You are on page 1of 8

SMITH METER SKIDS AVAILABLE DIRECT

FROM FMC TECHNOLOGIES


Smith Meter equipment, from FMC Technologies, has long
been the standard for loading and blending ethanol or
biodiesel and other biofuels. Now terminal owners and
operators can have precision load rack skids direct from
FMC Technologies. The same engineering professionals
who design the world-renowned Smith Meter measuring
equipment have designed biofuels blending skids to precise
global specications.
Smith Meter Integrated
Biofuels Blending Skids
The Environmental Protection Agencys (EPA) demanding
renewable fuel standards (i.e., RFS2) require stringent uid
handling and measurement accuracy the kind of accuracy
Smith Meter equipment is known for. Your terminal operation
demands properly designed and tted skid-mounted equipment
to maximize your return-on-investment.
We put you rst.
And keep you ahead.
SALES BULLETIN MEASUREMENT SOLUTIONS
2
Experience: Over 80 years
of experience in terminal
applications worldwide;
more than any other supplier
Worldwide sales and service:
Local support before and after
the sale
The right meter: Smith Meter
Positive Displacement and
Turbine Meters
Accessories: Mechanical
or electronic controllers,
control valves, temperature
compensators, transmitters,
strainers and air eliminators
Worldwide approvals: Our
equipment meets (or exceeds)
most weights and measures,
electrical and mechanical design
code requirements worldwide
FMC Technologies provides cost efective
system integration with a exible approach
and open architecture products such as
the Smith Meter AccuLoad preset. Using
only FMC Technologies equipment and
electronics ensures custody transfer
accuracy and performance.
FMC Technologies
is the leading
supplier for terminal
measurement
equipment with:
3
BENEFITS
Standard pre-packaged skids support up to four
blend streams
Standard blend rates range from 2% to 25% at a
typical loading rate of 600 GPM
Small skid footprint is suitable for new or retrot
upgrade installations
Standard skids accommodate a variety of
blending techniques including ratio, sidestream,
and wild-stream blending
Pre-packaged skids reduce cost and terminal
downtime
Best-in-industry measurement expertise
Full support of FMC Technologies global customer
distribution and eld service network
Tank Truck Loading Rack Solutions
for Ethanol or Biodiesel Blending
PROVEN, RELIABLE, ACCURATE
FMC Technologies integrated biofuels blending modules meet
the needs of a convenient, turnkey solution complete with
state-of-the-art metering technology and supported with a
comprehensive load rack product portfolio.
We incorporate the latest metering technology for positive
displacement and turbine meters, along with digital ow
control valves to provide optimum measurement accuracy.
Our skids integrate into existing blending-capable presets,
such as the Smith Meter AccuLoad III. These blending presets
can quickly be recongured on-site, from straight product
loading to sidestream or ratio blend loading, resulting in
highly accurate biofuel blends.
At FMC Technologies, our core business is custody transfer
measurement and ow control. Our expertise in custody
transfer measurement, combined with our knowledge of
loading rack operating conditions, make us the best
choice for designing and building
biofuels blending systems
for your business. Choose
FMC Technologies to
build your next
biofuels blending
skid, already
designed to meet
your specic needs.
Smith Meter Model 210
RP Digital Flow Control Valve
Smith Meter E-Type Strainer
Smith Meter Genesis Positive
Displacement Meter
The same engineering professionals who design
the world-renowned Smith Meter measuring
equipment also design biofuels skids to precise
global specications. Why settle for less?
4
BLENDING SYSTEM COMPONENTS
2" Metering streams consisting of:
- PD or turbine meters
- Digital control valves
- Pressure gauges
- Prover takeofs with cam and groove tting and dust cap
- Optional outlet isolation valve (standard on single stream)
4" inlet header with strainer and isolation valve
Thermal relief port
RTDs and calibration test ports
- Note: 2" Genesis PD meter available with integral RTD
FABRICATION SPECIFICATIONS
150 lb ANSI rating
Pipe welding per ASME B31.3
10% x-ray examination per ASME B31.3
Hydro test 1.5x for 1 hour
Electrical rigid conduit, ttings and wiring from meter,
valve and temperature probe to AC/DC junction boxes
per NFPA 70: NEC for hazardous (classied) locations
Post weld heat treat option (recommended for ethanol service)
Powder coated structural steel and piping
APPLICATIONS
1 through 4 position vertical designs using 2" PD meter
- Flow Range: 3 to 150 GPM, 12 to 567 LPM
- Target Applications: Ethanol E10 (future E15) and
Biodiesel B2 to B20
1 through 4 position vertical design using 1.5" turbine meters
- Flow Range: 13 to 130 GPM, 50 to 500 LPM
- Target Applications: Ethanol E10 (future E15)
1 through 4 position vertical designs using 2" turbine meters
- Flow Range: 25 to 250 GPM, 95 to 950 LPM
- Target Applications: Ethanol Blending
Smith Meter Genesis

Series
PD Meters
Smith Meter Guardsman

L Series
Turbine Meters
Smith Meter 200 Series
Digital Control Valves
Smith Meter Strainers and
Line Accessories
Smith Meter Product Ofering
5
Blending Methods
Typically the term ratio blending is used where the biofuel
stream is mixed with the main product stream downstream
of the main product meter. One electronic controller device
manages all ow streams. (Illustrated is a three stream
metering system). With this blending method, the biofuel
stream is considered part of the custody transfer metering.
The main advantage for Ratio Blending is that all nal
components are individually and accurately measured,
thus enabling correct inventory reconciliation. This method
provides the most accurate nal custody transfer volume
information.
Side stream blending, an alternative to ratio blending, is
where the biofuel meter stream is mixed upstream of the
main product stream delivery meter, which measures the
total of the delivered blend product. (Illustrated is a three
stream metering system). The volumes of each product are
derived by subtracting the secondary component total from
the delivery total. These volumes are then available for
inventory reconciliation. Thus, the accuracy of this method
is dependent on the precision of the product meter at each
individual arm. The biofuel stream must be pumped into the
main product stream at a higher pressure in order to get the
product into the main line. This alternative method aids in
the mixing process as the blended product passes through
a meter that mechanically mixes,or integrates the fuel.
RATIO BLENDING
SIDE STREAM BLENDING
Load Rack
Smith Meter
ccuLoad III
Blending Presets
Gasoline
Gasoline
Gasoline
Ethanol
Biofuel Blending Skid
Smith Meter
AccuLoad III
Blending Presets
Diesel
Load Rack
Diesel
Diesel
Biodiesel
(B100)
Biofuel Blending Skid
6
General Congurations
A
B1
E
B2
D
C
F(2)
J
G
M
L
K
H
N
O
L
M
P
F(1)
T
S Q
R
U
A
B1
E
B2
D
C
F(2)
J
G
M
L
K
H
N
O
L
M
P
F(1)
T
S Q
R
U
BIOFUEL SKID OVERALL DIMENSIONS
Inches (mm)
2" Genesis
PD Meter
2" Turbine
Meter
1.5" Turbine
Meter
A 78.9" (2,004)
B1 Option
(Master Meter)
15.0" (380)
B2 Option
(Prover Tank)
50.3" (1,276) 75.3" (1,913) 67.2" (1,707)
C 76.0" (1,929) 101.0" (2,566) 92.9" (2,359)
D 83.1" (2,110) 108.1" (2,747) 100.0" (2,540)
E 4.5" (115)
F1
2 Stream
Manifold
4.1" (105)
F2
4 Stream
Manifold
16.4" (416)
G 16.4" (416)
H 32.7" (831)
J 30.4" (771)
K 60.7" (1,542)
L 10.2" (259)
M 20.4" (517)
N 24.6" (625)
O 50.0" (1,269)
P 14.5" (367)
Q 36.0" (914)
R 46.0" (1,168)
S 32.0" (813)
T 42.0" (1,067)
U 0.9" (22)
Prover Take Ofs
MM Option
A
B1
E
B2
D
C
F(2)
J
G
M
L
K
H
N
O
L
M
P
F(1)
T
S Q
R
U
Prover Take Of
PT Option
A
B1
E
B2
D
C
F(2)
J
G
M
L
K
H
N
O
L
M
P
F(1)
T
S Q
R
U
Bottom View
Top View 4 Stream Manifold Top View 2 Stream Manifold
7
Catalog Code
1 2 3 4 5 6 7 8 9 10 11 12
BFS 4 PD 21R B PT BV 16 G N Y N
1
4 Stream Manifold; Unused Streams Blind Flanged Of.
2
2 Stream Manifold; Unused Streams Blind Flanged Of.
Position 1: Type of Equipment
BFS - Biofuel Skid
Position 2: Number of Metering Streams
1 - One Stream
1

2 - Two Streams
1

3 - Three Streams
1

4 - Four Streams
1

5 - One Stream
2

6 - Two Stream
2
Position 3: Meter Type/Size
PD - 2" Genesis PD Meter
T1 - 1.5" Turbine Meter
T2 - 2" Turbine Meter
Position 4: Control Valve Type
21R - 2" 210 Reduced Port Control Valve
215B - 2" 215 V-Ball Valve
Position 5: Product Service
(Elastomer Compatibility)
B - Biodiesel
E - Ethanol
O - Other
Position 6: Prover Takeofs
PT - Volumetric Prover Tank
MM - Master Meter/SVP
Position 7: Meter Stream Isolation Valve Type
BV - 2" Ball Valve
DB - 2" Double Block and Bleed
Position 8: Electrical Power
15 - 110 VAC @ 50 Hz
16 - 120 VAC @ 60 Hz
25 - 220 VAC @ 50 Hz
26 - 240 VAC @ 60 Hz
Position 9: Temperature Probes
N - None
S - One per Meter Stream
H - One in Common Inlet Header
G - 2" Genesis PD Meter Probe
Position 10: Outlet Valve
N - None
S - One per Meter Stream
Position 11: Post Weld Heat Treat (PWHT)*
N - No
Y - Yes
* Recommended for Ethanol Service
Position 12: miniBlend.net
N - No
S - One per Meter Stream
The following guide denes the correct biofuels blending skid for a given application and the respective catalog code. This code
is part of the ordering information and should be included on the purchase order.
www.fmctechnologies.com/measurementsolutions
2013 FMC Technologies. All rights reserved. SB0A012 Issue/Rev. 0.1 (3/13)
FMC Technologies
Measurement Solutions, Inc.
500 North Sam Houston Parkway West,
Suite 100
Houston, Texas 77067 USA
P:+1 281.260.2190
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
We put you rst.
And keep you ahead.
REFERENCE PUBLICATIONS
The following Smith Meter Product Literature can be obtained from FMC Technologies
Measurement Solutions, Inc. Literature Fulllment at measurement.fulllment@fmcti.com
or online at www.fmctechnologies.com/measurementsolutions. When requesting literature
from Literature Fulllment, please reference the appropriate bulletin number and title.
REFERENCE PUBLICATIONS FOR EUROPEAN
MARKET REGULATIONS
Contact our Ellerbek, Germany Operation at +49 4101 3040
or email info.ellerbek@fmcti.com for systems that are
designed requiring European Market regulations such as the
Pressure Equipment Directive 97/23/EC (PED); the Directive
94/9/EC for Equipment and Protective Systems intended for
use in potentially explosive atmospheres (ATEX); National
Weights & Measures directives and especially the new
European Measurement Instrumentation Directive 2004/22/EG
(MID) (now legally required in the European Community).
Bulletin No. Title
SB01011 Smith Meter Genesis Series PD Meter Sales Bulletin
SS01060 2" and 3" Smith Meter Genesis Series PD Meter Specications
SS02003 1" to 4" Smith Meter Guardsman LB, LJ and LSJ Series Turbine Meter Specications
SS03009 Model 210 Digital Electro-Hydraulic Set-Stop Control Valve Specications
SS03043 Model 215B V-Ball Valve Specications
TP0A015 Renewable Fuels Blending Solutions Technical Paper