
-
EOLR
EOLR
EOLR
EOLR
Door Holders
& Relays
TB6
TB6
NAC1
NAC1 NAC1+
NAC1+
NAC2 NAC2 NAC2+
NAC2+
+
+
+
++
+
++
-
Hazardous Location
Devices
Notification
Appliances
applications alike.
EOLR
EOLR
23
iO Series
N o t i fi c a t i o n A p p l i a n c e s
iO Series
Intelligent Control
SUBMIT
Genesis Visual
& Audible Signals
A complete line engineered to
deliver innovative features and
superb output.
Initiating
Devices
Notification
Appliances
or simply retrofitting a local strip mall, competitivelypriced Genesis signals bring value, good looks, and
installation flexibility to every application. Contact Edwards today to learn how your signal solutions can be
the model of discretion.
24
iO Series
N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Genesis Series
Wall Strobes,
Horns & Chimes
Genesis signals feature textured housings in architecturally neutral white or
traditional fire red. An ingenious iconographic symbol indicates the purpose
of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak.
models with FIRE and ALERT markings are also available.
Genesis strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the
device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent
unauthorized tampering. (Data Sheet 85001-0573)
White housing
no marking
G1-VM
White housing
with FIRE
Red housing
no marking
G1F-VM
G1R-VM
G1F-V1575
Red housing
with FIRE
G1RF-VM
G1RF-V1575
White housing
no marking
White housing
with FIRE
Red housing
no marking
Red housing
with FIRE
G1-HD
G1F-HD
G1R-HD
G1RF-HD
G1-HDVM
G1F-HDVM
G1R-HDVM
G1RF-HDVM
G1RF-HDV1575
G1RF-P
G1F-HDV1575
G1-P
G1F-P
G1R-P
Hazardous Location
Devices
Notification
Appliances
Genesis Horns and Horn-strobes reach output levels as high as 99 dB and features a unique multiple frequency tone that
results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or noncoded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB.
(Data Sheet 85001-0573)
Genesis chimes and chime-strobes produce a pleasing mellow tone. When steady (non-stroked) voltage is applied, the
chime automatically pulses at 60 strokes per minute, or may be field-configured for temporal output. When installed with a
GIM Signal Master Module, the chime may also be field-configured for coded operation, which enables the chime output
to match the rate that voltage is applied to the circuit. Chimes may be set for low dB output with a jumper cut that reduces
sound output by about 5 dB. (Data Sheet 85001-0574)
White housing
Red housing
G1-CVM
G1R-CVM
G1-C
G1R-C
Trim plates for wall horns, chimes, and strobes are ideal for covering openings left behind during retrofits.
G1T
G1T-FIRE
G1RT
Red plate
White plateFire
with FIRE
with ALERT
G1RT-FIRE
G1WT-ALERT
Trim Plates
Door Holders
& Relays
White plate
White plate
Red plate
no marking
with FIRE
no FIRE
15/75 cd models provide fixed output. The 15 cd output component complies with UL1971. The 75 cd output component complies with UL 1638.
25
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Genesis Series
To change strobe to
(private mode) cut J
15
JP1
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
Bottom View
Wattage switch
Candela switch
Polarity shown in
alarm condition
S-
S+
SPKR
S-
S+
SPKR
Notification
Appliances
To next device
or end of line
device
All speakers feature selectable , , 1, or 2 watt operation. Multi-candela strobes feature selectable 15, 30, 75, or 110 cd output.
White housing
no marking
White housing
with FIRE
Red housing
no marking
Red housing
with FIRE
G4-S2
G4F-S2
G4R-S2
G4RF-S2
25 V Speaker
G4-S7
G4F-S7
G4R-S7
G4RF-S7
70 V Speaker
G4-S2VM
G4F-S2VM
G4R-S2VM
G4RF-S2VM
G4-S7VM
G4F-S7VM
G4R-S7VM
G4RF-S7VM
26
G4F-S7V1575
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Genesis Series
Ceiling Speakers,
Horns, and Strobes
The Genesis line of multi-candela and multi-wattage ceiling
signals feature all the hallmarks that have made Genesis
products a big hit with designers, engineers, building
owners, and installers everywhere. ESTs precision timing
electronics, and low current draw bring the benefits of the
popular Genesis wall-mount models to ceiling applications.
These signals are 30 per cent slimmer than comparable
signals on the market. They are compatible with standard
4-inch (10 cm) square electrical boxes and dont require
extension rings or trim plates. No mounting screws are
visible when the unit is installed, providing a clean, finished,
unobtrusive appearance that blends with any decor. These
signals are also listed for wall mount applications.
Fire Alarm Appliances
White housing
White housing
no marking
with FIRE
Red housing
with FIRE
Select
15/30/75/95
and 95/115/150/177
candela output!
Ceiling Strobes
Ceiling Horn-strobes
Ceiling Speaker-strobes
Ceiling Speakers
SUBMIT
Select
, , 1, or 2
watt operation!
GC-VM
GCF-VM
GCFR-VM
GC-VMH
GCF-VMH
GC-HDVM
GCF-HDVM
GCFR-HDVM
GC-HDVMH
GCF-HDVMH
GC-S2VM
GCF-S2VM
GC-S2VMH
GCF-S2VMH
GC-S7VM
GCF-S7VM
GC-S7VMH
GCF-S7VMH
GC-S2
GCF-S2
GCFR-S2
Speaker, 25 V
GC-S7
GCF-S7
GCFR-S7
Speaker, 70 V
Notification
Appliances
GCFR-S7VM
Hazardous Location
Devices
All speakers feature selectable , , 1, or 2 watt operation. All horns feature high or low dB output.
Multi-Candela Strobes feature 15, 30, 75, or 95 candela output. Multi High-Candela Strobes feature 95, 115, 150, or 177 candela output.
Door Holders
& Relays
27
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Genesis Series
Genesis Series
Outdoor Speakers
and Speaker-Strobes
Genesis WG4 Series speakers and speaker-strobes are among the most
versatile emergency signals of their kind. NEMA 4X rated for indoor or
outdoor use, they are suitable for a wide range of wet and harsh environments with a listed operating temperature range of as low as -31F to as
high as 151F (-35C to 66C).
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
Refer to Data Sheet 85001-0627 -- Genesis Outdoor Speakers and Strobes for details.
Field Configuration
SPKR SPKR +
STROBE STROBE +
Notification
Appliances
WG4RF-S
WG4RF-SVMC
WG4WF-S
WG4WF-SVMC
WG4RN-S
SPKR SPKR +
STROBE STROBE +
S3: Speaker
voltage
S1:
wattage
S2:
Candela
WG4RN-SVMC
WG4WN-S
White housing
no marking
White housing
with FIRE
Red housing
no marking
WG4WN-S
WG4WF-S
WG4RN-S
WG4RF-S
25/70 V Speaker
WG4WN-SVMC
WG4WF-SVMC
WG4RN-SVMC
WG4RF-SVMC
WG4WF-SVMHC
WG4RN-SVMHC
Red housing
with FIRE
WG4WN-SVMC
Trim skirts
28
WG4WTS (white)
WG4RTS (red)
iO Series
N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Genesis Series
Outdoor Horns
and Horn-Strobes
Genesis WG4 Series horns and horn-strobes are among the most versatile emergency signals of their kind. NEMA 4X rated for indoor or outdoor use, they are suitable for a wide range of wet and harsh environments with a listed operating temperature range of as low as -31F to as high as 151F (-35C to 66C).
Refer to Data Sheet 85001-0628 -- Genesis Outdoor Horns and Strobes for details.
Field Configuration
Signal In
Signal Out
Signal In +
Signal Out +
Genesis WG4 strobes feature four selectable light output settings. Cd selections are changed by removing the cover and
simply sliding the switches to the desired setting, which remains
visible through a small window on the front of the device after the
cover is replaced. Genesis Horn-strobes may also be
configured for high or low dB output and temporal flash. This
battery-saving feature is intended for private mode signaling only.
WG4RF-H
WG4RF-HVMC
WG4WF-H
WG4WF-HVMC
WG4RN-H
WG4RN-HVMC
WG4WN-H
Notification
Appliances
WG4WN-HVMC
Light Output
Standard Candela Horn-strobes
UL 1971
UL 1638
CAN/ULC-S526
Indoor
Outdoor @ -35C
Outdoor @ -40C
Standard/rating
UL 1971
UL 1638
CAN/ULC-S526
Indoor
Outdoor @ -35C
Outdoor @ -40C
White housing
no marking
White housing
with FIRE
Red housing
no marking
Red housing
with FIRE
WG4WN-H
WG4WF-H
WG4RN-H
WG4RF-H
Horn Only
WG4WN-HVMC
WG4WF-HVMC
WG4RN-HVMC
WG4RF-HVMC
WG4WN-HVMHC
WG4WF-HVMHC
WG4RN-HVMHC
Hazardous Location
Devices
Standard/rating
Door Holders
& Relays
WG4WTS (white)
WG4RTS (red)
74347U (white)
449 (red)
WG4GSKT
29
iO Series
N o t i fi c a t i o n A p p l i a n c e s
iO Series
Intelligent Control
SUBMIT
Strobe Circuit
EOLR
120
VAC
F
I
R
E
EOLR
TB1 1
8
TB2
TB3
11
10
Initiating
Devices
8
7
4
5
Trouble
Normal
Alarm
1 2 3 4 5 6 7 8
12 V
Battery
Notification
Appliances
F
I
R
E
1 2 3 4 5 6 7 8
12 V
Battery
Panels include DMR, temporal pattern, standard message, microphone, power supply and battery charger.
ANS100MDR (Red Cabinet) 100 Watt Audio Notification Panel. Data Sheet 85001-0587
Panels include power supply and battery charger. DMR and microphone ordered separately.
ANSAUX
ANSBKUP
ANSBKUPA
ANSDMRALT
ANSDMRCUSTOM
ANSMIKE
ANSREMG
ANSREMR
ANSREMSUP
ANST28180
Audio Evacuation Accessory, Power Transformer 50/100W Systems Data Sheet 85001-0587
ANST2885
ANSZC2B
ANSZS2A
ANSZS4B
ANSZSC4A
ANSZSR
30
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Firefighters
Telephones
Four-state operation
Compatible signal
module.
Telephone
riser
Normal
(on hook)
SUBMIT
Active
(off hook)
Firefighters telephones are typically installed in corridors, lobbies, mechanical rooms, stairways, or other stategic locations.
When lifted from its cradle, or plugged into a suitable wall jack,
the handset activates audible and visible signals at the IO Series
control panel.
2
4
5
24 Vdc
24 Vdc
UL/ULC listed
power supply
Edwards fire alarm telephones are rugged communications devices for emergency use. Enclosed keylocked telephone stations
comprise three separately ordered components: the handset
assembly, the frontplate, and the wallbox. Depending on how
the phones are wired, they are supervised for three or four state
operation. Frontplates are available with either metal or break
glass insterts.
MEA approved warden stations feature doors with magnetic
latches and one-state handsets with armoured cords. Warden
stations mount to 6832-1 wallboxes. Portable handsets plug into
one-gang receptacles. Handsets are available in black or red. The
TCS-6 cabinet provides storage for up to six handsets.
47 kW
TB1
Three-state operation
Compatible signal
module.
Normal
(on hook)
Telephone riser
1
2
3
47 kW
4
5
24 Vdc
24 Vdc
UL/ULC listed
power supply
TB1
Notification
Appliances
6833-1
6830-NY-S
6831-1
6831-4
6832-1
6830-1
6830-3
Firefighters Telephones
Four-state Remote Telephone Warden Station - Surface. Armored armored cord.
6830-NY-F
6830-5A-4
Four-state Telephone Handset Assembly - Red, 60 (1500mm) Coiled Cord, Push-to-talk button.
6830-6A-4
Four-state Telephone Handset Assembly - Red, 60 (1500mm) Armored Cord, Push-to-talk button.
6830-1
6830-4
6830-5A
Three-state Telephone Handset Assembly - Red, 60 (1500mm) Coiled Cord, Push-to-talk button.
6830-6A
Three-state Telephone Handset Assembly - Red, 60 (1500mm) Armored Cord, Push-to-talk button.
6833-4
6833-1
6830-3
6700-0061
6831-1
Frontplate - Flush Mount, Red Finish, Break Glass Type c/w 2 keys.
6831-2
Frontplate - Flush Mount, Red Finish, Non-Break Glass Type c/w 2 keys.
6831-3
Frontplate - Surface Mount Red Finish, Break Glass Type c/w 2 keys.
6831-4
Frontplate - Surface Mounting Red Finish, Non-Break Glass Type c/w 2 keys.
6832-1
Wallbox - Flush or Surface mount, Red finish. 14 (356mm) H x 8-1/2 (216mm) W x 3 (89mm) D.
TCS-6
Portable handset storage cabinet. Surface mount c/w keylock. Red finish with white lettering.
Door Holders
& Relays
6830-NY-S4
Hazardous Location
Devices
6830-NY-F4
31
iO Series
N o t i fi c a t i o n A p p l i a n c e s
iO Series
Intelligent Control
SUBMIT
North American
2-gang electrical box
Mounting Plate
Harsh Environment
Signals
Housing
Single Captive Mounting Screw
First Device
All Enhanced Integrity devices are UL 1971 listed for both wall and ceiling orientation. Enhanced Integrity strobes meet the latest UL1971 synchronization requirements when used with the G1M Signal Master. Integrity devices are shipped
with wall mount style FIRE lens markings. Other lens markings are available.
Initiating
Devices
To Fire Alarm
Control Panel
Signal Circuit
+
Horn/Strobe
H+
HS+
S-
Horn/Strobe
H+
HS+
S-
Notification
Appliances
15/75 cd
30 cd
110 cd
757-7A-RS25
757-7A-RS70
757-3A-RS70
757-8A-RS25
Speaker only
757-3A-RS25
757-8A-RS70
757-1A-R25
757-1A-R70
757-1A-T (Red)
757-7A-T (Red)
757-4A-T (Red)
757-8A-T (Red)
405-5A-T (Red)
405-5A-TW (White)
Strobe - 15 cd
405-7A-T (Red)
405-7A-TW (White)
Strobe - 15/75
405-3A-T (Red)
405-3A-TW (White)
Strobe - 30 cd
405-6A-T (Red)
405-6A-TW (White)
Strobe - 60 cd
405-8A-T (Red)
405-8A-TW (White)
Strobe - 110 cd
32
To Next Device
or EOL Resistor
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Audible Signals
SUBMIT
323D-10AW (Grey)
323D-10AR (Red)
439D-6AW (Grey)
439D-6AR (Red)
439D-10AW (Grey)
439D-10AR (Red)
5530MD-24AW
Notification
Appliances
Multi-purpose Loudspeaker
The HPSA15 loudspeaker is a high-efficiency double re-entrant loudspeaker that operates within a
nominal frequency response range of 400-14,000 Hz, and provides audible output of 120 dB (peak
at one meter) at the rated power level. It includes a versatile, three-way, 25/70.7 V line transformer
that meets a variety of distributed system needs. The transformer is adjustable by means of a
convenient seven-position, watts/impedance selection switch.
15-watt loudspeaker, red
HPSA15G2570
Hazardous Location
Devices
HPSA15R2570
Accessories
Signal Master
G1M
G1M-RM
Snap-on
(piggyback) model
Remote 1-gang
mount model
Door Holders
& Relays
The Signal Master is a simple-to-use accessory that adds enhanced features to Genesis and Integrity strobes and Horn-Strobes. It is a dual-purpose
module that provides UL 1971 required precision synchronization for connected Integrity and Genesis strobes, and independent control for connected
Genesis Horns over a single pair of wires. Two methods of Horn control are
available: traditional Horn silence; or, normally-closed contact. Both methods
may be used to silence Horns without turning off strobes on the same circuit.
Two models are available. The Genesis piggyback model doesnt require a
separate electrical box. It simply snaps to the back of the first G1 signal on the
circuit. The remote mount model mounts in a North American 2 inch (64 mm)
deep one-gang box.
33
iO Series
N o t i fi c a t i o n A p p l i a n c e s
Accessories
Bell/Strobe Plate
The bell/strobe plate is ideal for renovation and retrofit projects, and new construction. It
is equipped with an Edwards self-synchronizing strobe and is designed to allow on-site
mounting of the 439 series Vibrating Bell, providing instant conversion to Bell/Strobe
audible/visual signal appliances. The strobe is designed for 20 to 24Vdc operation and
must be connected to signal circuits which output a constant (not pulsed) voltage. A
diode is used to allow full signal circuit supervision.
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
Notification
Appliances
403-5A-R (15 cd) 403-7A-R (15/75 cd) 403-3A-R (30 cd) 403-8A-R (110 cd)
Mounting Accessories
Integrity Temporal Horn, Horn/strobe
757A-SB
Surface Box, Red, Indoor
757A-SBW Surface Box, White, Indoor
757A-WB Weatherproof Box, Red, Surface
757A-WBW Weatherproof Box, White, Surface
Integrity Speakers, Speaker/strobes
960A-4SF Flush Box, Indoor
757A-SB
Surface Box, Red, Indoor
757A-SBW Surface Box, White, Indoor
Integrity Re-entrant speakers, Speaker/strobes
960A-4SF Flush Box, Indoor
757A-SB
Surface Box, Red, Indoor
757A-SBW Surface Box, White, Indoor
757A-WB Weatherproof Box, Red, Surface
757A-WBW Weatherproof Box, White, Surface
Integrity Chimes, Chime/strobes
757A-SB
Surface Box, Red, Indoor
757A-SBW Surface Box, White, Indoor
34
Genesis Signals
27193-11 Horn-strobe Surface Box, Red, Indoor
27193-16 Horn-strobe Surface Box, White, Indoor
G4RB
Speaker Surface Box, Red, Indoor
G4B
Speaker Surface Box, White, Indoor
G4ERB
G4 Dual-strobe Format Surface box, Red
G4EWB
G4 Dual-strobe Format Surface box, White
Horn/siren Combination
349
Weatherproof Backbox
Fire Alarm Bells and CS-405 Series
449
Weatherproof Backbox
iO Series
Hazardous Location Devices
Hazardous
Location Devices
Initiating Devices p. 36
Notification Appliances p. 37
Edwards hazardous location devices provide reliable life safety protection and emergency signaling in areas where
atmospheres could become harsh or explosive. All hazardous location devices are UL rated under the full range of
classifications set out in the National Electrical Code.
The following classification definitions are an interpretive summary based on the 1996 edition of the National Electrical Code (NEC, NFPA 70). Refer to the latest editions of NFPA 497M, NFPA 70 and the UL Hazardous Location
Equipment Directory for current and more detailed information. For more information on NEMA classifications, refer
to NEMA Standards Publication No. 250.
Class III - Hazardous Fibers. Class III locations have easily ignitable
fibers or flyings present, but not likely to be suspended in air in quantities
sufficient to produce ignitable mixtures in the atmosphere.
Groups
Door Holders
& Relays
Hazardous Location
Devices
Divisions
Group F. Atmospheres containing combustible carbonaceous dusts, including carbon black, charcoal, coal, or dusts
that have been sensitized by other materials so that they
present an explosion hazard.
Group G. Atmospheres containing combustible dusts not
included in Group E or F, including flour, grain, wood, plastic,
and chemicals.
35
iO Series
Hazardous Location Devices
iO Series
Intelligent Control
SUBMIT
Initiating Devices
Rate Compensation Heat Detectors
Series 302 heat detectors are designed for use in normal environments as well as environments
where the detectors are subject to weather, moisture (internal condensation), and explosive
atmospheres. They are normally-open devices designed to close an electrical circuit upon
activation. All models feature rate compensation and are available with either 135 F (57.2 C)
or 194 F (90 C) ratings. They are self restoring, hermetically sealed, shock and corrosion
resistant, and are tamperproof.
Initiating
Devices
Surface
Mount
Hazardous Location
Devices
Notification
Appliances
Box
mount
Sensors Rated
Temperature
Minimum Ambient
Air Temperature
Maximum Ceiling
Temperature
135 F (57.2 C)
194 F (90 C)
-40 F (-40 C)
-40 F (-40 C)
100 F (38 C)
150 F (66 C)
The sensor's aluminum tube acts as a heat collector when sources of heat radiate directly
on the tube. Install these sensors out of direct sunlight and away from radiating heat sources
including the direct flow from heaters and heat ducts.
302-AW-135 All-weather Heat Detector - Vertical Mounting FM & UL, 135 F (57.2 C)
302-AW-194 All-weather Heat Detector - Vertical Mounting FM & UL, 194F (90 C)
302-ET-135
All-weather Heat Detector - Vertical, Box Mount (" NPT), FM & UL, 135 F (57.2 C)
302-ET-194
All-weather Heat Detector - Vertical, Box Mount (" NPT), FM & UL, 194F (90 C)
AP-P
Adaptor plate for mounting 302 and 302-AW to any 3" box or 4" octagon outlet box Data Sheet: 85001-0589
STONCO27
JALX11
MPSR1-DHTWX-GE
MPSR1-D45WX-GE
Manual Stations
MPSR1-SHTW-GE
MPSR1-S45W-GE
MPSR1-DHTW-GE
MPSR1-D45W-GE
MPSR2-SHTW-GE
MPSR2-S45W-GE
MPSR2-DHTW-GE
MPSR2-D45W-GE
MPSR2-SHTW-GE-NYW
For French markings add -F to the suffix of the model number. For bilinguial French/English markings add -B to the suffix of the model number.
36
MPSR-LP
MPSRGR10
276-K1
iO Series
Hazardous Location Devices
SUBMIT
Notification Appliances
Hazardous Location Strobes
Class I, II, or III locations
116DEGEX-FJ hazardous location strobes are life safety signaling appliances designed for installation in
hazardous environments. State-of-the-art technology provide for high visual output and low maintenance.
The 116DEGEX-FJ has negligible in-rush current. When pendant, wall or ceiling mounted, the 116DEGEXFJ meets or exceeds the requirements of UL 1971 Signaling Appliance for the Hearing Impaired.
116DEGEX-FJ
116EX-B
116EX-C
116EX-P
116-GRD
Lens Guard
430D series of hazardous location bells are diode-polarized, heavy duty fire bells for use in life safety applications
where a diode supervised signal is required. They can be mounted to any solid surface using two 3/8 inch (10 mm)
bolts and the supplied mounting brackets or to a rigid conduit. The integral explosion-proof housing is mechanically
terminated to accept a standard 3/4 inch -14 National Pipe Taper (NPT) nipple.
439DEX-6AW (6)
439DEX-8AW (8)
439DEX-10AW (10)
Bell 24 Vdc
438DEX-6N5 (6")
438DEX-8N5 (8")
438DEX-10N5 (10")
Hazardous Location
Devices
888D and 889D hazardous location horns are diode-polarized, heavy duty, high decibel vibrating horns intended for
use in life safety systems in hazardous (classified) locations. These horns may be mounted to any solid surface using
two bolts. Each unit is supplied with a sealing fitting for a 3/4 inch -14 National Pipe Taper (NPT) nipple, and wire leads
for the electrical connection to the life safety system notification appliance circuit.
Door Holders
& Relays
37
iO Series
Door Holders & Relays
Hazardous Location
Devices
Door Holders
24 Vdc
120 Vac 60 Hz
Floor Mounted
1508-AQN5 (Surface)
Wall Mounted
Catch Plate
Catch Plate
CS2595-5 (short)
CS2598-5 (long)
Replacement Armature
Relays
Door Holders
& Relays
Edwards electromagnetic door holders keep doors open until signaled by the
fire alarm system, a heat detector, a smoke detector, or an electrical switch.
Door holders should be installed wherever doors may be effectively used to
confine smoke and fire, or where the release of a self-closing door from a
remote location is required. Fail-safe operation is an inherent feature of these
door holders. If power fails, doors are released automatically, but may be
opened or closed manually at any time. All units are free of moving parts, are
self-contained, and require no maintenance. Door holders have a holding force
of approximately 15-25 Lbf (66-111N).
24 Vac 60 Hz
Notification
Appliances
Initiating
Devices
iO Series
Intelligent Control
SUBMIT
38
iO Series
Door Holders & Relays
SUBMIT
SPDT Relays
Single-pull/double-throw relays are ideal for applications where local or remote contacts are required for control of electrical loads. They are suitable for use with HVAC,
temperature control, fire alarm, security, energy management, and lighting control
systems. Each relay position contains a high-intensity LED which, when illuminated,
indicates the relay coil is energized. Individual relay circuits may be snapped apart
from standard four- or eight-position modules, and are also available in a single-circuit
configuration. The common power to each relay position is bussed on the printed
wiring board, which permits power to be connected only once per multi-position
module.
Door Holders
& Relays
PAM-1
39
Proven leadership.
Proud heritage.
Shared vision.
installed an electrically-operated
uncompromised excellence.
Innovation, leadership,
and a rich tradition of excellence
Whether EST life safety systems are protecting the lives and livelihoods of the
people who make businesses run, or the lives entrusted to the care of public
institutions; whether theyre charged with protecting the guests of the worlds
finest hotels, or preserving irreplaceable artifacts that bring history to life; EST
stands alone as the brand closely associated with some of the most important
and far-reaching developments in the life safety industry today.
Our strength is in our Strategic Partners the people and organizations
we entrust with the technology that has charted the course of life safety protection for decades. Strategic Partners are not middlemen or go-betweens. They
are independent contractors that form an integral part of the Edwards marketing
and support organization. As insiders, they enjoy exclusive access to products,
custom design innovations, specialized training, and factory direct pricing. Yet
as successful independent contractors, they are adept at ensuring that each
submittal is strong and competitive, and that each bid is locally relevant to your
installation. As local businesses they not only have to earn your trust they
have to keep it.
Together these strengths set EST installations apart, and have earned this
brand a special place among life safety and security solutions available today.
Perhaps thats why EST products and systems have become the choice of
building owners, architects and engineers around the globe. And why many of
the worlds most cherished landmarks are protected by Edwards products that
bear the EST mark. From the Bibliotheca Alexandrina Museum in Egypt, to the
modern-day sphinx at the Luxor Hotel in Las Vegas, professionals who design,
own and occupy the worlds most impressive structures have come to know
that the safest and most survivable solution today is an EST solution.
Contact us...
Email: edwards.fire@fs.utc.com
Web: www.est-fire.com
Partner today.
85005-0132 Issue 2
07-31-13