You are on page 1of 111

www.huawei.

com
Huawei confidential, 2007-10
Huawei GENEX Series
2
www.huawei.com
Huawei confidential, 2007-10
2
Objectives
Upon completion of this course,
you will be able to:
Master data collection method of
DT

Master how to use GENEX Probe
to collect drive test data
3
www.huawei.com
Huawei confidential, 2007-10
3
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data
Collection
Other Features
Case Study
4
www.huawei.com
Huawei confidential, 2007-10
4
RNC
GENEX U-Net
Radio Network Planning
Tool
Downlink + Uplink
GENEX Probe
GENEX Assistant
Test & Post-Process Tools
GENEX Nastar
Network Performance Analysis
System
GENEX U-Net is a radio
planning tool that fully supports
the technologies of GSM,GPRS-
EDGE, CDMA IS95,
WCDMA/UMTS/HSDPA/HSUPA,
CDMA 2000/1xRTT/1xEVDO, and
TD-SCDMA wireless networks.
The GENEX Probe, network
optimization and drive test data
collection system, is an air
interface test tool for
WCDMA/HSDPA/HSUPA/GSM/G
PRS networks.
GENEX Assistant is a
professional wireless test data
post-processing software system.
GENEX Nastar is a platform for
monitoring and optimizing the
performance of
GSM/CDMA/WCDMA wireless
networks
Huawei GENEX Family
5
www.huawei.com
Huawei confidential, 2007-10
5
Whole Flow
Overview
Radio Network Planning Tool
Air Interface Test Tool and
Post-Processing Tool
Network Performance Analysis
Tool
Make full use of 2G
resources
GENEX covers the
network lifecycle
6
www.huawei.com
Huawei confidential, 2007-10
6
GENEX Partners in The World
Applied in the Huawei 2G and 3G planning and
optimization projects
Covers more than forty countries, including
commercial and pilot offices
Assists the renowned operators in establishing and
optimizing the network with high quality.
The network operators include but not limited to:
China Mobile, China Unicom, China Telecom, China
Netcom, Vodafone, PBTL, T-Mobile, Orange, CellPlus,
PCCW(Sunday), Telecom, eMobile.
Aims at consistently providing the customers with
professional and high-level solutions for network planning
and optimization.
Employed by network operators and designing institutes
all over 26 provinces and municipalities
Integrates the experiences of renowned operators,
advancing with customers hand by hand.


7
www.huawei.com
Huawei confidential, 2007-10
7
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data
Collection
Other Features
Case Study
8
www.huawei.com
Huawei confidential, 2007-10
8
GENEX Probe drive test system
GARMIN Series
GPS
DTI Scanner
(Built-in GPS)
Anritsu
Scanner
Trimble Series
GPS
Qualcomm TM6250/
6275
AT Command
Supported
Mobile
Huawei
WCDMA/HSDPA Data
card
*Support WCDMA
1800/1900/2100M
Equipment
Composition

support multi UE
carry out different
tests
simultaneously
Physical connection
Equipment bag
easy to carry and
suitable to be used in
the car
Huawei Dual Mode
Mobile(U626/U636)
9
www.huawei.com
Huawei confidential, 2007-10
9
DT Operation Flow
1. Probe Installation. HSDPA test need Probe version 1.3 or above;
HSUPA test need Probe version 1.4 or above.
2. Plug Probe dongle.
3. Connect Hardware device to the laptop.
4. Hardware configuration.
5. System Configuration. Set Log mask.
6. Test Plan Configuration.
7. Import engineering parameters, open Map window and import the
related mapinfo file.
8. Open the parameter widows you want to observe, such as RSCP and
Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC
Message, NAS Message, etc.
9. Start Test, start recording.
10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically,
please "Start Test first, then start to make call test.
10
www.huawei.com
Huawei confidential, 2007-10
10
Probe
Parameter
observation
area
Control &
parameter
items

hardware &
system
configuration
HSDPA
parameters
HSUPA
parameters
RRC&NAS
Messages
Throughput
PS service
statistics
11
www.huawei.com
Huawei confidential, 2007-10
11
Hardware configuration
PS domain
test must set
Modem port.
Terminals in the following list can support HSDPA test are: Huawei
E620 data card , QUALCOMM TM6275 and QUALCOMM TM6280.
Huawei E220 and E6280 will support HSUPA soon.
Configuration Before Test
12
www.huawei.com
Huawei confidential, 2007-10
12
Logmask setting
We can make UE report the data we need through Logmask setting.
System Configuration Before Test
13
www.huawei.com
Huawei confidential, 2007-10
13
System Configuration Before Test
Event setting
We can define the event we need throuth Event setting.
14
www.huawei.com
Huawei confidential, 2007-10
14
System Configuration Before Test
Alarm setting
We can define the alarm event we need through Alarm setting.
15
www.huawei.com
Huawei confidential, 2007-10
15
System Configuration Before Test
Other setting
We can set the Time Record Mode for a Log Packet, GPS synchronization
Mode, DialUp Property for Data Service, Display Filter for Log Data, Replay
Mode for Event and Parameters for DTI Scanner which we need through
other setting.
16
www.huawei.com
Huawei confidential, 2007-10
16
Test Plan Configuration
Control each device's behavior by selecting Test Plan items and setting property
parameters of each test items. Set the Test Plan respectively for each device
(UE/Scanner).
Test Plan Configuration Before Test
1. Select
Test
Device
2. Add Test
Scenario
3. Add
Test Item
4. Set Test
Property
17
www.huawei.com
Huawei confidential, 2007-10
17
Set Test Plan for DTI Scanner
1. Select
Test Item
2. Set Item
Property
Test Plan Configuration Before Test
18
www.huawei.com
Huawei confidential, 2007-10
18
Set Test Plan for Anritsu Scanner
Test Plan Configuration Before Test
1. Select
Test Item
2. Set Test
Property
19
www.huawei.com
Huawei confidential, 2007-10
19
Set Test Plan for Anritsu Scanner
Cont.
Test Plan Configuration Before Test
Unspecified base station measurement
Set the common properties of test
Items in the unspecified base station measurement
20
www.huawei.com
Huawei confidential, 2007-10
20
Set Test Plan for Anritsu ScannerCont.
Test Plan Configuration Before Test
Unspecified base station measurement
Set the common properties of test
Items in the Conditions base station
21
www.huawei.com
Huawei confidential, 2007-10
21
Set Test Plan for Anritsu ScannerCont.
Test Plan Configuration Before Test
Unspecified base station measurement
Set the common properties of test
Items in the CH limits
22
www.huawei.com
Huawei confidential, 2007-10
22
Set Test Plan for Anritsu ScannerCont.
Test Plan Configuration Before Test
Unspecified base station measurement
Set the common properties of test
Elements in the MeasureChannel Dialog Box
23
www.huawei.com
Huawei confidential, 2007-10
23
Set Test Plan for Anritsu Scanner
Cont.
Test Plan Configuration Before Test
Specified base station measurement
Set the specified properties of test
24
www.huawei.com
Huawei confidential, 2007-10
24
Set Test Plan for UE
1. Voice call
Test Plan Configuration Before Test
Suggestion: When testing voice call, do not perform PS dialup on the Modem of
the outgoing UE manually. Otherwise, voice call maybe hangs up abnormally.
The UE that is performing PS services can serve as an incoming UE for Voice Call
or Video Phone test. Thus, the CS and PS concurrent test can be performed on the
same UE.
25
www.huawei.com
Huawei confidential, 2007-10
25
Test Plan Configuration Before Test
Parameters for Voice Call:
1.1 Call type
Continuous Call: The call continues if it does not fail, drop, or hang up. If the call
fails, drops, or hangs up, Probe waits for a call interval to originate another
call.
Call by Call: call: The call lasts and waits for the predetermined calling duration
and call interval, and repeats for the times defined in call count.
1.2 Setup time: the maximum time for call setup. If the call cannot be
setup within the defined period, the call setup fails.
1.3 Calling duration: the duration of one call, from call setup to call normal
release. (apply only to call by call)
1.4 Call interval: the time between two calls, from the previous call
disconnection to the beginning of the next call.
1.5 Exceptional Interval The interval between the exceptional end of a
call drop and the beginning of the next call.
1.6 Count Mode: the limitations on the call number -> Finite / Infinite.
26
www.huawei.com
Huawei confidential, 2007-10
26
Set Test Plan for UE
2. Video Phone
Test Plan Configuration Before Test
Suggestion: To conduct this test, the UE and the called terminal must support
the video calls.
27
www.huawei.com
Huawei confidential, 2007-10
27
Set Test Plan for UE
3. PING
Test Plan Configuration Before Test
Note: PING packet size have an effect on PING delay time. Usually, the PING
packet size is described in the criterion of the test project, set the parameter
according to the criterion. Otherwise we can use the default setting: 32 Bytes if
there is no special requirement.
28
www.huawei.com
Huawei confidential, 2007-10
28
Parameters for PING:
Test Plan Configuration Before Test
29
www.huawei.com
Huawei confidential, 2007-10
29
Set Test Plan for UE
4. Ftp Upload / Ftp Download
Test Plan Configuration Before Test
Note: PS connection can be set up by one FTP Download test item if
correct APN has been set in UE.
30
www.huawei.com
Huawei confidential, 2007-10
30
Parameters for Ftp Upload / Ftp
Download:
Test Plan Configuration Before Test
4.1 User, Password: FTP user name and password. For anonymous login,
also need to input anonymous as username.
4.2 Remote File: Destination file address, input the detailed download
path, such as, ftp://10.0.0.1/download/1.dat
4.3 Local File: Local path to save the download file, such as, C:\1.dat
4.4 MultiTask Count: When we use multi-threading download, set the
number of threads here.
4.5 Test Interval (sec): The time interval between multi downloads. After
finishing a download, wait for serveral time, then start another times
download.
4.6 FTP Count: the total number of ftp download test.
31
www.huawei.com
Huawei confidential, 2007-10
31
Parameters for Ftp Upload / Ftp
Download:
Test Plan Configuration Before Test
4.7 Disconnection Mode: the mode of Disconnection, there are three choices:
Keep Disconnected: Do not perform PDP context deactivation ( remain RRC
connection) after the target files are loaded completely, just wait for interval
time then continue next ftp download test.
Disconnect By Time: Perform PDP context deactivation periodically. The period
for the PDP context deactivation is represented by the Valid FTP Duration
parameter. If the target files are not loaded completely within the predefined
time, the loading result shows timeout. Probe considers this loading as failure
and initiates another PDP context deactivation in the next loading.
Disconnect After Transfer Complete: Each time when the file load is complete,
PDP context deactivation would be performed.
FTP Upload:
Parameters are the same with FTP downloads. Probe will upload the local
file to the destination path automatically.

Make sure you have the authority to upload file before test.
32
www.huawei.com
Huawei confidential, 2007-10
32
Set Test Plan for UE
5. HTTP
Test Plan Configuration Before Test
33
www.huawei.com
Huawei confidential, 2007-10
33
Parameters for HTTP:
5.1 URLRefers to the destination HTTP address of the server.
5.2 PortRefers to the HTTP serving port. By default, the value is 80.
5.3 Control ModeTest by time and Test by RRC state.
5.4 Test Interval Refers to the interval between two HTTP tests. This
parameter takes effect when Control Mode is Test by Count.
5.5 HTTP CountRefers to the total number of HTTP tests. This parameter
takes effect when Control Mode is Test by Count.
Test Plan Configuration Before Test
34
www.huawei.com
Huawei confidential, 2007-10
34
Set Test Plan for UE
6. PDP
Test Plan Configuration Before Test
NoteIf False is selected in Auto Dialup, the connections on the signaling plane
are set up. The signaling includes RRC signaling, PDP context activation request,
and PDP context activation receive message. The service plane, however, is not
established. In such a situation, the PING service is not being connected.
If True is selected, the connections on both signaling and service planes are
established. That is, the PC <-> UE <-> CN channel is set up for dialup connection
and providing services.
35
www.huawei.com
Huawei confidential, 2007-10
35
Parameters for PDP:
Test Plan Configuration Before Test
Auto Dialup: If the option is false, then only setup signaling plane
connection. In NAS Message window, we can see the Activate PDP
context request & Activate PDP context accept message, but we
cant perform service in this mode. If the option is true, then there
will setup a connection between PC<-->UE<-->CN, the same as PS
Dialup, we can perform service in this mode.
Reserved Duration: The period when the PDP is in active status, thus, it is
time from activate PDP context accept to deactivate PDP context
request.
Test Interval: If a PDP test is success, wait for Test Interval to do next PDP
test. Then, it is time from deactivate PDP context accept to activate
PDP context request.
Exceptional Interval: If a PDP test is failed, wait for Exceptional Interval
and then do next PDP Test.
UL/DL Max Rate (Kbps)
UL/DL Guaranteed Rate (Kbps)
36
www.huawei.com
Huawei confidential, 2007-10
36
Set Test Plan for UE
7. PS DaiUp / PS HangUp
Test Plan Configuration Before Test
The function of PS Dialup is
to setup a PS connection.
37
www.huawei.com
Huawei confidential, 2007-10
37
Parameters for PS Dialup:
Test Plan Configuration Before Test
7.1 APN: Access Point Name.
Ask the local PS domain engineer for the access point name. APN is named as
huawei.com or huawei.
7.2 QoS
Traffic Class
UL Max V(kbit/s)uplink max rate
DL Max V(kbit/s)downlink max rate
UL Guaranteed V(kbit/s)uplink guarantee bit rate
DL Guaranteed V(kbit/s)downlink guarantee bit rate
Note: For BE service, such as Background Class and Interactive Class, dont
set the UL & DL Guaranteed V.
The UMTS Specifications specify that BE service has no requirement on
guarantee bit rate. Setting guarantee bit rate may result in PS connection
setup failure for many mobiles do not support the setting.
38
www.huawei.com
Huawei confidential, 2007-10
38
Test Plan Configuration Before Test
Supplements about APN, QoS Setting
a) If leave APN, QoS parameters blank
Probe wont send the associated command to the UE if the parameters
mentioned above is not set, that is the UEs former setting will be maintained.
b) Methods for setting APNQoS and their correlationship
1) Set by AT command in MODEM initial command
2) Set by Probe in Test Plan

When both Probe and MODEM have APN and QoS information, because AT
command in MODEM initial command is send to UE more closely before PS
connection setup, it will replace the information send to UE by Probe. That is
Probes setting doesnt work if AT command also exists in the MODEM initial
command.
39
www.huawei.com
Huawei confidential, 2007-10
39
Set Test Plan for UE
8. SMS
Test Plan Configuration Before Test
40
www.huawei.com
Huawei confidential, 2007-10
40
Parameters for SMS:
8.1 Service Center Numberthe number of the short message service
center
8.2 MessageThe short message content
8.3 Destination NumberThe destination number of the short message
service
8.4 Test CountThe total number of the cyclic sending
8.5 Test IntervalInterval between two short messages.
Test Plan Configuration Before Test
41
www.huawei.com
Huawei confidential, 2007-10
41
Set Test Plan for UE
9. Video Streaming
Test Plan Configuration Before Test
42
www.huawei.com
Huawei confidential, 2007-10
42
Parameters for Video Streaming:
9.1 URLRefers to the URL address of the destination file, for example,
tsp://192.168.34.154/athens/wuhuan.rm
9.2 Test Countthe number of the cyclic plays.
Test Plan Configuration Before Test
43
www.huawei.com
Huawei confidential, 2007-10
43
Set Test Plan for UE
10. Multi-RAB
Test Plan Configuration Before Test
Note: The Multi-RAB test supports PS and CS concurrent service tests. In
addition, this test provides the solution to the problem of failing to stop
AMR automatic test for the same mobile phone when the dialup connection
of data service is set up.
44
www.huawei.com
Huawei confidential, 2007-10
44
Parameters for Multi-RAB:
10.1 Concurrent TypeThe type of a concurrent test
10.2 Startup PriorityThe sequence of sub-services in concurrent tests
10.3 FTP TypeFTP Upload / FTP Download
10.4 End TypeBy Time / By File
10.5 Test CountThe counts of test
10.6 Test IntervalThe interval between two tests
10.7 FTP Retry Countthe maximum retry times after the FTP connection
fails
Test Plan Configuration Before Test
45
www.huawei.com
Huawei confidential, 2007-10
45
Parameters for Multi-RAB
Cont.:
10.8 FTP Timethe time for one FTP transmission ; This parameter
takes effect when End Type is set By Time
10.9 CS and Ftp Intervalthe period between initiation of a call and
execution of FTP service
10.10 Traffic ClassBackgroundConversationalInteractive
StreamingSubscribed
10.11 UL / DL Max Rate (Kbps)
10.12 UL / DL Max Guaranteed Rate (Kbps).
Test Plan Configuration Before Test
46
www.huawei.com
Huawei confidential, 2007-10
46
Set Test Plan for UE
11. Key-Emul

Test Plan Configuration Before Test
NoteNot all functions of a mobile phone can be tested by executing
commands. For the functions such as VP calling, MMS, and E-Mail, you can
conduct automatic dialing test through the key emulation.
47
www.huawei.com
Huawei confidential, 2007-10
47
Parameters for Key-Emul:
11.1 Key Emulation List
11.2 Test Interval
11.3 Test Count

Test Plan Configuration Before Test
48
www.huawei.com
Huawei confidential, 2007-10
48
Parameters for Key-Emul
Cont.:
Test Plan Configuration Before Test
49
www.huawei.com
Huawei confidential, 2007-10
49
Parameters for Key-Emul
Cont.:
Test Plan Configuration Before Test
50
www.huawei.com
Huawei confidential, 2007-10
50
Set Test Plan for UE
12. Wait

Test Plan Configuration Before Test
NoteThe Wait test is used to set the time interval between two test
items.
51
www.huawei.com
Huawei confidential, 2007-10
51
Set Test Plan for UE
13. AT Control

Test Plan Configuration Before Test
NoteTest the AT commands on each UE before the AT control test,
because the AT commands and their formats supported by different
vendor differ in many ways.
52
www.huawei.com
Huawei confidential, 2007-10
52
Parameters for AT Control:
13.1 Test CountThe number of the test
13.2 Command EditionRight-click the button on the right side to set the
test commands in the AT Command Edit dialog box, can set test
groups and add test commands for each test group.
Test Plan Configuration Before Test
53
www.huawei.com
Huawei confidential, 2007-10
53
Parameters for AT Control
Cont.:
Test Plan Configuration Before Test
54
www.huawei.com
Huawei confidential, 2007-10
54
Set Test Plan for UE
14. Stop Test

Test Plan Configuration Before Test
Finish the
test
55
www.huawei.com
Huawei confidential, 2007-10
55


Common used windows for HSDPA & R99
1. Serving, Active Set & Neighboring Cells
Parameter Window
Display PSC, RSCP, Ec/Io for
active set, monitor set and
detective set
In the figure, rectangle legend
implicates active set data, circle
implicates monitor set data, and
triangle implicates detected set
data. The data of the same type is
distinguished from each other
with different colors. Move the
mouse to a place to get the
scrambling code of the current
point.
When the UE is in idle state, PSC
in active set is about the cell
where the UE resides.
56
www.huawei.com
Huawei confidential, 2007-10
56


Common used windows for HSDPA & R99
2. Power Control
Parameter Window
DL SIR, SIR
Target
Rx: UE received
power;
Tx: UE tx power
UL/DL transmit
power control
57
www.huawei.com
Huawei confidential, 2007-10
57


Common used windows for HSDPA & R99
3. WCDMA BLER
Parameter Window
Displays BLER of different
transport channels.

In HSDPA connection
mode, A-DPCH's DL BLER is
being displayed.
58
www.huawei.com
Huawei confidential, 2007-10
58


MAC/RLC Messages
The MAC/RLC Messages window displays the messages about Media Access
Control (MAC) and Radio Link Control (RLC). The messages are visible only
when the associated items in LogMask are selected.
Parameter Window
59
www.huawei.com
Huawei confidential, 2007-10
59


RRC Messages
All the UEs or single UE are displayed on the window. The messages
selected on the left navigation tree are displayed. The detailed information
is displayed by double-clicking on the message.
Parameter Window
60
www.huawei.com
Huawei confidential, 2007-10
60
GSM RR Messages
The GSM RR Messages window displays GSM radio resource messages.
You can observe GSM RR Messages when UE is in GSM mode.
Parameter Window
61
www.huawei.com
Huawei confidential, 2007-10
61

NAS Messages
Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages
are displayed here as follow:
Parameter Window
62
www.huawei.com
Huawei confidential, 2007-10
62
App Throughput
Display both UL and DL application layer data rate, NAS rate and TCP
retransmission rate.
Parameter Window
63
www.huawei.com
Huawei confidential, 2007-10
63
RLC Throughput
Display both UL and DL RLC layer throughput, UL PDU retransmission
ratio and DL PDU error ratio.
Parameter Window
64
www.huawei.com
Huawei confidential, 2007-10
64
PING Service Quality Evaluation
The PING Service Quality Evaluation window displays the associated
indicators on the user plane of the PING service which includes PING
time, QoS, etc.
Service statistics Chart
65
www.huawei.com
Huawei confidential, 2007-10
65
PS Common Indicators
Including attach success rate, attach time, PDP activation success
rate, PDP activation time are displayed here.
Service statistics Chart
66
www.huawei.com
Huawei confidential, 2007-10
66
FTP Service Quality Evaluation
Displays the associated indicators on the user plane of the FTP service,
including Login time, download time, download rate, etc.
Service statistics Chart
67
www.huawei.com
Huawei confidential, 2007-10
67
HTTP Service Quality Evaluation
Displays the associated indicators on the user plane of the HTTP service,
such as page access time, page download time and page down load rate,
etc.
Service statistics Chart
68
www.huawei.com
Huawei confidential, 2007-10
68
Contents
GENEX Overview
GENEX Probe General workflow
Using Probe for HSDPA / HSUPA DT data
collection
Other Features
Case Study
69
www.huawei.com
Huawei confidential, 2007-10
69


HSDPA Parameters window
1. HSDPA Physical Channel Window
Parameter Window
70
www.huawei.com
Huawei confidential, 2007-10
70


HSDPA Parameters window
1. HSDPA Physical Channel Window (cont.)
Parameter Window
71
www.huawei.com
Huawei confidential, 2007-10
71


HSDPA Parameters window
2. HSDPA Decoding Statistics
Parameter Window
72
www.huawei.com
Huawei confidential, 2007-10
72

HSDPA Parameters window
3. HSDPA Link Statistic
Parameter Window
73
www.huawei.com
Huawei confidential, 2007-10
73

HSDPA Parameters window
3. HSDPA Link Statistic (cont.)
Parameter Window
Item Description
Scheduled Rate-Delta Instantaneous rate that the MAC layer schedules
Scheduled Rate-
Average
Average rate that the MAC layer schedules
Served Rate-Delta
Instantaneous rate at which the MAC layer transmits.
The transmission here includes Transmission failure and Re-
transmission
Served Rate-Average
Average rate at which the MAC layer transmits.
The transmission here includes: Transmission failure and Re-
transmission
MAC Layer Rate-Delta
Instantaneous rate at which the MAC layer transmits.
The transmission here excludes: Transmission failure and Re-
transmission
MAC Layer Rate-
Average
Average rate at which the MAC layer transmits.
The transmission here excludes: Transmission failure and Re-
transmission
HS-SCCH Success Rate-
Delta
Instantaneous success rate of the HS-SCCH channel
HS-SCCH Success Rate-
Average
Average success rate of the HS-SCCH channel
74
www.huawei.com
Huawei confidential, 2007-10
74

HSDPA Parameters window
3. HSDPA Link Statistic (cont.)
Parameter Window
75
www.huawei.com
Huawei confidential, 2007-10
75
Supplement for HSDPA Link Statistic:
Parameter Window
1. Delta vs Average
Delta is the average value in 200ms.

Average is the average value from the beginning of stat. to the current time. You can choose
to clear the former stat. data. The values displayed by Assistant are all belong to Delta series.

2. Parameters about rate
Scheduled Rate = The total block size scheduled to the UE during stat. time / (Total time slot
scheduled to the UE * 2ms)

Served Rate = The total block size scheduled to the UE during stat. time / stat. time length

HS-SCCH Success Rate = time slot number scheduled to the UE during stat. time / total time
slot number during stat. time

When multi UEs share a HS-SCCH channel, they will share channel resource. So, HS-SCCH
Success Rate reflects the time ratio of a UE occupies HSDPA resource. The closer to 100% of
total HS-SCCH Success Rate from UEs who share a HS-SCCH channel, the better schedule
performance the system has.

Served Rate = Scheduled Rate * HS-SCCH Success Rate
Mac Layer Rate = Served Rate * (1- SBLER)
76
www.huawei.com
Huawei confidential, 2007-10
76
Supplement for HSDPA Link Statistic:
Parameter Window
3. IBLER, SBLER vs Res.BLER

IBLER is 1st MAC-hs error block /total 1st MAC-hs transmission blocks.
IBLER Target can be configured on NodeB. And its statistic value in Probe
is 1st SBLER in HSDPA Decoding Statistic Window.

SBLER is MAC-hs error block / total MAC-hs transmission blocks, IBLER
target configured on NodeB have an effect on SBLER, now the common
value range of SBLER is 10%~15%.

Res.BLER means remain BLER, which is within RLC layer. One transmission
block only after multi-times unsuccessful MAC-hs retransmission, will be
calculated as RLC layer error block, stat. to Res.BLER. Res.BLER is
approximate to 0 in normal instance.
77
www.huawei.com
Huawei confidential, 2007-10
77
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration
78
www.huawei.com
Huawei confidential, 2007-10
78
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
79
www.huawei.com
Huawei confidential, 2007-10
79
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
80
www.huawei.com
Huawei confidential, 2007-10
80
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
81
www.huawei.com
Huawei confidential, 2007-10
81
HSUPA Parameter Window
2. HSUPA UL Channel Configuration
Parameter Window
82
www.huawei.com
Huawei confidential, 2007-10
82
Parameter Window
HSUPA Parameter Window
3. HSUPA Link Statistics
83
www.huawei.com
Huawei confidential, 2007-10
83
HSUPA Parameter Window
3. HSUPA Link StatisticsCont.
Parameter Window
84
www.huawei.com
Huawei confidential, 2007-10
84
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data
Collection
Other Features
Case Study
85
www.huawei.com
Huawei confidential, 2007-10
85
2G/3G re-selection and handover test
WCDMA
window
Synchronous decoding of 2G/3G
messages
2G/3G power information and cell
information
Events can be displayed in various
modes
2G/3G re-selection and handover
test
GSM window
Customized
window
Check handover time
in event window
86
www.huawei.com
Huawei confidential, 2007-10
86
Scanner test
Top N Pilot test
Top N pilot test
Specified pilot test
Spectrum analysis
Multi-frequency scanning
Multi-path signal analysis
CW test
Professional Scanner test
Spectrum test
Multi-path signal
analysis
Multi-
frequency test
87
www.huawei.com
Huawei confidential, 2007-10
87
Walking test
Indoor test
Support indoor test
Vertical test
Walking test
Automatic
Manual
Vertical test
88
www.huawei.com
Huawei confidential, 2007-10
88
Rich and comprehensive predefined
events, for example, call setup, call
drop, handover and so on
Data service analysis events
2G/3G handover events
Events displayed on graphs and maps
Co-Activation of event, signaling data
and measurement data facilitates
problem location
Customized event icons and alert
tones
Events auto-detection
Handover
Complete
Attention!
Call Drop!!
89
www.huawei.com
Huawei confidential, 2007-10
89
Loading log files as a
navigation of test
Multi-layers display on map,
and user can set offset to any
one
Supports SC reuse scene
Friendly interface of drive-testing
Layer offset
Enhanced map display
Event and track preview
90
www.huawei.com
Huawei confidential, 2007-10
90
Project Template
Project Template
Site Verification
Optimize
Benchmark
Acceptance
Customize
The Probe supports customizing and
loading project templates. All the
project templates are stored in the
sub-folder of the Template Project
folder. When the Probe is being
installed, the following default folders
of different categories are generated.
You can also set custom project
templates and save them in the
directory. When multiple tests with a
similar function are being performed,
you can directly open the
corresponding project template but
need not carry out repeated project
settings.
91
www.huawei.com
Huawei confidential, 2007-10
91
Log file replay
1. Parameter Window layout
2. Open log file
3. Set play speed
4. Play log file
Route and event preview
Logfile playing, multi-window co-activation
5. Locate event
92
www.huawei.com
Huawei confidential, 2007-10
92
Basic procedure of Probe data export
Export Data
1. select Export data 2. select target
format
3. set source file,
destination file and data
range
4. select device and
Log item to export
5. start export
Bin
Text
QXDM (Qualcomm data format)
Excel
Data Format
* Exported data used for post-processing of CW
Measurements data, data geographic binning
and filter.
93
www.huawei.com
Huawei confidential, 2007-10
93
Setting an Auto View
Setting an Auto View Funtion
You can open the configured window or page by selecting a button on the
toolbar.
94
www.huawei.com
Huawei confidential, 2007-10
94
The Auto View Config dialog box consists of five tab pages that share the
Auto open and arrange control. If you select the Auto open and arrange
check box, the system creates the configured page and the page view
configured in the page after the auto view is configured.
UE Common
UE Overview
UE Service Stat.
DTI Scanner
Anritsu Scanner

Setting an Auto View
Setting an Auto View Funtion
95
www.huawei.com
Huawei confidential, 2007-10
95
Setting an Auto View
UE Common
1. Page Name
Default
Setting:
Messages
2. Page View
Select the
needed View
Window.
96
www.huawei.com
Huawei confidential, 2007-10
96
Setting an Auto View
UE Overview
1. Set the view
and page
name for every
UE under test
on this tab.
This type of
view is
irrespective of
the test plan
configuration.

97
www.huawei.com
Huawei confidential, 2007-10
97
Setting an Auto View
UE Service Stat.
98
www.huawei.com
Huawei confidential, 2007-10
98
Setting an Auto View
UE Service Stat.
99
www.huawei.com
Huawei confidential, 2007-10
99
DTI Scanner
Page Name:
Default Setting is
DTI Pilot scan;
Every test Item
has a default
View.
Setting an Auto View
100
www.huawei.com
Huawei confidential, 2007-10
100
Anritsu Scanner
1. You can set the
view and page
name for testing
Anritsu Scanner on
this tab. This type
of view is
irrespective of the
test plan
configuration.
2. By default, the
Page Name is set
to Anritsu Pilot
scan and each test
item has its
corresponding
view.

Setting an Auto View
101
www.huawei.com
Huawei confidential, 2007-10
101
Convenient View
On the left of the soft, include five Page: ProjectControlConfiguration
View
Property.
Navigation View
102
www.huawei.com
Huawei confidential, 2007-10
102
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data
Collection
Other Features
Case Study
103
www.huawei.com
Huawei confidential, 2007-10
103
Contents
Case1. Inter-RAT handover test

Case2. WCDMA inter-frequency handover test

Case3. Multi-frequency Scanning
104
www.huawei.com
Huawei confidential, 2007-10
104
Case1. Inter-RAT handover test
Inter-RAT handover test
Event observation Location of handover
point
105
www.huawei.com
Huawei confidential, 2007-10
105
Case1. Inter-RAT handover test
Messages and measurement
from different networks
Inter-RAT handover
Time of Handover
signaling
106
www.huawei.com
Huawei confidential, 2007-10
106
Case2. WCDMA inter-frequency handover
test
The signal frequency
in active set is 2137.40
when the test starts
WCDMA inter-frequency handover
Log file:
Signaling window
107
www.huawei.com
Huawei confidential, 2007-10
107
Case2. WCDMA inter-frequency handover
test
Signaling
observation
before handover
WCDMA inter-frequency handover process
108
www.huawei.com
Huawei confidential, 2007-10
108
Case2. WCDMA inter-frequency handover
test
Observe it again, and the
frequency handover to
2132.40
WCDMA inter-frequency handover process
109
www.huawei.com
Huawei confidential, 2007-10
109
Case3. Multi-frequency Scanning
1. Set multi-frequency
Simultaneous scanning of multi-
frequency
2. Scanned multi-
frequency
3. Select specified
frequency to observe it
110
www.huawei.com
Huawei confidential, 2007-10
110
Case3. Multi-frequency Scanning
Simultaneous
observation of different
frequencies
Simultaneous scanning of multi-
frequency
www.huawei.com
Huawei confidential, 2007-10

You might also like