OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE DEMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI

P/N9363004014
Indoor Unit
CEILING SUSPENSION
TYPE
ABY30TL MA
ABY36TL MA
ABY45TL MA
FLOOR CONSOLE/UNDER
CEILING DUAL TYPE
ABY18TL MA
ABY24TL MA
DUCT TYPE
ARY25TL MA
ARY30TL MA
ARY36TL MA
ARY45TL MA
CASSETTE TYPE
AUY18TL MA
AUY25TL MA
AUY30TL MA
AUY36TL MA
AUY45TL MA
Outdoor Unit
AOY90EP 3L
AOY90TP 3L
AOY90EP MA
AOY90TP MA
OPERATING MANUAL
AIR CONDITIONER
En-2
CONTENTS
SAFETY PRECAUTIONS ....................................... 2
FEATURES AND FUNCTIONS .............................. 3
NAME OF PARTS ................................................... 3
PREPARATION ....................................................... 6
OPERATION ........................................................... 7
TIMER OPERATION (OFF TIMER/ON TIMER) ...... 9
TIMER OPERATION (WEEKLY TIMER) ............... 10
ADJUSTING THE DIRECTION OF AIR
CIRCULATION...................................................... 15
SWING OPERATION............................................ 16
ERRORS AND SELF DIAGNOSIS ....................... 18
CLEANING AND CARE ........................................ 19
TROUBLESHOOTING.......................................... 23
OPERATING TIPS................................................. 24
SPECIFICATIONS ................................................. 25
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.
Do not become over-exposed to cold air by staying in the direct path of the airflow of
the air conditioner for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or the air
filter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
When restarting after a long period of disuse in the winter, do:
Turn the power switch on at least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to infants.
Do not use inflammable gases near the air conditioner.
CAUTION!
SAFETY PRECAUTIONS
Before using the appliance, read these PRECAUTIONS thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain save operating conditions.
DANGER, WARNING and CAUTION have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
En-3
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
HEAT & COOL MODEL (REVERSE CYCLE)
Merely press the START/STOP button, and the unit will be-
gin automatic operation in either the Heating, Cooling or
Monitor modes as appropriate, in accordance with the ther-
mostat setting and the actual temperature of the room.
WEEKLY TIMER FEATURES
Set different operating times for each day of the week.
Set one or two operating spans (one or two ON times
and one or two OFF times) per day.
Set time to a resolution of 5 minutes.
OFF time can be carried over to the subsequent day.
Use the DAY OFF setting to cancel operation for any
day of the coming week (one-time cancellation).
NAME OF PARTS
SWING SWING TIMER OPERATION
MANUAL
AUTO
3 4 5 6
2
1
8
7
9
CEILING SUSPENSION TYPE
Fig. 3 Indoor Unit
0 Operating Control Panel (Fig. 4)
A MANUAL AUTO button
This button has no function on this model of equipment.
B OPERATION Indicator Lamp (red)
C TIMER Indicator Lamp (green)
D SWING Indicator Lamp (orange)
(VERTICAL SWING)
E SWING Indicator Lamp (orange)
(HORIZONTAL SWING)
If the TIMER indicator lamp flashes when the timer is
operating, it indicates that a fault has occurred with
the timer setting (See Page 25 Auto Restart).
F Intake Grille
G Air Filter
H UP/DOWN Air Direction Flaps
I RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flaps)
J Drain Hose
FLOOR CONSOLE/
UNDER CEILING DUAL TYPE
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2)
2 MANUAL AUTO button
This button has no function on this model of equip-
ment.
3 OPERATION Indicator Lamp (red)
4 TIMER Indicator Lamp (green)
5 SWING Indicator Lamp (orange)
(HORIZONTAL SWING)
6 SWING Indicator Lamp (orange)
(VERTICAL SWING)
If the TIMER indicator lamp flashes when the timer is
operating, it indicates that a fault has occurred with
the timer setting (See Page 25 Auto Restart).
7 Intake Grille
8 UP/DOWN Air Direction Flap
9 RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flap)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
En-4
V X W
DUCT TYPE
CASSETTE TYPE
Fig. 5 Indoor Unit
K Outlet Port
L Intake Port
M Drain Hose
Fig. 5
Square Flange
Fig. 6
Compact
NAME OF PARTS
K
L
M
K
M
L
Round Flange
Fig. 8
Fig. 8 Indoor Unit
V Air Filter
W Air Intake Grille
X Air Flow Direction Flaps
Fig. 6 Indoor Unit
N Air Filter
O Air Flow Direction Flaps
P Indicator Lamps (Fig. 7)
Q SWING Indicator Lamp (orange)
R TIMER Indicator Lamp (green)
S OPERATION Indicator Lamp (red)
When the OPERATION indicator and TIMER indicator
flash alternately, it means that the power has been
interrupted due to a power failure, etc. (See Page 25
Auto Restart.)
T MANUAL AUTO Button
This button has no function on this model of equip-
ment.
U Air Intake Grille
SWING TIMER OPERATION MANUAL
AUTO
N O
P
Q
U
RS T
Fig. 7
En-5
Fig. 11
Fig. 9
Fig. 9 Outdoor Unit
Y Intake Port
Z Outlet Port
This breaker is installed during
the electrical installation.
Electrical Breaker
Fig. 10
For explanatory purposes, the figure showing the re-
mote controller display shows all possible displays.
The actual display shows only that area that is being
adjusted or used.
Fig. 12 Display
Fig. 11 Remote Controller
[ START/STOP Button
\ Operation Lamp
] HORIZONTAL SWING Button
_ DAY OFF Button
a HORIZONTAL SWING Lamp
b HORIZONTAL AIR FLOW DIRECTION SET Button
c SET Button
d VERTICAL SWING Button
e VERTICAL SWING Lamp
f VERTICAL AIR FLOW DIRECTION SET Button
g CLOCK ADJUST Button
h TIMER MODE Button
i SET TIME Button
j SET TEMP./DAY Button
k FAN CONTROL Button
l MASTER CONTROL Button
m Remote Controller Display (Fig. 12)
n Timer Mode Display
o Clock Display (CLOCK/TIMER)
p Set Temperature Display (TEMP.)
q Fan Speed Display
r Operation Mode Display
s DEFROST Display
t TEST Display
C
NON STOP CLOCK TEMP.
TIMER
MODE
SET
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
HIGH
AUTO
DAY OFF
C
NON STOP CLOCK
TIMER
NEXT DAY
DAY
TEMP.
OFFON
TIMER
WEEKLY
AUTO
OFF
ON
OFF
ON
DAY OFF
2 1
HIGH
MED
LOW
AUTO
HEAT
FAN
COOL
DEFROST TEST
f dc [
b
] e
_
a
\
i
h l
g
j k
s t
n
m
o p q r
*
Y
Z
Z
Y
Instructions relating to heating(*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
En-6
PREPARATION
Set the Current Time and Day
1
Press the CLOCK ADJUST button for more than three
seconds.
2
Press the SET TEMP./DAY button and set the day.
: Use to advance the day forward.
: Use to turn the day back.
The day is indicated by a code number from 1 to 7, as shown in the table
below. Set to the number that corresponds to the current day.
DAY CODE 1 2 3 4 5 6 7
DAY OF THE WEEK MON TUE WED THU FRI SAT SUN
3
Press the SET TIME button and set the time.
: Use to advance the time forward.
: Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move
10 minutes at a time.)
4
Press the CLOCK ADJUST button again.
This registers the new day and time values. The day display goes off, and
the time display stops flashing.
CLOCK
2 1
Example: Set the time to 9:31.
CLOCK
DAY
AUTO
TIMER
MODE
SET
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
DAY OFF
3
2
1
En-7
Instructions relating to heating(*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Instructions relating to the indoor units indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
To Select Mode Operation
1
Press the START/STOP button.
The unit will start and the remote controllers operation lamp (green) and
**the indoor units OPERATION indicator lamp (red) will light up.
2
Press the MASTER CONTROL button to select the de-
sired mode.
AUTO *HEAT
COOL FAN
To Set the Thermostat
Press the SET TEMP./DAY button to the desired temperature.
: Press to raise the thermostat setting.
: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. 18 to 30 C
* Heating ............................... 16 to 30 C
Cooling ............................... 18 to 30 C
The thermostat cannot be used to set room temperature during the FAN mode
(the temperature will not appear on the remote controllers display).
The thermostat setting should be considered a standard value, and may
differ somewhat from the actual room temperature.
To Set the Fan Speed
Press the FAN CONTROL button to select the fan speed.
AUTO HIGH MED LOW
When set to AUTO:
* Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the tem-
perature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat set-
ting, the fan speed becomes slower.
Fan : The fan alternately turns on and off; when on, the fan runs at the
low fan speed.
The fan will operate at a very low setting during Monitor opera-
tion.
To Stop Operation
Press the START/STOP button.
**The OPERATION indicator lamp (red) will go out.
The remote controllers operation lamp (green) will go out.
The display contents disappear and only the current time is displayed.
d
c c
d
OPERATION
c c c c
Example: When set to HIGH.
Example: When set to AUTO.
Example: When set to 26 C.
C
NON STOP CLOCK TEMP AUTO
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
DEFROST TEST
SET DAY OFF
1
2
C
NON STOP CLOCK TEMP AUTO
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
DEFROST TEST
SET DAY OFF
C
NON STOP CLOCK TEMP AUTO
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
DEFROST TEST
SET DAY OFF
En-8
About Mode Operation
AUTO:
COOLING MODEL
When the room temperature is 2 C higher than the set temperature, the mode
will switch between Cooling and Drying.
During the Drying mode operation, the FAN setting should be switched to LOW
for a gently cooling effect during which the fan may temporarily stop rotating.
If the mode automatically selected by the unit is not satisfactory, see page 7 for
instructions on changing the mode setting (COOL, FAN).
AUTO (* AUTO CHANGEOVER):
HEAT & COOL MODEL (Reverse cycle)
When AUTO CHANGEOVER is selected, the air conditioner selects the appropriate operation mode (Cooling or Heating)
according to your rooms present temperature.
When AUTO CHANGEOVER is first selected, the fan will operate at very low speed for about one minute while the unit
determines the current conditions of the room and accordingly selects the proper operation mode.
When the air conditioner has adjusted your rooms temperature to near the thermostat setting, it will begin monitor opera-
tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the
air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set
in the thermostat. (The monitor operation range is 2 C relative to the thermostat setting.)
If the mode automatically selected by the unit is not satisfactory, see page 7 for instructions on changing the mode setting
(HEAT, COOL, FAN).
Do not select AUTO CHANGEOVER if the difference in the environmental temperatures of the master and slave units is over
2 C. (Otherwise, the indoor fan may not be controlled correctly.)
* Heating:
Use to warm your room.
When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set-
ting. This period of time is provided to allow the indoor unit to warm up before
begin full operation.
When the room temperature is very low, frost may form on the outside unit, and
its performance may be reduced. In order to remove such frost, the unit will
automatically enter the defrost cycle from time to time. During defrosting (see
page 24), the heating mode will be temporarily interrupted. DEFROST will be
shown on the remote controller display **and indoor units OPERATION indica-
tor lamp (red) will flash.
Cooling:
Use to cool your room.
Fan:
Use to circulate the air throughout your room.
Instructions relating to heating(*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Instructions relating to the indoor units indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
* During Heating mode:
Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.
During Cooling mode:
Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling mode will not
operate if the thermostat is set higher than
the actual room temperature (in Cooling
mode, the fan alone will operate).
OPERATION
Setting temperature
Thermostat control
Dry Operation
Cooling Operation
2 C
En-9
TIMER OPERATION (OFF TIMER/ON TIMER)
Instructions relating to the indoor units indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
Before using the timer function, be sure that the remote controller is set to the correct current time and Day.
Press the START/STOP button; after the unit starts operation perform the following procedure:
c c c
OFF Timer / ON Timer
1
Press the TIMER MODE button and display either OFF
Timer or ON Timer.
The timer will start operating. (If you set the ON timer, the air conditioner
will stop operating.)
Each time the button is pressed the timer function changes in the follow-
ing order:
NON STOP (RESET) OFF ON WEEKLY
**The indoor units TIMER indicator lamp (green) will light up.
2
Press the SET TIME button and set the timer time.
: Use to advance the time forward.
: Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move
10 minutes at a time.)
Example: Setting the OFF TIMER to
23:35.
c
To Confirm or Change Settings
Before Starting Operation
To confirm settings
Press the TIMER MODE button once.
(The timer setting information will be
displayed for 15 seconds after the
TIMER MODE button is pressed.)
To change settings
Confirm the settings as noted above,
then press the SET TIME button and
TIMER MODE button as necessary to
change the desired timer setting.
(The timer settings will be displayed
for 15 seconds after the button is
pressed.)
After confirming or changing the set-
tings, press the START/STOP button
to start operation.
To Change the Timer Setting
During Operation
Operate as noted in step 2.
To Change the Timer Mode
During Operation
Press the TIMER MODE button and set
the unit to the desired mode.
To Cancel the Timer Mode
During Timer Operation
Press the TIMER MODE button and set
the display to NON STOP (the unit will
switch to non-stop operation).
To Stop Operation During
Use of Timer Mode
Press the START/STOP button.
C
CLOCK
TIMER
TEMP
OFF
TIMER
AUTO
OFF
TIMER SET TIME TEMP /DAY FAN
2 1
HIGH
AUTO
COOL
DEFROST TEST
C
CLOCK
TIMER
TEMP
OFF
TIMER
AUTO
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
COOL
DEFROST TEST
SET DAY OFF
1 2
En-10
TIMER OPERATION (WEEKLY TIMER)
Use the weekly timer to set operating times for each day of the week.
Weekly Timer Features
Set different operating times for each day of the week.
Set one or two operating spans (one or two ON times and one or two OFF times) per day.
Set time to a resolution of 5 minutes.
OFF time can be carried over to the subsequent day.
Use the DAY OFF setting to cancel operation for any day of the coming week (one-time cancellation).
Setting Up the Weekly Timer Operation
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
1
Press the TIMER MODE button so that WEEKLY ap-
pears on the display.
The display now shows the current day (by DAY CODE), the first ON and
OFF times for the day (the WEEKLY 1 times), the fan speed, and the
operating mode.
The top time value gives the ON time, and the bottom value gives the
OFF time.
If either time is not set, the corresponding time display is blank .
2
Press the SET TEMP./DAY button to select the day that
you want to set up.
: Use to advance the day forward.
: Use to turn the day back.
DAY CODE 1 2 3 4 5 6 7
DAY OF THE WEEK MON TUE WED THU FRI SAT SUN
3
Hold the SET button down for 3 seconds.
The WEEKLY 1 ON time starts flashing, and the fan speed and operat-
ing mode displays go off.
4
Press the SET TIME button to set the days first ON
time.
: Use to advance the time forward.
: Use to turn the time back.
(Press once to move the time 5 minute; hold down and the time will move
10 minutes at a time.)
5
Press the SET button.
This registers the first ON time setting for the selected day.
The ON time display stops flashing, and the WEEKLY 1 OFF time starts
flashing.
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
SET
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
1 2
3
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
SET DAY OFF
4
5
En-11
CLOCK AUTO
TIMER SET TIME TEMP./DAY FAN
2 1
AUTO
DEFROST TEST
NOTES:
(1) If no time values are flashing, the clock display will automatically reappear after 15 seconds if no buttons are pressed.
(2) A flashing time value indicates that the system is in time-setting mode. To return to the clock display you must hold
down the SET button for 3 seconds.
(3) You do not need to set values for both WEEKLY 1 and WEEKLY 2. If you wish, you can set values only for WEEKLY 1
or only for WEEKLY 2.
(4) The allowable range for the days time settings is shown below.
(5) If you set the OFF time to occur on the day following the ON time, the NEXT DAY caption appears on the display.
6
Press the SET TIME button to set the days first OFF
time.
The earliest OFF time you can set is 5 minutes after the ON time. The
latest OFF time is 23:55 on the subsequent day.
7
Press the SET button.
This registers the first OFF time for the day, completing the WEEKLY 1
settings for that day.
The display switches to WEEKLY 2, and the days second ON time be-
gins flashing.
8
Repeat the operations described in Steps 4 to 7 to set
the second ON and OFF times for the day (the WEEKLY
2 times).
When you press the SET button after setting the WEEKLY 2 OFF time,
the system registers the WEEKLY 2 settings for the day and returns you
to the WEEKLY 1 ON time setup process. (The first ON setting reap-
pears and begins flashing.)
You can review your settings by pressing the SET button. Each press
moves you to the next setting, as follows.
WEEKLY 1 WEEKLY 1 WEEKLY 2 WEEKLY 2
ON OFF ON OFF
9
Press the SET TEMP./DAY button to select another day
for setup. The repeat steps 4 to 8 above to set the ON
and OFF times for that day.
10
When you have finished setting all of the times, hold
down the SET button for 3 seconds.
The WEEKLY display flashes for 3 seconds while the new WEEKLY TIMER
settings are registered, and then the clock display reappears.
c c c c
TIMER
NEXT DAY
DAY
WEEKLY
AUTO
ON
OFF
2 1
AUTO
DEFROST TEST
If the timer is not set, press the SET but-
ton with the time display blank ,
and perform next operation.
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
SET DAY OFF
6
7
Next days WEEKLY
settings
Cannot set 5 min. Available range Cannot set 5 min.
ON OFF ON OFF
Previous days WEEKLY
settings
0:00 0:00
En-12
Starting Weekly Timer Operation
1
Press the TIMER MODE button so that WEEKLY ap-
pears on the display.
2
Press the START/STOP button to start operation.
(This step is not necessary if the air conditioner is already running.)
Weekly timer operation starts, and the operation lamp comes on.
(If the current time is between the first or second ON and OFF time set-
tings for the current day, the air conditioner will start. Otherwise the air
conditioner will remain off.)
The day display is replaced by the temperature display.
The upper time display now shows the current time, and the lower time
display shows the next scheduled ON or OFF time.
To Stop Weekly Timer Operation
To stop weekly timer while leaving the air conditioner run-
ning:
Press the TIMER MODE button to select NONSTOP, OFF
TIMER, or ON TIMER.
To stop weekly timer operation and the air conditioner also:
Press the START/STOP button.
Reviewing the Time Settings
Press the START/STOP button to stop the air conditioner, and
then proceed as follows.
1 Press the TIMER MODE button so that WEEKLY appears
on the display.
2 Press the SET TEMP./DAY button to select the day that you
want check.
3 Press the SET TIME button ( or ) to switch between the
WEEKLY 1 or WEEKLY 2 time displays.
Cancelling Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
1
Carry out steps 1 to 3 of the Setting Up the Weekly
Timer Operation procedure to select the day you want
to edit.
2
Press the SET button to select the ON time that you
want to cancel.
Be sure to select an ON time (the upper time display).
3
Hold down the side of the SET TIME button until the
time display becomes blank .
4
Press the SET button.
The first OFF time setting (WEEKLY 1 OFF time) is deleted and replaced
by a flashing blank pattern .
5
Press the SET button again.
This completes deletion of the WEEKLY 1 ON/OFF settings.
The second ON time setting (WEEKLY 2 ON time) appears and flashes.
If you wish to delete other time settings, repeat steps 2 through 5.
6
Once the setting has been canceled, hold down the
SET button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
Example: Clearing the WEEKLY 1
ON/OFF times for day 4
(Thursday).
TIMER DAY
WEEKLY
AUTO
ON
OFF
2 1
AUTO
DEFROST TEST
TIMER DAY
WEEKLY
AUTO
ON
OFF
2 1
AUTO
DEFROST TEST
TIMER OPERATION (WEEKLY TIMER)
C
CLOCK
TIMER
TEMP
WEEKLY
AUTO
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
COOL
DEFROST TEST
SET DAY OFF
1
2
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
SET DAY OFF
2
3
En-13
To Change Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
1
Carry out steps 1 to 3 of the Setting Up the Weekly
Timer Operation procedure to select the day you want
to edit.
2
Press the SET button to select the time that you want
to change.
The selected setting flashes on the display. Each press moves you to the
next setting for the selected day, as follows.
WEEKLY 1 WEEKLY 1 WEEKLY 2 WEEKLY 2
ON OFF ON OFF
3
Press the SET TIME button to change the time setting.
4
Press the SET button.
The new setting overwrites the previous setting.
5
Once the setting has been canceled, hold down the SET
button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
c c c c
Example: Changing the WEEKLY 2
ON setting for day 5 (Friday)
from 14:00 to 15:30.
NOTES:
In the following cases, cancel the set time prior to making the required amendments.
(1) If you want to change the ON time to a time that is later than the currently set OFF time.
(2) If the change would cause a temporary overlap between the first and second ON/OFF time spans.
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
SET DAY OFF
2
TIMER DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
SET DAY OFF
4
3
Temporary overlap
ON OFF
ON OFF
WEEKLY 1
WEEKLY 1
Change
Change
ON OFF
WEEKLY 1
ON OFF
WEEKLY 2
ON
OFF
WEEKLY 1 WEEKLY 2
Time
Time
Time
Time
ON OFF
En-14
About the DAY OFF
Use the DAY OFF setting to switch off timed operation for a selected day in the coming week.
This is a temporary, one-time setting. The DAY OFF setting is automatically cleared as soon as the specified day passes.
Example: To switch off timed opera-
tion for day 2 (Tuesday).
NOTES:
(1) The DAY OFF setting is only available for days for which weekly time settings already exist.
(2) You can make this setting for any of the next seven days (counting from the current day).
(3) The DAY OFF setting is effective over the range illustrated below. The Weekly setting for which an ON time has been
set is eligible for the day in which the DAY OFF has been set.
(4) The display on the clocks lower line will usually be for the DAY OFF set day during Weekly operations.
C
CLOCK
TIMER
TEMP
WEEKLY
AUTO
DAY OFF
TIMER SET TIME TEMP /DAY FAN
2 1
HIGH
AUTO
COOL
DEFROST TEST
Using the DAY OFF Setting
Press the START/STOP button to stop the air conditioner, and then proceed as fol-
lows.
1
Carry out steps 1 to 2 of the Setting Up the Weekly
Timer Operation procedure to select the day that you
want to set as the DAY OFF.
2
Press the DAY OFF button.
The DAY OFF setting is registered, and the DAY OFF caption appears on
the display.
To cancel the DAY OFF setting:
You can cancel the setting by pressing the DAY OFF button again.
Precautions during setup
Setup is not possible in the following cases, so amend the time.
If you set an ON time while leaving the OFF time setting blank:
Nothing will happen when you press the SET button.
To proceed, press the SET TIME button and enter an appropriate setting.
When an attempt is made to set only the OFF time.
Nothing will happen when you press the SET TIME button.
Press the SET button and amend the entry for the ON time.
ON and OFF times cannot be set to the same value.
The OFF time cannot be set earlier than the ON time.
The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings.
The WEEKLY 1 and WEEKLY 2 time spans cannot overlap.
TIMER OPERATION (WEEKLY TIMER)
CLOCK
TIMER DAY
WEEKLY
AUTO
ON
OFF DAY OFF
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
COOL
DEFROST TEST
SET DAY OFF
2
Next day
ON OFF
0:00 0:00
Effective range of DAY OFF setting
WEEKLY setting for preceding
day
WEEKLY setting
Preceding day DAY OFF day
ON OFF
En-15
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Begin air conditioner operation before performing this procedure.
Vertical Air Direction Adjustment
This instructions are applicable to CEILING SUSPENSION TYPE, FLOOR CON-
SOLE/UNDER CEILING DUAL TYPE and CASSETTE TYPE.
Press the VERTICAL AIR FLOW DIRECTION SET button .
Each time the button is pressed, the air direction range will change as follows:
1 2 3 4
The remote controllers display does not change.
Fig. 13
CEILING SUSPENSION TYPE FLOOR CONSOLE/UNDER CEILING
DUAL TYPE
CASETTE TYPE
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance
with the type of operation selected.
During Cooling mode : Horizontal flow 1
* During Heating mode : Downward flow 4
During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this
period.
DANGER!
Never place fingers or foreign objects inside
the outlet port could cause personal injury.
Always use the remote controllers AIR
FLOW DIRECTION button to adjust the
UP/DOWN air direction flap or RIGHT/
LEFT air direction louvers. Attempting
to move them manually could result
in improper operation; in this case,
stop operation and restart. The flaps
should begin to operate properly
again.
During use of the Cooling mode, do not
set the UP/DOWN air direction flap in
the 4 position for long periods of time,
since water vapor may condense near
the outlet port and drops of water may
drip from the air conditioner.
When used in a room with infants, chil-
dren, elderly or sick persons, the air
direction and room temperature
should be considered carefully when
making settings.
Example: When set to vertical air
direction.
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
SET DAY OFF
1
2
3
4
1
2
3
4
1
2
3
4
En-16
C
NON STOP CLOCK TEMP AUTO
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
HIGH
AUTO
COOL
DEFROST TEST
SET DAY OFF
SWING OPERATION
1 2 3 4 5
Horizontal Air Direction Adjustment
This instructions are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
Press the HORIZONTAL AIR FLOW DIRECTION SET button.
Each time the button is pressed, the air direction range will change as follows:
1 2 3 4 5
The remote controllers display does not change.
Fig. 14
CEILING SUSPENSION TYPE
FLOOR CONSOLE/UNDER CEILING DUAL TYPE
Example: When set to horizontal air
direction.
ADJUSTING THE DIRECTION OF AIR CIRCULATION
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
SET DAY OFF
Example: When set to vertical swing.
Instructions relating to the indoor units indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
Begin air conditioner operation before performing this procedure.
To select Vertical airflow SWING Operation
This instructions are applicable to CEILING SUSPENSION TYPE, FLOOR CON-
SOLE/UNDER CEILING DUAL TYPE and CASSETTE TYPE.
Press the VERTICAL SWING button.
The remote controllers VERTICAL SWING lamp (orange) **and indoor units
SWING indicator lamp (VERTICAL SWING) (orange) will light up.
In this mode, the UP/DOWN air direction flaps will swing automatically to direct
the air flow both up and down.
To Stop Vertical airflow SWING Operation
Press the VERTICAL SWING button once again.
The remote controllers VERTICAL SWING lamp **and indoor units SWING in-
dicator lamp (VERTICAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
En-17
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
SET DAY OFF
About Vertical Airflow Swing Operation
The range of swing is relative to the currently set airflow
direction.
Air direction range (See page 15, Fig.13)
If the swing range is not as desired, use the remote con-
trollers VERTICAL AIR FLOW DIRECTION SET button to
change the range of swing.
The SWING operation may stop temporarily when the air
conditioners fan is not operating, or when operating at
very low speeds.
During use of the Cooling mode, do not set the air UP/
DOWN direction flap, in the 4 position for long periods
of time, since water vapor may condense near the outlet
port and drops of water may drip from the air conditioner.
To select Horizontal Airflow SWING Operation
This instructions are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
Press the HORIZONTAL SWING button.
The remote controllers HORIZONTAL SWING lamp (orange) **and indoor units
SWING indicator lamp (HORIZONTAL SWING) (orange) will light up.
In this mode, the RIGHT/LEFT air direction louvers will swing automatically to
direct the airflow both right and left.
Air flow direction set
1
2
3
4
Range of swing
1 to 3
2 to 4
2 to 4
1 to 4 (All range)
Example: When set to horizontal
swing.
To Stop Horizontal airflow SWING Operation
Press the HORIZONTAL SWING button once again.
The remote controllers HORIZONTAL SWING lamp **and indoor units SWING
indicator lamp (HORIZONTAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
About Horizontal Airflow Swing Operation
If the swing range is not as desired, use the remote con-
trollers HORIZONTAL AIR FLOW DIRECTION SET button
to change the range of swing.
The SWING operation may stop temporarily when the air
conditioners fan is not operating, or when operating at
very low speeds.
Air flow direction set
1
2
3
4
5
Range of swing
1 to 5 (All range)
1 to 3
2 to 4
3 to 5
1 to 5 (All range)
Air direction range (See page 16, Fig.14)
The range of swing is relative to the currently set airflow
direction.
Instructions relating to the indoor units indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
SWING OPERATION
En-18
If there is a problem with the air conditioner, it will stop run-
ning and EE: EE will be displayed instead of the clock.
(1) If the operation lamp is on then press the START/
STOP button to turn it off.
(2) Press the SET TIME () and the SET TEMP./DAY ()
buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display area.
(3) Press the SET TIME () and the SET TEMP./DAY () but-
tons again for more than three seconds to end the self
diagnosis check.
ERRORS AND SELF DIAGNOSIS
AUTO
TIMER
MODE
SET
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
2 1
AUTO
DEFROST TEST
DAY OFF
Error Code
Error Code
s t
s t
Error contents
Communication error
(indoor unit remote controller)
Communication error
(indoor unit outdoor unit)
Room temperature sensor open
Room temperature sensor shorted
Indoor heat exchanger temperature
sensor open
Indoor heat exchanger temperature
sensor shorted
Outdoor heat exchanger temperature
sensor open
Outdoor heat exchanger temperature
sensor shorted
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor shorted
Discharge pipe temperature sensor open
Discharge pipe temperature sensor
shorted
Outdoor low pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
En-19
Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply.
Turn off the electrical breaker.
CLEANING AND CARE
CAUTION!
3. Re-attach the air filters to the intake grille.
The air filters fit onto the inside of the intake grille.
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.
If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.
During periods of normal use, the air filters should be
cleaned every four weeks.
Cleaning the Air Filter
1. Pull the air filters upward to remove them.
Remove the air filters by raising its handle while pulling
it out towards you.
2. Clean the air filters.
Remove the dust from the air filters by vacuuming or
washing them. After washing, allow the air filters to dry
thoroughly in an area protected from sunlight.
Air filter
CEILING SUSPENSION TYPE
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
When cleaning the units body, do not use water hotter than 40 C, harsh abrasive cleansers, or volatile agents like
benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
En-20
Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord.
Be sure the intake grille is installed securely.
When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-
sonal injury may result.
CAUTION!
Cleaning the Air Filter
1. Pull out both sides and the center of the
intake grille.
2. Pull the air filters upward to remove them.
Push the air filter handles away from the intake grille in
direction 1, then pull out the air filters.
3. Clean the air filters.
Remove the dust from the air filters by vacuuming or
washing them. After washing, allow the air filters to dry
thoroughly in an area protected from sunlight.
4. Re-attach the air filters to the intake grille.
1The air filters fit onto the inside of the intake grille.
(figure 1)
2The bottom edges of the air filters should fit into the
filter brackets. (figure 1)
3The air filters should be pushed down so that their
top edges fit under the projections at the top of the
intake grille. (figure 2)
5. Push in both sides and the center of the
intake grille.
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.
If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.
During periods of normal use, the air filters should be
cleaned every two weeks.
About 30 mm
Side Panel
Intake Grille
Notch
Arm
Hook
Handle
Intake Grille
Base
Arm
1
Air Filter
Bracket
(figure 1)
Filter bracket
Air Filter
(figure 2)
FLOOR CONSOLE/UNDER CEILING DUAL TYPE
CLEANING AND CARE
En-21
CAUTION!
Cleaning the Air Filter
1. Push the intake grilles hooks inward to-
wards the center of the unit to open the
intake grille.
2. Pull out the filter from the intake grille.
3. Clean the air filters.
Remove the dust from the air filters by vacuuming or
washing them. After washing, allow the air filters to dry
thoroughly in an area protected from sunlight.
4. Re-attach the air filters to the intake grille.
1Replace the air filter into its holder.
2Make sure that the air filter makes contact with the
filter stopper when it is replaced into its holder.
5. Close the intake grille and push the intake
grilles hooks outward.
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.
If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.
During periods of normal use, the air filters should be
cleaned every two weeks.
Grille Hook
Air Filter
Grille Hook Filter Holder Intake Grille
Filter Stopper
Air Filter
Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
Turn off the electrical breaker.
A fan operates at high speed inside the unit, and personal injury could result.
CASSETTE TYPE (COMPACT)
En-22
Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
Turn off the electrical breaker.
A fan operates at high speed inside the unit, and personal injury could result.
CLEANING AND CARE
CAUTION!
Cleaning the Air Filter
1. Push the intake grille pushbuttons (two
places).
2. Open the intake grille.
3. Hold down the hook at A and pull the fil-
ter out.
A
A
B
OPEN
PUSH
Filter
Intake grille
Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
Turn off the electrical breaker.
A fan operates at high speed inside the unit, and personal injury could result.
CAUTION!
Installing the Air Filter
Be sure the filter is always installed in the inlet air grille of the indoor unit.
Filters can be purchased through your local dealer.
Cleaning the Air Filter
If dirt is allowed to collect in the air filter, the airflow will be reduced, leading to reduced performance, and increased
operation noise. Be sure to clean the filters regularly.
How to Cleaning
Use a vacuum cleaner to remove dust and dirt from the air filter, or wash in a synthetic detergent. After washing, dry in a
shaded place, then reinstall.
CASSETTE TYPE
DUCT TYPE
When reinstalling the filter, be sure that the hooks at A
and B engage correctly into place.
4. Clean the air filters.
Remove the dust from the air filters by vacuuming or
washing them. After washing, allow the air filters to dry
thoroughly in an area protected from sunlight.
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.
If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.
During periods of normal use, the air filters should be
cleaned every two months.
B
En-23
TROUBLESHOOTING
Instructions relating to heating(*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Instructions relating to the OPERATION indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the units power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
WARNING!
Symptom
Doesnt operate immedi-
ately:
Noise is heard:
Smells:
Mist or steam are
emitted:
Airflow is weak or stops:
Water is produced from
the outdoor unit:
Problem
If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.
During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioners piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the panel due
to temperature changes.
* During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.
Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.
During Cooling operation, a thin mist may be seen emitted from
the indoor unit. This results from the sudden Cooling of room air
by the air emitted from the air conditioner, resulting in condensa-
tion and misting.
* During Heating operation, the outdoor units fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.
* When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
* During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.
* During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, DEFROST will
be shown on the remote controller display **and the OPERA-
TION indicator lamp will flash.
The fan may operate at very low speed when the unit is monitor-
ing the rooms temperature.
In the monitor AUTO operation, the fan will operate at very low
speed.
* During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.
See Page

24

24

24
8
8
24
NORMAL
FUNCTION
En-24
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Instructions relating to the TIMER indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR CON-
SOLE/UNDER CEILING DUAL TYPE.
Symptom
Doesnt operate at all:
Poor Cooling (or *Heating)
performance:
See Page

9 to 14

CHECK ONCE
MORE
Items to check
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main power switch set to the OFF position.
Is the timer operating?
Is the air filter dirty?
Are the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
If the problem persists after performing these checks, or if you notice burning smells, ** or the TIMER indicator lamp flashes,
stop operation immediately, turn off the electrical breaker, and consult with authorized service personnel.
OPERATING TIPS
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Instructions relating to the OPERATION indicator lamp (**) are applicable to CEILING SUSPENSION TYPE and FLOOR
CONSOLE/UNDER CEILING DUAL TYPE.
Operation and Performance
*Heating Performance
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.
Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.
*Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low out-
door temperature and high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 4 to 15 minutes).
During Automatic Defrosting operation, DEFROST will be
displayed on the remote controller, ** and the OPERATION
indicator lamp (red) will flash.
Low Ambient Cooling
When the outdoor temperature drops, the outdoor units fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.
TROUBLESHOOTING
En-25
Cooling Mode
About 0 to 52 C
About 0 to 52 C
About 18 C to 30 C
About 80 % or less
If the unit is used for long pe-
riods under high-humidity
conditions, condensation
may form on the surface of
the indoor unit, and drip onto
the floor or other objects un-
derneath.
*Heating Mode

About -10 to 21 C
About 16 C to 30 C

Outdoor temperature
Indoor temperature
Indoor humidity
COOLING MODEL
HEAT & COOL MODEL
(Reverse Cycle)
Temperature and Humidity Range
Permissible range of temprature and humidity are as follows:
If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling mode, if the unit is used under conditions of lower tem-
peratures than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in
ordinary dwellings.
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle)
SPECIFICATIONS
Models intended only for cooling have no heating capacity.
CEILING SUSPENSION TYPE
MODEL
POWER
COOLING CAPACITY [kW]
HEATING CAPACITY [kW]
DIMENSIONS & WEIGHT
HEIGHT [mm]
WIDTH [mm]
DEPTH [mm]
WEIGHT [kg]
ABY30TL MA ABY36TL MA ABY45TL MA
220-240 V~50 Hz
8.6-8.8 10.3-10.5 12.4-12.7
8.8-9.1 10.5-10.7 13.4-13.7
240
1,660
700
48
Should the power supply to the air conditioner be inter-
rupted by a power failure, the air conditioner will restart
automatically in the previously selected mode once the
power is restored.
AUTO Restart
In Event of Power Interruption
Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
turn off the circuit breaker, reconnect it, and then use the
remote controller to resume operation.
OPERATING TIPS
En-26
FLOOR CONSOLE/UNDER CEILING DUAL TYPE
MODEL
POWER
COOLING CAPACITY [kW]
HEATING CAPACITY [kW]
DIMENSIONS & WEIGHT
HEIGHT [mm]
WIDTH [mm]
DEPTH [mm]
WEIGHT [kg]
ABY18TL MA ABY24TL MA
220-240 V~50 Hz
5.2-5.3 6.5-6.6
5.5-5.6 7.6-7.7
199
990
655
28 30
DUCT TYPE
MODEL
POWER
COOLING CAPACITY [kW]
HEATING CAPACITY [kW]
DIMENSIONS & WEIGHT
HEIGHT [mm]
WIDTH [mm]
DEPTH [mm]
WEIGHT [kg]
ARY25TL MA ARY30TL MA ARY36TL MA ARY45TL MA
220-240 V~50 Hz
6.95-7.05 8.60-8.80 10.3-10.5 12.4-12.7
7.60-7.85 8.80-9.10 10.5-10.7 13.4-13.7
270
1,210
700
43 45
DUCT TYPE (High pressure)
MODEL
POWER
COOLING CAPACITY [kW]
HEATING CAPACITY [kW]
DIMENSIONS & WEIGHT
HEIGHT [mm]
WIDTH [mm]
DEPTH [mm]
WEIGHT [kg]
ARY36TL MA ARY45TL MA
220-240 V~50 Hz
10.3-10.5 12.4-12.7
10.5-10.7 13.4-13.7
400
1,250
800
75
CASSETTE TYPE
MODEL
POWER
COOLING CAPACITY [kW]
HEATING CAPACITY [kW]
DIMENSIONS & WEIGHT
HEIGHT [mm]
WIDTH [mm]
DEPTH [mm]
WEIGHT [kg]
AUY18TL MA AUY25TL MA AUY30TL MA AUY36TL MA AUY45TL MA
220-240 V~50 Hz
4.85-5.00 6.95-7.05 8.60-8.80 10.3-10.5 12.4-12.7
5.30-5.45 7.60-7.85 8.80-9.10 10.5-10.7 13.4-13.7
235 (35) 296 (35)
580 (650) 830 (940)
580+70 (650) 830 (940)
18 38 38 40 40
SPECIFICATIONS
( ) indicates the dimensions of the grille.