You are on page 1of 11

No.

of stores 17
Total height 51
Length Story H 3 Height 10 15 20
55 Lower Upper R1 R2 R3
Width 1 3 1.5 4.5 3 3 X X
40 2 6 4.5 7.5 3 3 X X
CF L 3 9 7.5 10.5 3 2.5 0.5 X
1.2 4 12 10.5 13.5 3 X 3 0
5 15 13.5 16.5 3 X 1.5 1.5
CF B 6 18 16.5 19.5 3 X X 3
1 7 21 19.5 22.5 3 X X 0.5
8 24 22.5 25.5 3 X X X
9 27 25.5 28.5 3 X X X
10 30 28.5 31.5 3 X X X
11 33 31.5 34.5 3 X X X
12 36 34.5 37.5 3 X X X
13 39 37.5 40.5 3 X X X
14 42 40.5 43.5 3 X X X
15 45 43.5 46.5 3 X X X
16 48 46.5 49.5 3 X X X
17 51 49.5 52.5 3 X X X

R1 R2 R3 R4 R5
524.63 524.63 524.63 805.05 925.75
30 50 100 Length width 5
R4 R5 R6
X X X
X X X
X X X
X X X
X X X
X X X
2.5 X X
3 X X
3 0 X
1.5 1.5 X
X 3 X
X 3 X
X 3 X
X 3 X
X 3 X
X 3 X
X 0.5 2.5
Wind force Analyses by gust factor method as per draft code

Building dimensions

Total Height (m) 96


Total Length (m) 24
Total Width (m) 12
Story height (m) 3

Check for dynamic effect


h/smallest side plan dimension 8
it is >5 so use gust factor method IS:875-pt.3,Sec8.1

Location of building Mumbai at sea face


Distance from sea (m) 200

Basic wind speed Vb (m/s) 47 96 sea front

Wind speed multiplication factors

12
1
k1 Risk coefficient as per basic wind speed 24

k3 Topography Factor 1 IS:875-pt.3,Sec5.3.3.1

k4 Importance factor for cyclonic region 1 IS:875-pt.3,Sec5.3.3.4

Kd Wind directionality factor 0.9 IS:875-pt.3,Sec6.1.1

Area Averaging Factor Ka 1 IS:875-pt.3,Sec6.1.2 Table-4


For glazing / clading for 12 m face 0.885
For glazing / clading for 18 m face 0.837

Design wind speed m/s


Vz=Vb*k1*k2*k3*k4 47 k2

k2 Vz(m/s)
Height of building (m)
For sea face For other face For sea face For other face
Up to 9 0.83 0.75 39.01 35.25
12 0.854 0.75 40.138 35.25
18 0.92 0.75 43.24 35.25
24 0.964 0.77 45.308 36.19
30 1 0.8 47 37.6
36 1.232 0.83 57.904 39.01
42 1.242 0.86 58.374 40.42
48 1.248 0.89 58.656 41.83
54 1.253 0.913 58.891 42.911
60 1.258 0.932 59.126 43.804
66 1.263 0.951 59.361 44.697
72 1.268 0.97 59.596 45.59
78 1.272 0.986 59.784 46.342
84 1.277 0.998 60.019 46.906
90 1.282 1.01 60.254 47.47
96 1.287 1.022 60.489 48.034

Fetch length (m) 200


h3 35 IS:875-pt.3, Table-3
Up to 35 m heights,k2 factor shall as per
TC3 and above 35 m it will be as per TC1
pz=0.6*Vz*Vz IS:875-pt.3,Sec5.4
pd=pz*Kd*Ka IS:875-pt.3,Sec6.1

pz(kN/m2) pd(kN/m2) pd for cladding


Height of building (m)
For sea face For other face Sea face Opp.face Wide faces All faces
Up to 9 0.913 0.746 0.727 0.594 0.56 0.822
12 0.967 0.746 0.770 0.594 0.56 0.870
18 1.122 0.746 0.894 0.594 0.56 1.010
24 1.232 0.786 0.981 0.626 0.59 1.109
30 1.325 0.848 1.056 0.676 0.64 1.193
36 2.012 0.913 1.602 0.727 0.69 1.811
42 2.045 0.980 1.628 0.781 0.74 1.840
48 2.064 1.050 1.644 0.836 0.79 1.858
54 2.081 1.105 1.657 0.880 0.83 1.873
60 2.098 1.151 1.671 0.917 0.87 1.888
66 2.114 1.199 1.684 0.955 0.90 1.903
72 2.131 1.247 1.697 0.993 0.94 1.918
78 2.144 1.289 1.708 1.026 0.97 1.930
84 2.161 1.320 1.722 1.051 0.99 1.945
90 2.178 1.352 1.735 1.077 1.02 1.960
96 2.195 1.384 1.749 1.103 1.04 1.976
Wind force calculations

Longe afterbody orientation


Force coefficent
a (m) Face of building perpendicular wind direction 24
b (m) Face of building perellel wind direction 12
a/b 2
h/b 8
Cf (IS:875-pt.3,fig.6) 1.25

Effective Area (m2) 36

F=Cf*Ae*pd*G IS:875-pt.3,Sec6.3

G=gust factor

Gust factor calculation


Lh-Integral turbulence length scale (m) 176.022347358679
f0 0.40093768693724

b 0.02 IS:875-pt.3,Table-40
(1) FOR BASE FLOOR S=0
Bs 0.367018305539274
Hs 1
gR 3.81443544131029
Vh 48
Ih 0.235 IS:875-pt.3,Sec9.1 Table-31
gv 3.5 IS:875-pt.3,Sec9.1
S 0.059
N 2.680
E 0.047
G 0.832

(2) FOR FLOOR LEVEL AT MID HEIGHT (S=48 m)


Lh-Integral turbulence length scale (m) 176.022347358679
f0 0.40093768693724

b 0.02 IS:875-pt.3,Table-40
S (m) 48
Bs 0.504233716555427
Hs 1.25
gR 3.81443544131029
Vh 48
Ih 0.23 IS:875-pt.3,Sec9.1 Table-31
gv 3.5 IS:875-pt.3,Sec9.1
S 0.060
N 2.654
E 0.047
G 0.905

(2) FOR FLOOR LEVEL AT TOP HEIGHT (S=96 m)


Lh-Integral turbulence length scale (m) 176.022347358679
f0 0.40093768693724

b 0.02 IS:875-pt.3,Table-40
S (m) 96
Bs 0.647087818584927
Hs 2
gR 3.81443544131029
Vh 48
Ih 0.4 IS:875-pt.3,Sec9.1 Table-31
gv 3.5 IS:875-pt.3,Sec9.1
S 0.039
N 0.176
E 0.211
G 0.903

ssimiliearly find gust factor for smaler side


for diff.height of build ing
Height (m) gust factor
0 0.932
48 0.990
96 1.09

For cross wind Response


Vn 2.73706794282489
Cfs 0.001 IS:875-pt.3,fig-12
G 1.39205709988421
static Dynamic
F (kN) F (kN)
Height of building (m)
For sea face For sea face
Up to 9 32.727 27.229
12 34.647 28.826
18 40.209 33.574
24 44.147 36.907
30 47.506 40.855
36 72.105 62.732
42 73.281 65.952
48 73.990 66.961
54 74.584 67.424
60 75.181 67.888
66 75.780 68.353
72 76.381 68.819
78 76.863 69.331
84 77.469 69.799
90 78.077 70.425
96 78.687 71.054

Short afterbody orientation


Force coefficent
a (m) Face of building perpendicular wind direction 12
b (m) Face of building perellel wind direction 24
a/b 0.50
h/b 4.00
Cf (IS:875-pt.3,fig.6) 1.4

Effective Area (m2) 72

F=Cf*Ae*pd IS:875-pt.3,Sec6.3
static Dynamic
F (kN) F (kN)
Height of building (m)
For sea face For sea face
Up to 9 59.857 55.787
12 59.857 55.847
18 59.857 56.266
24 63.092 59.937
30 68.104 65.380
36 73.308 71.108
42 78.703 77.129
48 84.289 83.447
54 88.702 88.259
60 92.433 91.878
66 96.240 96.240
72 100.124 99.623
78 103.454 103.247
84 105.987 105.881
90 108.552 108.552
96 111.146 121.149

For cladding:

Depending on the spacing of supporting


structure, but effect of enhanced force at
the corners and edges should be
considered for fasteners by taking local
coefficents from IS:875-pt,Table 5.
For sea face static
Height of building (m) F (kN)
Up to 9 59.85711837 forces Floors wise
12 59.85711837 f1
18 59.85711837 f2
24 63.092063078352 f3
30 68.1040991232 f4
36 73.307677946832 f5
42 78.702799549248 f6
48 84.289463930448 f7
54 88.702290315667 f8
60 92.432585932485 f9
66 96.239711486127 f10
72 100.12366697659 f11
78 103.45395742372 f12
84 105.9874299111 f13
90 108.55154924309 f14
96 111.14631541968 f15
1353.70496544654 f16
f17
f18
f19
f20
f21
f22
f23
f24
f25
f26
f27
f28
f29
f30
f31
f32

0.045033317873582

Comparision of bas
6000
5059.047770784
5000
r (kN)

4000
Comparision of bas
6000
5059.047770784
5000

Base shear (kN)


4000
3000 2656

2000
1000
0
Type of code
Forces (KN) forces Floors wise Forces (KN)
115.550916768 f1 59.85711837 Height of building (m
115.550916768 f2 59.85711837
115.550916768 f3 59.85711837
122.319999648 f4 59.85711837
125.704541088 f5 59.85711837
133.60032 f6 59.85711837
137.234248704 f7 59.85711837
144.502106112 f8 63.092063078
144.502106112 f9 63.092063078
144.502106112 f10 68.104099123
161.6563872 f11 68.104099123
161.6563872 f12 73.307677947
161.6563872 f13 73.307677947
161.6563872 f14 78.702799549
161.6563872 f15 78.702799549
161.6563872 f16 84.28946393
168.732750816 f17 84.28946393
182.885478048 f18 88.702290316
182.885478048 f19 88.702290316
182.885478048 f20 92.432585932
182.885478048 f21 92.432585932
182.885478048 f22 96.239711486
182.885478048 f23 96.239711486
182.885478048 f24 100.12366698
182.885478048 f25 100.12366698
182.885478048 f26 103.45395742
182.885478048 f27 103.45395742
182.885478048 f28 105.98742991
182.885478048 f29 105.98742991
182.885478048 f30 108.55154924
182.885478048 f31 108.55154924
60.961826016 f32 111.14631542
2656.1207338
5059.047770784
-0.954967

Comparision of base shear (kN)

5059.047770784
Comparision of base shear (kN)

5059.047770784

2656.12073384339 Runnig code


Draft code

Type of code
For sea face static
Height of building (m) F (kN)
Up to 9 59.85711837
12 59.85711837
18 59.85711837
24 63.092063078
30 68.104099123
36 73.307677947
42 78.702799549
48 84.28946393
54 88.702290316
60 92.432585932
66 96.239711486
72 100.12366698
78 103.45395742
84 105.98742991
90 108.55154924
96 111.14631542