You are on page 1of 2

Smith Meter Rail and

Tank Truck Terminal Meters


We put you rst.
And keep you ahead.
SALES BULLETIN MEASUREMENT SOLUTIONS
MODEL SIZE
Inches
MAXIMUM FLOW RATE
GPM (L/min)
ST40/ST40-J 2 105 (400)
Genesis GSC2 2 150 (570)
ST75/ST75-J 2.5 265 (1,000)
ST75-SS 2.5 320 (1,200)
ST160/ST160-J 3 420 (1,600)
Genesis GSC3 3 500 (1,900)
E3 3 500 (1,900)
SF60/SF60-J 4 720 (2,750)
F4 4 720 (2,750)
PRIME 4 4 750 (2,850)
G6 6 1,200 (4,600)
PD METER TECHNOLOGY
Smith Meter PD meters have been the choice of terminal and
bulk plant operators for over 60 years. The unique rotary
vane design provides unsurpassed accuracy, long term
measurement stability and many years of maintenance free
performance. Its not uncommon for Smith Meter PD meters
to be in service for over 40 years.
The Genesis Series and PRIME 4 meters are innovative
designs that combine the benets of a turbine meter
and the performance stability of a traditional PD meter.
Genesis meters ofer a premium wide ow rate turn down
range and meet in particular the blending application needs.
PRIME 4 Genesis Series
E3
FEATURES
FMC Technologies unique Smith Meter rotary
vane design: the inlet/outlet nozzle design minimizes
pressure drop in the measurement chamber to
reduce slippage and maximize accuracy while its
streamlined ow path provides lowest system pressure
drop in class compared with any other system solution.
Models to meet various installation needs: all
models are available for horizontal installation and
selective models are available for angle or vertical
installation. PRIME 4 and Genesis meters can be installed
either horizontally or vertically.
Mechanical/electronic output: Genesis, PRIME 4,
and -J meters ofer integrated electronic output only.
All others are mechanical output meters with optional
external transmitter options. Genesis, PRIME 4, and
-J meters are packing gland free.
Typical applications: truck loading/unloading; rail
loading/unloading.
BENEFITS
High accuracy and stability to ensure certainty of
the delivered volume
Low pressure drop to maximize delivery rate
Long service life for trouble-free operation
www.fmctechnologies.com/measurementsolutions
2013 FMC Technologies. All rights reserved. SBSM007A1E Issue/Rev. 0.3 (3/13)
FMC Technologies
Measurement Solutions, Inc.
500 North Sam Houston Parkway West,
Suite 100
Houston, Texas 77067 USA
P:+1 281.260.2190
Germany Operation
Smith Meter GmbH
Regentstrasse 1
25474 Ellerbek, Germany
P:+49 4101.304.0
We put you rst.
And keep you ahead.
Smith Meter Barge and Marine
Terminal Metering Technologies
TURBINE METER TECHNOLOGY
Smith Meter Sentry

Series are conventional turbine meters and


ideal for low viscosity and high volume transfer applications.
Smith Meter Helical Type Turbine Meters like the MV Series
are engineered, built and tested to provide high accuracy
measurement over a wider range of product viscosity.
The MVTMs rugged design, titanium rotor and enhanced
pressure-balanced bearing system ensures highly stable
measurement and provides a long service life.
The Smith Meter Helical Turbine Meters are ideal for custody
transfer of all medium viscosity products with high long
lasting ow rates.
ULTRASONIC TECHNOLOGY
The non-intrusive design of the liquid ultrasonic ow meter
Smith Meter Ultra

Series has no moving parts to provide


a low maintenance measurement solution. It ofers a wide
dynamic ow range and wide viscosity application range
with low diferential pressure. The Ultra Series consists of
up to 8 path meter designs for complicated and custody
transfer applications and the Ultra
4
four path meter for other
high accuracy applications.
PD METER TECHNOLOGY
Smith Meter double case meter are line pressure
compensated and provide extreme low system pressure
drop, long life service and outstanding accuracy on higher
and varying viscosities.
APPLICATIONS
LPGs Gasoline Diesel fuel Jet fuel Heating oil
Crude oil Other blend components (ethanol)
BENEFITS
High accuracy and measurement stability provides
operational certainty each time
Metering element inserts for Turbine and PD Meters
for ease of service and reduced downtime
Ultra Series meters cause lower pressure drops than
turbine meter solutions and require less maintenance
Bidirectional measurement available for Sentry type
Turbine meters, Ultra Series and PD meters
FEATURES
Direct electronic output: all meters have direct pulse
output to interface with the Smith Meter Preset and Flow
Computer family of AccuLoad

, microLoad

and FMC
2

products or any other terminal loading/unloading system.
Real-time diagnostics: the world's unique Smith Meter
preamplier AccuLERT provides online diagnostics for
turbine meters. It senses and alarms when problematic
operating conditions occur such as bent blades, missing
blades and buttons, missing or damaged signals, swirl
situations, and cavitations. For further information see
bulletin SS02015.
WinScreen is an integrated and visual interface to the
Ultra Series electronics that is utilized during meter setup,
operation, and diagnostics. For further information see
bulletin SFLS003.
MODEL SIZE
(Inches)
FLOW RATE
per meter
Sentry

Series up to DN500 (20") up to 9,600 m
3
/h
MV Series up to DN400 (16") up to 4,300 m
3
/h
Ultra

Series up to DN1200 (48") up to 49,600 m


3
/h
Double Case PD up to DN400 (16") up to 2,000 m
3
/h
MVTM Turbine Meter
Ultra

Series
PD Meter