You are on page 1of 59

Report No.

: TS08100034-EME
Page 1 of 59

EMC
TEST REPORT

Report No.: TS08100034-EME


Model No.: TTD-41T, TTD-61R
Issued Date: Oct. 23, 2008

Applicant: TRANWO TECHNOLOGY CORP.


6F., No. 49, Guangming 6th Rd., Jubei City, Hsinchu,
Taiwan

Test Method/ EN 301 489-17 V1.2.1


Standard: EN 301 489-1 V1.6.1
EN 61000-3-2: 2006
EN 61000-3-3: 1995+A1: 2001+A2: 2005

Test By: Intertek Testing Services Taiwan Ltd.


No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
Shiang-Shan District, Hsinchu City, Taiwan

This test report consists of 59 pages in total. It may be duplicated completely


for legal use with the allowance of the applicant. It shall not be reproduced
except in full, without the written approval of Intertek Laboratory. The test
result(s) in this report only applies to the tested sample(s).

Report Engineer

Julie Wang
Reviewed By
Project Engineer

Rex Liao Rico Deng


Report No.: TS08100034-EME
Page 2 of 59

Table of Contents
1. General information...................................................................................................... 4
1.1 Identification of the EUT........................................................................................ 4
1.2 Additional information about the EUT................................................................... 4
2. Test specifications......................................................................................................... 5
2.1 Test standards.......................................................................................................... 5
2.2 Additions, deviations and exclusions from standards............................................. 5
2.3 Operation mode ...................................................................................................... 5
2.4 Performance criteria ............................................................................................... 6
2.5 Performance verification ........................................................................................ 6
3. Test summary................................................................................................................ 7
4. EN 55022 Conducted emission test.............................................................................. 8
4.1 Operating environment ........................................................................................... 8
4.2 Test setup & procedure ........................................................................................... 8
4.3 Test equipment........................................................................................................ 9
4.4 Emission limit......................................................................................................... 9
4.5 Uncertainty of Conducted Emission....................................................................... 9
4.6 Conducted emission test data ............................................................................... 10
5. EN 55022 Radiated emission test............................................................................... 14
5.1 Operating environment ......................................................................................... 14
5.2 Test setup & procedure ......................................................................................... 14
5.3 Test equipment...................................................................................................... 16
5.4 Emission limit....................................................................................................... 16
5.5 Uncertainty of Radiated Emission........................................................................ 16
5.6 Radiated emission test data .................................................................................. 17
6. EN 61000-3-2 Harmonics test .................................................................................... 21
6.1 Operating environment ......................................................................................... 21
6.2 Test setup & procedure ......................................................................................... 21
6.3 Test equipment...................................................................................................... 21
6.4 Uncertainty of Radiated Emission........................................................................ 21
6.5 Test result.............................................................................................................. 22
7. EN 61000-3-3 Voltage fluctuations-flicker Test......................................................... 24
7.1 Operating environment ......................................................................................... 24
7.2 Test setup & procedure ......................................................................................... 24
7.3 Test equipment...................................................................................................... 24
7.4 Uncertainty of Radiated Emission........................................................................ 24
7.5 Test result.............................................................................................................. 25
8. EN 61000-4-2 Electrostatic discharge immunity test................................................. 27
8.1 Operating environment ......................................................................................... 27
8.2 Purpose ................................................................................................................. 27
8.3 Test set-up............................................................................................................. 27
8.4 Test conditions ...................................................................................................... 27
8.5 Test equipment...................................................................................................... 28
8.6 Test result.............................................................................................................. 28
9. EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
9.1 Operating environment ......................................................................................... 30
Report No.: TS08100034-EME
Page 3 of 59

9.2 Purpose ................................................................................................................. 30


9.3 Test set-up............................................................................................................. 30
9.4 Test conditions ...................................................................................................... 30
9.5 Test equipment...................................................................................................... 31
9.6 Generation of the electromagnetic field ............................................................... 31
9.7 Test results ............................................................................................................ 32
10. EN 61000-4-4 Electrical fast transient/burst immunity test ..................................... 33
10.1 Operating environment ....................................................................................... 33
10.2 Purpose ............................................................................................................... 33
10.3 Test set-up........................................................................................................... 33
10.4 Test condition ..................................................................................................... 33
10.5 Test equipment.................................................................................................... 33
10.6 Test results .......................................................................................................... 34
11. EN 61000-4-5 Surge immunity test.......................................................................... 35
11.1 Operating environment ....................................................................................... 35
11.2 Purpose ............................................................................................................... 35
11.3 Test set-up ........................................................................................................... 35
11.4 Test conditions .................................................................................................... 35
11.5 Test Equipment................................................................................................... 36
11.6 Test results .......................................................................................................... 36
11.6.1 Main power ports............................................................................................. 36
12. EN 61000-4-6 Immunity to conducted disturbances, inducted by
radio-frequency fields................................................................................................. 37
12.1 Operating environment ....................................................................................... 37
12.2 Purpose ............................................................................................................... 37
12.3 Test set-up........................................................................................................... 37
12.4 Test conditions .................................................................................................... 37
12.5 Test equipment.................................................................................................... 38
12.6 Generation and calibration of the disturbance signal ......................................... 38
12.7 Test results .......................................................................................................... 39
13. EN 61000-4-11 Voltage dips, short interruptions and voltage variations
immunity test .............................................................................................................. 40
13.1 Operating environment ....................................................................................... 40
13.2 Purpose ............................................................................................................... 40
13.3 Test set-up........................................................................................................... 40
13.4 Test condition ..................................................................................................... 40
13.5 Test equipment.................................................................................................... 40
13.6 Generation of the disturbance signal .................................................................. 41
13.7 Test result............................................................................................................ 41

Appendix A1: External photo of EUT (TTD-41T) ....................................................... 42


Appendix A2: External photo of EUT (TTD-61R)....................................................... 43
Appendix A3: External photo of Adapter ..................................................................... 44
Appendix A4: Internal photo of EUT (TTD-41T) ........................................................ 45
Appendix A5: Internal photo of EUT (TTD-61R) ........................................................ 52

Appendix B1: Conducted Emission Test Set-up........................................................... 56


Appendix B2: Radiated Emission Test Set-up.............................................................. 58
Report No.: TS08100034-EME
Page 4 of 59

1. General information

1.1 Identification of the EUT

Applicant: TRANWO TECHNOLOGY CORP.


Product: Digital Wireless Video Baby Monitor
Model No.: TTD-41T, TTD-61R
Operating Frequency: 2408 MHz ~ 2470.5 MHz
Channel Number: 52 channels
Type of Modulation: FSK
Rated Power: DC 6V from adapter (LK-D060080),
I/P Voltage: 230-240 Vac, 50 Hz
DC 3.7V from Li-ion battery for TTD-61R
DC 6V from battery (1.5V * 4) for TTD-41T
Power Cord: N/A
Sample Received: Aug. 26, 2008
Test Date(s): Oct. 07, 2008 ~ Oct. 14, 2008
Note 1: This report is for the exclusive use of Intertek's Client and
is provided pursuant to the agreement between Intertek
and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement.
Intertek assumes no liability to any party, other than to
the Client in accordance with the agreement, for any loss,
expense or damage occasioned by the use of this report.
Only the Client is authorized to permit copying or
distribution of this report and then only in its entirety.
Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek. The
observations and test results in this report are relevant
only to the sample tested. This report by itself does not
imply that the material, product, or service is or has ever
been under an Intertek certification program.
Note 2: The test report only allows to be revised within three
years from its original issued date unless further standard
or the requirement was noticed.
Note 3: When determining the test conclusion, the Measurement
Uncertainty of test has been considered.

1.2 Additional information about the EUT

The EUT is a Digital Wireless Video Baby Monitor, and was defined as information
technology equipment.

For more detail features, please refer to user's Manual.


Report No.: TS08100034-EME
Page 5 of 59

2. Test specifications

2.1 Test standards

EN 301 489-17 V1.2.1 Electromagnetic compatibility and Radio spectrum Matters


(ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for Wideband data and HIPERLAN equipment

EN 301 489-1 V1.6.1 Electromagnetic compatibility and Radio spectrum Matters


(ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and
services; Part 1: Common technical requirements

EN 61000-3-2: 2006 Electromagnetic compatibility ― Part 3. Limits


Section 2. Limits for harmonic current emissions (equipment input current ≤ 16 A per
phase)

EN 61000-3-3: 1995+A1: 2001+A2: 2005 Electromagnetic compatibility ― Part 3.


Limits Section 3. Limitation of voltage fluctuations and flicker in low-voltage supply
systems for equipment with rated current ≤ 16 A

2.2 Additions, deviations and exclusions from standards

No additions, deviations or exclusions have been made from standard

2.3 Operation mode

The EUT was supplied with DC 6V from adapter (230 Vac, 50 Hz) and was tested in
normal operating mode.
Report No.: TS08100034-EME
Page 6 of 59

2.4 Performance criteria

Performance table
Criteria During test After test
Shall operate as intended Shall operate as intended
May show degradation of Shall be no degradation of performance(Note 2)
A performance(Note1) Shall be no loss of function
Shall be no loss of function Shall be no loss of stored data or user
programmable functions
Shall be no unintentional transmissions
May show loss of function (one or Functions shall be self-recoverable
more) Shall operate as intended after recovering
B May show degradation of performance Shall be no degradation of performance(Note 2)
(Note 1) Shall be no loss of stored data or user
No unintentional transmissions programmable functions
May be loss of function (one or more) Functions shall be recoverable by the operator
C Shall operate as intended after recovering
Shall be no degradation of performance(Note 2)
Note 1: Degradation of performance during the test is understood as a degradation to a level not
below a minimum performance level specified by the manufacturer for the use of the
apparatus as intended. In some cases the specified minimum performance level may be
replaced by a permissible degradation of performance.
If the minimum performance level or the permissible performance degradation is not
specified by the manufacturer then either of these may be derived from the product
description and documentation (including leaflets and advertising) and what the user may
reasonably expect from the apparatus if used as intended.
Note 2: No degradation of performance after the test is understood as no degradation below a
minimum performance level specified by the manufacturer for the use of the apparatus as
intended. In some cases the specified minimum performance level may be replaced by a
permissible degradation of performance. After the test no change of actual operating data
or user retrievable data is allowed.
If the minimum performance level or the permissible performance degradation is not
specified by the manufacturer then either of these may be derived from the product
description and documentation (including leaflets and advertising) and what the user may
reasonably expect from the apparatus if used as intended.

2.5 Performance verification

The EUT has been monitored based on manufacturer’s specification, the performance
fulfilled the requirements of standard.
Report No.: TS08100034-EME
Page 7 of 59

3. Test summary
(EN 301 489-17)
Emission
Standard Test Type Result Remarks
Pass by -23.77 dB at 30.000 MHz
Conducted Test PASS
EN 55022: 2006 Line Phase
Class B Pass by -1.84 dB at 528.000 MHz
Radiated Test PASS
With antenna polarization Horizontal
EN 61000-3-2: 2006 Harmonic current
PASS Meet the requirements
Class A Emissions
EN 61000-3-3: 1995 Voltage fluctuation
PASS Meet the requirements
+A1: 2001+A2: 2005 & Flicker

Immunity
Standard Test Type Result Performance Criteria Test Judgment
EN 61000-4-2: 1995 Meets the requirements of
ESD test PASS Criterion B
+A1: 1998+ A2: 2001 Performance Criterion B
EN 61000-4-3: 2006 Meets the requirements of
RS test PASS Criterion A
+A1: 2007 Performance Criterion A
Meets the requirements of
EN 61000-4-4: 2004 EFT test PASS Criterion B
Performance Criterion B
Meets the requirements of
EN 61000-4-5: 2006 Surge test PASS Criterion B
Performance Criterion A
Meets the requirements of
EN 61000-4-6: 2007 CS test PASS Criterion A
Performance Criterion A

EN 61000-4-11: 2004 Dip test PASS 1. 30 % reduction- Meets the requirements of


Performance Criterion B Voltage Dips:
2. 60 % reduction- 1. 30 % reduction- Performance
Performance Criterion C Criterion A
3. >95 % reduction- 2. 60 % reduction- Performance
Performance Criterion C Criterion B
3. >95 % reduction-
Performance Criterion B

Remark:
The EUT has been tested/evaluated and pass the above standards without modification.
Report No.: TS08100034-EME
Page 8 of 59

4. EN 55022 Conducted emission test

4.1 Operating environment

Temperature: 24 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 53 % Test Voltage: 230 Vac, 50 Hz

4.2 Test setup & procedure

(1) TTD-41T
wireless

AC Power
AMN 1 TTD-41T

wireless

AMN 2 TTD-61R
EMI
Receiver

AC Power
(2) TTD-61R

wireless

AC Power
AMN 1 TTD-61R

wireless

AMN 2 TTD-41T
EMI
Receiver

AC Power
The EUT along with its peripherals were placed on a 1.0 meter(W)×1.5 meter(L)
and 0.8 meter in height wooden table and the EUT was adjusted to maintain a
0.4meter space from a vertical reference plane. The EUT was connected to power
mains through a Artificial Mains Network (AMN), which provided 50 ohm coupling
impedance for measuring instrument and the chassis ground was bounded to the
horizontal ground plane of shielded room.
The excess power cable between the EUT and the AMN was bundled. All connecting
cables of EUT and peripherals were moved to find the maximum emission
Report No.: TS08100034-EME
Page 9 of 59

4.3 Test equipment

Equipment Brand Model No.


EMI Receiver Rohde & Schwarz ESCS 30
AMN Rohde & Schwarz EHS3-Z5
AMN Schaffner MN2050D
Shield Room N/A N/A
Note: The above equipments are within the valid calibration period.

4.4 Emission limit

Freq. Maximum RF Line Voltage


Limits for conducted
emission of equipment
Limits for conducted
(MHz) intended to be used in
emissions(dBμV)
telecommunication centres
only(dBμV)

Q.P. Ave. Q.P. Ave.

0.15~0.50 79 66 66~56 56~46

0.50~5.00 73 60 56 46

5.00~30.0 73 60 60 50

4.5 Uncertainty of Conducted Emission

Expanded uncertainty (k=2) of conducted emission measurement is ±2.26 dB.


Report No.: TS08100034-EME
Page 10 of 59

4.6 Conducted emission test data

Phase: Line
Model No.: TTD-41T
Test Condition: Normal operation mode

Remark:
1. Corr. Factor (dB)= AMN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100034-EME
Page 11 of 59

Phase: Neutral
Model No.: TTD-41T
Test Condition: Normal operation mode

Remark:
1. Corr. Factor (dB)= AMN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100034-EME
Page 12 of 59

Phase: Line
Model No.: TTD-61R
Test Condition: Normal operation mode

Remark:
1. Corr. Factor (dB)= AMN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100034-EME
Page 13 of 59

Phase: Neutral
Model No.: TTD-61R
Test Condition: Normal operation mode

Remark:
1. Corr. Factor (dB)= AMN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100034-EME
Page 14 of 59

5. EN 55022 Radiated emission test

5.1 Operating environment

Temperature: 25 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 53 % Test Voltage: 230 Vac, 50 Hz

5.2 Test setup & procedure

The Diagram below shows the test setup, which is utilized to make these measurements.

(1) TTD-41T

Antenna
Tower

1.0~4.0 meter
wireless Receiver
10 meter
Antenna

TTD-41T

0.8 meter

Ground Plane

wireless □

RF Test
TTD-61R Receiver
Report No.: TS08100034-EME
Page 15 of 59

(2) TTD-61R
Antenna
Tower

1.0~4.0 meter
wireless Receiver
10 meter
Antenna

TTD-61R

0.8 meter

Ground Plane

wireless □

RF Test
TTD-41T Receiver

Radiated testing was performed at a 10 meters open area test site. The devices under test
were placed on a turntable top 0.8 meter above ground. The table was 360 degrees to
determine the position of the highest radiation. EUT is set 10 meters from the EMI
receiving antenna, which is mounted on the top of a variable height mast. The antenna
height is varied between one meter and four meters above ground to find the
maximum value of the field strength. Both horizontal polarization and vertical
polarization of the antenna was set to conduct the measurement.
The bandwidth was set on the EMI meter 120 kHz.
The levels are quasi peak value readings. The frequency spectrum from 30 MHz to 1000
MHz was investigated.
Report No.: TS08100034-EME
Page 16 of 59

5.3 Test equipment

Equipment Brand Model No.


EMI Receiver Rohde & Schwarz ESCS 30
Bilog Antenna Schaffner CBL6112B
Note: The above equipments are within the valid calibration period.

5.4 Emission limit

Limits for radiated


Limits for radiated
emissions from ancillary
emissions from
equipment intended for use
Frequency (MHz) Distance (m) ancillary equipment,
in telecommunication
measured on a stand
centres only, and measured
alone basis
on a stand alone basis

30~230 10 40 30
230~1000 10 47 37

Note:
1. The tighter limit shall apply at the edge between two frequency bands.
2. Distance refers to the distance in meters between the measuring instrument
antenna and the closet point of EUT.

5.5 Uncertainty of Radiated Emission

Expanded uncertainty (k=2) of radiated emission measurement is ±4.68 dB.


Report No.: TS08100034-EME
Page 17 of 59

5.6 Radiated emission test data

Polarity: Vertical
Model No.: TTD-41T
Test Condition: Normal operation mode

Remark:
1. Level (dBμV/m)= Factor (dB/m)+ Read Level (dBμV)
2. Factor = Antenna Factor (dB/m) + Cable Loss (dB)
3. Over Limit (Margin) (dB) = Level (dBμV/m) – Limit Line(dBμV/m)
Report No.: TS08100034-EME
Page 18 of 59

Polarity: Horizontal
Model No.: TTD-41T
Test Condition: Normal operation mode

Remark:
1. Level (dBμV/m)= Factor (dB/m)+ Read Level (dBμV)
2. Factor = Antenna Factor (dB/m) + Cable Loss (dB)
3. Over Limit (Margin) (dB) = Level (dBμV/m) – Limit Line(dBμV/m)
Report No.: TS08100034-EME
Page 19 of 59

Polarity: Vertical
Model No.: TTD-61R
Test Condition: Normal operation mode

Remark:
1. Level (dBμV/m)= Factor (dB/m)+ Read Level (dBμV)
2. Factor = Antenna Factor (dB/m) + Cable Loss (dB)
3. Over Limit (Margin) (dB) = Level (dBμV/m) – Limit Line(dBμV/m)
Report No.: TS08100034-EME
Page 20 of 59

Polarity: Horizontal
Model No.: TTD-61R
Test Condition: Normal operation mode

Remark:
1. Level (dBμV/m)= Factor (dB/m)+ Read Level (dBμV)
2. Factor = Antenna Factor (dB/m) + Cable Loss (dB)
3. Over Limit (Margin) (dB) = Level (dBμV/m) – Limit Line(dBμV/m)
Report No.: TS08100034-EME
Page 21 of 59

6. EN 61000-3-2 Harmonics test

6.1 Operating environment

Temperature: 25 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 55 % Test Voltage: 230 Vac, 50 Hz

6.2 Test setup & procedure

AC power Measuring
EUT
Equipment

PC controller

Harmonics of the fundamental current were measured up to 2 kHz using a digital power
analyzer. The test voltage was supplied from an AC source, which meets the
requirements according to the standard.

The steady-state harmonic current measurements were carried out using averaging.

The transitory harmonics were measured during an observation period of 5 minutes.


The disturbance duration time (limit 15 s) is defined as the total time under which the
transitory harmonics exceeds the limit level for steady-state harmonics during an
observation period of 5 minutes.

6.3 Test equipment

Equipment Brand Model No.

EMC Emission Tester EMC Partner HARMONICS-1000

Note: The above equipments are within the valid calibration period.

6.4 Uncertainty of Radiated Emission

Expanded uncertainty (k=2) of radiated emission measurement is ±0.2 dB.


Report No.: TS08100034-EME
Page 22 of 59

6.5 Test result

EUT: TTD-41T
Power Freq.: 50Hz
Power Voltage: 230Vac

CLASSIFICATION: CLASS A
SUMMARY RESULT: PASS

Harmonic Current Results

Current Current
Hn AMPs Limit
Result Hn AMPs Limit
Result
1 0.023 NA Pass 21 0.000 0.107 Pass
2 0.000 1.080 Pass 22 0.000 0.084 Pass
3 0.008 2.300 Pass 23 0.000 0.098 Pass
4 0.000 0.430 Pass 24 0.000 0.077 Pass
5 0.006 1.140 Pass 25 0.000 0.090 Pass
6 0.000 0.300 Pass 26 0.000 0.071 Pass
7 0.001 0.770 Pass 27 0.000 0.083 Pass
8 0.000 0.230 Pass 28 0.000 0.066 Pass
9 0.001 0.400 Pass 29 0.000 0.078 Pass
10 0.000 0.184 Pass 30 0.000 0.061 Pass
11 0.001 0.330 Pass 31 0.000 0.073 Pass
12 0.000 0.153 Pass 32 0.000 0.058 Pass
13 0.000 0.210 Pass 33 0.000 0.068 Pass
14 0.000 0.131 Pass 34 0.000 0.054 Pass
15 0.000 0.150 Pass 35 0.000 0.064 Pass
16 0.000 0.115 Pass 36 0.000 0.051 Pass
17 0.000 0.132 Pass 37 0.000 0.061 Pass
18 0.000 0.102 Pass 38 0.000 0.048 Pass
19 0.000 0.118 Pass 39 0.000 0.058 Pass
20 0.000 0.092 Pass 40 0.000 0.046 Pass
Report No.: TS08100034-EME
Page 23 of 59

EUT: TTD-61R
Power Freq.: 50Hz
Power Voltage: 230Vac

CLASSIFICATION: CLASS A
SUMMARY RESULT: PASS

Harmonic Current Results

Current Current
Hn AMPs Limit
Result Hn AMPs Limit
Result
1 0.023 NA Pass 21 0.000 0.107 Pass
2 0.000 1.080 Pass 22 0.000 0.084 Pass
3 0.008 2.300 Pass 23 0.000 0.098 Pass
4 0.000 0.430 Pass 24 0.000 0.077 Pass
5 0.006 1.140 Pass 25 0.000 0.090 Pass
6 0.000 0.300 Pass 26 0.000 0.071 Pass
7 0.001 0.770 Pass 27 0.000 0.083 Pass
8 0.000 0.230 Pass 28 0.000 0.066 Pass
9 0.001 0.400 Pass 29 0.000 0.078 Pass
10 0.000 0.184 Pass 30 0.000 0.061 Pass
11 0.001 0.330 Pass 31 0.000 0.073 Pass
12 0.000 0.153 Pass 32 0.000 0.058 Pass
13 0.000 0.210 Pass 33 0.000 0.068 Pass
14 0.000 0.131 Pass 34 0.000 0.054 Pass
15 0.000 0.150 Pass 35 0.000 0.064 Pass
16 0.000 0.115 Pass 36 0.000 0.051 Pass
17 0.000 0.132 Pass 37 0.000 0.061 Pass
18 0.000 0.102 Pass 38 0.000 0.048 Pass
19 0.000 0.118 Pass 39 0.000 0.058 Pass
20 0.000 0.092 Pass 40 0.000 0.046 Pass
Report No.: TS08100034-EME
Page 24 of 59

7. EN 61000-3-3 Voltage fluctuations-flicker Test

7.1 Operating environment

Temperature: 25 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 55 % Test Voltage: 230 Vac, 50 Hz

7.2 Test setup & procedure

Measuring
AC power EUT
Equipment

PC controller

The voltage changes at the supply terminals were measured using the voltage method.

The test voltage was supplied from an AC source which meets the requirements
according to the standard. The voltage source has virtually zero internal impedance
and is connected

(1 phase)
Z = 0.4 + j 0.25 Ω (total impedance)

(3 phases)
Impedance in line conductor: Za = 0.25 + j 0.25 Ω
Impedance in neutral conductor: Zn = 0.15 +j 0.10 Ω

The short-term flicker Pst is measured during a time interval of 10 minutes.


The long-term flicker Plt is evaluated from 12 subsequently measured short-term flicker
values.

7.3 Test equipment

Equipment Brand Model No.

EMC Emission Tester EMC Partner HARMONICS-1000

Note: The above equipments are within the valid calibration period.

7.4 Uncertainty of Radiated Emission

Expanded uncertainty (k=2) of radiated emission measurement is ±0.47 dB.


Report No.: TS08100034-EME
Page 25 of 59

7.5 Test result

EUT: TTD-41T
Power Freq.: 50Hz
Power Voltage: 230Vac

SUMMARY RESULT: PASS

TEST CONDITIONS: STANDARD TEST CONDITIONS

EUT DATA LIMIT RESULT TEST ENABLED


Pst max 0.072 1.00 PASS
Plt max 0.072 0.65 PASS
dc % 0.01 3.30 PASS
dmax % 0.00 4.00 PASS ⌧
d(t) Sec. 0.00 0.50 PASS
Report No.: TS08100034-EME
Page 26 of 59

EUT: TTD-61R
Power Freq.: 50Hz
Power Voltage: 230Vac

SUMMARY RESULT: PASS

TEST CONDITIONS: STANDARD TEST CONDITIONS

EUT DATA LIMIT RESULT TEST ENABLED


Pst max 0.072 1.00 PASS
Plt max 0.072 0.65 PASS
dc % 0.01 3.30 PASS
dmax % 0.00 4.00 PASS ⌧
d(t) Sec. 0.00 0.50 PASS
Report No.: TS08100034-EME
Page 27 of 59

8. EN 61000-4-2 Electrostatic discharge immunity test

8.1 Operating environment

Temperature: 26 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 53 % Test Voltage: 230 Vac, 50 Hz

8.2 Purpose

The object of the test is to evaluate the ESD immunity performance of EUT.

8.3 Test set-up

A horizontal coupling plane (HCP) was placed on a non-metallic table 0.8 meter above
a reference ground plane (RGP) and connected to it with a cable with two 470 kΩ
resistors. The EUT was placed on an insulation sheet on the HCP and was operated
according to the specified operating mode.

A vertical coupling plane (VCP) was connected to the RGP with a cable with two 470 k
Ω resistors.

8.4 Test conditions

Test level: Air discharge ------- +/- 8 kV


Contact discharge ------- +/- 4 kV
Single discharge at > 1 second interval positive discharge and negative discharge
Report No.: TS08100034-EME
Page 28 of 59

8.5 Test equipment

Equipment Manufacturer Model No.


Electrostatic Discharge
NoiseKen ESS-2002
System
Note: The above equipments are within the valid calibration period.

8.6 Test result

EUT: TTD-41T

Applied Total No. of


Criteria
Point of Discharge Voltage Discharge Result Remark
Level
(kV) (Each Point)
±2 75 P A -
Contact Test Point
±4 75 P B -
±2 20 P A -
Air Test Point ±4 20 P A -
±8 20 P B -
VCP ±2 20 P A -
(4 sides) ±4 20 P A -
HCP ±2 20 P A -
(4 sides) ±4 20 P A -

Description
Contact Discharge: 2 test points Air Discharge
Metallic Screws Plastic Screws
Metallic Case Plastic Case (gap)
Metallic Connect ports Plastic Connect ports
Metallic Junctions Plastic Junctions
Others: LED indicator
Panel Board
Others:Right/Left side buttons,
Turn/OFF volume buttons
Report No.: TS08100034-EME
Page 29 of 59

EUT: TTD-61R

Applied Total No. of


Criteria
Point of Discharge Voltage Discharge Result Remark
Level
(kV) (Each Point)
±2 - - - -
Contact Test Point
±4 - - - -
±2 20 P A -
Air Test Point ±4 20 P A -
±8 20 P B -
VCP ±2 20 P A -
(4 sides) ±4 20 P A -
HCP ±2 20 P A -
(4 sides) ±4 20 P A -

Description
Contact Discharge: 0 test points Air Discharge
Metallic Screws Plastic Screws
Metallic Case Plastic Case (gap)
Metallic Connect ports Plastic Connect ports
Metallic Junctions Plastic Junctions
Others: LED indicator
Panel Board
Others:Right/Left side buttons,
Turn/OFF volume buttons
Report No.: TS08100034-EME
Page 30 of 59

9. EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test

9.1 Operating environment

Temperature: 22 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 51 % Test Voltage: 230 Vac, 50 Hz

9.2 Purpose

This test method subjects the EUT to a power source of disturbance comprising electric
and magnetic field, simulating those coming from intentional RF transmitters.

9.3 Test set-up

The EUT was placed on a non-metallic table 0.8 meter above the reference ground
plane (RGP) and was operated according to its specified operating mode.

Ferrite tiles/absorbers were placed on the RGP between the EUT and the antenna to
reduce the reflections from the RGP. The EUT and its cables were exposed for the
electromagnetic field for 1.5 meter vertically and 1.5 meter horizontally.

The distance between antenna and EUT is 3 meter.

9.4 Test conditions

Test field strength


Test level Modulation
V/m
1 1 1 kHz 80 % AM
2 3 1 kHz 80 % AM
3 10 1 kHz 80 % AM
X Special 1 kHz 80 % AM

The frequency steps : 1 ﹪, Log sweep


Dwell time : 3 sec
Frequency range : 80 MHz~1 GHz, 1.4 GHz~2 GHz
Test ports : Enclosure port
Test voltage : 3 V/m
Report No.: TS08100034-EME
Page 31 of 59

9.5 Test equipment

Equipment Manufacture Model No.


An-echoic chamber
7m×3m×3m
Comtest Instrumentation 9708093

RF signal Generator Marconi 2023B


Dual Band RF Power
Kalmus 757LCB
Amplifier
High Power Microwave
MILMEGA AS0102-30
Amplifier Series
Bi-log Antenna EMCO 3141

RF Power Meter Boonton 4230

Power Sensor Boonton 51011-EMC

Power Sensor Boonton 51011-EMC

Field Probe Holaday HI-4422


Note: The above equipments are within the valid calibration period.

9.6 Generation of the electromagnetic field

The electromagnetic field is generated from a computer controlled signal generator.


The output power is amplified and then radiated from broadband log periodic antennas.
For each sweep a pre-recorded empty chamber calibration file is used to establish the
required field strength. When using these files the field strength inside an area of
1.5/1.0 meter x 1.5meter is in accordance with the standard.
Report No.: TS08100034-EME
Page 32 of 59

9.7 Test results

Exposed Side: ⌧ Front ⌧ Left ⌧ Rear ⌧ Right

H: Horizontal V: Vertical

EUT: TTD-41T

Frequency Horizontal/ Criteria


Result Remark
(MHz) Vertical Level
80 MHz to 1 GHz H P A -
1.4 GHz to 2 GHz H P A -
80 MHz to 1 GHz V P A -
1.4 GHz to 2 GHz V P A -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable

EUT: TTD-61R

Frequency Horizontal/ Criteria


Result Remark
(MHz) Vertical Level
80 MHz to 1 GHz H P A -
1.4 GHz to 2 GHz H P A -
80 MHz to 1 GHz V P A -
1.4 GHz to 2 GHz V P A -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable
Report No.: TS08100034-EME
Page 33 of 59

10. EN 61000-4-4 Electrical fast transient/burst immunity test

10.1 Operating environment

Temperature: 22 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 51 % Test Voltage: 230 Vac, 50 Hz

10.2 Purpose

The purpose of this test is to evaluate the EUT performance during the repetitive
transient bursts applied to power port and ports for I/O ports.

10.3 Test set-up

For power port testing, the EUT was placed on a non-metallic table 0.1 meter above a
reference ground plane (RGP) and was put into operation according to the specified
operating mode.

10.4 Test condition

Open-circuit output test voltage (±10 %) and repetition rate of the impulses (±20 %)
On I/O (Input/Output) signal,
On power supply port, PE
Data and control ports
Level Voltage peak Repetition rate Voltage peak Repetition rate
kV kHz kV kHz
1 0.5 5 or 100 0.25 5 or 100
2 1 5 or 100 0.5 5 or 100
3 2 5 or 100 1 5 or 100
4 4 5 or 100 2 5 or 100
(1)
X Special Special Special Special
NOTE 1 Use of 5 kHz repetition rates is traditional; however, 100 kHz is closer to reality. Product
committees should determine which frequencies are relevant for specific products or product types.
NOTE 2 With some products, there may be no clear distinction between power ports and I/O ports, in
which case it is up to product committees to make this determination for test purposes.
(1) “x” is an open level. The level has to be specified in the dedicated equipment
specification

10.5 Test equipment

Equipment Manufacture Model No.

EFT/Burst Tester Keytek CE40


Note: The above equipments are within the valid calibration period.
Report No.: TS08100034-EME
Page 34 of 59

10.6 Test results

EUT: TTD-41T

Power supply line and Signal Line & Criteria


Level Polarity
Protective earth terminal Control Line Level
0.25 kV + - - -
0.25 kV - - - -
0.5 kV + - - -
0.5 kV - - - -
1 kV + P - A
1 kV - P - A
2 kV + - - -
2 kV - - - -
4 kV + - - -
4 kV - - - -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable

EUT: TTD-61R

Power supply line and Signal Line & Criteria


Level Polarity
Protective earth terminal Control Line Level
0.25 kV + - - -
0.25 kV - - - -
0.5 kV + - - -
0.5 kV - - - -
1 kV + P - B
1 kV - P - B
2 kV + - - -
2 kV - - - -
4 kV + - - -
4 kV - - - -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable
Report No.: TS08100034-EME
Page 35 of 59

11. EN 61000-4-5 Surge immunity test

11.1 Operating environment

Temperature: 22 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 51 % Test Voltage: 230 Vac, 50 Hz

11.2 Purpose

The object of this test is to establish a common reference to evaluate the performance of
EUT when subjected to high-energy disturbances on the power and interconnection
lines.

11.3 Test set-up

The EUT was placed on a non-metallic support 0.8 meter above a reference ground
plane and was put into operation according to the specified operating mode.

11.4 Test conditions

Open circuit test voltage


Level Remark
kV +/- 10 %
1 0.5 L1 to L2
2 1.0 L1 to L2
3 2.0 -
4 4.0 -
X Special -

Note: “X” is an open class. This level can be specified in the product specification
Surge wave form: 1.2 x 50 µs, Repetition rate: 1 /min (max)
Report No.: TS08100034-EME
Page 36 of 59

11.5 Test Equipment.

Equipment Manufacture Model No.

Surge Tester Key Tek EMC Pro


Note: The above equipments are within the valid calibration period.

11.6 Test results

11.6.1 Main power ports

Test 5 times for each voltage

EUT: TTD-41T

Phase Criteria
0o 90o 180o 270o
Volt Mode Polarity level
+ P P P P A
0.5 kV L1 to L2
- P P P P A
+ P P P P A
1 kV L1 to L2
- P P P P A
+ - - - - -
L1 to Gnd
1 kV/ - - - - - -
2 kV + - - - - -
L2 to Gnd
- - - - - -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable

EUT: TTD-61R

Phase Criteria
0o 90o 180o 270o
Volt Mode Polarity level
+ P P P P A
0.5 kV L1 to L2
- P P P P A
+ P P P P A
1 kV L1 to L2
- P P P P A
+ - - - - -
L1 to Gnd
1 kV/ - - - - - -
2 kV + - - - - -
L2 to Gnd
- - - - - -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable
Report No.: TS08100034-EME
Page 37 of 59

12. EN 61000-4-6 Immunity to conducted disturbances, inducted by


radio-frequency fields

12.1 Operating environment

Temperature: 22 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 51 % Test Voltage: 230 Vac, 50 Hz

12.2 Purpose

The test method subjects the EUT to a power source of disturbance comprising electric
and magnetic field, simulating those coming from intentional RF transmitters.
The measurement is for evaluating the performance of EUT when subjected to RF
conducted disturbance.

12.3 Test set-up

The EUT was placed on a non-metallic support 0.1 meter above a reference ground
plane (RGP) with the coupling/decoupling network (CDN) placed 0.3 meter from the
EUT on the RGP.

12.4 Test conditions

Voltage
Test level Modulation
(Vrms)
1 1 1 kHz 80 % AM
2 3 1 kHz 80 % AM
3 10 1 kHz 80 % AM
X Special 1 kHz 80 % AM

The frequency steps : 1 ﹪, Log sweep


Dwell time : 3 sec
Frequency range : 150 kHz to 80 MHz
Test ports : AC port
Test voltage : 3 Vrms
Report No.: TS08100034-EME
Page 38 of 59

12.5 Test equipment

Equipment Manufacture Model No.


RF signal Generator Marconi 2023B

RF-Generator SCHAFFNER NSG2070


Dual Band RF Power
Kalmus 757LCB
Amplifier
Coupling Decoupling
Comtest instrument 4412-016
Network
Coupling Decoupling
Comtest instrument 4413-016
Network
Multimeter CHY 36B

RF Injection Clamp Luthi EM101

RF Power Meter Boonton 4230

Power Sensor Boonton 51011-EMC

Power Sensor Boonton 51011-EMC


Note: The above equipments are within the valid calibration period.

12.6 Generation and calibration of the disturbance signal

The disturbance signal is generated from a computer controlled signal generator.


The output signal is amplified and injected to the CDN/injection clamp. The disturbance
signal level was calibrated as specified in the standard. A power meter was connected to
the EUT side of the CDN through a 150 -50 Ω adapter. The auxiliary equipment (AE)
side of the network was terminated with 150 Ω to ground during the calibration. The
generator settings obtained during the calibration procedure were later repeated in the
tests.
Report No.: TS08100034-EME
Page 39 of 59

12.7 Test results

EUT: TTD-41T

Frequency Criteria
Test Port/Line Result Remark
(MHz) Level
0.15 MHz to 80 MHz Power Line P A -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable

EUT: TTD-61R

Frequency Criteria
Test Port/Line Result Remark
(MHz) Level
0.15 MHz to 80 MHz Power Line P A -
Note: 1. “P” means the EUT pass the test.
Note: 2. “-“ means not applicable
Report No.: TS08100034-EME
Page 40 of 59

13. EN 61000-4-11 Voltage dips, short interruptions and voltage variations


immunity test

13.1 Operating environment

Temperature: 22 ℃ Atmospheric Pressure: 1023 hPa


Relative Humidity: 51 % Test Voltage: 230 Vac, 50 Hz

13.2 Purpose

The object of this standard is to establish a common reference for evaluating the
Immunity of electrical and electronic equipment when subjected to voltage dips, Short
interruptions, and voltage variations.

13.3 Test set-up

The EUT was placed on a non-metallic support 0.8 meter above a reference ground
plane and was put into operation according to the specified operating mode.

13.4 Test condition

Reduction Test Duration Recovery


Level % UT Tests
'% of rated (Period) Time
60 % Dip 40 % 0.5 3 10 Sec.
30 % Dip 70 % 5 3 10 Sec.

Test Duration
Tests Recovery Time
Level % UT (Period)
0 % Short Circuit 250 3 10 Sec.
0 % Open Circuit 250 3 10 Sec.

13.5 Test equipment

Equipment Manufacturer Model No.

Dip Tester Keytek EMC Pro


Note: The above equipments are within the valid calibration period.
Report No.: TS08100034-EME
Page 41 of 59

13.6 Generation of the disturbance signal

The disturbance signal is generated using a programmable AC power source with


pre-programmed test sequences for each test.

13.7 Test result

EUT: TTD-41T

I. Dip of mains voltage


Test Reduction Test Duration Recovery Criteria
Level '% of rated Level % UT (Period) Tests Time Level
1 60 % Dip 40 % 0.5 3 10 Sec. A
2 30 % Dip 70 % 5 3 10 Sec. B

II. 0 ﹪of mains voltage


Test Duration Recovery Criteria
Test Item Tests
Level % UT (Period) Time Level
1 0 % Short Circuit 250 3 10 Sec. B
2 0 % Open Circuit 250 3 10 Sec. B

EUT: TTD-61R

I. Dip of mains voltage


Test Reduction Test Duration Recovery Criteria
Level % U Tests
Level '% of rated T (Period) Time Level
1 60 % Dip 40 % 0.5 3 10 Sec. A
2 30 % Dip 70 % 5 3 10 Sec. B

II. 0 ﹪of mains voltage


Test Duration Recovery Criteria
Test Item Tests
Level % UT (Period) Time Level
1 0 % Short Circuit 250 3 10 Sec. B
2 0 % Open Circuit 250 3 10 Sec. B
Report No.: TS08100034-EME
Page 42 of 59

Appendix A1: External photo of EUT (TTD-41T)


Report No.: TS08100034-EME
Page 43 of 59

Appendix A2: External photo of EUT (TTD-61R)


Report No.: TS08100034-EME
Page 44 of 59

Appendix A3: External photo of Adapter


Report No.: TS08100034-EME
Page 45 of 59

Appendix A4: Internal photo of EUT (TTD-41T)


Report No.: TS08100034-EME
Page 46 of 59
Report No.: TS08100034-EME
Page 47 of 59
Report No.: TS08100034-EME
Page 48 of 59
Report No.: TS08100034-EME
Page 49 of 59
Report No.: TS08100034-EME
Page 50 of 59
Report No.: TS08100034-EME
Page 51 of 59
Report No.: TS08100034-EME
Page 52 of 59

Appendix A5: Internal photo of EUT (TTD-61R)


Report No.: TS08100034-EME
Page 53 of 59
Report No.: TS08100034-EME
Page 54 of 59
Report No.: TS08100034-EME
Page 55 of 59
Report No.: TS08100034-EME
Page 56 of 59

Appendix B1: Conducted Emission Test Set-up

TTD-41T

TTD-41T
Report No.: TS08100034-EME
Page 57 of 59

TTD-61R

TTD-61R
Report No.: TS08100034-EME
Page 58 of 59

Appendix B2: Radiated Emission Test Set-up

TTD-41T

TTD-41T
Report No.: TS08100034-EME
Page 59 of 59

TTD-61R

TTD-61R