You are on page 1of 5

Unilab Laboratory

PROGRAMMABLE AUTOMATIC
POWER SUPPLY UNIT
DL 1067
DL 1067
ver a20130125
2
GENERAL NOTES

The DL 1067 power supply unit is suitable for regulating the excitation voltage of electric machines
and brakes. It is essentially composed of a motor-driven variator, a control board and a single-phase
bridge.

It can be either internally controlled in manual mode or externally controlled in automatic mode
through the data acquisition system and the relevant software.




TECHNICAL FEAUTURES

Automatic power supply unit having the following features:

Continuously adjustable output voltage: 0 to 210 V
Fixed output current: max. 2A
Magneto-thermal protection
Analog signal INPUT terminals and connectors: 0 to 10 V




OPERATING INSTRUCTIONS

Check the presence and efficiency of the fuse. Check that the main voltage corresponds to the
voltage shown on the plate (220V + E), then connect the power chord to PR1 socket.
Operate the mains switch J1. The pilot lamp of the switch on the front panel must turn on.




MANUAL OPERATION

Open the switch J1, counter-clockwise turn the voltage potentiometer P1 and set the function switch
J2 to manual position MAN.
Connect a 250V range dc voltmeter to B4 and B5 terminals respecting the polarities.
Close the switch J1 and, by clockwise turning the potentiometer P1, read the output voltage on the
voltmeter.



AUTOMATIC OPERATION

Remove the supply of the equipment according to previous point.
Set the switch J2 to AUTO.
Connect the terminals B1 and B2 to the data acquisition system as required by the (software)
program and close the switch J1.
The 0 to 210V, 2A output is protected by the magneto-thermal switch J3.
DL 1067
ver a20130125
3
LAYOUT OF THE CONTROL DEVICE



J1 Pilot lamp
P1 Potentiometer for variable regulation
J2 Control system selection switch
J3 Magneto-thermal protection of variator
B1, B2 Terminals for system connection
B3 Ground terminal
B4, B5 Output terminals




PR1 Main socket with protection fuse (rear of panel)




DL 1067
ver a20130125
4
MAINTENANCE

The unit doesnt require any special maintenance operation.
It can be checked without any difficulty.

In case of faulty operation, DISCONNECT THE MAINS CONNECTION.
Then open the unit and access to the inside.

It is enough to check that the components and the connections are efficient according to the electric
diagram.

The motor is controlled through an electronic board on which a fuse-holder with fuse is assembled.

Check the fuse and the connections. If the equipment doesnt operate it is suggested not to change
the calibrations of the electronic board, otherwise the guarantee would be lost.



1996 - 2013 DE LORENZO SPA - Printed in Italy - All right reserved
DE LORENZO SPA
V.le Romagna, 20 - 20089 Rozzano (MI) Italy
Tel. ++39 02 8254551 - Fax ++39 02 8255181
E-mail: info@delorenzo.it
Web sites: www.delorenzoglobal.com - www.technical-education.it -
www.delorenzoenergy.com

You might also like