The Company was established in 1992 after ownership

changes of Electric and Energy Management Department


of ZPBE Energopomiar Gliwice.
We continue activities of ZPBE Energopomiar and use
tens of years experience in work for power industry.
We employ high-qualified engineers and technicians,
with long-time experience, what guarantees professional
service and quality of our products.
The Company policy is that all employees take part in
meeting customers requirements, by realizing and
promotion of principle:
It is assured by our laboratories certified in Polish Centre
of Accreditation:
Measuring Devices Laboratory
(certificate no. AP 063) for calibration of control and me-
asurement apparatus
Testing Laboratory of Switchgears and Substations
(certificate no. AB269) which deals with:
inspection and testing technical properties of low and
medium voltage apparatus, accessories and devices,
research of 50 Hz electromagnetic field (produced by
power and industrial sources) influence on people and
environment,
thermovision inspections of temperature distribution in
power apparatus,
measurements of noise, produced by industrial and en-
ergy objects and HV transmission lines,
PD measurements in electrical apparatus.
COMPANY
CORE BUSSINESS IS:
services and measurement research work for the
power engineering and for other branches of industry
comprising all stages of electric energy management,
beginning with generation, through transmission and
distribution and ending with all ways of utilization;
full engineering service at building/production/
operation and refurbishment stages of power industry
objects (Contract Supervisor),
technical consulting in selecting new project solutions,
devices, protection systems and equipment used in
power engineering and in other branches of industry;
tests and evaluation of electrical power engineering
equipment,
comprehensive work connected with environment
protection against noise, vibrations, electric and
magnetic field, as well as hazard caused by electric
energy devices under voltage,
expertise and post-fault analysis,
expert opinions about introducing green energy sources
into National Power System,
production of test and measurement equipment as
well as diagnostics apparatus.
Power Research and Testing Company

ENERGOPOM1AR-ELEKTRYKA

Ltd.
QUALITY
IS NOT INCIDENT
Detailed description of our services and production scope is on
our internet page: www.elektryka.com.pl
Advanced technology and
functionality are attributes
of control-measurement and
diagnostics devices produced by
Energopomiar-Elektryka.
Our devices are developed on the base of Customers needs and opera-
tion experience. Close co-operation with users allows to optimize tech-
nical features and measurement abilities.
Ordered devices could be independently checked in our Measuring De-
vices Laboratory (including accredited scope Accreditation Certificate
AP 063).
We offer devices for following applications:
current transformers testing,
switch tests,
transformer diagnostics and protection,
transport assessment of transformers and generators,
loading of measuring transformers,
measurement of electrical energy parameters,
time measurements,
transient recordings,
testing of electric energy meters,
checking resistance of bolted joints,
verifying of current releases,
synchronization and parallel connection of two power
energy systems,
testing of earthing systems,
testing of Electronic Protection Systems,
ferroresonance signals suppression,
LV and MV lines protection,
telecontrol.
C O N T E N T S
three-phase circuit analyser
type ANOT-10 .............................. 2
control meter
type LK-10 .................................... 4
meter test device
type TL-1 ...................................... 6
transformer diagnostic device
type UDT-2................................... 8
Gas-in-Oil-Analysis System
with Transformer
Monitoring Functions
type Hydrocal -1003/1005 .......... 10
transformers tap-changer
position indicator
type PZT-30 ................................ 12
shock recorder
type RW-1 .................................. 14
microprocessor-controlled
chronograph
type SM-1 .................................. 16
phase shifter
type PF ....................................... 18
three-phase voltage generator
type GU3F .................................. 20
current source
type PWPN-1 .............................. 22
telecontrol device
type RL-64D ............................... 24
switch contacts
anticoincidence meter
type MND-26 ............................. 26
DC current source
type WPS-300 / WPS-600 ........... 28
power supply for switchs coils
type ZCW-1 ................................ 30
electrocution voltage selector
type ZNR-1 ................................. 32
electrocution voltage selector
type ZNR-2 ................................. 34
electrocution voltage meter
type MNR-1 ............................... 36
current source
type WP-100 .............................. 38
current source
type WP-1000 ............................ 40
current source
type WPu-4000 .......................... 42
DC/AC current source
type WPPS-300 .......................... 44
current transformer testing device
type TP-100................................ 46
ANOT-10
[three-phase circuit analyser]
2
AC current measurement ranges: 5 A, 15 A (with Dietz clamp meter or current loop: 700 A)
Allowable uncertainty of AC current measurement (0,1 % of reading + 1 digit)
AC voltage measurement Ranges: 450 + 10 % V single phase voltage; 780 + 10 % V interfacial voltage
Allowable uncertainty of AC voltage measurement (0,1 % of reading + 1 digit)
Active, reactive and apparent power measurement Ranges: up to 2000 (VA, W, var) for Aaron circuit: up to 25003 W
Allowable uncertainty
of active and apparent power measurement
of reactive power measurement
(0,2 % of reading + 2 digits)
(0,5 % of reading + 2 digits)
Active, reactive and apparent energy measurement
Range: 1000 kWh. Measurement control by: STOP button, probe, voltage or current
appearance.
Allowable uncertainty of active, reactive and apparent energy
measurement
(0,5 % of reading + 5 digits)
Phase angle measurement Range: 180
Allowable uncertainty of phase angle measurement (0,5 % of reading. + 1 digit) for voltage >10 V
Frequency Range: 48 52 Hz
Allowable uncertainty of frequency measurement (0,1 % of reading + 1 digit)
Phase rotation indicator Min. voltage: 10 V
Operation temperature -5 C +40 C
Enclosure protection IP 67
Power supply 90 250 V, 50 Hz
Dimensions 460 x 350 x 115 mm
Weight about 10 kg
DESCRIPTION
Analyser is useful for energy meter testing, checking of current
transformer, determination of phase rotation and three-phase
circuits symmetry, harmonic analysis and vector diagram
plotting. Results are correct also for signals with distortion (True
RMS). Automatic range changing and matching to network
voltage increase device compatibility. Type of measurement is
selected from keyboard. Internal memory allows data recording,
with cyclic saving more than 4000 (more than 2000 in older
version) measurement results.
Analyser with Dietz clamps is placed in measuring box.
3
PURPOSE
Analyser is assigned for measurements and recording of one-phase and three-phase network parameters. Results of
measurements are shown on display and, through RS232 interface, can be sent to computer and printed. ANOT-10 can
measure:
one-phase and multi-phase voltage in one- and three-phase circuits,
phase currents,
active, reactive and apparent power in one- and three-phase circuits and in Aron circuit,
active power of arbitrary combination of currents and voltages (for checking connection correctness in three phase
circuit),
active, reactive and apparent energy,
energy meter error and ratio of current transformers,
frequency, harmonics and transients,
angle between currents and voltages in three phase circuit.
LK-10
[control meter]
4
Voltage range
45270 V resolution:
0,01 V for U(L) < 100 V; 0,1 V for U(L) > 100 V
Current range (direct measurement) up to 10 A; resolution: 0,001 A
Current range (indirect measurement) clamp meter
up to 100 A; resolution: 0,01 A;
of clamp meter hole 12 mm
Direct measurement:
allowable uncertainty of voltage and current measurement
allowable uncertainty of active power and energy measurement
allowable uncertainty of reactive power and energy measurement
(0,1 % of reading + 1 digit)
(0,2 % of reading + 1 digit)
(0,5 % of reading + 1 digit)
Indirect measurement clamp meter
allowable uncertainty of current, power and energy measurement
(1 % of reading +1 digit)
Rated power consumption 14 VA
Voltage inputs U1, U2, U3, N
Current inputs I1, I2, I3
Inputs: clamp meter Dietz clamp meter up to 100 A
Inputs: measuring head ... ... meters type GL-10; ... manual type GR-10
Operation temperature -5 C +40 C
Enclosure protection IP 67
Power supply (mains)
Power supply (from measured circuit)
100 240 V, 50 Hz
230 V, 50 Hz
Dimensions 380 x 260 x 130 mm
Weight about 2 kg
DESCRIPTION
Control meter accuracy is defined at level 0.1%. Direct and indirect
(Dietz clamps) currents inputs extend meters usability. It is possible
to connect meter head (e.g. GL-10) and hand probe (e.g. GR-10)
for checking slow-running meters.
The possibility of test report direct printing on thermal printer,
connected to control meter is a very useful facility.
LK-10 meter enables determining the error of meters counter,
direction of phase rotation and measurements (True RMS) of
voltages, currents, power and energy.
Control meter is small and lightweight, its safety and tightness
enclosure provides good protection in rough operating
conditions.
This device is assigned for Power Utility services, it is specially useful
in fighting against illegal power consumption, combined with
neodymium magnets applying.
Very high accuracy class and low, competitive price are additional
features of the meter.
5
PURPOSE
Control meter LK-10 enables uncertainty determination of induction and electronic energy (active and reactive) meters, as
well as measurement of basic parameters of one- and three phase networks.
TL-1
[meter test device]
Rated power consumption 3 VA
Power settings for meter test 5 65 W or 1000 W
Current range
with resolution
up to 10 A
0,001 A
Max. displayed measurement uncertainty -100 % +1000 %
Allowable uncertainty (0,5% of reading + 1 digit)
Operation temperature -5 C +40 C
Power supply (from measuring phase) 230 V, 50 Hz
Dimensions 250(190) x 95 x 45 mm
Weight about 0,75 kg
6
DESCRIPTION
Meter test device TL-1 has suitable ABS enclosure and a leather
case, which make easy handling of device and its accessories.
TL-1 is energized from internal battery or power network, from
which tested meter is supplied.
In upper part of enclosure there is a socket with pin probes (or
cables) and Neutral cable, ended with clamp for connection to
meters terminal strip.
The socket for measuring head (for automatic uncertainty
measurements of induction and electronic meters) is placed in
bottom part of enclosure. The head with a stand is an optional
accessory of device TL-1.
The device TL-1 is equipped with keyboard and LCD display for
showing measurements results and messages.
In TL-1 memory are saved 12 mostly occurred meters factors,
but user can insert any other factor.
Before start of meter checking, user should disconnect meters
current coil from consumer electric circuit.
Current flow through meters current coil is forced by internal
TL-1 circuit. This solution made possible elimination of additional
device for meters load (e.g. so-called dryer).
TL-1 device enables meter testing with power about 1000 W,
and measurement of meters starting current using step load
(with step 5 W) in range 565 W, what is 0.5% of rated current
for many meters.
Advantages:
no external power source, which emits a lot of heat,
quick connection to meter (disconnected only meters load),
display of percentage error of checked meter,
power supply from measuring circuit,
leather case for device with accessories.
PURPOSE
Microprocessor controlled device TL-1 is assigned for quick on-site meter testing. Percentage error of meter and its
starting current are checked. Easy maintenance and simple connection make possible checking of almost every induction
and electronic meter, in one- or three-phase circuit. On site test requires only disconnection of the meters current coil
from after-meter consumers circuit.
7
UDT-2
[transformer diagnostic device]
8
OLTC characteristic self-time measurement max. measurement duration time 300 s
Exciting current measurement 0 100 mA AC
Resistance measurement 1 m 100
Regulating range of resistance measurement current 0 15 A DC
Regulating range of resistance measurement voltage 0 30 V DC
Transformer ratio measurement 1/ 3 50
Torque of motor driving OLTC measurement max. measured motor power 6 kW
Operation temperature -5 C +40 C
Power supply 230 V, 50 Hz
Dimensions
560 x 420 x 170 mm
(without transportation box))
Weight about 14 kg
PURPOSE
Transformer Diagnostic Device type UDT-2 is appropriate for after-assembly, periodic and after-fault measurements of
transformers, operating in power industry, according to Transformer Maintenance Manual (IET 2006), agreed with main
transformer manufacturers and diagnostics companies in Poland.
Every UDT device is checked and certified by Measurement Devices Laboratory (accredited by PCA cert. no. AP 063). Measuring
software is subjected to change in order to meet Customer needs, upgrades are periodically delivered to Customers.
DESCRIPTION
Device components:
mobile computer (notebook), connected with measurement
cassette by USB interface,
measurement cassette Euro3U, with galvanic separation 3 kV,
current source for resistance measurement and OLTC
tests,
Windows XP system.
Options and accessories:
torque of motor driving OLTC measurement,
cables with silicone insulation,
transportation box,
additional cables with terminals for simultaneous
connection of all transformer phases.
Software:
designed for Windows XP system,
co-operation with Excel spreadsheet, with automatic
reporting,
intuitive using of all measurement functions
Warranty service: 24 months
After-warranty service with preference conditions.
9
HYDROCAL-1003/1005
[Gas-in-Oil-Analysis System with Transformer Monitoring
Functions]
10
Hydrocal 1003 Hydrocal 1005
M
e
a
s
u
r
e
d

c
o
n
c
e
n
t
r
a
t
i
o
n
s
Hydrogen H2 0 ppm 2.000 ppm 15 % of the measuring value 25 ppm 0 ppm ... 2.000 ppm 15% 25 ppm
Carbon monoxide
CO
0 ppm ... 2.000 ppm 20 % of the measuring value 25 ppm 0 ppm 2.000 ppm 20% 25 ppm
Moinsture-in-oil
H2O
absolute 0 ppm 100 ppm, 3 % of the measuring value 3 ppm Absolute 0 ppm 100 ppm 3% 3 ppm
Acethylene C2H2 0 ppm 2.000 ppm 20% 5 ppm
Ethylene C2H4 0 ppm 2.000 ppm 20% 10 ppm
Operation temperature
Oil Temperature: -20 C ... +90 C
Ambient temperature: -50 C ... +55 C
Analogue inputs
4 x analogue DC inputs: 0/4 ... 20 mA 4x analogue DC inputs: 0/4 ... 20 mA
4 x analogue inputs: 0/4 ... 20 mA / 0 ... 10 V
(configurable by jumpers)
6 x analogue AC inputs: 0 ... 80 V +20%
Analogue outputs
(420 mA)
3 x analogue outputs: 4-20 mA (H2, CO, H2O concentration)
1 x analogue outputs: 4 ... 20 mA (free configurable)
5 x analogue outputs
(H2, C2H2, C2H4, CO, H2O, configurable)
Digital outputs
4 x 12 V relay outputs (20 V DC / V AC, 2A, 60 W)
8 x opto-coupler outputs
5 x 12 V DC-relay outputs
5 x 5 V DC opto-coupler outputs
Communication
RS-232, RS-485, internal on-board modem
(GSM 14.4 kBit / analogue 56 kBit)
RS-232, RS-485, Ethernet
(copper-wired or fibre optical)
Protection class IP 55
Power supply 110 V / 230 V 20 %, max. 350 VA, 50/60 Hz
Dimensions 215 x 215 x 215 mm 263 x 263 x 257 mm
Weight about 8 kg about 9 kg
11
ZVCM - 1001
ZVCM-1001 device, manufactured by ZTZ Services Intl. (USA)
is used for transformer bushings monitoring by test-tap
current measurement. It co-operates with sensors, mounted
on bushing test-tap. Device enables measurement of relative
bushing capacity and dielectric loss factor tan_delta of bushings
insulation. ZVCM-1001 is equipped with serial interface RS232/
RS485 for configuration and communication with SCADA
systems.
Current measurement
range
1 mA 140 mA,
1.5 % of the measuring value,
resolution 0.1mA
Tan_delta measurement
range
0 % 100 %, accuracy
1.5 % of the measuring value,
resolution: 0.01 %
Communication
Serial interface RS-232, RS-485,
protocol MODBUS RTU
Operation temperature -35 C +50 C
Humidity 0 90 %, non-condensing
Power supply 230 V AC, power consumption: 3 W
DESCRIPTION
Hydrocal 1003-1005 (MTE Meter Test Equipment, Switzerland)
Intelligent system for the individual measurement of dissolved
gas in oil contents:
hydrogen (H2) and carbon monoxide CO model 1003
hydrogen (H2), carbon monoxide CO, acetylene (C2H2),
ethylene (C2H4) model 1005
and moisture (H2O) in the insulating oil of power
transformers.
Hydrocal is mounted on a valve on the transformer tank,
without necessity of transformer switch-off.
Graphical firmware Hydrosoft enables Hydrocal parameters
setting and data reading from memory. Hydrocal is equipped
with communication interfaces for connection with external
systems.
Software associated with Hydrocal 1003/1005 system allows:
on-line, remote monitoring of all measured values,
trends of gas-in-oil and moisture content,
notifying user in case of alarm (by SMS too),
communication with external SCADA systems.
Software SMT
(Transformer Monitoring System)
SMT software is made on ASIX platform, which is widely
used for creation SCADA/HMI systems. Besides displaying
actual results of gas-in-oil and moisture-in-oil concentration
measurements, bushings parameters and other measured
quantities, it signalizes transformer status as normal, warning
and alarm.
Data, obtained form Hydrocal and ZVCM devices are stored in
database, and allow determination of trends in chosen time
period.
SMT enables both visualization of cooling system parameters and
OLTC status, in co-operation with cooling system controller.
SMT software provides many possibilities of event reports and
graphical presentation of data. It can collaborate with other
systems, according to Windows data exchange standards (OLE
servers, DDE, OLE2, OLE DB protocols). SMT is fully scalable and
can be matched for monitoring of single transformer, as also
several units in substation or power plant.
PURPOSE
Monitoring system SMT-EE is designed for transformer on-line
diagnostics. It consists of Hydrocal device for gas-in-oil and moisture-
in-oil measurements, ZVCM 1001 device for bushings monitoring
and SMT software for data visualization and processing. Additional
signals from temperature sensors and current transformers could
be use in system, what allows calculation of hot-spot and insulation
ageing rate.
Allowable transmitter-receiver cables
resistance
300
Max. number of tap changer positions 27
Transmitter-receiver code BCD, binary, proprietary
Output receiver code BCD, binary
Current output
0 5 mA
0 20 mA
4 20 mA
Communication RS 485 [MODBUS RTU]
Operation temperature -15 C +40 C
Power supply 230 V, 50 Hz
Transmitter dimensions 170 x 170 x 90 mm
Receiver dimensions 160 x 135 x 67 mm
Transmitter weight 1 kg
Receiver weight 1,5 kg
PZT-30
[transformers tap-changer position indicator]
12
PURPOSE
The newest version of indicators (previous PZT-21 to PZT-29) is PZT-30 device. Tap-changer position indicator is designed for remote
reading of number of actually chosen tap and for recording operation data of tap-changer. Indicator makes possible sending
information about tap position through current output or BCD/digital output and serial interface RS 485 with MODBUS RTU
protocol.
DESCRIPTION
Device is composed of transmitter and receiver. Transmitter
consists of 27 position rotation switch and coder card, which
are coupled mechanically with tap changer. Receiver is installed
on substation area information table, on LCD display are shown:
actual tap-changer position, total number of switchovers from
the moment of position indicator installation, switchover history
with direction (up and down), time and data stamp. Indicator
shows operation statistics: percentage time of operation on
each position.
Indicator enables co-operation with voltage regulator by output
interface: current 0 20 mA or 0 5 mA, or digital: binary or
BCD code.
Serial RS 485 interface (MODBUS RTU protocol) enables
communication between receiver and SCADA system.
13
RW-1
[shock recorder]
Acceleration range -6 g +6 g
Measurement resolution 0,1 g
Measurement and recording axes: X, Y, Z
Memory capacity 4000 measurements
Current consumption about 4 mA
Duration of operation up to 60 days
Communication RS 232
Operation temperature -40 C +85 C
Power supply Lithium battery or AKU
Dimensions 210 x 245 x 105 mm
Weight about 4 kg
14
PURPOSE
Recorder is destined for simultaneous measurement and recording (in three axes: X, Y, Z ) of accelerations (g-load) occurred
during loading, shipment and unloading of transformers, generators, motors, medical equipment and other shock-sensitive
devices.
DESCRIPTION
Recorder is equipped with LCD display and keyboard, for
settings change and calibration related to device mounting.
Recorded data are saved in EPROM memory together with
date and time of event. For better explanation of records, every
power on/off event is recorded.
After operation user can browse saved data directly on LCD
display, print them on internal printer or send to computer
through RS 232 interface.
Software (Windows based) enables visualization of recorded
data.
Recorder has internal battery, which allows continuous
operation during 60 days.
15
Control voltage 5 250 V DC or 50 230 V AC *)
Measurement ranges automatically
selected
0 999,9 ms
0 9,999 s
0 99,99 s
0 999,9 s
0 9999 s
Allowable uncertainty (0,01 % of reading + 1 digit)
Duration of operation without
charging
8 hours
Operation temperature -5 C +40 C
Enclosure protection IP 66
Power supply
internal rechargeable battery with possibility of charging from network
230 V, 50 Hz
Dimensions 230 x 200 x 80 mm
Weight about 2 kg
Warning
*) with AC voltage control, additional inaccuracy may occur: not more than
0,5 ms for 50 V and 0,1 ms for 230 V
SM-1
[microprocessor-controlled chronograph]
16
PURPOSE
Chronograph is assigned for time measurements in electrical power protection automation systems. Internal battery enables
operation in places without proper main power supply.
DESCRIPTION
Chronograph is equipped with 2 separate inputs: start and
stop. It could be controlled by AC/DC voltage appearance or
disappearance or by open/close contacts. The voltage polarity
on inputs is arbitrary.
Chronograph enables following measurements:
pulse duration,
time between pulses appearance,
pulses spacing interval,
relay operation time,
duration of contacts close and open,
sum of several measured times.
17
PF
[phase shifter]
18
Current regulation range 0 2 A, 0 10 A, 0 20 A
Power of current source up to 40 VA
Voltage regulation range 0 120 V
Power of voltage source up to 40 VA
Phase angle regulation range 0 360
Allowable uncertainty
of voltage measurement
(1 % of reading + 1 digit)
Allowable uncertainty
of current measurement
(1 % of reading + 1 digit)
Allowable uncertainty
of phase angle measurement
(1 + 1 digit)
Allowable uncertainty
of time measurement
(0,01 % of reading + 1 digit)
Operation temperature -5 C +40 C
Enclosure protection IP 67
Power supply 230 V, 50 Hz
Dimensions 430 x 320 x 110 mm
Weight about 8 kg
DESCRIPTION
Phase shifter generates on its output alternate current and
voltage (sinusoidal, 50 Hz) with controlled amplitude and
current-voltage phase angle. It is provided with digital voltmeter,
ammeter, time and angle measurement device.
PURPOSE
Phase shifter PF is designed for testing of angle-sensitive protection devices e.g. phase-comparative or earth fault safeguards.
It makes possible measurement of operation angle and start-up time of protection device.
19
Max. output voltage 120 or 300 V
Output power 40 VA / phase
Allowable uncertainty (1 % of reading + 1 digit)
Operation temperature -5 C +40 C
Enclosure protection IP 67
Power supply 230 V, 50 Hz
Dimensions 430 x 320 x 110 mm
Weight 20 kg
GU3F
[three-phase voltage generator]
20
PURPOSE
Voltage generator is assigned for testing devices supplied by three-phase voltages. It enables simulation of system asymmetry and
fault/decay of arbitrary phase voltage. It is used e.g. for protection systems checking.
DESCRIPTION
Single phase supply voltage 50 Hz, after reducing is shifted by
angle 120, for three phase star making. After amplification,
the voltages are fed to output by step-up transformer.
Generator has two-stage voltage control concurrent for
selected phases and separate for each single phase with
possibility of elimination given phase.
21
Current regulation range:
- at range 5 A and load up to 80 m
- at range 20 A and load up to 30 m
0 5 A
0 20 A
Voltage regulation range
with load from 15 k
0 230 V AC
Allowable uncertainty (1 % of reading + 1 digit)
Operation temperature -5 C +40 C
Enclosure protection IP 67
Power supply 230 V, 50 Hz
Dimensions 270 x 246 x 174 mm
Weight about 6 kg
PWPN-1
[current source]
22
PURPOSE
Current source type PWPN-1 is designated for checking current transformer load, measuring sensitivity of current
protection devices etc.
DESCRIPTION
Device PWPN-1 generates sinusoidal current or voltage with
power frequency and controlled amplitude. It is equipped with
ammeter/voltmeter.
User can choose generated and measured variable (current or
voltage) by two-position switch, selected variable is indicated
by LED (A or V).
23
24
RL-64D
[telecontrol device]
Delay of command transmission
- standard output
- power output
2,2/4,2 ms + time filter, standard output; single/multi
4,0/6,0 ms + time filter, power output; single/multi
Delay of continuous digital transmission 0,4 ms
Number of command signals 4 up to 20, possibility of continuous command transmission
Voltage ranges on command input 24 V, 60 V, 120 V, 250 V DC, configurable command input voltage threshold 70% Un
Command output:
- standard
- power
electromechanical relay: 1000 V, 100 W switched current 1 A, continuous current 2,5 A, switching time 1 ms
electromechanical relay: 7500 V, 50 W switched current 3 A, continuous current 5 A, switching time 3 ms
Linear interface
- electrical
- optical
E1 2 Mbit/s acc. to G.703.6, symmetrical out/input 120 or X.21 nx64 kbit/s
2 Mbit/s, singlemod., operation in II or III aperture, distance 20 up to 120 km
Option: 2 optical interfaces
Linear canal connection time < 5 ms
Output signal Frame acc. to ITU-T G.704; linear code HDB3
Substation digital interface
V.24 asynchronous 19,2 bit/s;
V.24 synchronous nx64 kbit/s;
V.35 nx64 kbit/s; X.21 nx64 kbit/s
Supervising interface - local / remote USB, RS232 / Ethernet 10/100 BaseT, protocol SNMP
Capacity of events log
Time resolution
1000 events, with time stamp
1 ms, with time sync between co-operating part of device
Time sync in device Ethernet 10/100 BaseT, protocol SNTP in LAN network or GPS protocol NMEA
Available telecommunication services
Digital communication with interface asynchronous RS232, synchronous V.24, X.21, V.35; telephone ana-
logue interface with E&M signalling, analogue telephone channels (POTS),
Cabinet for 48 commands/20 commands cassette 3U / 6U
Operation temperature 0 C 45 C
Power supply 230 V, 50 Hz or 220 V DC, 40 VA
Dimensions 3U 483 x 133 x 298 mm
Weight 5,5 kg
MND-26
[switch contacts anticoincidence meter]
26
Time measurement range up to 23 s
Resolution 0,1; 0,2; 0,5; 1,0 ms
Allowable uncertainty (0,01 % of reading + 1 digit)
Number of measuring contacts 6
Memory 90 measurements
Number of inputs "START" 2
Triggering voltage (external start) 110 220 V AC / DC
Switch coil control 2 control outputs
Switch-off coils control voltage (internal start) 48 220 V DC
Analogue channels 3, current
Measuring range in analogue channels -5 A +5 A
Operation temperature: meter/printer 5 C +40 C / + 5 C +35 C
Enclosure protection IP 67
Power supply 230 V, 50 Hz + internal battery
Dimensions 500 x 390 x 190 mm
Weight about 11 kg
PURPOSE
Switch contacts anticoincidence meter MND-26 is designated for simultaneous measurement of open and close times up
to 6 switch contacts, what enables determination of their operation anticoincidence.
This meter allows analogue signals recording (e.g. currents in switching on and off coils and arming current).
DESCRIPTION
Meter MND-26 is microprocessor-based mobile device for
switch contacts anticoincidence determination in cycles:
W, Z, WZ, ZW, WZW, with taking into account arming time
too. Measurement can be started internally it performs
automatically in predetermined time, or it can be initiated
by external voltage signal 110 220 V AC/DC. It is possible
to start measurement by changing state of one contact (only
anticoincidence measurement, but without necessity of voltage
control of switch).
The results are stored in memory and displayed on LCD screen.
It is possible to print results on internal printer (Kafka type) and
send them to computer or pendrive, using USB interface.
Duration of contacts vibration can be read from printed copy or
from recorded time diagram, using computer software. During
time and current measurements, voltage of switch coils supply
is measured too.
Meter with printer is placed in suitcase and can be supplied
from internal battery. Charging device is built in meter, printer
is optional accessory.
27
Output current regulation range
for WPS-300
for WPS-600
20 380 A
20 600 A
Time of current forcing
for WPS-300
for WPS-600
2 255 s
2 15 s
Max. output power 1,5 kW
Voltage measurement resolution 0,1 mV
Current setting resolution 2 A
Current ripples < 1 %
Operation temperature -5 C +40 C
Power supply 230 V, 50 Hz
Dimensions:
WPS-300
WPS-600
320 x 360 x 240 mm
524 x 428 x 220 mm
Weight:
WPS-300
WPS-600
about 18 kg
about 26 kg
WPS-300/600
[DC current source]
28
PURPOSE
Device provides measurement of contact resistance in switches, resistance of electric connections and other tests which
request high current intensity.
DESCRIPTION
There are 2 versions of DC current source: WPS-300 and
WPS-600, that differ in current range and forcing time.
Device consist of pulse power supply, microprocessor-based
controller and LCD display.
Output current and voltage drop on external circuit are measured
every second. These values and calculated resistance value are
directly displayed on LCD screen, recorded in device memory,
and can be transmitted to PC computer using RS-232 interface.
Output parameters values can be set by device keyboard.
29
Output voltage regulation range 0 260 V
Output current range max 2,5 A
Operation temperature -5 C +40 C
Power supply 230 V, 50 Hz
Dimensions 280 x 200 x 180 mm
Weight about 3 kg
ZCW-1
[power supply for switchs coils]
30
PURPOSE
Power supply for switch coils is designated for switches operation testing with reduced and elevated supply voltage.
DESCRIPTION
After switching on, on device display appears last voltage
setting. Change of output voltage is performed by keys or .
By pushing MENU button, options: GENERATION TIME, VOLT.
INCREASE, VOLT. DECREASE are available, user can choose
option using keys and . Using MENU button and keys ,
user can set new values. By pressing MENU once again, new
values are stored, ESC key abandon settings.
Button START/STOP begins/stops voltage generation. During
generation, changes in MENU options are not possible.
If voltage setting is displayed, user can activate automatics
mode A by pushing ESC button. In A mode, user can change
voltage (using or ) by percentage step value (according to
settings in options VOLT.INCREASE, VOLT.DECREASE). Value of
changed voltage and percentage change of rated voltage are
displayed on LCD screen.
TIME GENERATION option allows setting of continuous operation
or stop generation after determined period (1 s to 60 s).
Power supply is protected against overload current (>2,5 A) by
generation switch off (LED signalling >I).
31
Output power 3,5 kVA
Output voltage 100, 200, 400 V AC
Current regulation smooth up to 50 A AC
Allowable uncertainty (0,2 % of reading + 2 digits)
Operation temperature -5 C +40 C
Enclosure protection IP 42
Power supply 230 V, 50 Hz
Dimensions 530 x 430 x 210 mm
Weight about 50 kg
ZNR-1
[electrocution voltage selector]
32
PURPOSE
Electrocution voltage selectors are used for forcing measurement current in tested earth electrode system, during touch
and step voltage measurements. Voltage selector and electrocution voltage meter MNR-1, which provides touch and step
voltage measurements, form complete set for earth system testing.
DESCRIPTION
ZNR-1 is current source of rated power 3.5 kVA, which generates
alternating current up to 50 A, with arbitrary long time.
Selector is equipped with digital ammeter and voltmeter for
output parameter measurements.
High value of current enables obtaining measuring voltages
higher than noise voltage level and achievement of required
measurement accuracy.
When measuring circuit resistance is high, one can use two
additional output voltage ranges:
- 200 V AC and current up to 18 A,
- 400 V AC and current up to 9 A.
Version with output voltage 1000 V is available on special
request.
33
34
Output power 7,5 kVA
Output voltage 150, 300 V AC
Current regulation smooth up to 60 A AC
Allowable uncertainty (0,2 % of reading + 2 digits)
Operation temperature -5 C +40 C
Power supply 230 V or 400 V, 50 Hz
Dimensions 465 x 660 x 880 mm
Weight about 75 kg
ZNR-2
[electrocution voltage selector]
PURPOSE
Electrocution voltage selectors are used for forcing measurement current in tested earth electrode system, during touch and
step voltage measurements, on soils with decreased conductivity (rocks, sands). Voltage selector and electrocution voltage
meter MNR-1, which provides touch and step voltage measurements, form complete set for earth system testing.
DESCRIPTION
ZNR-2 is current source of rated power 7.5 kVA, which generates
alternating current up to 60 A, with arbitrary long time.
Selector is equipped with digital ammeter and voltmeter for
output values measurements.
High value of current enables obtaining measuring voltages
higher than noise voltage level and achieving of required
measurement accuracy.
Two ranges of output voltage and changeable polarity
considerable extend its usability.
Modular-designed device is placed on hand truck, which
enables easy transportation and movement.
35
MNR-1
[electrocution voltage meter]]
Voltage measurement range 100 mV 100 V, 50 Hz
Accuracy class 1,5
Input resistance about 300 k
Resistor shunts 1000 , 1500 , 3000
Signalling range 20 100 % of voltage range
Power supply
internal Cd-Ni battery
(with possibility of charging from
internal supply)
Dimensions 450 x 350 x 120 mm
Weight about 5 kg
36
DESCRIPTION
Electrocution voltage measurement is performed by measuring
probes set and mobile meter, with possibility of selecting
proper range and input resistance. The result of measurement
is presented on indicating instrument.
The measuring set consists of suitcase with electrocution
voltage meter, measuring cables, power supply cable for
battery charging and probes: 2 plate probes (280 x 140 mm)
for putting on ground and 2 flexible probes for hands.
37
PURPOSE
Meter is assigned for measurements of electrocution voltage, that occurs in power energy objects area, particularly near
earth systems and metal structures.
WP-100
[current source]
Load current Izn 0 100 A
Max. power 500 VA
Output voltage regulation range 0 250 V (for current 0,8 A)
Allowable uncertainty
of voltage measurement
(0,2 % of reading + 2 digits)
Allowable uncertainty
of current measurement
(0,2 % of reading + 2 digits)
Rated power consumption 600 VA
Operation temperature -5 C +40 C
Power supply 230 V, 50 Hz
Dimensions 475 x 357 x 176 mm
Weight about 25 kg
38
DESCRIPTION
WP-100 is assigned for continuous operation with current
range from 0 to In, and voltage range from 0 to 250 V. Current
circuit is isolated from power supply network. Voltage circuit
has galvanic connection with power supply network. Current
source has digital display for showing values of forced current,
voltage and time. Device is equipped with over current and
thermic safeguard, what protect it from overheating or failure.
Control of current source operation is provided by choose one
of 5 different operation modes.
39
PURPOSE
Source WP-100 is assigned for supply devices, which request checking and for regulations of circuits, dependent on current
value e.g. current transformers, over current relays etc.
40
Time measurement range 0 166 minutes
Max. temporary current 3000 A
Max. continuous current 1500 A
Max. source voltage 2500 V
Max. output power 3 kVA
Allowable uncertainty
of voltage measurement
(0,2 % of reading + 2 digits)
Allowable uncertainty
of current measurement
(0,5 % of reading + 5 digits)
Memory capacity 64 measurements
Operation temperature -5 C +40 C
Power supply 230 V, 50 Hz
Dimensions 400 x 880 x 610 mm
Weight 50 kg
WP-1000
[current source]
PURPOSE
Test set WP-1000 is overseen for measurements of instrument transformers and can be used for checking of overcurrent
relays and systems regulated by current or voltage, as well as protection automatics systems.
DESCRIPTION
Current source is multifunctional device using microprocessor
technology for controlling high power systems.
Current source provides AC 50 Hz current, regulated from
0 to 3000 A. Up to 1500 A the current is supplied by any time.
Above this value operating time is 3 s, 3000 A is generated by 1s.
Beside high current circuits current source is equipped with
regulated source 2500 V / 1 A and 500 V / 5 A for making
magnetization characteristics of instrument transformers 1 A
and 5 A. Maximum provided power is 3 kVA.
Test parameters as current ratio, ratio uncertainty, angle
uncertainty, total uncertainty and loading power can be
displayed on graphical display screen as measured or calculated
values or in the form of diagram of given value versus current
or voltage.
All measured or calculated values can be saved and displayed
on the screen or sent by RS 232 to computer. The power source
is delivered with software (Windows based) enabling taking
stored results from current source, their analysis, processing
and conversion to spreadsheet.
The software enables also transmission of some settings to
current source. The current source consists of two modules
mounted on hand truck.
Beside of current source WP-1000 is manufactured also version
WP-500 with lower output currents.
41
Rated load current Izn
0 4000 A
Max. power 10 kVA
Output voltage regulation range 0 400 V
Allowable uncertainty of voltage measurement (0,2% of reading + 2 digits)
Allowable uncertainty of current measurement (0,2% of reading + 2 digits)
Chronograph range 0,1 ms 100 h
Allowable uncertainty of chronograph measurement (0,01% of reading + 1 digit)
Operation temperature -5 C +40 C
Power supply 400 V, 50 Hz
Dimensions 550 x 660 x 1000 mm
Weight about 85 kg
WPu-4000
[current source]
42
PURPOSE
Current source WPu-400 has the highest power and output current in the series of current sources type WPu. It is portable
testing set designed for AC current supply of devices which need checking and regulation of systems depended on the level
of current or voltage e.g. thermal releases, current transformers, overcurrent releases, primary releases etc., and especially
for testing of releases in power switches type APU.
DESCRIPTION
Current source can generate currents up to several thousands
amperes and has got module structure equipped with control
panel, current source and hand truck enabling easy moving
and transport. If it is permitted by outer circuit, the current
source set can generate temporarily (15 s) 4200 A load.
The source is equipped with high current terminals,
supplying current from outputs 4000 A / 2,5 V or 100 A / 0,5 V
alternatively. Every source should be used separately.
43
Current regulation range I AC 0 300 A
Output voltage regulation range U AC 0 Uz (for current 4 A)
Current regulation range I DC 0 100 A
Milivoltmeter range DC 0 2000 mV
Max. sources power 800 VA for AC and 300W for DC
Allowable uncertainty
of AC / DC voltage and current measurement
(0,2 % of reading + 2 digits)
Rated power consumption 1000 VA
Operation temperature -5 C +40 C
Humidity up to 80 %
Enclosure protection
for special purpose II protection class
IP 67
Power supply Uz 230 V, 50 Hz
Dimensions 486 x 392 x 191mm
Weight about 27 kg
WPPS-300
[DC/AC current source]
44
PURPOSE
AC and DC Current Source type WPPS-300 is designed for checking and regulations of protection automatic devices supplied
with AC and DC current e.g. current transformers, overcurrent and voltage relays, releases thermal protection, switch
contacts etc. during start-up and periodical tests. It enables:
determination of instrument transformer ratio,
controlling and setting of protection automatics systems,
determination of release operating threshold,
determination of self-times of switches,
determination of resistance of switch main contacts.
DESCRIPTION
WPPS-300 is designed for continuous operation in full scale
regulation of all output circuits. Device is equipped with digital
readout of forced current, voltage and measured time. Digital
stop watch is controlled by changes of status obtained:
no-potentially or by any voltage signal. Current source is protected
from damage and has got resistant case with ABS.
For special demand the current source can be made in protection
class II, IP 67.
45
Max. power consumption about 650 VA
Max. power of current output IPRI 600 VA
Current regulation range IPRI 0 120 A
Current range ISEC 0 10 A
Voltage range USEC 0 100 V
Current source operation time IPRI for current up to 100 A continuous
Output voltage regulation range U for load current I 0 0,5 A 0 1000 V
Allowable uncertainty of current and voltage measurement (0,2 % of reading + 2 digits)
Chronograph range 0 100 h
Operation temperature -5 C +40 C
Humidity up to 80%
Power supply 230 V, 50 Hz
Dimensions 480 x 390 x 190 mm
Weight about 25 kg
TP-100
[current transformer testing device]
32 46
PURPOSE
Instrument transformer tester TP-100 is designed for checking of instrument transformers operating in semi-indirect and
indirect systems used for making energy accounts. Checking should be done in the case of:
carrying out acceptance, start-up, service and post-accident tests,
when instrument transformer is damaged or verification marks are damaged or when both sides find erroneous
indications or when the correct ratio is unknown (lack of rating plates).
Besides, tester can be used for checking and regulation of protection automatics components supplied from AC voltage
source, as switches, current and voltage relays, overcurrent and thermal releases etc.
DESCRIPTION
Instrument transformer tester enables:
determination of angle uncertainty, current and real ratio
and load of instrument transformer secondary side,
determination and regulation of operation threshold in
current and voltage release of switch,
determi nati on of ti me-current characteri sti c of
overcurrent and thermal protection,
determination of self times of switches and contactors,
controlling and setting of other elements of protection
automatics depended on current and voltage value,
data archiving, analysis and transfer to computer.
47
Power Research and Testing Company
ENERGOPOMIAR-ELEKTRYKA Ltd.
PL 44-101 Gliwice, witokrzyska 2
tel. secretarys office: +48 32 237 66 03
fax: +48 32 231 08 70
e-mail: sekretariat@elektryka.com.pl
internet: www.elektryka.com.pl