SIMATIC FS fail-safe sensors ensure safe and reliable protection for people, machines, and plants. Save costs by integrating safety technology Safety Integrated is the consistent implementation of safety technology functions directly into our standard products.
SIMATIC FS fail-safe sensors ensure safe and reliable protection for people, machines, and plants. Save costs by integrating safety technology Safety Integrated is the consistent implementation of safety technology functions directly into our standard products.
SIMATIC FS fail-safe sensors ensure safe and reliable protection for people, machines, and plants. Save costs by integrating safety technology Safety Integrated is the consistent implementation of safety technology functions directly into our standard products.
of humans and machines Brochure April 2009 SIMATIC Sensors Answers for industry. BR_Titelseite_EN_Neu.fm Seite 1 Mittwoch, 1. April 2009 5:24 17 Siemens AG 2009 SIMATIC FS fail-safe sensors 2 SIMATIC FS fail-safe sensors For all-round protection of people and machines For the protection of persons and machines in the industrial environment, maximum process reliability is paramount. Not simply to prevent adverse events, but also to achieve the greatest possible plant availability for maximum efficiency. A clear case for SIMATIC FS fail-safe sensors. They ensure safe and reliable protection for people, machines, and plants. Fail-safe sensors are an important component of Safety Integrated. Save costs by integrating safety technology Safety Integrated is the consistent implementation of safety technology in terms of Totally Integrated Automation. That means we integrate safety technology functions directly into our standard products and offer consistent and user-friendly integration in standard automation. This provides numerous advantages for machine manufacturers and plant operators, particularly in economic terms. Fail-safe sensors Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Switching strips SIMATIC FS100 for reliable and flexible protection of pinch points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Light barriers SIMATIC FS200 for compact access protection . . . . . . . . . . . . . . . . . . 9 Light curtains, light grids and transceivers SIMATIC FS400 for flexible danger zone protection . . . . . . . . . . . . . . 11 Laser scanners SIMATIC FS600 An all-round view for safety . . . . . . . . . . . . . . . . . . . 19 All you need to know about fail-safe sensors Information, training, ordering . . . . . . . . . . . . . . . . . 22 Broad product range Laser scanners, light curtains/grids and light barriers for contact-free detection in danger areas International designs (e.g. UL/CSA) for applications all over the world All-round protection of people and machinery/ plants in stationary and mobile applications Maximum availability thanks to wear-free and maintenance-free technology Machine concepts possible without mechanical safety systems and safety fences Component of Totally Integrated Automation and Safety Integrated BR_Sicherheitssensoren_Eng.fm Seite 2 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS fail-safe sensors 3 Portfolio overview SIMATIC FS100 switching strips Pinch points are a danger on many machines and other technical installations. In these situations, the simplest protection is implemented with rubber switching strips that on the one hand halt the dangerous motion in a fail-safe state and on the other hand act as a buffer to prevent injury. The edge of the rubber strip (signal transmitter) is monitored optically by means of a fail-safe sending/receiving sensor that is inserted into the strip from the outside. This means that any length can be used, cut to length as required by the customer. SIMATIC FS200 light barriers When space is at a premium, contact-free light barriers are the ideal solution for access protection to danger zones, danger points, or entry points. Designed with IP65/IP69K degree of protection, in type 2 they have a range of up to 40 m according to IEC/EN 61496. The light barriers of type 4 according to IEC/EN 61496 with up to 60 m range feature frequency-modulated IR and integrated accumulated dirt monitoring. Additional evaluation units support start/restart inhibiting or contactor control. SIMATIC FS400 light curtains, light grids and transceivers The electro-sensitive and active optoelectronic light curtains and grids for SIL 2 and 3 ac- cording to IEC 61508, PL d and e according to ISO 13849-1, or types 2 and 4 according to IEC/EN 61496 protect operating personnel working on or near running machines and systems. Thanks to specially developed integrated circuits (ASICs) and a patented, intel- ligent evaluation technique, they are extremely fault-tolerant and highly available. A wide range of different functions, including start/restart inhibiting, contactor control, muting, cycle control and blanking, support a wide range of different applications such as finger and hand protection, horizontal danger zone protection, or access protec- tion for large areas. Versions for communication with ASIsafe and PROFIsafe are avail- able. SIMATIC FS600 laser scanners Laser scanners are optical distance sensors for the flexible protection of danger zones when used horizontally, or for providing access protection and motion monitoring when used vertically. They offer perfect all-round protection up to cate- gory 3 according to EN 954-1, SIL 2 according to IEC 61508, and PL d according to ISO 13849-1. With an operating angle of 190 and over a distance of up to 6.25 m, the laser scanner reliably detects any persons and objects. With up to eight programmable protective field pairs that can be selected during operation, our laser scanners can be optimally adapted to any application on machines, production robots, conveyor systems, or vehicles. BR_Sicherheitssensoren_Eng.fm Seite 3 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS fail-safe sensors 4 SIMATIC FS fail-safe sensors for a wide variety of applications Our broad range of laser scanners, light barriers, light curtains and light grids for contact-free securing of danger zones en- sures complete protection of people and machinery even worldwide thanks to international certifications, both in stationary and in mobile applications. Integrated functionality for evaluation and further processing saves time, external evaluation units, and wiring overhead. Find the right fail-safe sensor for your application. Application Crushing/ trapping protection on edges Single-beam access protection, edge protection Securing hazardous areas Access protection
Access protection for large areas Horizontal securing of hazardous areas near floor level Switching strips from page 7
Light barriers from page 9
Light grids from page 11
Light curtains from page 11
Transceivers from page 11
Laser scanners from page 19
BR_Sicherheitssensoren_Eng.fm Seite 4 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS fail-safe sensors 5 SIMATIC FS fail-safe sensors Horizontal danger zone protection Horizontal danger zone protection with several protective fields Collision protection for shifting units Traverse path monitoring for automated guided vehicle systems Access through passage control Application Switching strips from page 7 Light barriers from page 9 Light grids from page 11 Light curtains from page 11 Transceivers from page 11
Laser scanners from page 19 BR_Sicherheitssensoren_Eng.fm Seite 5 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS fail-safe sensors 6 Overview of safety categories and standards Machine manufacturers and operators are required by law to ensure the safety of people and the environment. As your partner, we offer support not only with the relevant safety-oriented products and systems, but always with up-to-date knowledge of international standards and regulations. The EN ISO 13849-1 standard EN ISO 13849-1 "Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design" is based on the familiar categories in EN 954-1:1996. It considers the complete safety functions with all devices in- volved in their implementation. With EN ISO 13849-1, safety functions are also investigated from a quantitative perspective going beyond the qualitative basis of EN 954-1. Performance levels (PL) are used, for this purpose, based on the various cat- egories. It may be applied to safety-related parts of control systems (SRP/CS) and all types of machines, regardless of the technology and energy used - electrical, hydraulic, pneumatic, mechanical, etc. The EN 62061 standard The standard EN 62061 "Safety of machinery Functional safety of electrical, electronic and programmable machine control systems" considers for the first time the total safety chain, from sensor to actuator. In order to reach a safety integrity level such as SIL 3, it is no longer enough that the individual components have the rele- vant certification. Instead, the entire safety function must be matched to the defined requirements. Demands on the per- formance of non-electrical safety-related control elements for machines such as hydraulic, pneumatic, or electro-mechan- ical elements are not defined in the standard. You can find more information on the relevant safety standards here: www.siemens.com/safety-integrated EN 954-1: 1996 Safety of machinery Safety-related parts of control systems Part 1: General principles for design EN ISO 13849-1: 2006 Safety of machinery Safety-related parts of control systems Part 1: General principles for design Influence Regardless of the application IEC 61508: 1998/2000 Functional safety of electrical, electronic and programmable machine control systems EN 62061: 2005 Safety of machinery Functional safety of electrical, electronic and programmable machine control systems Time IEC 62061: 2005 identical with EN 62061: 2005 EN ISO 13849-1: 2006 IEC 61508: 1998/2000 EN 954-1: 1996 BR_Sicherheitssensoren_Eng.fm Seite 6 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS100 switching strips 7 SIMATIC FS100 switching strips for reliable and flexible protection from pinch points Pinch points and cutting edges represent a safety risk on many machines and technical equipment. In these situa- tions, the simplest protection is implemented with rubber switching strips that on the one hand halt the dangerous motion in a fail-safe state and on the other hand act as a buffer to prevent injury. The switching strips are characterized by simple configura- tion, high performance, and easy installation. For rapid on- site installation, the switching strips are simply cut and mounted without glue. Together with the evaluation unit, they form a safety system approved according to IEC/EN 61496 1) up to type 4. Function principle The rubber strip (signal transmitter) is monitored optically by means of a fail-safe sending/receiving sensor that is inserted into the strip from the outside. This means that any length can be used, cut to length as required by the customer (max. 10 m). The IR light beam passes through the strip. If it is altered or interrupted, this will cause shutdown. Due to the reflective inner surface, the rubber profile can be bent to a certain extent. Shutdown can be actuated from above or from the side. The evaluation units in the 22.5 mm enclosure are suitable for fail-safe monitoring in control circuits up to type 4 according to IEC/EN 61496 1) . Two relay safety outputs and an HL signal- ing contact are available. The unit can be operated with auto- matic or manual restart. Application examples Edge protection on: Protective covers of machines Automated guided vehicle systems Lifting tables Lifting platforms Doors and gates 1) PL assignment according to EN ISO 13849 in preparation. Even slight pressure causes a change in the IR signal in the rubber profile and triggers the STOP signal. Advantages at a glance Flexible in use Contact-free, optical monitoring Up to 10 m length Approved with the corresponding evaluation unit for Category 4 according to EN 954-1 1)
Insensitive to extraneous light Suitable for difficult ambient conditions No adjustment required BR_Sicherheitssensoren_Eng.fm Seite 7 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS100 switching strips 8 Technology overview Find the right product faster with the product selection code! There is more information on the use of the product selection code on page 22. 1) PL assignment according to EN ISO 13849 in preparation. Switching strip Material, rubber profile EPDM, 70+/-5 Shore A Dimensions, rubber profile (W x H) = 25 mm x 330 mm Temperature resistance of rubber profile -50 to +120C (short-term) -30 to +100C (long-term) Resistance of rubber profile Ozone, conditionally oils, acids, solvents, fuels Product selection code 3RG7855 Evaluation unit Operating voltage 24 V DC (+20%/-10%) Intrinsic consumption < 4 W Output contacts 2NO (safety-related)/ 1NC (transistor,ing to N po- tential) Response time approx. 32 ms Ambient temperature -25 to +85 C Continuous current 4 A Max. switching current 4 A Max. operational voltage 250 V AC, 50/60 Hz Mechanical service life 30 million switching cycles Max. AC switching capacity 1000 VA Function indication Power: Green LED Channel: Green LED Supply voltage fuse protection 1 A, time-lag Overvoltage category 3 (4 kV) according to DIN VDE 01 10 Enclosure fixing Snap-on mounting on 35 mm DIN rail according to DIN EN 50022 Mounting position Any Degree of protection Snap-on enclosure IP20 according to DIN VDE 0440 Approvals Cat. 4 according to EN 954-1 1) Product selection code 3RG7857 BR_Sicherheitssensoren_Eng.fm Seite 8 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS200 light barriers 9 SIMATIC FS200 light barriers for compact access protection Light barriers are electro-sensitive protective devices for guarding access to danger zones, hazardous locations, and entry points. They are the optimum solution in most cases, especially when safety has to be assured without adversely affecting produc- tivity or causing a hindrance. Function Each interruption of a light beam triggers a signal for reliable interruption of a dangerous movement of a machine, plant or other motorized installation. A complete system comprises at least one thru-beam sensor with a separate emitter and receiver. There are three systems available: for type 2 according to IEC/EN 61496 with a range of 0.5 to 20 m or 0.5 to 40 m for type 4 according to IEC/EN 61496 with a range of 0 to 60 m Application examples Light barriers are especially suitable as access protection in: Motorized windows, doors, and gates Warehouse installations and devices Packaging machinery Palletizing machines Stacking machines Winding and unwinding machines Textile machines Food processing machines Printing and paper processing machines Processing machines of the chemicals, plastics, and rubber industry Circulating paternosters Lifting platforms Meat processing machines Light barriers for type 2 and type 4 Advantages at a glance Light barriers for type 2 according to IEC/EN 61496 Range: 0.5 to 20 m, 0.5 to 40 m IP67/IP69K degree of protection Connection through an M12 plug-in connector Light barriers for type 4 according to IEC/EN 61496 Range: 0 to 60 m Degree of protection IP65 Frequency-modulated infrared light Integrated accumulated dirt monitoring using a LED Integrated heating of the optical system High mechanical and chemical resistance due to glass optics BR_Sicherheitssensoren_Eng.fm Seite 9 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS200 light barriers 10 Technology overview 1) Typical operating range limit: max. operating range without surplus light emission. Find the right product faster with the product selection code! There is more information on the use of the product selection code on page 22. Light barriers Type according to IEC/EN 61496 Type 2 Type 4 Operating voltage 10 V to 30 V DC 24 V DC Response time 5 ms max 20 ms Operating range 0 to20 m, 0 to 40 m 0 to 60 m Typical operating range limit 1) 0 to 22 m, 0 to 44 m
Operating temperature -30 to +55 C -25 to +60 C
Degree of protection IP67/IP69K IP65 Connection M12 circular connector Heavy-gauge threaded joint Product selection code 3RG7823 3RG7824 Benefits at a glance Evaluation unit for type 2 Start and restart inhibit Contactor control Floating safety outputs Separate signaling outputs as pnp transistor outputs Permanent cyclic testing The operating function is not interrupted when testing Up to 6 light barrier pairs can be connected in series Evaluation unit Type according to IEC/EN 61496 Type 2 Operating voltage 24 V DC, 15% Response time max. 20 ms Current consumption approx. 200 mA Safety output 2 floating NO contacts Loading capacity max. 4 A Signaling outputs Separate pnp transistor outputs Operating temperature -25 to +60 C Degree of protection IP40 Product selection code 3RG7825 BR_Sicherheitssensoren_Eng.fm Seite 10 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 11 SIMATIC FS400 light curtains, light grids and transceivers for flexible protection of hazardous areas The electro-sensitive and active optoelectronic light curtains, light grids, and transceivers for type 2 and type 4 according to IEC/EN 61496 or SIL 2 and 3 according to IEC 61508, PL d and e according to ISO 13849-1 protect operating person- nel working on or near running machines and systems. Thanks to specially developed integrated circuits (ASICs) and a patented, intelligent evaluation technique, they are extremely fault-tolerant and highly available. A wide range of different functions including start/restart inhibiting, contactor control, muting, cycle control and blanking support a wide range of different applications such as finger and hand protection, hor- izontal danger zone protection or access protection for large areas. Function principle A light curtain or light grid comprises an emitter and a receiver which must be mounted opposite each other. Depending on the resolution and the length, a certain number of transmit and receive diodes are arranged on top of each other. The infrared LEDs of the emitter emit short light pulses that are detected by the receive diodes. Connection versions The light curtains, light grids and transceivers are available in the following connection versions: Transistor outputs with - M12 connection - Cable gland - Hirschmann connection - Brad Harrison connection (MIN series for NAFTA) Relay output with - Hirschmann connection Bus versions - AS-Interface with ASIsafe profile - PROFIBUS with PROFIsafe profile Application areas Horizontal and vertical hazardous location and danger zone protection Access protection Pass-through control SIMATIC FS420 PROFIBUS/PROFIsafe light curtains Benefits at a glance Especially resistant to interference, and high availability due to application-specific integrated circuits (ASICs) and intelligent evaluation techniques Various resolutions and protective field heights Various function packages (standard, blanking, mut- ing, sequence control) Various connection options Can be used for various safety categories BR_Sicherheitssensoren_Eng.fm Seite 11 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 12 Overview of SIMATIC FS400 light curtains, light grids and transceivers Find the right product faster with the product selection code! There is more information on the use of the product selection code on page 22. Standard Erweitert Premium Design 3RG78 46 3RG78 43 3RG78 41 3RG78 45 3SF78 42 3RG78 44 3SF78 44-6 3SF78 44-8 Integrated evaluation unit
Standard functions
Blanking
Muting
Sequence control
Local interface
Transistor output
Relay output
M12 connection
Cable gland
Hirschmann connection
Brad Harrison connection
ASIsafe
PROFIsafe
EN 954-1 Cat. 4 Cat. 2 Cat. 2 Cat. 4 Cat. 4 Cat. 4 Cat. 4 Cat. 4 IEC/EN 61496-1, -2 Type 4 Type 2 Type 2 Type 4 Type 4 Type 4 Type 4 Type 4 EN/ISO 13849-1 PL e PL d PL e PL e PL e PL e PL e EN/IEC 61508 SIL 3 SIL 2 SIL 3 SIL 3 SIL 3 SIL 3 SIL 3 Selection code 3RG78 46 3RG78 43 3RG78 41 3RG78 45 3SF78 42 3RG78 44 3SF78 44-6 3SF78 44-8 BR_Sicherheitssensoren_Eng.fm Seite 12 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 13 Functionality Standard and sequence control Contactor control The contactor control monitors the contactors, relays, or valves connected downstream of the light curtain. Contact blocks with positive action contacts are required. Start/restart inhibit To prevent the system from immediately restarting when the protective zone is clear following a trigger, the start/reset in- hibitor can be activated. The use of the start/reset inhibitor is required for access protection, because only the entry to the danger zone is monitored but not the area between the pro- tective zone and the dangerous motion. Sequence control If it is necessary to enter the light curtain's protective field once or twice (e.g. to place or remove workpieces), the se- quence control function should be selected. This functionality is primarily required in presses. Increased resistance to strong extraneous light (Multi-Scan) If strong interference is expected due to extraneous light in harsh environments, for example due to welding robots or strobe lamps, when the beam is interrupted it is often simpler to first wait to see if the disruption continues before the out- puts are switched off. The availability of the system is thus increased, but the re- sponse time and thus the safety clearance are also increased. SafetyLab diagnostics and parameterization software Alternatively, with the optional SafetyLab diagnostics and pa- rameterization software, the functions of the light curtains, light grids, and transceivers can easily be set for type 4 in ac- cordance with IEC/EN 61496 using the PC. SafetyLab can be used for devices of the function packages blanking, muting and sequence control. SafetyLab automatically recognizes the function package and displays only the settings available to it Definition of 1-channel and 2-channel contact safety circuits Different status signals can be assigned to status signal outputs Modification of the display content of the 2x7-segment display Linking of beam areas with internal signals, etc. BR_Sicherheitssensoren_Eng.fm Seite 13 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 14 SIMATIC FS400 light curtains Functionality blanking If there are objects permanently in the area of the light curtain, these may be hidden using the blanking functions so that trouble-free operation is ensured. A distinction is made between objects in a fixed location which are per- manently located in the protective zone, and moving objects which can temporarily leave the protective zone. Configuration is implemented by means of the teach-in function, the DIP switch, the safety keys, or the SafetyLab diagnostics and parameterization software. Fixed blanking If an object is permanently located in the light path, the corresponding zone can be suppressed. This is achieved by suppressing the required number of beams. The object must be permanently located in the area of the hidden beams. If this is not the case, the light curtain switches the system off, because otherwise safety can no longer can be ensured. . Floating blanking If moving objects are located in the light path, any number of beams can be suppressed. The objects can move within the suppressed beams without the light curtain switching off. If the moving objects are removed from the zone, the light curtain will interrupt the hazardous movement, otherwise safety can no longer be guaranteed. Reduced resolution If an object is located in the light path, two or three beams can be suppressed. The difference between reduced resolution and floating blanking is that continuous monitoring does not take place. The "reduced resolution" function changes the effective resolution of the light curtain. The safety clearance must be recalculated for the new resolution. BR_Sicherheitssensoren_Eng.fm Seite 14 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 15 SIMATIC FS400 light curtains, light grids and transceivers Functionality muting When arranged vertically, light curtains, light grids and transceivers are often used for protecting access points. With additional sensor signals, the protective function can be suppressed to allow material to be transported in or out of danger zones, for example. The protective field is temporarily suppressed and, once the goods have passed through, reactivated. Muting restart If the power fails while goods are passing the muting sensors, for example, the valid muting sequence is interrupted. When the power supply has been restored, muting is not automati- cally resumed because the muting sequence is not as expect- ed. To remove the goods from the area covered by the muting sensors, an integrated retraction mode can be activat- ed using the start key. 4-sensor sequential muting If the material that is to be transported into the danger zone always has the same dimensions and there is no lack of space, sequential muting is preferred. With sequential muting, four muting sensors are connected. These must be activated in a predefined sequence to trigger muting. All four sensors must be activated simultaneously for a short time. 2-sensor parallel muting Parallel muting is ideal in plants in which the dimensions of the transported goods are not constant or space requirements must be kept to a minimum. This procedure is also used when transport it to take place in both directions. In addition, two muting sensors are arranged such that their beams cross behind the protective field in the danger zone. 3-sensor direction muting 3-sensor direction muting is configured in a similar way to 2-sensor parallel muting. Material can only be transported through the light curtain in one direction. To trigger the muting function, muting sensor M1 must first be activated, followed by muting sensors M2 and M3. If the paths for muting sensors M2 and M3 are interrupted, sensor M1 does not need to be activated. 4-sensor parallel muting If the transported material is too small to be simultaneously recognized by 4 sequentially arranged sensors, and the applica- tion offers no space to create the light barriers cross for 2-sensor parallel muting, 4-sensor parallel muting, e.g. using light scanners, is a possibility. The function of 4-sensor parallel muting corresponds to that of 2-sensor parallel muting. However, the activation signal is obtained from two sensor pairs. BR_Sicherheitssensoren_Eng.fm Seite 15 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 16 Technology overview 1) including standard functions SIMATIC FS400 light curtains Product selection code Protective field height (mm) Resolution (mm) Standard Blanking 1) Muting 1) Sequence control 1) External evaluation 1) 3RG78 46 300 ... 1800 14 150 ... 1800 20/30/40 600 ... 1800 90 3RG78 43 150 ... 1800 20/30/40 450 ... 1800 90 3RG78 41 150 ... 1800 30 300 ... 1800 55 450 ... 1800 80 3RG78 45 150 ... 1800 14/30 450 ... 3000 50 750 ... 3000 90 3SF78 42 150 ... 1800 14/30 450 ... 3000 50 750 ... 3000 90 3RG78 44 150 ... 1800 14/30 14/30 14/30 450 ... 3000 50 50 50 3SF78 44 300 ... 1800 14/30 14/30 14/30 SIMATIC FS400 light grids and transceivers Product selection code Number of beams Beam spacing (mm) Range (m) Standard Muting 1) External evaluation 1) 3RG78 45 4/3/2 300/400/500 0,8 ... 18 4/3/2 300/400/500 6 ... 60 2 500 6,5 3SF78 42 4/3/2 300/400/500 0,8 ... 18 4 300 6 ... 60 2 500 6,5 3RG78 44 4/3/2 300/400/500 0,8 ... 18 4/3/2 300/400/500 6 ... 60 2 500 6,5 3SF78 44 4/3/2 300/400/500 0,8 ... 18 4/3/2 300/400/500 6 ... 60 2 500 6,5 BR_Sicherheitssensoren_Eng.fm Seite 16 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 17 Connection Bus Protective field height (mm) Product selection code M12 Cable gland Hirschmann Brad Harrison for NAFTA AS-Interface/ ASIsafe PROFIBUS/ PROFIsafe 300 ... 1800 3RG78 46
150 ... 1800
600 ... 1800
150 ... 1800 3RG78 43
450 ... 1800
150 ... 1800 3RG78 41
300 ... 1800
450 ... 1800
150 ... 1800 3RG78 45
450 ... 3000
750 ... 3000
150 ... 1800 3SF78 42
450 ... 3000
750 ... 3000
150 ... 1800 3RG78 44 450 ... 3000
300 ... 1800 3SF78 44 Connection Bus Number of beams Product selection code M12 Cable gland Hirschmann Brad Harrison for NAFTA AS-Interface/ ASIsafe PROFIBUS/ PROFIsafe 0.8 ... 18 0.8 ... 18 4/3/2 3RG78 45 6 ... 60 6 ... 60 4/3/2 6.5 6.5 2 0.8 ... 18 0.8 ... 18 4/3/2 3SF78 42 6 ... 60 6 ... 60 4 6.5 6.5 2 0.8 ... 18 0.8 ... 18 4/3/2 3RG78 44 6 ... 60 6 ... 60 4/3/2 6.5 6.5 2 0.8 ... 18 0.8 ... 18 4/3/2 3SF78 44 6 ... 60 6 ... 60 4/3/2 6.5 6.5 2 BR_Sicherheitssensoren_Eng.fm Seite 17 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS400 light curtains, light grids and transceivers 18 Evaluation units and accessories Evaluation units The evaluation units form a flexible product family of interface modules for light curtains and light grids. The modular device series can be used up to type 4 according to IEC/ EN 61496, SIL 3 according to IEC/EN 61508, or PL e according to EN ISO 13849-1. They expand the functionality of the light curtains and grids to include startup/restart inhibit and contactor control as well as cycle control and muting depending on the device version. This product family also offers an extensive range of addition- al functions such as early error warning for the relay contacts, a PC diagnostics function, as well as many signaling outputs to a higher-level controller. Versions: Type 2 and 4 according to IEC/EN 61496 - Relay module, dual-channel, for AOPDs with 2 OSSDs and contactor control Type 2 according to IEC/EN 61496 - Standard, restart inhibit, contactor control (suitable for 3RG7841 light curtains and 3RG7823 light barriers) PL-e, category 4 according to EN ISO 13849-1: 2006 - one or two-channel EMERGENCY STOP circuit and protec- tive door monitoring - Sequential circuit for safety light barriers, types 2 and 4 - Automatic or manual start - 3 release circuits, 1 NC contact as auxiliary circuit Type 4 according to IEC/EN 61496 - Muting function, restart inhibit, contactor control Accessories For simple installation and rapid commissioning of light cur- tains and light grids, a practical range of accessories is avail- able. The light curtains and light grids for floor mounting can thus be mounted and adjusted ruggedly in mounting columns of different lengths without additional lateral mounts. An appropriate mounting system is available for the efficient mounting of muting sensors. With the installation of optional protective screens, damage and scratches on the devices can also be avoided in difficult ambient conditions, thus increas- ing the availability of the machinery. ASIsafe modules are available with high degrees of protection to allow cost-effective connection of conventional light cur- tains, grids and transceivers to the the AS-Interface Safety at Work on the field level. Our range Mounting columns, reflective mirror columns, and reflective mirrors for light curtains Protective screens Mounting hardware supports, muting assembly systems Safety key for teach-in ASIsafe modules and adapters Cables and cable boxes BR_Sicherheitssensoren_Eng.fm Seite 18 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS600 laser scanners 19 SIMATIC FS600 laser scanners An all-round view for safety The SIMATIC FS600 laser scanners work over an angle of 190 and at a distance of up to 6.25 m. In this area, the laser scanner reliably detects any persons and objects. It works like this: The distance sensor emits light pulses at reg- ular intervals. If they hit an obstruction, the sensor receives the reflected light and evaluates it. If this is evaluated as the predefined area to be protected, a stop function is triggered. With up to 8 programmable protective field pairs that can be selected during operation, our laser scanners can be optimally adapted to any application on machines, production robots, conveyor systems, or vehicles. Different versions support optimal integration in the automa- tion system: Conventionally in the safety circuit, over PROFIBUS with PROFIsafe, or over AS-Interface with ASIsafe. Standard applications Vertical as well as horizontal danger zone protection with multiple protective fields Safeguarding of hazard points (hand and arm protection) Traverse path monitoring for automated guided vehicle systems Collision protection for material handling equipment with linear traverse path Area protection and access control Certifications: Cat. 3 according to EN 954-1 Type 3 IEC/EN 61496-1,-3 SIL 2 according to EN 61508 Benefits at a glance Vertical as well as horizontal protection Working angle of 190 Warning field range of 15 m Working ranges of up to 6.25 m Up to 8 different protective fields Field pair switchover is possible during operation Velocity-dependent protective zone switchover with- out additional incremental encoders Parameterization using LS4Soft Automatic configuration when replacing the device by means of the Config-Plug Finely granular protective zone pair parameteriza- tion supports flexible adaptation to the environ- ment Versions with standard connection, AS-Interface with ASIsafe and PROFIBUS with PROFIsafe Properties/ versions SIMATIC FS620 SIMATIC FS660 SIMATIC FS670 Protective field ranges 4 2.15 4 6.25 2.15 4 6.25 Resolution in mm 70/150 70/150 30-50/70/150 30-50/70/150 70/150 30-50/70/150 30-50/70/150 Number of selectable field pairs 4 4 8 8 4 8 8 Vertical applications Horizontal applications Motion monitoring AS-i/ASIsafe interface PROFIBUS/PROFIsafe interface
BR_Sicherheitssensoren_Eng.fm Seite 19 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS600 laser scanners 20 Laser scanner for small protection zones and motion monitoring Application in small protection zones The SIMATIC FS660 SR (Short Range) laser scanner has been designed for safety engineering applications in small protec- tion zones of up to 2.15 m. Based on the functionality of the FS660I devices with horizontal and vertical protection, the la- ser scanner also impresses customers with its attractive price. Applications: Automated guided vehicle systems with low speeds and short braking distances (usually 1.5 to 2 m) Stationary use for access protection at low entrances, e.g. at robot cells, or for area protection on punches or presses Motion monitoring for material handling equipment with linear traverse path The SIMATIC FS670 laser scanners for motion monitoring have been specially designed for applications material handling equipment with linear traverse path. In addition to the stan- dard safety functions for operator protection, it reliably calcu- lates distances for positioning as well as velocities. It monitors up to 6 different velocities and will automatically correct the selected protective field if necessary. No additional incremental encoders are required due to the integrated ve- locity calculation - the safety laser scanner and the standard PLC together execute all the functions of velocity-dependent monitoring of the protective field. Benefits at a glance SIMATIC FS670 Distance measurement for positioning Eight programmable and switchable protective zones with different ranges of 2.15, 4, and 6.25 m Resolution adjustable from 30 to 150 mm Velocity measurement for the selected protective field and, if necessary, correction, warning, as well as monitoring of the maximum velocity Automatic calculation of the protective fields for motion monitoring with LS4Soft software Maximum reliability even in case of temporary disturbances in the measuring zone Up to 6 different velocities can be monitored Orientation requires just a fixed reference value (e.g. a wall) No need for additional incremental encoders due to integral velocity monitoring No additional safety PLC required for protective field switchover LS4Soft software Collision protection for shifting units Traverse path monitoring for automated guided vehicle systems Horizontal danger zone protection BR_Sicherheitssensoren_Eng.fm Seite 20 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 SIMATIC FS600 laser scanners 21 Technology overview Find the right product faster with the product selection code! There is more information on the use of the product selection code on page 22. Protective field data Operator protection zone Warning zone Detection zone Up to 6.25 m Up to 15 m Reflective capability min. 1.8% min. 20% Object size 30, 40, 50, 70, and 150 mm 150 mm x 150 mm Response time min. 80 ms min. 80 ms Output 2 fail-safe PNP transistor outputs 24 V/250 mA or secure ASIsafe and PROFIsafe connection PNP transistor output, max. 100 mA or ASIsafe and PROFIsafe bus connection General data Standard AS-Interface PROFIBUS Scanning range 190 190 190 Scan rate 25 scans/s or 40 ms/scan 25 scans/s or 40 ms/scan 25 scans/s or 40 ms/scan Angle resolution 0.36 0.36 0.36 Lateral resolution 0.36 0.36 0.36 Measuring errors max. 83 mm (with protective zone radius < 3.5 m), max. 100 mm (with protective zone radius > 3.5 m) Laser protection class Class 1 (safe for eyes), DIN EN 60825-1 Inputs Restart/reset Connection of a command device for operating mode "with restart inhibit" and/or device reset, dynamically monitored, 24 V DC opto-decoupled Field pair switchover Selection of 4 field pairs over 4 control lines with internal monitoring (1 field pair = 1 protective zone and 1 warning zone), 24 V DC opto-decoupled via PROFIBUS (PROFIsafe profile) Outputs Protective field 2 x safe semiconductor output, PNP max. 250 mA, short-circuit monitoring, protected against overcurrent AS-Interface, secure slave (ASIsafe profile) PROFIBUS, secure slave (PROFIsafe profile) Warning zone/fouling/fault PNP transistor output, max. 100 mA AS-Interface PROFIBUS Interfaces RS422 RS232 RS232 Degree of protection IP65 according to IEC 60529 IP65 according to IEC 60529 IP65 according to IEC 60529 Touch protection Safety class 2 Safety class 2 Safety class 2 Operating temperature 0 to + 50 C 0 to + 50 C 0 to + 50 C Storage temperature -20 C to + 60 C -20 C to + 60 C -20 C to + 60 C Humidity DIN 40040, Table 10, identification letter E (fairly dry) Vibratory load over 3 axes according to IEC 60068 parts 26, 10150 Hz max. 5 G Continuous shock over 3 axes according to IEC 60068 parts 229, 10 G, 16 ms Noise immunity according to DIN EN 61496-1 (meets the requirements for type 4); also according to DIN 40839-1/3; test pulses 1, 2, 3 a, 3 b, and 5 (not for use in vehicles with internal combustion engines) according to DIN EN 61496-1 (meets the requirements for type 4); also according to DIN 40839-1/3 according to DIN EN 61496-1 (meets the requirements for type 4); also according to DIN 40839-1/3 Product selection code 3RG7834 3SF7834-6D 3SF7834-6P BR_Sicherheitssensoren_Eng.fm Seite 21 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 All you need to know about fail-safe sensors SIMATIC FS 22 All you need to know about fail-safe sensors SIMATIC FS Information Simply download catalogs and information material The Siemens Information and Download Center contains all the current catalogs, customer magazines, brochures, demon- stration software, and promotion packages ready for you to down- load. Alternatively, you can order them. This includes our catalogs "Safety Integrated" and "SIMATIC Sensors FS10". www.siemens.com/safety-integrated -> support -> infomaterial Newsletter Always up to date: The latest information about safety technology can be found in our regular newsletter. You can register at: www.siemens.com/safety-integrated -> newscenter -> newsletter Planning 2D and 3D construction data in the image database To support you efficiently in your construction, configuration, and documentation processes, for the most important products of our fail-safe sensors portfolio we offer 2D and 3D construction data at: www.siemens.com/simatic-sensors/fs-cad Here, powerful search functions such as order number, product name, 3D, or CAD help you find the data for the required product quickly. Order Find and order the right fail-safe sensor easily and quickly Our interactive catalog on DVD or our electronic catalog and ordering system on the Internet (I IA DT Mall) at: www.siemens.com/automation/mall offers you a detailed overview of our comprehensive range of fail-safe sensors. As a registered user, you can even order your selected products immediately. Choosing the right fail-safe sensor: Product tree In the Mall under "Products" on the left, you will find our product tree. Under "Sensors, measuring and testing technology" you are just a few clicks away from our fail-safe sensors. Product search You can also enter a search term in the "Product search" field (top right) to find the desired products. Product selection code It is even faster to use the product selection code to access a list of relevant fail-safe sensors. You can find the specific product selection code in the tables in this brochure. You can also enter this code in the "Product search" field in the upper right, and the relevant products will appear immediately onscreen. BR_Sicherheitssensoren_Eng.fm Seite 22 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 All you need to know about fail-safe sensors SIMATIC FS 23 Commissioning/operation Online support The online support with its comprehensive information system and many types of services is available around the clock. From documentation, applications, tools, and FAQs to software updates to the Online Support Request and Technical Forum: http://support.automation.siemens.com Well-served on site: Solution Partners To meet the increasing require- ments in safety technology, Siemens also relies on selected "Siemens Solution Partners Automation". These highly qualified partner companies offer professional advice and support for all relevant safety aspects of your automation projects. www.automation.siemens.com/solutionpartner Service Technical support We offer worldwide support in the local language. Competent answers to technical questions, about spare parts, repairs, service contracts. www.siemens.com/automation/support-request Training Training At various locations worldwide, our Training Centers offer individual advanced training programs about all aspects of automation as well as industrial solutions. Specific to safety technology, we offer courses about the current standards and our comprehensive range of products and solutions. You can find everything you need to know about our comprehensive SITRAIN training program online at: www.siemens.com/sitrain-safetyintegrated Alternatively, you can contact us directly: Information via telephone: 01805/25 36 11 Fax: 01805/23 56 12 Step-by-step creation of standards-compliant machine documentation with the Safety Evaluation Tool The Safety Evaluation Tool for the IEC 62061 and ISO 13849-1 standards takes you directly to your goal. This TV-tested online tool from the Siemens Safety Integrated program helps you to evaluate the safety functions of your machine quickly and reliably. You will receive the results as a standards-compliant report that can be integrated in the documentation as proof of safety. More information: www.siemens.com/safety-evaluation-tool BR_Sicherheitssensoren_Eng.fm Seite 23 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009 The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Get more information Product information for SIMATIC Sensors: www.siemens.com/simatic-sensors Easily and quickly find the right fail-safe sensor and order it: www.siemens.com/simatic-sensors Product information on Safety Integrated: www.siemens.com/safety-integrated Ordering on the Internet: www.siemens.com/automation/mall Your personal contact nearby: www.siemens.com/automation/partner Service and support: www.siemens.com/automation/service&support Training for SIMATIC Sensors: www.sitrain.com Partners for your automation solutions Siemens Automation Solution Providers: www.siemens.com/automation/solution-provider Systems partners of SIMATIC sensors: www.siemens.com/simatic-sensors/partner Siemens AG Industry Sector Sensors and Communication P.O. Box 48 48 90327 NRNBERG GERMANY Subject to change without notice. Order No.: 6ZB5330-0AJ02-0BA2 3P.8101.65.07 / Dispo 26107 BR 0409 3.0 ROT 24 En Printed in Germany Siemens AG 2009 www.siemens.com/automation BR_Sicherheitssensoren_Eng.fm Seite 24 Mittwoch, 1. April 2009 5:21 17 Siemens AG 2009