Professional Documents
Culture Documents
MCTCL221
ThisFireAlarmSystemTrainerisspeciallydevelopedtoteachandtrainstudentstoknowthefunctionandoperationofafirealarmsystem.
Thepurposeofafirealarmsystemistogivewarningwhenitdetectsanysignofapossiblefireoutbreakinanenclosedenvironment.The
equipmentconsistsofaControlPanel,Siren,Bell,SmokeDetector,HeatDetector,GlassBreak,StrobeLight,EmergencyStopandDuty
Pump.Itsdesignisbasedonpanelsystem.Eachpanelissilkscreenedwithsymbolsorblockdiagram.
Thecontrolpanelcomesin2to30zonesasstandardbutmorezonescapacitycanbemadetomeetwiththecustomer'sspecifications.It
acceptsawidevarietyofdetectorsandsoundingdeviceswithlinesupervisionoutputforthezoneandalarmbellcircuits.
SPECIFICATIONS
ControlPanel
Thepanelisinmodulardesignutilizinghighlyintegrated
modulestoprovideimprovedversatilityandeasyof
maintenanceandreplacement.Connectionsbetweenmodules
areestablishedwithhighlyreliablecomputerribboncablesand
removablesockets.
MAINSUPPLY
Dimension:100x298x50mm
Input/output:240VAC
LINKFORCONTROLPANEL
Dimension:200x298x50mm
InputVoltage:240VAC
VOLTAGESUPPLY
Dimension:200x298x50mm
Input:240VAC
Output:240VAC/24VDC
GLASSBREAK
Dimension:200x298x50mm
OperatingVoltage:24VDC
Contact:NormallyOpen
EMERGENCYSTOP
Dimension:100x298x50mm
OperatingVoltage:24VDC
Contact:NormallyClose
SECONDARYPUMP
SIMULATION
Dimension:100x298x50mm
OperatingVoltage:24VDC
FIREALARMSYSTEMTRAINER
MCTCL221
HEATDETECTOR
Dimension:100x298x50mm
OperatingVoltage:24VDC
Contact:NormallyOpen
BELL
Dimension:200x298x50mm
OperatingVoltage:24VDC
SMOKEDETECTOR
Dimension:200x298x50mm
OperatingVoltage:24VDC
STROKELIGHT
Dimension:100x298x50mm
OperatingVoltage:24VDC
ZONEDIAGRAM
Dimension:200x298x50mm
OperatingVoltage:24VDC
DUTYPUMP
Dimension:100x298x50mm
OperatingVoltage:240VAC24
VDC
GASDETECTOR
Dimension:200x298x50mm
OperatingVoltage:24VDC
WATERDETECTOR
Dimension:100x298x50mm
OperatingVoltage:24VDC
ELECTORMECHANICALSIREN
Dimension:100x298x50mm
OperatingVoltage:24VDC
STROBELIGHT
Dimension:100x298x50mm
OperatingVoltage:24VDC
DUTYPUMPCONTROLLER
Dimension:160x120x80mm
OperatingVoltage:240VAC
Description:Torun&stopdutypump
FIREALARMSYSTEMTRAINER
MCTCL221
ConventionalFireAlarmSystem
Estimatedlabtime:40hours
12WorkOrders
1SketchandWiring(1):Drawaschematicdiagram,andwireaprojectinvolvingfourcomponentsatagivenlocation.
2SketchandWiring(2):RedothecircuitofWorkOrder1withthecomponentsatadifferentlocation.
4Sketch,Wiring,andProgramming(1)1:Drawtheschematicdiagramofacircuitconsistingofabreakglass,heatdetector.
5Sketch,Wiring,andProgramming(2):Drawtheschematicdiagramofacircuitconsistingofasmokedetector,breakglass,siren,and
strobelight.
6Sketch,Wiring,andProgramming(3):Drawtheschematicdiagramofacircuitconsistingofapullstationinonezoneandabreakglass
stationinasecondzonetotriggerasireninathirdzone.
7Sketch,Wiring,andProgramming(4):Drawtheschematicdiagramofacircuitconsistingoftwopullstationsandaheatdetectorina
detectionzone,athirdpullstationinaseconddetectionzonetotriggerasiren,andastrobelightinasignalingzone.
8Sketch,Wiring,andProgramming(5):Drawtheschematicdiagramofacircuitconsistingofasmokedetectorindetectionzone1,a
strobelightindetectionzone2,apullstationinsignalingzone1,andastrobelightinsignalingzone2.
9Sketch,Wiring,andProgramming(6):Drawtheschematicdiagramofacircuitconsistingofasmokedetector,threeglassbreakstations,
ahorn,andstrobelight.Locatethecomponentsaccordingtotheplansupplied.
10WO10Sketch,Wiring,andProgramming(7):Drawtheschematicdiagramofacircuitconsistingofaheatdetector,threeglassbreak
stations,asirenhorn,andastrobelight.Locatethecomponentsaccordingtotheplansupplied.
11Sketch,Wiring,andProgramming(8):DrawtheschematicdiagramofacircuitconsistingofthesamecomponentsasinWorkOrder10
butwithadifferentlocation.
12Sketch,Wiring,andProgramming(9):Drawaschematicdiagramconsistingoftwopullstations,aheatdetector,asirenhorn,anda
strobelight.Useathirdpullstationasatamperswitchtosimulateasupervisorysignalintothecontrolpanel.
COURSEWAREANDACCESSORIES
ExperimentsManual
ConnectingLeadsSet