PROCESS CONTROL ACCESSORIES
At Lesman, complete service means providing you with the process control instrumentation that suits your applications,
and the accessory products that make advanced instruments work their best. From air relays and power supplies to valve
positioners and isolation barriers, weve got the instrumentation to round out your process.
Dont see what you need? Just call our ofces. Well be glad to help you. The products shown here are among the most
popular we provide our customers, but they represent only a sampling of our complete product offering. And, if we dont
have what you need, we can help you nd it.
Due to manufacturer agreements, not all products are available in all geographic areas and markets.
Prices See
Start at Page
Calibration and Testing Instruments
Ametek Handheld Pressure Testers $332.00 363
Fluke 770 Series Milliamp Process Clamp Meters $499.00 355
Meriam M200LS Lab Standard Smart Manometer $1375.00 362
Meriam MFC4150 HART Handheld Communicator $3302.00 361
Meriam MFT4010 Modular Calibrator and HART Communicator $940.00 360
Mid-West Instrument Model 830/845 Backow Prevention Test Kits $740.00 364
Taylor Pneumatic Pressure Calibrator with Indicating Gauge $290.00 363
WIKA 65-2000 Portable Electropneumatic Calibrator $4272.00 363
Power Accessories
Acopian Encapsulated Power Supply for Tough Environments $118.00 356
C R Magnetics 120 VAC Current Sensing Relay $84.56 354
GEMS Solid State Relays $127.00 356
IDEC Switching DC Power Supply $60.00 356
Phoenix Contact DIN-Rail Mount DC Power Supplies $108.17 357
Phoenix Contact Electric Line Surge Protectors $126.37 357
Phoenix Contact Intrinsically Safe Isolation Barriers $264.83 358
Phoenix Contact Power Supply Isolator with HART $456.96 357
Positioners, Filters, and Regulators
Bellofram Type 10 Precision Air Flow Regulator $117.37 352
Bellofram Type 50 Airset Regulator $51.35 352
Bellofram Type 70 High Flow Pressure Regulator $80.51 352
Siemens 760 Series Pneumatic and Electropneumatic Valve Positioners $399.00 348
Siemens SIPART PS2 Electropneumatic Valve Positioner $804.00 350
Transducers and Transmitters
C R Magnetics True RMS AC Current Transducer $191.27 354
C R Magnetics Two-Wire and Four-Wire Current Transmitters $250.70 354
Bellofram T2000 High Accuracy I/P Transducers $468.56 353
Bellofram T1000 I/P Transducer with NEMA 4 Housing $299.25 353
Bellofram T1500 Intrinsically Safe Miniature I/P Transducer $355.95 353
Phoenix Contact Signal Conditioners and Input/Output Modules $202.90 359
TABLE OF
CONTENTS
Prices in this catalog are current at the publication date, and are subject to change without
notice. Some products may not be available in all Lesman markets or geographic areas.
348
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Pneumatic and Electropneumatic Valve Positioners
VALVE
POSITIONER
Features
Universal design and choice of interchangeable NAMUR IEC 534-6
rectilinear or VDI/VDE 3845 rotary mountings provide wide applica-
tion exibility
Double-acting or single-acting service and split ranging afford ap-
plication versatility in a single unit
Non-interaction of zero and span adjustments and positive cam
locking mechanism reduce calibration and setup
Modular design supports interchangeable spare parts and reduces
inventory: 4-20 mA feedback, limit switches, NAMUR switches, I/P
module, and high ow spool valve all t inside the enclosure
Comes standard with three cams -- linear, quick opening, and equal
percentage -- for application versatility
NACE MR-01-75-compliant material ensures operation in harsh
industrial environments
Choice of beacon or fat indicator
FM, CSA, CE, and ATEX approvals
Siemens Series 760 valve positioners provide a cost-effective, universal
approach to valve control. Their modular concept allows all models to
be built on the basic pneumatic unit. The electropneumatic model is
created by adapting an I/P transducer to the base, and installing needed
accessories inside the unit.
The 760 base pneumatic unit provides cam characterization, split
ranging, direct or reverse action, and single or double acting without
requiring additional parts. Key design features include non-interaction
of the zero and span adjustments.
Series 760 valve positioners include provisions for internal limit switch
mounting and position feedback devices without the need for additional
housings, so you dont have to stack housings and impede access to the
main enclosure.
A spool valve is used to load the actuator for positioning in response
to an input signal. A characterized cam provides mechanical feedback.
The unit includes linear, equal percentage, and quick opening operation
cam proles. A blank prole cam is available for custom applications.
Rectilinear action length can range from 1/2 to 6
The feedback shaft and characterized cam can be replaced in the
eld to congure the positioner for use with either a rectilinear or rotary
actuator. Not additional parts are necessary to change between single
or double acting actuators or direct and reverse action.
Specications
Input Signal: 760P: 3-15 PSIG, 3-27 PSIG, 50% split range; 760E: 4-20 mA,
50% split range
Linearity: 760P: 0.5% span typical; 760E: 0.75% span typical
Hysteresis: 760P: 0.75% span typical; 760E: 1.0% span typical
Deadband: 0.25% span
Repeatability: Within 0.5% span
Output Conguration: Single or double acting
Action: Direct or reverse
Mechanical Feedback: 90 rotary standard; 1/2 to 6 rectilinear optional
Characterization: Equal percent, quick opening, or linear
Pressure Gain: 160:1 at 60 PSIG standard
Span: Adjustable -60% to 25% of normal span
Zero: Adjustable -10% to 60% of normal span
Supply Pressure: 150 PSIG max; Supply pressure effect: <0.2% span for a 5
PSI change in supply pressure
Air Consumption: Standard or low-gain spool: 0.5 scfm; High ow capacity
spool: 1.0 scfm typical
Flow Capacity (at 60 PSI with 25% drop): 9.0 scfm (Cv=0.3) standard; 20.0
scfm (Cv=0.6) optional
Temperature Range: 760P: -40 or -4 to 185 F (-40 or -20 to 85 C), 300 F
(148 C) optional; 760E: -40 or -4 to 167 F (-40 or -20 to 75 C)
Enclosure: Aluminum, polyester powder coated epoxy fnished, Type 4X in
accordance with NEMA standard 250, Type IP65 in accordance with IEC
standard 529
Connections: 1/4 NPT pneumatic and exhaust, 1/8 NPT gauge, 3/4 NPT
(25mm) electrical
Hazardous Area Classication Approvals: FM: Intrinsically Safe: Class I, Div
1, Groups A-D, Class II, Div 1, Groups E-G, Class III, Div 1; Non-Incendive: Class
I, Div 2, Groups A-D; Suitable for: Class II, Div 2, Groups F, G; Class III, Div 2;
CSA: Intrinsically Safe: Class I, Div 1, Groups A-D, Class II, Div 1, Groups E-G,
Class III, Div 1; Suitable for: Class I, Div 2, Groups A-D, Class II, Div 2, Groups
E-G, Class III, Div 2; CE: EN50081-1 and EN50081-2 Emission, and EN61000-
6-1 and EN60000-6-2 Immunity; ATEX: Ex II 2G EEx ia IIC T4/T5/T6, Ex II 3G
EEx nL IIC T5, SIRA 03 ATEX 2577X, SIRA 03 ATEX 4578
Using rotary or electric actuator motors for valve
positioning?
See Lesmans offering of actuators and linkage kits,
starting on page 298!
349
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
VALVE
POSITIONER
Ordering Instructions
Make one selection from each table below. A complete catalog number looks like this:
760E1 _ _ _ _ _ _ _ _.
Model Selection Guide
Notes
A Action options E, F, and S are subject to increased linearity error. Fix feedback pin in lever
to hold non-linearity error to 3% max.
B High temperature option only available on 760P models without electrical options, indica-
tors, gauges, limit switches, or feedback devices.
Catalog
Description Number Price
Siemens Series 760 Valve PAC Valve Control Positioner
Input Pneumatic, 3 to 15 PSIG 760P1 $399.00
Signal Electropneumatic, 4-20 mA DC 760E1 952.00
0.52 stroke lever, three 60 cams 4 7.00
0.54 stroke lever, three 60 cams 1 7.00
Action 0.5 4 stroke lever, one 90 linear cam E 7.00
(Rising 26 stroke lever, three 60 cams 2 7.00
Stem/ 26 stroke lever, one 90 linear cam F 7.00
Linear or 1/4 turn, 1/2 square shaft, three 90 cams 3 7.00
Rotary) 1/4 turn, NAMUR style shaft end, three 90 cams 5 0.00
[Note A] 1/4 turn, 1/2 square shaft, three 60 cams 7 7.00
1/4 turn, NAMUR shaft, three 60 cams S 0.00
No indicator, 3/4 NPT conduit connection A 0.00
No indicator, M25 conduit connection E 0.00
Enclosure 90 beacon indicator, 3/4 NPT conduit conn B 56.00
Type 90 beacon indicator, M25 conduit conn F 56.00
[Note B] 60 at indicator, 3/4 NPT conduit conn J 56.00
90 at indicator, 3/4 NPT conduit conn K 56.00
Flow Standard capacity spool valve assembly Cv=0.3 A 0.00
Capacity High ow capacity spool valve assembly Cv-0.6 B 26.00
Temp Standard temperature (-40 to 185F) A 0.00
Option High temperature (-20 to 300F) [Note B] C 99.00
Gauges None N 0.00
Set of three gauges G 62.00
Limit None N 0.00
Switches Two SPDT mechanical switches 1 148.00
Feedback None N 0.00
Devices 4-20 mA feedback 2 368.00
4-20 mA feedback, stainless steel feedback gear 4 381.00
Design Revision Level D 0.00
Approval None N 0.00
FM/CSA/CE/ATEX 6 0.00
Printed English 760 User Manual SD760 41.00
I/P module kit (converts 760P to 760E) 16300-1355 522.00
Options Pressure gauge kit (set of three) 16300-442 56.00
Standard ow spool valve kit 16300-468 123.00
High ow spool valve kit 16300-469 148.00
Spare NAMUR adapter kit TGX:16300-1556 42.00
Spare 1/2 square adapter drive TGX:16300-1545 41.00
Type 950 explosion-proof I/P transducer 16300-1048 562.00
Issue orders to: Siemens Industry Inc.,
c/o Lesman Instrument Company
Did you know...
Unnecessary air leakage can easily
reach as high as 20 to 30% of a
compressors output without notice!
Air loss can cause
Fluctuating system pressures, which can cause air
tools and other air-operated equipment motors,
diaphragm pumps, and actuators to function
less efciently, possibly affecting production
Excess compressor capacity, resulting in higher
than necessary costs
Higher cycle rates plus increased maintenance,
shorter equipment service and operating life, and
unscheduled downtime
Sources of air leaks
Couplings, hoses, tubing, and fttings
Pressure regulators
Condensate traps that leak or fail to open
Poor pipe joints or defective fange seals
Leaking shutoff valves
Average cost of air leaks
The US Department of Energys Ofce of Indus-
trial Technologies has developed a rule of thumb
to estimate the cost per year of an air leak. This cost
is calculated using an electricity rate of $0.05/kWh,
assuming a constant operation and an efcient
compressor.
Size Cost/Year
1/16 $523.00
1/8 $2095.00
1/4 $8382.00
So, every hiss you hear is potentially costing you
more than $500 per year.
Necessary air leaks
Several instruments within your system bleed air
by design, including older style pneumatic trans-
mitters, I/P and E/P transducers, booster valves, and
control valve positioners.
So, you can further decrease the cost of air leaks
by investing in valve positioners that better control
bleed, improve process quality, and reduce costs.
See pages 350351 for Siemens advanced SIPART
PS2 low air consumption smart positioners.
350
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
SIPART PS2 Electropneumatic Valve Positioners
VALVE
POSITIONER
Features
One device for both linear and rotary actuators
Choice of 0/4-20 mA with or without HART or Profbus PA
Intrinsically safe or explosion-proof housings available
Minimal own air consumption, thanks to piezo technology
short return on investment
Automatic commissioning
at initialization optimizes
control by determining zero
point, end value, direction
of action, positioning speed,
minimum pulse time, and
dead zone
Local operation and confguration with three pushbuttons
and two-line front-panel LCD display
Optional modules expand functionality for position feed-
back, alarms, and fault signaling
Basic and extended diagnostic functions accessed directly or
through Probus PA or HART protocols
IP65 rated enclosure insensitive to environmental infuences
Switch between automatic, manual, and confguration
modes at the push of a button
Fully compatible with SIMATIC PDM confguration software
Enclosures (top to bottom right):
Standard IP65 version, explosion-proof and ame-proof
model, stainless steel enclosure
SIPART PS2 excels through its reduced installation overheads, functional
expansion with low-cost option modules, and enhanced diagnostics.
You can choose between conventional 0/420 mA control technology
or the PROFIBUS PA standard. Just a single two-wire lead provides the
unit with the auxiliary power required and facilitates communication
with the control system for complete integration.
A single SIPART PS2 electropneumatic positioner works for both
linear and rotary actuators, and features your choice of PROFIBUS PA or
HART protocol for its communications capabilities.
SIMATIC PDM communications software ensures complete informa-
tion interchange with each positioner in the system. Both PROFIBUS PA
and HART provide detailed information on the history and operating
state of the valves, such as leakages, spring breakages and travel. They
can also log alarms.
With its wide range and an infnitely adjustable 3- to 130-mm stroke
range, SIPART PS2 can be directly integrated to modern actuators without
pipe work and without additional overhead.
SIPART PS2 can be used with even the smallest actuators because the
fully integrated valve block comprehends external position signals and
makes the SIPART PS2 a lot more compact.
Its user-friendly digital display shows operating states clearly, and can
be operated directly at the machine without the need for additional
equipment.
In contrast to conventional units, SIPART PS2s automatic start-up
means that you need just fve minutes for an optimum process start
with the highest control accuracy. Automatic online adaptation enables
permanent optimization of the dynamic performance.
Without adding programming overhead, Siemens has integrated
functions into the conguration menu, making SIPART PS2 a lot more
versatile. Using three pushbuttons and the two-line LCD display, you just
select the menus that deviate from the standard application.
The air loss associated with conventional positioners can be very expen-
sive. Thanks to modern piezo technology, the SIPART PS2, by comparison,
uses air only when it is required, so it pays for itself quickly.
Need diagnostics?
The SIPART PS2 provides diagnostic data about itself and its envi-
ronment, the valve and actuator. For example, a change in the valve
end-positions can be signaled automatically when a set limit has been
exceeded. Basic diagnostics include a service time counter, temperature
minimum/maximum/actual temperature, service time memory per
temperature class, and setpoint alarm detection.
Extended diagnostics include online control of the valve seat (upper
and lower end travel positions), monitoring and display of adjustable
thresholds for accumulated travel, the number of direction changes, and
the valve seat (0% position)
No matter what kind of atmosphere surrounds your SIPART PS2 posi-
tioner, the newly designed plastic enclosure and the corrosion-proof metal
housing ensure that you are equipped for all occasions. With its standard
IP65 protection, the SIPART PS2 dees even the roughest environment.
An integrated maintenance-free water separator can cope with moist
compressed air for a few days. You can forget problems caused by tem-
perature variations. Not even pressure changes in the pneumatic supply
affect control so a pressure regulator becomes a thing of the past. For
especially critical applications, external position sensors can be used.
SIPART PS2 is also available in explosion-proof housing with EExd
IIC T4/T5/T6 protection. With the help of three operating keys hidden
behind a ap, the unit can be controlled even during operation with-
out opening the housing. The display can be easily read from behind
heavy-duty glass.
351
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
VALVE
POSITIONER
Ordering Instructions
Make one selection from each table below. A complete catalog number
looks like this: 6DR5_ _ _ - _ _ _ _ _ - 0AA_
Issue orders to: Siemens Industry Inc.,
c/o Lesman Instrument Company Model Selection Guide
Catalog
Description Number Price
SIPART PS2 Electropneumatic/Digital Positioner
Input 4-20 mA, 2-Wire 6DR50 _ _- $804.00
4-20 mA, 2-/3-/4-Wire 6DR53 _ _- 825.00
4-20 mA, 2-Wire, with HART 6DR51 _ _- 907.00
4-20 mA, 2-/3-/4-Wire, with HART 6DR52 _ _- 926.00
(Note 1) Probus PA 6DR55 _ _- 1091.00
Foundation Fieldbus 6DR56 _ _- 1091.00
Actuator Single Acting _ _ _ _ _ 1 _- 0.00
Action Double Acting _ _ _ _ _ 2 _- 121.00
Plastic Housing _ _ _ _ _ _ 0- 0.00
Enclosure Aluminum Housing (Single Acting Only) _ _ _ _ _ 1 1- 121.00
Stainless Steel Housing _ _ _ _ _ _ 2- 952.00
Explosion-Proof Housing _ _ _ _ _ _ 5- 766.00
Safety None 0N _ _ _- 0.00
Rating FM/CSA Explosion-Proof 0E _ _ _- 64.00
Connection 1/2 NPT Electrical, 1/4NPT Pneumatic _ _ N _ _- 0.00
Limit None _ _ _ 0 _- 0.00
Switch Solid State Alarm Module _ _ _ 1 _- 198.00
Mechanical Limit Switch Module _ _ _ 3 _- 243.00
Option None _ _ _ _ 0- 0.00
Module 4-20 mA Position Feedback _ _ _ _ 1- 198.00
None 0AA0 0.00
Gauge Single Acting, 1/4NPT 0AA3 127.00
Block Single Acting, Stainless Steel, 1/4 NPT 0AA4 148.00
Double Acting, 1/4 NPT 0AA7 189.00
Double Acting, Stainless Steel, 1/4 NPT 0AA8 223.00
Accessories and Options
FM-Approved Alarm Module 6DR4004-7A 198.00
FM-Approved ly Module 6DR4004-7J 198.00
Mounting Set, 2-35 mm Linear Actuators (IEC 534) 6DR4004-8V 85.00
Mounting Set, Part-Turn Actuators (VDI/VDE 3845) 6DR4004-8D 65.00
Aluminum Gauge Block, Single Acting, 1/4 NPT 6DR4004-1MN 98.00
Aluminum Gauge Block, Double Acting, G1/4 6DR4004-2M 115.00
NCS Sensor for Part-Turn Actuator 6DR4004-8NN10 309.00
NCS Sensor for Linear Actuator (>14mm) 6DR4004-6NN30 566.00
RS-232 Siemens HART Modem 7MF4997-1DA 439.00
Documentation
SIPART PS2 Installation Instructions A5E00074600 24.00
SIPART PS2 Manual for Models 6DR50 to 6DR53 A5E00074631 38.00
SIPART PS2 Manual for Model 6DR55 A5E00127926 38.00
SIPART PS2 Manual for Model 6DR56 A5E00214569 44.00
Notes
1 Models 6DR53 and 6DR51 only have explosion-proof ratings when ordered
with the EExD explosion-proof housing (5)
Condensed Specications
Types of actuators: In plastic, ameproof, or stainless steel casing: Single-ac-
tion and double-action; In aluminium casing: Single-action
Travel range (linear actuators): 3130 mm (0.125.12) (angle of feedback
shaft 1690)
Angle of rotation (part-turn actuators): 30100
Power supply (inlet air): Pressure: 20.3101.5 psi, Sufciently greater than
max. drive pressure (actuating pressure)
Air quality to ISO 8573-1: Class 2 for solid particle side and density, pressure
dewpoint, and oil content
Air valve unthrottled ow: 29 psi: 18.1 gpm inlet, 36.1 gpm outlet; 58 psi: 31.3
gpm inlet, 60.3 gpm outlet; 87 psi: 43.1 gpm inlet, 84.5 gpm outlet
Valve leakage: < 0.0026 gpm
Throttle ratio: Adjustable up to :1
Power consumption in the controlled state: <0.158 gpm
Installation: On linear actuators: Using attachment set 6DR4004-8V and
where necessary with an additional lever arm 6DR4004-8L on actuators
according to IEC 534-6 (NAMUR) with ribs, bars or at face; On part-turn
actuators: Using attachment set 6DR4004-8D on actuators with mounting
plane according to VDI/VDE 3845 and DIN 3337: The required mounting
console has to be provided on the actuator side; shaft with groove and
female thread M6
Mounting position: Any; pneumatic connections and exhaust opening not
facing up in wet environment
Controller: Five-point switch: Self-adjusting; Dead zone: -dEbA = Auto, Self-
adjusting or can be set as fxed value; -dEbA = 0.110%, Self-adjusting or
can be set as xed value
A/D converter: Scan time: 10 ms; Resolution: 0.05%; Transmission error:
0.2%; Temperature effect: 0.1%/18 F
Cycle time: 20 mA/HART device: 20 ms; Probus PA device: 60 ms; Foundation
Fieldbus device: 60 ms (min. loop time)
Binary input BE1: (Terminals 9/10; electrically connected to basic device),
Suitable only for oating contact; max. load <5 mA with 3V
Vibration resistance: Harmonic oscillations (sine-wave): 0.14, 227 Hz,
3 cycles/axis; 321.84 ft/s
2
, 27-300 Hz, 3 cycles/axis; Bumping (half-sine):
492 ft/s
2
, 6 ms, 1000 shocks/axis; Noise (digitally controlled): 10200 Hz; 1
(m/s
2
)
2
/Hz (3.28 (ft/s
2
)
2
/Hz); 200500 Hz; 0.3 (m/s
2
)
2
/Hz (0.98 (ft/s
2
)
2
/Hz);
4 hours/axis; Recommended continuous duty range: 30 m/s ( 98.4 ft/s)
without resonance sharpness
Climate class 4: To DIN EN 60721-3-4; Operation: 4K3, but -22176 F (-30
80 C)
Classications: Classifcation according to pressure equipment directive
(DRGL 97/23/EC): For gases of fuid group 1, complies with requirements
of article 3, paragraph 3 (sound engineering practice SEP)
Degree of protection: IP65 to EN 60 529/NEMA 4x
CE mark: Conformity as regards EMC Directive 89/336 EC in ac-
cordance with the following standards
EMC requirements: EN 61326/A1 Appendix A.1 and NAMUR NE21 Aug. 98
Materials: Housing: Glass-ber-reinforced Macrolon plastic, GD AISi12 metal,
Austentic stainless steel # 1.4581, or Aluminium AIMgSi, anodized pressure
gauge block
Approvals: FM/CSA/ATEX; Class I, Div 1, Groups
A-D, and Zone 1 Area Ex ia/ib IIC (with suitable
intrinsically safe barrier); Class I, Div 2, Groups A-D,
and Zone 1 Area Ex ia/ib IIC; Plastic and aluminum
housing: FM intrinsically safe with customer-supplied barrier, Non-incendive,
no barrier required; Stainless steel housing: Only ATEX approved for EEx in
EEx n; Explosion-proof housing: EEx d approved
Looking for Simatic PDM software for
conguration and monitoring?
See page 188.
Need a HART handheld
communicator? See page 361.
352
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
REGULATORS
The Type 10 regulator has a 0.1%
accuracy with a low sensitivity to pres-
sure or ow changes. Startup regulated
pressure returns to its output setting
no readjustment needed.
A high-gain servo-amplier keeps
regulated pressure constant over wide
ow ranges.
An integral relief valve provides
exhaust ow when the regulated pres-
sure resets to a lower value. Assures
immediate response on dead-ends,
when downstream regulated pressure
must be reduced.
Precision Flow Regulator
Flow Capacity to 80 SCFM
Responds quickly to minute changes
in downstream pressure
Buna-N, polyester rolling diaphragms
last through millions of cycles
Integral baffe and aspir ator action
eliminates honking and buzzing
Designed for inline service and repair
Specications
Sensitivity: 1/4WC
Flow Capacity: 40, 50 or 80 SCFM @100 PSIG
supply and 20 PSIG outlet
Exhaust Capacity: 4 SCFM
Max Supply Pressure: 250 PSIG
Effect of Supply Pressure Variation on Outlet: < 0.025 PSI (25 PSIG)
Effect of Flow Changes on Regulated Pressure: (100 PSIG supply) 2.5 PSI
overow of 50 SCFM (3/8 NPT, 0-30 PSIG range, 15 PSIG setpoint)
Total Air Consumption: From 1.0 to 12.5 SCFH
Materials: Body: Diecast aluminum, vinyl paint; Adjusting Screw: Plated steel;
Trim: Plated steel, brass, acetal resin; Diaphragm: Buna-N, polyester fabric
reinforcement; Knob: Phenolic plastic; Spring: Music wire
Mounting Options: Pipe, panel, or bracket
High Flow Pressure Regulator
Air Flow Regulators
Model Selection Guide
Range Port Size Catalog
Description PSI (NPT) Number Price
High Flow Pressure 0-2 1/4 960-129-000 $85.54
Regulator 0-10 1/4 960-130-000 80.51
0-30 1/4 960-090-000 80.51
1-60 1/4 960-092-000 80.51
2-150 1/4 960-094-000 80.51
3-200 1/4 960-152-000 109.45
Also available in 3/8 port size. Call Lesman for details.
Bellofram Type 10: The Most Precise Flow
Regulator Available!
Model Selection Guide
Description Range Catalog Number Price
0-35 PSIG 960-067-000 $51.35
1/4 Airset Regulator
0-60 PSIG 960-068-000 51.35
(Gauge Not Included)
0-125 PSIG 960-069-000 51.35
Model Selection Guide
Catalog Number by Range
Port Size 2 to 25 PSI 2 to 60 PSI 2 to 120 PSI Price
Type 10 1/8 NPT 960-001-000 960-007-000 960-013-000 $117.37
Precision 1/4 NPT 960-003-000 960-009-000 960-015-000 117.37
Regulator 3/8 NPT 960-005-000 960-011-000 960-017-000 117.37
Specications
Sensitivity: 1/8WC
Flow Capacity: 14 SCFM @ 100 PSIG supply and 20 PSIG outlet
Effect of Supply Pressure Variation on Outlet Pressure: Less than 0.005 PSI @
25 PSIG; Max Supply Pressure: 150 PSIG
Exhaust Capacity: 2 SCFM; Total Air Consumption: 6 SCFH
Effect of Flow Changes on Regulated Pressure: (100 PSIG supply) 0.25 PSIG over
10 SCFM change (2-25 PSIG range, 10 PSIG setpoint)
Materials: Body: Diecast zinc alloy with vinyl paint; Capsule and Adjusting Screw:
Stainless steel; Trim: Stainless steel, brass, plated steel, acetal resin; Diaphragm:
Buna-N elastomer with polyester fabric Knob: Phenolic plastic
Compare to
Fisher 67AFR
Full line of volume boosters and relays available.
Airset Regulators
Superior regulation characteristics
Rugged, corrosion-resistant
construction
Integral 40 micron, self cleaning flter
Excellent stability and repeatability
Self-relieving
Low droop at high fow
These Bellofram regulators are gener-
ally superior in regulated pressure ver-
sus ow, forward to reverse ow offset,
supply pressure sensitivity, repeatability
and stability.
Ruggedly designed and constructed, the
regulators have housings of die-cast alumi-
num. The Type 50 regulator is nished with
vinyl paint to resist scratching, weathering,
and other physical abuse. And, its pressure-
and leak-tested prior to shipment.
A rubberized, soft-seat valve stem provides positive shut-off and for-
gives dirt or other foreign matter. An aspirator maintains downstream
pressure and compensates for droop when high ow occurs.
The full ow gauge port is convenient for gauge installation and can
also be used as an additional full ow outlet. Type 50 regulators include
a unique, self-cleaning 40 micron Nylon mesh flter that can be easily
removed.
353
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
I/P
TRANSDUCERS
I/P Transducers for Process Control
High Accuracy I/P Transducer
0.1% Accuracy Typical
Exhaust Capacity 3 SCFM at 5
PSIG Above Setpoint
Piezo-Ceramic Actuator Serves as
Control Link Between Electrical
Input and Pressure Output
The Type 2000 has been designed
to meet your electropneumatic needs:
eld-selectable inputs, direct/reverse/
split ranging, and precise, reliable perfor-
mance under extreme conditions.
Type 2000 transducers use closed-loop pressure feedback control for
precision pressure output, and to minimize the effects of temperature,
supply pressure and voltage changes, and mounting angle.
Catalog Price
Description Number Each
Type 2000 Transducer, Intrinsically Safe Enclosure 2K-SNN _- $468.56
Type 2000 Transducer, Explosion-Proof Enclosure 2K-ENN _- 551.25
FM/CSA _ _-_ _ _F- 0.00
Approvals ATEX _ _-_ _ _C- 0.00
CSA (Explosion-Proof Model Only) _ _-_ _ _G- 0.00
Electrical 4-20 mA, Direct Acting -42D_ _ _ _- 0.00
Inputs 0-10 V, Direct Acting -10D_ _ _ _- 0.00
0-5 PSIG, Full Range -_ _ _F005-00 0.00
Pneumatic 3-15 PSIG, Full Range -_ _ _F315-00 0.00
Output 0-30 PSIG, Full Range -_ _ _F030-00 0.00
3-27 PSIG, Full Range -_ _ _F327-00 0.00
0-100 PSIG, Full Range -_ _ _F100-00 0.00
Model Selection Guide
Catalog Price
Description Approval Output Number Each
I/P Transducer General Purpose 3-15 PSI 961-070-000 $299.25
4-20 mA Input General Purpose 9-15 PSI 961-073-000 299.25
General Purpose 3-27 PSI 961-074-000 299.25
General Purpose 6-30 PSI 961-075-000 299.25
180 Nominal Intrinsically Safe 3-15 PSI 961-099-000 342.33
Impedance Intrinsically Safe 3-27 PSI 961-100-000 342.33
Explosion-Proof 3-15 PSI 961-098-000 555.33
Model Selection Guide
I/P Transducer with NEMA 4 Housing
External Span and Zero Adjustments
Low Air Consumption
Built-in Volume Booster
Light Weight, Mounts at Any Angle
Specications
Linearity, Hysteresis: <1.0% span
Repeatability: <0.5% span
Supply Pressure: 3 PSIG above max output to 100
PSIG; Sensitivity: <0.1% span/PSIG at mid-range.
Min. Flow Rate at Mid-range: GP, IS Mod.: 4.5 SCFM @
25 PSIG; 12 SCFM @ 100 PSIG; Explosion-Proof Mod.:
1.9 SCFM @ 25 PSIG; 2.2 SCFM @ 100 PSIG.
Air Consumption (Max.): 0.2 m
3
/hr (0.1 SCFM) at midrange
Port Sizes: 1/4 NPT (pneumatic); 1/2 NPT (electric)
Approvals: FM approved non-incendive for Class I, Div. 2, Grps A-D, suitable for
Class II and III, Div. 2, Group G. No barriers needed. FM approved Intrinsically
Safe for Class I, II, III, Div. 1, Grps A-E and G with suitable barriers. Explosion-
Proof Model: FM approved for Class I, Div. 1, Group D; Class II, Div. 1, Groups
E-G; and Class III. FM-Rated NEMA 4 outdoor.
Features
FM, CENELEC, CSA Approved, Intrinsically Safe,
Weatherproof NEMA 4X Housing
Built-in Volume Booster for Flow Capacity to 7 SCFM
T1500 Miniature I/P Transducers
Bellofram T1500 transducers convert an electrical output signal to a
proportional output. I/P (current to pressure) and E/P (voltage to pres-
sure) models are available, as well as zero-based, extended-range units
for precise control from 0 to 120 PSIG.
These units are well suited for applications that require vibration-re-
sistant, high-fow control devices theyre rated NEMA 4X, and are built
to FM, CSA, and CENELEC specs for intrin sically safe instruments.
Model Selection Guide
Catalog Price
Description Number Each
T1500 Mini Intrinsically Safe Transducer, NEMA 4X 966- $355.95
4-20 mA DC 71 _- 0.00
Electrical 0-5 VDC 72 _- 0.00
Input 1-9 VDC 73 _- 0.00
1-10 VDC 74 _- 0.00
3 to 15 PSIG _ _ 0- 0.00
Pneumatic 3 to 27 PSIG _ _ 1- 0.00
Output 6 to 30 PSIG _ _ 2- 0.00
0 to 120 PSIG _ _ 6- 0.00
Electrical 1/2 NPTF 0 _ _ 0.00
Connection Terminal Block (Not NEMA 4X) 1 _ _ 0.00
Hirschmann Connection 2 _ _ 0.00
Elastomers Nitrile _ 0 _ 0.00
Fluorocarbon _ 1 _ 0.00
Approvals FM/CSA/ATEX Intrinsically Safe _ _ 0 0.00
Accessories DIN Rail Kit 971-140-000 9.25
3-15 PSI Pneumatic Repair Kit 971-141-000 72.80
4-20 mA Electronic Repair Kit 971-142-000 83.20
For longer transducer life, consider
installing a flter before your I/P.
To specify reverse acting, change the D to an R. To specify Split Range High, re-
place the F with an H, for Split Range Low, replace the F with an L. Other output
ranges are available. Call Lesman for details.
Call Lesman for in-stock models!
354
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Current Sensing Relay and Indicator
LED trip status indicator
No relay chatter
Electrical isolation between
circuits
The CR4395 current sensing relay
can be used to monitor electrical
heater elements, sense motor over/
under loads, detect lamp burnout, or indicate loss of phase.
Specications
Sensed Current: 200% FS max. continuous; Frequency: 60-400 Hz
Operating Class: 600V
Output Relay: One Form C
SPDT contact, three 1/4male
QC terminals
Output Life: Mechanical: 10
million operations; Electrical:
100,000 operations
Mounting: Two 3/16 dia. clearance holes on 1-15/16 x 2-15/16 centers
Model Selection Guide
Catalog
Description Number Price
Current Sensing Relay, 120 VAC Supply CR4395- $84.56
Trip Energized on High EH-120- 0.00
Status Energized on Low EL-120- 0.00
Trip 1.0 Amp to 10 Amp -110- 0.00
Ranges 3.0 Amp to 30 Amp -330- 0.00
10.0 Amp to 100 Amp -101- 0.00
Time On None -X- 0.00
Delay 0.5 Seconds to 6 Seconds -A- 0.00
2 Seconds to 25 Seconds -B- 0.00
Dial Calibrated Trip-Point Dial -CD- 0.00
Output Electromechanical Relay -ELR 8.00
CURRENT
TRANSDUCERS
Current Transmitters and Transducers
Two-Wire Current Transmitter
Loop powered, fully isolated
Permanently calibrated
Output overload protected
Specications
Accuracy: 0.5% full scale; Ripple and
noise: 1% max.
Signal Out: Calibrated: 4-20 mA DC; Maxi-
mum: 30 mA DC; Output Load: 0-600
Temperature: Range: -30 to 70C; Coefcient: .04%/C
Supply Voltage: 24 VDC 10%; Frequency: 60 Hz; Insulation Class: 600 V
Reverse Voltage Protection: Yes
Four-Wire Current Transmitter
Permanently calibrated
Fully isolated
Internal current generator
Output overload protected
Specications
Accuracy: 0.5% full scale; Ripple
and noise: 1% max., peak to peak
Signal Out: Calibrated: 4-20 mA DC;
Maximum: 30 mA DC
Temperature: Range: -30 to 60 C; Coefcient: 0.02%/C
Supply Voltage: 120VAC 10%; Frequency: 50/60 Hz; Insulation Class: 600 V
Output Load: 0-1000
Model Selection Guide
Opening Catalog
Description Size Number Price
0 - 5 Amps 0.93 dia. CR4320-5 $349.64
0 - 10 Amps 0.93 dia. CR4320-10 349.64
Two-Wire 4-20 mA 0 - 15 Amps 0.93 dia. CR4320-15 349.64
Current Transmitter 0 - 20 Amps 0.93 dia. CR4320-20 349.64
0 - 30 Amps 0.93 dia. CR4320-30 352.74
0 - 50 Amps 0.93 dia. CR4320-50 468.76
Full Scale Range 0 - 75 Amps 0.93 dia. CR4320-75 468.76
Range (AC) 0 - 100 Amps 0.93 dia. CR4320-100 372.86
0 - 150 Amps 0.93 dia. CR4320-150 389.87
0 - 200 Amps 0.93 dia. CR4320-200 389.87
0 - 300 Amps 1.25 dia. CR4320-300 411.53
0 - 400 Amps 1.25 dia. CR4320-400 425.44
Model Selection Guide
* Range set with eld-selectable switch.
Opening Catalog
Description Size Number Price
Four-Wire 0 - 5 Amps 0.94 dia. CR4340-5 $430.08
4-20 mA 0 - 10, 0 - 15, 0 - 20 Amps* 0.94 dia. CR4340-20 468.76
Current 0 - 25, 0 - 50, 0 - 75 Amps* 0.94 dia. CR4340-75 250.70
Transmitter 0 - 100 Amps 2.13 dia. CR4340-100 502.80
0 - 150 Amps 2.13 dia. CR4340-150 262.20
0 - 200 Amps 2.13 dia. CR4340-200 502.80
Full Scale 0 - 300 Amps 2.13 dia. CR4340-300 502.80
Range (AC) 0 - 400 Amps 2.13 dia. CR4340-400 526.01
0 - 600 Amps 2.13 dia. CR4340-600 526.01
True RMS AC Current Transducer
24 VDC powered
Connection diagram printed on case
Use with external current transformers
35mm DIN rail or panel mount
Specications
Accuracy: 0.5%
Frequency Range: 20 Hz to 5 KHz
Mean Time Between Failures: >100 K hours
Output Load: 4-20 mA: 0 to 300; 0-5 VDC: 2K or greater
Model Selection Guide
Catalog
Description Number Price
Single Element Transducer, 0-5 VDC Output CR4110-* $191.27
Single Element Transducer, 4-20 mA DC Output CR4120-* 211.60
*Add sufx 0-10 Amp AC .....................10 0-30 Amp AC ..................... 30
for input range 0-15 Amp AC .....................15 0-40 Amp AC ..................... 40
0-20 Amp AC .....................20 0100 Amp AC ...............100
Voltage, N/O N/C
Load Type Contact Contact
240 VAC, Resistive 20 A 10 A
240 VAC, Motor 2 HP 1/2 HP
125 VAC, Motor 1 HP 1/4 HP
28 VDC, Resistive 20 A 10 A
Contact Rating: UL508/873, CSA
Call for 230 VAC and 24 VDC models and other trip ranges.
355
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Are you spending time
Taking mA measurements by removing a wire and breaking the loop?
Calling the control room to isolate a loop?
Testing analog input/output on a console?
Troubleshooting devices with mA inputs and outputs?
Repairing intermittent or erratic 4-20 mA loops?
Going back to the shop to get extra tools?
Fluke meters are designed to save you time and money by eliminating time-
wasting activities. Now, you can troubleshoot and repair 4-20 mA loops without
breaking the loop or bringing down the system.
The Fluke 771 Milliamp Process Clamp Meter is a hand-held battery-operated
clamp meter that measures 4-20 mA dc without breaking the electrical circuit.
Unlike conventional clamp meters, the Fluke 771, 772, and 773 feature a remote
jaw that connects to the main body by extension cable.
Milliamp Process Clamp Meters
Common Features
Measures 4-20 mA signals without breaking the loop
Measures 10-50 mA signals in older control systems using
the 99.9 mA range
0.2% accuracy, 0.01 mA resolution and sensitivity
Measure mA signals for PLC and control system analog I/O
Dual backlit display shows both mA measurement and per-
cent of 4-20 mA span (0 to 100%)
Measurement Spotlight feature illuminates hard-to-see wires
in dark enclosures
Detachable clamp with extension cable for measurements in
tight locations
Automatically change the 4-20 mA output for remote testing
Auto power-off and backlight timeout extend battery life
Hold function captures and displays changing measure-
ments
Electronic zero
Models 772 and 773 Add
In-circuit measurement of 0-24 mA DC and up to 99.9 mA DC
using a remotely connected clamp via extension cable
Ability to source, simulate, and measure 024 mA signals in
circuit to conrm non-contact measurement
24 VDC loop power supply to power a transmitter and test its
mA output signal for troubleshooting
250 HART resistor for mA source
Model 773 Adds
Source and measure 1-5 or 0-10 VDC process signals to
troubleshoot input and output devices like chart recorders
Dual channel mA source and measurement (4-20 mA in/out)
for troubleshooting
Scaled 4-20 mA output
Specications
All Models
Accuracy: 0.2% +2 counts unless stated otherwise
mA Measurement by Clamp: 0-20.99 mA range; 21.0 mA to 100.0 mA with
1% +5 count accuracy
772 and 773 Models
mA Measurement in Series with Test Jacks: 0-24.00 mA range
mA Source: Maximum mA drive 24 mA into 1000; 0 to 24.00 mA range
mA Simulate: Maximum voltage 50 VDC; 0 to 24.00 mA range
773 Models
Voltage Source: 2 mA maximum drive current; 0 to 10.00 VDC range
Voltage Measure: 0 to 30.00 VDC range
Operating Conditions: Temperature: 14 to 122 F (-10 to 50 C); Humidity:
<90% @ <86 F, < 75% @ 86 to 131 F (30 to 55 C); Altitude: 02000 m
Measurable Conductor: 0.177 or 4.5 mm max diameter
Vibration: Random 2 g, 5 to 500 Hz
Shock: 1 meter drop test (except the jaw)
EMI/RFI: Meets EN61326-1. For current measurement with jaw, add 1mA to
specication for EMC eld strengths of 1V/m up to 3V/m.
Power and Battery Life: 771: Two AA 1.5 V Alkaline, IEC LR6, 40 hours typical;
772 and 773: Four AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into
500
Model Selection Guide
Catalog
Description Number Price
Fluke 771 Basic mA Process Clamp Meter 771 $499.00
Fluke 772 Advanced mA Process Clamp Meter 772 695.00
Fluke 773 Advanced mA/Voltage Process Clamp Meter 773 995.00
What Comes With It?
Fluke 771 meter comes with two AA Alkaline batteries, a soft carrying case
and users manual.
Fluke 772 and 773 meters come with four AA Alkaline batteries, TL75 test leads,
AC72 detachable clip, TL940 mini hook test leads, hanging tool with hook and
loop strap, soft carrying case, and instruction sheet.
DIGITAL
CALIBRATORS
356
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Power Supplies, Relays and Accessories
Encapsulated for Harsh Environment
UL Recognized
Easy-to-Wire Terminal Strip
No Heat Sink or De-rating Required
Short-Circuit-Protected
Model Selection Guide
Catalog
Output Number Price
Encapsulated 24 Volts DC 100 mA 24EB10 $118.00
Power Supply 24 Volts DC 200 mA 24EB20 148.00
24 Volts DC 600 mA 24EB60 211.00
Accessories Required mounting plate EB4A 12.00
Specications
Voltage: Input: 105-125 VAC, 47 to 420 Hz, single
phase; Output: 24 VDC
Output Trim Adjustment: Outputs factory preset to 2% (1-9V models) or
1% (10-75V models) of nominal voltage. Single output models can be
trimmed to nominal voltage rating with an external trim resistor.
Dont forget to order a mounting plate!
POWER
ACCESSORIES
Low-Current Relays
These relays can be used with any dif-
ferential control switch for Start/Stop or
On/Off switching. To reduce nuisance shut-
downs, units hold the operational state up
to a half second during momentary power
loss. Low voltage protection is inherent.
Model Selection Guide
Operating/ Max. Sensor SPST Switch Catalog Price
Model Load Voltage Current Operation Number Each
Flip-Pak 100130 VAC 20 mA N/O 28196 $127.00
Intrinsically Safe Relays for
Power in Hazardous Areas
Eliminates the need for hard-to-
mount explosion-proof enclosures.
Provides non-mechanical opera-
tion by arc-free response.
Fully encapsulated, tamper-proof
and shock- and vibration-resistant.
Impervious to dust and moisture.
Housing: Polysulfone
Operating Range: Voltage: 120 VAC, 5 Amp; Temperature: -40 to 120 F
Switch Operation: SPST, Normally Open; Sensor closure up to 1000 resis-
tance control, resistive loads to 5 Amp at 120 VAC.
Model Selection Guide
Series Catalog No. Price
GEMS Safe-Pak, Low Sensitivity, SPST, N/O 144600 $188.00
No jumpers or dip switches
DIN rail or panel mount
LED operation indicator
Universal AC input (85264 VAC)
DC compatible input (105370 VDC)
UL508 listing; CE marking according
to both LVD and EMC
Unique spring-up, fnger-safe terminals (ideal for
ring lug terminated wire
Auto resetting output over current protection
Switching DC Power Supply
Specications
Output Capacity: 23 VDC at 300 mA; Leakage Current: 0.75mA max.
Input Voltage (single-phase, 2 wire): 100240 VAC (85264 VAC), 50/60Hz
(4763Hz); Overvoltage Protection: Output turns off at 105% (typical)
Internal Fuse Rating: 2A
Overload Protection: 120% typical (Zener-limiting)
Operating Conditions: 14 to 140F (-10 to 60C); 20 to 90% rH
Model Selection Guide
Catalog
Description Number Price
24 VDC Power Supply, 7.5W, 300mA Output PS5R-A24 $60.00
24 VDC Power Supply, 15W, 600mA Output PS5R-B24 86.55
12 Length DIN Rail BNDN-12 3.95
DIN Rail Clip BNL5 2.00
Need a powered enclosure box? Talk to
your Lesman sales associate about building a
Hoffman enclosure pre-wired and pre-powered
to your exact specifcations. We can help!
Features
Class 1, Div 2-Ready feld-mount
Hoffman enclosure
Two holes in bottom of enclosure
for easy wiring
DIN rail inside enclosure for
mounting modules
Include your choice of DIN rail
mountable power supply
Specications
14 gauge steel, with seams con-
tinuously welded and ground
smooth
ANSI 61 gray polyester powder
paint inside and out, over phos-
phatized surfaces
Heavy gauge continuous hinge with stainless steel hinge pin
Suitable for indoor or outdoor use, wherever protection from dust,
dirt, oil, or hose-directed water is essential
357
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
POWER
SUPPLIES
Mini Power DIN Rail Mount DC Power Supply
Model Selection Guide
Catalog
Description Number Price
DIN-Rail 24 VDC Power Supply, 1A 2938840 $108.17
DIN-Rail 24 VDC Power Supply, 1.3A 2866446 108.17
DIN-Rail 24 VDC Power Supply, 2A 2938730 141.37
Specications
Input voltage: 85 264 VAC, 90 VDC350 VDC
Output voltage: 24 V (Signal); Range: 22.528.5 VDC (>24 V
constant capacity)
Nominal voltage: Input: 100 240 VAC; Output: 24 V 1 %
Current: Output: 1.3A; 1.6A @ 40C (With POWER BOOST) ; Inrush
surge: <15 A typical; Continuous: Max. 20 mA
Input fuse: 1.25 A (Slow-blow, internal)
Maximum power dissipation idling: 1 W
Power loss nominal load max.: 4.5 W
Status display: LED green
Ambient temperature: -2570C (> 60C derating)
Slim power supply for use in performance class up to
100 W. The consistent provision of a input of 85264 VAC or
90350 VDC, an integrated power reserve, POWER BOOST,
ensures safe operation in AC and DC networks.
MiniPower provides the total output capacity for more
than 20 ms in the case of a power failure. Mini Power has
approvals such as UL 60 950 for IT equipment, UL 508 for
industrial control equipment, and RoHS compliance.
Enclosure: IP20, Class 2 (in an enclosed control cabinet) Instal-
lation: Horizontal DIN rail
Approval: UL; EN 60950/VDE 0805 (SELV); DIN VDE 0100-410, DIN
VDE 0106-1010; CE compliance with EMC directive 89/336/EEC;
Emitted interference: EN 50081-2; Immunity: EN 61000-6-2
Single Phase Primary Switched Power Supply
Phoenix Contact QUINT power devices are designed
for universal use. QUINT units offer guaranteed supply
powerful capacitors ensure mains buffering of more than
20 ms at full load. Preventive function monitoring diagnoses
problem operating states and minimizes downtime in your
system. An active transistor output and a oating relay
contact are used for remote monitoring.
All QUINT devices are idling- and short-circuit-proof,
and are available with a regulated and adjustable output
voltage of 12, 24, and 48 VDC.
Model Selection Guide
Catalog
Description Number Price
DIN-Rail 24 VDC Power Supply, 5A 2938581 $314.40
Specications
Voltage: Input: 85-264 VAC, 90-350 VDC input range; 100-240
VAC nominal; Output: 24 VDC 1% nominal
Input fuse: 5 A (Slow-blow, internal); Circuit breaker 6A, 10A,
or 16A characteristic B recommended backup fuse
Current: Inrush surge: <20 A (Typical); Consumption: 1.6A at 120
VAC nominal; Output: 5 A; 7.5 A (With POWER BOOST)
Mains buffering: >20 ms at 120 VAC
Power dissipation: 14W max nominal load, 2W max no load
Ambient temperature: -2570C (> 60C derating)
Enclosure: IP20, NS 35 DIN rail mount per EN 60715
Approval: UL/cUL recognized 60950, UL/cUL listed UL 508
Model Selection Guide
Description Catalog Number Price
Power Supply Isolator with HART, 4-20 mA 2810900 $456.96
Power Supply Isolator with HART
This DIN-rail mount power supply isolator
simultaneously supplies two- or three-wire eld
transmitter analog signals plus bidirectional
HART data. The digital data signals take prece-
dence over the analog current signal as needed
for transmitter diagnostics and calibration.
Specications
Supply Voltage: 20-30 VDC
Transmitter supply: Voltage: 20-32V; Current:
<30 mA
Housing: Unarmored Polyamide with plug-in screw
clamp terminals
Approval: CE, conforms to EMC Directive 89/336/EEC and Low Voltage
Directive 73/23/EEC
Electrical Line Surge Protectors
Model Selection Guide
Catalog
Description Number Price
115 VAC Surge Protector: Surge Plug and DIN Rail Base 2856812 $126.37
Replacement AC Surge Plug, 115 VAC, 20 A 2839334 95.72
Surge Plug Unit for 24 VDC Current Surge Protection 2838228 245.08
DIN Rail Base for 24 VDC Current Surge Protection 2839224 75.06
Increased uptime starts with a quality pow-
er supply. Reducing vulnerability to surges
can further increase uptime and extend the
life expectancy of your device.
These RoHS-compliant surge protectors
are modular, so if theres damage, only the
damaged surge plug needs to be replaced
no shutting down the power supply.
Pair these surge protectors with your Phoe-
nix Contact power supplies to extend their
warranty to ve years unconditional!.
358
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
ISOLATION
BARRIERS
Intrinsically Safe Isolation Barriers
Features
High density, dual channel designs
save cabinet space
DIN-rail mounting and plug-in
terminations for easy replacement and maintenance
Transformer isolation and fltering integrated to eliminate
noise, ground loop problems, and to provide intrinsic safety
without a high integrity ground connection
LED indicators for power, signal status, and line fault detection
Three-way electrical isolation (input, output, and supply)
Certifcation according to 94/9/EU (ATEX), FM, cUL standards
Class 1, Div 1, Groups A-G, and Class 1, Div 2 location approvals
Test sockets for easy testing on analog barriers
Call for barriers for analog outputs or temperature inputs.
Barriers for Analog Inputs
Single channel
Two- or three-wire 4-20 mA input, with or without HART
24 VDC power required
These repeater power supplies feed intrinsically safe 4-20 mA to
two-wire or three-wire measuring transducers in the hazardous area,
and transmit the signal to a load in the safe area. The HART protocol
I/O repeater model is capable of two-way transmittal of data protocols
for smart transmitters.
The voltage transducer serves as interface between the electrical
signals from the Ex area and the non-Ex area. It converts voltages in the
range of -10 to 10 VDC to a 4-20 mA signal.
Model Selection Guide
Why use an intrinsically safe isolation barrier?
Intrinsic safety standards require for instruments in hazardous locations that certain
points of the system be grounded, and others be isolated from ground.
Grounding intrinsically safe circuits reduces the probability of generating excessive energy
levels. Isolation from ground prevents the possibility of having two grounded points with
different potentials, and the possible circulation of a high current.
IS standards also require that only one point be grounded, and the rest of the circuit isolated
from ground (500 VAC min.). This is done with a conductor connected to the reference ground
system and isolated from any other plant grounds.
Isolated barriers
The grounding requirement, maintenance, and testing can be considerably reduced by
using isolated barriers that dont require a maintained IS ground. The circuits are foating
ground systems, and are usually equipped with three transformers (on input, output, and
power). Below, you can see a comparison of wiring methods using isolated barriers.
Conventional passive IS Zener barriers
1 A good ground connection must be provided
and maintained
2 Field devices must be isolated from ground
3 Voltage drop across the barriers can make
some applications difcult
4 Improper connection or voltage surges could
blow the fuse
5 Poor common mode rejection values
Active (powered) IS isolation barriers
1 Ground connection not required
2 Field devices can be grounded
3 Full voltage is available to eld devices
4 Reverse polarity protected and surge arrestors
incorporated
5 Tolerates high common mode voltage
6 Combines signal conditioning and circuit
protection
7 Simple installation without ground loops
Catalog
Description Input Output Number Price
I/O Repeater 0/4-20 mA 0/4-20 mA 2835435 $352.22
I/O Repeater with Hart 0/4-20 mA 0/4-20 mA 2835422 476.70
Barriers for Digital Inputs
Dry contact or NAMUR discrete inputs
Relay dry contact Form C output
24 VDC power required
NAMUR switching ampliers operate proximity sensors and switches in
hazardous areas. All models feature one-line error detection per channel,
which can be switched on and off, depending on the application.
All units accept inputs from NAMUR proximity sensors, oating
switching contacts, and switching contacts with resistance circuits. For
all Ex-NAMUR switching ampliers, two switches on the front panel of
the housing let you choose between normal and reverse switching
behavior for each channel.
Model Selection Guide
Catalog
Description Output Power Number Price
Two Channel SPDT Relay 24 VDC 2835493 $311.17
Switching Amplier SPDT Relay 120 VAC 2835781 264.83
Barriers for Digital Outputs
Single and dual channel solenoid drivers
Loop powered
24 VDC x 65 mA input and output
The solenoid drivers link a switch or voltage source installed in a safe
area to a device isolated in the hazardous area. Intrinsically safe solenoid
valves, alarm modules, or other intrinsically safe devices can be connected,
and simple electrical devices (LEDs) can be operated.
Model Selection Guide
Catalog
Description Number Price
Valve Control Block, Dual Channel, IS Output 2835752 $463.45
359
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
SIGNAL
CONDITIONERS
Signal Conditioners
Transmission Cutoff
Error of Frequency Supply Design Catalog
Input Output End Value -3 dB Voltage Width Number Price
Isolating Ampliers
0-10/0-5 V, mV/V/mA Ranges 0-10/0-5 V, mV/V/mA Ranges <0.1% 450 Hz 18-30 VDC 17.5mm 2810887 $394.65
0/4-20 mA, 0-10V 0/4-20 mA, 0-10V <0.1% 10 Hz/10 kHz 20-253 VAC/DC 12.5mm 2814838 477.72
0/4-20 mA 0/4-20 mA <0.2% 30 Hz 20-30 VDC 12.5mm 2814508 235.39
Signal Multipliers
0/4-20 mA, 0-5/10V 0/4-20 mA, 0-5/10V <0.2% 30 Hz 20-30 VDC 17.5mm 2814867 415.41
Loop-Powered Isolators
0/4-20 mA, 0-10V, 0-5V,
20 mA, 10V, 5V 4-20 mA <0.1% 30 Hz Loop Power 17.5mm 2814058 318.49
0/4-20 mA 1-Chan 0/4-20 mA 0.10% <75 Hz Loop Power 12.5mm 2814016 276.94
0/4-20 mA 2-Chan 0/4-20 mA 0.10% <75 Hz Loop Power 12.5mm 2814029 505.42
0/4-20 mA 4-Chan 0/4-20 mA 0.10% <75 Hz Loop Power 22.5mm 2814045 671.58
Repeater Power Supplies
4-20 mA 4-20 mA, Hart <0.1% 30 Hz 20-30 VDC 17.5mm 2810900 456.96
4-20 mA 4-20 mA <0.1% 30 Hz 20-30 VDC 17.5mm 2814553 387.72
Strain Gauge/Load Cell Ampliers
0.1-200 mV/V 4-20 mA, 0-5/0-10V 30/1000 Hz 24 VDC 22.5mm 5604058 429.46
0.1-1000 mV/V 4-20 mA, 0-10V, 10V 30/5000 Hz 24 VDC 22.5mm 5603007 676.72
Frequency Transmission
Measuring Error of Supply Design Catalog
Input Output Range End Value Voltage Width Number Price
Active Current Transducers
0-0.2 to 0-55 Amp 0/4-20 mA, 0/2-10 V, 10V, 5V 15-400 Hz <0.5% 20-30 VDC 22.5mm 2814715 357.89
0-9.5 to 0-55 Amp 0/4-20 mA, 0/2-10 V, 10V, 5V 15-400 Hz <0.5% 20-30 VDC 22.5mm 2814728 357.89
Transmission
Error of Supply Design Catalog
Input Output End Value Voltage Width Number Price
Voltage Transducers 0-20 VDC to 0-660 VDC 20 mA, 10 V <1% 18.5-30.2 VDC 22.5mm 2811116 439.69
Frequency 0/4-20 mA, 0-10 V,
Transducers 0 Hz to 120 kHz 0-5V, Inverse Values <0.15% 30 VDC 45mm 2814605 402.41
Serial Interface Converter RS-232 x 1 or 2 Channels Isolated RS-485 24 VDC 22.5mm 2744416 305.90
Temperature Relays Pt100 RTD SPDT Relay 250 VAC/2 Amp AC 20-30 VDC 12.5mm 2814948 202.90
The transmission of analog signals in industrial environments is very
susceptible to interference. Phoenix Contact modular converters for
measuring and control technology avoid the distortion of analog signals
caused by external interference.
With accurate conversion, electrical isolation, and adaptation of ana-
log signals, they provide increased transmission quality, to improve the
quality of your control circuit.
Confgurable amplifers with electrical isolation between input, output,
and supply power.
Signal multipliers to double analog standard signals.
Repeater power supplies for the supply and transmission of signals
from two- or three-conductor transducers.
Confgurable loop-powered isolators for electrical isolation without
auxiliary power supplies.
Active True RMS current transducers for converting sinusoidal alter-
nating currents in the ranges 0-1 and 0-5 Amp
Confgurable and programmable True RMS current transducers for
converting DC, AC, and distorted currents into the ranges 0-0.2 to
0-55 Amps.
Programmable transducers for frequencies up to 120 kHz
Transducers for converting DC voltages up to 660V and AC voltages
up to 440V
Transducers for measuring potentiometer settings up to 20 k
Temperature relays
Model Selection Guide
Dont see the signal conditioner you need? Call 800-953-7626. Well help you nd it.
360
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
HART
CALIBRATOR
MFT4010 Modular Calibrator and HART Communicator
The MFT 4010 is a break-through combination calibrator and HART
communicator that truly reduces the time spent on eld calibrations.
The MFT 4010 Series delivers the versatility of a calibrator and the con-
venience of HART communications in one handheld unit. Users can view
up to four measurements simultaneously on the high resolution LCD or
compare HART PV and AO values to corresponding values measured by
the NIST traceable MFT.
Documentation of calibration results and HART congurations is
standard. Available modules include differential, gauge, vacuum and
absolute pressure as well as temperature, and voltage/current. A voltage
and current meter is integral to the base unit.
All HART eld devices can be congured, polled, and trimmed using
HART communications. Device Specic commands for supported devices
are included with the MFT.
Meriam modules can be installed into any of three sensor bays. The
modules are completely interchangeable and can also be hot-swapped
to facilitate most any testing needs.
Pressure and differential pressure sensor
modules are available in several ranges to pro-
vide the ultimate in exibility and convenience
for calibration standards.
The RIO4000 RTD module accurately mea-
sures or simulates the resistance of 22 different
RTD sensor types with nominal resistance to
4000. Two-, three-, and four-wire RTDs are
supported for platinum, copper, nickel, or iron.
The module can simulate temperature to all
conventional or smart temperature transmit-
ters and signal conditioners.
The TIO0110 thermocouple module can ac-
curately measure or source 110 mV for any of
twelve different thermocouple types accord-
ing to NIST 175, ITS-90, or ITS-68 standards.
Supports thermocouple types B, C, E, J, K, N, R,
S, T, M, and P.
The VMA0055 is a DC voltage and current measurement and simula-
tion module. Measurement ranges include 500 mV, 55 V, and 100 mA.
Sourcing capabilities include 1000 mV, 0 24 V and 0 22 mA. The VMA
module will also simulate transmitter outputs when connected to a loop. It
can also be used to temporarily supply 24V DC loop power to unpowered
devices during commissioning, outages or calibration activities.
Features
Takes the place of multiple handheld instruments, simplifes workload and improves productivity.
Automation for HART feld devices Calibration is automated through calibrator auto setup based
on the device settings; digital trims automate the device adjustment steps.
Supports calibration for pressure, thermocouple, RTD, I/P, P/I, switch, loop and mA/V for conventional
devices, HART transmitters, or local indicators.
Document As-Found and As-Left results
Field updates via Internet downloads to update calibrator or add capabilities and HART support
Field recertifcation Sensor modules and integral V/I can be recalibrated for zero, span, and linearity
2.1 x 2.1 display confgurable for 1 to 4 simultaneous measurements with four soft keys and eight
hard keys.
Auto shut off, damping, Min/Max value, display Hold, sensor Zero, direct Contrast adjustment.
Diagnostic self-tests run at power up and installation of sensor modules.
Dedicated memory holds up to 500 HART device drivers.
Specications
Base Unit: ABS plastic case with three bays for measurement modules
Keypad: Overlay keypad with 10 dome contact style buttons and 4 soft keys.
Alpha entry based on LCD alpha matrix; numeric entry with buttons.
Display: 128 x 128 pixel graphic display, 5-digit resolution
Power: Six AA alkaline or NiMH batteries, AC power adapter
Connections: 3/4 center banana jacks for 50 mA DC and for HART; Data
Transfer: DB-9 for RS-232C
Certications: CE Approval; Intrinsically Safe, Class I, Div I areas per CSA 22.2
& UL 913 by MET Laboratories
Operating Temperature: 23 F to 122 F (-5 C to 50 C)
NIST Traceable Accuracy: 0.025% full scale 0.001% span per F
Modules: Positive-lock with spring latch. Electrical connections are PC board
contacts to spring loaded receivers on base unit.
Device Management System (DMS) Software: Full calibration and con-
guration management database featuring secure device history, report
generation, search functions and calibration scheduling.
Catalog Price
Description Number Each
MFT Multifunction Calibrator MFT4000-1 $940.00
MFT Multifunction Calibrator with HART MFT4010-17 3573.00
Differential Pressure Sensor Module, 0-400 H2O DDN0400 830.00
Gauge Pressure Sensor Module, 0-200 PSI DGI0200 919.00
Linear Simulator Module (mV, V, mA) VMA0055 767.00
VMA0055 Starter Kit A900529-00015 71.00
Thermocouple Simulator Module (12 TC Types) TIO0110 754.00
Connector Kit for TIO0110 A37062 170.00
RTD Simulator Module (22 RTD Types) RIO4000 987.00
Connector Kit for RIO4000 A37063 125.00
Model Selection Guide
Calibrator units come complete with two blank inserts for open sensor bays,
AC power adapter, test lead kit, RS-232 serial communications cable, protective
rubber boot, Meriam DPC manager utility for updating rmware and HART
device drivers.
MFT4010 also includes a HART lead kit with 250 shunt adapter and a three-
year DOF subscription to www.Meriam.com for access to new device les.
Starter/connector kits contain test leads, plugs, connectors, cables, and alligator
clips needed to use the sensor and simulator modules with your MFT calibrator.
Dont see the pressure or differential pressure sensor
range you need? Call Lesman for other available models.
361
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
HART
HANDHELD
The MFC 4150 HART Communicator is the new latest HART commu-
nicator from Meriam Process Technologies with features that optimize
commissioning, conguration, and maintenance operations.
HART eld devices can be congured, polled, and trimmed using the
4150/4150X with HART communications.
The MFC4150/4150X display is a 128 x 128 pixel graphic display with
backlight. Viewable area is 2.6 x 2.6 for 13 viewable message lines. The
display provides three types of information: (1) header information
including display titles, HART communication status indicator, SHIFT
indicator, alpha or numeric entry mode indicator and battery gauge, (2)
main data display section for display of operating menus, HART menus,
and device information, and (3) footer information dening the displays
soft key functionality.
MFC 4150 supports all HART devices at the Universal and Common
Practice command levels plus a large and growing list of devices at
the Device Specic command level. View the eld device list by going
to www.Meriam.com and selecting Resources > Download Center >
Available DOFs.
Firmware upgrades and new DOFs can be downloaded via the In-
ternet in two ways. The rst way is to use the DPC Manager utility on a
PC with Internet access to download les from the DOF Download Site
automatically and then update the 4150/4150X.
The second way is to use the DOF Download Site to download the
needed les to the host PC and then use the DPC Manager utility to
coordinate the update of the 4150/4150X. The Download Site lets you
stay current as new DOFs or revisions of existing ones are posted.
Automatic email notices of new DOF postings are sent to all users who
have logged on to the Download Site and registered their email address
under Subscriber Options. Firmware updates are free of charge. DOFs
are available by subscription (included in -01 models).
Specications
Base Unit: ABS plastic case, keypad, 2.1 square viewable area display
Operating Temperature: 23 to 122F (-5 to 50C)
Keypad: Membrane, four soft + eight single function, 30 dual function, and
three thumb keys
Display: 13 line, 128 x 128 pixel graphic display with backlight
Power: Six AA alkaline or NIMH batteries; 100-240 VAC power adapter. Use
only approved Alkaline batteries for MFC 4150X units
Connections: Standard banana jacks(3/4center) for HART, Odu connector
for dongle, AC adapter power and DB-9 serial communications.
Certications: CE, EMC testing as battery powered, portable ATEX Intrinsi-
cally safe (approved AA alkaline batteries only). Ex II 1 G; EX ia IIC T4, Class
I, Div. 1 Groups AD: T4; 4150X Certifcations: Intrinsically safe, Exia, Class I,
Zone , AEX ia IIC T4, Ex ia IIC T4, -5C<Ta<+50C
Features
Just 15 seconds from power-up to use!
Smaller and faster than the competitors model, with eight times the storage
capacity (See comparison below)
CE-approved general purpose and ATEX/UL-approved intrinsically safe models
Alkaline or NiMH battery power; Average 28-hour battery life, up to 60 hours without backlight
Document and store 200 confgurations; Clone, upload, and download confgurations; Offine
mode for editing and reviewing congurations
Alphanumeric keypad with menu shortcuts for frequently used commands, dedicated text edit
keys, HART menu Home key and left-side thumb keys for easy one-handed navigation
Update frmware and device fles for up to 420 HART devices from Meriams website
How does the MFC stack up against the competition?
Feature Meriam MFC4150 Rosemount 375
Startup time
(ON to Ready)
15 seconds typical 80 seconds typical
Battery type Six AA Alkaline batteries or NiMH
(Buy spares anywhere, 8-pack, average $7.99)
Proprietary rechargeable battery pack
(Spare purchase price $325.00, recommended
if using unit for more than 8 hours at a time)
Battery life 60 hours life, 28 hours with backlight 2 to 4 hours
Memory Document and store 200 congurations Document and store 25 congurations
Dimensions 10.375 x 4/125 x 1.875 (HWD), 1.7 lbs. (HWD) 10 x 5.75 x 2.25, 2 lbs 4 oz.
Ergonomics Comfortably handheld Larger handheld
Review feature Includes edit capability Review only, no edit capability
Keypad Full alpha keypad Coded alpha entry with touchscreen or stylus
MFC 4150 HART Handheld Communicator
All communicator kits include: CE or ATEX approved HART communicator, HART lead
kit, one 6-pack AA Alkaline batteries, communication/AC adapter dongle, RS-232
serial cable, universal power adapter, protective boot, soft carrying case, adjustable
shoulder strap, user manual, software CD with Meriam DPC manager utility for
downloading and installing rmware and device le updates. (Only -01 models
include the subscription to the DOF download site at www.Meriam.com.)
Model Selection Guide
Description Catalog Number Price
Communicator with 3-Year Device File Download Website Subscription
General Service HART Communicator MFC4150-01 $3847.00
Intrinsically Safe HART Communicator MFC4150X-01 4046.00
Communicator, No Download Subscription
General Service HART Communicator MFC4150-00 3302.00
Intrinsically Safe HART Communicator MFC4150X-00 3501.00
View the feld
device list at
www.Meriam.com
Select
Resources >
Download Center >
Available DOFs.
362
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Todays maintenance technicians need accurate and exible test gear to
tackle as many applications as possible. Because pressure measurements
made by OEM equipment can be displayed in many different engineering
units, technicians need the fexibility to quickly change units and to be
condent of resulting accuracy and resolution.
Meriams M200LS lab standard smart manometer offers the best avail-
able pressure measurement accuracy in a portable, handheld format. The
NIST traceable accuracy is typically 0.01% full scale, and is independent
of temperature effect over an operating range of 59 to 86 F.
M2 pressure sensors are available to measure gauge, differential,
absolute or vacuum pressure. The display can read out in any of eleven
pressure units or can be linearly scaled for special user units. Differential
models offer a square root fow function to display fow rate in user
dened units.
An adjustable damping feature minimizes the effects of pulsating
pressures. A Min/Max function captures the extremes of pulsating or
varying pressure signals and a Hold function can freeze the display at
any point of interest. Auto Record documents up to 240 readings for
future recall.
Specications
Accuracy: 0.01% full scale except DN0028 (0.02% full scale accuracy)
Base Unit: Polycarbonate, permanently dissipative, ESD protection; Five-
button sealed membrane-type keypad; Five signicant digit LCD, two line
x 16 character display with contrast adjustment, two-stage backlight, and
visual overrange indication
Power: Four AA batteries providing 100+ hours of continuous use
Wetted Parts: DN: 316L SS, brass, Viton; GI: 316L SS; AI: 316L SS
Connections: 1/8 female NPT, 316L SS
Operating Temperature: 59 to 86 F (15 to 30 C)
Model Selection Guide
M200LS Lab Standard Smart Manometer
Features
Accuracy 0.01% full scale for most units
Isolated gauge or absolute pressure sensors for fuids compatible
with 316L stainless steel; Non-isolated differential pressure sensor
for clean, dry, non-corrosive gas applications
User-selectable automatic shutoff. Programmable for Disable, 10, 20, 30, 45, 60 minutes.
Leak test function lets you view Min/Max pressure values and calculates leak rate per min-
ute in pressure units.
Record up to 240 readings (automatically or manually collected) to reduce paperwork and
eld time. Recall your saved readings at any time.
100+ hours of battery life.
Minimum/maximum capture speed is equal to the selected damping rate.
Meriams M2 series can be recalibrated in the feld for zero, span, and linearity. Select a one-
point or ve-point calibration procedure. Enables users with accurate primary standards to
calibrate their devices locally if desired.
Selectable engineering units and scaling: H2O (select 4C, 20C, or 60F), PSI, mm Hg, Hg,
mBars, Bars, kPa, kg/cm2, cm H2O
CE Certifed
Catalog
Description Number Price
Lab Standard Smart Manometer M200LS- $0.00
Differential Pressure Models 0-28 H2O DN0028 1375.00
316L Stainless Steel, Brass, 0-200 H2O DN0200 1275.00
and Viton Wetted Parts 0-2000 H2O DN2000 1275.00
Gauge Pressure Models 0-30 PSI GI0030 1325.00
316L Stainless Steel 0-50 PSI GI0050 1325.00
Wetted Parts 0-100 PSI GI0100 1325.00
0-500 PSI GI0500 1325.00
Absolute Pressure Models 0-17.40 PSI AI0017 1575.00
316L Stainless Steel Wetted Parts 0-38.67 PSI AI0038 1575.00
Accessories
ABS Plastic Carrying Case with Manifold Cutout Z9A000069 83.00
MH10 Hydraulic Scissor Pump, 0-10000 PSI Z1066-10 999.00
(Includes hose, ttings, and carrying bag)
MVP600 Vac/Pressure Scissor Pump, 28 Hg400 PSI Z1066-6 548.00
(Includes hoses, ttings, carrying bag)
961P Pressure Pump Kit, 0-145 PSI B34686 376.00
(With integral variator, bleed valve, 1/8 NPTF conn)
961V Pressure Pump Kit, -650 mmHg B34700 376.00
(With integral variator, bleed valve, 1/8 NPTF conn)
316SS 3-Valve Manifold, Brass Tubing, 500 PSIG Z1089-1 240.00
316SS 3-Valve Manifold, 316SS Tubing, 3000 PSIG Z1089 500.00
All models include a protective platinum boot, four AA Alkaline batteries,
NIST Certicate of calibration, and a printed copy of the users manual
PRESSURE
CALIBRATORS
Need a manometer for wet/wet
differential pressure applications?
Meriams M200-DI is available in
pressure ranges from 01 to 0500
PSID with 0.05% full scale accuracy.
For uids compatible with 316L
stainless steel and Viton.
Call Lesman for pricing and delivery.
Learn more about Meriam
communicators, calibrators, and
testing devices online at Lesman.com
363
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Model Selection Guide
Catalog
Test Gauge Range* Number Price
Pump Only T-620 $332.00
Pump and 0-3000 PSI gauge T-623 380.00
*T-620 testers available
with optional ranges from
0-60 PSI to 0-1500 PSI. Call
for price and availability.
Specications
Operating Pressure: 3000 PSI max.
Accuracy: 0.5% gauge span. 1% full scale for 1,500 PSI and above
Materials: Wetted Parts: Aluminum, brass, stainless steel and Lexan; O-rings:
Buna-N; Test Fluid: Petroleum-based oils, hydraulic uids
Reservoir Capacity: 1 pint
Test Connection: 1/4 NPT, 24 long hose
Weight: 3.5 lbs.
PRESSURE
CALIBRATORS
Pressure Calibrators
Pneumatic Pressure Calibrator
Model Selection Guide
Description Catalog No. Price
Pressure calibrator, 0-160 H2O indicating gauge 44S369 $290.00
Pressure calibrator, 0-18 PSIG indicating gauge 44S390 290.00
Includes carrying case.
Hydraulic
Pressure Tester
Accurate to 1.5%
Check valve thumb screw to lock and relieve pressure
Gauge with squeeze bulb with thumb-adjusted valve for
one-hand operation
Portable
Electropneumatic
Calibrator
Model Selection Guide
Catalog Price
Description Number Each
Digital Electropneumatic Calibrator 65-2000-00-E $4272.00
Digital Electropneumatic Calibrator, Hand Pump 65-2000-II-E 5968.00
ABS Plastic Carrying Case FU 4876 395.00
Features
0.1% full-scale accuracy
Online calibration of pneu-
matic/electropneumatic
instruments
Operates on 115 volts or
rechargeable battery pack
Calibration traceable to NIST
24- or 48-volt output, with a
hand pump for test pressures
to 35 PSI
Easy to set up and connect
Measures absolute, gauge, or differential pressure, and current
or voltage at the ip of a switch; Switch selects readout in one of
four pressure units, 2 mA ranges, or voltage
Specications
Accuracy: 0.1% full scale; Resolution: 1 digit 0.03% to 0.005% full scale, de-
pendent upon range; Positional Sensitivity: Negligible
Readout: 4-1/2 digit LCD display, 7 segment, 3/8 high
Ranges: Pressure: -4 to 30 PSI or 3 to 15 PSI, -100 to 860 H2O, -8 to 65 Hg;
Current: Percent of 10-50 mA or 4-20 mA; Voltage: 0-200 volts DC
Maximum Differential Pressure: 65 PSI on P3 port with PSI on S port
Voltage Measurement Error: Less than 0.1% full scale
Power Supply: In: 115-volt AC or self-contained rechargeable NiCad battery
pack; Out: 24 V or 48 V capability. Fully charged batteries provide 6 hours
operation under maximum demand (48 V at 50 mA, 300 hours). Low bat-
tery power indicated by blinking display. Batteries can be recharged while
calibrator is operating.
Operating Temperature Range: 50 to 86 F (10 to 30 C). Maximum range
is 14 to 122 F (-10 to 50 C).
Air Supply: Maximum input pressure is 65 PSI. A pressure-relief valve protects
the transducer. Pressure connections are 1/8 female NPT.
Note: For use with noncorrosive gases. Not for use with liquids.
Replaces and
updates your
Wally Box!
Looking for high
precision test
gauges?
Call Lesman
for pricing and
availability.
364
V

0
3
.
2
0
1
0
Illinois, Indiana, Missouri, and Iowa
Phone: 800-953-7626 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
P
r
e
s
s
u
r
e

G
a
u
g
e
s
T
h
e
r
m
o
m
e
t
e
r
s
P
r
e
s
s
u
r
e

a
n
d


T
e
m
p
e
r
a
t
u
r
e

S
w
i
t
c
h
e
s
A
S
C
O

S
o
l
e
n
o
i
d

V
a
l
v
e
s
C
o
m
b
u
s
t
i
o
n

S
a
f
e
t
y

a
n
d

E
f

c
i
e
n
c
y
P
r
o
c
e
s
s

C
o
n
t
r
o
l

A
c
c
e
s
s
o
r
i
e
s
Backow Prevention Test Kits
Specications
Gauge Type: Diaphragm differential pressure
Dial Range: 0 to 15 PSID (0-100 kPa)
Accuracy: 0.2% PSID (descending)
Dial Size: 4.5 (with color-coded pointers)
Working Pressure: 200 PSIG
Construction Materials
Gauge: 830: Polysulfone body, with EPDM diaphragm and stainless steel
internals; 845: Engineered plastic body with EPDM diaphragm, brass 316SS
and engineered plastic internals
Valves: Soft-Seated Brass with black handles
Tubing and Fittings: Brass and Nylon
Hoses and End Fittings: 830: Nitrile jacket and liner with Schrader 1/4brass
coupler; 845: Buna-N jacket and liner and Schrader 1/4 brass coupler
Case: 830: Polyethylene; 845: Molded plastic
Hose Length: Three 5 long (color-coded), one 4 long clear bleed tube
Filters: Both test kits are protected with 90 micron brass flters to minimize
plugging with scale, sand, etc. Elements can be cleaned or replaced.
Adapter Fittings: Three sets of brass ttings provided for hookup to all
size devices.
Temperature Limits: Maximum 150F. Avoid freezing temperatures.
Special Note: Suitable for all known brands of backow prevention assem-
blies, test procedures, as recommended by ASSE, FCCC, HR-USC, AWWA, and
NEWWA, are provided in laminated plastic.
Case Dimensions (WDH): 830: 14.5 x 9 x 16; 845: 18.5 x 9 x 9.75
BACKFLOW
PREVENTION
Features Model 845 (Left)
Three different portable models, removable from case
Case has storage compartment for fttings and tools, and
room for additional accessories
Features Model 830 (Right)
Industry standard for three decades
Durable molded case with removable lid
High quality hinges and buckles
All test kits have
Soft seated needle valve with replaceable seats
Durable carrying case
Laminated test procedures
Line pressure gauge
Field-serviceable in-line hose flters
These test kits provide the capability for testing all brands of reduced
pressure prin ciple, pressure vacuum breaker, and double check valve
type backow prevention assemblies.
Instruction cards, laminated in clear plastic and stored in the lid of
the case, provide both plumbing schematics and test procedures as
specied in the Manual of Cross Connection Control published by the
Foundation for Cross Connection Control and Hydraulic Research and
the American Water Works Association. A certicate of calibration is
supplied with each test kit.
Model Selection Guide
Catalog
Description Number Price
Backow Prevention Test Kit 830 $950.00
Five-Valve Portable Test Kit 845-5 740.00
Three-Valve Portable Test Kit 845-3 740.00
Two-Valve Portable Test Kit 845-2 740.00
Bleed-Off Valve Assembly 830-0001 50.50
Vertical Tube Kit 830-0003 46.00
Test Cock Cleaning Tool 110694 78.00
Accessories Filter Assembly Adapter Kit (3-Pack) 109445 43.00
Replacement Filter Element Kit (6-Pack) 98008 32.00
Model 30 Replacement Hoses (3-Pack) 110645 85.00
Model 845 Replacement Hoses (3-Pack) 110646 85.00
Other replacement parts available. Call for pricing.