SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications system is used in the lowest end of industrial data communication. Main areas of use are the connection of binary actuators and sensors. The Actuator-Sensor Interface is normed according to EN 50295 and is a manufacturer-independent bus system of the degree of protection IP67.
SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications system is used in the lowest end of industrial data communication. Main areas of use are the connection of binary actuators and sensors. The Actuator-Sensor Interface is normed according to EN 50295 and is a manufacturer-independent bus system of the degree of protection IP67.
SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications system is used in the lowest end of industrial data communication. Main areas of use are the connection of binary actuators and sensors. The Actuator-Sensor Interface is normed according to EN 50295 and is a manufacturer-independent bus system of the degree of protection IP67.
ST-PRO1 AS-i Communications System Page 1 Date: 24.06.2004 File: PRO1_A1E.1 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives AS-i Communications System Contents Page Area of Use and Basic Properties ................................................................................................. 2 AS-i Cables ...................................................................................................................................... 3 AS-i Modules ...................................................................................................................................... 4 Configuration .................................................................................................................................... 5 AddressingAS-i Slaves .................................................................................................................. 6 SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications System Page 2 Introduction The Actuator-Sensor Interface is used in the lowest end of industrial data communication. Main areas of use are the connection of binary actuators and sensors. The Actuator-Sensor Interface is normed according to EN 50295 and is a manufacturer-independent bus system of the degree of protection IP67. Properties Connectable system: binary inputs and outputs analog inputs and outputs Number of slaves: maximum of 62 Response time: <5ms Maximum length: 300 m Topologies: Point to Point topology Star topology Bus topology Transport medium: unshielded cable with 2 wires Bus principle: Master - Slave Date: 24.06.2004 File: PRO1_A1E.2 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives Area of Use and Basic Properties SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications System Page 3 Energy and Data AS-interface uses unshielded ribbon cable to transmit data and energy (IP67). This cable is yellow. Because of the transmission of data and energy on a two-wire cable, a special AS-i power pack with data isolation is required. Properties Due to the geometric design of the cable, the wires for +and can no longer be mixed up. The cable is self-healing. Slaves can be placed where ever you like. Auxiliary Power For power consumption over 8 amperes or for selective switch-off, such as, in emergency situations, an AC or DC auxiliary power can be laid in parallel through a cable of the same kind. Typically, a red cable is used for 230 VAC and a black cable is used for 24 VDC. Date: 24.06.2004 File: PRO1_A1E.3 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives AS-i Cable Geometrical ribbon cable Slave housing Contacts SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications System Page 4 DP/AS-i Link 20 The DP/AS-i Link 20 takes over the role of AS-i Master and is Profibus slave with regards to its connection to the SIMATIC S7 at the same time. Through communication processors (CP), the SIMATIC S7 could also be connected directly with the AS-i bus. Slaves Every AS-i slave has a unique bus address. You enter this bus address with the programming unit. Compact Modules Compact modules consist of two housing parts: the mounting plate (base module) and the attach module (communication unit). The mounting plate makes the connection with the yellow As-i cable and is snapped onto a commercial DIN mounting rail. The standard actuators and sensors are attached to the attach module with screw caps. There are atttach modules with up to a maximum of 4 inputs and 4 outputs each. Analog Modules The design of the analog modules is the same as for the compact modules. Analog modules can have a maximum of 2 channels. These can be 2 input or 2 output channels. Analog sensors are also connected with screw caps. Date: 24.06.2004 File: PRO1_A1E.4 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives AS-i Modules DP/AS-i Link 20 Analog Modules Compact Modules Power Supply AS-i Bus Profibus DP SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications System Page 5 Configuration The DP/ASI-i Link 20 is used in the hardware configuration like a standard Profibus slave. Addresses The DP/AS-i Link 20 is given a Profibus DP slave address, such as, the address 100. After that, 16 input bytes and 16 output bytes each are assigned. In the example, these are the addresses 24 to 39 for the inputs as well as for the outputs. Communication The Profibus master communicates with the DP/AS-i Link 20 as Profibus slave through the assigned input and output areas. The DP/AS-i Link 20 communicates independently as AS-i master with a maximum of 62 slaves. Date: 24.06.2004 File: PRO1_A1E.5 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives Configuration Profibus Slave AS-i Master SITRAIN Training for Automation and Drives ST-PRO1 AS-i Communications System Page 6 4 Bits per Slave For every slave, 4 bits for inputs and outputs are always reserved (see also above slide). Depending of the type of AS-i slave, all or some of the bits are needed for communication. . Date: 24.06.2004 File: PRO1_A1E.6 SIMATIC S7 Siemens AG 2004. All rights reserved. SITRAIN Training for Automation and Drives Addressing AS-i slaves 26.7 26.6 26.5 26.4 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 slave 2 slave 4 slave 6 slave 8 slave 10 slave 12 slave 14 slave 16 slave 18 slave 20 slave 22 slave 24 slave 26 slave 28 slave 30 slave 1 slave 3 slave 5 slave 7 slave 9 slave 11 slave 13 slave 15 slave 17 slave 19 slave 21 slave 23 slave 25 slave 27 slave 29 slave 31 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 slave 2 slave 4 slave 6 slave 8 slave 10 slave 12 slave 14 slave 16 slave 18 slave 20 slave 22 slave 24 slave 26 slave 28 slave 30 slave 1 slave 3 slave 5 slave 7 slave 9 slave 11 slave 13 slave 15 slave 17 slave 19 slave 21 slave 23 slave 25 slave 27 slave 29 slave 31 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 26.3 26.2 26.1 26.0