You are on page 1of 1

375-2013:QuarkCatalogTempNew 8/9/13 9:59 AM Page 375

Overload Relays
 Screw Terminals
 Trip Type Class 5, 10, 20 and 30 Adjustable
 Overload Protection, Phase Failure Protection
and Unbalance Protection
 Internal Ground-Fault Detection
(Requires Activation)








Internal Power Supply


Auxiliary Contacts 1 NO + 1 NC
Manual and Automatic RESET
Electrical Remote RESET Integrated
Switch Position Indicators
TEST Function and Self-Monitoring

The 3RU11/3RU21 thermal overload relays are designed for the protection of three-phase and single-phase AC and DC
motors. If single-phase AC or DC loads are to be protected using 3RU11/3RU21 thermal overload relays, all three bimetal
strips should be heated. Therefore all main circuits must be connected in series.





SIRIUS 3RB31 Solid-State Overload Relays


The 3RB31 solid-state overload relays up to 40 A with internal power
supply have been designed for inverse-time delayed protection of loads
with normal and heavy starting against excessive temperature rises due
to overload, phase unbalance or phase failure.

 TEST Function
 STOP Button
 Class 10

Screw Terminals
Auxiliary Contacts: 1 NO + 1 NC
Manual/Automatic RESET
Switching Position Indication

The 3RB31 solid-state overload relays are suitable for customers from
all industries who want to guarantee optimum inverse-time delayed
protection of their electrical loads (e.g. motors) under normal and heavy
starting conditions (CLASS 5 to CLASS 30 selectable), minimize project
completion times, inventories and power consumption, and optimize
plant availability and maintenance management.

ENCLOSURES

SIRIUS 3RU21 Thermal Overload Relays

MOTOR CONTROLS,
DRIVES & CONTACTORS

Thermal Overload Relays

Solid-State Overload Relays

The 3RU21 thermal overload relays up to 40 A have been


designed for current-dependant protection of loads with normal
starting against excessive temperature rises due to overload or
phase failure.

 With Suitable Terminal Brackets, These Overload Relays Can Also


Be Installed as Stand-Alone Units
Amps

Contactor
Size

EACH

70240124
70240130
70240122
70240127
70240123
70240128
70240125
70240131
70240126
70240129
70240132

3RB31134RB0
3RB31234RB0
3RB31134NB0
3RB31234NB0
3RB31134PB0
3RB31234PB0
3RB31134SB0
3RB31234SB0
3RB31134TB0
3RB31234QB0
3RB31234VB0

0.10-0.40
0.10-0.40
0.32-1.25
0.32-1.25
1.00-4.00
1.00-4.00
3.00-12.00
3.00-12.00
4.00-16.00
6.00-25.00
10.00-40.00

S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S0

152.80
164.33
152.80
164.33
152.80
164.33
152.80
164.33
152.80
164.33
203.43

 Trip Type Class 10


 Overload and Phase Failure Protection

SIRIUS 3RB21 Solid-State Overload Relays

3RB2153-4FW2

Mfr.s
Type

Amps

Contactor
Size

EACH

70240106
70240107
70240109
70240108
70240120
70240121

3RB2133-4QB01
3RB2133-4UB01
3RB2143-4UB01
3RB2143-4EB01
3RB2153-4FC223
3RB2153-4FW224

6.0-25
12.5-50
12.5-50
25.0-100
50.0-200
50.0-200

S2
S2
S3
S3
S6
S6

181.21
243.40
405.66
405.66
279.81
291.45

Contactor
Size

EACH

70240147
70240148
70240149
70240150
70240151
70240152
70240153
70240154
70240155
70240156
70240157
70240158
70240159
70240168
70240160
70240169
70240161
70240170
70240162
70240171
70240163
70240172
70240164
70240173
70240165
70240174
70240166
70240175
70240167
70240176
70240177
70240178
70240179
70240182
70240180
70240181
70240183

3RU21160AB0
3RU21160BB0
3RU21160CB0
3RU21160DB0
3RU21160EB0
3RU21160FB0
3RU21160GB0
3RU21160HB0
3RU21160JB0
3RU21160KB0
3RU21161AB0
3RU21161BB0
3RU21161CB0
3RU21261CB0
3RU21161DB0
3RU21261DB0
3RU21161EB0
3RU21261EB0
3RU21161FB0
3RU21261FB0
3RU21161GB0
3RU21261GB0
3RU21161HB0
3RU21261HB0
3RU21161JB0
3RU21261JB0
3RU21161KB0
3RU21261KB0
3RU21164AB0
3RU21264AB0
3RU21264BB0
3RU21264CB0
3RU21264DB0
3RU21264NB0
3RU21264EB0
3RU21264FB0
3RU21264PB0

0.11-0.16
0.14-0.20
0.18-0.25
0.22-0.32
0.28-0.40
0.35-0.50
0.45-0.63
0.55-0.80
0.70-1.00
0.90-1.25
1.10-1.60
1.40-2.00
1.80-2.50
1.80-2.50
2.20-3.20
2.20-3.20
2.80-4.00
2.80-4.00
3.50-5.00
3.50-5.00
4.50-6.30
4.50-6.30
5.50-8.00
5.50-8.00
7.00-10.00
7.00-10.00
9.00-12.50
9.00-12.50
11.00-16.00
11.00-16.00
14.00-20.00
17.00-22.00
20.00-25.00
23.00-28.00
27.00-32.00
34.00-40.00
30.00-36.00

S00
S00
S00
S00
S00
S00
S00
S00
S00
S00
S00
S00
S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S00
S0
S0
S0
S0
S0
S0
S0
S0

44.43
44.43
44.43
44.44
44.43
44.43
44.43
44.43
44.43
44.43
44.43
44.43
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
44.43
62.88
62.88
62.88
62.88
97.47
97.47
97.47
97.47

OPTOELECTRONICS

Stock
No.

Amps

SIRIUS 3RU11 Thermal Overload Relays

1Direct mounting with matching terminal blocks. 2Direct mounting with stand-alone installation. 3S6 with busbar connections.
4Equipped

with straight through transformer.


The 3RU11 thermal overload relays up to 100 A are designed for
current-dependent protection of applications with normal start-up
conditions against impermissibly high rises in temperature as a
result of overload or phase failure.

Overload Relay Accessories

Stock
No.

Mfr.s
Type

For Use With


Overload Relays

Size

EACH

70240146
70240184
70240185

3RU1936-3AA01
3RU29163AA01
3RU29263AA01

3RU11
3RU21, 3RB30, 3RB31
3RU21, 3RB30, 3RB31

S2
S00
S0

17.75
12.35
14.53

Stock
No.

Mfr.s
Type

Amps

Contactor
Size

For Use
With
Contactors

EACH

70240133
70240134
70240139
70240135
70240140
70240136
70240141
70240137
70240138
70240142
70240143
70240144
70240145

3RU1136-4BB0
3RU1136-4DB0
3RU1146-4DB0
3RU1136-4EB0
3RU1146-4EB0
3RU1136-4FB0
3RU1146-4FB0
3RU1136-4GB0
3RU1136-4HB0
3RU1146-4JB0
3RU1146-4KB0
3RU1146-4LB0
3RU1146-4MB0

14-20
18-25
18-25
22-32
22-32
28-40
28-40
36-45
40-50
45-63
57-75
70-90
80-100

S2
S2
S3
S2
S3
S2
S3
S2
S2
S3
S3
S3
S3

3RT103
3RT103
3RT104
3RT103
3RT104
3RT103
3RT104
3RT103
3RT103
3RT104
3RT104
3RT104
3RT104

63.46
63.46
91.30
79.02
91.30
79.02
91.30
87.43
87.43
99.67
111.23
125.38
159.47

MOTOR CONTROLS, DRIVES & CONTACTORS 375

INDEX

 Terminal Brackets for Stand-Alone Installation of Overload Relays with Screw Terminals
 For Separate Mounting of the Overload Relays; Screw and Snap-On Mounting onto TH 35 Standard Mounting Rail

Phase Failure Sensitivity


Integrated, Sealable Cover
4-10 Seconds Tripping Time for Class 10
Can Be Panel Mounted Using the Appropriate Adapters

ASSEMBLY






PASSIVE & ACTIVE

The 3RB21 solid-state overload relays have been designed for the protection of induction motors in sinusoidal 50/60 Hz
voltage networks. The relays are not suitable for the protection of single-phase AC or DC loads.

Mfr.s
Type

TEST & MEASUREMENTS

3RB2133-4UB0

The 3RB21 solid-state overload relays are suitable for customers from all industries who want to guarantee optimum inversetime delayed protection of their electrical loads (e.g. motors) under normal and heavy duty conditions, minimize project
completion times, inventories and power consumption, and optimize plant availability and maintenance management.

Stock
No.

INTERCONNECT

Mfr.s
Type

POWER

Stock
No.

You might also like