This document summarizes guidelines for premises and facilities from Malaysia's GMP Element 1. It discusses considerations for layout design, construction materials, drainage, waste disposal, and toilet facilities. The key points are:
1) Plant layout design should consider traffic flow, potential for contamination, and efficiency. Straight-through, U-shaped, and L-shaped are the main options.
2) Construction materials must be approved for food production use and allow for easy cleaning. Floors should be non-absorbent and sealed concrete is often used.
3) Drainage systems must be designed to prevent cross-contamination and allow for cleaning. Waste should be contained and disposed of properly.
4
Original Description:
Presentation
Original Title
3. GMP Element 1 (MS1514_2009), The Confusion Among Consultants. (1)
This document summarizes guidelines for premises and facilities from Malaysia's GMP Element 1. It discusses considerations for layout design, construction materials, drainage, waste disposal, and toilet facilities. The key points are:
1) Plant layout design should consider traffic flow, potential for contamination, and efficiency. Straight-through, U-shaped, and L-shaped are the main options.
2) Construction materials must be approved for food production use and allow for easy cleaning. Floors should be non-absorbent and sealed concrete is often used.
3) Drainage systems must be designed to prevent cross-contamination and allow for cleaning. Waste should be contained and disposed of properly.
4
This document summarizes guidelines for premises and facilities from Malaysia's GMP Element 1. It discusses considerations for layout design, construction materials, drainage, waste disposal, and toilet facilities. The key points are:
1) Plant layout design should consider traffic flow, potential for contamination, and efficiency. Straight-through, U-shaped, and L-shaped are the main options.
2) Construction materials must be approved for food production use and allow for easy cleaning. Floors should be non-absorbent and sealed concrete is often used.
3) Drainage systems must be designed to prevent cross-contamination and allow for cleaning. Waste should be contained and disposed of properly.
4
The Confusion Among Consultants Lecturer: Dr. Maaruf Abd Ghani Members : Laila Liyana Mohd Noor (P68050) Nursheila Mustafa Muin (P67316)
Ministry of Healths GMP Guidelines Element 1-Premise and Facilities Element 2-Operation Control Procedures and Practices Element 3-Sanitation and Maintenance Element 4-Personnel Element 5-Transportation and Distribution Element 6-Traceability Element 7-Internal Audit Element 8-Training
Element 1- Premise and Facilities Sub-Element 1
Location Premises Design Construction & Structure walls, ceiling, floors, windows & doors State of repair Drainage and Waste Disposal Plant Layout Zonning clean, dry, wet, high care, etc. Movement of goods and people Facilities Toilets, Changing Rooms & Lockers Personnel Hygiene Stores Water Supply Lighting & Ventilation Machines & Equipment Made of, type and design
PREMISE Premise Design (layout)
There are 3 choices in overall plant layout that can cause confusion among Consultants: Straight-through U shaped L shaped
Design Layout Straight-through U shaped L shaped elongated or large area in between or smaller area for corner lot area shipping and receiving are at opposite ends of the building shipping and receiving on one side shipping and receiving are at different ends of the building relatively simple expansion expansion more complex simple expansion reduce the number of contamination increase labor productivity reduce the number of contamination Layout For the best layout, some of the expected benefits through the final designs are: safe working environment, reduce material handling cost, reduce number of lift-trucks needed, increase employees efficiency, and reduced waste
Construction & Structure The processing plants must be: constructed with approved materials and maintained under hygienic, sanitary conditions construction materials of the equipment, walls, floors, ceilings, doors, windows, and fixtures should be safe, non-toxic and meet approved standards for use in a food processing facility avoid accumulating dirt and can be easily cleaned and sanitized Materials of walls, floors, ceilings, doors and windows must be choose according to the: working area area size companys budget clean ability durability and safety Floor Type of floors that were usually used such as: tiles concrete epoxy sealed concrete polyurethane sealed concrete stainless steel floor and others Floor Tiles disadvantage: tiny space of each tile block - can cause dirt accumulation and difficult to clean many types of tiles floors with different color, shape, roughness and design
Tiny space Floor Uncoated Concrete was proven with low growth of bacteria on its surface the rough and porous nature makes it difficult to clean and remove attached bacteria for these reasons it is not suitable for use in food production facilities with strict hygiene requirements to overcome this problem: the concrete must be sealed with other material such as epoxy or polyurethane Floor Epoxy Polyurethane (PU) not recommended for outdoor use - cannot handle the constantly fluctuating state of outdoor concrete works well indoors and outdoors not so effective at reducing bacterial levels on surface effective at reducing bacterial levels on surfaces industrial grade epoxies are very oil and chemical resistant highly resistant to oil and most contaminants forms a very strong bond to concrete forms a weak bond when applied directly to concrete and usually used a topcoat with an epoxy based primer has been in use for 65 years has been in use for 20+ years Floor Epoxy Polyurethane (PU) Ceiling It is not good practice to use acoustic tile for the ceiling in a food plant. The hidden side of the ceiling tends to be come dirty and is a potential source of contamination.
In fact, it is not recommended to have any ceiling in a food plant, if possible. Good food plant design uses a precast roof structure in which case a ceiling is not needed. Ceiling The most recommended ceiling installation is the concrete slab
Floors, walls, ceilings, and doors in any area where food is handled or stored: should not absorb water should be easy to scrub keep clean the materials selected should not be susceptible to cracks, scars, or pitting when exposed to sanitizer and normal conditions of use must avoid dirt accumulation or entrap food particles- can lead to contamination of food products
The important features - joints between vertical elements (e.g., columns or walls) and floors should be coved (rounded) to prevent dirt accumulation This features is overlooked among few consultants it is not stated specifically in GMP guideline Columns should be encased in concrete with tapered tops If there is no cove, the areas where floors and walls meet need to have a waterproof seal to prevent water and food debris from accumulating in the area or behind the walls or under the floor
Drainage & Waste Disposal In a wet facility, the areas may contain water, grease, blood, fat, syrups and other materials on the floor Such areas typically must have hub or trench drains - handle large quantities of water, but difficult to clean and can harbor microbes Properly sloped floors should be constructed to avoid water reservoir that can cause contamination Removable grates or plugs on drains should be installed to protect against pests Drains should be regularly cleaned and sanitized
Drains in the processing area can be uncovered and it should be made with suitable materials Guideline standard: The drainage channels must in fully or partially open It need to be so designed as to ensure that waste does not flow from a contaminated area towards or into a clean area, in particular an area where foods likely to present a high risk to the final consumer are handled
Waste Disposal Ideally, waste, whether liquid or solid, should be stored in closed containers that are not next to open entries into the plant. waste containers and the areas around them must also be kept clean to eliminate food that can attract pests. these containers and the areas around them should also drain properly to eliminate water that can attract pests. Good Practice Bad Practice
TOILET A well-designed toilet has to be: Clean and dry Well ventilated Easy to maintain Carefully planned layout Handicap friendly Ventilation System Proper ventilation is one of the highest priorities
Ineffective ventilation can make a toilet unbearable, even if it is well designed
Effective ventilation ensures that vitiate air is quickly extracted and helps to avoid dampness and subsequent growth of mould on floor, wall and ceiling
The toilet air should be extracted to the outside by a mechanical ventilation system at a rate not less than 15 air charges per hour Ventilation System
There are generally two types of air flow configurations used in toilet:
Non-unidirectional Unidirectional Non-unidirectional air flow Unidirectional air flow Single pass air flow pattern
Also called 'laminar' air flow
Used where low air borne contaminant levels are required and where internal contaminants are the main concern
Contamination generated in the room is generally swept down and out Used in rooms where major contamination is expected from external source
Turbulent flow enhances the mixing of low and high particle concentrations, producing a homogenous particle concentration Where unisex facilities are provided, it shall:
Be located in a self contained compartment offering full privacy by way of full height doors and walls
Contain a water closet (WC) pan, basin, sanitary towel disposal equipment, but no urinal bowls
Be located so that access is not via an area restricted to one sex
Males facilities may include urinal bowls
Sanitary facilities for females shall have provision for sanitary towel disposal equipment
Where separate facilities are provided, it shall: Toilet Layout Various screening arrangements for toilets showing the visibility from external area Doors have been replaced by offset entrance maze which blocks the view yet allows easier, hands-free access Off-set entrance maze without doors Toilet Layout Single entrance/exit plans provide the path of personnel, not cross each other
Dispensing the entrance door helps to: improve the ventilation minimizes hand contact for hygiene reasons
Highly resistant to water beading and bacterial buildup
Very hard to scratch, chip, dent or gouge it with pens or pocket knives
If it is spray painted, it is very easy to wipe them clean without any traces of color remaining
Solid Plastic
Economical
Resistant to damages from scratches and dents
Water resistant
Bacterial growth is minimized Toilet Partition/Divider Stainless Steel
Rust proof
Never use anything acidic because it will permanently damage the steel
Expensive, but well worth the money if the factory has the budget
Baked Enamel
Most sensitive material
Must be cleaned with mild soap solutions, lukewarm water and a soft cloth
Chemical cleaners and particularly strong detergents should be avoided
Male Toilet The access entrance to male toilets should not open directly to the urinal area
Avoid entrances opening onto a wall surface with the mirror reflecting the urinals
As to keep the urinal areas dry, stainless steel grating could be installed over the drainage and below the urinal bowls Wash Basin Electronically controlled taps should be considered. Sensor controlled taps with their precise flow settings and positive shutoff characteristics, providing adequate water flow when it is required
Further to this, it will minimize hand contact and as an effort to conserve water
Liquid soap dispensers, sanitizers, paper towel dispenser or hand dryer and bins should be installed adjacent to the wash basins
Personnel Facilities Changing room Lockers Reasons for the confusion among Consultants Education Training Experience THANK YOU