You are on page 1of 5

Efciency of temperature till 92%

Economic usage of energy


Silent operation
Integrated automatic control
DOMEKT
Energy saving ventilation
air handling units designed
for residential premise
3 2 UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
Is the natural ventilation
the cheapest conventional
solution?
Does a conditioner
change the ventilation
system?
Is the installation of
ventilation system
complicated and
expensive?
The natural ventilation is inefcient in modern and reconstructed buildings where hermetic
glass package and heat insulations of the walls are used. Moreover, the consumer is not pro-
tected from smells penetrating of next fats, draught, noise and cold weather. There is also
no chance to control air change parameters.
A conditioner does not ensure the provision of fresh air and so it just regulates the tempera-
ture of the premise and makes the air cold or warm.
The consumed and polluted air constantly circulates in the premise due to the work of con-
ditioner ventilators. This decision within a balanced ventilation system makes good condi-
tions for the multiplication of bacterium and fungal. Air parameters are getting worse in the
premise and allergic illnesses are caused.
Contemporary supply-exhaust ventilation equipment with heat recovery and integrated
automatic control is made so that the installation would be mostly simplifed. Such a unit
could be valued as everyday unit which can be used at every fat. The question of a sys-
tem price is individual and depends on a project-based solution but the beneft of a system
usage and (having analyzed the reduction of charges) prices as well as obtainable ratio of
beneft ensure the accessibility of his system for every contemporary consumer which is
concerned for his family health and welfare.
KOMFOVENT supply and exhaust air handling unit with heat recovery
is a reliable solution for any type of residential area
Prevailing stereotypes
The central system of mechanical ventilation is rather
expensive and so it is unintended for older fats or
individual houses.
Plenty of heat is lost providing air through open windows
and removing it from a toilet, kitchen. It is cheap for
installation and expensive for exploitation.
KOMFOVENT DOMEKT individual ventilation system
is created not only to ensure healthy microclimate in
residential premise but also to do it economically.
The air of polluted
premise
Allergens
The humidity
and the must
The loss of heating
The consequences of the absence of ventilation
People activity, computers, furniture, carpeting, contemporary building materials and a lot
of other details that surround us everyday exclude the injurants. It is hard to believe that
sometimes the concentration of injurants inside can exceed about 100 times than outside.
Children and elder people are especially sensitive for the environment pollution.
The most popular decision is to ventilate the premise opening the windows or the balcony.
What about a draught, noise, a loss of heating in winter, overheated air blowing in summer,
insects and motes. The consequences of this decision are discomfort, worse self-feeling
and additional charges.
The number of people sufering from allergy increases every year. Research data states that
children are more likely to sufer from allergy which may lead to bronchial asthma.
The pollen, dust particles, domestic ticks, fungal and the must are all the allergens in the
air and often cause allergic reaction. Ventilation reduces the concentration of allergens in a
ventilated premise, therefore the risk of illness is also reduced.
If the window or the balcony is open the situation may get worse because unfltered air will
be blown into premise with pollen, dust etc.
Hermetic windows, doors, additional walls heat insulation and fashing ensure heat preser-
vation in premise and save the energy. The air does not remain in insufciently ventilating
premise. If there is no ventilating, the warm air condenses on cold walls and windows.
The microclimat of such premise is inevitably getting worse and the humidity excess makes
a negative impact on interior beauty. The excess of water steam in the air and the concen-
tration are the best conditions for the development of the must fungal. The consequence
of the vital activity of fungal is not only the beauty destruction of the walls and ceiling but
also the allergic reactions to people.
Up to 65% of the warm is used for the heating of fresh blown air in modern buildings.
This is why natural ventilation is the essential reason for the loss of heating and additional
charges.
The installation of an economical ventilation system with heat recovering solves this prob-
lem easily at the same time reducing charges of heating and electrical energy at most.
We spend up to 90% of our time in closed premise and we rarely think of
the air we breath. Fresh and clear air is vitally essential and important but
we pay much more attention for food, water and everything else what
we see, feel and touch. Human health and self-feeling depend on many
circumstances that create all the complex. Everyone is certain that fresh air
creates good conditions for a good mood. It also improves self-feeling and
increases working capacity.
What is the air which we are forced to breath in our fats where we spend
most of our time and rest commonly? Why does the number of people who
sufer from allergy increase every year?
Healthy indoor climate and energy saving
5 4 UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
Possible ways of installation of KOMFOVENT DOMEKT units:
With directly integrated kitchen
hood KOMFOVENT
(only for REGO 200V)
With separately connected
kitchen hood KOMFOVENT
Balanced ventilation system in the
premise.
When the kitchen hood is switched
on, the supply air fow in the unit
increases and the exhaust one
decreases automatically. This way we
can feel the supply/exhaust air fows
balance in the premise.
With separately connected
additional extract air difusers.
If a kitchen hood is not used,
an extraction difuser from the
bathroom, laundry, or other premise
can be connected to the unit as well.
Outdoor air
Supplied air
Exhausted air from premise
Exhausted air outside
Exhausted air without regeneration (e.g. from a cooker, a toilet etc.)
The rotary or plate heat exchanger which uses the heat from
the removed air for heating the provided air is integrated in
all ventilation units. The process of heat utilization (usually
known as a process of recovering) helps to save up to 90%
expenditures used for the heating of supplied air and up to
30% expenditures used for the heating of premises.
Energy saving units maintain controllable air change and
provide an opportunity for an inhabitant to independently
control the ventilation intensity.
The usage of such energy saving technologies is as oppor-
tunity noticeably to save the expenses during the heating
season. It also ensures comfortable parameters of tempera-
ture, humidity and clean, fltered air in the premise that ob-
viously ensures healthy microclimate in premises.
KOMFOVENT DOMEKT ventilation equipment provides the
consumer an opportunity to create an individual ventila-
tion system which is independent from all the multistorey
house and neighbours. The equipment is created so that it
would be easy to change the current old air extraction sys-
tem through the hood and air supply through the window.
DOMEKT series air handling units are designed for the
ventilation of residential premise that possess an area from
40 m
2
till 250 m
2
.
Two functions in one DOMEKT unit:
1. Premise ventilation i.e. air supply to premise removing it
and recovering the heat.
2. Extraction of the used air froma cooker or a toilet at the
same time keeping air provision/removing balance in
the premise.
Helps to save up to 92%of heat.
Air handling units are fully prepared for installation: just
PLUG&PLAY.
DOMEKT air handling units are especially silent.
Air handling units with ECmotors. High coefcient of
efciency of an ECmotor causes lowusage of energy.
Acompact construction of air handling unit and a
universal construction help to integrate it in a set of
kitchen furniture. It is also possible to hang themon the
wall, ceiling, or to put it on the foor.
Special design of the units no need to specify the
inspection side it is both right and left hand in one.
It is possible to choose a modern touch sensitive control
panel C4 PLUS.
PLU
G

&
PLAY
7 6 UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units. UAB AMALVA reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
Quick selection
of a DOMEKT unit:
REGO 200V REGO 400V REGO250P REGO 400P REGO 600H RECU 300V RECU 400V CF RECU 450V RECU 500P CF
Residential area, m
2
40-120 m
2
121-190 m
2
Air fow, m
3
/h
50-230 m
3
/h
240-400 m
3
/h
410-600 m
3
/h
Mounting place:
On the wall
On the foor
Under the ceiling
The type of the heat exchanger:
Rotary
The temperature
efciency up to 89%
The temperature
efciency up to 90%
The temperature
efciency up to 87%
The temperature
efciency up to 88%
The temperature
efciency up to 88%
Plate The temperature
efciency up to 89%
The temperature
efciency up to 88%
The temperature
efciency up to 89%
The temperature
efciency up to 92%
A comfortable control system for the consumer
Your selected air handling unit has an integrated automatic control.
Every consumer can choose a desirable automatic control panel:
Touch sensitive control panel (additional)
Modern smart solution
Have additional functions
A standard control panel
Simple and comfortable use
Have main functions of control
What should be known if you want to choose the most suitable ventilation unit?
Ventilation is characterised by amount of the air and the frequency of air change. The amount of air is the volume of air in
premise (m
3
). The frequency of air circulation shows how many times the air changes in premise per hour.
The frequency of air change recommended in residential premise is at least one time for comfortable conditions.
Consequently, such a simple formula can be used to estimate in advance the airfow of the unit:
For instance: residential area is 75 m
2
, ceiling height is 2,7 m, consequently: 75 2,7 1,0 = 202 m
3
/h
The aproximate airfow of a unit (air supply/exhausted air) will be about 200 m
3
/h.
The quadrature of
a living area
(m
2
)

The height of
a residential
premise (m)

The frequency
of air circulation
1,0 h
-1
This estimate is not the rule; the necessary airfow of a unit can be noticeably higher because the frequency may be esti-
mated according to the efect that we are seeking.
The most accurate data necessary to ensure the efective ventilation will be provided by a professional who designs your sys-
tem. If you want to choose a unit quickly in advance you may know just an area and estimate the usage of the air by formula.
You may also foresee possible type of units mounting and choose the type of a recuperator.
The full selection of units with all the technical characteristics available on webpage: www.komfovent.com, DOMEKT section quick selection.
2
3
6
9
12
8
7
10
11
5
4
1
or
12
11
6
4
9
A
B
D
C
E
F
Principal mounting system of KOMFOVENT DOMEKT air handling unit
C4 PLUS
C4
Ventilation systems elements
KOMFOVENT producer:
UAB Amalva
Ozo str. 10, LT-08200 Vilnius, Lithuania
info@komfovent.com
www.komfovent.com
2013
1 Unit DOMEKT REGO 200V
2 Painted front panel, stainless steel panel is optional
3
Kitchen hood (can be enclosed according to a customers request,
possible connection of other extraction devices)
4 Remote control panel C4 or touch sensitive C4 PLUS
5 Grille
6 Difuser
7 Return valve
8 Outdoor grill (for air supply/extraction)
9 Damper with actuator
10 Insulated duct
11 Regulating damper
12 Silencer
A Outdoor intake
B Supply air
C Extract indoor
D Exhaust air
E Additional extraction (by-pass damper extraction without heat recovery)
F Extracted air from the kitchen (by-pass damper extraction without heat recovery)