You are on page 1of 31

Back to Content

DENISON HYDRAULICS
high performance hydraulic vane pumps
single, double, triple
T7 and T67 industrial application

Publ. 1 - AM0705 - A

09 / 2000 / 2000 / FB

Replaces : 1 - AM 079 - B

L14 - 10705 - 1

CONTENTS - T7 AND T67 SERIES INDUSTRIAL APPLICATION

GENERAL

General characteristics.................................................................................................... 3
Minimum and maximum speeds .................................................................................... 4
Pressure ratings ............................................................................................................... 4
Minimum allowable inlet pressure ................................................................................. 5
Main calculation ............................................................................................................. 6
Intermittent pressure rating............................................................................................. 6
Description...................................................................................................................... 7
Application advantages................................................................................................... 7
Hydraulic fluids .............................................................................................................. 8
Shafts .............................................................................................................................. 9
Priming at starting........................................................................................................... 9
General characteristics.................................................................................................... 9
Formulas ....................................................................................................................... 10
Notes ............................................................................................................................. 11

T7B - T7BS

Ordering code and technical data ................................................................................. 12


Dimensions and operating characteristics .................................................................... 13

T7BB - T7BBS

Ordering code and technical data ................................................................................. 14


Dimensions and operating characteristics .................................................................... 15

T67CB

Ordering code and technical data ................................................................................. 16


Dimensions and operating characteristics .................................................................... 17

T67DB

Ordering code and technical data ................................................................................. 18


Dimensions and operating characteristics .................................................................... 19

T67EB

Ordering code and technical data ................................................................................. 20


Dimensions and operating characteristics .................................................................... 21

T67DBB

Ordering code and operating characteristics ................................................................ 22


Technical data ............................................................................................................... 23
Dimensions ................................................................................................................... 26

T67DCB

Ordering code and operating characteristics ................................................................ 24


Technical data ............................................................................................................... 25
Dimensions ................................................................................................................... 26

T67EDB

Dimensions .................................................................................................................. 27
Ordering code and operating characteristics ................................................................ 28
Technical data ............................................................................................................... 29
Porting diagrams for double and triple pumps ............................................................. 30
Porting diagrams for triple pumps................................................................................ 31
Addresses ...................................................................................................................... 32

Back to Content
2

CARACTERISTICS - T7 AND T67 SERIES INDUSTRIAL APPLICATION

CHARACTERISTICS

These T67 series vane pumps have been specially designed for high/low circuit. The
combination of different cartridges in double and triple pumps allows low flow at high
pressure (4350 PSI max.) and high flow at lower pressure. This is a clever way to
optimize your circuit design.
This pump feature will also allow a very fast pressure cycle change with a very precise
flow repeatability.

GREATER FLOW

B:
C:
D:
E:

.35 to 3.05 in3/rev.


.66 to 6.10 in3/rev.
2.90 to 9.64 in3/rev.
8.07 to 13.86 in3/rev.

HIGHER PRESSURE

B:
C:
D:
E:

4650 PSI max. (4350 PSI for multiple pump).


4000 PSI max.
3500 PSI max.
3500 PSI max.

WIDE SPEED RANGE

Industrial pumps : from 600 to 3600 RPM

BETTER EFFICIENCY

Over 94 % under high pressure, which increases productivity and reduces heating and
operation costs.

LOW NOISE LEVELS

Increase operators safety and acceptance.

MOUNTING FLEXIBILITY

Single pumps : 4 positions.


Double pumps : 32 positions.
Triple pumps : 128 positions.

CARTRIDGE DESIGN

Provides for drop-in assemblies. It allows easy conversion and service.


B cartridge
: bi-directional
C, D and E cartridges : Uni-directional.

WIDE RANGE OF ACCEPTABLE


VISCOSITIES

Viscosities from 3900 to 60 SUS permit colder starts and hotter running. The balanced
design compensates for wear and temperature changes. At high viscosity or cold
temperature, the rotor to side plates gap is well lubricated and improves mechanical
efficiency.

FIRE RESISTANT FLUIDS AND


BIODEGRADABLE FLUIDS

Including phosphate esters, organic esters, chlorinated hydrocarbons, water glycols,


rapeseed, may be pumped at higher pressures and with longer service life by these
pumps.

GENERAL APPLICATIONS
INSTRUCTIONS

1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rotation.
2. Check inlet conditions of the pump, if it can accept application requirement.
3. Type of shaft : if would support operating torque.
4. Coupling must be chosen to minimize pump shaft load (weight, misalignment).
5. Filtration : must be adequate for lowest contamination level.
6. Environment of pump : to avoid noise reflection, pollution and shocks.

Back to Content
3

MINIMUM AND MAXIMUM SPEED, PRESSURE RATINGS - T7 AND T67 SERIES INDUSTRIAL APPLICATION
Theoretical
Displacement Minimum
Vi
Speed
Series Size Displ.

T7

T67
C

B02
B03
B04
B05
B06
B07
B08
B10
B12
B15
B02
B03
B04
B05
B06
B07
B08
B10
B12
B15
003
005
006
008
010
012
014
017
020
022
025
028
031
014
017
020
024
028
031
035
038
042
045
050
042
045
050
052
062
066
072

in3/rev.
.35
.60
.78
.97
1.21
1.37
1.52
1.94
2.50
3.05
.35
.60
.78
.97
1.21
1.37
1.52
1.94
2.50
3.05
.66
1.05
1.30
1.61
2.08
2.26
2.81
3.56
3.89
4.29
4.84
5.42
6.10
2.90
3.55
4.00
4.80
5.50
6.00
6.80
7.30
8.30
8.90
9.64
8.07
8.70
9.67
10.00
12.00
13.00
13.86

Maximum Speed
HF-0,HF-1 HF-3, HF-4
HF-2
HF-5

RPM

RPM

RPM

HF-0, HF-2
Int. Cont.
PSI
PSI

600

3600

1800

4650

4200

4350
4060

4000
3500

4350*

4000

4060

3500

4000

3500

3000

2300

3500

3000

3000

2300

3500

3000

3000

600

3600

1800

Maximum Pressure
HF-1, HF-4, HF-5
Int.
Cont.
PSI
PSI

HF-3
Int. Cont.
PSI
PSI

3500

3000

2500

2000

3500

3000

2500

2000

3000

2500

2500

2000

2500

2000

2500

2000

3000

600

2800

1800

2500

600

2500

1800

2300

3000

2500

2200

600

2200

1800

2300

3000

2500

HF-0, HF-2 = Antiwear petroleum base. HF-1 = Non antiwear petroleum base. HF-5 = Synthetic fluids.
HF-3 = Water in oil emulsions. HF-4 = Water glycols.
* Please consult DENISON Hydraulics for applications over 4350 PSI.
For further information or if the performance characteristics outlined above do not meet your own particular requirements, please consult your local
DENISON Hydraulics office.

Back to Content
4

MINIMUM ALLOWABLE INLET PRESSURE (PSI ABSOLUTE) - T7 AND T67 SERIES INDUSTRIAL APPLICATION

Cartridges
Size Displ.
B02
B03
B04
B05
B06
B
B07
B08
B10
B12
B15
003
005
006
008
010
C
012
014
017
020
022
025
028
031
014
017
020
024
028
D
031
035
038
042
045
050
042
045
050
E
052
062
066
072

1200

11.6

1500

11.6

1800

11.6

2100

11.6

Speed RPM
2200
2300

11.6

11.6

2500

11.6

12.2

11.6

2800

11.6

14.3

13.0

11.6

14.5

11.6
11.6

11.6

11.6

12.3
12.3

13.3
13.8

14.9

14.2
15.2
15.7
16.1
14.5

15.2

13.0
12.3
13.0
12.3
11.6

11.6
11.6

11.9
12.3
13.0
13.3
13.8

13.0
13.8
14.2
13.0

13.8
14.2
14.5

12.8

13.8

14.5

12.3

14.2
14.8

13.3
13.8
14.2
14.5
14.8
15.2
15.8

14.5

11.6

11.6

11.6

11.6

13.0

12.3

12.3

12.3
13.8
12.3

13.8
14.5

14.8
15.2
15.7

15.8
15.2

16.0
17.1
17.8
18.7

3000

3600

11.6

11.6

11.9

14.2

12.3
13.0

15.2
15.2

16.4

Displ.
B02
B03
B04
B05
B06
B07
B08
B10
B12
B15
003
005
006
008
010
012
014
017
020
022
025
028
031
014
017
020
025
028
031
035
038
042
045
050
042
045
050
052
062
066
072

Inlet pressure is measured at inlet flange with petroleum base fluids at a viscosity between 60 and 300 SUS. The difference between
inlet pressure at the pump flange and atmospheric pressure must not exceed 2.9 PSI to prevent aeration.
Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids.
by 1,35 for HF-5 fluid.
by 1,10 for ester or rapeseed base.
Use the cartridge with the highest absolute pressure for double and triple pumps.

Back to Content
5

PUMP SELECTION - T7 AND T67 SERIES INDUSTRIAL APPLICATION

MAIN CALCULATION

To resolve
Volumetric displ.
Available flow
Input power

Vi [in3/rev.]
qv [GPM]
P [HP]

Routine :
1. First calculation Vi =

Performances required
Requested flow qv [GPM] 19.8
Speed
n [RPM] 2500
Pressure
p [PSI] 3600

Example :
231 Q
n

2. Choose Vi of pump immediately


greater (see tabulation)
3. Theoretical flow of this pump
Vp x n
qVi =
231

Vi =

231 x 19.8
= 1.83 in3/rev.
2500

T7B B10, Vi = 1.94 in3/rev.

qVI =

1.94 x 2500
= 21.0 GPM
231

4. Find qVs leakage function of


pressure qVs = f(p) on curve at 60 or
115 SUS

T7B (page 12) : qVS = .79 GPM at


3600 PSI, 115 SUS

5. Available flow qVe = qVi - qVs

qVe = 21.0 - .79 = 20.21 GPM

6. Theoretical input power


qvi x p
Pi =
1714

Pi =

21.0 x 3600
= 44.1 HP
1714

7. Find Ps hydrodynamical power


loss on curve

T7B (page12) : Ps at 2500 RPM,


3600 PSI = 1.2 HP

8. Calculation of necessary input


power P = Pi + Ps

P = 44.1 + 1.2 = 45.3 HP

9. Results

Vi = 1.94 in3/rev.
qVe = 20.21 GPM
P = 45.30 HP

T7B B10

These calculation steps must be followed for each application.

INTERMITTENT PRESSURE
RATING

T7 and T67 units may be operated intermittently at pressures higher than the
recommended continuous rating when the time weighted average of pressure is less
than or equal to the continuous duty pressure rating. This intermittent pressure rating
calculation is only valid if other parameters : speed, fluid, viscosity and contamination
level are respected.
For total cycle time longer than 15 minutes, please consult your DENISON Hydraulics
representative.
Example : T7B - B10
Duty cycle
4 min. at 4650 PSI
1 min. at 500 PSI
5 min. at 2300 PSI
(4 x 4650) + (1 x 500) + (5 x 2300)
= 3070 PSI
10
3070 PSI is lower than 4200 PSI allowed as continuous pressure for T7B - B10 with
HF-0 fluid.

Back to Content
6

DESCRIPTION - T7 AND T67 SERIES INDUSTRIAL APPLICATION

Inlet

Shaft end outlet port has


4-positions at 90 intervals
relative to inlet.

Outlet

Inlet

Cap end outlet port has 8-positions


at 45 intervals relative to inlet on
each double and triple pump.

Front & rear sideplates are


each clamped axially by the
separate discharge pressures.
Pilot recess as required by
SAE for full conformity.
Shaft comes in variety
of keyed and splined
options to meet SAE
and ISO 3019-1.

Ball bearing holds


shaft in alignment.

The cartridge is a replaceable


assembly including cam ring, rotor,
vanes, pins and sideplate.

Vane is urged outward at


suction ramp by pin force
and centrifugal force..

90 Section

The cartridges are replaceable assemblies. Each


includes cam ring, rotor, vanes, pins and sideplates.

Holes in cam ring improve wide


cartridge inlet characteristics.

Working vane on major arc


pushes fluid to discharge port.

Suction ramp
where unloaded
vane moves out.

Section B-B
Pin cavity is at a steady
pressure equal to that at
discharge port.

Section A-A

Side feed holes supply discharge


pressure to pin cavities.

Discharge ramp
where unloaded
vane moves in.

Nota : The "E" and "B" size cartridges are with 12 vanes.

APPLICATION ADVANTAGES

Working vane on minor arc seals


discharge pressure from the
suction port.

The high pressure capability up to 4650 PSI, in the small envelope, reduces
installation costs and provides extended life at reduced pressure.

The high volumetric efficiency, typically better than 94%, reduces heat generation,
and allows speeds down to 600 RPM at full pressure.

The high mechanical efficiency, typically better than 94%, reduces energy
consumption.

The wide speed range (600 RPM at 3600 RPM), combined with large size cartridge
displacements will optimize operation for the lowest noise level in the smallest
envelope.

The low speed (600 RPM), low pressure, high viscosity (3900 SUS) allows
applications in cold environment with a minimum energy consumption and without
risk of seizure.

The low ripple pressure ( 29 PSI) reduces piping noise and increases lifetime of
other components in the circuit.

The high resistance to particle contamination, because of the double lip vane,
increases pump life.

The large variety of options (cam displacement, shaft, porting) allows customized
installation.

Noise : Specially designed to optimize the low noise level characteristics.

Cartridge concept : drops maintenance costs by two.

Back to Content
7

HYDRAULIC FLUIDS - T7 AND T67 SERIES INDUSTRIAL APPLICATION

RECOMMENDED FLUIDS

Petroleum based antiwear R & O fluids


These fluids are the recommended fluids for T7 and T67 series pumps. Maximum
catalog ratings and performance data are based on operation with these fluids. These
fluids are covered by DENISON Hydraulics HF-0 and HF-2 specifications.

ACCEPTABLE ALTERNATE
FLUIDS

The use of fluids other than petroleum based antiwear R & O fluids requires that the
maximum ratings of the pumps will be reduced. In some cases, the minimum
replenishment pressures must be increased. Consult specific sections for more details
(page 4).

VISCOSITY

Max. (cold start, low speed & pressure) ____________________________3900 (SUS)


Max. (full speed & pressure) _____________________________________500 (SUS)
Optimum (max. life)____________________________________________140 (SUS)
Min. (full speed & pressure for
HF-1, HF-3, HF-4 & HF-5 fluids)__________________________________90 (SUS)
Min. (full speed & pressure for HF-0 & HF-2 fluids) ___________________60 (SUS)

VISCOSITY INDEX

90 min. Higher values extend the range of operating temperatures.


Maximum fluid temperature () F
HF-0, HF-1, HF-2________________________________________________
HF-3, HF-4 _____________________________________________________
HF-5 __________________________________________________________
Biodegradable fluids (esters & rapeseed base)__________________________

+ 212
+ 122
+ 158
+ 149

Minimum fluid temperature () F


HF-0, HF-1, HF-2, HF-5 ___________________________________________ - 0.4
HF-3, HF-4 ______________________________________________________ + 50
Biodegradable fluids (esters & rapeseed base)___________________________ - 4.4
FLUID CLEANLINESS

The fluid must be clean before and during operation to maintain contamination level of
NAS 1638 class 8 (or ISO 18/14) or better. Filters with 25 micron (or better, 10 100)
nominal ratings may be adequate but do not guarantee the required cleanliness levels.
Suction strainers must be of adequate size to provide minimum inlet pressure specified.
100 mesh (149 micron) is the finest mesh recommended. Use oversize strainers or omit
them altogether on applications which require cold starts or use fire resistant fluids.

OPERATING TEMPERATURES
AND VISCOSITIES

Operating temperatures are a function of the fluid viscosities, fluid type, and pump.
Fluid viscosity should be selected to provide optimum viscosity at normal operating
temperatures. For cold starts, the pumps should be operated at low speed and pressure
until fluid warms up to an acceptable viscosity for full power operation.

WATER CONTAMINATION IN
THE FLUID

Maximum acceptable content of water :


0,10 % for mineral base fluids.
0,05 % for synthetic fluids, crankcase oils and biodegradable fluids.
If amount of water is higher, then it should be drained off the circuit.

Back to Content
8

SHAFTS - T7 AND T67 SERIES INDUSTRIAL APPLICATION

SPLINED SHAFTS
COUPLING SPLINES

The mating female spline should be free to float and find its own center. If both
members are rigidly supported, they must be aligned within .006 TIR or less to reduce
fretting. The angular alignment of two spline axes must be less than .002 per 1"
radius.
The coupling spline must be lubricated with a lithium molydisulfide grease or a
similar lubricant.
The coupling must be hardened to a hardness between 27 and 45 R.C.
The female spline must be made to conform to the Class 1 fit as described in
SAE-J498b (1971). This is described as a Flat Root Side Fit.

KEYED SHAFT

DENISON Hydraulics supplies the T7 and T67 series keyed shaft pumps with high
strength heat-treated keys. Therefore, when installing or replacing these pumps, the
heat-treated keys must be used in order to ensure maximum life in the application. If
the key is replaced, it must be a heat-treated key between 27 and 34 R.C. hardness. The
corners of the keys must be chamfered .030" to .040" at 45 to clear radii in the key
way.

NOTE

Alignment of keyed shafts must be within tolerances given for splined shafts.

SHAFT LOADS

These products are designed primarily for coaxial drives which do not impose axial or
side loading on the shaft. Consult specific sections for more details.

PRIMING AT STARTING

When the pump is set into operation for the first time, it must be primed at the lowest
possible speed and pressure. When a pressure relief valve is used at the outlet, it should
be backed off to minimize return pressure.
When possible, an air bleed off should be provided in the circuit to facilitate purging of
system air.
Never operate the pump at maximum speed and pressure without making sure that the
pump priming is completed and that the fluid is disaerated.

Mounting
standard

Weight without
connector and
bracket - Lbs

Moment of
inertia
lb.in2

ISO
3019-2 100 A2HW
SAE J744c
ISO/3019-1 SAE B
ISO
3019-2 100 A2HW

50.7

1.1

Suction
1"1/2

50.7

1.1

1" 1/2

71.8

4.0

2" 1/2

71.8

4.0

57.3

T67DBB
T67DCB

SAE J744c
ISO/3019-1 SAE B
SAE J744c
ISO/3019-1 SAE B
SAE J744c
ISO/3019-1 SAE C
SAE J744c
ISO/3019-1 SAE C
SAE J744c
ISO/3019-1 SAE C

T67EDB

ISO/3019-2

T7B
T7BS
T7BB
T7BBS
T67CB
T67DB
T67EB

SAE 4 bolts
J518c - ISO/DIS 6162-1
Pressure
1" or 3/4"
1" or 3/4"

2" 1/2

P1
1" or 3/4"
1" or 3/4"

P2
3/4"
3/4"

3.9

2" 1/2

1"

3/4"

80.7

9.1

3"

1" 1/4

3/4"

121.0

23.8

3" 1/2

1" 1/2

3/4"

134.5

11.5

4"

220.4

26.1

4"

P1
1"1/4
1"1/2

P2
1"
1"1/4

P3
3/4"
3/4"

Back to Content
9

FORMULAS - T7 AND T67 SERIES INDUSTRIAL APPLICATION

FLUID POWER FORMULAS


Pump input torque

lbs. in.

Pump input power

HP

Pump output flow

U.S. gpm

Fluid motor speed

rpm

pressure (PSI) x displacement (in3 rev )


2 x mech. eff.
speed (rpm) x displacement (in3 rev) x pressure (PSI)
395934 x overall eff.
speed (rpm) x displacement (in3 rev) x volumetric eff.
231
231 x flow rate (U.S. gpm) x volumetric eff.

displacement(in3 rev.)
Fluid motor torque

lbs. in.

Fluid motor power

HP

pressure (PSI) x displacement (in3 rev) x mech. eff.


2
speed (rpm) x displacement (in3 rev) x pressure (PSI) x overall eff.
395934

Back to Content
10

NOTES - T7 AND T67 SERIES INDUSTRIAL APPLICATION

Back to Content
11

ORDERING CODE - T7B AND T7BS SERIES

Model No

T7B or T7BS - B10 - 1 R 00 - A 1 M0


Modifications

T7B series - ISO 2 bolts 3019-2


100A2 HW
T7BS series - SAE B 2 bolts
Mounting flange J744c

Mounting w/connection variables


Metric thread
T7B - T7BS

Cam ring
(Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM

UNC thread
T7BS

M0

M1

00

01

1"

3/4"

1"

3/4"

1"1/2

1"1/2

1"1/2

1"1/2

Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)

Type of shaft - T7B


2 = keyed (ISO R775)

Design letter

Type of shaft - T7BS


1 = keyed (SAE B)
3 = splined (SAE B)
4 = splined (SAE BB)

Porting combination
00 = standard

Direction of rotation (view on shaft end)


R = clockwise
L = counter-clockwise

P = Pressure port
S = Suction port

INTERNAL LEAKAGE (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

NOISE LEVEL (TYPICAL)


T7B - B10

Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
viscosity if internal leakage is higher than 50% of theoretical
flow.

Pressure p [PSI]

PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]

Speed n [RPM]
Maximum permissible axial load Fa = 180 Lbs

Back to Content
12

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 50.7 Lbs - T7B AND T7BS SERIES

Model
T7B
T7BS

Code
M0
M1
00
01

A
M10
.75 deep

B
M12
.88 deep

3/8-16 UNC
.75 deep

1/2-13 UNC
.88 deep

C
1.03
.87
1.03
.87

D
2.06
1.87
2.06
1.87

E
1.00
.75
1.00
.75

F
5.50
5.50
5.75
5.75

G
2.75
2.75
2.87
2.87

H
.55
.55
.56
.56

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Series

Volumetric
Speed
displacement Vi n [RPM]

Flow qv [GPM]
Input power P [HP]
p = 0 PSI
p = 2000 PSI p = 4650 PSI p = 100 PSI p = 2000 PSI p = 4650 PSI
B02
.35 in3/rev
1200
1.84
1.41
0.27
2.54
1800
2.76
2.33
1.73
0.74
4.02
8.59
B03
.60 in3/rev
1200
3.11
2.68
2.08
0.34
4.02
9.06
1800
4.66
4.23
3.63
0.85
6.24
13.75
B04
.78 in3/rev
1200
4.06
3.63
3.03
0.40
5.13
11.64
1800
6.09
5.66
5.06
0.94
7.90
17.62
B05
.97 in3/rev
1200
5.04
4.61
4.01
0.45
6.27
14.31
1800
7.56
7.13
6.53
1.02
9.62
21.62
B06
1.21 in3/rev
1200
6.28
5.85
5.25
0.53
7.71
17.66
1800
9.42
8.99
8.39
1.13
11.79
26.66
B07
1.37 in3/rev
1200
7.13
6.70
6.10
0.58
8.71
19.98
1800
10.70
10.27
9.67
1.20
13.29
30.14
B08
1.52 in3/rev
1200
7.89
7.46
6.86
0.62
9.60
22.05
1800
11.84
11.41
10.81
1.27
14.62
33.24
B10
1.94 in3/rev
1200
10.08
9.65
9.05
0.75
12.15
27.98
1800
15.12
14.69
14.09
1.46
18.45
42.14
B12
2.50 in3/rev
1200
13.00
12.57
12.031)
0.92
15.56
33.591)
1800
19.50
19.07
1.72
23.55
18.541)
50.581)
3
2)
B15
3.05 in /rev
1200
15.85
15.42
14.95
1.08
18.89
38.112)
1800
23.78
23.35
1.97
28.55
22.882)
57.352)
- We do not recommand to use the B02 cartridge at 4650 PSI & 1800 RPM as the internal leakage is over 50% of theoretical flow.
1)
2
B12 = 4350 PSI max. int.
) B15 = 4060 PSI max. int.

Back to Content
13

ORDERING CODE - T7BB - T7BBS SERIES

Model No.

T7BB or T7BBS - B10 - B10 - 1 R 00 - A 1 M1 -

T7BB series - ISO 2 bolts


100A2HW
T7BBS series - SAE B 2 bolts
Mounting flange J744c

Modifications
P1

Mounting w/connection variables

P2

Cam ring for "P1" and "P2"


(Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM

P1
P2
S

Metric thread
T7BB - T7BBS
M0
M1
1"
3/4"
3/4"
3/4"
2"1/2
2"1/2

UNC thread
T7BBS
00
01
1"
3/4"
3/4"
3/4"
2"1/2 2"1/2

Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire
resistant fluids)

Type of shaft T7BB


5 = keyed (ISO R775)
Type of shaft T7BBS
1 = keyed (non SAE)
2 = keyed (SAE BB)
3 = splined (SAE B)
4 = splined (SAE BB)

Design letter
Porting combination (see page 30)
00 = standard
Direction of rotation (view on shaft end)
R = clockwise
L = counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

NOISE LEVEL (TYPICAL)


T7BB - B10 - B10

Pressure p [PSI]
Double pump noise level is given with each section discharging at
the pressure noted on the curve.

PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
viscosity if internal leakage is higher than 50% of theoretical
flow.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]
Total hydromechanical power loss is the sum of each section at
its operating conditions.

Speed n [RPM]
Maximum permissible axial load Fa = 180 Lbs

Back to Content
14

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 71.9 Lbs - T7BB AND T7BBS SERIES

Model
T7BB
T7BBS

Code
M0
M1
00
01

A
M10
.75 deep

B
M12
.88 deep

3/8-16 UNC
.75 deep

1/2-13 UNC
.88 deep

C
1.03
.87
1.03
.87

D
2.06
1.87
2.06
1.87

E
1.00
.75
1.00
.75

F
5.50
5.50
5.75
5.75

G
2.75
2.75
2.87
2.87

H
.55
.55
.56
.56

Shaft torque limits [in3/rev x PSI]


OPERATING CHARACTERISTICS - TYPICAL [115 SUS]
Pressure
port

Series

Volumetric
displacem. Vi

Flow qv [GPM] & n = 1800 RPM


p = 0 PSI p = 2000 PSI p = 4650 PSI
B02
.35 in3/rev
2.76
2.33
1.73
B03
.60 in3/rev
4.66
4.23
3.63
B04
.78 in3/rev
6.09
5.66
5.06
P1
B05
.97 in3/rev
7.56
7.13
6.53
3
9.42
8.99
8.39
B06
1.21 in /rev
&
B07
1.37 in3/rev
10.70
10.27
9.67
P2
B08
1.52 in3/rev
11.84
11.41
10.81
B10
1.94 in3/rev
15.12
14.69
14.09
19.50
19.07
18.541)
B12
2.50 in3/rev
B15
3.05 in3/rev
23.78
23.35
22.882)
2
1) B12 = 4350 PSI max. int.
) B15 = 4060 PSI max. int.

Pump
T7BB

Shaft
1

V x p max.
12666

Input power P [HP] & n = 1800 RPM


p = 100 PSI p = 2000 PSI p = 4650 PSI
0.74
4.02
8.59
0.85
6.24
13.75
0.94
7.90
17.62
1.02
9.62
21.62
1.13
11.79
26.66
1.20
13.29
30.14
1.27
14.62
33.24
1.46
18.45
42.14
1.72
23.55
50.581)
1.97
28.55
57.352)

Back to Content
15

ORDERING CODE - T67CB SERIES

Model No.

T67CB W - 010 - B10 - 1 R 00 - A 1 M1 -

Series - SAE B 2 bolts


Mounting flange J744c

Modifications
P1

P2

Mounting w/connection variables


11 = 4 bolts SAE flanges
(J518c) UNC thread
M1 = 4 bolts SAE flanges
(J518c) Metric thread

Use for severe duty shaft only


Cam ring for "P1"
(Delivery at 0 PSI & 1200 RPM)
003 = 3.42 GPM 017 = 18.48 GPM
005 = 5.45 GPM 020 = 20.23 GPM
006 = 6.75 GPM 022 = 22.29 GPM
008 = 8.37 GPM 025 = 25.14 GPM
010 = 10.81 GPM 028 = 28.15 GPM
012 = 11.76 GPM 031 = 31.70 GPM
014 = 14.58 GPM

Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire
resistant fluid)
Design letter

Cam ring for "P2"


(Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM
Type of shaft
1 = keyed (non SAE)
3 = splined (SAE BB)
5 = splined (SAE B)

Porting combination (see page 30)


00 = standard
Direction of rotation (view on shaft end)
R = clockwise
L = counter-clockwise

Type of shaft - W severe duty


2 = keyed (SAE BB)

INTERNAL LEAKAGE (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

NOISE LEVEL (TYPICAL)


T67CB - 014 - B03

Pressure p [PSI]
Double pump noise level is given with each section discharging at
the pressure noted on the curve.

PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
viscosity if internal leakage is higher than 50% of theoretical
flow.
Total leakage is the sum of each section loss at its operating
conditions.
HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]
Total hydromechanical power loss is the sum of each section at
its operating conditions.

Speed n [RPM]
Maximum permissible axial load Fa = 180 Lbs

Back to Content
16

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 57.3 Lbs - T67CB SERIES

Shaft torque limits [in3/rev x PSI]


Pump
T67CB

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure
port

Series

Shaft
1
2
5

V x p max.
12666
18972
18246

Volumetric
displacem. Vi

Flow qv [GPM] & n = 1800 RPM


Input power P [HP] & n = 1800 RPM
p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI
003
.66 in3/rev
5.14
3.85
2.11
8.45
005
1.05 in3/rev
8.18
6.89
5.68
2.29
12.00
19.81
10.13
8.84
7.63
2.40
14.28
23.79
006
1.30 in3/rev
008
1.61 in3/rev
12.55
11.26
10.05
2.54
17.11
28.75
010
2.08 in3/rev
16.22
14.93
13.71
2.76
21.38
36.22
012
2.26 in3/rev
17.64
16.35
15.14
2.84
23.05
39.14
P1
21.88
20.59
19.37
3.09
27.99
47.78
014
2.81 in3/rev
017
3.56 in3/rev
27.73
26.44
25.22
3.43
34.81
59.73
020
3.89 in3/rev
30.34
29.05
27.84
3.58
37.86
65.07
022
4.29 in3/rev
33.43
32.14
30.93
3.76
41.47
71.38
37.71
36.42
35.21
4.01
46.46
80.12
0251) 4.84 in3/rev
0281) 5.42 in3/rev
42.23
40.94
40.322)
4.27
51.74
76.732)
0311) 6.10 in3/rev
47.56
46.27
45.652)
4.58
57.95
86.062)
p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI
2.76
2.33
1.80
0.74
4.02
8.10
B02
.35 in3/rev
B03
.60 in3/rev
4.66
4.23
3.70
0.85
6.24
12.93
B04
.78 in3/rev
6.09
5.66
5.13
0.94
7.90
16.55
B05
.97 in3/rev
7.56
7.13
6.60
1.02
9.62
20.29
9.42
8.99
8.46
1.13
11.79
25.00
B06
1.21 in3/rev
P2
B07
1.37 in3/rev
10.70
10.27
9.74
1.20
13.29
28.26
B08
1.52 in3/rev
11.84
11.41
10.88
1.27
14.62
31.15
B10
1.94 in3/rev
15.12
14.69
14.16
1.46
18.45
39.48
19.50
19.07
18.54
1.72
23.55
50.58
B12
2.50 in3/rev
B15
3.05 in3/rev
23.78
23.35
22.883)
1.97
28.55
57.353)
- We do not recommand to use this 003 at 4000 PSI & 1800 RPM as the internal leakage is over 50% of theoretical flow
1)
2)
3)
025 - 028 - 031 = 2500 RPM max.
028 - 031 = 3000 PSI max. int.
B15 = 4060 PSI max. int.

Back to Content
17

ORDERING CODE - T67DB SERIES

Model No.

T67DB W - 045 - B10 - 1 R 00 - A 1 M1 Modifications

Series - SAE C 2 bolts


Mounting flange J744c

P1

P2

Mounting w/connection variables


11 = 4 bolts SAE flanges
(J518c) UNC thread
M1 = 4 bolts SAE flanges
(J518c) metric thread

Use for severe duty shaft only


Cam ring for "P1"
(Delivery at 0 PSI & 1200 RPM)
014 = 15.09 GPM 035 = 35.19 GPM
017 = 18.45 GPM 038 = 38.14 GPM
020 = 20.92 GPM 042 = 43.12 GPM
024 = 25.20 GPM 045 = 46.19 GPM
028 = 28.44 GPM 050 = 50.09 GPM
031 = 31.17 GPM

Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)
Design letter

Cam ring for "P2"


(Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM
Type of shaft
1 = keyed (SAE C)
2 = keyed (non SAE)
3 = splined (SAE C)
4 = splined (non SAE)

Porting combination (see page 30)


00 = standard
Direction of rotation (view on shaft end)
R = clockwise
L = counter-clockwise

Type of shaft - W severe duty


5 = keyed (non SAE)

INTERNAL LEAKAGE (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

NOISE LEVEL (TYPICAL)


T67DB - 038 - B04

Pressure p [PSI]
Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
Double pump noise level is given with each section discharging at
viscosity if internal leakage is higher than 50% of theoretical flow. the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]
Total hydromechanical power loss is the sum of each section at
its operating conditions.

Speed n [RPM]
Maximum permissible axial load Fa = 270 Lbs

Back to Content
18

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 80.7 Lbs - T67DB SERIES

Shaft torque limits [in3/rev x PSI]


Pump
T67DB

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure
port

P1

Series

Volumetric
displacem. Vi

014
017
020
024
028
031
035
038
0421)
0451)
0501)

2.90 in3/rev
3.55 in3/rev
4.03 in3/rev
4.85 in3/rev
5.47 in3/rev
6.00 in3/rev
6.77 in3/rev
7.34 in3/rev
8.30 in3/rev
8.89 in3/rev
9.64 in3/rev

B02
.35 in3/rev
B03
.60 in3/rev
B04
.78 in3/rev
B05
.97 in3/rev
B06
1.21 in3/rev
P2
B07
1.37 in3/rev
B08
1.52 in3/rev
B10
1.94 in3/rev
B12
2.50 in3/rev
B15
3.05 in3/rev
1) 042 - 045 - 050 = 2200 RPM max.

Shaft
1
2

V x p max.
38299
30638

Flow qv [GPM] & n = 1800 RPM


Input power P [HP] & n = 1800 RPM
p = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI
22.64
20.46
18.82
4.02
29.31
49.34
27.68
25.50
23.86
4.31
35.20
59.64
31.39
29.21
27.57
4.53
39.52
67.21
37.81
35.63
33.99
4.91
47.02
80.32
42.66
40.48
38.84
5.19
52.68
90.23
46.75
44.57
42.93
5.43
57.45
98.58
52.79
50.61
48.97
5.78
64.50
110.91
57.21
55.03
53.39
6.04
69.66
119.94
64.68
62.50
60.86
6.47
78.37
135.19
69.29
67.11
65.47
6.74
83.75
144.61
75.14
72.96
71.782)
7.08
90.58
134.542)
p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI
2.76
2.33
1.80
0.74
4.02
8.10
4.66
4.23
3.70
0.85
6.24
12.93
6.09
5.66
5.13
0.94
7.90
16.55
7.56
7.13
6.60
1.02
9.62
20.29
9.42
8.99
8.46
1.13
11.79
25.00
10.70
10.27
9.74
1.20
13.39
28.26
11.84
11.41
10.88
1.27
14.62
31.15
15.12
14.69
14.16
1.46
18.45
39.48
19.50
19.07
18.54
1.72
23.55
50.58
23.78
23.55
22.883)
1.97
28.55
57.353)
2)
3
050 = 3000 PSI max. int.
) B15 = 4060 PSI max. int.

Back to Content
19

ORDERING CODE - T67EB SERIES

Model No.

T67EB - 066 - B03 - 1 R 00 - A 1 01 -

Series - SAE C 2 bolts


Mounting flange J744c

Modifications
P1

P2

Mounting w/connection variables


01 = 4 bolts SAE flanges
(J518c) UNC thread
M1 = 4 bolts SAE flanges
(J518c) Metric thread

Cam ring for "P1"


(Delivery at 0 PSI & 1200 RPM)
042 = 41.94 GPM 062 = 62.36 GPM
045 = 45.15 GPM 066 = 67.62 GPM
050 = 50.25 GPM 072 = 72.00 GPM
052 = 52.25 GPM

Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)

Cam ring for "P2"


(Delivery 0 PSI & 1200 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM

Design letter
Porting combination (see page 30)
00 = standard

Type of shaft
1 = keyed (SAE CC)
2 = keyed (non SAE)
3 = splined (SAE C)
4 = splined (SAE CC)

Direction of rotation (view on shaft end)


R = clockwise
L = counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

NOISE LEVEL (TYPICAL)


T67EB - 050 - B03

Pressure p [PSI]
Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
Double pump noise level is given with each section discharging at
viscosity if internal leakage is higher than 50% of theoretical flow. the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]
Total hydromechanical power loss is the sum of each section at
its operating conditions.

Speed n [RPM]
Maximum permissible axial load Fa = 449 Lbs

Back to Content
20

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 121.0 Lbs - T67EB SERIES

Shaft torque limits [in3/rev x PSI]


Pump
T67EB

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure Series Volumetric
Flow qv [GPM] & n = 1800 RPM
port
displacem. Vi p = 0 PSI p = 2000 PSI p = 3500 PSI
042
8.07 in3/rev
62.92
60.37
58.52
045
8.69 in3/rev
67.72
65.17
63.32
050
9.67 in3/rev
75.38
72.83
70.98
P1
052
10.06 in3/rev
78.37
75.82
73.97
93.54
90.99
89.14
062
12.00 in3/rev
066
13.02 in3/rev
101.44
98.89
97.04
072
13.86 in3/rev
108.00
105.45
103.60
p = 0 PSI p = 2000 PSI p = 4350 PSI
2.76
2.33
1.80
B02
.35 in3/rev
B03
.60 in3/rev
4.66
4.23
3.70
B04
.78 in3/rev
6.09
5.66
5.13
B05
.97 in3/rev
7.56
7.13
6.60
9.42
8.99
8.46
B06
1.21 in3/rev
P2
B07
1.37 in3/rev
10.70
10.27
9.74
B08
1.52 in3/rev
11.84
11.41
10.88
B10
1.94 in3/rev
15.12
14.69
14.16
19.50
19.07
18.54
B12
2.50 in3/rev
B15
3.05 in3/rev
23.78
23.35
22.881)
1) B15 = 4060 PSI max. int.

Shaft
2
3

V x p max.
30638
54207

Input power P [HP] & n = 1800 RPM


p = 100 PSI p = 2000 PSI p = 3500 PSI
8.09
78.44
133.80
8.37
84.04
143.60
8.82
92.97
159.24
8.99
96.47
165.36
9.88
114.17
196.34
10.34
123.38
212.46
10.72
131.04
225.86
p = 100 PSI p = 2000 PSI p = 4350 PSI
0.74
4.02
8.10
0.85
6.24
12.93
0.94
7.90
16.55
1.02
9.62
20.29
1.13
11.79
25.00
1.20
13.29
28.26
1.27
14.62
31.15
1.46
18.45
39.48
1.72
23.55
50.58
1.97
28.55
57.351)

Back to Content
21

ORDERING CODE & OPERATING CHARACTERISTICS - T67DBB SERIES

Model No.

T67DBB - 038 - B10 - B10 - 1 R 00 - A 1 - M1 -

Series - SAE C 2 bolts


Mounting flange J744c

P1

P2

P3

Cam ring for "P1"


(Delivery at 0 PSI & 1200 RPM)
014 = 15.09 GPM
017 = 18.45 GPM
020 = 20.92 GPM
024 = 25.20 GPM
028 = 28.44 GPM
031 = 31.17 GPM
035 = 35.19 GPM
038 = 38.14 GPM
042 = 43.12 GPM
045 = 46.19 GPM
050 = 50.09 GPM

Modifications
Mounting w/connection variables
01 = 4 bolts SAE flanges
(J518c) UNC thread
M1 = 4 bolts SAE flanges
(J518c) Metric thread
Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)
Design letter
Porting combination (see pages 30 & 31)
00 = standard

Cam ring for "P2" & "P3"


(Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM
B03 = 3.11 GPM
B04 = 4.06 GPM
B05 = 5.04 GPM
B06 = 6.28 GPM
B07 = 7.13 GPM
B08 = 7.89 GPM
B10 = 10.08 GPM
B12 = 13.00 GPM
B15 = 15.85 GPM

Direction of rotation (view on shaft end)


R = clockwise
L = counter-clockwise
Type of shaft
1 = keyed (non SAE)
2 = keyed (SAE CC)
3 = splined (SAE C)
4 = splined (SAE CC)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure
port

P1

Series

Volumetric
displacem. Vi

014
017
020
024
028
031
035
038
0421)
0451)
0501)

2.90 in3/rev
3.55 in3/rev
4.03 in3/rev
4.85 in3/rev
5.47 in3/rev
6.00 in3/rev
6.77 in3/rev
7.34 in3/rev
8.30 in3/rev
8.89 in3/rev
9.64 in3/rev

B02
.35 in3/rev
B03
.60 in3/rev
B04
.78 in3/rev
B05
.97 in3/rev
B06
1.21 in3/rev
P2
&
B07
1.37 in3/rev
P3
B08
1.52 in3/rev
B10
1.94 in3/rev
B12
2.50 in3/rev
B15
3.05 in3/rev
1) 042 - 045 - 050 = 2200 RPM max. 2)

Flow qv [GPM] & n = 1800 RPM


Input power P [HP] & n = 1800 RPM
p = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI
22.64
20.46
18.82
4.02
29.31
49.34
27.68
25.50
23.86
4.31
35.20
59.64
31.39
29.21
27.57
4.53
39.52
67.21
37.81
35.63
33.99
4.91
47.02
80.32
42.66
40.48
38.84
5.19
52.68
90.23
46.75
44.57
42.93
5.43
57.45
98.58
52.79
50.61
48.97
5.78
64.50
110.91
57.21
55.03
53.39
6.04
69.66
119.94
64.68
62.50
60.86
6.47
78.37
135.19
69.29
67.11
65.47
6.74
83.75
144.61
75.14
72.96
71.782)
7.08
90.58
134.542)
p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI
2.76
2.33
1.80
0.74
4.02
8.10
4.66
4.23
3.70
0.85
6.24
12.93
6.09
5.66
5.13
0.94
7.90
16.55
7.56
7.13
6.60
1.02
9.62
20.29
9.42
8.99
8.46
1.13
11.79
25.00
10.70
10.27
9.74
1.20
13.29
28.26
11.84
11.41
10.88
1.27
14.62
31.15
15.12
14.69
14.16
1.46
18.45
39.48
19.50
19.07
18.54
1.72
23.55
50.58
23.78
23.35
22.883)
1.97
28.55
57.353)
050 = 3000 PSI max. int. 3) B15 = 4060 PSI max. int.

Back to Content
22

TECHNICAL DATA - T67DBB SERIES

INTERNAL LEAKAGE (TYPICAL)

NOISE LEVEL (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

T67DBB - 038 - B06 - B04

Pressure p [PSI]

Pressure p [PSI]

Do not operate the pump more than 5 seconds at any speed or


Triple pump noise level is given with each section discharging at
viscosity if internal leakage is higher than 50% of theoretical flow. the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]

Total hydromechanical power loss is the sum of each section at


its operating conditions.

Speed n [RPM]

Maximum permissible axial load Fa = 180 Lbs

Back to Content
23

ORDERING CODE & OPERATING CHARACTERISTICS - T67DCB SERIES

Model No.

T67DCB - 038 - 028 - B10 - 1 R 00 - A 1 - M1 -

Series - SAE C 2 bolts


Mounting flange J744c

P1

P2

P3

Cam ring for "P1"


(Delivery at 0 PSI & 1200 RPM)
014 = 15.09 GPM 035 = 35.19 GPM
017 = 18.45 GPM 038 = 38.14 GPM
020 = 20.92 GPM 042 = 43.12 GPM
024 = 25.20 GPM 045 = 46.19 GPM
028 = 28.44 GPM 050 = 50.09 GPM
031 = 31.17 GPM
Cam ring for "P2" (Delivery at 0 PSI & 1200 RPM)
003 = 3.43 GPM 012 = 11.76 GPM 025 = 25.14 GPM
005 = 5.45 GPM 014 = 14.58 GPM 028 = 28.15 GPM
006 = 6.75 GPM 017 = 18.48 GPM 031 = 31.70 GPM
008 = 8.37 GPM 020 = 20.23 GPM
010 = 10.81 GPM 022 = 22.29 GPM
Cam ring for "P3" (Delivery at 0 PSI & 1200 RPM)
B02 = 1.84 GPM B06 = 6.28 GPM B12 = 13.00 GPM
B03 = 3.11 GPM B07 = 7.13 GPM B15 = 15.85 GPM
B04 = 4.06 GPM B08 = 7.89 GPM
B05 = 5.04 GPM B10 = 10.08 GPM

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure
port

Series

Modifications
Mounting w/connection variables
01 = 4 bolts SAE flanges
(J518c) UNC thread
M1 = 4 bolts SAE flanges
(J518c) Metric thread
Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)
Design letter
Porting combination (see pages 30 & 31)
00 = standard
Direction of rotation (view on shaft end)
R = clockwise
L = counter-clockwise
Type of shaft
1 = keyed (non SAE) 3 = splined (SAE C)
2 = keyed (SAE CC) 4 = splined (SAE

Volumetric
displacem. Vi

Flow qv [GPM] & n = 1800 RPM


Input power P [HP] & n = 1800 RPM
p = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI
22.64
20.46
18.82
4.02
29.31
49.34
014
2.90 in3/rev
017
3.55 in3/rev
27.68
25.50
23.86
4.31
35.20
59.64
31.39
29.21
27.57
4.53
39.52
67.21
020
4.03 in3/rev
024
4.85 in3/rev
37.81
35.63
33.99
4.91
47.02
80.32
028
5.47 in3/rev
42.66
40.48
38.84
5.19
52.68
90.23
P1
031
6.00 in3/rev
46.75
44.57
42.93
5.43
57.45
98.58
52.79
50.61
48.97
5.78
64.50
110.91
035
6.77 in3/rev
038
7.34 in3/rev
57.21
55.03
53.39
6.04
69.66
119.94
1)
042
8.30 in3/rev
64.68
62.50
60.86
6.47
78.37
135.19
0451) 8.89 in3/rev
69.29
67.11
65.47
6.74
83.75
144.61
75.14
72.96
71.783)
7.08
90.58
134.543)
0501) 9.64 in3/rev
p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI
003
.66 in3/rev
5.14
3.85
2.11
8.45
005
1.05 in3/rev
8.18
6.89
5.68
2.29
12.00
19.81
10.13
8.84
7.63
2.40
14.28
23.79
006
1.30 in3/rev
008
1.61 in3/rev
12.55
11.26
10.05
2.54
17.11
28.75
010
2.08 in3/rev
16.22
14.93
13.71
2.76
21.38
36.22
012
2.26 in3/rev
17.64
16.35
15.14
2.84
23.05
39.14
P2
21.88
20.59
19.37
3.09
27.99
47.78
014
2.81 in3/rev
017
3.56 in3/rev
27.73
26.44
25.22
3.43
34.81
59.73
020
3.89 in3/rev
30.34
29.05
27.84
3.58
37.86
65.07
022
4.29 in3/rev
33.43
32.14
30.93
3.76
41.47
71.38
37.71
36.42
35.21
4.01
46.46
80.12
0252) 4.84 in3/rev
0282) 5.42 in3/rev
42.23
40.94
40.323)
4.27
51.74
76.733)
0312) 6.10 in3/rev
47.56
46.27
45.653)
4.58
57.95
86.063)
p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI
2.76
2.33
1.80
0.74
4.02
8.10
B02
.35 in3/rev
B03
.60 in3/rev
4.66
4.23
3.70
0.85
6.24
12.93
B04
.78 in3/rev
6.09
5.66
5.13
0.94
7.90
16.55
B05
.97 in3/rev
7.56
7.13
6.60
1.02
9.62
20.29
3
/rev
9.42
8.99
8.46
1.13
11.79
25.00
B06
1.21
in
P3
B07
1.37 in3/rev
10.70
10.27
9.74
1.20
13.29
28.26
B08
1.52 in3/rev
11.84
11.41
10.88
1.27
14.62
31.15
B10
1.94 in3/rev
15.12
14.69
14.16
1.46
18.45
39.48
19.50
19.07
18.54
1.72
23.55
50.58
B12
2.50 in3/rev
B15
3.05 in3/rev
23.78
23.35
22.884)
1.97
28.55
57.354)
- We do not recommand to use the 003 cartridge at 4000 PSI & 1800 RPM as the internal leakage is over 50% of theoretical flow.
1)
042 - 045 - 050 = 2200 RPM max. 2) 025 - 028 - 031 = 2500 RPM max.
3)
028 - 031 - 050 = 3000 PSI max. int. 4) B15 = 4060 PSI max. int.

Back to Content
24

TECHNICAL DATA - T67DCB SERIES

INTERNAL LEAKAGE (TYPICAL)

NOISE LEVEL (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

T67DCB - 038 - 022 - B02

Pressure p [PSI]

Pressure p [PSI]

Do not operate the pump more than 5 seconds at any speed or


Triple pump noise level is given with each section discharging at
viscosity if internal leakage is higher than 50% of theoretical flow. the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]

Total hydromechanical power loss is the sum of each section at


its operating conditions.

Speed n [RPM]

Maximum permissible axial load Fa = 180 Lbs

Back to Content
25

26
DIMENSIONS - Weight : 134.5 Lbs - T67DBB / T67DCB SERIES

Back to Content

Shaft torque limits [in /rev x PSI]


Pump

Shaft

Vi x p max. P1 + P2 + P3

Shaft

Vi x p max. P1 + P2 + P3

T67DBB

38299

54207

T67DCB

58901

58901

27

DIMENSIONS - Weight : 220.4Lbs - T67EDB SERIES

Back to Content

ORDERING CODE & OPERATING CHARACTERISTICS - T67EDB SERIES

Model No.

T67EDB - 062 - 035 - B10 - 1 R 00 - A 1 - P 1 -

Series - 250 B4HW


ISO 3019-2 Mounting flange
Cam ring for "P1"
(Delivery at 0 PSI & 1800 RPM)
042 = 41.94 GPM 062 = 62.36 GPM
045 = 45.15 GPM 066 = 67.62 GPM
050 = 50.25 GPM 072 = 72.00 GPM
052 = 52.25 GPM
Cam ring for "P2"
(Delivery at 0 PSI & 1800 RPM)
014 = 15.09 GPM 035 = 35.19 GPM
017 = 18.45 GPM 038 = 38.14 GPM
020 = 20.92 GPM 042 = 43.12 GPM
024 = 25.20 GPM 045 = 46.19 GPM
028 = 28.44 GPM 050 = 50.09 GPM
031 = 31.17 GPM
Cam ring for "P3"
(Delivery at 0 PSI & 1800 RPM)
B02 = 1.84 GPM B07 = 7.13 GPM
B03 = 3.11 GPM B08 = 7.89 GPM
B04 = 4.06 GPM B10 = 10.08 GPM
B05 = 5.04 GPM B12 = 13.00 GPM
B06 = 6.28 GPM B15 = 15.85 GPM

P1

P2

P3

Modifications
Mounting w/connection variables
4 bolts SAE flanges
(J518c) Metric thread
1 = P3 = 3/4" SAE
Mounting (pump)
P = 4 holes for pedestal mounting
F = Standard mounting
Seal class
1 = S1 (for mineral oil)
4 = S4 (for fire resistant fluids)
5 = S5 (for mineral oil and fire resistant
fluids)
Design letter
Porting combination (see pages 30 & 31)
00 = standard
Direction of rotation (view on shaft end)
R = clockwise
L = counter-clockwise
Type of shaft
1 = keyed (G45N - ISO 3019-2)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]


Pressure Series Volumetric
Flow qv [GPM] & n = 1800 RPM
Input power P [HP] & n = 1800 RPM
port
displacem. Vi p = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI
62.92
60.37
58.52
8.09
78.44
133.8
042
8.07 in3/rev
045
8.69 in3/rev
67.72
65.17
63.32
8.37
84.04
143.60
75.38
72.83
70.98
8.82
92.97
159.24
050
9.67 in3/rev
P1
052
10.06 in3/rev
78.37
75.82
73.97
8.99
96.47
165.36
062
12.00 in3/rev
93.54
90.99
89.14
9.88
114.17
196.34
066
13.02 in3/rev
101.44
98.89
97.04
10.34
123.38
212.46
108.00
105.45
103.60
10.72
131.04
225.86
072
13.86 in3/rev
22.64
20.46
18.82
4.02
29.31
49.34
014
2.90 in3/rev
017
3.55 in3/rev
27.68
25.50
23.86
4.31
35.20
59.64
020
4.03 in3/rev
31.39
29.21
27.57
4.53
39.52
67.21
37.81
35.63
33.99
4.91
47.02
80.32
024
4.85 in3/rev
028
5.47 in3/rev
42.66
40.48
38.84
5.19
52.68
90.23
P2
031
6.00 in3/rev
46.75
44.57
42.93
5.43
57.45
98.58
035
6.77 in3/rev
52.79
50.61
48.97
5.78
64.50
110.91
57.21
55.03
53.39
6.04
69.66
119.94
038
7.34 in3/rev
1)
042
8.30 in3/rev
64.68
62.50
60.86
6.47
78.37
135.19
0451) 8.89 in3/rev
69.29
67.11
65.47
6.74
83.75
144.61
0501) 9.64 in3/rev
75.14
72.96
71.782)
7.08
90.58
134.542)
p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI
B02
.35 in3/rev
2.76
2.33
1.80
0.74
4.02
8.10
B03
.60 in3/rev
4.66
4.23
3.70
0.85
6.24
12.93
B04
.78 in3/rev
6.09
5.66
5.13
0.94
7.90
16.55
7.56
7.13
6.60
1.02
9.62
20.29
B05
.97 in3/rev
B06
1.21 in3/rev
9.42
8.99
8.46
1.13
11.79
25.00
P3
B07
1.37 in3/rev
10.70
10.27
9.74
1.20
13.29
28.26
B08
1.52 in3/rev
11.84
11.41
10.88
1.27
14.62
31.15
15.12
14.69
14.16
1.46
18.45
39.48
B10
1.94 in3/rev
B12
2.50 in3/rev
19.50
19.07
18.54
1.72
23.55
50.58
B15
3.05 in3/rev
23.78
23.35
22.883)
1.97
28.55
57.353)
2)
3)
1) 042 - 045 - 050 = 2200 RPM max.
050 = 3000 PSI max. int.
B15 = 4060 PSI max. int.

Back to Content
28

TECHNICAL DATA - T67EDB SERIES

INTERNAL LEAKAGE (TYPICAL)

NOISE LEVEL (TYPICAL)

Internal leakage Qs [GPM]

Lp. Noise level [db(A)] 1m ISO 4412

T67EDB - 062 - 035 - B04

Pressure p [PSI]

Pressure p [PSI]

Do not operate the pump more than 5 seconds at any speed or


Triple pump noise level is given with each section discharging at
viscosity if internal leakage is higher than 50% of theoretical flow. the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
PERMISSIBLE RADIAL LOAD

Load F [Lbs]

Power loss Ps [HP]

HYDROMECHANICAL POWER LOSS (TYPICAL)

Pressure p [PSI]

Total hydromechanical power loss is the sum of each section at


its operating conditions.

Speed n [RPM]

Maximum permissible axial load Fa = 449 Lbs

Back to Content
29

PORTING DIAGRAMS - T67 SERIES INDUSTRIAL APPLICATION

T7BB - T67CB - T67DB - T67EB

T67DBB, T67DCB & T67EDB

Back to Content
30

PORTING DIAGRAMS - T67 SERIES INDUSTRIAL APPLICATION

T67DBB, T67DCB & T67EDB

Back to Content
31