You are on page 1of 3

ELASTOPOR BOARD

Technical Data Sheet


BASF Polyurethanes (India) Limited
12, TTC Industrial Area, Thane Belapur Road, Opp. Turbhe Station, Navi Mumbai.
Tel.: +91 22 6791 7271, FAX No.: +91 22 6712 7628
Page 1 of 3



Version: 00
Edition: 08/2009



Description
Board with High performance PUR Insulation core, compounded with aluminum/paper as the
face and rear plate.PUR Insulation manufactured without the use of CFC which can be bonded
to the existing deck/vapor layer or mechanically fixed.
Application
Thermal Insulation of
1) Flat Roofs
2) Flat Metal decks
3) Pitched Roofs
4) Green Roofs
5) Balconies and Terraces




ELASTOPOR BOARD
Technical Data Sheet
BASF Polyurethanes (India) Limited
12, TTC Industrial Area, Thane Belapur Road, Opp. Turbhe Station, Navi Mumbai.
Tel.: +91 22 6791 7271, FAX No.: +91 22 6712 7628
Page 2 of 3



Advantages:
1) Highest in Insulation performance.
2) Water resistant
3) CFC Free
4) Complies to B3 Fire Rating (according to DIN Standard 4102-1)

Physical Properties of Foam Core

Property Standard Unit Value
Overall density DIN EN ISO 845 kg/m 45
Thermal
Conducttivity
Hesto W/Km2 0.025
Compressive
strength
DIN 54321 Kpa 260
Flexural Strength DIN 54323 Kpa 560
Bending DIN 54323 mm 10
Fire Classification DIN 4102 B3
Dimensional
Stability
DIN 53431 %
Max 0.1%
Max 0.2%
Appearance
Surface
Edge Profile

Skin
Flat
Dimensions
Width
Length
Thickness

As per your
requirement
Closed cell
content
ISO 4590 >95
Water absorbstion DIN 53428 Vol. -% <1%

ELASTOPOR BOARD
Technical Data Sheet
BASF Polyurethanes (India) Limited
12, TTC Industrial Area, Thane Belapur Road, Opp. Turbhe Station, Navi Mumbai.
Tel.: +91 22 6791 7271, FAX No.: +91 22 6712 7628
Page 3 of 3





Installation:
The Board shall be laid over a non-bituminous vapor control layer (if required).Boards should be
laid with edges butted and in a break bonded pattern laid at right angles to the edges of the roof
or diagonally across the roof.
Ensure that all joints are supported by the deck. The boards are normally secured using
mechanical fasteners with appropriate stress plate to the substrate. In case the boards are
overlaid with cement-screed or tile or green roof built-up, mechanical fastening is not necessary
can be loosely laid and secured temporarily using loose ballast. Please consult BASF
Representative for project specific method statement.
Sizes
PUR Boards are available in 1 m x 1 m x Req.Thickness

Operational Conditions:
PUR Boards are suitable for range of continuous temperatures within 40C to 70C
Long exposure to temperatures higher than the above mentioned range may cause deformation
of foam & facing materials, but will not cause melting.

Storage:
Keep them in a cool, dry place away from moisture and direct sunlight.Keep them in original
secondary packing to avoid any physical damage.
.
Waste Disposal
Disposing of waste should not be in conflict with national or international regulations. Therefore,
check with your local authorities on how to treat both raw material and production waste.

You might also like