SANDWICH

PANELS
FOR WALLS
AND ROOFS
BUILDING LIFETIME EFFICIENCY
www.ruukki.com/sandwichpanels
Focus on green efciency.
And save money.
Ruukki

energy panels
Airtight top technology
The new Ruukki energy panel solution consists of airtight Ruukki energy panels,
structural details, accessories, airtightness instructions and installation services.
Save up to 30% in yearly energy costs
The new energy panel solution creates savings in heating costs, leading in turn
to significantly reduced carbon dioxide emissions generated by the use of the
building. A building that utilizes the energy panel solution will also receive higher
LEED* and BREEAM* credits.
Ruukkis airtightness promise seals the deal
As the only manufacturer, Ruukki is able to promise an exact airtightness level for
a building. The guarantee is agreed upon case-by-case in a separate contract.
Choosing Ruukkis airtight energy panel solution will increase the value of
your property.
* Voluntary certificates assessing the environmental impact of a building
One panel many options
for customer buildings
Ruukki sandwich panel comes in different core
materials (PU, PIR, W and S) and thicknesses, va-
rious proling shapes and coatings, many standard
and non-standard colours, as well as options for the
vertical or horizontal installation of wall panels.
All this gives our customers freedom to choose the
wall and roof cladding they want according to their
project requirements.
Comprehensive panel system
delivery and much more
Ruukki, as one of only a few sandwich panel pro-
ducers, can provide a customer with a total panel
package starting from design tailored to the
customers needs, through selection of the right
panel type, freedom of choosing a range of product
features and specifying essential accessories to a
speedy and efcient installation service.
Safety - first and foremost
Ruukki sandwich panels offer excellent re safety
properties, especially the panels with a mineral wool
core, which boast exceptional re safety properties,
as well as acoustic insulation. The most recent
Ruukkis achievement: our PIR wall sandwich panels
have EI 30/EW 60 ratings, one of the best results in
terms of re safety in the European market!
Time-constant thermal insulation
Ruukki panels provide excellent thermal insulation.
Air-tight cladding reduces the maintenance costs of
a building, such as heating, cooling and air condi-
tioning, and consequently the release of CO
2
into
the atmosphere.
For a building to last
Ruukki panels, thanks to their high quality core and
cladding materials, and innovative glueing system,
boast excellent durability, corrosion resistance,
thermal insulation and mechanical properties. Our
calculated strength tables allow the quick and easy
selection of panels suitable for a particular build-
ing. With Ruukki panels even dark colours can be
successfully used. Our panels as rst on the market
have achieved the highest atmospheric-corrosivity
category C5-M. With our panels customers buildings
will live longer.
Sandwich panels for walls and roofs
New energy panel solution ENERGY
The main advantage of new energy panels is
their higher airtightness and thermal insula-
tion comparing to traditional sandwich panels.
High class joint tightness is achieved thanks
to the use of special ENERGY gasket and
production process with minimal engineering
tolerances.
Special attention is also paid to production
quality control in order to achieve superior
airtightness up to passive house standard.
New energy panels are offered in three airtight-
ness classes dened as Basic, Plus and Premium
levels. Ruukki energy panels are the basis of Plus
and Premium levels, for which air leakage gures
are respectively n
50
0,9 l/h and n
50
0,6 l/h.
For these two levels Ruukki gives a promise that
specied values will not be exceeded. In case of
Basic level, Ruukkis traditional sandwich panels
are used and air leakage gure is n
50
1,3 l/h.
New group of sandwich panels
with mineral wool core
Increasingly stricter requirements as to thermal
insulation of buildings force construction mate-
rial manufacturers to search for new solutions
and focus on further improvement of their
products.
In order to meet these requirements and to fulll
our customers expectations we developed a new
offer of sandwich panels with the core made of
mineral wool - SP2D WE and SPB WE. These new
panels feature a core with lower density. The
cores physical and mechanical properties ensure
proper strength, what is reected in relevant
strength tables.
Very low thermal conductivity allows to im-
prove signicantly thermal parameters of walls
made with the use of new sandwich panels.
New panels with mineral wool core are a perfect
solution for envelopes that must meet high
requirements as to energy efciency.
4
Ruukki SP2D PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and
facilitates assembly.
4. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel xings ensure aesthetic facade appearance.
7. Properly proled edges improve thermal insulation and joint tightness.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Gas permeable polyurethane seal.

Ruukki SPF PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and facili-
tates assembly.
4. Properly proled edges improve thermal insulation and joint tightness.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel xings ensure aesthetic facade appearance.
7. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Narrow, almost invisible 1 mm gap.

1
the surface of plain prole can be slightly corrugated min. facing thickness 0.50 mm.
2
other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult con-
struction department of panels producer.


Ruukki SP2D PU
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
R28 ribbed
L linear
P embossed
F flat
1
M microprofiled
L linear
F flat
1
RL, RF, PL, PF,
ML, MF, LL, LF,
FL, FF
1015, 3013, 5005, 6011,
7016, 7035, 9002, 9006,
9007, 9010
9002, 9010
11.0 11.7 10.3
see point
2
60 80 100
0.35 0.26 0.21
24
1050
18,5
1000
0.50
Ruukki SPF PU
rigid polyurethane
foam
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
S sinusoidal
SL, SF
9006
9010
98 / 80
15.3
0.022 0.022
see point
2
L linear
F flat
1
0.23
B-s3, d0
25
18.5
963.5
900
0.60
0.55
core
thickness
[mm]
weight
[kg/m
2
]
value
[W/mK]
U value
[W/m
2
K]
4

reaction to fire
sound
insulation [dB]
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
certificates
and approvals
external facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
5
standard colours of
internal facing
RAL
other colours
internal facing
thickness [mm]
internal facing
profiling
rigid polyurethane
foam
B-s2,d0
0.40
18.5
Sandwich panels for walls and roofs
3
only for partition walls.
4
U value includes impact of linear thermal bridge appearing on panel joint.
5
Facing colour groups is in the table on page 19.
Ruukki SP2E PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. 3 mm gap enables additional joint closure with durably elastic mass (p.8).
3. Precisely milled labyrinth core edge eliminates thermal bridges.
4. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
5. Butyl sealing compound eliminates air and moisture penetration, applied at
building site.
6. Facing prole conforming with the standards applicable to cooling and food
industries ensures uniform facade appearance.
7. Rigid, HCFC-free and self-extinguishing environmentally and ozone friendly
polyurethane foam core of excellent thermal insulation.
8. Durably elastic sealing compound (compulsory for ceilings, optional for walls),
applied at building site.
Ruukki SP2B PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and faci-
litates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries etc.).
5. Properly proled edges improve thermal insulation parameters and joint
tightness.
6. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
7. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (continuous thermal parameters of panels).
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.
Ruukki SP2B PU
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
R28 ribbed
L linear
P embossed
F flat
1
M microprofiled
R28 ribbed
L linear
P embossed
F flat
1
M microprofiled
RL, RF, PL, PF,
ML, MF, LL, LF,
FF
3
1015, 3013, 5005, 6011,
7016, 7035, 9002, 9006,
9007, 9010
see point
2
9002, 9010
L linear
F flat
1
60 80 100
9.1 9.9 10.6
0.35 0.26 0.21
24
1120
18.5
1100
0.50
0.40
Ruukki SP2E PU
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
RL, RF, PL, PF,
ML, MF, LL, LF,
FF
3
1015, 3013, 5005, 7035,
9002, 9006, 9007,
9010
see point
2
9002, 9010
L linear
F flat
1
120 160 180 200
11.9 13.4 14.1 14.8
0.17 0.13 0.11 0.10
25
18.5
1120
1100
0.50
0.50
rigid polyurethane
foam
rigid polyurethane
foam
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
sound
insulation [dB]
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
certificates
and approvals
external facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
5
standard colours of
internal facing
RAL
other colours
internal facing
thickness [mm]
internal facing
profiling
40
8.4
0.50
B-s2,d0 B-s2, d0
0.022
0.021
(temp. 0C)
value
[W/mK]
U value
[W/m
2
K]
4

Ruukki SP2D PIR
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and
facilitates assembly.
4. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent re insulation parameters.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel xings ensure aesthetic facade appearance.
7. Properly proled edges improve thermal insulation and joint tightness.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Gas permeable polyurethane seal.

1
the surface of plain prole can be slightly corrugated min. facing thickness 0.50 mm.
2
other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult con-
struction department of panels producer.


Ruukki SP2C PU
1. Large bend radii on facings ensure that none of the protective coat pro-
perties is lost.
2. Facing proling ensures uniform facade appearance.
3. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
4. Aluminium foil prevents gas diffusion and the penetration of vapour
into a polyurethane core (continuous thermal parameters of panels).
5. Auxiliary groove allows for precise assembly.
6. Properly proled edges improve thermal insulation and joint tightness.
7. Specially shaped micro-chamber protects against water capillary pe-
netration.
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.
Ruukki SP2D PIR
Declaration of con-
formity CE acc. to EN
14509
Hygienic
Certificate
HC/97/779/104/2011
L linear
F flat
1
L linear
F flat
1
RL, RF, PL, PF,
ML, MF, LL, LF,
FL, FF
1015, 3013, 5005,
6011, 7035, 9002,
9006, 9007, 9010
9002, 9010
11.2 12.0 10.4
see point
2
60 80 100
0.34 0.25 0.20
24
1050
18.5
1000
0.50 or 0,60
0.40
Ruukki SP2C PU
rigid polyurethane
foam
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
sound
insulation [dB]
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
certificates
and approvals
external facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
6
standard colours of
internal facing
RAL
other colours
internal facing
thickness [mm]
internal facing
profiling
rigid polyiso-
cyanurate foam
T trapezoidal
TL, TF
1015, 3013, 5005,
6011, 7035, 9002,
9006, 9010
80/40
9.5
see point
2
0.46
B-s2,d0
18.5
4
1083
1000
0.50
0.40
100/60 120/80 140/100
10.3 11.0 11.7
0.31 0.24 0.20
24
9002, 9010
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
B
ROOF
(t
1
)
external fire
exposure

160/120 210/170
12.5 14.3
0.17 0.13
R28 ribbed
L linear
P embossed
F flat
1
M microprofiled
value
[W/mK]
U value
[W/m
2
K]
4

0.022 0.021
60-80 B-s2,d0
100 B-s1,d0
Sandwich panels for walls and roofs
3
only for partition walls.
4
on special request up to 21.0 m.
5
U value includes impact of linear thermal bridge appearing on panel joint.
6
Facing colour groups is in the table on page 19.
Ruukki SP2E PIR
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. 3 mm gap enables additional joint closure with durably elastic mass (p.8).
3. Precisely milled labyrinth core edge eliminates thermal bridges.
4. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
5. Butyl sealing compound eliminates air and moisture penetration, applied at
building site.
6. Facing prole conforming with the standards applicable to cooling and food
industries ensures uniform facade appearance.
7. Rigid, HCFC-free and self-extinguishing environmentally and ozone friendly
polyisocyanurate foam core of excellent re insulation.
8. Durably elastic sealing compound (compulsory for ceilings, optional for walls),
applied at building site.
Ruukki SP2B PIR
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and faci-
litates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries etc.).
5. Properly proled edges improve thermal insulation parameters and joint
tightness.
6. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent re insulation parameters.
7. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (continuous thermal parameters of panels).
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.

Ruukki SP2B PIR
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
R28 ribbed
L linear
P embossed
F flat
1
M microprofiled
1015, 3013, 5005, 6011,
7035, 9002, 9006,
9007, 9010
see point
2
9002, 9010
L linear
F flat
1
60 80 100
9.3 10.1 10.9
0.34 0.25 0.20
24
1120
18.5
1100
0.50 or 0.60
Ruukki SP2E PIR
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
RL, RF, LL, ML, LF,
MF, FF
3
1015, 3013, 5005, 6011,
7035, 9002, 9006,
9007, 9010
see point
2
9002, 9010
L linear
F flat
1
R28 ribbed
L linear
F flat
1
M microprofiled
120 160 180 200
12.4 14.0 14.8 15.6
0.16 0.12 0.11 0.10
25
18.5
1120
1100
0,50 or 0.60
0.50
rigid polyisocyanurate
foam
rigid polyisocyanurate
foam
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
sound
insulation [dB]
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
certificates
and approvals
external facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
6
standard colours of
internal facing
RAL
other colours
internal facing
thickness [mm]
internal facing
profiling
40
8.5
0.49
40-80 B-s2,d0
100 B-s1,d0
B-s1,d0
Declaration of con-
formity CE acc. to EN
14509
Hygienic
Certificate
HC/97/779/104/2011
RL, RF, PL, PF,
ML, MF, LL, LF,
FL, FF
3

external fire
exposure
0.40
value
[W/mK]
U value
[W/m
2
K]
4

0.021
0.020
(temp. 0C)
Ruukki SP2C PIR
1. Large bend radii on facings ensure that none of the protective coat pro-
perties is lost.
2. Facing proling ensures uniform facade appearance.
3. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent thermal insulation parameters.
4. Aluminium foil prevents gas diffusion and the penetration of vapour
into a polyurethane core (continuous thermal parameters of panels).
5. Auxiliary groove allows for precise assembly.
6. Properly proled edges improve thermal insulation and joint tightness.
7. Specially shaped micro-chamber protects against water capillary pe-
netration.
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.
1
other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult
construction department of panels producer.
Ruukki SP2D W
1. Core made of rigid, environmentally friendly mineral wool provides
excellent re resistance.
2. Properly milled core improves thermal insulation.
3. Large bend radii on facings ensure that none of the protective coat
properties is lost.
4. Facing proling ensures uniform facade appearance.
5. Double lock from outer and inner sides increases re-tightness and faci-
litates assembly.
6. Auxiliary groove allows for precise assembly.
7. Concealed panel xings ensure aesthetic facade appearance.
8. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
internal facing
thickness [mm]
certificates
and approvals
external facing
profiling
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
4
standard colours of
internal facing
RAL
other colours
Ruukki SP2C PIR
rigid polyisocyanurate
foam
T trapezoidal
TL
1015, 3013, 5005,
6011, 7035, 9002,
9006, 9010
80/40
9.7
see point
1
L linear
0.46
18.5
2
1083
1000
0.50
0.40
100/60 120/80 140/100
10.5 11.3 12.1
0.31 0.24 0.20
24
9002, 9010
Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
Ruukki SP2D W
R28, R250, R500
L linear
M microprofiled
L linear
F flat
RL, ML, LL,
RF, MF, LF
1015, 5005,
7035, 9002, 9006,
9007, 9010
9002, 9010
see point
1
32
1054
12.0 12.0 12.0 10.0
1000
0.60
0.50
100
21.5
0.43
A2-s2, d0
120 140
23.8 26.1
0.35 0.31
Declaration of con-
formity CE acc.
to EN 14509
Hygienic Certificate
HC/97/779/104/2011
hard mineral
wool
sound
insulation [dB]
external fire
exposure
B
ROOF
(t
1
)
160
28.3
0.27
160/120210/170
12.9 14.9
0.17 0.13
value
[W/mK]
U value
[W/m
2
K]
4

0.021 0.043
80/40-120/80 B-s2,d0
140/100-210/170 B-s1,d0
Ruukki SPC W
1. Core made of rigid, environmentally friendly mineral wool provides excel-
lent re resistance.
2. Hump made of environmentally friendly, hard mineral wool.
3. Properly milled core improves thermal insulation and joint tightness.
4. Large bend radii on facings ensure that none of the protective coat pro-
perties is lost.
5. Facing proling ensures uniform facade appearance.
6. The lock from inner side increases re-tightness and facilitates as-
sembly.
7. Specially shaped micro-chamber protects against water capillary pene-
tration.
8. Auxiliary groove allows for precise assembly.
9. Butyl sealing compound (applied at building site) protects against wa-
ter and moisture penetration.
Sandwich panels for walls and roofs
2
on special request up to 21.0 m.
3
U value includes impact of linear thermal bridge appearing on panel joint.
4
Facing colour groups is in the table on page 19.

Ruukki SPB W
1. Large bend radii on facings ensure that none of the protective coat proper-
ties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facili-
tates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of rigid, environmentally friendly mineral wool provides
excellent re resistance.

Ruukki SPB W
R28, R250, R500
(for 1000 mm modular width)
R275, R550 (for 1100 mm
modular width)
L linear, F flat
M microprofiled
RL, ML, LL, FL,
RF, MF, LF, FF
1015, 5005,
7035, 9002, 9006,
9007, 9010
see point
1
9002, 9010
L linear
F flat
L linear
F flat
80 100
18.7 21.0 23.3
0.51 0.41 0.34
1018 lub 1118
8,0
1000 lub 1100
0.60
0.50
120 140
25.6
0.30
32
12,0 12,0 10,0 10,0
Ruukki SPC W
TL, TF
1015, 5005, 7035,
9002, 9006, 9010
see point
1
9002, 9010
T trapezoidal
140/100 190/150
22.0 27.8
0.41 0.28
34
12.0
1059
1000
0.60
0.50
hard mineral
wool
Declaration of conform-
ity CE acc. to Hygienic
Certificate
HC/97/779/104/2011
Declaration of conform-
ity CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
sound
insulation [dB]
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
internal facing
thickness [mm]
certificates
and approvals
external facing
profiling
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
4
standard colours of
internal facing
RAL
other colours
hard mineral
wool
external fire
exposure
B
ROOF
(t
1
)
A2-s2, d0 A2-s2, d0
160 200
27.9 32.5
0.26 0.21
R28, R250, R500
L linear
M microprofiled
value
[W/mK]
U value
[W/m
2
K]
4

0.043 0.043
1
other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it is
advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths resulting
from calculations that take into cosideration thermal loads; in doubtful cases please consult construction
department of panels producer.
Ruukki SP2D WE
1. Core made of soft, environmentally friendly mineral wool provides
excellent re resistance.
2. Properly milled core improves thermal insulation.
3. Large bend radii on facings ensure that none of the protective coat
properties is lost.
4. Facing proling ensures uniform facade appearance.
5. Double lock from outer and inner sides increases re-tightness and faci-
litates assembly.
6. Auxiliary groove allows for precise assembly.
7. Concealed panel xings ensure aesthetic facade appearance.
8. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
Ruukki SPB WE
1. Large bend radii on facings ensure that none of the protective coat proper-
ties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facili-
tates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of soft, environmentally friendly mineral wool provides
excellent re resistance.
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
internal facing
thickness [mm]
certificates
and approvals
external facing
profiling
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
3
standard colours of
internal facing
RAL
other colours
sound
insulation [dB]
external fire
exposure
Ruukki SP2D WE
R28, R250, R500,
L linear
M microprofiled
L linear
F flat
RL, ML, LL,
RF, MF, LF
1015, 5005, 7035,
9002, 9006,
9007, 9010
9002, 9010
see point
1
29
1054
12.0
1000
0.60
0.50
100
19.0
0.40
A2-s1, d0
120
20.8
0.33
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
soft mineral
wool

140 160
22.6 24.4
0.29 0.25
Ruukki SPB WE
soft mineral
wool
R28, R250, R500
(for 1000 mm modular width)
R275, R550 (for 1100 mm
modular width)
L linear, F flat
M microprofiled
RL, ML, LL, FL,
RF, MF, LF, FF
1015, 3013, 5005,
7035, 9002, 9006,
9010
80
16.8
see point
1
L linear
F flat
0.48
A2-s1, d0
8.0
1018 or 1118
1000 or 1100
0.60
0.50
100 120 140
18.6 20.4 22.2
0.39 0.32 0.28
29
9002, 9010
Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
-
160 200
24.0 27.6
0.24 0.20
12.0 10.0 10.0 12.0 10.0 12.0 12.0
value
[W/mK]
U value
[W/m
2
K]
4

0.040 0.040
Ruukki SPB S
1. Large bend radii on facings ensure that none of the protective coat pro-
perties is lost.
2. Facing proling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases re-tightness and faci-
litates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of environmentally friendly polystyrene.
Ruukki SPC S
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing proling ensures uniform facade appearance.
3. Properly milled core improves thermal insulation and joint tightness.
4. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
5. Auxiliary groove allows for precise assembly.
6. Core made of environmentally friendly polystyrene.
7. Specially shaped micro-chamber protects against water capillary
penetration.
8. Hump made of environmentally friendly, natural polystyrene.
Sandwich panels for walls and roofs
core
thickness
[mm]
weight
[kg/m
2
]
reaction to fire
maximum length
[m]
total width
[mm]
modular width
[mm]
external facing
thickness [mm]
internal facing
thickness [mm]
certificates
and approvals
external facing
profiling
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL
3
standard colours of
internal facing
RAL
other colours
sound
insulation [dB]
external fire
exposure
T trapezoidal
Ruukki SPC S
TL
1015, 6011, 7035,
9002, 9006, 9010
see point
1
9002, 9010
140/100
11.0 12.0
0.34
1059
1000
0.50
190/150
0.23
26
18.5
polystyrene
L linear
Declaration of confor-
mity CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
B
ROOF
(t
1
)
B-s3, d0
0.50
Ruukki SPB S
L linear
LL, ML
1015, 6011, 7035, 9002,
9006, 9010
9002, 9010
see point
1
24
1118
12.0
1100
0.50
10.5 9.5 10.0
0.24 0.58
100
0.35
B-s2, d0
L linear
M microprofiled
18.5 18.5 18.5
polystyrene
140 200 60
11.0
0.17
9.8
80
0.44
1.0
Declaration of conform-
ity CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
-
0.50
200
value
[W/mK]
U value
[W/m
2
K]
4

0.037 0.037
2
U value includes impact of linear thermal bridge appearing on panel joint.
3
Facing colour groups is in the table on page 19.

Airtight top technology
Thanks to decades of expertise in sandwich panel pro-
duction, intensive R&D, and comprehensive field mea-
surements, we have succeeded in developing a new
airtight energy panel solution. Utilizing the solution
in a building will result in improved energy efficiency
and savings in maintenance costs.
The energy panel solution consists of new, airtight
Ruukki energy panels, structural details, accessories,
airtightness instructions, as well as installation car-
ried out by a certified Ruukki partner, and comes with
Ruukkis airtightness promise.
Our energy panels feature high-class joint tightness.
The panels are manufactured with minimal engi-
neering tolerances, and special attention is paid to
production quality control in order to achieve superior
airtightness up to passive house standard. Our energy
panel solution is an excellent choice for industrial and
commercial buildings, logistics centers, and warehouses,
for instance. After the installation, final measure-
ments will verify the airtightness of your building.
Financial and ecological benets
The new energy panel solution creates savings in
heating costs, leading in turn to significantly reduced
carbon dioxide emissions generated by the use of the
building. Projects that are constructed in compliance
with the principles of sustainable development will
receive higher LEED* and BREEAM* credits. In addi-
tion to this, the indoor air quality will improve, as the
temperature becomes stabilized with no cold draft.
The value of your property will increase with environ-
mental responsibility and image, high quality, and
lower running costs.
Ruukkis airtightness promise seals the deal
We have absolute faith in the airtightness of our en-
ergy panel solution. As the only manufacturer, Ruukki
is able to promise an exact airtightness level for a
building. The guarantee is agreed upon case-by-case
in a separate contract.
* Voluntary certificates assessing the environmental impact
of a building.
12
PREMIUM
air leakage
rate
n
50
0.6 1/h
PLUS
air leakage
rate
n
50
0.9 1/h
BASIC
air leakage
rate
n
50
1.3 1/ h
Potential savings with Ruukki energy panel solution
Values based on a building located in Poland
H
e
a
t

e
n
e
r
g
y

c
o
n
s
u
m
p
t
i
o
n

(

/
y
e
a
r
)
n
50
= 3 l/h based on
technical conditions to
be fulfilled by buildings
and their location;
buildings with natural
ventilation.
Ruukki Basic
Ruukki Plus
Ruukki Premium
Ruukki energy panel solution
Ruukki energy panels
- SP2B PU/PIR ENERGY
- SP2D PU/PIR ENERGY
- SP2E PU/PIR ENERGY
- SPB W ENERGY, SPB WE ENERGY
- SP2D W ENERGY, SP2D WE ENERGY
Structural details and accessories
Airtightness instructions
Installation carried out by a specialist firm certified by Ruukki
Airtightness levels
Premium and Plus levels are based on the new energy
panel solution, for which an airtightness promise is
given. The Basic level air leakage rate is n
50
= 1.3 1/h.
This can be achieved by using Ruukkis ordinary panel
system.
13
40 000
35 000
30 000
25 000
20 000
15 000
10 000
5000
0
Floor area (m
2
)
1000m
2
2000m
2
3000m
2
4000m
2
6000m
2
8000m
2
10000m
2
7000m
2
Sandwich panels for walls and roofs
Fire resistance

Ruukki SP2E PU
120 160 180 200
EI 15
1
EW 30
2
EI 15
3
EW 20
3
EI 15
1
EW 30
2
EI 15
3
EW 20
3
EI 15
1
EW 30
2
EI 15
3
EW 20
3
EI 15
1
EW 30
2
EI 15
3
EW 20
3

Ruukki SP2D PU
60
E 15
1
80
EI 15
3
EW 30
4
100
EI 15
3
EW 30
4 EW 30
4
EI 15
2
Ruukki SP2B PU
40 60 80 100
EW 30
1
EI 15
2

EI 15
3
EW 30
1
EI 15
3
-
EI 15
3
-
fire
resistance
thickness
[mm]
rigid
polyurethane foam
1
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2
re resistance of load bearing structure min. R15; max. distance between supports 11.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3
re resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 8.6 m vertical assembly arrangement; panel's facings made of stainless steel;
fire
resistance
thickness
[mm]
from
inside
from
outside
1
the inside is exposed to re; re resistance of load bearing structure min. R15; max. distance between supports 11.6 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2
the inside is exposed to re; re resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3
the inside is exposed to re; re resistance of load bearing structure min. R15; max. distance between supports 6.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4
the outside is exposed to re; re resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
fire
resistance
thickness
[mm]
1
re resistance of load bearing structure min. R15; max. distance between supports 10.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3
re resistance of load bearing structure correspondingly min. R15or R20; max. distance between supports 4.0 m horizontal assembly arrangement and 12.0 m vertical arrangement assembly; panel's facings made
of stainless steel;
Sandwich panels for walls and roofs

Ruukki SP2C PU

Ruukki SPF PU
98/80
EI 15
1
EW 30
1
EW 60
2
E 120
2
fire
resistance
thickness
[mm]
1
re resistance of load bearing structure correspondingly min. R15 or R60; span bending moment Md 0.0672 kNm/m; support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration
when doing calculations;
2
re resistance of load bearing structure correspondingly R20 or R30; span bending moment Md 0.0697 kNm/m; support bending moment Md -0.1245 kNm/m; snow load 0.2xS must be taken into consideration
when doing calculations;
3
re resistance of load bearing structure min. R30; span bending moment Md 0.0896 kNm/m; support bending moment Md -0.1600 kNm/m; snow load 0.2xS must be taken into consideration when doing calcula-
tions;
fire
resistance
thickness
[mm]
from
inside
from
outside
1
the inside is exposed to re; re resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2
the outside is exposed to re; re resistance of load bearing structure correspondingly min. R60 or R120; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
80/40
REI 15
1
RE 60
1
REI 20
2
RE 30
2
100/60
REI 15
1
RE 60
1
REI 20
2
RE 30
2
120/80
REI 15
1
RE 60
1
REI 30
3
160/120 140/100
REI 30
3
REI 30
3
REI 15
1
RE 60
1
REI 15
1
RE 60
1

Ruukki SP2C PIR

Ruukki SP2E PIR
120
EI 15
1
EI 30
2
EW 30
2
160
EI 15
1
EI 30
2
EW 30
2
180
EI 15
1
EI 30
2
EW 30
2
200
EI 30
3
EW 30
3
EI 60
4
EW 60
4

Ruukki SP2D PIR
60
EW 30
1
80
EW 30
1
El 15
2
EW 20
2
EI 15
4
EW30
4
100
EW 30
1
EI 15
3
EI 15
4
EW30
4
EI 15
4
EW30
4

Ruukki SP2B PIR
40 60 80 100
EI 15
3
EI 30
4
EW 30
4
EI 15
2
EW 30
2
EW 30
1
EW 30
1
fire
resistance
thickness
[mm]
rigid
polyisocyanurate foam
1
re resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2
re resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
3
re resistance of loadbearingstructure min. R15; max. distance betweensupports 11.9 m horizontal assembly arrangement and4.0 m vertical assembly arrangement; providingthat butyl sealingcompoundis usedonbothlocks of
thepanel;
4
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement; providing that butyl sealing compound is used on both locks of the panel;
fire
resistance
thickness
[mm]
from
inside
from
outside
1
the inside is exposed to re; re resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2
the inside is exposed to re; re resistance of load bearing structure correspondingly min. R15 or R20; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3
the inside is exposed to re; re resistance of load bearing structure min. R15; max. distance between supports 8.8 m vertical assembly arrangement and 4.0 horizontal assembly arrangement;
4
the outside is exposed to re; re resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
fire
resistance
thickness
[mm]
2
re resistance of load bearing structure min. R15; max. distance between supports 12.0 m vertical and horizontal assembly arrangement;
2
re resistance of load bearing structure min. R30; max. distance between supports 8.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3
re resistance of load bearing structure min. R30; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4
re resistance of load bearing structure min. R60; max. distance between supports 9.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement
fire
resistance
thickness
[mm]
1
re resistance of load bearing structure correspondingly min. R15 or R90; span bending moment Md 0.0940 kNm/m; support bending moment Md -0.1680 kNm/m; snow load 0.2xS must be taken into considera-
tion when doing calculations;
2
re resistance of load bearing structure correspondingly min. R20 or R30; span bending moment Md 0.1160 kNm/m; support bending moment Md -0.2070 kNm/m ; snow load 0.2xS must be taken into conside-
ration when doing calculations;
3
re resistance of load bearing structure correspondingly min. R30 or R60; span bending moment Md 0.1210 kNm/m; support bending moment Md -0.2150 kNm/m; snow load 0.2xS must be taken into conside-
ration when doing calculations;
80/40 100/60 120/80 160/120 140/100
REI 30
3
RE 60
3
REI 30
3
RE 60
3
REI 15
1
RE 90
1
REI 15
1
RE 90
1
REI 15
1
RE 90
1
REI 30
3
RE 60
3
REI 15
1
RE 90
1
REI 20
2
RE 30
2
REI 15
1
RE 90
1
REI 20
2
RE 30
2

Sandwich panels for walls and roofs

EI 60
2
EI 90
4
fire
resistance
thickness
[mm]
Ruukki SP2D W
1
the inside is exposed to re; re resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2
the outside is exposed to re; re resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3
the inside is exposed to re; re resistance of load bearing structure min. R60; max. distance between supports 4.0 m horizontal assembly arrangement and 10.5 m vertical assembly arrangement;
4
the outside is exposed to re; re resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
5
the outside is exposed to re; re resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 10.7 m vertical assembly arrangement;
from
inside
from
inside
from
outside
from
outside
fire
resistance
thickness
[mm]
Ruukki SPC W
140/100 190/150
REI 60
1
RE 180
1
1
re resistance of load bearing structure correspondingly min. R60 or R180; span bending moment Md 0.1512 kNm/m, support bending moment Md -0.2700 kNm/m; snow load 0.2xS must be taken into consideration
when doing calculations;
REI 60
1
RE 180
1

fire
resistance
thickness
[mm]
Ruukki SPB W
1
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2
re resistance of load bearing structure min. R60; max. distance between supports 11.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3
re resistance of load bearing structure min. R90; max. distance between supports 10.2 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4
re resistance of load bearing structure min. R120; max. distance between supports 9,9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
hard mineral
wool
100
EI 60
1
EI 90
4
EI 60
1
EI 90
4
EI 60
1
EI 90
4
120 160 140
EI 60
1
EI 60
2
EI 45
3
EI 45
3
EI 90
4
EI 45
3
EI 90
4
EI 45
3
EI 90
4
EI 90
4
EI 120
5
EI 90
4
EI 120
5
EI 90
4
EI 120
5
EI 90
4
EI 120
5
or
80 100 120 200 160 140
EI 60
2
EI 90
3
EI 120
4
EI 60
2
EI 90
3
EI 120
4
EI 60
2
EI 90
3
EI 120
4
EI 60
2
EI 90
3
EI 120
4
EI 60
2
EI 90
3
EI 120
4

EI 30
1
EI 60
2
EI 90
4
EI 60
2
EI 90
4
18

Ruukki SPC S
140/100
RE 60
1
190/150
RE 60
1

Ruukki SPB S
60
-
80
EW 60
1
100
EW 60
1
140
EW 60
1
200
EW 60
1 fire
resistance
thickness
[mm]
rigid polystyrene
1
re resistance of load bearing structure min. R60; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
fire
resistance
thickness
[mm]
1
fire resistance of load bearing structure min. R60; span bending moment Md 0.0672 kNm/m, support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration when doing
calculations;


fire
resistance
thickness
[mm]
Ruukki SPB WE
80 100 120 140
EI 15
1
El 30
2
El 60
3
El 120
4
El 60
3
El 120
4
El 60
3
El 120
4
El 60
3
El 120
4
El 60
3
El 120
4
1
re resistance of load bearing structure min. R15; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3
re resistance of load bearing structure min. R60; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
4
re resistance of load bearing structure min. R120; max. distance between supports 9.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
soft mineral
wool
fire
resistance
thickness
[mm]
Ruukki SP2D WE
100
EI 30
1
El 90
2
El 120
3
120
EI 30
1
1
re resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 11.5 m vertical assembly arrangement;
2
re resistance of load bearing structure min. R90; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
3
re resistance of load bearing structure min. R120; max. distance between supports 4.0 m horizontal assembly arrangement and 10.8 m vertical assembly arrangement;
from
inside
from
outside
160 200
160 140
EI 30 EI 30
1
El 90
2
El 120
3
El 90
2
El 120
3
El 90
2
El 120
3
19
Sandwich panels for walls and roofs

I
II
III
colours colour group
RAL 1015, 7035, 9002, 9010
RAL 9006
RR 20, 21, 24, 30, 40
RAL 3013, 5005, 6011, 7016, 9007
RR 22, 23, 29, 34, 35, 36, 41
Facing colour groups
Accessories Corrosion resistance Facings and coatings
Steel flashings
Standard length: 3000 mm.
Material: zinc-coated steel sheet.
Protective coating: polyester varnish.
Additional protection: foil.
Note: there is a possibility of making individual ashings
up to 6000 mm in length.
Fasteners
Self-drilling:
for hot-rolled structure (walls' thickness 3-12 mm),
for cold-bent structure (thickness 1.5-5 mm).
Note: fasteners are available in galvanized or lacquered -
white versions. On special demand it is possible to provide
hoods or fasteners in external facing colour of a sandwich
panel.
Seals
seals for Ruukki panels.
Other
instruments for installation and lifting of Ruukki pa-
nels,
sealing collars for sealing wire passage (for example venti-
lation) within Ruukki panels,
transparent panels,
socket, pads etc. for Ruukki SP2E PU panels.
Corrosion resistance
On the basis of research carried out, application possibi-
lities for Ruukki sandwich panels with organic coatings/
facings were conrmed in the following environments:
Polyester coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
PVDF coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
Foil coating PVC (F) of 120 m, category C1 to C4 acc.
to EN ISO 12944-2: 2001.
Facing made of stainless steel of 0.55 or 0.60 mm,
C1 to C5-M category acc. to EN ISO 12944-2: 2001.
Special CSafe coating, up to C4 category acc. to EN ISO
12944-2:2001, providing better scratching, corrosion, dirt and
UV resistance as well as improved chemical resistance against
ammonia and sodium hydroxide.
Facings and coatings
Ruukki sandwich panels are made of a structural insulation
core (rigid, HCFC-free, self-extinguishing polyurethane
foam, mineral wool of very good re resistance, or
polystyrene) and two facings made of steel sheet gal-
vanized on both sides with organic coating. Standard
steel sheet is covered with polyester coating of 25 m
thickness in colour compliant to Ruukki sandwich panels
colour scheme. From interior side, steel sheet has a coating
that increases core adherence. On special order we offer
Ruukki sandwich panels made of zinc-coated steel sheets
with the following organic coatings:
PVDF coating of 25 m thickness, in white colour as
standard (other RAL colours on request). PVDF coating
has excellent corrosion resistance and resistance to
mechanical damage; the coating also provides long
term colour stability, even in temperature up to 120C.
PVC (F) lm of 120 m thickness, in white colour is a
special coating of increased hardness, to apply in food
industry construction works and cold stores. PVC (F)
lm is not susceptible to blurs, it is also easily washable
and resistant to most industrial cleaning agents.
On special order we also offer sandwich panels with fa-
cings made of stainless steel:
Corrosion resistant steel applied either on one or on
both sides of Ruukki wall panels SP2B PU and Ruukki
panels for cold-storage SP2E PU; panels with stain-
less steel facings are used in pharmaceutical and food
processing industry.
20
Sandwich panels for walls and roofs
Accessories Corrosion resistance Facings and coatings R250 R275 R500 R550
Sandwich panels for walls and roofs
Assembling during winter
Assemblig of panels which facing colours are in
III colour group [RAL 3013, 5005, 6011, 7016, 9007 &
RR 22, 23, 29, 34, 35, 36, 41] ought to be carried out
with min temperature 10C.
New span of ribbed profiling
In order to provide architects with additional
possibilities for creating interesting facades of
designed buildings we introduced new types of
ribbed proling dedicated to external cladding
of wall sandwich panels with mineral wool core.
For Ruukki SP2D W and SP2D WE panel we offer
ribbed proling with span of 250 mm and 500 mm.
For Ruukki SPB W and SPB WE - 1100 mm modular
width - we offer ribbed proling with span of 275
mm and 550 mm. For Ruukki SPB W and SPB WE -
1000 mm modular width - we offer ribbed proling
with span of 250 mm and 500 mm.
Features of ribbed profiling
Thickness of steel sheet used for external claddings
with new types of ribbed proling is 0.60 mm.
It allows to achieve more interesting architectural
effect and also to provide sandwich panels with the
best re resistance, thermal and acoustic insula-
tion parameters. Depth of ribbed proling is ~1 mm,
ensuring thus clearly visible proling result on
external cladding of facade panels.
Additional benefits
Sandwich panels with mineral wool core and new
types of ribbed proling are a good alternative
for expensive solutions based on aluminum cas-
settes. Sandwich panels guarantee short instal-
lation time, easy selection of supplementary
elements, accessories and colours, maintaining
at the same time high quality look of designed
facade.

Ribbed proling R250. Shopping center, Pila, Poland
21
For SP2D W and SP2D WE panels ribbed proling with span of
250 mm. Also available for SPB W panels with 1000 mm modular
width.
For SP2D W and SP2D WE panels ribbed proling with span
of 500 mm. Also available for SPB W panels with 1000 mm
modular width.
For SPB W and SPB WE panels with 1100 mm modular width
ribbed proling with span of 275 mm.
For SPB W and SPB WE panels with 1100 mm modular width
ribbed proling with span of 550 mm.
Details of ribbed profiling
~250
~
1
~500
~
1
~275
~
1
~550
~
1
22
Presented colours have a view character and may
differ in tone from the exact RAL colour.
RAL colours Prof iling pattern
L Linear
S Sinusoidal
F Flat
P Embossed
R Ribbed
M Microprofiled
1
8
~90
~52 ~52
~
1
~
1~28 (~250, ~275, ~500, ~550)
~16
9010
9002
9006
*
1015
5005
6011
7035
7016
9007
*
3013
*
Due to the complexity of technological processes, manu-
facturers of sheets with organic coatings do not guarantee
uniform colour tints in successive delivery lots. It refers
particularly to steel sheets in metallic colours RAL 9006
and RAL 9007.
Therefore, in order to avoid any problems related to tint
differences and to maintain uniform colour of panel facing,
Buyer should agree with Seller in writing, prior to the con-
clusion of sales agreement, which part of the order/agree-
ment will refer to deliveries for one structure.
Once it is agreed by parties, Seller is obliged to fulll
the order from one lot of input material. Otherwise Ruukki
Polska Sp. z o.o. bears no liability for possible differences
in colour tints.
In case of any questions please contact our Sales Depart-
ment.
23
C
P
L

0
2
1

E
N

/

0
5
.
2
0
1
3

/

A
r
t
&
P
r
i
n
t

S
p
.

z

o
.
o
.
Ruukki Polska Sp. z o.o., Infoline 801 11 33 11
Customer service +48 46 85 81 600, +48 46 85 81 647, www.ruukki.com
Copyright 2013 Rautaruukki Corporation. All rights reserved. Ruukki is a trademark of Rautaruukki Corporation.
Rautaruukki, Ruukki, Working. Living. Moving and Ruukki's product names are trademarks or registered trademarks of Rautaruukki Corporation.
Due to the ongoing product research and development works, Ruukki Polska Sp. z o.o. reserves the right to amend the content of this
catalogue without any prior notice. This publication does not constitute an offer as meant by the law.