You are on page 1of 6

Traders & Exporters of Power Equipments and Power Consultancy

Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
Ref : LIPS/ABB/Quo/780 July 26, 2014
M/s ABB Ltd,
Shore 2 Ship Power Solutions
Plot Nos 5 & 6 2nd Phase Peenya
560058, Bangalore, Karnataka, INDIA
Phone: +918022948138
Mobile: +919731922388
Kind Attn: Mr. MITHUN SHENOY POWER SYSTEMS (T&D INFRASTRUCTURE SS)
Subject: YOUR REQUIREMENT OF 110KV/33KV ELECTRICAL ITEMS FOR YOUR POOLING STATION &
SHIRAHATTI BAY EXTENSION WORKS - YELISIRUR PHASE 2 PROJECT.
Dear Sir,
We thankfully acknowledge the receipt of your email enquiry dated 25-02-2014 regarding your requirement of
110KV/33KV Electrical Items for your Pooling Station & Shirahatti bay extension works - Yelisirur phase 2 Project.
We are pleased to submit our lowest OFFER for the same on the terms and conditions as under:
PRICES : The quoted Prices shall be FIRM & Variable for Cables, Conductors & Transformers.
SCHEDULE OF QUANTITY AND PRICES ( BOUGHTOUT ITEMS)
Name of Bidder LUCKY INDIA POWER SOLUTIONS, GHAZIABAD
Sr.
No
DESCRIPTION Unit Qty UNIT EX
WORKS
PRICE
(Rs.)
ED
@10.30%
CST
@2%
Unit Frt
Charges
(Rs.)
Unit
Total
Prices
(Rs.)
Total
FOR
Prices
(Rs.)
110KV & 33KV Outdoor equipment at
pooling station
A 110KV EQUIPMENT
1 Circuit Breakers with mounting structures. Nos. 3 696350 0 13927 0 710277 2130831
2
Current Transformers (Single Phase) as per SLD
Nos. 9 130800 13472 2885 0 147158 1324421
3
Potential Transformers Electromagnetic type
(Single Phase) as per SLD.
Nos. 4 125400 12916 2766 0 141083 564330
4
Isolators with earth switch (pole to pole spacing
2700mm)
No. 1 199450 0 3989 0 203439 203439
5
Isolators without earth switch (pole to pole
spacing 2700mm)
Nos 3 202800 0 4056 0 206856 620568
6 Lightning arrestors with surge monitor Nos 9 55800 0 1116 0 56916 512244
7
2.5 inches Standard Tubular aluminium busbar
Mtrs 300 47260 0 945 0 48205 14461560
8 Drake ACSR conductor strung bus Mtrs 100 340 0 7 0 347 34680
9 Bus post insulator assembly Sets 6 7750 0 155 0 7905 47430
10
Clamps & connectors for all the equipments,
General hardware, etc.
Lot 1 294900 0 5898 0 300798 300798
11
Marshalling box for current transformers (One
each for Line CT and transformer CT)
Nos 3 5500 567 121 0 6188 18563
12
Marshalling box for potential transformers (One
each for line PT, and bus PT)
Nos 2 5500 567 121 0 6188 12376
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
13 12 mtr lightning pole Nos 5 15500 0 310 0 15810 79050
14 GI Structures with hardware.
15 Line gantry structure MT 17 83000 8549 1831 0 93380 1587460
16 Equipment mounting structures MT 7 83000 8549 1831 0 93380 653660
B 33KV EQUIPMENT
1
33kV 800 A, Outdoor Breakers with mounting
structure
Nos. 6 231500 0 4630 0 236130 1416780
2
33kV Current Transformers
Nos. 18 17000 1751 375 0 19126 344268
3
33kV Potential Transformers
Nos. 6 15500 1597 342 0 17438 104631
4
33kV Lighting Arrestor
Nos. 24 14500 0 290 0 14790 354960
5
33kV Isolator with Earth switch
Nos. 4 69900 0 1398 0 71298 285192
6
33kV Isolator without Earth switch
Nos. 9 59500 0 1190 0 60690 546210
7
LYNX ACSR conductor (connection to 33kV
equipments and Main bus conductor)
Mtr. 500 167 0 3 0 170 85170
8 GI Structures
a) Terminating Structure for line Termination &
interconnecting busbar
MT 40 83000 8549 1831 0 93380 3735199
b) Equipment mounting Structures MT 15 83000 8549 1831 0 93380 1400700
c) Support structure for Aux. transformer MT 1.2 83000 8549 1831 0 93380 112056
9
Clamps, bus insulator, String insulator, connectors
etc.
Lot 1 144500 0 2890 0 147390 147390
10
Marshalling box for Current transformers &
Potential transformers.
Nos. 8 4200 433 93 0 4725 37802
11
100 mm dia PVC Pipes for taking cables to the
trench
Lot 1 237 0 5 0 242 242
12
50 mm dia PVC Pipes for taking cables to the
trench
Lot 1 102 0 2 0 104 104
C TRANSFORMERS AT POOLING STATION
1
28000/20000 KVA transformer with accessories
complete and cooling fan control panel, as per
specifications.
Set 2 24090375 2481309 531434 0 27103117 54206235
2
Loose items to be supplied as per specifications
(such as WTI, OTI, Remote Tap position indicator
etc.,) for 20000/28000 KVA Transformer.
Lot 2 3125000 321875 68938 0 3515813 7031625
3
63 KVA transformer with accessories complete as
per specifications.
Nos 2 126900 13071 2799 0 142770 285540
D
POWER CABLES AND CABLE SUPPORT ANGLES
FOR 110KV OUTDOOR SWITCHYARD AT POOLING
STATION
1
LT Power cable of 1.1KV grade, 3.5Core x 95 sqmm
aluminium armoured cable **
Mtr. 100 317 0 6 0 323 32334
2 Control cables as below **
2.1 2C x 2.5sqmm, armoured, copper cable Mtr 350 53 0 1 0 54 18921
2.2 4C x 4sqmm, armoured, copper cable Mtr 3000 133 0 3 0 136 406980
2.3 4C x 6 sqmm, armoured, copper cable Mtr 400 192 0 4 0 196 78336
2.4 7C x 2.5 sqmm, armoured, copper cable Mtr 800 174 0 3 0 177 141984
2.5 19C x 2.5 sqmm, armoured copper cable Mtr 500 402 0 8 0 410 205020
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
3
Cable terminations for the following with glands.
3.1 Control cables No. 650 1142 0 23 0 1165 757146
3.2 LT Power cables No. 2 1035 0 21 0 1056 2111
4 Cable supporting angles MT 4 75 8 2 0 84 338
E
110V BATTERY AND BATTERY CHARGER AT
POOLING STATION
1
110V,battery bank, battery charger and integral
DCDB with all accessories complete as per
specification
No. 1 493950 0 9879 0 503829 503829
F
415 V AC DISTRIBUTION BOARD AT POOLING
STATION
1
415 V AC distribution board for station
arrangement
No. 1 150400 0 3008 0 153408 153408
G
Earthing of 110KV Outdoor switchyard at Pooling
Station
1
Earth mat at Pooling station switchyard by
50x6mm MS flats
Mtr 2500 194 0 4 0 198 494700
2
50x6mm GI Strip conductor for earthing of all
equipment/ structure in switchyard.
Mtr. 500 194 0 4 0 198 98940
3 Treated Earth pits with Test links Nos 100 32250 0 645 0 32895 3289500
4 Treated Earth pits with out Test links Nos 50 8150 0 163 0 8313 415650
5 Risers in switch Yard Area (50x6 GI) Mtr 600 370 0 7 0 377 226440
6 Lightting Conductors (50x6 GI) Mtr 135 0 0 0 0 0 0
7 450 mm Dia concrete Earth rings for Earth pits Nos 150 0 0 0 0 0 0
H
CONTROL, RELAY & METERING PANELS AT
POOLING STATION
1 110 kV Transmission Line Relay Panel No. 1 596500 0 11930 0 608430 608430
2 Transformer control relay panel No. 2 716600 0 14332 0 730932 1461864
3 33KV Line relay panel No. 4 210500 0 4210 0 214710 858840
A 110 KV Equipment
1
Line Isolator with earth switch (pole to pole
spacing 2700mm)
No. 1
202800 0 4056 0 206856 206856
2
Bus Isolator without earth switch (pole to pole
spacing 2000mm)
No. 1
199450 0 3989 0 203439 203439
3 Circuit Breaker with mounting structure No. 1 696350 0 13927 0 710277 710277
4 Voltage Transformer (single phase) Nos. 3 125400 12916 2766 0 141083 423248
5 Current Transformers (single phase, four core) Nos. 6 130800 13472 2885 0 147158 882947
6 Lightning arrestors with Surge Monitor Nos 3 55800 0 1116 0 56916 170748
7 Bus post insulator assembly Nos 3 7750 0 155 0 7905 23715
8
110 kV Transmission Line Control & Relay Panel No. 1
596500 0 11930 0 608430 608430
9 Drake ACSR conductor ( strung bus) Mtrs 250 340 0 7 0 347 86700
10
String insulators, Clamps & connectors for all the
equipments and conductors, General hardware,
etc.
Lot 1
294900 0 5898 0 300798 300798
11 Marshaling Box for CT, PT Nos. 3 5500 567 121 0 6188 18563
12
100mm dia Class B type, GI pipes with elbows, T-
bends etc., for equipment cabling from
marshalling box to cable trench.
Kgs 300
237 0 5 0 242 72522
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
13 PVC Pipe for cabling Mtr. 320 310 0 6 0 316 101184
14 GI Structures including hardwares
15 Line gantry structure MT 2 83000 8549 1831 0 93380 186760
16 Equipment mounting structures MT 3 83000 8549 1831 0 93380 280140
17 Bus Gantry structure MT 2.5 83000 8549 1831 0 93380 233450
18 Hume pipes of 150 mm dia for cabling Mtr. 100 0 0 0 0 0 0
19 50 mm GI Pipe For TVN Cable Mts 50 102 0 2 0 104 5202
B
Earthing of 110KV Outdoor switchyard
extensions at Shirahatti KPTCL S/S
1
Earthmat & Earthing of all equipments at
Switchyard extension and earthing of control
panels
1.1 Treated earth pits with test links Nos. 6 32250 0 645 0 32895 197370
1.2 Treated earth pits without test links Nos. 2 8150 0 163 0 8313 16626
1.3 Earth mat conductor 50x6mm(GI) Mtr. 300 194 0 4 0 198 59364
1.4
50x6mm GI Strip conductor for earthing of all
equipment/structure in switchyard extension and
earthing of control panels.
Mtr. 400
194 0 4 0 198 79152
1.5 450 mm dia Concrete earth rings for earth pits Nos 8 0 0 0 0 0 0
C
CONTROL & RELAY PANELS at Shirahatti KPTCL
S/S
1 110 kV Transmission Line Relay Panel No. 1 596500 0 11930 0 608430 608430
2
TVM outdoor cubicle with 2 Nos TVM of 0.2 class No. 1
0 0 0 0 0 0
D
POWER & CONTROL CABLES AND CABLE
SUPPORT ANGLES FOR 110KV OUTDOOR
SWITCHYARD EXTENSION AT Shirahatti KPTCL
SUBSTATION
1 Control cables as below **
1.1 2C x 2.5sqmm, armoured, copper cable Mtr. 350 53 0 1 0 54 18921
1.2 4C x 4sqmm, armoured, copper cable
Mtr. 350 133 0 3 0 136 47481
1.3 4C x 6sqmm, armoured, copper cable Mtr. 200 192 0 4 0 196 39168
1.4 7C x 2.5sqmm, armoured, copper cable Mtr. 640 174 0 3 0 177 113587
1.5 19C x 2.5sqmm, armoured, copper cable Mtr. 360 402 0 8 0 410 147614
2
Cable terminations for the following with glands
2.1 Control cables Lot 1 1142 0 23 0 1165 1165
2.2 LT Power cables Lot 1 1035 0 21 0 1056 1056
E
SPARES FOR 110KV OUTDOOR EQUIPMENT At
Shirahatti KPTCL S/S
1
Trip coil for Circuit breaker at KPTCL S/S (each
type)
set 2
7850 0 157 0 8007 16014
2
Close coil for Circuit breaker at pooling station
(each type)
set 2
7850 0 157 0 8007 16014
3 PT (1 Phase) (each type) set 1 147800 15223 3260 0 166284 166284
4 CT(1 Phase) (each type) set 1 140900 14513 3108 0 158521 158521
5
One pole of Isolator with tandem pipe, operating
rod, main blade & earthing blade.
Set 1 0 0 0 0 0 0
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
6 Control fuses (20% of qty used in) Set 1 5400 0 108 0 5508 5508
7 HV insulators (each type) set 2 0 0 0 0 0 0
8 Limit switches (each type) set 1 0 0 0 0 0 0
9 Clamps & Connectors (each type) set 2 0 0 0 0 0 0
10 LA with surge monitor No. 1 70500 0 1410 0 71910 71910
11
ACSR conductors/Tubular bus bars (20% of qty
used in)
Mtrs 1
0 0 0 0 0 0
F
SPARES FOR CONTROL AND RELAY PANEL AT
Shirahatti KPTCL SUBSTATION
1 Ammeter (each type) set 1 0 0 0 0 0 0
2 Voltmeter (each type) set 1 0 0 0 0 0 0
3 Timer No, 1 0 0 0 0 0 0
4 Wattmeter No. 1 0 0 0 0 0 0
5 Var meter No. 1 0 0 0 0 0 0
6 Indicating Lamps Nos. 6 0 0 0 0 0 0
7
Selector switches and push buttons (each type) set 1
0 0 0 0 0 0
8 Semaphore indicators (each type) set 1 0 0 0 0 0 0
9 Breaker Control switch (each type) set 2 0 0 0 0 0 0
10 Aux. Relay (each type) set 1 0 0 0 0 0 0
11 Trip relay No. 1 0 0 0 0 0 0
12 Annunciator No. 1 0 0 0 0 0 0
13
Aux VT of ratio 110V/root 3/110V/root 3, Class 3P,
25VA per phase
No. 1
0 0 0 0 0 0
14
Protective relays except Distance relay (each type) set 1
0 0 0 0 0 0
16
Terminal Connector for 110KV CTs/PTs Nos 1 900 0 18 0 918 918
18
Terminal Connector for 33KV CTs/PTs Nos 1 690 0 14 0 704 704
TOTAL 35901910 2972647 777491 0 39652048 108681070
YOU WILL BE GLAD TO KNOW THAT WE HAVE STARTED OUR OWN MANUFACTURING OF ALL TYPES OF CTs/PTs/CTPT
UNITS/METERING CUBICLES/LTCT/RVT RESIN CAST / OIL COOLED, INDOOR / OUTDOOR, DEAD TANK / LIVE TANK UPTO THE
SYSTEM VOLTAGE OF 33KV CLASS BY THE NAME OF MINI ENGINEERING WORKS AT GHAZIABAD AND ABOVE 33KV TO
400KV CLASS WE BECAME CHANNEL PARTNER OF MEHRU ELECTRICAL & MECHANICAL ENGINEERS PVT. LTD, BHIWADI.
APART FROM MANUFACTURING OF CTs/PTs, WE ALSO STARTED MANUFACTURING OF ALL TYPES OF DISTRIBUTION BOXES,
TRANSFORMER PROTECTION BOXES, METER BOXES, ALL TYPES OF ENCLOSURES. WE ARE ALSO ENGAGED IN ALL TYPES
OF HEAVY FABRICATION AS PER CUSTOMER REQUIREMENT(S) AS PER THEIR DRAWING.
KINDLY NOTE THAT WE CAN SUPPLY YOU SUBSTATION COMPLETE MATERIALS UPTO 400KV INCLUDING COMPLETE
SUBSTATION / PLANT AUTOMATION SYSTEM BY SCADA, PLC. YOU ARE, THEREFORE, REQUESTED TO KINDLY SEND US
COMPLETE BOQ SO TO SEND YOU OUR BEST & COMPETITIVE OFFER ALONGWITH BEST QUALITY MATERIALS TOO.
Traders & Exporters of Power Equipments and Power Consultancy
Info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com
+91-986 866 7484
+91-975 938 1998
+91-1232-226182
F-285, Phase-I, UPSIDC, Khichra Industrial Area, Masoori Gulawati Road, Ghaziabad-201001, UP, India
COMMERCIAL TERMS
1. PRICES: Prices quoted are net ex our works at various location from India.
2. EXCISE DUTY: NIL and 10.3% extra for CTs/PTs/JBs/Terminal Connectors/Structures, since, these shall be billed through our
Manufacturing unit Mini Engineering Works, Ghaziabad and PO shall be in its favour for above items to excise purpose.
3 The prices quoted by us are variable as per standard IEEMA FORMULA without any ceiling. The base date will be as on 01/06/2014
3. SALES TAX: 2% against form C for dispatch outside U.P. 14.0% VAT within U.P. If form C is not available, then full rate of tax will
be applicable as per sales tax rules.
4. DELIVERY: As per your delivery schedule.
5. PAYMENTS: 20% as advance along with order; and balance 80% alongwith full taxes and duties against Proforma
Invoice before dispatch.
6. VALIDITY: Offer is valid for a period 30 days from the date of our Offer.
7. PRICE ESCALATIONS: The prices have been quoted after taking into account prevailing discounted rates of the switchgear suppliers
mentioned in Bill of Material as on the date of this offer. Any subsequent increase in the rates of these switchgears on account of
price revisions or increase in taxes / duties / levies shall be charged extra to your account.
8. WARRANTEE: 18 months from the date of dispatch or 12 months from the date of commissioning of Transformer, whichever is earlier
under normal working condition.
9. INSPECTION & TESTING: Final testing of control panels shall be carried out at our works. We would welcome the deputation of your
authorized representative for witnessing the final testing at our works with prior appointment at mutually convenient schedules.
10. Form C or any other applicable form shall be submitted at the time of taking delivery. If the form is not submitted then difference of
Tax amount shall be kept as a deposit until we receive the Form.
11. TEST: All routine Tests as per IS-2026 will be carried out on the transformers at our works. If any special or type tests are required then
that will be extra at actual.
12. FREIGHT: Freight shall be charged extra as per actuals.
13. PACKING: Shall be charged extra @ 4%.
14. Our Offered items are strictly as per your technical specification, hence, no deviation.
15. MAKE: The 33KV CTs/PTs/JBs/TCs shall be manufactured at our Manufacturing unit Mini Engineering Works, Ghaziabad and PO
shall be in its favour and 110KV CTs/PTs are OFFERED of CGL Make.
16. Painting :- The Rates quoted above are for, All ferrous parts exposed to the atmosphere shall be painted as per IS 5, shade 631, however
since these equipments are meant for Outdoor use, for rust free performance, we suggest Hot dip galvanizing, charges for which are
detailed below:-
For 110 kV: - Rs. 5000/ - Per Unit Extra
For 33 kV: - Rs. 2200/ - Per Unit Extra
Hope you will find our offer in order and will favour us with your valued order.
Thanking you,
Yours faithfully,
FOR Lucky India Power Solutions
SHARAFAT ALI
Managing Director
Mob: +919868667484 / +919759381998
emails: info@luckyindiapowersolution.com / luckyindiapowersolutions@gmail.com / mew.ctpt@gmail.com / ctptmfgrs@outlook.com
website: http://www.luckyindiapowersolution.com
http://www.ctpttransformer.com
http://www.indiamart.com/luckyindiapowersolutions/
linkedin: in.linkedin.com/in/luckyindiapowersolutions
http://ctptvcbpanels.bloombiz.com
skype: luckyindiatrafopanels

You might also like